    "resourceType":"ValueSet",
    "id":"dicom-cid-3700-CathDiagnosis",
    "url":"http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_3700.html",
    "identifier":[
        {
            "system":"urn:ietf:rfc:3986",
            "value":"urn:oid:1.2.840.10008.6.1.203"
        }
    ],
    "version":"20220922",
    "name":"CathDiagnosis",
    "status":"active",
    "experimental":false,
    "date":"2026-09-19",
    "publisher":"NEMA MITA DICOM",
    "description":"Transitive closure of CID 3700 CathDiagnosis",
    "copyright":"© 2026 NEMA",
    "compose":{
        "include":[
            {
                "system":"http://snomed.info/sct",
                "concept":[
                    {
                        "code":"308546005",
                        "display":"Aortic dissection"
                    },
                    {
                        "code":"71908006",
                        "display":"Ventricular fibrillation"
                    },
                    {
                        "code":"371809004",
                        "display":"Recurrent angina Post-Stent"
                    },
                    {
                        "code":"35304003",
                        "display":"Pericardial tamponade"
                    },
                    {
                        "code":"48724000",
                        "display":"Mitral regurgitation"
                    },
                    {
                        "code":"70995007",
                        "display":"Pulmonary hypertension"
                    },
                    {
                        "code":"19242006",
                        "display":"Pulmonary edema"
                    },
                    {
                        "code":"79619009",
                        "display":"Mitral stenosis"
                    },
                    {
                        "code":"70142008",
                        "display":"Atrial septal defect"
                    },
                    {
                        "code":"314116003",
                        "display":"Post-infarction angina"
                    },
                    {
                        "code":"409712001",
                        "display":"Mitral valve prolapse"
                    },
                    {
                        "code":"233819005",
                        "display":"Stable Angina"
                    },
                    {
                        "code":"13213009",
                        "display":"heart disease, congenital"
                    },
                    {
                        "code":"371811008",
                        "display":"Recurrent angina Post-Rotational Atherectomy"
                    },
                    {
                        "code":"67362008",
                        "display":"Aortic aneurysm"
                    },
                    {
                        "code":"194983005",
                        "display":"Aortic insufficiency"
                    },
                    {
                        "code":"49436004",
                        "display":"Atrial fibrillation"
                    },
                    {
                        "code":"20721001",
                        "display":"Tricuspid valve disease"
                    },
                    {
                        "code":"371812001",
                        "display":"Recurrent angina Post-DCA"
                    },
                    {
                        "code":"25569003",
                        "display":"Ventricular tachycardia"
                    },
                    {
                        "code":"399020009",
                        "display":"Congestive cardiomyopathy"
                    },
                    {
                        "code":"53741008",
                        "display":"Coronary artery disease"
                    },
                    {
                        "code":"57054005",
                        "display":"Acute myocardial infarction"
                    },
                    {
                        "code":"233823002",
                        "display":"Silent ischemia"
                    },
                    {
                        "code":"45227007",
                        "display":"Hypertrophic obstructive cardiomyopathy"
                    },
                    {
                        "code":"42343007",
                        "display":"Congestive heart failure"
                    },
                    {
                        "code":"60573004",
                        "display":"Aortic stenosis"
                    },
                    {
                        "code":"11851006",
                        "display":"Mitral valve disease"
                    },
                    {
                        "code":"373116009",
                        "display":"Acute mitral regurgitation"
                    },
                    {
                        "code":"698247007",
                        "display":"Arrhythmia"
                    },
                    {
                        "code":"8722008",
                        "display":"Aortic valve disease"
                    },
                    {
                        "code":"4557003",
                        "display":"Unstable Angina, Progressive Angina"
                    },
                    {
                        "code":"55855009",
                        "display":"Pericardial disease"
                    },
                    {
                        "code":"371817007",
                        "display":"Acute ventricular septal rupture"
                    },
                    {
                        "code":"102589003",
                        "display":"Atypical chest pain"
                    },
                    {
                        "code":"76267008",
                        "display":"Pulmonic valve disease"
                    },
                    {
                        "code":"89138009",
                        "display":"cardiogenic shock"
                    },
                    {
                        "code":"50920009",
                        "display":"Myocarditis"
                    },
                    {
                        "code":"64715009",
                        "display":"Hypertensive heart disease"
                    },
                    {
                        "code":"371808007",
                        "display":"Recurrent angina Post-PTCA"
                    },
                    {
                        "code":"30288003",
                        "display":"Ventricular septal defect"
                    },
                    {
                        "code":"90828009",
                        "display":"Restrictive cardiomyopathy"
                    },
                    {
                        "code":"371824008",
                        "display":"s/p MI positive stress for ischemia"
                    },
                    {
                        "code":"87343002",
                        "display":"Atypical Angina, Variant Angina"
                    },
                    {
                        "code":"73774007",
                        "display":"Subacute bacterial endocarditis"
                    },
                    {
                        "code":"111287006",
                        "display":"Tricuspid regurgitation"
                    },
                    {
                        "code":"371810009",
                        "display":"Recurrent angina Post-CABG"
                    },
                    {
                        "code":"85598007",
                        "display":"Constrictive pericarditis"
                    }
                ]
            },
            {
                "system":"http://snomed.info/srt",
                "concept":[
                    {
                        "code":"D3-15100",
                        "display":"Acute myocardial infarction"
                    },
                    {
                        "code":"D3-13040",
                        "display":"Coronary artery disease"
                    },
                    {
                        "code":"D3-40300",
                        "display":"Pulmonary hypertension"
                    },
                    {
                        "code":"D3-90000",
                        "display":"Pericardial disease"
                    },
                    {
                        "code":"R-00366",
                        "display":"Recurrent angina Post-Stent"
                    },
                    {
                        "code":"R-00365",
                        "display":"Recurrent angina Post-CABG"
                    },
                    {
                        "code":"R-00368",
                        "display":"Recurrent angina Post-PTCA"
                    },
                    {
                        "code":"R-00367",
                        "display":"Recurrent angina Post-DCA"
                    },
                    {
                        "code":"D3-31700",
                        "display":"Ventricular tachycardia"
                    },
                    {
                        "code":"D4-31000",
                        "display":"heart disease, congenital"
                    },
                    {
                        "code":"R-00369",
                        "display":"Recurrent angina Post-Rotational Atherectomy"
                    },
                    {
                        "code":"D3-23000",
                        "display":"Hypertrophic obstructive cardiomyopathy"
                    },
                    {
                        "code":"D3-29025",
                        "display":"Aortic insufficiency"
                    },
                    {
                        "code":"D3-00200",
                        "display":"cardiogenic shock"
                    },
                    {
                        "code":"D3-02500",
                        "display":"Hypertensive heart disease"
                    },
                    {
                        "code":"D3-1081C",
                        "display":"Mitral valve prolapse"
                    },
                    {
                        "code":"D3-29040",
                        "display":"Tricuspid valve disease"
                    },
                    {
                        "code":"D3-12400",
                        "display":"Atypical Angina, Variant Angina"
                    },
                    {
                        "code":"D3-83300",
                        "display":"Aortic aneurysm"
                    },
                    {
                        "code":"D3-29042",
                        "display":"Tricuspid regurgitation"
                    },
                    {
                        "code":"D3-13014",
                        "display":"Post-infarction angina"
                    },
                    {
                        "code":"D2-61100",
                        "display":"Pulmonary edema"
                    },
                    {
                        "code":"D3-26000",
                        "display":"Myocarditis"
                    },
                    {
                        "code":"R-00336",
                        "display":"s/p MI positive stress for ischemia"
                    },
                    {
                        "code":"D3-28102",
                        "display":"Subacute bacterial endocarditis"
                    },
                    {
                        "code":"D3-20021",
                        "display":"Congestive cardiomyopathy"
                    },
                    {
                        "code":"D3-13020",
                        "display":"Stable Angina"
                    },
                    {
                        "code":"D3-90100",
                        "display":"Pericardial tamponade"
                    },
                    {
                        "code":"D3-16010",
                        "display":"Congestive heart failure"
                    },
                    {
                        "code":"D3-13021",
                        "display":"Silent ischemia"
                    },
                    {
                        "code":"D3-29096",
                        "display":"Acute mitral regurgitation"
                    },
                    {
                        "code":"D3-29010",
                        "display":"Mitral valve disease"
                    },
                    {
                        "code":"D4-31220",
                        "display":"Atrial septal defect"
                    },
                    {
                        "code":"D3-29050",
                        "display":"Pulmonic valve disease"
                    },
                    {
                        "code":"D3-31720",
                        "display":"Ventricular fibrillation"
                    },
                    {
                        "code":"R-FAE6C",
                        "display":"Arrhythmia"
                    },
                    {
                        "code":"D3-31520",
                        "display":"Atrial fibrillation"
                    },
                    {
                        "code":"F-37012",
                        "display":"Atypical chest pain"
                    },
                    {
                        "code":"D3-91030",
                        "display":"Constrictive pericarditis"
                    },
                    {
                        "code":"D4-31150",
                        "display":"Ventricular septal defect"
                    },
                    {
                        "code":"D3-29020",
                        "display":"Aortic valve disease"
                    },
                    {
                        "code":"D3-29021",
                        "display":"Aortic stenosis"
                    },
                    {
                        "code":"D3-12700",
                        "display":"Unstable Angina, Progressive Angina"
                    },
                    {
                        "code":"R-002CB",
                        "display":"Acute ventricular septal rupture"
                    },
                    {
                        "code":"D3-80016",
                        "display":"Aortic dissection"
                    },
                    {
                        "code":"D3-29011",
                        "display":"Mitral stenosis"
                    },
                    {
                        "code":"D3-29012",
                        "display":"Mitral regurgitation"
                    },
                    {
                        "code":"D3-22100",
                        "display":"Restrictive cardiomyopathy"
                    }
                ]
            }
        ]
    }
}