    <description value="Transitive closure of CID 3611 PressureMeasurement"/>
    <copyright value="© 2026 NEMA"/>
    <compose>
        <include>
            <system value="http://dicom.nema.org/resources/ontology/DCM"/>
            <concept>
                <code value="122208"/>
                <display value="x-descent pressure"/>
            </concept>
            <concept>
                <code value="122209"/>
                <display value="y-descent pressure"/>
            </concept>
            <concept>
                <code value="122191"/>
                <display value="Ventricular End Diastolic pressure"/>
            </concept>
            <concept>
                <code value="109016"/>
                <display value="A wave peak pressure"/>
            </concept>
            <concept>
                <code value="122199"/>
                <display value="Pressure at dp/dt max"/>
            </concept>
            <concept>
                <code value="109034"/>
                <display value="V wave peak pressure"/>
            </concept>
            <concept>
                <code value="122210"/>
                <display value="z-point pressure"/>
            </concept>
            <concept>
                <code value="122197"/>
                <display value="Gradient pressure, average"/>
            </concept>
            <concept>
                <code value="122198"/>
                <display value="Gradient pressure, peak"/>
            </concept>
            <concept>
                <code value="122196"/>
                <display value="C wave pressure"/>
            </concept>
        </include>
        <include>
            <system value="http://loinc.org"/>
            <concept>
                <code value="8462-4"/>
                <display value="Intravascular diastolic blood pressure"/>
            </concept>
            <concept>
                <code value="8480-6"/>
                <display value="Intravascular Systolic Blood pressure"/>
            </concept>
        </include>
        <include>
            <system value="http://snomed.info/sct"/>
            <concept>
                <code value="314453003"/>
                <display value="Average diastolic blood pressure"/>
            </concept>
            <concept>
                <code value="314451001"/>
                <display value="Minimum diastolic blood pressure"/>
            </concept>
            <concept>
                <code value="314440001"/>
                <display value="Average systolic blood pressure"/>
            </concept>
            <concept>
                <code value="314439003"/>
                <display value="Maximum systolic blood pressure"/>
            </concept>
            <concept>
                <code value="6797001"/>
                <display value="Mean blood pressure"/>
            </concept>
        </include>
        <include>
            <system value="http://snomed.info/srt"/>
            <concept>
                <code value="F-00E22"/>
                <display value="Average diastolic blood pressure"/>
            </concept>
            <concept>
                <code value="F-00E11"/>
                <display value="Maximum systolic blood pressure"/>
            </concept>
            <concept>
                <code value="F-00E14"/>
                <display value="Average systolic blood pressure"/>
            </concept>
            <concept>
                <code value="F-00E1F"/>
                <display value="Minimum diastolic blood pressure"/>
            </concept>
            <concept>
                <code value="F-31150"/>
                <display value="Mean blood pressure"/>
            </concept>
        </include>
    </compose>