
{
    "resourceType":"ValueSet",
    "id":"dicom-cid-6301-ProstateSectorAnatomyFromPIRADSv2",
    "url":"http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_6301.html",
    "identifier":[
        {
            "system":"urn:ietf:rfc:3986",
            "value":"urn:oid:1.2.840.10008.6.1.1139"
        }
    ],
    "version":"20161106",
    "name":"ProstateSectorAnatomyfromPIRADSv2",
    "status":"active",
    "experimental":false,
    "date":"2026-09-19",
    "publisher":"NEMA MITA DICOM",
    "description":"Transitive closure of CID 6301 ProstateSectorAnatomyfromPIRADSv2",
    "copyright":"© 2026 NEMA",
    "compose":{
        "include":[
            {
                "system":"http://snomed.info/sct",
                "concept":[
                    {
                        "code":"717027004",
                        "display":"Male external urethral sphincter"
                    },
                    {
                        "code":"716926002",
                        "display":"Right apical anterior fibromuscular stroma of prostate"
                    },
                    {
                        "code":"716941002",
                        "display":"Left posteromedial apical peripheral zone of prostate"
                    },
                    {
                        "code":"716922000",
                        "display":"Left posterolateral middle peripheral zone of prostate"
                    },
                    {
                        "code":"716931000",
                        "display":"Left anterior apical transition zone of prostate"
                    },
                    {
                        "code":"716897000",
                        "display":"Left anterior basal transition zone of prostate"
                    },
                    {
                        "code":"716906001",
                        "display":"Right posterolateral basal peripheral zone of prostate"
                    },
                    {
                        "code":"716916009",
                        "display":"Left posterior middle transition zone of prostate"
                    },
                    {
                        "code":"716893001",
                        "display":"Left basal anterior fibromuscular stroma of prostate"
                    },
                    {
                        "code":"716939003",
                        "display":"Left posterolateral apical peripheral zone of prostate"
                    },
                    {
                        "code":"74308000",
                        "display":"Right seminal vesicle"
                    },
                    {
                        "code":"716923005",
                        "display":"Right posteromedial middle peripheral zone of prostate"
                    },
                    {
                        "code":"716927006",
                        "display":"Left apical anterior fibromuscular stroma of prostate"
                    },
                    {
                        "code":"716940001",
                        "display":"Right posteromedial apical peripheral zone of prostate"
                    },
                    {
                        "code":"716907005",
                        "display":"Left posterolateral basal peripheral zone of prostate"
                    },
                    {
                        "code":"716938006",
                        "display":"Right posterolateral apical peripheral zone of prostate"
                    },
                    {
                        "code":"716898005",
                        "display":"Right posterior basal transition zone of prostate"
                    },
                    {
                        "code":"716930004",
                        "display":"Right anterior apical transition zone of prostate"
                    },
                    {
                        "code":"716920008",
                        "display":"Left anterior middle peripheral zone of prostate"
                    },
                    {
                        "code":"716913001",
                        "display":"Right anterior middle transition zone of prostate"
                    },
                    {
                        "code":"716901006",
                        "display":"Central zone of left half prostate"
                    },
                    {
                        "code":"716924004",
                        "display":"Left posteromedial middle peripheral zone of prostate"
                    },
                    {
                        "code":"716892006",
                        "display":"Right basal anterior fibromuscular stroma of prostate"
                    },
                    {
                        "code":"716896009",
                        "display":"Right anterior basal transition zone of prostate"
                    },
                    {
                        "code":"716933002",
                        "display":"Left posterior apical transition zone of prostate"
                    },
                    {
                        "code":"716914007",
                        "display":"Left anterior middle transition zone of prostate"
                    },
                    {
                        "code":"716899002",
                        "display":"Left posterior basal transition zone of prostate"
                    },
                    {
                        "code":"716904003",
                        "display":"Right anterior basal peripheral zone of prostate"
                    },
                    {
                        "code":"716910003",
                        "display":"Left middle anterior fibromuscular stroma of prostate"
                    },
                    {
                        "code":"716937001",
                        "display":"Left anterior apical peripheral zone of prostate"
                    },
                    {
                        "code":"716900007",
                        "display":"Central zone of right half prostate"
                    },
                    {
                        "code":"716919002",
                        "display":"Right anterior middle peripheral zone of prostate"
                    },
                    {
                        "code":"716921007",
                        "display":"Right posterolateral middle peripheral zone of prostate"
                    },
                    {
                        "code":"42320003",
                        "display":"Left seminal vesicle"
                    },
                    {
                        "code":"716936005",
                        "display":"Right anterior apical peripheral zone of prostate"
                    },
                    {
                        "code":"716905002",
                        "display":"Left anterior basal peripheral zone of prostate"
                    },
                    {
                        "code":"716909008",
                        "display":"Right middle anterior fibromuscular stroma of prostate"
                    },
                    {
                        "code":"716915008",
                        "display":"Right posterior middle transition zone of prostate"
                    },
                    {
                        "code":"716932007",
                        "display":"Right posterior apical transition zone of prostate"
                    }
                ]
            },
            {
                "system":"http://snomed.info/srt",
                "concept":[
                    {
                        "code":"T-93010",
                        "display":"Right seminal vesicle"
                    },
                    {
                        "code":"R-FFFCD",
                        "display":"Right anterior middle peripheral zone of prostate"
                    },
                    {
                        "code":"R0-00025",
                        "display":"Left anterior apical peripheral zone of prostate"
                    },
                    {
                        "code":"R-FFFD0",
                        "display":"Central zone of right half prostate"
                    },
                    {
                        "code":"R0-00027",
                        "display":"Left middle anterior fibromuscular stroma of prostate"
                    },
                    {
                        "code":"R-FFFD9",
                        "display":"Male external urethral sphincter"
                    },
                    {
                        "code":"R-FFFD4",
                        "display":"Right posteromedial middle peripheral zone of prostate"
                    },
                    {
                        "code":"R-FFFD6",
                        "display":"Left anterior basal transition zone of prostate"
                    },
                    {
                        "code":"R-FFFDC",
                        "display":"Left basal anterior fibromuscular stroma of prostate"
                    },
                    {
                        "code":"R0-0001E",
                        "display":"Right posterolateral basal peripheral zone of prostate"
                    },
                    {
                        "code":"T-93020",
                        "display":"Left seminal vesicle"
                    },
                    {
                        "code":"R-FFFDD",
                        "display":"Left posterolateral apical peripheral zone of prostate"
                    },
                    {
                        "code":"R-FFFDF",
                        "display":"Left apical anterior fibromuscular stroma of prostate"
                    },
                    {
                        "code":"R-FFFE2",
                        "display":"Right anterior basal peripheral zone of prostate"
                    },
                    {
                        "code":"R-FFFE9",
                        "display":"Left posterolateral middle peripheral zone of prostate"
                    },
                    {
                        "code":"R-FFFE5",
                        "display":"Left anterior apical transition zone of prostate"
                    },
                    {
                        "code":"R-FFFEA",
                        "display":"Right posteromedial apical peripheral zone of prostate"
                    },
                    {
                        "code":"R-FFFAB",
                        "display":"Left posterior middle transition zone of prostate"
                    },
                    {
                        "code":"R0-00001",
                        "display":"Left anterior basal peripheral zone of prostate"
                    },
                    {
                        "code":"R0-00000",
                        "display":"Right anterior basal transition zone of prostate"
                    },
                    {
                        "code":"R0-00003",
                        "display":"Right anterior apical peripheral zone of prostate"
                    },
                    {
                        "code":"R-FFFF3",
                        "display":"Right posterior apical transition zone of prostate"
                    },
                    {
                        "code":"R-FFFF2",
                        "display":"Right basal anterior fibromuscular stroma of prostate"
                    },
                    {
                        "code":"R-FFFB1",
                        "display":"Right posterior basal transition zone of prostate"
                    },
                    {
                        "code":"R-FFFB0",
                        "display":"Left anterior middle peripheral zone of prostate"
                    },
                    {
                        "code":"R-FFFF4",
                        "display":"Right anterior middle transition zone of prostate"
                    },
                    {
                        "code":"R0-00004",
                        "display":"Right middle anterior fibromuscular stroma of prostate"
                    },
                    {
                        "code":"R0-00006",
                        "display":"Right anterior apical transition zone of prostate"
                    },
                    {
                        "code":"R-FFFB7",
                        "display":"Left posterior basal transition zone of prostate"
                    },
                    {
                        "code":"R-FFFB5",
                        "display":"Left posteromedial middle peripheral zone of prostate"
                    },
                    {
                        "code":"R-FFFFC",
                        "display":"Central zone of left half prostate"
                    },
                    {
                        "code":"R-FFFFD",
                        "display":"Right apical anterior fibromuscular stroma of prostate"
                    },
                    {
                        "code":"R0-00014",
                        "display":"Left posterior apical transition zone of prostate"
                    },
                    {
                        "code":"R-FFFC0",
                        "display":"Right posterolateral apical peripheral zone of prostate"
                    },
                    {
                        "code":"R0-00013",
                        "display":"Left anterior middle transition zone of prostate"
                    },
                    {
                        "code":"R-FFFC2",
                        "display":"Left posterolateral basal peripheral zone of prostate"
                    },
                    {
                        "code":"R-FFFC9",
                        "display":"Right posterior middle transition zone of prostate"
                    },
                    {
                        "code":"R0-0000C",
                        "display":"Right posterolateral middle peripheral zone of prostate"
                    },
                    {
                        "code":"R0-0000B",
                        "display":"Left posteromedial apical peripheral zone of prostate"
                    }
                ]
            }
        ]
    }
}