This Section describes the CT Image Module. This Module contains all Attributes that are specific to CT images.
The table in this Section contains IOD Attributes that describe CT images.
Table C.8-3. CT Image Module Attributes
Image identification characteristics. See Section C.8.2.1.1.1 for specialization. |
|||
Number of samples (planes) in this image. See Section C.8.2.1.1.2 for specialization. |
|||
Specifies the intended interpretation of the pixel data. See Section C.8.2.1.1.3 for specialization. |
|||
Number of bits allocated for each pixel sample. Each sample shall have the same number of bits allocated. See Section C.8.2.1.1.4 for specialization. |
|||
Number of bits stored for each pixel sample. Each sample shall have the same number of bits stored. See Section C.8.2.1.1.5 for specialization. |
|||
Most significant bit for pixel sample data. Each sample shall have the same high bit. See Section C.8.2.1.1.6 for specialization. |
|||
The value b in relationship between stored values (SV) and the output units. If Image Type (0008,0008) Value 1 is ORIGINAL and Value 3 is not LOCALIZER, output units shall be Hounsfield Units (HU). |
|||
m in the equation specified in Rescale Intercept (0028,1052). |
|||
Specifies the output units of Rescale Slope (0028,1053) and Rescale Intercept (0028,1052). See Section C.11.1.1.2 for Defined Terms and further explanation. Required if the Rescale Type is not HU (Hounsfield Units). May be present otherwise. |
|||
A number identifying the single continuous gathering of data over a period of time that resulted in this image |
|||
The diameter in mm of the region over which data were collected |
|||
The x, y, and z coordinates (in the patient coordinate system) in mm of the center of the region in which data were collected. See Section C.8.15.3.6.1. |
|||
Diameter in mm of the region from within which data were used in creating the reconstruction of the image. Data may exist outside this region and portions of the patient may exist outside this region. |
|||
The x, y, and z coordinates (in the patient coordinate system) of the reconstruction center target point as used for reconstruction in mm. See Section C.8.15.3.6.1. |
|||
Distance in mm from source to isocenter (center of field of view). |
|||
Nominal angle of tilt in degrees of the scanning gantry. Not intended for mathematical computations. |
|||
The distance in mm of the top of the patient table to the center of rotation; below the center is positive. |
|||
Direction of rotation of the source when relevant, about nearest principal axis of equipment. |
|||
Time of x-ray exposure in msec. If Acquisition Type (0018,9302) equals SPIRAL, the value of this attribute shall be Revolution Time (0018,9305) divided by the Spiral Pitch Factor (0018,9311). See Section C.8.15.3.8.1 and Section C.8.15.3.2.1. |
|||
The exposure expressed in mAs, for example calculated from Exposure Time and X-Ray Tube Current. |
|||
The exposure expressed in µAs, for example calculated from Exposure Time and X-Ray Tube Current. |
|||
Size of the focal spot in mm. For devices with variable focal spot or multiple focal spots, small dimension followed by large dimension. |
|||
A label describing the convolution kernel or algorithm used to reconstruct the data |
|||
The time in seconds of a complete revolution of the source around the gantry orbit. |
|||
The width of the total collimation (in mm) over the area of active x-ray detection. |
|||
The distance in mm that the table moves in one second during the gathering of data that resulted in this image. |
|||
Motion of the table (in mm) during a complete revolution of the source around the gantry orbit. |
|||
Ratio of the Table Feed per Rotation (0018,9310) to the Total Collimation Width (0018,9307). |
|||
A label describing the type of exposure modulation used for the purpose of limiting the dose. |
|||
A percent value of dose saving due to the use of Exposure Modulation Type (0018,9323). A negative percent value of dose savings reflects an increase of exposure. |
|||
Computed Tomography Dose Index (CTDIvol), in mGy according to IEC 60601-2-44, Ed.2.1 (Clause 29.1.103.4), The Volume CTDIvol. It describes the average dose for this image for the selected CT conditions of operation. |
|||
The type of phantom used for CTDI measurement according to IEC 60601-2-44. |
|||
Defined CID 4052 “Phantom Devices”. |
|||
Include Table 10-7 “General Anatomy Optional Macro Attributes” |
Defined CID for the Anatomic Region Sequence is CID 4030 “CT, MR and PET Anatomy Imaged”. |
||
Include Table 10-25 “Optional View and Slice Progression Direction Macro Attributes” |
|||
The calibration factor for the calcium mass score. These factors incorporate the effects of See Section C.8.2.1.1.7. |
|||
The calibration factors for the calcium mass score of the device. These factors incorporate the effects of This a multi-value attribute, the first value specifies the mass factor for a small patient size, the second value for a medium patient size and the third value for a large patient size. See Section C.8.2.1.1.7. |
|||
The weighting factor of the data from the primary source in a multiple energy composition image. This factor incorporates the effects of Required if one Derivation Code Sequence (0008,9215) Item value is (113097, DCM, "Multi-energy proportional weighting"). May be present otherwise. |
|||
Contains the attributes describing additional acquisition parameters beyond the primary source in a multiple X-Ray source system or a multi-energy acquisition. The primary X-Ray source is specified in other attributes of this module. |
|||
The diameter in mm of the region over which data were collected. |
|||
The exposure expressed in milliampere seconds, for example calculated from exposure time and X-Ray tube current. |
|||
The weighting factor of the data from this additional source in a multiple energy composition image. This factor incorporates the effects of Required if one Derivation Code Sequence (0008,9215) Item value is (113097, DCM, "Multi-energy proportional weighting"). May be present otherwise. |
|||
Isocenter coordinates (x,y,z), in mm. Specifies the location of the machine isocenter in the patient-based coordinate system associated with the Frame of Reference. It allows transformation from the equipment-based coordinate system to the patient-based coordinate system. |
|||
Include Table 10-27 “RT Equipment Correlation Macro Attributes Description” |
See Section C.7.6.3.1.2 for definition of these terms.
The calibration factors for the Calcium Scoring Mass Factor Patient (0018,9351) and Calcium Scoring Mass Factor Device (0018,9352) attributes are defined by the International Consortium for Multi-Detector CT Evaluation of Coronary Calcium, see McCollough, C.H. "A multi-institutional, multi-manufacturer, international standard for the quantification of coronary artery calcium using cardiac CT".