<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" label="PS3.16" version="5.0" xml:id="PS3.16">
    <title>PS3.16</title>
    <subtitle>DICOM PS3.16 2026b - Content Mapping Resource</subtitle>
    <info>
        <author>
            <orgname>DICOM Standards Committee</orgname>
        </author>
        <copyright>
            <year>2026</year>
            <holder>NEMA</holder>
        </copyright>
        <legalnotice>
            <para xml:id="para_d53aa69c-4da2-482e-82d6-5e501a9ca1a3">A DICOM® publication</para>
        </legalnotice>
    </info>
    <chapter label="" status="1" xml:id="chapter_Notice">
        <title>Notice and Disclaimer</title>
        <para xml:id="para_0030e194-a225-416e-b1d0-1dc26ad01985">The information in this publication was considered technically sound by the consensus of persons engaged in the development and approval of the document at the time it was developed. Consensus does not necessarily mean that there is unanimous agreement among every person participating in the development of this document.</para>
        <para xml:id="para_7df7e416-e5c6-4df3-98a6-621694303daf">NEMA standards and guideline publications, of which the document contained herein is one, are developed through a voluntary consensus standards development process. This process brings together volunteers and/or seeks out the views of persons who have an interest in the topic covered by this publication. While NEMA administers the process and establishes rules to promote fairness in the development of consensus, it does not write the document and it does not independently test, evaluate, or verify the accuracy or completeness of any information or the soundness of any judgments contained in its standards and guideline publications.</para>
        <para xml:id="para_a1b37211-45e1-4116-b69f-e30658cb9b5b">NEMA disclaims liability for any personal injury, property, or other damages of any nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly resulting from the publication, use of, application, or reliance on this document. NEMA disclaims and makes no guaranty or warranty, expressed or implied, as to the accuracy or completeness of any information published herein, and disclaims and makes no warranty that the information in this document will fulfill any of your particular purposes or needs. NEMA does not undertake to guarantee the performance of any individual manufacturer or seller's products or services by virtue of this standard or guide.</para>
        <para xml:id="para_de7f582f-7379-4724-ab9f-98041993a398">In publishing and making this document available, NEMA is not undertaking to render professional or other services for or on behalf of any person or entity, nor is NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstances. Information and other standards on the topic covered by this publication may be available from other sources, which the user may wish to consult for additional views or information not covered by this publication.</para>
        <para xml:id="para_7cb60bdf-0dc1-4f47-a333-1c3f7bfbeb7a">NEMA has no power, nor does it undertake to police or enforce compliance with the contents of this document. NEMA does not certify, test, or inspect products, designs, or installations for safety or health purposes. Any certification or other statement of compliance with any health or safety-related information in this document shall not be attributable to NEMA and is solely the responsibility of the certifier or maker of the statement.</para>
    </chapter>
    <chapter label="" status="1" xml:id="chapter_Foreword">
        <title>Foreword</title>
        <para xml:id="para_6adb128e-4c4b-4f27-b306-1246753d92f1">This DICOM Standard was developed according to the procedures of the DICOM Standards Committee.</para>
        <para xml:id="para_576d1aa2-fb64-4380-86d5-ab54051fa785">The DICOM Standard is structured as a multi-part document using the guidelines established in <xref linkend="biblio_ISODirectives2"/>.</para>
        <para xml:id="para_2d703230-a1ee-4407-926b-7fbaca4c89e9">
            <olink targetdoc="PS3.1" targetptr="PS3.1" xrefstyle="select: labelnumber"/> should be used as the base reference for the current parts of this Standard.</para>
        <para xml:id="para_7a2b31a6-31a8-47ef-92b0-7152b8fb7730">DICOM® is the registered trademark of the National Electrical Manufacturers Association for its standards publications relating to digital communications of medical information, all rights reserved.</para>
        <para xml:id="para_4483f1c0-f257-4ff4-a060-52df924f5c95">HL7® and CDA® are the registered trademarks of Health Level Seven International, all rights reserved.</para>
        <para xml:id="para_ca4a936e-b9cb-46f7-a0af-19ea289a3282">SNOMED®, SNOMED Clinical Terms®, SNOMED CT® are the registered trademarks of SNOMED International, all rights reserved.</para>
        <para xml:id="para_afb5f9f0-06f9-4d52-b7ab-dbdef10c5ad5">LOINC® is the registered trademark of Regenstrief Institute, Inc, all rights reserved.</para>
    </chapter>
    <chapter label="1" status="1" xml:id="chapter_1">
        <title>Scope and Field of Application</title>
        <para xml:id="para_b324662c-c231-4c64-85b9-6bf39bbe7fa7">This Part of the DICOM Standard specifies the DICOM Content Mapping Resource (DCMR), which defines the Templates and Context Groups used elsewhere in the Standard.</para>
    </chapter>
    <chapter label="2" status="1" xml:id="chapter_2">
        <title>Normative References</title>
        <para xml:id="para_1589f5e4-c13c-4b23-aa20-8280f62270a0">The following standards contain provisions that, through reference in this text, constitute provisions of this Standard. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this Standard are encouraged to investigate the possibilities of applying the most recent editions of the standards indicated below.</para>
        <bibliography>
            <title/>
            <bibliodiv label="2.1" status="2" xml:id="sect_2.1">
                <title>General</title>
                <biblioentry xml:id="biblio_Alderman_1992">
                    <abbrev>Alderman 1992</abbrev>
                    <biblioset relation="journal">
                        <title>Coronary Artery Disease</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Alderman EL</personname>
                            </author>
                            <author>
                                <personname>Stadius M</personname>
                            </author>
                        </authorgroup>
                        <date>1992</date>
                        <volumenum>3</volumenum>
                        <issuenum>12</issuenum>
                        <pagenums>1189-208</pagenums>
                        <title>The angiographic definitions of the bypass angioplasty revascularization investigation</title>
                    </biblioset>
                    <bibliosource>
                        <link xl:href="http://journals.lww.com/coronary-artery/Abstract/1992/12000/The_angiographie_definitions_of_the_Bypass.12.aspx"/>
                    </bibliosource>
                </biblioentry>
                <biblioentry xml:id="biblio_Berry_2012">
                    <abbrev>Berry 2012</abbrev>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Berry RB</personname>
                            </author>
                            <author>
                                <personname>Brooks R</personname>
                            </author>
                            <author>
                                <personname>Gamaldo CE</personname>
                            </author>
                        </authorgroup>
                        <date>2012</date>
                        <title>The AASM Manual for the scoring of sleep and associated events: rules, terminology and technical specifications. Version 2.0.</title>
                    </biblioset>
                    <bibliosource>
                        <link xl:href="http://www.aasmnet.org"/>
                    </bibliosource>
                </biblioentry>
                <biblioentry xml:id="biblio_ASTM_E1762_04">
                    <abbrev>ASTM E 1762-04</abbrev>
                    <author>
                        <orgname>ASTM</orgname>
                    </author>
                    <date/>
                    <title>Standard Guide for Electronic Authentication of Health Care Information, ASTM International</title>
                </biblioentry>
                <biblioentry xml:id="biblio_ASTM_E2084_00">
                    <abbrev>ASTM E 2084-00</abbrev>
                    <author>
                        <orgname>ASTM</orgname>
                    </author>
                    <date/>
                    <title>Standard Specification for Authentication of Healthcare Information Using Digital Signatures, ASTM International</title>
                </biblioentry>

                <biblioentry xml:id="biblio_ASTM_F67">
                    <abbrev>ASTM F 67</abbrev>
                    <author>
                        <orgname>ASTM</orgname>
                    </author>
                    <date/>
                    <title>Standard Specification for Unalloyed Titanium, for Surgical Implant Applications</title>
                </biblioentry>
                <biblioentry xml:id="biblio_ASTM_F75">
                    <abbrev>ASTM F 75</abbrev>
                    <author>
                        <orgname>ASTM</orgname>
                    </author>
                    <date/>
                    <title>Standard Specification for Cobalt-28 Chromium-6 Molybdenum Alloy Castings and Casting Alloy for Surgical Implants</title>
                </biblioentry>
                <biblioentry xml:id="biblio_ASTM_F90">
                    <abbrev>ASTM F 90</abbrev>
                    <author>
                        <orgname>ASTM</orgname>
                    </author>
                    <date/>
                    <title>Standard Specification for Wrought Cobalt-20Chromium-15Tungsten-10Nickel Alloy for Surgical Implant Applications</title>
                </biblioentry>
                <biblioentry xml:id="biblio_ASTM_F136">
                    <abbrev>ASTM F 136</abbrev>
                    <author>
                        <orgname>ASTM</orgname>
                    </author>
                    <date/>
                    <title>Standard Specification for Wrought Titanium-6Aluminum-4Vanadium ELI (Extra Low Interstitial) Alloy for Surgical Implant Applications</title>
                </biblioentry>
                <biblioentry xml:id="biblio_ASTM_F138">
                    <abbrev>ASTM F 138</abbrev>
                    <author>
                        <orgname>ASTM</orgname>
                    </author>
                    <date/>
                    <title>Standard Specification for Wrought 18Chromium-14Nickel-2.5Molybdenum Stainless Steel Bar and Wire for Surgical Implants</title>
                </biblioentry>
                <biblioentry xml:id="biblio_ASTM_F688">
                    <abbrev>ASTM F 688</abbrev>
                    <author>
                        <orgname>ASTM</orgname>
                    </author>
                    <date/>
                    <title>Standard Specification for Wrought Cobalt-35Nickel-20Chromium-10Molybdenum Alloy Plate, Sheet, and Foil for Surgical Implants</title>
                </biblioentry>
                <biblioentry xml:id="biblio_ASTM_F1058">
                    <abbrev>ASTM F 1058</abbrev>
                    <author>
                        <orgname>ASTM</orgname>
                    </author>
                    <date/>
                    <title>Standard Specification for Wrought 40Cobalt-20Chromium-16Iron-15Nickel-7Molybdenum Alloy Wire, Strip, and Strip Bar for Surgical Implant Applications</title>
                </biblioentry>
                <biblioentry xml:id="biblio_ASTM_F1295">
                    <abbrev>ASTM F 1295</abbrev>
                    <author>
                        <orgname>ASTM</orgname>
                    </author>
                    <date/>
                    <title>Standard Specification for Wrought Titanium-6Aluminum-7Niobium Alloy for Surgical Implant Applications</title>
                </biblioentry>

                <biblioentry xml:id="biblio_AAPM_TG204">
                    <abbrev>AAPM Report 204</abbrev>
                    <author>
                        <orgname>American Association of Physicists in Medicine, College Park, Maryland</orgname>
                    </author>
                    <date>2011</date>
                    <title>Size-Specific Dose Estimates (SSDE) in Pediatric and Adult Body CT Examinations</title>
                    <bibliosource>
                        <link xl:href="http://www.aapm.org/pubs/reports/RPT_204.pdf"/>
                    </bibliosource>
                </biblioentry>
                <biblioentry xml:id="biblio_AAPM_TG220">
                    <abbrev>AAPM Report 220</abbrev>
                    <author>
                        <orgname>American Association of Physicists in Medicine</orgname>
                    </author>
                    <date>September 2014</date>
                    <title>Report of AAPM Task Group 220 - Use of Water Equivalent Diameter for Calculating Patient Size and Size-Specific Dose Estimates (SSDE) in CT</title>
                    <bibliosource>
                        <link xl:href="http://www.aapm.org/pubs/reports/rpt_220.pdf"/>
                    </bibliosource>
                </biblioentry>
                <biblioentry xml:id="biblio_AAPM_OR03">
                    <abbrev>AAPM OR 03</abbrev>
                    <author>
                        <orgname>American Association of Physicists in Medicine</orgname>
                    </author>
                    <date>2005</date>
                    <title>Assessment of Display Performance for Medical Imaging Systems</title>
                    <bibliosource>
                        <link xl:href="http://www.aapm.org/pubs/reports/OR_03.pdf"/>
                    </bibliosource>
                </biblioentry>
                <biblioentry xml:id="biblio_ETDRS_10">
                    <abbrev>ETDRS Report Number 10</abbrev>
                    <author>
                        <orgname>ETDRS</orgname>
                    </author>
                    <date/>
                    <title>Report Number 10, Grading Diabetic Retinopathy from Stereoscopic Color Fundus Photographs- An Extension of the Modified Airlie House Classification. Ophthalmology, May 1991, vol98 (p786-805), Supplement</title>
                </biblioentry>
                <biblioentry xml:id="biblio_Feuvret">
                    <abbrev>Feuvret</abbrev>
                    <biblioset relation="journal">
                        <title>International Journal of Radiation Oncology, Biology, Physics</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Feuvret L</personname>
                            </author>
                            <author>
                                <personname>Noël G</personname>
                            </author>
                            <author>
                                <personname>Mazeron JJ</personname>
                            </author>
                            <author>
                                <personname>Bey P</personname>
                            </author>
                        </authorgroup>
                        <date>2006</date>
                        <volumenum>64</volumenum>
                        <issuenum>2</issuenum>
                        <pagenums>333-342</pagenums>
                        <title>Conformity index: a review</title>
                    </biblioset>
                    <bibliosource>
                        <link xl:href="http://dx.doi.org/10.1016/j.ijrobp.2005.09.028"/>
                    </bibliosource>
                </biblioentry>
                <biblioentry xml:id="biblio_HL7v3_CMET">
                    <abbrev>HL7 v3 CMET</abbrev>
                    <author>
                        <orgname>HL7</orgname>
                    </author>
                    <date/>
                    <title>Version 3 Standard: Common Message Element Types</title>
                </biblioentry>
                <biblioentry xml:id="biblio_IBSI_Features">
                    <abbrev>IBSI Features</abbrev>
                    <biblioset relation="journal">
                        <title>&gt;arXiv</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Zwanenburg A</personname>
                            </author>
                            <author>
                                <personname>Leger S</personname>
                            </author>
                            <author>
                                <personname>Vallières M</personname>
                            </author>
                            <author>
                                <personname>Löck S</personname>
                            </author>
                        </authorgroup>
                        <date>17 Sep 2018</date>
                        <volumenum>arXiv:1612.07003v7</volumenum>
                        <title>Image biomarker standardisation initiative - Reference manual</title>
                    </biblioset>
                    <bibliosource>
                        <link xl:href="http://arxiv.org/abs/1612.07003"/>
                    </bibliosource>
                </biblioentry>
                <biblioentry xml:id="biblio_ICRU50">
                    <abbrev>ICRU Report 50</abbrev>
                    <author>
                        <orgname>International Commission on Radiation Units and Measurements</orgname>
                    </author>
                    <date>1993</date>
                    <title>Prescribing, Recording, and Reporting Photon Beam Therapy</title>
                </biblioentry>
                <biblioentry xml:id="biblio_ICRU62">
                    <abbrev>ICRU Report 62</abbrev>
                    <author>
                        <orgname>International Commission on Radiation Units and Measurements</orgname>
                    </author>
                    <date>1999</date>
                    <title>Prescribing, recording, and reporting photon beam therapy (supplement to ICRU Report 50)</title>
                </biblioentry>
                <biblioentry xml:id="biblio_IEC60601_2_1">
                    <abbrev>IEC 60601-2-1</abbrev>
                    <author>
                        <orgname>IEC</orgname>
                    </author>
                    <date/>
                    <title>Medical Electrical Equipment - Part 2-1: Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV</title>
                </biblioentry>
                <biblioentry xml:id="biblio_IEC60601_2_44">
                    <abbrev>IEC 60601-2-44</abbrev>
                    <author>
                        <orgname>IEC</orgname>
                    </author>
                    <date/>
                    <title>Medical Electrical Equipment - Part 2-44: Particular Requirements for the Safety of X-Ray Equipment for Computed Tomography</title>
                </biblioentry>
                <biblioentry xml:id="biblio_IEC60601-2-64">
                    <abbrev>IEC 60601-2-64</abbrev>
                    <author>
                        <orgname>IEC</orgname>
                    </author>
                    <date/>
                    <title>Medical Electrical Equipment - Part 2-64: Particular requirements for the basic safety and essential performance of light ion beam medical electrical equipment</title>
                </biblioentry>
                <biblioentry xml:id="biblio_IEC61217-2">
                    <abbrev>IEC 61217</abbrev>
                    <author>
                        <orgname>IEC</orgname>
                    </author>
                    <date>2011</date>
                    <edition>Ed 2.0</edition>
                    <title>Radiotherapy Equipment - Coordinates, Movements and Scales</title>
                </biblioentry>
                <biblioentry xml:id="biblio_IEC62563-1">
                    <abbrev>IEC 62563-1</abbrev>
                    <author>
                        <orgname>IEC</orgname>
                    </author>
                    <date>2009</date>
                    <edition>Ed 1.0</edition>
                    <title>Medical Electrical Equipment - Medical image display systems - Part 1: Evaluation methods</title>
                </biblioentry>
                <biblioentry xml:id="biblio_IEC62985">
                    <abbrev>IEC 62985</abbrev>
                    <author>
                        <orgname>IEC</orgname>
                    </author>
                    <date>2019</date>
                    <title>Methods For Calculating Size Specific Dose Estimates (SSDE) For Computed Tomography</title>
                </biblioentry>
                <biblioentry xml:id="biblio_IHE_RAD_TF_1">
                    <abbrev>IHE RAD TF-1</abbrev>
                    <author>
                        <orgname>IHE International</orgname>
                    </author>
                    <title>IHE Radiology (RAD) Technical Framework, Volume 1 - Integration Profiles</title>
                    <bibliosource>
                        <link xl:href="http://www.ihe.net/uploadedFiles/Documents/Radiology/IHE_RAD_TF_Vol1.pdf"/>
                    </bibliosource>
                </biblioentry>
                <biblioentry xml:id="biblio_ISODirectives2">
                    <abbrev>ISO/IEC Directives, Part 2</abbrev>
                    <author>
                        <orgname>ISO/IEC</orgname>
                    </author>
                    <date>2021</date>
                    <edition>9.0</edition>
                    <title>Rules for the structure and drafting of International Standards</title>
                    <bibliosource>
                        <link xl:href="http://www.iso.org/sites/directives/current/part2/index.xhtml"/>
                    </bibliosource>
                </biblioentry>
                <biblioentry xml:id="biblio_ISO639">
                    <abbrev>ISO 639</abbrev>
                    <author>
                        <orgname>ISO</orgname>
                    </author>
                    <date/>
                    <title>Codes for the representation of names of languages</title>
                </biblioentry>
                <biblioentry xml:id="biblio_ISO639-1">
                    <abbrev>ISO 639-1</abbrev>
                    <author>
                        <orgname>ISO</orgname>
                    </author>
                    <date>2002</date>
                    <title>Codes for the representation of names of languages — Part 1: Alpha-2 code</title>
                </biblioentry>
                <biblioentry xml:id="biblio_ISO639-2">
                    <abbrev>ISO 639-2</abbrev>
                    <author>
                        <orgname>ISO</orgname>
                    </author>
                    <date>1998</date>
                    <title>Codes for the representation of names of languages — Part 2: Alpha-3 code</title>
                </biblioentry>
                <biblioentry xml:id="biblio_ISO639-3">
                    <abbrev>ISO 639-3</abbrev>
                    <author>
                        <orgname>ISO</orgname>
                    </author>
                    <date>2007</date>
                    <title>Codes for the representation of names of languages — Part 3: Alpha-3 code for comprehensive coverage of languages</title>
                </biblioentry>
                <biblioentry xml:id="biblio_ISO3166">
                    <abbrev>ISO 3166</abbrev>
                    <author>
                        <orgname>ISO</orgname>
                    </author>
                    <date/>
                    <title>Codes for the representation of names of countries</title>
                </biblioentry>
                <biblioentry xml:id="biblio_ISO3166-1">
                    <abbrev>ISO 3166-1</abbrev>
                    <author>
                        <orgname>ISO</orgname>
                    </author>
                    <date/>
                    <title>Codes for the representation of names of countries — Part 1: Country codes</title>
                </biblioentry>
                <biblioentry xml:id="biblio_ISO5832-1">
                    <abbrev>ISO 5832-1</abbrev>
                    <author>
                        <orgname>ISO</orgname>
                    </author>
                    <date/>
                    <title>Implants for surgery – Metallic materials — Part 1: Wrought stainless steel</title>
                </biblioentry>
                <biblioentry xml:id="biblio_ISO5832-2">
                    <abbrev>ISO 5832-2</abbrev>
                    <author>
                        <orgname>ISO</orgname>
                    </author>
                    <date/>
                    <title>Implants for surgery – Metallic materials — Part 2: Unalloyed titanium</title>
                </biblioentry>
                <biblioentry xml:id="biblio_ISO5832-3">
                    <abbrev>ISO 5832-3</abbrev>
                    <author>
                        <orgname>ISO</orgname>
                    </author>
                    <date/>
                    <title>Implants for surgery – Metallic materials — Part 3: Wrought titanium 6-aluminium 4-vanadium alloy</title>
                </biblioentry>
                <biblioentry xml:id="biblio_ISO5832-4">
                    <abbrev>ISO 5832-4</abbrev>
                    <author>
                        <orgname>ISO</orgname>
                    </author>
                    <date/>
                    <title>Implants for surgery – Metallic materials — Part 4: Cobalt-chromium-molybdenum casting alloy</title>
                </biblioentry>
                <biblioentry xml:id="biblio_ISO5832-5">
                    <abbrev>ISO 5832-5</abbrev>
                    <author>
                        <orgname>ISO</orgname>
                    </author>
                    <date/>
                    <title>Implants for surgery – Metallic materials — Part 5: Wrought cobalt-chromium-tungsten-nickel alloy</title>
                </biblioentry>
                <biblioentry xml:id="biblio_ISO5832-6">
                    <abbrev>ISO 5832-6</abbrev>
                    <author>
                        <orgname>ISO</orgname>
                    </author>
                    <date/>
                    <title>Implants for surgery – Metallic materials — Part 6: Wrought cobalt-nickel-chromium-molybdenum alloy</title>
                </biblioentry>
                <biblioentry xml:id="biblio_ISO5832-7">
                    <abbrev>ISO 5832-7</abbrev>
                    <author>
                        <orgname>ISO</orgname>
                    </author>
                    <date/>
                    <title>Implants for surgery – Metallic materials — Part 7: Forgeable and cold-formed cobalt-chromium-nickel-molybdenum-iron alloy</title>
                </biblioentry>
                <biblioentry xml:id="biblio_ISO5832-11">
                    <abbrev>ISO 5832-11</abbrev>
                    <author>
                        <orgname>ISO</orgname>
                    </author>
                    <date/>
                    <title>Implants for surgery – Metallic materials — Part 11: Wrought titanium 6-aluminium 7-niobium alloy</title>
                </biblioentry>
                <biblioentry xml:id="biblio_ISO5832-14">
                    <abbrev>ISO 5832-14</abbrev>
                    <author>
                        <orgname>ISO</orgname>
                    </author>
                    <date/>
                    <title>Implants for surgery – Metallic materials — Part 14: Wrought titanium 15-molybdenum 5-zirconium 3-aluminium alloy</title>
                </biblioentry>

                <biblioentry xml:id="biblio_ISO8824-1">
                    <abbrev>ISO 8824-1</abbrev>
                    <author>
                        <orgname>ISO</orgname>
                    </author>
                    <date>2015</date>
                    <title>Information Technology - Abstract Syntax 1 (ASN.1): Specification of Basic Notation</title>
                </biblioentry>
                <biblioentry xml:id="biblio_ISO9834-1">
                    <abbrev>ISO 9834-1</abbrev>
                    <author>
                        <orgname>ISO</orgname>
                    </author>
                    <date>2012</date>
                    <title>Information technology - Open Systems Interconnection - Procedures for the operation of OSI Registration Authorities: General procedures and top arcs of the ASN.1 Object Identifier tree</title>
                </biblioentry>
                <biblioentry xml:id="biblio_ISO15924">
                    <abbrev>ISO 15924</abbrev>
                    <author>
                        <orgname>ISO</orgname>
                    </author>
                    <date>2004</date>
                    <title>Codes for the representation of names of scripts</title>
                </biblioentry>
                <biblioentry xml:id="biblio_JJ1017">
                    <abbrev>JJ1017</abbrev>
                    <author>
                        <orgname>Japan Medical Imaging and Radiological Systems Industries Association (JIRA) and Japanese Association of Healthcare Information Systems Industry (JAHIS)</orgname>
                    </author>
                    <date>October 5, 2005</date>
                    <edition>3.0</edition>
                    <title>Guidelines for HIS, RIS, PACS - Modality Data Communication on Scheduling, Billing, and Examination Records</title>
                    <bibliosource>
                        <link xl:href="http://www.jira-net.or.jp/commission/system/04_information/files/JJ1017VER3_20051005.doc"/>
                    </bibliosource>
                </biblioentry>
                <biblioentry xml:id="biblio_Kenneweg_2019">
                    <abbrev>Kenneweg 2019</abbrev>
                    <biblioset relation="journal">
                        <title>J Am Acad Dermatol</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Kenneweg KA</personname>
                            </author>
                            <author>
                                <personname>et al</personname>
                            </author>
                        </authorgroup>
                        <date>2019</date>
                        <volumenum>80</volumenum>
                        <issuenum>6</issuenum>
                        <pagenums>1564–84</pagenums>
                        <title>Developing an international standard for the classification of surface anatomic location for use in clinical practice and epidemiologic research</title>
                        <biblioid class="doi">10.1016/j.jaad.2018.08.035</biblioid>
                    </biblioset>
                    <bibliosource>
                        <link xl:href="http://www.jaad.org/article/S0190-9622(18)32489-7/"/>
                    </bibliosource>
                </biblioentry>
                <biblioentry xml:id="biblio_NEMA_XR_25">
                    <abbrev>NEMA XR 25-2019</abbrev>
                    <author>
                        <orgname>National Electrical Manufacturers Association, Rosslyn, Virginia</orgname>
                    </author>
                    <date>2019</date>
                    <title>Computed Tomography Dose Check Standard</title>
                    <bibliosource>
                        <link xl:href="http://www.nema.org/Standards/view/Computed-Tomography-Dose-Check"/>
                    </bibliosource>
                </biblioentry>
                <biblioentry xml:id="biblio_RadLex">
                    <abbrev>RadLex</abbrev>
                    <author>
                        <orgname>RSNA, Chicago</orgname>
                    </author>
                    <date>2006</date>
                    <title>A Lexicon for Uniform Indexing and Retrieval of Radiology Information Resources</title>
                    <bibliosource>
                        <link xl:href="http://www.radlex.org/"/>
                    </bibliosource>
                </biblioentry>
                <biblioentry xml:id="biblio_RadElement">
                    <abbrev>RadElement</abbrev>
                    <author>
                        <orgname>RSNA, Chicago</orgname>
                    </author>
                    <title>Common Data Elements (CDEs) for Radiology</title>
                    <bibliosource>
                        <link xl:href="http://radelement.org/"/>
                    </bibliosource>
                </biblioentry>
                <biblioentry xml:id="biblio_RFC_1766">
                    <abbrev>RFC 1766</abbrev>
                    <author>
                        <orgname>IETF</orgname>
                    </author>
                    <date>March 1995</date>
                    <title>Tags for the Identification of Languages</title>
                </biblioentry>
                <biblioentry xml:id="biblio_RFC_3066">
                    <abbrev>RFC 3066</abbrev>
                    <author>
                        <orgname>IETF</orgname>
                    </author>
                    <date>January 2001</date>
                    <title>Tags for the Identification of Languages</title>
                </biblioentry>
                <biblioentry xml:id="biblio_RFC_3881">
                    <abbrev>RFC 3881</abbrev>
                    <author>
                        <orgname>IETF</orgname>
                    </author>
                    <date>September 2004</date>
                    <title>Security Audit and Access Accountability Message - XML Data Definitions for Healthcare Applications</title>
                </biblioentry>
                <biblioentry xml:id="biblio_RFC_3986">
                    <abbrev>RFC 3986</abbrev>
                    <author>
                        <orgname>IETF</orgname>
                    </author>
                    <date>January 2005</date>
                    <title>Uniform Resource Identifier (URI): Generic Syntax</title>
                    <bibliosource>
                        <link xl:href="http://www.rfc-editor.org/info/rfc3986"/>
                    </bibliosource>
                </biblioentry>
                <biblioentry xml:id="biblio_RFC_4646">
                    <abbrev>RFC 4646</abbrev>
                    <author>
                        <orgname>IETF</orgname>
                    </author>
                    <date>September 2006</date>
                    <title>Tags for Identifying Languages</title>
                </biblioentry>
                <biblioentry xml:id="biblio_RFC_4647">
                    <abbrev>RFC 4647</abbrev>
                    <author>
                        <orgname>IETF</orgname>
                    </author>
                    <date>September 2006</date>
                    <title>Matching of Language Tags</title>
                </biblioentry>
                <biblioentry xml:id="biblio_RFC_5646">
                    <abbrev>RFC 5646</abbrev>
                    <author>
                        <orgname>IETF</orgname>
                    </author>
                    <date>September 2009</date>
                    <title>Tags for Identifying Languages</title>
                </biblioentry>
                <biblioentry xml:id="biblio_SAE-J1086_201210">
                    <abbrev>J1086_201210</abbrev>
                    <author>
                        <orgname>SAE</orgname>
                    </author>
                    <date>Oct 2012</date>
                    <title>Numbering Metals and Alloys</title>
                    <bibliosource>
                        <link xl:href="http://www.sae.org/standards/content/j1086_201210/"/>
                    </bibliosource>
                </biblioentry>
                <biblioentry xml:id="biblio_Scanlon_1999">
                    <abbrev>Scanlon 1999</abbrev>
                    <biblioset relation="journal">
                        <title>Journal of the American College of Cardiology</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Scanlon PJ</personname>
                            </author>
                            <author>
                                <personname>et al</personname>
                            </author>
                        </authorgroup>
                        <date>May 1999</date>
                        <volumenum>33</volumenum>
                        <issuenum>6</issuenum>
                        <pagenums>1756-824</pagenums>
                        <title>ACC/AHA guidelines for coronary angiography - A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Coronary Angiography) developed in collaboration with the Society for Cardiac Angiography and Interventions</title>
                        <biblioid class="doi">10.1016/S0735-1097(99)00126-6</biblioid>
                    </biblioset>
                    <bibliosource>
                        <link xl:href="http://www.sciencedirect.com/science/article/pii/S0735109799001266"/>
                    </bibliosource>
                </biblioentry>
                <biblioentry xml:id="biblio_Seeck_2017">
                    <abbrev>Seeck 2017</abbrev>
                    <biblioset relation="journal">
                        <title>Clinical Neurophysiology</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Seeck M</personname>
                            </author>
                            <author>
                                <personname>et al</personname>
                            </author>
                        </authorgroup>
                        <date>2017</date>
                        <volumenum>128</volumenum>
                        <issuenum>10</issuenum>
                        <pagenums>2070-7</pagenums>
                        <title>The standardized EEG electrode array of the IFCN</title>
                        <biblioid class="doi">10.1016/j.clinph.2017.06.254</biblioid>
                    </biblioset>
                    <bibliosource>
                        <link xl:href="http://www.sciencedirect.com/science/article/pii/S1388245717304832"/>
                    </bibliosource>
                </biblioentry>
                <biblioentry xml:id="biblio_SMPTE_RP133">
                    <abbrev>SMPTE RP133</abbrev>
                    <author>
                        <orgname>Society of Motion Picture and Television Engineers (SMPTE)</orgname>
                    </author>
                    <date>1991</date>
                    <title>Specifications for Medical Diagnostic Imaging Test Pattern for Television Monitors and Hard-copy Recording Cameras</title>
                </biblioentry>
                <biblioentry xml:id="biblio_Stout_2013">
                    <abbrev>Stout et al 2013</abbrev>
                    <biblioset relation="journal">
                        <title>Molecular Imaging</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Stout D</personname>
                            </author>
                            <author>
                                <personname>Berr SS</personname>
                            </author>
                            <author>
                                <personname>LeBlanc A</personname>
                            </author>
                            <author>
                                <personname>Kalen JD</personname>
                            </author>
                            <author>
                                <personname>Osborne D</personname>
                            </author>
                            <author>
                                <personname>Price J</personname>
                            </author>
                            <author>
                                <personname>Schiffer W</personname>
                            </author>
                            <author>
                                <personname>Kuntner C</personname>
                            </author>
                            <author>
                                <personname>Wall J</personname>
                            </author>
                        </authorgroup>
                        <date>2013</date>
                        <volumenum>12</volumenum>
                        <issuenum>7</issuenum>
                        <pagenums>1-15</pagenums>
                        <title>Guidance for Methods Descriptions Used in Preclinical Imaging Papers</title>
                    </biblioset>
                    <bibliosource>
                        <link xl:href="http://journals.sagepub.com/doi/pdf/10.2310/7290.2013.00055"/>
                    </bibliosource>
                </biblioentry>
            </bibliodiv>
            <bibliodiv label="2.2" status="2" xml:id="sect_2.2">
                <title>BI-RADS® Terminology and Nomenclature</title>
                <para xml:id="para_d18e1feb-a054-42b8-b36c-708fc098117a">A portion of the terminology used within the Mammography CAD SR SOP Class and the Breast Imaging Report and Relevant Patient Information for Breast Imaging Templates is derived from BI-RADS®, a copyrighted lexicon of breast imaging terminology and nomenclature licensed by DICOM from the American College of Radiology.</para>
                <biblioentry xml:id="biblio_BIRADS">
                    <abbrev>BI-RADS®</abbrev>
                    <author>
                        <orgname>American College of Radiology, Reston, Virginia</orgname>
                    </author>
                    <date>1998</date>
                    <edition>3.0</edition>
                    <title>Breast Imaging Reporting and Data System Atlas</title>
                    <bibliosource>
                        <link xl:href="http://www.acr.org/Quality-Safety/Resources/BIRADS"/>
                    </bibliosource>
                </biblioentry>
            </bibliodiv>
            <bibliodiv label="2.3" status="2" xml:id="sect_2.3">
                <title>MQCM 1999 Terminology and Nomenclature</title>
                <para xml:id="para_e17a7760-e03f-432d-98f5-362c88c93e0f">References to MQCM 1999 are made in the description of the Mammography CAD SR SOP Class. In this MQCM 1999 refers to the Mammography Quality Control Manual 1999, available from the American College of Radiology. This document describes a standardized approach to mammographic acquisition standards, patient positioning, and so on. The DICOM Standard does not require Mammography CAD SR SOP Class implementations to adhere to MQCM 1999.</para>
                <biblioentry xml:id="biblio_MQCM">
                    <abbrev>MQCM</abbrev>
                    <author>
                        <orgname>American College of Radiology, Reston, Virginia</orgname>
                    </author>
                    <date>1999</date>
                    <title>Mammography Quality Control Manual</title>
                    <bibliosource>
                        <link xl:href="http://www.acr.org/Education/Education-Catalog/Products/639"/>
                    </bibliosource>
                </biblioentry>
            </bibliodiv>
            <bibliodiv label="2.4" status="2" xml:id="sect_2.4">
                <title>MQSA Terminology and Nomenclature</title>
                <para xml:id="para_6ddb8794-1b03-489f-bdad-b577794070da">References to MQSA are made in the description of the Mammography CAD SR SOP Class. In this MQSA refers to the Mammography Quality Standards Act final rules. While MQSA is a federal regulation of the United States government, it provides the only widely published standards for mammographic quality and is incorporated in this document for that reason. The DICOM Standard does not require Mammography CAD SR SOP Class implementations to adhere to MQSA.</para>
                <biblioentry xml:id="biblio_MQSA">
                    <abbrev>MQSA</abbrev>
                    <author>
                        <orgname>U.S. Food and Drug Administration, Silver Spring, Maryland</orgname>
                    </author>
                    <date>2002</date>
                    <title>Mammography Quality Standards Act Regulations</title>
                    <bibliosource>
                        <link xl:href="http://www.fda.gov/Radiation-EmittingProducts/MammographyQualityStandardsActandProgram/Regulations/ucm110906.htm"/>
                    </bibliosource>
                </biblioentry>
            </bibliodiv>
            <bibliodiv label="2.5" status="2" xml:id="sect_2.5">
                <title>ACR Position Statement</title>
                <biblioentry xml:id="biblio_ACRPosState">
                    <abbrev>ACR Position Statement</abbrev>
                    <author>
                        <orgname>American College of Radiology, Reston, Virginia</orgname>
                    </author>
                    <date>2001</date>
                    <title>Quality Control and Improvement, Safety, Infection Control, and Patient Education</title>
                    <bibliosource>
                        <link xl:href="http://www.acr.org/Quality-Safety/Radiology-Safety"/>
                    </bibliosource>
                </biblioentry>
            </bibliodiv>
            <bibliodiv label="2.6" status="2" xml:id="sect_2.6">
                <title>Chest Radiology and CT</title>
                <para xml:id="para_e82b9634-5628-4cdc-8ba7-f17cebad6054">References are made in the description of the Chest CAD SR Templates and Context Groups.</para>
                <biblioentry xml:id="biblio_FraserPareRadiology">
                    <abbrev>Fraser and Pare</abbrev>
                    <authorgroup>
                        <author>
                            <personname>Fraser</personname>
                        </author>
                        <author>
                            <personname>Muller</personname>
                        </author>
                        <author>
                            <personname>Colman</personname>
                        </author>
                        <author>
                            <personname>Pare</personname>
                        </author>
                    </authorgroup>
                    <date>1999</date>
                    <edition>4th</edition>
                    <volumenum>I</volumenum>
                    <pagenums>xvii-xxxi</pagenums>
                    <title>Diagnosis of Diseases of the Chest</title>
                    <subtitle>Terms Used in Chest Radiology</subtitle>
                </biblioentry>
                <biblioentry xml:id="biblio_FraserPareCT">
                    <abbrev>Fraser and Pare</abbrev>
                    <authorgroup>
                        <author>
                            <personname>Fraser</personname>
                        </author>
                        <author>
                            <personname>Muller</personname>
                        </author>
                        <author>
                            <personname>Colman</personname>
                        </author>
                        <author>
                            <personname>Pare</personname>
                        </author>
                    </authorgroup>
                    <date>1999</date>
                    <edition>4th</edition>
                    <volumenum>I</volumenum>
                    <pagenums>xxxiii-xxxvi</pagenums>
                    <title>Diagnosis of Diseases of the Chest</title>
                    <subtitle>Terms for CT of the Lungs</subtitle>
                </biblioentry>
                <biblioentry xml:id="biblio_ACRCTPE">
                    <abbrev>ACR CT PE</abbrev>
                    <author>
                        <orgname>American College of Radiology, Reston, Virginia</orgname>
                    </author>
                    <date>2001</date>
                    <pagenums>109-113</pagenums>
                    <title>ACR Standards</title>
                    <subtitle>ACR Standard for the Performance of Computed Tomography for the Detection of Pulmonary Embolism in Adults</subtitle>
                </biblioentry>
                <biblioentry xml:id="biblio_ACRHRCT">
                    <abbrev>ACR HR CT</abbrev>
                    <author>
                        <orgname>American College of Radiology, Reston, Virginia</orgname>
                    </author>
                    <date>2001</date>
                    <pagenums>115-118</pagenums>
                    <title>ACR Standards</title>
                    <subtitle>ACR Standard for the Performance of High-Resolution Computed Tomography (HRCT) of the Lungs in Adults</subtitle>
                </biblioentry>
                <biblioentry xml:id="biblio_ACRCR">
                    <abbrev>ACR Radiography</abbrev>
                    <author>
                        <orgname>American College of Radiology, Reston, Virginia</orgname>
                    </author>
                    <date>2001</date>
                    <pagenums>95-98</pagenums>
                    <title>ACR Standards</title>
                    <subtitle>ACR Standard for the Performance of Pediatric and Adult Chest Radiography</subtitle>
                </biblioentry>
                <biblioentry xml:id="biblio_ACRCT">
                    <abbrev>ACR Thoracic CT</abbrev>
                    <author>
                        <orgname>American College of Radiology, Reston, Virginia</orgname>
                    </author>
                    <date>2001</date>
                    <pagenums>103-107</pagenums>
                    <title>ACR Standards</title>
                    <subtitle>ACR Standard for the Performance of Pediatric and Adult Thoracic Computed Tomography (CT)</subtitle>
                </biblioentry>
            </bibliodiv>
            <bibliodiv label="2.7" status="2" xml:id="sect_2.7">
                <title>Response Evaluation Criteria</title>
                <para xml:id="para_c2edc6a1-3a61-43f8-a766-63ab5f3ce614">References to Response Evaluation Criteria are made from the Chest CAD SR Templates and Context Groups</para>
                <biblioentry xml:id="biblio_RECIST">
                    <abbrev>RECIST</abbrev>
                    <biblioset relation="journal">
                        <title>Journal of the National Cancer Institute</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Therasse</personname>
                            </author>
                        </authorgroup>
                        <date>February 2, 2000</date>
                        <volumenum>92</volumenum>
                        <issuenum>3</issuenum>
                        <pagenums>205-216</pagenums>
                        <title>New Guidelines to Evaluate the Response to Treatment in Solid Tumors</title>
                    </biblioset>
                    <bibliosource>
                        <link xl:href="http://www.eortc.be/recist/"/>
                    </bibliosource>
                </biblioentry>
                <biblioentry xml:id="biblio_WHO">
                    <abbrev>WHO</abbrev>
                    <author>
                        <orgname>World Health Organization, Geneva</orgname>
                    </author>
                    <date>1979</date>
                    <title>WHO Handbook for Reporting Results for Cancer Treatment</title>
                    <subtitle>WHO Offset Publication No. 48</subtitle>
                    <bibliosource>
                        <link xl:href="http://whqlibdoc.who.int/publications/9241700483.pdf"/>
                    </bibliosource>
                </biblioentry>
            </bibliodiv>
            <bibliodiv label="2.8" status="2" xml:id="sect_2.8">
                <title>Myocardial Segmentation</title>
                <biblioentry xml:id="biblio_Cerqueira_2002">
                    <abbrev>Cerqueira 2002</abbrev>
                    <biblioset relation="journal">
                        <title>Circulation</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Cerqueira MD</personname>
                            </author>
                        </authorgroup>
                        <date>2002</date>
                        <volumenum>105</volumenum>
                        <issuenum>4</issuenum>
                        <pagenums>539</pagenums>
                        <title>AHA Scientific Statement: Standardized Myocardial Segmentation and Nomenclature for Tomographic Imaging of the Heart</title>
                        <biblioid class="doi">10.1161/hc0402.102975</biblioid>
                        <releaseinfo>
                            <remark>Describes 16- and 17-segment models.</remark>
                        </releaseinfo>
                    </biblioset>
                </biblioentry>
                <biblioentry xml:id="biblio_Voigt_2015">
                    <abbrev>Voigt 2015</abbrev>
                    <biblioset relation="journal">
                        <title>Eur Heart J Cardiovasc Imaging</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Voigt JU</personname>
                            </author>
                        </authorgroup>
                        <date>2015</date>
                        <volumenum>16</volumenum>
                        <issuenum>1</issuenum>
                        <pagenums>1-11</pagenums>
                        <title>Definitions for a common standard for 2D speckle tracking echocardiography: consensus document of the EACVI/ASE/Industry Task Force to standardize deformation imaging</title>
                        <biblioid class="doi">10.1093/ehjci/jeu184</biblioid>
                        <releaseinfo>
                            <remark>Describes 16-, 17-, and 18-segment models.</remark>
                        </releaseinfo>
                    </biblioset>
                </biblioentry>
            </bibliodiv>
            <bibliodiv label="2.9" status="2" xml:id="sect_2.9">
                <title>Quantitation of the Left Ventricle</title>
                <biblioentry xml:id="biblio_Schiller_1989">
                    <abbrev>Schiller 1989</abbrev>
                    <biblioset relation="journal">
                        <title>Journal of the American Society of Echocardiography</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Schiller</personname>
                            </author>
                        </authorgroup>
                        <date>Oct 1989</date>
                        <volumenum>2</volumenum>
                        <issuenum>5</issuenum>
                        <pagenums>358-367</pagenums>
                        <title>Recommendations for Quantitation of the Left Ventricle by Two-Dimensional Echocardiography</title>
                    </biblioset>
                </biblioentry>
            </bibliodiv>
            <bibliodiv label="2.10" status="2" xml:id="sect_2.10">
                <title>Cancer Staging</title>
                <biblioentry xml:id="biblio_AJCC">
                    <abbrev>AJCC</abbrev>
                    <author>
                        <orgname>American Joint Committee on Cancer</orgname>
                    </author>
                    <date>2002</date>
                    <edition>Sixth</edition>
                    <title>AJCC Cancer Staging Handbook: From the AJCC Cancer Staging Manual</title>
                    <publisher>
                        <publishername>Springer-Verlag</publishername>
                    </publisher>
                    <biblioid class="isbn">0-387-95270-5</biblioid>
                </biblioentry>
            </bibliodiv>
            <bibliodiv label="2.11" status="2" xml:id="sect_2.11">
                <title>Quantitative Arteriography and Ventriculography</title>
                <biblioentry xml:id="biblio_Sheehan_1986">
                    <abbrev>Sheehan, 1986</abbrev>
                    <biblioset relation="journal">
                        <title>Circulation</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Sheehan FH</personname>
                            </author>
                            <author>
                                <personname>Bolson EL</personname>
                            </author>
                            <author>
                                <personname>Dodge HT</personname>
                            </author>
                            <author>
                                <personname>Mathey DG</personname>
                            </author>
                            <author>
                                <personname>Schofer J</personname>
                            </author>
                            <author>
                                <personname>Woo HW</personname>
                            </author>
                        </authorgroup>
                        <date>1986</date>
                        <volumenum>74</volumenum>
                        <issuenum>2</issuenum>
                        <pagenums>293-305</pagenums>
                        <title>Advantages and applications of the centerline method for characterizing regional ventricular function</title>
                        <biblioid class="doi">10.1161/01.CIR.74.2.293</biblioid>
                    </biblioset>
                </biblioentry>
                <biblioentry xml:id="biblio_Slager_1986">
                    <abbrev>Slager, 1986</abbrev>
                    <biblioset relation="journal">
                        <title>J Am Coll Cardiol.</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Slager CJ</personname>
                            </author>
                            <author>
                                <personname>Hooghoudt TE</personname>
                            </author>
                            <author>
                                <personname>Serruys PW</personname>
                            </author>
                            <author>
                                <personname>Schuurbiers JC</personname>
                            </author>
                            <author>
                                <personname>Reiber JH</personname>
                            </author>
                            <author>
                                <personname>Meester GT</personname>
                            </author>
                            <author>
                                <personname>Verdouw PD</personname>
                            </author>
                            <author>
                                <personname>Hugenholtz PG</personname>
                            </author>
                        </authorgroup>
                        <date>1986</date>
                        <volumenum>6</volumenum>
                        <issuenum>2</issuenum>
                        <pagenums>317-26</pagenums>
                        <title>Quantitative assessment of regional left ventricular motion using endocardial landmarks</title>
                        <biblioid class="doi">10.1016/S0735-1097(86)80498-3</biblioid>
                    </biblioset>
                </biblioentry>
                <biblioentry xml:id="biblio_Kennedy_1970">
                    <abbrev>Kennedy, 1970</abbrev>
                    <biblioset relation="journal">
                        <title>Am Heart J</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Kennedy JW</personname>
                            </author>
                            <author>
                                <personname>Trenholme SE</personname>
                            </author>
                            <author>
                                <personname>Kasser IS</personname>
                            </author>
                        </authorgroup>
                        <date>1970</date>
                        <volumenum>80</volumenum>
                        <issuenum>3</issuenum>
                        <pagenums>343</pagenums>
                        <title>Left ventricular volume and mass from single-plane cineangiocardiogram. A comparison of anteroposterior and right anterior oblique methods</title>
                    </biblioset>
                </biblioentry>
                <biblioentry xml:id="biblio_Dodge_1960">
                    <abbrev>Dodge, 1960</abbrev>
                    <biblioset relation="journal">
                        <title>Am Heart J</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Dodge HT</personname>
                            </author>
                            <author>
                                <personname>Sandler H</personname>
                            </author>
                            <author>
                                <personname>Ballew DW</personname>
                            </author>
                            <author>
                                <personname>Lord JD</personname>
                            </author>
                        </authorgroup>
                        <date>1960</date>
                        <volumenum>60</volumenum>
                        <issuenum>5</issuenum>
                        <pagenums>762</pagenums>
                        <title>The use of biplane angiocardiography for the measurement of left ventricular volume in man</title>
                    </biblioset>
                    <bibliosource>
                        <link xl:href="http://www.sciencedirect.com/science/article/pii/0002870360903598"/>
                    </bibliosource>
                </biblioentry>
                <biblioentry xml:id="biblio_Wynne_1978">
                    <abbrev>Wynne, 1978</abbrev>
                    <biblioset relation="journal">
                        <title>Am J Cardiol</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Wynne J</personname>
                            </author>
                            <author>
                                <personname>Green LH</personname>
                            </author>
                            <author>
                                <personname>Mann T</personname>
                            </author>
                            <author>
                                <personname>Levin D</personname>
                            </author>
                            <author>
                                <personname>Grossman W</personname>
                            </author>
                        </authorgroup>
                        <date>1978</date>
                        <volumenum>41</volumenum>
                        <issuenum>4</issuenum>
                        <pagenums>726</pagenums>
                        <title>Estimation of left ventricular volumes in man from biplane cineangiograms filmed in oblique projections</title>
                    </biblioset>
                </biblioentry>
                <biblioentry xml:id="biblio_Boak_1977">
                    <abbrev>Boak, 1977</abbrev>
                    <biblioset relation="journal">
                        <title>Cathet Cardiovasc Diagn</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Boak, JG</personname>
                            </author>
                            <author>
                                <personname>Bove AA</personname>
                            </author>
                            <author>
                                <personname>Kreulen T</personname>
                            </author>
                            <author>
                                <personname>Spann JF</personname>
                            </author>
                        </authorgroup>
                        <date>1977</date>
                        <volumenum>3</volumenum>
                        <issuenum>3</issuenum>
                        <pagenums>217-30</pagenums>
                        <title>A geometric basis for calculation of right ventricular volume in man</title>
                        <biblioid class="doi">10.1002/ccd.1810030305</biblioid>
                    </biblioset>
                </biblioentry>
                <biblioentry xml:id="biblio_Ferlinz_1977">
                    <abbrev>Ferlinz, 1977</abbrev>
                    <biblioset relation="journal">
                        <title>Am Heart J</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Ferlinz J</personname>
                            </author>
                        </authorgroup>
                        <date>1977</date>
                        <volumenum>94</volumenum>
                        <issuenum>1</issuenum>
                        <pagenums>87-90</pagenums>
                        <title>Measurements of right ventricular volumes in man from single plane cineangiograms. A comparison to the biplane approach</title>
                    </biblioset>
                    <bibliosource>
                        <link xl:href="http://www.sciencedirect.com/science/article/pii/S0002870377803487"/>
                    </bibliosource>
                </biblioentry>
                <biblioentry xml:id="biblio_Graham_1973">
                    <abbrev>Graham, 1973</abbrev>
                    <biblioset relation="journal">
                        <title>Circulation</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Graham TP</personname>
                            </author>
                            <author>
                                <personname>Jarmakani JM</personname>
                            </author>
                            <author>
                                <personname>Atwood GF</personname>
                            </author>
                            <author>
                                <personname>Canent RV</personname>
                            </author>
                        </authorgroup>
                        <date>1973</date>
                        <volumenum>47</volumenum>
                        <issuenum>1</issuenum>
                        <pagenums>144-53</pagenums>
                        <title>Right ventricular volume determinations in children. Normal values and observations with volume or pressure overload</title>
                        <biblioid class="doi">10.1161/01.CIR.47.1.144</biblioid>
                    </biblioset>
                </biblioentry>
                <biblioentry xml:id="biblio_Arcilla_1971">
                    <abbrev>Arcilla, 1971</abbrev>
                    <biblioset relation="journal">
                        <title>Chest</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Arcilla RA</personname>
                            </author>
                            <author>
                                <personname>Tsai P</personname>
                            </author>
                            <author>
                                <personname>Thilenius O</personname>
                            </author>
                            <author>
                                <personname>Ranniger K</personname>
                            </author>
                        </authorgroup>
                        <date>1971</date>
                        <volumenum>60</volumenum>
                        <issuenum>5</issuenum>
                        <pagenums>446</pagenums>
                        <title>Angiographic method for volume estimation of right and left ventricles</title>
                        <biblioid class="doi">10.1378/chest.60.5.446</biblioid>
                    </biblioset>
                </biblioentry>
            </bibliodiv>
            <bibliodiv label="2.12" status="2" xml:id="sect_2.12">
                <title>IVUS</title>
                <biblioentry xml:id="biblio_Mintz_2001">
                    <abbrev>Mintz, 2001</abbrev>
                    <biblioset relation="journal">
                        <title>Journal of the American College of Cardiology</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Mintz GS</personname>
                            </author>
                        </authorgroup>
                        <date>2001</date>
                        <volumenum>37</volumenum>
                        <issuenum>5</issuenum>
                        <pagenums>1478-1492</pagenums>
                        <title>American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS)</title>
                        <biblioid class="doi">10.1016/S0735-1097(01)01175-5</biblioid>
                    </biblioset>
                </biblioentry>
                <biblioentry xml:id="biblio_DiMario_2001">
                    <abbrev>Di Mario, 1998</abbrev>
                    <biblioset relation="journal">
                        <title>European Heart Journal</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Di Mario C</personname>
                            </author>
                        </authorgroup>
                        <date>1998</date>
                        <volumenum>19</volumenum>
                        <issuenum>2</issuenum>
                        <pagenums>207-229</pagenums>
                        <title>Clinical Application and Image Interpretation in Intravascular Ultrasound</title>
                        <biblioid class="doi">10.1053/euhj.1996.0433</biblioid>
                    </biblioset>
                </biblioentry>
                <biblioentry xml:id="biblio_TobisAndYock">
                    <abbrev>Tobis and Yock</abbrev>
                    <authorgroup>
                        <author>
                            <personname>Tobis JM</personname>
                        </author>
                        <author>
                            <personname>Yock PC</personname>
                        </author>
                    </authorgroup>
                    <date>1992</date>
                    <title>Intravascular Ultrasound Imaging</title>
                    <biblioid class="isbn">0443088098</biblioid>
                </biblioentry>
            </bibliodiv>
            <bibliodiv label="2.13" status="2" xml:id="sect_2.13">
                <title>C-RADS CT Colonography Reporting and Data System</title>
                <biblioentry xml:id="biblio_Zalis_2005">
                    <abbrev>Zalis, 2005</abbrev>
                    <biblioset relation="journal">
                        <title>Radiology</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Zalis ME</personname>
                            </author>
                        </authorgroup>
                        <date>2005</date>
                        <volumenum>236</volumenum>
                        <issuenum>1</issuenum>
                        <pagenums>3-9</pagenums>
                        <title>CT Colonography Reporting and Data System: A Consensus Proposal</title>
                        <biblioid class="doi">10.1148/radiol.2361041926</biblioid>
                    </biblioset>
                </biblioentry>
            </bibliodiv>
            <bibliodiv label="2.14" status="2" xml:id="sect_2.14">
                <title>Implants</title>
                <biblioentry xml:id="biblio_Eggli_1998">
                    <abbrev>Eggli, 1998</abbrev>
                    <biblioset relation="journal">
                        <title>J Bone Joint Surg Br</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Eggli S</personname>
                            </author>
                            <author>
                                <personname>Pisan M</personname>
                            </author>
                            <author>
                                <personname>Müller ME</personname>
                            </author>
                        </authorgroup>
                        <date>1998</date>
                        <volumenum>80-B</volumenum>
                        <issuenum>3</issuenum>
                        <pagenums>382-390</pagenums>
                        <title>The value of preoperative planning for total hip arthroplasty</title>
                    </biblioset>
                    <bibliosource>
                        <link xl:href="http://www.bjj.boneandjoint.org.uk/content/80-B/3/382"/>
                    </bibliosource>
                </biblioentry>
            </bibliodiv>
            <bibliodiv label="2.15" status="2" xml:id="sect_2.15">
                <title>LOINC</title>
                <biblioentry xml:id="biblio_LOINC">
                    <abbrev>LOINC</abbrev>
                    <author>
                        <orgname>Regenstrief Institute, Indianapolis</orgname>
                    </author>
                    <date>2014</date>
                    <title>Logical Observation Identifier Names and Codes</title>
                    <bibliosource>
                        <link xl:href="http://loinc.org/"/>
                    </bibliosource>
                </biblioentry>
                <para xml:id="para_e27b6af7-4129-4526-b250-e4ae290145a7">This product includes all or a portion of the LOINC® table, LOINC panels and forms file, LOINC document ontology file, and/or LOINC hierarchies file, or is derived from one or more of the foregoing, subject to a license from Regenstrief Institute, Inc. Your use of the LOINC table, LOINC codes, LOINC panels and forms file, LOINC document ontology file, and LOINC hierarchies file also is subject to this license, a copy of which is available at <link xl:href="http://loinc.org/terms-of-use"/>. The current complete LOINC table, LOINC Users' Guide, LOINC panels and forms file, LOINC document ontology file, and LOINC hierarchies file are available for download at <link xl:href="http://loinc.org/"/>. The LOINC table and LOINC codes are copyright © 1995-2014, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. The LOINC panels and forms file, LOINC document ontology file,
                    and LOINC hierarchies file are copyright © 1995-2014, Regenstrief Institute, Inc. All rights reserved.</para>
                <para xml:id="para_32d856f4-3e42-40ed-9391-01d4b4c28f31">The LOINC table (in all formats), LOINC panels and forms file, LOINC document ontology file, and LOINC hierarchies are provided "as is." Any express or implied warranties are disclaimed, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose.</para>
                <para xml:id="para_a4826285-c5a2-41f4-9613-a5ed6d6ad7ae">A small portion of the LOINC table may include content (e.g., survey instruments) that is subject to copyrights owned by third parties. Such content has been mapped to LOINC terms under applicable copyright and terms of use. Notice of such third party copyright and license terms would need to be included if such content is included.</para>
            </bibliodiv>
            <bibliodiv label="2.16" status="2" xml:id="sect_2.16">
                <title>UCUM</title>
                <biblioentry xml:id="biblio_UCUM">
                    <abbrev>UCUM</abbrev>
                    <author>
                        <orgname>Regenstrief Institute, Indianapolis</orgname>
                    </author>
                    <date>2013</date>
                    <title>Unified Code for Units of Measure</title>
                    <bibliosource>
                        <link xl:href="http://unitsofmeasure.org/"/>
                    </bibliosource>
                </biblioentry>
                <para xml:id="para_10e9b576-9f74-4056-9dae-4ae188aa3b31">This product includes all or a portion of the UCUM table, UCUM codes, and UCUM definitions or is derived from it, subject to a license from Regenstrief Institute, Inc. and The UCUM Organization. Your use of the UCUM table, UCUM codes, UCUM definitions also is subject to this license, a copy of which is available at <link xl:href="http://unitsofmeasure.org/"/>. The current complete UCUM table, UCUM Specification are available for download at <link xl:href="http://unitsofmeasure.org/"/>. The UCUM table and UCUM codes are copyright © 1995-2013, Regenstrief Institute, Inc. and the Unified Codes for Units of Measures (UCUM) Organization. All rights reserved.</para>
                <para xml:id="para_ea6907be-79f4-473d-9f1d-b831034b0247">The UCUM table (in all formats), UCUM definitions, and specification are provided "as is." Any express or implied warranties are disclaimed, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose.</para>
            </bibliodiv>
            <bibliodiv label="2.17" status="2" xml:id="sect_2.17">
                <title>Anesthesia Quality Institute Schema</title>
                <biblioentry xml:id="biblio_AQISchema">
                    <abbrev>AQI Schema</abbrev>
                    <author>
                        <orgname>Anesthesia Quality Institute, Schaumburg, IL</orgname>
                    </author>
                    <date>2015/07/30</date>
                    <title>Anesthesia Quality Institute Schema</title>
                    <bibliosource>
                        <link xl:href="http://www.aqihq.org/qcdrDataSample/prodFiles/2018%20Files/AQISchDoc/default.html"/>
                    </bibliosource>
                </biblioentry>
                <para xml:id="para_d5afcc5e-558e-4606-9229-050c207a9d39">Used by permission of the Anesthesia Quality Institute (AQI) (<link xl:href="http://www.aqihq.org/"/>), established by the American Society of Anesthesiologists (ASA).</para>
            </bibliodiv>
            <bibliodiv label="2.18" status="2" xml:id="sect_2.18">
                <title>Point-of-Care Medical Device Nomenclature</title>
                <para xml:id="para_f3f65cde-1097-47c8-a6c5-7969e464556b">Extracts of ISO/IEEE 11073 reprinted by permission of IEEE, 3 Park Avenue, New York, NY 10016-5997 USA. Copyright by IEEE. <link xl:href="http://standards.ieee.org/"/>.</para>
                <para xml:id="para_0795806a-ccd6-453e-be9f-253b4d0b43cd">Under license from IEEE, the term codes and descriptions of the ISO/IEEE 11073 Nomenclature are available at no cost through the Rosetta Terminology Mapping Management System of the U.S. National Institute of Standards and Technology. <link xl:href="http://rtmms.nist.gov/rtmms/index.htm"/>
                </para>
                <biblioentry xml:id="biblio_ISOIEEE_11073_10101">
                    <abbrev>ISO/IEEE 11073-10101</abbrev>
                    <author>
                        <orgname>ISO/IEEE</orgname>
                    </author>
                    <date>2004</date>
                    <title>Health informatics - Point-of-care medical device communication - Nomenclature</title>
                </biblioentry>
                <biblioentry xml:id="biblio_ISOIEEE_11073_10101a">
                    <abbrev>ISO/IEEE 11073-10101a</abbrev>
                    <author>
                        <orgname>ISO/IEEE</orgname>
                    </author>
                    <date>2015</date>
                    <title>Health informatics - Point-of-care medical device communication - Nomenclature Amendment 1: Additional Definitions</title>
                </biblioentry>
                <biblioentry xml:id="biblio_ISOIEEE_11073_10102">
                    <abbrev>ISO/IEEE 11073-10102</abbrev>
                    <author>
                        <orgname>ISO/IEEE</orgname>
                    </author>
                    <date>2015</date>
                    <date/>
                    <title>Health informatics - Point-of-care medical device communication - Annotated ECG - Nomenclature</title>
                </biblioentry>
            </bibliodiv>
            <bibliodiv label="2.19" status="2" xml:id="sect_2.19">
                <title>SNOMED Clinical Terms</title>
                <para xml:id="para_b12ff9ab-63d4-49c6-8b07-c9cb7157230b">This DICOM Standard incorporates SNOMED CT® International Edition 2021/07/31, used by permission of SNOMED International. SNOMED CT®, was originally created by The College of American Pathologists (CAP). SNOMED International was formerly known as the International Health Terminology Standards Development <foreignphrase xml:lang="en-GB">Organisation</foreignphrase> (IHTSDO).</para>
                <para xml:id="para_b8c0e400-55f0-43b6-9bba-d98b7e1dc32d">The SNOMED CT terms used in this Standard (the SNOMED CT DICOM Subset) are the subject of a licensing agreement between NEMA and SNOMED International that allows the use of this defined subset in DICOM conformant applications without further license or payment of fee. Any use of SNOMED CT beyond the terms published in the DICOM Standard is subject to SNOMED CT licensing rules, which may include a fee. For further information about SNOMED CT licensing, go to <link xl:href="http://www.snomed.org/snomed-ct/get-snomed"/> or contact SNOMED International at <link xl:href="mailto:info@snomed.org">info@snomed.org</link>.</para>
                <para xml:id="para_0fd01632-8e25-482c-9c6c-bc91416e68e6">This DICOM Standard incorporates various veterinary terms from the SNOMED CT VetSCT extension, used by permission of the Veterinary Terminology Services Laboratory (VTSL) (<link xl:href="http://vtsl.vetmed.vt.edu/"/>). These terms were previously included in SNOMED CT but have since been inactivated as moved elsewhere.</para>
                <biblioentry xml:id="biblio_SNOMED">
                    <abbrev>SNOMED</abbrev>
                    <author>
                        <orgname>SNOMED International</orgname>
                    </author>
                    <date/>
                    <title>SNOMED CT Systematized Nomenclature of Medicine - Clinical Terms</title>
                </biblioentry>
            </bibliodiv>
            <bibliodiv label="2.20" status="2" xml:id="sect_2.20">
                <title>Prostate Reporting Terminology and Nomenclature</title>
                <para xml:id="para_cdfe3ded-7367-499d-b0fa-d5392c898a6c">The Prostate Imaging and Report and Data System Version 2 (PI-RADS) is a joint effort of the European Society of Urogenital Radiology, the American College of Radiology and the AdMeTech Foundation.</para>
                <biblioentry xml:id="biblio_PIRADS">
                    <abbrev>PI-RADS</abbrev>
                    <biblioset relation="journal">
                        <title>Eur Urol</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Weinreb JC</personname>
                            </author>
                            <author>
                                <personname>Barentsz JO</personname>
                            </author>
                            <author>
                                <personname>Choyke PL</personname>
                            </author>
                            <author>
                                <personname>Cornud F</personname>
                            </author>
                            <author>
                                <personname>Haider MA</personname>
                            </author>
                            <author>
                                <personname>Macura KJ</personname>
                            </author>
                            <author>
                                <personname>Margolis, D</personname>
                            </author>
                            <author>
                                <personname>Schnall, MD</personname>
                            </author>
                            <author>
                                <personname>Shtern, F</personname>
                            </author>
                            <author>
                                <personname>Tempany, CM.</personname>
                            </author>
                            <author>
                                <personname>Thoeny, HC</personname>
                            </author>
                            <author>
                                <personname>Verma, S</personname>
                            </author>
                        </authorgroup>
                        <date>2016/01</date>
                        <volumenum>69</volumenum>
                        <issuenum>1</issuenum>
                        <pagenums>16-40</pagenums>
                        <title>PI-RADS Prostate Imaging - Reporting and Data System: 2015, Version 2</title>
                        <biblioid class="doi">10.1016/j.eururo.2015.08.052</biblioid>
                        <bibliosource>
                            <link xl:href="http://www.europeanurology.com/article/S0302-2838%2815%2900848-9/"/>
                        </bibliosource>
                    </biblioset>
                </biblioentry>
                <note>
                    <para xml:id="para_9f46fcec-ffde-445a-8216-89a6716b9cab">PI-RADS is also available from the following source: <itemizedlist>
                            <listitem>
                                <para xml:id="para_5d3b28fa-b951-4a5d-8492-bde3ada78d1a">American College of Radiology: <link xl:href="http://www.acr.org/~/media/ACR/Documents/PDF/QualitySafety/Resources/PIRADS/PIRADS%20V2.pdf"/>
                                </para>
                            </listitem>
                        </itemizedlist>
                    </para>
                </note>
                <biblioentry xml:id="biblio_PIRADS21">
                    <abbrev>PI-RADS v2.1</abbrev>
                    <biblioset relation="journal">
                        <title>Eur Urol</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Turkbey B</personname>
                            </author>
                            <author>
                                <personname>Rosenkrantz AB</personname>
                            </author>
                            <author>
                                <personname>Haider MA</personname>
                            </author>
                            <author>
                                <personname>Padhani AR</personname>
                            </author>
                            <author>
                                <personname>Villeirs G</personname>
                            </author>
                            <author>
                                <personname>Macura KJ</personname>
                            </author>
                            <author>
                                <personname>Tempany, CM</personname>
                            </author>
                            <author>
                                <personname>Choyke PL</personname>
                            </author>
                            <author>
                                <personname>Cornud F</personname>
                            </author>
                            <author>
                                <personname>Margolis, D</personname>
                            </author>
                            <author>
                                <personname>Thoeny, HC</personname>
                            </author>
                            <author>
                                <personname>Verma, S</personname>
                            </author>
                            <author>
                                <personname>Barentsz JO</personname>
                            </author>
                            <author>
                                <personname>Weinreb JC</personname>
                            </author>
                        </authorgroup>
                        <date>2019/09</date>
                        <volumenum>76</volumenum>
                        <issuenum>3</issuenum>
                        <pagenums>340–351</pagenums>
                        <title>Prostate Imaging Reporting and Data System Version 2.1: 2019 Update of Prostate Imaging Reporting and Data System Version 2</title>
                        <biblioid class="doi">10.1016/j.eururo.2019.02.033</biblioid>
                        <bibliosource>
                            <link xl:href="http://www.europeanurology.com/article/S0302-2838(19)30180-0/abstract"/>
                        </bibliosource>
                    </biblioset>
                </biblioentry>
                <biblioentry xml:id="biblio_ProstateEuConcensus">
                    <abbrev>Prostate Eu Concensus</abbrev>
                    <biblioset relation="journal">
                        <title>Eur Urol</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Dickinson L</personname>
                            </author>
                            <author>
                                <personname>Ahmed HU.</personname>
                            </author>
                            <author>
                                <personname>Allen C</personname>
                            </author>
                            <author>
                                <personname>Barentsz JO</personname>
                            </author>
                            <author>
                                <personname>Carey B</personname>
                            </author>
                            <author>
                                <personname>Futterer JJ</personname>
                            </author>
                            <author>
                                <personname>Heijmink SW</personname>
                            </author>
                            <author>
                                <personname>Hoskin PJ</personname>
                            </author>
                            <author>
                                <personname>Kirkham A</personname>
                            </author>
                            <author>
                                <personname>Padhani AR</personname>
                            </author>
                        </authorgroup>
                        <date>2011</date>
                        <volumenum>59</volumenum>
                        <issuenum>4</issuenum>
                        <pagenums>477-94</pagenums>
                        <title>Magnetic resonance imaging for the detection, localisation, and characterisation of prostate cancer: recommendations from a European consensus meeting</title>
                        <biblioid class="doi">10.1016/j.eururo.2010.12.009</biblioid>
                        <bibliosource>
                            <link xl:href="http://www.europeanurology.com/article/S0302-2838(10)01187-5/"/>
                        </bibliosource>
                    </biblioset>
                </biblioentry>
                <biblioentry xml:id="biblio_ESURGuidelines">
                    <abbrev>ESUR Guidelines</abbrev>
                    <biblioset relation="journal">
                        <title>Eur Radiol</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Barentsz JO</personname>
                            </author>
                            <author>
                                <personname>Richenberg J</personname>
                            </author>
                            <author>
                                <personname>Clements R</personname>
                            </author>
                            <author>
                                <personname>Choyke P</personname>
                            </author>
                            <author>
                                <personname>Verma S</personname>
                            </author>
                            <author>
                                <personname>Villeirs G</personname>
                            </author>
                            <author>
                                <personname>Rouviere O</personname>
                            </author>
                            <author>
                                <personname>Logager V</personname>
                            </author>
                            <author>
                                <personname>Fütterer JJ</personname>
                            </author>
                        </authorgroup>
                        <date>2012/04</date>
                        <volumenum>22</volumenum>
                        <issuenum>4</issuenum>
                        <pagenums>746-57</pagenums>
                        <title>ESUR prostate MR guidelines 2012</title>
                        <biblioid class="doi">10.1007/s00330-011-2377-y</biblioid>
                        <bibliosource>
                            <link xl:href="http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3297750/">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3297750/</link>
                        </bibliosource>
                    </biblioset>
                </biblioentry>
                <biblioentry xml:id="biblio_Rozenkrantz2013">
                    <abbrev>Rozenkrantz 2013</abbrev>
                    <biblioset relation="journal">
                        <title>Radiology</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Rosenkrantz AB</personname>
                            </author>
                            <author>
                                <personname>Kim S</personname>
                            </author>
                            <author>
                                <personname>Lim RP</personname>
                            </author>
                            <author>
                                <personname>Hindman N</personname>
                            </author>
                            <author>
                                <personname>Deng FM</personname>
                            </author>
                            <author>
                                <personname>Babb JS</personname>
                            </author>
                            <author>
                                <personname>Taneja SS</personname>
                            </author>
                        </authorgroup>
                        <date>2013/11</date>
                        <volumenum>269</volumenum>
                        <issuenum>2</issuenum>
                        <pagenums>482–492</pagenums>
                        <title>Prostate cancer localization using multiparametric MR imaging: comparison of Prostate Imaging Reporting and Data System (PI-RADS) and Likert scales</title>
                        <biblioid class="doi">10.1148/radiol.13122233</biblioid>
                        <bibliosource>
                            <link xl:href="http://dx.doi.org/10.1148/radiol.13122233">http://dx.doi.org/10.1148/radiol.13122233</link>
                        </bibliosource>
                    </biblioset>
                </biblioentry>
                <biblioentry xml:id="biblio_Kuru2013">
                    <abbrev>Kuru 2013</abbrev>
                    <biblioset relation="journal">
                        <title>BJU Int</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Kuru TH</personname>
                            </author>
                        </authorgroup>
                        <date>2013</date>
                        <volumenum>112</volumenum>
                        <issuenum>5</issuenum>
                        <pagenums>568–577</pagenums>
                        <title>Definitions of terms, processes and a minimum dataset for transperineal prostate biopsies: a standardization approach of the Ginsburg Study Group for Enhanced Prostate Diagnostics</title>
                        <biblioid class="doi">10.1111/bju.12132</biblioid>
                        <bibliosource>
                            <link xl:href="http://onlinelibrary.wiley.com/doi/10.1111/bju.12132/full">http://onlinelibrary.wiley.com/doi/10.1111/bju.12132/full</link>
                        </bibliosource>
                    </biblioset>
                </biblioentry>
            </bibliodiv>
            <bibliodiv label="2.21" status="2" xml:id="sect_2.21">
                <title>Imaging Agent Administration Concepts</title>
                <para xml:id="para_32ec87c5-c9ae-4fdb-81b5-c196f92c7380">Injector and modality manufacturers use the CiA 425 CANopen standard for communication and synchronization between devices.</para>
                <biblioentry xml:id="biblio_CiA425CANopen">
                    <abbrev>CiA 425 CANopen</abbrev>
                    <author>
                        <orgname>CANopen</orgname>
                    </author>
                    <date>30 October 2010</date>
                    <title>CiA 425 Draft Standard Proposal, Application profile for medical diagnostic add-on modules Part 2: Injector, Version: 2.1.0</title>
                </biblioentry>
            </bibliodiv>
            <bibliodiv label="2.22" status="2" xml:id="sect_2.22">
                <title>CAD-RADS™ Terminology and Nomenclature</title>
                <para xml:id="para_b98d4deb-a7b3-49f7-be76-30a3dd8cd91d">A portion of the terminology used within the CT/MR Cardiovascular Analysis Report is derived from CAD-RADS™.</para>
                <biblioentry xml:id="biblio_CADRADS">
                    <abbrev>CAD-RADS™</abbrev>
                    <biblioset relation="journal">
                        <title>Journal of Cardiovascular Computed Tomography</title>
                    </biblioset>
                    <biblioset relation="article">
                        <authorgroup>
                            <author>
                                <personname>Cury RC</personname>
                            </author>
                            <author>
                                <personname>et al</personname>
                            </author>
                        </authorgroup>
                        <date>2016</date>
                        <volumenum>10</volumenum>
                        <pagenums>269-81</pagenums>
                        <title>CAD-RADS™ Coronary Artery Disease – Reporting and Data System. An expert consensus document of the Society of Cardiovascular Computed Tomography (SCCT), the American College of Radiology (ACR) and the North American Society for Cardiovascular Imaging (NASCI). Endorsed by the American College of Cardiology.</title>
                        <biblioid class="doi">10.1016/j.jcct.2016.04.005</biblioid>
                    </biblioset>
                    <bibliosource>
                        <link xl:href="http://www.journalofcardiovascularct.com/article/S1934-5925(16)30048-X/"/>
                    </bibliosource>
                </biblioentry>
            </bibliodiv>
        </bibliography>
    </chapter>
    <chapter label="3" status="1" xml:id="chapter_3">
        <title>Definitions</title>
        <para xml:id="para_f1b16969-20b4-46c4-8a57-a2f8d6e5e387">For the purposes of this Standard the following definitions apply.</para>
        <glossary>
            <title/>
            <glossdiv label="3.1" status="2" xml:id="sect_3.1">
                <title>Codes and Controlled Terminology Definitions</title>
                <para xml:id="para_0486a070-c8c5-459d-8748-50ba181f01e0">The following definitions are commonly used in this Part of the DICOM Standard:</para>
                <glossentry xml:id="glossentry_BaselineContextGroupIdentifier" xreflabel="Baseline Context Group Identifier (BCID)">
                    <glossterm>Baseline Context Group Identifier</glossterm>
                    <acronym>BCID</acronym>
                    <glossdef>
                        <para xml:id="para_c7c77b22-ec7f-443f-a7c3-3b292bd0328a">Identifier that specifies the suggested Context Group for a Code Sequence Attribute.</para>
                        <para xml:id="para_2f623054-f71b-4bef-bddc-289bd5f790bd">See <olink targetdoc="PS3.3" targetptr="table_5.6-1" xrefstyle="select: docname label quotedtitle"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_BaselineTemplateIdentifier" xreflabel="Baseline Template Identifier (BTID)">
                    <glossterm>Baseline Template Identifier</glossterm>
                    <acronym>BTID</acronym>
                    <glossdef>
                        <para xml:id="para_4d341e60-6b5e-49af-a5f4-6db76947d5e8">Identifier that specifies a Template suggested to be used in the creation of a set of Content Items.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_CodingScheme" xreflabel="Coding Scheme">
                    <glossterm>Coding Scheme</glossterm>
                    <glossdef>
                        <para xml:id="para_0576e070-1b8f-458c-a994-299303d1b1c7">Dictionary (lexicons) of concepts (terms) with assigned codes and well defined meanings.</para>
                        <note>
                            <para xml:id="para_afb7f486-6cba-4706-ba84-b7ac8f4af2e2">Examples of Coding Schemes include SNOMED and LOINC.</para>
                        </note>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_ContextGroup" xreflabel="Context Group">
                    <glossterm>Context Group</glossterm>
                    <glossdef>
                        <para xml:id="para_1f2dfd0b-b432-4fe6-a326-7c2a331bc79b">A set of coded concepts defined by a Mapping Resource forming a set appropriate to use in a particular context.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_ContextGroupVersion" xreflabel="Context Group Version">
                    <glossterm>Context Group Version</glossterm>
                    <glossdef>
                        <para xml:id="para_d1ebf453-eb1b-4692-8005-7ebc96ece195">Version of a Context Group.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_ContextID" xreflabel="Context ID (CID)">
                    <glossterm>Context ID</glossterm>
                    <acronym>CID</acronym>
                    <glossdef>
                        <para xml:id="para_1885a739-eae9-413a-b4e8-9620a386b19b">Identifier of a Context Group.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_DefinedContextGroupIdentifier" xreflabel="Defined Context Group Identifier (DCID)">
                    <glossterm>Defined Context Group Identifier</glossterm>
                    <acronym>DCID</acronym>
                    <glossdef>
                        <para xml:id="para_cdfbdf21-8df7-4c7f-9bdd-67cfa278d18e">Identifier that specifies the Context Group for a Code Sequence Attribute that shall be used.</para>
                        <para xml:id="para_fa36fe54-600e-4dd8-86fe-6383569e0bd0">See <olink targetdoc="PS3.3" targetptr="table_5.6-1" xrefstyle="select: docname label quotedtitle"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_DefinedTemplateIdentifier" xreflabel="Defined Template Identifier (DTID)">
                    <glossterm>Defined Template Identifier</glossterm>
                    <acronym>DTID</acronym>
                    <glossdef>
                        <para xml:id="para_6970224b-de48-422c-bf7b-93f55b6de69a">Identifier that specifies a Template that shall be used in the creation of a set of Content Items.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_DICOMContentMappingResource" xreflabel="DICOM Content Mapping Resource (DCMR)">
                    <glossterm>DICOM Content Mapping Resource</glossterm>
                    <acronym>DCMR</acronym>
                    <glossdef>
                        <para xml:id="para_2b5051f1-6dae-4d3e-a79c-08298fe57af6">A Mapping Resource that defines Templates and Context Groups for use in DICOM IODs.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_ExtensibleContextGroup" xreflabel="Extensible Context Group">
                    <glossterm>Extensible Context Group</glossterm>
                    <glossdef>
                        <para xml:id="para_d53236fc-950c-42e7-9f59-fe21c709efd6">Context Group that may be extended by a particular application by inclusion of additional concepts.</para>
                        <para xml:id="para_7e80fe9c-18af-4503-b6c9-9f19e49307db">See <olink targetdoc="PS3.3" targetptr="table_5.6-1" xrefstyle="select: docname label quotedtitle"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_ExtensibleTemplate" xreflabel="Extensible Template">
                    <glossterm>Extensible Template</glossterm>
                    <glossdef>
                        <para xml:id="para_c7a846f5-c432-4585-96bb-3b41576d2fd2">A Template that may be extended by a particular application by inclusion of additional Content Items beyond those specified in the Template.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_MappingResource" xreflabel="Mapping Resource">
                    <glossterm>Mapping Resource</glossterm>
                    <glossdef>
                        <para xml:id="para_1188d4b9-9f27-4102-b5b4-12ebe0a24628">A resource that defines context-dependent usage constraints (i.e., Value Set or Relationship Type restrictions) for Attributes. A resource that specifies the mapping of the content of an external controlled terminology to the components of a message standard.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_NonExtensibleContextGroup" xreflabel="Non-Extensible Context Group">
                    <glossterm>Non-Extensible Context Group</glossterm>
                    <glossdef>
                        <para xml:id="para_66de5d23-c4f1-4e4e-8679-f3c94cc27797">Context Group whose defined set of concepts shall not be extended by an application.</para>
                        <para xml:id="para_a14eeada-a8cf-4790-9a5b-3b26fe274da8">See <olink targetdoc="PS3.3" targetptr="table_5.6-1" xrefstyle="select: docname label quotedtitle"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_NonExtensibleTemplate" xreflabel="Non-Extensible Template">
                    <glossterm>Non-Extensible Template</glossterm>
                    <glossdef>
                        <para xml:id="para_2cafb152-6a8b-40c8-8c22-facf27740179">A Template that specifies the exact set of Content Items and corresponding Value Sets that shall be used and that shall not be extended by an application.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_RelationshipType" xreflabel="Relationship Type">
                    <glossterm>Relationship Type</glossterm>
                    <glossdef>
                        <para xml:id="para_307f585f-6dcc-4a6f-a19d-01f8d56e2bb3">The association between two Concepts. Examples: "HAS PROPERTIES", "CONTAINS", "INFERRED FROM".</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_RootTemplate" xreflabel="Root Template">
                    <glossterm>Root Template</glossterm>
                    <glossdef>
                        <para xml:id="para_3a68ef2c-d814-4905-a4af-43d9923055c9">A Template whose first Content Item is a CONTAINER Content Item intended to be encoded in the top level Data Set of a SOP Instance. I.e., the root node of the Content Tree.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_Template" xreflabel="Template">
                    <glossterm>Template</glossterm>
                    <glossdef>
                        <para xml:id="para_4fbbe304-f9f5-493b-861d-3f61416b643e">A pattern that describes the Content Items, Value Types, Relationship Types and Value Sets that may be used in part of a Structured Report Content Tree, or in other Content Item constructs, such as Acquisition Context or Protocol Context. Analogous to a Module of an Information Object Definition.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_TemplateID" xreflabel="Template ID (TID)">
                    <glossterm>Template ID</glossterm>
                    <acronym>TID</acronym>
                    <glossdef>
                        <para xml:id="para_0e693a15-fcab-4509-bb38-042b0d6c7dcd">Identifier of a Template.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_ValueSet" xreflabel="Value Set">
                    <glossterm>Value Set</glossterm>
                    <glossdef>
                        <para xml:id="para_c1a9bb3c-5876-4e47-9707-78119fcdcf1e">The allowed values of a Code Sequence Attribute in a given context. Specified either as one or more individual values or by reference to a Context Group.</para>
                    </glossdef>
                </glossentry>
            </glossdiv>
            <glossdiv label="3.2" status="2" xml:id="sect_3.2">
                <title>Information Object Definitions</title>
                <para xml:id="para_295dc731-c6ae-4b90-983e-69f415c94847">This Part of the Standard makes use of the following terms defined in <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>:</para>
                <glossentry xml:id="glossentry_AttributeValue" xreflabel="Attribute Value">
                    <glossterm>Attribute Value</glossterm>
                    <glossdef>
                        <para xml:id="para_7288764f-d201-49bc-a809-0129f31523de">
                            <olink targetdoc="PS3.3" targetptr="glossentry_AttributeValue" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_CodedEntryValue" xreflabel="Coded Entry Value">
                    <glossterm>Coded Entry Value</glossterm>
                    <glossdef>
                        <para xml:id="para_5443405a-776d-470b-a52f-9c88b38c9198">
                            <olink targetdoc="PS3.3" targetptr="glossentry_CodedEntryValue" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_CodeSequenceAttribute" xreflabel="Code Sequence Attribute">
                    <glossterm>Code Sequence Attribute</glossterm>
                    <glossdef>
                        <para xml:id="para_e2b93a62-bc0b-4f0d-8584-a742c0207a53">
                            <olink targetdoc="PS3.3" targetptr="glossentry_CodeSequenceAttribute" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
            </glossdiv>
            <glossdiv label="3.3" status="2" xml:id="sect_3.3">
                <title>Contrast Administration Definitions</title>
                <glossentry xml:id="glossentry_ImagingAgent">
                    <glossterm>Imaging Agent</glossterm>
                    <glossdef>
                        <para xml:id="para_5bd10f9a-939b-49a5-a85e-c4732d1e5956">A substance administered to improve the imaging of specific organs, tissues, diseases and physiological functions. Adapted from Wikipedia <link xl:href="http://en.wikipedia.org/wiki/Imaging_agent"/>.</para>
                        <note>
                            <orderedlist>
                                <listitem>
                                    <para xml:id="para_679b8676-fd8d-434c-9bd6-e7d4d7840248">Imaging agents include iodinated X-Ray and gadolinium-based MR contrast agents.</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_71784955-8ead-4a0c-814f-6fbc38d6ca76">Saline flush is not an imaging agent but may be administered in conjunction with imaging agents.</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_d505d6b8-7761-4b26-888e-ecf66f63aa6a">Air used as a negative contrast agent is an imaging agent.</para>
                                </listitem>
                            </orderedlist>
                        </note>
                    </glossdef>
                </glossentry>
            </glossdiv>
            <glossdiv label="3.4" status="2" xml:id="sect_3.4">
                <title>DICOM Introduction and Overview Definitions</title>
                <para xml:id="para_43fa3788-d238-4c0e-becf-c25ceb35d193">This Part of the Standard makes use of the following terms defined in <olink targetdoc="PS3.1" targetptr="PS3.1" xrefstyle="select: labelnumber"/>:</para>
                <glossentry xml:id="glossentry_ServiceObjectPairClass" xreflabel="Service-Object Pair Class (SOP Class)">
                    <glossterm>Service-Object Pair Class</glossterm>
                    <acronym>SOP Class</acronym>
                    <glossdef>
                        <para xml:id="para_aa8fc553-543f-41a3-a70b-689e52eae642">
                            <olink targetdoc="PS3.1" targetptr="glossentry_ServiceObjectPairClass" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
            </glossdiv>
            <glossdiv label="3.5" status="2" xml:id="sect_3.5">
                <title>DICOM Service Class Definitions</title>
                <para xml:id="para_6c6b342d-4e14-4a0f-9715-0a712a330800">This Part of the Standard makes use of the following terms defined in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>:</para>
                <glossentry xml:id="glossentry_ServiceObjectPairInstance" xreflabel="Service-Object Pair Instance (SOP Instance)">
                    <glossterm>Service-Object Pair Instance</glossterm>
                    <acronym>SOP Instance</acronym>
                    <glossdef>
                        <para xml:id="para_f004cee7-d646-4c89-9039-f4969d3e1f0e">
                            <olink targetdoc="PS3.4" targetptr="glossentry_ServiceObjectPairInstance" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
            </glossdiv>
            <glossdiv label="3.6" status="2" xml:id="sect_3.6">
                <title>DICOM Data Structures and Encoding</title>
                <para xml:id="para_4959c9c7-0b5f-4f5a-9348-c2eca70accc2">This Part of the Standard makes use of the following terms defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>:</para>
                <glossentry xml:id="glossentry_DataSet" xreflabel="Data Set">
                    <glossterm>Data Set</glossterm>
                    <glossdef>
                        <para xml:id="para_e087df5a-24aa-4f39-aa97-e2065cc6a1ec">
                            <olink targetdoc="PS3.5" targetptr="glossentry_DataSet" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_Item" xreflabel="Item">
                    <glossterm>Item</glossterm>
                    <glossdef>
                        <para xml:id="para_d96b9550-4f3e-471b-89ad-baf1549409eb">
                            <olink targetdoc="PS3.5" targetptr="glossentry_Item" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_Value" xreflabel="Value">
                    <glossterm>Value</glossterm>
                    <glossdef>
                        <para xml:id="para_815f56c5-7da7-426e-8028-ccef7ac99b0e">
                            <olink targetdoc="PS3.5" targetptr="glossentry_Value" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
            </glossdiv>
            <glossdiv label="3.7" status="2" xml:id="sect_3.7">
                <title>Radiotherapy</title>
                <glossentry xml:id="glossentry_MonitorUnits" xreflabel="Monitor Units">
                    <glossterm>Monitor Units</glossterm>
                    <acronym>MU</acronym>
                    <glossdef>
                        <para xml:id="para_b884e1e7-615a-4b11-b9c8-cdfd40d619c2">A unit of radiation output used to quantify a Meterset. See <olink targetdoc="PS3.3" targetptr="sect_C.36.1.1.3" xrefstyle="select: docname label quotedtitle"/>.</para>
                    </glossdef>
                </glossentry>
            </glossdiv>
            <glossdiv label="3.8" status="2" xml:id="sect_3.8">
                <title>Structured Report Definitions</title>
                <para xml:id="para_3e40b406-97ef-4935-b2b1-a5db74994665">This Part of the Standard makes use of the following terms defined in <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>:</para>
                <glossentry>
                    <glossterm>Content Item</glossterm>
                    <glossdef>
                        <para xml:id="para_df1acdc5-66c4-41a0-a9b1-d8c44f574e63">
                            <olink targetdoc="PS3.3" targetptr="glossentry_ContentItem" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry>
                    <glossterm>Content Tree</glossterm>
                    <glossdef>
                        <para xml:id="para_692387f3-f985-41cd-beb5-f57ecf471aa4">
                            <olink targetdoc="PS3.3" targetptr="glossentry_ContentTree" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
            </glossdiv>
        </glossary>
    </chapter>
    <chapter label="4" status="1" xml:id="chapter_4">
        <title>Symbols and Abbreviations</title>
        <para xml:id="para_b44ecf8c-4252-4aa8-a1b4-620da0c1043c">The following symbols and abbreviations are used in this Part of the Standard.</para>
        <variablelist>
            <varlistentry>
                <term>ACR</term>
                <listitem>
                    <para xml:id="para_3cfddd65-c2bb-4c0e-8cbe-5db7068eee96">American College of Radiology</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>ASE</term>
                <listitem>
                    <para xml:id="para_d36573f2-7b7f-4918-9acc-b0e3f8b32f29">American Society of Echocardiography</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>BCID</term>
                <listitem>
                    <para xml:id="para_2e7ae836-0298-4cb6-bd6d-245cc2324737">Baseline Context Group ID</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>BTID</term>
                <listitem>
                    <para xml:id="para_4542397f-1733-43d0-86a0-c76bfe576f5e">Baseline Template ID</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>CAP</term>
                <listitem>
                    <para xml:id="para_2b60ceaf-548d-4018-b904-8d94922a9b51">College of American Pathologists</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>Chest CAD</term>
                <listitem>
                    <para xml:id="para_b5535f67-58b2-43b1-b2dd-19cc804ed4c9">Computer-Aided Detection and/or Computer-Aided Diagnosis for chest radiography</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>CNAME</term>
                <listitem>
                    <para xml:id="para_b4f1255a-3015-48f7-b676-941c74ed614b">Context Group Name</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>Colon CAD</term>
                <listitem>
                    <para xml:id="para_aee52c4b-27d2-4abe-9341-fd7791244420">Computer-Aided Detection and/or Computer-Aided Diagnosis for colon radiography</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>CSV</term>
                <listitem>
                    <para xml:id="para_38ba706f-d94e-489d-9706-3044851dc5a9">Comma-separated Values</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>DCID</term>
                <listitem>
                    <para xml:id="para_4c6909f2-26b9-4591-9c5b-cf5c39462bea">Defined Context Group ID</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>DCMR</term>
                <listitem>
                    <para xml:id="para_5897bc45-ae23-4929-862a-1440524d36b5">DICOM Content Mapping Resource</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>DICOM</term>
                <listitem>
                    <para xml:id="para_39b281af-b268-40c9-89dc-e64a6e182ffd">Digital Imaging and Communications in Medicine</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>DT</term>
                <listitem>
                    <para xml:id="para_8d524da8-1731-4836-bdc1-ad19cea8b22a">Defined Term</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>DTID</term>
                <listitem>
                    <para xml:id="para_13fbbcb1-ce42-41f7-8f07-15f5cea63225">Defined Template ID</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>EV</term>
                <listitem>
                    <para xml:id="para_c672298f-a591-43e6-aa03-09cf6820bf97">Enumerated Value</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>FHIR</term>
                <listitem>
                    <para xml:id="para_ad7147bb-38b9-4d28-9985-955f607e5f02">Fast Healthcare Interoperability Resources</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>HTML</term>
                <listitem>
                    <para xml:id="para_df6a73cf-fb80-49c8-876e-57a11b48369a">HyperText Markup Language</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>IHE</term>
                <listitem>
                    <para xml:id="para_8d3d622c-11bb-4459-96ee-c23796bc6508">Integrating the Healthcare Enterprise</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>IHE SVS</term>
                <listitem>
                    <para xml:id="para_6b14acc6-7961-49ea-9948-a65067cd2576">IHE Sharing Value Sets</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>JSON</term>
                <listitem>
                    <para xml:id="para_b1d54e5a-e78e-486c-a69f-d5c328cd571b">JavaScript Object Notation</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>Mammography CAD</term>
                <listitem>
                    <para xml:id="para_07bc188b-b981-4dda-a22c-807e170e5728">Computer-Aided Detection and/or Computer-Aided Diagnosis for Mammography</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>MPPS</term>
                <listitem>
                    <para xml:id="para_38954efe-4aff-4bf4-afef-c05a96affb56">Modality Performed Procedure Step</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>NEMA</term>
                <listitem>
                    <para xml:id="para_c6e7736a-f43a-4e7a-9f26-d54cc11d860a">National Electrical Manufacturers Association</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>OWL</term>
                <listitem>
                    <para xml:id="para_00b39bdb-f1af-4ce9-a4ae-d42ed9f79504">Web Ontology Language</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>RDSR</term>
                <listitem>
                    <para xml:id="para_a307e3e1-41c3-4c22-a466-6f7f361cda32">Radiation Dose Structured Report</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>RECIST</term>
                <listitem>
                    <para xml:id="para_5b289f1d-182f-4a33-800a-3da3e16f029d">Response Evaluation Criteria In Solid Tumors</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>SNOMED</term>
                <listitem>
                    <para xml:id="para_d5ed1c0b-09d3-4e16-9757-2b6fdef5014a">Systematized Nomenclature of Medicine</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>TNAME</term>
                <listitem>
                    <para xml:id="para_9f943633-b527-4dde-987b-cbf400047d78">Template Name</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>UCUM</term>
                <listitem>
                    <para xml:id="para_d03ab753-cdf0-44fa-9970-9358fe1f2e83">Unified Code for Units of Measure</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>WHO</term>
                <listitem>
                    <para xml:id="para_ce2e22d3-4dae-42b2-85ed-cba63e7c7a07">World Health Organization</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>XML</term>
                <listitem>
                    <para xml:id="para_04c39439-6147-4fcb-a748-1d8cccdc8438">eXtensible Markup Language</para>
                </listitem>
            </varlistentry>
        </variablelist>
        <para xml:id="para_52e4c70a-1213-4260-a48d-ada7740fd416">The following upper-case abbreviations represent specific Attributes:</para>
        <variablelist spacing="compact">
            <varlistentry>
                <term>CM</term>
                <listitem>
                    <para xml:id="para_dcf27712-4d5f-4152-9f41-8b644afc7c06">Code Meaning (0008,0104)</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>CSD</term>
                <listitem>
                    <para xml:id="para_8ebf7e8a-e145-4022-ae00-02e228ce1cf9">Coding Scheme Designator (0008,0102)</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>CSV</term>
                <listitem>
                    <para xml:id="para_82745947-6b5b-4533-b024-86ef4379c875">Coding Scheme Version (0008,0103)</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>CV</term>
                <listitem>
                    <para xml:id="para_321d4796-063a-4b85-bd4f-b19cf4f2d892">Code Value (0008,0100) or Long Code Value (0008,0119) or URN Code Value (0008,0120)</para>
                </listitem>
            </varlistentry>
        </variablelist>
    </chapter>
    <chapter label="5" status="1" xml:id="chapter_5">
        <title>Conventions</title>
        <para xml:id="para_f46faad8-7b81-403f-9e37-b53efb767d85">Terms listed in <xref linkend="chapter_3" xrefstyle="template:Section %n"/> are capitalized throughout the document.</para>
    </chapter>
    <chapter label="6" status="1" xml:id="chapter_6">
        <title>Form of Template Specifications</title>
        <para xml:id="para_6047f3aa-43ec-47a2-8a96-8ea0ace4f2e1">Templates are patterns that specify the Concept Names, Requirements, Conditions, Value Types, Value Multiplicity, Value Set restrictions, Relationship Types and other attributes of Content Items for a particular application.</para>
        <para xml:id="para_f2c21b5c-1410-4661-984b-5aa01a081524">An IOD may specify that particular Standard Templates shall be used or may be used to define or constrain the content of a Content Item construct. A Content Item construct includes a coded concept name and one of several types of coded values. Content Item constructs are used in:</para>
        <itemizedlist>
            <listitem>
                <para xml:id="para_baf89140-be0d-4a59-a189-5fe7441cb6d3">the main Data Set and recursively nested Content Sequences (0040,A730) of the <olink targetdoc="PS3.3" targetptr="sect_C.17.3" xrefstyle="select: title"/>
                </para>
            </listitem>
            <listitem>
                <para xml:id="para_07e6406c-6c08-46f4-b335-29ef8498ef07">the Acquisition Context Sequence (0040,0555) of the <olink targetdoc="PS3.3" targetptr="sect_C.7.6.14" xrefstyle="select: title"/>,</para>
            </listitem>
            <listitem>
                <para xml:id="para_9414c996-71d5-4923-b939-dc7420176aa5">the Protocol Context Sequence (0040,0440) and Content Item Modifier Sequence (0040,0441) of the <olink targetdoc="PS3.3" targetptr="sect_C.4.10" xrefstyle="select: title"/>, <olink targetdoc="PS3.3" targetptr="sect_C.4.15" xrefstyle="select: title"/>, and others.</para>
            </listitem>
            <listitem>
                <para xml:id="para_1e9813f8-b102-43ce-9fe6-99638771806d">the Specimen Preparation Step Content Item Sequence (0040,0612) of the <olink targetdoc="PS3.3" targetptr="sect_C.7.6.22" xrefstyle="select: title"/>.</para>
            </listitem>
        </itemizedlist>
        <para xml:id="para_4dc19f60-377e-403f-a9e5-6ad6e058f70f">
            <xref linkend="chapter_A" xrefstyle="template:Annex %n"/> and <xref linkend="chapter_C" xrefstyle="template:Annex %n"/> of this Part define Standard Templates.</para>
        <note>
            <para xml:id="para_933a6789-e2b9-4d25-8d2c-446ab3d57d28">Standard Extended and Private Templates may be defined by implementers of the Standard. The rules for definition of Standard Extended and Private SR Templates are similar to the rules for definition of Standard Extended and Private SOP Classes. One row of a Template table corresponds to one row of a Module table in a <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/> IOD.</para>
        </note>
        <para xml:id="para_4dee010a-3f17-4960-8907-2f58760cc9b8">Each Standard Template is specified by a Template table in this Part. Each Template table specifies exactly one Template, corresponding to a pattern of content within a Content Item construct.</para>
        <para xml:id="para_f4b8e5fd-f9da-47ea-8a11-ab10909d490f">Each Template table identifies whether the order of Content Items is significant or not significant. SOP Instances whose content is based on a Template where the order is significant shall encode the top level Content Items in the order they are specified in the Template, and the subsidiary Content Items under each parent item in the order they are specified, and so on for each Nesting Level. The significance of the order applies only to the Template itself; subsidiary included Templates may have a different order significance.</para>
        <note>
            <para xml:id="para_9720547b-39de-424b-9c5d-21210987ce4d">Even if a Template specifies that the order is not significant, there may be significance to the order in which Content Items are encoded in a SOP Instance. For example, CONTAINER Content Items with a Continuity of Content (0040,A050) Value of CONTINUOUS encode Content Items in narrative sequence, and procedure logs encode Content Items in time order.</para>
        </note>
        <para xml:id="para_942d344a-6182-4d71-8e82-8785152ed57f">The Content Items from subsidiary Templates may be intermingled if and only if the parent and subsidiary all specify that the order is not significant. This permits later refactoring into reusable Templates.</para>
        <para xml:id="para_e79c3ce2-cd3a-42d5-bd53-547ccdca4b23">The range of concepts and the options that are permitted in a family of SR Documents vary inversely with the level of constraint that is applied by the corresponding SR Template. The more narrow the range of concepts and the more restricted the options permitted by a Template, the more predictable the content of the SR Documents will be.</para>
        <note>
            <orderedlist>
                <listitem>
                    <para xml:id="para_a9c8b7aa-89fc-4e66-82d7-a0da12039157">A very specific Template defines a family of SR Documents that are very similar to each other. They have a narrow range of content options (e.g., high level of constraint of Content Item values; use of CODE or NUM with Defined Context Group Identifiers) and their content is therefore highly predictable. A very general (e.g., permissive or broad) Template defines a family of SR Documents that may differ considerably from one another. They have a broader range of content options (e.g., low level of constraint of Content Item values; use of TEXT and relatively little restriction of Content Item values) and their content is less predictable.</para>
                </listitem>
                <listitem>
                    <para xml:id="para_c2a4b89c-fa3f-47de-a1a2-6bbb3049de7d">The degree of interoperability that may be achieved with a family of SR Documents generated from a Template may be determined intentionally and precisely at a desired level by appropriate Template design to achieve the necessary degree of predictability of SR Document contents.</para>
                </listitem>
            </orderedlist>
        </note>
        <section label="6.1" status="2" xml:id="sect_6.1">
            <title>Template Table Field Definition</title>
            <para xml:id="para_d9cf7f1e-8d38-4fbe-a4fd-ee45d13b7bb7">SR Templates are described using tables of the following form:</para>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_b3d69357-1213-4405-8699-7eaf97386123">
                            <emphasis role="bold">(Non-) Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Order:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_69420395-2519-4244-a15b-577bcf0ff284">
                            <emphasis role="bold">(Non-) Significant</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Root:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_0339c1bd-3af1-4b88-90ca-be48f41f35da">
                            <emphasis role="bold">Yes or No</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="TID &lt;#&gt;" rules="all">
                <caption>&lt;SR Context Template Name&gt;</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1b54d105-c2a2-44e4-8bf1-e34002b03580"/>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b34b5872-1502-4555-afc1-f256f6dd03d1">NL</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f0e35a22-02f7-4c61-a084-f3fbc094ee8a">Rel with Parent</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c1a29237-e8b3-41f4-a72b-400b74b2c586">VT</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cb2c076b-b957-4120-a434-0763242a7ad6">Concept Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f3ed3c64-7029-468b-a110-78271e8a6b3f">VM</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_57e898ed-0380-408f-867d-23fa7850e767">Req Type</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3d1a2e6e-02fa-4e72-9c27-8df3db494305">Condition</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_56dfc23e-f639-4722-a9e2-7769a3290281">Value Set Constraint</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c5e35e9e-3cba-4201-bc41-fa37f18543ed">1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_62c212a0-2502-4c75-94e7-b6433231f846"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_663bd0b8-ab5c-4522-9d06-8764b384eaa8"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9cc77ed4-0f41-4287-95a0-3e2526601b6c"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e276cad0-7c67-44a6-b957-9fc771f937ab"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_758cee2e-5a5d-4ea2-b2bb-807bca9d2883"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_76d7084b-8eef-4c44-a024-4c2a0bbae7dd"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fc7d9940-ddc7-4ffc-8e6c-6a5c1d4b1c75"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6ab0b09b-de60-4b80-8531-b9e57f770b3d"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_edff2388-6518-4546-a38d-55016d0cb17f">2</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f84740b0-f9d4-4251-a236-ede91bb72ad9"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c0913786-635a-440b-9f5a-e3bac24b727b"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_edb5de13-8416-453d-81be-1d51f097eefc"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_80d4c888-97fb-46e0-8bbe-bc27681c8a1f"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_16e1b091-34ac-4ddd-a016-ae11ef01f7a2"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3ed8b128-76a4-4ac0-8d90-26713d9a544f"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d0cb5dcb-999d-4b68-962a-ac7b1e26bb59"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8043edf8-c5ef-4014-9528-8ea497ed23e4"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6bc53612-2863-4d0c-9812-ff8c69b8ce7f">3</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b8b3a26a-7e37-4659-83af-38a785c579fe"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c0ff6534-78f6-4bf5-8315-24c51bc8b0b9"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c9b9cbcb-bb0c-4747-8e67-16b771d16733"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_51eb1bf3-a7b6-4fda-91c5-8901dda08926"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0389fcc1-7454-46a5-ab2b-128a3fd9a325"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f0d39756-ef6a-45a7-82ec-45c14889d640"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6bd860d0-0aff-4b62-8a45-ffe973e58d24"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_faa5a9f0-8fa3-49ff-9d8e-0cbc8a46e2d9"/>
                        </td>
                    </tr>
                </tbody>
            </table>
            <para xml:id="para_bedde946-68f4-493e-97c6-cb37b46c4821">Acquisition Context Templates are described using tables of the following form:</para>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_4a2d6f93-3990-4114-9147-dab3fd9621ee">
                            <emphasis role="bold">(Non-) Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Order:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_5f91e7e3-4052-453e-a1b9-608fbdc1d695">
                            <emphasis role="bold">(Non-) Significant</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="TID &lt;#&gt;" rules="all">
                <caption>&lt;Acquisition Context Template Name&gt;</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1af59433-b620-4484-bd35-61c2353a5437"/>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_21880cca-8d77-4dec-989a-f27cd98a78ab">VT</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_95042042-0f67-4d40-b5b8-dbabe2c2b0af">Concept Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5b8db9ce-e062-4e49-8534-ff834eb0d955">VM</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_38296919-d58b-42d3-8a09-9174505892f4">Req Type</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dc1ab41e-b1b2-46b4-898d-7d8cb2f1251c">Condition</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ff65334a-192c-480e-8542-9245311916a8">Value Set Constraint</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_34880411-674a-43b3-9607-a3b11a5914cf">1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_94996382-011e-4afd-92fc-8541c73aac99"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1ea49941-dcbd-4d43-be99-9e1bd627b73c"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4be2d7a4-d19f-401d-8a44-53cef31070e8"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_26e0af3c-c9a4-46ee-91ce-746e28ee33a5"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8579033f-953e-4c61-8065-6a3ff775c33e"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4dd0c898-8c02-461c-b64a-0285a7bb9f60"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ceb010ec-37c6-4332-aa7e-b99fe031dca8">2</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_27acc6c6-6034-48fb-abd1-d9d7e48364c8"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_be5b41ce-718f-4f97-8ddb-ee6eaafab5b2"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_96493519-ca60-4e80-a9b2-e4bde051d25f"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e57a41d0-54bb-456d-bb4f-df361b998c23"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c906ec8c-1a52-4705-925e-103c4e92f305"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_15c5775f-a196-4e6d-8745-706992d4c19f"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7089a309-dade-43b1-8629-a3f9f17d86ed">3</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b62969fe-f86f-464f-8dca-93b689776819"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a520fb39-9262-433f-a7fa-db239dee2029"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_db04bb62-dd97-483c-bf41-7ddbbdac5eef"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f7a186ba-441c-4a58-a7a0-702dac2bb958"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7a31b6e9-deee-45db-9595-3fa0be04d9f4"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b8706ee2-a4cc-4eb5-81c6-fe669f91a55a"/>
                        </td>
                    </tr>
                </tbody>
            </table>
            <para xml:id="para_8650a17e-2963-4bd2-9c62-888dbc912c63">Protocol Context Templates are described using tables of the following form:</para>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_cf741931-0cd8-44b4-a06f-f574f908a75d">
                            <emphasis role="bold">(Non-) Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Order:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_908af981-d8a7-4608-8cae-bd0d8222333a">
                            <emphasis role="bold">(Non-) Significant</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="TID &lt;#&gt;" rules="all">
                <caption>&lt;Protocol Context Template Name&gt;</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c0431069-aad1-48b7-b541-f201cb28964d"/>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b08f9fd0-420a-4a96-a855-8e009483319d">NL</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1843e5fe-2349-490f-b792-ccfb006ff26b">VT</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_53701567-49d3-4392-8295-da13a02631e8">Concept Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ff65e4a0-6492-429b-815c-da3b6f287683">VM</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c61d33ea-05d4-4966-8beb-6329e66ba704">Req Type</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fffcff24-c6d7-40c9-be00-6da63b8525cb">Condition</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eb2cc8f7-c038-443d-9a8c-b210c95ff0a7">Value Set Constraint</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2f6d7c17-a287-4805-b859-dde77ae0d356">1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7b685bb2-6683-4721-b3f7-c49c0e6bd894"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3ae2da47-9757-4593-b7a1-a3a6c86b6cae"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d930f1d7-e24e-4650-bb66-0435b2daa7b4"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6d36efc3-5480-49a2-8f3f-71b3167ff960"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_287d9071-fdd3-4f5e-9660-17920583e8ad"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_95d09882-d7d3-464c-b575-16f4a2734e46"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_24299820-5db0-427b-969c-3481763939a4"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e87be008-808e-4acb-9ed2-9ac42d36e57d">2</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_836cb7e4-1a10-4ffb-9f12-51c808543daf"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_654ed81f-84f4-46f3-8fa4-bdd5178eb761"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ffd61a2b-fa71-452b-b6ef-d0394fc28e5e"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6e1411eb-c395-4435-a1d5-c5be3552391e"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bd477906-cc6c-4d4c-a0fc-62abebc2e708"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ca629fe9-24c0-4575-8d80-055fc0adb516"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0401fb2e-3ac3-4424-9c6b-2027592324c6"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4eae1510-fe86-4826-8ca6-f94402e07cf6">3</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8344f916-ed00-484e-bc75-e7998c3ccd1a"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_93d34e9c-bd87-4310-a275-59f87a150f2f"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2fb585a5-d6ab-4949-bcc8-7f75c0af0c1c"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_707d10dd-83f7-419e-827c-07dec72c32eb"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8a1d5fe8-a063-4960-aebd-d07b966d6525"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9cdce1e1-8480-48c8-bc51-966fd9ee3d5c"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_683df49d-a398-4c6b-b507-5ead44c02599"/>
                        </td>
                    </tr>
                </tbody>
            </table>
            <para xml:id="para_50a246e1-f886-4c10-9090-dbbccdd1c830">The semantics of the fields (columns) of Template tables are defined by subsections of this Section.
                A row of a Template table specifies either one Content Item or inclusion of another Template that may specify any number of Content Items (see <xref linkend="sect_6.2.3" xrefstyle="select: label"/> for definition of "Included Templates").
                Each Template table is named by a title, identified by a TID number and further explained by a description such as explanation of Template contents, purpose and use cases.</para>
            <para xml:id="para_481a1c1e-26fb-467b-bcf4-6ec94fa721ae">A separate table of the following form may be used to describe individual rows, i.e., Content Items:</para>
            <para xml:id="para_63094502-262d-4592-a1f0-a918637daf3e">
                <emphasis role="bold">Content Item Descriptions</emphasis>
            </para>
            <informaltable frame="box" rules="all">
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b7f56c48-d2e4-4e3a-8683-59c781c61c96">Row 1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_96beff75-53cf-4979-9a2f-a0199ee26daf"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8ecf7053-82c1-4d54-af72-be4e18de3eff">Rows 2, 3</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f5d3f172-9d70-4512-a7a1-d4c2a77f88e3"/>
                        </td>
                    </tr>
                </tbody>
            </informaltable>
            <para xml:id="para_4f7e10b6-78ea-44a6-9217-9e44a1f48a8c">The first column contains a reference to the row(s) of the Template table using the respective Row Number(s) (see <xref linkend="sect_6.1.1" xrefstyle="select: label"/>), e.g., "Row 1" refers to the row identified as the first row of the Template table and "Rows 2, 3" refers to the rows identified as second and third row of the Template table. When referring to multiple rows, the Row Numbers are fully enumerated. The second column contains the description of the referenced row(s).</para>
            <note>
                <orderedlist>
                    <listitem>
                        <para xml:id="para_290da71d-6342-4af9-b2e7-86d8dc593674">Ranges, such as "Rows 1-3", or other kind of abbreviations are not used.</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_7489ae4d-e3c8-436d-affe-c9b29fed538c">It is not necessary to describe all rows of a Template table in this additional table.</para>
                    </listitem>
                </orderedlist>
            </note>
            <para xml:id="para_af17e937-530c-4328-9d47-e34e9b31ea3b">The following conventions are defined for the form of references to coded concepts, Context Groups and Templates.</para>
            <para xml:id="para_d6fc379f-6254-446c-b740-38c2685697e3">Code Meanings are enclosed in quotation marks (for example "cm"). Code Values and Coding Scheme Designators are not enclosed in quotation marks unless a comma occurs in the string.</para>
            <para xml:id="para_cc142160-60d2-4132-84ab-642fbf20e6ad">References to coded concepts take the following form:</para>
            <itemizedlist>
                <listitem>
                    <para xml:id="para_62eda4f3-47aa-449a-8b20-e3b06a294ee1">EV or DT (CV, CSD, "CM")</para>
                    <para xml:id="para_49567316-a32b-4cee-a9db-5f4ff9127bec">e.g., an Enumerated Value with only CV, CSD, and CM defined is represented as follows: EV (CV, CSD, "CM"), for example EV (76752008, SCT, "Breast").</para>
                </listitem>
                <listitem>
                    <para xml:id="para_59a35bca-c874-49be-8dd9-73a71fda3229">MemberOf { BCID or DCID (CID) CNAME } MemberOf selects one term from the specified Context Group.</para>
                </listitem>
            </itemizedlist>
            <para xml:id="para_5a1f20db-df29-4a45-924b-2df9103715ad">If reference to a specific Coding Scheme version is required, it takes the following form:</para>
            <itemizedlist>
                <listitem>
                    <para xml:id="para_e2986f2e-184c-4cfc-a4ec-27a06f7b9c02">EV or DT (CV, CSD [CSV], "CM")</para>
                    <para xml:id="para_65e24919-6768-4181-b1a1-4449140ecff3">e.g., DT (MA.II.A.5.4A, BI [4.0], "4A - Low suspicion").</para>
                </listitem>
            </itemizedlist>
            <para xml:id="para_394ed553-4d5c-4567-b0de-6b6e111c978b">References to Context Groups take the following form:</para>
            <itemizedlist>
                <listitem>
                    <para xml:id="para_111361c1-7ff1-4e08-938c-7fdf530b80e8">BCID or DCID (CID) CNAME</para>
                    <para xml:id="para_d6f8d40b-003c-44b4-8e42-5a62426400f4">e.g., Defined Context Group Identifier 5000 is represented as follows: DCID (5000) Language.</para>
                </listitem>
            </itemizedlist>
            <para xml:id="para_665d3905-0c9d-4699-8b74-b90b27cb57b8">References to Templates take the following form:</para>
            <itemizedlist>
                <listitem>
                    <para xml:id="para_66df3b12-db24-489f-bdbd-5587789c3f26">BTID or DTID (TID) TNAME</para>
                    <para xml:id="para_39d482c5-c7c4-4795-8a6f-f7f0b843c50d">e.g., Baseline Template Identifier 1000 is represented as follows: BTID (1000) Quotation.</para>
                </listitem>
            </itemizedlist>
            <section label="6.1.1" status="3" xml:id="sect_6.1.1">
                <title>Row Number</title>
                <para xml:id="para_97f1fb18-6b32-43d2-a276-852c5deb9b7b">Each row of a Template table is denoted by a Row Number. The first row is numbered 1 and subsequent rows are numbered in ascending order with increments of 1. This number denotes a row for convenient description as well as reference in conditions.</para>
                <note>
                    <para xml:id="para_60c48535-9ff9-4aa4-b477-89354a197539">When templates are amended by adding a new row that is inserted into an existing Template table, i.e., not added after the last row, an alphabetic suffix is appended to the Row Number of the preceding row. E.g., a Row Number of “2a” or “2b” is used to insert the new row between row “2” and “3”.</para>
                </note>
                <para xml:id="para_2f24cf16-62e8-42b7-93ef-522723bb4279">The Row Number of a Content Item in a Template may or may not be the same as the ordinal position of the corresponding Sequence Item (representing the Content Item) in a Content Sequence (0040,A730), depending on the number of times the Content Item is repeated.</para>
                <para xml:id="para_71def2d5-0260-4b3a-8caf-f69974e0e68d">The Content Item specified in the first row of a Template table may be of any Value Type. Specifically, it is not constrained to be a CONTAINER.</para>
            </section>
            <section label="6.1.2" status="3" xml:id="sect_6.1.2">
                <title>Nesting Level (NL)</title>
                <para xml:id="para_e819f516-b50b-4bc6-b756-cb602773e5c1">When a parent-child relationship is present between two Content Items, the parent is deemed to be the Source Content Item and the child is deemed to be the Target Content Item; see <olink targetdoc="PS3.3" targetptr="sect_C.17.3.2.4" xrefstyle="select: docname label title"/>.</para>
                <para xml:id="para_e7929772-3878-4fcf-944e-b04cce3cdef3">The Nesting Level of Content Items is denoted by "&gt;" symbols, one per level of nesting below the initial Source Content Item (of the Template) in a manner similar to the depiction of nested Sequences of Items in Modules Tables in <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>. When it is necessary to specify the Target Content Item(s) of a relationship, they are specified in the row(s) immediately following the corresponding Source Content Item. The Nesting Level of a Target Content Item is one greater than the Nesting Level of the corresponding (parent) Source Content Item. The Content Item specified in row 1 of a Template table is at the top level (i.e., no "&gt;" symbol is ever present in the NL field for the first Content Item in the table).</para>
                <para xml:id="para_a2cde5ba-96d0-4d67-bbce-31952605129e">Acquisition Context Templates have no Nesting Level field. Protocol Context and UPS Processing Parameter Templates allow a single Nesting Level implemented through the Content Item Modifier Sequence (see <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>).</para>
            </section>
            <section label="6.1.3" status="3" xml:id="sect_6.1.3">
                <title>Relationship with Source Content Item (Parent)</title>
                <para xml:id="para_67dfebaa-6751-437f-8638-86f4ad8e1237">Relationship Type and by-value or by-reference constraints, if defined, are specified in this field, as described <xref linkend="table_6.1.3-1" xrefstyle="select: label nopage"/>.</para>
                <para xml:id="para_a8f8bdeb-501b-46d2-8c9f-210caebd4eab">Relationship Type and Mode are specified for each row that specifies a Target Content Item.</para>
                <para xml:id="para_c8b08b42-90ff-4fbc-a252-64e4f5b21709">Relationship Type and Mode may also be specified when another Template is included, either "top-down" or "bottom-up" or both (i.e., in the "INCLUDE Template" row of the calling Template, or in all rows of the included Template, or in both places).
                    There shall be no conflict between the Relationship Type and Mode of a row that includes another Template and the Relationship Type and Mode of the rows of the included Template.
                    See <xref linkend="sect_6.2.3" xrefstyle="select: label"/> for further description of "Included Templates".</para>
                <note>
                    <para xml:id="para_ab4a794b-6189-4ada-a822-3b5324599519">SR IODs specify Enumerated Values for Relationship Types. If a Relationship Type other than one of the Defined Terms for Relationship Type (0040,A010) is specified in a Private SOP Class, there is a significant risk to interoperability. Documentation accompanying Templates for Private SOP Classes should define any Relationship-type extensions in the manner that the Standard Relationship Types are defined in <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>.</para>
                </note>
                <para xml:id="para_a028582f-7218-4cbf-a008-6c0c123556d4">Acquisition Context and Protocol Context Templates have no Relationship field.</para>
                <table frame="box" label="6.1.3-1" rules="all" xml:id="table_6.1.3-1">
                    <caption>Syntax of Relationship Constraints</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ef954ab0-69bf-4e44-8e1a-10a8e226c127">Expression</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d4a1bf1f-b978-4dbb-a414-52deb00ed348">Definition</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1c4fe04-c595-49a8-bb88-f983aa9ada56">RTYPE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c01bf1af-8139-47c0-84a9-abced6710a45">Relationship Mode is by-value and Relationship Type is RTYPE. For example, "INFERRED FROM".</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac19dcc7-095c-493a-a49f-c632f85e65bb">R-RTYPE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_672ce3d4-9275-46c9-958e-59a7effe0bc2">Relationship Mode is by-reference and Relationship Type is RTYPE. For example, "R-INFERRED FROM".</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="6.1.4" status="3" xml:id="sect_6.1.4">
                <title>Value Type (VT)</title>
                <para xml:id="para_ab283c4d-c45a-4d44-a80d-ee0b21cfc303">The Value Type field specifies the SR Value Type of the Content Item or conveys the word "INCLUDE" to indicate that another Template is to be included (substituted for the row).
                    See <xref linkend="sect_6.2.3" xrefstyle="select: label"/> for further description of "Included Templates".</para>
            </section>
            <section label="6.1.5" status="3" xml:id="sect_6.1.5">
                <title>Concept Name</title>
                <para xml:id="para_26ac7ff3-dcce-4eca-8aec-f09882699653">Any constraints on the Concept Name are specified in the Concept Name field as defined or enumerated coded entries, or as baseline or defined Context Group Identifiers.
                    Alternatively, when the VT field is "INCLUDE", the Concept Name field specifies the Template to be included.
                    See <xref linkend="sect_6.2.3" xrefstyle="select: label"/> for further description of "Included Templates".</para>
                <para xml:id="para_f1cc3c5b-66be-48c7-9fad-21a5e2b70dab">The absence of an entry in the Concept Name field means that any code may be used, from any Coding Scheme, including codes from private Coding Schemes.</para>
            </section>
            <section label="6.1.6" status="3" xml:id="sect_6.1.6">
                <title>Value Multiplicity (VM)</title>
                <para xml:id="para_44e0d269-3daa-4f9a-86bd-d5e98f9f9474">The VM field indicates the number of times that either a Content Item of the specified pattern or an included Template may appear in this position. Table 6.1.6-1 specifies the values that are permitted in this field.</para>
                <table frame="box" label="6.1.6-1" rules="all" xml:id="table_6.1.6-1">
                    <caption>Permitted Values for VM</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_21ef4eca-3c16-48e8-80cf-697ccedf8432">Expression</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f9989e9b-fe5b-474a-b425-087781aa0afe">Definition</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c6ad4fd8-ed2c-45b6-8c96-e1129d32cb39">i (where 'i' represents an integer)</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7831e0a3-5da7-44e7-8157-ef2e0bce0bc4">Exactly i occurrences, where i&gt;=1. E.g., when i=1 there shall be one occurrence of the Content Item in this position.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce411b2b-a203-48d0-87ad-78de2716b3f0">i-j (where 'i' and 'j' represent integers)</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff0c591b-8054-4960-9691-621de5776c2a">From i to j occurrences, where i and j are &gt;=1 and j&gt;i.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_23ef2a98-6bbe-409b-96b0-11fc0a8b7270">i-n (where 'i' and 'n' represent integers)</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_708cc9c8-544f-4215-9d92-82bb560ab3c1">i or more occurrences, where i&gt;=1.</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="6.1.7" status="3" xml:id="sect_6.1.7">
                <title>Requirement Type</title>
                <para xml:id="para_82e8dab2-5409-41c6-8ce5-591b706bc2c6">The Requirement Type field specifies the requirements on the presence or absence of the Content Item or included Template.</para>
                <note>
                    <para xml:id="para_f8ecd3ab-8983-401e-88a3-e0173c9324f4">There is typically no need to specify Requirement Type separately for SCU and SCP of the SR SOP Classes, because the SCP is required to support the entire content of any SR Document it receives. Therefore, for SR SOP Classes, Requirement Type effectively only applies to the SCU.</para>
                </note>
                <para xml:id="para_55f7d4a8-1ece-44b1-9863-5696b5f6cb27">The following symbols are used:</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>M</term>
                        <listitem>
                            <para xml:id="para_85a40c4c-f4e7-4702-974c-c5c741eef642">Mandatory. Shall be present. An empty Measured Value Sequence (0040,A300) is not permitted when unknown, only for failures. See <xref linkend="sect_6.1.7.1" xrefstyle="select: label"/>.</para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>MC</term>
                        <listitem>
                            <para xml:id="para_31154a70-a83f-4486-987b-9555fbe4bd4a">Mandatory Conditional. Shall be present if the specified condition is satisfied. An empty Measured Value Sequence (0040,A300) is not permitted when unknown, only for failures. See <xref linkend="sect_6.1.7.1" xrefstyle="select: label"/>.</para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>U</term>
                        <listitem>
                            <para xml:id="para_e20ba64b-55be-4ae9-8bfd-1a2544cc05a1">User Option. May or may not be present.</para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>UC</term>
                        <listitem>
                            <para xml:id="para_f49e8f52-9ddc-45fc-b810-18ef03e24ce2">User Option Conditional. May not be present. May be present according to the specified condition.</para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <note>
                    <para xml:id="para_91412e8f-d06c-4250-94a2-54681e6a8816">There is an interaction between the VM and the Requirement Type with respect to the number of times that a Content Item (or included Template) may actually be present, as follows:</para>
                    <informaltable frame="box" rules="all">
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_6745ccef-c094-4ddf-9444-820d8b401162">Req Type</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f1130be1-2b49-4940-a8dc-84b82bf35992">VM</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f443d34e-caab-4193-b51e-58dc0d96812b">Actual number of occurrences in the Content Tree</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_fadc81a4-0b17-4013-8f1f-7ce93be30987">M or MC</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_283f6aa2-f25f-4c41-bc5c-f9a588f947c6">1</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2e6bcde0-c328-4144-9150-a554db0af1b2">1</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_101c5aa2-ccf2-4e80-a972-2231e4c8dcf2">M or MC</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_14dafe07-1f1b-4b9b-957b-b042d8d39f25">1-n</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e43697a6-55c1-4b90-8208-ca259efecb8e">1 to n</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2f040750-351d-4092-b036-74dc8ead9162">U or UC</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_90df3ca3-d573-46a0-9a40-12c875b57ff0">1</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_af3ac0cd-44e1-4fdd-817a-324aac41e5bb">0 or 1</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_fb2a337e-d27c-4364-a1a3-adbdaa953c93">U or UC</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_50d705a8-76c6-4c1e-b12d-46e1fe9a3b11">1-n</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b7b2be29-18ed-4c66-9ba1-a6be8fd44e56">0 to n</para>
                                </td>
                            </tr>
                        </tbody>
                    </informaltable>
                </note>
                <section label="6.1.7.1" status="4" xml:id="sect_6.1.7.1">
                    <title>Requirement Type for Numeric Content Items in Structured Reports</title>
                    <para xml:id="para_4c2b1937-5c82-4ebf-a6bc-b6a6e8ef7d9c">
                        <olink targetdoc="PS3.3" targetptr="sect_C.18.1" xrefstyle="select: docname label title"/> permits the Measured Value Sequence (0040,A300), which contains the Numeric Value (0040,A30A) and Measurement Units Code Sequence (0040,08EA) to be zero length.</para>
                    <note>
                        <para xml:id="para_2f36cc0c-cb9f-4ba2-97ac-7679c57de6f8">This does not apply to the <olink targetdoc="PS3.3" targetptr="sect_10.2" xrefstyle="select: docname label title"/>, which does not permit an empty Measured Value Sequence (0040,A300) nor does it include a Numeric Value Qualifier Code Sequence (0040,A301).</para>
                    </note>
                    <para xml:id="para_e24663fe-73bf-47f8-954a-e8373d7f8a77">The unknown state shall be distinguished from valid arithmetic or device or algorithm failure related states (in which cases a numeric string that complies with the <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/> Value Representation for DS cannot be created).</para>
                    <para xml:id="para_52b77199-2531-49e0-acb2-432f9cc1a3e7">If the Template Requirement Type is M or MC, then:</para>
                    <itemizedlist>
                        <listitem>
                            <para xml:id="para_ccd7609d-f755-4cab-ace2-8210ae9c0e1f">A zero length Measured Value Sequence (0040,A300) is permitted for any of the reasons listed in <xref linkend="sect_CID_43" xrefstyle="select: labelnumber quotedtitle nopage"/>
                            </para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_ff781dda-961a-4957-a803-605112eb579b">A zero length Measured Value Sequence (0040,A300) is not permitted for any of the reasons listed in <xref linkend="sect_CID_44" xrefstyle="select: labelnumber quotedtitle nopage"/>, or any other semantically equivalent reason</para>
                        </listitem>
                    </itemizedlist>
                    <note>
                        <para xml:id="para_8a82cf06-7268-4f9b-8172-8d3c4ee9647f">The intent of the foregoing is to discourage an implementer from thwarting the requirements of the Template. Sending meaningless values, such as a value of zero, when zero is not a realistic value, is also not encouraged.</para>
                    </note>
                </section>
            </section>
            <section label="6.1.8" status="3" xml:id="sect_6.1.8">
                <title>Condition</title>
                <para xml:id="para_a0fc5df4-a133-4cf9-a994-b7aeef7261b6">The Condition field specifies any conditions upon which presence or absence of the Content Item or its values depends. This field specifies any Concept Name(s) or values upon which there are dependencies.</para>
                <para xml:id="para_8c852b55-78cd-488c-860a-eecb83e7dc3c">References in Condition statements to coded concepts or values, whether to select a Content Item to test or to specify a value to test against, are of the form (CV, CSD, "CM"). As is always the case for coded entries, the matching is performed against CV and CSD, irrespective of the string value of CM.</para>
                <para xml:id="para_8482ce0a-c278-4d96-8fd4-6108cd6cb6b6">References may also be made to Row Numbers (e.g., to specify exclusive OR conditions that span multiple rows of a Template table). When referring to multiple rows, the Row Numbers have to be fully enumerated, e.g., "Rows 1, 2, 3". When referring to a single row, the singular form is used, e.g., "Row 2".</para>
                <note>
                    <para xml:id="para_7b50ef7c-de6b-4c71-bd4b-94c9d49d6704">Ranges, such as "Rows 1-3", or other kind of abbreviations, are not used.</para>
                </note>
                <para xml:id="para_fff81e46-ed75-4f76-942f-43bfe1292311">The following abbreviations are used in the Condition field:</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>XOR</term>
                        <listitem>
                            <para xml:id="para_c6852a6b-e857-463c-8a49-94996f1ff522">Exclusive OR. One and only one row shall be selected from mutually-exclusive options.</para>
                            <note>
                                <para xml:id="para_66332362-d2f7-49e6-882e-55298aa6bfb3">For example, if one of rows 1, 2, 3 or 4 may be included, then for row 2, the abbreviation "XOR Rows 1, 3, 4" is specified for the condition.</para>
                                <para xml:id="para_2d00d94b-472f-4b3e-a63a-932ebe7a1793"/>
                                <!-- for formatting :( -->
                            </note>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>IF</term>
                        <listitem>
                            <para xml:id="para_5b27de31-4745-4dd3-8e40-de273a74e04f">Shall be present if the condition is TRUE; may be present otherwise.</para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>IFF</term>
                        <listitem>
                            <para xml:id="para_c4f4dd35-7ec5-4761-8724-6097a4f38ae0">If and only if. Shall be present if the condition is TRUE; shall not be present otherwise.</para>
                        </listitem>
                    </varlistentry>
                </variablelist>
            </section>
            <section label="6.1.9" status="3" xml:id="sect_6.1.9">
                <title>Value Set Constraint</title>
                <para xml:id="para_7fb84d80-4f96-45d2-b23b-e307b6e5f2cf">Any constraints on the Value Set for a CODE Content Item are specified in this field as defined or enumerated coded entries, or as baseline or defined Context Groups.</para>
                <para xml:id="para_d1183585-59f1-4a49-bcc7-fb38e0d259f9">The absence of an entry in the Value Set Constraint field for a CODE Content Item means that any code may be used, from any Coding Scheme, including codes from private Coding Schemes.</para>
                <para xml:id="para_5513bb29-d458-42c6-bd5f-0b991a11bf5c">The Value Set Constraint field may specify a default value for the Content Item if the Content Item is not present, either as a fixed value, or by reference to another Content Item, or by reference to an Attribute from the Data Set other than within the Content Sequence (0040,A730). For example:</para>
                <itemizedlist>
                    <listitem>
                        <para xml:id="para_edb45799-84d1-4dd7-b773-fab4d8bc701f">Defaults to <link linkend="DCM_121006" xrefstyle="select: nopage">(121006, DCM, "Person")</link>
                        </para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_e16f9269-b522-4950-867f-bc315103d5be">Defaults to Value of Institution Name (0008,0080) of the <olink targetdoc="PS3.3" targetptr="sect_C.7.5.1" xrefstyle="select: title"/>
                        </para>
                    </listitem>
                </itemizedlist>
                <para xml:id="para_d2b58492-32af-48eb-96f0-e439ec107673">A default value may also be specified to indicate that a Content Item is expected to have a particular value unless there is a reason for it to be different. This is especially true in the case where a Content Item is mandatory and, therefore, must not be absent.</para>
                <note>
                    <para xml:id="para_a3ac33e0-e70f-49cf-acc3-a72cda935284">For the UIDREF Content Item in Row 1 of <xref linkend="sect_TID_1004" xrefstyle="select: labelnumber quotedtitle nopage"/>, the Value Set Constraint column specifies: "Defaults to Value of Device UID (0018,1002) of the <olink targetdoc="PS3.3" targetptr="sect_C.7.5.1" xrefstyle="select: title"/>". That means, the value of this Content Item should be the same as the value of the referenced Attribute unless there is a reason for it to be different.</para>
                </note>
                <section label="6.1.9.1" status="4" xml:id="sect_6.1.9.1">
                    <title>NUM Units Constraint</title>
                    <para xml:id="para_f09fb01b-b7f0-49ff-8954-b30dd7d1c940">Any constraints on units of measurement are specified in the Value Set Constraint field if and only if the Value Type is NUM. The constraints are specified either as defined or enumerated coded entries, or as baseline or defined Context Groups. For example:</para>
                    <itemizedlist>
                        <listitem>
                            <para xml:id="para_847b6c40-37b5-4a48-9926-b91c8571d633">UNITS = EV (mm, UCUM, "mm")</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_819d0d55-1871-447b-9964-1a1026617114">UNITS = D<xref linkend="sect_CID_7460" xrefstyle="select: labelnumber quotedtitle nopage"/>
                            </para>
                        </listitem>
                    </itemizedlist>
                    <para xml:id="para_1f72f5e4-e5db-4481-886e-3ec1ef45e384">The constraints on the units apply only when Measured Value Sequence (0040,A300) contains an Item (i.e., a numeric value is present).</para>
                    <note>
                        <para xml:id="para_6e23c1f1-c6b7-4c51-b467-8c56c9e9041b">The presence of constraints on the units does not imply that a value is required to be sent, since Measured Value Sequence (0040,A300) is Type 2 and may be zero length if permitted by the Requirement Type for the Content Item in the Template.</para>
                    </note>
                    <para xml:id="para_6ab76035-ef26-46d9-bfc0-a0febc092925">The absence of any constraint on units of measurement means that any code for units may be used, from any Coding Scheme, including codes from private Coding Schemes.</para>
                </section>
                <section label="6.1.9.2" status="4" xml:id="sect_6.1.9.2">
                    <title>CONTAINER Continuation Flag Constraint</title>
                    <para xml:id="para_c4a30e07-bf72-4765-a2a8-2e596d4572c3">The value of the Continuity of Content Flag (0040,A050) may be specified in the Value Set Constraint field if and only if the Value Type is CONTAINER.</para>
                    <note>
                        <para xml:id="para_16d0f08d-0ce5-424e-9c2f-1ff140c06cce">The <olink targetdoc="PS3.3" targetptr="sect_C.17.3" xrefstyle="select: title"/> specifies "SEPARATE" and "CONTINUOUS" as the Enumerated Values for Continuity of Content Flag (0040,A050).</para>
                    </note>
                </section>
                <section label="6.1.9.3" status="4" xml:id="sect_6.1.9.3">
                    <title>SCOORD Graphic Type Constraint</title>
                    <para xml:id="para_9761cffe-cf38-4d05-aabf-a56c4a35f2ec">Constraints on the value of the Graphic Type(0070,0023) may be specified in the Value Set Constraint field if and only if the Value Type is SCOORD. The constraint may specify a set of allowed values, or a set of disallowed values. For example:</para>
                    <itemizedlist>
                        <listitem>
                            <para xml:id="para_1565233d-8d54-44de-a6d4-37f4da332816">GRAPHIC TYPE = {POINT}</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_48969aa5-5122-413f-a59d-ce614974f1b3">GRAPHIC TYPE = {CIRCLE, ELLIPSE}</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_13ffdbc4-e4b6-4c0c-a568-794cc51ac0f7">GRAPHIC TYPE = not {MULTIPOINT}</para>
                        </listitem>
                    </itemizedlist>
                </section>
                <section label="6.1.9.4" status="4" xml:id="sect_6.1.9.4">
                    <title>TABLE Row, Column, Units and Coded Content Constraints</title>
                    <para xml:id="para_fa29cce8-b421-4343-8bac-77e5603a7f08">Constraints on various aspects of the TABLE Content Item may be specified in the Value Set Constraint field, including the manner of encoding the tabulated values, either by row, by column, by individual cells, or by reference to other Content Items, by specifying:</para>
                    <itemizedlist>
                        <listitem>
                            <para xml:id="para_a3e13667-4990-485d-b24c-79bbf3bb4399">Fixed values, minimums and/or maximums for the number of table rows (NROWS) and/or columns (NCOLUMNS) </para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_19ba3735-97b0-4f0c-9f83-f74474c45284">Defined or enumerated coded entries, or baseline or defined Context Groups for Concept Name Code Sequence (0040,A043) to use in Table Row Definition Sequence (0040,A806) (ROW n) and/or Table Column Definition Sequence (0040,A807) (COLUMN n)</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_c2d85ae4-85c3-4300-959d-328c44de171f">Defined or enumerated coded entries, or baseline or defined Context Groups for Concept Code Sequence (0040,A168) to use in Cell Values Sequence (0040,A808) (ROW n VALUES) and/or (COLUMN n VALUES) and/or (CELL r, c VALUES)</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_2a17340a-e6ad-488b-b2f1-9bcc6b1dd182">Defined or enumerated coded entries, or baseline or defined Context Groups for Measurement Units Code Sequence (0040,08EA) to use in Table Row Definition Sequence (0040,A806) (ROW n UNITS) and/or Table Column Definition Sequence (0040,A807) (COLUMN n UNITS) and/or Cell Values Sequence (0040,A808) (CELL r, c UNITS)</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_7fbe6dd1-c4c3-42d3-82ad-ee0d9a266e5e">Permitted VR to use in Selector Attribute VR (0072,0050) for specified rows (ROW n VR) , columns (COLUMN n VR) or cells (CELL r,c VR) , when values are encoded literally</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_0281bf9b-6d90-485d-a25c-9f917d861317">Permitted referenced Content Item target (TID ttt ROW rrr) for specified rows (ROW n REF) , columns (COLUMN n REF) or cells (CELL r,c REF), when values are specified by reference</para>
                        </listitem>
                    </itemizedlist>
                    <para xml:id="para_3b838e0c-0c73-4779-90f7-c7a00385d041">It is also helpful to provide a detailed description of the form of the table in the corresponding Content Item Description.</para>
                    <para xml:id="para_a3bcf48b-4d9c-48f5-9477-77632a0b879b">
                        <emphasis role="bold">Example 1:</emphasis>
                    </para>
                    <informaltable frame="box" rules="all">
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_aa3c7376-106a-4728-a67d-7289c48d982b"/>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4621d15d-96e6-4fe2-9489-0f1da974c349">NL</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_1022527a-6ccd-4a6e-a30e-9e15a403a345">Rel with Parent</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_75ce6cdb-c1b3-4d32-8f97-c86cd06ae7e6">VT</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_fe3210a6-6830-4b11-b717-2ff6f3d94c93">Concept Name</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ede56007-bf1b-429e-a505-55e155c4802e">VM</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f93d8319-ee3d-42c9-ad5d-78b5fad6550e">Req Type</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_795cf9b8-de4e-4d53-8472-e5cab267c4ea">Condition</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_dba0e6a8-4506-4cfb-8dc7-acce868c98df">Value Set Constraint</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ab58b874-9525-4bd3-8a69-c99ff5d3a4e6">5</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_07e3e224-3fc5-4547-8fd2-5978d6ab9916">CONTAINS</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_11f0f8fb-1d19-4a5a-bba7-ab5957e748fa">TABLE</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_06537843-8d2f-4385-b650-bb81cc1648a4">EV (113734, DCM, "X-Ray Tube Current")</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a580b913-2559-4b0f-baf0-fe646683b8ed">1</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_336727e7-70a6-4678-8434-000d30fafa0c">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_040626cc-c3b0-4b0c-b8da-c2d2c6ae9f97">NCOLUMNS = 2</para>
                                    <para xml:id="para_ea84452e-8b6f-4f47-8c82-73be3feccc6d">COLUMN 1 = EV (111526, DCM, "DateTime Started")</para>
                                    <para xml:id="para_d3f84c10-f220-47a3-9725-46b218911781">COLUMN 2 = EV (113734, DCM, "X-Ray Tube Current")</para>
                                    <para xml:id="para_0cface52-fadc-48f5-9d8d-51910c561d07">COLUMN 2 UNITS = EV (mA, UCUM, "mA")</para>
                                    <para xml:id="para_0416780e-287a-4aa9-9348-2828ebcc8cb4">COLUMN 1 VR = DT</para>
                                    <para xml:id="para_d279cc68-4698-40cd-9b19-ab95f0ce2f6b">COLUMN 2 VR = FL</para>
                                </td>
                            </tr>
                        </tbody>
                    </informaltable>
                    <para xml:id="para_420ec232-8f1f-4f88-b996-098d9d827914">
                        <emphasis role="bold">Content Item Descriptions</emphasis>
                    </para>
                    <informaltable frame="box" rules="all">
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_299d08c2-7f8b-46c9-a164-83eb58fd4186">Row 5</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a5445421-ad80-4d3c-b837-a836e3e6263b">The table of X-Ray Tube Current is encoded as a two-column table, consisting of multiple rows describing corresponding values of datetime and X-Ray tube current. The number of rows is not constrained.</para>
                                </td>
                            </tr>
                        </tbody>
                    </informaltable>
                    <para xml:id="para_95d864a9-57cf-4a7e-a1c2-8fa62dc887bd">
                        <emphasis role="bold">Example 2:</emphasis>
                    </para>
                    <informaltable frame="box" rules="all">
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_36192468-b1b9-4c5b-a564-a9ddede13891"/>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_588393f6-eff5-49e4-a9e4-8429fe16f16a">NL</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_956d75bc-917c-4ed7-9868-a5a3e92e0418">Rel with Parent</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b7340926-bf6f-4f04-b853-70a774c7f574">VT</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f15b1a42-5bbc-4ac9-905c-45fdf94416fc">Concept Name</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f5816c87-432b-4eb8-be52-58ae5e9a5653">VM</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a1e49e65-f5c2-4919-984b-09f69905089c">Req Type</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a9d5ca0a-a5af-48a5-a0e3-933c81e7bd28">Condition</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_291d0ff0-e717-48a1-ad34-9fadf3fa2f4f">Value Set Constraint</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7414e59d-dc8e-4784-84f7-77a19c73d80b">5</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f41622b1-a170-4b79-ac5a-af15b8205cf0">CONTAINS</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ee9db52e-32c6-4e73-85f1-b4c3acb641ae">TABLE</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_792f5c81-7231-41b7-9e06-9bec0ea48108">EV <link linkend="DCM_130520" xrefstyle="select: nopage">(130520, DCM, "Transformation Matrix")</link>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9ad15479-269b-40aa-8615-09598076d118">1</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_183decce-690f-4dff-bdc5-ba2aaa74aa2c">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4e6c6135-ee2d-4c3e-aecf-25dc4b4d3c69">NCOLUMNS = 4</para>
                                    <para xml:id="para_c6638d69-74a7-4779-a417-05e346d7b684">NROWS= 4</para>
                                    <para xml:id="para_3b706e0f-b35c-434b-b1ae-64466c49a72c">CELL VR = FD</para>
                                </td>
                            </tr>
                        </tbody>
                    </informaltable>
                    <para xml:id="para_2a2d88bd-b508-43a6-8500-abe792787940">
                        <emphasis role="bold">Content Item Descriptions</emphasis>
                    </para>
                    <informaltable frame="box" rules="all">
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_373187d1-8c0b-492a-bde7-93f03a83dabc">Row 5</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a94f71e9-5e36-4b99-a0ab-c8c29fc0f6d3">The Transformation Matrix is encoded as a 4 by 4 matrix of dimensionless numbers of the form defined in <olink targetdoc="PS3.3" targetptr="sect_C.20.2.1.1" xrefstyle="select: docname label title"/>. The table may be encoded as entire rows, entire columns or individual cells of double float numeric values.</para>
                                </td>
                            </tr>
                        </tbody>
                    </informaltable>
                    <para xml:id="para_b74f501f-caf8-4d64-a272-d8a04e288d7c">
                        <emphasis role="bold">Example 3:</emphasis>
                    </para>
                    <informaltable frame="box" rules="all">
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_15ec355a-2ead-41ef-8930-0426d039913a"/>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ef09bd66-105e-4509-b710-a30b20512474">NL</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_0b0eb400-ae2f-4a0a-83d5-d1c273b2fb7b">Rel with Parent</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b58cc5bd-c75b-4d83-b555-42da910283f2">VT</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_1c45b69a-28c6-4422-af35-385777dc174a">Concept Name</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ef4d886b-ea1d-4881-9c67-daaa16086cee">VM</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_0483b1b7-3d7d-4239-a501-d4fc5e255496">Req Type</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_0e90c960-dc63-4bb7-a51f-40c451c3401a">Condition</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9336caef-033b-4af9-96e0-37e1ec0fa50d">Value Set Constraint</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0afc1737-78cb-418d-9c61-8dcc29129919">5</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9208c69a-42b2-4008-96b9-972dfb2df130">CONTAINS</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e7ea73b0-a84d-49a6-81af-27604018cd64">TABLE</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_bfe4cd7f-2817-456e-b13a-1f687e07dfc1">EV (126081, DCM, "RECIST 1.1")</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fc0a134d-aad8-4e80-9a47-405851316a12">1</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5f853b45-132c-4724-a35a-7458c3380759">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6fa84784-5fe2-4e35-b195-af87de75ba73">NCOLUMNS = 4</para>
                                    <para xml:id="para_2ba31c83-a6f0-4f1c-87ab-5812d92a852b">COLUMN 1 = EV (112039, DCM, "Tracking Identifier")</para>
                                    <para xml:id="para_c3057d59-bbe7-460b-b0d1-3f47d028dd0c">COLUMN 2 = EV (363698007, SCT, "Finding Site")</para>
                                    <para xml:id="para_bb4f1bf8-7f1a-4745-aafc-3fd53d84411e">COLUMN 3 = EV (272741003, SCT, "Laterality")</para>
                                    <para xml:id="para_7f299076-5a2f-4d60-8b0f-609b5729178a">COLUMN 4 = EV (103339001, SCT, "Long Axis")</para>
                                    <para xml:id="para_aac62d91-aade-48d4-854d-a108dba0eda4">COLUMN 4 UNITS = EV (mm, UCUM, "mm")</para>
                                    <para xml:id="para_e876ece6-e975-4b27-b083-ce885ceecd74">COLUMN 1 REF = TID 1500 ROW 9 &gt; TID 1501 ROW 2</para>
                                    <para xml:id="para_0a74bdea-bae7-44fe-b16a-006563855931">COLUMN 2 REF = TID 1500 ROW 9 &gt; TID 1501 ROW 6</para>
                                    <para xml:id="para_ab760f3a-dba2-4785-b5c5-6510f772dade">COLUMN 3 REF = TID 1500 ROW 9 &gt; TID 1501 ROW 7</para>
                                    <para xml:id="para_ce2264da-af29-4ffd-b690-3fdd4cc8be2b">COLUMN 4 REF = TID 1500 ROW 9 &gt; TID 1501 ROW 10 &gt; TID 300 ROW 1</para>
                                </td>
                            </tr>
                        </tbody>
                    </informaltable>
                    <para xml:id="para_501b9932-7e8a-4f92-aa17-5bb36185d0e3">
                        <emphasis role="bold">Content Item Descriptions</emphasis>
                    </para>
                    <informaltable frame="box" rules="all">
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_bff0fe10-a6cc-48c8-bfc5-f33dfb6592be">Row 5</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9f3ccfdb-a59f-4b9d-9d81-de3a076ab8c1">The table of RECIST long axis measurements per target lesion is encoded as a four-column table, consisting of multiple rows describing corresponding values of Tracking Identifier, Finding Site, Laterality and Long Axis in mm by reference to other Content Items. The number of rows is not constrained. The Response Criteria is used as the Concept Name of the table.</para>
                                </td>
                            </tr>
                        </tbody>
                    </informaltable>
                    <para xml:id="para_e38fc122-1899-4b38-928f-7f0f4051e3fb">
                        <emphasis role="bold">Example 4:</emphasis>
                    </para>
                    <informaltable frame="box" rules="all">
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f24c537a-060c-499e-910a-401dd7e9cdff"/>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2e196fcd-08db-48fd-9614-3b7c402b8fe7">NL</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_04ae3ecf-c7a2-488e-9179-8f76fa71ca6a">Rel with Parent</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_508e61e3-2527-4c54-9d0d-b49b641b69ff">VT</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a9cf9371-a0fc-4e6e-8d4f-3beda93c455a">Concept Name</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_679431aa-6a19-455a-ae32-e857bb1dbd58">VM</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c8804d14-6a91-4452-966c-d39f58904835">Req Type</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a6f531fd-3d7b-4838-ae91-eff01b4fdf1a">Condition</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_aa27d636-84e8-4b25-baa7-6a5c156fcf34">Value Set Constraint</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_05cbabc8-0aac-4f51-a1fe-e47c303815f0">6</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_64b358c7-d59e-4730-a607-4fcebd76b009">&gt;</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e3bbe2fd-6eba-4c98-a328-27857416d20c">CONTAINS</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_51246268-f278-4f4e-8cb0-6abe3615733b">TABLE</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_abcfd1c9-a575-4e2b-8c8b-0da77a280b61">EV (111632, DCM, "Anode Target Material")</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ac5dde9e-a70d-4ba8-9df9-5d316694e867">1</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6eea3dd9-8afd-4fc8-85a1-dd875da1705e">UC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_522872de-e7b0-4e0d-bb15-e22a866c3b26">XOR Row 6a</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8335d583-47c5-46dd-8ca4-a8783e043526">&gt;NCOLUMNS = 2</para>
                                    <para xml:id="para_daa4c0b5-c7d4-4b88-a1df-8880f33fa4a9">COLUMN 1 = EV (111526, DCM, "DateTime Started")</para>
                                    <para xml:id="para_2cc49fa6-0fb3-4fd5-8f00-697a363f088e">COLUMN 2 = EV (111632, DCM, "Anode Target Material")</para>
                                    <para xml:id="para_01589e26-4d79-45a1-83a6-4475f5321b30">COLUMN 2 VALUES = DCID 10016 "Anode Target Material"</para>
                                    <para xml:id="para_4f050a03-4aad-4a7c-9fab-e38eec61f1f1">COLUMN 1 VR = DT</para>
                                    <para xml:id="para_0ae61297-6db9-4d5d-a6a2-4e6e710c8b43">COLUMN 2 VR = SQ</para>
                                </td>
                            </tr>
                        </tbody>
                    </informaltable>
                    <para xml:id="para_94fa50e9-58b0-46f5-a0ab-3dd75146b85d">
                        <emphasis role="bold">Content Item Descriptions</emphasis>
                    </para>
                    <informaltable frame="box" rules="all">
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9deb3209-32a7-4644-aac2-d31f66ad3240">Row 6</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6cb34f49-aeeb-463e-80a1-717f50cdbfa2">The table of Anode Target Material values is encoded as a two-column table, consisting of multiple rows describing corresponding values of DateTime Started and Anode Target Material Code Values. The number of rows is not constrained. The Anode Target Material is encoded using a code selected from a Defined Context Group.</para>
                                </td>
                            </tr>
                        </tbody>
                    </informaltable>
                </section>
            </section>
        </section>
        <section label="6.2" status="2" xml:id="sect_6.2">
            <title>Special Conventions for Template Tables</title>
            <section label="6.2.1" status="3" xml:id="sect_6.2.1">
                <title>Multiple Value Sets Depending on Different Conditions</title>
                <para xml:id="para_2f8fb880-45d8-426c-8fb9-adb9fe19a110">When a Content Item may have different Value Sets, each depending on different conditions, the description of each different case begins in a separate row of the Template table.</para>
            </section>
            <section label="6.2.2" status="3" xml:id="sect_6.2.2">
                <title>Target Content Items of Relationships</title>
                <para xml:id="para_ae2f84bc-dffe-46a8-906d-2217af7d469e">When it is necessary to specify the Target Content Item(s) of a relationship, they are specified in the row(s) immediately following the Source Content Item. The Nesting Level of a Target Content Item (or set of Target Content Items specified indirectly via inclusion of another Template, see <xref linkend="sect_6.2.3" xrefstyle="select: label"/>) is one greater than the Nesting Level of the corresponding Source Content Item, as indicated by an increase in the number of "&gt;" characters in the Nesting Level.</para>
                <para xml:id="para_6b8edd6a-7024-4d84-af61-984d266b47de">When a Content Item may be the Source Content Item of multiple relationships having different Relationship Types and/or different Relationship Modes and/or different patterns of Target Content Item(s), the description of each different case begins in a separate row of the Template table.</para>
                <para xml:id="para_39c07005-f65d-4cfd-9258-c7cb5cdb3536">When the Source Content Item of a relationship has a VM of greater than 1, the specified pattern of Target Content Items applies to all instantiations of the Source Content Item.</para>
                <note>
                    <para xml:id="para_a4dc83e0-9e71-49f3-af19-58a15c6f5be8">For example, if a Template specifies that the VM of a Source Content Item is 1-n and specifies a by-value relationship to two CODE Content Items with particular Value Set constraints, then each instantiation of the Source Content Item has a by-value relationship to two CODE Content Items with the specified value constraints.</para>
                </note>
                <para xml:id="para_540d97aa-5e6d-465a-a263-02e5c9bab05a">When a Source Content Item that has a Requirement Type of U, UC or MC is not present (is not instantiated), no Target Content Items of that Source Content Item are present, even if one or more of the Target Content Items is designated with a Requirement Type of M or MC.</para>
                <note>
                    <para xml:id="para_2e1daf33-e3f7-4128-a5ca-ab0c07815096">In other words, potential children are not present when there is no parent.</para>
                </note>
            </section>
            <section label="6.2.3" status="3" xml:id="sect_6.2.3">
                <title>Inclusion of Templates</title>
                <para xml:id="para_63f39f14-f661-49ba-947d-60a32e5e317d">A Template may specify another Template to be included by specifying "INCLUDE" in the Value Type field and the identifier of the included Template in the Concept Name field.
                    All of the rows of the specified Template are in included in the invoking Template, effectively substituting the specified Template for the row where the inclusion is invoked.
                    Whether or not the inclusion is user optional, mandatory or conditional is specified in the Requirement and Condition fields.
                    The number of times the included Template may be repeated is specified in the VM field.</para>
                <note>
                    <para xml:id="para_5629d439-87db-4748-b2b7-fa35ffbbf272">As defined in <xref linkend="sect_6.1.3" xrefstyle="select: label"/>, there can be no conflict between the Relationship Type and Mode of a row that includes another Template and the Relationship Type and Mode of the rows of the included Template.</para>
                </note>
                <section label="6.2.3.1" status="4" xml:id="sect_6.2.3.1">
                    <title>Template Parameters</title>
                    <para xml:id="para_9f50e959-fd54-4495-b2a4-c73310856b9c">A Template that is included by another Template may include parameters that are replaced by values defined in the invoking Template. Parameters may be used to specify coded concepts or Context Group Identifers in the Concept Name, Condition, or Value Set Constraint fields of a Template.</para>
                    <para xml:id="para_66b13b34-48c6-44ef-aedd-6cde668b55b7">An included Template that accepts parameters shall be introduced by a table listing those parameters of the form:</para>
                    <informaltable frame="box" rules="all">
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4ec701bc-fbfc-4d19-8932-6a142c416334">Parameter Name</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b51bb909-c302-407d-9465-7ff943c83124">Parameter Usage</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_49287f53-ddef-4a94-a89a-71c6660c07fb">...</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_7686df47-3766-43d7-9f6f-6c86c761c01a">...</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_544be0dc-eaa5-4df8-b130-0466830fab24">...</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b943d909-6b97-4165-acff-9985130ae99c">...</para>
                                </td>
                            </tr>
                        </tbody>
                    </informaltable>
                    <para xml:id="para_84a294db-dc00-4a92-a924-1330cd02300e">Parameters are indicated by a name beginning with the character "$".</para>
                    <para xml:id="para_7f9213b8-bce2-4c39-83c5-9edbfa4983ea">The invoking Template may specify the value of the parameters in the included Template by name in the Value Set Constraint field of the INCLUDE row. The parameter in the included Template shall be replaced by the specified parameter value. Specification of a parameter value shall be of one of the following forms:</para>
                    <informaltable frame="box" rules="all">
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_60d14098-56b9-4699-98b4-f782dff4a8fa">Notation</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_89c08a5c-7e26-4748-bb09-a4221ff06649">Definition</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b3ca4230-36e9-49b3-9922-e51e6862f8b1">$parametername = EV or DT (CV, CSD, "CM")</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d880c609-919e-4bbd-a595-b03c73f19851">The parameter passed to the Template is the specified coded term.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b37680a5-e6e6-4331-8760-a337b03289d8">$parametername = (CV, CSD, "CM")</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a3d4765e-9894-44ed-88ce-a393945cf0c5">The parameter passed to the Template is the specified coded term, used as a parameter in a Condition field of the included Template.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ab898f9a-0e1e-4343-a449-d124a4c46b65">$parametername = BCID or DCID (CID) CNAME</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_08a81dc9-4fa1-4651-acdd-7cea904124a7">The parameter passed to the Template is the Context Group.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_31373402-ce8c-4f60-9707-e3fb26827383">$parametername = MemberOf {BCID or DCID (CID) CNAME}</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_59c2683e-ca63-471c-a83e-ba2421874522">The parameter passed to the Template is a single coded term from the Context Group in curly braces.</para>
                                </td>
                            </tr>
                        </tbody>
                    </informaltable>
                    <para xml:id="para_52383bcd-c966-49b6-b20d-fa274cc4fb3b">The specification of a parameter value is valid only for the directly included Template. Therefore, it needs to be explicitly respecified in Templates intermediate between the originally specifying Template and the target Template. The intermediate Template may use the same parameter name as used by the Template it invokes; in such a case, the intermediate Template would invoke the subsidiary Template with a specification in the Value Set Constraint field such as:</para>
                    <para xml:id="para_9b403ddb-09e7-4848-9fb0-66bf321c70dd">$parametername = $parametername</para>
                    <note>
                        <para xml:id="para_bf947da5-798f-4a05-8fb4-dae987f4c270">In this case, the left hand instance of $parametername is the name in the subsidiary Template, and the right hand instance is the (parametrized) value passed into the current Template.</para>
                    </note>
                    <para xml:id="para_2d76bb64-dc59-42f6-99b7-c8782cbb4a22">The invoking Template is not required to specify all parameters of included Templates. If not specified, the Value Set (term or Context Group) for that parameter is unconstrained. An unconstrained value in a Condition will cause the condition to fail.</para>
                </section>
            </section>
            <section label="6.2.4" status="3" xml:id="sect_6.2.4">
                <title>Post-coordinated Codes and Has Concept Modifier Relationship</title>
                <para xml:id="para_e6a61439-0de4-4914-a6c7-7f3013a0e770">Though it may not be explicitly shown in a particular Template, the use of any coded Concept Name in any Content Item may be defined in a post-coordinated rather than pre-coordinated manner, unless explicitly forbidden by the IOD or the Template.</para>
                <para xml:id="para_d316860c-cecb-4a06-a7ce-eee912cd4b99">Accordingly, any such Content Item may have any number of Target Content Items via a "HAS CONCEPT MOD" relationship, even if not explicitly specified in a Template. Each Target Content Item of such a relationship may be more complicated than a single Content Item if the IOD permits (i.e., the post-coordinated concept may potentially be defined by a complex sub-tree).</para>
            </section>
            <section label="6.2.5" status="3" xml:id="sect_6.2.5">
                <title>Extension of Templates</title>
                <para xml:id="para_81f5b6f8-498d-491d-9608-c7a76567c4c1">An Extensible Template may be extended in an application generating SOP Instances to include additional Content Items in its definition. Such Content Items shall not duplicate concepts for which an encoding is defined in the Template. I.e., if a method is provided for the encoding of a concept in the Template, that concept shall not be encoded using a different Content Item in an extension to the Template.</para>
                <note>
                    <para xml:id="para_b11030d7-9927-459c-9391-4366fd637fab">There is no requirement that the included additional Content Items in a Template extension be placed at the end of the Template. The additional Content Items may be included at any semantically appropriate location in the Template, regardless of whether the order of Content Items in the Template is significant.</para>
                </note>
                <para xml:id="para_258bd175-80b2-4f6c-a5a4-fc31be789c2b">A Non-extensible Template shall not be modified in an application by the addition of Content Items to its definition.</para>
                <note>
                    <para xml:id="para_276e3ec3-0839-4589-b579-6ed04b4576d9">The set of Content Items in either an Extensible or a Non-extensible Template may be changed in subsequent editions of the Standard, in accordance with the procedures of the DICOM Standards Committee.</para>
                </note>
                <para xml:id="para_d1310cff-3408-4561-92c3-0af0f13dadaf">A Non-Extensible Template may include a Template that is Extensible. In invoking such a Template, the content structure of SOP Instances created from the Non-Extensible Template may vary according to the varying content structure allowed by the extension of the included Template.</para>
                <note>
                    <para xml:id="para_90e68468-f930-4318-a531-eac0acbcec6e">Specification of such extensible content in a Non-Extensible Template may be desirable if the Template defines, e.g., a fixed top level structure into which a variety of lower level structures may be "plugged".</para>
                </note>
            </section>
        </section>
    </chapter>
    <chapter label="7" status="1" xml:id="chapter_7">
        <title>DCMR Context Group Specifications</title>
        <para xml:id="para_7b60da48-0a38-409e-9f31-e267e5d6e264">Context Groups specify Value Set restrictions for Code Value (0008,0100) (or Long Code Value (0008,0119) or URN Code Value (0008,0120)) and Code Meaning (0008,0104) of Code Sequence Attributes for given functional or operational contexts. This Section specifies the semantics of DCMR Context Group Tables.</para>
        <section label="7.1" status="2" xml:id="sect_7.1">
            <title>Context Group Table Field Definition</title>
            <para xml:id="para_d43ef242-8508-4d8e-8547-0b125f8fb81e">Context Groups are described using tables of the following form (optional columns are shown with italic column titles):</para>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_40545be3-db75-4654-9aa2-d33cfc2a7cd8">
                            <emphasis role="bold">HTML | FHIR JSON | FHIR XML | IHE SVS XML</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Keyword:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_9bfd78e2-b936-4d0c-ac8d-4bb9a3e35836">
                            <emphasis role="bold">&lt;Context Group Keyword&gt;</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">FHIR Keyword:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_77f6b4f0-ff3e-45e0-a664-ced42b654d03">
                            <emphasis role="bold">dicom-cid-&lt;#&gt;-&lt;Context Group Keyword&gt;</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_2f8ab50c-2a0b-4f5f-8746-256b7f161884">
                            <emphasis role="bold">(Non-) Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_4b33049a-76b3-4c3b-851c-664cb4220e9b">
                            <emphasis role="bold">&lt;yyyymmdd&gt;</emphasis> or <emphasis role="bold">Not versioned</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_779c8099-f7f1-4a63-a819-61b017fb8101">
                            <emphasis role="bold">1.2.840.10008.6.1.uuuu</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID &lt;#&gt;" rules="all">
                <caption>&lt;Context Group Name&gt;</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f89a2f85-04d3-46cb-bdbe-16c2e2c9c1bb">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dcc83e03-3a66-45ce-8cb3-ae5d69a68c58">
                                <emphasis role="italic">Coding Scheme Version</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ade1c4b9-18be-49d4-b1b7-eaa438f70808">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6a2d25ef-ab97-4cfd-b5cc-ac9cec9af74e">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1a429f4a-f643-4323-ae5b-ff8a2d5530aa">
                                <emphasis role="italic">&lt;Reference Terminology&gt; Equivalent Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_024f7fe6-734f-4a6f-9838-9e3b26a64143">Units</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_84b6a008-db63-4938-bb48-d9adcf3b8388">...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b57a17e2-1a50-4f9c-ad88-174c821e6729">...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_34c3b9e7-6ff0-4415-a1b7-651825150a22">...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_058a3805-9072-46ba-99f2-02a8baef20ea">...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ffbe8946-ef4a-4e8f-a6de-5f3d525f6125">...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bae6210b-24b1-4839-81cc-f8bb5d3b718e">...</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0f1affb1-3bca-4ccf-af1f-557c0b531f35">...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_64c24369-afa5-4858-8bad-09b1d55da173">...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dac89174-1d63-47c7-b3d6-cf35acac00b4">...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0c1036b3-bf1c-43f0-b26e-b5c5bae195ed">...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0955cfe0-840e-4f34-8c17-402237b045a9">...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f00b286c-2f29-448c-acf1-ad615a62d3ee">...</para>
                        </td>
                    </tr>
                </tbody>
            </table>
            <para xml:id="para_79b1ac80-fa8d-4633-a41f-b4c36708a76f">A row of a Context Group table specifies one coded concept. Each Context Group table is:</para>
            <itemizedlist>
                <listitem>
                    <para xml:id="para_6ef26f2c-0beb-426e-af8c-2898e18c65b3">named by a title</para>
                </listitem>
                <listitem>
                    <para xml:id="para_789ec019-4907-433c-b206-50728858dae9">identified by a CID number</para>
                </listitem>
                <listitem>
                    <para xml:id="para_29d51be0-4722-4cd9-ac96-9bf2e864a2da">identified by a version</para>
                </listitem>
                <listitem>
                    <para xml:id="para_fd20513d-54ad-4a36-9788-ac43adcd83ee">identified by a Keyword</para>
                </listitem>
                <listitem>
                    <para xml:id="para_c06f3be7-683e-4bed-b265-ed34bce9733b">identified by a FHIR Keyword</para>
                </listitem>
                <listitem>
                    <para xml:id="para_54bb8ace-005f-4828-b84c-9342200bb650">assigned a UID (that is defined in <olink targetdoc="PS3.6" targetptr="PS3.6" xrefstyle="select: labelnumber"/>)</para>
                </listitem>
                <listitem>
                    <para xml:id="para_c5eb43ff-0ec3-4fe4-aac8-0f183d190be5">linked to various resource files that contain representations of the Context Group (in FHIR JSON, FHIR XML and IHE SVS XML)</para>
                </listitem>
            </itemizedlist>
            <para xml:id="para_ba7cff55-b0d0-4aa9-98f6-abfade735fad">The columns of the tables consist of:</para>
            <itemizedlist>
                <listitem>
                    <para xml:id="para_57bf88d4-22d5-4a8e-9e7f-d7e0f9914e83">Coding Scheme Designator: the value of Coding Scheme Designator (0008,0102)</para>
                </listitem>
                <listitem>
                    <para xml:id="para_cfe96806-cd2f-4e80-b9e9-12451117df47">Code Value: the value of Code Value (0008,0100) or Long Code Value (0008,0119) or URN Code Value (0008,0120)</para>
                </listitem>
                <listitem>
                    <para xml:id="para_e9a4b74b-2e00-4c73-bde0-35d25b932325">Coding Meaning: the value of Code Meaning (0008,0104)</para>
                </listitem>
            </itemizedlist>
            <para xml:id="para_92bf91f5-20a0-422e-82a5-f569ef75056e">In those cases where it is necessary, Coding Scheme Version (the value of Coding Scheme Version (0008,0103)) may also be specified. This column may be absent if Coding Scheme Version is not required for any of the coded concepts in the Context Group.</para>
            <para xml:id="para_4dce29d6-e0e9-4158-8349-598b3d6c836d">The value specified in the Code Meaning field is an acceptable value for the specified Code Value, but does not preclude the use of other synonymous text in the same or other language.</para>
            <note>
                <orderedlist>
                    <listitem>
                        <para xml:id="para_84791042-b65c-43c2-a32d-2470915e84ff">Some Coding Schemes do not specify the equivalent of a Code Meaning.</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_92db93ea-430f-42a9-9f81-971b9ce08929">Capitalization in the Code Meaning is generally not significant, except for abbreviations used in units of measurement prefixes (e.g., "ml" milliliter vs. "Ml" megaliter, or "pV" picovolt vs. "PV" petavolt).</para>
                    </listitem>
                </orderedlist>
            </note>
            <para xml:id="para_4d900fd4-659d-404f-a601-b87ed27bb39c">If further description of the concept represented by the code is required in the DCMR (rather than referring to an external Coding Scheme), it is included in a separate table.</para>
            <para xml:id="para_32b8ebee-184f-4386-a49d-ad2aa2b8c1e9">Optional columns may provide an informative mapping from the coded concepts of the Context Group to a reference terminology specified in the column heading. Typical reference terminologies include SNOMED CT and UMLS.</para>
            <para xml:id="para_be54812e-092a-4644-bc36-f3a1bc3c5707">An optional column may provide a normative baseline or defined set of units to use for numeric measurements using the concept, either as a single term (e.g., DT ({ratio}, UCUM, "ratio")), a list of such terms, or a reference to a Context Group (e.g., DCID 7277 "Units of Diffusion Rate Area Over Time").</para>
            <para xml:id="para_0289f923-a7b4-47f9-aa04-c1327eebb16d">A Context Group may alternatively be defined by narrative reference to an externally defined Coding Scheme.</para>
            <note>
                <para xml:id="para_51d90a2d-1d17-4aad-b80a-367998cd89e2">See for instance <xref linkend="sect_CID_82" xrefstyle="select: labelnumber quotedtitle nopage"/>.</para>
            </note>
        </section>
        <section label="7.2" status="2" xml:id="sect_7.2">
            <title>Special Conventions for Context Group Tables</title>
            <section label="7.2.1" status="3" xml:id="sect_7.2.1">
                <title>Include Context Group</title>
                <para xml:id="para_cf95ca57-a2cb-40ab-8e0f-cf073f74cc34">The 'Include Context Group' macro is a concise mechanism for including (by-reference) all of the rows of a specified Context Group in the invoking Context Group, effectively substituting the specified Context Group for the row where the macro is invoked. If an 'Include Context Group' is specified, it shall be specified in the Concept Name column of a Context Group Table. Table 7.2.1-1 specifies the syntax of the 'Include Context Group macro. Inclusion may be nested, in that included Context Groups may themselves include other Context Groups. This gives rise to the possibility of circular inclusion and multiple inclusion, in which case the Context Group shall consist of the transitive closure of the set of all coded concepts within the included Context Groups.</para>
                <note>
                    <para xml:id="para_6699c5fc-4656-4b83-97b7-4d6966261442">For example, it is reasonable to have the following definitions for Context Groups:</para>
                    <itemizedlist>
                        <listitem>
                            <para xml:id="para_0580d732-e65a-4762-967b-b436fab46f3a">Context ID 1, includes Context IDs 2 and 3</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_e45facec-72de-4c9d-b93a-aa9df1e249ea">Context ID 2, includes Context IDs 4 and 5</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_5c60aa13-6e32-4ef9-bd5a-add0ebd0056a">Context ID 3, includes Context IDs 5 and 6</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_62b15e7f-8701-4541-b124-325a4278ecf3">Context ID 4 contains a, b, c</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_aaf06a8d-193e-4187-925a-432f1dda5546">Context ID 5 contains e, f, g</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_714dfb87-8b5e-4432-8df5-b1fd85ae5463">Context ID 6 contains a, h, i</para>
                        </listitem>
                    </itemizedlist>
                    <para xml:id="para_4adf1bfc-80db-440d-9d20-28b36339fa0a">The contents of Context ID 1 will be a, b, c, e, f, g, h, i.</para>
                </note>
                <table frame="box" label="7.2.1-1" rules="all" xml:id="table_7.2.1-1">
                    <caption>Include Context Group Macro</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c815472b-1fad-40e8-95a3-e63496f81841">Coding Scheme Designator</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_83b35564-2f46-4fbc-adcf-7598e5d79a82">Code Value</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d467c67f-6b3a-493c-82c6-4d5ddfd41bee">Code Meaning</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8bd8183e-15e2-4f4a-a89d-bc00509a0c86">…</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cdd934cd-972f-4395-b54d-f6418891db02">…</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1eeb525c-1da7-49e4-a275-449efab110eb">…</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="3" rowspan="1">
                                <para xml:id="para_a18d52db-d96e-4052-8c95-1a331ab8b1cf">
                                    <emphasis role="italic">Include CID nnn</emphasis>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d4991b09-fb3f-4ebe-8c2c-354479d4845c">…</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_34f13335-f7c3-4a7c-b98a-1d6d81c0ba0a">…</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83e566a7-e4a4-49fa-aa53-1a6020aec64f">…</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="7.2.2" status="3" xml:id="sect_7.2.2">
                <title>Measurement Unit</title>
                <para xml:id="para_a92ec74c-b0fb-4537-9e0d-0213bce91064">Context Group 82 is defined to include all units of measurement relevant to DICOM IODs. In the past it was envisaged that an extensible list of pre-coordinated codes would be included in the mapping resource.</para>
                <para xml:id="para_5579d69c-14ab-4f6a-a4cb-5836a9bd992d">DICOM has now adopted the Unified Codes for Units of Measurement (UCUM) standard for all units of measurement. This Coding Scheme allows for the "construction" of pre-coordinated codes from atomic components.</para>
                <para xml:id="para_319481f7-5126-45e6-974e-d307a8937bcb">The specialization of the UCUM standard as it is used in DICOM involves the following rules:</para>
                <itemizedlist>
                    <listitem>
                        <para xml:id="para_ce59b92f-30e4-482d-81e8-470067f36249">the Coding Scheme Designator is specified as "UCUM"</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_3eb47571-ddfa-45d5-b086-2cedc69bd1c1">the version of UCUM from which a code is constructed is not required, as it is not needed to resolve ambiguity in the Code Value or Code Meaning; however, there is no restriction on the version being specified in Coding Scheme Version</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_26febbb4-fa3d-4849-9b84-cc991e3d631a">the Code Value will be constructed from UCUM and make use of the "case-sensitive" form of UCUM code (e.g., "ml/s")</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_8aeb5075-aba3-4759-83d5-1c43406e147f">the Code Meaning for other than UCUM unity may be one of the following:</para>
                        <itemizedlist>
                            <listitem>
                                <para xml:id="para_534f93cc-aca7-4755-8a13-b0df31407aa9">the "print" value specified in UCUM (e.g., "mmHg" for Code Value mm[Hg])</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_86ec86a3-fbdb-4a73-81f8-402f7f12b846">the same string as sent in the Code Value (e.g., "ml/s")</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_dc53bd58-7fbf-47cd-b6b1-38c02f6b447c">constructed from the "names" of individual components using the Americanized form of name (e.g., "milliliters/second")</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_611952cc-ef9d-4c0c-8405-e1e7b9a637ca">constructed from the "names" of individual components using the European form of name (e.g., "<foreignphrase xml:lang="en-GB">millilitres</foreignphrase>/second")</para>
                            </listitem>
                        </itemizedlist>
                    </listitem>
                    <listitem>
                        <para xml:id="para_5db73b35-62b5-46b4-9436-acb29489cab4">In the case of UCUM unity ("1", or curly braces expression) it is forbidden to use "1" as a Code Meaning. <xref linkend="chapter_G" xrefstyle="template:Annex %n"/> provides Code Meanings for a Code Value (0008,0100) of 1. A Template or Context Group may constrain the Code Meaning according to the following rules:</para>
                        <itemizedlist>
                            <listitem>
                                <para xml:id="para_6dfe7eff-908a-4aef-ac63-1500f97e001e">UCUM default unit 1 shall use one of the Code Meaning synonyms specified in <xref linkend="chapter_G" xrefstyle="template:Annex %n"/>
                                </para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_20e5493f-af13-42e3-ba3c-c21980801165">ratios of identically dimensioned values may use ({ratio}, UCUM, "ratio")</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_945ea154-8a14-4e68-a7f4-3df63a9f0e3d">unitless numeric scores may use ({M:N}, UCUM, "range: M:N") to specify the minimum and maximum value, for example, ({0:10}, UCUM, "range: 0:10")</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_bd032db3-228d-48d0-8570-f8b933073429">counts using UCUM annotation shall always use the text within the curly braces as the Code Meaning, for example, ({masses}, UCUM, "masses")</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_a5bf59e2-0125-4fb2-aa34-c3ce7113a3b9">compositions of a curly braces expression with other UCUM values may use a conventional clinical representation, for example, ({H.B.}/min, UCUM, "BPM")</para>
                            </listitem>
                        </itemizedlist>
                    </listitem>
                </itemizedlist>
                <para xml:id="para_e16c21d5-586d-489f-9c74-f9fdfb25097e">The UCUM standard states that the preferred display values for codes deg (degrees of plane angle) and Cel (degrees Celsius) are "°" and "°C". However, the character ° does not have a representation in the DICOM default character set (ASCII, ISO-IR 6). The Code Meaning specified in this Part therefore uses "deg" and "C". SOP Instances that specify a Specific Character Set that allows the character ° may use Code Meanings "°" and "°C".</para>
                <note>
                    <orderedlist>
                        <listitem>
                            <para xml:id="para_ffab4057-eac8-4493-9194-69f924f63059">Code Meaning "C" formally conflicts with the Code Meaning for Coulomb. In the context of DICOM use, the possibility of confusion to a user based on the display of the Code Meaning is considered remote, as there is little use of Coulomb in imaging, and the context of the displayed item Concept Name would resolve between temperature and electric charge. Automated processing based on the Code Values should not face an issue as the Code Values differ.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_a9ffa14c-6e07-45b8-aca5-6745f97e0274">The character ° has Unicode code point U+00B0, and is represented as 0xB0 in ISO-IR 100 (Latin-1), ISO-IR 101 (Latin-2), ISO-IR 109 (Latin-3), ISO-IR 110 (Latin-4), ISO-IR 126 (Greek), ISO-IR 138 (Hebrew), and ISO-IR 148 (Latin-5). It is not encodable in ISO-IR 13 (Katakana), ISO-IR 144 (Cyrillic), ISO-IR 127 (Arabic), or ISO-IR 166 (Thai).</para>
                        </listitem>
                    </orderedlist>
                </note>
            </section>
            <section label="7.2.3" status="3" xml:id="sect_7.2.3">
                <title>Extension of Context Groups</title>
                <para xml:id="para_be6f9fe7-8445-4f73-b30a-5ca5f897714b">An application may extend an Extensible Context Group by adding terms for new concepts. Applications may not substitute other terms of the same concept in the Context Group. Applications may not add a term that means "unspecified" or "missing" or "unknown" similar; if such a concept is intended to be permitted then the Standard will include it in the Context Group already. Such extension may be made without a change in Context Group Identifier, but with the specification of Context Group Extensions (see <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>).</para>
                <para xml:id="para_ee77a9cf-af37-42f7-80d7-a0ef7c2c1ac6">Non-extensible Context Groups shall not be modified in an application.</para>
                <note>
                    <para xml:id="para_4f233c9e-3c13-44bd-a0b7-5309590bc31e">The set of concepts in either an Extensible or a Non-extensible Context Group may be changed in subsequent editions of the Standard, in accordance with the procedures of the DICOM Standards Committee.</para>
                </note>
            </section>
        </section>
    </chapter>
    <chapter label="8" status="1" xml:id="chapter_8">
        <title>Coding Schemes</title>
        <para xml:id="para_389c3616-61ec-4445-b4a6-bd40edcf86f9">
            <xref linkend="table_8-1" xrefstyle="select: label nopage"/> lists the Coding Schemes (and their designators) defined for use in DICOM; <xref linkend="table_8-2" xrefstyle="select: label nopage"/> lists the HL7v3 Coding Schemes referenced for use in DICOM. Additionally, any Coding Scheme may be used that has an entry in the HL7 Registry of Coding Schemes (HL7 v2 Table 0396, or the equivalent online registry), in which case the HL7 Symbolic Name shall be used as the value for the Coding Scheme Designator in DICOM, as long as it does not conflict with an entry <xref linkend="table_8-1" xrefstyle="select: label nopage"/> and fits within the Value Representation of the DICOM Coding Scheme Designator (0008,0102) Attribute. As specified in the HL7 v2 Table 0396, local or private Coding Schemes shall be identified by an alphanumeric identifier beginning with the characters "99".</para>
        <note>
            <orderedlist>
                <listitem>
                    <para xml:id="para_cc4a48c8-1017-4297-9ff1-d7d8ebb3ead3">An earlier version of this table was formerly contained in Annex D of <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>.</para>
                </listitem>
                <listitem>
                    <para xml:id="para_52df67de-c471-4ad4-94da-5ac277cdebe3">See <olink targetdoc="PS3.3" targetptr="sect_8.2" xrefstyle="select: docname label quotedtitle"/> for further description.</para>
                </listitem>
                <listitem>
                    <para xml:id="para_6461d581-c2c5-4dc8-9730-71116443a794">The Coding Scheme UIDs are provided for reference only; the normative specification of UIDs and their associated meaning is the responsibility of the Coding Scheme developer and/or HL7.</para>
                </listitem>
                <listitem>
                    <para xml:id="para_516c76b9-945d-48c8-9eae-1821a106ad56">The current version of HL7 v2 Table 0396 is available at <link xl:href="http://www.hl7.org/special/committees/vocab/table_0396/index.cfm"/>.</para>
                </listitem>
                <listitem>
                    <para xml:id="para_b097aaca-ae03-4c14-93b8-30c08ff52f36">The HL7 registration of Coding Schemes is available at <link xl:href="http://www.hl7.org/oid/index.cfm"/>.</para>
                </listitem>
                <listitem>
                    <para xml:id="para_5e031914-1c51-4e0e-9f1d-f47d3a51a92d">Publication of codes or references to Coding Schemes within DICOM does not constitute a grant of intellectual property rights to implementers. Use of some Coding Schemes may require a license, or purchase of the relevant Coding Scheme publication. Implementers should consult the relevant Coding Scheme publisher; see also <xref linkend="chapter_2" xrefstyle="template:Section %n"/>.</para>
                </listitem>
                <listitem>
                    <para xml:id="para_15efede3-2b6a-4977-b29a-19c2ed067ff6">The values of Coding Scheme Name (0008,0115), Coding Scheme Responsible Organization (0008,0116) and Coding Scheme Resources Sequence (0008,0109), if available, may be used to fill the corresponding optional Attributes of the Coding Scheme Identification Sequence (0008,0110) in the <olink targetdoc="PS3.3" targetptr="sect_C.12.1" xrefstyle="select: docname label quotedtitle"/>.</para>
                </listitem>
            </orderedlist>
        </note>
        <table frame="box" label="8-1" rules="all" xml:id="table_8-1">
            <caption>Coding Schemes</caption>
            <thead>
                <tr valign="top">
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_5ab47e20-56a9-4356-aa18-622a6f09a5a5">Coding Scheme Designator (0008,0102)</para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_392f55a3-f29a-44ca-a7a9-89367a39f630">Coding Scheme UID (0008,010C)</para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e1ebd38e-42a4-4cee-893f-4d94b6cda509">Coding Scheme Name (0008,0115)</para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6c129c67-2d60-4b3f-90ee-9d360c87dfb4">Coding Scheme Responsible Organization (0008,0116)</para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_1aba1229-a828-4944-a5a1-0d7f5ee47291">Coding Scheme Resources Sequence (0008,0109) Type: URL</para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_fe5d74ea-0181-4ede-aebd-1dd601771111">Description</para>
                    </th>
                </tr>
            </thead>
            <tbody>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_3033a660-ccf2-408d-9c44-3bf1c38b57f3">ACR</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2a78e2af-579c-42bb-96d7-adf8a53d8be6">2.16.840.1.​113883.6.76</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_05b03eb7-cfe0-4f88-96cf-16146e4525c5">ACR Index</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_25c9bf13-bd43-476e-b209-c110d368eab1">ACR</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e22105ad-020d-4296-82a4-15c3401e4d5d"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_15d404c3-c3af-4cbe-bcca-ee209158af0c">ACR Index for Radiological Diagnosis Revised, 3<superscript>rd</superscript> Edition 1986</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_80f802aa-6a0d-49c3-8ef1-0fca7f010372">ASTM-sigpurpose</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7eb949c2-012f-4af3-8f44-18e9cf645dac">1.2.840.10065.​1.12</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d7c2c733-27c6-4a6b-8d67-4d917477108d">ASTM E 2084</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_606ae2d4-016a-4841-968e-cf8c22af87dd">ASTM</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7df581d1-98d3-4a07-85ca-08d01d96b3a1"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bdb1db97-9bc5-48e5-a31a-a3e2deafbd25">
                            <xref linkend="biblio_ASTM_E2084_00"/> Signature Purpose codes (see Annex A1 of ASTM E 2084), ASTM Subcommittee E 31.20 Data and System Security for Health Information</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e71beb37-4ed2-4fba-a6fc-39c6bcc3b2b0">BARI</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_75a442b4-bbde-45bc-b73b-9648662eb889"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3b94a643-b74e-45bf-8591-0a6ccfb98e51">BARI</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_663679db-83dc-4c23-a1c3-64e906905ffa"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_aee84a85-2e7f-4176-bb19-d13418146774"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b247fe92-4604-4fbe-b969-b6a7f8d3f902">Bypass Angioplasty Revascularization Investigation<xref linkend="biblio_Alderman_1992"/>; endorsed by ACC/AHA Guidelines for Coronary Angiography<xref linkend="biblio_Scanlon_1999"/>.</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_15e30612-6273-4830-8cc0-8c23e966d5e1">BI</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_165af34b-52d2-49b6-96bf-d71498b60da7"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d8bb59c4-1521-4896-8056-b85839b656bb">BI-RADS</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_00f2d181-9b7f-4147-8f82-4d5307952a31">ACR</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1955332e-fc42-46e2-8a0a-bb4d75c6b1ee"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_668bc3e8-4701-41c8-8a8a-52585272c34f">ACR Breast Imaging Reporting and Data System <xref linkend="biblio_BIRADS"/>, Coding Scheme Version (0008,0103) is required; Code Values are section and paragraph identifiers within the publication where the code meaning is defined (e.g., "I.D.1", where I = Breast Imaging Lexicon, D = Special Cases, 1 = Tubular Density, as the Code Value for "Tubular Density").</para>
                        <note>
                            <para xml:id="para_113d2707-dbb6-4285-ae29-00f3a763ea78">In the HL7 registry, the abbreviation BI is assigned to a different Coding Scheme, specifically the Beth Israel problem list.</para>
                        </note>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_1511f9ab-784b-4c8a-8547-8820c8a0ad41">C4</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a747298a-851a-46d7-8a4c-d5ac3a800858">2.16.840.1.​113883.6.12</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0737ba2e-b83e-4f4f-ae3f-df9e462b5e39">CPT-4</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4be1474f-f0c5-470c-8fa7-622d9b855e7c">AMA</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_662f8f5a-ab65-41b5-b7aa-6e276a4ee147"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2753aeea-6f7b-4d93-b0e5-c5ad6ecc7e5b">American Medical Association's Current Procedure Terminology 4 (CPT-4)</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_98859b86-2395-4d1c-bc68-5aab3ad4f276">C5</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d4a4a025-b4fc-4740-aaea-f40e6e037101">2.16.840.1.​113883.6.82</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f84483d0-6133-49b4-9fa3-b31b7b92f028">CPT-5</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_23f3b222-0dbc-42b7-a4e9-79c194715c31">AMA</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_cb03a9c7-aada-437e-a3f3-269e87345802"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_795bff8f-709f-4a71-a85f-d9de830904fc">American Medical Association's Current Procedure Terminology 5 (CPT-5)</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_f26e317d-c2d7-467e-a04d-b1af30b62905">caDSR</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c90df0d4-289a-445c-943c-342596c84123">2.16.840.1.113883.3.26.2</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b67470ef-98af-4fe7-a03c-5e2ad7352b2f">Cancer Data Standard Repository</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e4d66265-0e33-44ef-b508-0bd66760be28">NCI</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_511a5ae1-ebe5-455e-b7cf-b36753ed234e"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_cb3f1111-906f-41db-8bd1-0a2b13ef78f0">The Public ID is used as the Code Value.</para>
                        <para xml:id="para_c77ed754-1661-449c-94bb-a2fa37cea269">These can be looked up as in the following example (the version is required): <link xl:href="http://cdebrowser.nci.nih.gov/CDEBrowser/search?dataElementDetails=9/&amp;cdeId=2178693&amp;version=2.1&amp;PageId=DataElementsGroup">http://​cdebrowser.​nci.​nih.​gov/​CDEBrowser/​search?​dataElementDetails​=​9/​&amp;cdeId=2178693&amp;​version=2.1​&amp;​PageId​=DataElementsGroup</link>
                        </para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_1978a1af-6e87-48a5-bfaa-d187c6d6fa82">CD2</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_04307da3-eed3-4174-975a-46b950fdd5b0">2.16.840.1.​113883.6.13</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_418dd51b-670a-4186-9b8d-c3444269865c">CDT-2</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f5dd6781-0d23-4d58-8dd1-c354bd721936">ADA</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_276e211e-51e5-4d1b-b835-b418f85d35ac"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d0f4d907-eaf9-47e7-9bef-42255bd77936">American Dental Association's (ADA) Current Dental Terminology 2 (CDT-2)</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a1a516e3-15b0-4e06-9629-f34765f1ac0e">CTV3</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_eb92df37-8165-4371-9686-f94267f03261">2.16.840.1.​113883.6.6</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0f877111-93fc-4198-9e3d-3660540e6b21">Clinical Terms Version 3</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_aa02a4df-b73c-4d42-8788-9e7c7a51a3b9">UK NHS</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4b404dc6-5d12-401d-9e1f-6cb4a79c17d9"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9b56d17b-de54-4954-a0ca-e237476e05ef">Read Codes</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_5c880be2-edd1-4255-98cf-428536e1514b">DC</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1bdf2d4e-20da-4def-bbf9-3e4bab90e2b7">1.2.840.10008.​2.​16.​10</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2cf67aa7-8948-423c-9385-7ce8da7c431d">Dublin Core</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2a44b102-6ad8-4228-9698-0e6cf9442753">W3C</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1bd332f7-461e-4477-a184-61f5731c7885">DOC: <link xl:href="http://dublincore.org/documents/1998/09/dces/">http://​dublincore.​org/​documents/​1998/​09/​dces/</link>
                        </para>
                        <para xml:id="para_f0ba02f3-96d2-490c-8bda-6dab2b6a4c9a">DOC: <link xl:href="http://www.ietf.org/rfc/rfc2413.txt">http://​www.​ietf.​org/​rfc/​rfc2413.txt</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_69614d15-e03c-400b-9fb1-e303eeb8bc7a">Dublin Code Metadata for Resource Discovery. The Code Value is the Label field, e.g., "Creator" (capitalization significant).</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_599bd347-2d3d-4c05-98ee-1848a70e6ddb">DCM</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8d6b9ab1-e4ba-43df-ae30-b17da46a48f8">1.2.840.10008.​2.16.4</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_46a88dfb-21d2-4f70-8a12-b5d7bb73cd9d">DICOM Controlled Terminology</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6f48b8fb-96b9-41b8-a35f-3221356cd7c4">DICOM</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4bb030d2-c8d2-4725-884e-710314d1330b">DOC: <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/chapter_D.html">http://​dicom.​nema.​org/​medical/​dicom/​current/​output/​chtml/​part16/​chapter_D.html</link>
                        </para>
                        <para xml:id="para_eebcffa1-6286-4d39-92d9-85f2087ebfe4">OWL: <link xl:href="ftp://medical.nema.org/MEDICAL/Dicom/Resources/Ontology/DCM/dcm.owl.zip">ftp://​medical.​nema.​org/​MEDICAL/​Dicom/​Resources/​Ontology/​DCM/​dcm.owl.zip</link>
                        </para>
                        <para xml:id="para_df85047d-377c-46e8-bed1-8201ce197550">FHIR: <link xl:href="http://dicom.nema.org/resources/ontology/DCM">http://​dicom.​nema.​org/​resources/​ontology/​DCM</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4754d612-1da1-45e4-89f2-8755322b5e6c">PS3.16 Content Mapping Resource, Annex D<!--<xref linkend="chapter_D" xrefstyle="template:Annex %n"/>--> (Note that HL7 also specifies an OID of 2.16.840.1.​113883.6.31, but deprecates it in favor of 1.2.840.10008.​2.16.4).</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_f2042a19-2050-4caf-87ef-c451a8a1b660">DCMUID</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6738fd82-0b76-4560-84fd-fed1e086b105">1.2.840.10008.​2.6.1</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_998a5a26-c98f-4e97-809a-fce159612ed1">DICOM UID Registry</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_350a2cd4-c923-43be-86a2-3a37879426ab">DICOM</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c60f1bd8-a1a8-4117-8f51-d4a1339e973f">DOC: <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part06/chapter_A.html">http://​dicom.​nema.​org/​medical/​dicom/​current/​output/​chtml/​part06/​chapter_A.html</link>
                        </para>
                        <para xml:id="para_2034dd5e-3360-4c2d-a7b5-280c8d11567c">FHIR: <link xl:href="http://dicom.nema.org/resources/ontology/DCMUID">http://​dicom.​nema.​org/​resources/​ontology/​DCMUID</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9a3be5c6-0bab-4de5-a285-6a2b9c0351a6"/>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_0bd4ce5d-1db0-4e09-b316-61a14acb1fe0">FMA</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_dcac1af0-b15a-4777-b7e9-5f0415d297ed">2.16.840.1.​113883.6.119</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_974bb051-f8ff-4526-8826-a1fd2f2640ce">FMA</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6539c1e1-0657-4a6c-ae02-c8d8bdd0a7c6">University of Washington, Seattle</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4e34fe75-ca15-467c-931c-16e02e94acac">DOC: <link xl:href="http://sig.biostr.washington.edu/projects/fm/AboutFM.html">http://​sig.​biostr.​washington.​edu/​projects/​fm/​AboutFM.​html</link>
                        </para>
                        <para xml:id="para_152b6faf-6aad-4832-9274-2649fd1e20fc">OWL: <link xl:href="http://sig.biostr.washington.edu/share/downloads/fma/release/latest/fma.zip">http://​sig.​biostr.​washington.​edu/​share/​downloads/​fma/​release/​latest/​fma.​zip</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c7ca237e-be9c-4b73-9ce8-203c5fe4f80e">Digital Anatomist Foundational Model of Anatomy</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_d78d9db4-fb87-4234-9a1e-96fb9e515a2c">HPC</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_772b78c9-de3e-4b7f-ab8e-a83128d75dc2">2.16.840.1.​113883.6.14</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_664f254c-c7c8-4f10-bcab-66afc7ae5242"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_77c82eb6-e7e5-4d2e-920b-dbe9edb743fd"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_94022183-545a-4cea-be3b-44db926e62b4"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_357d8991-81ac-493e-bef8-77dbc82812af">Healthcare Financing Administration (HCFA) Common Procedure Coding System (HCPCS)</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e9fdce30-cc49-4d18-8fab-7ef3e031ddbc">I10</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5df40702-2f61-4f84-8cdb-9e41463eb92a">2.16.840.1.​113883.6.3</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b8bb7ff2-154a-4ef4-97c9-b2cf376d9ab1">ICD-10</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_42b55d39-2a6e-49cd-a697-18d31bc1e08b">WHO</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6e63ba13-af62-4ac0-aa6d-9fa379ac9eab"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f3d3c8b7-2a3f-4d92-9c91-8ef4f08be1e9">International Classification of Diseases revision 10 (ICD-10)</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_9a2c148c-40eb-4a76-8db9-6b8b4d41a858">I10C</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0f1483be-92e7-41ee-9b1e-13f82808bb23">2.16.840.1.113883.6.90</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_25629e2a-754f-4b99-bd85-064fdd59d68d">ICD-10-CM</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4647ccc6-df25-49de-9334-ca98700c7e90">US DHHS CDC</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_02d74552-6846-471e-8c1a-521b8e3ccc4f">DOC: <link xl:href="http://www.cdc.gov/nchs/icd/icd10cm.htm">http://www.cdc.gov/​nchs/​icd/​icd10cm.htm</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a6ac5022-74a1-4cb5-a18e-66e20eb5fef7">International Classification of Diseases, Tenth Revision, Clinical Modification</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_fbe49844-0fb1-421a-bc4a-459a3f614b58">I10P</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a4c28077-bdc7-470c-bb14-5f3635ce8bb5">2.16.840.1.​113883.6.4</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7b695fa9-9766-4080-b02c-9389b37a260f">ICD-10-PCS</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7de97def-be0b-43a4-a78a-53c5f53b6c69">US DHHS CMS</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e4819cf9-5d6d-484c-8769-af19817ecd6d"> DOC: <link xl:href="http://www.cms.gov/Medicare/Coding/ICD10">http://www.cms.gov/​Medicare/​Coding/​ICD10</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f5aa69de-ac30-44d4-a503-951e9138daea">ICD-10 Procedure Coding System (ICD 10 PCS)</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_5a18847f-adb9-41dc-93a3-ca40e214cdb5">I11</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_617e0b73-f67e-4e6f-b45e-00d962997165">1.2.840.​10008.2.​16.​16</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3d61013b-f31d-404b-a06e-6540e24a500f">ICD-11</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f0eb58c5-016d-43e3-8f28-676192715d20">WHO</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ede015fe-40f2-4c18-94cd-f600cae795e3">DOC: <link xl:href="http://icd.who.int/browse11/l-m/en">http://​icd.who.int/​​browse11/​​l-m/​​en</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6da70f9c-47b4-42fa-9d36-3c3b39519ea6">International Classification of Diseases revision 11 (ICD-11)</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_3b027c1b-fa9f-4316-a533-38e98f621177">I9</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4868c6d7-1767-47e4-878c-236ae021608d">2.16.840.1.​113883.6.42</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_37ef7160-f5f1-44f5-9d3b-8dbd4d7b7a4b">ICD-9</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0a6ee811-f689-422e-bc17-10fef9ee314d">WHO</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_278027b6-ed96-4676-9ce8-34f727396140"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6c8e22e7-11d7-42d4-9a90-f5d69ce97a5f">International Classification of Diseases revision 9 (ICD-9)</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c7e37357-aec2-4a68-beb3-57f7e93fa269">I9C</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_93bc981f-5961-4ae8-b535-508a2e67cd68">2.16.840.1.​113883.6.2</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f6aba632-3ca4-4b1a-9500-e5cd927bc2c1">ICD-9-CM</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b0e2636d-d9ca-4490-9f2c-ae739aa1bcc0"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_aece2ca8-5c13-4794-91fb-5cc76ac58d5e"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6783c5d9-254d-469c-965f-1d5b1d1d531c">International Classification of Diseases revision 9, with Clinical Modifications (ICD-9-CM)</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_b4bf632b-8b88-4bd5-8c65-99d8b3113f7d">ICDO3</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_67ab4c69-5935-491e-b8e2-55a1edd521e9">2.16.840.1.113883.6.43.1</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b08b49ee-2c8f-453a-9cc2-f2f04da34b40">ICD-O-3</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3cd12934-833b-4c1d-905e-a53710549127">WHO</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_91ea83b3-a5d1-4b08-8f96-77acc12450f6">DOC: <link xl:href="http://www.who.int/standards/classifications/other-classifications/international-classification-of-diseases-for-oncology">http://www.who.int/​standards/​classifications/​other-​classifications/​international-​classification-​of-​diseases-​for-​oncology</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d759eb53-6c6e-4296-bc8c-7614be9dcfc8">International Classification of Diseases for Oncology, 3rd Edition</para>
                        <note>
                            <para xml:id="para_fb6c205e-97b2-4f2f-8c7b-f948a6bb0458">ICD-O-3 version 3.2 is described at <link xl:href="http://www.iacr.com.fr/index.php?option=com_content&amp;view=article&amp;id=149">http://www.iacr.com.fr/​index.php?​option=com_content​&amp;view=article​&amp;id=149</link>.</para>
                        </note>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_12cf0374-7b5d-4607-b67b-7d1f5b537a82">IBSI</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_43363310-4d7f-488d-99a3-274d91b044c7">1.2.840.10008.2.​16.​13</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_58540735-2ccf-4d0f-a5cf-ae5c9e2ccdaa">Image Biomarker Standardisation Initiative</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_146f6373-c482-4540-80f8-3afd332b29a8"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_cd7a0ee0-1b67-4e90-ab91-8db9730072e0">DOC: <link xl:href="http://arxiv.org/abs/1612.07003">http://​arxiv.org/​abs/​1612.07003</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a9dda21c-4d4a-4d00-b261-9912b594b760"/>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c11f058c-0368-495a-938f-a5fcacb08e85">IETF4646</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_dc0cf208-e2ef-48f2-a640-47e0c049afb4"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_eb90a561-1266-426b-9370-44f144cbde4f">RFC 4646</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a33e4328-28d5-4f7e-a08c-d0fbc124c8bf">IETF</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_19013679-015a-4930-9c3b-276bff8f5a83">DOC: <link xl:href="http://tools.ietf.org/html/rfc4646">http://​tools.​ietf.​org/​html/​rfc4646</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0f05c133-1eb5-4d2c-b94e-3e73f9f61ec5">
                            <xref linkend="biblio_RFC_4646"/>, Tags for Identifying Languages, The Internet Society (2005)</para>
                        <para xml:id="para_7444ff49-f95a-41ef-8ca1-efa4720ed318">
                            <xref linkend="biblio_RFC_4646"/> has been superceded by <xref linkend="biblio_RFC_5646"/>.</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_d713a9b2-febe-4e9f-951f-f4a502efd1d7">ISO639_1</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a0b358aa-0556-449a-af96-399375da24df">2.16.840.1.​113883.6.99</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2ff0e46d-aaaf-4ebc-b2cc-2eacf65ed283">ISO 639-1</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_07039b6a-8f30-4a5b-8d4d-2ab40a648ad4">ISO</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_dc389902-74bf-4ef1-98e0-0b689d613ac7"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_433d6ab1-5902-453c-8e46-7f799ff853a7">
                            <xref linkend="biblio_ISO639-1"/> Two-letter language codes</para>
                        <note>
                            <para xml:id="para_593554e7-779b-46a9-b55e-d76d48024a5b">HL7 uses "ISO639-1" for the symbolic name, with a hyphen rather than an underscore</para>
                        </note>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_10afe20d-10da-4354-9cf5-0578b489fdcd">ISO639_2</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d1300dbc-800d-4549-93f0-ee2332bc6f45">2.16.840.1.​113883.6.100</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bf6c7d64-e849-45e9-a9bc-d15fbd71aeb8">ISO 639-2</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d4c87c9e-c881-46e6-9304-7196f84bb20f">ISO</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b782c133-a815-4be5-a5f7-8cce4ac35d1a"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a5eb0d95-96f6-4827-8921-141dec3f63a9">
                            <xref linkend="biblio_ISO639-2"/> Three-letter language codes</para>
                        <note>
                            <para xml:id="para_f5e803b1-4ce7-4d81-ac76-2d2579cb398a">HL7 uses "ISO639-2" for the symbolic name, with a hyphen rather than an underscore</para>
                        </note>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_53415a20-74f3-4a13-8dcd-95a9f95d662f">ISO3166_1</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_78c7cece-432b-4bc1-aa89-a0b95145394e">2.16.1</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ca7112e3-13be-4e82-b8db-10edd511cb65">ISO 3166-1</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_094e68ed-1ed0-4c64-b021-255131ab10d8">ISO</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_19088863-349f-4ff7-863b-34cb61c26eb2"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_90266c3b-307a-4fc3-ae62-ec78e107c592">
                            <xref linkend="biblio_ISO3166-1"/> alpha-2 Country Codes</para>
                        <note>
                            <para xml:id="para_17dd51c2-efb6-42ce-a433-6f6adb5809b9">HL7 uses "ISO3166-1" for the symbolic name, with a hyphen rather than an underscore</para>
                        </note>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_b1ebf28a-8244-442c-8015-7f6477f4123a">ISO5218_1</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f06f32db-87d3-4ebb-b947-e946c4915236"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_eb717905-b5db-4710-9244-28c77a3787d4">ISO 5218-1</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_21834c89-2788-48c4-b2be-8241bd8b3980">ISO</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1e5c0035-1c32-4911-8611-53811efca519"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a4bd9806-f058-482c-8653-4f76a89339d8">Representation of Human Sexes (not used)</para>
                        <para xml:id="para_af4cc35c-1870-4e06-8b54-b1369f018726">ISO5218_1, which uses numeric codes, was improperly specified in CID 7455 Sex in earlier editions of the Standard. The alphabetic codes improperly attributed to that Coding Scheme have been added to the DICOM Controlled Terminology, and thus all references to Coding Scheme ISO5218_1 should be considered equivalent to Coding Scheme DCM.</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_be132a7a-a4c9-40ce-b654-959c1bdaa79b">ISO_OID</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2a97313e-6666-449a-9701-fb2ebe57d829"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b2cea612-8fee-48b6-974f-91447c44a8e4">ISO OID</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0060db75-1a59-469f-bcbf-51d5f9c675cb">ISO</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e2f1bd5c-5ba0-4456-aa7f-a75f7d3e7478"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ef53f5d5-f9c4-455c-aca3-434c34a1b927">
                            <xref linkend="biblio_ISO8824-1"/> ISO/IEC 8824-1- Information Technology - Abstract Syntax 1 (ASN.1): Specification of Basic Notation, and <xref linkend="biblio_ISO9834-1"/> - Information technology - Open Systems Interconnection - Procedures for the operation of OSI Registration Authorities: General procedures and top arcs of the ASN.1 Object Identifier tree</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_af9582a8-03f8-4cb1-955f-20e0515e1817">ITIS_TSN</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_700b353a-ccf8-4564-85d2-90fc01ccae68">1.2.840.10008.​2.​16.​7</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b3653547-3b6d-4d9b-bdc9-f249c3fa8dc4">ITIS TSN</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a46a3d2f-d956-45d1-b8fa-772af7b82c40">ITIS</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f8621212-1d91-4209-bd68-ea7558093534">DOC: <link xl:href="http://www.itis.gov">http://​www.​itis.​gov</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3ae5af2d-d44e-40b9-88e4-9959437822be">A Taxonomic Serial Number (TSN) is a unique, persistent, non-intelligent identifier for a scientific name in the context of the Integrated Taxonomic Information System (ITIS).</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_60695b70-1bb1-47fb-ada1-bdcc9888611e">LN</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_142b33e9-d458-4a20-91db-30e265a4d87f">2.16.840.1.​113883.6.1</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e4c3160b-d179-4f6e-b3ab-1863f5a05bae">LOINC</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_aa1e00cc-d4cc-417f-954a-da9e4aaae29d">Regenstrief Institute</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ddc4a5ac-f244-454d-833e-b8ae46b5121c">DOC: <link xl:href="http://loinc.org/">http://​loinc.​org/</link>
                        </para>
                        <para xml:id="para_43f263f2-ed75-47e0-891a-faa3d7051a2e">FHIR: <link xl:href="http://loinc.org">http://​loinc.​org</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9c340b04-01a6-4093-b467-1e6aa6eb31fb">
                            <xref linkend="biblio_LOINC"/> Logical Observation Identifier Names and Codes</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_1fa22a09-5215-4bf5-ab84-90e65dba3959">MA</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b1a97d93-cb0a-4139-beac-cba13087a19b">1.2.840.10008.​2.​16.​5</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_cc59220a-e8cc-4a45-8e3b-89cc97fccfde">Adult Mouse Anatomy Ontology</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_780efd84-17c8-488a-b6b6-ad4b496a2223">The Jackson Laboratory</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_148fb9bf-1f2a-47db-a303-b139f986d8ba">DOC: <link xl:href="http://www.informatics.jax.org/searches/AMA.cgi?id=MA:0002405">http://​www.​informatics.​jax.​org/​searches/​AMA.​cgi?​id=MA:0002405</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7232de4a-f4ef-4f49-bb56-46effe260107">Hayamizu TF, Mangan M, Corradi JP, Kadin JA, Ringwald M. The Adult Mouse Anatomical Dictionary: a tool for annotating and integrating data. Genome Biology 2005;6(3):R29. doi:10.1186/gb-2005-6-3-r29. <link xl:href="http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1088948/">http://​www.​ncbi.​nlm.​nih.​gov/​pmc/​articles/​PMC1088948/</link>
                        </para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a8d7480b-84dc-466b-9366-ff792ed169e8">MAYOASRG</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f200dba5-fc29-4bd3-a70c-e8c74de47ab1">1.2.840.​10008.2.​16.​12</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bd2a4662-0ae2-4473-ae47-bd1c37098ba5">Mayo Clinic Non-radiological Images Specific Body Structure Anatomical Surface Region Guide</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3cd7e3aa-ca18-4854-97da-1ead1b85c1bf"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9780e7e9-896a-4e4c-8846-47eabd27b8da"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f5c1eca0-dd4d-4d0e-aa54-a589fe50a072">The numeric code of entries in the Mayo Clinic Non-radiological Images Specific Body Structure Anatomical Surface Region Guide.</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_73b60864-8ca0-4810-a354-562f9514ceab">MDC</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f35c7da2-055f-4d4d-a7f1-2194947e2417">2.16.840.1.​113883.6.24</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0ae9cfd0-1d21-4801-a852-48d4a185a649"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4b2e2778-20a7-4a9d-aac8-9646b212aea6"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3e4765d4-7484-4eaa-861a-87b636a58ba4"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a1e7e245-a066-44a4-b48a-8a56e2290a4f">ISO/IEEE 11073 Medical Device Nomenclature, including all its subsections (<xref linkend="biblio_ISOIEEE_11073_10101"/>, <xref linkend="biblio_ISOIEEE_11073_10101a"/>, <xref linkend="biblio_ISOIEEE_11073_10102"/>, etc.), encoded as decimal strings &lt;partition&gt;:&lt;element&gt;</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_b889e1ca-499b-46d9-9c07-54b066c680eb">MDNS</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_83a261fa-dc64-4363-86d1-f3cb95667036"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3f3cef8d-514f-45e8-b3f4-dee365fe99b5"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1ffe53b7-511b-4a0e-9fb8-41f565c36084"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4497f109-6e30-4e41-ad4d-621d3db31ee6"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_794aacba-100b-411e-9475-21ba857c6f2b">Universal Medical Device (UMD) Nomenclature System</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e0247b36-d540-4c77-af02-524ca56707e7">MGI</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4481161a-f48b-46df-92e3-95cc1d0feca6">1.2.840.10008.​2.​16.​8</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_cff43161-8e82-4307-ba22-728c6a55c41e">MGI</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ea4fb86d-53ee-44cc-ab98-0bd592ea4743">The Jackson Laboratory</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ac234309-fa4d-4160-a8d1-19673a3e21d3">DOC: <link xl:href="http://www.informatics.jax.org/mgihome/nomen/">http://​www.​informatics.​jax.​org/​mgihome/​nomen/</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fb70c93d-3fc1-489d-ba6b-e1549061b02f">The MGI ID from the Mouse Genome Initiative (MGI) nomenclature.</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a6536c91-84bf-42d8-8f32-dede9c39ba78">MSH</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1d35251c-c98c-420b-82cf-9badd1a6136c">2.16.840.1.​113883.6.177</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b86ea0b3-e46d-4e44-ab11-7a2f2a0360f6">MeSH</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f3960c42-7c72-40a7-a166-2805681d0a3f">NLM</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e7aafe5f-ff8f-44dc-99f8-eef8f70fb446">DOC: <link xl:href="http://www.nlm.nih.gov/mesh/meshhome.html">http://​www.​nlm.​nih.​gov/​mesh/​meshhome.​html</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_27df907a-7624-482f-867b-64d665ca0b91">US National Library of Medicine (NLM) Medical Subject Headings (MeSH)</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_504db674-aaf8-45ea-97f2-7b3c56c0032c">NBD</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_23a2147e-724f-41f6-a7d6-82c5bfe7958e">2.16.840.1.​113883.15.2</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d7d2b193-1502-4846-8b28-98dfef9a280c"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fa10beba-1db1-461a-838b-72590c427b03"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8a439e66-8275-4fd4-8267-862e30afe232"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_da1651b5-2860-407f-9b50-e4920efcb365">NASPE/BPEG Defibrillator Code</para>
                        <para xml:id="para_2ad2417f-4cab-45c4-8713-e2688f662279">Bernstein AD, et al."The NASPE/BPEG Defibrillator Code" PACE, 16:1776-1780, 1993</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_cd9a0912-e429-4aeb-821c-077b3ec7333f">NBG</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6d34be40-a1b6-4e38-8ac0-3075bd9ac0fb">2.16.840.1.​113883.15.3</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b28854ae-5427-43ec-bde3-8f64168bd2f7"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_526d17ee-632c-4f66-9987-b07e3133ac5d"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <!-- zero width spaces in rendered link before hyphens are to avoid too wide a table cell -->
                        <para xml:id="para_79af84ed-601f-4159-898d-bbe2eede3c84">DOC: <link xl:href="http://www.hrsonline.org/Practice-Guidance/Clinical-Guidelines-Documents/2002-The-Revised-NASPE-BPEG-Generic-Code-for-Antibradycardia-AdaptiveRate-and-Multisite-Pacing">http://www.​hrsonline.​org/​Practice-​Guidance/​Clinical-​Guidelines-​Documents/​2002-​The-​Revised-​NASPE-​BPEG​-​Generic-​Code-​for-​Antibradycardia-​​AdaptiveRate-​and-​Multisite-​Pacing</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d31e4c28-22a7-467a-b56b-bfde48ce43a9">NASPE/BPEG Generic Pacemaker Code (2000)</para>
                        <para xml:id="para_e5fc8012-d679-46f7-9cb0-362c9c4d0bae">Bernstein AD, et al."The Revised NASPE/BPEG Generic Code for antibradycardia, adaptive-rate, and multisite pacing." Pacing Clin Electrophysiol., 25:260-264, 2002</para>
                        <para xml:id="para_21e5be38-844f-461a-ba4e-c987063a592d">See <link xl:href="http://www.hrsonline.org/Practice-Guidance/Clinical-Guidelines-Documents/2002-The-Revised-NASPE-BPEG-Generic-Code-for-Antibradycardia-AdaptiveRate-and-Multisite-Pacing">http://​www.​hrsonline.​org/​Practice-​Guidance/​Clinical-​Guidelines-​Documents/​2002-​The-​Revised-​NASPE-​BPEG​-​Generic-​Code-​for-​Antibradycardia-​​AdaptiveRate-​and-​Multisite-​Pacing</link>.</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_16f49365-17ef-4fec-bbb0-f0552ee44a9d">NCDR</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_17e93137-0523-448c-99b5-4788609c1666"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c8d8c781-76a4-4360-a4f1-5a3c792950e3"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_54f4f34d-341c-420b-b5c6-37698bb25eae"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_dddc9857-b374-4303-8524-45befe0da93b"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5844c08f-558c-4a35-9a26-176819bbcf21">American College of Cardiology National Cardiovascular Data Registry™ Cath Lab Module Version 1.1, 1997; Version 2.0b, 1999</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_d5493b38-f911-4441-9a8e-8a0fc9ea3f09">NCIt</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a1acbf1b-d06b-473d-b139-b6dc1819ba8c">2.16.840.1.​113883.3.26.1.1</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_78e312fa-080e-49d1-b5af-b24e7b922c88">NCI Thesaurus</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_770f3b4d-8a4a-4e0a-89c6-2088f62e847c">NCI</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_077af502-4c8f-4866-b723-065704126d6f">DOC: <link xl:href="http://ncit.nci.nih.gov/">http://​ncit.​nci.​nih.​gov/</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_693dcc8a-a727-4895-803d-2cae6dd21543"/>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_b8452a88-21c5-40c5-8020-d356c3f34648">NDC</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1908be76-070d-4678-8c69-b3a33c3d4a4c">2.16.840.1.113883.6.69</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_74d36a0c-427a-487e-94a5-97fbfa30f123">National Drug Code Directory</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_53c35705-6424-4e1b-ad17-781b891563d8">US FDA</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <!-- zero width spaces in rendered URL for table width-->
                        <para xml:id="para_e47defad-76ed-4171-b9c0-5496f5f9597d">DOC: <link xl:href="http://www.fda.gov/Drugs/InformationOnDrugs/ucm142438.htm">http://​www.fda.gov/​Drugs/​Information​​OnDrugs/​ucm142438.htm</link>
                        </para>
                        <para xml:id="para_c51a698c-86ca-4f19-bd6c-43473085d8c3">DOC: <link xl:href="http://www.hl7.org/fhir/ndc.html">http://​www.hl7.org/​fhir/​ndc.html</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e05b7d2e-a809-4eef-a9a0-4e3bc126d340">The Code Value is the 10 digit 3 segment NDC code with "-" between segments included and no asterisk (leading zero placeholder).</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_8bcbcd97-397b-43fc-ad71-196e04796f6c">NEU</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1a520082-c334-4fb9-ae1f-bb6bb759ca88">2.16.840.1.​113883.6.210</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5ae7e69d-2d51-409c-b4cb-a19fdc7ab5f8">NeuroNames</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7bf57cd9-ca38-427e-95a3-0224d3df6bda"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <!-- zero width spaces in rendered URL for table width-->
                        <para xml:id="para_9a3c3a3d-b193-4a88-aef9-607b6c387f4d">DOC: <link xl:href="http://braininfo.rprc.washington.edu/aboutBrainInfo.aspx#NeuroNames">http://​braininfo.​rprc.​washington.​edu​/aboutBrainInfo.​aspx​#NeuroNames</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_68d52c23-c1a6-4abc-815d-b3fa93857b4f">The numeric brainInfoID is used as the Code Value.</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_f165e510-0f91-4a97-a0d8-49b0468c8c23">NICIP</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6a0edf9f-d128-461f-9fb5-76f4784b4d93">2.16.840.1.​113883.2.1.​3.2.4.21</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_52bfff2c-14aa-4de5-8140-5c0a3b52f225">NICIP</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_cddf4c2b-17c1-43ed-abeb-f39636ff2bda">UK NHS</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <!-- zero width spaces in rendered URL for table width-->
                        <para xml:id="para_cd932d0e-fd22-40d1-a819-eae0ee91231a">DOC: <link xl:href="http://digital.nhs.uk/article/1108/National-Interim-Clinical-Imaging-Procedure-NICIP-Code-Set">http://​digital.​nhs.​uk/​article/​1108/​National-​Interim-​Clinical-​Imaging-​Procedure-​NICIP-​Code-​Set</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_453a5aed-5775-4bc6-a084-62fbb7165baf">UK National Health Service National Interim Clinical Imaging Procedures (NICIP) Short Code (e.g., "CCHAPC" for CT Thorax abdomen pelvis with contrast)</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_f2ae24de-9946-4ac1-a89f-4430317877e3">NPI</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_afd0f233-8568-417a-b2a8-07e56250fd3c"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f04a435a-5d47-4dfb-8c8b-11135e00646a"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4729e218-509f-4ebe-b7d1-9f2f5a55572a"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ba0274d8-23ce-47d6-a30e-443d2097dafe"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b50d09ca-2f56-4801-91c6-7bc203e53a7c">HCFA National Provider Identifier</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_aa331e49-dd87-4924-abb1-a77e6629ddc7">NYUMCCG</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d14cb6e6-02af-4a0e-8ebe-a2add3d76e16">1.2.840.​10008.2.​16.​11</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_aedb0bae-831e-4297-aa67-c8055f81ac5f">New York University Melanoma Clinical Cooperative Group</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_46ee22ea-4b07-4500-8b6f-62d6ba63f473"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b16d2bdf-9baf-4397-91fe-0d530dee4dea">DOC: <link xl:href="http://www.anatomymapper.com/nyu/">http://​www.anatomymapper.com/​nyu/</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_61378386-7bf3-47f1-961d-16c1dd0d203c">The numeric code of entries in the New York University Melanoma Clinical Cooperative Group's numbering system.</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_915604b1-a422-40b3-899d-b03ce9ee65f7">PATHLEX</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0c10b59a-ce0c-410d-bfbd-cab71e55b0be">1.3.6.1.4.1.​19376.1.8.2.1</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ddd71612-c5a5-4972-871d-e3c07df0a5c4">PathLex</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f9ab952c-fa87-4312-a8a2-32a2388c07c8">IHE</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <!-- zero width spaces in rendered URL for table width-->
                        <para xml:id="para_3b1f6c3c-ef2d-46ad-8cc5-1e0305378fab">DOC: <link xl:href="http://www.ihe.net/Technical_Framework/upload/IHE_PAT_Suppl_APSR_Appendix_Value_Sets_2011_03_31.xls">http://​www.ihe.net/​Technical​_Framework/​upload/​IHE​_PAT​_Suppl​_APSR​_Appendix​_Value​_Sets​_2011_03_31​.xls</link>
                        </para>
                        <para xml:id="para_70cc4d8f-7e6b-4ae7-abbf-7f5436f5ab5f">DOC: <link xl:href="http://purl.bioontology.org/ontology/PATHLEX">http://​purl.bioontology.org/​ontology/​PATHLEX</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_32e6194b-deba-46ea-a35a-e5aa6d6f135d">The numeric pathLexCode is used as the Code Value.</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_629af3a9-e55a-47e5-8798-6ea4888f32c6">POS</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7b6db951-8a60-4460-91ac-c50401c09cf7">2.16.840.1.​113883.6.50</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5c1fbfb3-e773-4f48-96c5-f9fea393c1d6"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e16e0835-5809-4662-95ed-f900b9ab9b99"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b4de02a0-4502-44ff-afa0-e1dd405fce98"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9adc41fd-1975-4e9a-b165-8c2f1c4d2922">HCFA Place of Service (POS) Codes for Professional Claims</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_b0155bc8-ece6-4b3b-9d35-14f23a64233d">PUBCHEM_CID</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c3f8d514-1de7-4cab-8dba-8976f8d17652">1.2.840.10008.​2.​16.​9</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e8d35298-c9e2-4c4e-9842-08ae15f62b13">PubChem</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_890272c1-02bb-489b-b7d4-6d7b67f12f7c">NCBI</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <!-- zero width spaces in rendered URL for table width-->
                        <para xml:id="para_a2081c0d-4967-4a19-9e18-330805d68322">DOC: <link xl:href="http://pubchem.ncbi.nlm.nih.gov/">http://​pubchem.​ncbi.​nlm.​nih.​gov/</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_61ee0d9a-f361-4ed9-be35-da9e78388617">US National Center for Biotechnology Information (NCBI) PubChem Compound CID.</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_f568450e-c147-41e3-ba6d-057ffd233e89">RADLEX</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e40c4197-28a1-48bb-a57b-7b2d208b797c">2.16.840.1.​113883.6.256</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fbd796e0-8dfb-49b0-86b6-1f2bf1b6ba71">RadLex</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_98248974-d832-43ef-bbca-4c93949b9435">RSNA</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ff1d5d04-cd69-47ef-be48-f8cb184c19cd">DOC: <link xl:href="http://www.radlex.org/">http://​www.radlex.org/</link>
                        </para>
                        <para xml:id="para_ac84018f-04a2-4ac9-8074-aae1161aa359">FHIR: <link xl:href="http://www.radlex.org">http://​www.radlex.org</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_812b50d0-596c-4b0d-8ea7-c41c6ae0d10d">
                            <xref linkend="biblio_RadLex"/>
                        </para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_1b96d2bc-0349-43fd-908c-90a53ed4f38f">RADELEMENT</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_766212ab-6f95-4366-9b70-77990ebfb8d4">1.2.840.10008.2.​16.​15</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_33303cc4-1714-4c16-a971-db04b1a23292">RadElement</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_abd6cbcd-0290-4c12-a076-7dc44e1b43dd">RSNA</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_da79e6ae-6ee0-401d-b0ca-ad23f4f8eeff">DOC: <link xl:href="http://radelement.org/">http://radelement.org/</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0bbfe37a-511c-4151-b1a5-aba89fa1dd72">
                            <xref linkend="biblio_RadElement"/>
                        </para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e8065511-9b85-4895-8790-d6c8d6fda5bb">RFC3066</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3e655ed7-d7cd-429f-b493-bafe912f4c3c">2.16.840.1.​113883.6.121</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ffe41be2-405e-4d9d-acae-77f63a9c6592">RFC 3066</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f7cad364-2ef2-4bdc-8605-721acfbf2757">IETF</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bf54450a-66e9-487a-94cc-72590b45575c">DOC: <link xl:href="http://tools.ietf.org/html/rfc3066">http://​tools.ietf.org/​html/​rfc3066</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e5b55166-d6c6-4881-9bc3-087dfd8c8ecd">
                            <xref linkend="biblio_RFC_3066"/>, Tags for the Identification of Languages, Internet Engineering Task Force</para>
                        <note>
                            <para xml:id="para_56c2fbde-d413-4886-9e8d-4fefb339663f">HL7 uses "IETF3066" for the symbolic name.</para>
                            <para xml:id="para_079814ee-27a5-4e89-aee3-ff7e777ae6b7">
                                <xref linkend="biblio_RFC_3066"/> has been superseded by <xref linkend="biblio_RFC_4646"/>, which in turn has been superceded by <xref linkend="biblio_RFC_5646"/>.</para>
                        </note>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_bad3a540-f91e-46bd-9d96-b92e6011ca66">RFC-3881</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_130a2e95-11ad-44e3-a18b-68c5e5d1ebd5"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_12212e19-951a-4ae7-81e7-5d38e07e61e9">RFC 3881</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0453d4ee-b458-4a50-847a-bdc875f5c3df">IETF</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a01071ac-6110-40b6-9c27-8e0966f2671c">DOC: <link xl:href="http://tools.ietf.org/html/rfc3881">http://​tools.ietf.org/​html/​rfc3881</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_37adb5ff-76a2-486d-b381-cb9940bb04b3">
                            <xref linkend="biblio_RFC_3881"/>, Security Audit and Access Accountability Message - XML Data Definitions for Healthcare Applications</para>
                        <note>
                            <para xml:id="para_2e1382cd-15b5-431c-8426-9c9a59f83924">A hyphen is used in the Coding Scheme Designator for consistency with historical use in IHE. See IHE ITI TF Vol2a. Section 3.20.7.1.3.</para>
                        </note>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_da712a7d-0164-447d-b754-9fa0fa769236">RFC5646</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_72ce4955-af4d-4b75-a969-4e7144bba83d">2.16.840.1.​113883.6.316</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_aadd81fa-ec81-43b8-b1d6-41413a6628d0">RFC 5646</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_14b0abc5-b402-4364-abe8-8aea93bb5c4d">IETF</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c9b9bd2c-ad9b-4202-843a-41edc9f9da54">DOC: <link xl:href="http://tools.ietf.org/html/rfc5646">http://​tools.ietf.org/​html/​rfc5646</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_deefe804-61ba-4ee3-ad2c-61ddabc053ee">
                            <xref linkend="biblio_RFC_5646"/>, Tags for Identifying Languages, The Internet Society (2009)</para>
                        <note>
                            <para xml:id="para_a250af59-06d0-4ee3-ba55-3edc3be81b08">The HL7 OID Registry specifies "rfc5646", not "ietf5646", as the Desired Symbolic Name (inconsistent with the pattern used for <xref linkend="biblio_RFC_4646"/>).</para>
                            <para xml:id="para_a9ca860c-1ce1-42bc-89ad-7b9d54c358d5">
                                <xref linkend="biblio_RFC_5646"/> constitutes one part of IETF Best Current Practice BCP 47 Tags for Identifying Languages, which also includes <xref linkend="biblio_RFC_4647"/> Matching of Language Tags; <xref linkend="biblio_RFC_4647"/> is not relevant in this context.</para>
                        </note>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_8fef3424-448e-4a64-ad59-a183f9c51368">RO</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6ded0b19-d984-4dc6-a42c-ebfeee3289cb">1.2.840.​10008.​2.​16.​14</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_27cc4051-c6eb-4858-bd33-0db3a5cec90a">Radiomics Ontology</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5c379a82-c979-4d2c-9f2a-d9b4d5c94c3d"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_157496a9-f857-4e06-aa45-0fef896f35fc">DOC: <link xl:href="http://bioportal.bioontology.org/ontologies/RO">http://​bioportal.bioontology.org/​ontologies/​RO</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9ccfd2b2-adf2-4365-9b68-f1a2df6d76c4"/>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_10530c1f-5c16-4dfd-9c88-75df652b6571">RRID</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c72fda9a-d67c-42b6-8dca-9952cb05e9e2">1.2.840.10008.2.​16.​18</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8745d05c-14b8-4f07-b34e-a9d42270d60d">RRID</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_69764b54-d832-4448-a803-028dadaa1e21">Resource Identification Portal Community</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_abfbf723-fdc2-4afd-9a7f-b667380387bc">DOC: <link xl:href="http://www.rrids.org/">http://www.rrids.org/</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9c86f527-50c5-44a4-8949-3cbdd1c6f8a5">Research Resource Identification</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_675069af-76f3-4af6-bed0-e94451cd02fd">RXNORM</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_83ef9527-c4f7-47c8-a2fa-49b065a85055">2.16.840.1.113883.6.88</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_30627f86-084f-4d7b-b515-b966ca6faeef">RXNORM</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7c2c36bb-cc44-4442-ad3a-8a9f560d916c">NLM</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_cda90e16-0333-4feb-88f8-e20c42501f09">DOC: <link xl:href="http://www.nlm.nih.gov/research/umls/rxnorm/">http://​www.nlm.nih.gov/​research/​umls/​rxnorm/</link>
                        </para>
                        <para xml:id="para_4ddc0a0e-0854-4660-bd9b-61db2b667327">FHIR: <link xl:href="http://www.nlm.nih.gov/research/umls/rxnorm">http://​www.nlm.nih.gov/​research/​umls/​rxnorm</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8635ac97-45dd-44ae-8e17-a054cf86abb0">RxNorm provides normalized names for clinical drugs and links its names to many of the drug vocabularies commonly used in pharmacy management and drug interaction software.</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_8c75b6c8-dd44-4f56-b047-011d42e901bd">99SDM</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_dfa2cd1d-3ad7-4267-b802-2dfe5adc6ba8">2.16.840.1.​113883.6.53</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5a05b76e-a79c-470c-b712-9094d52b8b90">SDM</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3d801f17-8aa3-4b7d-8ebc-c6fe3bf94970">DICOM</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4bfe5efc-2b60-4795-a644-e931957e0ace"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0bab8e13-07fe-45d8-8b35-0860a1451ee1">SNOMED DICOM Microglossary (Retired) (see <xref linkend="sect_8.1" xrefstyle="select: label"/>)</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_534e45a1-c802-474d-af08-87a3a04fe98c">SCPECG</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e50f5cea-99e3-406a-b1a8-87e7b189d7c7"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7bfea452-fbe7-4a37-b471-67e4d2674ba4"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_db6fb5a1-8fbc-4c6d-8079-8b5e4b0a9650"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f3ce39ed-1ad8-4486-8d42-adfcba00ddc5"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_40344a84-ec0b-41d4-a680-4054fd83aab3">Standard Communications Protocol for Computer-Assisted Electrocardiography, Draft proposal for ISO Standard, AAMI, Revision 1.3</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_95678825-fc6b-43b0-a514-07b8da6dfa2d">SNM3</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_dc58ae7b-2aea-4758-9b3a-8f72844b042f">2.16.840.1.​113883.6.51</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d247b5b7-1df1-4926-be48-22b9fe47dcb4">SNOMED V3</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2fcb69b5-67db-4bd7-8254-2a0c47612f08">SNOMED International</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_efc5d176-c7bb-4c33-b4d9-dd58564fcfe6">DOC: <link xl:href="http://www.snomed.org/">http://​www.snomed.org/</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_683ca2a1-14b7-42b0-8fa8-9f1b93bba5f4">SNOMED International Version 3 (see <xref linkend="sect_8.1" xrefstyle="select: label"/>)</para>
                        <note>
                            <para xml:id="para_8581b9b3-9b59-4f1a-9bb6-92919e96d9c2">This Coding Scheme is deprecated. The use of "SNOMED-RT style" Code Values is no longer authorized by SNOMED except for creation by legacy devices, legacy objects in archives, and receiving systems that need to understand them.</para>
                        </note>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_14221246-dd6c-443c-9254-93c519229893">SCT</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9cada316-7eaa-4bc6-9fe4-bac5852564f9">2.16.840.1.​113883.6.96</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_811eb298-14dd-4386-be95-e7be5284870e">SNOMED CT</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_109497a1-837e-43c8-a6d4-bef717d4827a">SNOMED International</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_80b2b2f1-4fce-4570-84c9-5c4598ada101">DOC: <link xl:href="http://www.snomed.org/">http://​www.snomed.org/</link>
                        </para>
                        <para xml:id="para_5aca5aee-e7df-41be-aefd-357d3e8f0623">FHIR: <link xl:href="http://snomed.info/sct">http://snomed.info/​sct</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6af3c4f1-a28f-407c-8398-78a86339f3f0">
                            <xref linkend="biblio_SNOMED"/>, using the CT Code Values</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_331a27e9-511e-4aa2-afa2-7ec9e085198f">SRT</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_958d40a2-2210-4d39-83c8-27416ffee045">2.16.840.1.​113883.6.96</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c1d22063-5b6a-456a-b1fa-0aaf661900e3">SNOMED CT</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_dfe41eb9-cdee-4387-b8c8-574d6ed59fd6">SNOMED International</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4fef2d0d-3e9a-494b-a303-95cea118c53c">DOC: <link xl:href="http://www.snomed.org/">http://​www.snomed.org/</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5980e9f5-eb65-4735-aae4-803ef0cdb96f">
                            <xref linkend="biblio_SNOMED"/>, using the "SNOMED-RT style" Code Values (see <xref linkend="sect_8.1" xrefstyle="select: label"/>)</para>
                        <note>
                            <orderedlist>
                                <listitem>
                                    <para xml:id="para_1f97db3e-52a8-4346-8731-3dbfe1ac40e9">HL7 uses "SNM" for the symbolic name.</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_4fea50b8-aa60-42ec-b4d5-081702500dbf">This Coding Scheme is deprecated. The use of "SNOMED-RT style" Code Values is no longer authorized by SNOMED except for creation by legacy devices, legacy objects in archives, and receiving systems that need to understand them.</para>
                                </listitem>
                            </orderedlist>
                        </note>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_01ce0631-db91-4b11-a0ab-a17dec9fa9a8">UBERON</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_63206896-b9a4-4633-bfd5-643d885325de">1.2.840.10008.​2.​16.​6</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f13b3889-79cc-43dd-a371-0f066b5f23a8">UBERON</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e0fe9f55-ccce-4f1b-922a-509479af8574"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d18f61e9-4e37-45f1-bf51-9d58813aa953">DOC: <link xl:href="http://uberon.org/">http://​uberon.org/</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e1d426be-e4f5-4e21-94f2-a57fc06531c4">The Uberon ID from the Uberon integrated cross-species ontology covering anatomical structures in animals.</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_b127a1e8-a339-42d6-9140-52256155b774">UCUM</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4c10ffdb-01f4-4cdc-b994-cdb729c978cc">2.16.840.1.​113883.6.8</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_640e85ab-571d-41b8-af6b-b2bb48e9b457">UCUM</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f357eaf7-9017-436e-9d63-9ff587b9f512">Regenstrief Institute</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f3d5e4a3-a14a-4582-bf47-f04506e13687">DOC: <link xl:href="http://unitsofmeasure.org/ucum.html">http://​unitsofmeasure.org/​ucum.html</link>
                        </para>
                        <para xml:id="para_94390590-276d-44cd-a165-db622fd1ef37">FHIR: <link xl:href="http://unitsofmeasure.org">http://​unitsofmeasure.org</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_04f074ac-982c-4db0-997c-151a8fd60267">
                            <xref linkend="biblio_UCUM"/> Unified Code for Units of Measure</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c3a217a2-5f91-43cb-9396-c4dc830651c0">UMLS</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e4dde7df-313d-4724-b227-9c042fea2560">2.16.840.1.​113883.6.86</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_dcd935cd-6fbb-44bb-b69a-5ae8dcae1fa3">UMLS</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0dece79e-0629-4e34-819a-fe98746f31f8">NLM</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7c1db3b2-5fed-46f7-ab55-56777584cf66">DOC: <link xl:href="http://www.nlm.nih.gov/research/umls/">http://​www.nlm.nih.gov/​research/​umls/</link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_33a3c53f-fe4d-49a4-b113-65dd2e976be5">UMLS codes as CUIs making up the values in a coding system</para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_4ce3c88f-53bf-4ab7-897b-e04a4288ddf0">UNS</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_eb5dae6d-dc1f-4a0d-8cbe-60cbde62f44e">1.2.840.10008.​2.​16.​17</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4f33f970-f23e-4318-bb16-2b443aaf888a">UNS</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_35695c2b-f947-4d9a-9ce9-73731d8c9b4f">SAE International</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6743d924-3bfe-41f0-8a46-0ec5b8c97f75"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8a800e0e-98da-4c1d-b7ab-0d0e8b00f87b">Unified numbering system (UNS) for metals and alloys <xref linkend="biblio_SAE-J1086_201210"/>
                        </para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_aa1a415a-c0ab-4801-ad2b-74b74f0079d7">UPC</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d324c526-e0e3-4e13-bd86-54b9a03095db">2.16.840.1.​113883.6.55</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_50083dff-1bf5-47c8-85c2-ba6a64c0c74a"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6152733a-16fd-432d-baaa-a7715e644fb0"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_86b7456f-c720-4c15-8664-1be597a1487b"/>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8f6e149c-c963-4b1c-b80d-6e49ee9263f5">Universal Product Code - Universal Code Council</para>
                    </td>
                </tr>
            </tbody>
        </table>
        <table frame="box" label="8-2" rules="all" xml:id="table_8-2">
            <caption>HL7v3 Coding Schemes</caption>
            <thead>
                <tr valign="top">
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_30f42a62-94b2-439f-83fd-51be1ff116d9">Coding Scheme Designator</para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_2abf40ce-26fa-4d4c-9fb6-103b8797463e">Coding Scheme UID</para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a871cb75-d470-47fd-bfd8-6ddf9d8a8fde">Description</para>
                    </th>
                </tr>
            </thead>
            <tbody>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f499480f-743c-4092-b8fd-f93f4082c82a">ActCode</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_67d78402-0fe9-44d8-892b-6a23b5db5b77">2.16.840.1.113883.5.4</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1"/>
                </tr>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6e2e6d3e-86dc-48ec-b7b6-ffefcc08698d">ActPriority</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_caeaad32-06d1-483b-9411-6ec9f575cf98">2.16.840.1.113883.5.7</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1"/>
                </tr>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_08277289-5b60-45db-b915-75ec605cbb2a">AdministrativeGender</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ee5ae8f6-f999-4f65-b492-756210621599">2.16.840.1.113883.5.1</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1"/>
                </tr>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a89c854d-65d1-469f-9a8f-edfb81c62b16">mediaType</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2d859441-19f0-43ae-9d36-e2f3d15b7caf">2.16.840.1.113883.5.79</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5f21e636-19dc-484b-bad8-7f895e03d419">
                            <link xl:href="http://www.ietf.org/rfc/rfc2046.txt">RFC2046</link>
                        </para>
                    </td>
                </tr>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3e4b9535-deaf-4fd8-b4e1-3714462b8946">NullFlavor</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0f4e67cf-e56b-4510-a4af-d7f73b7a73d0">2.16.840.1.113883.5.1008</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1"/>
                </tr>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bfcbd2e3-af14-492a-b849-2feef3607ea7">ObservationInterpretation</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3a819bf0-e0a6-4991-9337-fe0e45e5a497">2.16.840.1.113883.5.83</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1"/>
                </tr>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ab4131e3-f479-4b74-9f51-6d25fd3f6f8b">Confidentiality</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a032ddb3-2999-4efd-ac20-c77c02ed317c">2.16.840.1.113883.5.25</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1"/>
                </tr>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9908c4fc-bae0-4d68-af3e-a135732fe03a">ParticipationType</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5473bba5-b724-476b-be0b-63ab438214ef">2.16.840.1.113883.5.90</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1"/>
                </tr>
            </tbody>
        </table>
        <section label="8.1" status="2" xml:id="sect_8.1">
            <title>SNOMED CT</title>
            <para xml:id="para_1dd06a96-c0aa-48a0-a6fc-983137075753">SNOMED (the Systematized Nomenclature of Medicine) Clinical Terms (CT) is the preferred coding system within DICOM for anatomy, clinical findings, procedures, pharmaceutical/biologic products (including contrast agents), and other clinical terms.</para>
            <para xml:id="para_e7a4d291-64b7-4a51-960d-510224c1f431">SNOMED has had various versions, including SNOMED International (Version 3), which was issued in 1993 and revised through 1998, SNOMED Reference Terminology, the successor to SNOMED 3 that was published between 1999 and 2001, and SNOMED Clinical Terms, which has been the name since 2002. The Coding Scheme is fully backward-compatible across SNOMED 3, SNOMED-RT, and SNOMED CT. SNOMED CT introduced a solely numeric set of codes (ConceptID) in addition to the former alphanumeric codes (SnomedID), but all SNOMED terminology concepts have both a numeric and an alphanumeric code.</para>
            <para xml:id="para_5315275e-e297-49ba-aaec-ff45e85ca583">In previous releases of the DICOM Standard, the following Coding Scheme Designators were used for SNOMED codes in DICOM:</para>
            <itemizedlist>
                <listitem>
                    <para xml:id="para_6353285d-08a1-43bd-95d4-833dd827d183">"99SDM", denoting the provisional SNOMED DICOM Microglossary</para>
                </listitem>
                <listitem>
                    <para xml:id="para_61804987-e659-4cdf-a3d5-4639518f23c4">"SNM3", denoting SNOMED International (Version 3)</para>
                </listitem>
                <listitem>
                    <para xml:id="para_d8a8a9e4-e350-4803-84ad-e8e33a845c69">"SRT", originally denoting SNOMED-RT, but later used to identify SNOMED CT concepts using "SNOMED-RT style" alphanumeric Code Values</para>
                </listitem>
            </itemizedlist>
            <para xml:id="para_d8731612-2d84-4d7e-83c1-e9938a25e256">All uses of SNOMED CT coded terms in DICOM are now indicated by the Coding Scheme Designator "SCT", identifying them as SNOMED CT numeric Concept IDs as Code Values.</para>
            <para xml:id="para_7192aa44-28fd-494a-af81-f5a31fc1dd5c">When a Coding Scheme Designator of "99SDM", "SNM3" or "SRT" is encountered by a receiving system, the "SNOMED-RT style" alphanumeric Code Value needs to be mapped to the corresponding concept designated by the SNOMED CT Concept IDs assigned to the same concept.</para>
            <note>
                <para xml:id="para_229e3e38-a9b9-4de3-8dc4-0c9396ff133e">"SRT" as a Coding Scheme Designator was used only in the DICOM Standard. HL7v2 did not standardize a Coding Scheme Designator for SNOMED-RT.</para>
            </note>
            <para xml:id="para_78ae552f-5678-4603-a972-9ad31ec0672f">When interoperating with systems that use SNOMED CT codes, Application Entities may receive and are expected to send Code Sequences with a numeric ConceptID code. It is the responsibility of such Application Entities to convert any alphanumeric SnomedID with Coding Scheme Designator "SRT" used in old DICOM objects and services to the corresponding numeric ConceptID code.</para>
            <note>
                <orderedlist>
                    <listitem>
                        <para xml:id="para_70472ccd-1180-43ad-a51d-3c83c7e4ef2a">Some non-DICOM systems may use a Coding Scheme Designator of "SNOMED-CT" rather than "SCT" as is used in DICOM.</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_3da63667-8348-4524-88b7-ce09bc79e31b">The SNOMED organization's policy on the use of "antecedent versions", including the continued use of "SNOMED-RT style" alphanumeric Code Values is described at: <link xl:href="http://www.snomed.org/news-articles/timetable-for-the-withdrawal-of-legacy-snomed-codes">http://​www.snomed.org/​news-articles/​timetable-​for-​the-​withdrawal-​of-​legacy-​snomed-​codes</link>.</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_e4a99b2d-068f-42fd-a32d-58af72dfd1d0">Since the SNOMED organization no longer distributes a reference set that includes a mapping of "SNOMED-RT style" SNOMED IDs to SNOMED Concept IDs a complete mapping of those used in DICOM is provided in <xref linkend="chapter_O" xrefstyle="template:Annex %n"/> to allow implementers to process legacy objects from legacy devices and archives.</para>
                    </listitem>
                </orderedlist>
            </note>
            <section label="8.1.1" status="3" xml:id="sect_8.1.1">
                <title>Use of SNOMED Anatomic Concepts</title>
                <para xml:id="para_f3c6fc76-0433-45e7-b1b3-5bc08f55ca77">In general, DICOM uses the anatomic concepts with the term "structure", rather than with the term "entire". This is an important distinction in SNOMED. "Entire" is a child concept to "structure", has a more restricted meaning, and typically is used in conjunction with treatments (e.g., "excision of <emphasis role="italic">entire</emphasis> right kidney"). It is used in distinction to other sibling children of the parent concept that may identify parts of the parent anatomic feature. Since imaging typically targets both the anatomic feature and the area around it, or sometimes just part of the anatomic feature, DICOM usually uses "structure" concepts that are more inclusive than the "entire" concepts.</para>
            </section>
        </section>
        <section label="8.2" status="2" xml:id="sect_8.2">
            <title>ISO_OID</title>
            <para xml:id="para_627cef9d-16af-428c-8c37-e4bb111a68e9">
                <xref linkend="biblio_ISO8824-1"/> and <xref linkend="biblio_ISO9834-1"/> are the standards defined for the generation of object identifiers that are used as DICOM Unique Identifiers (see <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>), can also serve as a general mechanism for identifying organizations and objects defined by those organizations.</para>
            <para xml:id="para_efad7c58-da8d-4d03-8f4d-6fd398862e30">When the Coding Scheme Designator is ISO_OID, the Code Value shall be the numeric (dot delimited) form of a valid object identifier.</para>
            <para xml:id="para_947ff1f3-3ba7-4929-826d-1fbea2bee246">A repository of known existing object identifiers can be found at <link xl:href="http://www.oid-info.com/index.htm"/>. For example:</para>
            <itemizedlist>
                <listitem>
                    <para xml:id="para_fc0d7d42-c92d-4f2d-bce5-0ea3e730a974">the ISO 9834-1 assigned numeric object identifier for the country France, is "1.0.3166.2.2.1.250" (since ISO 3166 defines a means for maintaining country codes using object identifiers)</para>
                </listitem>
                <listitem>
                    <para xml:id="para_9397a115-dfb7-4835-b369-d6760429a77b">the object identifier for the RIPEMD-160 cryptographic hash function is "1.0.10118.3.0.49"</para>
                </listitem>
                <listitem>
                    <para xml:id="para_60a3c031-a810-424a-8f2f-2ceb95cd9253">the object identifier for the HL7 V2 table of codes for marital status is "2.16.840.1.113883.12.2"</para>
                </listitem>
            </itemizedlist>
            <para xml:id="para_b4928b64-885c-4e37-98a0-84b0a6c3f8dc">The re-use of object identifiers for existing concepts that do not have an alternative more appropriate Coding Scheme compatible with DICOM provides a mechanism to avoid defining new codes. For example, HL7 assigned object identifiers can be found at <link xl:href="http://www.hl7.org/oid/index.cfm"/>.</para>
            <para xml:id="para_eb7134b8-77cc-451d-a0ea-c63f742272e9">Though the intent of ISO_OID is to define organizational roots for the hierarchical assignment of object identifiers, and not specifically to identify organizations per se, the organizational root values can be construed as identifying the organization. For example, the DICOM Standards Organization itself can be identified by the value "1.2.840.10008". See also <xref linkend="sect_CID_5002" xrefstyle="select: labelnumber quotedtitle nopage"/>.</para>
        </section>
        <section label="8.3" status="2" xml:id="sect_8.3">
            <title>Retired Codes and Expected Behavior</title>
            <para xml:id="para_41f69a57-8a8c-443c-ab32-ebdd03c0318e">As this Standard and external Coding Schemes are maintained, the codes specified as Concept Names, Concept Values and in Conditions may change. The previous codes are considered Retired but implementations may continue to send them and receivers will be expected to be able to continue to recognize the Retired codes, including the Code Value and Coding Scheme Designator, even if the current Standard does not publish them.</para>
            <para xml:id="para_302538a2-59d8-4462-b679-85c6233519d6">A notable example is the change throughout the Standard from using "SNOMED-RT style" Code Values with a Coding Scheme Designator of "SRT", "SNM3" or "99SDM", to the use of SNOMED CT numeric Code Values with a Coding Scheme Designator of "SCT". A mapping of retired to new SNOMED codes is found in <xref linkend="chapter_O" xrefstyle="template:Annex %n"/>.</para>
        </section>
    </chapter>
    <chapter label="A" status="1" xml:id="chapter_A">
        <title>Structured Reporting Templates (Normative)</title>
        <para xml:id="para_1f5d4631-b1dd-44a0-abfb-560816acddc5">This Annex specifies the content of Standard Templates that may be used by DICOM SR IODs.</para>
        <section label="General Templates" status="2" xml:id="sect_GeneralTemplates">
            <title/>
            <section label="TID 300" status="3" xml:id="sect_TID_300">
                <title>Measurement</title>
                <para xml:id="para_77bd792c-bd9d-4e95-bb1e-f3846ddcda7f">This Template provides a general structure for a numeric measurement, together with evaluations of its normality and/or significance, and the inference source(s) for its value.</para>
                <table frame="box" label="TID 300" rules="all" xml:id="table_TID_300_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e78884e8-2fba-44cb-9543-7b13a3f3d74f">Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_87aed517-66ec-469b-848a-051450840c1d">Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e039a3ff-536a-4dca-bf00-b2d2fa99111c">$Measurement</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5457f0f-7d97-406d-aa13-d6be91f9b149">Coded term or Context Group for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6d70f93-7707-424a-9d79-3adcab4db4c0">$Units</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3badc168-22a5-4682-9b57-047d848b2f30">Measurement Unit</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6989484c-b1da-4d6a-bda3-d9a7d3583ca1">$ModType</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3979d08-a959-4113-aa01-a1840e7cb7d6">Modifier Name for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2220407e-bc25-4ccf-8b5d-0c95d1ddf80f">$ModValue</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b95a5982-014a-4d8f-a6a4-c5fb5c4a1f7c">Modifier Value for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8bcec88-37d6-4561-b828-e4d6ef3790fc">$Method</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e6519c4-97df-4e09-8762-4dd0dff32912">Value for Measurement Method</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d22fd402-fc81-4e8d-a0de-24ba7e68e491">$Derivation</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2abc1bf-a237-476b-adef-31ef6cada34e">Value for Measurement Derivation</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_336246da-7a84-428a-9e3e-412fdc412444">$TargetSite</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb6a2b99-857b-4083-a92f-36f182326bc7">Value(s) for Anatomic Location of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba99d0a4-00b4-48bc-8dad-1f0e99ffc186">$TargetSiteLaterality</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5c677f1-074f-4712-9423-9e1bcdaa7d40">Laterality Value for Anatomic Location of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0007a22-85ae-4827-a0f6-8e9bc75e16c6">$TargetSiteMod</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6bddb6e6-83a3-4167-b6f2-b5de271ed0bc">Modifier Value for Anatomic Location of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_380b1baf-5ace-4c43-b1ee-b425172579c8">$Equation</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2aed46c6-eac2-496c-882c-8953fb18a4fc">Coded term or Context Group for the equation or table from which the measurement was derived or computed</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_311f48b5-37c5-440e-8687-ff61aac2c7e2">$ImagePurpose</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0291ccff-9df5-4b97-a117-5f245e2d5d4d">Purpose of Reference for an image used as a source of the measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9972894f-aa6a-4168-83c4-0a734f412a88">$WavePurpose</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82836268-0d2c-4de6-823f-d567f7fc929e">Purpose of Reference for a waveform used as a source of the measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b3fff08-495a-43d7-8d44-8a00cb2be52b">$RefAuthority</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a69d6cd-aaed-4021-8451-c1abe771282d">Bibliographic reference or authority for statistical properties of a reference population</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_332e3c5f-951e-4610-96e9-d9e7281fcb11">$RangeAuthority</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5fef43e6-99a3-40cc-b156-c9054b6db484">Bibliographic reference or authority for the normal range of the measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c441e1b9-7b0b-4e20-b439-5fb3657634c0">$DerivationParameter</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c55737a4-e74a-495a-a5f0-a2ad15221e59">Coded term or Context Group for Concept Name of a derivation parameter</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e779ad8-08f2-45ac-9c31-29162f80ae8d">$DerivationParameterUnits</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_76ba2922-f81f-49d9-83b3-8ef04f67c183">Units of derivation parameter</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b8bceade-77cc-42b2-b249-19b0f692c2cb">$PrecoordinatedMeasurementMeaning</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7fe7783-e20b-4fad-8955-61c6ab56ac58">Coded value for the precoordinated concept name of measurement</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ab8fefe1-5cfb-4d98-bd8f-473072340e65">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ef0dbab2-a679-4f50-95d5-3f82597e6279">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_a17f8f3a-4c87-4b2e-8c92-218843e7986f">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 300" rules="all" xml:id="table_TID_300">
                    <caption>Measurement</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_72040574-5d06-4448-92d3-65d64029aec2"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6dc1a5bb-799d-4ce7-b116-2de6f00399b0">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ada3f541-03e1-4c32-aca3-f7f3d0de93e9">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_34201b00-0939-4acb-975d-63b09c385b07">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_104a2ec7-1391-48f6-b7dc-c5f94a8bb57a">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0699ebc9-be03-4846-a7b1-e8c504fd0ae9">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_40849f85-f55e-4dd9-bc80-7af5c0e2a872">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cd9bf78e-2ee9-47a9-8a55-5cf98072a759">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9856b597-aeef-4056-a98c-25b47f0aabcf">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e932889-0764-40b5-9f5e-ac3845d6f933">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b175a93-7c5c-48bc-a5e5-380db6283009"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ec6fe93-5cb0-4758-8adc-deef5678010b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5fe8320f-931e-4eec-91a8-f8d7ae6d7f00">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48165cbf-5ff1-4353-9c7b-c05569a0066b">$Measurement</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a6d1fd64-a1d1-4245-8dc5-88b325d3094c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5ab6a36e-54ef-41db-a7c7-de35a9843624">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5043dfda-6fa9-4044-b601-cb8254bff80b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0e7cc06-ed22-40d7-ae42-3e8831a76b76">UNITS = $Units</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c9ddc7f-1131-43ac-bf3e-5f37fbe8cada">1b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d761ed9-d521-4692-93fd-153962a3a482">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b52bc59-f6a8-41b2-a112-e7a9cd2a3184"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce0aaed8-6eac-4105-b402-77cb20cb3835">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97ec4bd0-a510-4e18-99a3-1cf8e3e59a5f">D<xref linkend="sect_TID_301" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a2156b4b-e385-4005-a0a7-f6b106acb816">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5594ff78-5e09-411f-af3b-0d9b96d33986">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de96a694-439d-4c18-a17d-38c5e3b5cf88"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_773e85e1-266b-423e-b5e7-7d796d538df7">$ModType = $ModType</para>
                                <para xml:id="para_ef59ec9e-7fb2-4dfd-84ea-ce2c07fe2707">$ModValue = $ModValue</para>
                                <para xml:id="para_ee685816-f0e1-40f0-8997-5dbc87a2114f">$Method = $Method</para>
                                <para xml:id="para_45cd008b-3ec6-41f8-819f-07ddea8bceaf">$Derivation = $Derivation</para>
                                <para xml:id="para_104742d5-7140-4573-bd39-c1781e4199b4">$TargetSite = $TargetSite</para>
                                <para xml:id="para_fe60f210-b7fb-4685-bd67-accaab642a1c">$TargetSiteLaterality = $TargetSiteLaterality</para>
                                <para xml:id="para_faa8af99-5f9e-4f74-9efd-5079e016957c">$TargetSiteMod = $TargetSiteMod</para>
                                <para xml:id="para_a1b7ab45-0a53-40f7-af0b-5f3cf446af49">$Equation = $Equation</para>
                                <para xml:id="para_480888d9-a68d-4604-9233-8d831e9193cf">$ImagePurpose = $ImagePurpose</para>
                                <para xml:id="para_0f86f32c-716a-43b5-b506-4a6543d3f657">$WavePurpose = $WavePurpose</para>
                                <para xml:id="para_31e8bbee-7a8c-4174-8a34-9350944b8268">$RefAuthority = $RefAuthority</para>
                                <para xml:id="para_9dbcb9bf-6896-4d3f-92a6-b0afb2c52c32">$RangeAuthority = $RangeAuthority</para>
                                <para xml:id="para_5d6e66f6-cb32-4c54-afdf-d7eedbe5e6b2">$DerivationParameter = $DerivationParameter</para>
                                <para xml:id="para_17b3f8bf-25cf-45d7-86ca-71bb557387bd">$DerivationParameterUnits = $DerivationParameterUnits</para>
                                <para xml:id="para_ff813349-c1ed-4e4f-bbf6-67b47e25b8fe">$PrecoordinatedMeasurementMeaning = $PrecoordinatedMeasurementMeaning</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 301" status="3" xml:id="sect_TID_301">
                <title>Measurement Content</title>
                <para xml:id="para_0d5121e8-f401-4c87-8368-bccea4a4baef">This Template provides a general structure for the content of a numeric measurement, together with evaluations of its normality and/or significance, and the inference source(s) for its value.</para>
                <table frame="box" label="TID 301" rules="all" xml:id="table_TID_301_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6d4c84e2-27de-4cf1-9408-425610ced9a0">Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_551166a8-81d6-4485-8041-39aa2306edff">Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b2af546-70ec-469f-897b-b7568e76f7cb">$ModType</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_afbc5e21-ab8a-473e-bfa5-e70af6cad48c">Modifier Name for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d859670-c400-49d7-b07f-552d90b58ac8">$ModValue</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39aad38f-e247-491c-902b-375661c445a3">Modifier Value for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0244e87-d0a9-48a1-83ea-92891418af7f">$Method</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_092b5bbd-a2a1-41c7-81ed-8162246d4b4b">Value for Measurement Method</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ce7487a-f3b8-47fd-bc81-dddd7c90e02d">$Derivation</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0c20530b-043d-4e1a-8638-9d94f9b8c71f">Value for Measurement Derivation</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b9944506-f8d2-4c27-99f5-b2f5ed791b71">$TargetSite</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b292232b-7c27-4f10-bf08-f2bc1a4fb155">Value(s) for Anatomic Location of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac0920d2-5c7b-4d96-ad50-2e72c9e2fda8">$TargetSiteLaterality</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6bee695-2a58-422a-bbb6-acb324cfd937">Laterality Value for Anatomic Location of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_89b6cf14-702a-4423-8b57-1554f54408c7">$TargetSiteMod</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8292bed-ede4-45e6-85ce-5a9c24bd879e">Modifier Value for Anatomic Location of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ee06ae6-86db-4efd-a4fd-5c7252fa6652">$Equation</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7ab31ca-8180-41cf-96af-4d3a71035442">Coded term or Context Group for the equation or table from which the measurement was derived or computed</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09ee2de1-1690-41c5-b8fb-dd54ddf40a32">$ImagePurpose</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98061e1c-bbf2-40eb-beb5-99a5dc61d136">Purpose of Reference for an image used as a source of the measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0c1a9412-4923-426c-819a-78780e0ea437">$WavePurpose</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b070dd2-2bdb-43dc-9a1d-49a2fb1aae07">Purpose of Reference for a waveform used as a source of the measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_45c3db5e-e54f-4c59-8cdd-e14f53545fb8">$RefAuthority</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_110bb578-f7fe-414b-8fb2-4a0d774a32e1">Bibliographic reference or authority for statistical properties of a reference population</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cbafbb6c-8df2-4a1b-9b9b-08de31ef9071">$PopulationIndex</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0851393d-0740-4f61-8887-6aa7666556ad">The index concept whose value is used to select the subset reference population that is relevant to calculating the statistical properties of the current measurement.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_68371d0d-4e1b-4c9d-8ef3-50206008c28c">$RangeAuthority</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a28c34f-d1ef-429a-aa41-b870f932b0ce">Bibliographic reference or authority for the normal range of the measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f37f79d7-eb49-4ffb-ba11-6d80b75d0794">$DerivationParameter</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ceff6a6-df11-417e-8526-02593f4ad15f">Coded term or Context Group for Concept Name of a derivation parameter</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b4bf6d1-8b2d-4311-91d7-e1bfafde6b19">$DerivationParameterUnits</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0caf1bf8-37e0-43f2-8b66-0bfc6c699a97">Units of derivation parameter</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_817b241e-30be-4270-b8c2-c9bb2acf219f">$PrecoordinatedMeasurementMeaning</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e37353f-ee94-455d-be27-adb568c1288a">Coded value for the precoordinated concept name of measurement</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_a474dfa0-4a5e-4482-ae59-a70c52a926ad">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_22901ffa-47d6-4353-81d4-37c222a0790b">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f5d69579-cfa3-4db1-be5c-d63fdfce4d43">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 301" rules="all" xml:id="table_TID_301">
                    <caption>Measurement Content</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8cac0727-59c1-4329-b242-8a29f1198b00"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ec986d85-fb44-4a0a-9fe8-626ba7509f70">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_78c61fc4-ea3c-4dea-8673-e9c4b28bc8f6">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5fceff71-8beb-47f8-8c76-41dc02d800c0">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1a92fd00-30f2-457a-a624-834d7825808d">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_30ce2258-7e3f-4c8f-9a16-85a380dbc866">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d7508033-cc48-4c78-9f99-aeb3e1956cd3">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e90db86e-daa2-4d5c-939d-9dacb3650c6e">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ebc8b514-1102-4ac3-a122-c46dd966dac8">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c515a4c2-545c-43c4-8e41-ade857100b6a">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c94a32ec-4213-4104-9bab-c3f6db880f93"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_689822ca-4490-4ddc-ab4b-fa40eaaf2ee0">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7fdc1a0e-c8a0-46d7-96d9-6c3d8ee2531c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b0eebe5-a3b6-4489-8519-995ab0fb2387">$ModType</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_72a99565-a981-43c6-b839-2ea70017869b">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9f7c2de4-d8f4-4da7-b290-b85c8d6374a9">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f35b74d0-e5b2-43a6-aa54-fe99d4fb9621"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9202f3c-77aa-4877-8002-f52a780921c3">$ModValue</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1a38665-2780-47a2-8288-b2ac487c6998">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b94e2514-7250-42fa-9b08-6b893ad01093"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30586168-f816-4111-8cdc-f11f95a81d0b">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f382fab9-034b-41e1-aa6f-a7185be151b9">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b72d8b6-ed15-4a08-9b5b-289774f7cf5c">EV <link xl:href="http://snomed.info/id/370129005" xl:show="new">(370129005, SCT, "Measurement Method")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c07f112c-405c-4d23-be39-6a581360dcae">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_838f090d-85d8-4634-8fd7-e2fa6f6039b1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6560d8a-8154-45bf-94d2-37153ca9099f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2db623f9-eb56-4064-970f-909c99c2a31f">$Method</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e5425fb-b11e-4ce9-8481-bf4a3747daf4">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d6b34bf6-827a-40ba-8b4b-be7b2de154d3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04f58196-f7fe-45be-b29e-ae83c4d92fdc">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5542c40a-7059-4932-b225-434e716ad737">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b90b1fb-e270-4b78-800b-1d187de4e1d5">EV <link linkend="DCM_121401" xrefstyle="select: nopage">(121401, DCM, "Derivation")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ca8df5bb-1433-4349-8f74-72b58b00b6d9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cda9ee73-45c3-402d-8c97-9b7488003a2b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dabc7969-5f11-4e95-90a1-c456bcbdb6a0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c43c691-50c8-4531-a525-c7ee0892e657">$Derivation</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_842a90c7-9b2c-4e1b-9d86-07032d12440c">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5831500-d717-4acd-b9f0-e1830aa51c47"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5bcc1fd5-adc6-40f2-9d60-ac63e06e3ae6">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52d994f1-7970-430c-98c6-d6f793b4fc94">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5eb269ab-ac5b-4d94-8a57-65f11a3120c3">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_620460a5-326b-427c-bbf4-b91e1aadb9f0">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a5fb68de-67b6-48ad-a052-670d176b1a63">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_721786ea-c21c-4c3a-9548-550c54e19cd9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ecabefa-537a-4f14-8b77-f5d7e7abc868">$TargetSite</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d351ac50-bc5b-4990-95e0-590c7c311491">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ea5b580-7476-4ccd-bf8d-1c4aae332342">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_53959fa5-9bba-4765-80fd-5b7a9880ddc8">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e500ea97-1971-4b1e-b316-09423b1e2458">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55011eae-faab-453d-89c5-60f2b8e7a403">EV <link xl:href="http://snomed.info/id/272741003" xl:show="new">(272741003, SCT, "Laterality")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0961a671-0b3c-4ded-978a-5830e6c0880e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_27501979-c2eb-4352-a929-85fa10dc148c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d067a1e3-0284-4cfc-beac-2c127ea50637"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ea85369-73ab-4414-bc58-9e5098ac7d70">$TargetSiteLaterality</para>
                                <para xml:id="para_760eb9f5-5cb5-4415-930b-9df9a996ac58">Defaults to D<xref linkend="sect_CID_244" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c84a9a9d-404b-45f3-95e6-a0788c85a1e4">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9fb178ea-cdaa-40bc-be05-5206fc09fbf1">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69f456db-3070-400c-bc29-ee9e3e11d64f">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c49d44f8-3d49-40da-a2f4-70949603f29c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae97e081-9e86-4c97-90d2-d44ff283b411">DT <link xl:href="http://snomed.info/id/106233006" xl:show="new">(106233006, SCT, "Topographical modifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2ce576e6-dbff-44ee-a636-8edcd0056567">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d790e090-8302-446a-a659-1c295bfc889d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4031f3f1-b19e-47da-b68d-974b820fddb1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_588bdde1-6eb6-4381-9df6-bebc5afefb83">$TargetSiteMod</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55fe4e86-cca8-4940-a540-f4671dc0299f">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3023b9dd-13cd-4226-8581-b965fcf2707b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fcd20d74-1731-4c10-a82b-f5f833fd15e2">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43b37530-680e-4a91-b528-d23f15ae3074">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48f871f5-996a-4c76-9e96-4770562ac907">D<xref linkend="sect_TID_310" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5c29e082-0dcf-4fa2-addb-92519d41714e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_690ef0da-0abe-4c43-909d-1da7dbcdf06c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd9608ef-d2bf-4299-ba69-b5085bd20e57"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1724ebe0-9179-4a20-a841-10c211c21038">$RefAuthority = $RefAuthority</para>
                                <para xml:id="para_9da30933-2d4e-4bf7-88e8-bc697a00342b">$PopulationIndex = $PopulationIndex</para>
                                <para xml:id="para_458c2786-5228-4d78-87ec-e3afc106df26">$RangeAuthority = $RangeAuthority</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43381e20-6ef0-4650-9d9e-da46ec75ba79">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_daee4ae1-1990-4e4b-8bbb-6b005058e282"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f26c7f9-c49a-4ca2-8858-5c435b7ba3a3">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d9d6bef-6713-417b-bf49-7b47aa74b693">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb72713f-a9f4-4dd1-ae98-b38b33de4880">$DerivationParameter</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a1c094ed-6a6b-4b41-8f22-1d353f747243">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8de34b01-9262-4b03-9511-a5aa39fa4794">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4775203-ee1a-4b1f-a1cd-4c54d7fe8dab">XOR Row 10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bfcb79da-82ef-4927-9a4f-a996dd7c6757">UNITS = $DerivationParameterUnits</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd9992da-41ce-4e0d-92fe-86318d362bd7">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48f7e292-83e6-4fd0-8fe9-5ad09f47f479"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84f7a34d-f097-4ab4-9090-c41cc80d520d">R-INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_baf0060c-0a8a-4ef3-bc44-0d8b2b551943">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_625ca83b-7a41-49f7-85e3-3438077fb640">$DerivationParameter</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9250282c-225f-47fe-af9d-c8792a8deb2f">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1c647934-4d63-4c9a-b7dc-4d86f52c1df5">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59c20b99-32ea-4634-91d5-dbe8957d0757">XOR Row 9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7fd8f155-8c00-4238-9d8d-5871d87443bc">UNITS = $DerivationParameterUnits</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10e094a4-53db-45d0-92fe-b6b6d42d0a13">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5766072c-5bd3-4569-acf4-6daeb654f73f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85e15b2f-722e-41e3-9a73-84710fd3cbaf">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03dfdd98-b520-4631-86c9-fb0be07aa719">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0dec0e69-4ca9-46b7-8078-b1d9eeea7c9e">D<xref linkend="sect_TID_315" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1d2b6f4b-1493-4e02-aeac-6d3e9879447d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aaff5d2c-9786-4aed-a9d9-6e6bcedbb7f9">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d8041e0-b30d-4e10-81ad-3b929b364a05">XOR Row 12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70492950-ae80-4731-b562-31b8b1b33f47">$Equation = $Equation</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d2fdd423-32ea-4648-b480-9d09020900f9">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67bae056-7e0e-4030-ad90-6efa9cfe1d59"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d30b8d9-4cc4-420b-aeff-12193d252f89">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6fb0a06f-4888-4155-883e-e2e2a9d1133e">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8dcdc31f-b3d8-479f-b25f-67ef7ecf2501">D<xref linkend="sect_CID_228" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5b8bd265-dec6-4c3a-a698-b195890ca5e8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a76c7edf-04cc-4626-9af1-9fcc2f783890">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5c175e6-a7af-4f17-ac9b-54f386e648ea">XOR Row 11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a623f5b-403f-4444-a751-c3f205c9f538"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_770d16b5-21b5-4887-96bd-6aeaf6afd2c8">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10c8009f-cdf8-481e-a705-02fa7087fc41"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3918619-21e2-4ed1-b694-45f56b4953aa"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_161efed5-07f7-4bc4-9c2f-baffaed7e8f1">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf78b3b7-4ed9-47bf-88a9-18efa573270c">D<xref linkend="sect_TID_320" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e1a45d45-0533-4a14-8fba-e85f2a151d8f">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_72e4002f-993f-410a-99d7-d699a37f8340">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eaaa3c9a-40ef-4fa0-82e2-39369442ba24"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22d6c3ff-aaca-45d7-b0a6-d0109f903293">$Purpose = $ImagePurpose</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f1f348a-5796-4a87-9ba3-f2889749259b">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_451e74d0-aac0-48d2-99fe-d88c8f19c95e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_efe5adcc-e9c9-4812-badf-d6d44e61aa4b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c40f07c9-ca79-4b2f-8065-7325242d588b">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e79da970-e41b-4528-b581-450ab8af39d1">D<xref linkend="sect_TID_321" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c274ef43-d146-4065-9802-fbe6c4f48ca2">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3e6d8f0a-39ac-4c87-972c-e242109f5fe1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ea7f370-a961-4816-867e-e6d3d41763d2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_594b4882-e970-47db-9edb-c64c94f3421c">$Purpose = $WavePurpose</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7aa30b0-48fa-47d3-b01f-526dbfd309fe">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de9abf82-2580-4ed2-b827-66fd38bd0bb8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_248194c6-08ea-4081-a987-67ee3386cfdd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5aca031-f439-4c73-93e7-04a9349d9f57">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03e11b2f-4ca7-4965-a63f-d424952bfc53">D<xref linkend="sect_TID_1000" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_41f7b608-3448-4e63-af78-f8b995bdc738">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0dcd4a6b-302a-4a27-8895-a530a154ee07">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52ef5229-812f-4efb-ad81-46d5454f112c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5a0cce9-8350-4e8f-80ed-f5d55206196b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a041534-7087-4287-9602-af9928c73c30">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_56a190fb-cd34-40de-8d6d-4eec35958b13"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d897d7e7-1ced-4087-b3ad-7137de920360">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1d9895b-c478-4112-8afc-816cb4b3edd1">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a836245-f544-4e0f-ba7f-14532c3196d7">EV <link linkend="DCM_121050" xrefstyle="select: nopage">(121050, DCM, "Equivalent Meaning of Concept Name")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_92ace882-b4c5-4d3c-9240-e5779a2238f9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2562d454-f655-49a8-8fab-182e76a9f03a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35dfcf1c-1a3c-4ddc-b49c-1bfbc9d51050"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1a89c74-4147-43f6-ad3d-ea013444ce4a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39645f16-a661-4fff-b808-43d249bf3c2a">16b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2cc16679-38c0-44d9-a8e1-87e062f6d2a4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e27ef2f-0ecb-4c1a-9aaa-89f5a4612b1a">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38aab58b-3b47-4c7a-9aa1-ee33a18b816b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bdab23b5-7e4b-425b-b560-3dfb544ded96">EV <link linkend="DCM_121050" xrefstyle="select: nopage">(121050, DCM, "Equivalent Meaning of Concept Name")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fa96914e-c7a6-45a4-aa63-7cf006665673">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e0ac6770-d490-40fe-b9d0-e5de0668ece3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bcb0b6a1-000d-4c79-88c0-5abbfc33cccb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73c835c9-470b-4395-be30-6cef3b373317">$PrecoordinatedMeasurementMeaning</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26c23e39-a9c1-4701-98a6-106282354629">17</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc5a3807-a0c7-4d54-8052-d82df186390f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8cac7bd7-9c79-4ce1-a84f-242d236c7ef0">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d5d1c26-bcdb-47f2-ba7b-63bfc34170ef">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f59c744d-2c77-475f-875c-a9dd0dd3e259">D<xref linkend="sect_TID_4108" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c39a5a76-3780-4adc-9520-3a00ee799552">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_35798212-6c86-4213-bba5-94e3d4b03a09">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b38af8cb-5096-4c9b-a325-9a5b55dc1a3a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd31b1f0-0ee9-4a19-8749-73a389d7cd88"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_673b4f2b-1fd4-42c3-be28-2691c914334a">18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f93ce24f-3cce-44b5-9f68-d29922a19e46"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ec8b82d-6fae-4ff4-b67a-531effecdc45">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d6706747-38ef-49db-a6a8-2751edfb08d9">COMPOSITE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f828a919-5902-43ad-b84c-7be92deb8eeb">EV <link linkend="DCM_126100" xrefstyle="select: nopage">(126100, DCM, "Real World Value Map used for measurement")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a8a2b73a-12e7-4d5a-8325-a62f25249248">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8dbd6f45-fb6e-4182-b964-a80797c29990">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_202d1931-abc7-450b-bfc3-5abc88d95a7f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9054b3b9-cd7b-4eb5-9a63-a9b44b2200a7">SOP Class UID shall be Real World Value Mapping Storage ("1.2.840.10008.5.1.4.1.1.67")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_34625822-8896-42ed-b521-0531c03174c9">19</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_110b18ac-27da-4e25-b8d3-5e3fb7964492"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_edce7dc5-cb16-4585-9226-e1e35e81564b">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a690c6ad-8e82-4829-bc89-20e99aec550b">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_183a95cc-a257-4743-9765-b8b2e889ae16">D<xref linkend="sect_TID_4019" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e0678672-8b48-4285-b9f3-796f47903fcf">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c8517cbc-dbf3-44b5-bc57-8782ac895159">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5005f9fc-75ba-42bf-a3e3-74b3161efaf5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be8acca7-0043-4ec7-901f-46c966708429"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_47520af6-e69e-4a7f-8aa4-7474eea66c8b">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_effc493f-84f6-437c-84af-31ff7bf9c06e">Rows 2, 3, 4, 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_33fc3488-12f8-4222-ad96-24b55739f20d">The HAS CONCEPT MOD items allow the explicit definition of terms for post-coordination of the measurement concept name. Additional post-coordinated modifier terms may be included in a SOP Instance based on this Template, in accordance with section 6.2.4, or as defined by Templates that invoke this Template and explicitly define additional post-coordinated modifiers (e.g., TID 5203).</para>
                            </td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1">
                                <para xml:id="para_fcb505ed-af0f-4b3c-a679-ff3afdfa0d41">Row 5</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_eb15fbee-f367-4d74-9be2-986aab9259f2">Finding site may be multiple when a region of interest spans multiple anatomical locations and there is not a single pre-coordinated code describing the combination of locations. E.g., when a maligant, inflammatory or traumatic process spans actual or defined anatomical boundaries. There is no requirement that the multiple locations be contiguous.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_77cb86d4-242d-4dc3-aae4-96cae1a4324e">Rows 9, 10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a50d2d4d-b98c-4f68-8e87-61e2fad1c693">The INFERRED FROM items allow the specification (by-value or by-reference) of numeric values that were used in the derivation of the numeric measurement of Row 1. The nature of the inference is not explicitly conveyed; it may be implicit in the Concept Names of the measurements. Inference by-reference is valid only in SOP Classes that permit the INFERRED FROM relationship by-reference.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8e7caaf-dde9-4374-92ac-7ac590731ee5">Row 13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67cdfc1f-94ef-46f1-8788-5b3a076eae6e">Multiple SCOORD Content Items may be necessary to describe the source of the measurement. E.g., the measurement of an angle between two non-intersecting line segments requires two separate POLYLINE SCOORD Content Items with the concept name of <link linkend="DCM_121223" xrefstyle="select: nopage">(121223, DCM, "Arm of angle")</link> conveyed in $Purpose.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59a58317-74ca-4d14-8a57-3d1f319d9129">Rows 13, 14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d082de9f-2615-4bb0-b7c4-cd96bc0e503a">
                                    <link xl:href="http://snomed.info/id/260753009" xl:show="new">(260753009, SCT, "Source")</link> may be specified for $ImagePurpose or $WavePurpose as a generic Concept Name when there is a desire to avoid having an anonymous (unnamed) Content Item.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8478bcd-4ae8-41d3-99e5-3029ac1c531d">Rows 16, 16b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8adf7435-8928-478a-a82f-a4eabcc8d850">Equivalent Meaning of Concept Name allows the creating application to specify the preferred composed concept name representing the measurement and the associated post-coordinated concept modifiers. The concept modifiers may include those specified in this Template, in a Template that invokes this Template, or at the option of the creating application in accordance with <xref linkend="sect_6.2.4" xrefstyle="select: label"/>. This composed concept name may be rendered by a display application. It may be supplied as text or coded concept or both.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_228b5e1b-b7be-434e-a77a-56dd1279b471">Row 18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7b31254-30fb-4b6d-9c23-60fc0150cf6e">Row 18 is a reference to an RWV that describes how measurements were made in units that differ from the stored pixel values in the images referenced in Row 13. E.g., for a PET SUVbw measurement, the mapping from activity/concentration units in the referenced image that was used (and which may be reused for measurements in the future) may be encoded in a referenced RWV instance. This reference overrides any reference in an including Template (such as for a Measurement Group).</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 310" status="3" xml:id="sect_TID_310">
                <title>Measurement Properties</title>
                <para xml:id="para_b202a14b-10bd-4c3a-bec3-c10413e1452d">This Template provides the properties of a numeric measurement, including evaluations of its normality and/or significance, its relationship to a reference population, and an indication of its selection from a set of measurements.</para>
                <table frame="box" label="TID 310" rules="all" xml:id="table_TID_310_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4f652606-dba1-4f91-8f25-6b7734120821">Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3bf810a6-6268-4de8-99e4-2f5608ecce46">Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae37982b-6a97-4797-9a5f-69b1961545b6">$RefAuthority</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13602846-dd9c-4d2b-bcc7-666813351394">Bibliographic reference or authority for statistical properties of a reference population</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36bde19c-00f7-42d8-b169-4f29390efdec">$PopulationIndex</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c1d06e8-94b7-4851-b53d-1503bc3d4731">The index concept whose value is used to select the subset reference population that is relevant to calculating the statistical properties of the current measurement.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c9707ffa-6dcd-4983-80f1-a47acc24c1d0">$RangeAuthority</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da7cc524-185d-4c70-ba8d-771cbd53e7b4">Bibliographic reference or authority for the normal range of the measurement</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_650b0c54-6579-49ef-b88c-d30a13dba0e0">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4fce6de9-e5cc-44b6-af4c-1d944dd9d472">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f5ff0b6b-5889-4358-a62b-bdf41dd63910">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 310" rules="all" xml:id="table_TID_310">
                    <caption>Measurement Properties</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_23335704-113c-4447-846f-22edeb8a6c26"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_47971d8a-28a0-4dba-b342-7ce1feb7b0bd">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_756dd63b-bde2-4482-808b-d7c3b9e9af39">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3dce1869-ab1d-4ab9-aa13-7faf332a0c5b">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dcba70e0-7129-4a42-b78d-aa9b5f9871db">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ab7585df-a953-4c60-aaa2-8ca62d57a6e9">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5e5c1058-d662-47df-a5e7-1e341c2976f2">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aecfc93d-a9b7-4735-88f3-7585e782ebe4">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b8b6af6d-6706-417b-916e-f07e26d1f5a2">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ccad4d0-df38-44b1-8ca9-e20365aedeb1">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65a9f2fc-3ef5-49c5-95b9-927e4f13d763"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4dac77b6-6ad2-46da-94a5-99dbc42986c5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d49a28e1-1630-426e-bd4c-4e703e7ebb36">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d03fdd9-fb1a-4b4c-9100-9fef8b0d7c5e">EV <link linkend="DCM_121402" xrefstyle="select: nopage">(121402, DCM, "Normality")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c58f0f20-1afe-4ef2-8835-ce731f1aa45e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1abdeaf5-4a75-40d0-bf09-954b833c740a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_76a0ba33-fc5d-4e03-96f3-5a959f4e4f29"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ec93760-7cea-4da1-9ba0-567047563b2c">D<xref linkend="sect_CID_222" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b429636a-f7b1-434d-9e9b-b042ef1c2336">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98d869a4-c3fd-41c5-bea1-80ef78dc2b59"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_347f958c-06b6-4f1d-a957-3bba62397468"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b49a6f4-1a18-4b3d-8ab3-3a433124a2b6">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7839607-5f75-46dc-9273-3c2705274a80">D<xref linkend="sect_TID_311" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0d6e2925-e4b6-4c4a-aeb1-1e1739e61742">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_82223977-1e06-4433-a99c-69f22ff29084">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d239fdb1-86d2-49a8-aea5-9f89c5b39700"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa657165-6119-459d-9415-52735f28d556">$RefAuthority = $RefAuthority</para>
                                <para xml:id="para_bec4b1a1-d681-48ef-bf96-0b99cb62376b">PopulationIndex = $PopulationIndex</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7392baff-8ccf-461a-851c-f934e7a9a680">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2523f9a-fc11-4791-81a9-c8f2d16b5919"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ec22452-e6a7-4843-8b6d-a6d34bd6b703"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c8d9412-3f01-4d53-bac8-1eec16cab9bd">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_538b2317-fc40-460c-a920-a881397aaee9">D<xref linkend="sect_TID_312" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6a6b8496-2a37-4fee-9d8f-eecaddb3019b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8de59858-657d-4bee-a131-f3efd056e062">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7bd994f9-cf59-4e75-b73a-fb227d6c41d7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b6e608e-051b-46f6-a298-a85b82d6308b">$RangeAuthority = $RangeAuthority</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f18e592-74a3-439d-8b93-d7715b17b1e5">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05cfc679-dca7-47a9-b7c6-479e0db0d04c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2148eee7-9537-4a4e-91af-32d4376f1200"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7af77b04-bb16-471d-ab96-b03b611af612">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e78df9d-f1f1-4a63-be33-bb179d44985c">EV <link linkend="DCM_121403" xrefstyle="select: nopage">(121403, DCM, "Level of Significance")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5fcc90a8-59ba-4599-8015-c2dd4c96be54">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_83e7a9ad-043f-4e06-94cf-25826a51f82c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb182b2e-157a-4990-9323-3ed0dc80cbb9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a24e6ef-dc1b-4438-887e-9b0a0597b858">D<xref linkend="sect_CID_220" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6138fed8-8b75-4389-b2dc-9021ef93017a">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_18905db1-290e-4dec-acad-66f8d331cf64"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_95111ab9-147f-4d79-b9d6-d3540af77646"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69e9b6cc-9b2a-4cf3-8183-4a3341024624">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3da04f6-5b0f-4ea2-890d-455618300548">D<xref linkend="sect_CID_225" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_282a4935-d59c-4935-9554-fef28aef6acd">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b0caaeaa-8329-4e8d-8729-0b57fc2ee420">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0e411bd-34e7-4c29-ae4a-a14f94314bdb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2562aa66-34a2-480d-b8ef-41fb54e7886c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d47ddc40-017f-4777-bdf3-8d25e90e34ae">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e72fe33b-ffaa-4941-854c-186ec9afea64"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b361f3d-a797-456f-8ece-151662c84c83"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b1f1108-aaba-4930-a6f8-4bfc873acfb1">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f95db2dd-f21a-4778-9ea7-3df78d5b79e6">EV <link linkend="DCM_121404" xrefstyle="select: nopage">(121404, DCM, "Selection Status")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0e2b633a-39f0-4a9e-b863-6bf5a85c7971">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc3f937a-c7ab-467f-8698-1cda8b48d3de">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_deaf6350-62b2-43be-9eab-1172028028f4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10f7ba09-149e-4f29-91c0-4b08edab21ec">D<xref linkend="sect_CID_224" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 311" status="3" xml:id="sect_TID_311">
                <title>Measurement Statistical Properties</title>
                <para xml:id="para_08cefca4-cbf4-4615-b336-a1c6e379621b">This Template provides the statistical properties of a reference population for a numeric measurement, and/or the position of a measurement in such a reference population.</para>
                <table frame="box" label="TID 311" rules="all" xml:id="table_TID_311_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6d6241a7-1121-47db-83bb-b9f0db23c18b">Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_07ae9224-c6cc-473c-95a9-69269d4973ba">Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a19c26e-6b6b-4a43-a093-1c2a3cac4ae7">$RefAuthority</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30b40629-9c2c-47fb-a396-6b3e3d4659a1">Bibliographic reference or authority for statistical properties of a reference population</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2e05720-dfda-4824-b571-98834a983c92">$PopulationIndex</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61995c4c-eb1c-4bf4-b4b8-dadaaf949c93">The index concept whose value is used to select the subset reference population that is relevant to calculating the statistical properties of the current measurement.</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_78fb6a43-0f2d-4bcf-901d-25d4b751f576">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_844b5dff-11f2-4183-ae86-b7b697461e5e">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4ea6c2ea-71d2-4d40-a094-88be524b2af8">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 311" rules="all" xml:id="table_TID_311">
                    <caption>Measurement Statistical Properties</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_30ae2b9e-a520-4736-8960-a61f6c2b34f3"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5187b283-4f7c-4f74-bac0-ef13dae944a4">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e5f9c4c0-5c92-4920-9770-d1c21748bee5">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_483dd26a-e851-4cbd-90c5-f498ff407ae1">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ffdecec9-e2ee-4d4f-a29a-49945ceb5c07">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eadce0ba-300c-43f9-b17a-500a371317be">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f04f3565-2837-4f92-92b8-cafcccd4a682">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0dbb22d8-a529-4362-b4e3-ee4ed6e58117">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf06c9b7-24a9-4afa-90a0-2a10b5e5b936">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d0808ae-fc21-4a50-8aed-8588d2f31eda">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c90a2067-ef4e-46a0-86bc-dfaed01d57ac"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8cd8e4b4-50df-45db-b46e-4bc15e3de7dc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b864fde9-129f-4b5c-b215-51387d7981df">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0c17cbc8-7b27-4965-83d5-499dc3919b77">D<xref linkend="sect_CID_221" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_07003f73-9c04-48a9-8fe1-ddf703491bef">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_49bf1df2-b090-4250-8567-56a9aa1a5ee5">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3a5b76f-1ea4-446a-9e02-0c813b44c847"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5059c44c-0d8a-4601-9117-3455db9a8222"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b12205c6-17ab-4af7-af6a-4e3c2d47f656">1a</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46514898-627e-4c67-85fb-ea5ce3ef9ed8">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_841cef75-1751-4ffe-bc0b-671601833dfe">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3812e83d-2e4b-42b7-998e-1eb62c8daade">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_efe0ff53-10bc-4815-bd7c-8c1b6eacb9fa">EV <link linkend="DCM_121418" xrefstyle="select: nopage">(121418, DCM, "Population Index")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2e6ee0f5-8182-4097-8313-5697d9490bfd">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fd434c2d-ed5d-4690-8429-2f1975ac902e">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73a4e946-ff7f-4c1d-9a93-fd7914e04ee3">IF Row 1 Concept Name = <link linkend="DCM_121416" xrefstyle="select: nopage">(121416, DCM, "Z-Score of measurement")</link>
</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eafdf93e-b7c9-46d4-85e8-33c1e6781ae4">$PopulationIndex</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8cf9a7e9-0ca1-49ae-9c1d-755fa47efa56">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b442ecc2-2256-460e-beb9-8a77bb90427b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0ca7596-a2ac-4ec5-963f-d62885457a69"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb7ebb57-ae03-4add-9155-336cf3da6961">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27743dd8-0bf6-4d80-a03f-e62e3a6409e5">EV <link linkend="DCM_121405" xrefstyle="select: nopage">(121405, DCM, "Population description")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c1595b9b-b611-4566-bf13-dce1d09ed161">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f3e87b64-7d2e-4d01-bf73-752050d887f8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c138e6e-dad7-4089-b73c-45991adb5918"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08f5cb44-20fa-40f5-bd40-2774d7f579cf"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86157c95-88c6-4f08-a9c0-65f73f06bbc1">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a81247e3-0593-4bf4-924e-3fa021c67984"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f654640-463b-4e31-a46a-01f95a762cbb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc98dc80-b63f-4619-b9b0-94234ecf083f">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_221a9459-8047-4985-9f3d-8b137e9b7092">EV <link linkend="DCM_121406" xrefstyle="select: nopage">(121406, DCM, "Reference Authority")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e31fd7c8-7497-40e0-8f5f-4a7fcd358397">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2bfde8fb-db35-445d-a596-d6422a3434f7">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f05f24b6-115e-4436-9f6d-ff60d1682746">XOR Row 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7fd6c07f-0a60-48e5-bdd8-ccfbdf0205bd"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_acf704b8-6ef5-4c1b-be44-2fc6a8a8cf6d">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_53083d16-1e22-4d1a-9b44-fcf1228ba628"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_000b3da2-a3f6-4571-8d49-ac169592fc69"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_116525ff-ef6a-4821-8813-a2127301d436">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9af8e5e8-c0a9-4978-a83e-a17d2d1920e3">EV <link linkend="DCM_121406" xrefstyle="select: nopage">(121406, DCM, "Reference Authority")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bbb0b8ad-e4d6-4fe4-9c98-f489190fb9bf">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4e5648b6-e15c-4ced-a5c8-045e88dd65e8">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35a796d4-6f68-4daa-8428-6ab56d4b1cc4">XOR Row 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae7dee52-d29a-4d0a-be1a-245f95c629d2">$RefAuthority</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 312" status="3" xml:id="sect_TID_312">
                <title>Normal Range Properties</title>
                <para xml:id="para_5dc75d35-ee83-4f00-9ec3-0e89896dc061">This Template provides the normal range of values for a numeric measurement.</para>
                <table frame="box" label="TID 312" rules="all" xml:id="table_TID_312_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a95d47a-bc67-4e65-ba11-0ac892d83a57">Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ae08a6bd-9440-4a61-8f90-6de738717bf9">Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_507c381a-8c06-475d-9d4e-6bf1a9ad0e21">$RangeAuthority</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bda1123d-4942-4b36-a5ac-6a5577a47884">Bibliographic reference or authority for the normal range of the measurement</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_0a896839-1e57-4337-ae23-d649055fbef7">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_c2eaa586-eb69-4649-93e3-a04bd3521f96">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_7792dfa3-e5c0-4856-8853-962892b9a95a">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 312" rules="all" xml:id="table_TID_312">
                    <caption>Normal Range Properties</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5647cdfb-45f1-476d-957e-a13d6b3758a5"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_64a5543e-2e50-44b1-99f0-03c9572d8d39">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b33ea8fb-0b69-437d-87ae-7f9704b5e568">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_68ae0170-86f8-4168-98a1-4753e8289a29">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_87092c39-c0c4-4e87-b8af-e989f7f11526">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_930f8451-3482-4bc5-acd1-c833e830bf00">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d362e581-80c9-4c5f-b60f-16eaafb86132">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_34358da7-1eed-400b-b2c1-dda36f4dd734">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_205db279-f5a4-4013-9bb1-58ee7d6f3d0c">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88ca89c2-78b8-47e5-b7b0-0fc61e15d3b4">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ada8604e-d9be-47de-adc1-2b312c737176"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4c04af4-388b-46f2-a786-33ba7f376302"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6549103-513f-4155-8161-b069619318e1">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_89bbc32b-acdb-4911-99f4-7d38fe867342">D<xref linkend="sect_CID_223" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e1bf4be4-20dd-48ee-b99d-b504644a865d">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_036262e8-f7a1-4a99-acb2-a8c509334173">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bbfe8631-726b-492b-82dd-63a406c54116"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d4279e5e-06c9-4ecc-b3bf-8ea5e854f0cb"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bfcf74d8-3fcb-4e3c-a2a3-9accf2d8b4c9">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_347f412a-fc6b-48e4-9ddd-3f6159a8cc6e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bbd64782-bb1d-44a7-980c-c7b39c736014"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce837e16-2bfd-4bd6-a7bb-e3d7760d188d">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36e9957b-a62f-4439-b804-36bd0143f624">EV <link linkend="DCM_121407" xrefstyle="select: nopage">(121407, DCM, "Normal Range description")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6babd482-cfd0-467b-8ced-c68affa12e07">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_584bd1a3-ffc2-46bc-a312-dce17088b899">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37f2b111-e5c2-4059-8bc6-7374d2483ebf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fdd30f37-76a9-4f08-9468-cb9f90aedfc1"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_335f8ac3-1f7a-485e-ba02-9123a724d8f4">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b78eb72-b082-4691-8324-19106b3e3463"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c224ff2-ff93-4701-87ea-09224223a4d9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4eb37cef-ae93-497a-aa6e-33fb48703fb8">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7e683f8-84c1-4af9-8026-3b6aacaca4fe">EV <link linkend="DCM_121408" xrefstyle="select: nopage">(121408, DCM, "Normal Range Authority")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bf50b6e7-b22f-42a0-8bc7-0e8a55dca167">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3cc1ae5c-0e18-4883-8e40-1a47d3b3451c">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b85cfc03-f96f-4391-bce1-e7a16b78210c">XOR Row 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c64d59a-2185-4bc8-a764-a919f93fe92f"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce9c9129-ba1f-44b5-ad99-58123fcc0129">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ceaa764-b1ad-4ae1-b1c8-ece1a71efa64"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d611692-4659-4b99-b8b0-434ceb0435bb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35ff93f4-d15a-4acd-8d65-cc6c258cfcb1">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bdfb061d-84f6-481e-8047-20513af1f173">EV <link linkend="DCM_121408" xrefstyle="select: nopage">(121408, DCM, "Normal Range Authority")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dc3105df-e957-4519-9179-1f54fb20841b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dc2e2a96-7181-42a0-b4d9-a4199c0005ec">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0c0bf678-47ac-4007-a0b1-44a27124caa1">XOR Row 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa997531-917d-4051-b097-a24386dcd9dd">$RangeAuthority</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 314" status="3" xml:id="sect_TID_314">
                <title>Ratio</title>
                <para xml:id="para_c3656e59-135b-43a0-b8f0-db5e3b5bd099">This Template allows for encoding of numeric ratios with explicit numerator and denominator.
                    The Container Concept Name (with modifiers) is equivalent to the numeric measurement Concept Name of <xref linkend="sect_TID_300" xrefstyle="select: labelnumber"/>, and uses the same parameter names.</para>
                <note>
                    <para xml:id="para_323819d1-d7ba-49b8-ad44-057649deca35">Compare to FHIR Ratio DataType <link xl:href="http://www.hl7.org/fhir/datatypes.html#Ratio"/>
</para>
                </note>
                <table frame="box" label="TID 314" rules="all" xml:id="table_TID_314_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="left" colspan="1" rowspan="1">
                                <para xml:id="para_823ae60d-94d0-41da-b145-47dff098041a">Parameter Name</para>
                            </th>
                            <th align="left" colspan="1" rowspan="1">
                                <para xml:id="para_89b34ca9-7381-43b5-9e0b-411d9ebc487a">
                                    <emphasis role="bold">Parameter Usage</emphasis>
                                </para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31aa38c2-1d57-4f10-90e2-ef4fa43c4001">$Measurement</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eaee7f80-12a9-4a24-bc88-b60c5765f879">Coded term or Context Group for Concept Name ofratio</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b1588ca-aba5-49eb-b863-de1bddf221df">$ModType</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9916624e-256b-4600-853b-578c66c8611f">Modifier Name for Concept Name of ratio</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6625cf08-c1ad-4120-bfa0-67b309451850">$ModValue</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_76f1cbed-05b0-4f44-a3b9-680d78150922">Modifier Value for Concept Name of ratio</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a1ef6dfa-48e5-4f3b-add4-17fb2b52c163">$NumUnits</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_012668ff-c212-4ce9-b618-6bfa49ede81d">Numerator units of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f900b33a-00af-4570-8ea8-cdf46fe41cf9">$DenomUnits</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b14cbc66-70c5-4d19-9940-3c08e183dd20">Denominator units of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab8a587c-8f7e-4f99-945a-b3c8661bd424">$RefAuthority</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed1beb17-921d-44d0-a158-bf28613ec245">Bibliographic reference or authority for statistical properties of a reference population</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0b2ade5-ab48-4ced-ba46-f4819245be5e">$RangeAuthority</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef8f8d57-7cb8-44b3-b4f1-eb7959571976">Bibliographic reference or authority for the normal range of the measurement</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_abd6b3ce-ac0a-4c39-9ba4-3ff7070ea728">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_1f792e11-3bac-4eca-a4d3-f48894af7276">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_e08d3fac-8721-4118-ac9d-73566254b1a5">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 314" rules="all" xml:id="table_TID_314">
                    <caption>Ratio</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1"/>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_79b97a12-080a-4d37-ba99-889141cc8fa9">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2c27c952-ff61-4a88-be7a-99677098d8fd">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_371335a6-f978-4971-85b7-24e744406c81">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2564c221-0bea-45b3-96f7-1313e5a40743">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1a18d5ba-151c-4451-b4c4-c21888210db8">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dbab1e01-357d-41fe-a5c8-7dac8c62bd3a">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dcbb5796-4370-42b0-9598-376d1d16c8a8">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8a852ccd-62e2-4679-b319-a8fd5e70f006">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84a1a89e-5fd4-4b70-8a95-1701e2d84bad">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_418034ca-2efb-4ff0-b7bf-bd9e06830c9a">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f45f2143-eb94-40e4-997e-164f92cb9a61">$Measurement</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f366060a-5be1-423e-bdd7-fe89d693291c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cac7e2f1-1d6b-47fd-bb17-82bf271698a1">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_19c06b05-e99e-46af-8a88-5bded8c83f9e">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_667a3f56-90c4-4a08-b080-d163b3810050">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d88233e-5bcb-4514-8a9f-138277626c26">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91a47508-aa34-4f8e-944b-a7f2a4781b9c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ab3efc1-9062-4c93-a7cf-e6082e34690f">$ModType</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b9f8241c-98e0-4b7a-839e-033c262842a3">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a983bee-3807-4104-bb09-decc8bc1f7e8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3936f98c-94dd-4a4a-b960-82185fae105d">$ModValue</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a76c869-70e1-466b-b75e-dfdde36d00b4">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4503a093-70d1-452c-a5a7-a2526b8269d2">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6561719-5ea3-4246-9433-a0f0894960ca">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38af949c-61af-4c4d-8424-7996536d8cf3">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98aac1df-95a9-4880-b912-47a9ee1e15ed">
<link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C80490" xl:show="new">(C80490, NCIt, "Numerator")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_902ce004-6cc4-4422-ac69-ec4c47e75006">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4562b60e-7928-4a1e-8808-e0d03738af2a">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_275e4b1f-104f-499b-8e9e-53d2dba3bbb4">UNITS = $NumUnits</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9fef578e-783b-4d2d-baca-4bffa4ab6682">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0508910e-ff6c-4684-90b9-fa79a2161689">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe7e273b-21b3-4130-8d41-0bf6d11de780">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_332a5972-5749-4b1c-9d52-c2fac546381f">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3a8a9d5-c700-416e-8147-ade6e6a63b76">
<link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C80489" xl:show="new">(C80489, NCIt, "Denominator")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3f1391a7-7a6c-4053-898c-d17f4b055668">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ec80ce8a-bddb-498a-8580-de54fe1b49ee">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c356d62-4f0c-470b-b434-6650a5f4143a">UNITS = $DenomUnits</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e71c2cbf-3fad-4c91-b083-b30a86efd0bc">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73d6da3f-2408-4c6f-876e-871bc5e66ddf">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ace32fce-c8eb-48c4-a4e6-d3aa5804c7e2">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82d14e08-7f7a-4d85-951a-ff2075797700">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a82412fc-c7ea-4ca0-b95f-aea9ae09f49c">D<xref linkend="sect_TID_310" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_efc244d8-acb9-4099-9eee-490dfdcc534c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ffc899ba-7441-4a58-b48a-5a6f1cb42e70">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7a2885df-e2f8-4290-aed3-44833e50575a">$RefAuthority = $RefAuthority</para>
                                <para xml:id="para_6efcd94f-a6cb-4ce9-9948-433513269e6f">$RangeAuthority = $RangeAuthority</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f804580a-4685-4c22-96b0-b977c8aad6eb">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d099949-f776-4a24-8aa9-186275a6fd77">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d39bab76-2f47-4a7f-a73f-3c88371f9035">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f282ebd-48a8-45ab-949e-83c242d4d26b">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_407c757b-e295-41fb-8ea8-6394ebdc43cb">D<xref linkend="sect_TID_4108" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ecf0228f-62a1-4e0d-931b-7a601d533e41">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_46aa7327-1499-4ed8-b744-b9f05f84c4b7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 315" status="3" xml:id="sect_TID_315">
                <title>Equation or Table</title>
                <table frame="box" label="TID 315" rules="all" xml:id="table_TID_315_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_022b1127-2eaa-4338-87da-370ce03dbe39">Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c3899c9b-496b-4989-a38a-2bfb6609250b">Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00cec662-0515-46ea-9727-64fc60ccbc90">$Equation</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb6ec831-287a-411a-84d9-890a7fc73acf">Coded term or Context Group for the equation or table from which a measurement was derived or computed</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_c2d93ebb-4d44-4f36-827c-ee2003dfd620">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4d3b03bb-dfb7-4ff1-bb12-abbffbb50c5d">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_d66cf6b1-1530-4158-97f1-1c2c1f54f60d">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 315" rules="all" xml:id="table_TID_315">
                    <caption>Equation or Table</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5b4d11e5-0a52-4d57-9936-dc79c759ff45"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_94bf9d54-3a4e-4727-807d-22f0a304d282">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b99d200a-5cae-4c20-928e-432ae7feb6c9">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ee98f045-23f2-4c52-97a2-310d03674c88">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc8e89aa-c2f6-40a6-a9be-049b341eb2a0">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7202f73d-ff89-4431-8e41-8cec9ad1767c">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2b5de4da-ee22-4023-964a-3dc5fa6ecdc2">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ce8955bb-3aac-4474-9ca9-daa0a1eef2b2">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c5072ae0-9408-4857-90b5-4df3e9e4dd68">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05b5df5e-b693-4672-8972-68c53a0f7205">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13aaa9e4-a064-422b-bf90-ea93800ed88e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb94d513-9cb5-443d-b4ce-e9356a924571"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c7f4c86-7311-454b-a9e8-da8b9f1d944b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ead7bbb5-40d4-492b-a69a-70918818ac4d">D<xref linkend="sect_CID_228" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0a738de9-4eca-4eb1-a51f-ad2528939953">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a969ba15-8341-480d-9c0a-494d7e1f4df3">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79cd1407-c3c7-4c32-8e68-eefe815a425f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6350f044-da92-4295-b06d-90d154a1b923">$Equation</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab22dd8e-1b4e-4251-b02f-966c6ab3d2e4">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cfbb25c6-8496-487e-9467-e56c2d2889a9">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4cd06b5f-90d3-4cbb-beb2-dd38d6f36c4d">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96c89d4f-49f4-4e86-9333-77f7b37b3808">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0961dd7f-6d32-41da-b2d5-5a700993b4ee"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_297e1242-af8b-4e10-97cd-2af7a9c07dd7">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7904d5d2-05fe-43b9-a3a3-5eb31566c864">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5eff3afb-0411-48cc-9da1-5e9b1de09d3c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bba6b0b6-1a07-4567-af73-0cb5fe0ef936"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c165c8b3-24d2-4096-8bbf-14f8e04f8d9e">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c4ec19b-9f82-4483-8605-c14fc7d7ac50">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4fd60428-6226-4d94-99b9-17d5d691b1b3">R-HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0bdcd2bd-4def-4612-930d-4d5c3333b3be">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4570099-0851-4f27-95e7-85f4b4a7900e"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9f6f5095-5920-4d05-a45d-7349ad334dff">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_062b197b-cc13-4a31-8ffa-026e7534ed6f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_940dd101-ee7e-4bcd-97a4-04b7424593a9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eabced23-b962-4bd0-85e0-a7bec4e50247"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_97645d4b-b531-4f06-bf61-dc015d3b4786">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6ff6860-49cc-43b0-b2eb-b180629cdfa3">Row 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4b30823-1179-4151-90f9-ae2fae8da270">The HAS PROPERTIES allows the specification of the numeric values used as input to the equation or table identified in Row 1.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79a49f12-4c17-4f6f-bab8-fe071597650f">Row 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a19ca85b-97e8-4830-a4bb-9da818cd0d8c">The HAS PROPERTIES allows the specification by-reference of the numeric values used as input to the equation or table. This row is valid only in SOP Classes that permit the HAS PROPERTIES relationship by-reference.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
                <note>
                    <para xml:id="para_286190c5-0329-4b76-a125-15b932628e70">For example, if Row 1 identifies a specific Body Surface Area equation, Rows 2 and 3 can be used to convey (by-value or by-reference) the Patient Height and Patient Weight numeric measurements used in the BSA computation.</para>
                </note>
            </section>
            <section label="TID 320" status="3" xml:id="sect_TID_320">
                <title>Image or Spatial Coordinates</title>
                <para xml:id="para_84f7c83b-02ef-4a5a-bf94-7bc4b9bcaaf0">This Template provides a general structure for inference from an image, either as a whole, or with specific 2D or 3D spatial coordinates, as a single included Template in the invoking Template. If allowed by the IOD, the Image Content Item may be included by-reference.</para>
                <table frame="box" label="TID 320" rules="all" xml:id="table_TID_320_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ebd96938-c3b9-4a1f-bbfc-d6e2140302b5">Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_89248ed1-fd4f-41c5-acae-258078e91ccc">Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_147b3698-eb79-4c4b-8091-57a5e86c3a50">$Purpose</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fbcddfc1-e820-4df5-991a-1f9270ee8482">Purpose of Reference for an image used as a source of the measurement</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_86ba5141-3f51-4d9e-b2af-73b0fc447051">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_3ec4c3d0-5579-480e-a05a-7c3ba392fe76">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_58e35304-977c-4c46-85cc-07a591b317fa">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 320" rules="all" xml:id="table_TID_320">
                    <caption>Image or Spatial Coordinates</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e5f8bc8f-75e5-4644-88e4-d925e2427406"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_333bd5e2-7629-4c4e-8037-3629257e3f2e">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f0beaed-eea4-481c-97da-68077db0157e">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_23fb0cc2-5f00-4082-adb0-57061734c895">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_89a0aa3e-f8b7-4ee5-9ddc-2351e9934939">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0dd1ad58-9adc-45d9-90e5-51d90b0aa683">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_756a86ea-2029-4ade-94ce-ff5c3d0fd533">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f39253c8-c566-4914-a066-96fbba0740a3">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_30c31544-a1e3-4254-8a17-2ef2b1fbbdd7">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_caf417ca-507f-4096-9d79-46df005553ff">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86376ae4-4426-4900-8fd9-b726051dc125"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63be4664-2031-443e-a119-84603e9d7aba">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ef550a4-77b3-4c8f-902e-afa764d03179">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1eca1136-5edc-4a15-a64a-190637f5ec0c">$Purpose</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ef1ab5cb-27b8-4b45-a527-4b2893bc4c6b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4f86962b-c32a-4be7-b103-327b495de1e4">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ddab8be-9d01-42e9-9dd1-09394ea1079e">XOR Rows 2, 3, 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2dd3f6c-4280-41f3-a386-65063f83351e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c44ea90-1048-444d-aa82-c74e1b481099">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26a28c7d-a02b-4085-9f99-fa24a514ea67"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e837ba1-3f6f-4aa1-855e-97fcfed4867f">R-INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1463cc45-fd45-4e9d-ad38-3f46fcf5d6a4">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ea17b4f-cdde-4b81-b79d-39af735de2a6"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d15871e7-06e0-49b6-848c-b216c80fded6">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ec65b768-3373-414d-b5a8-fecb38956134">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2edb8274-04da-4083-9e6e-1428f981d3c0">XOR Rows 1, 3, 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b70a03e-1daa-4c62-a28e-432e2f6a65cd"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ed28e47-c8db-491f-a314-44175372a0d3">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0664dea2-011d-4824-8030-26dcc6596bf2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75cea5a6-f615-4a68-90fb-ee0209ca10e9">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e621a2a-9387-423f-8aca-638a0b75932a">SCOORD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7138e34-b551-41ab-bc33-39d38e2947be">$Purpose</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc4b8124-3eb7-49ea-9fba-17a9d5cc5353">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ee9fa0a-d9ba-4797-906d-20d63e15a305">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c724e5e2-ad3c-4530-b978-ed19b07eef7e">XOR Rows 1, 2, 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b057dd2-b9d2-43ff-839f-e8d0651c27fe"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a78fd17-12e5-4947-92a8-5cb96644e39b">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_256ec7f8-d499-4428-96da-d81d8ad92208">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2032108f-4677-4719-9386-f196e010fd11">SELECTED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f547296-0472-4e1b-8c4e-45a92b35645c">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04bd368c-1689-4d64-8f6b-e62e041c27d7"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f5c6efa4-6319-4435-8466-bddda077f19a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_74b90508-968e-43b5-be17-b965e856342c">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aeb0ea69-01eb-48ae-a7e1-922b71b704ae">XOR Row 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7eac4ea7-f3ac-4b03-9004-a336241011ef"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf6ebe1b-356a-4df1-a064-5d562238bc2f">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e84ddfe6-14b4-4e06-b13f-acf34fe65c8e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b9973c22-8f4a-4db0-8895-61d1ee409963">R-SELECTED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d7adb4a-0c19-4c64-a114-b722207bebca">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75a56d6b-fb2c-40ce-9517-1f9f6d92b639"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ff3ff7a4-cf80-486c-9d56-d47767d9fa89">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_801a4820-fdd0-445a-b0c3-775a5467993f">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_76afe243-3c68-4f0b-b8a8-6547a0654090">XOR Row 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4717b023-e2aa-40d4-9c67-dfc3bef1d5ce"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ab19ac5-bd94-4f99-8020-3b5b3b7c25a4">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eea9ad10-9dbb-45ee-b32d-15854ab01af6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_feddcbcf-a895-4369-953d-9aeace9b5b9c">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96cf5c8b-f179-44f9-b81d-881460585dae">SCOORD3D</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e678416-7fbc-4912-ac72-d9b962d94d81">$Purpose</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f2d3d25b-659a-4bd4-ac95-541a87fc58ed">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5d6d6f8b-1323-41f0-b69a-fe413137c823">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d250747-91fb-4b02-bc4a-dd0293f2caf4">XOR Rows 1, 2, 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06c58002-c3a3-4203-9275-5fe9e2f4c1c6"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_2f5d2285-7299-4b02-8d12-81178ad14f55">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8814b6ec-8935-4159-8b40-45fc9fd25913">Rows 1, 2, 3, 4, 5, 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8637b7b8-4df3-4d5b-836a-ce3651cae269">
                                    <link xl:href="http://snomed.info/id/260753009" xl:show="new">(260753009, SCT, "Source")</link> may be be used as a generic Concept Name when there is a desire to avoid having an anonymous (unnamed) Content Item.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 321" status="3" xml:id="sect_TID_321">
                <title>Waveform or Temporal Coordinates</title>
                <para xml:id="para_98cb1c78-a607-408b-8ba2-74268c89c094">This Template provides a general structure for referencing a waveform, either as a whole, or with specific temporal coordinates, as a single included Template in the invoking Template. If allowed by the IOD, the Waveform Content Item may be included by-reference.</para>
                <table frame="box" label="TID 321" rules="all" xml:id="table_TID_321_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4fc0d7fd-f6a0-463a-9bad-73bd297ac300">Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_820425ea-3512-4005-9918-bbed89f262ab">Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10d8a235-4a96-4a49-90e4-71880bd67fb7">$Purpose</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f008d5b8-10dd-4450-8954-0679e9d9f08b">Purpose of Reference for a waveform used as a source of the measurement</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_3464e857-d217-46aa-99de-624dfb5dffee">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f2fe488f-f3b7-451b-9361-bf88b7727ac7">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_3fcc5832-4ad2-4960-94b8-76f4feaf9509">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 321" rules="all" xml:id="table_TID_321">
                    <caption>Waveform or Temporal Coordinates</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85f4b0de-69cb-4cb0-9c9c-155e74ea90d6"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_af143f7b-6b65-4e8a-bbca-baa091de04e2">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cb6cbf98-62b5-4ddc-9de8-2bb24291877c">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_34f344b4-b416-4ee7-9e2b-fa32af4f3100">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0b68f4ee-3fab-4bdb-8907-31853975ca28">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_98820300-76da-47af-b72f-5c6ca5d39839">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ec58d21-4ef3-4ca0-bf73-fdd41a4447fe">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bf809437-ccff-42fa-93e0-d8abc2eaa3b8">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_29671141-ca40-4b18-b2f4-ba95f4bdca59">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac0fb94a-d0d3-4b06-a702-ec652580983e">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79a39b69-2cdd-45a2-9858-8c2091b62dff"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e574468-bed4-411f-89a3-2f84bc8ecc21">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_113cd5c6-d27b-4a80-99d1-5f56955264d1">WAVEFORM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54c693e7-f74c-4ea2-886b-6512f9c67682">$Purpose</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fad8d8e8-d639-424d-9ab2-c7c449e6be61">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_91f647af-84bc-43c9-a726-582a5e05df3b">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f28f708-776d-441a-adaa-e532bf362155">XOR Rows 2, 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b3ebcbc-3b55-4f6a-bd65-5812056c6ce6"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e710cf00-3d41-4f50-81f6-9433f72a2db0">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3aea2952-194c-465f-ae05-024e08294ccf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab65a1d4-f32c-4621-b2bf-0dec6bf3a846">R-INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9193e03-0479-4fbd-a72e-2e68a02efdae">WAVEFORM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa418de8-4034-453e-ac3c-c5991f1a71e3"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fd93aff8-4f31-4abb-9315-64841bd4dacc">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a0546d70-6aaa-41aa-92ee-185f417eac53">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1e4ba49-996d-452c-8d2a-933c041c0404">XOR Rows 1, 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7c06286-aec2-4874-9096-aa2664263f4f"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3cb25d62-8a73-47dc-9ab7-209ffec5d131">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cba8f261-3fb6-45d8-b1d4-4270cab50d0a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8dc67cd0-ee9d-4fce-b179-382dc7bdcbd7">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_322f393d-e282-4305-be08-0d4ebe3d3e50">TCOORD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6cb7a734-3037-4ca0-8e88-92e15db7f3a9">$Purpose</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3443dc49-4ea3-4848-bdcf-03458016c14f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fa4074d7-e00c-4606-a911-fdd2dbbfa92b">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e37aa2a-faff-41d8-b6b6-3b6bd10f8f21">XOR Rows 1, 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c6cc009f-4981-44c5-9730-ddc19c02b769"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_200e2050-6259-44eb-90d3-2a21d5b88ad1">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6c8a13c-faf8-4b7f-af55-d40fc54cf502">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38dcec74-ff32-4a7a-a844-22c46ab2d430">SELECTED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e0cca61-800e-4c39-af6d-7a1aee3244a4">WAVEFORM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36aecfbb-cc13-49a7-aabb-57fc44ad04fa"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d56198ef-b279-42aa-b626-b129c11fb45c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_90f5cff2-b254-4330-a19b-aebc18095c6c">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_66062a81-5a8a-41e9-a6a7-b22760f1ea1b">XOR Row 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0eb82f78-a498-4ce4-b8c2-968b8e042c5f"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2aea49b-df60-4553-a506-366a223977df">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d0851e6-252d-4d09-a96a-acd8a3d132bd">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3dcc0886-e92c-42d5-8e41-00c5c2183604">R-SELECTED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17be6630-8d0e-484e-80ce-0c145b0ee59f">WAVEFORM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e251192-45a9-4cba-9d2d-ffc676e80793"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ea1e62d9-82dc-4f31-9b05-534193cc66bf">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_512c2801-d3e6-495b-aa14-a2ed7358b536">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_608fb84a-c7bb-4c3e-aa0e-b409a3b0c3e1">XOR Row 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_811532c8-53f3-41a0-9268-473b8b248b2f"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_95555501-c4b9-49d3-ae94-dd1159cd72da">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ffc1f2bb-9101-4119-a5bf-0cc494a07428">Rows 1, 2, 3, 4, 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0dbf0d4c-24e1-41d5-876f-32fedeff49fd">
                                    <link xl:href="http://snomed.info/id/260753009" xl:show="new">(260753009, SCT, "Source")</link> may be be used as a generic Concept Name when there is a desire to avoid having an anonymous (unnamed) Content Item.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 350" status="3" xml:id="sect_TID_350">
                <title>References to Supporting Evidence</title>
                <para xml:id="para_b803fcd6-bf97-43ec-a62d-360f8d3c3aad">This Template provides references to supporting evidence in the form of DICOM composite objects. This includes references to images, spatial coordinates on images, and other composite objects, such as Structured Reports.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_0d801890-8f1e-489f-8187-25009cd39f5f">
                                <emphasis role="bold">Non-Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ba086606-a308-4264-81e4-0b0144db1fa1">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_94eb0abf-3611-4cc5-bd27-4c89cf7311ee">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 350" rules="all" xml:id="table_TID_350">
                    <caption>References to Supporting Evidence</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d9b4659d-cf88-40fa-83a2-58f8c9c8a149"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d8ea73b8-aefd-4030-9b4c-7c4aca240c39">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_623bb89d-5d28-42d5-8b2c-f5d09e70089c">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_991a9eb0-f48b-45bb-9d1b-6190524f48c1">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fdbe35ef-6294-4365-8270-c213b081f8f5">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_271ef412-6d3e-4c61-bda7-19102c54fc6a">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dd1744f6-79c9-42a0-8306-af7d8736f31d">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8ace9d86-16f6-409b-b46b-6aa124bd1a57">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0e07076d-9563-4a87-b127-d167d5face04">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9479391-8b76-42ce-8cd3-692bd4869507">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae284d3f-a87b-4bbd-b224-a3cf1b8d05ec"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c514e3a-744c-49a5-ab37-4813c924d8b9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_351b9e22-6276-4040-8323-c2e3f0529295">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d15600e-6ed3-4c27-9eb5-0b2da8611e84">B<xref linkend="sect_CID_7003" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4e07a901-8867-4e10-8e72-403211f15e5e">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a79eb8e7-0261-4800-9c3e-748b581c599a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce3a2baf-027d-48dc-a6c6-a7f21249f950"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9bcbd3a1-a6fc-4b78-b738-d0852ac5029d"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c6c717e-a983-472d-a3c0-9d31bb6cf938">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_44dec6a1-229d-40ff-bfb3-09a5e9d05bba"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72a3e409-fc17-4af7-85e3-ce221c5d8bbb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e41b737-49a1-455e-b165-0544fed70dc6">SCOORD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a49d9c3-c180-4b43-8a7c-8b1405d8198e">B<xref linkend="sect_CID_7003" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_725cc100-3565-4a61-b588-3aa1b23b0acb">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_51f9bc88-2e52-4b70-a2e5-4c3833989676">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6e21384-c623-4ef0-af93-242c31260fcb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aad4e719-4ab1-430a-8092-3219ba6da86f"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e0c1a144-96ee-4887-bbd9-fcbeb2059e93">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b50162b-69f4-4d88-8bda-7a7e460b0b07">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73e3f669-f393-42c1-ac6e-ca67f035f1b3">SELECTED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02ef1757-3d0a-4de8-8b54-ae64b1a7425a">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc563271-9399-4f05-b801-df99beac2cd9"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_324d7ce5-b1ed-4765-8a20-141b6cad0a8a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aee251a8-c508-466a-86cb-77802e58694d">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa5ec3ed-7e65-4a76-942b-5f6eb64b6452"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03f4cde3-c373-4c14-8677-02000ad6a731"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3cf2fed0-3870-462b-a916-f29bd9a40692">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5be6f081-7555-4ade-bac1-7d4f0cae7009"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd9061b2-45b8-4a74-93d6-265ee1a95b42"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a1e0efc-f87b-43c8-8526-11945e09d975">COMPOSITE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_94fe3124-d341-450d-a8de-9b422f58a845">DT <link linkend="DCM_122073" xrefstyle="select: nopage">(122073, DCM, "Current procedure evidence")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e4a9a26f-e2f8-411c-bd3c-65e35d6d2e4a">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_122e3bb2-a81d-4493-b353-2b7eeda66c05">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59371505-4784-47f2-9979-993f05ca71b5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff55afac-56cf-44d1-a809-85ffc7ea3b15"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_afbb3fd1-8fb2-43ee-ba6b-f9d76e6e5696">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99c02624-cd07-4c01-8986-f487875339d1">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be754560-13c6-4cb7-bb4a-faa843c4a32a">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f6768f9-4151-4b76-bdd4-94cd977dab97">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03c04be4-ee53-4751-9612-2e8237f4dade">EV <link linkend="DCM_121144" xrefstyle="select: nopage">(121144, DCM, "Document Title")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d6d30f6d-3fbe-490e-88e9-d714ca027e47">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_572b20df-44d9-4695-9563-4e1c7908303a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_378d81bb-1624-4ee0-abfa-0f7d462a527c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8607b88-2fbd-46fd-9404-12fe0088cc65"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 351" status="3" xml:id="sect_TID_351">
                <title>Previous Reports</title>
                <para xml:id="para_27b4c9ae-81d0-488b-a536-e1a346731e83">This general Template provides a means to reference previous Structured Report SOP Instances.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f555136a-7c6a-4b45-829e-87bc0caf51a4">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_e384396a-dfde-44ce-a655-75eacc970f92">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_efa97b1f-d53d-4bd1-99ec-1058f1accc4d">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 351" rules="all" xml:id="table_TID_351">
                    <caption>Previous Reports</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c12051d0-624b-4dfb-8767-8fe2b2d86393"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_77770599-4f49-42f6-ae14-11b0a1b93a75">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b3e47b00-4c0f-4786-9f99-4af1f8dcb490">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4398c68d-8f4d-4aa3-8a1f-f48b960b7aec">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6653cb0e-f0aa-4292-be23-039583a3d147">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7f901a0-27d7-4c42-9fea-e1bfa927013b">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aaa6a886-2e2f-42a7-a7dd-64c1a34bb65d">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_02dea0ed-82b3-43f2-af6c-45ba4a804ad5">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ddca66d7-290f-4d0d-9405-8c55acbfbc40">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2516efd-705f-4b24-b7cf-07ab67af7ec6">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_07a80b99-e9b0-4f5f-b5cf-e8d59e4d4971"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93b70ad5-8cae-4d05-baf6-a633138d5bd1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea6dab72-70d0-4203-a8fe-489a580da752">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f9b23bd-4eaf-4620-a467-04cd4496be8a">EV <link linkend="DCM_111549" xrefstyle="select: nopage">(111549, DCM, "Previous Reports")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f63ace9d-e7a9-48a5-b2bf-2e25cade868f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4cd49988-e87f-4354-b41f-f833905d9091">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7dee9a1-2f6c-444b-b270-7c4c4a04d85b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea6bf7d2-ba6b-4d2d-bbfb-57807cc6a841"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e6992b2-26f1-4042-b185-da4c6209ab79">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_66c9a26a-baa7-44cb-9571-14220d03ae7d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5fdf2ab7-6051-4307-a4b7-cbc70b92b668">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7b9e286-e1f4-44b4-989a-4b7ed78ecea5">COMPOSITE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0de2d579-6882-4fe0-99df-e24de9c65317"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b382cd30-cce3-4cb8-80cd-29c920cd65b2">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bdccc4d4-4092-49d4-86f8-5e49fcf7b9ba">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b56eac0d-3899-4821-b45c-ba991c2f9505"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27a851ad-9a85-4deb-865c-f7d11313fd7d"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_8b14a87a-791f-421b-9d0f-77d44dec526a">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f590be06-70fc-4603-9ae6-5d8179d8ae0a">Row 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_085d6ec3-98ea-4341-880e-ee7b36d79d6e">Concept Name may be the Root Concept Name (title) of a Structured Report SOP Instance.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 400" status="3" xml:id="sect_TID_400">
                <title>Reference Location</title>
                <para xml:id="para_3c3e3247-5676-47e5-986d-5aa2bea6ccbc">This TID is a subset of the Reference Location Macro. See <olink targetdoc="PS3.3" targetptr="sect_10.27" xrefstyle="select: docname label quotedtitle"/>.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_b1bb1e18-e1c7-4e88-a2d1-e374c0746263">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_00c271c5-bc7f-43e4-8939-b57ec5577b1b">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_bb3abf4d-55d3-4a6e-8d3a-d5333b7298bb">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 400" rules="all" xml:id="table_TID_400">
                    <caption>Reference Location</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d4eceed-ab8a-499f-b87a-b16184754b63"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e1b022aa-34b7-4c53-934f-58a2055d4f77">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_18e3b2b9-8fd6-4a65-8014-edf7e53fc051">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_03b6db29-5368-400f-b257-13d704726536">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2f0f4938-1fdc-4378-9cf1-ed6bd37fbcdc">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_09303521-27f1-4214-bce0-d7e34230d6fe">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0dfd4cbe-6c5f-4d4c-a425-8467b9860c3d">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_03c4294b-9624-40ed-9c1d-f64befce0ea1">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8c3b4c13-9abf-45b7-a685-26dd40c27794">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f409cdd5-5159-4286-b78b-501422a5500c">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a9cc433-de14-4514-84c2-f7d2c349bb02"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e33a130e-a81b-4d87-8db9-c26525a3a828"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b44fe044-086d-4b0d-b1be-911481d70052">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2392124a-e4fe-41fb-976c-b6f5fe6799f9">EV <link linkend="DCM_128772" xrefstyle="select: nopage">(128772, DCM, "Reference Basis")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e002e07c-41bc-44e3-afc3-8519a7435218">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_77a2c866-fb09-4e27-aeea-c6dd62b0c902">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2945cd4c-8820-4d6d-af2a-e3c288d9de9f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22e80ab7-e5ee-4f86-8a74-9a4966bd99b7">B<xref linkend="sect_CID_1001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c3778b4-7672-4c83-819d-cda74428d5bf">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97917f1d-c06e-4ba8-aa68-3f76d49d44a7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f4af3c9-3e51-4eff-9735-b03ebc41f3b2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4990676-1366-4565-98ad-6fa9ef7b4e10">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_89f10ee1-a739-45e2-836f-1c5536591147">EV <link linkend="DCM_128773" xrefstyle="select: nopage">(128773, DCM, "Reference Geometry")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b0311937-0d51-437c-bfd6-546e1c186ec6">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_105ab55a-cf4d-4baa-ac91-c533cda7e985">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f91cc3af-7f9a-48bd-9ec1-cb674de2cd9e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ff6ac3e-6ddf-4ef5-8940-8abbad2a8b91">B<xref linkend="sect_CID_1010" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 1000" status="3" xml:id="sect_TID_1000">
                <title>Quotation</title>
                <para xml:id="para_2e388610-c914-4d48-a2ab-604e40fba8ea">Unless otherwise specified, content in an SR tree is "directly" observed. When material is quoted (from a source that is either a document or something spoken), then it is necessary to specify:</para>
                <itemizedlist>
                    <listitem>
                        <para xml:id="para_0904e1a4-0e89-4fc3-996e-d857b1950062">the fact that one is quoting</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_a8a732f1-e7b7-443e-8f08-fa2cf0dc10e9">who is doing the quoting</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_1815200e-ffca-4935-9ac3-ccdda6945a73">the source of the quote</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_877bfd01-0aac-4e81-965f-1afc8d630a74">who is being quoted, and who and what the quote is about</para>
                    </listitem>
                </itemizedlist>
                <para xml:id="para_25577524-8578-427d-924b-af33f76ac3d9">This Template establishes a mechanism for quoting by specifying:</para>
                <itemizedlist>
                    <listitem>
                        <para xml:id="para_ea563367-6c81-45b3-84d0-1993d882308a">the fact that one is quoting, by the presence of the contents of the Template in the tree</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_6c3bd730-1df8-4987-9414-5352484df5c5">that the "observer context" above the invocation of this Template establishes who is doing the quoting</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_f9c7061c-93d4-4099-a3ad-a3fdc83c024a">the source of the quote, by the values of the Content Items in this Template</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_4a22777f-e11f-499b-8efa-454dcb90dab0">who is being quoted, and who and what the quote is about, by the observation context that is established at the start of the quoted material</para>
                    </listitem>
                </itemizedlist>
                <para xml:id="para_e4e4a990-3856-4714-9243-f214b738831d">This Template may be invoked recursively, to nest quotes within quotes. In essence, the chain of who is quoting whom can be established by maintaining a "stack" of observer context.</para>
                <para xml:id="para_07bb2000-f405-4dad-aee4-5f698a34a65e">If a dimension of observation context is the same in the quoted material as in the enclosing tree, then the observation context does not need to be respecified (e.g., the quote may be about the same subject or procedure). Typically, the observer context would change (unless one were quoting oneself).</para>
                <para xml:id="para_f5730948-0178-4277-800a-0174634c1a94">In the case of quoting something that was spoken, the "observer" is the person speaking.</para>
                <para xml:id="para_7d4f6c1d-6dca-4c94-bd93-426557881900">TID 1000 is attached using HAS OBS CONTEXT relationships to the top node of the material that is being quoted. The presence of the Quoted Source concept signals the fact that the material is quoted rather than directly observed.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_68826a22-a73e-4893-92fb-0497fd7a53d1">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f0459b4a-c0ac-4f4b-9df9-eb06df1b87cb">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_a0ace4a4-c4ba-4123-9129-c71a00d0cdcc">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1000" rules="all" xml:id="table_TID_1000">
                    <caption>Quotation</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_32bb0515-7451-45ac-b950-530514d6c918"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d948760d-5ca3-41d9-8c56-b5400d9c92a9">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f66caa3b-9279-47af-8805-e5e00931a289">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_04196e84-3bf9-42d8-a8cb-6daf096a894c">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_44b7fc11-c951-4556-8ae4-673bc52df4fc">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_886a6e2d-2620-4b0e-900c-4e426ac5c341">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_99c10def-a75e-47f4-a2d9-f9c849027baa">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_44c32d39-5bd8-40a5-8adc-83d1ae9c33ce">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f60a603a-a98b-4fb6-97be-0489e7d866bc">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ea3093c-2530-4aa2-b25e-94987478dc1e">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d503cca-16f6-46e2-94bb-f3b8b237a3e7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a16b286-1026-4a2d-b0db-2043286f8c5d">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2dea8585-516e-4d44-863a-31dddb1b208d">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37c9cf6c-8fc1-46a2-b864-0abc175773c0">EV <link linkend="DCM_121001" xrefstyle="select: nopage">(121001, DCM, "Quotation Mode")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2d33debd-9fa1-42bd-a7dd-8633f8f50660">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3bfe294d-41dc-4a70-ad65-6edb700f528f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29701cf0-213c-44bf-8dc4-f818b25b562f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cefcb5cf-e4fa-414a-ae08-90dca090a582">EV <link linkend="DCM_121003" xrefstyle="select: nopage">(121003, DCM, "Document")</link>
                                </para>
                                <para xml:id="para_f4444c84-8517-4659-a993-58265f2b0769">EV <link linkend="DCM_121004" xrefstyle="select: nopage">(121004, DCM, "Verbal")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d81f66b-775d-4d34-ae40-e6a678686d8f">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27ea16c9-2587-4441-b953-fb775e7e9b92"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_560eb55f-9463-4369-93ad-46155d5785ee">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0da7b17f-072f-4130-832b-6bfd47ca59b5">COMPOSITE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2e03f1d-fc6b-4531-93e8-84f5e673378a">EV <link linkend="DCM_121002" xrefstyle="select: nopage">(121002, DCM, "Quoted Source")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c6f221bd-053a-4b37-b122-5437249fdb12">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_39d519f9-e310-4414-972e-bf8ea3e56d6f">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ac936c3-76b9-43a1-a884-e1fe500a36fd">Required if quoted material source is a DICOM composite object</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03f562fa-0bfe-4c2e-bc6b-54348acd0e7b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52f5f68a-e8b7-464d-a034-539218b41be6">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b668836-7de5-40f8-9a3c-84e4e31cc362"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ced49c68-4cdf-4b73-9758-57592fe88057">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_153e8a98-2cd9-4476-bfd1-f85a09ce6580">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8661db9f-33e0-4c35-995b-88af3c8a0a6c">D<xref linkend="sect_TID_1001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4aff8511-feb8-44de-927b-b7a43fe3e52e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9fc56133-57a1-4f12-a7f6-f7bbf4618718">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1de4dba-b58b-4d79-8600-3718dea49411"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de7ebe67-c3bd-4268-9663-fe14afc44a69"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 1001" status="3" xml:id="sect_TID_1001">
                <title>Observation Context</title>
                <para xml:id="para_600048b3-3082-4ee3-a780-4ad14e8772e9">Specifies attributes of observation context that may be defined, extended or replaced at any location in the SR tree.</para>
                <para xml:id="para_a6107e8d-06e6-4451-8825-498e9eca5e1b">This includes attributes that specify:</para>
                <itemizedlist>
                    <listitem>
                        <para xml:id="para_3ee1fa10-9be4-4a93-9bf2-8610a0670a00">who or what the observation is about ("subject context")</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_32ad5ace-68d2-43cf-aff4-e74bc2b9ca5b">what procedure the observation is about ("procedure study context")</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_a324ce34-6c45-4515-b6e5-124600aaeb57">who or what is making the observation ("observer context")</para>
                    </listitem>
                </itemizedlist>
                <para xml:id="para_f28b5abf-25a7-45ec-8655-68f148c44f48">Establishing context includes two aspects of each dimension: identification and description (e.g., patient name and ID vs. patient's age, height or weight).</para>
                <para xml:id="para_e9a4b357-0166-4cdc-b95f-23084823044a">Whenever one dimension of context is changed or an attribute is added, all attributes of that dimension of context are "flushed", that is they need to be repeated in their entirety. For example, when the subject is changed from patient (name, id) to fetus (number), then the parameters of the patient are discarded. E.g., the patient's ID does not apply to the fetus.</para>
                <para xml:id="para_f3b0b834-023f-4c4f-84f8-6263a45ae8b3">"Extending" the same class and dimension of observation context isn't feasible, since one cannot "null out" or remove a previously set attribute. Any time a dimension of observation context is "replaced", any attributes that are unspecified remain unspecified (i.e., they are not inherited).</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_dd0f3c71-cb85-4ec7-8661-665e5628373a">
                                <emphasis role="bold">Non-Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_7b6e9062-608d-4eec-b5ed-8a7059e233a3">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_0dc0a414-0124-4c12-8e45-c07e0791cea1">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1001" rules="all" xml:id="table_TID_1001">
                    <caption>Observation Context</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6d379897-2f67-4f7c-8392-e03547ded313"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7b6a09b0-7f5b-4738-9511-783885d82c3b">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c4852f32-e608-4941-b5e2-b7c8ebacd305">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5579c447-c7e9-4903-bbff-4c53c1745ec7">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f24172d7-4a2f-4f7a-92b4-d1843bffe5ae">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c8f5b6b5-d3cf-419a-a4f7-3ec154d6aad2">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_683ec5de-b975-4a6b-b56d-91953640c054">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d662691d-7266-410b-9c35-37b10f1a1ba4">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1de093be-a0c1-43df-8b70-5fb5a96943ec">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec9a2417-530c-4a63-8637-629af5930a35">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f27a8645-8565-4d44-b6ea-0cdaef7c386b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_970a2f20-cab1-47e4-a986-b7d5b85d3f15">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec25560e-dd18-449e-b262-bb77161b95b0">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0425e7ac-7f8e-4ac7-b965-72c85940d5f3">D<xref linkend="sect_TID_1002" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_066966c7-1e9e-4b9b-a9fe-bf857e99d838">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_06cc3710-d469-4e8c-a7cc-5e8400af6970">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7a613d00-bde4-4975-befd-25f1c72f005a">Required if all aspects of observer context are not inherited.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7afe0b3-b354-433d-be4b-e39a3cd8ad33">Defaults to the Attributes of the Author Observer Sequence (0040,A078), or the Verifying Observer Sequence (0040,A073) if the Author Observer Sequence is not present</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_693663ca-827d-451b-987b-94cb3ea2f7ec">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ec27d38-c9c2-49aa-9a10-aa43482e5f76"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd671a6d-936b-4cff-a268-2197d459d383">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e07c7fe8-4d0a-46be-b40f-1f0bf70b6a90">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d84f9c62-3623-40db-b255-a7c950603d70">D<xref linkend="sect_TID_1005" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6dd31107-84d5-4443-9e8e-40498387c152">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_efd91743-cc96-496d-b876-b1e99e2ccdc9">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a99e28c-273f-44de-a441-0bac351d60dd">Required if all aspects of procedure context are not inherited.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1448471-bbdb-4c4e-98f5-1baafb8cb3e1"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bbb8decb-2c43-4729-96d6-49df8b3b285c">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24fca336-ee79-41e5-81c6-19afddba8bc7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_585d9a97-3a3a-4400-a41d-b22b6504b4e7">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16a13867-59b1-4fbc-97a0-4390b97bcc33">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dbd19920-faeb-4ecc-93a6-4ef29fef5275">D<xref linkend="sect_TID_1006" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a1c9bc98-1a6f-45a5-9d1c-ed82855c2e4a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d37a3ecb-42d4-4071-a310-d223c859bf88">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2463576f-0117-4efc-bec4-7a7f93f44873">Required if all aspects of observation subject context are not inherited.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_acfa8a09-beaa-4d34-9e81-ebc0e1e71f8b"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 1002" status="3" xml:id="sect_TID_1002">
                <title>Observer Context</title>
                <para xml:id="para_8006823b-e63a-4023-bede-1bd6bd2ca7dc">The observer (person or device) that created the Content Items to which this context applies.</para>
                <para xml:id="para_bdb20e20-ab36-4091-9635-fbc73c243551">Whenever this Template is invoked, all previously inherited attributes of Observer Context are discarded and replaced.</para>
                <para xml:id="para_b5a2daa1-e23c-4e13-9351-2b3439135994">There may be more than one observer, as this Template may be invoked with a VM 1-n, and both person and device observers. In such a case, the Content Items of <xref linkend="sect_TID_1003" xrefstyle="select: labelnumber quotedtitle nopage"/> and <xref linkend="sect_TID_1004" xrefstyle="select: labelnumber quotedtitle nopage"/> shall be included in the order in which the values of Observer Type are specified. Since <xref linkend="sect_TID_1003" xrefstyle="select: labelnumber quotedtitle nopage"/> and <xref linkend="sect_TID_1004" xrefstyle="select: labelnumber quotedtitle nopage"/> both include a single mandatory Content Item as their first Content Item, which observer is being described can be determined</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_afca58f1-1f0e-4ff9-8a55-19ea0f7bdb23">
                                <emphasis role="bold">Non-Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_24071c33-c86b-490d-9c25-c4ab60f1d8df">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_531528ea-558c-4dce-9601-3e1a0606238d">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1002" rules="all" xml:id="table_TID_1002">
                    <caption>Observer Context</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4194aae9-2a6d-4b02-8b15-4bc2d2cf27f9"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_205b072a-58c7-4c22-8d9b-2e4baad3ba0f">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d4caa139-8e42-49bd-b821-d018539bbcaf">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c094c677-802c-45b2-ab53-2eaeb311158f">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c01599ad-eed4-405d-81a1-d3d552712ee5">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2e923b2a-16e9-430f-a891-652e4b40ed03">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_596dec5c-949c-4e79-94e1-ecfe35404b0d">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_da5216d6-b3ec-4c48-b3f8-ca2e196cc472">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eb0b9443-4cd8-4fb4-80ea-992393085405">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd7369ad-e4c8-4924-ae23-882aaa1ab502">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4132fad0-f7cc-4e6c-885c-31b918a731f9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7df20e7-f895-4cf5-b9bc-fc8812a369a9">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ef8c0aa-6145-4994-b770-13fc9010bc3e">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d355f784-1627-48f2-b5f6-d062d6dd9611">EV <link linkend="DCM_121005" xrefstyle="select: nopage">(121005, DCM, "Observer Type")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aea69d16-05f0-4279-8378-b4f8275f2253">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1455baaf-f914-4b5d-b7b1-ba74b7baa22a">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39d70865-f5fb-4514-8ebd-30b197b99804">IF Observer type is device</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a1ef6c5-c67e-470c-ab2f-0eb88526b562">D<xref linkend="sect_CID_270" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_aa850f5e-ef8e-4399-b035-94d95ddc6963">Defaults to <link linkend="DCM_121006" xrefstyle="select: nopage">(121006, DCM, "Person")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_983ef657-74bf-4895-a337-f4b28477ae56">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac259888-3bb3-4437-a892-eb3d13454b19"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80947a12-2c24-4b39-b85d-709d76b74ee4">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31dc0d51-9475-4556-8a5f-4e2fb4aa29c1">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79b66754-81e0-4aae-b11d-994ba75987f4">D<xref linkend="sect_TID_1003" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1bce491c-d15d-4f86-b72f-682b3fa904e7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4cf373ba-938f-428f-958d-dc28175b6a0c">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11f371d5-e45f-454e-9a6f-8844987c179f">IFF Row 1 value = <link linkend="DCM_121006" xrefstyle="select: nopage">(121006, DCM, "Person")</link> or Row 1 is absent</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2bf241d9-20d7-4aea-8039-6350a277156b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b9c96d70-0a18-4bcb-b512-3da334bfa110">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df6f56d3-e8a0-43d6-a7ac-068006c8e224"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57435f8f-f787-4a6b-9537-54be8af5766d">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0c895720-b0b1-46a9-9e41-9998cb44c3f1">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f62c1f6-b6bc-4650-8e37-4a23797c45ed">D<xref linkend="sect_TID_1004" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_163b7ce9-d647-4be0-aa94-dc162124e9a7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1849c8d0-0f99-46d5-b11d-a75f62c0639b">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52f128f2-f8ed-4571-878b-ec0a4e428a39">IFF Row 1 value = <link linkend="DCM_121007" xrefstyle="select: nopage">(121007, DCM, "Device")</link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_539fb364-3889-4fc2-8b4c-9d6c8d2a8679"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_53b48315-dccd-4263-a7e3-f28a2f8d2005">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25a21689-350e-41cc-9f45-2f238f359a72"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a195b64-d50c-42f8-9f4d-259251a0c3eb">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf32307e-15b5-4a24-b566-d4ffd6ad0bb2">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_056150ec-3f2f-41d9-aaea-6068d821b0af">D<xref linkend="sect_TID_1015" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_12d83996-ec87-42db-b275-5bc85a9f0c89">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8e5d6bba-920a-421f-9042-942c7fb94a37">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3870c89e-fbac-4ae9-8b2d-da21f77c392a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2cce6fcd-b83a-4b26-948c-5c1ac33c0ffd"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 1003" status="3" xml:id="sect_TID_1003">
                <title>Person Observer Identifying Attributes</title>
                <para xml:id="para_f546658a-db77-45b4-bec6-fe0fc143b928">This Template contains identifying (and optionally descriptive) attributes of persons that are observers.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_437a5d3e-a505-4b7f-ae86-3d8549890a30">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_61151373-1a01-4109-b705-337fcc81ee70">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_db528288-7d60-44aa-a3d5-8f38456573c6">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1003" rules="all" xml:id="table_TID_1003">
                    <caption>Person Observer Identifying Attributes</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d62a8a19-4474-4693-8bbe-dd9055fac761"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a10b74d3-3cf1-4066-92e1-79d9bb1fcf85">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_40fb3216-d9a8-4199-a0ef-ae21ccf0b722">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2243cbce-254b-45df-ac41-26939ddb52c4">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b1ed926e-07f6-4a3b-975a-58bbf6e17a9e">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3c9596a8-871c-4874-8e43-aa2ba72d69e5">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3ea949bb-3eb0-4228-a61c-e223f55a7581">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2b5f5ba2-098f-4da9-b8bc-ba98fd18919c">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ed8bd6b0-e128-4e21-921d-f12565f346cb">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba871c2e-17ea-408b-98eb-3593115483ae">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc1900a4-be7f-48a6-8f76-015ae4e0ffc1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79e815bf-40d1-4904-b019-f67484644a72"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d762f92-f577-429e-9fa5-3c4f635bd9f4">PNAME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05b4a322-97f6-4f25-a7b4-6a3f8dafd0cf">EV <link linkend="DCM_121008" xrefstyle="select: nopage">(121008, DCM, "Person Observer Name")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0cffa899-8d39-4da7-8597-f57bde615d86">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2884efd0-459b-42cb-948e-0f6f506fa82f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8431b0d7-5b3e-4ec5-8eb7-62380ccb2331"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_441cd9ba-d604-484b-9ca4-5ed0de8f29b2"/>
                            </td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1">
                                <para xml:id="para_71fb3d7c-5d18-4794-b433-9b66b545a994">1a</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_fb60b6ef-cc4e-47ce-9f8e-4cb164099576"/>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_9987282b-fbaa-4c5a-b5e4-4950ec3817df"/>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_b68fb845-88d1-4e8f-ba17-0333ff87dda4">TEXT</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_e56ad487-4fbb-4320-bf34-5c19c1702eab">EV <link linkend="DCM_128774" xrefstyle="select: nopage">(128774, DCM, "Person Observer's Login Name")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1">
                                <para xml:id="para_5f1b8915-c12b-4c1d-9229-2d8b3c86c9b7">1</para>
                            </td>
                            <td align="center" colspan="1">
                                <para xml:id="para_dd58d308-b8bc-4e54-a371-3378bf41d2fa">U</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_a6055565-be58-4420-9dff-6e7e7cccbfa8"/>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_ee988876-a37f-4fed-998c-99f2c08cf114"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c38758b2-8e3e-487d-8395-d47d36a089df">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af7c1b46-4204-4233-bd90-bc2cd296e367"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e33e666-eafb-4cc0-9e60-4f4d96c2f9cc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7cd50b40-3bb3-4310-94b9-54ae3e13de1e">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_01243df0-f4b1-4665-9756-900e446b09ab">EV <link linkend="DCM_121009" xrefstyle="select: nopage">(121009, DCM, "Person Observer's Organization Name")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2e56da29-ab68-4845-9dab-460a00e8a278">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3f336bff-0342-4d0b-86b1-7c456d43366d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ba2bd5f-5839-4e3d-a126-779d3139bad9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9bfee9fa-d885-41ff-a833-7b7290297b11">Defaults to Value of Institution Name (0008,0080) of the <olink targetdoc="PS3.3" targetptr="sect_C.7.5.1" xrefstyle="select: title"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2772bbb7-998b-463b-a978-c57b0dfcce9b">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b29c8c9-f217-4b36-be1c-b15c98deb7e4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa5b4dd8-87ec-45ee-b916-437775c1daa7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00df50ae-70d4-445b-8603-33b56acccdfe">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4faf0e5-d7d8-4208-adae-e4caa8ebdeeb">EV <link linkend="DCM_121010" xrefstyle="select: nopage">(121010, DCM, "Person Observer's Role in the Organization")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_99ebb6e4-3298-467a-844f-dade36b1a488">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_396ab811-2d3f-43f7-813a-d40f722b32d0">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_307da607-ea8d-4dac-b981-9bf18aa2851e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f74bd095-083e-461a-9fe9-b5f7808ac89d">B<xref linkend="sect_CID_7452" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4845ea0-2834-4c5e-91c2-323a05669943">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_495f6648-a341-4d9e-babf-348d1a8985bd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd203ef1-a2b0-4c4b-a90b-0ae91ca57dfd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_817da0c8-1980-4ad0-9e50-43048b3d0e0c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_90cb85b9-239d-4918-ae77-ccb7b154b593">EV <link linkend="DCM_121011" xrefstyle="select: nopage">(121011, DCM, "Person Observer's Role in this Procedure")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_af224834-ae3a-413a-82b5-5455ad36d53c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c5534bc8-3d96-42ef-9e78-c76baa3114b2">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb15d9a9-9f60-48bb-8edb-80b4e38878bd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_734a31c5-8013-4784-abad-42bd7e2debc8">B<xref linkend="sect_CID_7453" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c4d2f72-9276-4bf9-b3f5-6bf5df9827ed">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0c63e4a-262d-488c-85c5-b67bab2246b0">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_298d94a7-ac4d-4bc1-ad1e-6fe0a5c401aa">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a331e96-3ef9-4f07-8c10-a110ec9c9065">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f095529-3107-41c9-8f58-d0b8bb103a84">EV <link linkend="DCM_128775" xrefstyle="select: nopage">(128775, DCM, "Identifier within Person Observer's Role")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d2c85db2-9da7-4a6b-a711-828c7ba75637">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9099521e-2674-487d-9c46-733c3104c535">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e1f5fbf5-d1cf-474f-9dc0-5da041110d5f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55e6ecbd-fe1d-4626-af15-b6e31ab428e5"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7dee31bf-932d-40e4-a2eb-48922b3d9c5d">Row 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4453c43-9dac-4c59-8f29-0260eaca089a">E.g., "1" or "2", or "A" or "B"; should not recapitulate the role (i.e., should not be "READER1"), since it is used in conjunction with a separate coded concept for the role itself.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1004" status="3" xml:id="sect_TID_1004">
                <title>Device Observer Identifying Attributes</title>
                <para xml:id="para_95bcb6ee-14a1-4c7a-98b9-3faf6a599f99">This Template (derived from the <olink targetdoc="PS3.3" targetptr="sect_C.7.5.1" xrefstyle="select: docname label quotedtitle"/>) contains identifying (and optionally descriptive) attributes of devices that are observers.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_5adf399d-4cd7-42d0-bef5-2b17dcccd690">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ad4fce4c-3119-4d9b-b993-4942003a2870">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_773233d8-ed9d-4848-b1da-3a7eb987bb36">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1004" rules="all" xml:id="table_TID_1004">
                    <caption>Device Observer Identifying Attributes</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_998c632b-ffa1-4706-878c-c5980cb14b3c"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d901ea42-31b2-4335-b2e3-469a1674ff2b">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7ce97f68-7d6d-46e3-9363-0918d5ade6b4">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2c28a913-bc64-4992-86c9-ab5366842f95">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_21ea7a5a-3d99-4b5b-99d8-c6d30be5db23">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b09bfcc-3587-4885-aaf0-2e959f92e061">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3f75a7cf-d248-45e6-9ee1-e83a12a1b0c1">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_600a9e5d-7ac9-40d1-b955-930495b40aa0">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2dc484be-c81b-4ade-8d57-102b6be3029e">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ae38c41-8936-4040-8365-2c5629658a56">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f15a6143-7bf6-46ac-a526-6902d2050508"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b0f2c5c-81b2-4024-8e95-cfe02d1946f0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a4b4372-8820-4005-a4a0-40cc74f38783">UIDREF</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa0e1cf0-06e0-49b6-8fca-2c9c8d878307">EV <link linkend="DCM_121012" xrefstyle="select: nopage">(121012, DCM, "Device Observer UID")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3dd1bc67-0dd7-43ae-affd-fa9662841b87">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_77741058-db73-4103-aced-ef05697d06c2">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f8ba038-c65e-4ed5-a019-3aef938c2a04"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05939ac9-08f7-4696-bbbe-78f1be044598">Defaults to Value of Device UID (0018,1002) of the <olink targetdoc="PS3.3" targetptr="sect_C.7.5.1" xrefstyle="select: title"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ed4a575-dffd-4dfe-9966-15a4205d51ce">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b2930a2-8796-4311-ba4c-57dfc64a8b75"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3dc7207b-5c74-4e2c-a0c3-de5b29116305"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ffd1f1ea-5244-410b-bfab-e43a2bec627b">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_47c9b8e6-2426-40dd-9389-497b61c20ee2">EV <link linkend="DCM_121013" xrefstyle="select: nopage">(121013, DCM, "Device Observer Name")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_13b078fe-f81b-4e40-97de-42c91b13a255">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9f912288-c95d-4cf7-90c1-82fb180a03d1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6165b8f1-b6e7-431d-943f-db5c8029f77b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0bbe9b66-3f26-49af-b226-a660b38f599d">Defaults to Value of Station Name (0008,1010) of the <olink targetdoc="PS3.3" targetptr="sect_C.7.5.1" xrefstyle="select: title"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8962cf7-d9ab-4223-8a18-577286ac270d">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8af1c338-0bbe-4d73-b376-f3e3410ccb95"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c3e8d16e-4aef-406f-9568-f0c70fc2cf1c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df003044-51fb-4469-b7d1-3fa706520c88">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_736b7b31-fe93-4779-8933-725c9647978e">EV <link linkend="DCM_121014" xrefstyle="select: nopage">(121014, DCM, "Device Observer Manufacturer")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5dc23aa1-3b91-4ef9-8e68-6f6ae7e591d0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e3a02ab0-9d6f-46be-bf0d-975eab569846">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_95dee297-b3ef-413b-9efd-5077a2d8652c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_07bd9cd3-09f3-4e1a-98d0-9795aadbd7ae">Defaults to Value of Manufacturer (0008,0070) of the <olink targetdoc="PS3.3" targetptr="sect_C.7.5.1" xrefstyle="select: title"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a1db2e25-d148-4ab5-b3eb-ffcc159fabc2">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf701443-8c15-4487-98e9-abb22ee1ed21"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e41cb39-03c1-4aa4-af1f-3081805d4b99"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c700d0b4-bd9a-4596-b38c-6c07092ecced">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82462224-1e5c-479a-a6c0-1f89bba42238">EV <link linkend="DCM_121015" xrefstyle="select: nopage">(121015, DCM, "Device Observer Model Name")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6e54264b-c64d-49d7-b6f5-d19e7a6b4827">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_11ca1e5b-bb7c-4c16-857f-9d778774505c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5fdf1b69-e97b-4b8c-8008-663207027714"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e31456f-9baa-4fcf-9269-325ca2bd137b">Defaults to Value of Manufacturer's Model Name (0008,1090) of the <olink targetdoc="PS3.3" targetptr="sect_C.7.5.1" xrefstyle="select: title"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_126f9a49-2b66-4c23-ab8c-3197e11d0b62">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ceb80f0-1744-43fc-b04e-b4d963fa66b7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f8ac1d6-8d29-459e-ab60-b3268dc123de"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d005b764-fddd-4dd3-a5fd-775ff419109f">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc900166-e311-4448-ae6e-503f5ad8185f">EV <link linkend="DCM_121016" xrefstyle="select: nopage">(121016, DCM, "Device Observer Serial Number")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f792c0df-ac7b-45cc-8a4c-524e0d1c6bd4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f256780e-3686-499f-8014-d8f305bd3327">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48fb10a9-9ccd-43a7-86a4-b22e35faad58"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96069f72-f8ae-4070-851c-0401c245e1d0">Defaults to Value of Device Serial Number (0018,1000) of the <olink targetdoc="PS3.3" targetptr="sect_C.7.5.1" xrefstyle="select: title"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc794d57-4141-452c-8594-0c7859f240c8">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_19a32f73-2888-4a81-8322-bb16739777c0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7039ab18-b235-4ee3-b468-fc4c2af9d99a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac4fef4d-64e8-45db-b716-3d4d31d269d1">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_126cdfa2-e3e3-4164-bd16-c85f4403ea6c">EV <link linkend="DCM_121017" xrefstyle="select: nopage">(121017, DCM, "Device Observer Physical Location During Observation")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_58d76192-dd52-4ee1-8ad0-d10dc9184bd3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_de9e431f-808b-4382-84f2-324dd3535e3e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29a6300e-47a0-4231-8ea6-99cabc4b9c7b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72783c62-056a-45bc-9b20-f0a4f582a480"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d2cfd2ec-009e-4e47-862a-b34ccba18eaf">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c695f100-bbe8-4341-83f9-2b0a7bbae4e2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7da134da-c810-4e2f-b27b-cf0b392801ec"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d1dfbab-e598-4489-990f-99e606992479">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_33dc3a37-1c04-42ab-ac33-6a3a90b91eb4">EV <link linkend="DCM_113876" xrefstyle="select: nopage">(113876, DCM, "Device Role in Procedure")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_beecfd74-5828-4b71-8c38-8373e18b7138">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7c8c69fc-c298-434a-aa37-14320e9a30fb">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b0c988a-d27f-4242-9ff1-999464ad46d8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_575cc6d4-1781-4288-9bbc-eb4af3e4484e">B<xref linkend="sect_CID_7445" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd87d5fa-139a-49e9-bda7-8937491ac90b">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e0567e9f-b3a6-48d2-9877-97d53b449b6b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ade2904-a56b-4121-9c04-c64f9f5c73fc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2d887451-c7f2-4749-a267-103b83973893">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a920da4-1c15-4bfe-bf07-c1707cb1a41b">EV <link linkend="DCM_110119" xrefstyle="select: nopage">(110119, DCM, "Station AE Title")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_efee1e69-360b-4e78-8878-104bb4824bd4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ce8ba024-5310-4b5e-b698-34abf8b11fdd">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed98fa2c-5759-4599-8006-1a4c6ce294bd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d07bb54-e772-4d02-8d67-61e6f7297851"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_245a450c-b43b-4c11-9154-08422672c8aa">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef6bb1f1-d561-4f0d-b5eb-cf0512f6b635">UIDREF</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb750f8b-2c39-4fb7-9cac-c7ebadbaae4d">EV <link linkend="DCM_121061" xrefstyle="select: nopage">(121061, DCM, "Device Observer Manufacturer Class UID")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2c31389c-22a1-4377-bbb1-4ae3bc0452d7">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ddaaf8ed-9d10-4cea-9db3-75986b5eadbb">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_463af347-005b-43ee-881a-46dbee071a9d">Defaults to Value of Manufacturer's Device Class UID (0018,100B) of the <olink targetdoc="PS3.3" targetptr="sect_C.7.5.1" xrefstyle="select: title"/>.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_14755876-d97a-4cbf-9e0f-c8457ee30874">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_95a117d3-9c42-4489-b4ad-95a186587d64"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9acef7c3-769d-4eb4-934a-e9cbcafdc3cc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7180a2b0-bf69-48a7-af67-f5b9c446e23e">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f70e1da0-a61f-46e2-b152-6ccd556407e4">EV <link linkend="DCM_121000" xrefstyle="select: nopage">(121000, DCM, "Unique Device Identifiers")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ccce33bc-ac50-4b58-bc4c-a7ad1841dfcb">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f52c8d6e-1261-4a43-8cee-0af310d87c8b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fbef569e-9c24-487f-8ddc-84c3021f1606"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7fdbc06-4765-466b-af39-2e6e54d16a59">Defaults to Value of UDI Sequence (0018,100A) of the <olink targetdoc="PS3.3" targetptr="sect_C.7.5.1" xrefstyle="select: title"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cabc9623-8136-4e12-97ba-d9b42cdeff91">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d19f2637-fb34-4dda-8db1-3404a7e07d81">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_94da57d6-c988-4f74-8d06-f4f12a1342b4">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd676f4f-5df0-465b-a4a0-eeee0c954b12">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_311b571d-8626-4f96-bf15-438024ecd380">EV <link xl:href="http://loinc.org/74711-3/" xl:show="new">(74711-3, LN, "Unique Device Identifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2597020c-e30d-47fa-bb56-d30c0df451d8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_60f9c8de-e7a0-404b-bacf-7f1417e438b1">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b8972b0-e9df-447b-95d1-902a93b08c36"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f47e2077-4261-4c5b-b7a3-fea7ba9019ea"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42e8e90f-be50-4342-b97d-3200fcc30ff5">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c2de6da-7de6-46a0-9cd0-3ecf13c31ed2">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75430fab-7020-47c8-83b3-13e7e02e7e1d">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3cbe794-09d6-4b0d-86d9-347ccb09f6f5">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce36f6a9-6c9c-42fe-b724-01ca733da9ca">EV <link linkend="DCM_120999" xrefstyle="select: nopage">(120999, DCM, "Device Description")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_80724db9-cafe-4305-b235-96307d081a65">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_22426818-ac8b-4ebb-929a-3fe1170168a9">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d24e4138-77fe-4d94-811a-f2e55965a98b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b692699d-8a8d-410e-9744-b3818f5bdd86"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_934ac9e9-1e4e-41d4-ab09-be7a22d5a708">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f95e61a6-1df1-4c5c-9e39-5006e0454f92">Row 7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ad5df1e-79a9-4580-9626-439adc752db7">If the device performing the observations has other roles, e.g., as the irradiating device in a dose report, this may be recorded here, if not implicit.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4a80587-3fd5-48b3-82ed-274c7bfa7630">Rows 11, 12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9ba9bbd-3d36-4036-a54f-1d1b87130024">The description can be used to distinguish between multiple UDIs.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1005" status="3" xml:id="sect_TID_1005">
                <title>Procedure Study Context</title>
                <para xml:id="para_6195136d-4d74-4be6-b0f9-0f49f3b6ddba">This Template contains identifying (and optionally descriptive) attributes of the procedure that is the source of evidence being interpreted.</para>
                <para xml:id="para_38b79227-8d57-4d5f-be40-217a291d867f">Whenever this Template is invoked, all previously inherited attributes of Procedure Study Context are discarded and replaced.</para>
                <note>
                    <para xml:id="para_f9acb290-2c32-4ee0-bdd5-180c1d4d1fca">If an observed digital image is identified by other than a DICOM UID, a Study Instance UID must be generated for the non-DICOM evidence. The same must be done to document interpretation of hard-copy radiographs generated outside of the scope of the DICOM system.</para>
                </note>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_20bab028-0f92-4e9d-b0be-a815713e2057">
                                <emphasis role="bold">Non-Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_567f3b0f-351e-4ef1-8969-7595b5ff5c6e">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_db78a860-f951-4dac-97ad-6b8e5821938d">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1005" rules="all" xml:id="table_TID_1005">
                    <caption>Procedure Study Context</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1642662f-741a-440c-ad92-f3692da1b66a"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d92e9ac5-5f40-4167-8b63-71d0c0e42b52">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_250924b8-072d-479e-b8b0-5c6eef1f3973">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c304eb76-8101-46b9-98fa-460cb927aacd">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f3c14689-d053-463c-8201-b8ea3455cd10">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d14c6330-c8d8-4130-91a6-597c3d0992dc">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4c19fec0-1e59-4fdc-b21b-309ff409023e">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_65dfba17-312a-4e33-ac85-4fa058385c42">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_42afcbc4-c2fb-46f1-87a2-aa945f1cf019">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b15ce4e7-7121-4208-bf9d-5d97c0c6c918">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f986360c-2112-4391-b9b7-3edc43eb4c58"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c8191ed-e33f-4e9f-b5e8-efc7a6ed2ac5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d99ed459-cdb4-4bfe-8b6e-994045a72a51">UIDREF</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f24d33a-d854-4993-94ad-7ceea2d7218b">EV <link linkend="DCM_121018" xrefstyle="select: nopage">(121018, DCM, "Procedure Study Instance UID")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_62314c1b-1deb-4841-b752-30a975b802fc">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fa604bab-51dc-4ec4-9d26-e334e6196829">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e2f28e6-b7ad-4734-bfdd-970d6d5a5680"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a86d5e64-ffd4-40de-a296-9f7b8d2fc93a">Defaults to Value of Study Instance UID (0020, 000D) of the <olink targetdoc="PS3.3" targetptr="sect_C.7.2.1" xrefstyle="select: title"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d973db6-0bef-4ae4-9c91-be0ae0fd23f7">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_44e2228c-b5ef-4bd9-acf7-fbacd889ec56"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e08955ef-66e2-4d1f-bd2a-0753c0d1986b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_193ed483-bed5-4a21-8bcc-22b55b6e729b">UIDREF</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79ac8eaa-a751-4818-b53d-825707c7e519">EV <link linkend="DCM_121019" xrefstyle="select: nopage">(121019, DCM, "Procedure Study Component UID")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_983c65e6-9a35-42bc-8706-c8094056f3de">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d5b12a13-ab29-4914-8423-48b714c33520">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1d46735-13c2-49b4-8f6c-cc59732e3e9a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df04d7fb-7520-406a-ae19-cfcba5b398a5"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58a74368-f8a0-4771-9bb7-6c292e382695">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25d84088-22d5-4a48-9549-bd7f7c3e5aa5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee2677c7-5988-4f5a-8a30-08bc91151acc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e248cbad-350c-4172-be61-d5dd4dfe50aa">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac58631a-4a5b-45ec-bd95-516ef8c963b8">EV <link linkend="DCM_121020" xrefstyle="select: nopage">(121020, DCM, "Placer Number")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c463a33c-6ed6-4cae-905d-6698ce1d5855">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6cb8c189-04d1-4500-82e0-e13cd011fac5">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba6fda0c-8841-4e5a-8374-79708e96741c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c465f7c4-77d1-4a1a-9080-17140fac448c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0bc8b37c-3df0-41cf-9d25-f5c568a3b6c3">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75d4c2d0-c19f-4ea9-8931-067f5e4d8e91">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a2517b8-0fa2-4573-a1d8-6493cc243a38">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_60f9c683-57ac-478c-bb59-d86a27c9d3df">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1cfdfdae-cd7e-4d5c-9599-1e5aa4be55db">EV <link linkend="DCM_110190" xrefstyle="select: nopage">(110190, DCM, "Issuer of Identifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f9083e49-1815-4e5a-9c25-a37dc755995c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7fd6fad-a20f-4a0d-a099-41ff0037e308">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d07cca29-85e8-4261-9e80-273aa7c392aa"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a7deb00-de4e-4c5f-8458-28b4e33e8a22"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_01c9a92b-d790-4f75-b302-086a537ad0b8">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_481ab8f7-9c5f-4b0b-a9b6-7cd23b40f4b6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e90bffe0-3b22-4ed4-9957-4274105114b8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00b064d2-66aa-4382-8e78-093f03112ed5">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73dd62d6-44ed-475f-b089-b449c8b88702">EV <link linkend="DCM_121021" xrefstyle="select: nopage">(121021, DCM, "Filler Number")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d9d250f6-0e82-44cf-8064-406ad3180566">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ebd41436-a2b8-43f2-907e-82904ddd6651">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8cf191d1-711f-4df1-9d08-984af82239e7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27318d02-865e-4f20-bac0-01118f321778"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_daa0e56b-7093-4f1a-9d76-dbd98774d9ae">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed4e5e31-28e6-460e-98bb-2e4fd420e37a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6964006f-cead-4e6d-9385-db8d032d2f1e">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc9fafea-d653-4a16-a195-a4cab6944b2f">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2836b129-c42b-4abc-aafe-16bde058c057">EV <link linkend="DCM_110190" xrefstyle="select: nopage">(110190, DCM, "Issuer of Identifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f6e95b8-26b1-44ac-a499-e74650b849d7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4e9783f6-fa37-4616-bc21-c5e2cc94570b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3757e84e-06c8-41c9-af43-db6200f58eaa"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5556afc0-3483-4906-a21a-8be843dd5cb8"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed566ed9-2f60-42b8-a45c-fffb42c12be8">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_23102f85-54fd-4380-9692-df5d8a848705"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91aa177b-14c9-4ebd-a996-ac58a1ebcc21"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a8973e8-282d-4314-889d-1bdf806128b9">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d041f78-9f27-4063-8d81-89de7969f575">EV <link linkend="DCM_121022" xrefstyle="select: nopage">(121022, DCM, "Accession Number")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f9255ff2-f055-4be0-bfda-78f60db06e4b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_65e7d252-ad61-4f2f-83d1-8f56d8d8531f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87603dea-ec03-4e12-9b72-6d770921d783"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3af1a25-ef67-4787-868e-ddd8a5203875">Defaults to Value of Accession Number (0008,0050) of the <olink targetdoc="PS3.3" targetptr="sect_C.7.2.1" xrefstyle="select: title"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b54b674-6256-4c75-9c95-0d7628d3f36b">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63c56e94-de90-4a6e-ad6d-6d198312c7aa">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a905abd-8c7f-4da5-8b85-12c37649c244">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5495688b-4d80-429a-b063-748f5ab32411">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6444d020-9bf7-4578-b70c-87f029b79784">EV <link linkend="DCM_110190" xrefstyle="select: nopage">(110190, DCM, "Issuer of Identifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_952d0eaf-3474-4386-8595-bfa2f5c8b98b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6737395a-be3a-49a4-9304-3eefeeb0b58c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ce1ca2e-9500-4cde-a849-a34c554cdf9b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_01a488d8-676c-401f-b1e2-2d3b8e7ad1c0"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7028d8aa-a1b7-4cc8-bd66-53308c5cea7c">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26da6bc8-fb9f-4c08-b01c-63502eccedab"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_95d7b9dd-c5da-4db0-82aa-746069d1a6bb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5e2aae6-5801-4847-999f-fcdf71d197c6">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3818d688-08a5-4b2e-9a99-5a210d6517e6">EV <link linkend="DCM_121023" xrefstyle="select: nopage">(121023, DCM, "Procedure Code")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b4c77677-b4f4-42d0-b2cc-b8b0aea371c9">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0735113c-4084-40ec-9f81-4d31f62f1c0e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f80ef56b-2970-4142-8675-d62c7871acd7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e8a82cf-b5bd-4abe-b6b1-e2e987bfa65c">Defaults to Value of Procedure Code Sequence (0008,1032) of the <olink targetdoc="PS3.3" targetptr="sect_C.7.2.1" xrefstyle="select: title"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_b4f57e5a-ed59-491f-8b57-721f14e55be7">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d69ebe44-2012-4f99-ac92-c4ad5b236c7c">Rows 5, 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e8d096be-47ac-4699-b017-75f8063a40d6">The issuer shall be formatted in accordance with the HL7v2 Hierarchic Designator Data Type. That format is [ <emphasis role="italic">Namespace ID</emphasis>]^[ <emphasis role="italic">Universal ID</emphasis>^ <emphasis role="italic">Universal ID Type</emphasis>], where <emphasis role="italic">Namespace ID</emphasis>identifies an entity within the local namespace or domain, <emphasis role="italic">Universal ID</emphasis>is a universal or unique identifier for an entity, and <emphasis role="italic">Universal ID Type</emphasis>specifies the standard format of the Universal ID (see HL7 v2 Section 2.A.33).</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1006" status="3" xml:id="sect_TID_1006">
                <title>Subject Context</title>
                <para xml:id="para_27b878d4-4efa-4718-aa55-914a4979598e">This Template contains identifying (and optionally descriptive) attributes of the subject of the observation.</para>
                <para xml:id="para_ba8285e8-39fd-4d20-b9bf-a109c4fe411f">Subject context identifies (and optionally) describes the subject of the observation, whether it be a patient (human or animal), a fetus (human or animal), a specimen, or a device.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_6361eadf-47f2-49ca-902e-22d9d79975dd">
                                <emphasis role="bold">Non-Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ee82aad0-fd60-4924-ada3-f7d198288f08">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_5467e423-d7a1-455b-b1db-d68d57cef5f9">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1006" rules="all" xml:id="table_TID_1006">
                    <caption>Subject Context</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3334d125-12b4-486c-9ea6-c2ae8e821f66"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_32d44ff9-9f93-4152-b0af-0a6fe651dcd6">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_98cf91d6-481d-489b-89cd-377dd6cf93ea">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8b4a693c-37a1-4047-a4f8-d97b8199ab10">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9d3a2576-0401-46ad-8b21-7b1a3a26b2be">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8ef91aa9-4e17-471e-b5c5-24caf9b940eb">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c83c5c78-1608-4a91-b7dc-ad9579bf702b">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e41e461e-3a79-41ad-a245-c0195f6a056c">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fc87e7a1-e795-41e0-b780-fe97274d19c9">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_41cf745b-46bd-4fce-8523-ee5dfe0d1bdc">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f970a22b-56a2-4e72-9aa9-a67b9e7f30c6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b70a40a8-1940-4d20-bf25-d213e7b2141f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46306d04-d1ab-45ca-807c-b41389fe6bee">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3bc803e6-a5f5-42eb-b4fa-3eb6ee4449f0">EV <link linkend="DCM_121024" xrefstyle="select: nopage">(121024, DCM, "Subject Class")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b1c008b1-e0a8-4fd2-92f0-0ad5b28c29aa">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fea4d62f-97f4-4b25-af99-d1847ef9da13">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f845b55-1f7c-4467-840e-1040401e5659">IF subject is not the Patient</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2615026-1617-4ce2-a980-b1383655dd57">D<xref linkend="sect_CID_271" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_08b64e82-1a40-4373-bc5d-50e7a34e9323">Defaults to <link linkend="DCM_121025" xrefstyle="select: nopage">(121025, DCM, "Patient")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e3ca4ae-7003-46af-826f-44e616565f0f">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51e4918d-fe2e-4c53-adca-942e85d91468"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_438e597d-ccf5-40b0-b910-f7d5d8c8f75a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99b497ce-4434-4d63-877c-42c95f9cfbdf">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ebe1db38-9073-473a-b1dc-46337e5a7232">D<xref linkend="sect_TID_1007" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_96b91d5c-fcfe-457c-902d-1cb2c63b8ba8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73d4d941-ec6d-4da0-ae77-16a2a5c7a7fd">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22358fe8-8909-462c-922d-923149b0a498">IFF Row 1 value = <link linkend="DCM_121025" xrefstyle="select: nopage">(121025, DCM, "Patient")</link> or Row 1 is absent</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dcdb8113-3367-4658-9620-0a697ecba7a5">May be used for human or animal patients</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f2c718f-7647-4b9c-9e92-e91266481680">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b8ba346-d41f-41d0-8e6a-7a1d12b640ef"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e436a2d-32c3-41a1-a066-8b868de1ff55"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3cb0be03-109a-4f51-9747-a80b2a347bbd">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d9bd68e-cb30-4c35-8a0d-4710ed439ddd">D<xref linkend="sect_TID_1008" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2352e6a3-47af-48e5-8d51-cd6abffdabfc">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a4e5fa34-0b28-4545-8afc-f870723137bc">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b21105ea-369a-44ec-8e35-3a46fadd6ccb">IFF Row 1 value = <link linkend="DCM_121026" xrefstyle="select: nopage">(121026, DCM, "Fetus")</link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a948cddc-a3cd-467b-a968-b940e4ff929d">May be used for human or animal fetuses</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_44800471-4ae1-4602-8ac5-ce7997d617f6">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80ab83e4-0992-4e75-9f54-ce701702b6ae"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_783b9c6c-01f7-4fc2-8d27-a07b3e7282e1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_daeb0fbb-c27f-45b5-9364-ec8aeb906cdf">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c182fe5-b5f2-4482-b6d3-d13cd2a9edfc">D<xref linkend="sect_TID_1009" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2e19897b-0b24-4ab6-bcf8-cdc0c76c8551">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eed5fa92-3b41-4383-aab5-d2b875377759">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85ff6f66-dbf8-4f2e-b81c-fcf5dc288281">IFF Row 1 value = <link linkend="DCM_121027" xrefstyle="select: nopage">(121027, DCM, "Specimen")</link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d2c3b66-d3fb-4a05-ad66-347e251de092"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb14cd9f-f7df-4b39-82ad-dd28acd6775b">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6caa33f0-53ba-4e5f-a415-6dca28aa7a4d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7d03fe8-41a1-495e-93cf-3cc6f0f82022"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5fbbd4e-3c00-414e-9671-9557269af963">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb9b4c07-affd-4652-93fe-aeced82af923">D<xref linkend="sect_TID_1010" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3037d050-816c-4f07-859c-3490237568f7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b8ee3622-4c5d-4cb2-9c7d-7264713e117a">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_47d7acd6-178e-4216-a033-e4efa099c632">IFF Row 1 value = <link linkend="DCM_121192" xrefstyle="select: nopage">(121192, DCM, "Device Subject")</link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_544dfe45-4775-4454-b6f9-fdce8b4c33de"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 1007" status="3" xml:id="sect_TID_1007">
                <title>Subject Context, Patient</title>
                <para xml:id="para_bf468c38-5fec-4320-bd23-8840a4b99ee7">Identifies (and optionally describes) a patient who is the subject.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_60f651c1-5481-4ce9-a8a3-9bcf147ecfe3">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_fbe8f43d-9364-4b4f-9949-0b5a3110768b">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_8f9a9b30-f845-4b70-a55f-f356cf574eea">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1007" rules="all" xml:id="table_TID_1007">
                    <caption>Subject Context, Patient</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cbfaf626-9734-4d07-a4ac-0aa6958258c5"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3a036833-b7d7-41eb-917b-2ecdcf0d995d">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_901af82f-5f12-455e-96dd-d7660580d658">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5b7de8b7-7530-475a-87e6-8787224443c7">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aea81ac1-0ded-411c-94bb-f9a48e915cd0">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9b38dad8-5e65-4e44-9911-505877fa176d">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_80064aea-6c47-48ad-8ebf-a4926020a288">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9af8b701-1cde-485e-9275-6909874ce303">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6162a781-0873-4597-824f-bdf777429be7">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8019b492-1fd1-44e6-8732-c7f765778080">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3192be22-006e-47b0-9272-80f0d842378d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb168607-e8f0-4e62-8c96-ea881d809fdd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e45ac586-76fc-443f-87ec-7ca703334271">UIDREF</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ab0ba85-5b97-4079-8945-aac23bdf520e">EV <link linkend="DCM_121028" xrefstyle="select: nopage">(121028, DCM, "Subject UID")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_44eec935-d3b5-43ee-95ce-62dec7662df9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8d64e418-4e74-42cb-8db6-00481b9fd2bf">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bcb64d08-0f26-46fc-b46e-5b47975537db"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd49e539-941c-4ec0-9ca6-b4094b8e8ea5">E.g., SOP Instance UID of Detached Patient Instance</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b62bdc5f-0fa7-45d4-9623-271aecb3e9ce">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f7222674-6cbb-4dcf-8d15-f14be119a27a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_20adc004-2cb7-4fa8-8ff2-840a37f19dc3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67ccdc70-7016-475b-be97-2bc1a3297308">PNAME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5cd837a-602c-4480-86b2-dfc77595374f">EV <link linkend="DCM_121029" xrefstyle="select: nopage">(121029, DCM, "Subject Name")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c7f6005b-ae12-48e9-8334-ec184bd9fe1a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fe1cd067-95c5-4830-a45a-c070578d1a43">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a909eeb-5d29-4f42-9e40-652879a6b837">Required if not inherited.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b970585-8c3b-4ffe-a8f5-8c20ccb87a9e">Defaults to Value of Patient's Name (0010,0010) of the <olink targetdoc="PS3.3" targetptr="sect_C.7.1.1" xrefstyle="select: title"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8bfd02b-567c-436a-b6c6-a5c938dd11b7">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6196223c-988d-4e11-9047-ebd35cb707d1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c20cd71e-e02d-4053-b6f3-bc5e5a7f60fa"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f004ceb4-a948-45bf-b4b9-6036c5ee53bd">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_14c5a87a-f282-4aa8-9bb7-447651c43256">EV <link linkend="DCM_121030" xrefstyle="select: nopage">(121030, DCM, "Subject ID")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a94a5d71-e7c8-4d36-85f9-5c6192d2a2e9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e76dc6a8-aa63-47bb-b0ec-28284b3cf7d6">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae8ae22f-5f7b-4a18-a071-c76584d9e970">Required if not inherited.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be905d69-5b6d-4f67-800e-5d471225b3f5">Defaults to Value of Patient ID (0010,0020) of the <olink targetdoc="PS3.3" targetptr="sect_C.7.1.1" xrefstyle="select: title"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_501d1342-373c-4dfa-9d30-b27055259fc6">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_027507be-2dc1-41af-a9ef-fc489d6bd050"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_898cbf88-ed48-4999-ba4a-b985ffb3842b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c0cfd2b-9789-4b8b-bd7a-42fc04a3103c">DATE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13138785-6f10-4b88-86de-0f77ad9f6748">EV <link linkend="DCM_121031" xrefstyle="select: nopage">(121031, DCM, "Subject Birth Date")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8271616d-bffd-4a49-a662-764b8e334557">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2c863b3e-fa6e-4a46-b3fa-34b881e001ac">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d8d8e18-749b-4d74-a7a2-0ca184bc921d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70a0c58a-928c-4404-aed9-a0c44add34ac">Defaults to Value of Patient's Birth Date (0010,0030) of the <olink targetdoc="PS3.3" targetptr="sect_C.7.1.1" xrefstyle="select: title"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_749f7806-746a-4a26-b47b-1a43c0816ccc">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ac5e124-794e-42e9-867f-0559625ed8ba"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fca3d08f-6155-4802-bc66-fddfec099a95"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c4bf4dc-2b73-4648-8fbb-90a84c6b524c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a227b0ef-61c8-45b2-922e-d0f2f7e0a56e">EV <link linkend="DCM_121032" xrefstyle="select: nopage">(121032, DCM, "Subject Sex")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5d7e091e-39fe-4e2f-bead-6505c7757610">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_901ed7c9-bdc9-4d63-8298-57b0de2716ef">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae48ab38-fa67-4527-be2c-2681a08fc3b6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2d635a6-832b-4dc3-8273-c452ece78239">Defaults to a code equivalent to Value of Patient's Sex (0010,0040) of the <olink targetdoc="PS3.3" targetptr="sect_C.7.1.1" xrefstyle="select: title"/>
                                </para>
                                <para xml:id="para_04d6bbb2-818f-489c-84f3-a8b7a08e0061">D<xref linkend="sect_CID_7455" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79a0c3f8-3c51-46ff-9b40-a0664662705c">5a</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87b066f0-f163-464d-b91c-975f677888d0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd09fd02-c3ca-4f1d-9846-c78a427b2508"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba331a2f-038a-4506-8783-95c88325ff8d">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_695bfd6e-e3cb-4a5a-a10b-70c5d02c8d1e">EV <link linkend="DCM_131233" xrefstyle="select: nopage">(131233, DCM, "Subject Sex Parameters for Clinical Use")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73c73700-5f61-434a-960a-551b0a865786">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_10ab9c04-2fac-4c75-84f7-ae2bd4347f43">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d07ab0f2-18a7-4f27-965c-74e209ac0c2c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cebdc96d-733d-4d63-b361-b45894a24434">Defaults to a code equivalent to Value of Sex Parameters for Clinical Use Category Sequence (0010,0043) of the <olink targetdoc="PS3.3" targetptr="sect_C.7.2.2" xrefstyle="select: title"/>
                                </para>
                                <para xml:id="para_a300b513-627b-4e76-928d-fd6bf2f10904">D<xref linkend="sect_CID_7459" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fca9291d-627e-4b0b-a31b-144e3d870f1a">5b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca3b6dc0-ef0e-4abf-adcf-fff3dbdd5081"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_68cc34d9-8094-4219-90e8-2c4707266659"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17b71b64-68cd-4b35-b4c6-557e27703399">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1de6758-ae12-4b3c-86c4-73b3e63e6249">EV <link linkend="DCM_131234" xrefstyle="select: nopage">(131234, DCM, "Subject Sex Parameters for Clinical Use Category Comment")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a4c046ee-ae80-4024-a811-99ac8ff0ffad">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d6947ebf-c7fc-4908-8ef5-710d3e59986f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2159c80f-e3ce-430b-9a60-9b6ff25edb84"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17777599-070d-45d9-a848-bc78c08facba"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e724cdb-f9fd-4b3a-9fc5-27806f78132d">5c</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a08eab6-b7b6-40ac-8f1c-ec0e0af75ca7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d565b24-1a37-4cba-bf4a-75afc58b957d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_415f8a2b-c440-4470-ae21-0d98ffe9de6e">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2d14fc36-cea5-46e9-9812-fdfcc9d7b8ee">EV <link linkend="DCM_131235" xrefstyle="select: nopage">(131235, DCM, "Subject Sex Parameters for Clinical Use Category Reference")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9506f4bc-0347-4012-8f6e-41405ea0a4f0">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9901ad21-af26-4d7b-9fe0-08928bc036f6">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c720b270-e0b7-49f9-b2f0-202e6d2dc42e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7fda5a13-edd0-449a-a22d-06aa74c851a5"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c7b89a2-e1e9-4c52-a5f4-6eb54fcfdf34">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46576318-be77-4cbc-bd8f-55794271ceca"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3aa4002-7226-462c-823c-ae41c3163111"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7a35b5a6-5ec1-48ea-8b1b-e0453e80affa">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e03c824-c7a7-4cec-9b02-08fe62ec9435">EV <link linkend="DCM_121033" xrefstyle="select: nopage">(121033, DCM, "Subject Age")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bb361d4e-f755-424e-8c07-2258e70d4598">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3a0079da-6041-4ecb-aca5-90072b075a43">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a38f46b-0c96-42c9-b3d2-69c67edd2094"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_110dea7a-273a-46ca-9f9b-f9bc957c28b6">Defaults to Value equivalent to Value of Patient's Age (0010,1010) of the <olink targetdoc="PS3.3" targetptr="sect_C.7.2.2" xrefstyle="select: title"/>
                                </para>
                                <para xml:id="para_70dfdd7b-5815-4ec3-83f0-f7b1789b7146">UNITS = D<xref linkend="sect_CID_7456" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_655c9b84-a715-44df-9be7-869f30f75930">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b500f70-cacb-4351-82b1-516314d5db38"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a5eee97-d6fc-43c2-a63d-a5136a223f42"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39d4d93e-e665-45f8-9b96-df513f11e499">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d7b10b5-f314-45b9-be42-a3e9dba5ec1b">EV <link linkend="DCM_121034" xrefstyle="select: nopage">(121034, DCM, "Subject Species")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2950824c-8b38-4e54-9149-34e7d3060d05">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e230982f-4363-477b-9670-548c58049b60">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_40e9cfea-cb92-4eca-aea5-e40782510d01">Required if not inherited.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_502220dd-3177-4626-8a3c-ea187e44d318">D<xref linkend="sect_CID_7454" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_7bca73e4-ae86-4c63-9d52-855c6bfa2c1b">Defaults to Coded Entry Value of Patient Species Code Sequence (0010,2202) of the <olink targetdoc="PS3.3" targetptr="sect_C.7.1.1" xrefstyle="select: title"/>, or if absent, <link xl:href="http://snomed.info/id/337915000" xl:show="new">(337915000, SCT, "Homo sapiens")</link>.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73319e32-d3b0-42ac-aa41-a02febb46d2e">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_adbedfea-63e8-49f5-9db5-32c2bfa77b36"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46f0fd0a-8eee-48ba-91ca-1903c4efc87d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a243c6a0-2c2a-495c-8b3c-0e3809375da6">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc9dcdc7-d19c-4dbf-abdc-943f9257eb42">EV <link linkend="DCM_121035" xrefstyle="select: nopage">(121035, DCM, "Subject Breed")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c8b89d63-c52a-4f92-b994-94495bb150de">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d03f0de1-104d-4dd2-bfcb-fad71641c645">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5ceed7e-c8b9-4027-b243-96c5ee0aaaad"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13820a78-c051-4914-8382-08999cd56a2b">Defaults to Coded Entry Value of Patient Breed Code Sequence (0010,2293) of the <olink targetdoc="PS3.3" targetptr="sect_C.7.1.1" xrefstyle="select: title"/>
                                </para>
                                <para xml:id="para_9b56717c-5a97-4e07-8987-38fec64d94b3">D<xref linkend="sect_CID_7480" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_244187c3-3e03-4f1c-bced-a23bf7b02956">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_199ae9a5-2b85-425f-a4a5-b3e5170e32da"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8c2b899-f437-4160-a4ed-6d2b1d0fdea8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae38d44b-07c4-4ca7-a8d6-87dedec09304">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_001845b6-e368-4f4f-bfa6-92a8cb4ed4c8">EV <link xl:href="http://snomed.info/id/415229000" xl:show="new">(415229000, SCT, "Racial group")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d68fd13c-389e-49f3-8a6b-0ae19e59b592">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2c2aa631-9941-426b-9cca-2f3473987b98">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd544c37-f3b1-4262-a145-833c83ea61f0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c234fea-fdfd-40c9-93a3-8b07ead0a6fe">Defaults to Coded Entry Value(s) of Ethnic Group Code Sequence (0010,2161) of the <olink targetdoc="PS3.3" targetptr="sect_C.7.1.1" xrefstyle="select: title"/>, or if absent, the coded equivalents of the text Values of Ethnic Groups (0010,2162) of the <olink targetdoc="PS3.3" targetptr="sect_C.7.1.1" xrefstyle="select: title"/>, which is defined as "ethnic group(s) or race(s)", or if absent, the coded equivalent of the text Value of retired Ethnic Group (0010,2160).</para>
                                <para xml:id="para_296466ba-c231-41b5-8108-fba2584de6d7">B<xref linkend="sect_CID_6099" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 1008" status="3" xml:id="sect_TID_1008">
                <title>Subject Context, Fetus</title>
                <para xml:id="para_49628430-0998-4fcc-83d5-df6bbb6d02d7">Identifies (and optionally describes) a fetus who is the subject.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f15f879e-3f59-49f8-97e7-3f2b27acf5fe">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4a76c0cc-c6f1-4374-8575-ce3f4c230c8e">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_271c1fea-fd7a-4a3e-91b8-9d9a95a22cc4">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1008" rules="all" xml:id="table_TID_1008">
                    <caption>Subject Context, Fetus</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e48217d5-c54d-499c-90bd-8af36dd88910"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2f145482-4d34-418d-8ee2-9c5ee3550cb8">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_182b0bce-98d5-47e0-b052-2767187e19e4">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_559a459e-9f2a-4377-96cc-cff8a7a359b1">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f8829b40-7781-4b46-92a1-f0d82a1fe909">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_762c5b16-8c0d-440a-bf3d-a5d17415e33f">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5f63f48f-0d35-4e5a-bebc-982a4741326a">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6270159a-e480-41b6-83c8-05f9af3a54b7">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ca61f7b6-cbba-495d-b301-fb587b671e3e">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_020333d2-e5ad-483a-b5a0-831eac8fbb70">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e1d4aeb-6eb4-47a2-ad74-13033acee8bb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c85406b7-9838-430d-a00e-f777d731b845"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d45bea95-a814-4e41-8965-89ea5fe4e97f">PNAME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81f31eb9-ec8e-4594-95e5-0908993b37a9">EV <link linkend="DCM_121036" xrefstyle="select: nopage">(121036, DCM, "Mother of fetus")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_052be6ea-6cfc-4b1b-95da-9aa8f53d29b7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4c32e7cc-42b3-43df-8338-fcb7fdfd7eae">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_45defab5-03e0-433b-bb82-afed18aa40e1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3690ae31-28f6-44bd-a015-2fd41d9c5b75">Defaults to an observation subject that is a patient prior to replacing the Observation Subject Class with Fetus.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b882a1b-e9ea-4e01-afb4-53a05aa14d43">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cec2462d-cfd1-437b-a7f2-2a9f852cb4fb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_187db7e8-5b18-4a9e-a4ca-dba4e4529a9a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_095584c5-71f8-4998-a106-f0f16336b851">UIDREF</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e0ab827-bf77-460e-b6e0-d03fb60dce40">EV <link linkend="DCM_121028" xrefstyle="select: nopage">(121028, DCM, "Subject UID")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2d11549d-aa05-4c90-ac92-fe93f12ebe80">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9deddc26-fc1e-42ef-9a52-b0c226284fe2">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_469c081f-2675-4404-8499-80db7c319596"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fcf88909-0cf9-4ab8-b195-a823051aa608"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4c857c1-be5a-439e-ad52-b9fbecd32f71">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d38fb67-2e5f-4117-90cf-3dcc8ca75d65"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe181282-c089-40df-bd3e-d285705699ed"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_19442c21-7b98-4d93-8859-9516af3b2d86">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ad836a1-1b61-45ac-b299-9c804841a8e2">EV <link linkend="DCM_121030" xrefstyle="select: nopage">(121030, DCM, "Subject ID")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9e5d98b5-18c2-45e4-ae09-6ff8b89e25ec">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d657b7db-3ff7-427b-abed-bebd50372b5f">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f758793-398d-4e9b-9ab3-311ef3907ac8">IF Row 4 is absent</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cfa04a79-a054-4f54-92e8-a37b8593239a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f38cfb2d-8768-4151-a522-c90aaa1049de">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f0604e1-ff53-44f9-8aa1-e12947513420"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5c236b8-07ad-403f-9253-6d4fb0aae96a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fcedd439-57c3-4627-8f54-4ca3eb67b1cc">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5a7105a-bc3c-45fb-8820-e2dc37e6857d">EV <link xl:href="http://loinc.org/11951-1/" xl:show="new">(11951-1, LN, "Fetus ID")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4c13ee0c-4c7b-4453-a8e3-9fd753235d57">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5607a77a-a375-40d5-aa9a-7b00d1499701">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e1dc5b9b-b019-4486-8a6b-3662bd2d6b33">IF Row 3 is absent</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ab7272e-639a-4d7a-b7df-a944261f7f5d"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_887d0f18-b3e6-4050-8184-68dfea692859">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d2ca953c-798b-4759-959b-e6ed017bc438"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a776705-7db5-4e52-8437-f8473cfe4817"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2edac33-2efc-46b7-87fc-394c54e68769">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3d2f04f-9251-4929-b37b-88f07612112f">EV <link xl:href="http://loinc.org/11878-6/" xl:show="new">(11878-6, LN, "Number of Fetuses by US")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fc5a803c-ffbe-4db7-9d78-b65d03b60e04">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_02009084-2eae-47e6-bfdf-ca4d1c670454">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_478a2e28-0ab2-4105-90ad-627e4baaa885">XOR Row 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2cd531a9-4ae0-4c52-ae54-bd04f2103f16">UNITS = EV (1, UCUM, "no units")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_23ef8d7a-e352-427b-94ba-0a1be6279913">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4bb4a7fb-3a1e-434d-9774-b22a45059ddb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_47925746-08f0-40bc-8175-1076709f1e7f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf965469-f6ee-486b-904b-38a5940aa79c">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1d4976a-9f45-4ded-9b3b-d7c7c3d43b92">EV <link xl:href="http://loinc.org/55281-0/" xl:show="new">(55281-0, LN, "Number of Fetuses")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9a2b653c-c2de-4504-a6a0-9d55f445ffc1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_43389d8c-d3fe-4340-8f51-c55b91c51645">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_debf85fa-b733-431c-9b4f-89ad4c4839de">XOR Row 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9e542c7-7e7b-4271-8df8-243ca6a585b4">UNITS = EV (1, UCUM, "no units")</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_24c7757a-e967-43fa-be3f-9dbd42dc8a89">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr>
                            <td align="left" colspan="1">
<para xml:id="para_bfc75ecf-f91e-41eb-aad7-1f809fdcbb1c">Row 2</para>
</td>
                            <td align="left" colspan="1">
<para xml:id="para_0a024645-a3c0-47d6-8eaf-680c4748c26c">For longitudinal tracking of individual fetuses</para>
</td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1">
<para xml:id="para_e207b7c3-16e4-4778-a439-1570ceff1585">Row 3</para>
</td>
                            <td align="left" colspan="1">
<para xml:id="para_c16a2a65-3883-4bdd-aa23-c4a866fd12d6">For longitudinal tracking of individual fetuses (human readable value e.g., "A" or "1")</para>
</td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1">
<para xml:id="para_3bb180a3-2587-4d27-9da8-9c73e1d9f237">Row 4</para>
</td>
                            <td align="left" colspan="1">
<para xml:id="para_906269e1-6936-446e-b32c-a877f921bf36">For separation of multiple fetuses during this procedure e.g., fetus "1" of "2" … not for longitudinal comparisons.; i.e., the "m" of fetus "m" of "n"</para>
</td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c212ea3-6166-4555-aece-47294a98ced2">Rows 5, 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_76a11914-6e18-42f1-ae78-6567d5a3b9d9">The "n" of fetus "m" of "n"; either the code for the ultrasound method (Row 5) or for the non-specific method (Row 6) may be used</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1009" status="3" xml:id="sect_TID_1009">
                <title>Subject Context, Specimen</title>
                <para xml:id="para_d7b1c8a0-f184-4cd8-8a50-46d5f14a349d">Identifies (and optionally describes) a specimen that is the subject.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_e724f4f3-5127-4605-a4fa-53a39b03cad8">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_a5f7f333-ac10-4a2a-8b33-4b9a72066847">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4c145fc4-61c3-46f1-9c25-94b58f67d256">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1009" rules="all" xml:id="table_TID_1009">
                    <caption>Subject Context, Specimen</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b6b259b8-4871-4d61-897a-6d0194519d8e"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ac9509f9-a730-49a5-ae70-756d9417cecf">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_81020764-ef91-42c2-b1f4-33af881aef53">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_17c0d926-19b4-4219-89f6-0224bb0a5778">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1cec0d70-a6db-4e6f-ba36-5c2f6bb23c39">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7c5e2c00-72a1-47ac-bb78-bd2a53375365">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_52846da1-0824-4617-bb41-989601078241">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_77fa9f98-f3e8-4c9a-8266-a26c99f0914a">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ba291949-a169-49b4-872e-c45be17fbd41">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61809b7e-421c-4469-b1cd-93d6e4b776de">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_063e46e8-95b0-4951-827a-8be8be6a575c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b47311f-8789-43a8-b60f-3f78fd04d72d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_40d931b4-d6a7-4aa2-b273-d7af296d9f08">UIDREF</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5542c4f4-1f20-42a0-a504-2fe76858372f">EV <link linkend="DCM_121039" xrefstyle="select: nopage">(121039, DCM, "Specimen UID")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_100db0ff-eef7-47d1-b2e8-0d64342198e1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_11c4d73c-307d-4cdc-90ed-21128d881ea4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7cc6f1cd-eda2-41ed-a980-e4a36be3ea2c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d00d97b8-e3fd-41e6-b590-22738b1ac898"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48855b9e-9889-4215-81c4-bbe89094131c">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b438a64-9f91-43fd-9e54-98f0763b5392"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_944915bc-e4b3-49f0-abb8-634ad9dcbc36"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57b4fd70-16da-4f3c-875f-b437735099e5">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e7b3db6-b6ed-4f31-982f-0a93ad6a738f">D<xref linkend="sect_TID_1007" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_828ec30b-529d-4c51-8dfe-e655fd6efa3a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_15de83f4-387e-408d-b631-4afbd2cf2557">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0c4deaf0-2c29-4ecf-aea9-5cbb87030947">IFF the source of the specimen is a human or animal patient</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa515f09-c567-4349-a14a-b4e55e881e00"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96fc0245-5194-4aa6-afd9-26321e7efd62">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_deaee182-8e74-4241-8987-fd4ce19c1b84"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4186dff-0e9e-4c53-b378-d50295d84d9b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c3461cf-78c9-41b7-8c09-c430fccbc87c">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_215582af-309e-48e8-9a45-6ffca06b9c68">EV <link linkend="DCM_121041" xrefstyle="select: nopage">(121041, DCM, "Specimen Identifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c020f6ee-c9ca-4477-821b-f9cdf2d521b9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_914644cb-c9e5-4001-ad9b-23530e39403e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8650d9f1-88b0-4ae2-bf53-106b722aa1db"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5155c748-c69e-4e65-be1f-20402e98b58b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b8bff61-9357-4911-a671-8d2a93054c3e">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50c9b4ed-04d6-4c47-962f-e4581fac7f5c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_223c73c4-5694-467f-995b-3766b8e9048e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59fd9205-d715-4263-a8e9-3cfd39860e6e">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b50194fb-b16a-4918-9189-cde0e1bafed0">EV <link linkend="DCM_111724" xrefstyle="select: nopage">(111724, DCM, "Issuer of Specimen Identifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b6f3f764-9bfa-43de-b419-db82a60e9133">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7f7c2898-2ae1-4b73-bd64-52c3efa9f206">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42eba740-de38-4e56-ac28-352a76f8a393"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e74351b-aca1-4fd5-a2c8-b7a4a4f56bcc"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b088870-e345-402f-a339-8a369ba1e672">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3fb08b5-0cae-412d-b472-a7b040b7d1b9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_634370ad-3a55-4860-b7c0-90e53f568d18"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e244f4bc-c524-4590-a8b3-ab7a3c5890cb">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09206182-4dde-45bd-b90f-e4c64204566e">EV <link xl:href="http://snomed.info/id/371439000" xl:show="new">(371439000, SCT, "Specimen Type")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_24aa3d54-12b7-4015-ae2e-9d029ba8505f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_32d12023-4be3-499e-8359-1513708d3183">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83bb5cdb-a1f9-4952-a221-0015f957739c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55ca2dae-90cc-4210-92cd-c90402a3fc78">D<xref linkend="sect_CID_8103" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72aec620-d817-432e-9a65-6618cbb697c6">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7d60084-d028-4e81-a83c-c06d1f8b8a52"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f2cd999-17b0-4a88-809c-1569c99ff3c5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf64d11c-8a3c-49cf-9bd0-c8fd0fc11d8e">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_76be9af7-a93b-40ac-89b1-80bc5f68e95d">EV <link linkend="DCM_111700" xrefstyle="select: nopage">(111700, DCM, "Specimen Container Identifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b703caa6-8104-4410-86f3-85c60df0cff3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9d8b57e9-74b5-40ce-bde7-869891c6d8f4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d8a3cc1-f0fc-4526-83b6-7cb422d0d31b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0618c7a6-5cff-4d71-a0dc-13ce656ae8ea"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_6f4d5685-8e1c-4259-8381-f6cf4fef6ab9">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0250628a-f034-4160-b423-b42ea9d5373c">Rows 4, 5, 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5cfb7aa3-0aab-48a1-947e-f02807553ec2">The Issuer of Specimen Identifier shall be formatted in accordance with the HL7 v2 Hierarchic Designator data type (see HL7 v2.6 Section 2.A.33), i.e., [ <emphasis role="italic">Namespace ID</emphasis>]^[ <emphasis role="italic">Universal ID^Universal ID Type</emphasis>]</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1010" status="3" xml:id="sect_TID_1010">
                <title>Subject Context, Device</title>
                <para xml:id="para_968f0c1e-82b8-4fd1-ac11-476762e586ec">Identifies (and optionally describes) a device that is the subject of observations.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_b84b039a-9481-4f8e-8bf2-f4d7bf58f846">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_8d6f1efe-71ef-4018-ba17-86878ef8e769">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_8b027d21-5e93-47ad-a15b-7c4f3b087f2c">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1010" rules="all" xml:id="table_TID_1010">
                    <caption>Subject Context, Device</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5d48a9d5-b4cd-4388-a4ac-20376fc43564"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e252e6c6-5497-4900-af47-fbcb14280cd1">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3c264d01-8416-448f-94b3-4ab66faaea19">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b9a40c78-66f8-41ad-8e20-bfee19cac163">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_df095000-145d-4fe9-8607-0d892c35da8f">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dc62ae5d-e65b-4779-a620-87155bebf3c1">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f2eaf996-480b-4929-b77a-baf13a48d88c">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a66e6b27-c9f4-4ac6-924b-b70a84194a8c">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d948acb8-2f43-4dd7-b1db-3a9ff571b1b8">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d01fb74-2c21-4109-8f5f-3a41b59ad4c4">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd4b94e8-50c2-428e-a59c-fdc013b9ed01"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_33e031fa-440f-4aaf-b1ed-0fc42a41d811"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a05e0487-38ad-4540-ae55-e37ac526160b">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e88c9a8-9f4d-407c-87a5-13be2eb2bb8f">EV <link linkend="DCM_121193" xrefstyle="select: nopage">(121193, DCM, "Device Subject Name")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3936efea-a659-4dbc-af69-372b38fdb068">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0fdfa173-f6a9-42cc-ab6c-3d290f46b932">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7665075-cf0e-493b-9df3-8a11c87097f8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff9b1172-6c9b-4ef3-a048-f08d3fbbdb53"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f7b7f70-135e-4358-a32a-f91313342378">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bfcaa85e-c39a-4c09-b044-004e0d1ff5e5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d9d37fd-ded1-47a6-8b73-4084ada95bc5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_751c6484-d0a2-4cfc-846c-9759863fbda1">UIDREF</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa2efc9a-890d-4c90-90f3-d74bd32d2fe4">EV <link linkend="DCM_121198" xrefstyle="select: nopage">(121198, DCM, "Device Subject UID")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_af83dfd8-ed13-4069-907b-501abcd70402">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_09b32a70-1c67-49fc-9e9b-71f2d81cdda0">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70123bb0-12ef-4691-8825-ad09886e4fc5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df75497f-4e9c-41d9-a448-071d0d5e0591"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_acb48fdf-0a02-4033-b045-4e2591c8cab7">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37b67d4d-c387-4523-b3d5-7492bfa82eae"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df841ee7-d5f6-4948-a47a-a6a489993841"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d241a85-333f-47e9-ad2d-4faa568dd457">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8623d4e4-72da-4b02-ad22-8350fea43673">EV <link linkend="DCM_121194" xrefstyle="select: nopage">(121194, DCM, "Device Subject Manufacturer")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_189a0c54-1866-44bc-b286-0051c8cbf20d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4f4dac90-0c90-48a3-9a56-fca9d4837021">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d2bb1ac-b7e8-4b82-848b-40e7a76e8507"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_753e0bbd-d3ff-44dd-84fb-862386fcdfb7"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ab19d20-075d-444f-bcca-8967d6806671">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_120ffde2-a9df-482c-8f53-4819f8f4736c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c19c18f6-c178-4029-b7be-f8449b7ce299"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_47a323a0-eec6-4ffe-8f7f-914523e32415">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_711bb5c9-e8c8-499b-9a29-89c808cbbc12">EV <link linkend="DCM_121195" xrefstyle="select: nopage">(121195, DCM, "Device Subject Model Name")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b0f0d36-739f-4e1e-a7fa-931673731512">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_597228f4-e87c-48f9-84af-590cf88ac1d0">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef3cea27-6ad3-45ec-8c2f-190fbf06f83c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc85e10c-8509-46de-84b0-7bcc89617bfa"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e4b3a6f-032c-4a5a-881c-ba2746411e49">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cfccb115-a4ff-4f3f-9d3a-578f214f3153"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4685d31d-6514-45a5-b1e2-c8585f48a1f3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c40969e1-dd44-401a-bc3d-214a34bbf931">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29734c20-fe54-4c8b-b64e-f0f67dba77e4">EV <link linkend="DCM_121196" xrefstyle="select: nopage">(121196, DCM, "Device Subject Serial Number")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_931e2183-2aa5-4eac-9352-bba7aa7496dc">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_503d5b54-aaa9-4fc5-bca9-6ea2986e5083">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f67f65ff-c358-446b-b439-420d6123de1d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c977517-fe13-4f48-a9f8-75d85a8f5339"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b50553e8-da58-47aa-a0ba-869ba6854abf">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_20ebd839-0cab-4c06-a278-36694b5dec35"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_44610c8e-f3f8-42dc-a047-6762ba152164"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0a94d96-bba5-48e9-a05b-1f78df44dc57">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d89c7e7c-8ac0-4045-aabf-65fd494c4f76">EV <link linkend="DCM_121197" xrefstyle="select: nopage">(121197, DCM, "Device Subject Physical Location during observation")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e1e85f2d-b418-4059-8c94-63af81451ab6">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85e97d0e-eb41-4d99-b29d-9eaed26971e5">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_496f9d08-4961-4c5b-a0b8-59c63380c73e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_959a0108-e59c-479d-b1c6-c44defff238c"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 1015" status="3" xml:id="sect_TID_1015">
                <title>Person Observer Description</title>
                <para xml:id="para_7121f11e-8209-4a73-a13d-a232f38603fd">This Template includes attributes describing the qualifications of the person observer relevant to the content generated by the observer.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_148664ed-7418-40a2-8f99-33bb440d14fd">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ce65ac0f-2ab2-4c4f-958a-0d219a559a7f">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_e31670f0-0448-4c29-b9a7-0c3d0b3d2bca">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1015" rules="all" xml:id="table_TID_1015">
                    <caption>Person Observer Description</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f565c797-1821-45a1-ba5a-b064ba4f6978"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a20fa2d6-9cd3-4043-b963-9e728774972e">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_64f644d4-01cb-45e7-91e8-8d97c5ff0a09">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b4df0ef5-321b-470e-b09f-216e8ef363bf">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_064ac4e2-1842-4abd-aa85-8983fc7fe22f">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e2451d05-b438-4562-9d7a-e215332c7d6d">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ed98fb71-1fbd-43f8-a790-9d956f4da3c0">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cdde81cf-0141-4229-8673-29008556fffd">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_63f0211d-9367-4b6b-b5b7-db57f444b514">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bfcb7ccd-6a43-4417-bf9a-d44c2b73d250">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5597c47-d0fa-4bc4-97e0-10cbd6b2762b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b82f3c6f-879e-4a89-bce7-d1bcddcb91b0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_01da3218-bddc-4689-b1bb-07e48b65912e">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f9093dd-6a27-4397-9d84-02aa01e02b08">EV <link linkend="DCM_128003" xrefstyle="select: nopage">(128003, DCM, "Reader Specialty")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e50316a9-9a3d-4469-b96f-1f9734a9f459">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_451f99bd-b80a-45d8-bddd-04ccc72b6bc0">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05fedce1-ed69-4dc9-ad2b-4b0d759bcd35"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0305a769-cd71-4634-88dd-223b598c3dcd">D<xref linkend="sect_CID_7449" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e46d9bd9-2094-4236-9892-973d2f95ee70">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d2932ae-1d20-4277-92b5-9633524aa887">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0e12650-39bf-4e97-b850-ea02ce4a7102">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f7e4bf89-b119-4873-98a1-6b615834b2c6">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_454ca70d-e253-4159-8bd7-228c2877a9f9">EV <link xl:href="http://evsexplore.semantics.cancer.gov/evsexplore/concept/ncit/C54627" xl:show="new">(C54627, NCIt, "Experience")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_27b9fb91-6c02-4684-8fd0-9c5d7f6e06fd">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8fefaf57-7d03-4abe-b860-f8abfcacbeb7">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5456d1d-cd34-4a93-be60-7b62df4b75dc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35156c1a-deb0-4e6d-aeff-ec0f21ce6dab">UNITS = EV (a, UCUM, "Year")</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 1020" status="3" xml:id="sect_TID_1020">
                <title>Person Participant</title>
                <para xml:id="para_ad13fdbb-33d7-47a7-9517-4f295fd4fcdf">This Template describes a person participating in an activity as other than an observer or subject. E.g., for a dose report documenting an irradiating procedure, participants include the person administering the irradiation and the person authorizing the irradiation.</para>
                <para xml:id="para_e5f3625d-0cde-4783-9846-ee7b2ebf78a8">This Template is included with specific contextual parameters from a parent Template.</para>
                <table frame="box" label="TID 1020" rules="all" xml:id="table_TID_1020_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bb59cf82-7e60-4357-8f92-3d17cb8f23d8">Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5684f860-81aa-4352-b5d7-9e3889a75df4">Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1bc5c4b7-d9dc-448c-b2c3-fc11856791b7">$PersonProcedureRole</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9f50ccc-68ce-42cf-b8a6-9fe3bf15a9d3">Coded term or Context Group for the Concept Name that describes the nature of the person's participation in this procedure.</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_180c0d37-4f00-4359-bea9-d7148cb10936">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_cae29db8-783b-4bc5-a064-aa2b156ca6aa">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_d73f934c-f71f-4975-94a6-cb6aa81f27e0">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1020" rules="all" xml:id="table_TID_1020">
                    <caption>Person Participant</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7b83cc34-f2c3-4ad3-968a-8ea49dda06f5"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bcf31a0c-ded3-4636-baeb-887618c8d93f">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b537bdc1-f12c-45c8-87f6-ff5ed82d930c">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9a0c9ba7-10df-45d2-8fa7-e035796f6b42">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f8d7bb14-cad6-4467-b8bd-df6079bd20df">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_df3dfff7-30c5-4779-957f-3b771d89e412">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_49bae111-63a9-40cd-acbe-5d48c8ed6f60">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d540c707-e3f9-451e-b389-1d732dd2ec03">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_df374f0c-da18-436a-90d3-655101710726">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cde5d229-89c9-41b0-bacc-5085aa2783f3">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ab4a7c5-72b8-4be3-9418-0d3771b66445"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a7b03bb-c675-44bb-8eaa-5f26ae5c5b55"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f69a9ff7-b3c3-4619-b64b-8faabcfcc52b">PNAME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de21d2a3-ebb2-4e05-97ea-2740a7d54d00">EV <link linkend="DCM_113870" xrefstyle="select: nopage">(113870, DCM, "Person Name")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2901fd39-7c27-47c6-b001-63509112c859">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9acb27f8-c583-45f5-8b6c-ed743a1efc1b">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69a2f1fb-735f-4ba2-8d85-b6d31cfb5bf3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6982e46-3ddc-4381-81ed-bf21973a062b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc8adaa3-2797-41cb-bb06-88812a9e3a4a">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d3f7386-fbe4-4cc7-84e5-da8d6957649f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_47281a5e-857c-441c-92e3-6125c29ca557">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_95945eb5-76c4-4b42-9606-0bfa2f547d47">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3f53a65-9052-4844-851f-c72b949658e1">EV <link linkend="DCM_113875" xrefstyle="select: nopage">(113875, DCM, "Person Role in Procedure")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c0dd12aa-e0ff-4e42-b123-b7792b50570f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_60f5ac1a-afeb-4578-ae60-b8b0dfff0de5">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bddbe45f-e542-42c4-8be5-db3b05a92660"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f3f9c9f-abfc-4c2c-b462-78626e6f6699">$PersonProcedureRole</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9db1e6d1-950b-44a7-915b-e787c9543339">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1966c43f-8fc8-4d88-b456-a62a85a9d79d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5ba8b6d-3432-441b-a034-74873ed68f12">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4595b53-9e7b-47c0-a7a6-5455525d6633">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43ad5bc5-d00d-4e36-a82b-2bdf04da9603">EV <link linkend="DCM_113871" xrefstyle="select: nopage">(113871, DCM, "Person ID")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ca95ed0f-a0cc-47bc-914d-6993341a6c0c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b060986e-fdb4-4247-b2f3-7a9b30e54bad">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a2f97f4-7b49-4590-a5de-2b86578fbe43"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9645e71-a534-4210-be72-99ce13cf33c7"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e0e992e-abc2-4615-8148-ce209fc9cac8">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3dc2a75f-5ab0-497f-94c3-8656fa6803a9">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae2ab648-4ebf-4664-a2f4-ecd739f118d6">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b281710c-1dac-46d4-ba93-34da721b3036">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c47e3318-40b2-4b11-9521-efd338f903b4">EV <link linkend="DCM_113872" xrefstyle="select: nopage">(113872, DCM, "Person ID Issuer")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3bf95b0a-4020-488d-806e-0f437709766a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_30f220c8-245f-41a8-bd25-1b08f1c02393">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ae7b4c5-5513-4241-9833-09dadda5581a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e44e4c7-e244-4790-82d2-e3faafc45891"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5ea5042-61c6-465d-9ad9-d0113e39facf">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa44e3ed-6f29-4dab-a576-ef25e46b56cc">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cfc28628-38f4-4b1b-afe1-da7a5ecc06d1">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b612e98b-636f-4028-b2fa-094d91b0e999">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a8dbc91-d83e-4f82-a70a-e4c86d18db8d">EV <link linkend="DCM_113873" xrefstyle="select: nopage">(113873, DCM, "Organization Name")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_37f6ccd3-c7d3-47ce-acd6-c6f0341abdd3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fcab1f10-ec58-4b91-b79d-194f27423990">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_582d27a2-6253-42fb-a4cf-e6559c71a9aa"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_adfa3ccb-3f1a-4a65-a0be-4227ed786210"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b343e73f-216d-4e32-b093-f444aa7a5e71">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f665f86-2286-4253-b70a-755e477b9c1c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ef66940-a2c0-49bd-a64d-36f2bea7f05d">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_060ec65e-f35a-48b8-8306-360387a384b9">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f571708c-92da-42d8-b7de-f0004c3b5d57">EV <link linkend="DCM_113874" xrefstyle="select: nopage">(113874, DCM, "Person Role in Organization")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b5f2ddb-75a5-4394-8b11-92e4fe0094ad">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_84a31c5a-1651-4a49-82e4-e3febb53efae">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e90b6c97-0084-4c60-9e7d-cfd7e76c863b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f32fabe9-8fb8-41c9-b2aa-4c0d7fa3f2b4">B<xref linkend="sect_CID_7452" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_118db7a5-9be3-4874-8c3c-a21799f4ddcd">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf4fd184-0869-4648-a8b3-6b2e170deef4">Row 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_604760aa-7dd1-4660-8350-aa957870cd34">The name of the person participating in the role identified in Row 2.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_048a4ec7-ae35-4506-88a9-97f08be1d267">Row 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6fc5d9c5-5106-49d8-ab96-8dc3fcffae07">The procedural role played by the person in this procedure.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c3ebaa3-4c55-485a-9c2c-c0e8bf6504c7">Row 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6db88fad-45f0-46dd-9814-62d40c678f0a">The organizational role played by the person in the organization.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1021" status="3" xml:id="sect_TID_1021">
                <title>Device Participant</title>
                <para xml:id="para_1c761142-9685-47fa-baae-1023baea4ac3">This Template describes a device participating in an activity as other than an observer or subject. E.g., for a dose report documenting an irradiating procedure, participants include the irradiating device.</para>
                <para xml:id="para_402d2736-0d63-4599-82d6-616c7ae73c6e">This Template is included with specific contextual parameters from a parent Template.</para>
                <table frame="box" label="TID 1021" rules="all" xml:id="table_TID_1021_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ab2946f2-80dd-4416-9634-98c68298147f">Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_df40ba24-2f82-407c-a4b7-0fd0bd5fe73c">Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35c6669e-b008-4b8e-b02f-d8ccbede1b3b">$DeviceProcedureRole</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d982227-0e93-4959-aa1f-fdb19fe72629">Coded term or Context Group for the Concept Name that describes the nature of the device's participation in this procedure.</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_40d05983-92bd-4c33-8c8a-1e3b6c225eae">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_51494265-3556-4563-a824-9b136fd1a4b1">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ea9a6720-cb4c-4924-97f7-1e992e2bca3f">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1021" rules="all" xml:id="table_TID_1021">
                    <caption>Device Participant</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_44a90e16-171b-40cb-a373-83bcc2d94cfa"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b5271c3d-fe58-4870-91d1-bb6ecb942828">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f1c1e83a-6b83-497c-8de1-aace5600724e">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_51b0cda4-290c-4043-8e62-d93855ed261c">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7a611db3-d8d3-4b5c-b195-a0dc0b15891b">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_676d69fd-8b28-4b1a-beae-614b58cc5d6e">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f2393842-bdd0-43f3-a231-a6516bd95521">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2b7c75c2-1de1-4287-8e1f-262685d786a4">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b65a47c7-c270-47fb-8e23-e57bc73f0b8f">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a42ba0ff-ad59-47d3-b6a5-447ec1771c14">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe50534b-96bb-42cc-b6fc-91f53c5b37a0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa0beb42-0196-4976-be7e-18b60fdfd40a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62586244-ef13-4f29-86f0-95162d618fee">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e884b66-e699-4161-9cc9-e4ad637d11eb">EV <link linkend="DCM_113876" xrefstyle="select: nopage">(113876, DCM, "Device Role in Procedure")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2149c4e5-5a5e-4b7a-a0b4-b532d46efc42">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c8612938-df5d-42aa-9540-3c856b3f46fd">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f7a541d8-3beb-4f15-8418-f7deff11d20e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7cbe39c3-5183-4c52-aeb1-e6157e6a50d5">$DeviceProcedureRole</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec62e66d-b143-43d7-a46a-69b2381d88ee">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_374746bc-e404-40da-9dd9-1e7ea6c5f507">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86f75423-dfcc-4459-b626-7820953be59e">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ebc01b3-da9c-40e6-8f3c-56b110e86d4c">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81d76494-5ff0-46b1-9adc-1baa86e76b9a">EV <link linkend="DCM_113877" xrefstyle="select: nopage">(113877, DCM, "Device Name")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ad4d2324-ae52-49ba-9f89-83b81a0dc7b1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ba74da66-b67d-46dd-8353-8648b072a830">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7a2a5e16-9e13-4e01-9469-28d1e965f7a9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa4adb05-e12d-4150-a00a-2ed8393c219d"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8aac2685-ce4d-49a0-81c6-c90c9ec0048c">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f6070bc-7735-4ac7-afc0-55d37342cfeb">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_14faa315-be86-4a16-84e7-5127e290d2c7">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc8475e6-a410-446e-b616-4ce29ed59d7a">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_291b058e-aeb6-4522-948a-e3c804e1bc85">EV <link linkend="DCM_113878" xrefstyle="select: nopage">(113878, DCM, "Device Manufacturer")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0fce0266-838a-44a7-891e-adf10d091458">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_16fee0ac-2cd2-42cf-bd5c-6504559ff14c">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6cdb4fd8-ba67-4536-b586-6bf4e7b484d7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cfe94021-c4c4-4be4-814d-87acf6088686"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_857a96b5-e8f4-4232-a8cf-b783c6ccf607">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46aabf86-b6b9-456c-b5a5-e3da726dd634">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ee8a3d8-9575-496a-8e32-b6f4c306b7ec">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11c7f6e8-b108-49ce-a71f-687b55e59b7d">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d2384e7d-f2a9-45c4-8798-42f507fd65ef">EV <link linkend="DCM_113879" xrefstyle="select: nopage">(113879, DCM, "Device Model Name")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3d7426e3-7d31-48a8-985f-d269b1f03e83">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7d44800f-aeb7-41f5-89e3-e855a0039a2a">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6c672b2-7d7b-45c3-91ee-f460d8d2fb7c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0af8203c-a78b-4e68-aaa4-3811a3d4e3e6"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_139bfc01-60f7-4198-8029-8431bfbea5cc">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8decaa0c-ffed-4d55-9d4a-72b35d5a4bbd">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92948d25-de8a-4581-9c18-8a1734884aa4">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_28debbb3-0f02-48f9-88b8-f7732315502e">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd84e825-62f1-477a-8cf5-153a80c125c7">EV <link linkend="DCM_113880" xrefstyle="select: nopage">(113880, DCM, "Device Serial Number")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_418b3e2b-bcea-4101-a9d4-c44b0c007828">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e3f08c30-a564-4a33-a6da-882d20b350db">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3bf3c015-5218-4d1c-84fa-013ff7d720c3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cda09ea5-d665-419e-ba18-74707a2b4202"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a4a6de1-ce3b-43db-9f18-75c02cca35c4">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7a7c074e-df57-43ef-9f77-a7cb407cb674">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b25b4d7f-6885-4f36-9137-46f60d3e9cc9">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8eb1866b-ac91-4b1d-a566-a1f046311ba7">UIDREF</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1be3801d-a69f-4656-9ded-da3e8ffb1166">EV <link linkend="DCM_121012" xrefstyle="select: nopage">(121012, DCM, "Device Observer UID")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f3620f66-30ff-4915-9e9f-f10a090380f0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_68085d33-4743-4fb6-aa2e-bdf2cc5f6059">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a0ebcfc-dc3f-4177-a73a-06b387735b1d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f387208-276d-4f5f-8522-ef95bd029aec"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_45cc454c-df8a-4b8c-ab04-1362dd977d66">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e34a046-7718-4d0d-9bb0-484dba2f68d2">Row 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b9ad578b-6585-4b21-99e3-d7d7730879fb">If no Device Procedure Role is provided, B<xref linkend="sect_CID_7445" xrefstyle="select: labelnumber quotedtitle"/> may be used.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_583b9d1e-94c7-4f4d-b30a-5adb55593567">Row 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a53fa24a-87d8-4999-beda-c18482c908c2">This may be used for the name by which the organization manages the device.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1025" status="3" xml:id="sect_TID_1025">
                <title>Indications for Procedure</title>
                <table frame="box" label="TID 1025" rules="all" xml:id="table_TID_1025_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_00810c80-b22a-4fc1-994a-091891b29636">Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fbe8f683-b317-48c9-a4df-1d9421b81633">Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88d1a506-896d-4551-924b-12f527907947">$Findings</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e100d492-c68a-492d-b77b-3abcdc2c40a2">Coded term or Context Group for Finding.</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_3d1703bd-974b-4a71-8115-b051669358f5">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_7a77701b-e387-45d0-aae6-03c3201dd088">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_bfcbad52-bfc0-491a-bdd8-075a53c986ee">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1025" rules="all" xml:id="table_TID_1025">
                    <caption>Indications for Procedure</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_44cf970a-6a3d-4de2-8c44-95033c11a4c5"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_114556cb-72a0-4cb1-bccd-251558f76653">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fc7fcaa8-f0e7-409d-be25-749ad4ca2bda">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_90a67e53-8f29-489f-bf4e-e6595a65925d">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_802a380c-79cb-4e5c-81e1-4c09eaeef1a1">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7f05da6c-19e7-4a51-9556-5491f854177d">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_19e42035-35d6-4abf-b634-06d85fee26f9">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_689fedc4-d63d-4fab-91e9-36fa2b15c280">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a3d89ffd-9dde-4d81-a10a-709d88f2ab87">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d47e141b-542b-4427-8ef8-909666b4aeca">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0860878f-3dc0-44ba-820f-9f7ca456b0ed"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eeb53068-eb68-439d-b46a-73c62704f972">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4504b3ef-9376-481b-a790-c3a5adf0c02b">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ffa6e987-fc08-43c3-ad75-00edbe4839e3">EV <link xl:href="http://loinc.org/18785-6/" xl:show="new">(18785-6, LN, "Indications for Procedure")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_55fee6e5-c783-42f5-8df0-fdb843fa654d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_77b888e2-a702-4a49-bd1b-0caf90c7f18f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d1ce58b-fc88-4fe1-a6b9-1c3401318f42"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7edb19bf-fe73-4959-a2f6-a6222710932f"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9bed6965-05aa-403e-9a2e-671fc2343034">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0aaba273-a03d-47c9-ae90-80dc2eb83707">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e96b347-c2ca-431e-873f-b235d7b46d89">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f28bf14-6aee-4d93-9cde-3dd2327ee9b3">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80e9b599-68fb-43c0-b3ff-a8dc0427aa7c">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cd458c02-87ad-4acf-97b0-12a39939b198">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_27e37269-55bb-4dc9-83da-43efaf4ef883">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c69329b2-e380-4b80-bb92-d36905e5e421"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82182e40-f225-4bbc-90d3-43ed1e3e80d6">$Findings</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6d9e5b5-2ba7-4a51-a405-af34a6316f8b">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4fc3a172-a34d-4fee-95e9-6bb818bcc376">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d4e7d03c-0f18-45ee-b1f6-7ff561c7ef59">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d11912f4-459c-495e-8d5f-6bb333f9626f">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f88a6b47-ef12-4a06-a14e-bed120fc2cf7">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b8002818-ff1a-4fcc-8365-e8611808eaf6">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cd92003d-56d6-44a1-91cf-c897d94ea3ac">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3fa302b5-bc7f-4cff-a634-c7ae08a2d1cd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_18b9eb20-7869-4423-9d82-72dc8b99b878"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 1200" status="3" xml:id="sect_TID_1200">
                <title>Language Designation</title>
                <para xml:id="para_8088ab54-3e25-4476-b295-f2457c423d1f">Defines a mechanism for specifying a language, optionally with designation of the country in which that language applies.</para>
                <note>
                    <orderedlist>
                        <listitem>
                            <para xml:id="para_437ee6d0-f26f-4fad-bd85-17dad2ad32bd">For example, the French language could be specified unmodified, or French as written in France or Canada could be distinguished.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_e47af2c6-ac04-41db-9ea6-7559019fe7ea">The language codes specified in <xref linkend="sect_CID_5000" xrefstyle="select: labelnumber quotedtitle nopage"/> optionally allow the encoding of the country of language in the Code Value for the language. Encoding of the country of language in a separate subsidiary Concept Modifier Content Item is allowed for backward compatibility with previous releases of the Standard.</para>
                        </listitem>
                    </orderedlist>
                </note>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_3bbee009-81a0-4652-9631-dda7423a30de">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f0360d43-2140-4c72-a308-0f6e50ee49ae">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_0df084af-1405-43dd-9cf0-afb81e8aafde">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1200" rules="all" xml:id="table_TID_1200">
                    <caption>Language Designation</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cfe6354d-edca-4e39-b5c5-9540214bf33a"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_38e6fa51-8dfe-479b-b347-a6f51eb5e81b">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_02a2d716-82d4-401a-baef-174ad62a1e09">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_329aacdb-53e7-4ae1-a8ab-7d56a9dc6f9a">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dbc9b9ed-db5f-4506-b759-0aecb4785ec0">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b84613e9-5bfc-4170-9d9c-cb0cc8c002fa">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_13169718-adb5-443e-b0c0-7b5a34d93336">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b1b89686-179a-4a4a-9200-c0d02239f4bb">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f6ba1ac-9222-437c-acf0-e6bed329a5bf">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa25dbac-40b2-4670-8792-5bc4fa054b6e">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9cf5f42-d421-4123-a665-0f3b11b59e58"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e0e2808-b430-41cc-a534-6035c5c1aafa"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7eb0d9cb-457c-43e6-b6b5-10fe68c2d33b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec346369-7a6a-4890-9ab1-cd2282ed3903">EV <link linkend="DCM_121045" xrefstyle="select: nopage">(121045, DCM, "Language")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b0ed5e28-e09c-432b-a92e-0b422a1c5ed2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_32d2ace6-4366-4b74-82a6-91ec651ac905">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42392ac2-ed42-46a5-9cc8-af5de8e43579"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_56db8e16-5488-4cfa-9b9d-77af25f11658">D<xref linkend="sect_CID_5000" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f7b997a-4b80-4fd4-8dc2-355636bacf78">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_db77ca39-56df-4ec2-86dd-e8a2a93796fc">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3b6a5e1-5d84-4bb4-bc2f-a1a673aa6327">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9140c77d-3a86-4f01-9ef4-2892cb55a365">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5104f78-29ec-41ed-9124-5eed3d71f384">EV <link linkend="DCM_121046" xrefstyle="select: nopage">(121046, DCM, "Country of Language")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a47a48f9-5ae4-43c1-8ee2-ae0d1648543a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8af55770-19b7-445c-8b07-4fcf4a5c7ca2">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6791aa5-a5e6-42bc-9f89-f35f388a34af"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02d0f3cb-57f7-4d8f-8fe0-57ffc7481e09">D<xref linkend="sect_CID_5001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 1201" status="3" xml:id="sect_TID_1201">
                <title>Language of Value</title>
                <para xml:id="para_437cf61c-aef7-4906-aa35-5fa43a4f82c6">Defines a mechanism for specifying the language in which the value of the parent Content Item (only) is written. Does not specify the language of the Concept Name of the parent Content Item, nor of any other descendants of the parent Content Item.</para>
                <note>
                    <para xml:id="para_97ac1fd1-654f-4c4c-98b8-c09a28e76c9a">The language codes specified in <xref linkend="sect_CID_5000" xrefstyle="select: labelnumber quotedtitle nopage"/> optionally allow the encoding of the country of language in the Code Value for the language. Encoding of the country of language in a separate subsidiary Concept Modifier Content Item is allowed for backward compatibility with previous releases of the Standard.</para>
                </note>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f0731a37-a965-46de-9d72-c145a903ac47">
                                <emphasis role="bold">Non-Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f4d89abd-56b8-45fa-9041-8f34ca4d5d3d">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_db86cc02-f808-4061-94d9-d1ad27785b7b">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1201" rules="all" xml:id="table_TID_1201">
                    <caption>Language of Value</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8391644d-5537-4e07-9cb6-512a24f21d85"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9d4e15b1-d6f8-41bf-92ec-ca7c32ee4bca">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2f255af9-cae7-40e0-abdd-4f2431e9afb2">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4ea8f3d0-ff67-4394-a948-c607eb50d5ed">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_65881fb5-fa0b-406a-a846-239f83a5cc2c">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dce26593-9b12-45ed-b152-7a622ef8aa52">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5ca609c7-f225-48b2-8d0e-61d61cb4e7e0">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c58af4b3-c849-4d75-8cad-a2f145523c77">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ed419ad-1e61-471d-acb3-3eea78d98c58">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_629025df-5cae-4c8f-aacb-6fa51a4a9668">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a8a1897-1b08-40a2-b44c-dab0b077787a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0d7de19-b8c4-4a9d-85d1-4c561acc7abe">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b9c0f23-2828-4e1e-9451-ae41fad4a25e">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fbdaaa18-a8af-4deb-a2ed-4b03e10e4f01">EV <link linkend="DCM_121047" xrefstyle="select: nopage">(121047, DCM, "Language of Value")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_da2cca89-f03d-475b-9c89-caef9b2b0b40">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a0ab75d1-27d3-466b-ac05-46180286f90b">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6cdca3ea-4646-46c0-8b19-e30cf8f748e3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ec64d78-4d7a-4db1-9d80-70d8f8430ed3">D<xref linkend="sect_CID_5000" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22e3cfed-3c5e-410a-811d-34dd3bd49545">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ed9f506-e7dc-43d5-b48d-6775758dba75">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c9276b09-7448-4016-8a88-90b539c1c2d2">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_367eb99b-723e-424d-9559-9059229ac7d8">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae276ad3-15f6-43f2-8f75-3b359b60627e">EV <link linkend="DCM_121046" xrefstyle="select: nopage">(121046, DCM, "Country of Language")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_752cdf55-0797-41c6-9dc2-0fdf1ff243ac">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9db14f09-ab0d-4ef6-a1a8-0ea8fccefd57">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75e52f36-fc6b-4e95-8cdb-1848ed983036"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0dac01b-4d9d-4bc3-9782-c4fcb7ee64c6">D<xref linkend="sect_CID_5001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 1202" status="3" xml:id="sect_TID_1202">
                <title>Language of Name and Value</title>
                <para xml:id="para_209909f1-a133-4350-9823-145ad8c18baa">Defines a mechanism for specifying the language in which the value and the Concept Name of the parent Content Item (only) is written. Does not specify the language of any other descendants of the parent Content Item.</para>
                <note>
                    <para xml:id="para_e4d44d83-af77-4c46-9214-3b9a7c4ce00d">The language codes specified in <xref linkend="sect_CID_5000" xrefstyle="select: labelnumber quotedtitle nopage"/> optionally allow the encoding of the country of language in the Code Value for the language. Encoding of the country of language in a separate subsidiary Concept Modifier Content Item is allowed for backward compatibility with previous releases of the Standard.</para>
                </note>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4b38b7d8-9408-4558-a701-735efb493b63">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_54ebed4c-c66a-4f48-a6fc-ab26177b2a05">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_2e95c391-dd1d-4d46-8eaa-770501ef98a2">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1202" rules="all" xml:id="table_TID_1202">
                    <caption>Language of Name and Value</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6eb8ccea-4001-4e19-ab97-1e50c84c81dc"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e972efe6-f834-4c4f-8ae4-1b5162e72e2e">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6dc0cd9f-95fd-4111-8e05-0ac99f6e4bc0">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_76382056-e955-4c3a-a2bb-0c24c2e2141f">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c052cb4c-ea95-44cf-98c5-8c6254f87afa">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f7aa2824-a9c2-422e-bc7f-c40fa06213bb">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb934e0e-5c7a-468f-921b-81577ca23660">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9ca3d6e2-c4e0-4fd8-a092-26707a0d5cf2">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2b3eca1b-c80d-4865-bfb7-48d2ecf1c587">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_19507d6c-fef9-494f-91c6-9a2621c3a221">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_71ca8681-6234-4147-9b5a-8dd8d708b8f6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98c2de35-6747-421e-9de5-088ecc6f5444">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a73d8bc3-b10e-4506-aa3a-daa8fd735061">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e982890-0c64-42de-bf56-35e884ad68da">EV <link linkend="DCM_121048" xrefstyle="select: nopage">(121048, DCM, "Language of Name and Value")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ffbbcfe3-e290-4cb4-8372-362ffcebc211">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_009e78f6-7924-428f-9870-a772e529ce44">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d262a32-9f40-4b11-b47a-29a27b2f816e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b96fc49-8dad-4ac0-b451-50012dac350e">D<xref linkend="sect_CID_5000" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dcf5aa51-f3cf-4c95-9a40-666c81240703">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ed6ca0d-d7c7-40dd-ac6a-2b8d103352b4">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_44beca2e-8ee9-4ad2-9c95-098fcd85023f">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1c488a8-c8c8-4f6a-abce-0fc4d5e2b2e0">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf16e471-bb0f-4ee7-b7cf-a487a7e3c6ea">EV <link linkend="DCM_121046" xrefstyle="select: nopage">(121046, DCM, "Country of Language")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1769dbaf-a45d-4e67-a3b2-1fd0aa69ac53">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_92ec1c2f-5e32-48e5-a209-18679432b9a4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d6f57969-7437-4fea-87c4-47b5d2683517"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc3761f2-f72c-4b39-a016-c9a140d04ca2">D<xref linkend="sect_CID_5001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 1204" status="3" xml:id="sect_TID_1204">
                <title>Language of Content Item and Descendants</title>
                <para xml:id="para_5383742b-cc4c-4a4d-a0cb-f8483c7cc90a">Defines a mechanism for specifying the language in which the value and the Concept Name of the parent Content Item and any other descendants of the parent Content Item is written.</para>
                <note>
                    <para xml:id="para_0c53c217-16a1-4df5-962e-57b25ee58a2e">The language codes specified in <xref linkend="sect_CID_5000" xrefstyle="select: labelnumber quotedtitle nopage"/> optionally allow the encoding of the country of language in the Code Value for the language. Encoding of the country of language in a separate subsidiary Concept Modifier Content Item is allowed for backward compatibility with previous releases of the Standard.</para>
                </note>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_81c26780-c5f2-4514-a6bb-5509aaf39141">
                                <emphasis role="bold">Non-Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_1e8d4541-1a3a-49d2-9dd6-70e3381901ab">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_d34d3bb6-f7fa-45cc-a99b-dd15014a75b0">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1204" rules="all" xml:id="table_TID_1204">
                    <caption>Language of Content Item and Descendants</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_611638ce-c881-4d3c-b080-e7c11706d507"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_416de455-0cf3-4c46-a109-46d017b07619">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ca50250b-b3e6-4d04-bae0-60bbaf4619df">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0af7bd8f-e8f4-45c8-8548-96bbd461efd6">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_37c9a2c8-6a16-47bc-9342-405c5a60ae37">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ce4c434f-a525-4929-9226-7b37049b9e49">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_09129577-d354-45aa-b0f4-0c978591ff55">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b0b508ee-07fc-42b8-8f89-4860f82edd84">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_14751ee9-c0bf-4ac5-97b0-cf80fe84d737">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df443627-95ea-4adc-ae63-e7ad179eb520">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04a04443-ad2f-4cf6-b626-9f552ced2768"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e59c3d64-2b8d-412c-84d0-ee1a9c3812a6">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16edeb1c-d94a-41e7-99dd-57c0859af568">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f64e0f4-43be-40c4-bf44-a3f8a0566bbe">EV <link linkend="DCM_121049" xrefstyle="select: nopage">(121049, DCM, "Language of Content Item and Descendants")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b475906b-ecfd-4437-a2b3-36a260dd7796">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73b3fc43-d4a7-4980-a0fc-2993dfc4edd5">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6305d57-746a-4775-a622-bed632d02847"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd8245bd-d484-4c7b-8d83-82186d72d296">D<xref linkend="sect_CID_5000" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_12874d11-631c-48a2-ae3d-8882861b3f2b">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50704518-b1b1-42dd-b9fc-f4387b0087ba">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9dcb18fa-2798-46c4-8325-46b038e9c0ed">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6002168f-70e9-49df-953a-9d4e9f982740">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0a3d411-7510-47cb-b925-5578a351dea8">EV <link linkend="DCM_121046" xrefstyle="select: nopage">(121046, DCM, "Country of Language")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_35b3c2cb-fadb-4ef7-b5af-1509ab2b1867">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b3ae5efc-6f60-4358-a8f9-a67e28d97432">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84981529-02d0-4c7b-a8eb-df883c741523"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c07ccbd-a694-4e6e-9d8f-359eb6afae42">D<xref linkend="sect_CID_5001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 1210" status="3" xml:id="sect_TID_1210">
                <title>Equivalent Meaning(s) of Concept Name</title>
                <para xml:id="para_67460666-1610-4bbe-a20f-b22836299e28">Defines a mechanism for specifying one or more equivalent meanings for the Concept Name of the parent Content Item.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f8a27d51-558f-4b9c-b5e9-f597a90833e3">
                                <emphasis role="bold">Non-Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4a972f78-f8fc-454b-9233-6a54b7d5aa6b">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_269e8bab-22e0-415d-aaf6-7d3a69277796">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1210" rules="all" xml:id="table_TID_1210">
                    <caption>Equivalent Meaning(s) of Concept Name</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2cc9c6ae-f907-4032-af2b-6e2e45ee59c4"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3b162d37-3715-4547-b241-ff17a2c34c18">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_55396032-55e4-45f6-944e-e2f432538e2d">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c6e40b18-aa7a-4e8c-aeff-ae03ad81b61b">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e9fcb049-64da-4891-829b-86600dfedc57">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_61adb00a-861a-4378-9486-a859135ba31c">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3f0d0851-1d37-4276-8e3e-af6e094322a0">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ce31f463-867c-4839-86f7-cb5b392542dd">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6df28d1c-ac1b-4faa-9ec9-52b987747563">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_953583ac-871c-4bf7-9830-b3004a9246c5">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2bfa81a5-8459-40f0-a8e8-c53f0f3c4906"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43b193cc-fc14-4c66-943e-4c3367df023a">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58e24f31-4c5f-4a1e-8355-3210d948ba2d">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_764ecab1-f69c-44de-b721-275e39a4e258">EV <link linkend="DCM_121050" xrefstyle="select: nopage">(121050, DCM, "Equivalent Meaning of Concept Name")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a32f6b46-e1a1-469d-839b-b2e1d51330c1">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_58c8825c-20c3-4170-ab3d-0601af49ff7c">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f3b8510-3810-4fbf-8bf4-3c5f7c5f0b3f">XOR Row 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b57a324-38f0-4508-bd54-93661640971e">Plain text equivalent of code meaning of the concept name of the Content Item being modified, in the specified language from the specified country, using the default character set or a character set selected from Specified Character Set</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d43faee3-70c1-45b0-906b-4302672bbe6e">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98a51c05-b98c-46c9-94d2-a438b7faeb11">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06138b09-aac0-44bc-afc0-b54f76087a75"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37fb35ab-61c4-4f32-b2f8-6fe3491d3ee0">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f1f41c3-b776-429e-a7e0-818bfd482975">D<xref linkend="sect_TID_1201" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_50450d78-c469-4420-a251-bd90cca8a7d0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d81037b4-5d96-4f05-bee0-9ca45384f7e5">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d10a3ed-2d62-44a2-ba88-46792d969842"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8a5aa85-0247-41c5-9db8-a642591a3f29"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ff823eb-0bbe-4262-ad80-c332e44b085c">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4463311-54ae-4cd2-8ca3-912f5d5b266c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74e76f99-02d0-45fa-90ec-ce182ef785a1">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bece1bd4-2c4e-4d7f-b2d2-29fe0a75fe01">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_beb672c7-b76b-41d4-b32b-7617f76e5706">EV <link linkend="DCM_121050" xrefstyle="select: nopage">(121050, DCM, "Equivalent Meaning of Concept Name")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_39e84ea6-6c56-43f4-94ce-c0b660d248c7">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eb918792-2596-47fb-b883-b620713c5710">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0ffa0a2-24cb-43c4-be57-5137e278a01f">XOR Row 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_339bb4c0-1b33-468b-a5b3-158099830c64"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0778c54b-84ad-4187-979e-8a58d47cf3de">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05e69174-8bdb-4910-8425-a49e7161d30e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6630f6a-9ff4-4743-9f78-dbb807058f10"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_77478996-e2f2-41f1-b1b6-34559098c055">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67e44ac4-978d-4f76-8d47-f4124ad472e3">D<xref linkend="sect_TID_1201" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5d76f36a-b555-430d-aa1c-8d6011ef724d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_facc2ece-8853-42b9-9ccb-c6ca7fd12d07">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d55018a9-9e23-4cc2-9f07-e0f06b781ee9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d4643d9-2bdb-4f2e-8c6a-0977488b8dee"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <note>
                    <para xml:id="para_1f63301e-9351-4756-b01b-5f810260a5d9">A coded equivalent meaning for the Concept Name can also be included using the Attribute Equivalent Code Sequence (0008,0121) in the Concept Name Code Sequence (0040,A043) (see <olink targetdoc="PS3.3" targetptr="sect_8.9" xrefstyle="select: docname label quotedtitle"/>), though the equivalent code(s) in the Equivalent Code Sequence (0008,0121) need not be the same as those in TID 1210.</para>
                </note>
            </section>
            <section label="TID 1211" status="3" xml:id="sect_TID_1211">
                <title>Equivalent Meaning(s) of Value</title>
                <para xml:id="para_972d8e3d-2edd-4505-8ad9-d0c04b9769bf">Defines a mechanism for specifying one or more equivalent meanings for the Value of the parent Content Item.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_aab0a786-492f-4a98-a12f-0f9e749bc7f1">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_029eb876-cb6c-40ac-b60b-346f8c2d9905">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_6698388d-af77-4ba4-b8aa-675d079c76bf">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1211" rules="all" xml:id="table_TID_1211">
                    <caption>Equivalent Meaning(s) of Value</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1d0d5811-9aa0-4378-9026-90440491baf9"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7f04c206-b556-4abd-9c16-6042b7adcdb0">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_962ee9e9-0336-432b-a1fc-1ab28285f47a">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e28b9f31-33cc-48dc-8974-c38a6ec42464">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d54988d2-6df6-4522-8ae5-9d008e79d78f">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_80fa5d89-ce52-4dd6-a7b5-0a15f33e51d1">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b2c7ac28-6078-4d6c-8d35-b3183fd990f9">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9ea64899-6191-43f6-900f-3b78fb4157e7">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b2ce2633-0998-4e31-96ca-d0d1f210f366">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03943794-646d-4f9f-a1f3-777d3bb60122">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f5a2090-290a-40e9-854a-299053cfb5a7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fde53675-1680-4142-9b81-8c3f7e085ba4">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fbce37bb-93b1-4daa-821e-089c9e7baf77">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c9dbbd9-68b3-469f-89c4-11e1c64da3bd">EV <link linkend="DCM_121051" xrefstyle="select: nopage">(121051, DCM, "Equivalent Meaning of Value")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ebe0fa9-160d-4388-a5eb-afaf66358dec">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_728977d8-4009-4e1e-8e05-6d39c99307fe">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed04d711-0650-475c-bb18-897ab2847521">XOR Row 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_442a0769-c7ca-4597-9b70-1dc60f846efc">Plain text equivalent of code meaning of the value of the Content Item being modified, in the specified language from the specified country, using the default character set or a character set selected from Specified Character Set</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b747a9f4-b7a9-4695-99f2-8bf4fd335840">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7fff27a-374a-4256-a9ff-c4d176cb3d6d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a61f2956-6811-4090-831f-402e2d2051fc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2d76ae57-c2f0-4a9c-b88e-3b56337cc838">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ded5d8fb-a53c-4bdf-b124-2ab487dec50d">D<xref linkend="sect_TID_1201" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_34da5199-0384-4115-a361-5d4089774116">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c4120a41-3ee4-438c-a747-09a3cf093d06">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dcd7060b-d258-42ff-875f-a97936194365"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc18a17f-1806-4732-bf77-6ebd8a22f3ae"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c49c1298-6170-470c-bb5b-1b0312c15939">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25e67fec-2d60-4366-a402-cfee6b5b7733"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b1cbe46-3436-47a2-9807-6d2d9edffd73">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91a5e0d0-aaf4-4d68-b53e-a49ef9fb8251">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7a54540-82c1-4ab5-9b8b-885689c3405a">EV <link linkend="DCM_121051" xrefstyle="select: nopage">(121051, DCM, "Equivalent Meaning of Value")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7c285a53-854e-430e-a3ac-e94e3e5fbfdf">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e87da870-7752-4344-9257-82b0013f74fc">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_613bef61-e9c0-4338-b5d0-5d1235ec57bf">XOR Row 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c7c89d7-fe36-40f2-bfa9-0f6862a4bc80"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2783997-cd70-4cb0-8a64-2ca77747a170">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f5d61e8-8836-475f-b566-1658bcd34404">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3840bbe8-4422-4889-a927-01f913dd2366"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3d15164-1a9b-4717-9db6-4aa8cfb0d72b">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9e3cab4-44dc-48c0-b89e-0bd3d0538dc0">D<xref linkend="sect_TID_1201" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_054d6980-7e8c-4e60-b9dc-4082854ed3e2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a90b4b1d-43b5-4883-996c-73dc270e401d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37907a70-873f-47ab-9eba-507bf7806617"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e560e3d-f1ba-4d6b-8da3-b8f155fece78"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <note>
                    <orderedlist>
                        <listitem>
                            <para xml:id="para_0b84f292-6b9f-451a-923c-32166f146f68">For example, to describe a longer, more meaningful equivalent (in the same language) for a procedure code than is defined in a Coding Scheme:</para>
                            <para xml:id="para_ac43e162-c5e6-4801-9d64-e3617dc5c893">CODE: <link linkend="DCM_121023" xrefstyle="select: nopage">(121023, DCM, "Procedure Code")</link> = (50291CC, ICD10PCS, "IMAGING:CNS:CT:SELLA:LOWOSMOLAR:IT, U, E:2PLANE3D")</para>
                            <para xml:id="para_9ec1212d-e850-4fb9-8507-51bdda41e260">&gt; <emphasis role="italic">HAS CONCEPT MOD</emphasis> TEXT: <link linkend="DCM_121051" xrefstyle="select: nopage">(121051, DCM, "Equivalent meaning of value")</link> = "imaging study central nervous system of the sella turcica/pituitary gland with low osmolar contrast intrathecal, unenhanced and enhanced, in two planes with 3D reconstructions"</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_5285554a-b5b0-4892-84c7-a773ba88b150">For example, to specify a concept name and value in both French and English in Canada:</para>
                            <para xml:id="para_f2c69a36-1d86-40a2-827c-7e69fe1fd2ca">CODE:<link xl:href="http://snomed.info/id/91723000" xl:show="new">(91723000, SCT, "Anatomical structure")</link> = <link xl:href="http://snomed.info/id/76752008" xl:show="new">(76752008, SCT, "Breast")</link>
                            </para>
                            <para xml:id="para_7b65ceb3-64da-4612-a458-8ab4256bf8f5">&gt; <emphasis role="italic">HAS CONCEPT MOD</emphasis> CODE: <link linkend="DCM_121048" xrefstyle="select: nopage">(121048, DCM, "Language of name and value")</link> = (en-CA, RFC5646, "English, Canada")</para>
                            <para xml:id="para_9c0542a6-dc70-4e6a-be2e-6b8438078ba4">&gt; <emphasis role="italic">HAS CONCEPT MOD</emphasis> CODE: <link linkend="DCM_121050" xrefstyle="select: nopage">(121050, DCM, "Equivalent meaning of concept name")</link> = (91723000, SCT, Structure de l'anatomie")</para>
                            <para xml:id="para_5618284d-57c6-4b27-ae03-eb153657deb2">&gt;&gt; <emphasis role="italic">HAS CONCEPT MOD</emphasis> CODE: <link linkend="DCM_121047" xrefstyle="select: nopage">(121047, DCM, "<foreignphrase xml:lang="fr-CA">Langue de la valeur</foreignphrase>")</link> = (fr-CA, RFC5646, "<foreignphrase xml:lang="fr-CA">Français, Canadien</foreignphrase>")</para>
                            <para xml:id="para_4ea6cf0b-741b-4c9b-92f0-78698c2c7e7a">&gt; <emphasis role="italic">HAS CONCEPT MOD</emphasis> CODE: <link linkend="DCM_121051" xrefstyle="select: nopage">(121051, DCM, "Equivalent meaning of value")</link> = (76752008, SCT, "Sein")</para>
                            <para xml:id="para_f5c06392-1cea-4d61-8451-e2b457d13768">&gt;&gt; <emphasis role="italic">HAS CONCEPT MOD</emphasis> CODE: <link linkend="DCM_121047" xrefstyle="select: nopage">(121047, DCM, "<foreignphrase xml:lang="fr-CA">Langue de la valeur</foreignphrase>")</link> = (fr-CA, RFC5646, "<foreignphrase xml:lang="fr-CA">Français, Candie</foreignphrase>")</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_14e4997e-b038-4ea5-af9c-a63ba453c192">3. A coded equivalent meaning for the Concept Value of a CODE Content Item can also be included using the Attribute Equivalent Code Sequence (0008,0121) in the Concept Code Sequence (0040, A168) (see <olink targetdoc="PS3.3" targetptr="sect_8.9" xrefstyle="select: docname label quotedtitle"/>).</para>
                        </listitem>
                    </orderedlist>
                </note>
            </section>
            <section label="TID 1350" status="3" xml:id="sect_TID_1350">
                <title>Negation Modifier, Presence of Finding</title>
                <para xml:id="para_9cdae2d0-3bfd-41a0-aded-6e0012182550">Concept Name Modifier for negation of the presence of a finding represented by a post-coordinated concept.</para>
                <note>
                    <orderedlist>
                        <listitem>
                            <para xml:id="para_6698ded2-36ce-468b-ba17-570d7259f39c">For example, negation modifier applied to "distention" in the post-coordinated structure:</para>
                            <para xml:id="para_e1299c2b-0231-4d93-96ea-9c1f05720203">CODE: "anatomic location" = "bile duct"</para>
                            <para xml:id="para_cc500c97-07a5-45d8-ac90-a8148a0eb34f">&gt; <emphasis role="italic">HAS PROPERTY</emphasis> CODE: "morphology" = "distention"</para>
                            <para xml:id="para_b8dafdcd-c5f2-41d7-8451-999c4c0224e8">&gt;&gt; <emphasis role="italic">HAS CONCEPT MOD</emphasis> CODE: "presence of property" = "absent"</para>
                            <para xml:id="para_3e01d9ce-cfa5-45ba-bdd2-d3cb4b482b31">means: "bile duct distention not present"</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_bc120747-6069-4655-9fda-904bf2275280">The presence-negation modifier modifies the entire post-coordinated concept, not just the Source Content Item of the HAS CONCEPT MOD relationship. The entire branch of the tree from the Content Item is included in the post-coordinated structure that is negated.</para>
                        </listitem>
                    </orderedlist>
                </note>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_fd453dda-653c-4967-a81b-818b355f2e6d">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_6bd689ad-5039-49d2-b8cb-8dbc6d357f81">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_17f92b67-d70f-471f-aa24-ab9aeaaf8c71">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1350" rules="all" xml:id="table_TID_1350">
                    <caption>Negation Modifier, Presence of Finding</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e4925c76-6199-43ce-9e46-bbe7205f5c1c"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_548ffd11-144b-4e8a-bdd3-1310d55b0ed7">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_57455a76-08c7-40b8-b654-3b575b58f2f4">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d9a4c22c-1e25-4bce-82ce-9bee0566ee7a">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a5f2ad85-754d-439e-a8cd-a31ea1ee0773">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_780f2bc7-0d48-4c53-8a73-b536d9d85ef6">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5551d333-d620-4dce-9605-eb8adef69de6">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e9a871fd-735f-43d6-b744-65b322ec881d">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_68469a28-f439-479e-88e6-7974bf1abf8b">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_297749e4-3a43-4413-be47-3e1937241747">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1dd910a-3ae7-4abd-a728-c2ca92b7a7ae"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d8e49c9-89cb-4d60-afd8-f5a5712ba433">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9023408f-0600-46ce-8ecd-0758b1dd9662">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a8dcf54-7d7a-4a64-b4ab-f01f12243e60">EV <link linkend="DCM_121052" xrefstyle="select: nopage">(121052, DCM, "Presence of property")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b7900cb8-1dcd-499c-9278-f301818d5537">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8cc3e466-7bbc-4a4f-931b-e16e82ad6052">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_569edf26-9aad-462c-b0df-3fcdd88e07ba"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25de234a-c1b6-4f02-8a6b-9b5ccd37fbbe">D<xref linkend="sect_CID_240" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 1400" status="3" xml:id="sect_TID_1400">
                <title>Linear Measurement</title>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_fd258c39-2506-4821-8099-470aeae29a34">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ebacf65e-1916-47d0-9922-f225e1cd820c">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_98f35f58-5204-44b6-87c6-73e02e3ad97c">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1400" rules="all" xml:id="table_TID_1400">
                    <caption>Linear Measurement</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_30bc2f97-ac8d-4f7d-9b42-2bbc0cb2f657"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2a6084a4-5b67-49fc-a7d3-038bd3f6af40">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f1f90a80-af70-4bae-9e9c-e1c7e1ecad38">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e2d8a731-45ad-417d-b730-af5f44d9ec92">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f389275c-b0b9-4410-aea7-7cf2a8afa1e0">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9cf741ba-605d-48aa-93ed-21f3b7cbf9b9">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c5bb33a0-eee2-4514-82bd-3bb90fe05f03">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8685eba6-9e9c-48bb-91ef-064999131cb1">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d5565d82-73cf-4796-aa27-b54df111cb6f">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5f850c8-4cd8-4f29-afbd-55ff6a345c3d">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10cbc8b7-1eb0-4dbf-9e2b-29d6c1e97eea"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b160965e-4578-49fb-8269-8b804b672d8d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7364ab7b-a03e-4475-ac7a-a59809699e80">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_db40c1f5-ad56-4bad-9ef4-5865e3c38328">D<xref linkend="sect_CID_7470" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1e9fd9b8-775b-4402-9bdd-a0af24fc8db5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_64b915bb-01ac-49d9-b2c6-ad62944d8248">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab67fc18-b05e-45f4-9944-359f6b2dbc75"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31dcaa56-2ec1-47ea-ade8-2379819e919b">UNITS = D<xref linkend="sect_CID_7460" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2785d758-8ab9-48e8-9f5a-51802096b325">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35d5d9c1-6d58-4812-8019-20ee1ed0e2b7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ed9f1bc-77f0-4ef2-9239-20432cd96715">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7dcd1e6-32f6-4a25-bf07-e049b9b7321e">SCOORD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_374ad6e6-e1d0-4b18-bfda-9c2a715ed733">EV <link linkend="DCM_121055" xrefstyle="select: nopage">(121055, DCM, "Path")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dbaff369-6f1a-496d-a7eb-f1d68b2b83ce">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3d3e1a4e-df71-4592-993c-8522715945fc">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b2e11cf-daf4-4fac-ba24-ec953e5d296c">XOR Row 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e2bc61a-ec70-4100-ba36-b2c402b094e8">GRAPHIC TYPE = {POLYLINE, CIRCLE, ELLIPSE}</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b609882-fa90-4766-ace0-75a95a2380ba">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_631000da-37da-45f7-84d1-590c5153cb45">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a59280d-77ef-4116-8e32-bb80d458c128">R-SELECTED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27bb4d45-ea93-4fb9-987b-8d28575e8ef4">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce1db8a9-820a-43aa-a19d-a66e49b37d01"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_46934417-ae45-40fa-9b6c-b1555d564c2b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_447619db-d610-446c-aad3-4a5c858a7451">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61811986-5e90-4072-8bce-f98caaab810e">XOR Row 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff75fe12-e56b-47f2-92f8-03aa075c2828"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5326b6b5-ec81-4b4f-9825-0cf661308f66">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fefecf08-2042-4532-9ba6-36cc700de30a">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da9fe5a1-c028-4d43-9195-94c7bc655142">SELECTED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6441cce-b4b4-44bf-b1c3-3de7f9949b7f">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7d1532f-5c1a-48af-98c8-c221813af229"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6a131599-9164-4d82-9675-9e014e4a7b65">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4e62586a-27d9-4ebe-b9d1-16b866b6c12d">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d1dd3bd-64f1-4f98-992c-36ffc15c8e45">XOR Row 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_845db74f-e37d-497c-9b84-554e8b77dadf"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_573836b7-01bc-438a-8762-5bb8bd575cf5">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed1d87f5-9b93-4091-9749-a4d8f02c840b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab4ebdb1-34d6-4556-b72e-ca543e54b9d8">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_770569d0-0c0c-4fd3-ae8e-7ff92a36af5b">SCOORD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ddf91a99-9d61-4e77-9afe-cbe9d520bac2">EV <link linkend="DCM_121230" xrefstyle="select: nopage">(121230, DCM, "Path Vertex")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b583403-6ead-4168-9d30-f61f6ece39e2">2-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a75c1c01-8e9a-4dce-8b81-47a4d2d5b454">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_407ddca6-6dc4-4dd0-941a-a147f8a989ca">XOR Row 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a14bbf9c-6e07-4a5d-b3b8-2df7474ecdb3">GRAPHIC TYPE = {POINT}</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac7fc28b-1dfb-485a-8bbc-bd916bbf5cfa">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_15c6a55c-90a6-4777-9693-4fc34d2c585e">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_225a5527-abbc-4ac8-b68e-eeedc3a362c7">R-SELECTED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a835c12d-fa29-4a9b-8639-7ec457ec03e6">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_136fd3ae-d6a5-49d4-94e6-94f3fcd77ace"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b3bc66ab-1134-4cc8-9bb6-a64011ddfd0b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_abc6eabb-513d-46bb-8700-5b58b2e2d24b">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b76c5ac-92d4-4150-9c4e-27716cbf29b0">XOR Row 7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02321870-191a-481a-b800-dd146f89e899"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b185bfcd-c3bb-4895-a925-b1bbf52358da">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d66ada5-c362-44af-95db-6b1c3c6cfcb9">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73896978-470e-4ab0-b949-143b098b6bd8">SELECTED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac9ade8b-e79f-441e-9e24-f9fd950d11ea">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8faf3e63-3c88-4d3a-ac18-bce419b8714f"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d3ffdb73-5158-444b-a52b-89766afef23d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0abb3f78-c64e-4ed3-b35f-96c922627b10">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b192810d-8baa-481f-91dc-9f7bf2e58b15">XOR Row 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11f9d5d6-e45d-495d-882d-02ef2097631c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_972a4249-ff3e-4032-8ee4-1ffc0d634ab3">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ccfdcd84-4763-40c7-a462-d67f132923ff">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a4826e9-a45b-4dde-b355-fbe9277ffe2e">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e0f1a9c-2839-4319-8695-6180c7c70deb">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5af30036-e2c1-4a6d-8b5c-bf74fa861f58">D<xref linkend="sect_TID_4108" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aad32e61-a366-4dec-bae0-1235d9630533">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73eeb45a-08c8-4aba-b69a-90d0531525ee">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d6b3af0-b6a2-4adc-9045-2ab8e12fe633"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_028cc44c-3a11-40de-aa21-ee64f280bc01"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_ea854f30-0505-4d9d-99f4-ae8728b1c3ee">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_587016fe-6263-4104-ab0b-4c71d1f3245a">Row 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69a64546-1297-4460-bbcc-17b6c4a9ebc4">Path shall represent the measured path or a projection of the measured path in the image. The Graphic Type (0070,0023) of the Path SCOORD shall be:</para>
                                <itemizedlist>
                                    <listitem>
                                        <para xml:id="para_44d904df-e391-4ae7-ae31-f66f5193a66b">an open POLYLINE with two different points (to measure length, diameter, distance, proximity, etc),</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_964be523-31e9-4d29-95c8-bf62df7af645">a CIRCLE or ELLIPSE (to measure circumference) or</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_4536c777-95fc-4203-a292-9c08c1921aca">an open or closed POLYLINE (closed polygon) to measure path length (open) or perimeter (closed).</para>
                                    </listitem>
                                </itemizedlist>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8f3e29b-56b2-4a6c-adfc-a51f9f354945">Row 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_64687ae6-fd5a-4c4b-ada2-e76c52128b84">A measured path that traverses two or more images (e.g., the ends of the path are in different cross-sectional plane images) shall be identified by vertices along the path. The Path Vertices shall be ordered by the order of their SCOORD Content Items to identify the measured path. The Graphic Type (0070,0023) of each SCOORD shall be POINT</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1401" status="3" xml:id="sect_TID_1401">
                <title>Area Measurement</title>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_fa75dec8-a254-45d1-b02f-93c2a494dce4">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_fa6b611d-bd5d-4f40-871a-2cc1a3f47007">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_51c5ba9a-97bd-483f-b46c-0940d96f4032">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1401" rules="all" xml:id="table_TID_1401">
                    <caption>Area Measurement</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_89a8a7a3-ec00-4eb8-8d9b-800ac3382a31"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ab85d587-7fd0-4fa4-9366-f285ff19d072">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_faa559d7-90d7-4427-9c1b-22fd1dd3eb78">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ebd7c861-c379-4307-8464-300bd992ffb1">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0e819a55-2556-4162-97fe-dcbcea279954">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3c840f33-f74d-4396-8fc3-fedaf536ddbe">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_27cce8f2-c4b8-48e4-98d3-393b2fc4d761">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7124baf1-ad43-4fd7-9e39-eedb26c9b821">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_37b0bf1c-8f1d-4a66-8d3b-d816a89138a6">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_01c35ea8-d3c7-4c95-8597-7ff4881ae224">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09a1492f-2c96-4c36-8464-47885c7e2037"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_734f2f0b-c68d-4841-b149-bd13b7af1772"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c6757764-4e29-4fe9-812c-8780a052311b">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb5eaa88-5edf-49b6-a82e-325ecf4ead8f">D<xref linkend="sect_CID_7471" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b8e44605-5354-4e0d-a2ed-7bd2ab75c5b2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dff635b8-fea6-4e76-8a54-ab4a81f66edd">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63dc0f1e-a9df-4f8a-b0b3-3352b5de66e9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f4f0fd4-8d35-4901-a5f5-1c1d9c36566b">Value shall be &gt; 0</para>
                                <para xml:id="para_2e891566-dd43-447f-96d5-f9ed6a60f4fb">UNITS = D<xref linkend="sect_CID_7461" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a1e4f34-7041-4de4-9087-ac1afa2d74bc">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e48c37b5-0f4f-45e6-a2d4-1ff767e97b38">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d75608d-ed28-4116-b2cf-0b2eb925f6f2">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21575a0a-8004-40b8-97e3-b6b7d2ad363b">SCOORD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff188373-3162-4554-bdd3-914a7ffb3e18">EV <link linkend="DCM_121056" xrefstyle="select: nopage">(121056, DCM, "Area Outline")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fad2b8fc-1528-413d-b2af-a17d0696ef29">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73e89d79-8208-482e-ac3b-a9cf0d3dad33">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_225eb368-ff74-4047-b08e-316cabb00ec6">IF concept name of Row 1 = <link xl:href="http://snomed.info/id/131184002" xl:show="new">(131184002, SCT, "Area of defined region")</link>, and IFF Row 5 or 6 not present.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93f34f59-eaa8-483f-b428-0851048d399e">GRAPHIC TYPE = not {MULTIPOINT}</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a91d04ed-9b09-4349-a350-dddc2577e662">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d771d2ad-f463-4382-b4bc-8bbc82913012">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4023b1d3-707b-47b0-8e6b-a7089c1876ed">R-SELECTED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_863def40-614c-42f2-8c80-a8a65a703e12">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_efb1c148-60a2-444d-8d09-24f7ce3ecaa6"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b02037ce-e0c9-4ec9-9403-98a8395024aa">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d3f9311b-8a47-4dc0-ab42-28bcbf5db96f">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0610bbf8-8ee2-4dd4-a89a-c13bbbfd5c79">XOR Row 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e150308-07b2-4585-ac27-564b7c79de4b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d97e2786-dae7-4ba7-9584-54b8fd3ac9be">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb6b2ee7-f89f-4a15-99e9-47d0abaed5a4">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55fbad54-f1eb-4076-9352-896cf32bd1c5">SELECTED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_835b2945-6cd4-453f-985a-fa398bf258bb">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f61da3cb-4485-4b32-ba0a-52dacd6417bc"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a468dffe-f345-491c-b376-4624eda4befe">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ca41ddf0-2874-4790-9485-ed366c8ccb95">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d82c80c-2309-43a4-b8a5-fcf40193a3f7">XOR Row 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3eb8211e-bf13-450b-8bbe-507db8c2b075"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9401a623-af6a-4102-902c-ce6dac330026">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f5f1382-8c56-4afc-ada7-4d4f900d5195">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6107f8b-6104-41b6-a91d-0eeed39e6207">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ca54af0-c892-45c7-9620-b187b1dfbcfb">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99de44a1-3fdd-464a-b5e9-6785c2766ab1">EV <link linkend="DCM_121214" xrefstyle="select: nopage">(121214, DCM, "Referenced Segmentation Frame")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c54e60f-382e-4a98-9a16-f7bbc17fc44e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aed497cc-a4aa-45e4-b9f7-147315be6811">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b724e588-3bad-4aac-816f-1492bef8aaa9">IF concept name of Row 1 = <link xl:href="http://snomed.info/id/131184002" xl:show="new">(131184002, SCT, "Area of defined region")</link>, and IFF Row 2 or 6 not present.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61da302f-b92b-460a-bc58-67fd6cf92b8f">Reference shall be to a Segmentation Image, with a single value specified in Referenced Frame Number</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37f8117c-77a8-4ae6-ae87-9f9b84ee0448">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_812d7703-8205-494e-bc29-6b83921b2009">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d3a3b53-fe49-461c-b1b2-214859a3870f">R-INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3bea9e5f-476b-4ad0-aab5-511dabc8c668">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96392154-2603-4d8f-80b1-b0395d567500"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8df3a097-0b74-4280-9f12-bf4bac47df6e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3b4a13f1-328f-4cfb-9a00-1007d9523334">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a140d25c-1315-4ac3-944b-5c3590eb4bba">IF concept name of Row 1 = <link xl:href="http://snomed.info/id/131184002" xl:show="new">(131184002, SCT, "Area of defined region")</link>, and IFF Row 2 or 5 not present.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57670112-dd9b-44f1-9177-a598d428481e">Reference shall be to a Segmentation Image, with a single value specified in Referenced Frame Number</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10babb7a-6364-4ebf-a9a4-46b75d885aa1">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef4cb22e-6347-4046-84e7-1da0384da2a0">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81b9b233-01d1-447b-8fa2-dcaf760051a6">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5d3f275-d6d8-4eaa-a97b-3881391d0e88">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79a38a1c-fd40-4870-a2e1-3c81e4fa5d3f">EV <link xl:href="http://snomed.info/id/370129005" xl:show="new">(370129005, SCT, "Measurement Method")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_713aa202-4b18-4729-950d-922ea520066d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_72b1b89c-e320-49db-80c7-2d0ba26774d2">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8535618-83c3-4524-b589-a864c39399ba"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74fe11ab-cb6b-413a-9d49-43b325d6b776">D<xref linkend="sect_CID_7473" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43ad30d8-5f6e-458d-a194-370106f3eaed">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_129c96b5-862b-4ee0-a01e-6dbfcc11cee1">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c864d9f8-4e96-4128-8ca3-74eab3140b59">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef9e00f0-3ccc-48bd-8a11-b1d774e05157">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9d83b0a-9778-42c5-866b-235eede4505a">D<xref linkend="sect_TID_4108" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7c535853-e9e4-4146-b5da-e3c6ed3166ff">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_698c9555-90fd-4514-a661-3117947b94d5">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2354489a-4df6-4379-b650-f2a9d4b635e3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_494dc3f8-0cc1-4c6d-8748-683d625f5e6f"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_92114ec3-167a-44b5-a704-dc097702506e">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b364f7a-f211-441c-a653-2e56bc5e7d76">Row 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e50d456-202c-40e3-88fe-d880e4ece0ec">A Graphic Type of POINT implies that the object is a single pixel and the object's area is the area of the pixel. Otherwise the type shall be a closed POLYLINE (start and end point the same) or a CIRCLE or an ELLIPSE.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_825cd70a-abcc-4bd2-b6b2-79a110d19a24">Rows 5, 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de217bbb-6af9-4266-bb22-71a6cdd5da61">Referenced Frame Number (0008,1160) is an Attribute of the IMAGE Content Item.</para>
                                <para xml:id="para_36a48d1e-d091-4503-b685-13bbcb64332e">If the Referenced Segmentation SOP Instance has Segmentation Type (0062,0001) value BINARY, it identifies the area of defined (measured) region by pixel values in the referenced frame with value 1. For Segmentation Type value FRACTIONAL, the area is computed by an implementation dependent method.</para>
                                <para xml:id="para_9e5eaf07-47b3-49e4-8eda-6cafa194ea04">Frame number shall be specified even if the Segmentation SOP Instance has only a single frame.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55050e21-6e3a-4de2-9a07-e1eb629e3e61">Row 8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25dbde8c-d0d0-4644-a1ba-b2ede26fdb68">The values of <link linkend="DCM_112039" xrefstyle="select: nopage">(112039, DCM, "Tracking Identifier")</link> and <link linkend="DCM_112040" xrefstyle="select: nopage">(112040, DCM, "Tracking Unique Identifier")</link>, if present, shall match the corresponding values of Tracking ID (0062,0020) and Tracking UID (0062,0021), if present, in the corresponding Segment of any Segmentation instance referenced in Row 5.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1402" status="3" xml:id="sect_TID_1402">
                <title>Volume Measurement</title>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_6384ea53-6dc0-487b-82ac-2e7f4800a349">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_6514d03c-2d04-49a8-861b-f7dcf0dcfa50">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_9d7b8465-6afd-434c-a654-07391c3644b7">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1402" rules="all" xml:id="table_TID_1402">
                    <caption>Volume Measurement</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_97a310c5-0588-41ac-88fb-6fe3e883b221"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_01406997-ad9f-4b41-b812-0d05ef25e0b9">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8107f3bb-35b0-4b80-a5fd-70bc75e51a09">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bfee7b1e-cdd6-48a6-afa4-5cd4cb514074">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a5d25045-2150-4517-b815-09f8407ddbde">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_70115a1d-eb49-4593-913f-fafe572cf62e">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c0fc238-8d06-45be-920a-e7b564383f5a">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9724c45e-2db2-4da6-9339-9f9a08c22bd1">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d46d7bb3-2ebb-4fc3-ae8c-f357dd9c23c3">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7fd59d86-cff0-4966-a1ac-42256f4bce69">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5531c97-00c5-4ce9-867a-6836db942741"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_53bcd335-112f-4e39-868f-c6d9e72ab417"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a0b685e-ea06-4dd9-a44e-98a53480e2e4">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd7d6bec-9a4b-4ba8-ad01-85a9b34ac1d9">D<xref linkend="sect_CID_7472" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4ab0f04d-096e-4ff5-946e-33898169d6ed">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2ed7b39f-6a3a-440b-9167-2b831abbdd6b">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c80df7aa-f0be-4474-a09f-ff68297a334e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_828f9db5-2299-4062-abe7-0832bb30a61e">Value shall be &gt; 0</para>
                                <para xml:id="para_0a7276fd-784a-4d79-bb69-3cbde28698cc">UNITS = D<xref linkend="sect_CID_7462" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ea3116f-973b-486b-941f-5ebf2646c7c4">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc6ea2a6-090a-44b1-ab84-a42ca0115538">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3743b76e-2496-4434-bb4d-032e89bf3f45">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d9fb44f-08c9-4e39-9d13-f003800ee237">SCOORD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_15b00314-25a0-4564-97fa-ce841db9c258">EV <link linkend="DCM_121057" xrefstyle="select: nopage">(121057, DCM, "Perimeter Outline")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4c4b509a-bf18-4953-a248-a04b7258f001">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e71de81c-5aff-4f7d-9d24-7880b072d955">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d654aaa4-d322-4875-b6ba-ed9c606993fe">XOR Rows 5, 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22f26231-3c69-4064-84df-45f03dd32d68">GRAPHIC TYPE = not {MULTIPOINT}</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30d65c38-00e2-4312-89e8-bd7b371d394d">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38baffd2-eabc-4c3a-9b77-263a4b2158cd">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c062f2b2-99cc-4164-b27f-d10379966cd9">R-SELECTED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de9fe0a8-ef1e-46c2-9b52-60967379d601">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27df741d-73ea-4103-8df1-93effe097677"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0d9ce2ac-53ac-442c-b259-e0bb680eaed9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0cbee325-20b6-411b-ab8e-f9ce47f9bd94">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_718a1b61-a771-4062-9fd0-8456ac77e803">XOR Row 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0c372f54-cc47-4d2b-95c7-6758c8aab9db"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d858a9f-efa9-42dc-b5c6-c2d0fa71cd80">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cacfa7a5-ba15-492a-9cba-5903f29fbc35">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c99124f7-a2c0-4621-af39-ad13d80a9745">SELECTED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30fc9d1b-5ebf-47c5-90ed-e3f749ce9a93">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2cdf8c31-74ef-4a1d-b6db-bf891dbb03cf"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d71640d2-e5a1-4794-b427-68fd653b34d5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5d55a425-9e42-4a72-a6f9-68897c67a4fc">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cab79b77-1609-4746-9c13-16c5a6028687">XOR Row 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75d68d28-6447-4a40-a6df-76af466cbfbf"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a09ca001-3196-479f-9b20-1f890932504e">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1c72dff-c9dd-4da3-adb9-82cf95ffff78">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_486b70d6-7253-4f84-820b-92b3a22789ff">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03bda186-3a33-4761-8a60-f400db97cd16">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_07f50702-ea40-4544-873a-1518aec7559d">EV <link linkend="DCM_121191" xrefstyle="select: nopage">(121191, DCM, "Referenced Segment")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_67ac3cf2-fa6d-438a-9f35-e37c567b5f66">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c6273704-131f-43d6-8f94-63a259288f45">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_89a9d0fc-f078-47f4-b9b6-6f7826945cc4">XOR Rows 2, 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9888ba73-60de-495b-817b-0ac5a09fd587">Reference shall be to a Segmentation Image, with a value specified in Referenced Segment Number</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7f0b3b0-dba9-4c35-a564-0e80ed688b9d">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1f711249-1593-45d3-aa2e-35db20d2a4b5">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f91e936-2a80-4ab2-9189-dc1e1a3d0b1d">R-INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ec77d67-b456-45f2-b124-9abea2b67a88">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_33d0f44e-cbd6-41b9-b47f-04607e9568cc"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0eb648aa-13cd-4541-990a-9a2deb8250af">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ddca663-c724-46f5-9972-97f241fd1ad9">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6769981f-8547-4656-81a4-6f2fad564bf4">XOR Rows 2, 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55d990ed-66e1-4470-8c02-9178aa122cf2">Reference shall be to a Segmentation Image, with a value specified in Referenced Segment Number</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0bf3e5a3-17c8-4400-ba3d-c65374afc145">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75631fcb-bc80-4271-95dc-6b6f69b71141">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a170d7e9-22e9-403d-95eb-2b74bc371f28">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2015350e-b471-4230-baad-6f205b96005a">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e1b2da52-5d30-4648-a121-6bd5f9e4bcd4">EV <link xl:href="http://snomed.info/id/370129005" xl:show="new">(370129005, SCT, "Measurement Method")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_069f0dd1-b70a-4c35-b79f-ebf441c01e7f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb629695-0c80-405e-9b0b-450b67cab454">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2d9959a1-51ad-48c6-af7e-09b214f7ca41"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a84a2bc5-ca38-46b2-a834-9a1fce6f9563">D<xref linkend="sect_CID_7474" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5fbaf8c-bd9b-4652-bbd1-b5a025952f89">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fbe2d809-25bb-4129-8c90-072c995be59f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d872b020-5c81-4f1a-9022-7dc90a774a12">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf3508c2-c32e-4c56-9b01-b53d0e5e79ff">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_555cadfc-5afc-4679-86ef-6cf7e62c5b54">D<xref linkend="sect_TID_4108" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4e410f54-22df-4f2a-a170-0073099c0781">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3c5ea6ae-2fb9-4158-82e5-a1c584b67685">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_966560a6-0633-46c4-8870-2296da8c1ab9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79fd4497-845d-455d-bf83-35af72ef728c"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_ae51fdd7-b603-4da4-8c4f-b4b1be079064">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4866be39-de3f-4453-98ca-2853a660b148">Row 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27864afc-62c8-4800-9dd3-211ea36c7a0f">The two dimensional perimeter of the volume's intersection with or projection into the image. A Graphic Type of POINT implies that the volume's intersection or projection in a plane is a single pixel. A single pixel projection perimeter cannot cause a volume calculation to become 0.</para>
                                <para xml:id="para_be77a957-a9c1-49c9-b532-bd5248bc6ec9">Otherwise the type shall be a closed POLYLINE (start and end point the same) or a CIRCLE or an ELLIPSE.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5959b9b0-cf55-4253-8750-7d325bcf69ed">Rows 5, 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb17acac-969d-4cb6-aa11-44ea2011af7d">Referenced Segment Number (0062,000B) is an Attribute of the IMAGE Content Item.</para>
                                <para xml:id="para_2217a132-8a0d-41e2-bec6-816e8ede626f">If the Referenced Segmentation SOP Instance has Segmentation Type (0062,0001) value BINARY, it identifies the defined (measured) volume by pixel/voxel values in the frames of the referenced segment with value 1. For Segmentation Type value FRACTIONAL, the volume is computed by an implementation dependent method.</para>
                                <para xml:id="para_608150b8-92cf-4934-bee2-a41359024399">Segment number shall be specified even if the Segmentation SOP Instance has only a single segment.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0c0510a2-d811-4742-912d-6c7b596e83d3">Row 8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4834850a-441f-4be1-8c3b-592207569b30">The values of <link linkend="DCM_112039" xrefstyle="select: nopage">(112039, DCM, "Tracking Identifier")</link> and <link linkend="DCM_112040" xrefstyle="select: nopage">(112040, DCM, "Tracking Unique Identifier")</link>, if present, shall match the corresponding values of Tracking ID (0062,0020) and Tracking UID (0062,0021), if present, in the corresponding Segment of any Segmentation instance referenced in Row 5.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1404" status="3" xml:id="sect_TID_1404">
                <title>Numeric Measurement</title>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_9901055a-f2eb-49ff-ab95-c9b1ee37e639">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_44e13c31-a768-48a7-9c6d-8c9c91ec4a7d">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_285d05b0-4648-43df-98d0-4968c2196722">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1404" rules="all" xml:id="table_TID_1404">
                    <caption>Numeric Measurement</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f5d2f2ad-fb38-4735-bce9-386d1b6e237c"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_34eee8b4-6245-44f1-a4f7-40eeadce7b0a">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a5757adc-d0cd-4fd9-8e1c-5948b4bc26ef">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0395ba29-7a96-429d-92ef-ddf1f3364528">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b2fd15d9-63a7-4c1d-a6e3-4c336375b4f4">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f2769a29-1a65-464b-9248-a449fadfe230">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dfbdae60-eab9-407a-aa46-8ed5d87be19b">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8d339454-7ea2-4654-843b-8b848d32e445">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9bc3de8a-8797-455f-aa9f-4e4a39b7c801">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_49225e37-a8e5-4889-93cf-8d12c766c862">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b1added-0375-4644-b069-b73912cf690a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eea9ca4e-eb0d-47df-bf0a-6f5cc16f440a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_410cfc22-13bf-43c0-8c9a-0d643db03a32">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1bce768-9ed2-4e29-944f-ea0e12fc9386"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1fcaa233-6f85-47c6-ac7e-67f9ee0ffb21">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1f921735-d948-4a00-8dee-a56fb902efed">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3e5dd07-58f5-4dd2-82fe-7ad0cbdcf89c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f36d20df-156e-4418-a69a-497e93b6b202">UNITS = D<xref linkend="sect_CID_82" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31c3b0fb-3d48-42fe-9bdf-6dcdfbd8be30">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99ef0588-6987-4936-afe8-625a4648b35c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b765655-5008-4838-ac47-cf496e7bd2e2">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_101da4e2-5721-4b05-bacb-c3ac4eec85af">SCOORD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ed21890-99c0-4c55-ae51-483f0cb4b9b5"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8ef8eae2-f64a-4552-8e6b-c0d5a34b7c31">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cfcca606-ca98-4bd7-9289-a6ef377bde8d">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c6fc6018-f284-45cc-876d-db2aeda0b495">XOR Rows 5, 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ca49323-4016-428e-9e1f-6e4f34064590"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b8c384ab-ae00-43bb-955e-9e4c61ce8e2f">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6691d2ec-7e50-48ea-8885-29421a85f434">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50fcc950-f874-4caa-bdcd-79a7348ed6ad">R-SELECTED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9a946a2-5aa1-42d2-a29e-7c8c75da9886">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb14e008-ed6b-4460-b9a2-5cff787073cc"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a2b78f69-eb1e-411f-b1ae-0ff45ca749ff">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1cf5ccab-ac58-4f5a-82b4-52853b3a9613">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da3291f3-245b-4e32-b08b-79394887b101">XOR Row 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22327e02-d1c1-4fdb-b823-4b911339adb9"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e3f9c39-44e1-4522-b8ca-7c4934a206cf">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_deec0a10-459f-477c-9177-48ba748f2d6d">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_15795881-a045-4009-9b72-65ce7cb7f2b1">SELECTED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cecff26a-27c3-4ddc-854f-a8f7e8040e13">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17042318-b78d-4abf-af3b-e7303adf61a6"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_48dd5ce3-3cfa-4213-ba0b-da7d179d1200">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_43f7dc62-c78d-4d15-86f7-f2cb20e61454">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b68f068-3d6f-4b03-bf92-48276e8e6937">XOR Row 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6be8738d-097c-415f-a13c-02373806d90c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_567d2082-e54e-4ef1-a668-cf4ad5f7618b">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_004d373e-cc28-4cd7-aba8-6572ec4078a5">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1947a707-3dd2-4cd5-8089-a86b07bd6af6">R-INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf3b270a-c9e9-4f52-9e26-b2d46282a4ed">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b7e22ed-73cd-4e1c-9d45-3792b127460b">B<xref linkend="sect_CID_7003" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_143a1296-3eae-4721-983a-54abc880b856">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a6f702be-1fb9-4b7c-9aaf-7766a461311b">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5eb760ec-c774-440d-a683-5cfed0dfa8e1">XOR Rows 2, 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e30e9be-9445-4676-b113-ca7e714d3cf5"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b7f36a9-d82f-4d95-af64-9f9177339549">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9de0472f-b44d-4e62-9d04-1f9947cb44e0">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d813786b-e007-4922-abbf-3cd7c3504bb3">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42d67514-eaf8-417a-bae2-37d03457b0e1">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_196545dd-c919-4fbe-8188-6612222391ae">B<xref linkend="sect_CID_7003" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fecdf406-5cc2-4243-a894-e4eb3f5bb0a2">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fa898177-e49b-4889-b018-f9731a2783bd">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ecfdf88-d0f0-4976-ab7c-374dd25ca320">XOR Rows 2, 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65cc80bd-ede8-432e-8291-875370b75a9a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c57b822c-20e8-4b93-b2fe-d0c2801217a4">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_821a8c49-9f53-457f-995e-fa1abc407b49">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_119f6127-ce13-4c52-bb17-44a6522341eb">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b35cc523-aa69-454b-95af-f2a2fce5acb5">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52f75e59-af10-4226-be55-b7cf06adccd1">D<xref linkend="sect_TID_4108" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aa91d6ae-6763-4871-bfc3-6ee0ca2f8829">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_92d6b758-6266-4ed2-b7c9-c2ff612ef9a8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f7828129-a0fe-447e-9951-fd13c9a17ca4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_278889f0-3afa-4d3a-aeb0-01415ffbd335"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_3f8ee7f9-d27a-470a-87a2-2c0b680de9f1">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_868b36f6-288b-4ef7-9816-92151e77aee4">Row 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5475b750-cceb-4d31-8697-6972a925e7ee">The SCOORD may indicate the points or area where the measurement was taken (e.g., a POINT showing the pixel location of a density measurement, or an open POLYLINE of three points showing the calculation of an angle).</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10151589-4cb4-415c-94e7-ca348e36e519">Rows 3, 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c912a2e7-696f-4f1f-a405-9ef69e2965c2">Valid only in IODs that permit relationships by-reference.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1406" status="3" xml:id="sect_TID_1406">
                <title>Three Dimensional Linear Measurement</title>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_be52c8e7-db7a-4288-ae7b-91888c140b75">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_9a7c21ec-e012-4ed7-ab1c-f6651329edd7">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_9e26907a-f839-4b8c-a171-88db0537e681">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1406" rules="all" xml:id="table_TID_1406">
                    <caption>Three Dimensional Linear Measurement</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73f78848-11c6-48c5-b25c-27ba34497f50"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bf0d1e36-b173-4b6f-bf0a-44483f6ed2f6">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1af9eb94-8bf7-43d1-bd06-783aa5c62741">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1f790005-4bc9-4499-9974-1c3330606c4e">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5d12fb9d-e19a-460c-a92e-56975d7c109e">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e0b9f0c2-b8f5-4a13-b3c6-29693e250ede">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f69b5fc2-4c9a-41fd-ba5a-9c819258ce4a">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_585fd73c-9812-4080-bc6c-e1b0d2bd86a9">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b09b541e-7e11-4848-af7c-d914a535f435">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1bf294e0-a240-4009-aaa3-a3d3272fd66a">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3526e67-4e50-4be8-bd5d-c4c8c407e062"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c9b6489e-3419-45bb-adb2-91500e575234"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_829c444c-98c6-4962-a75b-06e40f0bcae6">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ffe059b-563e-4a50-bbfd-3a73db7ea77e">D<xref linkend="sect_CID_7470" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_30cc003c-b0e3-48ce-8778-82ffa2298ae7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9b5ea895-df10-4801-8353-8befb6f87d6e">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0766e957-1a5a-4e28-b733-3402c8ff9d63"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ec653e2-6a82-4399-8ef3-066bb37c698d">UNITS = D<xref linkend="sect_CID_7460" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_07cbe690-f5e5-494b-ae22-e8efc9f432aa">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3fa3d406-bfbd-4986-9b79-fd33d9ae2cab">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_abf87020-12e4-402a-83e1-17243376fcdf">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69654bfa-4cf1-47f3-8722-65601138f3d0">SCOORD3D</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ab6e76e-c4b7-4259-859b-d24615f70351">EV <link linkend="DCM_121055" xrefstyle="select: nopage">(121055, DCM, "Path")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8b8604cb-3fbb-40a3-91e8-0d2083773549">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5e5b54a5-43c6-4bc3-9eed-913531bccf54">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_749d31b5-eb35-44c1-a68e-5f91593b2981"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a0e6452-3e5d-4626-92ca-4bed1d96edff">GRAPHIC TYPE = {POLYLINE, ELLIPSE, POLYGON}</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_821ee2ba-2c90-4b90-a83f-6b260ead6f3b">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74b21171-3bcf-4ccb-89d0-f2de909e95af">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_41af6390-9897-4fab-8aaf-185a5303681a">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dbea1147-57cd-4da7-a5f0-662443e08d80">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0567307e-6712-4dc9-8792-c00d0380e6b6">D<xref linkend="sect_TID_4108" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2d58874d-8134-4d83-9920-6b34711a8d1a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4212dbda-53fa-4c02-80f1-87f62376e192">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27a8afc8-875a-43a1-be2c-eb34c1cdfeb5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ff514d0-020f-4836-aa82-fbf4cdc3f45a"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_0ba03c7b-8cc2-4f76-a79b-f3cc86e945dc">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c8b9f5c-b02c-4cc5-9d92-f2963ea151ca">Row 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b20b002-722c-44b0-a53d-ef3dd25a8a99">Path shall represent the measured path in a reference coordinate space. The Graphic Type (0070,0023) of the Path SCOORD3D shall be:</para>
                                <itemizedlist>
                                    <listitem>
                                        <para xml:id="para_ed2b4ae5-1da0-401d-9b71-25a6612bf758">an open POLYLINE with two or more different (x,y,z) triplets (to measure length, diameter, distance, proximity, etc.),</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_50178609-236b-460f-9f46-1e92a7f6a75c">an ELLIPSE (to measure circumference) or</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_552efcae-c370-44d2-870e-14f93d84f8f7">a closed POLYGON to measure perimeter, where the (x,y,z) triplets are coplanar.</para>
                                    </listitem>
                                </itemizedlist>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1410" status="3" xml:id="sect_TID_1410">
                <title>Planar ROI Measurements and Qualitative Evaluations</title>
                <para xml:id="para_47a24b81-ef09-41fc-b6aa-1cd54a1889dd">This Template provides a general structure to report measurements for some metric, e.g., density, flow, or concentration, and/or qualitative evaluations, over a planar region of interest in an image. The ROI may be specified by an SCOORD on an image, by a Segmentation Image, by an SCOORD3D defining an area relative to a 3D Frame of Reference, or by a reference to an ROI defined in a radiotherapy Structure Set.</para>
                <table frame="box" label="TID 1410" rules="all" xml:id="table_TID_1410_Parameters">
                    <caption>Parameters</caption>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_683ca878-545e-449f-b0bd-566ef059554c">$Measurement</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d66def76-9bff-4401-8087-e8ac8d5333bd">Coded term or Context Group for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4146bcf0-b754-461a-bb46-e8b015f5e6c5">$Units</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_704b685c-a20a-46f3-ab56-ea8c39c54b42">Units for the measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa3ab755-e95f-4ab7-966e-a144423148c0">$ModType</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8fcc35d4-99b1-4b94-b87c-b10fd8834ee3">Modifier Name for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7f3fd32-b6a3-4388-950b-13bb57b8a60b">$ModValue</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8cad84c8-5b90-4cdc-be20-1210ccbed699">Modifier Value for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_66887e47-4d27-4ffd-8a62-1247422ae8fd">$Method</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8dbc6ba7-0adc-4b80-acc4-90c64f60db8d">Value for Measurement Method</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63bedb41-69d4-4896-9af1-430cfda63caa">$Derivation</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0fec3b35-6dfd-4871-a4ad-46085e338b2e">Value for Measurement Derivation</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c448aada-f3e9-4f53-b469-6de36f45db33">$TargetSite</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26357795-6f12-42eb-b4e2-f87ce9bb02d9">Value for Anatomic Location of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac81743a-23ae-42ec-b84c-732ac9be42b0">$TargetSiteMod</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e70e901-04f0-4cd0-8eb4-b3403ca934e2">Modifier Value for Anatomic Location of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb9806cd-a2fa-434a-880d-35f08a7e8560">$Equation</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b59cb529-9188-4afd-b335-ab2d3da2d232">Coded term or Context Group for the equation or table from which the measurement was derived or computed</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_41acdb21-fbc1-4b65-be6c-1f01aaaf6c22">$RefAuthority</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_118d4353-0108-4a72-bc46-03db04c54112">Bibliographic reference or authority for statistical properties of a reference population</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc852428-7a91-411d-9afd-ebae113452d0">$RangeAuthority</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df93f531-0ea7-4671-8751-2f7281c67417">Bibliographic reference or authority for the normal range of the measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10df69c9-6ebb-4172-9f22-721adf93e0e1">$DerivationParameter</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6c8af31-5ba9-4992-ad04-d6ab68edca9f">Coded term or Context Group for Concept Name of a derivation parameter</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_07c15e03-49d7-441f-ad34-d0a334324ec5">$DerivationParameterUnits</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91a3a4f1-19d9-48af-892b-426a6623d55b">Units of derivation parameter</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_400d1681-5556-4a14-842d-9241feace9ab">$QualType</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3dcaeb7-2ae8-4bbd-b8bf-9107eef6807f">Evaluations encoded with code or text responses</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_44cd80f0-5379-4892-a463-5158a289c44f">$QualValue</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22c6760f-2524-4f7f-a324-76665785c132">Value of evaluations encoded with code responses</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ebf19a6-2586-48be-b903-f606e00acff7">$QualModType</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9368ad08-8b09-426f-9e12-fc4e2b5cad4d">Modifier Name of evaluations encoded with code or text responses</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61be1664-4195-4a97-b79a-4ba231463052">$QualModValue</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ceb82c4-b8cc-48c9-b4cc-a8ef0c40da62">Modifier Value of evaluations encoded with code or text responses</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_78bb2f6f-b14e-4c69-bca5-ca5321b5825d">$FindingCategory</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e3f3973-ff36-4375-b390-4e2c7b714ac7">Category of the finding</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ea4ba14-5fde-42b2-a4eb-73fc0f3ecc05">$FindingType</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57719c85-9ca2-4dcb-9ee1-50fccf227fa1">Type of the finding</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74d8b5ea-e27b-410a-8891-b7a92fd01592">$TrackingID</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_db3b4725-36df-4f2c-a3ea-fb0bed91a3c4">Value for Tracking Identifier</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_edebee4c-0cdb-4257-ba50-4dd1580d1c89">$TrackingUID</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ad8507e-b6ff-4870-bd98-ef25091efc19">Value for Tracking Unique Identifier</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_896995d2-bb02-4ecc-a7ec-e2c009204a29">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_59a50759-3b3e-4011-a74c-a13650adca91">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_fee9a913-e21b-475d-974c-8cbb01bf0e03">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1410" rules="all" xml:id="table_TID_1410">
                    <caption>Planar ROI Measurements and Qualitative Evaluations</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_30b4aee0-ea2f-4145-8208-793586b42cc7"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e2114728-d791-431b-9191-bc8f10b33fb6">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ebe5dfb8-ae20-4bef-910d-06c15730b75b">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_11076f1d-2653-47e3-867d-98687bcf34d3">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0e28dd32-3fea-42af-ba33-fb3836638cf4">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b53dfca1-52dc-4c1a-86ae-6e7da6594631">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fdfbf0aa-9607-43d3-8888-66cb7b9ecd25">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_98188a1d-f8c2-4703-b93c-1bbbda3c1e56">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4191d21b-4639-4e6b-9acf-3961b18247e2">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bda96106-9fc7-43dd-a450-a91a0a6e6fca">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_71a85977-09a6-44a2-8acd-8142481e9370"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_489b564d-d244-477d-bd40-a3039fc941b6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6aa1279-28cf-49b4-9778-3eec192f8b70">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f372076d-6d4d-4f09-bbdc-e10f7d314c85">EV <link linkend="DCM_125007" xrefstyle="select: nopage">(125007, DCM, "Measurement Group")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b6fcff3e-4c4d-4a1d-a7ea-d26a8443c9e3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_da8a0eb6-8b06-4635-a02a-cba4d9ce5d6d">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_71881a64-73b5-48d6-b0b0-fbe9806900be"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_07f57d22-61b8-4875-bd89-d3283d0dbdcc"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb0e53f7-4360-4bdc-90f3-8a0eceeb1ef5">1b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_156f7617-86c4-4f6c-b54b-caf1b3189fbb">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_276c3053-b014-48d2-a7a7-55cfc41f878f">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_41a9d7d3-bf90-4341-8ad3-9837ad16c24f">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a7b3a52-1412-4e42-9d2d-0cfa9e7d62a0">EV <link xl:href="http://evsexplore.semantics.cancer.gov/evsexplore/concept/ncit/C67447" xl:show="new">(C67447, NCIt, "Activity Session")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f859274b-a604-4548-87e7-eb0fd5b28d7b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c455c16d-f3e3-455e-be7f-b95a4ac1edd5">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea4722b2-6f7c-4c8e-bb0d-8a806ebab8fc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3890255-829a-4c67-ac45-36643d998a30"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b7cdf8b-16b4-46aa-9bc4-816708331bea">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b84785a-eedd-44c2-afcb-c3480422eafb">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae6e551e-dee6-41e2-a482-3b322d233e0c">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21e14d59-ee4d-427f-95d0-9dac21319d91">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08238c5b-b4b6-474b-91bc-3eec494fa324">DT <link linkend="DCM_112039" xrefstyle="select: nopage">(112039, DCM, "Tracking Identifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_585521eb-f7b0-428e-b42c-83fd01d19038">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5787fbef-a630-49ff-b980-32e703ec9e11">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b864d40b-2e82-4b63-8605-522d254c09cd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b82c9ccf-f272-47c4-b214-75524515fb8d">$TrackingID</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61eea44b-9345-4adf-bd2b-da7e4f0cfd3f">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6518a43-bd91-477f-8163-22f87ce8399a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3163fac-58ce-4b74-9c4d-ae5b5c3b1c4a">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7eb648d-b8c3-4a65-aea0-241b45a29080">UIDREF</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d75bac53-c1ad-41a2-9c6a-a414c5433710">EV <link linkend="DCM_112040" xrefstyle="select: nopage">(112040, DCM, "Tracking Unique Identifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cc70b867-32f5-4e46-aafc-6b8f9d0de090">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ae34cf1e-1f42-4f16-99c9-ab9ad6234a8d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0f122bd-cf31-413e-893f-166a3d9a537b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c54c8c1-09f4-4a16-9006-a14f147d192a">$TrackingUID</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aca4cce5-441a-41c7-8d9f-c6cf1c23f043">3a</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4671f6f3-8f55-44bd-8b94-3d953ec2442e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29c85a21-23f7-4b40-8e74-cc22cd109d84">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_12c42bb5-7495-43c0-9706-0c722b3a0dc9">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac92200e-fb14-4517-9c2e-fc8cfb881cdc">EV <link xl:href="http://snomed.info/id/276214006" xl:show="new">(276214006, SCT, "Finding category")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_09614a32-7351-4ec2-bd12-6d72ecd659ba">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_88a554fe-54fa-420a-9481-6253f6f7829e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11f53866-9fe7-4d93-899b-df5e0a1b9921"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_41efdaec-1504-4305-a97f-5126e1971199">$FindingCategory</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8764a019-df85-47b1-bc38-1eeac537d7ac">3b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da585f62-2c12-4888-8125-d7a6c7e62263">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4ac1cac-ee86-4a86-865a-8137ebe1bd95">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dfd59901-9eaf-4594-86b4-d9df83d9972f">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_360e0c20-ef41-4422-9ab8-8263e4d3ae4a">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_07010f85-ccd1-4d84-bd56-83e480764378">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_81d25198-eea2-4721-bfea-3acb1f82456f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46aabbca-0393-4351-9e8d-723c2187ff69"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9dc7e2f2-b912-4670-8550-e10372be23c2">$FindingType</para>
                            </td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1">
                                <para xml:id="para_ec816b00-2bbf-4e9a-a729-6c2563b25135">3c</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_53d9f483-05bc-473d-9729-30abe88771a6">&gt;</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_ac2e31c3-79c7-4311-9f39-d601da51e09b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_00d7dcee-a829-48f9-be89-57c073497cce">CODE</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_5a96f36a-6706-46a2-b5c5-88f0de5adf09">EV <link linkend="DCM_130400" xrefstyle="select: nopage">(130400, DCM, "Geometric purpose of region")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1">
                                <para xml:id="para_124dd689-9d01-4d90-aed8-72524cdd2bfd">1</para>
                            </td>
                            <td align="center" colspan="1">
                                <para xml:id="para_96f48934-c179-4085-9b02-50a32669d76b">U</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_890d613c-4d02-4ef5-9bb5-c34464f943f2"/>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_a719214a-ab1c-4064-8bc4-73f0a6fb02b3">B<xref linkend="sect_CID_219" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f0d68d2-82ac-49e8-8f78-a6a91ac1e997">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d34ec998-aa1b-42f3-b5b4-f8c4bcd605b4">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e697a73-2ec2-4351-b9f3-3272be1ae0f8">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2d05d121-c966-470b-9838-b9bf5698ecaa">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ebf6108-83ee-4b2b-852b-47ed3ebcd3ba">D<xref linkend="sect_TID_1502" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d5291498-e131-4d9d-b957-fd33e5acb801">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7a92bc73-c5b1-4939-b0a5-db467da5ee07">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf85aa02-0481-499d-a3fb-23b62278359e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88c34109-7f62-4808-9af0-37c9e208e47a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_409f6e6d-f887-4f49-8b11-989188aedec1">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee6fd942-0371-4fde-9638-f2a8e67e6fcb">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_208032d8-b7e8-4af0-bd71-840b23278e24">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b68aa0a9-d0b1-475c-9630-fbbd48dc581d">SCOORD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aeb2a487-642c-44a7-8b45-d6d50adb365f">EV <link linkend="DCM_111030" xrefstyle="select: nopage">(111030, DCM, "Image Region")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ae8bf884-64d7-40bc-97dc-e6a4d7a6db83">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c2d8f97e-e24e-4591-b38a-f69d71824f03">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7056160c-74ff-4830-8ffe-c048ab696afc">XOR Rows 7, 7b, 8b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9fc59e52-3212-40a3-aea4-5b89635d1073">GRAPHIC TYPE = not {MULTIPOINT}</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2fd976b5-86d6-402a-a25e-e1d3ad8c71df">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b61af4ca-9a37-482f-8823-7f1b73b7eaeb">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61538b3d-d790-4596-b395-7e7f083e18c0">SELECTED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d898cf3-65ee-46c1-a19e-17ebe5d0def2">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a46a4c1-9af4-401e-80fb-9f9265a270db"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_584a39b5-760d-4662-8675-3367175e20bf">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_45965ebc-e1d3-40dd-b11f-72e8e7169770">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8337874b-0930-408d-a290-518ba3f2656c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6bf3b656-2906-4808-a9d0-762fee69b54c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d5a0bc4-a020-44ab-a211-f17a9fa83246">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dafa9592-2b76-411a-9dfb-b07bf3f4bdb5">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37c5f744-ec7b-4ecc-96c5-ce5e33d14f03">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e873d36-d3af-4f1c-9fd1-79cc437ae752">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0840dc73-1210-4877-a6fe-5c287e00c5b6">EV <link linkend="DCM_121214" xrefstyle="select: nopage">(121214, DCM, "Referenced Segmentation Frame")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3c544407-674c-4954-98c4-405cae664c59">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2f37e245-08d0-46b3-b446-4b1b9955370b">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b26463d-cb66-40bc-a179-c245a1aa6541">XOR Rows 5, 7b, 8b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24dd541b-fcbc-4cc8-9364-0a8fee6741cd">Reference shall be to a Segmentation Image, with a single value specified in Referenced Segment Number (0062,000B).</para>
                                <para xml:id="para_5995e360-45b7-4da1-9a36-7d44c42edb84">For references to tiled Segmentation Images, one or more values shall be specified in Referenced Frame Number (0008,1160), unless all frames in the referenced Segmentation Image are selected and there is only a single Segment, in which case Referenced Frame Number (0008,1160) will be absent. The referenced tiles shall all be in the same plane.</para>
                                <para xml:id="para_ef39be61-c197-4e5b-9a06-24d364045741">For references to non-tiled Segmentation Images, a single value shall be specified in Referenced Frame Number (0008,1160), unless there is only one frame in the referenced Segmentation Image, in which case Referenced Frame Number (0008,1160) will be absent.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f9c960f-d44e-4440-9762-3fbf05b80de1">7b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e882976-fa30-4757-8905-259512b4b924">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_558c96de-5729-4bc5-950f-56bd85dd47b0">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a723f9c-a6d6-4e75-b433-68c8c2724875">SCOORD3D</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac4f927a-6af9-48a5-bb6c-cf20f9ffaa8e">EV <link linkend="DCM_111030" xrefstyle="select: nopage">(111030, DCM, "Image Region")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_29311599-70ad-48b6-8b6f-c6177681c7d0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6208f3a4-b6a6-43c0-b1f8-eb799bb5d2fa">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17e1358f-3b6b-4611-9676-982717a42680">XOR Rows 5, 7, 8b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61b5c76f-1055-46bd-832f-9f5f1db0bf8d">GRAPHIC TYPE = not {MULTIPOINT, POLYLINE or ELLIPSOID}</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd6f4e6d-bfaf-469c-a569-678a3e28a45c">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9eb47db7-af21-475d-9bd6-a2c3f16dfdde">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e07e9e71-53c6-4d5a-899e-6fd1ae56665b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff3d0c74-1592-4dfc-bc58-b7beb4433ffb">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97ea6a5d-9ccb-4e07-b9e6-00d50cf38213">EV <link linkend="DCM_121233" xrefstyle="select: nopage">(121233, DCM, "Source image for segmentation")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ffa90db0-e98e-4257-ab76-0e13a9c0376f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cb697351-58d1-4567-ad0e-5ddcd6258d27">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb70c3c6-b10e-410f-a1b4-71dce1ecdad9">IFF Row 7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8d18206-d68b-49d1-8f4a-863567c5f41d"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ea82210-3c64-43bf-aac5-1af720196ee7">8b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5f1b492-58a0-4f45-9879-7b234a84b364">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_579783d7-e532-4442-a50c-17925633046d">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef51c5ff-9a74-4976-810b-447f94ef0724">COMPOSITE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf76fa15-fe33-4fed-9682-ae784b730b84">EV <link linkend="DCM_130488" xrefstyle="select: nopage">(130488, DCM, "Region in Space")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d17a03b3-fbf5-4c59-9119-19ece4217f87">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f7a7c643-956b-408d-8661-e82b6ebc64ac">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0407be5e-9c2a-4a21-8da8-f2b17d0dd5cf">XOR Rows 5, 7, 7b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9f812d5-b845-40ff-b3bd-1c73cb933744">Reference shall be to an Instance of the RT Structure Set Storage SOP Class.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd5f5240-d71a-4019-b555-ea96643e4eed">8c</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70a81489-8e21-4cb0-86bf-52e37005e8ee">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70a00bba-5aa8-4698-81c7-d6dbea8044c6">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6cf8fd49-e57e-4d47-a101-8dc194242a9a">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31348355-bdb2-4997-9998-49296f89eadf">EV <link linkend="DCM_130489" xrefstyle="select: nopage">(130489, DCM, "Referenced Region of Interest Identifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dc5556b6-e6c2-4b5d-9964-ecd6011ebb72">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c9bbefb-b101-45bb-9fd0-d0df75eebdd5">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca66169e-8e9a-4dbe-b411-b49c1dac4344"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93e54f29-08fe-448f-9792-be87f84517b7">Shall be the value of ROI Number (3006,0022) within the single referenced Item of Structure Set ROI Sequence (3006,0020) of the referenced Instance of the RT Structure Set Storage SOP Class.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_313a151c-67cd-49b7-846e-4d5a3e2c75b6">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4786b290-a3b9-480b-82d8-61da51f69902">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e173176-b24a-43ba-8a9d-140b3018ae55">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0cbcfa96-4ad8-476e-b1e8-383174d68dc5">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d6c0f3f0-30c4-4ecf-a4bb-6e5a1c86e9e3">EV <link linkend="DCM_121200" xrefstyle="select: nopage">(121200, DCM, "Illustration of ROI")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ea521b1d-ad15-4728-a26d-849b43104bb3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0d9737a8-771b-4229-a641-b9f86c4feee8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a573c035-ba51-4957-8247-657d5af5f258"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b989e7e5-94ac-4903-9449-18b04d1fe108"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cba23934-2c47-44b6-b834-d7ff6809e9ea">9b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f83a89d7-f094-41c9-820d-76cc398c9fc0">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8c2a72c-7db8-4792-ae87-823523fbfd77">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5759476-134c-4025-9859-b6b4bc1d5f09">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb85c5a6-5724-4504-9675-1737077a473f">EV <link linkend="DCM_130401" xrefstyle="select: nopage">(130401, DCM, "Visual explanation")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d3e88864-b76c-4b1c-9212-e423a7aa801b">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c2fbb35d-c8b0-4183-b814-9c2ff56cd55b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2d95ee3-e445-4738-af9e-afa87b21e28d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6505d173-ea2f-47a7-ba7c-55faab18d15b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed99ed8f-5812-4207-be2e-ac6586ee4667">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_046533bc-8863-4fd7-a14f-642334b42b94">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61769706-ae87-40f2-927d-77450a617980">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f95c9649-525a-47c8-9944-441781b1347e">COMPOSITE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52f6fcf1-9602-4df6-9456-549628536aa5">EV <link linkend="DCM_126100" xrefstyle="select: nopage">(126100, DCM, "Real World Value Map used for measurement")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cb90f7af-88ac-4016-82aa-a846603f7103">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0884c679-b70d-4a60-84be-71f1c936781d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3321af56-c75d-4230-a308-db95c12a3366"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dfbc48a7-79d2-496c-af44-3032222b4a7a">SOP Class UID shall be Real World Value Mapping Storage ("1.2.840.10008.5.1.4.1.1.67")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36d95f7b-6c73-43b2-b6ee-9223eb679870">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b701d26-39dd-458d-b6a9-8e15b0faf6bc">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1292851a-62f8-4527-8bad-63dc83e73420">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5af635b-0119-4333-98ce-ad385c1a9d06">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79c684a2-36cd-45d1-a78c-1fb0a09108b2">D<xref linkend="sect_TID_1419" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_586d5703-c3b8-4005-b6f2-610ac2adcd49">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9a078511-3531-4319-a3d9-d098eb49e2db">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_185e14c0-ef5e-4430-a4e2-cd134bb822d7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e7e2db6-dbbe-4010-85ee-9306c087feb5">$Measurement = $Measurement</para>
                                <para xml:id="para_f5b049f1-102c-4545-8b23-e51c438d4501">$Units = $Units</para>
                                <para xml:id="para_66abacbc-dd6f-4651-8c5f-79931a4a1604">$ModType = $ModType</para>
                                <para xml:id="para_89afda40-4ea1-469e-aa5c-5a3d611fa73d">$ModValue = $ModValue</para>
                                <para xml:id="para_c175ab37-acd4-41e3-ab20-0a64efb018ad">$Method = $Method</para>
                                <para xml:id="para_2a8d0687-d4c9-442a-b78b-5cf172a857ab">$Derivation = $Derivation</para>
                                <para xml:id="para_0e54d21e-15f0-4992-b014-63075c10967d">$TargetSite = $TargetSite</para>
                                <para xml:id="para_be52a210-33cb-4936-ae8d-3f4205f466c7">$TargetSiteMod = $TargetSiteMod</para>
                                <para xml:id="para_6e7e776e-ce39-4d5a-95c1-59d47e80eeee">$Equation = $Equation</para>
                                <para xml:id="para_cabc58f5-afd7-4d36-854e-28d8c7d8af38">$RefAuthority = $RefAuthority</para>
                                <para xml:id="para_aca8ea70-8fb5-443f-8cbd-88f813681ded">$RangeAuthority = $RangeAuthority</para>
                                <para xml:id="para_c6a80332-9fa9-4b6f-abde-8c3a5e209bd7">$DerivationParameter = $DerivationParameter</para>
                                <para xml:id="para_c21df87c-f805-4dd3-b60b-1c5a828f4fdb">$DerivationParameterUnits = $DerivationParameterUnits</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4caebf43-3ad5-48d9-af9f-ed2a476c7b2c">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_49e72c1a-4079-4bfa-88ac-ad228fa0e879">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea580061-39b3-465f-99b5-3a7dded15a97">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82c8077c-40c2-4fa6-866d-4046d268c8d8">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3388ed3e-3830-4a2b-8207-3dfd497ae977">$QualType</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e8a92d0b-1734-4ccf-834c-c3cb93a8c3fc">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f8c50519-92b9-4bda-88cc-1e52bbdb4e41">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_575d0ac3-3ed6-4fd8-8fc2-7e1af7ff03ec"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_061a603e-0fea-4f10-9237-dc5704af7a4c">$QualValue</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_958173f2-425e-437c-b243-b47bfb4488ba">12b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee1ec32a-222a-4691-b622-a7fefacfa051">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8786df7-0055-4a81-8406-5444ee467b00">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b5c6e6e-479c-4513-b864-b9722d041785">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d52abf26-14b6-4309-9f54-380418eaed32">$QualModType</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_129b342e-0567-4197-8dbb-d10e295253a8">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_72d2d273-576f-4a54-9ae0-0dc0dbef13b4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d8f1ffa-7375-4e4e-bf67-319f3b1c2ea9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8100c43c-978d-469e-8c16-a4390a4ea9a1">$QualModValue</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a284ad5-0379-4e48-bdfb-935fe207e896">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f196fad-8ce5-4b00-b3e9-0bbc042a5078">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6adbf8e7-442a-4620-b275-a5b34eb2588c">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65e0c51c-c749-4d27-83f8-efbfe1ffefde">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03aa607e-19a2-42b9-a606-c8581a633751">$QualType</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c12f8242-a497-480e-b036-2c52b60444da">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5ebab0ff-fde9-4176-b1b2-0e9611b5d9a0">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_637039fb-753c-4a98-a7b5-25c573296787"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3fbbf641-5108-4c3c-87bb-af431edfe500"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_12f34dea-c5d4-4127-b3fd-5f2adff0a8ef">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65e892e1-ba0e-48e9-943a-c83cbb9853e3">Row 1b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dbf64cb0-8a44-4981-95d9-33e71bf19d91">Identifies the session during which the measurements were made. The NCI Thesaurus definition is "time, period, or term devoted to some activity".</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_676d3cf2-7665-45d7-8a2e-ead357a99bd7">Rows 2, 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48b5a5c1-401f-4c09-876b-7abed9278926">The Tracking Identifier and Tracking Unique Identifier are defined as a text label or unique identifier (respectively) used for tracking a finding or feature, potentially across multiple reporting objects, over time. As such, they are distinct from the Observation UID (0040,A171), which is unique identifier of the specific Content Item and its subsidiary Content Items that constitute an individual observation, and would be different for different observations on different occasions of the same finding or feature. The values of these Content Items shall match the corresponding values of Tracking ID (0062,0020) and Tracking UID (0062,0021), if present, in the corresponding Segment of any Segmentation instance referenced in Row 7.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e17b68a-7939-456c-8b99-579be487c98d">Rows 3a, 3b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0f5afd6-90cf-424c-9ab1-9ca35f66c302">The category and type of the finding describe whatever entity (finding or feature) is identified by Rows 2 and 3. E.g., a finding might be a lesion, a tumor, or a reference region (as distinct from its anatomical location, which is encoded in a different Content Item (Finding Site). When spatial localization is by reference to a Segmentation, the category and type may correspond to the values of Segmented Property Category Code Sequence (0062,0003) and Segmented Property Type Code Sequence (0062,000F), respectively. See also <xref linkend="sect_CID_7150" xrefstyle="select: labelnumber quotedtitle nopage"/>.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c53d2751-c9e1-4f42-b8cb-2db8762be074">Row 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91888c98-d413-40db-985e-f81f83c2ebb0">To describe an infinitely small area, such as the center of a lesion, a Graphic Type of POINT may be used.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d031d92-603c-455e-ad67-84cef5b15eb1">Row 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e73c4cd1-660d-4180-b7c5-b2bae6831c30">
                                    <link xl:href="http://snomed.info/id/260753009" xl:show="new">(260753009, SCT, "Source")</link> may be used as a generic Concept Name when there is a desire to avoid having an anonymous (unnamed) Content Item.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2babd6ee-8440-4df7-87f8-8cfc79a2f2e2">Row 7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48197dd3-b070-41ae-b65f-61265a57f1b3">Referenced Frame Number (0008,1160) and Referenced Segment Number (0062,000B) are Attributes of the IMAGE Content Item.</para>
                                <para xml:id="para_6dab3616-4bba-44c5-92fa-571941f4ada2">If the Referenced Segmentation SOP Instance has Segmentation Type (0062,0001) value BINARY, it identifies the area of defined (measured) region of interest by pixel values in the referenced frame with value 1. For Segmentation Type value FRACTIONAL, the area is computed by an implementation dependent method.</para>
                                <para xml:id="para_f5322076-0cc8-427a-ab7b-a6f22534be34">Referenced Frame Number (0008,1160) may reference multiple frames in the same plane for tiled Segmentation Images (such as segmentations of Whole Slide Microscopy images).</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d0586d2-2dd6-4a95-a15a-520170d8f32c">Row 7b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30254e85-71f3-44fe-b526-84ca904c9817">The area may be defined independently of an image by reference to 3D coordinates in any type of DICOM Reference Coordinate System, whether it be patient-relative (Patient Based Coordinate System), volume-relative (including acquired and presentation state volumes), or whole slide relative (Slide Coordinate System).</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1ded33a-a26f-4d96-8c25-411ba89d6eed">Row 8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_983898e7-403a-43eb-ba65-ada0710d991d">Identifies the source image that was segmented to identify the ROI, and whose properties are described in this container.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cdaa8d8c-356e-46d4-b27b-b7d1b3a63aaa">Rows 8b, 8c</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_15afcdd1-4736-44c6-af59-28ae6d571740">A reference to a single ROI that defines a planar ROI, within an RT Structure Set.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da642821-8bef-4b68-b732-fa0a6c7208c4">Row 9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d9345d8-365c-4575-97af-38086b027daf">This referenced image may contain a "screen shot" illustrating a rendered version of the ROI.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7a8d0e72-e202-4c2a-8f64-baf63bb60dfa">Row 9b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eae6a3f3-19a6-4483-831f-7e24c7e9af45">This referenced image may contain a visual explanation of how an algorithm produces its results, and may be a "screen shot" of the explanation already superimposed on the source image (e.g., a "heat map"), or a parametric map intended to be superimposed on the source image by the receiving application. The type of image and the type of visual explanation is described in the referenced image's own metadata. More than one referenced image may be present, if there is more than one type of visual explanation, or it needs to span more than one single-frame image.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca234623-cf4a-4115-99f0-0ce749fdcf0e">Row 10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca61634c-a61c-4563-918b-4c8cb5a495f1">The reference to an RWV in Row 10 allows measurements to be made in units that differ from the stored pixel values in the images referenced elsewhere in the Template. E.g., for a PET SUVbw measurement, the mapping from activity/concentration units in the referenced image that was used (and which may be reused for measurements in the future) may be encoded in a referenced RWV instance. This reference applies to any measurements in included Templates, unless overridden).</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b1c0c52-9d1e-4715-b59d-5a79f0d81d97">Row 11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b069227-7302-4e57-bcf3-e28eb6642c39">Measurements may be omitted, for example if it is desired to describe only the location of a finding or to provide categorical information about it.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ec6d4c9-c382-4726-9f3a-391cf8b8d85a">Rows 12, 12b, 13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c591e26-004c-45e4-9f77-7552603762a3">Allows encoding a flat list of name-value pairs that are coded questions with coded or text answers, for example, to record categorical observations related to the subject of the measurement group. A single level of coded modifiers may be present.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1411" status="3" xml:id="sect_TID_1411">
                <title>Volumetric ROI Measurements and Qualitative Evaluations</title>
                <para xml:id="para_cbcf130c-59d0-43ea-b71c-7f7d5b19c70b">This Template provides a general structure to report measurements for some metric, e.g., density, flow, or concentration, and/or qualitative evaluations, over a volumetric region of interest in a set of images or a Frame of Reference. The volumetric ROI may be specified by a set of SCOORDs on an image set representing a volume, by a volumetric Segmentation Image, by a volume defined in a Surface Segmentation, by a set of SCOORD3Ds defining a volume relative to a 3D Frame of Reference, or by a reference to an ROI defined in a radiotherapy Structure Set.</para>
                <table frame="box" label="TID 1411" rules="all" xml:id="table_TID_1411_Parameters">
                    <caption>Parameters</caption>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_12bc1135-1528-4f57-af74-985a2a957dcc">$Measurement</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ef5c685-327f-43bc-ab4d-385b2bfdc3cd">Coded term or Context Group for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d7a731b2-e3fd-445a-94f4-5a2172c21690">$Units</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5b7fbd2-1d1c-4b5b-8b24-cba9d5c7aada">Units for the measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_44356a51-dee4-49b4-b227-9bd1a1feed9d">$ModType</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c474b01a-cd40-48f3-8b9f-deb394794e0e">Modifier Name for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6be29a35-b833-4b87-86ec-097d29ec2714">$ModValue</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_524bb943-1a2e-4fc7-9538-c148fab4f464">Modifier Value for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c6aaffb8-b2db-4827-b870-a5e42e8925ae">$Method</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_231dbb0d-9ea5-4420-b27c-26b1e00bcdfb">Value for Measurement Method</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f78663f5-2a3f-46c4-9c4b-0829bf992da1">$Derivation</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84631364-571a-4fe1-bc9b-d699011b7ac2">Value for Measurement Derivation</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0c7f7a7f-6b48-4f09-9224-e80219781c71">$TargetSite</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3984613c-4e64-47e3-8a95-f7cec58c0eed">Value for Anatomic Location of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_64102ce8-91c0-479c-8efd-f752272abf26">$TargetSiteMod</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75b61bab-f4cc-4286-8fec-2685b35da3f5">Modifier Value for Anatomic Location of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca4dce4a-80de-4f67-a774-1dac9532ef6e">$Equation</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c43b34df-9289-4b72-9a7b-1b0d685decb6">Coded term or Context Group for the equation or table from which the measurement was derived or computed</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b8eace8-1811-4299-b969-7a8a2803b67e">$RefAuthority</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_426845ec-e9b5-417c-b405-911e46ca72dd">Bibliographic reference or authority for statistical properties of a reference population</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_49d8f23a-625f-412f-8e53-b3789b913c4f">$RangeAuthority</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_196cfa96-8a92-4c61-8540-c28e0da90efb">Bibliographic reference or authority for the normal range of the measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_47add769-ec18-4492-9484-0d60511d2c39">$DerivationParameter</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_12217a06-0aaf-44ff-99fc-dc380a8481dc">Coded term or Context Group for Concept Name of a derivation parameter</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7178e9d7-bbbc-4329-bf71-cca34a1af9f8">$DerivationParameterUnits</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe60ac5a-9182-4db6-8c05-1bc1ba5f1b9e">Units of derivation parameter</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_feca7758-4cea-4a58-8674-b487429daa16">$QualType</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f5bdd92-027a-45a6-8a98-dde2ccffc5c4">Evaluations encoded with code or text responses</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b47700b-a1a3-4b5d-883b-bdeb91238737">$QualValue</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b526a21a-38be-4aa1-ada3-00a764cf2b4d">Value of evaluations encoded with code responses</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25d119db-9ecf-474e-82fd-a28a45c26061">$QualModType</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_792e163e-8a68-42de-84c5-29b4162e91c4">Modifier Name of evaluations encoded with code or text responses</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b6a3ae5-2ae2-41c6-88b6-8336e96ee5fd">$QualModValue</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f78dd308-6379-4f56-b791-176ff3a2dbce">Modifier Value of evaluations encoded with code or text responses</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93df89ea-1f42-4a83-a874-833e38fab83e">$FindingCategory</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e46d3c30-a4d3-4d98-b3f3-481f35a419ff">Category of the finding</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0fd4697-f42d-4c3f-b519-1710f342e862">$FindingType</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b08d0544-14c8-49fe-987b-b61c35159355">Type of the finding</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d52ea22e-c4fe-428d-a0b1-9dfc3280f0a1">$TrackingID</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05615286-cbfe-4c5c-a60c-bc8428afa2c3">Value for Tracking Identifier</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be1c7712-08ee-47e6-a7c8-6057825f5eb3">$TrackingUID</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd412c1c-a93f-4f77-bb00-e9354b1464dd">Value for Tracking Unique Identifier</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_551db35d-f22f-48a3-92e3-4ae094e62e5c">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_8566cfef-414d-4eda-9dfa-dca833e126d3">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_062dbae5-c594-45ee-ba41-e42b75d949fc">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1411" rules="all" xml:id="table_TID_1411">
                    <caption>Volumetric ROI Measurements and Qualitative Evaluations</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_87e5605c-30ef-40ab-9e54-e5a160ac1e4c"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b792ca18-4b6b-4780-8c36-f0872b923a62">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4548b0a2-dafe-4ffe-b5ff-6f4b746b5f37">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0b48ed64-9046-488b-aaab-3e437093e793">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_037bfccf-fcbf-4646-a614-7d3edd7495e1">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a4416f1f-b2da-48e2-afc1-6d1916588c9f">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8d7ea4d1-7d0f-4df2-9d64-44c4151c48a8">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9c44f7e5-e932-432b-ae62-83dc4ba5d58f">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6daad6dd-d304-4d58-b580-ab3f55ee692f">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0bd991eb-9642-42a0-9c93-87848af2ac98">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9797c7cc-b481-4eec-8d93-ae08fb873fac"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eab96362-2bfa-41eb-9637-0bf9efdfb87c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0bcea660-1791-4428-9783-86bf458b9f04">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2b51594-f8ef-4ee7-8448-f3dfaa51b3a9">EV <link linkend="DCM_125007" xrefstyle="select: nopage">(125007, DCM, "Measurement Group")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b8912904-0922-489a-85ba-f80c0b80db5e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_06cf9952-1268-4f7b-a9fe-915d8d26cd3c">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91c8a03f-d2c8-4731-b118-5c6353303797"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac09d88a-4385-4f34-9717-b507f6b6dc0e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_877bb76f-4c64-41b3-bfab-0eea84a49504">1b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b700d29-3e4b-4bd9-bd54-da1cbfda3b27">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_939f9e7a-0ff4-45cd-be67-8501659ec0a1">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c2a24f6-d223-4764-9bc5-f445a2517571">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4e1a46f-5ec2-439f-8ac6-82a7ec89529f">EV <link xl:href="http://evsexplore.semantics.cancer.gov/evsexplore/concept/ncit/C67447" xl:show="new">(C67447, NCIt, "Activity Session")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1bf8ef93-0eec-4a8d-a65d-95d52d0bb5a7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0ecb62e6-4ce5-4d1a-9602-fd6d1a6f2b53">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e1259d1-10b4-4705-822c-766dcb020a35"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eda1d8ee-c6de-417f-ab61-06a118c97fd2"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d49c3385-7143-4f1e-886b-cf30c0abd1f0">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5b3c6c4-4b54-472d-9fbc-5c635dcd4095">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a07c1f75-2c5e-468f-8960-78711a160d25">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5daab99c-8639-4758-b4d4-45b668e3a266">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de5dafa0-930b-4d3f-bea8-f4bd3e516508">DT <link linkend="DCM_112039" xrefstyle="select: nopage">(112039, DCM, "Tracking Identifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_42cf601f-20d8-4e98-8dec-c59791a1f3cd">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1f842512-a08f-4e30-8304-582258540163">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df9c2b6f-d5ae-4a7a-a301-e831d914af29"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b09d7f6-8a5e-447f-ad4f-60e30d1068cb">$TrackingID</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf74cec9-f15f-438d-9dd4-a885feb024c1">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0559edc8-3c87-43df-add8-def43d9014b7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81a22fff-1270-40ec-882c-448005cc4a4f">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5ce8862-5514-4f83-945e-5b8e56055553">UIDREF</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea3123b4-9fae-472b-b922-d585a7764e0a">EV <link linkend="DCM_112040" xrefstyle="select: nopage">(112040, DCM, "Tracking Unique Identifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_748cfd62-5864-4587-aa83-af2a2740a5cb">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c36bd25f-4297-4bb2-a529-31cdd7442342">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc703b24-b317-424a-999e-d746c19d966e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91566137-769b-4552-bc4a-be670b7d455d">$TrackingUID</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21a31ca8-d4cb-4487-82ef-11366e151a06">3a</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5f6fb6c-0519-4cf7-bf13-409ce2efbd78">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea3c2dbb-97a7-4116-9aea-a03b40e75f95">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c99b44f-cf60-4c3d-a0aa-8eeea109175b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce54e23e-b80e-4a34-bcdf-4c0012680daf">EV <link xl:href="http://snomed.info/id/276214006" xl:show="new">(276214006, SCT, "Finding category")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bd877c1c-b3b9-4b68-ac56-5e10b923f6c4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cae41d9d-e59a-46f5-b606-141d1bf60b19">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16197223-cd30-4482-b11f-af2186f503aa"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ce36d67-2742-450f-b302-d4c88dc531d5">$FindingCategory</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_920b74c4-855e-47b7-84ce-0920ae970626">3b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fcf02cf5-a072-4884-a248-4fe807755965">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9dbb8ab4-5274-4fe3-964f-d75547c0548b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5024bb8e-45db-468d-8e23-91ebb51db0f3">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a12b91cd-78a7-4cea-80bf-f9da3f99f2ac">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_624ea517-02f8-46d1-8020-204497b41eb8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_107515d3-d48d-46bc-822b-4ac1adf5269e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5064a512-9d40-4dab-ba88-e5b4ff674e97"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b1655ce-a87e-481f-b815-42f7ee423074">$FindingType</para>
                            </td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1">
                                <para xml:id="para_27a9c34a-fcae-4ed8-8732-afb5e81e5a32">3c</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_d4807728-76ac-43df-b946-1135aa8eff4a">&gt;</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_8a82726e-ef2a-4c3c-9e63-df33c70ca466">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_e248355d-0f8e-4ed7-9419-3f6bd509c337">CODE</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_c7eff386-fd52-4799-8e97-ecea7805338c">EV <link linkend="DCM_130400" xrefstyle="select: nopage">(130400, DCM, "Geometric purpose of region")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1">
                                <para xml:id="para_4475a4af-fca2-40bb-92bb-335400817776">1</para>
                            </td>
                            <td align="center" colspan="1">
                                <para xml:id="para_ef0bb4c3-bb91-4929-98a9-5aa160f8390d">U</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_600181dd-395e-410b-b039-a89e7984ca3d"/>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_c23c0a68-48b6-40e9-ae52-b1312ef836dd">B<xref linkend="sect_CID_219" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c896f4d3-491f-4813-9957-5a4f30ec92aa">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f10bed2-2f52-4dc5-bdfc-03f53764ad9a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c7a8be1-86e9-40b8-815a-de006fdc48a8">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3eb73dfc-064e-4c8a-b4de-9c4f29f40bf9">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30fb9e84-8776-4052-b66a-e926eb7241fc">D<xref linkend="sect_TID_1502" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4485b273-e2a9-453d-b39a-870b1c6781f0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c38b34b8-17b3-496b-b21f-3a5c01afc317">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dda7c866-72a1-4a7e-b4a4-c6ad4ae6506a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fbbd460b-599b-468a-aca4-b9fa0abf34ad"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a7f801e-885f-430a-bd16-b30d110a1688">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7af8c31f-2643-458d-8e14-dd1f3255bb05">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8a1fdf0-a434-47d9-801f-d653ef323489">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1770bfca-c1c0-4d94-afef-585287c8fab9">SCOORD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5da4d3d-0d8e-4e1d-89ad-b0ff686e2821">EV <link linkend="DCM_111030" xrefstyle="select: nopage">(111030, DCM, "Image Region")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ad1a6260-eebb-4362-bb5d-36a4c358709c">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1433ce9d-9be0-4b8b-9cea-fac6e2457283">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d7c9f261-862f-4f4e-af48-c4991bad9403">XOR Rows 7, 10, 12b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a4e4c48-d4b8-4fd8-9916-f7c7dd6c68bf">GRAPHIC TYPE = not {MULTIPOINT}</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1922085b-ae2d-417f-884e-4ad99df2cfd1">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a2f1b3d-4d96-46a7-9e71-8c38f1923cc6">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_162b8ae0-ceab-44ad-9e45-7e2d52b8a450">SELECTED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc1348d7-32ba-4ebc-b33f-da5ab5244b1b">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de799c4a-6157-4d21-b70f-5ceabe82e778"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f685cd2d-5961-43c7-b692-a8b66e591af8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_26d503ce-2255-48b0-bc65-01ba0499077f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62913662-81a3-4c89-baa3-c8f9401ddb60"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3295597b-5673-4db5-8f89-e1635d935dce"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad9a7ba2-af63-48fb-84d3-00c124017027">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99b8c5b5-8655-41ee-86e3-092c9881c82d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3d526cd-9556-4905-a0be-00c13011cacb">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae357b28-4114-42e0-8fcd-29e6cef183f3">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a692999-4664-4d03-b6ee-3675f3f580c9">EV <link linkend="DCM_121191" xrefstyle="select: nopage">(121191, DCM, "Referenced Segment")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d7b8acd-9ea7-4389-939a-37b5b8127b76">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6904a646-c0dd-4765-9d3a-0efaa128d777">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1c1ce88-c21b-4e66-acf8-2d0862590ad2">XOR Rows 5, 10, 12b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e016cb9-0c46-4f8b-ac6b-0d5b36b83d8f">Reference shall be to a Segmentation Image or Surface Segmentation object, with a single value specified in Referenced Segment Number</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4f3a8f6-2d92-49e9-ab18-d1750c31f1cb">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5942475-caf5-4b5b-8ef1-572ab8b05778">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08d967de-4460-4233-ad43-542afda76c50">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_953ef38b-a49f-4d4e-a791-e54c13480fe6">SCOORD3D</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1082097-4877-4b87-be85-459ec1f45e57">EV <link linkend="DCM_121231" xrefstyle="select: nopage">(121231, DCM, "Volume Surface")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_783866ce-63e0-4021-85c3-bce5be35e4cc">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f19a0a1f-c92a-45ed-b6b6-c97eced455e1">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ee17874-ef57-4cc0-bc0d-9ba6d1365733">XOR Rows 5, 7, 12b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0eabd745-2fbb-4d51-906c-a6872c0c3631">If one item, GRAPHIC TYPE = {ELLIPSOID or POINT}</para>
                                <para xml:id="para_94e71819-f1b8-4a7b-8194-f8fcf7ee244d">If more than one item, GRAPHIC TYPE = {POLYGON or ELLIPSE}</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51ce42d9-348f-4b22-a1f3-c4eeeae13aea">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fbfdbb5f-2399-48cd-8a37-27cfd3ac93e0">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ef769a4-b036-488a-9617-cbe524d65743">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_582c8232-dcd5-4aab-813e-3258dbc8f13c">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5041208f-c5d5-4906-87d1-92f4610d7f08">EV <link linkend="DCM_121233" xrefstyle="select: nopage">(121233, DCM, "Source image for segmentation")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6e888005-191c-4f37-b69d-091f05b75823">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb51dcec-c372-4680-82e9-f14a4617538d">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba907fb4-8b79-43d3-99fd-ab6d5d47c208">XOR Row 12 and IFF (Row 7 or Row 10)</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17aefa54-5d49-42ca-b9e7-7e736ebbdcb0"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4330498d-5af9-47c5-8d78-bb4b0e579616">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7513186f-31e6-40c3-b827-b4ea1a357362">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b970e94e-0c56-4720-96dd-6aa4ba1b692f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_277a3bf0-2f46-4870-9fad-39c31f5ce53b">UIDREF</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72cde9df-be57-4d02-829c-edb25d574bb5">EV <link linkend="DCM_121232" xrefstyle="select: nopage">(121232, DCM, "Source series for segmentation")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0c538e29-5818-47d8-8bae-7a89ce13b8e3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_41bc29f5-d975-4822-ab35-33cc8a34c59f">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f394ce81-6558-4814-8ed0-59cf7e54df6c">XOR Row 11 and IFF (Row 7 or Row 10)</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87e310ad-ee4f-4cbd-8478-4f33ad28764a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_026142bd-1b96-43b3-9fa7-5ef906f2e44e">12b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e0c211e-23fa-4bc4-89b1-8e2d974f0b80">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04c479b3-8c48-4a0f-8310-b96e2eb3edb3">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_229ae1b0-d2ef-4e07-a0ea-2e8300149966">COMPOSITE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37eb8fd6-d6f3-4a43-af13-26dff45fc87b">EV <link linkend="DCM_130488" xrefstyle="select: nopage">(130488, DCM, "Region in Space")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4bde3c3c-797b-45a8-8868-d92d7b8f5dfe">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_357916d4-ba30-46f4-a80d-2ea071ebf7bb">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b7aa33a-4e13-4f8b-be70-7934d3981840">XOR Rows 5, 7, 10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51c774e1-b1af-48f1-86f9-64de98cd96c4">Reference shall be to an Instance of the RT Structure Set Storage SOP Class.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4cc6c43-857f-4eae-9830-556b1b3a0b42">12c</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df8e6f35-cf75-4f20-8b86-3801f7ff2b91">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d72e83e-ab41-447d-9cda-cb691df53bad">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_34521067-a172-4ade-9c49-5e155a53a14f">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0c28a9bb-13d4-4819-849c-1f8374f179e0">EV <link linkend="DCM_130489" xrefstyle="select: nopage">(130489, DCM, "Referenced Region of Interest Identifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e1370b14-71c0-4814-b84a-83a5819f59cf">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e49c9696-fce1-499d-9225-2917c5f456a8">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7e4168e-34dd-4e70-b928-67683d7c202e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06f4fe38-f432-414d-a359-ff91b3050c3c">Shall be the value of ROI Number (3006,0022) within the single referenced Item of Structure Set ROI Sequence (3006,0020) of the referenced Instance of the RT Structure Set Storage SOP Class.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48d6906f-d64b-47a6-a3a4-c6b1d2a8e17f">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d65bfe21-f6b6-433a-9868-8eee64a57b2b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_19f678da-627c-4265-a695-4a07c9981220">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bed1f32e-09b6-4083-8f9a-87d8c997f7df">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7de6d9e4-466b-40ca-9eb2-57050058b0e2">EV <link linkend="DCM_121200" xrefstyle="select: nopage">(121200, DCM, "Illustration of ROI")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_081c16d4-8759-4063-bb24-f86082716b96">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_86df942c-5ae8-49ae-a72b-1d2f03d42485">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8ee2840-b2c0-4b64-8d2b-fd4331239381"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c9c4835-8892-4926-b8a8-16974eae8e20"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1708792b-18ef-4f5c-bf2f-1ba13e8ccd04">13b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_262219e3-299a-424c-8505-99c0e823a501">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_edf9965f-3c20-4849-90e3-c366a64bbc14">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eec8fe1e-7559-4584-a092-11271a3929e0">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_976a2eb3-f0ea-4338-b119-150f0f76fe7c">EV <link linkend="DCM_130401" xrefstyle="select: nopage">(130401, DCM, "Visual explanation")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c26e509b-f7b4-4211-9c2d-79f710f0950a">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e54c81ca-d4b1-47a9-b333-3dbe8754323d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67eef97c-8fc9-4853-95fc-a04ac08c8493"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8deeafb-9d48-49a3-acec-e8e01eb16cb9"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0462e87a-e352-459f-ab5a-ff3501d8b88b">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cdeaaf0b-db98-48f4-9b7c-d83fad955b5e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_797e9f54-c490-432b-ad0f-679ba3f492a2">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d63ed3c6-8984-45ca-88b1-46eb58143122">COMPOSITE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d6998a1a-033e-4dbf-9a20-6d99c3a0b325">EV <link linkend="DCM_126100" xrefstyle="select: nopage">(126100, DCM, "Real World Value Map used for measurement")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_23fea3e2-af9a-481b-8f99-6134e4e48d94">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fdda66e5-24b9-4b4a-8f0d-e5509f6af89a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d132218-0611-4cec-b363-53219250c890"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_53e1e712-a093-4575-aa92-aa1e129040ec">SOP Class UID shall be Real World Value Mapping Storage ("1.2.840.10008.5.1.4.1.1.67")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c54c872d-f10c-4078-8c7c-27bb9c21222a">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_455b7c37-144b-4a4e-aa73-97b9a27fb368">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_847063e9-4610-4854-8f38-979aa2385acf">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7ad7351-3cd4-41d6-a7b7-172abbabe0d5">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35053229-c6bc-4181-97ec-3091075c745b">D<xref linkend="sect_TID_1419" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fdb8a177-b3ab-4af3-8b48-0035174dbb3e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a2032be7-d5b5-4b47-a512-d048d0c26016">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_213933d5-6479-40a8-8407-8ceeb9f5ebd9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1655d89b-3fe8-4f78-a2f9-3fb462b2686c">$Measurement = $Measurement</para>
                                <para xml:id="para_777c7c47-4e86-41c1-8a03-8a8221fecdd2">$Units = $Units</para>
                                <para xml:id="para_a3f50919-52c7-4fca-8820-dcefb4589342">$ModType = $ModType</para>
                                <para xml:id="para_bb2a0a4e-205a-4fd8-8cbd-02d3525b0e8f">$ModValue = $ModValue</para>
                                <para xml:id="para_b84b468f-5223-412f-9b13-44d89d2dd87c">$Method = $Method</para>
                                <para xml:id="para_5fdce458-92b1-444a-8243-27c1a2bb29e0">$Derivation = $Derivation</para>
                                <para xml:id="para_e63c41d1-1785-40fc-894e-272949b8cc75">$TargetSite = $TargetSite</para>
                                <para xml:id="para_27a1e597-f046-4518-b0db-fe5a97c100fc">$TargetSiteMod = $TargetSiteMod</para>
                                <para xml:id="para_1dc4ae24-51e2-4c67-bda0-661286551f28">$Equation = $Equation</para>
                                <para xml:id="para_489d52fb-d665-42d9-b8c0-0462d7ce984e">$RefAuthority = $RefAuthority</para>
                                <para xml:id="para_cf708e4b-d9a8-4946-8ea2-cacc9d5c13fd">$RangeAuthority = $RangeAuthority</para>
                                <para xml:id="para_e9f5b925-f798-49b5-ad90-582ba8162bc3">$DerivationParameter = $DerivationParameter</para>
                                <para xml:id="para_f6bcefcc-d5db-45eb-8707-f6983d38f79c">$DerivationParameterUnits = $DerivationParameterUnits</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cbecefcc-eed8-4a03-be3c-4a4cdf6e398d">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6538d3cd-1704-41e4-a47a-8cc196767503">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_28fcb122-6814-4b6f-a838-3f76306160ac">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c51ff375-58c0-4c27-b9bb-2f25ae9236b5">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b640c7dd-0666-4a6a-aee4-5b8a6c5ba533">$QualType</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_08e7ea18-47f6-4be9-b39e-11a58b88d2cf">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c061bd5e-0509-40df-a552-9022c6ac90eb">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4133ea51-9f6a-494f-93b3-3423344cfa18"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f3fad43-8fce-4abe-86fe-dd440d082366">$QualValue</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3c41d97-ad9c-4979-9a8d-25105740a76b">16b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a27139bd-4c4d-423a-bb49-e9e3dd6abf63">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1043ee51-6c53-4e47-bded-537d9707e92e">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_066dc733-c7f3-40a1-85c8-0a4182b5e1b0">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_176ce700-05b0-42e4-8692-977d15c5dd35">$QualModType</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dc08b8fe-e825-4cc4-9438-f844599cdcbd">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1f667695-024d-40a4-b8ca-5e623232e2f3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06c27a1d-e090-4fea-bdfb-b8f04ba0d84e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_476fd8b2-1b4c-47ed-abd5-b925dcaf3d6f">$QualModValue</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae8bd215-bd2d-4838-a031-929b2655fc4e">17</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dbda9905-7e27-4363-9192-6bab01f0a3fb">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_23da4701-16f5-4e5a-af92-5d8df3df06c8">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46052da1-3820-48e2-8183-0ebd7c859a04">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3293880f-39bc-408e-826e-44a2a12aa798">$QualType</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e8e22b17-6d9d-41dd-bf49-53b7c3c0fd46">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_00318e42-3861-47a0-8976-441d6a9aa5fe">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_053773cd-3f06-4000-8cf5-2f06e33aea49"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1246061-f699-4d59-96f8-cc2e14b095ea"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_b60fecd1-f50d-462d-ba6a-1c914b17ae75">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98364871-818d-44d3-a6f0-ef67074f001b">Row 1b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b73102a7-f750-481b-be22-11897e50d2bf">Identifies the session during which the measurements were made. The NCI Thesaurus definition is "time, period, or term devoted to some activity".</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dafae3b5-f47f-41cd-a930-6538f8379303">Rows 2, 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa55f4b1-10ac-48b8-82b3-633aaa9b08fc">The Tracking Identifier and Tracking Unique Identifier are defined as a text label or unique identifier (respectively) used for tracking a finding or feature, potentially across multiple reporting objects, over time. As such, they are distinct from the Observation UID (0040,A171), which is unique identifier of the specific Content Item and its subsidiary Content Items that constitute an individual observation, and would be different for different observations on different occasions of the same finding or feature. The values of these Content Items shall match the corresponding values of Tracking ID (0062,0020) and Tracking UID (0062,0021), if present, in the corresponding Segment of any Segmentation instance referenced in Row 7.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb0af1a7-e4ba-410b-b63c-a73919ca01e8">Rows 3a, 3b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ff69ac9-4f87-41e5-bc56-02182bb54e8e">The type and category of the finding describe whatever entity (finding or feature) is identified by Rows 2 and 3. E.g., a finding might be a lesion, a tumor, or a reference region (as distinct from its anatomical location, which is encoded in a different Content Item (Finding Site). When spatial localization is by reference to a Segmentation, the category and type may correspond to the values of Segmented Property Category Code Sequence (0062,0003) and Segmented Property Type Code Sequence (0062,000F), respectively. See also <xref linkend="sect_CID_7150" xrefstyle="select: labelnumber quotedtitle nopage"/>.</para>
                            </td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1">
                                <para xml:id="para_fa1588d5-c0b0-4ae6-8a21-dd4e203ad93b">Row 5</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_5b259016-1702-407a-b89e-f8937befa83e">Even though the coordinates are image-relative, not every image slice within the spatial extent of the ROI is required to be encoded. That is, the ROI may be more coarsely sampled than the image slices, and may be irregularly sampled, and the omission of a contour on a slice does not mean that it is omitted from the ROI. For example, a user may not draw an outline on every slice. However, failure to include every intermediate slice does give rise to this potential ambiguity, and is discouraged.</para>
                            </td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1">
                                <para xml:id="para_f9cebd62-e9f0-4ff3-844b-fcb0826d8069">Rows 5, 7, 10</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_58c82a11-bad6-47b5-a8cf-018f5023eb6d">A single invocation of TID 1411 defines the entire spatial extent defined of a single ROI.</para>
                                <para xml:id="para_fe588548-a499-4389-a6e1-c15d26f5f9da">A single structure with multiple fragments disconnected in spatial extent needs to be described as separate ROIs, in separate invocations of TID 1411, with different Tracking Identifiers and Tracking Unique Identifiers, but the same Finding.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e52f281-af25-486f-b461-b626e2f2e688">Rows 5, 10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72f73806-17d2-492c-a070-95eb9bf8f3a6">To describe an infinitely small volume, such as the center of a lesion, a Graphic Type of POINT may be used.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92351260-8d35-4cea-9632-b60f0e29040c">Row 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e9a1590-6460-4684-9a37-b21abafc2d0b">
                                    <link xl:href="http://snomed.info/id/260753009" xl:show="new">(260753009, SCT, "Source")</link> may be used as a generic Concept Name when there is a desire to avoid having an anonymous (unnamed) Content Item.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ad17dc6-1664-4b8b-a7d8-0a6bd547d0de">Rows 6, 7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a344ee4b-2603-4c07-9969-c29e565fd785">Referenced Segment Number (0062,000B) is an Attribute of the IMAGE Content Item, and shall be present with a single value.</para>
                                <para xml:id="para_aea22b97-c31f-4d41-a51f-8b8dd95b6f87">If the Referenced SOP Instance is a Segmentation Image, it shall have a defined Frame of Reference. If it has Segmentation Type (0062,0001) value BINARY, it identifies the volume of defined (measured) region of interest by voxel values in the referenced segment with value 1. If it has Segmentation Type value FRACTIONAL, the volume is defined by an implementation dependent method. The extent, sampling rate and orientation of the Segmentation are not required to match that of corresponding image slices (if any), identified in Row 11 or referenced from the Segmentation.</para>
                                <para xml:id="para_2a348bb0-f614-4335-a72b-034d14684ac4">If the referenced SOP Instance is a Surface Segmentation, the referenced segment shall constitute a finite volume. It identifies the volume of the defined (measured) region of interest by the interior of the finite volume.</para>
                                <para xml:id="para_fdab5d3a-2a14-43fb-a1cd-f731294def29">Segment number shall be specified even if the Segmentation SOP Instance has only a single segment.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da291e85-6abb-4feb-a4b1-b18a89fbc13a">Row 10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10016efa-1951-4738-9cc9-8c960cc9f485">Either a single item describing a closed volumetric surface, or multiple items describing a set of parallel closed coplanar areas (contours) is specified.</para>
                                <para xml:id="para_97279843-776d-44f1-ad18-8abd2d9f211b">The sampling rate and orientation of the contours is not required to match that of any image slices (if any), nor are the in-plane or cross-plane sampling rates required to be regular.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f909f70-cd30-4868-bc4d-897aa81c362b">Row 11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e946b4aa-e3f2-4d0a-873c-522eb2642c32">Identifies the source images that were segmented to identify the ROI, when, for example a subset of images in a series was used.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd85fc21-38d8-4440-a684-b1f3da9fa6e7">Row 12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a4cbdb4-42a8-4791-baef-fd84ab032a45">Identifies the source series of images that were segmented to identify the ROI, when, for example an entire set of images in a series was used.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_40a37670-493e-4e1d-9174-dda56990eafe">Rows 12b, 12c</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7c1dc43-22ce-4ffc-b488-18e9307186ef">A reference to a single ROI that defines a volumetric ROI, within an RT Structure Set.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d05f88ff-b8b3-47d2-8237-915cb710bac2">Row 13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2545a9fe-b061-42c5-b8cf-564ea638c248">These referenced images may contain "screen shot" illustrating rendered versions of the ROI.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5e57ea9-aa55-431a-b2f6-619e26ed1adc">Row 13b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca27fe80-60af-4e34-9bd2-5ebc2b9b7907">This referenced image may contain a visual explanation of how an algorithm produces its results, and may be a "screen shot" of the explanation already superimposed on the source image (e.g., a "heat map"), or a parametric map intended to be superimposed on the source image by the receiving application. The type of image and the type of visual explanation is described in the referenced image's own metadata. More than one referenced image may be present, if there is more than one type of visual explanation, or it needs to span more than one single-frame image.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ec4b5bc-158f-4fd9-b6b6-279eb19ad24d">Row 14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eda840bd-9bab-4ed0-8c9e-22baf2e12ae8">The reference to an RWV in Row 14 allows measurements to be made in units that differ from the stored pixel values in the images referenced elsewhere in the Template. E.g., for a PET SUVbw measurement, the mapping from activity/concentration units in the referenced image that was used (and which may be reused for measurements in the future) may be encoded in a referenced RWV instance. This reference applies to any measurements in included Templates, unless overridden).</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_233f1497-641b-4286-bf23-bbde19ca0372">Row 15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21a76047-8aea-46fa-af56-9dac2b48529e">Measurements may be omitted, for example if it is desired to describe only the location of a finding or to provide categorical information about it.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37a12db3-1d0f-4ca7-baf5-5e784b57c8d3">Rows 16, 16b, 17</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ff8d621-a108-4322-a05f-935023846adf">Allows encoding a flat list of name-value pairs that are coded questions with coded or text answers, for example, to record categorical observations related to the subject of the measurement group. A single level of coded modifiers may be present.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1419" status="3" xml:id="sect_TID_1419">
                <title>ROI Measurements</title>
                <para xml:id="para_45f14227-f80a-4f1f-9af8-d035a27897e1">This Template encodes measurements for some metric, e.g., density, flow, or concentration.</para>
                <table frame="box" label="TID 1419" rules="all" xml:id="table_TID_1419_Parameters">
                    <caption>Parameters</caption>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_292e329e-f8e1-4947-8826-161d191fc0a2">$Measurement</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1086196-6daf-4d40-929c-e7e9df6fc186">Coded term or Context Group for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e51f23c-3bab-4711-b50a-6034423cfdb8">$Units</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0cfc2c35-e830-4881-a438-21c1b8707ce1">Units for the measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99c17fad-62f9-4561-884e-0086ca33500c">$ModType</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8be7b402-4bf4-4d2e-a22b-7ffb61748bb5">Modifier Name for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81b0a409-6835-485d-afb4-d7d80f19616f">$ModValue</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a421c619-8c68-49ab-8b47-71afc81a72ae">Modifier Value for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d6cdd202-bcba-4a46-963b-a2c274967bfc">$Method</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97c24ca3-30d1-4c54-8472-cb9ec48aba5b">Value for Measurement Method</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd549387-7bfb-4555-851d-dae938d0945d">$Derivation</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2fbe939e-284a-458d-8599-037b56ddb53d">Value for Measurement Derivation</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e5089ea-4435-4f68-ba60-3ae02c5599bc">$TargetSite</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f78d7296-555c-439e-93ee-d1185262bf92">Value(s) for Anatomic Location of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50cda1d2-9060-4344-b3c7-e48177de7bd2">$TargetSiteMod</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ebbb922b-40fc-4c82-872d-ef1bef3bc79a">Modifier Value for Anatomic Location of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1ccdf05-29b4-4ddd-a271-8344bbd908ea">$Equation</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ee80037-6d7e-4ab2-aa8b-4a5a3b180d78">Coded term or Context Group for the equation or table from which the measurement was derived or computed</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b729cc2-444c-4c52-b1cf-3cfb1e11025f">$RefAuthority</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a389270e-2a12-4154-be56-41a520fb8ea5">Bibliographic reference or authority for statistical properties of a reference population</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd1312d4-18f4-4622-a662-5f4e8935ca07">$RangeAuthority</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d71bbd51-faee-4dad-aaa0-710884671a33">Bibliographic reference or authority for the normal range of the measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2d133fb0-d88e-45b2-bf47-998020241f44">$DerivationParameter</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_49750e56-0ad3-4012-8fc3-2432de731396">Coded term or Context Group for Concept Name of a derivation parameter</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e0ccbe3d-5f65-4202-9cbd-157b3ac87770">$DerivationParameterUnits</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d75ae00-8189-441f-bf65-a916c32e2f1b">Units of derivation parameter</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_44828fcb-c085-4493-9fcb-fa75040f6acb">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_b679eae3-53f0-46ea-a58c-2f88a99d2741">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_1cfbed6a-4e51-4ec6-8b85-4dfff632cb9a">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1419" rules="all" xml:id="table_TID_1419">
                    <caption>ROI Measurements</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_12836944-553d-4d38-87cf-18a10f4027ec"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_46517370-7769-4cdf-86c6-7aa492dce62e">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_14515a82-f650-424e-9e85-f2ad8e617f3d">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_584e0384-4e44-48b5-b820-cae6f89883d1">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8724753e-a9bf-4505-bfac-cbe35b18ebd7">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_24ee3e66-d99f-43cc-b1ec-cab5e2af1d1d">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5514d345-0451-4361-bcbd-1ab9d403eca6">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_35905e7d-015f-4650-abc7-c4f3882b808a">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_613db39e-b4fd-4834-9441-3726f59ac635">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae7b9269-2ca6-4552-99b4-f2f15c58e179">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a3e9de5-1c2f-4741-b492-d06585fb1730"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9eaf09fa-7ce0-4a4a-91fa-bcce52a71005">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3f687a3-341f-4e27-bdae-8e1ac620a4ad">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb22d47c-a08d-40b6-b3a3-05e66fc56fdc">EV <link xl:href="http://snomed.info/id/370129005" xl:show="new">(370129005, SCT, "Measurement Method")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7120133-6db4-4377-8edf-a4d5b927e51a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c3f244dd-073e-4e7b-b05d-1215e3d1f55b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2887134c-e284-416f-8d36-4f558fbededf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b83b65c-fa42-46a3-bab9-2efb92d1dc03">$Method</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4bc5fd33-d0ae-4efc-aa0b-b5fec64992b6">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c668a93-713f-4294-a910-7da8ed643d00"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_daa1f94d-d1ae-43d3-b784-92f7ad907f3e">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a63e8e9-aa0c-4fc9-9d92-b8dd7ea0291c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_584ba5ab-3d7b-41a2-a697-bf568fe76bae">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_da6d9f63-86d4-4acf-ab99-73ce14bf2f98">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_08c19a43-a378-44a6-8bcc-9f18dab1f892">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31e78aa1-e7fc-4dae-9fcd-411264cbedb8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52c2fddf-e989-48b8-a4e7-f2ce3925b77d">$TargetSite</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_093528c8-e998-4869-a9a0-53a289bab84a">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4d07301-451c-4f2f-8b84-156dcd7fd81f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d6786ee5-64af-4420-9100-0438a6ce02d8">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29271ac0-dbb2-4855-a0ec-5aeb06c3ca22">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0335b521-2205-47a1-8907-af8d5dba043e">EV <link xl:href="http://snomed.info/id/272741003" xl:show="new">(272741003, SCT, "Laterality")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_629dc65a-d040-4937-9fdb-4d8e9ad38f71">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4380d7a9-114f-4aa2-9bbf-0c28197dabba">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7b0f6b6-53f6-41ba-b8fd-24a95745b19f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6cea5814-0e39-4d1e-ae56-2399fe33d84f">D<xref linkend="sect_CID_244" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_629818bd-201d-42a1-9a89-22ff48e20fc5">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc2293c7-f166-457a-a91c-52278831d46e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e06204a-3161-4e28-9a28-50c76d37c539">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_910a542a-d9e1-4d63-9307-85a93581ea9a">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe89f56e-016a-4523-a21e-a0211ae31af6">DT <link xl:href="http://snomed.info/id/106233006" xl:show="new">(106233006, SCT, "Topographical modifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f43b8a67-b5ce-484c-8e25-38ce72164744">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5b6322dc-62b7-4384-a285-d40f84747c24">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96b31cb4-5502-4bf9-aca1-8c3069ee686c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a6647a0-0daa-4be6-befd-a8bef42728d0">$TargetSiteMod</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_53440796-9791-4ccd-9162-06d446f2ed45">4b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c36d0d2b-d5fe-454e-8d9e-504200a9ca79"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ad22b6c-7236-480c-a645-869f81dde26a">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a824af8-8222-42ee-aead-659f86375cf6">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c3cd9a6-b892-4270-88a4-ff1984ab3957">D<xref linkend="sect_TID_4019" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7f7d829-8ed6-46ab-9cda-53b9f8e0567c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_53b11267-4391-4570-b52d-d37895cd9c4a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8860111c-64c1-49cf-a0d6-0b2f5c1d26bd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_065f6ec9-cdcd-42f1-a86b-9a45941d3174"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42dae226-407f-46d6-990e-4a3856d5dc2c">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3575aa5e-eba5-4a0a-9e81-7c84db2cfdb5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3fd739c-416d-481b-8a3f-894f2e240d0a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f540b40-5ed3-4a2b-aeba-aacba2b72a7a">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_451f249b-f32e-452c-b341-b9c68d09a547">$Measurement</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ca4a420-efd5-48a5-9a61-2b9bfc954a82">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1f6fc21b-ac48-4e10-a7ea-d44dd68f0ea8">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e7af36f-02f0-4ae7-9a77-7102cc7d851b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d7afdc57-827c-4ac5-9c2b-5ce3c6ddebd7">UNITS = $Units</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b85e119-679b-4716-b873-b3938706de2e">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0360226-e798-4c57-98e3-c0227a1904bf">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d4ea7f5-02e2-4e4a-8d95-172c68048ec3">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f09bd16e-6c86-4719-bcce-af1bcd7efacd">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69f80ec7-f182-4ee1-b80f-48d4616ebb42">$ModType</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7ab28def-a137-4fbc-a8e7-7954a74dba88">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d2c2e35d-0ed3-42d1-9eb4-26394898748c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bdaa55be-7339-4e00-96bf-f2dcb26497d7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_565d3344-f84d-43fa-a753-12479c89cf3b">$ModValue</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b3fb12f-7614-4cc6-a599-27aaa3d72372">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d46d3481-580d-4164-a6a7-92d80bbac92e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0bd889d-96de-418a-af3c-946da2b2a26e">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92d08bfb-e614-42ae-bc6f-66ae10bb4e79">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c2df53d8-5cbf-41cc-a7c2-dca790823367">EV <link xl:href="http://snomed.info/id/370129005" xl:show="new">(370129005, SCT, "Measurement Method")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0f8d3f1c-894a-4a6c-9c7f-e4fdc373c9b8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6006b8c8-0e2f-4ba8-a01c-a5874c2dca91">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_537de7a7-09df-433f-87c6-687c2da54c21"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7050a109-584c-4b43-82c0-0df1041d7940">$Method</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_545cfcfa-e38e-4fd1-bead-ddbb884fee6e">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_307af66d-3860-4503-ae18-7755280b0543">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_45021fbb-4fc1-44ea-97ce-534c10e2062a">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da90e240-f344-45a8-b00c-9266b11070fb">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b000c69b-a577-4621-9840-e21bce9b1293">EV <link linkend="DCM_121401" xrefstyle="select: nopage">(121401, DCM, "Derivation")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c8498272-5d5e-4b31-9a04-f9339d12f9e2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_04b39d7f-d9e9-4a3e-9589-226c305d8d1b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4607664e-7b7f-4b0d-9368-ce9da880fe47"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3063fb8b-3a89-4e85-a5cb-df37724dbf7b">$Derivation</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a846a6d-404f-4301-b21a-4fffee56f234">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9828437-9fb9-444c-999b-7ddd009e9f10">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a17c134-3059-4e85-b114-215c88bd59d3">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_863a473f-6f21-4572-a14e-b4478b964f54">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_14233ab1-3db1-4fc1-b7e3-fd2f72413f72">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e1641d8c-a893-4518-a565-f354fdcb917c">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_be39d380-ad2b-48c3-849d-e7c1648d67d9">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb834fbc-19a0-47bc-be56-ea5717a1d508"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36bb35e2-a584-4a5d-9a72-3c1341bb130f">$TargetSite</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dec009ac-d9b9-4e31-aa7d-9e5627f3f56d">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e17744e9-8428-464f-ad65-7c6c9d55de59">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93afb2b4-fb3a-404e-ad7a-8904e6801e85">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ecab110-105d-4383-974f-adaa77aa8413">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef4cc1fc-9c82-4bc8-b9a3-a54075d9fb10">EV <link xl:href="http://snomed.info/id/272741003" xl:show="new">(272741003, SCT, "Laterality")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e2661d8d-b1f2-49d2-9b73-9a9a021bf1b3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1afac7f7-00f5-4f25-8cb3-241bc5bcccb6">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_175dd4ae-6b47-451a-a5ea-43bf488169fa"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13e42fdd-4626-436d-816c-332d10ff6c9b">D<xref linkend="sect_CID_244" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d9eedb2-6336-4f41-9e37-0dcf0ce741ad">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d538f458-a702-4b26-985a-7f0a2675714c">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_169ea879-9647-46dd-897d-18b331003369">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3de1329-1c9c-4668-a1c5-269bc82f028a">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ccd7ed8-579e-4a54-aac7-2832ec41fad7">DT <link xl:href="http://snomed.info/id/106233006" xl:show="new">(106233006, SCT, "Topographical modifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_71cc3114-d78a-4f1e-bcbc-2dcd1e7b869c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_14ba85ed-8299-4a14-b5ac-367ffb0c5598">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a53b99b3-acca-4cf0-98b0-301279b5d032"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_690a24e4-f854-4982-933b-c52f4cca4066">$TargetSiteMod</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f06ec4f-00e3-42b7-abfd-679f469a5165">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5100111a-223d-4421-acbd-87b4fd4d2e5d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_254ced2f-5b0d-40b7-9f5d-b8e5f494aeae">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a930a3d-e474-48f2-903a-4d4d5c2e9192">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff589ed3-47d1-4278-8441-16d271a9e501">D<xref linkend="sect_TID_310" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_17b8cd03-d838-4fe3-98b9-3bd0ce86655a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b7e16452-8d42-4bf1-b89d-0f7abebbe9ad">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06d79ff1-9e86-4521-851e-3bae7f8bb268"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ceb6ba4c-0f6a-4ede-916f-42b8feba59fa">$RefAuthority = $RefAuthority</para>
                                <para xml:id="para_25959efe-8596-45d4-95a7-37f3509fe934">$RangeAuthority = $RangeAuthority</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6c1f29d-81ac-4870-92b8-db01871b0246">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5256e5f-5c7c-4501-ac99-280f111f0aa0">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84992584-15be-4f27-9f0a-36230954ccb6">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aee1334c-0155-4e49-980c-82f6c3ce419a">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_327316fb-f2f3-4307-bc02-f8269a7f6b0c">$DerivationParameter</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_42d5ab15-beb6-474f-b6eb-0ee2dd9ef3bd">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cc47179a-5040-441d-9815-82cd18949c7c">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c15e51e4-5088-46db-bb21-ae5a51e11a56">XOR Row 14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ae4cd2b-3e98-498b-9aa3-ce5390659bdb">$DerivationParameterUnits</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae21b7e9-8a3a-452d-9531-330b7ad1eca3">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7bc8bb76-807a-4619-8267-3b9f402c24fc">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7518e153-03d6-4188-b282-6d85a67ca1d4">R-INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1bc3e48e-45c7-4769-a28d-68c7057b088e">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7ca8c32-77b6-4eb9-9868-91e2cf13847a">$DerivationParameter</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_29ff2da8-43cf-4d0a-abad-76a052474a1f">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7aeb9cbd-da61-4d6e-920b-a1c94aa7f214">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92986de2-b1c0-4e4e-8936-2adc3e8ed31b">XOR Row 13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cedbcb49-4d66-48d1-b6be-4429a96b9088">$DerivationParameterUnits</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c2368451-573b-4f88-a9d2-8f1fc77c90db">14b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de4bcc5c-158d-4500-a89b-1ee0d1739ef0">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2720a6d-d83f-40cb-a37d-6f04cde4b407">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_104e399b-928a-4dfc-b1d7-05ca86509d28">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35a38f68-1b2a-4fa4-a63b-6f3d5912d9a6">$DerivationParameter</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_236d4a7a-71a5-4c5f-9784-69591f74c3a8">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a2c68857-1fd9-4476-88f2-439a39573d0e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8fdfe3de-9322-4a37-bbb3-d341afc74ed8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84686705-8007-4a86-926e-4500ea9013c8"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_117abce3-38fc-4825-86cd-144b5818ce5a">14c</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cad56a4b-c8da-42ce-a6d0-bd7993c96bae">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1b09422-6646-469a-8df6-f095977af8b8">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83779727-322d-4838-b740-026076276c38">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd32e8dd-97f9-4036-aedb-18c3375b1440">$DerivationParameter</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf6435f3-70ff-4627-9857-a1aa50b65c0f">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_77e00d6e-fe46-4520-995f-4043d836a9c8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4bc3ade1-7f37-4645-b385-aa597c7e3436"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb385c61-5960-4957-9ca1-5ea4e72e1f03"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e3fb6b4-1211-460d-b721-1fd9b68c65c8">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62369d95-cffc-4dfa-b695-b82febf06b69">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_affd6401-c8bc-4cb5-8047-4a3622a89f82">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_49575bee-89a3-45ea-8af0-61f0f07d445e">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51fa7345-1b51-4e8e-abfa-aa37c0a0eb08">D<xref linkend="sect_TID_315" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c923e41d-d982-429f-8071-1a413d79ad6d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4b9cae73-9089-43d4-b6de-21a23951d0bc">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4cd4f4e4-94f8-45ec-a882-5f052bbd5f78">XOR Row 16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00ff00f9-a860-4d28-b058-9aefd8a3e7b1">$Equation = $Equation</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e658ed24-63c9-429e-bb2f-b5c00c4de5d7">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e59562f7-7b2f-4d0a-b3bc-ffbff5b265e7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a6ffa8a-0e0c-4fca-9693-1166d06e1ef2">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05abde89-bec3-4758-b156-bee7b486cf67">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc57352c-79a9-410e-8d77-50b48835c0dc">D<xref linkend="sect_CID_228" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d50fbcf5-cf02-4b5e-a373-0a63c6b62d4e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f573b2d-c89c-47ff-a894-7a22136462cc">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_60d6c427-5bd0-48f9-a316-7ac191d7de51">XOR Row 15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae492543-dfa3-49bd-a7d3-7086071b4608"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92227394-d937-44b2-81ac-17bbb08e171c">17</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51716c8a-f408-415a-8c6c-003cf5697b76">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74d2a03e-c143-45c9-b448-7a7fc10a3269"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e5d5f73-34cd-4231-b82a-9c173458e066">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29b516a5-be4b-4286-be90-cbf9cfba6a61">D<xref linkend="sect_TID_1000" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2082260b-ab19-41fd-88e5-177156bafe58">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ca8536e-12a5-41f8-91a2-25a0e39975a8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_adb6ca0d-5d6a-40dd-ab59-7114bd3b2f17"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a4ebb56-b7d7-4cc4-a31b-d522bc272b57"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_789e110b-3b52-416c-a681-c59c1ad0d8b6">18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69e9cc28-e33f-46fe-b8d0-f59537a542a2">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a11f9efa-f14d-4b0e-8f7b-f10f288f833c">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74684059-7f7d-4264-a16d-474ece4c27b6">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6fd50ea-2164-4d61-b701-3d520dc22744">EV <link linkend="DCM_121050" xrefstyle="select: nopage">(121050, DCM, "Equivalent Meaning of Concept Name")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bd895bb0-f6ca-4987-881f-e5d116864ede">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c0c12e18-65c8-4b16-9e95-513f10bf3220">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6440a08-404b-43f0-b696-f5db055cfe47"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d56a9acb-98a3-427c-9007-ddeff4aafa25"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43243a72-7ca5-493b-b1b8-525778c80f6f">19</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d8646e7-8306-4bcb-9158-de936280ae74">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0432c3b3-b45d-407f-ba65-15fa59279ef9">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c328fdb4-f088-45cb-92bb-bc01b0d4f1a8">COMPOSITE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bbdbadf8-c315-44bf-af87-de8c15f5704a">EV <link linkend="DCM_126100" xrefstyle="select: nopage">(126100, DCM, "Real World Value Map used for measurement")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f9bcade6-9464-441d-871b-4605105a854f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aa8b8be2-7188-4c97-8058-99812a4d73e3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26a3be85-1b9b-49f1-9888-6c748050311a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52e1332e-e1d8-4174-b46a-76e649047ebe">SOP Class UID shall be Real World Value Mapping Storage ("1.2.840.10008.5.1.4.1.1.67")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82baac86-e021-4e9e-9542-90304973e540">20</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf316200-3a4c-405f-b306-c5d6603e85a1">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4377e26c-668a-48b9-a1c3-7ebe00493490">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e47c0719-70ed-4312-9f12-f9e418b68adb">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4497e7ad-0a27-4be9-825c-69839301088e">D<xref linkend="sect_TID_4019" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7837aad3-2875-4b1b-a7fa-4633c0cdd607">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_32479f30-e53a-4a8b-bad2-bee2ca6799bf">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce84bf37-0333-4f64-8f0a-cb6f250405f5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae471fb7-a381-4676-8800-5f665e47196c"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_6e05db3a-3563-4055-8835-7b0dec5c3f91">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr>
                            <td align="left" colspan="1">
                                <para xml:id="para_9a72c975-86b5-4074-9550-01f762a5176d">Rows 2, 9</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_c2e82fdb-2b7c-44bb-a767-9cf24830ec02">Finding site may be multiple when a region of interest spans multiple anatomical locations and there is not a single pre-coordinated code describing the combination of locations. E.g., when a maligant, inflammatory or traumatic process spans actual or defined anatomical boundaries. There is no requirement that the multiple locations be contiguous.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_412c398e-a1e1-4ed2-821c-ad52e5c59c47">Row 4b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0dc13709-48b6-43d7-8e29-a49014bbc90b">Describes the algorithm that applies to all measurements in Row 5, unless overridden within the individual measurement at Row 20.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_49b388fa-80c4-474c-aa27-5b2dc3d8cca2">Row 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2bbde9df-197d-4713-92e6-7058f557fa01">Specifies the metric for which measurements are reported, e.g., density, flow, or concentration. This metric is computed at each sample point (e.g., pixel or voxel) in an ROI (defined in the invoking Template), but those individual point measurements are not encoded. Instead, just the summary measurements for the ROI are encoded, and the means of computing a single value is defined in Row 8 Derivation (e.g., mean).</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4796593b-aab2-43b8-a595-733319ba48d3">Rows 1, 2, 3, 4, 6, 7, 8, 9, 10, 11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a9d5c86-be02-4dde-a885-7f9b55c2c8ba">The HAS CONCEPT MOD items allow the explicit definition of terms for post-coordination of the measurement concept name. Additional post-coordinated modifier terms may be included in a SOP Instance based on this Template, in accordance with section 6.2.4, or as defined by Templates that invoke this Template and explicitly define additional post-coordinated modifiers.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4dcff747-abe1-46b4-8546-23994df0bdf1">Rows 13, 14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_68a78026-d9fd-4722-b754-a02bdbbd8c36">The INFERRED FROM items allow the specification (by-value or by-reference) of numeric values that were used in the derivation of the numeric measurement of Row 1. The nature of the inference is not explicitly conveyed; it may be implicit in the Concept Names of the measurements. Inference by-reference is valid only in SOP Classes that permit the INFERRED FROM relationship by-reference.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9a4d48b-d036-4b6c-925e-9d8e89615cc4">Row 18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c70535a9-847e-49f6-a9bb-4d16bb29411c">Equivalent Meaning of Concept Name allows the creating application to specify the preferred composed concept name representing the measurement and the associated post-coordinated concept modifiers. The concept modifiers may include those specified in this Template, in a Template that invokes this Template, or at the option of the creating application in accordance with section 6.2.4. This composed concept name may be rendered by a display application.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02edb578-615f-4f7d-8ea6-ff265da30ea8">Row 19</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51e1a9da-d95e-46a6-a862-9780cf23241d">The reference to an RWV in Row 19 allows measurements to be made in units that differ from the stored pixel values in the images referenced in the parent Template. E.g., for a PET SUVbw measurement, the mapping from activity/concentration units in the referenced image that was used (and which may be reused for measurements in the future) may be encoded in a referenced RWV instance. This reference overrides any reference in an including Template (such as for a Measurement Group).</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1420" status="3" xml:id="sect_TID_1420">
                <title>Measurements Derived From Multiple ROI Measurements</title>
                <para xml:id="para_9df250f6-e02c-4765-8c7c-c09a36421a6f">This Template encodes measurements for some metric, e.g., density, flow, or concentration, which are acquired over some defined sampling (e.g., over successive time slots in a dynamic contrast enhanced acquisition), or of some comparison between different ROIs.</para>
                <table frame="box" label="TID 1420" rules="all" xml:id="table_TID_1420_Parameters">
                    <caption>Parameters</caption>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d39acfb-e782-4269-a731-3184b9ebe240">$Measurement</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e86f8da9-c108-4890-b251-feb42af4adeb">Coded term or Context Group for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cceb02b1-8864-4cce-91e6-563af6a49da4">$MeasurementUnits</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a86bcf2a-f0bc-43cd-bf46-38dd20c0ce1a">Units for the measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef5315b0-8681-453b-853c-dfb7d777a93a">$ModType</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ebf5f613-b0a6-4cf2-9ec5-cf2945edef61">Modifier Name for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e113b6e0-3dc7-4eb6-b64b-9c380484b371">$ModValue</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8368b153-5a83-4516-b310-afedb3a72a49">Modifier Value for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd6a500f-ed69-4215-84f8-fe8d947acb6b">$Method</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8471ea4f-eb7b-4ad6-8070-d3d6fd900369">Value for Measurement Method</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc5ad144-b7b3-4410-9bce-ea33f6d7ad66">$Derivation</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ef9f09a-02b7-4b40-96ea-d3515ccb8576">Value for Measurement Derivation</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7453e2dd-e8fe-4b22-9471-9adb2d9ff87f">$TargetSite</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_589d1e08-25c9-4dfe-b587-881d0571e532">Value for Anatomic Location of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f975424-c0cb-4d48-bd9c-2d17e4376486">$TargetSiteMod</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_71c66648-d8ff-49bc-a4b6-08bf4c8198ef">Modifier Value for Anatomic Location of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_705ff62d-50fd-4bec-a9ec-5fc9588f9608">$Equation</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5cfbc36-4509-4fc1-a4fb-474cdc494350">Coded term or Context Group for the equation or table from which the measurement was derived or computed</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f69bc63c-8119-49a1-b770-a4b565987e48">$RefAuthority</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38130d58-88d3-4a31-b24a-28f4dd6c43b2">Bibliographic reference or authority for statistical properties of a reference population</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1a85dfb-fd23-451e-9ab7-252826d042be">$RangeAuthority</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ebe6252-e9f8-4968-923e-d18c114a593a">Bibliographic reference or authority for the normal range of the measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c1c44c0-8d7c-4796-a14b-b7a1623c39ed">$StatisticalRefAuthority</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48749cf9-819b-4010-88e1-c824b273efdc">Bibliographic reference or authority for statistical properties of a reference population</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4fe829dc-3044-4d94-a4ef-6fa96208fdae">$StatisticalRangeAuthority</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_53948ee2-f3a4-47ee-ad9e-89b02d24364d">Bibliographic reference or authority for the normal range of the measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb5db378-8041-45a8-965c-9fe7894961a2">$DerivationParameter</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c98a21fa-20cc-4e8e-aba3-b25e9b398bd4">Coded term or Context Group for Concept Name of a derivation parameter</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06c476cc-c751-47ac-ab83-4240e40f5df1">$DerivationParameterUnits</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_44dd9abb-45a7-4767-b2b9-0f72d01c8389">Units of derivation parameter</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_e1edf68e-0494-4809-b441-4296e0aa6690">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_e8dcee4e-ab41-426e-a2b0-53cd038920f3">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_25bce007-e221-4149-8d47-a828cde8e665">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1420" rules="all" xml:id="table_TID_1420">
                    <caption>Measurements Derived From Multiple ROI Measurements</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9e411d11-543b-4a68-a43e-f5aee7f147cc"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a7e5a8c8-6ddb-44a0-b404-6c4cc0e110b0">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f9cc89e6-e72f-4f6b-9701-a4165fbfc528">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5ccced9a-84f4-40d4-b0aa-4d02b57864ff">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c0649b26-7bfd-4862-86b7-69fe6518eb5d">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f0e0aefd-ebea-4ce0-869b-2233498051c9">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_339298a8-6e97-4ca8-86c8-83766e448893">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1fe7962e-a065-4e2d-959d-c3134c125593">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_251c8a3c-517b-453f-b01c-cab4a7fa527f">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5533c73f-7886-4274-8930-42f6160092b7">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5479196b-844e-4b40-bb1e-bd23a4278211"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e69788e-f643-4955-8248-53f4656c21b2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_60ce69a0-334f-4ca7-bd9c-32dbb3ce11fc">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0d68e7d-1fb5-4e9e-b17a-69b9a21cede0">D<xref linkend="sect_CID_7465" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_05584e7b-106b-4d86-9d6d-64cdda4bd877">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a52ab315-7c59-4be9-8b69-6f7fcdc162bd">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bcf70806-f8a1-4067-bdc5-9f6adabc297e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_006cc400-6f06-448c-9ff7-2b8010bd2556"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_218e9c9e-86d8-43e9-9c0d-ae46df2fb716">1b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_995ee572-5241-4349-a159-36602b0cf57c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c7b76ca-422c-4170-a8f1-be26b2a9ef39">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70b681ad-6ca7-40f0-a634-94717d77a4a0">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ade24d3f-4f3b-451d-a568-bb5582a40105">D<xref linkend="sect_TID_4019" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d471817-4ad6-4e9c-a0cb-98bec2b5f912">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_be8c765c-0160-4e6d-adfc-5eb15f26d307">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be6cfd54-7eca-4762-a341-33c263a6685d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96dad921-d448-492a-b197-c0b6bf98ca0b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0842058b-1f38-49d2-9d70-41a27e946f44">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_232a17a7-0233-467a-b793-9011f7a68d0d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d9b847b-1c67-4055-b4fd-8ed3fd4239b4">R-INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4304021-1c04-4e26-9f91-af9a6636b940">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d30f6fa9-b814-44b7-801e-6180cc9af335">D<xref linkend="sect_TID_1410" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_752dc534-660b-472e-b2e6-d5543e4b4281">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a9a8134f-162f-492a-b9b5-036e9fe6a8e0">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_20665cc5-9a8c-4300-8aba-55a9fd65dbda">XOR Row 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed8b0bb4-7c39-4a36-9595-69136b75e1ea">$Measurement = $Measurement</para>
                                <para xml:id="para_d76ee771-5a44-486d-8564-71be9f1265e7">$Units = $MeasurementUnits</para>
                                <para xml:id="para_0162155f-dc50-4c58-bea0-1117c84ca30c">$ModType = $ModType</para>
                                <para xml:id="para_fd21bca7-721c-4503-bd16-d43d0b64a7f2">$ModValue = $ModValue</para>
                                <para xml:id="para_27021f8e-c6d6-4a1e-a48f-debafa1c2204">$Method = $Method</para>
                                <para xml:id="para_46a78d7d-0564-40b4-9bd6-22579dd273d5">$Derivation = $Derivation</para>
                                <para xml:id="para_68f2bf4e-ffce-4aa6-94c5-a523ecc80dc3">$TargetSite = $TargetSite</para>
                                <para xml:id="para_dc5b63a0-9eca-44cb-9b6a-4d08338b19ee">$TargetSiteMod = $TargetSiteMod</para>
                                <para xml:id="para_4f854b24-b35f-4505-a3af-fdb6ef625ccd">$Equation = $Equation</para>
                                <para xml:id="para_df34ec0d-9572-421e-bb1d-e79c3f35a896">$RefAuthority = $RefAuthority</para>
                                <para xml:id="para_fa2756e4-a4ae-498c-a694-7159ab4d7ca9">$RangeAuthority = $RangeAuthority</para>
                                <para xml:id="para_a816eaef-b146-49f0-946c-fe4ae0cdb8ba">$DerivationParameter = $DerivationParameter</para>
                                <para xml:id="para_fe24eda5-8e8a-4015-bbe7-ff7f508b20e8">$DerivationParameterUnits = $DerivationParameterUnits</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4b43efe-c43e-4aa1-8d26-e8eb21ab0192">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1bf454b8-5fd0-4592-a0d8-5d124967c897">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b11a61f-7f7a-4708-9440-e0cfe1cf30bf">R-INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67305b7d-896a-4870-b829-3d029184825d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_177f5996-bb22-4ed4-a2ba-a5b539dc8a6d">D<xref linkend="sect_TID_1411" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_93771a4c-527c-47ba-be5e-3cde20f6db5b">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a4bbfb9-8502-46b0-985f-ec76d3f7a933">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51924fb0-2153-4458-ac8f-ce4390c6e17e">XOR Row 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b12e1b0-abfe-4d24-b6dc-62dc575d5edd">$Measurement = $Measurement</para>
                                <para xml:id="para_46d954ab-3484-40e5-bd03-e917b6d6282e">$Units = $MeasurementUnits</para>
                                <para xml:id="para_fec8a770-3019-40c4-8933-a993bbf65119">$ModType = $ModType</para>
                                <para xml:id="para_99400846-1bbf-446b-a148-99f0929e28dc">$ModValue = $ModValue</para>
                                <para xml:id="para_1999e178-18bb-43d3-9882-4dd319800090">$Method = $Method</para>
                                <para xml:id="para_6254fe20-bb2a-4a60-a0bb-66e10a58d004">$Derivation = $Derivation</para>
                                <para xml:id="para_adecf9ba-ebda-4910-9daf-df403bdeda58">$TargetSite = $TargetSite</para>
                                <para xml:id="para_a886323c-9b2b-4ec7-be81-82599165f174">$TargetSiteMod = $TargetSiteMod</para>
                                <para xml:id="para_a70d9baa-26c4-4aa7-a6bb-5dc569d29ada">$Equation = $Equation</para>
                                <para xml:id="para_b6100e4f-234c-4324-9d35-dbba6eb89691">$RefAuthority = $RefAuthority</para>
                                <para xml:id="para_8c2113ff-43e8-4457-b1f4-e13020c12965">$RangeAuthority = $RangeAuthority</para>
                                <para xml:id="para_1250b240-041a-4ccc-a2e9-069253efbad6">$DerivationParameter = $DerivationParameter</para>
                                <para xml:id="para_b67cf4a4-566d-4bcc-92d2-bc9e499d766f">$DerivationParameterUnits = $DerivationParameterUnits</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0dfc43fd-c883-4ad7-8f6c-9e943ef0046b">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e075582d-a65d-40b2-b359-16eab5fa2bf6">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70ebe3d3-c2f8-49ea-a19b-85ecf29e86e6">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b01c11ac-ff8e-476e-9361-25f82fd6e672">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c75f5d10-36e3-4b4b-acc1-e5452c147208">D<xref linkend="sect_TID_310" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c5a8443-34d7-41a8-8dc7-1d1f08ab2dd5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_00132e42-a53f-42fb-a8e5-e6fb25235738">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_886b417e-1899-4793-b792-ae322d5fb39a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eda3d1e5-fb1e-4d75-821b-3f54d3e045a7">$RefAuthority = $RefAuthority</para>
                                <para xml:id="para_c84d9693-ab05-4094-89fe-b68f4c7e5d1a">$RangeAuthority = $RangeAuthority</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_ab33149a-38bc-46fe-9836-4d6aa9136e7e">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26f45afc-2c7f-4e64-82dc-dd6eb4cb6497">Row 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97b50270-9192-4555-9303-852ce5d3d288">Specifies the type of derived measurement reported, e.g., the mean of the individual ROI mean density values, or a similarity measure of the number of pixels or voxels in the ROIs. Note that the units may be different from the units in the ROI measurements</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9154321b-fd04-40cc-bd46-f60d23d28b67">Row 1b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9b68056-9891-4823-9cd8-7476324ca573">Describes the algorithm used to produced the derived measurement, as opposed to the referenced measurements from which this measurement was derived.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8272c8ea-678e-4534-a73a-82b2a54ebe77">Rows 2, 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_945c7f06-a608-44e2-a953-1297b8f948f9">The measurement values of each ROI that contributes to the derived measurement, e.g., the mean density within an ROI, the number of pixels or voxels in an ROI. These are specified by reference, so as to not have to repeat the ROI information when it contributes to multiple derived measurements (e.g., if both mean and SD of ROI mean density values were specified).</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1500" status="3" xml:id="sect_TID_1500">
                <title>Measurement Report</title>
                <para xml:id="para_451fd560-e4eb-4e0d-bbbe-a2b2bc35cfdb">This Root Template encodes a list of Measurement Groups each containing lists of measurements, together with any derived measurements.</para>
                <para xml:id="para_05032633-832f-4009-aa1a-4cd0169bbcf6">Each Measurement Group is identified by Tracking ID and UIDs.</para>
                <para xml:id="para_ae0f46e9-777b-41b2-9bcb-f73d2d26cdc4">An image library is available to describe characteristics of the images referenced by the measurements, if any.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_dc288621-3a74-4a7d-96e1-b497f9db2c31">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_3d90285a-5fef-466c-a809-b84a2ea3bd77">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_554a2a02-c45c-4450-86e5-c176d0b47f9a">
                                <emphasis role="bold">Yes</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1500" rules="all" xml:id="table_TID_1500">
                    <caption>Measurement Report</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7f96ef72-3739-4709-a6f5-d3c609e4ec05"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eb663436-d709-454e-ac93-98682212c9f0">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6142a93b-0f6d-44a4-8494-fc3299ba7c21">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_81a6fa58-162c-4816-971a-d0a224744ee1">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_97622db7-889d-46d0-a1c0-605bfed0f4c7">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_feb517dd-7464-42f5-9f1d-496753de6be4">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_220e6ae8-5f33-4f58-b426-f41cd8fd2bf4">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9af3785d-8f23-4d07-809d-5639784468c9">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_80f6672b-b0af-4725-adc3-e4e8c7e83695">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3321887d-8899-4314-b289-3d0e04bcdf8f">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe0e84e0-be0d-437f-8baa-f2478513e5ee"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8ae3ff8-c9ea-42bf-96e0-2414f44efbcf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85dac8a4-19f9-4283-bd59-d51aa905412d">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e81e20b-a511-403a-893f-29ce62ab8e77">D<xref linkend="sect_CID_7021" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5b5a81ce-2cb2-47bf-9730-858f4fea4387">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0b360053-7fdd-4be5-91bf-eaea1c56d55d">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca0229a7-7804-4c95-b314-b59248fade6c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c53c5359-96e3-44c4-8875-94dba07faea0"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5ac092d-eeaa-45ba-879c-a39bba6c2100">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1705bda9-2729-433b-b8c7-c5b5f168fd7c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5e9aa3d-f666-40ba-afb9-be0318db6abb">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_41d18321-138a-49b9-99b0-d9c6299e1ebd">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3a1d138-27b3-448d-a98e-c3786582374d">D<xref linkend="sect_TID_1204" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b4aa3aa6-3fce-42c4-8886-f07a6f72822c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_28838a6e-bd40-47a2-93a5-8102b4f17ca3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11daccbc-892c-47c4-8886-974b5f559550"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9cb3169-601e-461d-9fa0-c53633bd9a32"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d0b694f-7502-4855-8593-331163f0295f">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb033089-9e52-48e2-aa2d-210196ea542e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_769bd3a1-4bec-4f66-8dc7-ea4ab693e9cd">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_894b2787-c1b2-409d-a4a1-5087ded35704">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0bd4622a-9209-44c6-b887-bb1bf832faa9">D<xref linkend="sect_TID_1001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e8f59bbe-d412-41ee-9f51-b64c959314dd">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_19d56cdb-e2e7-428a-bc46-0c106b449f0a">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52937701-d101-4a96-8690-0878f00ad37e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6f420ac-47ed-40c3-897e-83af35788099"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de6b0f6a-bca6-4d64-9c8c-02fee993db8d">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73aea91c-c269-4b53-b5b7-f83f9759f5ba">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca90082e-d67a-4689-9524-8db7e75a95f6">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21119694-7dc8-47bc-b79e-a3aaef33a4c5">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a37e0410-bb3c-4aa2-8dd4-f4e2d2857fc5">EV <link linkend="DCM_121058" xrefstyle="select: nopage">(121058, DCM, "Procedure reported")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_36edc419-b874-43a5-ac21-02225e5f68c0">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_72c5b1eb-2c13-45c7-8bae-707a90971c12">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5bf111ee-8cc1-47be-b116-cf1a9c9c301c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8377a8e-6a5d-4f93-b11d-07aa93711f36">B<xref linkend="sect_CID_100" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69135bd9-e619-4010-bfb0-9a26882096f3">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_089ee540-5798-4812-8fe2-920e783d10d6">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_20c193a9-b9d3-465e-a85a-6de1184ad979">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9ea4a21-6c60-4346-888d-9fc4442545e4">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cbf297e0-931b-4014-bc16-7be446cb7cc6">D<xref linkend="sect_TID_1600" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c1a95d6c-24ab-4b0a-ac89-72ca698fb5b6">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_44e96e95-2fb0-47e4-adf3-2411b755dc94">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13e3ac11-53fe-4caa-8543-ade0f92b9840"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dbc3a6cc-0958-4084-96b2-9e0f8cda7d1a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8db842c-0b5d-4809-b5f7-5414422e2aca">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_acd4ceff-ae4f-4e83-bc99-27092e318603">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf056d16-e8ba-482d-8ddc-d5113320cf49">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ff0b318-d282-4163-9f2e-fdac666bad46">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a55999e-9b7a-4082-a550-f4cea95ab6e0">EV <link linkend="DCM_126010" xrefstyle="select: nopage">(126010, DCM, "Imaging Measurements")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6b3b7a9e-eb99-4f87-a6e4-6cc3e8513983">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_34df0c4c-cfa8-4c66-a27d-de2b8d9e3f85">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37a3cb9d-3117-401d-b28a-44ba2e697fc7">IF Row 10 and Row 12 are absent</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_db8f2474-f267-4c5a-a382-e6c9459b921d"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c96b1e4-8f28-49b4-ab52-23163326adb9">6b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4be51a18-defa-4624-9371-6f190b0a98ef">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab0e8481-720e-4100-8df8-4c8e98d31995">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d75e20c5-31fa-4efb-86e6-dea658263224">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_663ba769-03eb-4668-a863-3e6d70361913">D<xref linkend="sect_TID_4019" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_601c7073-4f83-4e4f-9685-b8f0d614bbfd">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b74cb42d-4b0d-4e25-8159-30db42e9536b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd9ea8c8-9a65-4d6e-b662-dc7631d3cfac"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1938a3da-ac61-4367-b45e-4e50e11ea7d7"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96d6cfbb-9f8d-4203-92f0-dc6f05c2d0a8">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ef2d231-13a5-4959-a821-9506f815bff7">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f15deab-dd23-4d60-83de-dd6a73b90078">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ce9f59e-0b11-4f3a-aa05-a88e1aa9c1ae">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_77bd714c-3790-436e-8fde-280daf9850b5">D<xref linkend="sect_TID_1410" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a9103603-6261-4637-b46b-fa22134536fe">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_15f776e2-a5af-4ee4-8902-8d861d3932b7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d25704ea-5734-4683-8a36-210409afacf8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a87b6e4f-bced-4eb7-85ca-72f7b53d423c">$Measurement = B<xref linkend="sect_CID_218" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_378db2d7-b6b1-4bd5-bd55-3ecc1936deb9">$Units = B<xref linkend="sect_CID_7181" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_99508cbb-2bee-4f5b-8816-1d3495eccb3c">$Derivation = B<xref linkend="sect_CID_7464" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_d653b285-fe19-47d0-9b09-d0cec3ff9359">$Method = B<xref linkend="sect_CID_6147" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_8fd8bf04-d3fc-49f5-b3d4-55ff1178c494">$QualModType = B<xref linkend="sect_CID_210" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_d35368af-042a-4bc5-beaf-e97bd40eaa60">$QualModValue = B<xref linkend="sect_CID_211" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_237b4895-3ec5-42f6-83d7-ca4b9914ce10">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_34b0264b-6367-41ef-9ab3-ac6f73e5a926">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_edd197ad-42e1-4181-b741-9f29a3ca83f8">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38ae7415-a014-4b38-bba5-90c84f6d89c9">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8276a87d-183b-4ec0-9de3-c5b2ec064c57">D<xref linkend="sect_TID_1411" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e654f7db-b58f-4a0c-be26-9679fe2714ed">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d0a9eb71-ba77-4b3c-92b0-20807066566c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_637e45d6-6eee-4f3f-9ce5-fb5d384ae031"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2b0eb06-c798-4882-abec-a2632ac19b44">$Measurement = B<xref linkend="sect_CID_218" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_d952336b-31c3-4a64-a013-7ff63702a47c">$Units = B<xref linkend="sect_CID_7181" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_9f14bfcc-5741-4404-9156-21acc26e58d2">$Derivation = B<xref linkend="sect_CID_7464" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_7ad66743-b635-4689-8f59-e97ffa3bde7d">$Method = B<xref linkend="sect_CID_6147" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_03bf3182-8998-4219-bf57-ad41160dae5c">$QualModType = B<xref linkend="sect_CID_210" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_813cf435-a98c-4ca8-a542-7cc4a7f11cb9">$QualModValue = B<xref linkend="sect_CID_211" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e00ee47b-e07a-4063-9295-f00b8f902998">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75af0046-0485-49d9-8863-6ce205f822c6">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa985cec-610b-4445-b7f1-2ebbab06936b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51feb8fa-c5e0-46a7-afcb-b82dc0f31423">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_afa5de9d-884c-4de6-8af3-0f259624c15e">D<xref linkend="sect_TID_1501" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f0cc25ff-0ec1-44cd-a6c4-4ba948d2a1ae">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2c07259d-38bc-4ccd-94bd-f6802ad60bf1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87d9dd51-a193-4405-b81d-59c4610661d1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17c5d93d-3fbc-4a4b-9dc6-71a477409861">$Measurement = B<xref linkend="sect_CID_218" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_1bd79cf9-8707-403a-bace-11f90ec0738c">$ImagePurpose = B<xref linkend="sect_CID_7551" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_56c17377-8203-49db-abf1-3e609e9ce931">$Units = B<xref linkend="sect_CID_7181" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_33b0e4c5-3954-4eb8-89c2-efc8fe79d202">$Derivation = B<xref linkend="sect_CID_7464" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_2b135bc8-4839-49ce-9cf7-18949e1ba320">$Method = B<xref linkend="sect_CID_6147" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_35455f5c-df30-44e1-831c-09a7456f8614">$QualModType = B<xref linkend="sect_CID_210" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_4f5fbccd-7f99-468b-af89-55ae995e7628">$QualModValue = B<xref linkend="sect_CID_211" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f35f1012-6565-4615-94b4-a578329d628c">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ccf6dc7-6bfa-4c00-a480-e01762c81728">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bddc1cb2-753b-4cfb-afb9-4e7d0a9a5b88">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_20defab9-20a6-4f11-8d8d-5dc3d112bce6">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_41dd250a-8b5b-4dbf-8841-b031757426a3">EV <link linkend="DCM_126011" xrefstyle="select: nopage">(126011, DCM, "Derived Imaging Measurements")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_22a0c72b-ee47-4b01-8193-4fccee14c0f8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_86f3c834-9d4e-457b-9727-a65324c488fe">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30d76f5b-1438-404c-8012-2bfb78dc0bc3">IF Row 6 and Row 12 are absent</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87acdb58-5f9a-4c02-b01a-4e3975a65b68"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8fe61e3-72f2-4b02-a51c-44563b59b978">10b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a4a34a9-de6f-44df-95fd-435be79807e2">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ca08070-3f41-4ae9-a44a-f5aef6842373">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_892802bf-81ec-4bf3-a07c-b186deb68678">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ae0e1a3-84c0-48d7-bc70-696f1f329c73">D<xref linkend="sect_TID_4019" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_748bc817-c27c-40de-b5e3-487af83b9d15">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_37a35928-b507-4371-9ec3-26ab54918680">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3496ac24-599c-4c88-8589-a7357a4e0d1e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f83e70c-e942-4ffd-b5de-05054b8ef981"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td>
                                <para xml:id="para_4dbbe995-3b21-4ef6-acc8-f8e82a43c014">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e19fbf7f-6880-43dc-8a0e-e04dded8b987">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_94f538e7-d77b-45ac-8745-7926463117b8">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6edc5ae3-633e-4b7b-8ed2-8fda35a733bf">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e0869a6-aba4-443b-8a8a-0a9a242b084e">D<xref linkend="sect_TID_1420" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ebd888e-3d5f-481e-8cc2-d27a627f050c">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2285bebe-5845-45ac-ba0b-e496db27fc79">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d908f8c-a89b-42f5-82c8-76b4377d81df"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b8f4b122-190c-4172-ab6b-1e3ef7dbf2fd"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6303ba8-e73d-47e2-b3f3-a8ef763670e2">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46385195-5342-4453-bea9-10a9a5e847c4">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e920f388-7676-4925-95be-ea982490ed11">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25092981-319c-409c-9dd1-9ea2999ec332">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c6a4a43-d145-4388-bdef-847876a32127">EV <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0034375" xl:show="new">(C0034375, UMLS, "Qualitative Evaluations")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ab8cbaaf-8524-43e5-b0ce-aa67fde75001">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bebf19ad-7f8e-4877-a86c-b22e858a021f">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a7df7bb-aa04-4abf-b4b1-d3a796e31a9d">IF Row 6 and Row 10 are absent</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce6d2583-fcb3-407b-8163-f8af1ee4f1ae"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09725f43-f128-4537-8866-3a9392f2f3b2">12b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f310479-e3e5-4768-9ff9-ba05e92dfa2a">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b945050-2ff7-45a9-b287-d6e2df84fc2b">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_987f6ce5-846a-41e8-b2a7-e0964d012ab0">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_56a2f620-ce1b-41a2-b6c1-ade441a3e768">D<xref linkend="sect_TID_4019" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0c7abeae-4753-4c02-a30f-f33b909ce8ec">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e4de26e5-c533-4f81-bc09-17ac65a87f6e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_150cce32-5428-4eb5-96ae-acbe5bc7e4c1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ce4b328-f036-4116-9a46-8a7ec0b074b6"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ae96bcf-1778-4a2f-8f33-2f300c0db2b0">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d80579d-2158-4e3f-9c06-060995308632">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65242578-3b90-4010-b8b5-e1105e04fef6">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0ae5825-e6b1-4dbb-8154-6e53132b2fe5">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97685e5a-e9cd-47b1-a9ee-c3573027dbb1"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7072bd7f-1dbb-44a9-a126-90f9eb514a70">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_25ba4a6a-6743-441c-bb3f-fe9a38515976">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4cc22382-35ea-4094-b218-49471bb2254a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38da5bd9-00b5-44fb-b597-168e198ee097"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0c5919f8-8a84-46be-89ba-ec3bedb57458">13b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8770762e-94a4-492a-bdef-1c9a9ada9a6d">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f5296e8-7e13-4c8c-80ba-dd0f796f0dee">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa3e1ced-f228-43b9-8a69-faf60be1d228">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab9a4d87-c570-4a15-9173-0415a86a1c07">B<xref linkend="sect_CID_210" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9f920272-f652-47ad-a35f-6f684aa81986">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_18736d14-17a7-49c5-98aa-abd61b27d7f9">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a665cad2-b45e-4f83-8bba-98f35732dae1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_adcf14d1-aa3a-4452-98db-26f5c99e4aec">B<xref linkend="sect_CID_211" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8f1ea39-3c67-465b-a6c0-e5ec9e55e62b">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a53b3bf9-cfde-4fbf-b60a-268f596778ec">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba2a86fd-3a78-4582-a15a-dc5e41d48a6a">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ccaf0d9-7de6-4a29-abe8-fad1e57f1783">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_365d761d-516b-4a79-a9f1-19553ce85870"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e2921fd2-68c6-4638-bf28-994fd99a0d2b">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c2054dbc-f637-457f-8b1c-ab6c08b8c103">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec6954c3-d4e2-422d-92bd-d2a4be05f8f6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5a385a8-29ef-49cb-9bf6-181e68405efc"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_868f2065-cd1a-426f-a9fe-19f831d32718">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b16ced6f-61d5-4c31-878a-221f3cc50682">Row 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_384077e5-2f6b-4ff3-a435-f8a6dbd1534a">The Image Library provides potentially relevant characteristics of images associated with the measurements. There is no requirement to include all, or any, of the images referenced in the ROIs and measurements elsewhere in this template. The template may also include images that are associated with, but not directly referenced in, the ROIs and measurements.</para>
                                <para xml:id="para_f0efbd35-959d-4a31-8e93-4292f4652798">The Image Library is not replicating the content of the SOP Instance Reference Macro.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c81883d4-3a76-4f4a-8408-9ed9e49c2b75">Rows 6, 10, 12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d3926d3-2967-4b80-9371-98b72ca99b65">The conditions require that at least one of the "heading" containers be present, though any of them may be present but empty.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4bce59a0-85e8-4b0d-a8d1-c7773909988d">Row 6b, 10b, 12b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b70ef09-6288-4a61-9c0b-6b3d027178ce">Describes the algorithm that applies to all observations within the container, unless overridden at the group or individual observation level.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa575819-a7dc-4043-ad84-1d6ce95c8b7b">Rows 7, 8, 9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a0d0919-bb63-4e2f-a517-75d44bd1afe1">The baseline Context Group allows for generic intensity, size, texture and other feature measurements, regardless of the geometry of the ROI (e.g., linear distance can be measured on volumes, or volume can be estimated from a linear distance), and being baseline, do not constrain the invoker from using other appropriate concepts specific to the application.</para>
                                <para xml:id="para_e1a80820-6ce7-44fd-ad80-00960d5bae8b">Different measurements of the same real-world lesion made using different types of measurements (different templates) can be correlated by a shared value of Tracking Unique Identifier. See also <olink targetdoc="PS3.17" targetptr="sect_RRR.5" xrefstyle="select: docname label quotedtitle"/>.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91fbabf7-ecd2-4d86-9c01-2fdf528ac2c1">Row 7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec84ec1d-b331-4604-8b00-7dc0200beeeb">Planar ROI measurements are those defined on a single plane by a segmentation reference or planar spatial coordinates.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e388018-a084-4830-8789-2aca475058d4">Row 8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f666f350-a4f1-41f5-b457-2f4525749508">Volumetric ROI measurements are those defined on a volume by raster or surface segmentation references or a set of 2D or 3D spatial coordinates.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e5dd0ff-8e30-48ec-8878-f4820e8e310d">Row 9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1f9849b-4c4f-4bad-976d-800ab017f460">Generic measurements include those specified on an image as a whole or by unconstrained graphic coordinates. These may be used for such things as whole image scores or quality measures, and for linear distance measurements, such as for RECIST or WHO tumor treatment response criteria evaluation, or angle measurements.</para>
                                <para xml:id="para_14d2d51c-ea81-4ee8-8690-833d8c7aabac">A Measurement Group is used to contain one or more individual measurements that are invocations of TID 300, consistent with TIDs 1410 and 1411, which both already have Measurement Group containers as their roots.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82f87e16-acb0-46aa-82f0-768cc05a326c">Rows 12, 13, 13b, 14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de8abf94-49ad-4bc0-b8e8-2dc451035fca">These Content Items allow encoding a flat list of name-value pairs that are coded questions with coded or text answers, for example, to record categorical observations related to the entire subject of the report rather than specific measurement groups. A single level of coded modifiers may be present, such as to post-coordinate the laterality if the parent concept involves an anatomic part.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1501" status="3" xml:id="sect_TID_1501">
                <title>Measurement and Qualitative Evaluation Group</title>
                <para xml:id="para_114cfb65-4682-44de-a13f-c1d06e3dbb6e">This Template groups measurements and/or qualitative evaluations into a Measurement Group.</para>
                <para xml:id="para_603f1d16-c3e0-4d64-8ce4-e00dc881174b">Each Measurement Group is identified by Tracking ID and UIDs, and may be described as having being made at a particular time point.</para>
                <para xml:id="para_0707a5ac-1bc8-458c-b2ee-72289f6e123a">Measurement groups may contain various common measurement modifiers that are shared by all measurements in the group, such as method and finding site.</para>
                <table frame="box" label="TID 1501" rules="all" xml:id="table_TID_1501_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3aed916a-5ecd-4156-864c-342338106c58">Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_10711228-3f87-414f-adee-cb3b75652b81">Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c2afd5a-18b0-4d81-bc34-ae924d7fb130">$Measurement</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a5e95a1-bc37-4997-88aa-cf5b64863b8d">Coded term or Context Group for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba7d4827-9ee9-4273-b69c-4eb1d948b873">$Units</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6bf5ee9c-e1c4-4433-a427-e8a1c84c4336">Measurement Unit</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_785aa8e4-3ff2-4e74-b3cc-ef3233f203d9">$ModType</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fcc0f4aa-9954-4efc-925f-dd00adcda7ed">Modifier Name for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4baf3f86-28c1-4bcd-9a6c-6764901c1d79">$ModValue</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35e43552-7199-4cca-846d-de8aba9cdf63">Modifier Value for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8583a46-9529-456b-97c7-68b81550e54c">$Method</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e57cc26-774d-42f9-8b15-504ac5c70d72">Value for Measurement Method</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab0309c0-e7eb-44a8-a7ab-815eca997351">$Derivation</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e215292b-64c3-4852-97f6-b8c5030c304e">Value for Measurement Derivation</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_295ce1ce-0e94-46cb-ad94-b31db49604ed">$TargetSite</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26ab38af-40ad-4de7-a706-3870f4549901">Value(s) for Anatomic Location of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_140a3c9f-edc4-4f74-91ed-fef8430cbcd1">$TargetSiteMod</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c9c8191-c894-43a8-9add-31c5790580f5">Modifier Value for Anatomic Location of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_494d1c1c-bd74-46d8-b554-51d94742a30b">$Equation</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff062cbd-4c76-499a-b8f2-3548053c97fa">Coded term or Context Group for the equation or table from which the measurement was derived or computed</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_811e1292-2dcb-4c96-9321-abd8782d58d7">$ImagePurpose</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_afa350c7-6c39-4686-9cfd-c9e3bfa3d1e1">Purpose of Reference for an image used as a source of the measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24a9b682-2345-40fd-8c2b-d3eee882e0e1">$WavePurpose</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf8d79a5-6232-4639-bd0b-c77e8f4b85a4">Purpose of Reference for a waveform used as a source of the measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00d3f550-dacc-40d8-96be-6618415cc828">$RefAuthority</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a96603e4-6621-4d60-a087-0a42e1675033">Bibliographic reference or authority for statistical properties of a reference population</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af19b020-1c81-4573-8a00-dc6d4875be76">$RangeAuthority</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3149091-6bb1-48b3-ad3f-92cfcb1263b1">Bibliographic reference or authority for the normal range of the measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26256996-c091-40bd-b05d-38cf4a596a4a">$DerivationParameter</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df55d66b-9d24-4b82-8bf7-ff2605a54ba5">Coded term or Context Group for Concept Name of a derivation parameter</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08f963aa-00db-4bdf-9193-25daffad6e86">$DerivationParameterUnits</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b23a525-7eec-43e4-ae13-2effb6abd6b0">Units of derivation parameter</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0dd32851-a699-4d15-bebb-49b4dfaef49c">$QualType</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e828fe4-608e-4138-9372-5d9bb263b04c">Evaluations encoded with code or text responses</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c828bdfd-5b37-4af4-b7a9-9980c8b80f0e">$QualValue</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b40c043-6232-4d55-ad1a-cf891ec37622">Value of evaluations encoded with code responses</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1fff0c20-f6bb-4fee-8126-834660372131">$QualModType</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be25cd89-1be8-4ee8-ae4c-e625e0352e6f">Modifier Name of evaluations encoded with code or text responses</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b29214d-4a83-43dd-b434-4aae92592ae2">$QualModValue</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0c2b5df-b354-456f-aab0-2fe7f9375c6e">Modifier Value of evaluations encoded with code or text responses</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30516722-fa2f-4ea6-a56d-e870bf5fb569">$FindingCategory</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cfa9c9f6-5a01-4403-9b67-31218c7495e5">Category of the finding</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2e6781e-d015-4b25-836e-ed3b007634f4">$FindingType</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4abf161f-5742-4eba-8593-3031d8c0b706">Type of the finding</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3185e69-d385-40be-9d6d-0098f450efa9">$TrackingID</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb9be0ef-447b-49c3-995a-55e383d4f6c5">Value for Tracking Identifier</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_77bc5b40-c0d2-43f5-b214-ae5b658699b9">$TrackingUID</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c64959d-0d9d-4618-ba9b-220851ea440f">Value for Tracking Unique Identifier</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_cc679c37-9059-4b23-8836-3fdf0046a0d4">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ea8614a5-4694-4cee-be77-09a96c05720c">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_9ad71d29-1bd6-44df-b282-0b50a7388d3b">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1501" rules="all" xml:id="table_TID_1501">
                    <caption>Measurement and Qualitative Evaluation Group</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6cf3eeee-bde3-41f2-9cd2-d2a7c2fd15de"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a753304a-333e-44a2-b1de-6a357d827b35">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9b361704-3515-44f8-bc8d-8b4c7bbd3bd6">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3f88f263-0608-4fda-9eb2-629f8f00ab90">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_472206d9-066c-4c71-9bbd-2114d729f75b">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8720acfb-54df-451c-b098-dc55f146f6bd">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_789f5c1b-14da-47e9-8b2d-91afa2c9f6ce">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e618c06c-2ed8-4cc8-86d8-570049b0290b">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_50c97dbc-38b3-4780-8666-e80d0e960f39">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e553294-3b91-4308-9dd5-cab5993fc271">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c32e330b-8290-4360-a024-2bf2bd867a5a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7999f1a1-e780-4573-be47-540a1718b75b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b3f4a25-408c-4c4d-8be6-1d600c149895">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1cc549fc-754a-4eaa-a2d3-6291e8750353">EV <link linkend="DCM_125007" xrefstyle="select: nopage">(125007, DCM, "Measurement Group")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fcc4ffad-bb0d-49ad-b7fa-967199743ff2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b73d3ca3-05ba-48ac-9eab-b2f0e7f0df78">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d35f0bc7-9294-4136-b82c-6d7c23f702b5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03be1fcd-9618-44fa-a630-706e645c6bf3"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff2f07db-7c32-467f-bb12-fe971b409b38">1b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a520a91-4690-4471-b566-ea4eb14543a2">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8115766b-050b-4d5d-852f-e4e581690f79">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f646f123-7cea-4bca-a381-029fde6fc59a">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3542061-a8ad-4a26-a63f-ca9784b061bd">EV <link xl:href="http://evsexplore.semantics.cancer.gov/evsexplore/concept/ncit/C67447" xl:show="new">(C67447, NCIt, "Activity Session")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ddaa1d32-2d8c-4385-ba25-45d27dfc1f25">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3ae01147-d156-41b1-b8cf-80bae1934d65">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_023d7269-c7d0-45a6-a134-2c3f9b57a170"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_32313350-d035-44c7-a8fc-f965aee4cbf2"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ddaac84-49f0-4baa-a14d-52bc193361aa">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65bbf1bc-0251-4aae-bc3a-3a9822f4d2c9">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b01d0e13-7f02-4ebc-99b4-89b1df2fde10">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3fb3bb8e-989b-49ae-be8a-ab9ea3da91f8">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b9137bb1-ac0e-4ca8-9a41-cb26310c8d38">DT <link linkend="DCM_112039" xrefstyle="select: nopage">(112039, DCM, "Tracking Identifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_df71057a-37f3-464e-8a00-3bdf491ff512">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_756e9632-f176-4ae1-a440-ab00f01dcd2c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e68eac1a-2bd7-49f2-bf2a-e9cc72e18b16"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae1aa583-9e2a-44f5-a429-0a5a9a52c20b">$TrackingID</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c95f2e03-ddbc-422c-a9cb-5b0e4fc1c254">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da5e6932-bf43-44a4-938e-ac0c4b59398e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab41450b-9a57-44b3-a073-5189b9a1a7e7">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a1db4e4-6c27-4a6d-899e-84e3b03c4909">UIDREF</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86f7fc17-109b-4be9-b280-75e7ff74bf08">EV <link linkend="DCM_112040" xrefstyle="select: nopage">(112040, DCM, "Tracking Unique Identifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_89fbfd41-6a43-4dab-bf53-300d3424bb25">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b73b7f0f-b17f-4f69-b42f-fc99b82a8053">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79b85cb5-6190-4869-ab85-fcfd27f5f661"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0aae53a9-4e88-4004-b47d-4f60ea6e939e">$TrackingUID</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fab955ac-b691-4a37-9ac9-2bcd02624547">3a</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6dd2ead-d537-4326-96f3-9d889772883d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_49ff284c-407f-4da3-909c-7f581d3b6493">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58b75c0c-6d55-4334-8e5c-1f9b4838f372">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aaff68c9-8445-48d8-a590-9aaa4a231ae8">EV <link xl:href="http://snomed.info/id/276214006" xl:show="new">(276214006, SCT, "Finding category")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_221f32e1-c5d4-4ac6-a784-ca0624fd3d32">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8afef6ae-61f3-4c75-8fe2-7b341a35b82c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f97b6e82-bb10-45e1-91ce-d822f96ade0d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ece02f3f-7ef4-44ca-bbb2-41a29b0bef69">$FindingCategory</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9763279f-53e8-43d1-93fb-258bb884ecd4">3b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac4af6c3-1dcc-4524-8692-d4695beb2066">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd27ece4-d1f8-4748-8a12-89a095d269da">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3dff116-887c-4d97-8e6d-0778055cfb5a">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba69039d-644a-4d45-80ee-6671449d6a6c">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_649c608f-4175-4b85-a096-755a335e4d50">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_29ae51ab-d234-4bc1-bf27-1f8dc7e556fa">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cca1812a-ebe6-4087-bb4e-5229dac621b7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67353bf7-139b-420c-89d2-1e6f09417848">$FindingType</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22e44b23-abc9-45af-9498-597a62ef13cf">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9cc64775-2655-4f1e-80b9-533bc6a4890b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c8f186e-bdec-4cad-9d7f-ef02fed767c6">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46d1d522-0ecb-4608-8c37-a43d6482f14a">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a792ad4d-8aa9-470c-9cea-a5731f1a4443">D<xref linkend="sect_TID_1502" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_89a7b9c0-3c88-43b8-82ee-3e6589c7fbc8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_71ef31a4-9567-4dfa-a1b8-2d601cf8d07c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8dd345d9-6f9c-4e7e-9958-6ca13d3bf742"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_94bcaef0-dbfd-43bc-9386-fbf03ef452ba"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c44a0c8-9258-4995-91e1-3f46aa24d770">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_501037ec-1221-4b1c-94b2-82093c28b3d3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d992da02-4142-453d-a978-2d8ab3e1e218">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa9c7e9f-b868-4184-9649-113f6df4ec11">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_003ea871-caac-40d1-8e0a-69d7c4718b6a">EV <link xl:href="http://snomed.info/id/370129005" xl:show="new">(370129005, SCT, "Measurement Method")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_65bc8307-9aff-46b2-8ae1-c86bdefb237f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf708f2e-3bcc-4f8a-9c10-3d4ad78a9172">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a76a4b5-691b-4abe-85e3-09b554066ddf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51eaf4a4-59de-4be5-b179-b5fe0dc43b8f">$Method</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a8ae8df-8db1-4297-afe0-87492c317968">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f8804cd-418b-446d-b169-973edf58a108">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67e2ac2d-62c4-47d1-851c-975e33b49fed">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10aafc9b-8a7c-4870-a7fc-9863c6b66294">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9028dd1c-2abe-42ad-87b0-856631408028">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8da462cf-805f-49c3-96a1-02ba17282af2">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c6be973f-4bd0-4215-8873-eb873818f9fc">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b6876fd-469b-492f-a329-64dd14debf7f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_526b30cd-2f97-4b80-9030-869a17830d0c">$TargetSite</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f860cc6-416d-46c8-836a-5e80abca618f">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_306eec13-3d32-4b5c-825c-3e586d217a22">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_77be977d-9917-43dd-b849-db12f56ef4f3">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b526ae26-977f-451c-8e9c-2e2ed15aeda7">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a30899a9-0aa4-4e53-abe2-06d3cfe85b96">EV <link xl:href="http://snomed.info/id/272741003" xl:show="new">(272741003, SCT, "Laterality")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f7c33a73-53b9-48e0-9b0a-c404a65cab80">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ead57b8b-c70f-4cbb-ac9f-6335948dd0e7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d736311-57c7-49f9-886d-90388eaaf3f4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c57dcb2-6435-4f8f-9cb1-95f62d899d07">D<xref linkend="sect_CID_244" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dde61ad1-a0c9-4dc6-9069-4c768d4171ea">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_afa45c22-7da3-4c76-9b36-cd7b6f906886">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba5f5b89-c124-4e2c-8387-12f16229a18e">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a1a182b-f0f7-4eff-addf-cb286a86056d">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb3ad489-33ce-4554-97d1-811a832de150">DT <link xl:href="http://snomed.info/id/106233006" xl:show="new">(106233006, SCT, "Topographical modifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9a2ab6bd-9d65-452c-9226-f051d2d4951d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ba2e518b-b993-4350-ab34-86868bfb24a9">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd52a4ce-703a-4767-acfe-3db75d9e72bf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ba1aaed-6d8f-4ad8-b384-115f8d29dc7d">$TargetSiteMod</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4a1aa89-117f-46de-830e-0ab9a75615bb">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e18517b-fe15-4cb3-9034-ea5b0cada37a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_14635e66-e794-4e61-bc63-ed8e28258caa">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d92111b-6f51-4680-b6c8-142e8af35cbc">COMPOSITE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4499bfa-740c-4992-91d0-f9b85faa222a">EV <link linkend="DCM_126100" xrefstyle="select: nopage">(126100, DCM, "Real World Value Map used for measurement")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e41e1ab9-5b55-477d-8db7-9c85b73743fc">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_83090c08-702a-4760-85a3-d00e9c76bfd3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d21b3244-a2c0-4808-8d69-3ed9088ffb87"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0bf559b1-b2e4-4db7-8abd-ce8d835edf72">SOP Class UID shall be Real World Value Mapping Storage ("1.2.840.10008.5.1.4.1.1.67")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b33a05be-68c7-42f7-bd86-6d6470e81521">9b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab65e77e-f7b7-44f7-b787-7d291226eb34">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_962d50db-34b3-4030-b42d-551c1e24e5a0">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a9e0c0e-394b-4eda-a822-686ac7efd9d2">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3abff2ce-c061-4a28-ad39-a6d878377eeb">D<xref linkend="sect_TID_4019" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85f6d6dc-25f6-4b25-9e29-ac9f71f4aa49">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6258721c-5fb6-4c30-8cba-7964df001bb3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_438dbcce-8231-4aa8-a2a3-7ac66e0d1f4a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d3b5e7e-ef77-4a23-be34-4d15d973aa5f"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0070816-76b0-470d-9de3-570be46bb466">9c</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c19295c4-38dd-4e50-8706-87d710876de1">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b13036d-b431-4255-829c-96304f3e904f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa74d651-e58f-416d-b2c2-4ad84c52e057">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_12de2a21-9e83-4671-b5f3-808da65d40e2">EV <link linkend="DCM_121200" xrefstyle="select: nopage">(121200, DCM, "Illustration of ROI")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e73053bb-33ea-4ad1-9195-6d64dfb2d173">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4b151a37-ef23-467f-810e-3fdef201154b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_deeabdb4-ce2a-43c5-a280-99cade0e1e07"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6ba08cf-be8e-41ca-8983-b1678065a42f"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e488327-ccf3-46ab-a700-fb2b68c49f6f">9d</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe676738-d128-41c5-8c32-be3078edcce7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad0f94dd-d2f6-499b-bcb5-49ee077ea2f0">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_20588b02-b2b9-45f8-93e8-103c4bcec4dd">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c14218d-ff9a-455a-92c9-fd8ec166d83a">EV <link linkend="DCM_130401" xrefstyle="select: nopage">(130401, DCM, "Visual explanation")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_03043cfc-538a-4d2e-8216-4fee57fd0024">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_80484d05-5972-495c-9601-26aa6843bbfe">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d097d9ee-c976-4361-9f72-240a2c5405bc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3edc3b48-a8b6-46fb-a053-470c6feadc10"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d5a36cf-23f5-4c7d-a5d7-7ee4322f1b03">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e58ce1bd-d0ac-448d-9b93-01f903241340">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6177297b-681a-4e6b-b8c7-2881cd7e0ba7">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_262cd8dd-5c62-46dc-9228-61b78178bd26">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f382802-3d6d-4d33-a37d-5208d882708c">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8e58ba2c-c810-4780-b9f5-3f7391d17037">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_680211e9-9f16-46b4-830e-f947d05bb711">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5faad4f-a65b-4bee-8c06-4b271b8f4559"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f39a1c62-ce64-4943-a3b6-165b144f07e7">$Measurement = $Measurement</para>
                                <para xml:id="para_793d2241-8a62-4744-babe-23d6f78f652a">$Units = $Units</para>
                                <para xml:id="para_92e6f6ab-8253-4199-b880-698e0b3764e8">$ModType = $ModType</para>
                                <para xml:id="para_51b7a3f0-cef1-41be-ac3c-7328c2a23cf5">$ModValue = $ModValue</para>
                                <para xml:id="para_0195d2d8-4704-46aa-847f-888bf183efef">$Method = $Method</para>
                                <para xml:id="para_a598a4cf-16b8-41e9-8da5-e45fee215ba8">$Derivation = $Derivation</para>
                                <para xml:id="para_a520ab94-54af-48bc-94ad-1c0c012b35a8">$TargetSite = $TargetSite</para>
                                <para xml:id="para_9136f165-0728-41a9-846b-3c467174949e">$TargetSiteMod = $TargetSiteMod</para>
                                <para xml:id="para_618a925c-b9aa-4e68-9be9-69035614020c">$Equation = $Equation</para>
                                <para xml:id="para_d2c54ff0-c4f5-4375-8838-fde39cb9232d">$ImagePurpose = $ImagePurpose</para>
                                <para xml:id="para_5db5f2d5-f0c9-48b9-8259-d2c2b7f6d44c">$WavePurpose = $WavePurpose</para>
                                <para xml:id="para_d16f9c46-d989-48e8-8655-1fc0d42caced">$RefAuthority = $RefAuthority</para>
                                <para xml:id="para_874803a4-4c0f-45a0-b22b-6ee636108a9d">$RangeAuthority = $RangeAuthority</para>
                                <para xml:id="para_5b19ea79-97de-4f5e-87c4-8a04ddcc3740">$DerivationParameter = $DerivationParameter</para>
                                <para xml:id="para_9b9c9301-94db-4c83-af7d-b1da9193fccf">$DerivationParameterUnits = $DerivationParameterUnits</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe31cfd0-0ce4-4780-aaa7-eaec116a88fd">10b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7013753d-940e-4092-bc23-55abc268ff8d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80f4174a-a81e-4fac-9333-06a8a1bddd77">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3f8d549-5b2e-4bb3-87b6-7ef1760c3de4">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e144bb01-a068-450e-9a9f-68975304aa86">$ImagePurpose</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_790eb5d4-5524-4563-8523-19519e646139">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7510fc8c-fb42-4790-8675-ad9dd9748131">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a62bde1f-bd3e-4b39-94bc-af9912cea925"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ce81373-33d3-4a81-a8ce-f1ffc89e05c0">10c</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00a43dba-8083-45f3-9460-92fd75b504ff">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_389d6072-ed07-460e-89ac-bf24cf4553e1">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54da7c3f-713f-4528-81d6-71d5e551cffc">SCOORD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79bd3703-3a6d-414b-a222-21c1d01f4685">$ImagePurpose</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b7145b36-d956-429f-bdd2-3041646bad46">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7488472a-a88f-456c-95dd-67dd7db899da">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51c7419d-7051-4f43-aa9a-d24eda290233"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_abbb5fcd-365c-4f29-babc-515564fc2414">10d</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6cd7dd69-be04-459c-8f30-241156fd980f">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f08b1a45-d33b-4fda-ba1a-daba9b2c4f92">SELECTED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c03d871-2eea-4422-91fc-ed4df2e27b4b">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9062efc-23e3-4bf3-bdd2-8459c68fd729"> </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4decf582-9fdc-4952-83ef-b13ab94177c0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_95267483-ea91-4fdd-a0cd-c5a33f7fd39e">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c9bf5d0f-286e-4fb1-b065-480e4b565e09"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_90ef13d9-8db0-429c-be95-592ff171a73c">10e</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_559cee77-c204-40e7-84d8-0fa2418bca5e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1665735-ade9-4057-ad41-b9fa584db044">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ccc6647-d9c5-4359-83fe-f8ca5a41d029">SCOORD3D</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d599de8-6e97-4445-9363-df257c3c105e">$ImagePurpose</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fdd0af50-df09-40f8-9dfa-911ef2354a71">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2b6b8235-c1c4-4392-ac77-25fb4e340345">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c60b7756-2020-4463-bb06-ecfd12989daa"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9645b24e-0d44-4ba1-9919-a443cf3242fb">10f</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4e52a76-bb92-45ee-955d-08eb4ce72f12">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30c55c25-c712-4a33-8450-6377eb2b3076">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b42ca300-85e0-4a1a-bbc5-1adcfd576749">WAVEFORM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c885e0f4-a70d-4ac2-a18a-bdb017b878f4">$WavePurpose</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f0d9847b-dc1a-43d9-87fa-540aa80defdc">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_213e7795-faa8-42e0-999d-5f6cd9f2f701">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_60bca958-e18b-430f-bc22-5a309c0b7d99"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a44180b0-8356-441e-9ea2-3a04c0bf4ac0">10g</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e6adf9e-4bad-40bc-b9c8-b1683770114b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8709a883-35c3-4990-b18f-af7cc3b013d9">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_faeaa1a6-9819-44ba-9fa3-a91718d67eec">TCOORD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_866398b7-b872-4153-aae4-306fe44bd89d">$WavePurpose</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d93cd573-6391-46ea-800e-762c7bdcf3e7">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5f3fe687-2f6d-4ed7-8bdc-01daa57a9248">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ed9604a-254d-4ac2-aad0-f3d54cecb402"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_539521ec-2dc4-4ed2-bffd-5c6b7c1e322a">10h</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8cc4e3f8-1073-4266-8977-3d5653a13c9b">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c9b49bf3-db00-447c-a566-03cb44945dc2">SELECTED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed536d4c-b256-4d04-a099-cecbf8116f75">WAVEFORM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_157e2928-ca01-4541-8b05-f721d2aab1ab"> </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c0863e1a-7954-4619-9652-22ae2fe9c769">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dd0e3a6e-6fb5-40f9-9869-07a14f41d048">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a441ec0-3528-4334-84a5-1f8815d87012"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_561fe520-579d-41cd-be3a-81f9167425a3">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67f4a30d-4f88-4719-ae9a-c8d5625d7f62">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65325706-0d92-4dba-8b41-c608cc87e86e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2acb5a0d-c545-4a1e-abb4-0913efdf34ca">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d360eea1-f8d6-4f6d-9f53-fc0aa814839c">$QualType</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1bd12891-64bf-4198-bc36-caeadd08e7eb">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d77d339-02e3-4ae5-b412-059bb6434e3c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4680e520-4539-4d07-91f9-446e6133607c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da4cbd66-66b8-4dbf-884d-50a12e848513">$QualValue</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72ef9da7-e5d8-4c75-a09f-a1a908ff10f2">11b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02f69756-3dd1-4043-bdf6-6a79eafe80fe">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06e88546-589d-4f5c-8634-3d0aefe2e8e6">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9cb382d0-78df-4814-a819-3912a4b35b42">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df69c26b-6bd2-4d3b-907d-15020b23c0cf">$QualModType</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a84e0089-23f4-43b6-9099-88ea1ee38b57">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_937056df-20fd-49e4-9d88-bd8930066f41">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1f60fda5-07ca-4a05-84ba-b4e2fd2867af"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7e61255-2b59-46e0-abd7-58a2c1e3a7f8">$QualModValue</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1288f892-e9dd-4b87-a348-511374eebcb4">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b19197ad-457d-4166-9ed9-3107b274508e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4dac1e8d-28a9-4e64-aa9c-0f8c6df27fc1">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e4a327a-8947-4705-8be1-0c37e8359150">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5514b42a-e6e1-4b09-a978-1509da4697bb">$QualType</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5a32cb44-a90a-410b-b406-9eaa87163b62">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_38c92490-44a2-4b42-9362-28f0d3f90594">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46ad3fe8-a433-4291-b8ca-0e657cf2fb25"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c0daa2f-4d73-494a-a6b5-a2e2f2bc0481"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_c6830046-1dab-4cc0-aaf8-fd119bd48c1e">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96280a7d-623e-4e89-a8a0-fd292a80eecc">Row 1b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e69cade8-84bc-4519-8b50-52ce0104173d">Identifies the session during which the measurements were made. The NCI Thesaurus definition is "time, period, or term devoted to some activity".</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_626354d7-f51a-46ac-9117-d6e798d955c3">Rows 2, 3, 10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8cda662-f6a6-48e6-b639-993d5d10a3fc">The included TID 300 contains an optional inclusion of TID 1408 Tracking Identifier as a child of the NUM measurement, which in turns allows for either or both Tracking Identifier and Tracking Unique Identifier Content Items; the intent of Rows 2 and 3 is not to send these Content Items twice, but rather to factor them out into a common location for multiple measurements, and to be consistent with TID 1410 and TID 1411.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c6031d1-d1d8-49c2-ac8e-4edb0e12cbb8">Rows 3a, 3b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_677438e3-51dc-4c5c-be25-4ee955801807">The category and type of the finding describe whatever entity (finding or feature) is identified by Rows 2 and 3. E.g., a finding might be a lesion, a tumor, or a reference region (as distinct from its anatomical location, which is encoded in a different Content Item (Finding Site).</para>
                            </td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1">
                                <para xml:id="para_d3de4176-5cc8-4b45-8203-27a4bd55e6c9">Row 6</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_a991a0a9-5062-4554-8f32-188e6058d31b">Finding site may be multiple when a region of interest spans multiple anatomical locations and there is not a single pre-coordinated code describing the combination of locations. E.g., when a maligant, inflammatory or traumatic process spans actual or defined anatomical boundaries. There is no requirement that the multiple locations be contiguous.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d2c72d8c-c530-486a-8fae-921ea3d8dc9c">Row 9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35e79cf5-dc82-4404-92fd-ad45d3b6ac77">The reference to an RWV in Row 9 allows measurements to be made in units that differ from the stored pixel values in the images referenced elsewhere in the Template. E.g., for a PET SUVbw measurement, the mapping from activity/concentration units in the referenced image that was used (and which may be reused for measurements in the future) may be encoded in a referenced RWV instance. This reference applies to any measurements in included Templates, unless overridden).</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f309eae6-38d7-4b5d-8b2f-99824b8133db">Row 9b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e144f14-016e-4b43-bc4c-adee8f4b0637">Describes the algorithm that applies to all measurements in TID 300 Row 1, unless overridden within the individual measurement at TID 300 Row 19.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_803ef479-70a5-4b30-b17a-ce8b1d5c60b9">Row 9c</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55681a28-5d4a-42ba-bfbe-4cebf1d92ee9">This referenced image may contain a "screen shot" illustrating a rendered version of the ROI.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22e989f5-7dab-44a5-9c03-b89b7adde360">Row 9d</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c1af412-0d42-4a27-8dcc-07afd2846cec">This referenced image may contain a visual explanation of how an algorithm produces its results, and may be a "screen shot" of the explanation already superimposed on the source image (e.g., a "heat map"), or a parametric map intended to be superimposed on the source image by the receiving application. The type of image and the type of visual explanation is described in the referenced image's own metadata. More than one referenced image may be present, if there is more than one type of visual explanation, or it needs to span more than one single-frame image.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_94a30c2c-bda4-4a8b-9607-7b5bc53d50df">Row 10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a18a5a5b-128c-48d4-a9d7-0cc334b9ff9c">
                                    <link xl:href="http://snomed.info/id/260753009" xl:show="new">(260753009, SCT, "Source")</link> may be specified for $ImagePurpose or $WavePurpose as a generic Concept Name when there is a desire to avoid having an anonymous (unnamed) Content Item.</para>
                            </td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1">
                                <para xml:id="para_5608bfbe-583d-4205-9620-8fca26ce6448">Rows 10b, 10c, 10d, 10e, 10f, 10g, 10h</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_bb5afb79-0999-457d-af45-5f22053440b8">Coordinates, image or waveform references that are the subject of this measurement group instead of, or in addition to, coordinate, image or waveform references associated with measurements in Row 10. Note that if an ROI is defined, other templates may be used, such as TID 1410 Planar ROI Measurements and Qualitative Evaluations.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d76683bc-f523-4ce9-972c-1a7c96c91435">Rows 11, 11b, 12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa3c719e-6cfd-45f9-ba69-33127346b4b6">Allows encoding a flat list of name-value pairs that are coded questions with coded or text answers, for example, to record categorical observations related to the subject of the measurement group. A single level of coded modifiers may be present.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1502" status="3" xml:id="sect_TID_1502">
                <title>Time Point Context</title>
                <para xml:id="para_5dc067f6-08ec-4a28-8a04-cb6a9b862a63">This Template describes information about the time point, for example, at which a measurement was obtained.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_087b9aad-c621-4d70-8f2b-57dcf147ce2a">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_44b7d375-f8f0-474a-b74e-8d409c0c4f1c">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_6f4263d4-ecb1-440f-be1a-6f86838e9cfe">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1502" rules="all" xml:id="table_TID_1502">
                    <caption>Time Point Context</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ea5efbc3-ccba-4112-bb51-837409ec9c73"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7c7dff37-8a3c-4b5f-8fe8-c39c2ecfded4">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_61e9ba6f-f9eb-4f05-8483-cf98e82ef57f">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a82363a7-637e-4a4e-a035-8dd623abba70">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c065aa2c-fdb6-4058-abdf-d692c1ee6f45">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_29ca6937-3ebc-45d1-898f-11f9d11f0834">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0556075d-59b1-4d2f-aab5-ea8eab43788f">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8056e9bf-f1bc-42cc-8a31-23b40301e16a">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_289df25e-28b3-448c-b01c-523c969498d3">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c40c4b8-d9df-414b-8a0e-c217bc6a0605">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61c63d2a-6d70-46f2-a8d0-09ea870865a0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9f2f334-f867-44b8-8b1f-083a5ff80e83">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ff955ad-524f-4fb8-8351-1f3c416202c7">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09c009ba-8205-4d5e-ba24-6e096bc1bd9e">EV <link linkend="DCM_126070" xrefstyle="select: nopage">(126070, DCM, "Subject Time Point Identifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c04653ed-190b-4719-939a-5a44f6a49631">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_897fd8ad-92c1-4b5b-8357-b7b27ca2bed5">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c229d8f-248d-43cb-9291-f8c7bd9d6718"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4b5f31c-d527-4e1b-9abf-f5c5a1586e9b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e49fba1c-4d4e-4634-a30b-2c130820265a">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c002fba-7c66-4c56-b923-e1ed6f92f02a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_71debeab-fad9-4399-ba0f-b6522e27359d">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e0d5c1b3-0cf8-4815-93c9-4ef81403b9e4">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25a86fab-7187-4deb-9c69-9fb0345f8647">EV <link linkend="DCM_126071" xrefstyle="select: nopage">(126071, DCM, "Protocol Time Point Identifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5585ec2c-3610-46ca-93ef-0640fcb5a7eb">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_55492822-b820-41ca-91b8-4eb9da5c7359">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_60f23d07-bc54-4e61-a41e-1f701ffc193e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fce40221-6859-4b0d-a6a4-03ebae958c99"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1eec7ed-3f52-4f76-9ec9-91beecbdb3a7">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_027d4fb8-f8ca-40d2-a963-29d5c280839b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6bda98e3-c204-451c-a6be-34b13119bb33">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd2c6aa6-2325-4be4-8a29-2634a97c9969">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d14044bb-cf56-48ee-b21f-c0cc5ea03088">EV <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C2348792" xl:show="new">(C2348792, UMLS, "Time Point")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a62e2d49-e05b-4469-be57-f7a796406c55">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ec7dea3-26cc-4e53-bef2-af0611375557">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36f9ee93-14af-4589-807c-34342420ebde"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3bc43a8c-fa7a-47f7-9892-d295175fba6c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72f6248a-2d3a-43e2-a0a5-9d789ba9d7a3">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_40e787eb-5e53-4b38-a1d3-99ab6c9c93b0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81cd391e-c8cc-46ad-ba47-ffeb9373a8f7">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ffd091a9-2437-4934-8a2f-608959605cca">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a03db627-3fee-4d3c-8b26-53420fd1769b">EV <link linkend="DCM_126072" xrefstyle="select: nopage">(126072, DCM, "Time Point Type")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e57e4da2-9051-4e5e-afcc-e567efd5da16">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cfcf9df1-ca02-4d99-9c48-5798dbd7f761">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d323298-44d5-4e31-ba47-e546df2e78da"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5350f986-cf4b-437b-a2e7-b579aa160368">B<xref linkend="sect_CID_6146" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61aceef9-54e2-4b6c-bf97-b1820eb2cf26">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4da11889-f9f6-42cf-af80-ff1284f92b2e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4f83ce4-4477-4f6f-bf3f-892eb37e9366">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b6b2b05-c1cf-47e6-88ab-c02a2b083ae2">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f38f6d9-84db-4ac8-9f7f-204bdb639d4a">EV <link linkend="DCM_126073" xrefstyle="select: nopage">(126073, DCM, "Time Point Order")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_db4c1259-50ec-40ca-b5f2-dee53e904650">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_17202178-632b-474a-99c2-43aad71960ed">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25e53873-aa3b-408b-8c31-16d18616a4a5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bcf20b92-88e9-4a8e-8440-2d8057756e86">UNITS = EV (1, UCUM, "no units")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9d4c0a2-9d3e-42be-ba2d-b090c8243815">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e48784f-98c3-44a8-8a2c-d5f0a7828827"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_41bdb9fd-180a-4592-b708-ca8016cfe27a">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d9c7e57-877f-4a5c-ac75-71054cb03101">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae8acb9b-1500-4290-8590-4211da954352">EV <link linkend="DCM_128740" xrefstyle="select: nopage">(128740, DCM, "Longitudinal Temporal Offset from Event")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8d8893f6-04ea-41de-b21b-4718fb123f9d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e3ba111b-6c44-4bc8-a4ec-51073d432223">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6bf7b1f7-b325-4ebc-9146-ecabddcf88fc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6c5d886-43b6-49df-a09c-61e0f02ce691">UNITS = DT (d, UCUM, "days")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3d6f112-f180-4b28-9c33-8971ed1b3403">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4ac4990-dba8-4aa5-abc2-fc71a8e55c19">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5aded4e-7632-49d6-ade6-405701948dc9">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cbc98f84-407c-4e9d-b85a-08841a941738">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_07fc2ba5-a55e-4185-832c-1f93a1c11c11">EV <link linkend="DCM_128741" xrefstyle="select: nopage">(128741, DCM, "Longitudinal Temporal Event Type")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_29ada174-455c-4574-8022-042a1cb7eb88">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_76c8f83f-02ee-4e9f-a01c-c560cdcf9703">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ca673da-9677-45b2-a59b-6b3e47eb93dd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b827b4cd-f23c-4011-a0f1-d88be658af3f">D<xref linkend="sect_CID_280" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_501fe256-5a06-4b04-b7ca-8f36c48ced12">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9c40ab2-80ec-4610-882d-d548df86a3e5">Row 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e52703b-8819-43a1-80d0-f95d9a255c6d">Usually the same value as the Clinical Trial Time Point ID (0012,0050) Attribute in the <olink targetdoc="PS3.3" targetptr="sect_C.7.2.3" xrefstyle="select: title"/>, though not confined to clinical trial use. May or may not be human readable, and not required to be a DICOM UID.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_048e1ee0-b2a2-46a6-9bf8-01833c7f74e7">Row 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1de2f279-7481-4ebd-9eba-40d77534a833">All of the subjects within a treatment protocol that are examined at a particular scheduled time point (e.g., "baseline", "pre-treatment", "first post-treatment") will have the same Protocol Time Point Identifier, but different Subject Time Point Identifiers. However, in different protocols, the Protocol Time Point Identifiers for the same conceptual "time point" will be different. E.g., the "baseline" time point will have different Protocol Time Point Identifiers in different protocols. May or may not be human readable, and not required to be a DICOM UID.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_90250868-2caa-40df-9a7a-6e572174325c">Row 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be58dfda-7187-4045-a2d8-3c4a4d902cba">Typically a short pre-defined label that has the same scope as Protocol Time Point Identifier (i.e., same conceptual time point within a treatment protocol) but is human-readable and understandable, e.g., "BASELINE" or "TP0", "TP1", etc. Usually the same value as Clinical Trial Time Point Description (0012,0051) Attribute in the <olink targetdoc="PS3.3" targetptr="sect_C.7.2.3" xrefstyle="select: title"/>, though not confined to clinical trial use. The Concept Name is selected as <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C2348792" xl:show="new">(C2348792, UMLS, "Time Point")</link> (which is <link xl:href="http://evsexplore.semantics.cancer.gov/evsexplore/concept/ncit/C68568" xl:show="new">(C68568, NCIt, "Time Point")</link>, defined as "a specific point in the time continuum, including those established relative to an event") in order to be compatible with external
                                    terminologies.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c997e50-ff6d-4aba-aa6e-cd1e4d751bc1">Row 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d93ce58-b017-4a7c-9cf2-764159761c48">More than one type is permitted, e.g., a time point may be "posttreatment" as well as "unscheduled" or "nadir", etc.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_292fa2b1-af58-4d99-84a0-7ddb2f475e0c">Row 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c729ab6-11f0-4ecd-b374-be68bd351aa4">The order is expected to be monotonically increasing within a particular scope of usage, but is not required to start at 0 or 1, nor required to increase in increments of 1 or even the same increment (e.g., to allow for retrospective insertion of unscheduled time points). In clinical usage, the Time Point Order would be expected to be temporally increasing, but in a clinical trial may be a randomized reading order rather than a temporal order.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9bf7261e-22bb-48c1-b0f8-f8a446fe21a5">Rows 6, 7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4afad95-8f68-4eb5-a1e8-e81a2e4295a3">Longitudinal temporal information may be inherited from Longitudinal Temporal Offset from Event (0012,0052) and Longitudinal Temporal Event Type (0012,0053) in the <olink targetdoc="PS3.3" targetptr="sect_C.7.2.3" xrefstyle="template:PS3.3 Section %n %t"/>, or may be specified or overridden within this template (e.g., if different measurements in the same SR Instance were measured on different time points).</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1600" status="3" xml:id="sect_TID_1600">
                <title>Image Library</title>
                <para xml:id="para_ee811db5-3d8c-4bf8-90ff-3d532465a1ad">The Image Library contains references to images and selected attributes describing them that facilitate analysis without having to retrieve the entire set of referenced images.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_24ae278a-ca23-4590-8b55-bcaed8288956">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_44939d09-8d8f-40b5-835a-e0c6671c085e">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_83a5ca25-9c00-4f04-b8be-bc17a55ced79">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1600" rules="all" xml:id="table_TID_1600">
                    <caption>Image Library</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_713fc774-4f5d-4578-a93e-3e1ae51da223"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1bfc11fa-d0a1-4cc3-895a-71fb2e6dadfb">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3391c44e-be65-40e3-bd67-58b428b7ccad">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_07b5a34f-472e-4d98-a5c1-ce00a349dfa1">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e1d01580-31e0-4e66-a236-78e86b19bcdf">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5ad5ef96-bde0-4879-9aa0-fd58a16b9c86">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b024c0dd-cb66-4282-9024-cca9d606b6d0">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73224d28-01c1-45b9-86bf-2f03b4536a71">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2eefae16-1179-4848-9c03-2064fc526c68">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_caf826be-d3bc-4cb9-8301-d057060f538a">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5bc32058-168d-49f4-9bf0-f69bca902a9d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_64209de6-1420-413c-a32e-5de230b6d455"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2d8e3b5-cbfd-4cd8-b513-e60b0a47e360">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b46ccc18-13f7-4c51-9306-8c4cc4bf2361">EV <link linkend="DCM_111028" xrefstyle="select: nopage">(111028, DCM, "Image Library")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f8cbd239-2c6f-4f9d-95bb-73e4161bfc9d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7adeecaf-c5ce-4ab2-962e-89dd85256f19">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e86fbb99-da69-486b-b798-42f653e1afc6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b04057c9-45a6-4b30-9a4a-adfb896a15d1"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8c6874d-daae-406b-985e-26a47cd1e85a">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_766bfd49-61fa-488d-b00f-6a7289dc02e8">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e595c669-d626-444c-b19f-049a140b3e67">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2466e01-4238-4bc8-8f2e-77449aa48e57">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cfa2d20a-9024-4490-86aa-49dce1407e3c">EV <link linkend="DCM_126200" xrefstyle="select: nopage">(126200, DCM, "Image Library Group")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4f8abe65-90f6-4965-b371-0e8643c810c0">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2f9449ec-c776-4cc7-8a6d-2ff1d7c67ad7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb6de9af-db19-4370-bac8-e260dc0cd1cb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_061c394f-6011-4d5d-b34e-f4ac15c6528a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_744b4ea0-98d8-4c64-a309-6a38cb2aaae1">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ebcc9fa-2a10-49b5-9155-c8b4c3501225">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fed9a267-3948-4a9b-bcfe-637b955e9df3">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa0ec91e-b837-4a9f-84d8-ac1df27f9281">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_34e17bad-0faa-482f-8450-068497479db1">D<xref linkend="sect_TID_1602" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eaf3674b-176d-470e-8ddb-a3f08afa1f91">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fe7f1053-160c-4e45-80c7-a2eed80c314a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70145031-f9e3-4810-ac1a-156e779f37ed"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b5294c6-0c21-4759-a106-23c8f602c39b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ccfb48b-66a2-40a5-b31f-4a05cdb7e99f">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ae8c2fc-dfcf-4067-b379-79cf85eeccae">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ca32cb7-b1b1-4169-9bd8-41084f169627">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0b107ab-265b-4969-ab5c-a9cf4e71480a">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c2202819-bb78-45f6-a04a-f5695020f164">D<xref linkend="sect_TID_1601" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_11403b83-d8b9-41c3-b80d-0f3599fd721d">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3ab82df7-43fb-457f-bffe-13393e39fac6">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5f7a06f-7ed9-45ec-a3df-bd36d639e598"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c63f6be-0750-4b56-9302-f10933796361"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d815be1-488f-41d4-aa50-6eb67a31e455">Row 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02f6cd23-22b0-4c28-a31b-576ad520ad48">These Image Library Entry Descriptors apply to all Image Library Entries in this Image Library Group.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1601" status="3" xml:id="sect_TID_1601">
                <title>Image Library Entry</title>
                <para xml:id="para_1c76f467-e2fc-464a-8cdc-16e4f28e7651">Each instance of the Image Library Entry Template contains the Image SOP Class and Instance UIDs, and selected attributes for an image that facilitate analysis without having to retrieve the entire set of referenced images.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_2098c493-781a-4d8c-9a86-3e0982f971c2">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_2795099e-d3ed-467d-9b1e-a8cad41aa639">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_7cf04516-758a-4c55-923c-907621763588">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1601" rules="all" xml:id="table_TID_1601">
                    <caption>Image Library Entry</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a5135852-5f3a-4b74-93a5-9310540776da"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_43a77c37-82cb-48c4-b5cd-a5b25d3ed5b3">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fa320429-d14d-43c5-8e74-729a0d50a150">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_51dc82eb-29c9-42f1-b85b-794b509914c8">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_57058fb1-c4ac-4d5a-b79f-2373c2dcd061">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e33c8ef4-063b-420d-b244-8228d48c03aa">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ca6e60a5-391c-46a4-bb3b-2040f843316c">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2b6d0cbb-3d1b-4957-9fb4-9312a8293077">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8b6b3783-911b-4f1d-99a5-dda05fcf695c">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_346435b0-7359-4b32-ae75-f049411bd86b">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb1ea4e9-952f-46e3-8fc7-fd5c03226fe0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6bf0b775-a4fd-49dd-a1ca-b67a0e1bacb9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26ac3075-786d-4e61-b625-df9fbc9bb050">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_580818df-6b53-4c1a-a752-45e4ca3dd415"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ad1795d-cda2-4a3f-ab6f-5718a9527078">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_35cac85c-d126-4862-97e0-723439d6da18">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c83f5029-e285-4f4a-8193-72882b9f638c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5c9171c-28fe-4d07-b200-46d95e809402"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6cd2d56-dee7-4033-81ac-103814659876">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc5a3ee4-70d3-488a-a601-ed489d36ea2e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cef22471-8855-48b0-9809-cd213441106f">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_111f2d30-b781-4e08-9dac-9c9fab95c699">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_486ed441-73da-41f1-91d0-777a173ed375">D<xref linkend="sect_TID_1602" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fc95364b-7592-4ad3-ac12-bc6fc30c5088">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a78ff7eb-6104-4729-9a17-abb2c555c4da">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8bfbb368-a8ee-4ecf-ba9b-71fb4fd16963"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a1ed01d-8599-4f15-be45-f2b0440821db"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d419df7-2ce8-447f-983a-feed9fed0c21">Row 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0da96db-2a33-4faf-8dc6-2dcc06f9e9d0">These Image Library Entry Descriptors apply to the IMAGE in Row 1 and override descriptors in Row 3 of <xref linkend="sect_TID_1600" xrefstyle="select: labelnum"/> in case of conflict.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1602" status="3" xml:id="sect_TID_1602">
                <title>Image Library Entry Descriptors</title>
                <para xml:id="para_27b8770f-8e07-43fe-ae1c-761d78ef09ed">This Template contains selected attributes for an image or group of images. The descriptive information may be copied from images or derived.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f7aca72e-fe9f-4b14-81b1-85f4f8819c66">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_b26e05e6-f3a0-4acd-a9a3-f663a34cb812">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_c15531f6-7d81-4141-a7a4-b88fff81a4da">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1602" rules="all" xml:id="table_TID_1602">
                    <caption>Image Library Entry Descriptors</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7f069724-1f6a-4867-ab87-47d1381fa467"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ce20a761-c78d-4c49-8035-016eb38fd456">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c911f58-acc5-40c8-a4bc-331282dbb2eb">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ecf89a31-3019-494c-9dc3-0a1e9b98af63">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3ad8b1a2-f369-40ac-bcfc-be7fcd35d24a">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_152e1259-860f-4fe4-b8fd-f63b54870bbe">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5e194209-a18b-4643-985d-dd39b16009ec">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_362976cb-3d5f-49e0-af0f-207b640a9b0c">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_68450086-2e06-4694-9dd6-d38f5a15d620">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_618b3b06-4103-4b2d-9314-fffa24858b23">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f2c08b5-f696-4832-9390-efcb39fc49ed"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d978b84-80de-4cfe-b4c9-acfc24d771b0">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f89b9ef8-6413-488f-ac2a-dfc18e911b67">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ea14a44-e977-4d3b-829c-6536d5170961">EV <link linkend="DCM_121139" xrefstyle="select: nopage">(121139, DCM, "Modality")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5d69ebfa-21c2-4379-a36d-89002295b3fd">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e702382d-ae74-4683-b06b-5fe98a8f5489">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48378613-f6eb-4c7d-9660-7197eb03d123"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f7d9f7d3-e3ec-4d85-91f2-f1640a1528ef">D<xref linkend="sect_CID_29" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39279139-a4c9-49f8-85a1-6874c400042d">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7391b16-4a00-48c0-8db6-f47aa9ec16d6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d55c6d9f-8fb7-4e90-b3b5-d6429203c6ed">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7cb793b7-5cbf-4323-a87f-2fbf3b18d44a">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06d739e4-9c1a-48a3-9b57-1f5f90c4b786">EV <link linkend="DCM_123014" xrefstyle="select: nopage">(123014, DCM, "Target Region")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9849eb2c-7763-4c2f-9814-1aa0313bfacc">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_048ac776-e4b3-4772-a543-e09f2fc1d8e4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_53c211b4-82f6-4ef7-a4ef-62be2de785ae"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_efa4681d-bc2a-45f6-90f0-777b52ddbea5">D<xref linkend="sect_CID_4031" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97d0e481-af6c-4b15-8073-3af68768a436">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_507540ce-906a-4614-893d-36d16eae7d2b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a64c882f-a0f5-4cf1-8655-03bbdfc91a5d">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29a12564-d181-4b80-a71a-b4d6b80fd0cd">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cba90597-b59a-4468-9f15-9678b9055454">EV <link linkend="DCM_111027" xrefstyle="select: nopage">(111027, DCM, "Image Laterality")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_015936ac-66e0-4104-aa92-0747c559a132">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b28cb745-5ddf-4171-85ef-907f99918b8c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_662cc87f-7dc8-4aee-bda3-0c4513f90cac"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0f5d4a1-2d8f-41bc-bb07-f0a0b32b371c">D<xref linkend="sect_CID_244" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f55aead-8ce2-4f9e-ac44-84d1453d83a1">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ae78957-ad4a-4a49-bce7-da4b562f75a4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1da86b01-a6e7-40e5-a610-de4f58a91377">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cef66cee-62ec-4848-a845-f8c28ba2dab6">DATE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d86eec58-d49f-4d58-a6f2-3b4baf0a569f">EV <link linkend="DCM_111060" xrefstyle="select: nopage">(111060, DCM, "Study Date")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0f1fb934-7f1a-4b37-aa21-1d09582e72d1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_35bff7a3-be0b-44c6-9000-1461ec08d818">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a64f0491-4d32-4647-a016-3f023fc2f049"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2dc246c-29fe-489a-b6b1-c69b2c5aa226"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_156437e0-7be8-4573-a289-c177a9412f32">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_278e840b-220b-4bd4-8324-89381c25d5b1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab31db58-77e3-48e5-9a25-d157445f48da">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10e328e7-e3b4-4cb1-ba8a-5651d85aa3c1">TIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7aa78a95-0183-486f-8c79-4529918a16d4">EV <link linkend="DCM_111061" xrefstyle="select: nopage">(111061, DCM, "Study Time")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5c7ee3d3-fffd-445e-ab33-4810731a6728">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_af211031-db57-4e6c-9951-f7daa9e09f7a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb006d05-9644-4af8-9d56-258ada7a0862"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7dee2a34-6b06-4ead-8fab-598a2b14ecb3"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f3e3718-ae5b-4cac-abf4-b8ebaf386d8d">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4f2989a-33d6-4b21-9b74-e43cbeaf5fce"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_284a7121-edfe-4b1a-9f04-3cceef17cd37">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d4c6ce3-ea80-4b43-b5d1-99d5f68244c1">DATE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a64a0d42-09e1-4739-bb50-254bc0107c9d">EV <link linkend="DCM_111018" xrefstyle="select: nopage">(111018, DCM, "Content Date")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_75c7bbb3-9e95-4b24-8d7d-9ec9566fe434">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a5795584-ca87-4b34-b9b1-ee6515dec598">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_683882f8-a5e8-4ce5-947e-dd572dc848ad"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8fd2ff4-e2c1-4564-a267-1367f397caf7"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2942d4f7-6704-4787-9cf0-9c2db9453599">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5db0cf5f-5d65-424e-a274-63e059f33038"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99c3def5-52cf-4899-acd9-895eb3b720a9">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3537c427-4221-4129-8120-44d601f6cab5">TIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bcb24d35-fd52-462e-a9eb-d2c2a6d0b15b">EV <link linkend="DCM_111019" xrefstyle="select: nopage">(111019, DCM, "Content Time")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8a353ae4-1e60-47cc-bb47-ff10d0615ba7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_25661f11-d241-42a0-b560-5294b997acef">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7f062df-e3b0-4ebf-9ec1-8e503c0e9c16"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5e0d677-8294-4083-b030-0b1c7ae8fe45"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4b271a2-47fb-4a49-9e7f-3c0fb20746b8">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3079f5d5-9159-4d62-b312-31cd59018e74"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b0de725-5d6a-4605-b224-e0f982212343">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8805a6dd-bbc1-4a06-b681-b21b92bb72ea">DATE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0fa45400-36f0-46a3-b97b-620bf172dee8">EV <link linkend="DCM_126201" xrefstyle="select: nopage">(126201, DCM, "Acquisition Date")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_644409ef-6cf1-439d-bd97-b174c05001ef">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f7c79e9d-70c0-40f4-b3c3-e4ec13a6b3c3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1477ca1e-9883-4f2d-b472-b4036dfeed72"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6af1fca-2e3a-4f75-a3eb-4925837a950d"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6adf7335-377f-4643-867b-5a2ce31b0632">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e59925aa-c641-4398-b5b3-fb7f8d120765"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96404de5-d8d0-4b5d-8555-cf87ce1176a6">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a5c6b39-93d2-4687-a52b-b4811ab36d36">TIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2a1f223-8ac6-4fa1-8004-dd1becf92510">EV <link linkend="DCM_126202" xrefstyle="select: nopage">(126202, DCM, "Acquisition Time")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c3689937-6d35-4ab9-bf31-c7025013f08f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d58b1376-b6a9-40d0-b703-bfce51515d49">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e40b9b7b-b4fc-4dd9-9bfd-8b6d0fea02ab"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4356dafb-e95b-4c7a-96d0-16ab4c80970d"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5cad7333-882a-4af2-9410-d129f3463de3">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ee4a8d9-4a57-4b76-b582-328fa2839861"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d2f5e18f-83d5-4aef-914b-b14dcd678e26">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35f80d0e-5c49-4b49-875f-db32c0dd57a9">UIDREF</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a97b4812-7ce1-4f6b-931d-50a973622048">EV <link linkend="DCM_112227" xrefstyle="select: nopage">(112227, DCM, "Frame of Reference UID")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a30afcc-4eae-4cbb-8548-7b3cf1a05b22">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_07f3b5ed-935d-4bc5-9e99-eed685d8fe28">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30408711-9694-4d1a-994d-7e7d5fe3714d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e68e42a-7066-48cc-805b-66e3c85e309c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f304eccb-9d30-4e2a-9aa1-43880e857d42">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e02deb6f-c4d8-40bb-a73f-088758e009d4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1da319cb-8401-48b6-9034-ace8aaadb9f6">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b11d0187-3edc-4744-86af-a3484a77dd3e">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3c5ff18-e0c0-4d19-8d43-c4767d4d4543">EV <link linkend="DCM_110910" xrefstyle="select: nopage">(110910, DCM, "Pixel Data Rows")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_af42cd3e-fb8b-4efe-8c64-47b9b7dcf706">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fd8b20b5-cebd-4cfc-893a-c6c78c82dd88">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c2d00f9-faf0-4931-8ab3-d1c62d85efc6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d95f500f-4e32-4534-929b-8402165cc37f">UNITS = EV ({pixels}, UCUM, "pixels")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8728f46-e605-4d58-80fd-2331922ca682">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_644f022d-2f1d-4b7d-a2d0-3f980868f73a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a94c56e7-a17e-4865-867d-7198f8730f57">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5039786-36ae-4cf8-bd93-51766a4e76df">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9bfa68b3-b197-47d2-90f6-9bc1000939f3">EV <link linkend="DCM_110911" xrefstyle="select: nopage">(110911, DCM, "Pixel Data Columns")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_65dc46f7-dc5a-460c-be51-e23f1defb681">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0353047f-f741-443f-abda-42611c3b3129">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f7f890c-1346-499b-b707-81270e9ce9fb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f7d9153-aa46-452e-956e-a58b282d568b">UNITS = EV ({pixels}, UCUM, "pixels")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72e692e4-05ce-4180-9b23-1f2eab5a4a4c">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8042f0f2-06f8-4f7d-b6e4-d1632425b2d8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ada3352-602e-414b-85ad-5fcd90fb0a76">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_910cf484-2772-4c37-88e1-eb6bfb022fce">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1064e2d4-6c97-4ed7-af76-9f82c148322e">D<xref linkend="sect_TID_1603" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c39bdbd4-2e8a-40a9-82ab-62584aba033b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ebeff99a-b23e-47b9-9bc5-dae7df490da4">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c48da39c-4927-4b27-bd46-284d290275b1">IFF Row 1 is present with a value of "CR", "DX", "IO", "MG, "PX", "RF", "RG" or "XA"</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_057dccfa-7840-44c0-93b7-e26887ce521f"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_069806a4-3aee-4a4b-b3b3-534b87cf74c1">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3260b1cf-bba3-4947-ba70-52185ea316e3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98dd24a9-0bbc-487d-b7b2-a838f9a3588b">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8503d5c0-1c71-45ea-b991-978887b3da3c">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e8ade51-79f2-4b0c-ba95-fa8f14f6399e">D<xref linkend="sect_TID_1604" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ed6694f0-bddf-4a41-9fcf-53cafe3b52c1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_099ef4eb-647b-48b6-97d2-5e2443c0a00d">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75a3ecce-aac6-41cf-ad3a-92b2a868b90e">IFF Row 1 is present with a value of "CT", "MR" or "PT"</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e7ec800-dd8d-464b-8f87-5578129b4179"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1748670a-f631-42ce-a92f-3e002073765b">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dccb8241-564d-4cb8-890a-ed9f7b5723c6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c08159b-dde7-4977-93c3-3e914534bd5a">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21040918-b3a0-414c-a403-a6cf2a1a4485">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d821de5-b413-4fd3-bb6d-f98094ed5c7a">D<xref linkend="sect_TID_1605" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0133eddb-0e04-46f2-899f-3e3217d7ae47">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5ae9d932-9ebf-4f55-9900-2f95f03cc193">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd8faa49-ef39-483e-90c4-f3d68675d783">IFF Row 1 is present with a value of "CT"</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9869589e-aecf-44dc-8c87-9a60b723c20b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7658a875-ebd9-4dad-be91-351f830a32ef">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82f24a3a-2015-4e55-957d-bd278e61986b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_126cd805-5781-47ef-97b2-65f669297eb4">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8615d7a7-7043-441d-8edb-06dc7c5aac07">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85c43980-a584-465f-b984-94c2923e100c">D<xref linkend="sect_TID_1606" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1548e02e-e3b4-40d4-ae97-e81492fccac9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_58a1f012-0485-4622-ade7-dc16d8d7c689">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c07566b8-8373-49ad-b609-8dc793fb57d9">IFF Row 1 is present with a value of "MR"</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f43e66b7-dd1b-4f45-adf8-e91e139104ea"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1ad36cc-3b21-4a96-bb87-ce581d0ed4f5">17</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3c14441-8fcf-4a58-a8eb-bc910647a4a8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b85d5ae6-c898-419f-9bc2-d166d7e63623">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73be8005-6616-49ca-b479-0d62b528b43e">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_481cf0d3-5b71-431b-a993-5a0fd22f2075">D<xref linkend="sect_TID_1607" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e2d34cef-a6b5-44de-901a-f73777064816">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ba71536-77e9-48cd-bc67-60a9a27581ba">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5202ab52-4535-4d40-a285-19b7eabc63f5">IFF Row 1 is present with a value of "PT"</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e541fb43-0592-45f8-b18d-a8a706ea2f69"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_0b8bda71-ce9b-40e6-ae73-b1fac4476cee">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ceaff75-391c-4a19-b75a-fa8a0995430d">Row 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b508907-3391-484d-83af-e2e3adbb8a24">The value of Anatomic Region Sequence (0008,2218) in the Image IOD, or a code derived from Body Part Examined (0018,0015) using the mapping described in <xref linkend="chapter_L" xrefstyle="template:Annex %n"/>.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1603" status="3" xml:id="sect_TID_1603">
                <title>Image Library Entry Descriptors for Projection Radiography</title>
                <para xml:id="para_5df46815-9377-4578-bbda-b6224d64fe9c">This Template contains selected attributes for a projection radiography image or group of such images. The descriptive information may be copied from images or derived.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_3714e3e7-0151-422b-9e06-ab8be475669c">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_e961d404-a410-486d-8aa9-d425128ea8eb">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_c5cd61e8-d101-430c-8ac1-0ce9e9e93ceb">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1603" rules="all" xml:id="table_TID_1603">
                    <caption>Image Library Entry Descriptors for Projection Radiography</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3b86817d-6979-4682-8b78-096a8a6b3afa"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bcc4da96-f5a0-4e2c-8da3-24854d06de9a">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1bcce8f5-150f-41ae-9a2d-23eb9e746470">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f5c77ee3-3353-4052-a2e4-520f953582ad">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_05dfc679-67e0-4944-bf6b-76c2213e0f97">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_db5d1c0d-04fe-4d75-af76-ba258a93edd3">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7d7a1024-4b31-484d-97b3-47a76fbce065">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_be5280d2-1409-49c8-8267-e7adc5b898a8">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_46aafe31-c818-4258-b4d8-4e27978ecb01">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e98999a3-ee29-45c3-8d23-a7b223fc63dd">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31c40ce4-a976-4a5e-9d99-bbe5e271e588"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4519c36c-a0bf-4709-9d08-de473b6fcd05">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1f173dbf-2300-4730-9a00-c3e325f2cd2e">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57e3835e-e5d4-4a29-9adc-7d5e4a9ae85a">EV <link linkend="DCM_111031" xrefstyle="select: nopage">(111031, DCM, "Image View")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1600ae35-8ac3-441c-94c2-0964702b11de">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_641033a4-cb12-43f8-92ac-d32e57425a7b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3ac2a82-7a4d-4c73-80b2-e8b7e0d8176b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab8607e6-5b9a-4a47-84e9-b78e902bc876"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63f585d2-452e-45d3-98e5-599866122da1">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_039115b1-5485-4031-a23c-1950a7b70e53">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13d965fb-4b63-4a25-81a0-1c75577f47b2">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74cfafed-703f-438e-9078-58c70ab92c08">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f610806-16d2-4ec3-8b4a-1de002dfc644">EV <link linkend="DCM_111032" xrefstyle="select: nopage">(111032, DCM, "Image View Modifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c3865749-cee4-46c9-addc-b85cfc3db563">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_58a9fe33-96ba-4448-96a2-a9c47dc8fb0e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_164d0263-5c9b-45a7-8db8-e8f696ccbc4f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e4443c2-54d9-47ed-b111-9a06887cdf29"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_195fce50-9897-4d36-ac67-a7b7e6bb8a3c">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7fd297ab-c5f9-4a4c-9500-3aeb31394d47"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7dd41845-9e89-4bc5-a321-aa35d084c125">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70af59b1-6704-487a-bd21-ecc96e6f289f">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_060d847a-4e73-4d63-b595-e3e63a16ec8e">EV <link linkend="DCM_111044" xrefstyle="select: nopage">(111044, DCM, "Patient Orientation Row")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_022b3e7b-b1e2-4ed2-a4d5-873b22a3c554">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1f8c365c-692b-4eba-912c-83e45f6e27a7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b71276ce-087e-4f97-bb02-1468f17b568b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb373478-d63e-47ab-8ce8-d18e2001a34e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98f18042-d5fe-4e6e-8919-34c2e082a244">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93ff1b87-8240-4c9b-84e5-93e082ecbdc3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_092f6bd3-b600-4c00-a83f-18ff4c7184e3">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c42aab89-98d6-4b5d-aa87-2c7ebc2539b9">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17a48035-e68f-4055-a70e-ca7f598befab">EV <link linkend="DCM_111043" xrefstyle="select: nopage">(111043, DCM, "Patient Orientation Column")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6bf9884b-4bc3-4d4c-b04b-76ca990aafc1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4af6573c-84ca-4197-ac8b-bf795f2233be">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b883813-dbdd-4620-b44a-e785942bd610"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b8eec03-f424-4c29-962b-9ae11b2efed9"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27be1d08-febd-49f6-b8b4-9c4896747741">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93362fda-1073-41b3-a930-f24e06ecc6ce"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a464664-c75f-41f4-acd0-b5037c559f8d">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e580f06d-1db5-4849-9c7a-0b13792d7b87">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0894c98-b957-4b4b-81ba-e8f2b913e344">EV <link linkend="DCM_111026" xrefstyle="select: nopage">(111026, DCM, "Horizontal Pixel Spacing")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_012dc81b-a76f-4dc1-971f-1583f1064b23">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bf8f1aa0-d3ff-41a9-b108-806bfdca1464">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c19ac87-026a-4d8c-8e6a-edd8bfb230a2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea35c3e4-0a42-49f5-b760-aa23a8a9e733">UNITS = EV (mm, UCUM, "millimeter")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_232a24b6-d399-4218-a960-a0102529287a">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_364361dd-fb63-426d-9b98-25900af09bf5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36df9117-6de2-4df7-8968-5383f884aa5d">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac464c73-87fc-432d-b886-176caae412a1">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e99e5c2e-a78c-4444-89d3-27ccd651ef8e">EV <link linkend="DCM_111066" xrefstyle="select: nopage">(111066, DCM, "Vertical Pixel Spacing")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4517d388-e4a8-49d5-b0bc-56770d048351">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2db120ed-d561-4f68-94c8-ab3e721f0480">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4154c864-4cc3-40b8-bf34-8722d09038b4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee574f48-a453-483d-993e-2a3b4e326581">UNITS = EV (mm, UCUM, "millimeter")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1820f53d-e1d3-4097-bd89-8c920bf57382">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d7c6ec5-9e1e-4523-aa1c-c158227d0202"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8f15e32-97b2-4e0e-9e4a-bcca98d3ca86">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5798fd47-6ee0-41bd-8f39-4564d2754a96">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c2003a1-a6cd-4775-b216-b50e954d074c">EV <link linkend="DCM_112011" xrefstyle="select: nopage">(112011, DCM, "Positioner Primary Angle")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_41e516a9-e073-4867-a07f-718ef5647cfb">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_108bbc63-dc1c-43a2-9c27-13fa073c949e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_679514a2-7bb6-4712-acc7-820906b92944"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a5a8493-8264-47c0-997e-5c9e74ee4ff2">UNITS = EV (deg, UCUM, "deg")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa7f4c3d-800d-4035-95bd-032050b0fb77">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04cc0c4e-9fb7-472d-9e95-ac7a96c8ffef"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fad642e8-e362-4c9f-ace8-9f422e629bbf">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31332c3a-18d0-4358-b59e-ec765aaf86a4">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_921a3c3a-dc4f-42c6-896b-dcce65d2fec6">EV <link linkend="DCM_112012" xrefstyle="select: nopage">(112012, DCM, "Positioner Secondary Angle")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1f670ae5-430c-4501-b352-817ab406c01c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bca90686-bcd9-492a-961d-7fb9f93c7709">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd0e8035-fffe-4af8-a238-f95f418a3c1b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ac71f89-12a8-462d-83d1-e5cd42a29cbc">UNITS = EV (deg, UCUM, "deg")</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_dd0edd05-05e9-4d87-9dfa-92898c1e1855">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2273707-1460-4767-9a77-af66ee411a58">Rows 3, 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9f0332f-aacb-4d8c-83fd-aa36390d82a6">First (row) and second (column) components of Patient Orientation (0020,0020) in the Image IOD. See <olink targetdoc="PS3.3" targetptr="sect_C.7.6.1.1.1" xrefstyle="select: docname label quotedtitle"/>.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86b6b46e-1632-47ce-85d4-520f8d99163d">Row 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1206f164-9b5f-481e-b34f-5e883699f7e4">The second component of Imager Pixel Spacing (0018,1164) in the Image IOD. See <olink targetdoc="PS3.3" targetptr="sect_C.8.11.4" xrefstyle="select: docname label quotedtitle"/>.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc9e6963-066c-4a83-b0c9-c3c8b4b14311">Row 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a03aae36-7195-4ac6-8255-7c0f668358db">The first component of Imager Pixel Spacing (0018,1164) in the Image IOD. See <olink targetdoc="PS3.3" targetptr="sect_C.8.11.4" xrefstyle="select: docname label quotedtitle"/>.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1604" status="3" xml:id="sect_TID_1604">
                <title>Image Library Entry Descriptors for Cross-Sectional Modalities</title>
                <para xml:id="para_443dfe9c-807d-4cf1-98b1-bc88923036fd">This Template contains selected attributes for a cross-sectional image or group of such images. The descriptive information may be copied from images or derived.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_16f7dd3c-7496-44d1-a9b9-56a77cf2bf51">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_90671376-33df-4f12-8f32-9d6555acf5e0">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_e82d0046-6dcf-4f07-8201-a0cde04f373d">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1604" rules="all" xml:id="table_TID__1604">
                    <caption>Image Library Entry Descriptors for Cross-Sectional Modalities</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bda0ceb7-f4d0-4dd7-895e-e767a0031301"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_abd0f3c0-8a9b-4f13-ab32-da0423793bdc">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_74c72875-0a96-4dc6-8fb6-d3755193673e">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3a891da1-6f02-43b4-91cf-51221927d8a7">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_640b51f8-5c02-4508-8904-90376e7f7a14">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7adb1bb8-f826-4a2d-b840-97358b0d0e4e">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8a597138-2302-4fa1-9320-652f464438f0">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_975e3782-73b6-4561-ae12-7fffe23f7b4d">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f183400d-95a0-4c31-90ea-b49857fbf6de">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2075179e-6291-459a-b532-0236528744e5">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d321603b-aa5b-4001-b56a-fbc4b37af417"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70fb6039-dffb-4d0d-afdd-936275d4a1ce">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d83eb28d-6880-421f-8bc9-1567d4306359">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0605a52-f49f-429e-9fcf-dfa3b567ab10">EV <link linkend="DCM_111026" xrefstyle="select: nopage">(111026, DCM, "Horizontal Pixel Spacing")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9ce470a7-1cbf-41b1-870e-941f52e1db08">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c69cf7d1-3c43-4bd1-b341-390911d3dd64">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c7b25db-c3cd-4b70-ba4b-9f670d8e147f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2541bc5-1f76-4ac4-b1b2-4bb7e8c5aed2">UNITS = EV (mm, UCUM, "millimeter")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4a85be2-2b9f-4194-b879-c5b4fb024b75">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_407a17e1-3a1b-4c76-9af5-5dc4fbf2574c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cadef7ae-e259-4b78-8435-181d42e5754d">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_071fae9d-4fbf-4a8f-80b7-d7c94945dd99">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d166e48f-eaed-49ca-98e9-8024577e2458">EV <link linkend="DCM_111066" xrefstyle="select: nopage">(111066, DCM, "Vertical Pixel Spacing")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3314a9b3-187a-4abf-b019-dd553bee2459">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_812227e2-4c19-41c8-ac0b-aa74195f3d9b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cba992be-d96d-4937-9e7d-17f69dbbb830"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_53010689-ab88-4fb0-b4d3-08f603c56006">UNITS = EV (mm, UCUM, "millimeter")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0cf04be0-e28d-4c3d-b6bb-9fa19f9e9c7e">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7daeb305-6bfa-4a7a-9efb-3b09ef0dd06b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e90595e4-2bdf-467c-8fe2-cb803a4a61b1">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_28fcc7a3-2738-49cb-b59e-1cb4f90fa1af">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1332362-935e-417a-aaef-e91c9b57735d">EV <link linkend="DCM_112226" xrefstyle="select: nopage">(112226, DCM, "Spacing between slices")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9366ba52-071b-42b7-8ccd-085e0d5cbebc">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2bbfb106-d143-46b5-a94c-df067e1b47cd">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57334b3f-5c00-4c84-a137-fb78c2b450eb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a6e4538-98b1-4827-b196-170c75fcfb7f">UNITS = EV (mm, UCUM, "millimeter")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c3f4bc48-ca75-49ba-80cf-9ba27350b8be">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d03b7f8-ae6e-49ff-81fa-708bd49f7792"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dea5fcc6-a525-491d-a08d-4d5c2b327477">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4c77131-b167-4807-ba00-4811ad5a28f4">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3fdbac06-1f9e-4eb8-b49e-d26a54de9e72">EV <link linkend="DCM_112225" xrefstyle="select: nopage">(112225, DCM, "Slice Thickness")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bb6bcc18-dad1-41ae-b3ab-5da375070d52">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6a63a646-27cd-4a67-8bdd-5d14eba0f638">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dbc6340f-26f6-458d-b07d-5a18ada08e6f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad7f0859-d5b9-47a1-a0ea-85f81a59286c">UNITS = EV (mm, UCUM, "millimeter")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f447552-f769-4295-bab1-7bc9d1f180dc">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88e15787-b694-4d00-9e70-e5d827f07e45"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9da6045d-0f20-4654-8f63-96dc1c0e53be">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c0e7701-1001-4539-a35e-1ec96d9a0709">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24532a01-9efe-4392-9a83-e142521e1481">EV <link linkend="DCM_110901" xrefstyle="select: nopage">(110901, DCM, "Image Position (Patient) X")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b04460fd-edb5-4c95-b8f2-7ca366728b87">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_310ffa5c-f49c-4b6b-98ac-3041c5bd6a2e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4eda1375-ea13-471e-b34b-c0baea5a9493"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_951b55d2-8ec6-43ed-b73b-14b09b661762">UNITS = EV (mm, UCUM, "millimeter")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_360b9663-7a0f-4bea-85ec-e3a7a8d613da">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_650238f8-a6f8-4923-b2e7-c78cbde4d536"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7279137d-c4f2-4fc4-847c-29a918b000c8">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6421aaa9-98bb-4dc3-ac39-b5d85c20cafc">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b49d09d-86af-472d-800d-d6bba0e87648">EV <link linkend="DCM_110902" xrefstyle="select: nopage">(110902, DCM, "Image Position (Patient) Y")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c39cdf34-1b97-42d8-b6cb-60d55c345f23">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7a8568d6-27b2-4cdb-8b64-0c8c883cee63">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c3e383f3-3778-4745-a59b-c8ee3fa56c7e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dfd92eea-95b6-46b4-9101-c8cb535e07a2">UNITS = EV (mm, UCUM, "millimeter")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48af337b-3b66-475b-8ba3-4c9025df85df">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_33cf4f6d-9671-42ea-ad6b-93e3e4ee510d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_45c642fb-8628-4f82-ab00-b2c552e45b92">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ec374bd-3879-4470-8d44-14c1fded2bc3">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e75f6311-bf7f-4fb1-a76e-a8f26a5b519b">EV <link linkend="DCM_110903" xrefstyle="select: nopage">(110903, DCM, "Image Position (Patient) Z")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5dd48b39-637a-4879-b3be-9d566524a556">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fe173a95-0ee5-4fc6-a452-6a42a321a7c4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9e87ee0-f754-43d0-8f9e-143e9674559d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ee2dcf8-7a96-487f-9ad6-0327d0050dbd">UNITS = EV (mm, UCUM, "millimeter")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed46b50d-0b19-4257-8bfb-f28d2ea0a484">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_940e850e-f473-4626-8f63-3cccc222bb50"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb8d5637-8b3a-414a-9009-8cbc9ada57fd">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4b32ca3-9289-45e0-ac48-cff0b9ee0db4">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_459b62da-cae1-418e-8828-be3e3305aa42">EV <link linkend="DCM_110904" xrefstyle="select: nopage">(110904, DCM, "Image Orientation (Patient) Row X")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8c273a19-0000-4ca3-8b9b-a0348acb4e92">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0591dc63-06ae-478a-b689-8c33196b970c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d588132d-3078-4482-970d-47ceaf595e97"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f1399bf-8954-4955-bdef-db57ed9a3226">UNITS = EV ({-1:1}, UCUM, "{-1:1}")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_877c9453-f1eb-4635-8e82-fba1c5766c92">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1bd056e-e086-42a8-88b2-8ee78c32e977"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b21d6fb-119f-454e-bf02-c39491ee9a86">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9866b02-c988-47e9-91ab-9e5d4475076d">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b03d3a8-bf23-4652-afaf-8ff76f538cb9">EV <link linkend="DCM_110905" xrefstyle="select: nopage">(110905, DCM, "Image Orientation (Patient) Row Y")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9f3a8478-0673-4a84-9ce8-93a21acfb190">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1006afe4-457d-4c2f-b100-8f587dadd058">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f801ee88-0493-46a0-8fa5-3f0530d46a30"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3798e04-6b65-415b-ae69-776055847736">UNITS = EV ({-1:1}, UCUM, "{-1:1}")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98b8129b-8182-460f-b375-f955dbd5487a">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd8c071e-9fd3-4049-9b52-c7a19bf03442"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c3cc41e3-5ee5-4165-98a8-dc15818d0fd2">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ebb4de92-1c5b-4bc7-b232-344998d91332">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82d280e5-7d19-46fe-b06f-0db71e53826c">EV <link linkend="DCM_110906" xrefstyle="select: nopage">(110906, DCM, "Image Orientation (Patient) Row Z")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5d5fcf10-3acc-436b-a5d4-a64a6a577eaf">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_49affdaa-da42-4f7f-b8f6-049ea5bba990">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5ac071f-0870-4a0f-9b91-97451c0dc44f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e9a9a2d-d7bc-4e85-8f58-0873a1a2e636">UNITS = EV ({-1:1}, UCUM, "{-1:1}")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ebb94fbb-7e4b-4a7d-8a0d-917d56fcbb40">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_233e94d4-9c99-4a8c-b8a3-7e0e1d502703"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0a14661-09eb-4f1b-ba99-e6565e744ed8">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f2b81ac-c322-4198-84ca-ac783c8d1119">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97710cb0-03d3-4fed-bc42-0c7f42f9e4bc">EV <link linkend="DCM_110907" xrefstyle="select: nopage">(110907, DCM, "Image Orientation (Patient) Column X")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2f3346f1-4573-490d-a875-6a17f2076705">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_963f4c7e-9865-456e-afc0-60b863f8b4e2">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a53486f-cdb3-456c-aa76-c332dc5403c3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c6cfff93-eeae-4ce0-872f-97d605aeb347">UNITS = EV ({-1:1}, UCUM, "{-1:1}")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9475b624-4e8c-40ae-b3bb-3be5f44633ca">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5abe31a8-c3cc-4419-8317-ffe727e057f3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5dddd4a4-e9c8-4699-bfd8-cc53cdf22be7">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_33dbacde-b165-4135-ad62-ebe2353447ed">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d6b697a7-9182-4754-bd1a-bc9d0d1ad95a">EV <link linkend="DCM_110908" xrefstyle="select: nopage">(110908, DCM, "Image Orientation (Patient) Column Y")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cb43201e-9054-4668-98e2-e015e819739f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ec6af27f-256d-4365-92a4-9eb04dd8fc77">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad824be2-7bfb-47b4-b44b-b9b5bc23df4e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0af9f77f-0621-4f72-a8e1-0838c1a5aa12">UNITS = EV ({-1:1}, UCUM, "{-1:1}")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9290a949-ab22-4915-8842-c9095d596079">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_971df277-82a2-4ff0-a5d4-7755053749c0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ccf90678-291b-402a-b628-7478ddb8f373">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f6480d5-9a27-46ef-800f-c5bd235c486a">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b2dee01-3202-4a5a-b3cb-75017d1b99fb">EV <link linkend="DCM_110909" xrefstyle="select: nopage">(110909, DCM, "Image Orientation (Patient) Column Z")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8d67c84c-d92b-4595-b3de-b98655d6a2b4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_526233fa-9165-4e9a-a557-9ec633e79487">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_18d383ee-624a-4cbb-bbae-9eb25600bcfd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9bee2c6-5d23-4b03-9239-4f6fe3ce9ea7">UNITS = EV ({-1:1}, UCUM, "{-1:1}")</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_e1a96803-e5c4-4885-b9e5-a5bf07439066">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b47db5a-f9e5-4ec7-b4b2-7430c86f7734">Row 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52b7402f-b0d9-4cf7-a51a-3cc2253971f5">The second component of Pixel Spacing (0028,0030) in the Image IOD. See <olink targetdoc="PS3.3" targetptr="sect_10.7.1.1" xrefstyle="select: docname label quotedtitle"/> and <olink targetdoc="PS3.3" targetptr="sect_C.7.6.2" xrefstyle="select: docname label quotedtitle"/>.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_511134ca-56ba-4af5-bef5-be6e839406ff">Row 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_49652884-f1ea-4160-bd33-a7342bcaeb31">The first component of Pixel Spacing (0028,0030) in the Image IOD. See <olink targetdoc="PS3.3" targetptr="sect_10.7.1.1" xrefstyle="select: docname label quotedtitle"/> and <olink targetdoc="PS3.3" targetptr="sect_C.7.6.2" xrefstyle="select: docname label quotedtitle"/>.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1605" status="3" xml:id="sect_TID_1605">
                <title>Image Library Entry Descriptors for CT</title>
                <para xml:id="para_44048664-0e0f-4bf5-ab8e-fe0f6e907a7d">This Template contains selected attributes for a CT image or group of such images. The descriptive information may be copied from images or derived.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4f86b7f1-37bd-40a0-9ccb-327c3d5d66b8">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_9f2f4125-892c-4794-8e0e-db15bdfff08c">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_bef6ce25-3f3f-4c71-9176-401444a58660">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1605" rules="all" xml:id="table_TID__1605">
                    <caption>Image Library Entry Descriptors for CT</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_18ed2969-ff45-4ae7-bb72-a412354f7b9c"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_12986526-564d-4d79-b9ea-771104079cfe">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_74453fa1-5920-4037-b690-a8eb0559d269">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3a3cb38b-445e-4dc5-bd8c-55274c8c33b4">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a837729e-038a-4bc1-a89c-25cc1d46f185">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_39362686-05ad-4d93-a35c-e26f93f7c6ff">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf04fd59-2d82-4a6f-9f8b-5e31b5f1cf76">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_180403ab-5e19-40fb-81c4-e70b15d0114c">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_54a78f4c-c91d-4d59-acf4-491b944a1def">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa048668-80a8-43bd-9226-767bb1998786">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a088cbc-8c90-49b5-951e-8309bc92f8dd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2da1000d-3ac6-4721-bb15-5b770ace6c1b">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0b0030a-4eb6-4f63-bd43-778a95b2ca3b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_76b7d007-6b36-4cee-9949-072dac55ba98">EV <link linkend="DCM_113820" xrefstyle="select: nopage">(113820, DCM, "CT Acquisition Type")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b12ca445-5b53-47ae-830e-111812972b55">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e69a1aad-bcf3-42da-8046-8c3b39f917ce">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4937d963-944e-40f5-ba99-8bcbeed5475d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_15bf5ddf-9a8b-4d77-a57c-93d35eeba53a">D<xref linkend="sect_CID_10013" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8597e6fb-d8a4-4ad6-86d5-1cf6b43bde63">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd7268a1-e6c8-4c69-992c-1325f7065df3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_428ace29-cf5b-4e2f-9659-8f849c1fec9f">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd028dcf-9520-4b72-89c8-414512cd2ac2">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7cf0b014-2472-415a-9989-d7b71741d87a">EV <link linkend="DCM_113961" xrefstyle="select: nopage">(113961, DCM, "Reconstruction Algorithm")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bd2328a0-45d9-4a75-b221-d23a47e5aa0d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_28e6b918-c21e-4d34-abc7-8cfff9f97075">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67ad0373-5425-4666-b752-debefacbaf74"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_629d536c-3a25-4dcb-892a-5120157e1484">D<xref linkend="sect_CID_10033" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_1e4c9517-772b-4dae-8349-81eb88313854">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_896abdce-938e-40e8-bc05-6d666d8d4e3b">Row 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f7fd8e56-e1ca-4c28-b3b2-6b2630ef0e53">A code derived from the Value of Acquisition Type (0018,9302) in the Image IOD. See <olink targetdoc="PS3.3" targetptr="sect_C.8.15.3.2" xrefstyle="select: docname label quotedtitle"/>.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_870ac5c5-e39a-416e-ba29-4dc9e2260936">Row 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c09b68bf-1337-4321-97f7-e24e328b5c64">A code derived from the Value of Reconstruction Algorithm (0018,9315) in the Image IOD. See <olink targetdoc="PS3.3" targetptr="sect_C.8.15.3.7" xrefstyle="select: docname label quotedtitle"/>.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1606" status="3" xml:id="sect_TID_1606">
                <title>Image Library Entry Descriptors for MR</title>
                <para xml:id="para_9ecc9ad0-ee38-487f-84b8-f1f815731171">This Template contains selected attributes for a MR image or group of such images. The descriptive information may be copied from images or derived. Specialized coded Content Items allow more precise description of imaging sequences used for interpretation of multiparametric prostate MRI.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_b145dfc6-e8a5-4fff-af6f-bf20be081b69">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_0fadba55-1f10-4283-b586-1b3db226d668">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_c29d019b-a287-4a68-b551-145772b204c3">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1606" rules="all" xml:id="table_TID__1606">
                    <caption>Image Library Entry Descriptors for MR</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b86f2bcb-89f5-4143-8c92-9885eaab6f56"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a5cc9616-c9f2-4ff0-8085-6b90d77bfea4">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_458dcde2-3c48-4f04-b9df-b89a17814a9f">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4c667b0e-0bed-4f39-84f8-e1e47a5ccc6d">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9c063452-5de0-44f1-a9ed-124e7fb6c437">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_be2dbd6e-8090-4811-94b0-8a4bef3c97c3">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5cfe7daf-e03d-4897-8e5e-38e42a25f703">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b46b12c-b7b2-4c30-8bc4-8936f8ad6ecc">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a30d2c5e-0434-422f-ad16-1b0bff397b3b">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d11c9e48-ac1e-46d1-b71b-7d794bf18e25">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5069bd55-3dec-427d-99df-93e7a753b20b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_284793dd-4e24-47a3-a869-ea6b16c5f6b2">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a56b4fd2-620a-4055-bd71-34d71afb633a">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_20727b85-1744-47ea-a6fe-d9ea113469b6">EV <link linkend="DCM_128230" xrefstyle="select: nopage">(128230, DCM, "Pulse Sequence Name")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f303f13f-318c-4e04-b868-2f2d36041c35">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_784932be-21c9-4bff-bc42-02030baeb3c0">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e59234f-c752-40dc-897f-cad9c9d114e3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ee031d5-a397-4065-8375-acd40e424f71">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_727777bb-41d1-48e9-b61f-1cd35620d6fc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a7da6f5-b6dd-4692-941f-55212b9308ba">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46683d14-1cb1-45b0-9b31-717fa3cd5f8b">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7208720-d877-488b-9cc2-c3d1cff92e0f">EV <link linkend="DCM_130542" xrefstyle="select: nopage">(130542, DCM, "Magnetic field strength")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0cb4bd1e-3415-4372-97cf-1312f2cf6f6d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b7c26692-9c14-4d6e-9afc-cc8fa498aeaa">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52443452-65d9-480d-bea5-5f0a4c7efe74"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2976b758-1019-4be8-a6a5-908b3afec7ec">UNITS = (T, UCUM, "Tesla")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bdcbe7b8-abf2-4947-8ac2-b2265c44f672">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e1f9589a-5036-42ba-b0e9-88aeac4456f2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d220737-8691-4dfa-8435-f05689de6497">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c630c96-d072-4e56-9e2a-78113cf6ed37">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a3cdf25-f1b6-47bd-a76f-a453c346ef8b">EV <link xl:href="http://www.radlex.org/RID/RID10813" xl:show="new">(RID10813, RADLEX, "MR coil")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3cd46f5b-df80-4411-8c36-a0b77b9067ef">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_26864fd1-2642-4717-b501-0dba6414762a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2778c727-1fa1-47d5-a025-f3532d2d7235"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10a80342-a7c1-4e8f-af4c-3841292d4fd3">D<xref linkend="sect_CID_6349" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3fdce382-b18d-4183-99ec-405b9fccc0fd">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7672d952-015f-45d3-a66b-38db84e606fa"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e24e206-6eed-4e01-8865-b7f036626bb3">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_14af85ca-255e-477b-9ceb-510eca1ba950">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_648521ca-5f09-4d9f-98b9-924152458366">EV <link linkend="DCM_110852" xrefstyle="select: nopage">(110852, DCM, "MR signal intensity")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c2fffc60-cfc5-4734-ab62-593791c26432">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_02f6372e-21e7-4fe3-94cf-e6bbda2d8683">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e8441de8-9081-4b28-b2c5-97e216b73f70"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5af051d-1d0f-4e00-a9fa-a60e37fb914f">B<xref linkend="sect_CID_6311" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_56fcb8da-1278-4153-89fd-c4f00aa3a136">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a09f69e3-f94c-4f73-aae8-94b6eecfae1c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_389ec6b0-e4d3-421a-8be8-fc480c5db2a3">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_23df7432-65fc-4e03-b249-e6ff79063ff1">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83137ec5-633e-40ae-b352-7f5a7c875794">EV <link linkend="DCM_130546" xrefstyle="select: nopage">(130546, DCM, "Cross-sectional scan plane orientation")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1eb39317-c8f3-4fda-9945-09c933c99b8b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_82e0931d-8034-43eb-b3c9-bc3969479abc">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9427e0e7-2b42-44ca-a14f-ec6cfd322b66"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_94a0ca70-976b-4ff2-b3ff-caf236447dba">B<xref linkend="sect_CID_6312" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0aa7872-a5d4-4592-8505-4fa48f847a41">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5477d10-9cac-4c44-bf7c-957ae752138f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c2d942a-9a11-44a0-9bc3-09d2b8275982">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f203c8d9-d7d8-4130-82b0-af41c7edb74a">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d07ad4a7-44bf-4b40-b4a7-bc00f4439682">EV <link linkend="DCM_113240" xrefstyle="select: nopage">(113240, DCM, "Source image diffusion b-value")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_320daad2-23b4-4eea-8226-4f0b1f1c94a2">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b5e38256-3ddc-4bbb-8617-4c6259437657">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_270cc9f5-353f-45d8-93d6-44e6bde52d57"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da7e7a15-4ecc-4f05-9da8-4fd82eb73082">UNITS = (s/mm2, UCUM, "s/mm2")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e46ea30-be00-4dce-a9e4-7a5212faf10e">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a26a92f0-e725-48b3-97d9-216dd6722aac"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_932d0b9a-0392-401d-9bec-21b4cc83825d">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73701239-1e05-453d-b127-ed9ef0f3784b">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bef7c766-51cd-48fc-9c3f-35a7f59ec5ff">D<xref linkend="sect_TID_1608" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_755750db-38e6-44ad-9c29-6acda0462031">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f32fed71-b35a-46cf-b18c-e5211ab31f66">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_feca9429-e662-4675-8b5a-f668ff1f5dbf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f72baa60-8e1c-49b7-88b1-885f5556b103"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_6b4b30b3-00f6-44dd-9a43-b63209d88da8">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a156b016-7000-4adb-95f8-070f37688132">Row 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9892402-5025-4703-917c-6e21424165c3">The value of Pulse Sequence Name (0018,9005) or Sequence Name (0018,0024) in the Image IOD. See <olink targetdoc="PS3.3" targetptr="sect_C.8.13.4" xrefstyle="select: docname label quotedtitle"/>.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eaf36197-123a-4fbf-96cb-f9007afdcc63">Row 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_653ee8fd-d070-4e2a-adae-83131638e0b4">Multiple values may apply when entry descriptor corresponds to a parametric map such as Apparent Diffusion Coefficient (ADC) map, which utilizes multiple b-values from a Diffusion-Weighted acquisition.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1607" status="3" xml:id="sect_TID_1607">
                <title>Image Library Entry Descriptors for PET</title>
                <para xml:id="para_8757771d-3325-4465-af5f-e365cb0dcc00">This Template contains selected attributes for a PET image or group of such images. The descriptive information may be copied from images or derived.</para>
                <note>
                    <para xml:id="para_872cb329-e03e-4212-9816-d10049f0342a">The content of this Template is similar to that in TID 15101 NM/PET Protocol Context, but is in the form of an SR Template rather than a Protocol Context Template, and the Content Items are not nested as modifiers. There is also some similarity to TID 3307 NM/PET Perfusion Measurement Group.</para>
                </note>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_95b93c59-a5df-45a4-be90-3cc9fc6184cf">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_b7d6b999-3de9-42eb-970c-af150a6dfa3d">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ed876c7f-8c6a-4e8f-a165-afe784ea6299">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1607" rules="all" xml:id="table_TID__1607">
                    <caption>Image Library Entry Descriptors for PET</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2f405261-e510-4283-8b74-1140b71e08c7"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ab60e888-00d7-4040-9e83-d7bc144d2709">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0da1adad-8b79-4b82-9f20-d188d906b02d">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f3474f32-4538-45ca-aa85-accc3153476c">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_176218c3-494a-4de5-801c-15eeecc70fd5">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_acab390c-bd81-432c-841a-05fde71ab819">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bb565f11-1948-4f95-adb8-0f6e0614f2b2">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6fe70009-05b6-4f5f-af09-d35d51a682f3">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bed078a4-7dc5-4a0e-8764-117e3700c651">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42521206-a5d1-4332-a452-b8e95aa909ba">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e79e5b76-5ab7-434a-a9f0-8767e485787b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_318f9116-4cf4-4cbc-a13c-4348ff91c5ae">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38ef416f-6052-430c-9660-de5b527c65f9">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_974a8e25-ae4e-48f3-b8ec-f9b20b05eca2">EV <link xl:href="http://snomed.info/id/89457008" xl:show="new">(89457008, SCT, "Radionuclide")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cc09263d-d44e-4215-b2c5-7e67386e0887">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a07dff21-b3b3-444c-8928-38784ad6a95c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42d92018-c359-43b4-97e6-8e945bb5424e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_525ae12a-5e0d-47d7-8fb3-9bf028a26785">D<xref linkend="sect_CID_4020" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_66bc03d4-edd1-4089-a130-c48840b955ef">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98d65662-738a-4203-adc1-7db9d443db6b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e437c6b6-0db2-4f46-a7a7-c3a703729e27">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fcab7301-b5d6-44b3-9292-6604b7f403c2">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a76b3eb1-62b6-484a-ab75-b5d1b2a9b354">EV <link xl:href="http://snomed.info/id/349358000" xl:show="new">(349358000, SCT, "Radiopharmaceutical agent")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_868f8ca6-8bbf-47dd-83e1-4371608424ae">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8309ddde-3c16-4bd5-91bf-255914e1109a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43dfefc0-5701-416b-87d7-b8309cc470d0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69fffba2-10e0-46b4-9ede-839324c8a30f">D<xref linkend="sect_CID_4021" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e0dedde-ec48-42c3-948c-7c514b7caaca">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4173197-feb8-4a3e-be29-485316b82da2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97e7b8c0-8087-4fe1-acf5-8a56fc73d8dc">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3dae6c66-256a-489b-952d-de8e2859c3ec">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1755fb95-afda-4ceb-a4f7-f3a7c5b9b0fc">EV <link xl:href="http://snomed.info/id/304283002" xl:show="new">(304283002, SCT, "Half-life of radiopharmaceutical")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_03e89c90-2fb0-4268-b956-1ffc57de4e45">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0b3f8549-07d2-4d40-9d4d-9238cab11e08">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a413e27d-c93c-44b8-a561-527a77a83438"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81e5287c-b495-4afb-a0b5-6d0e827e1a4d">UNITS = EV (s, UCUM, "s")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7a4cb367-5fba-46ba-906b-1d459451077e">3b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e353c12-e9a4-433e-8ee3-23b608eedb69"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd6de213-6615-42e9-bf4f-e0e6df92c90f">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97f36bcc-dd85-48c2-8efb-b1d7048774dd">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3039422a-6cb9-4d4e-b73c-0940b50d51fb">EV <link linkend="DCM_121022" xrefstyle="select: nopage">(121022, DCM, "Accession Number")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c434f3d9-ab24-4915-9081-047efd254713">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ef9e2d55-6bab-42db-9f40-edc4723f5ede">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b45c5be8-d419-4cc0-945b-82872f507f7d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f598fc9a-9667-4461-aeef-bbb8c5a30134"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10a19c6f-c3f9-4248-8026-c23967973534">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d46a6b48-90d1-4ac6-8ecf-23d510235fed"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce7af05c-aeec-4cbb-b8cb-613e3c5ccf11">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8e00f4e-b172-4910-89d3-954ae978cd15">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4a1c688-1bc4-4838-9f30-9c66bc3b5770">EV <link linkend="DCM_123003" xrefstyle="select: nopage">(123003, DCM, "Radiopharmaceutical Start DateTime")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eeb5b3e7-38ed-4f62-89a4-c74f6f776e67">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a297a7a0-eb10-4218-b0f0-465c41aa8d10">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f159b28-f98e-4570-a4e1-aa11af595f7b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4dc7b393-aa38-4f29-9b50-e367442fcd26">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad6acad4-1e52-4608-9ca8-baf11378fb76"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5bb35671-7df4-4c67-b925-24caa924e2a7">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1036d55-6a08-4a61-81ee-545bcbdf4a22">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67882427-b1b2-4737-98d9-96343632abdc">EV <link linkend="DCM_123004" xrefstyle="select: nopage">(123004, DCM, "Radiopharmaceutical Stop DateTime")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b99c516-367e-46ac-ae67-0d78d45d655f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2200db31-6957-4df0-af3c-bdfb336c2023">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d19c572e-3361-4c80-a6c5-58722722e9c8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c0109a4-1753-4a23-8be5-6b6ff3c5216f"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_178bf07b-889a-447d-ab8a-1ad627cd0925">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_504a8e90-d930-4852-a790-29f5b5d8ce1a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b3b1bf7-5b98-4867-98cb-3001bcf48e9d">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8799adb6-9ead-4c36-bd4e-ab274cde59d3">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eef276a8-bcaa-4079-a372-54ae410f43ef">EV <link linkend="DCM_123005" xrefstyle="select: nopage">(123005, DCM, "Radiopharmaceutical Volume")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_063a51d3-3515-4970-8233-a9c1dd7d84a4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_83a692e9-5339-4695-8ff1-7e903472e9ba">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4df6817-0183-467d-948b-e55f0183e120"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2073ff02-a2d1-4a5e-9d8f-8980195ea464">UNITS = DT (cm3, UCUM, "cm3")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91230338-4fbc-44be-871b-a40b7e20b054">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae43bacd-649b-4128-831c-252ef28e7d9c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43fbb90a-b340-4b14-a544-93055551dcb1">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ed1f4b5-dd15-4ca9-99c3-b9589a9da26d">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11365024-167f-46e6-9a01-2f379d003775">EV <link linkend="DCM_123006" xrefstyle="select: nopage">(123006, DCM, "Radionuclide Total Dose")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85c62f7a-0629-4488-9677-f48a8a00633a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb764399-9530-4050-b105-b68dd2266e06">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec2f09bf-ad32-4639-a460-84ba15bd6632"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_095ae827-d3a9-4750-aede-9fd37e1bbfd5">UNITS = DT (Bq, UCUM, "Bq")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e82f319a-bdd4-4f7a-bde8-a4f7035f8dd7">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7cb7f757-54a1-47a3-9040-75797ea23652"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51973ff6-5855-4de5-bd02-7375915f5a8f">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_233cb432-21fc-4034-9d4a-c938c1732433">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c85990c1-c9fa-49d9-9764-04cd7f6186f1">EV <link linkend="DCM_123007" xrefstyle="select: nopage">(123007, DCM, "Radiopharmaceutical Specific Activity")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5f06e3b3-536f-4938-8f0d-0dc67ed3259e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ca09f0eb-38d9-4d9c-9dd0-b97dd48569a4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72a09b87-1903-4de1-b8ca-6b4cb5077220"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10de3cfa-550f-46b2-a45f-e12d283ec405">UNITS = DT (Bq/mol, UCUM, "Bq/mol")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_945e170a-11e2-46ab-aba1-7f405251463e">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c21403c8-592f-4f47-8088-a32f049a9d84"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a2fbcc8-d5be-4b41-8ba7-0c52d5031065">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b93ec38-e0c4-4798-a246-e5ee82aea344">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f91f1c8-ab2d-4a7c-85ce-55fddae16935">EV <link xl:href="http://snomed.info/id/410675002" xl:show="new">(410675002, SCT, "Route of Administration")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb1a1c3a-e7e7-49c5-8703-b8ffe37247d9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d714ab82-c99f-4ef1-88ad-7177b7a1121b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f0f6466-d357-4fba-a7df-0088a37c6309"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_34f8403a-8a36-445b-ab06-66609688e5e8">B<xref linkend="sect_CID_11" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_15bb16fb-4a0b-48ad-825a-ed6efcd76f53">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e76beba-98f1-49bb-b453-26b1fb20e563"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27824a34-e2b6-421a-b3a1-b58bdfa1f3c1">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04e0a575-4c80-4736-af6b-a102642cd51a">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d05bcfad-bc87-408b-a124-b70d433004ef">EV <link linkend="DCM_123009" xrefstyle="select: nopage">(123009, DCM, "Radionuclide Syringe Counts")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d8970f02-48a4-431c-887a-930937014622">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_334094e1-fda8-4350-8259-c717597d3006">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5838c892-7415-40e5-9527-9e72e4abcf9e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_948b61d7-f837-4349-814d-82afee09b254">UNITS = DT ({counts}/s, UCUM, "counts/s")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4e179d8-34ae-480b-869d-b5795cde5c03">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd28c70d-b2f8-4e7b-a570-5add3e98375a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e000bcb-1f19-4bc2-b495-ef13a01c713d">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82640e9f-a2c3-48fe-9e10-311417507a1a">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5fb8076-0438-4c7b-a891-c3845e438b1a">EV <link linkend="DCM_123010" xrefstyle="select: nopage">(123010, DCM, "Radionuclide Residual Syringe Counts")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_66e77bb6-5bfa-4ae0-828b-fd2fd535d5cc">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f0c2b460-ddbc-47b8-98f4-61cb58be76db">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85503189-5820-4fad-8021-1943a6c8d5bd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c5dc25e-7f62-48a4-ae30-1f61312aa3a6">UNITS = DT ({counts}/s, UCUM, "counts/s")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9955823-0300-494b-bf38-3cb274f330d6">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae1b9db5-d681-4c75-917a-e93baa5e209c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93c45947-7926-41ad-8bf4-066c92a6a162">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_76378be5-8d85-4115-8092-c6a0479a2ae6">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_01ad7f78-088f-458f-a2f8-67962d0bbf40">EV <link linkend="DCM_126203" xrefstyle="select: nopage">(126203, DCM, "PET Radionuclide Incubation Time")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a1e0a84e-6fa6-41e5-9ee0-26d666e44581">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_980b6964-15d1-4918-914c-2abc5c5acf74">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_313007b5-9cca-4be0-b596-72366baf63ea"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f042955c-33dc-440a-8605-d83726d5ded8">UNITS = EV (min, UCUM, "min")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c9a20a40-ec20-4e6b-bf9b-5c6176c5514f">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b404b2c-d801-4f69-b455-16f0f9dbd54a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e804d2db-9d1e-4309-9216-de81fcb31a24">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5af5e3fb-0c95-4cee-b1a8-16a7c756caf7">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_66312693-4379-4070-9ff9-3c04daeb5a12">EV <link xl:href="http://loinc.org/14749-6/" xl:show="new">(14749-6, LN, "Glucose")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bcbd1765-80ac-4278-978f-2cfe687230ae">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_949ef4c7-2eb2-4a19-aa8f-fbb0f66f7e77">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d298ac23-9eff-4721-b83c-63fed328befa"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc8e3db1-b1cf-455e-8a72-fcc4e76fe918">UNITS = EV (mmol/l, UCUM, "mmol/l")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81660a3d-71eb-4a10-801d-c5f47c69adbc">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bef5afb8-0924-4ded-baf5-e180269a6e29"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4449c649-a81c-4827-a474-1cca3502f9c3">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02900285-f0fe-4322-9c29-6176dfc655a3">DATE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_928bb41c-26ab-4eea-b286-b06067786a98">EV <link linkend="DCM_127857" xrefstyle="select: nopage">(127857, DCM, "Glucose Measurement Date")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b409354c-e4a7-4fbf-b28e-36f18a46fabb">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6d1b344d-823a-4968-a7b5-dc6b8e405212">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5cad91c-f163-42f3-813e-1ae7748955bf">IF Row 13 Glucose is present and does not contain Observation DateTime (0040,A032).</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd7fa0e0-b227-4ade-912f-71151c345a2a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a91fe48-e3ab-4eb7-9afc-f65cf770ea79">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88afb275-1f21-4954-b689-fc7d7502f591"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df26e9f1-c588-4fe8-9f2c-49e933676ac4">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e1f91711-42f1-405a-a0c1-16e296baa980">TIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82e31834-6572-4f50-ab1e-32ec162fa094">EV <link linkend="DCM_127858" xrefstyle="select: nopage">(127858, DCM, "Glucose Measurement Time")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ada74815-033d-4587-8400-d7a13a11ca57">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bf7445c6-1349-49dd-b1c6-92759118cbb2">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_430f77da-3c96-4494-a09d-fd80ff0df524">IF Row 13 Glucose is present and does not contain Observation DateTime (0040,A032).</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_940f6c75-0581-4fd0-bdea-a7324c5f6731"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_25176600-ff6d-49a1-b369-6467fe348caf">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7afccc59-b74f-4bb5-852f-2587e2903ac2">Row 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_731e9af9-8f6c-4c30-b3a8-99f889c447b8">Half-life of radiopharmaceutical</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a8e97a0-ce2f-4e3b-8459-e46d748e92bd">The units for half life are chosen to be seconds, to match the units used for Radionuclide Half Life (0018,1075). See <olink targetdoc="PS3.3" targetptr="sect_C.8.9.2" xrefstyle="select: docname label quotedtitle"/>.</para>
                            </td>
                        </tr>
                        <tr>
                            <td>
                                <para xml:id="para_eb57bde4-94ae-4700-87db-512acb2db33f">Row 14</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_2e18d700-fa6c-4ed0-bdc2-ad535dcbc85e">Glucose Measurement Date</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_17f21b52-ec58-4b24-9e58-d365266c52e6">In an earlier edition of the Standard, an incorrect DCM code was used for this concept, which was already assigned as <link linkend="DCM_109081" xrefstyle="select: nopage">(109081, DCM, "Prospective gating")</link>.</para>
                            </td>
                        </tr>
                        <tr>
                            <td>
                                <para xml:id="para_086dea0b-ae17-4f90-8144-04c04b07f44e">Row 15</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_2d7163af-dc37-4918-9e0a-11cec393d6af">Glucose Measurement Time</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_d316c4c4-4fa2-4dd4-9418-5218704b320f">In an earlier edition of the Standard, an incorrect DCM code was used for this concept, which was already assigned as <link linkend="DCM_109082" xrefstyle="select: nopage">(109082, DCM, "Retrospective gating")</link>.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 1608" status="3" xml:id="sect_TID_1608">
                <title>Image Library Entry Descriptors for Prostate Multiparametric MR</title>
                <para xml:id="para_fc107bb0-0a66-46e9-a67f-eda2e55675cb">This Template includes attributes for image library entries that define the type of the sequence, as needed for PI-RADS interpretation of multiparametric MRI, specify most important sequence-specific attributes, and provide a location for reporting prostate imaging and sequence-specific technical characteristics of the acquisition.</para>
                <note>
                    <para xml:id="para_c019377c-9f6d-459a-834b-f5a976396c17">A descriptor specific to prostate MRI and PI-RADS is provided to record Prostate DCE temporal resolution. This term follows the conventions used in the PI-RADS guidelines.</para>
                </note>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_9afab555-fbc3-4c33-87fc-a5d648bc37d4">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_b20d2ecc-7db0-4b22-bdc4-019fc184ecf9">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_0284a6bd-c04f-4122-b344-03685d3f2952">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1608" rules="all" xml:id="table_TID__1608">
                    <caption>Image Library Entry Descriptors for Prostate Multiparametric MR</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a9d02e26-4d25-4d8f-851c-6e396f9c0376"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_63329f19-d4cc-4335-b308-506e868dfc53">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_850b76a2-60dc-437a-87d2-6a2f9a2b40ac">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_13c4d8cb-29ff-43f2-93bf-180b31978b1f">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_17932581-9ab3-4477-92a4-b1f8348c5324">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9ce9001f-153d-411c-9fb7-ad1d77419be2">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aeabd5d9-67f7-42b3-900f-16a0bc158c9f">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f8d1d0e3-cc29-47b8-a9dc-8b2d836ae161">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_18634857-018b-440a-992d-daaf6c89738c">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3640f935-505e-42ce-a9cd-08c6d350713c">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b44fa16c-853b-46eb-bcd0-8442a66b0014"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_650139a0-ce36-4629-9ac3-ad176dcf29b6">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ff62eac-b603-4450-8c9a-24ffe5d14cb0">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e48d56f-4216-4299-89c1-c99e6d7c78f1">EV <link linkend="DCM_130544" xrefstyle="select: nopage">(130544, DCM, "Endorectal coil type")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4af3c6f3-0179-4299-b0ba-08609f47a14a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_46b6cd5e-3cc7-47d0-a153-6a5f39eaa1c7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7dbc263-458c-4aa5-9dd3-c1effc88a7d4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc277240-9702-41c7-abdb-854dbf3ec7df">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_682cfe21-0ca7-4660-bee3-e1c784cd398e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_12ecf670-9221-427c-8c5f-e403da308615">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8851ad04-f7d7-44f4-a6eb-fffe218b8038">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_78790636-d1db-478b-976f-d8a72df51d50">EV <link linkend="DCM_130545" xrefstyle="select: nopage">(130545, DCM, "Inflatable endorectal coil fill substance")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2dab35c7-aad2-44a9-8cb1-fd698901d84b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b94c31e3-07ba-4dc5-b385-03868b475769">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a2807f5-7804-4f13-bfe7-e94eb1631473"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e893df2f-da9b-4c22-9bd2-77113346cbcf">D<xref linkend="sect_CID_6350" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_34695073-5c11-4838-b248-5b859d9e15ff">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ddd3fe24-cf0b-426e-8428-94f91d4b8102"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82b66347-ad12-4618-b9fa-ad84f57fd439">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8007d20-885a-4fc7-a1dc-976cf83b8ae1">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83c828d7-758a-47c5-8107-c8e484ecfadc">EV <link linkend="DCM_130547" xrefstyle="select: nopage">(130547, DCM, "Dynamic contrast-enhanced temporal resolution")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f6dc0e45-478c-4191-9825-7ad3ba1d8449">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_30836743-385d-48ac-bef4-040c473cffcf">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a50630f2-43d0-4634-8a12-632bd4f66de5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8edc432-b4f8-4647-894a-ec92ffae5065">UNITS = (s, UCUM, "second")</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 1700" status="3" xml:id="sect_TID_1700">
                <title>Generic Blood Lab Measurements</title>
                <para xml:id="para_5ea888f2-005b-4d6d-8c9d-4da386390c94">The Generic Blood Lab Measurements Template provides for the recording of measurements made on a blood sample that is not specific to a particular clinical application. The type and anatomic source of the blood is recorded as acquisition context. The results from the blood chemistry measurement system are quoted; the measurement names may be pre-coordinated with the type or source of the blood, or generic measurement names may be reported. In the latter case, the full measurement concept name may be effectively post-coordinated using the recorded acquisition context.</para>
                <table frame="box" label="TID 1700" rules="all" xml:id="table_TID_1700_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0e78e259-4e9b-4fb9-bfe2-8303e822929f">Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9e02bf0f-449c-4767-8cf5-a396a1ae09b7">Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7187cc41-23f5-44b5-ad9b-d494418648c3">$Measurement</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f4ab63c-fe3a-41e6-a623-f2f3bd83adfa">Measurement.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50280029-4f25-482b-a8bf-4150840fc1d9">$Units</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c537fa58-482c-4081-86a8-e332d8b3f6fc">Measurement units.</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4f84bf30-8145-4e5b-8cad-3a45b7fa32e8">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_41de4800-f338-434a-87b4-689d5d60fde7">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_7f35648a-2761-4c19-a02c-629693c834a4">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1700" rules="all" xml:id="table_TID_1700">
                    <caption>Generic Blood Lab Measurements</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4987f05a-5355-422b-8c33-7e514d577854"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e4f00950-4d02-4302-9252-afd242a08c41">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5e2f06ea-06cc-4955-92af-4429e9ee318f">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf5c943d-04e3-4e1d-bb3b-94cb43b206c3">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c1ff0434-4ba7-411c-8c05-04ff500b46bc">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5a97c8d1-e628-488d-a617-420b4908a9fd">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0baf045a-3fe8-4ce5-89e5-687528579066">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9a1ad789-c457-436f-8fe4-181d48ec05bb">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8bc24c7b-fa21-47e9-b44d-6290675e093e">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c3697b30-8a18-4729-8547-f6f667d3740e">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3c235f5-20e3-4af5-b627-ebef7ca9773e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_64c7d372-f369-442a-b005-6568b0fa3ba7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_66f13e7e-593a-4e37-a8a4-6b09e8a619be">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80c29f53-7b13-498e-9521-4a91bceb2203">EV <link linkend="DCM_122125" xrefstyle="select: nopage">(122125, DCM, "Blood lab measurements")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f9fabe1d-acac-4e2e-9255-69773087497e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_55125bc7-faba-466e-8ec1-a5380705e0a1">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_40c1eff8-100c-4978-9b6e-e777ac061ec2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0658fbe-57ab-41b1-bb69-70b3b944aa43"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8dea3cb-1028-4adb-bba6-cd9f9307daf1">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85603144-dc8f-423e-be3b-a4fc447cc307">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51cfb59a-2c16-40fe-9863-e559d831c775">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25ce152f-b0af-42ed-bdca-84d63211cca5">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cedf615e-6823-4a99-9736-4f2269291c75">EV <link linkend="DCM_111469" xrefstyle="select: nopage">(111469, DCM, "Sampling DateTime")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9b46de95-2f18-4b69-8abd-79c502b73f66">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_94c3b678-a711-4601-9f68-4e9e0d8aa66f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0c1b4e65-762b-4d63-9622-71afa5c98e1b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee421057-c02a-4ce1-83dd-e01565aa9823"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5aa941c-264c-4ecd-8dee-8ef1444015fb">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17893e99-39ea-4a4b-ac1e-f3e047927436">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2093feb3-05b4-4d9a-9d17-68ba9b0e97da">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29679bd2-5bd0-4b97-96c1-0ad351b4bbd3">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7404ea4f-2a79-4ac0-a961-2680824ce749">EV <link xl:href="http://snomed.info/id/371439000" xl:show="new">(371439000, SCT, "Specimen Type")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3f88d0e1-26b5-4f2b-af37-4bfda9e6a96f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_70d62a58-1122-4786-bedd-20f932fb8b42">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51716510-e0be-491c-b544-6e4f2629a4d2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb04834f-1086-4212-a664-2dfb081eaeb4">D<xref linkend="sect_CID_3520" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_721a1e51-02e7-4aa1-8da3-8dff07ed4746">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c6ff5c6-81cb-43ae-a772-b73e6c1734d1">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1f740694-1441-415e-b5d5-be446d1ebb98">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d69e714-d13a-4260-9ac8-221319c93558">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f93d2e9-8cc4-46ee-964a-1d26b3701814">EV <link xl:href="http://snomed.info/id/363704007" xl:show="new">(363704007, SCT, "Procedure site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cc4fa6ac-5a42-44d6-a281-16188aff251e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5d8d8fdd-d34b-4d48-8b14-d23d243a608b">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a989d147-93e9-41c0-a735-54d4a552f69a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7a4727a0-128d-4f62-af45-56f509bccb62">B<xref linkend="sect_CID_3630" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ddefeb30-c8bd-4e57-85a9-d76e9a758bdf">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d6395dd-8954-48c1-a8b7-f9bc1867ee87">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_66eb6f5f-0995-44e8-bb54-5067641b88c2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9877180e-2334-44ae-88af-5cc4aeead15e">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9abe3662-259a-441e-bdc9-a6bd9cc8045e">D<xref linkend="sect_TID_1000" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5fb2183c-856b-4931-b895-6d67cf0d2010">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_abc18110-70d2-4494-8088-42ba0480293e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1358d4f-bf55-4e88-b225-c7c03a59df1e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3082a49-9838-4e42-ab55-4808f9fc9c5a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f09e4ea3-3078-459a-8a68-94115ec63dbe">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1969978e-f495-4b94-9326-5271e314ad9d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4f4ffb2-cda4-4c82-83fa-1485b93decdc">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e60d597-345e-4b7f-8a57-731d8bd41ad6">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3fb236bb-518c-479e-911e-dea89be45e86">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_34cf0460-ca63-46af-b82d-6211a3e6924f">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4ee17671-1910-41ae-a27e-523d8a54103a">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1a82745-58d1-4272-986d-9669a9d97bcf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55fa530e-cdbc-4c17-a5e0-802ec6042561">$Measurement = $Measurement</para>
                                <para xml:id="para_4d799622-dffc-4e8d-bc9a-43087806936e">$Units = $Units</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 1701" status="3" xml:id="sect_TID_1701">
                <title>Imaging Study Quality</title>
                <para xml:id="para_6dd2af37-a132-4d39-add1-b825c3200e74">This template provides the mechanism to describe image quality both at the study and individual series level, following a specific quality control standard.</para>
                <table frame="box" label="TID 1701" rules="all" xml:id="table_TID_1701_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_94464c6f-dc1b-4d7a-9cb9-dad8997ec1af">Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ebfd95b9-5c2e-4936-a5c7-53cc9ce685b8">Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb21f655-1b39-4052-aa77-00d2e8dcdd53">$ImageQualityControlStandard</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab34f4ed-e665-43e7-8dd3-c696e46d9238">Value for Quality Control Standard.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1593ac6d-b1e7-4ed1-a7f0-40acc66a2775">$StudyQualityFindings</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85745edb-1ed9-4d50-9e38-07eb5385d7a9">Value for Study Quality Findings.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a90b6d7-7f1f-4259-b2b9-cb9c337bbf55">$SeriesQualityFindings</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d7164ec-c336-4ca2-8aac-e03430bb4f15">Value for Series Quality Findings.</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_748a6ca9-0e2b-4913-822f-6874343fa931">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_dd53d0a5-49d5-45f8-a8f3-1b96b23d4391">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_df590b72-39dd-4f51-a8ab-f60ea1bcab72">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 1701" rules="all" xml:id="table_TID__1701">
                    <caption>Imaging Study Quality</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_188a224e-6779-4cfb-bc57-e409e5603a38"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_057aedf5-0d08-44a7-88d9-b83d9c28b073">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3902e759-7917-491f-aa5d-691f98da1f10">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_058d1c94-6e2e-4731-9248-f3681bc0e8dd">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_687690e1-84d9-43e2-a8b5-046f1e67fe97">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d5ae6878-1d64-4992-b357-ec1ccd82cfd4">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_935874d7-e62b-46a7-9a22-d6c71ff7cd0a">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_08c90695-ab44-48c7-8a8c-7191bee6ab60">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0b4c2f2d-fef2-4afd-8845-69386f3d7a24">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87ba7bb1-d2cf-4db6-93f4-f11056dfcd9d">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c03dae1-3703-4f5d-b2d0-8153c5c1a103"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f527466-9860-43b0-b879-ab321d9db357"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4760f2c2-824f-48cf-989d-ae9a8aace42b">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_89b98e67-f212-462f-8642-40ab32b8b9f8">EV <link linkend="DCM_130549" xrefstyle="select: nopage">(130549, DCM, "Imaging Study Quality")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9fe2d666-8cff-480b-8beb-3819951575e0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d80be90a-1e73-4c26-aa49-15e206c84e46">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_756a4c44-360b-469b-96bd-e52e0394894d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2d02f2a-edea-44b6-ad2c-990242fc467f">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a1f41c1f-94e2-4873-92de-fc2db0295339">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb6b097b-e581-4e4a-b1da-c35eb8d66e00">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88a89cb5-0965-4b5e-ad14-52423445a061">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e952b29f-82f6-418a-8bac-5450c1df2f39">EV <link linkend="DCM_111050" xrefstyle="select: nopage">(111050, DCM, "Quality Assessment")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f737bfd-4f5b-4a8e-836f-d775e6431cc5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_934a4756-5713-45af-ac57-464ee72029a8">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25560498-be36-4a34-a3dc-794ade3519be"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e276f9ec-0302-4970-86c9-e18512fac46a">D<xref linkend="sect_CID_6044" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af81f7b6-d829-4f6e-bd64-8895f22e7e9b">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27d67e09-71b5-4b67-9c54-652a49f1e99a">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_082f19b4-bdc2-40f0-90be-e9fbd47e9158">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce490939-d55b-4add-8cee-1d4aa5088e6f">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c10a6a1-5a95-4933-8a8d-b13bfa857dd2">EV <link linkend="DCM_111051" xrefstyle="select: nopage">(111051, DCM, "Quality Control Standard")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2fd6372d-e584-42b2-ba54-fec0db3cbaaf">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_284d24ff-3447-4a72-b3b7-e1799025d36e">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54cf8d65-42db-476c-a6ab-9f5dcf9342d4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_68c3eab0-ce80-4eeb-a0b5-ffcfe2e19255">$ImageQualityControlStandard</para>
                                <para xml:id="para_44d7ff0d-8bfb-4712-9a6b-bc4fa06cfd87">Defaults to B<xref linkend="sect_CID_6326" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_417c1712-7c85-4115-b07f-ff1b0507f09b">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_297d0fe4-6509-4e13-9033-2e45096ccdf6">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_407e635f-e9f0-48d6-8684-0195afab3fd2">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a9441d2-5f6c-4677-b0f8-3b01e97639be">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd56d607-dc67-4cbb-ae2b-caa4e9715e20">EV <link linkend="DCM_111052" xrefstyle="select: nopage">(111052, DCM, "Quality Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e1545d05-f355-4680-b557-e7d3bdf174c0">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eee40f79-6181-4bd6-8d48-83f787b5f748">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0c2509f0-c1be-4f00-b0d8-7f6a85bd857f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ed8ba71-3117-41ba-8635-26d1dfce27a5">$StudyQualityFindings</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1e46169-7dd3-4ae1-a615-f7d7a74a35d8">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_649ddb70-2383-4e9f-bf98-dc560780e5ad">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_77b84863-f487-40ae-9498-1c28faf51b44">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7fc8ac2b-15ff-49a0-9626-328345d963a7">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf255f49-9775-43f0-9b04-cfd7464fda58">EV <link linkend="DCM_130550" xrefstyle="select: nopage">(130550, DCM, "Imaging Series Quality")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_201cb4f5-50f0-42bc-afbd-7aa63a822533">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7bd40380-ee5a-4965-8715-9389e8757462">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_49e28f50-3b8e-4095-b183-c75b8f7c1fb2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_038cfd28-2874-4d62-815c-92089c3675a6">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd253ee2-ce34-4daf-80d2-1285434cf64e">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ab8e8e3-fde1-4d08-bf66-e810e646f5ed">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c39a55ce-e246-4df6-947e-9555d84c1466">UIDREF</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1f002b59-3ffa-4013-a074-1c4cb37938ad">EV <link linkend="DCM_112002" xrefstyle="select: nopage">(112002, DCM, "Series Instance UID")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_51a4daa3-ced8-4320-bccc-e9ffc8613b45">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1067c100-863f-457a-9e84-49970f615533">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f087f4f-8949-4423-b63b-7be55debdee3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58f42366-a3a6-4687-ba55-a9b62bbe70e9"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f476d12d-b3da-4e6c-9f18-e14eae629d86">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92600a18-559d-41b0-9b1e-65801358fcb4">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48a494ac-10d4-4345-8601-e053ac44430b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc2cd54d-8700-4900-b17f-f34f4cb1f95a">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1726a9c2-d93a-49d8-80d0-e5ceb0f27e83">EV <link linkend="DCM_111050" xrefstyle="select: nopage">(111050, DCM, "Quality Assessment")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b7a3ba99-887f-4c29-a927-69346e095079">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b209a640-2a56-4528-a0b5-c90a4937e004">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb644d9c-624d-47c6-8804-c65bb3f89932">At least one of Rows 7, 9, 10 shall be present</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e32f15fb-a236-4520-b143-5524b80e1330">D<xref linkend="sect_CID_6044" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa439d31-c3f1-4669-a62b-73f6b8a8a2a5">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3921ad6-e3d7-4492-96d2-78ba1dab158a">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_963ebdd9-93fd-4816-8da7-b1b2b4b88d12">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_309c1c38-0cbc-4e47-b5aa-6ffb120237fe">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00b5628e-41d1-4061-8541-3b0e42b929bd">EV <link linkend="DCM_111051" xrefstyle="select: nopage">(111051, DCM, "Quality Control Standard")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a59a1ad7-d6c8-4504-be93-961360815d2e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_be30da61-e1d1-487d-a793-4f477759942e">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a5748b5-8a36-4c12-91f0-42ba30a63a0c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8c9ff13-54a6-4828-8abf-52ca13810a44">$ImageQualityControlStandard</para>
                                <para xml:id="para_5ff35445-33ae-4262-9952-57fc13c0bb57">Defaults to B<xref linkend="sect_CID_6326" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c3edbcb-3681-4467-94c8-3feb15059a6b">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54cf3cd0-8766-4306-b8df-d59cbe95688a">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00972ac0-a7ae-43cd-8e67-31c1c56f52ee">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a97e1a59-3ea7-46df-bb6e-bb37e09f92da">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0ee52a4-b4ad-4267-8838-77cff022ab6f">EV <link linkend="DCM_111052" xrefstyle="select: nopage">(111052, DCM, "Quality Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_349cebc5-cc74-4904-9e38-6c3194e599b7">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d470a0e2-8ea3-4641-b0a5-5008bc49764f">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10ebfbb1-0738-4119-9cd8-eea8d0b7331e">At least one of Rows 7, 9, 10 shall be present</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1da86aa3-a22f-4464-ab64-2e87188f24e5">$SeriesQualityFindings</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3587382-972a-4062-9a59-b644a0f18121">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_64dfdc31-f009-4a5a-8615-4d1c50abaf1e">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b717e62-f71f-4523-95ed-ddd28c71bdd0">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97f86561-662a-435c-8761-3d2f40aa5383">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c957d6c8-7e9b-4acf-8707-b47c50129aaa">EV <link linkend="DCM_111029" xrefstyle="select: nopage">(111029, DCM, "Image Quality Rating")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ba601aef-0333-4873-be88-32fc617957ad">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_77362de2-970b-429b-b549-e6628418fe2b">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed61ecda-4fd7-4908-af8d-0b5fd5231bed">At least one of Rows 7, 9, 10 shall be present</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_951de549-3571-45ad-a049-cca58e76d524">UNITS = EV (%, UCUM, "Percent")</para>
                                <para xml:id="para_6ad41358-f5cd-4b7c-85ef-696ba6947714">Value = 0 - 100</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_bdc40cff-b25e-4286-960a-765c21b80a3a">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a81d1d0-58e3-4b6a-8f22-5bd4cbdf4692">Row 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c46e6aae-b471-4ab6-aa15-695647ae8636">Defines the series to which the assessments apply.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
        </section>
        <section label="Diagnostic Imaging Report Templates" status="2" xml:id="sect_DiagnosticImagingReportTemplates">
            <title/>
            <section label="TID 2000" status="3" xml:id="sect_TID_2000">
                <title>Basic Diagnostic Imaging Report</title>
                <para xml:id="para_69241d4f-fe25-484d-a1ee-e67ee2494d6b">Basic report Template for general diagnostic imaging interpretation reports.</para>
                <para xml:id="para_eb159548-dfc3-43e0-b384-8abece09223c">Can only be instantiated at the root node and cannot be included in other Templates.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4ecc5d1d-c868-47f8-bd4a-494c1c70c97c">
                                <emphasis role="bold">Non-Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_be65ea30-c386-4866-831d-08e3441a37f4">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_0462a00c-d705-4573-99ec-1e206bdc510c">
                                <emphasis role="bold">Yes</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 2000" rules="all" xml:id="table_TID_2000">
                    <caption>Basic Diagnostic Imaging Report</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_97f008fe-9987-4ce2-b139-32b48c69c861"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6b1f54c8-ea91-4c58-aa78-5cefc38189c4">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e650b853-8900-45b3-80ca-1f25a57d805b">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_448c9c5a-248e-42e4-bdfa-70a6ab6a6067">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_57b0ed18-2847-421d-b94f-1294d35bd62f">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85f60694-14a0-451a-b66c-7d9f1538f6db">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a9f4f574-66a9-43b7-89a4-37883ae69766">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e59cf6ee-2af0-4cbe-8550-e7514897158a">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_efd98bb3-86f5-42d8-9780-faad20880c87">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cfef6f10-5479-47ed-9618-32a48b212299">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25656471-98ce-4870-bc98-f941d9a9ba46"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46c21dfd-0518-47a2-b6ec-da590efe5d0f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b8233f3-a905-46fc-aa27-e593f67c69b5">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac517288-790e-43ff-bbcb-2fdfdc370ba6">B<xref linkend="sect_CID_7000" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4c247dc5-219a-407f-a1a7-c2e2ebd50a63">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_efa17dbe-034a-424d-b76e-925838e0acee">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d8c1300-8cad-4f49-9515-f1e602ed2f4e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_60eb87e7-d476-40c9-ad80-8383383df7cf"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86a47e3d-3fe0-47e2-a15c-51176992e41d">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0480d822-9aa7-4bd1-9c7f-69bb90f79bc8">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a55fdb27-466b-40e5-a947-4a3c48f2ff03">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d4330d7-7845-457e-a9d9-6280fc531cca">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce1d7711-463e-480c-ba77-709a93744a4e">EV <link linkend="DCM_121058" xrefstyle="select: nopage">(121058, DCM, "Procedure reported")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_29fa6f41-e9d5-40c3-aa18-c2c302056d6a">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b801e428-53d9-4141-a604-4875915f9780">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0aca4fb4-770a-4ebf-83a9-42a0d2612cec"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_64b77654-7a70-4ea0-a2eb-21e34cd70818"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_18c55cad-71bf-4555-b984-86678e8c13c7">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a75f7013-84a2-4624-9df8-662db0f24dd5">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa578232-a3fd-41c3-aa53-ba800f38c017">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f176b784-3e8c-46b4-9022-0dc93f6632d5">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f50e74b-2711-416e-80ad-dfe07e266f2e">EV <link linkend="DCM_122142" xrefstyle="select: nopage">(122142, DCM, "Acquisition Device Type")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b52f1bf5-fd93-49fa-8bb3-26c35e89fd87">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2065595c-3783-4e43-ab18-976f439284dd">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72c5cb8c-8e81-4848-ab91-cc39ea100d84">D<xref linkend="sect_CID_29" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86cb82bc-427b-48c9-8f6e-9037a73c153a">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ae56bdd-cc23-4dad-9411-75de169df863">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d38a5f41-f865-4444-a403-ef20016f4718">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b9a4a21a-aeb5-4cff-ad36-2dbc0e52389a">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4f30346-6963-45fe-9cbf-1d06e2cbf647">EV <link linkend="DCM_123014" xrefstyle="select: nopage">(123014, DCM, "Target Region")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5a2dfda5-fd08-49b5-832b-ed96a4c2f925">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_db7ad8c2-8720-4b0b-b057-9cfbd25adcfd">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13fafd98-0824-4a4a-81d4-ad3787a250a5">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00bfc3ff-59ab-45b4-9847-15d25f326c00">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0baa724c-dfc2-4343-a87b-b8d648156687">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba59ee9d-2414-4d33-87c8-e5e12491089c">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98b64d38-b8e3-4045-8134-0dd3e35479a0">D<xref linkend="sect_TID_1204" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f7450ffb-9d93-4e10-b152-5d181aa00e37">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4e814f7d-a33c-4fd5-b0c4-7c6d6f26378b">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b0027b3-0ea9-402a-880a-7a4fcea231bb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0addeaa6-e75d-4577-9ee6-d5722ca057f4"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_047f33c8-6db2-46c5-b431-4bdc97e32178">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1726d9c6-f0a5-4f60-b4c6-72600ec63e26">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36c9dd50-ec18-430a-af55-297aabcda218">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e751772-8301-4a30-85c1-f541cd4aac1e">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7eb57b3b-c898-47bd-8016-0e2f96557098">D<xref linkend="sect_TID_1210" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_803bbf36-e40d-4f87-ad1d-03b491b4640c">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73c765ba-fdbd-4795-b18a-2b72d4b56a04">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6009fc84-697e-42dd-b81b-7763abd483d8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8bd8e3d6-ede7-44f0-b442-25d200511f2f"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a230b843-264b-4b01-841b-a0007ee32b4e">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b140789-b432-4ae9-af8f-a841f2bb0b13">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_28e0592b-f087-443b-b10c-d0fc61df2fcc">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22e38e88-f0e1-4241-93bb-e261643fc9b1">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24448d00-e45e-4e8d-8852-167cd7b20230">D<xref linkend="sect_TID_1001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_04210074-9a92-4b65-a28f-b0a0c362f200">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f657bc48-2119-4204-b8f4-ab95017d2ae0">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e354928d-8d74-4836-9ce8-fb2f436af15c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e573007e-18d1-4602-9bea-7fee37fd03b6"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e1b606e-64f3-419f-8ced-4b260f416c96">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0924d71c-3f37-4d8f-8551-f7a455ffc06b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50e9dac2-000c-4189-ae45-a9181fc26f24">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f204373d-6c65-432b-9b04-b9bcdbb336ab">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65235835-dbe5-4456-b9ba-1761e45cb182">B<xref linkend="sect_CID_7001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b2bae565-8c6e-4071-adfd-1dd9a5ca10a7">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d9dcb870-2162-4967-a393-c7bc38821bc4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02e2b384-4fd8-47fe-babf-877fabe68f1a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ecfa50f1-670d-4c5f-86c3-0e13f675c08e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2bf0b3f7-24be-4e75-9377-1f425e0db815">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_632f2200-1d68-40d0-8a85-7eff1a19749b">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ca2e522-a316-497f-a88a-24325018f9e7">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b4ec524-b698-4066-a96a-36c0bedddf36">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af82d032-184b-4fc3-acdb-18ab1b9514cb">D<xref linkend="sect_TID_1001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9e669ae0-c635-423d-9e65-f4e2036047ae">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e3cc469f-db1a-44b6-a8bc-4b33d3dd4468">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2d5788bf-e492-4930-bcbc-7ed1d2d15636"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59c05870-ede5-47e9-aa42-81adb623dc7c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27c331fe-bd2e-4100-8789-73eeb3315273">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8506aecf-2211-4895-8e16-ed8bb248a84a">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc6744c0-80f3-4bcd-aec5-df111b31d5e0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ffce23d6-b43f-496e-8457-bf08945f8567">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_753c3f21-3992-4025-9556-62d4da46b9f0">D<xref linkend="sect_TID_2002" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_12fd2c50-c451-40ba-9c57-b7678768b962">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8bbd2c14-e2f5-4d03-9ebd-00acc2e63c47">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3c92ca2-c0dc-48ca-a49c-eaef08694a26"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80b3455c-6af8-4a18-aba4-1fd2cb5beae7"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_1392b7d4-8800-44c1-8c71-0f1d8e89b412">No Content Items other than those defined in Observation Context <xref linkend="sect_TID_1001" xrefstyle="select: labelnumber quotedtitle nopage"/> may be the target of a HAS OBS CONTEXT relationship when <xref linkend="sect_TID_2000" xrefstyle="select: labelnumber quotedtitle nopage"/> is invoked.</para>
                <para xml:id="para_5928c147-96ae-4e52-a2ff-085de2bc5094">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_01fb39e0-dc4e-465f-9e5d-af1ab0ac5d41">Rows 2, 3, 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03915aa1-bab7-49d6-ab39-ee7a25de0ccf">The content of Rows 2, 3, and 4 shall not be inconsistent with the meaning of the report title of Row 1. If the report title does not include the concepts of the procedure type, modality, or target site (e.g., the generic "Diagnostic Imaging Report"), these rows may provide post-coordination of those concepts. If the report title does include such concepts (e.g., "CT Head Report"), they may be encoded duplicatively to support report categorization and search.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 2001" status="3" xml:id="sect_TID_2001">
                <title>Basic Diagnostic Imaging Report Observations</title>
                <para xml:id="para_9d8c1fc7-cecc-48be-a0ed-4b4e978c8202">Individual numeric or image observations that may be useful for inclusion as individual findings or as the source of inferences in a report.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_48d6d379-ed5e-4637-b824-729f8f20ab8d">
                                <emphasis role="bold">Non-Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_d392bbd9-24dd-403e-879a-8a4c14be8ec8">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_8a5ec18e-b5ec-455f-b09a-f5afc8912289">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 2001" rules="all" xml:id="table_TID_2001">
                    <caption>Basic Diagnostic Imaging Report Observations</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f3419ff4-e3dd-435e-b979-cbf4b228d3e1"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fa362791-40c8-4d47-a246-5c0b2827c414">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4f1723f4-4a43-4a04-a17b-d4534a8135cc">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3805cd14-37d8-4e74-a0b0-1046dc596d8d">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e25a0690-b819-466e-a8fc-af7d4be21f76">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_378f9c1d-240a-4166-98df-e99f2ff8a7cc">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e5854c23-8164-47c0-ab12-cc7598f0e7c8">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1f38c4ad-bcdb-422b-8cd0-385a31724ca0">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_743e6bcf-ecd8-48a4-888a-a06507bb9962">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_db3c96c8-9c16-4374-b80e-dd899f2010d5">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4357606b-2268-465b-8a6a-b9b7dde426c2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_95c34743-0117-4487-83f1-95164c611283"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f92bf8e4-e629-4282-9aee-3687e2c1bf52">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d2ec9733-7723-4d95-b124-473d956c9e76">B<xref linkend="sect_CID_7003" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_663f83ba-3850-401d-9121-23d3bff94f3f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_acfe2a4f-3e40-4a89-a002-aa33b7f52019">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_378097f2-fe8a-4561-b0c5-7024b9ed504c">XOR Rows 2, 3, 4, 5.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e16ce838-ce0b-42b9-9c70-ef988a238294"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91e77ab0-6807-4fe1-b4d4-d266e88f0261">2</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b8cbe002-4ca6-4474-ab0e-905d92f048af"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_14e3b3bb-51a6-473c-bdba-d0ef8c25dad3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4c4a74a-e643-461d-99a4-8f04b3bf6a01">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b9c66a3-f891-4fb0-9865-fdb95a31fb93">D<xref linkend="sect_TID_1400" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c952dee-0ef6-4f22-bc04-412b0215bf48">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7a4f7fe8-828d-42cd-8e5a-1bca5ce8aabe">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46366d73-5853-4b2e-8166-7032a54861f1">XOR Rows 1, 3, 4, 5.</para>
                                <para xml:id="para_24ca4ae3-c654-439b-a850-30d63992cf94">Shall not be present if the NUM value type is not supported by the IOD.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31a54153-4426-4ed4-9db6-39c3cff9d658"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_114e4240-bc0c-441f-b5a2-e74d44016936">3</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d37b1789-44be-4f70-bd96-bf62df8a7506"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c96435b6-027f-491c-b20e-1c1f53d7b0ee"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_465ac87c-6552-4a81-ae06-ffe1ba04ed63">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8417b5b1-636c-4d4a-9ae5-ae105b79488b">D<xref linkend="sect_TID_1401" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_02956d45-f694-4d59-b629-f6042538f012">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7d30997e-933d-44e6-9a5c-dfe1fee0d466">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_888c2ac3-5066-4295-ba74-b54b621d6e2e">XOR Rows 1, 2, 4, 5.</para>
                                <para xml:id="para_a6c13a8f-e966-4ec5-b162-083fdbee47f8">Shall not be present if the NUM value type is not supported by the IOD.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce7b9d86-0252-4e7e-b951-74f805394f61"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_44afbb39-3ca2-4d7c-bd03-a6de74b2db4c">4</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1366a8ed-cdeb-4402-b772-0d32f69c9012"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c1977bba-bcaf-47c4-964c-bc57af6841dc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6619aa49-941a-4944-b368-cf211ea8bc4d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_380d5d3a-2259-44db-b06c-8c6cde0aa2cd">D<xref linkend="sect_TID_1402" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2583e810-efaf-4cbf-aff1-5867a5e30c5a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8efb57a6-8566-471e-b80f-d36fbd572172">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b905403-b667-4973-ac37-cd7d492e62f1">XOR Rows 1, 2, 3, 5.</para>
                                <para xml:id="para_f63896f1-d32a-4a8d-8ce8-e40e6384438d">Shall not be present if the NUM value type is not supported by the IOD.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d9cc2b0-b564-451a-8b6e-b7f4de419748"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe13cd6d-2e75-4fe9-9982-fc53b5fb14a9">5</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b7be7ad-a8da-4951-8d23-a8629dddd420"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_81aea18d-720c-40d9-affd-a586838d47af"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ab2343d-dbd5-4e11-a331-3ff0269ddf5d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef4d366e-c042-4b01-a138-27d0bc0100ff">D<xref linkend="sect_TID_1404" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0c82f4cb-cf85-4fbf-a84c-e1fda9ebd325">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_be8eb5f6-ff9f-4110-b6ff-faaa7ceb0d35">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04b939b7-05b0-4ada-9dae-f251a95d3506">XOR Rows 1, 2, 3, 4.</para>
                                <para xml:id="para_f50d2e84-b95d-4db0-9b9a-2a654a125bf9">Shall not be present if the NUM value type is not supported by the IOD.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_14781565-bdaf-4fe5-8f20-d76de53b1cda"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 2002" status="3" xml:id="sect_TID_2002">
                <title>Report Narrative</title>
                <para xml:id="para_e1c63091-1f76-4835-b7ec-140c068fd1a1">The Report Narrative allows recording of text, code, and numeric observations. The order of Content Items in the Template is not significant; the order of Content Items in a SOP Instance may be significant to the narrative flow of the report.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ea4eb955-1751-46c7-9d2c-9809a69e0412">
                                <emphasis role="bold">Non-Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_9f0047eb-ab9f-4b8e-a2a6-e923180e1670">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4ccdf563-b14a-4784-96e1-40cc0d3fd0c4">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 2002" rules="all" xml:id="table_TID_2002">
                    <caption>Report Narrative</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d9048ddf-5e4a-4629-8cb4-92dd60289faf"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8fa9498c-cba9-478c-9d90-651a300e7d2b">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ce11e87e-99d5-432e-99eb-c309058cd0f9">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf109fa0-2c0b-4505-941b-20fe673b2118">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2aee39b9-84f9-4a72-a73a-d9f4a7361a72">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_68424f2c-a98a-4c35-8bf8-2527f86ee7da">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7d61400f-1914-4aa2-af22-9a2b74b63a69">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ee69ad1f-964b-4b87-9efc-5bf53098e722">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0904bf89-3dc8-4e6e-95d5-1ccb15bc891c">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4263b3d-407a-4de9-b49c-6ce6266427dc">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b80dbd82-6c5a-4076-8860-a376b5744b55"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6349c9cb-909c-462b-aa76-c14527d5266a">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e379a96-5e5e-46aa-9641-924a0a5254c9">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6880e86f-5c99-4804-bd4b-9950b3ed6a51">B<xref linkend="sect_CID_7002" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ba1a4f4e-3d18-4f78-85c1-62497da56fe6">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d25058f7-7374-4089-94a1-cca18c181b53">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0f486c4-d790-4f3c-a55f-d1a71c70f7a1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42a0175a-bbce-4670-a9a5-c43fb1c4effd"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7287a91-f97d-4ec8-88da-8d5c93d15e01">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c15118d-c407-4132-84cc-f814e1a46b18">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_333b50d6-923b-4719-b01d-1138e495f0f4">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_abb6fc1d-7e48-4664-8e6b-6910a41a6ef6">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de335305-d117-42bd-af4b-27c03b3a96f6">D<xref linkend="sect_TID_2001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b1624e87-c331-4799-b472-9183f9153467">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_425ef7c6-2e79-47e9-987b-b3b5619d7c58">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_839a49ca-2600-432f-a0a6-c4431389956e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af34b6ec-b9a1-4af9-a7b2-434a5df6aab7"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c87be71a-d74e-4803-9af5-52b645f42bf0">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73185245-0b8e-41e5-ad09-2194f76bb368"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c2f3884-d934-4e22-8b2f-19dd14917676">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d21ba3c-58ea-4b09-a805-9b8e56c65f3b">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_789d9697-e34c-4527-9306-b18f4a4dae2d">B<xref linkend="sect_CID_7002" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3c6b220c-bb25-40e6-bbef-cdd0009b1d8c">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f89391a8-4f72-4514-a07e-7e39919c5f63">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_934ea377-7935-4189-a7a6-7072dbf4d1e1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f7aed997-9a42-45f0-9491-70b789a3977b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_45948b84-5742-4131-b254-038c0e32890c">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9ad26d0-aa3f-49ac-828f-dbbf919dddce">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99348ee9-c560-4631-8afd-6f15aa6e9bd7">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17666c5d-4c3d-4ee3-a32f-70df07e9caa0">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fefc16f1-3563-4ecb-a9ee-f74b4425ca6b">D<xref linkend="sect_TID_2001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8aed4284-05d4-4efa-8d99-bd996abec1e0">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e8a6e4b3-991c-4905-9800-36253a3472d1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d00d29f9-224d-4449-a19e-3922cfbfb390"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2ed1855-e0d9-40c6-96e9-d3f109e0bb44"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e73149f-bd28-4c04-a018-0e4ac64f26ae">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_327c43da-009b-4b0c-8808-1306e1fa1df4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4cf5f1fb-0ff5-4715-97e9-d6fab37b06bb">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_01c3fedc-6336-489e-8ec0-70416df1928e">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5807bac0-01f9-4a35-9744-0d85989d43af">D<xref linkend="sect_TID_2001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d9062932-b6f5-4f3b-a764-4eac9d62c7c1">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5838a470-3abc-4e9b-8f9e-e256777bb54b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4361f4c2-9461-445e-a538-db2cc684b9f5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e2c30c8-a571-47db-8c1b-cc000e0dca9f"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 2005" status="3" xml:id="sect_TID_2005">
                <title>Transcribed Diagnostic Imaging Report</title>
                <para xml:id="para_a34d4f80-3441-4014-8c17-2ce2c074f8a2">Basic report Template for general diagnostic imaging interpretation reports produced in a dictation/transcription workflow. SR documents encoded using this Template are intended to be transformable to HL7 Clinical Document Architecture format (see <olink targetdoc="PS3.17" targetptr="sect_X.3" xrefstyle="select: docname label quotedtitle"/> and Annexes in <olink targetdoc="PS3.20" targetptr="PS3.20" xrefstyle="select: labelnumber"/>).</para>
                <para xml:id="para_4e03b152-fb6d-4268-bd6e-6c93b555853b">This Template can be instantiated only at the root node, and cannot be included in other Templates.</para>
                <para xml:id="para_98e7f156-6565-4a94-a086-dd5956d93bc7">Observation Context shall be inherited from outside the Structured Report Content Tree, and shall not be changed within the Content Tree. To satisfy the requirement that Observer Context is inherited, either or both the Author Observer Sequence (0040,A078) or the Verifying Observer Sequence (0040,A073) from the <olink targetdoc="PS3.3" targetptr="sect_C.17.2" xrefstyle="select: title"/> must be present in the SOP Instance.</para>
                <note>
                    <para xml:id="para_ce326aaf-74d2-498f-8649-95e971394ee8">See <olink targetdoc="PS3.3" targetptr="sect_C.17.5" xrefstyle="select: docname label quotedtitle"/>.</para>
                </note>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_b57ba0ad-6504-41fb-abcf-e5a411fcbd81">
                                <emphasis role="bold">Non-Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_0bd133ed-accf-45ff-a184-1ccc0cfbe390">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_3d7ec330-144c-450c-870a-9fc3f9d59188">
                                <emphasis role="bold">Yes</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 2005" rules="all" xml:id="table_TID_2005">
                    <caption>Transcribed Diagnostic Imaging Report</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5c0d5737-2906-4e86-98a8-cc1455860a62"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1035a669-fc88-4353-a784-48a09713deb0">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c34a6c5-b375-411c-8f40-70188c351080">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_11d5ce02-1c35-4b3c-8401-2dedf1a37b0c">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0662b9db-227a-47a7-8f0c-4ad5f4f85379">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_129577f9-9c2a-480c-91d4-bf66699b72f2">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f935f48d-8a04-48c0-8102-d8e570bab829">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0cad8cad-5cac-4c1f-9281-84a36c961a13">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4baeaeab-ceaf-4954-9eb0-612854bb23fc">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2dbd556c-4871-4540-9916-63151c4b4d21">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1800f7e7-e9a7-4358-b780-3dba321d2e09"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f840d958-3038-4a05-a8e8-a227fa44cc59"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7ce30ee-9074-455b-81d7-be1bde6c43d5">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79f04c43-6dd2-4376-8b23-aa647419b5e0">B<xref linkend="sect_CID_7000" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7dbc9454-5366-4776-96ed-9ba6b0cc8857">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_326fcafd-64b9-42d2-a6fe-6f3db1698138">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf0e73f5-6928-4a5d-96ea-1a1a8b19098c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e012f77-5b3c-4cdc-ae68-1783f19cf8e6"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e0f7b327-ba40-42e8-955d-d8dad18af02a">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d412671-c810-4235-9ef3-11203fdba5a2">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_536e88ee-03f6-4a01-b3ab-8167f7aad6c6">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_378c9408-6fec-47a9-9fbf-9d9c433238a0">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d4af997-3bf7-4e87-80d9-399779419508">EV <link linkend="DCM_121058" xrefstyle="select: nopage">(121058, DCM, "Procedure reported")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_298b0da5-aeb7-46ed-b3ce-03060c7ae13f">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6dee5714-d6c9-4844-908a-2d6b458cfc0b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74d4bf3b-1ecb-436a-a84b-ca1b49928585"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29935080-b434-4e6b-b0d7-72c55eb319e2"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42a1172e-90da-4680-a40a-b19a485db14d">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_374432d4-ff2d-432b-9207-0c6279b6ff6e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a6254e6-3d63-4c51-b05c-535a8a49420b">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d4d02d3-855e-4f84-87d4-b36c10d0f8ab">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5aafdcca-c8e4-491a-9cd0-96423b6bb691">EV <link linkend="DCM_122142" xrefstyle="select: nopage">(122142, DCM, "Acquisition Device Type")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0386eb0e-5417-49a5-9e5e-47a9cd405db5">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6d85dfe0-bab3-4f1f-85de-f4fb18ea9bb1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8acea25-44f8-49e1-bfa0-0bb9df4f13ca">D<xref linkend="sect_CID_29" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4db18e0-ef43-4d88-ad49-17a6a75767ef">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d41a367c-a546-465e-a15a-660c47575755">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4249e323-ee2a-407f-8d7d-c39d53750949">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_efb8b335-dd9a-4727-b487-67a30effaf6d">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67226a14-de46-48e3-9125-e3fd83414ec4">EV <link linkend="DCM_123014" xrefstyle="select: nopage">(123014, DCM, "Target Region")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9a5f3eb8-4c64-4e4d-be43-a97a78bfd478">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_413bf1cf-267d-4832-b2e5-0b745091c2f9">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4dbae6e1-f6f7-4c4c-9287-f431aef068a1">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9ed1e7c-6de7-40df-ba70-01fc2b6f2a06">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f86bb57-2714-40c4-b968-6ac9f06b1b21">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06b80a7c-3bbd-40b5-99d3-5cb3ebc689da">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6e7e3b6-56cb-498c-8c3a-88f98f6bfa9e">EV <link linkend="DCM_121049" xrefstyle="select: nopage">(121049, DCM, "Language of Content Item and Descendants")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3e96a674-aef0-44b0-b8a2-7b7cf517bd40">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b9a001e-d6a3-4837-a6f8-481987113a59">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a00da96a-b531-4333-aee7-295ad33dcb56"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_208677cc-6365-47bf-a94b-d6b64507c748">D<xref linkend="sect_CID_5000" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10d02b54-09b0-4870-9da4-70d2c147d789">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1a74616-dadb-4566-bb27-627e97a4a83f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bbf051db-3123-4143-bbef-e8c58f57ed6b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3eb54a8b-5812-41fb-8cc9-f9597ad58e01">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85d30ed1-f2bb-4c10-b889-df309bf9f431">B<xref linkend="sect_CID_7001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cce40cd6-77a6-4e00-8f8d-043be6029955">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc6b9617-6b3a-4e6e-9c79-4148554bf799">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9df0016e-a522-434f-ae15-bbe62a635a06"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0021d412-fde2-46bb-89a6-023a946467fa"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ec3c8a9-ba38-4d70-992d-2feb56fd41d0">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1eee1719-906b-4798-915e-5e0b576d145b">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87f0b11c-84ff-4c6e-a218-e6cd386778c2">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c2b08604-dc67-4fc3-abd7-4e45410abda6">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74734d80-6f67-43bd-a070-8afa89641df3">B<xref linkend="sect_CID_7002" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_66163cc7-4bc5-4e78-a827-89c2bbd129c9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_590c9e57-e67f-4885-a0ac-48256397a55f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c44ca77f-86d9-47fe-a063-75b12dda27ed"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_12975c98-f652-4ccf-96ca-03490aac7301"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec3edc5c-cfd7-420b-8a14-50d553b55d66">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30a6378b-3de1-416f-a308-73037758b2bc">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a87ceb30-981f-471d-bc3e-705bbd82896e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8302ae9-3df2-4a57-9153-4e5aa6b4d45a">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da818623-3a5d-441c-93cf-5d61a576654a">EV <link xl:href="http://loinc.org/55113-5/" xl:show="new">(55113-5, LN, "Key Images")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1c6f2447-1f09-4b23-9bce-97bb1f51f5dd">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a5ed21cd-d71e-4936-8ff8-6b7ef996b8f9">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_07dafef3-185e-4dda-805e-d278b7ffaf00"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_781e6296-a92a-4ff1-bc99-e484dfa8e483"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_582ce9c3-b337-4e8c-9558-7b176720c156">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70abe312-429d-46ad-a40e-9c3da12e1146">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_743bbf9c-468c-49b2-a89e-ea0ffe039dc3">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea7eb6fa-7083-424a-88b5-3094360e589e">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed597685-e770-416f-a9f1-6df65c986698">EV <link linkend="DCM_113012" xrefstyle="select: nopage">(113012, DCM, "Key Object Description")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a0a2ef9d-9e5e-4fca-b848-fdd1b586a0f3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e5793edf-f9fa-44b9-bcb0-5d88b321d1db">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b9e3930-5cb4-468a-97ba-760c996a99b9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6838994-f305-495a-83de-2e25aebb473e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52a7462c-4c39-4b90-8cdc-cc5d6aa02c48">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ef0f541-9a89-4a2e-a099-9358a3a578e5">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_faf319d3-689f-4cdd-81f0-cc1b02450be0">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_932344ab-d9e8-4e04-b64f-8e9e90e88590">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_77e503fb-34b1-405d-81dd-95d2b8693162"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8da7f68b-ec91-48a0-9995-959c6117e52b">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fbb0a19c-6c28-45b1-a902-9c799de3b181">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63d5a1ba-0c4e-4004-838a-f987eac2200f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5d0fc38-2600-4321-ba5f-87b10e51aca1"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_9d31b7cf-fa5a-4aff-81a3-c309f2cb7a5e">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7089c4d0-9d5e-448b-9eb6-497b795bacc9">Rows 2, 3, 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5abbe42-b142-4134-8c08-ae01110d91b6">The content of Rows 2, 3, and 4 shall not be inconsistent with the meaning of the report title of Row 1. If the report title does not include the concepts of the procedure type, modality, or target site (e.g., the generic "Diagnostic Imaging Report"), these rows may provide post-coordination of those concepts. If the report title does include such concepts (e.g., "CT Head Report"), they may be encoded duplicatively to support report categorization and search.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_064d676d-9539-4971-a72e-ff34aab1799f">Row 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cfc95aa9-8a62-43a6-ad50-62e70f41423a">CONTAINER Concept Name may be absent.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_783a7855-18fa-4e92-a55c-d33394fb2160">Row 10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4241d0f0-20b4-422d-abfe-49fc538e1c84">IMAGE Concept Name shall be absent. Purpose of reference is not specified.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 2006" status="3" xml:id="sect_TID_2006">
                <title>Imaging Report With Conditional Radiation Exposure and Protection Information</title>
                <para xml:id="para_de9b9061-67dd-4979-8d9c-35d6beec328c">This Template is used for general imaging reports for both radiation producing and non-radiation producing modalities.</para>
                <para xml:id="para_c5d8e220-d107-4e16-9852-c058982ef866">For radiation producing modalities, radiation exposure and protection information is required, such as to support nationally-specific legal or standard requirements.</para>
                <para xml:id="para_b48dff9f-0ed0-42bc-9e17-cdbe85cafbe6">It contains mandatory sections, each of which may appear only once in objects instantiated from the Template, including the medical content of the report that comprises relevant medical history data, information on the current request (i.e., clinical question that is expected to be answered by the requested procedure), impressions on the current imaging procedure that has been performed, and radiation exposure and protection information.</para>
                <para xml:id="para_9af4db1d-8ee2-4b6a-ad4f-b8b464f96871">This Template is a specialization of <xref linkend="sect_TID_2000" xrefstyle="select: labelnumber quotedtitle nopage"/>, in that it uses the same structure of headings and content, but mandates the presence and order of specific headings, and extends the subordinate content with specific Content Items.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_d4bf6f1f-4859-4aa4-a1d7-8c9bec1dd0ea">
                                <emphasis role="bold">Non-Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_fcfdd85f-4b26-4e2e-90f8-dfff447343cd">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_231d23dc-b0e2-4407-8279-dfff94e5077f">
                                <emphasis role="bold">Yes</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 2006" rules="all" xml:id="table_TID_2006">
                    <caption>Imaging Report With Conditional Radiation Exposure and Protection Information</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb27e4f6-7b36-49b8-a828-f1a03f6a83a1"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_774e6331-0a61-423e-a5ed-bcd43a123e0d">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b7275e8a-674b-4bcb-adaf-c9046d672224">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eb915f25-adea-43df-a9cc-8d3c365dba5d">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1bd407bf-f42f-429e-b3c3-32246bc6699a">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bd820588-41b6-4482-93c7-9f474e5df2cd">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b54cf76c-7d70-4978-af47-0c1c651a904f">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e706ab26-774a-427a-a00f-403753d836d1">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e3d39f22-46ef-4fa7-93e9-941f457fe249">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d7d12b8-e4fc-4970-8226-ec26f43d541f">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4846a32f-6cd8-41ed-9386-a12ce8a902bc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a3d0e53-4184-4c08-965a-e4a96e6bbfa6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a39d6cf-7e52-4521-8ffa-abd14de8da1f">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e9d6df1-3101-450e-8501-53d4fb35e916">B<xref linkend="sect_CID_7000" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4b91d587-1a10-4758-a5c3-08604b259e61">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2bf3af7e-53cb-416e-902b-13c9640912a3">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7683158e-18e4-4d4c-b651-16c9ab2c50e9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de5d84d8-d922-4e76-97ba-c0b73d7d1f50"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c57f000-9e83-4c3c-9c44-1a284c4f8cf6">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35fc5542-24c8-4147-baa5-3effea8dbf04">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff9961d9-63fc-48df-b400-f64b4a03e969">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab2259e7-228a-4f44-98a4-cb56d4c5c62f">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3153b524-7f47-42c0-ac7f-dce024b08cf3">EV <link linkend="DCM_121058" xrefstyle="select: nopage">(121058, DCM, "Procedure reported")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_390185df-6800-4798-80cc-4fe535e9da01">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b91626cd-c1e6-488a-8a72-7e103f8a1182">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50897bed-5ff6-4be0-8596-4a6e65cacb57"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1935a632-3924-4848-86dc-a1f5098eebc7"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e7b3670-502e-4efc-ba8c-71079df7c5ff">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a939cab7-7276-4e2c-a66c-b8c7e32fa445">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f5bac50-486f-4157-9019-9693ad349306">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d482ccc-1b9c-4e99-a823-5fb4ab303820">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8533f4fc-9035-4219-b171-499321ea747d">D<xref linkend="sect_TID_1204" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b023ed94-6c5e-4027-8c5c-f2d3ca7b37a7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2313246b-bf0f-49d5-baf4-bba326329a44">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b9ff892d-4613-41aa-8efc-29808925069c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_007cab27-0f48-4e68-ba1f-15524bf92fa9"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e60cfa8-d760-4e58-afd3-4284b4f19c55">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a13f2676-96d7-4fcf-933d-ef6751489b30">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f7e27f06-ac85-4ac0-a423-c1859f4988e9">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ea11b4d-654e-4f65-aee0-5cae2714e8ae">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5508530a-0ac2-4b29-b3ae-2e7920c11b03">D<xref linkend="sect_TID_1210" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8348c91d-613d-4dec-b93e-d69f7bf063f1">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c97e39ea-7155-4d59-95ae-f831f6e40d0d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5071508-c766-45fc-b510-98d3a34bf43c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8f4826f-5b8e-4f0b-9ef6-ac9888eb7afe"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8990e2cb-615d-4574-bed6-bda82477a46e">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83c8cafa-1d4a-4269-aec0-c3b9b4c4b07b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4d12421-9ffa-46d2-ad25-9ace902bdcdb">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9266ebca-8ae2-48d0-bb57-beee9c6052e0">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d92f5252-69ff-467c-995d-ee8c68bc584d">D<xref linkend="sect_TID_1001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3295a68f-1c1b-4583-972a-9f37b7ad8072">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b07b2dd7-4b9c-43b2-861a-e4195324b1b6">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2b2f281-1c63-4fcd-b369-f66165e08fa0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c5f60b2-fc29-4bfd-ab8a-90f71bbf3378"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9b533d7-8a8a-434f-97b5-3e981bc5f1fd">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c319e6b-2d3f-410b-96e6-ad3716f512f3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f56f1bbb-5db8-4d7f-87cb-81baa52f8590">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d64f6d67-ac13-4f3b-bd4e-b503feb45fca">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16f8772e-e20d-47ba-afcc-4fa80eeed1b8">EV <link xl:href="http://loinc.org/55111-9/" xl:show="new">(55111-9, LN, "Current Procedure Descriptions")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ddc36524-dd41-4293-abe9-423f70d0f7e0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_91451347-a159-495b-a107-dcf72b8c29db">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87e4ed50-40c0-437f-98a1-5cb9097906bf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7dbfd553-2602-4c85-b9c9-57702d62456e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3e34f05-9241-434d-8ebd-d957a51cd929">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08577e48-e434-4009-838e-70491aab2db2">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf37ed6e-72f7-474a-aa97-173fce7ec184"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7be3f549-90a8-4388-b3b3-b26065d0bf31">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d229c91-5011-48ce-a0ec-05f05f078268">D<xref linkend="sect_TID_2007" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9bcf94da-258a-444d-b677-f6c2578c88a9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_87d33ea5-47a5-4338-a15c-2936a26eb572">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_593feee4-ba91-41d0-987d-9244274c1b5f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff826337-52f1-486a-bba4-3544c6c06909"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_64b383d6-af06-40b0-a7ed-93644672b317">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85f78e50-a4b0-4ecd-b353-6c99ab17a5b7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b908077a-4060-4bcc-a85a-fcf38eaeb842">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b69e9356-c3f6-4682-9d26-2589201912b0">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2e12d48-d6db-4cef-b664-ea3a364ac414">EV <link xl:href="http://loinc.org/55114-3/" xl:show="new">(55114-3, LN, "Prior Procedure Descriptions")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e9de5a97-8041-4532-8a65-50c54b1747c9">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fe0892ea-1215-4f9c-84e2-828661a09185">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c676341-b7fc-4b36-8459-13dcf191f5cb">IF relevant prior procedures have been performed.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f704cea-fade-4686-b20f-e0f457db51fc"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_528c4064-4769-47f9-a4f0-af833d758cfa">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d353e09-891f-4260-a689-11498f7bedb3">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1adb2a17-8b83-4fa5-bbaa-ad86a9acffb9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1cce8c90-8db0-43bc-b6b0-04d8897ac3d2">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a1d22e5-21cd-41ff-9dea-86881264e513">D<xref linkend="sect_TID_2007" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3dd4cbef-8b4e-4b6d-835f-14c9b53c38e2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7970ef73-e438-404b-b8d1-6e6eeb89d60f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd1593b9-df4e-4831-a20b-cf431713a7fd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c10a01cf-9ba2-4ed3-b3e0-b44e212c16b9"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_631eb14c-d293-4e2c-833c-6ccc42bf4662">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa47df60-a579-4f3c-8df3-06488f32b4ef">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b9d8abb9-227a-48fd-bd33-212a88dbc8b5">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ed60c5b-4d21-41eb-b3b3-71c1a74b9887">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1efdb7b6-f2f4-400d-af3a-e3de4df57b95">EV <link xl:href="http://loinc.org/11329-0/" xl:show="new">(11329-0, LN, "History")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_95547420-68ca-4482-ae5e-713d36023e51">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_abe139b6-f1ca-4668-ba1d-42a2c99ada70">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a9bc8fe-e718-4dda-9214-5c981c1b90d3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ab50112-02e9-4b25-a73a-67ffe887e62c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_154140ea-3ee6-4985-9824-06466ecb356f">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0117d33-443f-409f-94b1-288ebfc1fbac">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_14cbdd04-cf5c-431d-8f0d-c002c391e1f2">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e2cfd8d-abe8-4152-ab2c-5639514812f7">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6307a13-8785-4e12-b55b-6677cb316b74">D<xref linkend="sect_TID_1001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_390a0cca-1bc3-463f-bdd6-9f2e28b027d6">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_89bab22e-05f3-4bc6-91ec-2563aafb09c3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2d5895f-619d-4d1c-8ccf-201b4914d070"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c71edd31-4c98-440f-a6af-aa2d7e118b17"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_266ad92e-2b6e-42fe-8ce1-6d3bf74bfe25">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bbb75af3-4c5f-47d9-8d2b-9024e9b1321e">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc733f11-0304-491a-847c-7532621bc627"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_894db879-9967-46cb-8ff8-ebfbef9a5be0">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9813acbb-1f3d-4072-aa47-4cb72f5edb20">D<xref linkend="sect_TID_2002" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f9ba5f7-38e6-4361-a56c-704c939e89c7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9e2b6296-0d5c-4afc-ba8d-d893f53bc8fd">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f57a32f3-6b56-40d3-8f40-157e7ed7ee59"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03b83391-9839-4b4d-8518-d41a2de70a69"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cfe004d5-b350-46ca-aff9-31007f69b1e2">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a236eac2-09bb-4fca-95cd-33b8791b5612">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5d0d256-1844-45b1-83a4-759307758594">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ddf5cfaf-88de-432e-8991-c37d94f8ebd1">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb98fa4a-7020-4985-ad5d-e2ce4baab52c">EV <link xl:href="http://loinc.org/55115-0/" xl:show="new">(55115-0, LN, "Request")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7f7b4aaf-3f0c-4806-9690-90fc273ffc2b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bbcf24c2-b025-4181-b5b8-8e8662b4e900">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57a578cc-5770-4619-91ca-fce4345eabb9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79086bde-a8b6-44ba-b5da-9bf3000b8fc7"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06b180be-5663-4347-afad-94030127b9bc">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d2cb18a-f669-413e-8e74-770493e8fcc1">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_90c52e43-8256-477f-af2f-dc47f3df8d12">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fec37f12-555b-4586-9b65-2b6ba479a86c">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0cf29e9-0762-4203-89f3-4dbd7e17cc64">D<xref linkend="sect_TID_1001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cb107f54-0881-421d-bbf6-32b433ae356a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_263ae359-e4c5-4a2b-bc93-eb1eab7ee871">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e7aa44e-a758-4ac4-b57f-554fa4bbf6ff"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e139683-c66c-42b4-8158-e9d63c0dc660"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a097477-2b2e-44a2-8b8f-8f954ee9c353">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_936acd40-8179-4b90-9529-9e36abf2cfc8">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e531f06-99af-4eee-b3ab-c2dfef08e372"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa47d710-5017-48b1-8280-dcdd994a75c2">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5f29926-80d3-4501-92d6-f564e7c96a49">D<xref linkend="sect_TID_2002" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2c924f02-3b74-4e45-b7da-8b2d62c811c3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c5a7d4df-2b0f-4062-8e86-ef19deac950b">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86c0e4e7-98e9-4e28-893c-bb40e31cb907"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f2eff0d-c3bc-41d9-8be7-e8a14f627d5a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d01387e0-fa05-42d6-91f7-2003fe1c6f5d">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a9b1dff-dcbd-41c0-8776-c4cbc091ebdf">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88e2191d-d27c-43ba-ab91-48db18c72760">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f49e671a-9dff-49f3-93d5-7d1f5b9db781">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_129385fc-9c2d-4728-a273-85a2a57ce6ef">EV <link xl:href="http://loinc.org/19005-8/" xl:show="new">(19005-8, LN, "Impressions")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6a1c0987-a115-430f-a71b-4f66d8e7ddfb">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ccf2f0bb-a1be-4125-983f-c0c43cb08241">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9fcd074f-d9ae-4268-af95-fab1eb66d564"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_db35eaba-2843-4027-825a-1c8e69719f76"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5dc3c789-a2c6-4a12-b975-f1defc0802a8">17</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ddfbf9c-abea-4427-aef2-49bee6961051">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_41d39761-8242-4df4-abc0-c65cf6e1599b">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_705b5a30-0425-4ac2-9e00-925a72a24651">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2224554f-62d5-49d8-8f9a-32f35ad7bdcf">D<xref linkend="sect_TID_1001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ccd5a601-bb60-4855-9179-04a58e7d1e6c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a230b304-4e57-4d58-b424-ab85f2e07c14">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10c545d1-622e-4723-b992-f646f32c5abc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_925ea482-1efe-4df3-a59e-9a7d5ebfdefc"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52fa1df7-b724-498a-8c2b-3f521dbe8be4">18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8eec8a03-968f-4034-a575-341e1a026567">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4c2bd89-5aa3-447b-a7b5-d36abdc6a4d4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93dc73fc-631b-425c-877f-324a23fc07b3">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8225f50b-a1fe-4a92-b08d-67cdf03374d3">D<xref linkend="sect_TID_2002" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_178f6c18-ff16-4da4-86d2-83843f172baf">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9893f217-3ff6-4a79-a81d-4d8d0d31a487">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f7166594-061d-4f40-8100-bc7c899f3621"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5aeb55dc-fbd4-4b75-8656-e675a9c74832"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d64f889-f251-4dbb-881a-bd371bb571cb">19</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54c0ffdc-fae7-4517-bce4-1cccad8ebac0">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ad59e6d-c788-46fe-a11a-d4a9593b8de8">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d06d3ad-61f0-48ad-90a5-acb3e87f5dd6">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38a7d1d9-cb5a-4a68-a442-102d037c5706">D<xref linkend="sect_TID_2008" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_44578fb0-501f-4a58-96fd-b99d724c74dd">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_506f9b7c-3bd8-4f71-a67d-0dc9bfaf3293">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1779ab9f-257e-48fb-b614-17ebbc816230">IF the current procedure exposes the patient to ionizing radiation.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a3c63b9-b045-41ea-92bc-34acb520e407"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb503791-263d-4567-a4a8-de656c5f37e8">20</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a3c10c4-2ccd-4848-ae08-d945f926757f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9ddf852-9d47-42e7-a429-0916d65732bf">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65246033-4e9d-48fb-9abc-6dcd0c7ef669">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_32cba5d8-ea26-4956-8289-16617cebaaa8">B<xref linkend="sect_CID_7001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a6438c57-1688-466d-ac2b-df24f5956239">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_166334b9-680d-471e-836c-fcc57edc0ed3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ba93c4f-b877-4035-847d-933475f06a58"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d005489d-697c-404c-ac47-48da9e0fd3bf"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bbe634f2-7704-448c-a237-85f6e1f8e623">21</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5879cee6-4f99-4bd7-920a-2478ec2c8882">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd466949-5e76-4e12-a58a-7a1ba83f292e">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82160d95-7b0c-4c92-a93f-e4c0931b7c05">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5958ec4-8480-4dfa-b681-2a11d914d628">D<xref linkend="sect_TID_1001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fdfe8b6b-c3ac-4a41-8eda-1065d8d162e1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9080feca-e41b-4dcb-8077-b06094c81365">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c025c1e-3c6e-48fd-b514-3120cedb80f5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9fbd0f78-58df-4d3f-a868-5b8ec41fcaaf"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4725c179-3cc8-4b85-9b3f-f70640f744fd">22</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ee48d3b-7f62-43d4-807b-2c4abbf152bc">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92197430-a11e-4a88-b26e-26f1873ab57d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58895ba5-b57a-4db6-a73b-f47c0320b756">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e51adc0-6e5f-4d45-8b6c-b2becdde394a">D<xref linkend="sect_TID_2002" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f0f41c8e-a2da-4ebf-b2b7-f35902ac8f83">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d1e8401e-f9ab-4f4e-94b9-7dd108ec300a">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_14d3661e-e4a0-4847-8cd9-ebd908fb6a06"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7dc83203-df8c-4e14-ba0c-59dd49b63972"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_97f0f477-d55b-4aab-8aba-99a4a4d2a82d">No Content Items other than those defined in <xref linkend="sect_TID_1001" xrefstyle="select: labelnumber quotedtitle nopage"/> may be the target of a HAS OBS CONTEXT relationship when <xref linkend="sect_TID_2006" xrefstyle="select: labelnumber quotedtitle nopage"/> is invoked.</para>
                <para xml:id="para_2bf17770-5628-4617-b4b3-b321d15a32d7">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57d07dc6-141b-4d45-b8cf-8467494d1fc8">Row 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b57eb502-3d60-455d-90b3-e13b9ff5453f">Even though this information is related to the content of Row 6 in <xref linkend="sect_TID_2007" xrefstyle="select: labelnumber quotedtitle nopage"/>, it is present here for consistency with other report Templates.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ff3b826-91b9-47d2-bdf9-1391a07ecdd6">Rows 5, 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6485c77e-7971-4633-8c34-042bd7f0e6da">Information on at least one of the following person observers is mandatory:</para>
                                <para xml:id="para_c7732e40-4152-4359-b1ed-58c99b5baafe">1) "Performing Physician"</para>
                                <para xml:id="para_f26fbe9e-33e0-4033-aba8-d6ab62938157">2) "Performing Technologist".</para>
                                <para xml:id="para_a91f0baa-45aa-48d9-bd1c-8c7031e94380">(For those person observers, requirement types as specified in <xref linkend="sect_TID_1003" xrefstyle="select: labelnumber quotedtitle nopage"/> apply. That means that "Person Observer Name" is the only mandatory Content Item).</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b591ddc4-6373-4e46-b6da-5204ff70f098">Row 20</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b55d44c-4fa6-42a6-84c1-6b83840e0ce4">Each heading (concept code from <xref linkend="sect_CID_7001" xrefstyle="select: labelnumber quotedtitle nopage"/>) may appear only once, and may not repeat the headings (concept codes) used when instantiating any other rows of this Template.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 2007" status="3" xml:id="sect_TID_2007">
                <title>Imaging Procedure Description</title>
                <para xml:id="para_a1cd05b8-3ab8-4c25-965d-4be45eb831ea">Contains information related to the procedure.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f934bd36-fe31-4ba7-8fae-8ee7c2e43da4">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_2a1a3ce4-84e4-4202-806a-30802ff943ae">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_c9e5039c-ded1-40e2-b210-65916f403053">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 2007" rules="all" xml:id="table_TID_2007">
                    <caption>Imaging Procedure Description</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2aec2d1c-535d-4d26-bdea-d34bb76c8813"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ebdce1fe-e7cd-4c7a-80da-80afbad281a1">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_91808fcc-f6f1-4787-8ed5-0887f1d16b62">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a6e86956-2d97-4866-a603-528896b2c013">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e9cc8252-493e-45eb-9d47-9b91bce861c0">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_93f7dde9-d4ed-440e-b20e-28e5348b3cc8">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cd126000-cea9-4e67-b87a-7cd60cb79533">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_795444ec-af3a-4d77-bed8-1442e4fa93bb">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8956f577-c7fb-4db1-9609-543f293cd6d7">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21a84eab-1215-4d00-ba72-94f189edb0f6">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_271e03f3-dba6-45bb-aa64-77734365128a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1498fed6-6378-4791-98b1-ccaf75056f44">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3578ecf-e37c-4828-ba70-f4b8e6b37f2d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d55d3e3c-cb9e-4ee6-9fa4-2656873c452c">D<xref linkend="sect_TID_1001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_714f583b-ef6b-4b0e-a864-5586abb9d838">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7a9509e5-69c9-400e-9c06-3e20b637efb1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d20d165f-be2f-4fda-990d-c1c307d04e4c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c9866efe-8e9f-4790-84ad-3cf1ed224c5b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8905b86-ce1d-44a5-a93e-e7b1c11bea12">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_737fae37-1dd2-4952-823c-17c4e4cdae3b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86d936eb-3aad-4acf-8cf6-966738c99794">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf21dfe9-297a-4afb-b24f-7c011624a753">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bbac1bf1-9638-4f77-b5f3-2fe19db6da37">EV <link linkend="DCM_123014" xrefstyle="select: nopage">(123014, DCM, "Target Region")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_654e05e4-d8c0-493e-81e4-616147539dec">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2a2de7bc-17c8-454b-afa5-e6845f04e8d5">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69ce55e1-8fb4-4521-abee-8cd3521090cc">XOR with Row 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b69d6c0-0108-49e5-a4be-7cbda409401a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_45592d15-47d8-4fc4-a98f-3f9f533ed2f6">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eebf67cd-43e5-47cc-92d3-7c65e18a935c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce5860ad-e1ec-49a2-b674-df34e03ddaab">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce9789bc-d5b7-47b0-bb06-488df27f1498">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8ed9859-ff2b-4121-b75f-8a4c63cfee65">EV <link linkend="DCM_123014" xrefstyle="select: nopage">(123014, DCM, "Target Region")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_95ed101b-b389-4d90-a672-4068ee739755">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_561564e1-8950-4425-b28b-cfe4e2de05d8">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65b5390e-8d68-48c0-94f3-5d07b6c83e03">XOR with Row 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6965f867-ebdb-4ce6-b5f0-0d7cfb089fcb">D<xref linkend="sect_CID_4028" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_d543068b-3488-40e5-9bdf-a700de948227">D<xref linkend="sect_CID_4030" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_86d1f113-760b-4e7c-bbfe-01803a48ecea">D<xref linkend="sect_CID_4031" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b8911fb-945a-4f58-a4fd-9dcdc0a99859">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1645adf-3955-4b33-b6c3-db30b68a681a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_082911dd-d2c0-4258-bd04-d0c9b930ef10">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_658e072c-4cd4-41bf-b605-6c697d1c91c8">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d54e0101-e8cc-4d1a-aa8c-aa1b186c8b9d">EV <link linkend="DCM_122142" xrefstyle="select: nopage">(122142, DCM, "Acquisition Device Type")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7153db25-a605-4e9b-b73c-a4f6efc4b4cb">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cc6abd83-5eab-4a38-8c86-b0cfb3046a8d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ef639dc-bc83-446d-a36d-141a71a592e1">D<xref linkend="sect_CID_29" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c68a833a-5bf5-48b2-b858-816874dfdb28">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e1e9520-70ea-4205-bbed-61490469d840"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73a81dac-f4be-4f50-8cec-e9f55e07deb6">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16dfa824-4053-4284-9f44-8606c49de395">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f70bb27-a7ae-4b12-b79d-3eabded2275d">EV <link linkend="DCM_121065" xrefstyle="select: nopage">(121065, DCM, "Procedure Description")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d34b2e90-569e-4c2b-9159-5dc8d09ee579">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_420d5724-74c8-4f82-a92f-b311ef7fc0e8">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96245632-3b39-48f7-85f5-8bcb5a2e296c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73f05c54-2b03-4bed-83b9-9e8761b86f7f"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea9a8f46-75ee-4ed0-82d4-18a82b8e1911">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0bed0c5b-1997-484a-a56a-011a12686136"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_76416e4b-9b3d-4b0f-83b7-1d7b1a45d2f8">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_838520ed-6155-46a5-8b69-332a3f7c980b">DATE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_175b1e97-d8ed-45df-aaa3-df299c2e314c">EV <link linkend="DCM_111060" xrefstyle="select: nopage">(111060, DCM, "Study Date")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c4a82c41-bd41-4136-8cac-e181ea37df2f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d94ae87f-e3bd-4191-bd49-405a09ead8cf">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_567182b0-eff5-4738-abad-c0f8f954efdf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf7ab3bd-6441-4052-b1a8-ca83713a8cb8">Shall be equal to the Study Date (0020,0020) in the <olink targetdoc="PS3.3" targetptr="sect_C.7.2.1" xrefstyle="select: title"/> in the images to which this report applies.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03612513-1a7a-4a2e-bada-0ba8023b3808">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1f69362-f7d4-4ac4-9f4e-d137e3619049"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_893f83af-a44c-4b63-b155-b55b0f1538f2">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c69ede69-2610-4ef7-a8eb-f449e7b9976c">TIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2653043f-31a3-429f-92bb-a2ca9ca4657a">EV <link linkend="DCM_111061" xrefstyle="select: nopage">(111061, DCM, "Study Time")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_42d5663f-663c-4518-8c41-9d04ed16ceb5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ae741991-c926-4ccd-bc9e-d142c8c3ceef">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51df870f-d884-4747-bfb0-d12fe45c7f64"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0667d1ea-017d-48db-ad8d-466ec2179475">If present, shall be equal to the Study Time (0020,0030) in the <olink targetdoc="PS3.3" targetptr="sect_C.7.2.1" xrefstyle="select: title"/> in the images to which this report applies.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_919be53d-c55b-4f46-9c19-41f27b7de306">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4635d070-abc3-4234-be00-38ebebcce9de"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_096da6f4-f663-4f50-831c-1bdd44c16b74">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96ada17a-85a1-4c87-b9a3-dd29bfab4fa0">COMPOSITE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_584b1f70-e632-433a-8c53-2b74917ad17d">EV <link linkend="DCM_113701" xrefstyle="select: nopage">(113701, DCM, "X-Ray Radiation Dose Report")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ce9cb113-cfc4-4282-92d2-b43c44f6101d">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7db6dc6b-43c4-471c-851c-ff52d4b25d6a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a37b21bd-4c06-4949-8376-bb525511a14b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f8ed69d-bb8b-4561-9100-6613d7d9c617"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 2008" status="3" xml:id="sect_TID_2008">
                <title>Radiation Exposure and Protection Information</title>
                <para xml:id="para_3b49f7df-3184-45aa-83b0-33f9cbedd49a">Contains information related to the radiation exposure and protection of the patient, as is required by national legal requirements or standards.</para>
                <para xml:id="para_3f295b2a-9fd3-42b4-8d24-4d7f2d6ce58f">Other information about the current procedure is described in <xref linkend="sect_TID_2006" xrefstyle="select: labelnumber quotedtitle nopage"/> and not repeated here.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f594599e-e024-4131-855a-4425227fa02f">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4b7ad78a-54f6-4e19-a4f7-a2747099ab5d">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4145f787-92a0-4767-8059-0c92b40a1efe">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 2008" rules="all" xml:id="table_TID_2008">
                    <caption>Radiation Exposure and Protection Information</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a51d66a7-a3eb-441b-92df-d83b543fb799"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_51018687-9d80-4154-9349-54fe978e724a">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7d4e4d0c-5a55-4018-a7aa-9e3cbb43b012">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8ff67d2f-00f0-4698-ada8-909a9348e6cc">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1c177b27-dfb0-4bef-9f25-e2d14b26a941">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ea2b4d59-034e-4b6f-b122-ca3826e34da2">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4be6eef6-449b-43d1-87bc-1d9fe721c859">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bbb2ca51-0cf6-49a7-9a10-426a46f76ac2">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a0fe39e5-3bc6-4477-a922-c997c2c24b56">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39c557c0-145e-4bdd-b917-6b77eb1a0d4b">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c679f211-816c-4f75-8b48-9a3c7fa6d253"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a6e1f0d-aa2f-47a0-97bf-ad64b00efed0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_755d780d-5334-4eee-85d0-6c93032a6fda">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a7162e9-b140-4b88-bdfd-1f7c7fb33113">EV <link xl:href="http://loinc.org/73569-6/" xl:show="new">(73569-6, LN, "Radiation Exposure and Protection Information")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f04a0156-2de1-454c-ae4c-2ecf104d5a74">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_51a2de0e-bb1b-4b71-8b36-65382ba71a70">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_897ef09e-dbe9-4d87-8b0b-212a540d9f4c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e92d7b09-8f58-425c-9f79-88fc637e73e9"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da3390f1-56b2-47e0-b35f-a9fd6a95f1f9">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a1de3166-4e8d-425f-9e57-3bec4d610014">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b88cdaf3-87c6-4ecf-a59c-5278420e5c4e">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab2647d9-6303-4585-91f0-4c8e3d64c362">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eedf354f-5819-4508-ae5e-75f9d8b7e784">D<xref linkend="sect_TID_1001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aeb63034-2914-4074-9fac-fc59c9147795">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0c9a5b5a-c720-48c6-99f8-ab753888f1d3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5620d8b-5c12-4329-8077-5c651b4bc23a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4018342f-81c3-421a-93cd-566c17040023"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d7a95ab3-9eab-4e05-ba55-cc2d403860a6">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e60f9ec-8437-430a-95d8-e1a5329670ab">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9eeafdd7-2bff-4ff9-9629-43340e874d6b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29a32e40-1588-4bb3-a8ec-aa0d9521a9ae">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_33189185-6577-4a24-ae23-75eae28979f6">EV (364320009, SCT, "Pregnancy observable") </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c3ff0e01-d104-4a01-a089-9c47bffd5a01">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_454f2bf2-6e7e-4394-a2e0-20ef925e2a3a">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_167fb1c6-cf69-4ebf-91e9-49f41435ddc8">IF female patient of child-bearing age</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f3482b8-bdb9-481e-bce3-fb5e61720dc6">D<xref linkend="sect_CID_6096" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7bdf4092-d6fc-41c7-9ffe-d7c54da745f8">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d6ee786-fe95-40c0-ad79-219383ac16aa">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2134c554-7348-479b-bfd4-a105ea12ce2f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3349c07f-2133-48a3-8cb0-60c528cab787">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a8a46a4-e295-4db9-b3ce-c40a1e897b62">EV <link xl:href="http://loinc.org/18785-6/" xl:show="new">(18785-6, LN, "Indications for Procedure")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1adae1bf-0367-410b-a04b-891a0b865d6e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c85a4aa3-2371-4f81-b7de-45bf81ffea55">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d22a353f-5a8d-4be6-998a-5a1a74a987b1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ffaa1d1-e00d-4b1f-bdb6-4563bb50eb65"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91d14cbf-1cb8-4c28-99e9-3b06dafa0116">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_806de5c1-6ae3-4cd0-8f9b-96ea46038fac">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58818042-e07f-44f3-ac7b-91e2fc182a24">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e1700cb5-193e-4d63-aa23-184b30e110bc">PNAME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e4392e0-49d0-4b74-8c75-0649bf80843f">EV <link linkend="DCM_113850" xrefstyle="select: nopage">(113850, DCM, "Irradiation Authorizing")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_056b7435-9093-44e1-a8d8-a83c968567a7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b521cdd4-e4ba-4e74-b941-936555d4f526">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_33a252f8-6d59-4b3f-998e-45ea93c1f86d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9b48694-4031-4024-b5cd-be56fb380a24"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11142f5e-02ff-45d0-a0cf-54804466c6b2">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a8011a7-9bea-4e63-a909-060fb2fd8702">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2af89c6b-68d5-45d1-be05-c2c5be6ada15">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b58efe8e-2b9a-4000-bcef-ea24d39327d2">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a3b5831-89b2-4c99-b1d8-bfb6a4545f43">EV <link linkend="DCM_113921" xrefstyle="select: nopage">(113921, DCM, "Radiation Exposure")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8da859a7-f035-4407-a23e-fa5aa57f847c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6cabc6f8-fae9-44a3-9a51-b3202caeceb5">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11cb9ea7-c475-4912-bc1a-fdb56e824f94">IFF ionizing radiation is applied in the context of the current procedure</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0d4824e-9bc5-4226-92c0-23fe34db33f4"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_68c999b2-566d-438e-9542-1f9878996565">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c782975-5eff-46e5-be9a-71a3e5f8d96c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8d868f2-86ac-433d-9c61-707c0fa32c47">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d098e02-25ea-4329-98aa-66bc4e4eeaa0">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca74d629-708f-480d-8d97-c122daa54c75">EV (440252007, SCT, "Administration of radiopharmaceutical") </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5255167e-bb6c-4b74-90f5-988bcfd5a1e5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_26d72656-72ac-480f-b35e-f17db46c7421">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3ebe1c8-1e76-41f0-a61e-25dfefe78ada">IFF radioactive substance is administered in the context of the current procedure</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_606442dd-2876-4051-838c-40fa3bcfd313"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_fc4d089e-8b9c-4d95-8b31-b1df8c9b0553">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8fcaf99-de96-4d30-9ecd-5a773ab2ffd0">Row 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_60ff6c82-6b93-4dbd-997c-00c91bf27eae">The clinician responsible for determining that the irradiating procedure was appropriate for the indications.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_34222d36-9aa1-48bb-b2de-d83c72b05225">Row 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3914aef3-c5e2-4b5c-a73c-37cbcf5c897e">A textual, human-readable description of the radiation exposure is all that is required by this Template (such as is sufficient to comply with, for example, German law). Detailed specification of exposure is out of the scope of this Template. Such information may be given in a separate SR instances such as described in <xref linkend="sect_TID_10001" xrefstyle="select: labelnumber quotedtitle nopage"/> or <xref linkend="sect_TID_10011" xrefstyle="select: labelnumber quotedtitle nopage"/>, and referenced from <xref linkend="sect_TID_2007" xrefstyle="select: labelnumber quotedtitle nopage"/>.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 2010" status="3" xml:id="sect_TID_2010">
                <title>Key Object Selection</title>
                <para xml:id="para_8f0100c0-8fda-48e1-8709-ca2aa5f78198">The Key Object Selection Template is intended for flagging one or more significant images, waveforms, or other composite SOP Instances. Key Object Selection contains:</para>
                <itemizedlist>
                    <listitem>
                        <para xml:id="para_76b69bac-1fd5-4bb9-8b82-b2c7c601a9b8">coded document title stating the reason for significance of the referenced objects in the Key Object Selection,</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_4d3593f7-a81a-48ca-8b3f-0ff02d0a4b4b">optional free form text comment in an explicitly identified language, and</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_8a97f5aa-54fe-499d-abc3-bb3d871ba4ff">optional identification of the observer (device or person) that created the Key Object Selection.</para>
                    </listitem>
                </itemizedlist>
                <note>
                    <orderedlist>
                        <listitem>
                            <para xml:id="para_ed721201-28e1-4871-bfe6-eaf667b1e577">For instance, when this Template is used to identify images rejected for quality reasons, the device or person performing the quality assessment is identified in observation context items (invoked through <xref linkend="sect_TID_1002" xrefstyle="select: labelnumber quotedtitle nopage"/>). The reason for rejection can be included both as a code used as a concept modifier for the document title, and as text description.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_61c14115-e4bb-46df-ba14-18ef5edd151b">The order of object references may be significant, e.g., when the title concept is "For Conference".</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_c08be380-68b6-44f2-a078-eccce3dc13df">Instances referenced in a Key Object Selection Document may be securely referenced by Digital Signature or MAC mechanisms within the <olink targetdoc="PS3.3" targetptr="sect_C.17.2" xrefstyle="select: title"/> (see <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>).</para>
                        </listitem>
                    </orderedlist>
                </note>
                <para xml:id="para_5fd4b522-d007-44da-8e2d-e27abd9ca4f4">The Template can only be instantiated at the root node and cannot be included in other Templates. The Template is not extensible; that is, no other Content Items may be added to this Template, or the Templates that are included, recursively.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_221627cc-b8bb-47ff-a350-07629aa7962a">
                                <emphasis role="bold">Non-Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4d0a34dc-63da-4fba-9b53-cc6e34457880">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_84925155-bf88-4558-8b4f-974fc4e8c20f">
                                <emphasis role="bold">Yes</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 2010" rules="all" xml:id="table_TID_2010">
                    <caption>Key Object Selection</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1a9a5865-3c13-4a6d-aadb-bec8b96224b9"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d843a45e-d8f6-4422-aad1-f63843b0889a">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bcb247d9-2352-4c73-a696-7b6d00eba95b">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_15fad090-959c-4e82-8d95-e30f987f877e">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3362e379-751f-4b4d-bc70-8fe9fa61e52b">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_700fca3f-7bc7-437d-b597-f9fdbee76f6d">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4dcdcec3-b151-4407-b795-e54c0d0f7bc0">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_77c7fed3-8787-49c1-bc9b-6ee72cf3c0b7">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c38ee96e-ae23-4c24-bb07-48e0edc0b8ce">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d02bcc5-2843-4ba9-aad8-241dca5d1715">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_808aa828-5364-45f6-a189-290946007b63"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c668b594-dabd-49e5-a176-c84963d15b3b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_339e44e0-c5ba-440d-9694-082f13dad390">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce4aba56-4d29-418f-804d-bfe49cb87b79">D<xref linkend="sect_CID_7010" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_407fe943-292f-46db-8118-c288ec3a5a19">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c4abe852-99e4-4bdf-8464-2a8aba74dc71">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8cc279e7-e38a-4a59-9741-3ee230ce37a1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b092c07-80f0-4819-aafa-9cf72a6d39b1"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb5f3820-9cab-47c6-81f3-a1b382749f27">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a140bd6-7aa1-4cd6-99a2-11e59c54ed12">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65cb6067-a183-4591-a29c-03b46660fc7d">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13dcbaa4-3007-45dd-8cc5-17e801200860">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8fc4a46-9199-481a-988d-935f9c7541d5">EV <link linkend="DCM_113011" xrefstyle="select: nopage">(113011, DCM, "Document Title Modifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c920d0a9-c4e0-427d-81e9-c5d322a4964e">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_86799f94-0e8c-49bc-9e09-537be8864f35">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa48f3be-c248-4d8e-8d3a-2c240e280246"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42c06426-36c2-4da8-8bae-7d6b70584211"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1377d767-e9a8-427b-a10e-db8ab8b9caab">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c703e20-af07-44be-aa2d-b73bcd7d703d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08b3666c-d09d-4c89-86b0-0409c671e1fd">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3c5d5ac-c9c9-44f5-8471-e47688f25de0">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17acace2-32ff-467d-9021-8499f5d6b4a7">EV <link linkend="DCM_113011" xrefstyle="select: nopage">(113011, DCM, "Document Title Modifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_91c6db19-af50-4c7e-8391-7cdcf02839d1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f3a2b8b1-f1af-4eca-bc43-02852f48a1d9">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef0c9d17-60b3-429b-86fa-fcf2a66a36ab">IF Row 1 Concept Name = <link linkend="DCM_113001" xrefstyle="select: nopage">(113001, DCM, "Rejected for Quality Reasons")</link> or <link linkend="DCM_113010" xrefstyle="select: nopage">(113010, DCM, "Quality Issue")</link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c95ce81-4b47-4aa5-96f1-bceac319ed7e">D<xref linkend="sect_CID_7011" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0c403633-88e1-4f56-90a0-bef48798ab02">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1641b290-d080-4e0e-8079-26a6d5f281e6">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7180eb8-9b40-4a66-8702-5228e808dfac">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c855b490-10f3-47df-91af-e360d0cf04cc">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b07b6b5-0de6-4b4d-8e58-163beaa01cc4">EV <link linkend="DCM_113011" xrefstyle="select: nopage">(113011, DCM, "Document Title Modifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c7b8d021-e30f-4584-8ad2-623cdf243168">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5856a0d0-a2c1-425a-9ddd-cbcdf6c7ac22">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1f1ea1e-96a1-4b2e-9345-eef8770dbae3">IF Row 1 Concept Name = <link linkend="DCM_113013" xrefstyle="select: nopage">(113013, DCM, "Best In Set")</link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_28bbb45a-4c07-466a-ac91-5438fd26133c">D<xref linkend="sect_CID_7012" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef3a50b0-398c-44ce-85b0-e9c3f33b7545">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4abaa80b-f83f-4fa9-8a9b-b1679d774ac9">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08df3c4a-76ba-44c8-a241-896d972203a3">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0928053e-3467-4704-b503-a7643feaf0a4">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6c4bbe0-b212-4e90-97ef-c6ba532e8b56">D<xref linkend="sect_TID_1204" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc674930-5947-464b-b13c-4821a61754de">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d4fc946e-c877-498c-98cf-e14d88e72adb">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63f611a5-f82f-451e-9f38-1d7ddb568fbf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d19707a-0f38-4eb5-ad56-b3ed233ff5e5"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b56dd490-11e0-4852-bbed-c313461b158c">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7da41906-dbff-4767-8255-f32474601331">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c98b3d3f-bc2e-4ded-b2de-8f9ebf37cdab">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed9d7109-893c-4aae-8c3e-54d1563562d1">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_68498a7f-c613-4b81-b1c1-925b2aea6aff">D<xref linkend="sect_TID_1002" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bd49badd-0cc8-4f55-8b44-d789d5aa7885">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1e2e43bf-4c0a-4662-a917-320bb8596427">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84ef6ade-b319-42ef-a878-c6fe0a67e428"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0b8409a-507a-4d70-97f0-478ff8b8f254"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27327617-e20d-4f68-a712-848049c43deb">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eead6a14-5a92-45c0-bc71-22d094c42592">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_68250331-3243-4272-a34d-69ecf9a9cae4">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1bcfe00-4c5c-4173-93bd-93b1a28d4032">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d07c34d2-5bdb-491d-b2a3-56ea379ba0d6">EV <link linkend="DCM_113012" xrefstyle="select: nopage">(113012, DCM, "Key Object Description")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f9d8505e-8c5b-42d4-a7cd-9c94f0f10317">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_846050ca-34b8-4260-af5d-d3939422a356">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7bc06e39-1958-455d-85a0-dcc676cdd512"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00969451-f844-4875-9099-6539f1fa3349"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0cb2f3a4-65ba-4fe7-b2e1-28131d37fa6c">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83b6dcee-27d1-4322-be67-5e3d7016179d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e241ab2f-dde7-44c3-8943-fd954c0c25b5">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c33ceea-c67f-41ee-bcd8-19904caa2983">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7597194-045f-42e3-85ed-bc177acda8ec"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3a3dd1f2-a93c-4c79-9204-d49f33e054f9">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ac8096f4-d6ae-479c-898b-4acbffae2f9f">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f71f48ff-e509-46b9-a2ab-4f1c5ba919ab">At least one of Rows 8, 9 and 10 shall be present</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87e92975-171c-4cb7-ab56-f00c039656d9"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92193464-88a1-4b0e-8438-b89f7a56d6df">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed2b8642-c233-4c1d-8f2a-5bca895e78e0">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24e191aa-557d-4ad4-976d-ea1b074292d3">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a63c5ba-fd25-4f05-8867-43743950c5ed">WAVEFORM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3835083e-c897-46fd-838e-ed05c0602b6f"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4801b35a-de7c-486f-9752-fcc3cd3df549">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_129975d2-697e-40c4-841b-c22496d8d214">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b322886-d3a3-43ca-b8ec-e02a547c03d9">At least one of Rows 8, 9 and 10 shall be present</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd135221-8647-4112-b576-7b5edd8fbba0"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_307161ce-26af-4619-94a2-099a8ca1bcc4">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b062cf6-81cf-476b-a2e7-8e9e530d863b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ef651f6-e645-4248-8086-5b491f200339">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f7c35d1c-b6f7-4edb-90e8-a76ad2e904fb">COMPOSITE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_34250e04-b007-4d81-8393-77b68ffc4ad6"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_51eb1249-8ac9-4929-87a3-af44aaa12077">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_488ce58e-be3b-4cd8-bd45-f2a1d8110832">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57c5d30f-fcf6-4804-b890-5624d5545f7e">At least one of Rows 8, 9 and 10 shall be present</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52036fd8-43df-4a6e-9374-a96982fda5e7"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_2a4538b0-0d1f-47a1-ab64-0a3ff21b67c0">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c31355a-11fa-446d-94a2-e94e70fe779e">Rows 8, 9, 10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6dae9531-8309-425e-8d25-73d1e43d0e2c">Purpose of reference shall not be present.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
        </section>
        <section label="Optometry and Ophthalmology Templates" status="2" xml:id="sect_OptometryAndOphthalmologyTemplates">
            <title/>
            <section label="TID 2020" status="3" xml:id="sect_TID_2020">
                <title>Spectacle Prescription Report</title>
                <para xml:id="para_35cce27e-7afd-4642-9770-f4745eb310af">The Spectacle Prescription Report is a structured report used to represent the prescription for a patient. Usually a prescription is for both eyes, but sometimes just one. The Spectacle Prescription Report defines a refractive correction relative to which visual acuity may be measured subjectively, and thus may be referenced by a Visual Acuity Measurements Storage SOP Instance.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_039a9f48-4641-45d6-b8ce-b1570cd8c6a8">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_aeffdc3d-93b9-41cc-9b76-afc14a231ce1">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_dd219616-88cd-469a-9149-4693237bdb63">
                                <emphasis role="bold">Yes</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 2020" rules="all" xml:id="table_TID_2020">
                    <caption>Spectacle Prescription Report</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1a7be217-7fe8-48a7-9d73-5ff9340347a7"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2dd691f5-b71e-4671-95c7-5c5da7a2a99a">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_385e4b63-a1a2-4b34-873e-8ba79d71d4ef">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2ce8505a-cced-4cd6-a634-67a2def3b618">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8d3928d1-180f-497f-9e5d-34a3c5ea1ff8">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d215df88-402b-4e9d-97f7-eef9e8a49953">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e5ef1bdf-1bed-4df7-a670-bd8016c9f522">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7bce910-c32e-4200-b7f8-767fa96fa120">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2007c6dc-6ed1-439d-ada7-4d99c2b593f4">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_40784783-74ea-4397-a2f9-891806ad728d">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d72f3e62-44cb-4b3c-94dd-a6dc85f3230f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9385650b-fddf-4c22-94c6-bbadb169d7f0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_637374ee-4e90-413f-b262-84c27269ac87">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f72ecfa-a82a-4507-bc35-fcaf91109898">EV <link linkend="DCM_111671" xrefstyle="select: nopage">(111671, DCM, "Spectacle Prescription Report")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a608f151-fcc7-4452-aad6-5a89fd1590b5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_86f3cb93-8139-4ed9-8778-f7ad1aa298ee">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e6e0c02-1930-439f-82cd-5284fa90c225"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_76466e58-4a50-4ec3-ade6-927e2629e054"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f058ea79-722e-440b-abc0-9539457c662c">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e21bbf9-be0e-42b0-9342-0f962cd8baca">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ad05868-817b-4af5-82bd-3d58504b194e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_874cd09a-f7e0-4476-9d4e-0620b39e601f">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_07ad62e9-6ba9-4b39-873d-56685fa5d1a6">EV <link linkend="DCM_111688" xrefstyle="select: nopage">(111688, DCM, "Right Eye Rx")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f70f2785-ffdf-46bd-8beb-024710208fe6">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2c10e516-eb99-4874-a7d8-e1b9d390e0f3">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_07114b8f-dd9a-4323-88a4-2daeb749d18b">IF Right Spectacle Lens is prescribed</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a1ced59d-6e12-4a14-aa40-11fac7b81c5d"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c056833-e21e-4e56-9397-825a00edec93">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_20cf1bee-da4e-4423-a5c1-5e5f75be8080">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eba07d2d-f63c-46bf-8e75-642512cf218f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d8aba60-93fa-4559-8150-794a2f33373d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af6769fe-d24b-4ba2-aafe-4741e63fa6c6">D<xref linkend="sect_TID_2021" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c7d39e2c-2d8c-4c4d-8de3-75175dad5bf5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_03c8212b-93ae-4e14-b685-578f3543b7ab">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8cdc072d-f72a-410f-99b2-d5537b2cbb5d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37f721eb-38b6-48fc-9cf9-bc4fabd4ea3a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2cd95e2-6fea-423c-b863-13cddff2f598">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_56c7ff21-adab-46b8-97f8-90661812fc67">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fed8d5e3-58a1-44bf-9f07-2ccfb1c9e3fa">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6699d720-ace8-45e8-8b1b-e287e53b6151">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c68fe381-9269-4a14-a02f-e42c9d5fac96">EV <link linkend="DCM_111689" xrefstyle="select: nopage">(111689, DCM, "Left Eye Rx")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c62f420b-c82e-4306-b9b3-d58b7523c636">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9b4828ef-1915-4d3b-b1eb-871941fa5ccf">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b2b8091-8177-4ed8-a13e-481aa55b3faf">IF Left Spectacle Lens is prescribed</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5b559d2-032f-4f9d-b970-d4f4072b5584"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_812474bd-7299-46cc-8e88-b02607b95dbb">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62c7bde0-c831-487f-ae96-ece054feb215">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4cc914ab-4949-4667-b37b-a95a61646e9f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef8e2d92-158d-4e29-8bef-341b869a7d69">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_134f5f72-0034-4094-adff-93df2e7d4931">D<xref linkend="sect_TID_2021" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3ed5c9a7-c6ec-4882-a79d-adb1ab5a30e2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_51802f79-c514-4761-87b1-11c389966bdd">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b06a389-fa61-44e4-9a67-71c7bcb71651"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f115d498-fe46-42eb-b555-de6fc97ce9ff"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13e25008-4b84-46d5-b167-5025a145c490">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62ba68f5-25c9-416b-ab30-aa2787377532">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7813bad9-0cfb-45a0-b2a5-b6e69825a904">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_28d58e41-c4ce-4322-a99d-c7662cb51794">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26d84350-62d6-4e59-accf-5f4426eb12df">EV <link linkend="DCM_111679" xrefstyle="select: nopage">(111679, DCM, "Distance Pupillary Distance")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a00bbefd-a260-4aba-9698-016ba17ad3e8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5b1a6f20-c1c1-4d75-b2c4-0bbb0cd273c1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e257388-6832-4c37-914c-85839675901f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_257ab302-4eb9-4c7e-b768-7a19e257d363">UNITS = EV (mm, UCUM, "mm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_493ed50c-2502-4018-8a44-a2bb8316015e">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ef346d2-83f4-4d0f-814e-b34de172e55a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f63f96f-e364-4b92-ae7e-d56a7e71a696">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38d35e94-106a-42f8-829e-093de1621060">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1669466e-20eb-4223-b671-c1aa9b58c770">EV <link linkend="DCM_111680" xrefstyle="select: nopage">(111680, DCM, "Near Pupillary Distance")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_20f24198-acf5-47d6-ad3d-302d8b42633f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d894ce3a-f0b5-4de3-9231-86f4114cc230">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0072254-5acc-4805-807b-c6c21826b9f7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a92dc0f7-e643-4794-9140-8cc4283cf915">UNITS = EV (mm, UCUM, "mm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_438c7bee-0f35-46f4-919a-2eb5bd11cb5b">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d4a2bce-0edf-4c4e-9cc9-685294c7d1f3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0249f67d-384a-48eb-909c-c8763be5b051">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f09896e-90f6-41f1-9361-c889b61fddb4">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_832d035e-d4ec-4f7e-8244-929985bedafb">EV <link linkend="DCM_121106" xrefstyle="select: nopage">(121106, DCM, "Comment")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85bbaa40-2199-42e2-bca8-d6368fc08e49">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b7065060-fe9c-4d27-b90d-996853391d93">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8efc8af5-2295-47ff-85d0-1bfbe20dfde5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c94732be-2983-4954-90b9-cdf0fb7ee467"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 2021" status="3" xml:id="sect_TID_2021">
                <title>Template for Spectacle Prescription Details</title>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_e193a30c-1c56-42da-86df-caf50d0cebf2">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_fc450d3e-ce19-4c99-8fcf-278952316d49">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_8567181c-3da8-4034-8d9d-6b1f0f973074">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 2021" rules="all" xml:id="table_TID_2021">
                    <caption>Spectacle Prescription Details</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5a498960-dfd9-4bd0-8bad-afa40fbbae25"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d666da91-d798-46fb-9b97-14188a75d526">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e8035710-bac4-472f-80dd-0dad46013ed4">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c27ba9b9-e819-43a4-988e-1c8c104d023d">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2769aa52-80dc-4042-928a-aa2a8fb4c19d">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b8c6d080-115f-4412-85d5-89d6f3293c4b">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8a4012a0-6ce4-41db-868b-ce12ade16d94">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a46f3c29-8a64-4f05-8605-598f5cc2d115">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1f3ef749-5a2a-477b-a171-060169f9bb50">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bdf10b37-e2d3-449c-aabb-2fa1ed9007f5">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_665f4aa0-d0e1-4c32-9cb1-6f09979d1add"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2ea3ee2-cd69-4cea-8610-970def8d4afd">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c37389cf-8481-4816-b0e1-2f48b64a7ad2">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b8e329ff-fb3d-4e36-825f-0f856173c0ce">EV <link xl:href="http://snomed.info/id/251795007" xl:show="new">(251795007, SCT, "Sphere")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ffe4fb1a-52b0-4ff2-9cdf-0e026a8e15e4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9c011c0e-201e-43d3-95ca-329cb5bb783a">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11f42fe4-175e-4caf-af8e-d35004d0fafd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5105724e-c349-4001-8529-2f5f240931da">UNITS = EV ([diop], UCUM, "diopters")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b7032eb-3638-4801-bed3-7c3aeffcf948">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d73e93d7-6069-40a0-b22c-a8dbabe12b7d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a126fae9-70c4-4056-91c1-72513d1ffeee">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_412d9fb4-11fc-4c49-9dc3-065e08d19610">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_027da794-aafa-4e80-83e4-86626486e8ef">EV <link xl:href="http://snomed.info/id/251797004" xl:show="new">(251797004, SCT, "Cylinder Power")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b3af30a3-beb2-4bd6-a4f1-35c468bc648d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5a4cac66-2101-4f0a-965e-d5a95e1015ed">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f33b673-a499-4c8b-ad3a-8e97f4423e87">IF Cylinder is prescribed</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a63846a8-9082-4494-9ffc-ffb151c68090">UNITS = EV ([diop], UCUM, "diopters")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4b86c66-ff6a-4873-a86c-14eef2f5bc5d">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aaa3cf64-352a-449e-ba77-c379e8b9e087"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_14db8323-dab9-4e4b-ac7f-9f9b0a59d3a5">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d17650c-60e3-4503-853c-f94316f25067">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b77b872-0c61-4602-bad6-f76504155321">EV <link xl:href="http://snomed.info/id/251799001" xl:show="new">(251799001, SCT, "Axis")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_db61b4c4-514b-40dd-8e4b-e108a6d16d33">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0456c92a-5376-4453-a786-772093b39309">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd2ca174-379d-4bba-a2f8-7c31aebddc05">IF Row 2 is present</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f60813f8-2c3d-4e1e-a5ed-ab79b40b6117">UNITS = EV (deg, UCUM, "degrees")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5261f78-8d61-4f1b-a240-ad3fddadef35">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8f29654-6a7f-4bdb-9f3d-354245c7454c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_15694262-6f65-4893-91c8-e9f703523b4d">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5915c8a9-62be-4550-9290-83b6285e9251">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a98e662-efaf-4b08-b684-1edba7f4f812">EV <link linkend="DCM_111672" xrefstyle="select: nopage">(111672, DCM, "Add Near")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cdc8c694-701d-40f1-a056-7f7630bc099d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85d3999c-43b5-4028-bbfd-472fc6eb93ee">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d281bef-870b-4f57-b946-a208cc537baa">IF Add Near is prescribed</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38737e88-382c-480b-9269-7ca36e4e59f2">UNITS = EV ([diop], UCUM, "diopters")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35056357-e75f-4616-bd02-8c89d673464d">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d3a1f43-3538-496f-9889-9c26bc0b5cdf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8944a144-2da4-4d8c-929b-82bdf2d0ced3">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_94029846-d585-4333-831f-3b3c6872ed53">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e32ea894-9c18-4c1b-80d8-d4d58893dd81">EV <link linkend="DCM_111673" xrefstyle="select: nopage">(111673, DCM, "Add Intermediate")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_20c700e0-4af6-4722-8ca6-230886d38078">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f53ec821-6a66-4242-aaaa-523a80789333">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a50d7a3-18a6-4d9d-a8e1-7ae5d21bbdc3">IF Add Intermediate is prescribed</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_397504f0-4b82-4932-bf14-2384d1c3ed7d">UNITS = EV ([diop], UCUM, "diopters")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8bc6b25-e30f-41bb-9689-d591689717ba">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c030fa72-eef0-4602-b143-55a1ef9a4e36"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1a4b4ff-6bdd-40b5-a56a-743db2a11e9d">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9761bde-0cbc-46f4-9b82-59e2ac585267">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67054f5b-2bdc-4b9a-a83a-5ecc1da643a0">EV <link linkend="DCM_111674" xrefstyle="select: nopage">(111674, DCM, "Add Other")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_77c27836-b84b-4be5-8d12-5bbf1e3e14ac">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_05f58c7a-77dc-4993-8be5-d41811cad776">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c894575e-adf9-4b31-83d4-c62feb04a423">IF Add Other is prescribed</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_187fafe8-0063-44f9-8d99-2b194e45d368">UNITS = EV ([diop], UCUM, "diopters")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ebcc31a1-3b1e-4163-9670-5ca2365d22be">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd31c106-e5ec-486b-b990-4204b869a352"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2fa2664b-1b32-4ccb-ad9c-a01d4783707c">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82d3ecc9-752c-4ef4-8ce9-3e2c3a976357">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad2a46b3-565e-4dc2-9808-f9c6d1b5fc5a">EV <link linkend="DCM_111675" xrefstyle="select: nopage">(111675, DCM, "Horizontal Prism Power")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6fc2fd5c-30e8-471e-8512-23a1145f0202">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_77a7e1a5-3f9b-421a-a5d4-32d385abfc36">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_efd97bd9-9b05-42f5-a6c4-93728858950a">IF Horizontal Prism is prescribed</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9a02788-8070-4eac-9f20-3c8d84804403">UNITS = EV ([p'diop], UCUM, "prism diopters")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa4df19c-0bc7-40e1-844b-e031f91496cd">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03b31191-81c2-40fe-99eb-5fc0d638af22"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ddf9524-41c9-43ed-984a-fa20d81b7d83">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_689fd588-670d-4820-a04f-50a33d30f642">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b2899e1-7282-4efc-adbf-3d087f610b3a">EV <link linkend="DCM_111676" xrefstyle="select: nopage">(111676, DCM, "Horizontal Prism Base")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_399f29e2-09a8-4add-9e05-b340844aa370">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9f2bfb2e-adf4-4a17-8a67-8d5e0cf85067">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3bfa40c9-adb8-4804-86ec-087ec0b1d349">IF Row 7 is present</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63726776-4b72-439a-b227-f62166eb39df">D<xref linkend="sect_CID_4214" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9555f466-f503-456f-ae88-8b62299d6887">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b94b0963-80a4-418a-825f-c93bdd4b1306"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4b3670d-6163-4c73-a308-8c7254e0ff06">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d7a18f32-3481-4207-b1e9-6a5e58ffdf52">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87c402a6-1e39-4d81-a704-ccf83fa221db">EV <link linkend="DCM_111677" xrefstyle="select: nopage">(111677, DCM, "Vertical Prism Power")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3e4f9985-c94b-4055-b083-41ad753bde1c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3f4f22b6-bd2d-49f4-8884-669c5199860c">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dde0c357-328b-48d9-a691-dfad462f2515">IF Vertical Prism is prescribed</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6014c89b-f3ab-48f8-bcec-da625d1c6634">UNITS = EV ([p'diop], UCUM, "prism diopters")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c42c9240-6c3d-43b2-a1b4-e89c87991930">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6402ec8-842c-455d-ae14-b807d635c95e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99af28b7-2871-4ee7-9291-f88c888604c9">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b9942767-cb5b-4462-88dc-ae60b9c992a8">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d686975-2c91-4757-bfbe-797b9334718f">EV <link linkend="DCM_111678" xrefstyle="select: nopage">(111678, DCM, "Vertical Prism Base")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a21496fe-91fe-4eb5-aec3-7a597dc429f9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c037fe3a-3758-4056-9386-fd37b468dfdd">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9624db3d-a868-48d3-9daf-c0ef47d1a83e">IF Row 9 is present</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de64357c-0232-4771-b9df-5bf23abd5391">D<xref linkend="sect_CID_4215" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_beb5cf8c-8074-402d-9e08-3f3aaa2f7e70">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5fbb736-750e-4881-8fd4-75a1e30281ad"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25991677-1d3c-457c-8328-4fed09334001">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc119e17-8c28-414d-97fd-d4b51fad20d1">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aaaf20ef-e886-4ef2-97f3-d8b84267631d">EV <link xl:href="http://snomed.info/id/415813002" xl:show="new">(415813002, SCT, "Vertex distance")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_abdeef5f-5ea6-488f-a07c-485e4e48f26c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e0079bb2-da08-4849-b29d-6a174a64df29">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cbf0a078-5ee4-4233-a028-296b2e409ae3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48b1e1d5-fbc8-4413-b71a-6e3cc17bb7fc">UNITS = EV (mm, UCUM, "mm")</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 2100" status="3" xml:id="sect_TID_2100">
                <title>Macular Grid Thickness and Volume Report</title>
                <para xml:id="para_fd1fa1c2-7265-47fb-9145-b7ee74678522">The Macular Grid Thickness and Volume Report is a structured report encoding the macular grid thickness and volume values derived from ophthalmic images, such as ophthalmic OPT images. This may encode measurements of either or both eyes.</para>
                <para xml:id="para_c3ba78e3-eb1b-4d12-8a2e-f19aad8adf6f">The macular grid conveyed by this report is based upon the grid employed by the Early Treatment of Diabetic Retinopathy Study (ETDRS) to measure area and proximity of macular edema to the anatomic center (fovea) of the macula. See <emphasis role="italic">ETDRS Report Number 10</emphasis>.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_803db5f6-a3be-40ce-8eb3-cec604e01b9a">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_26b1bce2-73dc-4314-9c8d-c7be01a98569">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_54cb8e93-8cd5-4193-97f1-d5a7979306fc">
                                <emphasis role="bold">Yes</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 2100" rules="all" xml:id="table_TID_2100">
                    <caption>Macular Grid Thickness and Volume Report</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8122cb0c-02e9-46b8-9b03-c9ffb5d9b550"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bca7c06b-bce2-4834-93ef-56c4d6829bc8">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_10680869-47a5-4a7e-96a0-bd13d2d6417b">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85619b78-b100-44c6-b2aa-35b7046fb255">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d54bce9a-a309-45bb-ba17-ebc88be7973f">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_29c6a684-7b93-4054-b4af-3ecda2f2c483">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_447129fb-a465-44e5-935a-b21c898ff3f1">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9d7ace0e-a435-46b1-b068-535f5a751b6d">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_75482835-88cf-42de-9a73-b1c8e61e2481">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e5eaa1b-2f6f-4c56-a413-d286afa5a3fb">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae4ed387-2520-4bae-b1b1-af37d01e09f7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d4fc00de-6d70-4bc9-9121-686fc72cf7f1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_28911069-b48a-4981-a32b-15c5da54a8f5">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c593d77f-14ae-48e5-85fe-d4be7227cb7b">EV <link linkend="DCM_111690" xrefstyle="select: nopage">(111690, DCM, "Macular Grid Thickness and Volume Report")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_91570572-629f-4432-a342-cfe20fc0ce3f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_20cf32a0-5195-4285-a2d8-4381ff1b040a">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_827e8446-c1f4-4143-b30a-625d911623f4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_feb70992-d281-4fbd-a111-75afc0f526c8"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e475a170-1f45-49ec-b417-8ebb9514ff0f">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6805a55a-ba74-43a9-bde0-7884e0dabd90">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e10f0f99-be6b-4ef7-8d07-734bba52d189">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eed68be5-1563-44fd-adc4-deb175b6479c">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c96597af-6c56-4018-8004-ba9d9fd4a6cf">D<xref linkend="sect_TID_1204" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d2be36ee-04d6-4769-9d4b-a04adcbbf9e8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b121bdb8-09be-42b9-a8e6-9b00146a3051">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b50684f5-2a87-47e1-a395-d92c4c637d74"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec1b9623-74cd-4b64-9fc7-6c7a362cbe49"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58bfddc8-439e-445f-9d7d-0d64dd82280f">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1230a8e4-4eac-42f8-a521-15a34a7e6199">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b65107b-290f-4bb2-bfa6-5c6ace64093a">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df816787-d011-44f2-bc79-bec502a0cd03">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c86c4648-655b-42e6-aaff-e602a7a3632d">D<xref linkend="sect_TID_1001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d9c08623-0d54-4970-9729-40bc9287ea6a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d94b4697-c7c6-4052-975a-d3e54752f223">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c00430d4-5a47-4012-b3c4-a6aaa4a3f4ab"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c64d3b52-dd2b-49e7-9050-67a92e1aac6b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02db8524-8694-4c53-a5d4-53ce70e61848">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_702db321-cfa4-454e-8195-1ee30c6d00a7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6e39bb0-00f4-4b61-aecf-288f996f2859">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59e7c363-7ddb-4149-9917-e8ac1cc78329">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38b4b93e-ace3-403d-9821-45ad33974c22">D<xref linkend="sect_TID_2101" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_beb2caa5-541c-4091-9be6-f04de6f6ef6b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_71408f4b-d500-489f-93a8-559e903f7e0d">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b53a082-fb82-40ac-b63b-700c10624367">IF Row 5 is absent.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2705c0d1-5ea7-44b5-80ef-6178502067ef">$Laterality = EV <link xl:href="http://snomed.info/id/24028007" xl:show="new">(24028007, SCT, "Right")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51c1da2e-1dea-4329-969d-e3cc904b7a03">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48fdd2dc-08ed-45ee-828e-04538cc83cc1">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2eeb04bd-88d6-4810-b6f3-4de05bc441c1">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79ddb6a9-6bf1-418b-bcbf-50f7c7dd3b9a">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2eacd299-951c-4fba-8dca-ab5e2e231509">D<xref linkend="sect_TID_2101" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1a24dca5-fb62-4f86-b334-af24e5a3cf18">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_23bc190b-36a7-4993-bab4-5c28b29113f1">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c3d949a4-f2ce-4658-b230-4342efae73b9">IF Row 4 is absent.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e7b13c8-88e9-4055-bdb8-70880dc699e0">$Laterality = EV <link xl:href="http://snomed.info/id/7771000" xl:show="new">(7771000, SCT, "Left")</link>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 2101" status="3" xml:id="sect_TID_2101">
                <title>Macular Grid Thickness and Volume Measurement</title>
                <para xml:id="para_717bca63-f6a3-42bb-9803-eac271043828">This Template encodes the macular grid thickness and volume measurements for a single eye.</para>
                <table frame="box" label="TID 2101" rules="all" xml:id="table_TID_2101_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b3de7b79-25b4-4530-8eb7-5486d14b1630">Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9f2b405f-1ed4-46ac-9f54-c2d3f16a662c">Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b8560e58-39b3-4a5b-9214-8a98a6a4af8a">$Laterality</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c773bcf7-6971-41b9-8bce-64706a1fa545">Which eye</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_0d0b6d05-6a9b-406b-8e43-5fb191027d6b">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_7eb84a88-e664-42ce-8142-0b962f0f8386">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_50e8a41b-b6b4-4ee0-b39c-882be5f7513c">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 2101" rules="all" xml:id="table_TID_2101">
                    <caption>Macular Grid Thickness and Volume Measurement</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f30e6ea5-51ba-4993-a829-71ba374f5f26"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_98153dfa-1b3d-4c01-aef8-4331f90acf62">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ad45162f-3ef6-4363-80f3-f04ddb8bc8e9">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8b6b6b02-3888-4d70-9c60-f1d6ed713158">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a3f02300-1afb-4064-8d4c-255289a7ee0f">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f4cc5cfa-0445-402d-a39c-b42feb59f975">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9130ff82-6149-40c2-abd4-87d806fd1256">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf0665c2-4c25-4a33-a570-2d0237de33ea">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2489c311-e77c-4a02-a3f4-77879aa1c734">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31577d9e-f2e0-4464-9ca3-256731039c8e">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_33c90797-4783-4ccc-a732-088d933a39a8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3279da5c-afc6-47f1-887e-4a1f659333d4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51bc9c8b-87f2-4363-b5d0-8b1ca54d9353">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_764898d3-3cd3-42ad-82d7-78e193946841">EV <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8a615b45-4ee8-4062-bdd9-58dce198cbc1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_925d31d5-9af1-495b-83b6-f9df2917e01f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9690d93b-0f63-4278-88eb-98d7bda6e907"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4b236eb-665d-4edb-9b6c-7a0b9efc3170"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7a7da7d-d5f8-42a9-8628-af5e9a520b01">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99155a32-c23b-401b-911c-a8f39f01e80d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51cc3ade-4eff-4e29-a62b-2ae95f5c1489">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5efa7828-4d4a-429d-a8f9-6400db42c0b2">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6c0d30f-bfb0-43b3-87b6-77fe45b4fff3">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_be8222c8-9d15-44d0-ae40-b1c653f1388a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f1e92064-9c34-474c-b57b-49a8e09a1c7e">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b8988160-0098-4e29-a342-8cbb6aac9fed"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d40329a-bda5-4da5-bdf9-62f85920e365">EV <link xl:href="http://snomed.info/id/81745001" xl:show="new">(81745001, SCT, "Eye")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2405f9d9-efb7-4301-8a22-2e0b38043705">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e637530-532e-4612-b49f-33f5704d6feb">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_791422c2-4463-45d3-a2b6-dd80553e9648">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63714f4c-fa73-4be1-b83c-32b5d05a2b0b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cfcf66a3-eb7b-494f-9ec2-8c1d478e4e5b">EV <link xl:href="http://snomed.info/id/272741003" xl:show="new">(272741003, SCT, "Laterality")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2478ba6f-131f-489a-b310-a85b419ce2bd">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2d3e80c5-0d99-4970-9959-ef9accc4a222">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4b01507-9d36-4cde-802d-0c541d62a36e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b081e3ee-a929-410f-b1da-4fa8756651cd">$Laterality</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0448c885-a81c-4063-b7bb-0bfa5d3a02d5">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4a6b647-d9b8-4a96-81c7-374f3d2e1683">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b71c619d-8b86-43af-b26d-894a3150b6e4">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21186f37-cbde-4ad9-a279-e0b24773f358">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ccdf299c-47ad-4b9a-92f8-c2ef34970f51">EV <link xl:href="http://loinc.org/57108-3/" xl:show="new">(57108-3, LN, "Macular Grid.Center Point Thickness")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e20ed0fc-8020-4f80-9e84-789654a17b39">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d3502ab2-2d41-4f2c-b9f4-c65c58fac425">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ebe3f696-08cf-4db0-9f52-c6e87f0366e2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ca0451a-3cc0-4f16-835b-68cbbfbb67ea">UNITS = EV (um, UCUM, "micrometer")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93f56d23-8842-4ab1-81f7-26556d7ae2fe">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_380258e4-8815-4722-9021-07345a162471">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3cae094-c03f-4859-936b-766068c9d6c4">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8a7d118-1539-4507-b1fc-6a3d975b5277">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bfeb2ea9-7e15-4852-8820-f24762cb073c">EV <link xl:href="http://loinc.org/57109-1/" xl:show="new">(57109-1, LN, "Macular Grid.Center Subfield Thickness")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bca4c57d-1d57-42a7-a6f3-c1a071a976ab">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c9001bbd-93ec-4da4-9bb6-8897a3908747">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84a3f623-5a5b-43c1-a348-0894b677f4c9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_53158a02-ec3a-4444-bdff-5682b1e030cf">UNITS = EV (um, UCUM, "micrometer")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9735342f-f1b4-4627-b71b-cbd22d1cb0dd">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf66c43a-e4d9-4c36-a911-7bb2ddcc24de">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_177522b3-7d39-4206-b1b2-861cdff62396">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_712de9e3-ae93-459b-8e23-4719eb5ae6f5">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2493b5f9-e9da-48a8-bc81-ff7c2d43e846">EV <link xl:href="http://loinc.org/57110-9/" xl:show="new">(57110-9, LN, "Macular Grid.Inner Superior Subfield Thickness")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8fdd9f6f-4432-4cc5-b535-0c8bb68d51a8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4000243a-9579-4980-8995-2b40c40dfac8">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d9a40fe-8292-4248-98fb-a636f754dc17"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_28a2dfcf-76ac-445c-8a65-4ef4fe8d165b">UNITS = EV (um, UCUM, "micrometer")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24c2f4ad-637d-414b-b63f-57e80ba8f3b8">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b5e8310-daca-431c-ba4c-1bc4ae853234">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_332055bb-afe9-4f44-8d7f-deb147badac7">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21efbf71-202e-4640-a409-19409740228c">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da3abf0d-a247-4472-994d-8b4991830143">EV <link xl:href="http://loinc.org/57111-7/" xl:show="new">(57111-7, LN, "Macular Grid.Inner Nasal Subfield Thickness")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1a05f25e-4945-49c9-af7b-a6a996eb99d5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1f022f2f-5f18-4e82-ab14-c8cedf6c7805">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e87719c6-da5f-43e9-8bc7-d59260631dd8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2544f76f-d50f-4f40-b7fd-d6e04d55c6af">UNITS = EV (um, UCUM, "micrometer")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55861af1-6feb-44d3-84c4-ce39916ae49e">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef73d8fb-ebba-43b9-9642-797cd02b8651">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ac8c569-1fd6-4df0-b550-b605ffbcea0d">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dfb16481-66dc-4ee8-b15d-a5506a029466">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d6dea9e8-6119-453a-aeff-d2a2d76ff113">EV <link xl:href="http://loinc.org/57112-5/" xl:show="new">(57112-5, LN, "Macular Grid.Inner Inferior Subfield Thickness")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c0702f23-c6f5-42c2-b1d6-b1e52ed8994e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_42068bfe-9f0c-49ec-a3b4-680ea6807593">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fcefec9b-7177-4fdf-baf8-9fdff3c41aa8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0301303a-bc7f-4af0-8117-4e33605cce68">UNITS = EV (um, UCUM, "micrometer")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1dfe8a0f-4e07-48f0-85b8-b4773b01d730">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83f41814-b64b-424f-aeac-c6904c4a2e7a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83193235-69b6-4941-95ca-e13126970f3b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_034df12a-bcec-433a-8c94-c84e264ffbd8">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09ca8cb9-f15f-4488-9a8a-96be672ded9f">EV <link xl:href="http://loinc.org/57113-3/" xl:show="new">(57113-3, LN, "Macular Grid.Inner Temporal Subfield Thickness")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a6b3bfd6-d3e6-40b7-9dcd-b8bba6959ff3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cac26510-c401-4f81-ae57-5e5a693a3a85">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a524711-7be0-4a0a-9871-154f76ae3b68"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f615571c-5ceb-46a4-8b84-4526b697a895">UNITS = EV (um, UCUM, "micrometer")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4a876bd-f85f-491b-85ea-ce02bb972fae">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_600cfcb4-f2ef-4e44-bafb-26bff79c90c1">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_76a07e73-c972-45e2-95b2-0955634995e4">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a56bb9e5-4e00-4427-bb21-d971b6ab3427">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a2c23dd-e8ee-48eb-86d8-c02f7538a7c1">EV <link xl:href="http://loinc.org/57114-1/" xl:show="new">(57114-1, LN, "Macular Grid.Outer Superior Subfield Thickness")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_94ae8cde-77df-4d8c-99d3-d15d9bc1a029">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a5a7177a-ab44-4480-bdcb-ddca19c128fc">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58270a1a-7ab5-44ba-aa0f-27387ddc5625"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_76a08f28-744a-443e-8543-1415e8d778d5">UNITS = EV (um, UCUM, "micrometer")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a956fab1-2c70-4d9c-aea7-3be102a56bfa">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54d630ea-3a60-4b0e-8133-dda9868ce47a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4087b1a8-d7e7-4f95-a720-a512b5909b66">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fdd3e2f4-6c5e-4dc9-adc3-62c24a7b02df">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e32be38b-182f-4d88-976c-adbc37443f35">EV <link xl:href="http://loinc.org/57115-8/" xl:show="new">(57115-8, LN, "Macular Grid.Outer Nasal Subfield Thickness")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0106841b-e8d2-4ff3-90f0-321cdb06ce37">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_06f112d5-1d4a-46f5-b59e-ba76e39b643e">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b90a025c-1389-4803-927a-1d91e7e66fdc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74bc87e9-b368-48ff-b5da-39e3cef47eca">UNITS = EV (um, UCUM, "micrometer")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5eda7bf4-9b53-42c2-9483-abfab17d1eae">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b11c0bd4-7064-4b1e-b13a-50f84004765a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52abf314-79fe-445f-aa39-8c4a487f0ddd">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c3a6b4a1-f148-4d48-9d43-3bee3eeee1cb">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_66635e08-9e77-4df0-ae53-a37e042e9b39">EV <link xl:href="http://loinc.org/57116-6/" xl:show="new">(57116-6, LN, "Macular Grid.Outer Inferior Subfield Thickness")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6724b268-414c-437e-bbd8-8f650f284340">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aaef41bd-c13d-48fa-ab50-3cee13f87a0f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c159f8b-951f-4381-8e99-b91fdb6efa46"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e1a67d6-a461-4917-9176-8824a8c1ed1a">UNITS = EV (um, UCUM, "micrometer")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d4a03f5-0d1d-4f7a-9cbc-90ebea3aeb2b">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67338682-6245-49cb-aa46-4ad906b4d0f1">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_535cd9db-06d2-46df-8222-763f4d6aed2c">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_90bbaa5c-63e5-4f15-97c7-df31c347917d">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_664ef4d5-472a-4d09-81d7-3c45c0400bfc">EV <link xl:href="http://loinc.org/57117-4/" xl:show="new">(57117-4, LN, "Macular Grid.Outer Temporal Subfield Thickness")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_050a725d-104b-4e6c-a3a4-d204bd1ea547">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c8130455-5d54-4be0-b74b-80c7b6f4bbe6">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8da7a3b1-4631-4d40-83c0-c4a23cf7aabf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c3952f8-e2af-4818-8e55-1bd7e0775172">UNITS = EV (um, UCUM, "micrometer")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_132f7782-4308-429f-822d-98b8fa794810">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b46ded22-45bd-415c-ba1e-aca8c95e9a01">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d58aeb3-5ef7-42d5-b698-34f659576909">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d43de6dd-1306-4a25-99f9-80202e4f8a0c">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6da830f7-91dc-4722-8061-e54b524b48e1">EV <link xl:href="http://loinc.org/57118-2/" xl:show="new">(57118-2, LN, "Macular Grid.Total Volume")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_51daac0e-fdfb-4ed9-b810-759a86355f8d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_65a15930-da00-451f-8ebb-0a38b982bae6">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_71f8d902-d62b-4917-b356-440551e4a4d8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16d00aa2-9c6e-4244-aad8-287bf1ae7cba">UNITS = EV (mm3, UCUM, "mm3")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_45a3aa82-a5e9-43ae-b4ea-5e72f53e0304">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb3be814-5f6d-458e-8c73-593f005d32f9">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65133b3d-7f43-4066-aa3b-3f376d7ce20a">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69e062bf-8447-4103-b9fe-80c6b1fa5cf1">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16932951-c0da-44f8-bebc-341291ea6f3d">EV <link linkend="DCM_111691" xrefstyle="select: nopage">(111691, DCM, "Number of Images Used for Macular Measurements")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_433561a5-887b-4715-bcfb-b7b43f7a18b1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_915edb5a-b309-40fb-9b9c-ed79519ef4a8">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff8ef88f-12fd-4004-b55b-a47a980b7e44"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05d7d042-1a04-4a91-84ee-13999b5d0c8f">UNITS = EV ({images}, UCUM, "images")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13f496d4-020d-42f5-900b-d75a08978832">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_598a8f3d-6161-4c2a-b621-5b6b3ab34b96">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97119e61-2e4a-49b8-b42a-8844aa42aa6e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_efa5cb59-ea71-4cfb-8d9f-9bf820dfa1a1">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d667401e-0929-44ce-a892-62049536e7ad">EV <link linkend="DCM_111692" xrefstyle="select: nopage">(111692, DCM, "Number of Samples Used per Image")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_295328c9-c46e-49ea-adce-3d1f158e2058">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eeb00f8c-95cc-4e48-b8d2-f42780c2102b">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_abee270f-b30c-47e2-a8db-0229d8afa3b5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3846934d-728f-415d-b1ea-0747a88c7fbd">UNITS = EV ({samples}, UCUM, "samples")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d371d3b5-e79e-4a3b-ba4b-88e033cad28a">17</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6375dc40-8a31-4f3d-9a11-025d544ccc3d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef525b61-1541-417e-b839-b8ebca7d1ef6">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1d0e280-6334-4a6c-873b-7e3cac0ebac9">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8ba9116-3e81-4d02-b6bb-e52f01d14fd1">EV <link linkend="DCM_111693" xrefstyle="select: nopage">(111693, DCM, "Analysis Quality Rating")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_91e0f8fe-51d9-480b-b12c-98d4fac4970e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_03ccd439-1916-4700-8741-6295ce7ea136">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0111e260-2e0e-49c8-9c50-3376f8929f7f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46247280-aa30-4668-9133-d777a3d576bd">UNITS = EV ({0:100}, UCUM, "range:0:100")</para>
                                <para xml:id="para_7e8904cd-3fd8-4e3b-8590-360752a8a4b7">Value = 0 - 100</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0552522-882f-4d68-ab76-c1303d08bb1a">18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_990a6382-d001-4e62-b84d-05de1d7cfa69">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3196713-0240-49d0-a3bd-64d60a747153">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a501ff42-db1e-47f7-8aac-4e95688d71c4">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74fe6e3b-10a3-46cf-8085-049622397ff5">D<xref linkend="sect_TID_2102" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e5681999-f5d4-4b38-8468-30ce32ebbdb7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4fc88771-c3b0-40e8-a5ce-1eb4e3f55bb2">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1736a3a8-6465-464c-b275-c00cc2a8e5d7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e2bb5c3-bb8f-412b-97c2-8e3be3df68b8"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b30099d-5916-4bec-8380-e3e824946ac3">19</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e46c47e-3e58-49e9-8dd1-d02a4d15a3fe">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a53f15f7-71bc-4a37-9114-ae9a54c0f6aa">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3dde2e9-1ebd-4283-b3af-3648b3ae5759">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16aa5a42-0941-45e6-bc64-be6fabcbc35a">EV <link linkend="DCM_111694" xrefstyle="select: nopage">(111694, DCM, "Image Set Quality Rating")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_68227131-3246-498a-a543-750b560bc02c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_417a2bbc-fccb-4b15-9f7b-ceda0b70e524">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f335945-d946-4536-b8db-337d9ca0ffdc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6de415e-8d35-4127-8700-18d6a61fcc7b">UNITS = EV ({0:100}, UCUM, "range:0:100")</para>
                                <para xml:id="para_ec69ebd7-97fd-453e-8c7a-99582472874c">Value = 0 - 100</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da747cee-38b5-4e8b-8c0d-968f270b65c9">20</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_868e4bc1-7151-4ca1-a8b4-393867b5d6c5">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0757b773-df0d-431c-a33e-a4b9d216a40c">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b37c676-7dc7-473b-a56c-3a1135ead703">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3762973-6d5f-4efa-aeb4-51debc5a58ec">D<xref linkend="sect_TID_2102" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8b3c1c2c-3947-4da9-94e5-d6fad4c88b99">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c2a96e21-0379-4f69-bcf2-f3ed5a7a2d8a">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c042248e-a489-452f-895f-389c4de53b30"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c85e87c0-8d7a-472c-976e-035330e8be17"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_47fc0851-8f20-43af-83c6-167dd058fa08">21</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57d8923f-aef1-4782-90bc-5723b538c224">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a3db94b-4067-4897-936a-54d648c4c3b8">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3301f82a-0db7-40ed-9a2a-0aea49146d51">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43c5c595-9da8-4c9a-afcd-cb9dde40e087">EV <link linkend="DCM_111029" xrefstyle="select: nopage">(111029, DCM, "Image Quality Rating")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_90e44d82-cb3a-4145-b716-9624d453af62">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c13633bd-291e-4ebb-9c86-a6549f70fce4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a843f026-2f5a-451c-aea9-28990a070322"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f13dea81-b44b-4346-95a0-1afca051793a">UNITS = EV ({0:100}, UCUM, "range:0:100")</para>
                                <para xml:id="para_3f25653b-1fa6-4cfb-86c0-7d8b9b656fcd">Value = 0 - 100</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e0d10cd-37d1-4742-918e-8a3345b35c9b">22</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fdbb73d5-4e6c-4b59-ac8c-6ca51bc9c499">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7a090af-2733-40ae-b942-08e774642506">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_acab9deb-8698-4b4b-baed-8a6edfc67de0">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d078219-b9d0-4089-b709-cd5dafc75db9"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e273688b-6a5e-4985-8699-c7764cc66000">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_25ccdf45-2b34-433b-b3c9-7b3c6728b648">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5ae74a2-39e9-4405-89dd-eed78becf251"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b15d4bed-19b0-4bbf-b7c3-55625de7c15b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_78c0692c-f05a-4916-925a-80f9a03201be">23</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e1baa460-4459-4015-8cb5-4b9ac19eccc3">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97f16188-e1b2-4798-8783-b54a5b1f04fa">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87f704ad-de55-4379-905d-79bd6b5b9791">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13b4d407-9e96-4c8c-a505-54193954589d">D<xref linkend="sect_TID_2102" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_14176ad1-1d37-47a1-abf3-9b199e5eb2c7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2b985d96-425c-4356-b5e6-171cc54e1c3a">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_340a64be-4048-47e2-9604-9f6e40037d90"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ac32b37-d675-49f2-9530-6dee150fbd8f"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3956586-ebfd-444b-bd68-12480c854988">24</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1f4f7e08-458e-4cc9-b167-db2ae2de172f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83308741-afe2-4f6e-8f5f-0aa6f0ee164f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_848cc8fb-f5ab-47cd-a67f-7b31720b49f1">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef1c404a-a6db-4e4c-8835-5e856b7f046c">EV <link linkend="DCM_111696" xrefstyle="select: nopage">(111696, DCM, "Visual Fixation Quality During Acquisition")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8b6f6055-764b-4759-947d-c0297894ff59">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69132018-a05a-4dc9-be0e-31b8f185d83e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38b0cf14-0ae1-4799-bf83-74abb4d3cbc1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f7da1ac3-ee81-490a-a275-54525a6becfa">D<xref linkend="sect_CID_4220" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99ec9528-9df2-4e13-a11c-77e6a9bdd15e">25</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_628b6716-0d54-4a87-bdae-3da72d71dd2e">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6041c80-d7ea-45f6-abbb-4392e5bf1936">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5acbcfa9-cee7-4e26-96e1-7c52348c389f">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb12fb44-4a11-474c-aab5-6c9329a436b9">EV <link linkend="DCM_111697" xrefstyle="select: nopage">(111697, DCM, "Visual Fixation Quality Problem")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d41594cb-8d50-4355-96d8-f47fc04bd0d0">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5e49e1d6-7c58-4e64-a788-360423805a09">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba83ec10-7386-4c96-b055-0a4e4a0178b6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f811351-ca06-4ff9-bde7-39a92ff71b15">D<xref linkend="sect_CID_4221" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f3489bf-e785-4331-a7e5-6bfb4b4edfde">26</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e8da5fc9-60db-44f8-8fbd-649f1e43f4bd">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c341858-5e93-4cf6-8717-857b329f8f4d">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80a064cd-c774-4e9f-9cdb-e648defdcb7b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3e72cfb-e81d-436c-a7c3-76d9201b253c">EV <link linkend="DCM_111698" xrefstyle="select: nopage">(111698, DCM, "Ophthalmic Macular Grid Problem")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_308ee024-7f39-4abb-b544-222b1f2a62f7">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c95a7ce-ca40-44d3-b55a-33d65dff0500">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e8c4bb07-6cc6-4d2a-8938-a0fe9b6e394b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_565d93f7-999b-420a-a33c-bea7072c7fdb">D<xref linkend="sect_CID_4222" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bac44577-7695-4025-9b75-8f31115ac5ea">27</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed8b2d3a-590f-4486-90ad-64bc53894b5e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6189674a-d1a8-4bcd-bda1-cf6ea5e3423e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c982084e-0343-4562-a1f4-4ba3f67cb5ae">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9f9f35e-8ab7-4855-ab93-9285f1b935c2">EV <link linkend="DCM_121106" xrefstyle="select: nopage">(121106, DCM, "Comment")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f72b6ac2-fe7c-4178-a91e-f0eda87f0091">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a744b3bf-bc0a-495b-934e-25bbe600bb84">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30ec517d-0868-4e49-8e73-11784cc426e6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2834f0a-1d16-44cf-98d4-8843f6a7ce3d"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_3f8b04c0-e42e-4ac8-8064-3dfe42557526">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_039e6b1f-4c76-4f09-a3d1-793e62dc159c">Row 22</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63f8b1f1-4921-4099-bedf-fd6abb9e8883">No purpose of reference is specified.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 2102" status="3" xml:id="sect_TID_2102">
                <title>Quality Rating Identification</title>
                <para xml:id="para_6af9cb82-bd0b-4a42-8065-1f71c1b2f60b">This Template specifies the algorithm (and parameters) used to create a quality rating for an image or image set.</para>
                <para xml:id="para_b10fce35-d9ec-4500-b7ac-47eb2ea2ec4a">It is expected that the identified algorithm will create a consistent quality rating when analyzing a given image. If the algorithm allows change to its parameters that would alter the quality rating created, the specific parameters used should be specified.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f180e2c1-0a54-41b9-af40-23e8b886d77b">
                                <emphasis role="bold">Non-Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_3631b1a6-4e8a-4ba4-be84-71923c8c671e">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_a2a5421a-38eb-44a2-a423-bd4de80feeda">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 2102" rules="all" xml:id="table_TID_2102">
                    <caption>Quality Rating Identification</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e46f58e3-b0ff-4fbf-be39-dd89416dc2ea"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fcd8c2f3-7459-475e-8eaa-5eb0badebf8c">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2c5d32ac-986c-45d0-8f48-767b15a472b3">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_020ab870-625f-43f8-b88c-c249cd8743cd">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c4cd52c4-900a-4f23-b620-a399540d067c">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_61a22b47-f063-428f-9af2-106ecf626106">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d9ec4d18-e755-4543-a0f8-5b5131993d05">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dc4bda2c-0b78-4c1c-9d98-3ca3b392d707">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d23a98da-0285-4935-a61a-bbd099e153ed">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36682d5c-f73d-4342-a8cd-d685f9a11193">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b26c32f-26a9-47a1-a6a5-1a0ad0c92b07"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ea6198f-1a13-497b-b926-f44ea161b29c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_899a4fd2-a1ab-4dd4-80ab-ef95046ce13e">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38bddabe-0e8f-4656-8654-5a41daa5432a">EV <link linkend="DCM_111001" xrefstyle="select: nopage">(111001, DCM, "Algorithm Name")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_79d51837-8535-4cf4-b03b-0fcde4801b2f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e6772ce3-68f5-4a30-9d23-d3f87ebe047b">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7343541d-ea18-49ee-9c3d-4db255b598be"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_778bde44-6d7f-4f59-9897-7b98e76fa1b6"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6182b00b-b37f-4ed9-853b-4455757cf4f0">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c288c6ca-e669-4da3-bb98-ac7f9df3765b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e7cb220-c5ae-4683-bba8-b2720c23333f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0efa6c97-9684-4207-a3ae-7bbb02f4124f">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13a83bee-f30f-4aae-a9f6-27e99a39b690">EV <link linkend="DCM_111003" xrefstyle="select: nopage">(111003, DCM, "Algorithm Version")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_096e2da8-d6eb-4762-a5a1-0c219ecd012f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b2166d63-84c3-49fd-9889-1d5a4b6bb69b">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a82fca9e-da17-4195-8f94-58b8505158e6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_68419fca-bce5-4b46-b7a3-e8e21eff9457"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0bade7cf-da18-4d40-b475-4793f12bf470">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd2c0e8b-c29d-4715-986b-5559bbafe465"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a1baafd-ae46-4bda-bdbe-aa6891ea5136"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52798920-438a-468d-b0a8-9e04f561084a">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_833c0e2a-01f9-4360-8263-2bd64f01e654">EV <link linkend="DCM_122405" xrefstyle="select: nopage">(122405, DCM, "Algorithm Manufacturer")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9f36535f-d678-4ae5-ab0c-9868c09cbf52">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_040780b5-7301-46fc-beee-d513363bc21e">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a27ace80-3515-4096-b4ab-b49bea1ec2e6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cea21d0c-c5e9-40a3-9d54-b026fda7a642"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2b60d4c-2182-475f-a604-f9ecf4fc9c3d">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_422ff218-c25d-489c-8f1e-b87b2cb05ba6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_332f87eb-9444-4805-93f7-03ca1d388cfc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5574d304-6ba7-48b9-aaea-24f08eb2ed54">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc2ed4cb-5689-4ce2-bea1-5debc97271cf">EV <link linkend="DCM_111002" xrefstyle="select: nopage">(111002, DCM, "Algorithm Parameters")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_457b1598-2d2b-45e9-a687-ac048b64d068">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4f15d96e-46bb-4142-ad8e-c5d5bd6c90d7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_44f6b01c-0188-46dc-ba46-bce8e06e7e40"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bdb21028-e6b5-4e90-9d0e-b9b765dbcc7d"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 2120" status="3" xml:id="sect_TID_2120">
                <title>Ophthalmology Measurements Group</title>
                <para xml:id="para_a8a46c67-d591-468f-bb72-f9d2c89c7953">This Template is a proper subset of <xref linkend="sect_TID_1501" xrefstyle="select: labelnumber"/>, with some optional extensions, and may be processed by a receiving application in the same way. The parameters used in this Template are identical to those parameters as used in <xref linkend="sect_TID_1501" xrefstyle="select: labelnumber"/>. However, this Template is specialized for ophthalmology (finding site "Eye") , and makes mandatory a Content Item for each measuement or finding concept specified in the invoking Template in the Context Groups invoked for the $Measurement parameter (<xref linkend="sect_TID_1501" xrefstyle="select: labelnumber"/> has no mandatory content).</para>
                <table frame="box" label="TID 2120" rules="all" xml:id="table_TID_2120_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="left" colspan="1" rowspan="1">
                                <para xml:id="para_442c25a1-bd7f-4a2a-84c0-e7e2236b5d7e">Parameter Name</para>
                            </th>
                            <th align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0db81aaf-a06e-4cd0-93b2-bda0f2e40172">
                                    <emphasis role="bold">Parameter Usage</emphasis>
                                </para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ecd5bb3-7c22-4545-8aa5-e12954113021">$TargetSiteMod</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9b7f301-9bd0-4605-b922-443bde5a65f7">Value for Anatomic Location of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2d65e74f-7933-418c-b03d-d6a5ac8a08c9">$Method</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ebcf8700-83da-4a91-b889-c4a5eb10238f">Value for Measurement Method</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4686952-f05f-4dfa-9fcd-33602915621c">$Measurement</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4bf707b-f07b-4aef-8215-4b338e46a410">Coded term or Context Group for Concept Name of mandatory measurements</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_379a1c5c-6ee8-4d69-88a7-db2bc9216ce3">$OptMeasure</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dabf76e1-bcb3-4248-8424-8fc13a86ea6f">Coded term or Context Group for Concept Name of optional measurements</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd03075a-17fc-4b4b-bcd8-d83e73a7dd6c">$TableName</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d0e090c-c878-4254-93fb-248b4657d385">Coded term for Concept Name of a table of measurements</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_95f16474-877b-4b7c-8d66-ef18a6ef2be4">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_cae4abc3-b663-4a51-a119-cb00f3432bde">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_68624891-65ad-47b1-b273-bb1761074abc">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 2120" rules="all" xml:id="table_TID_2120">
                    <caption>Ophthalmology Measurements Group</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1"/>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_52d7b08c-79e4-49bc-8271-8cde08e5ba73">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_44af3296-8af1-45d1-8e12-ee9e0ee2308d">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_802c501a-5e7b-48ec-8847-fb5894ee4f5f">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d5372bc9-80d7-4816-8e62-2a3c1bb2a57f">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_98f8ed81-9e48-4ddb-ae51-90a0af9a5a29">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a5abcd57-e497-4caf-8f55-df9260e9c9bc">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e0d66ed4-e0ef-44c6-b871-905c856b40e1">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7e5f9560-5b29-418c-80a1-ed691044fbaa">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2649c6ab-238d-4b71-b9ec-d5e0bdd81fe5">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1570f8e3-4ed7-4e21-9ccf-42375748be74">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25e7097b-fc66-48ab-98b4-8b5ac7e6a768">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0c95f9d0-3215-4505-bc99-6fb68759957f">EV <link linkend="DCM_125007" xrefstyle="select: nopage">(125007, DCM, "Measurement Group")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b9ad711c-739f-4b20-9e8d-45c602a72aa2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ae29589-ab7a-41ad-98be-667ee87f6443">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e6e6d8c-e463-4c77-8403-b874add2ebd6">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec18f4b8-82e7-40b1-9314-0015b62be2e8">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_810350d5-fb03-4b46-abf2-870d8a1c9f6e">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d319d27c-22e6-40d1-8d81-4fb16299ac09">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9577ac6b-7b5d-4421-b93d-d9c492d51ce4">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_df299b65-939b-477c-8662-baeb86e4a0b7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ed17d74a-4827-4bb3-90ba-e6d42d18c488">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61b76667-68fa-4068-97a2-a00acfe87d72">EV <link xl:href="http://snomed.info/id/81745001" xl:show="new">(81745001, SCT, "Eye")</link>
</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6b39d31-1b71-44aa-9d92-a77c8ef28599">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2c14826-4eeb-4b72-958e-f02d33c3b066">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_463633b3-2ff3-4ab3-b563-7595e350bd9c">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_afec1d9f-25d7-4116-9c8c-791fdfc7d93b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1d8e51e-6b2a-4a8c-9ae0-266938354959">EV <link xl:href="http://snomed.info/id/272741003" xl:show="new">(272741003, SCT, "Laterality")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5bc693da-86e1-490b-a10c-3eaca4d41906">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e1b7c282-205c-4f70-a62c-cd9d4865c778">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_805c2a5c-5fb4-42e4-89f3-79a5fdeda9df">D<xref linkend="sect_CID_247" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_23e9015e-8acf-433e-af3f-89cc3ef5964d">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_797f4015-8678-4d40-907e-e7e2ea8f849b">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f873f09e-b048-462e-a13c-f5005e81f17a">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da9f4e67-2f9d-45ab-801c-bba4a0d5d26c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d7a49b5-fbcb-44f2-b1a0-710d2b6d79e6">EV <link xl:href="http://snomed.info/id/106233006" xl:show="new">(106233006, SCT, "Topographical modifier")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2da2b3f6-7665-4528-827b-1dcb2eb31fdb">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_02a624ed-2386-45df-a76c-cc092a5f2633">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b75564bf-ba5b-477a-b166-5099c2e53b53">IFF Template is invoked with a non-empty $TargetSiteMod parameter</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d763b46-42f6-4b28-a0be-cc1cf5c60ece">$TargetSiteMod</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4b08649-cf13-4f02-be01-dd37003b82ce">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb37ef5f-af27-4ec6-b85a-32e213c71d37">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73a12de2-5ad8-42be-b13e-de860ed59158">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da5d622f-2bdb-40c8-8663-accc1e616b77">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_44bf6a29-71d0-4b63-86ae-c02112687b53">EV <link xl:href="http://snomed.info/id/370129005" xl:show="new">(370129005, SCT, "Measurement Method")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6b17f0dd-9d01-4ab2-8636-81a4eb955af2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_83b5c180-59f0-45b7-b109-ddadbb80627d">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a3ebd8b-66ed-4838-a17b-f6622b3b1110">IFF Template is invoked with a non-empty $Method parameter</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a37edd57-c2ed-44ba-9c76-fa07f74b067e">$Method</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_670facfd-c97c-43fb-9abe-e83ae4f92e93">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7436f4d1-f949-4e7d-a679-1e9090fd8204">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd1e2138-406c-46d2-9cb9-c1eeafb55716">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9ea5c7c-21a3-4e64-91eb-6c84c999445e">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc5bd53e-c75b-40d6-8757-26bfcdf090b6">EV <link xl:href="http://snomed.info/id/418775008" xl:show="new">(418775008, SCT, "Finding Method")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a871e343-cf9c-4a08-8baa-e4df6de1a04b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_040dd120-8e46-4680-b9b1-8f36779893e4">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c74f5f41-68ef-4fd4-8058-2f10316b928f">IFF measurements made with ROI or sector grid positioned differently from prior analyses</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3509e33f-8d8f-4e59-9ace-915ea876dd81">EV <link linkend="DCM_131247" xrefstyle="select: nopage">(131247, DCM, "Repositioned ROI or grid")</link>
</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59f3cca8-5de4-41d4-a588-256d57dd2c9f">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e499dea5-259f-4deb-9167-c58f20b2d364">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98cdb4b4-da74-434f-84a1-49083ff8a83a">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_128ec48f-fb74-4930-b43c-4dee607f3c14">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_94fd7e0c-c936-434c-9110-c3edf778354c">D<xref linkend="sect_TID_4108" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ad7f98c7-a40b-4654-939a-5c44964d2fa5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_91a52d4b-fcd6-4d73-afd0-6db154c5d9a9">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7e3a590-19cd-451f-b7f0-a2c0d36ceb87">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_894b786f-29a3-4b71-b3f9-2f3185611a6c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aab0322b-4bfd-404b-887a-8791c9e4f34f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17888c0c-5452-4794-8e17-f3278d57ad5d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c350373-0df2-4985-8787-261dc096bb81">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c772de0-24d7-41c7-9624-fbbd15da20a7">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ef16a45b-fa57-4023-845c-7f72eea870f5">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb04f880-fca3-4556-a06b-58e22a12ff8c">IFF Template is invoked with a non-empty $Measurement parameter (see Content Item Description)</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_075807da-1053-4df0-9247-b18c5921c39a">$Measurement = $Measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98af7be9-dfd8-4421-b1b5-706d02fd627d">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d7d4e30-1671-4cb3-9467-65280e32d0f0">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_19f94549-7822-41e0-adc3-bf110e5dd961">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a85aa087-1407-4481-8fc7-6fa55edb25e3">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec0d015d-a561-47e9-bb67-497bcb38bfd0">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a21b4e5-ae19-43db-ba3f-b9dd2f0153c4">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4bb702d7-52c1-499a-b832-5a6ceb997495">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c99e1f30-8318-47a4-9095-506bfdb2f9b6">$Measurement = $OptMeasure</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c29122a2-b45d-4f94-a0da-1dcc65b7b751">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f51660f8-6599-4e0f-b44a-ad06e2047aaa">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a7d913d-e825-4ec4-aa74-0ca649a252b3">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52f008bc-2d52-4baa-a3d9-27c674b2fa10">TABLE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a481d965-6993-4f81-a840-3f0dc3a0aeea">$TableName</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9f7ce60c-7135-4bbe-bed3-edd37721b6e7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dcd31d4a-ade4-4e23-8be4-cb5d3b0bd78a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30b026ff-919b-438e-bb8d-d0a99f9489db">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9753cdda-db2e-456f-ac91-f4db3db9b9e7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5576b35-dca7-4625-8100-8f7d4e7a2296">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9fd4b4ea-d3ed-4009-a187-49923ef2380e">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_631c4c2c-c702-4320-a4de-817e7652b05f">EV <link linkend="DCM_121112" xrefstyle="select: nopage">(121112, DCM, "Source of Measurement")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_820c8b4e-70d7-48bc-977b-ea355adf71a0">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1e84ec2b-1d08-440d-ba29-7e8df390d137">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f623246b-cd40-466f-a5bf-d54be3238d22">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6e9b155-9c27-4ce6-a34b-681162fae5e3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6e80959-267d-4333-8dc5-01bfc949ac1e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf604597-5c8c-4470-a4a2-3e3d592987ab">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6ef0dc3-fd95-4504-a9bd-f3255f01f538">EV <link linkend="DCM_111694" xrefstyle="select: nopage">(111694, DCM, "Image Set Quality Rating")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e66f15b5-785b-4fb6-83a9-9690fc418078">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cfb0fc01-22da-4313-8499-35f6ee24bbc9">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72920329-91bd-4f64-ac54-5529a2ee3ef3">XOR Row 13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_345fda9b-4be9-4d53-a172-18c6da18dcce">UNITS = EV ({0:100}, UCUM, "range:0:100")</para>
                                <para xml:id="para_5233afb3-29ab-4fd9-93a7-f2d6eddc0c87">Value = 0 - 100</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d575f939-b722-4542-b343-53fb9e2ee9d7">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_293fea68-a4a5-4da0-aab3-a5bdf41b1abe">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24ab42ff-2ce2-4900-8987-d87af3e42c40">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_07853f17-fd8c-40f0-b39f-7bed0ae96a7d">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3f5a22f-ddfd-429c-988f-875176f17adf">EV <link linkend="DCM_111101" xrefstyle="select: nopage">(111101, DCM, "Image Quality")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6794655a-e3d8-43d6-a9d2-86a73e746853">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb3d0ab3-88b4-47ab-9d55-1d7b63063c97">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f4d58ea-23fb-4e08-9177-f03acb39e458">XOR Row 12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_183cc411-bd4a-4ef2-b94f-a072919081f2">B<xref linkend="sect_CID_3114" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4562c814-b45f-4872-ba10-724af2c907e3">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87164a8c-dc61-4612-9977-aedb2f167f60">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1c079e2-04db-426f-8134-ea34b36cadd7">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c7f98a1-3f2a-4f46-a968-879408592df8">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f729698-2efe-45f2-9ff4-677850ea25be">EV <link linkend="DCM_130401" xrefstyle="select: nopage">(130401, DCM, "Visual explanation")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0207088f-af47-418d-9a1b-dd4be655b9ad">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b2111ed3-e5e8-4a91-9279-560e93059a90">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f390a04b-b779-41d2-a659-644758658ae7">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b726e03-ee39-448a-8d8b-a99e7774322b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_872d381b-279e-4d81-82df-7e56f8e92aa0">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c2014a3-5086-4d0d-9b4f-90cef83453be">COMPOSITE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16da7cea-6365-4074-8c4a-85c167b4e83c">EV <link linkend="DCM_130401" xrefstyle="select: nopage">(130401, DCM, "Visual explanation")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_024ce748-7277-40ce-b988-dc19b0ce050e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dbc6126b-0c16-4660-b8d6-241026ef008f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b43cbbec-aed4-4f5f-b967-4d997e462247">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4663ca4a-ed91-4061-a202-1290490a8aa8">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce5e2f8e-7ab1-4f40-a4bf-b2de33b7eccb">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8611375-767b-4bec-88e2-9f14d8c155ba">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57326d4d-8263-44e1-93c6-ae7e02a6b9df">EV <link linkend="DCM_121106" xrefstyle="select: nopage">(121106, DCM, "Comment")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4652a9f3-8513-4a4b-ae15-1a03e8b1f9fb">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_06130079-8fa2-4752-aa08-ecddccda07a8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_6d758cbc-7ac1-4c5c-a6d3-8e09815e1986">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c46522a0-414b-4234-88a7-b0f1a45dea5e">Row 8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c5719a5-6ebb-469a-b178-5975af75fe2c">Mandatory numeric findings of the measurement group.</para>
                                <para xml:id="para_82ddb494-996d-4e99-85e4-960cb51ee5f7">Each Concept specified in the Value Set Constraints (i.e., as specified in the invoking Template $Measurement parameter) shall be encoded in a NUM Content Item. Thus if there are eight concepts in the specified Context Group, eight NUM Content Items in accordance with <xref linkend="sect_TID_300" xrefstyle="select: labelnumber"/> will be present. Note that the NUM Content Item allows an absent value with an associated reason code per <xref linkend="sect_CID_42" xrefstyle="select: labelnumber"/>, e.g., <link linkend="DCM_114007" xrefstyle="select: nopage">(114007, DCM, "Measurement not attempted")</link>.</para>
                                <para xml:id="para_1b675cb5-cca6-45e9-a487-13966250601c">
<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle"/> defines an optional capability to specify properties of a measurement via <xref linkend="sect_TID_310" xrefstyle="select: labelnumber quotedtitle"/>. <xref linkend="sect_TID_310" xrefstyle="select: labelnumber"/> supports properties such as normality, statistical properties (through subsidiary <xref linkend="sect_TID_311" xrefstyle="select: labelnumber"/>), normal ranges (subsidiary <xref linkend="sect_TID_312" xrefstyle="select: labelnumber"/>) , level of significance and more. Normality flags are highly useful and commonly provided by implementations.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bbaf2171-c3e6-443e-b8b4-29d5634eb907">Row 9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eaa55f05-165c-4cfa-96ef-dfeb2e2fa3ab">Optional numeric measurements of the measurement group.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a3aa173-d176-4516-a47a-e470481c65fd">Row 10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8fa75ad-4648-427d-b7cb-250fc2380af2">Optional table of numeric measurements of the measurement group.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48fa31bf-187d-46bb-b235-54218644e0ee">Row 11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3b09394-6657-4f48-921c-e1466199559e">Reference to the original image(s) , e.g., Ophthalmic Tomography, that provided the data analyzed to produce the measurements in this group.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_41c4fe60-3a39-4776-ab67-da8cb74b0a92">Rows 12, 13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97533a96-8c02-4ae6-a4da-9b165f937bec">A numeric (row 12) or categorical (row 13) rating of the quality of the source images for the purpose of producing the measurements in this group.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3018d59a-ab71-48eb-bdd6-27635594656d">Rows 14, 15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58ca3e96-8fa9-4d06-aa1b-cbfce56decdc">May be a reference to a Secondary Capture Image (row 14) or Encapsulated PDF (row 15) rendering of the set of measurements and findings encoded in this Measurement Group, and possibly additional data.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 2121" status="3" xml:id="sect_TID_2121">
                <title>Visual Field Key Measurements</title>

                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_872eaf93-4cbf-48e4-97ef-06f35cd99d25">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_c1599549-e100-40c7-9994-c2787f3b17a8">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_8e1ced3a-2ed9-407f-b80c-0bd940534ba0">
                                <emphasis role="bold">Yes</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 2121" rules="all" xml:id="table_TID_2121">
                    <caption>Visual Field Key Measurements</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1"/>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a1393745-c2c1-4180-bcc2-f628765f7dc2">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc6edb4c-b5ae-418c-a6a1-67d0ed5097c4">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a9e9f770-21e4-43d9-bd47-94afd9a50303">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c01b9813-3501-4279-bcaa-c49f304c05b0">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cfeb8651-ab5d-45e8-aa33-7e3f46612a82">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eca0dbd7-9b85-43a9-be03-8767603bf1f4">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f472d75e-d919-456b-aca4-1bb935090aee">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d452e093-534a-4f0c-a316-361992ebf5ee">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_805f64c4-deb0-4a11-8964-6129b819f3c1">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_64003f3b-b8bb-4b54-a6ac-d657edc92a21">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6aea5402-5fbb-47a4-a956-0df3534d70d0">EV <link linkend="DCM_131240" xrefstyle="select: nopage">(131240, DCM, "Visual Field Key Measurements")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_002bb04b-77bf-48af-9a1c-c2c2808eb66a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bdda28bc-f06a-49c7-a2c6-339abd010c8e">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b36ba2ed-b4cd-49a7-8e77-6a41eb75d7bb">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d82db5d3-c7fa-446c-bb94-5dc6a7a28ecd">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e23d32ba-dd5b-4f5b-8794-99b1baae8cb2">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a0e13e8-8a8c-4dda-b0de-5a5f7ab073fd">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2dd8ee07-c1e6-450e-ae7a-d344178e9496">D<xref linkend="sect_TID_1204" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_721d5c10-89b2-4a2d-ab23-b8de150ebacd">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c5647d98-b3c2-494a-84c9-ddda00b0ca46">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4339550a-a026-4971-8843-c844ac155724">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa98e73f-06c5-491c-ac5e-535b5af7dccb">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4bb9346f-4745-4044-a3b9-c80b269c0dad">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6c5001d-42bf-45d6-8b86-52335442c235">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97393dee-bb97-448f-99f7-2fa6286bc9bf">D<xref linkend="sect_TID_1002" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c980c98f-593c-4aaf-b138-b310d3ef7df5">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0d486748-125b-4eaa-b193-abb704441794">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_276fbc61-0812-4808-8adb-bc12b501aa52">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc34b623-3215-4d58-839f-d2e6a459a9cc">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a79c948-dc61-4ff4-ae89-57345aebae25">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_679efef4-b5ef-410e-97f1-2dd90e86d4dc">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca64dd24-afe7-462b-bbcd-1f9580d05ed9">D<xref linkend="sect_TID_4019" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6faa620d-253e-49a7-bb91-070e5c319147">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ee763a5c-658d-4375-9dbe-a1829d9c70fb">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70136590-9aac-4323-9062-365784387175">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9749dfe8-65d0-4676-b993-5b310a32ef23">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_41cb4ccd-1e0e-4165-855e-dc8d9ad5a92e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8133c446-4407-4a3d-9d8f-6137fd65818c">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa8fcf99-8a48-4aa4-ac60-898a2b231ed6">EV <link linkend="DCM_125007" xrefstyle="select: nopage">(125007, DCM, "Measurement Group")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e0c3773d-ff3d-4bf0-b6bb-9d208b552538">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0251c556-7057-4c1d-8b30-14f01e47071f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79aab650-7f16-448c-b48a-7256f75d423f">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_edfb7588-bb13-496e-b6cd-9819be12348f">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93bd352b-77e7-4a3f-826e-16ce2adcf67d">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_341cd5e1-99ad-4681-aa84-eb69d6b0c51a">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_34b37dbb-f979-4a6d-ac27-bc67dfe63577">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6dec6cae-40b4-4995-87fd-1989ffae84f1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_625a0185-06b6-4d1e-bc6a-3bc3db6b5269">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06c2dbfd-792a-4059-aad4-847b916a76bb">EV <link xl:href="http://snomed.info/id/81745001" xl:show="new">(81745001, SCT, "Eye")</link>
</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37d41164-29e3-4f93-892c-0689126b9513">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_18009d95-2145-481b-b96b-3e60000adc10">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b12b2fcd-5c47-45d8-ba60-4bd1c9e1a54d">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_514ce438-96c4-4ba6-8fa1-886e96fe8fec">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a52ee71-1e76-4a01-bccb-f13ad41d9051">EV <link xl:href="http://snomed.info/id/272741003" xl:show="new">(272741003, SCT, "Laterality")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_834c443e-5d21-4786-9e4f-eb29f3f4d8cb">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_912c6af7-9c54-421a-bc80-216ff2ef61b6">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5f56f98-b938-4b78-a12c-5514ce8e276d">D<xref linkend="sect_CID_247" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75256b00-f063-4d04-8937-bb990c89925f">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c855f61b-453a-4bfb-8848-b77502013622">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1dd4d5f9-d4fe-4932-b33f-bc03fda7d2c3">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b140bed-564c-4fb3-ac4d-a73802945f24">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_022fb3a7-cd90-4e0b-ae63-e09b7c27d95e">EV <link xl:href="http://snomed.info/id/370129005" xl:show="new">(370129005, SCT, "Measurement Method")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d2648914-3903-4c13-a7fd-9d06ffdbf12f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_53f9ec4d-a36f-408c-8bc0-c9ecea8a6def">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3103a057-032a-4580-8e73-ae2dff3ef0ae">D<xref linkend="sect_CID_4250" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_573cc560-2284-49df-b2a4-8f0da25f650e">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_997e22dd-0ae3-460b-8429-bc7a99f6043c">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_730c1f66-67dc-4ad9-97a3-ac3976a367f0">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da40ec70-ffcb-416f-baed-ddb1c6f2db44">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_583f0ba9-3a34-4d10-8bad-b7478bff1997">EV <link xl:href="http://snomed.info/id/246501002" xl:show="new">(246501002, SCT, "Technique")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_407aea80-cf0c-4f90-a350-4909a7f9cc08">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9a0ba4e5-7dd6-4df2-9908-325196ae3da9">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5c244de-33b2-416b-9766-7f0913b41241">D<xref linkend="sect_CID_4251" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73113e07-552a-4947-8300-e660df7bda8c">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c8a447d-22f0-42ae-bca9-cf62ff56e9bb">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a14c408-06ae-4a2e-9b02-215ef45beeb6">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_826fa976-272c-41f3-9c2b-37cb0fd911b2">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed01567f-3b52-4daf-ba84-dfcd44b6794b">D<xref linkend="sect_TID_4108" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b445f151-631d-4c6a-ac2a-770a4da98165">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_42cf5964-6df4-4520-b0c9-84be853ee78d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e48ece0b-699b-47b6-a671-4267f1ce09a8">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9faa3f08-4292-4f29-8f9f-eb8df79d135b">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59f77f8f-4754-4e34-9902-9d57e4f13419">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b34f3d52-02fc-402c-ae7b-744558268bdb">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f08b4ba-85fe-4228-8c2c-0a0733a628cd">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cd081258-3a0e-4cc1-ac99-53abef0c8162">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_af86bcae-f725-418e-b845-f5b4ae34f442">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1995df6-be6c-45da-b99e-99130660ed6e">$Measurement = EV <link linkend="DCM_131248" xrefstyle="select: nopage">(131248, DCM, "Visual Field Global Deviation from Normal")</link>
</para>
                                <para xml:id="para_74e39be1-da8f-40fc-a610-749d711b72a2">$Units = EV (dB, UCUM, "dB")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e031f25-cded-49d5-be6e-6f45a82fca60">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f1f9bad-c563-4d39-b862-935e4742db3e">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09618246-1e73-438d-aa13-88e5d19ef4d5">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c71aec9-17ce-4e8d-9abb-3d79ec4a5790">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b3e79e5-0ca7-44c2-bad9-f35e4cbf1fec">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_899b4f51-a455-4272-ba28-dfccab2fd668">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_52c13cec-d1ae-489a-b36a-2c96b06e9514">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_538de99a-c76b-43ed-a619-7a1046c6d176">$Measurement = EV <link linkend="DCM_131249" xrefstyle="select: nopage">(131249, DCM, "Visual Field Localized Deviation From Normal")</link>
</para>
                                <para xml:id="para_593b4dd8-35dc-489d-a895-e02b3754a308">$Units = EV (dB, UCUM, "dB")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e88ce01-d6de-48a4-8713-2da30b6c2b76">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13283593-ca85-4106-9109-4fc8889ae36b">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b9631101-55a3-4d94-afcc-b938691b27a3">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ff42f9a-7d44-4c4e-a455-1ba79cb42224">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_676b9987-afa7-4803-9f26-d24a84a7f715">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2ae6834b-d077-480c-8429-709fdbdfc6a6">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f5c701fc-a42b-4e73-a839-ca6814efcea5">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86203099-c1cb-497f-aaab-ca54214c0f58">$Measurement = B<xref linkend="sect_CID_4280" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1419a9db-d070-4993-80b7-fe59605427ff">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_094ed008-59a0-46fc-a0d5-710b4b53705d">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3847f737-60b7-49c0-9766-9b31123546a1">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb7b53dc-4da8-499a-947a-1fdf4b420ea7">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b1e8a0e-23b5-4af2-8bf5-1ee49ffe7327">D<xref linkend="sect_TID_314" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3f49fad3-0cd2-4e9c-a758-1ea1f71cbc03">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_36c06c03-96a0-49da-8dcf-5a7b335c3c44">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_20202007-8bc1-4336-9f1f-bd7f8ba974f4">IF Row 15 not present</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b91f3e45-c0c6-473f-837d-df7bac70e5ff">$Measurement = EV <link linkend="DCM_131250" xrefstyle="select: nopage">(131250, DCM, "Fixation false positive ratio")</link>
</para>
                                <para xml:id="para_ecbba04a-9c51-4b0c-bdbc-cc4e8303fe03">$NumUnits = EV ({false positives}, UCUM, "false positives")</para>
                                <para xml:id="para_9311fc87-30a3-4888-9955-546881c755d7">$DenomUnits = EV ({trials}, UCUM, "trials")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_41488f83-2057-410e-9ca3-bf7eeee56f31">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38131ecb-7467-4c0f-8467-7e0fd329020c">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_530f8818-c4a7-401e-a0d2-ada1397806d1">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ceed10c2-d50b-4539-b698-c6c38a8bfcc2">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fee3121e-e4d2-41d0-88d9-ca2dd549a280">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ecd1fb8f-d455-439e-8509-6e8518d21e2b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_efb45220-525c-47c6-9e3c-88f28c4d14b3">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7a17964-038b-4efc-bcc7-e0417ad165a9">IF Row 14 not present</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5dce32e-f362-433e-b58f-6d1e5085c37d">$Measurement = EV <link linkend="DCM_131251" xrefstyle="select: nopage">(131251, DCM, "Fixation false positive percent")</link>
</para>
                                <para xml:id="para_66bc3943-4cc9-402b-85fe-fc889e622f96">$Units = EV (%, UCUM, "%")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c54f1a1f-3c10-4f2a-9a2a-beddaa5f03c7">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59f9b523-b5b7-4fb4-a710-a39f5fc1239a">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4f56357-4812-473c-a9a8-ced416d56864">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0dda27ce-2de3-4eba-be51-37eb669f3705">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_452ae8c3-7b3a-4ab1-b459-7c5b9c44c592">D<xref linkend="sect_TID_314" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a36520ab-2c9f-4fba-b5c2-d090b0cba858">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c89c74f8-3223-42c5-85bc-74126bdce348">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c7b5af7-dcf4-46ed-ac1b-93b1e17a09ba">IF Row 17 not present</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_740f2db1-6fdf-4298-b71c-d45575401654">$Measurement = EV <link linkend="DCM_131252" xrefstyle="select: nopage">(131252, DCM, "Fixation false negative ratio")</link>
</para>
                                <para xml:id="para_8aee738e-0736-4155-97ef-9716fc7d9b43">$NumUnits = EV ({false negatives}, UCUM, "false negatives")</para>
                                <para xml:id="para_0f167062-d214-4a8c-87f8-d28a615bfcd3">$DenomUnits = EV ({trials}, UCUM, "trials")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f54833f4-4e6f-4b7b-948a-85a7574cdf05">17</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3d1cad8-ccdf-4873-b129-754141934cf4">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27af87f5-675b-42ce-89d7-2da9855ec062">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a554578-ab98-4e47-bc93-278ecaf8ec10">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ebc0a35e-08d3-4146-ab4b-072871057bed">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_27807cea-7658-4094-8307-1e961b2f2a3c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_78c6f4e3-a937-47cb-913b-b240e7a70c27">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd8b93d9-5dd4-4ebe-a95e-3490f2c317d0">IF Row 16 not present</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af131fd5-f0fc-4350-af00-9fedbe367790">$Measurement = EV <link linkend="DCM_131253" xrefstyle="select: nopage">(131253, DCM, "Fixation false negative percent")</link>
</para>
                                <para xml:id="para_91f6f118-4887-42f3-8604-812b4e756960">$Units = EV (%, UCUM, "%")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a2670ad-2f80-4da4-91f5-049009620e64">18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ab762ca-7cfc-4522-8107-b4aedc34f039">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_858a5969-0b18-4f6d-b226-4a863cec3d69">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_094f050f-c1ba-4eb3-87d8-45b30bfd3c51">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26a32e77-de85-42df-9a9e-06ef226062d4">D<xref linkend="sect_TID_314" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_40153c54-9871-459d-a7ca-65db491fa987">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9018511f-d8a5-4b93-acaf-80510fc7c459">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d6f14f5d-c744-4a05-ab35-0bdcef6c86a9">$Measurement = EV <link linkend="DCM_131254" xrefstyle="select: nopage">(131254, DCM, "Fixation losses ratio")</link>
</para>
                                <para xml:id="para_f6d0bba2-b07f-415b-ae6e-50213e645430">$NumUnits = EV ({fixation losses}, UCUM, "fixation losses")</para>
                                <para xml:id="para_c0c1fcaa-2b22-4936-9f67-9286d7fd32aa">$DenomUnits = EV ({trials}, UCUM, "trials")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c21d787-c44f-47e9-bc47-2ba1bbe7398c">19</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4309d5f9-9c10-4faf-9a64-c7eaa8e77f07">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d515ce16-4745-4108-8f03-0962aa78ab91">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d15cea0c-05c8-4c8d-add7-e66b5619111b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39b56f8a-7299-4c88-9e0f-a6fee3dbe700">EV <link linkend="DCM_111855" xrefstyle="select: nopage">(111855, DCM, "Glaucoma Hemifield Test Analysis")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_321eaf9d-666f-4d40-a5e2-f0eaf35bfd17">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f2d5d9cd-c46c-4bea-a342-2c21dc1b596e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f3dd125-6306-4011-ba74-9983452fab70">D<xref linkend="sect_CID_4254" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b8f53fc6-8b53-46fe-b7ea-aae02a270603">20</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d4320a2-3596-433c-805a-2923ce1990f5">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_379ecbc3-2675-431b-a8e5-2650c5c600df">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0710124-43e7-475b-8649-8b29b497ffc3">COMPOSITE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff9a1b27-6c86-450b-9b48-6c46149d70c2">EV <link linkend="DCM_121112" xrefstyle="select: nopage">(121112, DCM, "Source of Measurement")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_99277842-2249-4c27-bd21-d5970574fa68">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ebdd8cf3-1e9a-44d2-a7dc-b129861d74bb">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b72ae332-d287-48fb-a0cb-f1ffacdca2a5">21</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fefe923c-2269-4a05-94b9-95d3d96cc1e0">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0c7c684d-8623-4e5d-b2a5-80e278e148ea">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_491a56ef-7241-4263-8e26-da967a0cf65a">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7fea740c-1823-4541-8b72-77c8d5245575">EV <link linkend="DCM_130401" xrefstyle="select: nopage">(130401, DCM, "Visual explanation")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ada303b7-67f0-4360-b490-32ca40a66ea5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_61ae6569-72f9-4890-917e-a176089b15d9">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_47378004-db46-4374-9663-46f75a2def21">22</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4fcae168-14c8-4187-8142-a0198fe2b03f">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_280061f3-0b7a-42b7-a4c7-47c9b4189874">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee1be02b-592e-476f-a623-701df7edc872">COMPOSITE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85aa065d-0c02-4730-b446-b23b97e608ac">EV <link linkend="DCM_130401" xrefstyle="select: nopage">(130401, DCM, "Visual explanation")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_66ebb96b-a5df-49ff-b4e9-04677a7783ba">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_65adf2e7-ed15-49a3-9b27-3cf38d554312">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5dcce3e7-2de1-4e9e-ad92-0fe4d9f02d54">23</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b5f2486-f512-46de-a9ec-df1216a34ad6">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3416c22-6e4a-4169-95d6-66e3a27f1d2a">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52585e71-f45e-4bdb-af4c-32f1d3499fdb">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc8c629c-dbbf-4e00-a22a-20e22f3ea46e">EV <link linkend="DCM_121106" xrefstyle="select: nopage">(121106, DCM, "Comment")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_72dd6f01-f556-4d0d-ba51-9b93253fa052">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ff705609-6d90-488d-bb8f-44bed74e08e9">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_61b36a5d-c329-47dc-ac6f-44c8b667f0a8">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b362c10-6399-4474-b9d4-3b8476f69e17">Row 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04b238ae-4c72-4d74-a2a3-35683fe7e654">For example, the Measurement Group CONTAINER may be instantiated once for each eye, or multiple times for a trend series for a single eye.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_609fc466-c05b-4e18-acd7-d570a60e4988">Row 20</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f849afa-1e87-41ac-a1a8-846ea01a995d">May be a reference to an Ophthalmic Visual Field Static Perimetry Measurements SOP Instance.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9569ac6b-59da-4dd9-b4a4-6d11431c24a4">Rows 21, 22</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96233d24-ad56-4773-812f-fab16d3f818f">May be a reference to a Secondary Capture Image (row 21) or Encapsulated PDF (row 22) rendering of the set of measurements and findings encoded in this Measurement Group, and possibly additional data.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 2122" status="3" xml:id="sect_TID_2122">
                <title>Optic Disc Key Measurements</title>

                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_b1d94859-7429-41f3-99c5-c1347a423fe2">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_403fc043-60d2-4302-b984-1f81d3f5d38f">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_9681ac7f-fcde-45ef-8532-20e2607d7f00">
                                <emphasis role="bold">Yes</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 2122" rules="all" xml:id="table_TID_2122">
                    <caption>Optic Disc Key Measurements</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1"/>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_df9e246b-5137-4389-9806-4c6de3b06931">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f67af7ba-86ac-42dc-af79-d19c15409eb5">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_58324790-79b9-473c-a0cc-fe86d6d769c3">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_723fb3cd-79ed-4d53-8517-288ff194cba6">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3fa80040-dbd8-41f5-9078-a74fd780fad5">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_11b0aa74-b5ba-4f32-b44f-d35b4f78967b">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3991bf80-9cfd-45e3-b7a0-571b4b1ccb08">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d6a69b5f-28e0-4ec1-9040-560e8d8c8e74">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51a630e2-ac11-4241-890f-a1d23f63f703">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b8114406-da85-4a93-a2be-afbcf3ff4d9d">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_45906075-ebd7-40c0-8776-dd5e9f5d073b">EV <link linkend="DCM_131241" xrefstyle="select: nopage">(131241, DCM, "Optic Disc Key Measurements")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_49da4d8a-7520-4b06-a44e-0821b97b3917">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_18d79385-b975-41c7-b45f-7232fafb7a30">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99637621-f44d-44eb-9bbe-5a0ddb0f342b">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d23e1689-07df-4508-83c0-93ddb8d2fdca">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b223adf9-79f1-4469-a461-63a843c1d716">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a5da7dd-a764-434e-855c-255f4e60de3c">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ace9211-8c06-4154-ac70-7e762f65c391">D<xref linkend="sect_TID_1204" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_75c26c47-9387-456b-b3ad-d92b6511e351">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d3a10325-2a53-453f-aee2-3d892b96437f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_32450dfb-8ca3-481e-9592-ba8ae83bd830">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8baac5bb-c265-46f6-9991-e911c4db4c2c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30b20fb1-fe69-41be-859e-7472f173ba12">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df35bbe5-03b2-4a10-85f1-663e015b6b2d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6a88288-d9d8-4008-8ee3-f1ce6d7d6f33">D<xref linkend="sect_TID_1002" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_56d06aef-e591-434c-a198-01aa5b54e650">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b0322143-42be-44f0-8dd8-87be07dbcee5">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05a82303-0aa8-45a3-9b09-b81050aa7ced">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38d80e26-58b4-4b26-9559-25b23b90cc32">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f7e83284-8121-444a-945f-95bc0e350a09">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_484ccc9a-2ce1-4a9b-8632-93462c46dde6">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f95dbf5-5274-4e25-9bdd-d8bec46f0990">D<xref linkend="sect_TID_4019" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bfa9233a-8b9d-4584-b2dc-c3e0ca1aa697">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fde25609-92e8-4a37-8c5c-09bb8224863d">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86fa4dcb-f569-47b5-a9cd-112495b77cc4">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b8ac760-9087-4f07-ae5f-6a970a7fa219">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8535cf8c-1f4a-4aef-a1ce-6e1440b8320d">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c45e35f0-2d91-4fb8-a435-85b755a4c31a">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af35afe6-5ae9-4655-b391-bfe986d15e0c">D<xref linkend="sect_TID_2120" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b491503b-ed23-4979-a213-7d3ccd33357c">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cb25a7f0-9088-4f48-b31f-d35130b2fbe4">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a9a2bfc-ddb5-43e4-b947-344b07fca173">$Measurement = D<xref linkend="sect_CID_4281" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_8b7dae51-6b4f-4f35-8bbd-f06177a23ed1">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce0d9ab3-7262-4146-96c0-82939824334d">Row 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9de5cb75-da7e-4968-b066-554b2eb56604">For example, <xref linkend="sect_TID_2120" xrefstyle="select: labelnumber"/> may be invoked once for each eye, or multiple times for a trend series for a single eye.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 2123" status="3" xml:id="sect_TID_2123">
                <title>Circumpapillary Retinal Nerve Fiber Layer Key Measurements</title>

                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_3ac309a8-1a01-434e-9463-bab72c6809e4">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_01f4e96b-5467-47de-8321-f697f3c739c7">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_1b190bea-7b1e-4b4c-8222-5db968ad7350">
                                <emphasis role="bold">Yes</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 2123" rules="all" xml:id="table_TID_2123">
                    <caption>Circumpapillary Retinal Nerve Fiber Layer Key Measurements</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1"/>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_461ebaf2-e362-41df-a3c9-bc65ebb99bc3">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7750f488-4ac2-4562-977d-b7d5edf88595">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7600dcb0-ce5a-48bb-a323-8032d60ca357">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0214405d-bdf3-41e8-aa6b-20ebfae901d7">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4b2f6c67-97ed-4eb9-9203-ab42b0e6a818">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0af1c56b-6ef1-45f1-840b-a87542b3739e">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_073b4d44-77db-4362-8045-877081d315c2">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_36f05959-580e-414a-9baa-42b1310b8e00">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_45954bbb-552c-43a5-97c1-0217cd9a31c0">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42be7205-0761-4a0d-8d55-421b62752c85">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cdb4bfe9-ad65-4c89-bde9-cd656acc20dd">EV <link linkend="DCM_131242" xrefstyle="select: nopage">(131242, DCM, "Circumpapillary Retinal Nerve Fiber Layer Key Measurements")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c1b56000-563e-4ea6-9bae-3c09b04ac6b8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f05ac758-bc8a-46de-b8d0-2d52ad4df9b1">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc5ac5a0-6d97-47ab-8552-cac81eced7f6">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6367b5fd-786b-4355-ade8-770dc29836ba">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39615b1d-01ad-424b-be7e-c735ea2ad4b0">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3fe7b59a-d8af-4849-82d9-73a5be79c15b">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0c4343a-49f5-4c1c-8286-088777c16db2">D<xref linkend="sect_TID_1204" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2cdf8bea-a9ff-421a-8276-7842cbe3249b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6a99f2e7-35d2-4beb-a3bd-ec4865a588ca">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee4bea47-196c-49a8-bd5b-41bddb472849">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f7b7894-adb4-4629-9dbb-8d8bceb85c43">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82e7910c-fa4f-4c76-8f53-957ff8cfb899">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22737b09-d42f-4db9-b8c2-12965ef6392d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_121b8388-a7a2-40b0-893b-8082051aa7ee">D<xref linkend="sect_TID_1002" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0525f6dd-dd82-4254-b900-7594328ec714">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bcd00140-25bb-4ffc-a15a-1cc5e525a1e7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b81e32a-8569-4caa-8163-855b26077c33">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a66a1d26-210f-4c91-8d7e-9a0a8fc0c104">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5d267a8-4820-409e-bb9d-ed53945efed1">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1860c0d1-06cd-4534-a979-7166e1e234a2">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6868f4a-a040-4549-bed9-f89d2af40a27">D<xref linkend="sect_TID_4019" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_03052162-d4d8-4310-af33-d02c0c19b947">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_daff50ba-cd7a-412d-bc44-aad6ff5c4c6f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98333d58-d107-4ddb-9ac2-116d499c6b26">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a81865ba-d6d3-428c-a099-0c7d851b292e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5e1b45a-8f3b-4769-8a0e-dc8c268d1207">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a89c8087-5cdb-4e12-8fee-e0127e5b38bc">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4beb09a3-b458-466e-aae0-149450d258ea">D<xref linkend="sect_TID_2120" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a715e5f0-ec0d-4d5d-a81b-d63151f0027c">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_64d0af99-e8cb-46d7-ad43-4fec048689eb">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c86e3c03-87c2-41e1-b552-5168edaf9016">$Method = D<xref linkend="sect_CID_4282" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                                <para xml:id="para_8ee1439d-a4f7-49b3-a3df-d4530c70dcb8">$Measurement = EV <link linkend="DCM_131274" xrefstyle="select: nopage">(131274, DCM, "Retinal ROI width")</link>
</para>
                                <para xml:id="para_71811022-77de-440b-8955-ad4eab76db3c">$OptMeasurement = D<xref linkend="sect_CID_4283" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_778aaf6d-995a-4ac6-aa3e-3a9371d2cf30">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_372f4294-6c78-45ac-bca6-cd9a1f72c951">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba828011-20b5-4dab-bdd5-b4920717624a">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21e7511e-4900-4464-adac-bcedd3210b10">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36674aa6-11d7-49a5-85d2-ddf4bdf021eb">D<xref linkend="sect_TID_2120" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e4537f46-a34a-45b9-8d0e-bcfe7a74d051">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ef3006d2-e3a1-4fb6-8fd9-4d04907cd934">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc3f12fc-3ca9-4c06-b6fe-c297f3bfe90c">$Method = EV <link linkend="DCM_131308" xrefstyle="select: nopage">(131308, DCM, "RNFL Clockface Method")</link>
</para>
                                <para xml:id="para_ebf6379e-b541-49e6-9b6c-61d9bf7e0442">$Measurement = D<xref linkend="sect_CID_4284" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_932adf64-59ea-426c-8ada-9ebb8c645a26">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c2557e57-c87e-4564-b500-6ba53c4f50bd">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6b209a4-5484-4505-a55e-e146746f5173">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4fa5eac-1894-494b-91e9-af2d327f639a">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b549d6be-b6bc-49a8-8e11-f2d356af6f47">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b758a815-3b49-48f7-86ff-67adf93b8e63">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5404b14d-10dd-4ee4-b823-362a6cc36c24">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ba63680-48a5-43ae-8ab5-eac1d77a716b">IFF RNFL thickness measurements made on both eyes</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5501427a-60bb-4440-80c2-682d7d4c0999">$Measurement = EV <link linkend="DCM_131273" xrefstyle="select: nopage">(131273, DCM, "Retinal nerve fiber layer symmetry")</link>
</para>
                                <para xml:id="para_0b8d2755-0309-4771-b5d9-4b83a1bf23c7">$Units =(%, UCUM, "%")</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_8fe1f213-60a0-473e-a5ef-781d6dcf69cc">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42ba416c-bfe6-4faf-8107-148782c25764">Row 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_90f85395-eb56-4c24-a9a8-4eddd52ca846">For example, <xref linkend="sect_TID_2120" xrefstyle="select: labelnumber"/> may be invoked once for each eye, or multiple times for a trend series for a single eye.</para>
                                <para xml:id="para_3dd11ff2-8b72-4d2b-9c47-56c2f0dc53f5">Applications also use various approaches to identifying different sectors of the retina when measuring the RNFL thickness. The sector definition used is specified by a concept from <xref linkend="sect_CID_4282" xrefstyle="select: labelnumber quotedtitle nopage"/>. Measurements that match the sector names defined by the method may be selected from <xref linkend="sect_CID_4283" xrefstyle="select: labelnumber quotedtitle nopage"/> to be included in the key measurements.</para>
                                <para xml:id="para_de9b0929-ce74-44d0-aa49-e3ceddaf0f86">Receiving applications are cautioned about comparing or aggregating measurements from measurement groups with different ROI areas or sector methods.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 2124" status="3" xml:id="sect_TID_2124">
                <title>Macular Thickness Key Measurements</title>

                <para xml:id="para_9518b50f-5354-475a-84c8-608c393464a8">The macular grid used for the measurements of this template is based upon the grid employed by the Early Treatment of Diabetic Retinopathy Study (ETDRS) to measure area and proximity of macular edema to the anatomic center (fovea) of the macula. See <xref linkend="biblio_ETDRS_10"/>.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_beba2673-d139-4f7a-8650-d66d10d8f22d">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_7e93115a-daa5-480c-a6a2-6cd21db9117a">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_5cb87c26-db75-405b-96c2-4631a0830c81">
                                <emphasis role="bold">Yes</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 2124" rules="all" xml:id="table_TID_2124">
                    <caption>Macular Thickness Key Measurements</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1"/>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a58bafcd-4fd2-4063-8607-1ad0b05d10c2">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d565fd0c-d9bd-4c54-8fd4-1d8ac15c8648">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2fb48b97-67f1-4c79-8568-082f15dedc87">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d9e9b423-1e1e-4e68-81cb-6c820b9c314f">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_904c6a7e-c52c-4f25-a094-4e0b06af3301">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3cbd22db-8be2-4ce8-99b7-49f4e54c07a9">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5985e9da-1c82-4faf-989f-27a67be03777">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b1402af-ac81-422b-ba6e-ef47aef1d3fa">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3fce5731-4209-4352-8aa6-3117e63b10ae">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24e2fe7f-be7a-427a-897c-8890a64adf50">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8daa8868-1b2e-4c5d-8ab4-eb3665e1c650">EV <link linkend="DCM_131243" xrefstyle="select: nopage">(131243, DCM, "Macular Thickness Key Measurements")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d0806e85-29cf-43ed-adfc-82713c946368">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ccf5e79-6a31-4803-a691-84ae112c2722">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7386936-c6c2-415d-946c-e66a97d77d25">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b9ee9d7-96e4-43b7-8eec-cffd7101318d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7587b95f-8bae-4753-aba7-2e970bafc46d">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04ded485-f692-4484-ab2f-50d127014f38">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2cc2b4ef-8039-4054-9c49-43871a19cf1c">D<xref linkend="sect_TID_1204" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_731ed958-87f8-4fed-b143-3a1bd2ed2c11">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1284042c-9060-4d8e-a548-eceeb4561826">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd56bb7c-ee1d-40ba-82d3-0d1c4d2f1563">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a836deb2-ccda-4d13-93ff-c26ecec2ae11">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5473888-b14d-4265-a9d2-d686231b1211">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ddfbd96a-9ef4-40cb-ad56-6a3741497e4b">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31f02d6a-756b-4a2f-a10f-85f3d83a155a">D<xref linkend="sect_TID_1002" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0ea054cf-6503-4646-950f-0ecedb5d571e">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a16f130-ec6a-4d37-ae39-76b70cf69205">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5bfeb049-64d8-4cf9-971e-c440ea5c526e">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24ffc440-c6fe-4091-b273-964c552153d5">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30e9e2fa-20e3-4139-96b3-29322546e9eb">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e5a17f2-b214-47eb-8648-5abf89462fd6">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e9add38-2e0f-4476-98c4-dd0e3b4883dc">D<xref linkend="sect_TID_4019" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c030e972-5609-4b40-bca4-0f514adb46c7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_016d8225-4ca5-4eee-a7db-488c69e5328f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_505e1362-240d-4a6f-bcee-7484763e9c2d">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5135c66-b389-4c13-821f-e08e35cdf03e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_32c1e454-138f-4023-9150-284242dc50f1">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb9b2a36-60b5-47c1-921e-61f2d49064fd">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e0d3b18d-5144-4dfe-9a90-1d124a7e5355">D<xref linkend="sect_TID_2120" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1e05e07b-45f3-40c0-b7a9-27f490163226">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_de0e4373-353e-4037-976e-019257712c65">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f520511f-aeee-4d07-b0bd-80839592832f">$Measurement = D<xref linkend="sect_CID_4285" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_857bc91a-bf2d-400f-b34d-ea1a401784bb">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_41a4c66f-f6e2-4cc3-ad17-1975b333bb8e">Row 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa55364e-3025-4810-b55a-6e0e12591db9">For example, <xref linkend="sect_TID_2120" xrefstyle="select: labelnumber"/> may be invoked once for each eye, or multiple times for a trend series for a single eye.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 2125" status="3" xml:id="sect_TID_2125">
                <title>Ganglion Cell Key Measurements</title>

                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4734cb5b-e430-4ef3-8b0a-3e23bc70d4dd">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_09905e74-c745-4475-82f2-0e8383f5aa5f">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_af6242b4-e7b3-4d5b-9c7d-1a16cb09fa67">
                                <emphasis role="bold">Yes</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 2125" rules="all" xml:id="table_TID_2125">
                    <caption>Ganglion Cell Key Measurements</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1"/>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f0363f5b-ac0b-4800-be22-9bee731fb6be">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9c8c7479-763b-45d4-8f7b-2bd320624f30">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_de12a282-c672-4f38-8ba6-5c92d219abb8">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7a881814-5177-4697-8f34-b0b66d3166cb">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f3c0104-9620-4b51-883f-5adf29e2e9ea">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8b2737f4-9e4a-4150-9f0f-53a8818e029a">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4b3329e8-aa0c-4546-ba64-a7926dfe45ea">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a58322c0-759e-4afe-a860-8b117863d5b0">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c9257c82-d912-4bb7-b833-a50275a5b4e8">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c72da5c-7117-4f70-9147-9d4af281b629">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c375f52-37ca-4b1f-8477-f16ee4a4612d">EV <link linkend="DCM_131244" xrefstyle="select: nopage">(131244, DCM, "Ganglion Cell Key Measurements")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_74c3a656-2c76-4de1-97e9-83784b6b1103">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3116c8e1-0d79-49f0-baa2-5825b41a16c0">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a6b1e84-bf15-47b8-a8b1-f89ee59ac58e">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e152444-5f54-4564-98e8-92fa646bd4ef">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eca1fbd8-4a64-4a7f-a5e9-d9481b30635b">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_40e996a7-6242-4a8c-91fe-9ca51da5852a">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75f118ed-4741-4907-a729-ceec8a83a2bf">D<xref linkend="sect_TID_1204" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cb1c43cc-ee76-414f-8a9e-0ae828b8ad0f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_71a084bc-7ea4-4be2-b42c-55519222a783">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0174641b-91a7-42e3-92aa-24d7e99c39ee">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6099c802-2982-4be2-adfd-ca40efe91235">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7e975c2-b9ca-4343-9da6-e6eba7db337d">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb528f77-b93d-4b77-a454-35bc49139cfa">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ce794c3-94bd-4e9e-90d9-8a97b0ae66d2">D<xref linkend="sect_TID_1002" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4cf6fb73-275e-45d6-b95b-03d2134360a9">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f743ef6e-30f4-4716-8ffb-e0807aa2e5f1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9147e5f-e507-4fe2-ab70-fdcd03cc2f53">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dda3e405-4e4e-4ec5-85c6-8d077ffce8d8">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f75ce504-d911-48b4-b01c-972602427198">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1abdd773-05cc-4216-81ba-abd56331454c">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd5127bf-e0dd-4bf3-a0b2-8dc807cc17af">D<xref linkend="sect_TID_4019" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ccfbff5b-3240-454b-8a17-71677c3327d0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_29bc8366-efa6-4b13-831f-2f9f9bf60df0">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a022e21b-b4e5-40a8-9129-a7671a0a2b8d">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_141c08ae-7311-4d9d-9184-06d501b1d045">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48fa4cf3-306e-4b6a-bb7a-2b0f2ece45ee">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7101725f-d3fa-4b8a-abf8-468fa5fb8504">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d523ee9-25cd-4ee9-8544-3b66afd7572e">D<xref linkend="sect_TID_2120" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_76fcf78c-66b1-48b5-b4ca-c8ef9e84fb93">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1c453e73-e9a4-4568-8ba2-ba03f248349c">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17baaf8c-9e12-47a6-9ff5-d0de122a9d9a">$TargetSiteMod= D<xref linkend="sect_CID_4286" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                                <para xml:id="para_188358ff-6528-4db8-9604-05b307e9f87e">$Method = D<xref linkend="sect_CID_4289" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                                <para xml:id="para_edbb61ee-bc1c-4112-aec7-83e1811ed80f">$Measurement = D<xref linkend="sect_CID_4287" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                                <para xml:id="para_c8450b92-b03f-4fdc-b597-5846fe965019">$OptMeasure = D<xref linkend="sect_CID_4288" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                                <para xml:id="para_19166448-1a6a-4046-b6a5-16c70d084baa">$TableName = DT <link linkend="DCM_131298" xrefstyle="select: nopage">(131298, DCM, "Average ganglion cell thickness in posterior pole grid")</link>
</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_f0da101a-e8e7-421d-845b-d0818948dd3c">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca51223e-5fc6-42f2-9926-390fa97f202a">Row 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6930ae7c-f2e5-475f-9ddd-2e6eadce571b">For example, <xref linkend="sect_TID_2120" xrefstyle="select: labelnumber"/> may be invoked once for each eye, or multiple times for a trend series for a single eye.</para>
                                <para xml:id="para_763b7dcc-f7f2-49db-b439-ee48338e2bef">Methods to measure the Ganglion Cell thickness vary widely. This template requires the SOP Instance creator application to specify which other cell layers, if any, are measured with the Ganglion Cell Layer proper (using a concept from <xref linkend="sect_CID_4286" xrefstyle="select: labelnumber quotedtitle nopage"/>).</para>
                                <para xml:id="para_06e8ffb7-1c4d-436e-92ce-6f169a4ac3b9">Applications also use various methods to identify different sectors of the retina when measuring the Ganglion Cell thickness. The sector definition used is specified by a concept from <xref linkend="sect_CID_4289" xrefstyle="select: labelnumber quotedtitle nopage"/>. Measurements matching the sector names defined by the method may be selected from <xref linkend="sect_CID_4288" xrefstyle="select: labelnumber quotedtitle nopage"/>. If the sector method uses a rectangular or elliptical ROI, the sector measurements should include both the ROI width and height.</para>
                                <para xml:id="para_debd4dc7-7522-476f-ac40-8c97720361ef">If optional measurements using <link linkend="DCM_131298" xrefstyle="select: nopage">(131298, DCM, "Average ganglion cell thickness in posterior pole grid")</link> are present, the SOP Class of the instance must support the TABLE Content Item Value Type (e.g., the Extensible SR Storage SOP Class).</para>
                                <para xml:id="para_b93efe2f-bdaf-47f2-8740-6bd35e3a192c">Receiving applications are cautioned about comparing or aggregating measurements from measurement groups with different measurement extents or sector methods.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 2126" status="3" xml:id="sect_TID_2126">
                <title>Endothelial Cell Count Key Measurements</title>

                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_96cefa35-5780-4f5e-85d7-1976e291e13d">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_e900bd12-256d-4465-9340-e1a5bae3d1bd">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_125e0ccc-a4b5-49f5-834c-fccff05ba1d6">
                                <emphasis role="bold">Yes</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 2126" rules="all" xml:id="table_TID_2126">
                    <caption>Endothelial Cell Count Key Measurements</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1"/>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e3eaef10-1c6c-4fe9-aa3a-192ab0b0f953">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_95cc6aaa-e599-41c8-89bd-b0d5e7aeb79c">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0a2b411b-f874-499b-997a-5b87780dfe09">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6b51b591-55d1-4317-a419-bc744757cd74">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ae0cdf56-0937-427d-aa37-b580178e0f4d">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b70a5074-5a55-4cfd-b794-ffbbf6712645">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5fd54c49-9df2-47f7-acd7-3f5134c19648">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b294a8a2-06e2-42c3-a2de-72e737f0621e">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_feb8522e-a6aa-4d6a-b59a-4150b2c19288">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5270e97f-241b-4a7e-9c76-d58ef345a000">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_217151aa-a498-43e3-9b6c-4bd3b37a5c52">EV <link linkend="DCM_131245" xrefstyle="select: nopage">(131245, DCM, "Endothelial Cell Count Key Measurements")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1348a9bb-44cf-4a29-aba9-7c5ecd461259">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_47394526-d695-4dcf-9049-d4e5543df6cc">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_47e216ce-4a60-41e7-955e-353195cf90ee">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3410359f-80dc-409f-ba13-f80c17add8a3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_18a97ef6-1db0-4fa0-8b3c-cb77445f6b42">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5e13185-900c-4196-a259-1b289e979fba">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4cc2b88d-704c-4c9d-95b3-55e7f3690d86">D<xref linkend="sect_TID_1204" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_538e41bb-f6fc-4031-836b-37d4767cc3e4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3fec33f7-3238-46fc-8c47-df9fcfedd088">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b16bfb29-81fc-46e2-95d7-88df2e95f247">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7381b43a-de9f-4d85-bc29-8dba63ec44ee">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be7af7d6-0564-4e33-81cc-7d1a17d42fd2">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8e6cdf6-9254-4009-9635-ea9186ab1df3">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_feaaf4a2-5db1-4f2a-be6a-50bf3bf50575">D<xref linkend="sect_TID_1002" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b7ba029-c3e4-4426-9ce7-0251389536d6">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_974230dd-adc8-4a9d-82a5-f94c0177544e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9237f391-ea27-4aed-b0de-62b7e6832f0b">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8a615c1-1c54-4a07-8b84-099d471aa15a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_640e1fe1-1dd4-480a-82dd-b04a9a386584">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_615c99ab-0aca-4dc5-bce8-4cb0a1e08f14">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c452123c-3f12-4540-b621-e027e8d3d212">D<xref linkend="sect_TID_4019" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_374381ff-5f7b-419c-9a09-77bfaa44ccd4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_863ff709-d36f-4a17-ac59-029b79d5ef4e">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c2d4a3b-3fde-429e-a005-1a405ea9bd2f">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93addadb-7fe8-4476-9dd1-a3d5717cde22">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6600e29b-e0cc-40aa-b4ef-11b7128be063">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b539cebe-c70c-474b-a38e-34126a83b0a0">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a547664-723f-4eff-9ae5-387fc31e0da1">D<xref linkend="sect_TID_2120" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_464f3713-a453-4c01-890f-b67a6cf9679a">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c82cca30-8cd1-4dd8-9f22-2ef7865a4e09">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d9c217a-523b-4139-84a3-0a00d7fdc69b">$Measurement = D<xref linkend="sect_CID_4290" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_6711eaf8-8a6d-4ddd-9a9a-7da4167a6188">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0925e0ed-53aa-4237-827f-1a5ecc015b73">Row 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1ef1ba9-6ab0-436d-b5ea-94247d23eb09">For example, <xref linkend="sect_TID_2120" xrefstyle="select: labelnumber"/> may be invoked once for each eye, or multiple times for a trend series for a single eye.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 2127" status="3" xml:id="sect_TID_2127">
                <title>Ophthalmic Image ROI Measurements</title>

                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ce023948-026c-445c-a241-c64b5634e9d7">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_018767ed-90f6-44d2-a60c-5d7b0907824b">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f1bf2710-b191-4614-83d2-277aa015f029">
                                <emphasis role="bold">Yes</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 2127" rules="all" xml:id="table_TID_2127">
                    <caption>Ophthalmic Image ROI Measurements</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1"/>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f09db9e-d807-4893-966f-4c2c9fbe41f7">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4afebb9a-07fb-4dbe-8245-47c16da6fc7f">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73ffe720-264b-4488-8a23-32797c7c4993">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6070c8b2-50e2-4ff1-804f-50c22bbcfd18">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1e97d86e-bea0-42cc-adec-5ed3ba285be9">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a47388a9-1795-4a39-ad06-2196dc27ac85">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8bd18d23-5a17-47c4-9a64-af8082586954">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8a0b1306-c63e-47dc-b686-4b366c3efe13">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f57dbb17-df87-4ea1-be42-a66b968a3405">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_591c7789-cfd5-4c6d-83b3-baf63aba5494">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5390818f-d37f-48f5-97d9-098e8ecf967b">EV <link linkend="DCM_131246" xrefstyle="select: nopage">(131246, DCM, "Ophthalmic Image ROI Measurements")</link>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9e43eda7-bb5e-4993-9d98-2323be519b7a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cdc4ab80-7cf5-40bf-99db-97bcde482d85">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6549b9a-4fa4-4078-bb9b-605b1aedca0b">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08897d0f-f73e-4be0-b278-7e7ab5718e56">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a901e08-c012-4413-ab6a-a26901e51421">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff2c5090-b5e3-4565-b8e6-ab8ca4a79773">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5eb317a-e369-4b57-b65b-8e01a1e74bf7">D<xref linkend="sect_TID_1204" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1c81af68-92cd-417d-93dc-4027580f1eb8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9cb0b554-af22-4b56-bf4d-05434e0e12f7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1db24d65-181e-46db-957d-e70108437685">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e46a586-bc84-45be-85c1-5a88d31404f3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_702e090d-7f8a-4138-8cad-dc9ab54b153f">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0259532f-15b5-44d3-8452-44bfae5c888b">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ef1727e-6d03-42a1-90a6-540e925d6e61">D<xref linkend="sect_TID_1002" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6fb67415-a9a2-4b0e-8170-5ca0b00ca6fd">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f9051c91-18d5-4a02-8938-74c54a00ef6b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_173f0ad7-97b4-4f55-952b-3b14327a8a95">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5089b443-ef18-4e59-934a-788cef312547">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae34f1fa-0967-43f2-8107-5e7323d05729">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61aecc43-a8d4-4a2e-9dbd-9a5ceb381b17">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e574730-ac4e-4159-973d-1abe2ee0dca4">D<xref linkend="sect_TID_4019" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_941986e2-d0c7-43e6-bf24-75d1461566c6">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dbad5fc0-fe9d-4668-ba12-58da182459e4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da6710b0-0988-47cb-be38-e8febbbf7e3b">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_747e6c9e-0dae-4c3c-b085-ea0bb74f0e9b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1f20a02c-0395-444e-88b8-7f1ea59093a7">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cbf3ebbb-300d-4d6d-aa95-89c4c5e59d72">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_47ef61cf-544d-4de0-bd1b-aab33c4ff822">D<xref linkend="sect_TID_2120" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c2abdcff-5886-4300-afd6-28678f7ebc4e">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c2492955-0846-4975-a5ac-bd5c054fba54">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d18f1cf-55b8-49b6-846f-2329369b4aaa">$OptMeasure = D<xref linkend="sect_CID_4291" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_0235b5e2-8dfe-465a-9ceb-e5d9be17e827">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_315e5a0e-82ec-4f06-b937-20109d725363">Row 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ac9b3d8-85f1-462e-b545-915c1fb52fdc">For example, <xref linkend="sect_TID_2120" xrefstyle="select: labelnumber"/> may be invoked once for each eye, or multiple times for a trend series for a single eye, or multiple times for different classes of measurements.</para>
                                <para xml:id="para_712bd308-a22f-4121-a0c7-6235de5d9e0d">No mandatory key measurements are specified. Creating applications may include any measurements or findings.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
        </section>
        <section label="Procedure Log IOD Templates" status="2" xml:id="sect_ProcedureLogIODTemplates">
            <title/>
            <section label="TID 3001" status="3" xml:id="sect_TID_3001">
                <title>Procedure Log</title>
                <para xml:id="para_80d395a9-0fcd-44e8-9393-fc4f5c57c2e2">The Procedure Log Template is intended for the representation of reports or logs of time-stamped events occurring during an image-guided interventional or other procedure.</para>
                <para xml:id="para_35c8701a-a145-41a9-8d14-7c641c51400a">This Template does not require a particular ordering of the subsidiary Content Items.</para>
                <note>
                    <orderedlist>
                        <listitem>
                            <para xml:id="para_e53f6f71-1885-42f1-af54-2d2ad65d53fa">The Procedure Log IOD (<olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>) requires ordering by Observation DateTime; thus log entries of different types (i.e., specified by different Rows in the Template) may appear in any order.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_38d67d8a-b515-48b7-9ba3-e499df63b30b">While this Template is extensible, the Procedure Log IOD forbids Container Content Items subsidiary to the top level Container.</para>
                        </listitem>
                    </orderedlist>
                </note>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_c603eb23-cf0d-48bd-92e0-62fd36a5aee9">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_7467b69e-da6a-4ef9-82a7-43221ffda6a4">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_a82a244d-f8f5-4ff9-a8df-910d4cdfba8c">
                                <emphasis role="bold">Yes</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3001" rules="all" xml:id="table_TID_3001">
                    <caption>Procedure Log</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1283e8bc-e6f9-48bc-be29-abbe384f7880"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_66170a9b-e582-4dcd-8c78-efc1f182de5b">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_94448dc3-63e6-4ee3-9647-e2d59a7779d9">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_df2b8137-5a0c-45bf-88cc-753b5f313f53">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8eff2f63-8b8a-4161-bf68-a2e29bfed452">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fa8783c4-2c78-407a-98f5-24c2c01d8751">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_afdcdbc1-fdea-4574-81d4-97e730a1ce3b">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3e6f13bb-ff8d-490d-bb53-d63aadf20df1">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a9cd5f76-5105-4380-9a4b-b5e1c3bcd441">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc44a892-5249-4e8a-97fd-0d7f0543223d">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7a49c82c-67d8-4a11-8ebc-864b231895be"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c28288f-ce59-41a6-b6b0-ad6703ac662e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48833d24-a9db-4442-9c2c-fbdbef874fd6">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e49acab-290e-41f2-9001-47307cd15b4e">D<xref linkend="sect_CID_3400" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8b93cae9-1099-4a0c-9997-66b7515364f0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c3927808-4af4-4e64-8399-aeb190e1d711">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee9f69be-d974-4d80-97eb-2b145264281d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80898ade-c8ff-42ae-b17f-1d537dc3712e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dad697d4-470a-4b0e-8ea4-0216b20ce6d8">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d71da402-40d7-4e2a-a3f1-33a45537cc16">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f79053b0-54b1-47ad-ba70-fee2cee2ec65"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98043dcb-308a-4646-83f8-c0a0eafa05a9">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_619ca65c-19c9-4216-ac33-e9e9eb8d683f">D<xref linkend="sect_TID_1002" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_145b601c-05bf-47e5-ba39-b477a3757932">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69d983ee-72bd-4827-a063-ea5ac2d61bc8">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0beca56-d351-47c5-a3b3-11e28cffaeed"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c64f75db-8ade-411a-9dcf-82027a86f3ab"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ac33cfa-c4fe-4894-b88a-cdf300c42e02">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81ed9e0a-cfa4-43c6-9e7f-cf75bc825e78">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9595e4e-41af-4ea6-952f-bc598ef419a0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96929182-4eb3-4332-8c8c-e17bfb61ab08">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02b82923-ba79-4b8b-b57b-42d0586817af">D<xref linkend="sect_TID_3601" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c604ad97-ffb7-4c6a-9df9-a29ec2611c8a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1518c9fe-1245-455d-bd41-ed7c215e9243">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0fbb5d3a-85ca-4d85-b330-b0f1d1a64d86"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4aa88343-0dca-4b9b-b363-c491c6f5b05c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93e3a958-275c-45d9-a44e-4e80eabedb0d">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98886346-d5f1-49cc-8eee-e2fa684a3a37">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c2a927f-e1e5-4d3b-ae51-4335cdd9e71c">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9cb03c7b-7ad7-43b9-be62-a91c38577219">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98055377-2b3d-4bad-8286-f5dea0756d07">EV <link linkend="DCM_121121" xrefstyle="select: nopage">(121121, DCM, "Room identification")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_34e2f918-6fd8-4df6-b458-eef8c6618dae">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb2abc64-0ec4-4abd-826b-2e066f429265">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d468ab1-308c-4a27-ba52-3144ca6dceae"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9dbfbfe1-4578-4a69-b1b2-f4d010e1e568"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dcad01a9-f35a-4221-9ebc-05dfcd564b52">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb8e0b31-ee6e-435d-a57a-c6f2f06dd92b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0cfb4346-4a6d-4caa-816a-cc838e675063">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f84d672-0791-4f3a-a97e-14a1282d0e55">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_945aafd7-c65a-4b40-94d8-5a41c9b49088">EV <link linkend="DCM_121122" xrefstyle="select: nopage">(121122, DCM, "Equipment identification")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ccfc829a-f888-45f8-ae8e-d81df0f02a20">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_027ffe3b-b1cc-49b0-b046-61ca5cd4aed2">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b2d7d0a-9f1b-4728-8d79-81b2626443f4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d2e25f2-12e6-485a-a934-9ed4c681bee5"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ce40c60-3203-481d-b217-f9cbd2f790cb">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d66ef2dd-3388-477c-b25d-c03db3edf3dc">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4954ee9-b329-447b-ae86-4c00b02f0d8a">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_710ed6f5-6e9d-4b28-9b14-cec314e49792">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5611df17-1b19-44e0-8215-dfe8ef35f5a8">D<xref linkend="sect_CID_3401" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_de20931a-df04-48fd-8cbc-063ab6a10191">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_af797600-2b70-4f13-91c3-dd797b59ab90">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ff11829-a275-43b3-8f31-cf0386a6d547"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_94018ecb-32c9-4bff-b9ba-5981cf30d973"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_663f0507-6846-4cb1-87c1-000e71534ffa">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9bb623f-1e98-4637-9dd1-033041bee9b0">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eec43ab7-e07a-4cb8-ab75-014c6c5ac1aa"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25779b39-6085-442b-b687-c26b4ec345bb">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2458223-b5e9-4a2e-b09c-4925cf5b9e29">D<xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cd46628f-c5fc-4361-97c8-2208a436491a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d458cb20-8fa3-447b-98b7-03dc5be57369">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f26aac82-d2a8-442a-bedb-919806343899"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c02f50f8-64d8-4ee0-b4b8-6d78f25c9f05"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31374700-c09a-42ed-9313-6e41be9c2586">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2f68476-51d5-4559-a191-306fb07b69bf">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4342af07-f01e-4072-ab8a-21a3ff789392">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d320e765-1c11-4391-bdad-295895dd4ed3">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f51e0e91-3334-4ace-961c-adc914566fed">EV <link linkend="DCM_121123" xrefstyle="select: nopage">(121123, DCM, "Patient Status or Event")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ef97d40-0415-44a3-8ad2-b393016a3086">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f40ab7f1-1f7b-41e8-a221-c1aa1509f953">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_20630592-2ae7-4149-82a9-260a50b68da4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00a3b4bb-4113-41e2-9dd0-c7016f4f72d0">D<xref linkend="sect_CID_3402" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d839960-d9a9-41d7-91d7-62877553a6c5">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4800b79d-f5b6-4337-b1a8-f668aff8a133">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0c992470-1dfd-4745-9ea8-a82725be8f49"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b71a3134-b094-47a3-aa0e-2d8d75e2ee43">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bdceca56-bedf-40d4-8719-89a49939142d">D<xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1c541a0e-c9a6-4a66-877a-a3f4c2f0c7e9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_da71dae6-7071-493b-843a-d79501228127">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9bff189b-74e9-4176-bdd0-7f9f6d9766bd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9910695-682e-4c30-9c0e-c7407fafbd7c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_358a100a-c16b-492e-8039-9d160504c09b">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2016866a-875e-4948-9c90-aee213560b37">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe8ade13-8b3e-4975-96c0-14e6e052bdfc">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80ff5c35-d4f2-4ef1-8d44-189d02cacc5b">PNAME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d4d21832-5bbb-47e8-8b6c-77cb04065831">D<xref linkend="sect_CID_3404" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf6b672d-4480-4601-98a2-43137238e616">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eb702e0a-ca1c-4093-b13f-2ab4c5fd85fe">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09d098ca-f0ec-4e51-a16a-d76af94e1a8a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc807cbc-8f2a-404a-8086-8399c15d2b80"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f3db502-603d-4427-b9be-6777b7604190">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4f33648-6064-4d1d-aa17-b7b975e06f66">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81290322-2d21-4adb-9f52-b0f43994b9df"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e7d404a-3779-4169-a82c-f1a860309170">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_091ba9bc-b7da-47ed-ade5-dff8dba0d5b6">D<xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0b16a2ac-9a95-4a92-8f74-d911be01f076">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5c9c0203-c968-4e90-91ed-2099d28a0bf9">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d3ff032-414e-4c46-a59a-4e7586a73d30"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5969858-1b53-4611-a065-eb5d4c328d47"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c6fdc14-3e10-484d-bdeb-4ec39095c665">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aee7ccd6-f355-476b-8717-9f96f56b2545">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38ca55cf-7f7e-4e5f-b433-e4ba70433c3c">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2168834f-7a3b-4a8b-a230-5929dc438581">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_15f171c8-f533-4e35-9be3-99b8ef706643">D<xref linkend="sect_CID_3427" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2c7e54fd-2dbb-4d90-a2c6-991db27725d3">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_acaf8ab0-b7fb-4b59-867c-e30d94d9dfa2">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85e96b0a-d726-4a62-8782-a62d7e5c1312"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d7f529b-cbf0-42a8-84a5-292f9f1373c1">Equipment identifier</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92e9615e-a3a9-458c-95f6-f72514cde981">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f20eea33-2e63-43b2-abc1-25effb7a542c">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed5b9a38-e579-4afb-89e9-4615c5a711a5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_455a9461-ca34-43e6-bb38-6f62590783b7">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_055a9486-ae50-47a0-9a58-e8d460713529">D<xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8ca21de8-4362-4e3b-984b-5a68401186f6">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b78c21d-df6c-43e8-9bc1-6ca572e33980">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f083d6e5-e8db-4c7a-b91d-ac2c82529121"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84ae50d3-c83c-4c7e-a649-6c582aa4ada3"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb76fb2a-a491-4bec-b2ef-c77cc88935b7">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35f16355-f999-4043-8e10-1e028e094740">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10a48283-417a-4345-8b16-62c9447279c8">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f825c95-8068-49a3-8433-8800113ed8f2">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0b4db77-7906-40dc-8c85-95028ae07297">D<xref linkend="sect_TID_3100" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_72525699-c451-488c-82fd-e77fef5b8be8">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c5ad969b-3518-49d0-a438-af7f2a412ea7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5735302a-b611-4a89-a727-d3ebee9a68e3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91c7d266-cb82-4722-b48b-f9056bdc76da"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_532264fd-2899-4d82-b76d-32b13afadafd">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08da1a6d-8c58-4db7-8a39-8e4165dde0c7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a0dadcd-2322-4d25-aac4-7da371aaab62">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8685979-c52e-475e-b7e4-8fc50bd5dc11">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ab1b7c1-56e0-42c4-88df-c7025e7c0ef9">D<xref linkend="sect_TID_3101" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_572cde5b-f508-4e1c-b02d-6553e5c79945">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6795b33b-1f0d-4de0-921f-c4fa5bd1918a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c707bbf3-a450-4b3b-ba6c-829747a76489"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9a8923c-c268-45ac-a6ef-359d6da60444"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f67e302-1017-4d57-a5fd-29af9320afa1">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54658e9b-73ac-47f6-8beb-44d4c436e311">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_471aae41-c9e7-4f8f-83a4-ea47032adaf4">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d2164ffa-04b3-4863-b09d-1270c357b97c">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_267294b6-b6a2-4490-ab05-9fe1709e8450">D<xref linkend="sect_TID_3102" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e1d726d9-acf1-4b99-9515-b23dcd1da458">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_10b763c9-2764-4204-b897-5b234ee4fdd1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f59ea00-9d27-49e8-9e43-ac020e09d37b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a1cf2f53-5295-40b6-ab68-ea0a7de7d9ae"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75258207-f83f-4cae-bcfd-81c50e8c5281">17</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_432bcbba-8c23-426d-87ee-1daa383e8d25">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79edf123-c871-4f0a-b0a7-9b27578de6e3">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb9c86b9-0154-4f7f-a4b2-b8f8e9a6ff6d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_18b8470d-f9a5-417f-9b0f-4ebd3765741f">D<xref linkend="sect_TID_3103" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2eed90ce-e6f1-4f4e-aa53-f916e32e9fcb">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a45f2e79-7062-4f05-bcd2-751486018164">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_76152427-7748-4713-896f-121fa9eeca76"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e68006dc-4eb7-4075-a520-b74ff615f7a5"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c94f7bd6-eb00-44e6-876b-4096c70a7848">18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0682908-88ae-4bee-9529-ee01f26c7627">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e558b6b1-9089-492d-9dfc-07e2a870995b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_308a3c2e-2a70-474a-bbbb-e96475824180">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5b19d40-c3cf-4e83-aeec-fe68563a6411">D<xref linkend="sect_TID_3104" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_79dfe5ba-29ea-4f77-93f0-bbe930681f8b">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1c0e0e0a-fbf6-45ea-9934-6d9ce422399c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f7761a44-18fe-4f5e-9093-0102c03ad00d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da761206-7fc4-4125-b755-28ce49dee3fa"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c5e0e25-4be8-416c-a632-d0eb775bbfbb">19</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7878bbe1-0e9b-481c-8b3d-e3c933d20077">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99b52ec3-7ded-4d61-946b-0f10a3416cb2">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_122ebbc1-6d9b-4f26-9c29-3c0916998081">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_66cef596-ff6d-46e8-88cc-966e099136e2">D<xref linkend="sect_TID_3105" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f27b758c-8ca5-4ea8-b6ef-025847aa49c6">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_34e2334b-5382-4f2c-9dcc-8ffee3f041c8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3732761b-b218-4a9c-9d66-df4b5988a139"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c367becb-ef51-42fa-83a4-b4a6529cbecd"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e82e5040-f4d9-4a34-8a30-0386ceec8a51">20</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_135d656a-2c1e-4654-a329-5915bf167e9d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c458267-ff9a-41bf-a49d-48c3b81236cf">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00b337a7-5716-4c13-860b-89cc97035630">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5d08f8c-a6cc-4907-ae72-411064e3da4b">D<xref linkend="sect_TID_3106" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2c26ae60-83e9-4ca6-a1ee-06ab977d79e6">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8b45fb21-11bf-4f1c-96fd-8141988ace85">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87689b02-d13b-4619-85e2-1e93fb3f7a1e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c3b2360-ac61-4dd0-b1c5-e3b229f667dc"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a820fbf-8a30-4406-b2a3-c4346ee9ecab">21</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_572cf60c-39d1-4a58-aef1-72ae14d8b784">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_beee807c-c7fb-4ca9-9f8b-701ec55a6807">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13d735ca-e37d-493d-bd4b-2d200a88dbba">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a4ff020-c3cb-4e83-a703-945a97e0963f">D<xref linkend="sect_TID_3107" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_305c9623-010c-4d6b-8bc3-03e6566bd514">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b13bee90-c9b3-4f05-a9f3-d889eef43411">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_679f7d76-667d-4279-ba2e-4e23843c4ac8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b76f2d7-5942-436c-8010-20c96aab606b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_129e0eea-e967-4b05-b230-d325fa04331f">22</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30213e4a-1d83-48e7-b506-176dd5bb3858">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aeb4a1ca-6631-4827-bc5b-a6f4dd2ac8bf">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_78caea12-6eb7-44e2-8e40-0113b4e202a7">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df6f9f15-1d96-4be0-be69-a00829e3bd6b">D<xref linkend="sect_TID_3108" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7c67c53-d391-421a-a0e2-456c921bf0a2">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1bf05aac-d6de-4035-8c4e-a350268f2325">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc2d077c-2f65-4669-97be-5d54965b664a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_68903e9b-ce6d-4c7e-9527-badd09ff3365"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae22a092-c825-4205-8f40-8d314365c67c">23</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bfec3ba7-bb68-4c43-b1d2-899b200c85cc">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce56e7a4-b604-4dd6-8f45-9d5f2441babe">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d328621e-2750-4c06-a455-a6a3ea5e85d6">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c11b7f3a-a7b5-4e31-9165-9fa2381d6bcc">EV <link xl:href="http://snomed.info/id/116224001" xl:show="new">(116224001, SCT, "Complication of Procedure")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e9078a12-b043-4ddc-a4bd-454ab74b8398">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ae5ce774-a759-40c3-8e71-021d06eab580">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e21a0a69-995b-4b02-976b-5992a3492abd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de850edc-f443-4b34-9978-75e6144339d2">D<xref linkend="sect_CID_3413" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e1bb12c-23fa-49d0-b153-a2544faefe91">24</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22a34098-6064-46e8-b1e7-cfffa2d4f96c">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee987de1-6eb1-445f-a773-ef2ac972a316"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1dcb6c2-09ee-41a6-af4f-06fe9c9f3cc3">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f07c8792-a26b-4da2-be15-5560ac4b155c">D<xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_09a320e5-95c9-4874-b08d-9705449e5db3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8d25ceac-85a5-471b-999e-c4de0f6b8183">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9bdf5ee1-bec1-4022-b87a-85e6d177ee34"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0b0e777-b31f-42b9-b107-443a7306e524"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bae8ca2f-d7b7-4155-a3ca-6df7b627d777">25</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1473915a-3610-4621-8309-bcb729209484">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8223444-52a7-43c0-b2da-887ead0c9fd7">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d35d5f10-8631-4d0e-8db9-71581b238a88">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_331213fa-0750-4cb9-b759-1377e13e22a7">D<xref linkend="sect_TID_3109" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_97b309ef-e953-4b40-a8ff-65ccaa171e23">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8a65d6c9-9c01-4c61-b532-0f9dff3bc0ac">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6149ee9d-b97e-469f-8f6c-c4a406f732d4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85671fa9-75ab-406f-b51e-4107ef035000"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b0e0fe0-c717-4524-b09a-57ce51dccbd3">26</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1f1ee659-e7dc-4312-bb87-b14cd936e79a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bab13f68-24c5-4e71-9d48-aaec8f41c742">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c61d85de-c84e-416f-aa2b-f8753373aed4">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87490806-7155-419a-a830-76cf8b294fd2">D<xref linkend="sect_TID_3110" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_592c73cb-064f-4a08-a633-423bff655b9e">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b77d7912-5f1f-4d3d-87bf-86099bd4ee47">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_60e1feee-9444-42bd-8b64-e6ddd57f83a3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58c8fc8a-b759-4d12-a371-b9f76700027e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_68ab09dc-b981-4870-bf84-b219d0884d3a">27</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c4fe98a-54d5-464a-99b3-02de8c010208">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3d07bbb-2159-445f-9b91-2d35b9a0cf2b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_016721d4-0253-4b21-a4d2-343174d3bcad">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8923769b-9ebb-4343-8ced-20039aa70566">D<xref linkend="sect_TID_3111" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_057d5d33-57f5-441f-8330-f2859ab7d5d2">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c36b965-d92a-4cb7-8b59-9ce7f7ab487d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_71de3a28-4899-454d-8694-7ddaa8b9c11f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb3de2bf-9d84-4212-a33b-581b6b5cd5a7"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1531446d-7a12-4195-b7ea-0388520f04ef">28</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_90b54410-b95d-47d6-affb-1bd1eddcb6d8">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3790ebb0-1bf0-4af7-8c5f-3b98666ba944">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8c14247-dc7f-433e-9d8e-4c79fdc0b075">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a287bfa-097c-474f-9944-39ddb18ab601">D<xref linkend="sect_TID_3112" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3e8abfd1-649a-492d-bf42-7cd6dfd3c3ed">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_10b2491b-d8fe-4a79-88f5-b1f0f0131219">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a445d303-7c5b-4d4c-a440-65d3e2c69b5c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_34258e62-a236-488e-8d86-ae4943366838"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0bc06f9e-22e4-4235-bc1f-ca9a8a994aa4">29</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e1e67221-e739-420c-a122-3f9f9a1ba4d0">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1af78611-97ac-41d6-a203-3d3a25aea40a">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6c07892-2fb9-43c9-a0d9-8c8f9be8ab26">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13cd9d7e-0db6-418c-8e80-42308ee4031a">D<xref linkend="sect_TID_3113" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d8661261-5d8a-432c-97db-945abd759736">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a7b8a57-8f37-427c-9c5c-05387e1f2fe0">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36a548ce-a692-4db0-bcea-53289b0f7992"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a07f0c64-194c-4bd4-8201-dbe52d729cea"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff8d39b7-1d36-4168-9bbf-61ee4a21990e">30</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c023e005-109a-475c-b380-debe914db98b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_351cbed9-be46-40ef-ba2d-5bbdab6fc6d4">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_77986b1f-b658-4121-a4f7-937beeeef8e4">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f56df76c-41b0-43dc-9af7-6fbe38a18ea1">D<xref linkend="sect_TID_3114" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e9a2d3fb-1340-47c0-8eaf-2fdfd0a80fc1">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69b61ac0-73ce-4ba0-8da0-ba14731789d4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58bd07a9-8a84-4bc3-8309-be9106142468"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c86663a1-9ae3-4d89-9939-cecff13dfb48"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_703c21ee-0587-4774-99e0-9061e557b14a">31</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b21d92f-5e18-4687-9c57-904096e6d834">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_092c79ad-ba33-45b0-9f43-24860fe4ecfb">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7c2abec-429e-45f9-8d11-5abbf773fbb3">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_248780be-1dd4-4cf7-9f64-a98f3fc6594e">D<xref linkend="sect_TID_3115" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a3c1062-81dc-4abf-bc22-c91be7c61e06">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f7ad8f57-45fb-417d-97d6-9014ab97cbd2">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35b71d1d-ec8a-4581-a793-09dddb4422d1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c91cbbd0-06a7-41da-8f3b-f48fe4a929f7"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_4b66a395-62fd-42bb-8a7c-4648fdf6f715">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aca32f7a-ec9a-48a6-b5fa-1ad594456030">Row 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc089d17-1c2d-427b-a51d-281ab3a20477">Includes <xref linkend="sect_TID_1002" xrefstyle="select: labelnumber quotedtitle nopage"/>, which shall be used to record the identity of the person responsible for recording the log, as well as all other participants in the procedure, even though these personnel may not technically be "observers" of the Procedure Log. As participants in the procedure, they are potential sources for events and observations recorded in the Log. <xref linkend="sect_TID_1002" xrefstyle="select: labelnumber quotedtitle nopage"/> allows the specification of the person's role in the organization (e.g., physician, nurse), as well as the role in the procedure (e.g., circulating, performing, etc.).</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_586c647b-c77e-4bc7-9ba0-ad94d658948b">Row 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f5b2d32-5dab-4e3d-98bb-51df5a08e66e">Shall be used to record the identity of the major equipment used in the procedure.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83711bd7-e205-4bcf-a0a8-2fe1da90c934">Row 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f5b5cc7-8e25-4e78-b04c-2191dc94d43c">May be used to record any event not covered by a specific log entry Template.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3010" status="3" xml:id="sect_TID_3010">
                <title>Log Entry Qualifiers</title>
                <para xml:id="para_d7512ef9-b44f-48b7-bccb-d1fa64548d1f">The Log Entry Qualifiers Template provides a common means for adding additional description to a procedure log Content Item. It allows identification of a source for the procedure log entry (other than the recording observer for the log as a whole), a free text comment, a link to a particular Procedure Action item, a link to a particular lesion, or the date/time of recording (if different than the time of the event occurrence recorded in the Observation DateTime of the parent Content Item).</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_8af80991-e778-4ee7-8e9c-a10e7d36397e">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_3c88a474-9e44-4d1d-b447-0bb74c631e88">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_83fa0cd1-91fe-4474-8119-cb7a2b05509d">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3010" rules="all" xml:id="table_TID_3010">
                    <caption>Log Entry Qualifiers</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_776f865c-e331-4a09-8410-a7f28a3e9212"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aa21b0bd-bc38-4c49-8c6f-de90be83fe40">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_99cbb691-9c2a-4c9a-ad12-dd57ece15c8f">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e8460612-4bfb-4c62-9a5e-eb393a6a815d">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1533ef25-63b7-47a7-8748-faddccd63a1b">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4119db24-4372-41cd-a424-41756cc9fecd">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6245bc8f-cf58-4b85-bfbb-cfa15a68591b">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_499bf21d-e622-4bf7-9902-bca082c3db3a">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8b7f10fb-0bbe-40ad-af4f-572b783b10af">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67bcee60-8f48-4086-9869-f5c38fa5dd27">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b6868dd-a9d9-4f92-90db-f5d2ea5a6c7c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b708833b-be7c-4320-b7fd-020dc3c27913"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7af2eae1-08e4-4c87-96b4-ab3bbd38c69e">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e82e4f57-43a0-4751-92d7-9aa611e7c2c1">D<xref linkend="sect_TID_1000" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_75eb4bc4-4156-433a-abd1-c7d721048110">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_14c95475-9cb1-4c55-9599-0ac663ab44c8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_94f9a664-1779-4b65-8c76-f7a8542a0df4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_545c9cbc-7ccc-4ee5-a7d8-2eceea5b68f2"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6da53a79-10b4-42bc-b57c-4c2c06bd526b">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4cbe3686-6a02-4a4b-9ee2-5e4d2a44f4c2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0415bc9d-151a-49ba-8e06-414b666573d5">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce8e9824-7872-47dc-abc8-1608aa161844">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f447feff-71a8-4abb-b6ac-2c02727e7d46">EV <link linkend="DCM_121106" xrefstyle="select: nopage">(121106, DCM, "Comment")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_439b77b3-bf2b-4d9c-b090-a594299678d5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c550ab5c-7843-49bb-bbfa-be33271e8f7e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54a8b778-76e8-443a-9d8e-230ff4b7d8d6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb1be322-e1e5-479d-85ef-a49e1c3a215c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_735b6ea1-5a78-4069-96d8-3a2583cff223">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dea15adb-16db-47b5-9f76-6a00e6eb8878"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2967999-cf29-40ab-b08d-c18945d31416">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf270791-3912-4014-bbb0-39e2fb0081ce">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0473c27f-cc06-4b63-8ef6-c59f737e032b">EV <link linkend="DCM_121124" xrefstyle="select: nopage">(121124, DCM, "Procedure Action ID")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0f8f838b-d2bb-4171-9559-2af7d891bce5">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_38ee227f-d60c-41d3-81e2-71c30a343b5d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_90a7b184-8b9e-40d3-ac0e-4902681b9d59"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dccd7568-97a4-407b-b01c-1027b47a3b65"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c47d075-5896-490d-af78-2e26c23741ee">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30f6b32d-6e77-4718-92af-46dde85986ae"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e1420f8-f6c1-4614-9bbf-336eeb4785b6">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb0b2841-55a3-483f-a188-99e4855c72ad">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11734862-3e41-4c19-984c-ee94b07aa5ea">EV <link linkend="DCM_121151" xrefstyle="select: nopage">(121151, DCM, "Lesion Identifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7c73463a-2718-4afa-be55-754757a98700">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_767a6ede-2e3b-4295-a578-9d16d1344ceb">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e63ab214-2fe0-4ffe-83bc-5f033dd98916"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_536a42bf-5cc0-419b-9014-a9003b7b9ea4">Up to 3 numeric characters</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_598023e3-7309-4176-bdd1-6b0a6eb5bfb2">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ddcf458-abc5-4f6c-8f4a-37a628d0da60"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d11e2208-c012-4fa4-a789-905b977f6ba9">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cabd5bc3-e357-4eeb-8a6f-d97b08c082b8">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3daa75dc-2c62-46f9-a3c4-51c48c0eea24">EV <link linkend="DCM_121125" xrefstyle="select: nopage">(121125, DCM, "DateTime of Recording of Log Entry")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2e8183da-2603-4db1-a41a-0d94967a31bc">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ff3ff515-f4e5-4a54-91dd-75941f97955b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11e42e1f-2168-4ec0-a34a-290e480d045a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81551b9e-4654-43bf-9421-f7bb4d4f8aa4"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_642e69cd-27c6-4988-93c3-4fa3e9833917">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba0ca771-0aea-406c-8e00-ff39df837d98"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1060485e-e41c-4598-bbc4-426e15ad1ac8">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3211c353-9b85-478b-9a54-bd3bb3735e26">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c3492b55-70de-48b5-a85d-6fc5da0d17ff"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8dc30c2f-8694-4914-8ff6-5423cce8abab">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_57e1f98d-f008-49a9-b993-42df97226e80">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_afd5707a-ca08-4d28-a87c-85e05657bed3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79ca7b4b-1a08-44c3-a120-49d93efa9ec9"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59ee8427-9c99-4f57-b9cd-1aceb0063ef7">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69afa5fe-b710-433b-93d9-38e832595578"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0427dd34-5aa6-45c6-8a8f-1c389148d528">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_530789ac-807e-4fe5-98f2-11eb2c54cfaa">WAVEFORM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a58c250-3e80-43c2-bf8c-9f3a3a05c8d5"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_082c36a1-1d4d-4f73-a36b-e0b2a9a817b4">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3683c8b5-95ea-4c9e-ae90-e6238ed82106">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8979247e-00f7-478b-b88c-135821db6965"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fbd3da90-ae17-4845-bc2f-2a7a34b069de"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_95816dd9-9108-46b9-9785-3b885c44892d">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd17c4c7-2e09-41a8-8bb5-d1b1ccb5bfb0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46da769d-0d96-49d4-807f-b1552c28fb23">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a567dc01-545c-4d4c-a780-d0d76241b236">COMPOSITE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae484013-a50b-4772-98c1-6dd234d43dd1"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d0164e15-c234-40ab-9631-2567002dc76f">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d8fe861e-9fe1-40c9-83c6-324d5abd65bc">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce88253d-48e2-49df-8930-6f74e5a00fe4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c6607708-6b61-491c-8d33-f076402b6423"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c230e6ad-effb-4235-bcb1-0654f65a77e0">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ea475c2-1ea2-471d-adbf-b6b0fca2c0dc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0fa0652-8c50-492d-be30-f7f9842a580b">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ddb7485-d107-4934-90fa-fc1b3435867e">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d4c87b8-0dfa-406b-a9fb-324d7333bf45">EV <link linkend="DCM_121135" xrefstyle="select: nopage">(121135, DCM, "Observation DateTime Qualifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3d180df5-72aa-4c0c-8bba-a10ea5e66abf">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5bd65996-a937-441f-af3c-ccc2eab6934f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8c68090-7918-4fb5-8640-a5f8480d4865"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3db4bbc1-2691-424c-8ac1-182b65c195e9">D<xref linkend="sect_CID_3430" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_91cb81ef-d0c8-4ee1-bdb1-44eedad83366">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac35410c-0da4-4f35-a09c-8777ca7a8071">Row 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e01a8aab-07be-4f61-b171-4c1c55f86b85">Procedure Action ID allows linking recorded events to a particular action, step, or phase of a procedure. See description for <xref linkend="sect_TID_3100" xrefstyle="select: labelnumber quotedtitle nopage"/>.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b019d8f8-1143-4e17-b0b4-75a5ea810336">Row 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_95674027-4924-403a-bdf6-f592ebc00610">Lesion Identifier is specified as a numeric text string, and allows linking recorded events to the diagnosis or therapy of particular lesion. See description for <xref linkend="sect_TID_3105" xrefstyle="select: labelnumber quotedtitle nopage"/>.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3100" status="3" xml:id="sect_TID_3100">
                <title>Procedure Action</title>
                <para xml:id="para_afcf4606-35bd-4c22-a7b1-efc5fa70354e">The Procedure Action Template is intended for the recording of the beginning or end of procedure steps or action items in a procedure. The level of granularity of the recorded events is not specified, and may vary between institutions, or even be at multiple levels within a single procedure log. There is no requirement for the real-world procedure step or action item recorded with this Template to end before another one begins; there may be overlapping or simultaneous procedure steps or action items.</para>
                <para xml:id="para_b4fdebf6-78b1-4fb8-9622-0b6f005f6f0d">This log entry Template may be used to record the start or stop of timers.</para>
                <para xml:id="para_ec700b87-07df-446f-b429-628fde5fa3bf">Other recorded events in the procedure may be linked to a particular step or action item by Procedure Action ID (see <xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>).</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_c22868b5-2fc5-4e16-9715-167a3318b1a5">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_dcb4ead5-36cd-49eb-9506-93542549682e">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_e7975083-2e3e-42da-a616-ed48ca0f5709">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3100" rules="all" xml:id="table_TID_3100">
                    <caption>Procedure Action</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_02c9ed80-9b8f-4151-809d-82a97a253ef6"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_da1d5b71-c2c6-47db-b655-464bfeaf1ee4">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_970c2dd7-34b0-4634-9a08-8ae4fe8d4971">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1cd73bed-24b5-48ab-8a5c-655dd84749f5">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6eaef434-10a3-4d92-aba7-e4efbe9c24d6">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8dc7eef8-5493-4ef1-b6db-e4aea1a01554">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1685981c-9563-4286-bbbe-75c40fe9bae3">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5656e331-6456-407c-ad53-2eab98d04029">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a25def28-d5e8-4db8-a090-7d8bd7932389">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_14f625c4-87e3-40a8-a637-a3f102294556">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ab9b432-6e96-4a18-9f02-df142b264462"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_660b8db1-3b81-43e4-a789-57bc9118e7e1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c15a8cdc-1570-43a5-ba4b-2d28329990c3">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c40b84e-1a41-45a9-95bf-d86c1923d4e2">D<xref linkend="sect_CID_3421" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_35fb7f63-fa0c-4ad8-b0c0-11202423fc87">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b47b7c95-0a0f-4562-a24e-60bc1e7811bc">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c51d737-0846-4394-9ca3-0d0900356d87"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1366850e-d7b1-40b4-83b1-f8056c4a8dbe">B<xref linkend="sect_CID_3405" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_18041693-c81c-4baa-b0f7-dc94fe9f6f0c">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7caef66e-4efd-479c-9440-73bb27a7e674">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6cb63e75-535d-4203-b0b2-246f3c6ce994">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9657ff0-e6af-4f98-96fc-90059b32455b">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0fda17f-03ee-43c1-84e9-4eb8340db9d7">EV <link linkend="DCM_121124" xrefstyle="select: nopage">(121124, DCM, "Procedure Action ID")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a341edd3-11a7-4f7b-9717-ba2167d7dcd2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_658ebd05-d21a-4772-a7ae-cb495ce7f681">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bfb8c1e7-82cd-4eec-8d79-fdba116e401a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d070f7e-809b-4e7a-95e1-a7ee6427085f"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3f01098-069c-4e6e-85a4-bf210133a5b6">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d56b07b9-2ce8-4727-a34c-7ed83228d90f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ff4c0d1-8d8a-4723-a72f-533118b52415">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72f9b962-65cf-4862-8602-ec58b9b90b2a">PNAME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b32424e8-cab9-42af-ac00-55a3caa8a4f4">B<xref linkend="sect_CID_7453" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5f65956b-654d-4bf3-a711-b5b60b8d53d6">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_39cd0bc4-25fe-4145-8b14-14aaf4bbcf54">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0cd23c51-1b8e-4d54-aced-6fcadd8f56b5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ba3e4e3-0cba-4cf1-9fda-ae8ccbb3b21b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed2a0f9b-347b-41f2-b4c4-c057d37e8929">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_246bc174-588b-43ff-8ec1-37998f75cc9d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1db294e8-56e7-4b59-8e65-882dbfc49857">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2b73dfd-97c0-4db3-9254-102d78054a4a">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99879493-45ae-44fe-9f5c-3d85bc4e138a">EV <link linkend="DCM_121128" xrefstyle="select: nopage">(121128, DCM, "Procedure Action Duration")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9f6aeadd-772a-426f-94e1-2f4c9651c2ef">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_baa6f4f9-d882-4cd0-a514-1cb6325256f9">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd712af8-b75b-4b58-8e1c-e5c78f2cabeb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca13e9df-d9e1-4af3-b643-6abe0595249a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ef4f50f-22da-4970-a285-fb59a08ef9d7">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_811fc7a7-11b9-40ae-bf3d-c80ae757d7c1">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b232bcc3-9258-4f68-927a-954e468595dc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c091db62-404e-46f8-95de-ca204e148972">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_526e1dd4-44f3-4914-8e83-0ea289dc65e5">D<xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_38c5aaa1-246e-4d6f-a0c0-5f7b2c16e130">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_80ec03bb-8670-4c5d-a38e-b4f5f52bb4ad">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30cd8858-cdcc-49f6-9284-cd2605a79fe0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f74e7409-4223-453c-8104-eff855141ec4"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_232d2255-716c-404e-b7fa-bfddfb01c0ec">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae4fa0a5-678b-47f5-8abe-910be2bcf65e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ff7cd08-4383-45b0-a4e9-5516e0637a2d">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa35adcf-682d-4b9b-bb4a-c6e69bb38830">UIDREF</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_615f597c-ee33-465b-9d58-b8466b7ce731">EV <link linkend="DCM_121126" xrefstyle="select: nopage">(121126, DCM, "Performed Procedure Step SOP Instance UID")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bb58733b-554b-4df1-ba64-b552b61a247a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cb70c8b6-dcc8-4b9c-bcdf-ac162ca36bc8">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bcdbd5ed-1384-4784-9cd6-3732d7500761">IFF a Performed Procedure Step SOP Class is used to provide status of the Procedure Step</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3122427-a097-427d-960a-17856061619c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b15ce7f-5723-4674-8fbc-f61ec6d8146e">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ab5888f-f251-47cb-ac0a-93cd51e3d836">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50648488-abf3-4661-bbaf-0856f79bee18">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7f387b2-9579-42d3-9950-877cd551aafd">UIDREF</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6e92386-07cb-40e0-8ae4-cd318430f89a">EV <link linkend="DCM_121127" xrefstyle="select: nopage">(121127, DCM, "Performed Procedure Step SOP Class UID")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c83499ff-fa4a-42d3-926f-16cae325170f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_23190f32-dd25-4766-ac35-6c10e6c549ca">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f7ef057f-2845-429c-b1c0-af761fe05c8e">IFF a Performed Procedure Step SOP Class is used to provide status of the Procedure Step</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f8e4b22-8f9c-4c79-8f08-b8ba71be5d06"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_45aefb23-fa5e-4fd2-a586-bbf144f2dd33">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3802248f-b32e-49ec-ab2d-6dd0cad3074c">Row 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_291f2d09-89fa-4de2-9098-c4defd2f87e6">The value of the Procedure Action ID shall be uniquely associated with the step or action within the context of the Study, and may be used to associate various Procedure Log entries with the step or action.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_90517740-bd85-45c3-9b89-d16982282887">Row 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c0bf63e-1140-44d2-be0f-600fac90c644">May be used to record the identity of staff roles for the purpose of this Procedure Action, which may differ from their roles in the procedure as a whole.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3101" status="3" xml:id="sect_TID_3101">
                <title>Image Acquisition</title>
                <para xml:id="para_c32b3845-27c8-467a-bc62-c3159f1cd074">The Image Acquisition Template allows recording of the essential parameters of a digital image acquired during the procedure.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_0f985e8a-294a-4e7e-a2ff-22f2e34d46ba">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_921db2f5-8c00-4809-86d0-42c805e3e45b">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ed0ba04e-b089-48e1-bea3-af301e2a8bb9">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3101" rules="all" xml:id="table_TID_3101">
                    <caption>Image Acquisition</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_10cb6a10-ed16-4deb-9b9b-7a1cb070a7d7"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7af8ef32-e7cc-4f79-b633-f23e9d03dd96">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_987b49f4-935e-45d7-af95-c0078b313f70">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3158d279-0fdd-4d9a-a01d-4cd805ec1dbd">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eaf104c5-8a08-46f6-ac2c-45321e62cf14">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_63bcbab5-d232-4fb0-b478-83333e384fb5">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2227775d-fc72-4e23-8759-68cca47c8f10">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ccb381be-c983-4ca2-b89e-2e6d4f0258af">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_631cc9d0-f13d-4091-824c-385e1d10dbf5">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e44c60ca-ca3e-4509-96bf-f8448a5af3a5">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d889441-1b18-41f7-9ec3-f091913a7d7c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_177d40e6-0b33-482c-b360-4b00f27761e2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57adf028-737c-47c7-b248-94c9a23ee6ec">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30dc5606-259a-4c53-88b1-8b177fac7375">EV <link linkend="DCM_121138" xrefstyle="select: nopage">(121138, DCM, "Image Acquired")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_086de62a-79f5-4c4e-9b60-818231ac3875">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7d219abc-8f21-4d6e-9cf7-7f553d8fa04a">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58034dce-6f89-42f2-84d5-782567310ae6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_819a3675-3b5b-40a4-948e-874cbe1187d3"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0fd4b794-6eba-4fed-836f-cc88a2f0d122">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46f19ba0-3dc7-4450-8205-64ad76682718">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96a6ee5e-a765-4f3c-a740-adea4e4e5c1f">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c20d1fa5-c4cf-487b-9e82-d9736c0e5379">UIDREF</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70edce4d-05eb-45b7-bd6f-80f803ed16b4">EV <link linkend="DCM_112002" xrefstyle="select: nopage">(112002, DCM, "Series Instance UID")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7503c581-8264-46d5-946e-138dea15b45b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0092d9fd-08c2-4e3d-9c59-2e2c4bee9bc7">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_661a042b-9793-49c5-a529-9e3c8babb344"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02f7246d-d7b7-41a5-8157-9f549eaf9b16"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4beed909-8b0d-4843-853c-c70a1bf93f02">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c862948-9b20-415d-9841-c2f09306c780">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_224b9147-bf5f-4f9e-9703-c288e00219c4">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de392374-ba7b-4d4a-8a28-b1aeb1f8a165">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4554e3cf-bd29-49dd-9f17-26d4c1378829">EV <link linkend="DCM_121139" xrefstyle="select: nopage">(121139, DCM, "Modality")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fdc5bd98-a0dc-447d-b71c-6305ea48b8fe">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d5e33784-92c3-4a39-9459-782ca4d643c1">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c329cdde-e1e2-49f1-b373-d8ad75529ca4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_468cf061-0118-4834-9769-8d675f864650">D<xref linkend="sect_CID_29" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_72b7ec69-adec-400a-a799-bf6ad2649903">A code derived from the Value of Modality (0008,0060).</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a1aa1436-512b-4734-a476-1fa4900436ab">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad6b099f-1406-4346-9613-16e3eb0ffb21">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9becae6f-5102-4225-832e-a0f896503652">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_908aff89-aa17-4c9c-bd52-6b84779b2f5f">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_32829f92-d8ca-42f2-aba4-791bbf3bee59">EV <link linkend="DCM_121140" xrefstyle="select: nopage">(121140, DCM, "Number of Frames")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e3ca2261-44c7-4549-a1e0-5b6b5bd904b8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ed1dd0c9-76f2-4ad5-9b43-2287ecd1b84e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_20200de5-7ea9-4b20-adaf-b0d71260bc02"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38197803-1b10-40e8-8ec6-342a1e5652a2"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a1abb64d-5577-4926-8062-7e5537b5f62e">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0e406d8-7408-400c-b2c9-0e2c3df34b35">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8d9eef3-f4eb-419a-87a9-385fc3b74fb8">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3412624b-c97c-4015-b5eb-469ec2916495">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9bf74bd5-aae3-4324-bc94-3156da4c75eb">EV <link linkend="DCM_121141" xrefstyle="select: nopage">(121141, DCM, "Image Type")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_440ee1af-9630-4d7a-b13c-e8f52593b83d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c6253fbd-799e-4b56-bd7d-6e349446f7dc">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5259de95-10c0-404b-ba3a-515bcd263fd2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6469a60d-9141-415f-9d1d-98bf21a7b74d">From Referenced Image SOP Instance (0008,0008)</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c843559c-9d5e-4e83-81bf-e283a50d4001">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73e00536-cd63-4282-8b4f-1396d872cccb">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4bedc660-101a-4159-a114-ff9d771e4b0e">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2f9cdd5-e356-45c7-bf67-81ab3d1ac2c0">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_056c4c14-70fa-4252-93be-7f20f3d464b8">EV <link linkend="DCM_112011" xrefstyle="select: nopage">(112011, DCM, "Positioner Primary Angle")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_493867a8-5962-4eea-bbcb-d57dd2514563">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cbc2fa84-604e-4213-8b4c-6eb6812f8ed5">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a1deac85-5cb9-468a-a18b-9260b7b4d081"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59e9849f-417e-42d5-ae94-f39a9dc121d4">UNITS = EV (deg, UCUM, "deg")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04095599-992f-42c9-833c-93f4d94038d1">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fdc9bc44-476b-40f2-9770-671d4a0d59ff">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51f282f3-177d-40ea-8bb6-ce4901eff132">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_216ce616-8aff-446e-8243-fc53c6050c35">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4d9e1ee-8167-4c2f-8d7c-4310a2307417">EV <link linkend="DCM_112012" xrefstyle="select: nopage">(112012, DCM, "Positioner Secondary Angle")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_507cc233-0770-42a9-a007-84d6733f9c9f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1087d465-b8f0-4319-bc54-c97ffc450e98">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_12f8b55b-04b7-4a23-a36b-3637063930c6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4173502a-3795-4d86-990a-862cce7bc4e6">UNITS = EV (deg, UCUM, "deg")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_251d3de0-b95e-4e8c-aab0-200b8f548982">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63bc96e7-1d85-4f9f-a581-eabb6ab558f9">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_064955fb-1c5c-46f3-8153-10e14675f7b3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6aba1818-7fdd-416b-9ba4-b4922eac6880">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ead80ce-369f-4fda-b9a9-4dc8d77a1870">D<xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1f43e96d-0bc1-442c-afa8-20c2b4153821">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4888d1b2-fce9-4c0a-a908-df0c91826b1b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8eed7121-a58a-48a3-aedb-f2337b145fa1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06d5db24-86b1-4925-a4a1-c2e41d7b567b"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3102" status="3" xml:id="sect_TID_3102">
                <title>Waveform Acquisition</title>
                <para xml:id="para_60f0e2cb-5088-4497-a777-5c7a3825d358">The Waveform Acquisition Template allows recording of the essential parameters of a digital waveform acquired during the procedure.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_11b44a70-babb-44ab-ad1d-91e1f97c279e">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_bf42a775-2635-4a15-bbd7-9b952e87145e">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_eedd6225-2777-4d18-a108-5e7279c07c8a">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3102" rules="all" xml:id="table_TID_3102">
                    <caption>Waveform Acquisition</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d7843456-b08f-4198-a552-dab19447edba"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9fe711a6-47f1-4e0a-8109-268c475b1767">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_569c2eca-1c32-4220-b187-e7986b280fae">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_baba85a4-2368-4e1d-afde-cf27ca57e0bf">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2b4be3b2-0262-4f63-a43a-378722ed1632">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ceb35d61-fe94-49d7-9ea3-34dbeb797591">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3652d2fa-2c6a-414a-b9b4-9b881c823925">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ef6c7063-ace9-4dc6-998b-dc4c14f3d0b9">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7841557a-8c01-4862-bea3-e642bf562782">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4662d414-605e-454f-b2e6-bb42d6c0295f">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5640e26-7200-4195-9df0-829924f3816d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_95bd75e8-b785-46a9-81a5-fe04929e1616"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69f78c40-8aa4-44b3-9459-6a28bced6920">WAVEFORM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9233369d-9355-4170-8858-4e136428a9e6">EV <link linkend="DCM_121143" xrefstyle="select: nopage">(121143, DCM, "Waveform Acquired")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_824f4dfb-6dbf-48d3-8dcb-715c69997d04">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2a62d448-8ea7-4ba4-b337-7fe3582258ea">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9f083a2-d5b8-4893-b980-0fe217d4af0e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4da8ff1f-fca6-4767-a812-8eca3dd99c25"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0e54160-8ac8-4f03-bd9c-b35604b12d6f">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e811fa44-f666-478c-ab19-89f16816fc1b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7386ec7c-f6a0-4b00-a333-19a5a6f52012">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb3126de-5f0a-4ce0-af52-d7f6bc767f9a">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3562a117-94ae-41b9-b400-02e6c5c9b8ec">EV <link linkend="DCM_121139" xrefstyle="select: nopage">(121139, DCM, "Modality")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_881cf82e-5568-46ed-ace1-b0729ba8d445">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5fefb518-b01c-4d12-8a22-25b8b9164815">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_afad61b2-e06c-45c1-80b5-3afdd788fd32"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_140c9348-c60c-43db-b568-dd4866267e53">D<xref linkend="sect_CID_29" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_5894365d-5020-4cec-b803-6200f8a5fe06">A code derived from the Value of Modality (0008,0060).</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa8facfd-60c2-4de7-9deb-c428a53695a1">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_411972de-b0f1-47c1-8094-56dc25d9eb9b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_326e369b-b9aa-4759-b18c-0417a270471f">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7a28851-723a-49dc-afbc-5d00810b2870">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a8edd80-55e3-4490-8fb9-272b78a1fb1d">EV <link linkend="DCM_121142" xrefstyle="select: nopage">(121142, DCM, "Acquisition Duration")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9d799555-9570-4773-bbab-f1afc7830b2a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d79531db-7cb1-4891-a860-8cbfb56cbdaf">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67502558-9479-4173-a422-710c86e43948"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1b5f332-bab7-4560-ac9c-6ebb01d288fe"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f39f009-b1f8-41a6-98d1-a319239e8b25">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1fb4a898-09b9-43d4-84bb-9e521d6ef2ce">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2641d2b8-4e8a-4f0b-939e-289c1db25cb5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb05a9b7-0166-4d2b-b0a5-ba52a93805e5">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd51ef52-5791-4b97-bea9-435aeea36300">D<xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cd3aa39d-27ed-435a-addc-6b59c7add89e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7c9c4897-308a-4320-9821-c6d173ea556e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a2ecbcd-30e3-46f1-becf-488ee8e9208b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1cc95480-522b-4f8e-81bb-4c71c4ac58c4"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3103" status="3" xml:id="sect_TID_3103">
                <title>Referenced Object</title>
                <para xml:id="para_a89976ad-3893-494b-8488-6b2e5805761a">The Referenced Object Template allows reference to measurement or report objects, such as prior medical reports, laboratory results, hemodynamic measurement reports, or quantitative analysis reports.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_fa378906-d8f3-4b76-abde-c97df3695fc9">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_10f72c3f-0bcf-4be7-8dce-d0cdb94031ce">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ba956baa-f69e-47c8-9ae6-b0b4756c5774">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3103" rules="all" xml:id="table_TID_3103">
                    <caption>Referenced Object</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5fb0f5b0-4f0f-45dd-badf-8f2238145361"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_911bf402-2d96-400b-8e80-6e2fededb7e1">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b53953a-6ab8-4a89-b511-8bd8132deb01">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_623e8a1a-3b98-4349-becc-3ef91f218089">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ea910843-c702-4776-ac6a-522a317fa5fe">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c5a3e3f7-87c4-4fc1-bb67-04d131688ae1">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c24a5fd4-2aca-4766-841a-4674c6c26383">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_865b4504-b98b-4338-a0e4-c158aff55bd1">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ee9388d4-b15a-484b-b338-5a828053ef65">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0554b81-5f39-4488-81f6-1000e6b74dd2">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cfd1f166-d27d-4a15-af36-e604ea0fd974"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e0754d62-4c66-4d2a-b9be-be8bc2bb08b5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ac58f23-83b4-4dcc-9df6-a6112175d003">COMPOSITE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_95886caa-396d-4b29-a387-545b102ef7e6">B<xref linkend="sect_CID_3407" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5592b84f-f860-4dcd-9089-331b360cff10">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_558fb986-e628-4ee8-965a-6dab21479082">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92eb24bb-9b4c-4000-bcc7-e9542ec3a82e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_abb758e2-6f1a-461b-b8ef-bcb1652bb9e7"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad4e4c22-564e-4d16-8b7b-27e6885607b7">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1ab2d3c-9670-49bf-9a99-47068a31904c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67770482-73fa-466c-9ad3-21465eedeecf">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26cd2eae-780d-4fa1-82b3-53ce46e7c59a">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6619a252-7def-4e2f-8189-9c6145c2b2b8">EV <link linkend="DCM_121144" xrefstyle="select: nopage">(121144, DCM, "Document Title")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8cd6d689-ba96-473e-8659-4587ac4e7d26">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bd5e0969-955e-4a83-87ef-82504392dead">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c43f5c0c-1442-4fd6-9edc-cd794b017a73">IFF Row 1 references an SR object</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_faa0e734-64d0-47bc-b2fc-5d01009f2819">Root node concept of referenced SR object</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf139c37-c103-469e-8197-2f10863f81f7">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee001fcb-51f5-482d-bbee-737a5bbfb5d1">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_346ca08a-a9fd-443d-879b-f7a067c7b3ab"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f9887ff-b935-4470-9179-6fed7b6f8a09">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7bf99e58-511c-4554-be13-25ffdf9c9d02">D<xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf6da03c-52c8-4d51-a40d-ea930c064000">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_acf7a09e-cdb3-43ae-bf41-0e2dcb33f30d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9198c586-bd76-4271-a337-406861f6d4aa"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b85e88d-be6b-4301-b76e-54bbb98c5a83"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3104" status="3" xml:id="sect_TID_3104">
                <title>Consumables</title>
                <para xml:id="para_1ed6aa3f-e0a3-40bf-b9e3-b15b4b3c8c6b">The Consumables Template allows recording of devices (e.g., catheters or stents), drugs, or contrast agents accessed in a procedure. This Content Item is directed towards inventory control and billing. The actual clinical use of the particular consumable is recorded using <xref linkend="sect_TID_3106" xrefstyle="select: labelnumber quotedtitle nopage"/> or <xref linkend="sect_TID_3107" xrefstyle="select: labelnumber quotedtitle nopage"/>.</para>
                <para xml:id="para_8afdda1b-fec1-47e3-9ced-09b4199204e0">This Template allows recording both consumable retrieval from, and return to, inventory or stock, and disposal of used material. The quantity involved in each recorded transaction may be specified.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_8af0dc0b-9f0f-4662-8e1a-c10b5f46c5e4">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_d8600757-63ee-4adc-a9cb-1ad89e9cb149">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_9910e13b-6487-4ca9-839b-811eb24f062e">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3104" rules="all" xml:id="table_TID_3104">
                    <caption>Consumables</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b8e4dc6e-a530-4127-866f-18582492b354"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0fc986db-844d-4a85-a8f6-453c0c7cb2de">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8343291b-4f48-4648-91ac-8354350b6c73">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c33828c1-4367-461b-91fe-9fe05006cb64">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_771f0d3d-5583-4241-9754-24fd39128bf5">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0e7d5f2c-fe40-497b-8dd9-a7bfc0e71633">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3750bbed-8787-40ec-8dda-0817d913c82b">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_af53bbbd-fca6-4ec5-827c-6fcc784b642c">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f51bf3b-9977-473f-930b-f53c53a2289d">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84e8f065-0e37-40d1-b001-a63703f9bad3">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_985681d4-bb48-42ca-aa5b-5cbdbfbfabd5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_346e118c-a557-466d-9825-fcb8b07f04f5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0609eef3-198c-4d66-bb57-12a5ecaa9555">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_073adcd3-c4b1-46a6-a974-2b1119aba7fe">D<xref linkend="sect_CID_3408" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8fa48682-0867-4a18-89d5-c738b1784706">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_638387e2-5c9b-4b1e-9408-776afcb396cc">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fdf0df4a-2443-4176-9dd9-a285d0334023"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_468cd5c3-05cf-4efc-9ac9-0b1f5c07a689">Vendor or local bar coded values</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d4e49d0-9682-4238-96fb-192e2342fb77">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_77113ab9-0132-45c9-85b0-60d0eff472c5">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5cf66500-32f5-4d06-b891-0679a462ed6a">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0fea1479-5393-4312-adb6-300e6af8b30a">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_131a3178-193c-4e4e-992f-cd87f1450bf0">D<xref linkend="sect_CID_3426" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_338b262f-fd8b-47ef-88f6-5c0e64fe387d">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fd7c08aa-d521-4ffa-ada1-cc1d2faf1c7b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c6f54c8a-d5d9-4bc5-a191-bc4374769d5a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75148c4f-3a46-4b4e-a0e5-6139f31384e5"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0fbf247-0532-46f0-9735-5d752c78710e">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a535b06-11d0-4426-8b80-030949f85a4a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a488e9a7-5614-4058-b94d-4ff3e7ccdcd3">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8b38306-9f30-45aa-9674-352e7c8090db">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_adef956d-7597-4831-b042-a6cf208a5680">EV <link linkend="DCM_121146" xrefstyle="select: nopage">(121146, DCM, "Quantity of Material")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c79bb662-c477-403e-82ad-841bacb34103">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a4bb6b62-e0af-4d83-8ce2-89d2e104b71a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e249696c-d130-4b4f-8d15-363f1ee4bc1e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85706501-f499-465a-b9ea-78111add702d"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62b004ab-517b-42ec-911e-53a7453d115b">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5536f2f8-7ffc-47d6-bb85-d3ad30f7cab9">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4fa00ae9-f1ae-48de-ad45-70fde6e3deef">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_369d5778-d82b-4380-928b-1a50b222a577">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d88727c-4a00-4b6f-a020-4b8c992e7451">EV <link linkend="DCM_121147" xrefstyle="select: nopage">(121147, DCM, "Billing Code")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f353d7ad-26d1-486a-86f7-b8b39fe5be67">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_93d7a393-f413-47a3-8189-4c5321ccabff">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b67ebefe-e863-43aa-8254-f6d5d364b1bd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4763bfdf-d8b7-4733-9dc9-8aaac3248d2b">local billing codes</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_285ed023-31a2-4f6e-ac3f-778a44579b72">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0552606-63a9-4798-aa36-f34a35913b6a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58101abd-bff3-43cb-8d88-e6dd25be4363"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06a70858-ae4b-4cce-82d0-a5e5ade15e64">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1c7c03d-cc10-403c-913e-1f5ab381abf5">D<xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0a9d6181-8ea7-42c2-8761-fee2a965b2a2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc9e86a8-c8fb-4c42-b1e6-c752f42fa466">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b960ab83-9901-4948-a7df-bf2a881da9e9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c2f272be-efc6-451a-98d4-7eeb9e49d0e9"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3105" status="3" xml:id="sect_TID_3105">
                <title>Lesion Identification and Properties</title>
                <para xml:id="para_ab869788-8783-4a0f-9c55-1ffc8d4402d3">The Lesion Identification and Properties Template allows recording the identification of each lesion addressed in a procedure. The lesion identifier may be used to relate diagnostic or therapeutic actions with their target lesion (see Row 4 in <xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>). This Content Item may include the initial visually estimated measurements of stenosis or TIMI flow; measured values from a quantitative measurement report may be referenced indirectly (through <xref linkend="sect_TID_3103" xrefstyle="select: labelnumber quotedtitle nopage"/>), or by quotation (<xref linkend="sect_TID_3109" xrefstyle="select: labelnumber quotedtitle nopage"/>). Subsequent (e.g., post-intervention) stenosis measurements may be encoded using <xref linkend="sect_TID_3109" xrefstyle="select: labelnumber quotedtitle nopage"/>, with the Lesion Identifier conveyed through its
                    subsidiary <xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/> Template.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_2f2f9ab4-2ba2-4cee-bad1-57b79b6fede1">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_692237dc-400d-4add-9ca9-b942464eccf2">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_aff3d3a2-0ae0-4c36-a2cd-419a2dee9daa">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3105" rules="all" xml:id="table_TID_3105">
                    <caption>Lesion Identification and Properties</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ad6541f5-918c-4654-acbb-592c34fdab4c"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_667c69f0-2f85-4319-a6ce-20282dd9ba8e">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5d89f2a6-9303-4f65-b285-3a5311b979f3">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d12fb36f-68ab-46a6-8a0c-4e40f763b7eb">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9c4fa875-7798-4829-878f-dd3d0fda0f6d">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2226618a-3dc7-45c6-8e63-031fa8a5e049">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3d6c7382-d37b-46a8-ae13-9e6a51801d00">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6a2be74d-c26d-4fc1-9f7a-947f858b0b9b">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d00fbc6-e24c-4c14-99f2-2e09a6e69588">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9cce9b4a-44aa-4525-87cf-666f470336a4">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f89a2bc5-1601-46d5-9c70-a3446ffa4ae8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d567b2d7-2922-42dd-ad8c-c1b424f2ae55"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d954c99-e75e-4801-99bf-d8666d7b11ee">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1982e46-2f5f-438c-a9c7-c0a4e7b1feea">EV <link linkend="DCM_121151" xrefstyle="select: nopage">(121151, DCM, "Lesion Identifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b13700d9-0f3f-4244-b374-c3ddaa5b9232">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bfdc1ae0-97af-475c-8d76-718741541b5e">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ed5fd96-d155-4d5d-8a8e-d71d42c71d8d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e125d5b5-2c25-4db2-a9e1-8ec07c3f84fd">Up to 3 numeric characters</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab629b0a-7dcd-4b1e-a4a5-8d38d586d810">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af9668d2-6182-446b-b691-18111c9a44ed">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5536e4a-c3c5-4740-b1fe-0a00a4290916">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09a3da83-9a20-4c92-9d29-baa05cab4407">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e1ff5b85-0387-4b2e-8c7b-bb0964c99e49">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b980dcaa-e0ad-4b01-ad4f-4c4bf7b7f3d8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8a557b75-5c59-48ae-915d-f63ae2daebef">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9553765b-9d03-45e9-8f6b-847ad0133a7e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_995cde88-4d53-4fb4-a90b-1c41b1b085a5">D<xref linkend="sect_CID_3604" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_01930633-269c-4a56-99b5-907712800400">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b40f3f4-cf7b-4e35-bdd6-05bead2a9a47">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d0f16c9-38e3-4307-8012-07375feddd37">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_53099abc-ae8f-4138-9452-d62514f47513">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24abc45a-ee5d-4071-bc75-22df607b02e2">EV <link xl:href="http://snomed.info/id/106233006" xl:show="new">(106233006, SCT, "Topographical modifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e00fe9a5-f5e5-412b-8edb-8bae56530827">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e1b59539-e726-4385-8bbc-1594a3c7a41a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37af36a7-5123-4222-9604-fb2cc6452a17"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98bc6005-5738-43b0-a347-8aeccd73fce1">D<xref linkend="sect_CID_3019" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9440e0a7-e986-4b49-aebb-e4df9069ade5">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fef79c82-5281-4ffd-b807-0de898927664">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09bd253b-c611-414b-bffe-4a8233ef0ea7">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_23ea514f-ee14-4c83-a289-b1092054ba1a">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fec7fc10-35cd-4c56-a07e-3c15773627ce">EV <link linkend="DCM_121153" xrefstyle="select: nopage">(121153, DCM, "Lesion Risk")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d4104879-864f-439b-b93a-9102c182053b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_486dbd2e-7293-4ee2-b6ac-700ef62fce8c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd76a427-b289-459f-9444-e4d40143788d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8cae7d24-8776-407d-8b93-43b30371f2f7">D<xref linkend="sect_CID_3418" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb7b98e0-c428-4ced-85ae-42eb0793df6b">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b445848-fbba-41ca-8c44-e488b1329d5b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_641ad3b5-8aaa-4bdd-9083-7c8f45d837f2">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c791604e-3480-4315-b407-989289240403">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f5b02da-2d58-44ee-b439-ba496656e6f0">EV <link xl:href="http://snomed.info/id/408715008" xl:show="new">(408715008, SCT, "Lumen Diameter Stenosis")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a7fcdb86-deb4-428e-b681-9bf22ed4e2d8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a011a091-72d2-43a5-b8ca-a39d1067b8fd">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6742467a-babf-4d9f-9e63-56c69cf1f3cf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58f54c4a-6512-412e-85be-cc4fd068028f">UNITS = EV (%, UCUM, "%")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e230798b-bb4c-4251-9044-c529582c5115">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b1e6ac8-0864-4403-9a54-afb90c353e1d">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4231e58d-c30a-476a-b029-a0a69c714a28">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5af5f9c1-6252-4802-b825-d730062c7c50">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5bbf6b6e-098e-40cd-8aed-311c86042de2">EV <link xl:href="http://snomed.info/id/129085009" xl:show="new">(129085009, SCT, "Catheterization Procedure Phase")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d5d84407-795b-4f34-9bc3-086e1583839e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_25243c72-69bc-4f9b-aada-b2101aebe434">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b742df5-a28c-43c2-9b58-19264e3ea87a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae344623-5098-452b-9578-09325dfdee27">EV <link xl:href="http://snomed.info/id/128955008" xl:show="new">(128955008, SCT, "Baseline Phase")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b075a4b1-a37e-4c73-a2b6-a4ac090cb22e">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f69542e-9888-4c96-904e-b1da78fe3c1e">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a07cc684-6b23-4499-9993-df4a6b982182">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6df98c1-f478-4174-8c5e-1b6186bbab2c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_053f5c4c-7ff6-424c-855b-035fbd2bd04d">EV <link linkend="DCM_121401" xrefstyle="select: nopage">(121401, DCM, "Derivation")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_90ce7936-e9a8-4abe-ac59-ec235a267ad4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f173d994-bd0a-4f65-8a53-a5b114775435">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fdeb442f-df55-4b5d-b583-e5cbd3c27715"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8164ea7e-400f-4e9f-b06a-b5a06da3dd80">D<xref linkend="sect_CID_3745" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d458d7c7-7894-41ae-8d61-ea5f5f54d18b">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43159830-ad38-4130-86f6-1e9918b2aeac">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d86e9a9-ee07-4e13-82b8-0cfed80137b5">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2dabd2ce-6a9e-41e1-979c-e8dcdbb7610a">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e078b71-ee5e-4518-a64b-e52d4b781c6f">EV <link linkend="DCM_122109" xrefstyle="select: nopage">(122109, DCM, "Baseline TIMI Flow")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ee189b1-8b61-4e19-9b62-08e68ae3c5ff">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8173beba-4d4c-4558-a03c-135082d8ee79">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_962ddc7c-29ec-4a64-9629-82773aa9b8c4">IFF Row 2 specifies a coronary artery</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2512904f-a61b-4903-92d1-b5ef59826b0f">D<xref linkend="sect_CID_3713" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d489017-a044-4ddc-8409-5fee9bf1df96">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c05f1626-d69d-40b4-ab95-316f0c6122db">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_228f3b35-d96c-4b98-8d10-29f2e470812f">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99bd9054-0cc7-47bb-a8ea-a0ef062523fe">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88351a5e-4c23-474e-a682-41b7c17ebedc">EV <link linkend="DCM_122131" xrefstyle="select: nopage">(122131, DCM, "Degree of Thrombus")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7a98fa1d-1140-4086-ab45-48fabbc8b836">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a441840f-c341-457a-82fd-bb95da3f927b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_20b747bd-ed8b-4b0b-bb4d-dc7030781184"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7258734-bc0e-42e2-9c66-0905df2971f1">D<xref linkend="sect_CID_3714" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59965aff-bae0-4d20-9d0a-476494f64726">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_840586c9-3233-4709-b907-cd9c553c1c90">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36c70210-00ea-4165-b763-0cb61d277a0a">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed94436b-c34a-438e-aead-c3a7f68ebb5c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6758ae3-f7ad-411e-b0fb-17d48b61255f">EV <link xl:href="http://snomed.info/id/129737002" xl:show="new">(129737002, SCT, "Lesion Margin Characteristics")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_49baa51c-7bf8-482c-a07c-d2635399c504">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9fe39335-17ea-4b11-b20f-7a6caab1bde7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f35d8af6-6206-4b92-abfd-3f8ea670d5f8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e76354a-3837-469a-ba1e-f8cee5bcbdee">D<xref linkend="sect_CID_3715" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fabdf388-7954-447e-8f5d-02fb0ba0ccde">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b50f99aa-0366-42cd-bde5-ea6cdba19b30">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0943f7f0-d59b-4f49-8d02-ab4f3dc3054b">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38046142-e6e8-4cc1-a5b4-5e3cfc075dcd">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b7b5f49-3845-4579-889d-b01037c21cdc">EV <link linkend="DCM_122134" xrefstyle="select: nopage">(122134, DCM, "Vessel Morphology")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2b533600-8023-45d6-85a7-d41b6b671d81">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2ac1c3b0-9da0-4cc4-88da-242ed15300fb">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dff4f4ef-710e-4ace-a6e4-f688418d12d1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac7b188a-6a45-4032-bffc-ff5a9d0adb1f">D<xref linkend="sect_CID_3712" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af59b414-6ee3-4e0a-8672-adf44ef5874f">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4088ee61-6bf1-45dc-9f66-f65cd1dd3265">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dab952c2-7a1f-41ed-851b-fe407b80d50e">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cfcd04b7-3f2b-4707-9d85-200004abfb3c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86a7ba90-ec0a-43e5-b2b8-febaf8d3e056">EV <link linkend="DCM_122132" xrefstyle="select: nopage">(122132, DCM, "Severity of Calcification")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f4ea4c4e-398d-4248-aef5-b2f0b794994c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ea0b848f-d1e5-43c8-85d6-a037e4b4fbee">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b971d495-853a-464a-834d-e2d0c573b6d8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_380d7385-c0a3-4465-a807-c6a4c42b3b87">D<xref linkend="sect_CID_3716" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f708237-5151-49c1-9489-3bb99f9fe494">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c3e99c0e-7e90-49c5-9859-83605b8783f2">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86615690-923f-43dd-a58f-c8ce7468ed53">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf5408da-08c2-4f05-9400-c8e52d641912">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1374bbe-e1e8-41f1-8024-cc7239650e2d">DT <link linkend="DCM_121080" xrefstyle="select: nopage">(121080, DCM, "Best illustration of finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fa920966-0501-4e83-b4b3-c0f97c951f79">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_47598655-fda6-436d-a91e-2f1a999b664a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d71da7eb-17e6-4d1a-bb86-1c085d78f887"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_76b5c6ae-f142-476e-91ae-eec08eca0af9"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_41b5f4af-93eb-4f1f-a50e-fca07cc8c6d9">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d4b42c02-ea75-49e8-9c55-13549a31913e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_95808ef0-3210-408f-9e27-a619c84da80a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_afc47127-742e-4bb3-87ce-3062112d9fdb">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_19e9a5d3-78f1-49b2-9b14-313b09012228">D<xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_adc82d95-825b-491a-8bb4-aff900f4b50a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9f86c370-4fbc-442c-bc26-82ace3fba927">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98ee3f0b-49b7-4b89-9f81-679b1a7661c6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5f0b04b-c49b-446c-9045-22b18019412c"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_74bbd6ad-3149-4aac-97fc-3c9889bef3c2">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_747e7445-b699-4efc-a631-171e2f41882a">Row 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0d768ac-c613-4f15-b711-aa5aef063099">Lesion Identifier is specified as a numeric text string in order to facilitate transcoding to DICOM Attribute (0018,3105) Lesion Number and to formats for outcomes registries, such as the ACC National Cardiovascular Data Registry™.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3106" status="3" xml:id="sect_TID_3106">
                <title>Drugs/Contrast Administered</title>
                <para xml:id="para_0e3c7e81-abea-40a1-b822-765a6aac7e35">The Drugs/Contrast Administered Template allows the recording of the start or end of that type of event, together with its parameters. If start and end are represented by a single log entry (e.g., for an injection), the concept name "Drug/contrast administered" shall be used.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f207fad7-5cd6-4fbd-958f-eef2810ddb98">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4d1407ac-75e1-435b-bc83-a2e3691e87d6">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_a42fee8f-5971-4b5f-9c18-234b67900df0">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3106" rules="all" xml:id="table_TID_3106">
                    <caption>Drugs/Contrast Administered</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1cb639a6-cf29-4bd5-9ec3-7d3ade29e4fa"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_de5251f9-e5a2-4ec3-bebc-de90bcd809fa">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3b198056-98ad-4e70-9e05-5b1848cd9174">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a9084837-511f-47e7-be42-110406e1c9d4">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0dbcf1cb-6b3d-48cd-9d58-f23cb15dcde2">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_703905f5-cd26-4858-8060-13291ea4a544">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_84006a71-f75b-416e-898d-af7053538610">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_87e996f1-ab4e-4a00-9aba-212170a7f515">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f69957a5-bf56-41cf-b485-5c7a37b3cfa1">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_78793426-0805-4a10-84c1-8bdf3d6030a0">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e58c7e06-7dee-4473-af39-c649a43139f6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ff4a4ed-be4a-4226-969f-1a8bd8ef2fd7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58cf7e1e-1c86-4d55-9e20-f6517b05b2e7">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e0cf2368-2532-4565-891a-a8b840ba870f">D<xref linkend="sect_CID_3409" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0e49023e-f249-4de1-bfdc-442e58c9de06">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4dbf6391-c81f-4a07-a8d7-7ade4c9307f9">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83b68c02-fabb-4e22-84f5-ba7e2e167828"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b9ad0fab-824f-4ac7-8de8-2bde09ac58e7">B<xref linkend="sect_CID_10" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_6ddb90b2-8478-431b-a41a-c5af05787aec">or</para>
                                <para xml:id="para_f356eb69-32ab-4fae-823e-5e48d5967e84">B<xref linkend="sect_CID_12" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb60c079-bb24-4356-8e24-9d6fcfe5ef75">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a3db2f8-13aa-4319-b12b-04d72aede37f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a280ece-7cb0-4f51-94c1-ee34aab11455">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b43babb-9944-4f1d-9b64-8b37c879cef4">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e5e52f7-467d-447a-8211-873c743276a7">EV <link linkend="DCM_121145" xrefstyle="select: nopage">(121145, DCM, "Description of Material")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_98b794d3-63ea-45b7-af51-02f6ad3b714d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_88b935f0-2760-47e3-aa89-b3c4c222695d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc0d5bd0-ea58-4652-b4f3-47a124f3b095"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_853fd015-db39-4d5e-b207-563af3a1b3c0"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d110bbb-2779-4c70-a8ee-80b1cdaa25b9">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dce5802e-3695-43c0-b1df-6de46b460cdb">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aef3c39c-55d4-4497-a7d5-4baacb1f449f">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5edafbf2-dd10-4aa0-a35c-224a7f4a5db0">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f93291da-8692-4043-8d0c-ac4279a66be8">EV <link xl:href="http://snomed.info/id/410675002" xl:show="new">(410675002, SCT, "Route of administration")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8fb118a5-a2ee-42dc-9618-c698c92f9154">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_be131673-32f0-4afe-aed5-4aab56807566">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_28c8b859-2c5b-4fca-bc0f-4d7047549342"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69258536-993a-4490-bef6-810c1054b2a6">B<xref linkend="sect_CID_11" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a59d5ba-691b-442c-ba68-144dc2246dd1">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_abe8bd37-44d6-46a3-b0ce-e84dc3d94dd8">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7bdc8ce-33b4-4517-b185-960d6ffadda4">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04a22138-ad6a-4bcf-8cc6-69475c0c5520">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7794f1c-358e-47ca-877c-2c7f25877ead">D<xref linkend="sect_CID_3410" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_67662879-945d-41ed-ac0a-4a4f9e46336d">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_684fb290-0b4e-4e1a-81ac-8e9b783dab27">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dde1bf15-15b3-4362-bd99-995a71b02650"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4307771-95f1-4fd2-9fc1-f0f9aa910669"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d0e3ac4-f9d0-4e52-bfde-3ead82c33657">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0d691ae-d8b6-4169-ad43-b43523f2eeb0">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a731e3a-edd7-4299-a0c6-5288aaf2929c">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72acaf2b-dac5-49f2-b02c-5c8b1ca84369">PNAME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9567862f-03a5-4616-ad73-feea9f415dd1">EV <link linkend="DCM_121152" xrefstyle="select: nopage">(121152, DCM, "Person administering drug/contrast")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6a075902-c6a8-48c3-aabb-a01577914e66">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ff98e80-ee65-46f1-99f6-2dd6bd2ed0a1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a83d1fd-b10d-415f-8267-e0c63a7c2f91"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_932fa3f2-72ed-46a2-8cdf-b2f0c3a2646b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9354da9a-0614-44f2-a964-410924b3b48f">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c7d67d6-7278-4425-967c-246586484fee">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b09ad141-0706-46f5-8a59-62327559100b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e673b06-8227-46e9-bb03-eefc45f3f85c">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f763ec92-bcf4-4663-9876-9bac02426e05">D<xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_64c1a4bc-915f-4be6-bf90-6a252a1e4528">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a05018eb-fa20-4a5c-b8bb-b8250aac6ba3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3612b94-d839-4f0b-b1f2-6b7999511859"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_253f9f09-2474-4786-b391-653cc3daf7e8"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3107" status="3" xml:id="sect_TID_3107">
                <title>Device Used</title>
                <para xml:id="para_2eb7970a-9d78-4eda-acbd-fd92ec08f604">The Device Used Template allows recording of the use of interventional diagnostic and therapeutic devices.</para>
                <para xml:id="para_5c955782-b1d8-46b0-a18b-c92f5e2d7c6e">The identification of one device used to deploy another device (e.g., a balloon catheter to deploy a stent) may be described with two entries, with one identified as a deployment device in the Concept Modifier of Row 6 of this Template, and linked by the same Procedure Action ID in the Log Entry Qualifiers of the included <xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_392f84dd-49b8-4569-a756-5ae61b9633b4">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_6ee5b1ea-d8df-4e82-88e7-750c3f7e0c5c">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_d232c30c-4aca-4cbb-9530-3e2671213a5a">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3107" rules="all" xml:id="table_TID_3107">
                    <caption>Device Used</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b95fbb6e-87f3-4174-a2ec-55783c43a0e6"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ca481d51-6787-4537-a05a-3e1568a646f6">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_56574044-a535-41ba-a6c6-69419549dce6">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_43e5ab88-ac03-4fc0-8a54-d764712712dc">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fc00c076-f993-4f40-b689-c9518bee2338">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ec5e0f3c-97fe-43c7-9429-180f92be9ba6">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b6a811ed-d62e-44bf-aad2-3e6a8d6777f2">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_996b80e8-a2cc-418b-b269-f0feffe519ce">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0d849de9-ec8b-4265-86ac-8a76570da36d">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_539e1775-17d4-444e-906c-e701a9037243">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_975e81c0-bc31-41b3-938c-1257676bdc85"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea755c41-cf6c-4649-b56b-221448a3ee01"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f34f13ca-96a7-49d1-a1c8-f450635c880a">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8586b4c-ba2f-490b-8844-64311fbecdae">D<xref linkend="sect_CID_3422" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7abd4f50-93cd-430b-b204-910356f2a172">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f81372e3-b914-45ba-93bf-7b5a2c988dfc">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ed17b58-c594-4973-8d1c-da5997211a95"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a917780b-93dd-4f00-bff8-aaea4262460b">B<xref linkend="sect_CID_3429" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36d95618-353c-4283-9b03-46fda3209048">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cedf260f-db22-4cbb-97ea-5f88d3549222">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e14312a4-5d25-40bd-a108-35286603ef91">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c67a9e1d-9377-48da-ab76-b1ecf44877dc">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c18fb56b-a2a8-4d99-9f07-1fe5ac7b6ea9">EV <link linkend="DCM_121150" xrefstyle="select: nopage">(121150, DCM, "Device Code")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5d7a1537-edf1-4d20-9c1a-aabbbbac4c86">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ab56d6d4-5bcc-41fb-8be9-d194b62d24b1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_729bdd5e-cdda-4e92-98cd-cdc71abc3cdc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2de7a86c-24a2-4f49-b904-f90393d9afae">Vendor or local bar coded values</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e177b0a-aea7-48f4-88dc-f2a3a5d74c17">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85d8e526-1e5b-4245-8805-0eb0b233138c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_44cca77d-69e8-4d44-a4e5-21b4ea211b84">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a13d2b36-727d-48fa-8363-b0110d39588a">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4a95c93-1678-445e-b5a0-47b4de39f871">EV <link linkend="DCM_121145" xrefstyle="select: nopage">(121145, DCM, "Description of Material")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_77eb7414-7258-4d77-aabd-8535bfd8c740">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cfeb18c3-9666-4491-a0cf-c8ca9621510b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f05a18d-8870-422e-9c87-01b284717b15"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fbe97f06-f6a0-4757-a5e5-b1513ec1fc32"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72f7b6c7-ba51-4af0-a197-34e29a460c39">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc5cef87-56f2-4f93-adea-57cc8890a8af">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0632d7e-3172-4363-965c-87e4ec997b0e">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da32a926-14b1-49a4-832c-a06bba3b513b">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e71192bd-a551-4787-9be5-41eb3639dc1b">D<xref linkend="sect_CID_3423" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc993caa-412a-47e4-960a-6a21734a503f">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3a2e0fda-7966-4651-a0b1-7600dd3f81dd">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2699c3a4-6288-4809-b612-2c8e88ea1786"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98819751-54d8-4731-95a9-6605f6f43446"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4dba8b2-b93e-4e0f-8557-5dc6718eb092">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4423a85-270a-4447-aee6-e77a5f812351">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46d2bd3a-8fac-4534-b0ff-cdc70fda53bf">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c875456e-7d00-49a1-864c-dfc6f9dc9925">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2cd6934-e729-4234-93e4-b7a8d06bfded">EV <link xl:href="http://snomed.info/id/363704007" xl:show="new">(363704007, SCT, "Procedure site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_759a8d18-722b-4fdb-9050-3ed02019cec1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7bb9c455-79f0-4be4-b386-d150c6db9f0a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_834ca8c8-887c-4ec2-a829-c37582326097"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c405a5f3-bccb-457e-b398-c16ab95f9c0e">B<xref linkend="sect_CID_3630" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8660a8d-727b-4d7d-a95b-6524d7170660">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c7d75dc-c147-4ebd-9c04-0b0efe356437">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67622736-cc8b-4611-a315-789e0f03dd20">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_71ab6e03-78d7-4072-a35d-d291d2033fe8">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f381f27f-eb98-49b7-8910-6c5e207e7668">EV <link xl:href="http://snomed.info/id/363703001" xl:show="new">(363703001, SCT, "Has Intent")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6d08d14a-64ed-4d30-8a56-d238fc65289a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_658e2951-bc9e-4704-9c12-4f61aa6df857">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_900fb41a-987a-4877-aded-3f84924cd46b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_01464bd6-68b9-483d-9027-ad0d2ce05b65">DT <link linkend="DCM_121155" xrefstyle="select: nopage">(121155, DCM, "Deployment")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_278b4b8a-53ca-43e0-a3c2-b82e001a24c1">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f849fca6-2438-486b-b7c7-e519e2c50550">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9371b86a-6089-4c84-8370-f5a019650b11"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fcb094a2-ea38-4630-b06e-dddb14e2753c">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_261faf02-60c5-4403-b9e0-11c193c2cbb1">D<xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4b8690b2-d8c6-481f-ad60-0fcf27fce484">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6201ba0c-d044-41b4-b062-05fca2dc1522">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d3bb252-e7a6-43f6-801e-983174d0a2e1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5177612e-4596-4854-af3e-6fcaa8464b17"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3108" status="3" xml:id="sect_TID_3108">
                <title>Intervention</title>
                <para xml:id="para_f945b6f1-8c02-40d8-8e29-f13067371c0f">The Intervention Template allows recording of interventions, including atherectomy, angioplasty, stent placement, brachytherapy, etc. The record may include reference to an image that documents the intervention.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_e9454512-a8ec-4730-9924-2263826fc9a4">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f525ced9-4d25-4301-8361-874a5c3872b9">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_72521861-18ac-4faa-9b72-a5208728c64c">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3108" rules="all" xml:id="table_TID_3108">
                    <caption>Intervention</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cff439cb-36d3-4e0d-ad9d-d2adedae57cc"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f04d6367-f3b9-4902-b607-46e92c070d0f">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0c60359e-e969-4138-becc-3c84dc30f3ba">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ba0793d1-a0ab-459f-a4be-f5cb54f3b742">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_77aac478-1950-42ab-9059-9615f510efe0">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5bdfbff4-a251-43a4-834f-d0f8ca5f81c4">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_53ae8c09-80a6-4a9e-ade1-083d738e6b8f">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dd5c1845-57c2-41b0-a363-ede02eaaf395">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4fcdcfcb-50b7-47d7-be6c-3aec3815d316">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e69b0c03-5b75-44c8-8124-f590a59ed567">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5fddeee-e838-46c8-b7ca-b5052bd122ef"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a44b1bc3-edf0-4ef7-a926-9549ff9ad982"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b206d1c0-3861-4a1b-999b-bb43cb13dfd8">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bfde8d80-9506-40e3-a709-7aada0728889">EV <link linkend="DCM_122090" xrefstyle="select: nopage">(122090, DCM, "Intervention Action")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8053cd16-950f-454a-b5cc-25725b015ec4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cecba0a2-4a52-4011-b830-15d838d02313">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ef99e52-795d-4a50-bd08-caac28421be2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa8e89fe-859d-41ca-bb12-f1f6c316d91f">D<xref linkend="sect_CID_3412" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55acea3f-8c32-424f-96d3-8d3f7eb9df96">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6de8e0ce-4390-4e69-bcef-a079a5bfcdb5">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_33797712-33c5-423b-85fe-787d588d9b7d">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9389c27-4016-4f39-85ab-816e55fae2b3">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_78e5db41-a42e-4495-950b-3eea6281398d">EV <link xl:href="http://snomed.info/id/363704007" xl:show="new">(363704007, SCT, "Procedure site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_186122ae-8395-473e-b893-03397a1aec35">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_86dd2cfa-4313-4607-8cc5-156a6dc97ada">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c532ce89-861e-496c-843c-1b813605c5ab"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d64d019b-6b5d-4dc8-b84d-9a686569f40b">D<xref linkend="sect_CID_3604" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a457e9e0-78c5-48d4-a457-320e1d66b29a">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_691f4c3d-018c-4916-b585-dc64fb6783f7">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3988570-1b59-4d81-9035-68fcef7588a0">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c856599-b6fe-4f8a-9c2f-f38c954630c7">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4fb984eb-a310-4f54-be18-a05a34d0acba">EV <link xl:href="http://snomed.info/id/106233006" xl:show="new">(106233006, SCT, "Topographical modifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_97aa9db5-3b2a-40ca-b36f-8054a4b30f30">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e06e56b2-0293-4277-987d-24bd109fb2a0">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a245c347-8d49-45a6-a0e6-70f6d114ef47"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57d81eb8-d581-446c-a569-8299399422cd">D<xref linkend="sect_CID_3019" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5516eb7-ec37-4ed7-99ac-b603d84de77d">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee07bc82-7df6-4e34-bc3b-d79d70a3c380">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f76be03-cc49-4066-b7b8-653442189c9b">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e133a866-99c2-4630-9bfa-0a2aa2a66162">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af29d217-09db-4daa-860d-571626ca6663">EV <link linkend="DCM_121154" xrefstyle="select: nopage">(121154, DCM, "Intervention attempt identifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e0a0f733-e92d-46bb-a07d-84b087d9f734">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1bacc0bd-f755-4ab2-8786-aabbd2fae68c">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d45aef4-9d62-4ebb-a884-adc328b826a1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b42b871d-5443-41c5-9c5f-348e0223be8a">Up to 3 numeric characters</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_53b86f07-4d19-4208-9add-bb4ee18bb1a1">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c2def46-434f-4f6a-a940-d08ee411ef2e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b30172ed-9a22-4c8d-9dde-3cca1a0898b8">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_040c6c5d-bd68-4802-81cc-7073d792ef94">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_457c6c5c-eb30-49b4-87e9-1354e6a28632">EV <link xl:href="http://snomed.info/id/116682006" xl:show="new">(116682006, SCT, "Uses Equipment")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7e2b2ace-1116-423b-97c9-7f034b94f19e">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_484ea821-cee0-4960-b4d8-787f7673b267">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_810891a1-b596-415f-92c1-4ce27b0045a8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22c9b19e-1637-43f8-8641-f0c06241c040">B<xref linkend="sect_CID_3411" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5765d64e-80c2-4ca4-8aba-89b27afa424f">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_921484a3-6f8b-4278-8ee7-177cf7d9484c">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd4fd29f-2039-419b-8b3e-324b1f4aa802">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f528b69f-adb6-47ec-baed-657df3377874">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e31d645-4836-4875-a759-8fdb4ff1bf42">EV <link linkend="DCM_122111" xrefstyle="select: nopage">(122111, DCM, "Primary Intervention Device")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2813e8e8-3433-40e9-9a3d-107f122beaf4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4ee8ffed-0198-4eb9-b5a3-a54e490f6c26">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6582c746-99eb-4cf2-a84f-0f02fb61a966">IF Device is Primary for this Lesion</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38d69897-0744-4eee-ab06-7118ceee500e">D<xref linkend="sect_CID_230" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af98bb6d-1161-4cb2-ade5-b2e30f322031">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f47493e-7290-41f2-b87b-bcabc16f3e32">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_479c88a1-ec0e-4342-92cc-86095a1be9db">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c19b2f14-a7d2-4075-9b8e-e062926631bb">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c6970600-ca92-4ac5-b456-5aa47df9b3e7">D<xref linkend="sect_CID_3425" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eb2d5208-19d1-4e92-ba4a-a8a12dfec7e5">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ebec2c00-00ca-418b-b7c3-2ac303fe9c6c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eee96868-9de3-4cea-95c3-54bf345ab4fe"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a36db3c8-13cd-4008-b8b6-e2730a179c6e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e56dd2e9-214e-4788-8d5a-8ccee4e2009e">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e1c1da0f-6b1b-4570-9bd8-0450e68f7b05">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24c30bf1-16b1-4919-9b81-2b37569156da">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_541a5c83-cdb4-4214-9da1-ff4deff74c47">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4cd93c5-05b7-4b10-8b2a-99c6601e152e">B<xref linkend="sect_CID_7003" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0c5a0140-c8cc-4386-93a2-6f539601111c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_adb783d6-f65a-476e-b2d9-2e53d44ae0db">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05924478-2d34-4f95-81b9-22ea93ebb24e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c8e4747-32a1-4251-8c9f-fcdc5356126c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d4217b0-e2bf-487d-9b48-1caaf8687f2c">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5285d4c5-c1c9-42b2-9978-343245471de7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b6b3b6f-8eae-41e3-9841-ff7012183c6b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_19173c93-6b92-4f7d-b531-5cc5daad96e8">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0939b8d5-6bda-4880-9dad-ff062cb857f3">D<xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d19f4984-6e60-4821-882d-53d61a1a9c96">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_07cd7f9f-6bb6-42fe-9834-950e8ad92d26">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_085e2a09-d2ed-49b1-a433-c2082d995bfc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5cfe8d4-9d41-412a-b456-61e296f842e7"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_67b75881-3453-4398-879e-e5c3bae2091b">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d21e9cc8-6bdc-44ce-a1e2-396dc186f865">Row 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9186a9d-6399-4720-8ebc-685f27319ec0">Intervention attempt Identifier is specified as a numeric text string, and shall be treated as the ordinal of the recorded attempted intervention within this procedure (i.e., "1" for the first attempted intervention, "2" for the second, etc.).</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3109" status="3" xml:id="sect_TID_3109">
                <title>Measurements</title>
                <para xml:id="para_128aff87-7ca2-4f86-9714-595184742190">The Measurements Template allows recording of significant measurements, such as vital signs, laboratory results, hemodynamic measurements, or quantitative analysis measurements. These measurements are often quoted from another source, which would be documented in the included <xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_bd2c70ba-b3ce-4ee4-bab1-ed31cb97b487">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f524d1ee-575e-49bd-96cb-22fe07a1478a">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_cca78073-c0da-4bab-91e4-4280577de1ae">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3109" rules="all" xml:id="table_TID_3109">
                    <caption>Measurements</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dd284b61-32c9-4d90-b5e5-ca5e0bfa075b"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3dbe9c9c-bd1b-40d5-adea-1ba78d1528d1">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dcc8c12b-0ff0-4858-9d65-a1e813557792">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_877096c4-53c7-4b5f-a4f8-fc790dad0ca3">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0e58c1c6-f5c1-4be1-8668-2878072d04bb">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5cdf0923-4988-4555-8db0-aebf66ea523d">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f0c7a13f-5c77-4057-a74b-2913b9bb0e58">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69de3bc4-4df3-420f-a428-404efca8a8b1">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_72ab0a05-60d4-4d7e-bd7d-88bd63a1a130">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_32547e7d-760f-47c7-a3b6-09046552a3f4">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_243351ab-adbd-4e63-93cb-36681f139b9c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d40e87e-bf67-4c0a-a9a1-c438a01b6895"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_257a9737-f7a2-4d50-9d1e-982aa7f5573d">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee1b421d-67a4-43c2-8efd-29effb54d430"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_775a0751-0aad-4e09-ae47-f4fd2ec3949c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c24fbd56-8bb4-46e7-98be-4728057666b3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b5e3560-790c-44f1-ae6c-979064c466a1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eef50881-bcde-4596-882e-264492a1cec4"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6181b88f-b3bf-4116-ac81-975616970c8c">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_607838bb-f429-418a-b988-e76a4de4ff73">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a65f898-d66e-4d3b-af7a-cf0189e8c5ff"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ae4563e-9d1e-4aac-bd45-3b49b3a9a1e8">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09b74b77-93b5-46c3-a906-ffcb3eb3b3a6">D<xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ae96af0e-f104-4e62-b2c6-55ce6f21445e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_16c6de58-db08-4e2c-8aca-b33680ed207d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c62386d4-6065-48ec-81bc-1290a756d0b5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_196bba33-cc00-42fa-bc0c-2ae5190d666c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cbcb9ab0-901b-4963-ad72-f9dc2359540f">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6805d77e-3bd7-4ad3-a018-71cabbc752e1">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62bffe50-f853-43e8-a33f-cc28ea4b9a50">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_438fcb62-ad23-42fd-b068-f6836d3d2dbc">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29cbfcb1-6e92-4e73-b67e-eb41d34f2314">D<xref linkend="sect_TID_310" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e8b7b39f-f233-47ed-9e7d-a0bbac7ffec5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_27cf45bf-e51f-42aa-99a6-0f29d03fae70">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3901ce30-bcba-413e-8212-7eeb76ccd458"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_520aeff0-999c-40ca-91a8-9afdbb28628e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6952349a-ddf2-4a5a-b9ed-6d7d89c2908b">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_204e496a-5f48-4c65-a604-5a195f1b1d29"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dcbcc365-ee36-4044-9079-4e16f91241ec"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9cc8f9f4-3729-4522-8903-5c29190f6023">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b11938d-3130-4e51-94aa-6dd6d9d8056c"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8dc30aae-9992-47e6-b215-b7bd0eda1bc9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f8d6fb98-93e0-4533-a023-e98196e89ab6">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4166b799-3075-4d92-83ee-d27af0e15a3e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9aa65fbf-c893-472e-a0d4-3a6b62bb1f5b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_afcc0a91-ba2a-412e-90a0-fdf0a71f4113">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d7d4617-ba43-4511-a8d0-b3a221499a06">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6162acb7-899e-414a-98f3-c68cacf5e297"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_53209edc-9dc6-4645-a932-6b4ba29d78ad">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6da18e3a-16cc-481d-ae41-05fade694030">D<xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f9bd9501-6219-474f-8af3-abafeda499e5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a861d65e-a227-41c3-86e8-bc129e0e11c3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61e676e6-62cd-4d14-aa5d-0e685bf0a454"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c60ee583-b3e2-4956-9bea-deaee9312fb2"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3110" status="3" xml:id="sect_TID_3110">
                <title>Impressions or Findings</title>
                <para xml:id="para_388e4e51-f2ec-444f-aec9-003ac674a3df">The Impressions or Findings Template allows the recording of unconfirmed (provisional) impressions or findings noted during the procedure. It is not intended to convey the Cath Lab Clinical Report (the formal report from the performing physician), although it may be used (like any Procedure Log entry) for the subsequent construction of the Cath Lab Clinical Report.</para>
                <para xml:id="para_f8660317-996d-475e-9e16-b1c1fbb062d2">A finding that is supported by a specific image frame may reference that image in the INFERRED FROM / IMAGE row of the included <xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/> Template.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_7edc1ab8-3fed-4cb8-b850-002a5030a24b">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_27209d93-8f4a-47da-8805-00441adee203">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_89fa544e-8131-4cd0-bed4-a0b32abc816e">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3110" rules="all" xml:id="table_TID_3110">
                    <caption>Impressions or Findings</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf38896c-ffb2-41c9-9228-86077bdad456"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5b84be62-0133-43c9-9332-7ae30493080a">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_630f1436-b8ca-43e4-84c2-f12f9476a0b4">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_903b54b3-f785-4658-b6a3-226ed3f738f5">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8795b061-350c-4336-a523-c191993dc629">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_719b4314-015e-4b83-88d0-37cdb60b0e24">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3851d8f4-9bec-48d2-be35-c0741a2ed870">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8537bb1a-11a2-4334-ae19-80eb2859cd85">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_641b34ee-24e0-446e-8404-fdf8987f4800">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82930d7a-0934-4cf0-9379-3a2b92e77ca8">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9dd4484b-8ae2-4fc5-b609-8ab5a6951503"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aef86c9a-fec0-4568-a70e-d9740442a006"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0221e458-1c80-4c26-8b53-61a9b955a63b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a993fbaf-0308-466d-8f1d-edcaf9d0f3b7">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3a7c429d-dc4f-4a62-a54f-8e72e1053370">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_63a61e9c-abdc-43ac-98ed-30b4b7081756">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c3474c1-dbcf-47d7-b293-eb033a31c363"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_489cdffc-4728-40f0-825d-37fd284f9197">B<xref linkend="sect_CID_3728" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6dfab591-b249-40aa-babf-3bb5b2498758">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d12d2536-eadf-4f66-acf4-6fb5f8de4c4a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9bf4726b-4b8f-435e-a8ab-0101ae40f13a">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b3cea12-8826-4f61-a036-6cf15071215a">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9a2f071-51cb-48d9-bfef-1e7d2951721d">EV <link xl:href="http://snomed.info/id/246112005" xl:show="new">(246112005, SCT, "Severity")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d80d7ff0-fef1-4a52-9bd4-eb54e837b343">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a3cb7093-c6a0-46de-ac7d-b0baf3d19eea">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c87b88f-624f-4926-8d91-7a92209c9224"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46f4abb0-b854-4c20-b434-cff643a1110f">D<xref linkend="sect_CID_3716" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e8e83c48-d553-4e9a-b035-97fb17b0050a">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b6f1191-b9d3-437f-804b-c80ee3abf76c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4a66b0f-9c05-4836-ac7b-a487b97d5cba">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_795c39ce-615e-4c41-ac24-8c651f75e568">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1903e7fe-c2d8-4ad3-b633-b22d9a088490">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dd8bf1e8-d297-4e84-9012-3da08b6e2dc5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_02e2d9b2-02b9-485a-a2cf-1b8d956d8f66">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03ada99b-3208-445a-952e-4db41a4cdcd9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_885bb24e-8f19-49de-9788-0b0ca05e4eae"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b962314-c5e4-46c2-80b5-1dd0064ac18e">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2bb7e087-0a8c-43c4-8d02-1d0d5b3920d0">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_071fd5e1-89b6-4064-ae2c-8a751d07b3e2">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2c6763c-aeee-49da-9f46-e426b0666d00">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_581a9814-172f-4128-85c6-56409691125f">EV <link xl:href="http://snomed.info/id/106233006" xl:show="new">(106233006, SCT, "Topographical modifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c1a6f48d-2126-4155-83aa-10e7f27f95db">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8e181891-537f-4785-abb3-174a7cd5687c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_064f08d0-fc00-47cc-ae12-cc4687c4d66b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_898e3243-31f8-463b-9262-4b6baef1a558">D<xref linkend="sect_CID_3019" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_680bb616-3137-40f7-ac8a-4ef6d0e3cf3d">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba5d1323-5e09-4271-a8af-5a7179d405af">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_15157ec6-ba28-4aa8-a544-777582a8b305"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31f9a501-c293-486e-8001-8883da226241">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1807769-9cf4-40af-a88a-9f14c74d3fd0">D<xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9eba0588-77f3-4b86-96c2-8cdb8fa63eff">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_52bbbb78-0ada-4ce3-9296-fde6a267e224">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_56af6b87-093d-49b0-ac7a-de9f7fb86763"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7a6834a-6fe2-493f-aadb-70d2d97ede47"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b93f616-fbbe-4d53-b224-bd92ddd7d445">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dbcc8495-5d61-4441-b82a-806d90f90f0a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b6ea1f0-460d-4ce3-af88-94aedde723f2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1ba44a8-2551-4dec-b235-07f0e4d36068">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f43af1d-1d62-4409-81c4-1c4d99dacb8f">B<xref linkend="sect_CID_3419" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_adbead6f-e892-457b-bb13-195dc8ab3c1c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b0ee6e4b-2f5c-41e2-82c0-ee79147e0eca">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42d7b90f-c942-4134-804f-79797808a06e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22c16610-6703-4c3e-81c9-cf65efeff933"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d27db21-3158-49d7-8040-1a61f099f7ad">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31e34f36-d24f-4799-96e2-72f5b05778b2">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_194c7f63-f2ec-41bd-85e2-ab2c8aca5d95"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b35ba92b-9aef-4884-a8e8-fae460397705">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d50a428e-1bce-47d6-b692-d04d23a321b5">D<xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_567912c1-5794-4b39-954d-b5a462f8125a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4f9dafb1-3ab6-4f97-8377-9a0cbe1bf27d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ad7f345-bb3d-494b-b592-5a217cf63233"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c39af7d-d5c3-4095-8083-f76877774cef"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_550fb67f-b57e-4e52-aaed-f986bb2016b1">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00a689d5-e96d-4ad8-8287-332772ba8709">Row 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0605b3d6-3a5d-4bb9-834f-e7c92a60c296">Finding Site has no Baseline Context ID specified. Typically terms would be drawn from coronary segments, other arterial segments, myocardial segments, etc.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3111" status="3" xml:id="sect_TID_3111">
                <title>Percutaneous Entry</title>
                <para xml:id="para_4d524ab3-fbf4-44c9-ae1d-cc2747002ce8">The Percutaneous Entry Template allows recording of the opening or closing of invasive access ports.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_49aed2ac-88ea-46fa-9154-c96e6a3aff51">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_9d9b4181-7986-459d-9ab2-ea04783827f6">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_d2444292-e2eb-433b-8a63-87f69fd81228">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3111" rules="all" xml:id="table_TID_3111">
                    <caption>Percutaneous Entry</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a17d979c-8642-4c58-8fc3-45e5d20d3e83"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_56ebe2a5-b710-4ed4-bf43-57be090afcfc">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1d928896-09ec-4b74-9073-268b2600ef9f">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a13296df-8b98-4828-aedf-249b7b3fad54">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ccb942fb-35f0-40fd-b3b1-05e50e6bef58">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2b12dfcf-1418-4400-a274-35343275c4a2">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_38bf366f-3549-4c5c-ae2f-b1b01ebe43d2">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3998f01f-9c57-4dc7-94f8-73302ea910e9">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b69658f-3cdb-436d-b473-f9b11ae78047">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_083b6e36-36a2-4a2b-9fef-2f6cff3ebebc">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a04d87f9-b8c6-46bf-945c-4dbc7612cf1c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c590e011-3404-45f9-9fe1-08ce6798d8eb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e1bec6f1-76fc-459d-8c65-6a065aa74d2d">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f5f7ced-d6cf-4da7-8f77-8857c09c7441">EV <link linkend="DCM_121156" xrefstyle="select: nopage">(121156, DCM, "Percutaneous Entry Action")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dba9cd1f-86f8-4bf7-837d-4f8b8febdf38">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_99730ecb-3de9-4e1a-9327-87fe2950b03d">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48f9f080-8347-4a76-bdd7-2db2e2394868"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69e56f8f-95b3-4dd1-8659-cc7f7f79a6c3">D<xref linkend="sect_CID_3403" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_40f6ce3f-88b0-44d6-905e-bc9b4e3aacbc">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_998be3a0-d344-4453-93ac-ae54641bf503">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_befb4d43-6b64-40a4-9fe0-7626b5527165">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_abace8c7-e190-4e14-b691-b3a81dca5999">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7bac400-ae16-4c99-a1df-0c09d6a22b59">EV <link xl:href="http://snomed.info/id/272741003" xl:show="new">(272741003, SCT, "Laterality")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c6dfacb1-43a7-49fb-8bac-935eebc11d79">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c45d5730-d088-46fa-bb19-d358f5378225">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_23609263-d512-401f-94c2-e39e55126b74"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf799b13-6598-4c5b-bdb8-6b3425cb1d77">D<xref linkend="sect_CID_244" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_49690019-f816-4c22-9065-76bd59ea2552">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0404bf57-ec5c-4a23-8f5e-aaa9314eebde">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10207ab8-3ac5-47bd-8fe4-fb67b43ad90b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b8f07100-4b73-4dcd-8509-1fe78c74de7f">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a9e5753-f5d4-4553-9499-18fe14b907d7">D<xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_74769067-66a0-46ae-b6a6-d10ef378ed55">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1d4c34a5-bbc0-423e-95b3-6a58b79337a8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_28b0a1c8-ee87-4d37-8100-90dd29747d5f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d6797893-d313-4757-8403-788c498be8d3"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3112" status="3" xml:id="sect_TID_3112">
                <title>Specimen Obtained</title>
                <para xml:id="para_e9455813-d6ee-4767-8c1d-6e5fb0d0c0cf">The Specimen Obtained Template allows recording of obtaining a specimen, and the identifiers for that specimen. This is particularly designed for blood samples that will be analyzed for blood oxygen-related measurements. The analysis of the sample may be recorded in one or more log entries using <xref linkend="sect_TID_3109" xrefstyle="select: labelnumber quotedtitle nopage"/>, or in a separate Structured Report SOP Instance referenced by a log entry using <xref linkend="sect_TID_3103" xrefstyle="select: labelnumber quotedtitle nopage"/>.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f853f6f6-9ac4-47d9-9835-0d99e8e242ff">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_0844aa57-bcdb-442a-81fe-3cd21c0ecae7">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_655747df-74b6-4c50-b027-9bb04471db78">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3112" rules="all" xml:id="table_TID_3112">
                    <caption>Specimen Obtained</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e1ca6507-eb08-4b7b-bb58-6c8a85d73fc6"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ac4c087-6b20-45e0-867f-09556792ef65">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f4b92179-83ff-4ef7-b4e4-48f5a0c81eb5">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f1d9056c-39cf-48b5-b100-6bc572ec42fc">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eb6e8b5a-5261-4c3f-b25b-e8c1cfa93456">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_37193918-afcc-4888-aac1-6e85d8bc56cc">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e3bcab75-4de5-48d6-b0bd-90b6e17d81c9">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_74ed2cc0-3dbe-4a7a-baa2-ecabdd3f2673">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aa36b194-a6b2-43d0-b5a3-5c20a764085e">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84f8cf45-deb2-47bc-a5a8-d6357838c73d">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4971934d-9697-4bf3-8e0f-95dea9fbce9b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_edefc036-d863-4b7c-a286-8ec9c26d6df9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b87d2436-660e-4710-b111-3878268697a1">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c00e06af-64e0-4404-a51b-710480ec22e1">EV <link linkend="DCM_121123" xrefstyle="select: nopage">(121123, DCM, "Patient Status or Event")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_678981c1-9dec-4dee-911e-3c7bb4b76bb7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_44f292ce-00d9-455c-8d62-fd0c89fae193">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5abd380-6627-48c3-aea3-1973cb15aa83"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_90369e75-5be0-48e6-bfbb-83674a0d8672">D<xref linkend="sect_CID_3515" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_405b08b8-03f4-4949-b726-894b4dde1ae5">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_461e7cd1-51c6-430c-8762-b1139919eb3b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87e2c586-ec53-4256-87e4-9ee70725bc9c">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2634ac7-e75f-48e9-abc8-7b5ec8cd1982">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6fb9c1c-38b5-4d0f-9075-1fc80dc34f6c">EV <link xl:href="http://snomed.info/id/371439000" xl:show="new">(371439000, SCT, "Specimen Type")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eaa37ba4-3905-4249-8386-3621ab26ecdf">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ab740099-7506-4327-9e02-f9c914958b5a">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a1fe7439-b146-4af2-a441-20b4572fbc3e">IFF specimen is blood sample</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_449ba157-4312-4ab0-a476-99ca6acf73ae">D<xref linkend="sect_CID_3520" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99471a02-18ca-4256-a093-b1df37a36146">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a976fca3-cd65-4bb0-954e-841fb9fcb881">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe444e27-00a4-4e93-add4-fd01c00ff5f9">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_922a4593-8cf8-4214-8978-79835632ff9e">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_148642a8-6c9c-4835-b671-5f8eedd4aeae">EV <link xl:href="http://snomed.info/id/363704007" xl:show="new">(363704007, SCT, "Procedure site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_03549a2a-5ae8-4fa5-bc55-0801b4a9dbaa">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ce6ec8fa-b49d-4cac-a623-706bd22afe9f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1181172-904d-40be-97c9-706d0d03a5bd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee0be856-cabf-43d5-b284-c2162fa0f9ee">B<xref linkend="sect_CID_3630" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f72d976d-d1ce-401d-b31b-20e0b2e4bb46">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e630ab95-297f-4138-bd01-abb35876940f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f22a06b7-ab8d-498c-9d88-3c3525710f7b">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a798462-d2d2-4831-9b31-01d355b0dbb3">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_120a945b-ae2b-41d0-854a-36d6f4a164b6">D<xref linkend="sect_TID_1009" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_04d12cf8-e36f-469e-bde4-c53d479de6a8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bcc7f11a-520f-4404-aa55-db46a21c0015">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a53befe1-8599-4428-812d-e865cb893bf2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb8b1bba-c82c-452c-9dd9-01bf1a128908"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3113" status="3" xml:id="sect_TID_3113">
                <title>Patient Support</title>
                <para xml:id="para_b4615eb5-3016-44eb-9961-caca0fbdbce9">The Patient Support Template allows recording of the use of various support technologies, including oxygen, ventilation, pacing, etc.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_a3a8ef0b-e2de-48a7-9640-d05678d0e9cd">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_c7fa5a58-3609-42a5-82e3-aa8fea399372">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_3ac1c853-7c2c-41f4-9f1b-41cda5b6bc07">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3113" rules="all" xml:id="table_TID_3113">
                    <caption>Patient Support</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_20a006e6-cff6-45ab-b38b-f818cfe4d7cd"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_62daa529-8e48-4ddd-9342-833cdfa8f500">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9b5bb4c8-8088-4aff-bb9f-848785d844ff">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b413ffc-01d3-4dcb-829f-ff31f4ebd541">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_50fedb2d-c6f0-44ef-8888-3137d326f2f2">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c6ff5f89-2876-407e-8813-24b2a2d8c591">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f5cf1f3-8f25-4304-94fe-49b8181ebb39">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_10d6a31a-cbf9-40db-882c-a450cfa92466">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7f3089f1-2d12-4d48-bd56-a1d2606d89f1">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_edcc5dbc-194b-48a2-b1eb-aa3fda218f20">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_abcf911c-be0e-42d0-ab92-37a02d303307"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06facdce-7869-44c7-abbf-8ff3a1941c8f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_15aa37b2-58ef-4023-8a6b-f0883fe64647">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7c94c9a-4d7f-449e-adb1-dbd00ee91bc0">D<xref linkend="sect_CID_3530" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_25a491de-7bc3-4ee1-a17b-82a038336210">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_59d6f1c8-099f-4a14-8a7a-44cc342d22cb">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a13daa6-8a42-4e04-968b-5717b6a2cb04"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1a227c1-5569-4a34-8a63-34f32ae77524">D<xref linkend="sect_CID_3531" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ebaa469b-6012-47d2-a615-98fb20a514b8">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72dbcacc-14d7-4ac1-a80f-3a2cd05755f3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8cc48102-35a9-42e2-8f22-5f5075407a94">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_959810c4-e2a4-45e6-87f3-987f86991c95">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92096c4e-cade-4fdc-bc92-450e4086de0c">EV <link linkend="DCM_121160" xrefstyle="select: nopage">(121160, DCM, "Oxygen Administration Rate")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c8015179-c4fd-45de-a016-c64658cdc382">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8df4341b-2891-48d8-b647-0296a1c263a3">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_77c473a6-feab-440d-b5d5-2aa9d491796c">IFF Row 1 Concept is <link linkend="DCM_121161" xrefstyle="select: nopage">(121161, DCM, "Begin Oxygen Administration")</link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a8bb754-e6bd-4ff2-be93-2d9c38c5fc50">UNITS = DT (l/min, UCUM, "l/min")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_766eac3a-89aa-4fb5-8a42-79dab93b201d">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_76271239-d9aa-4864-b2d2-d53f3c8c5206">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58988ef9-ccec-4735-aa8c-cc7dde5b1f31"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3cd6e3dd-2c77-4431-ae01-6a61d15a64ef">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb0e3867-4cbd-4053-80cf-c387218ef29e">D<xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_857406d3-4e1a-4d76-a1d9-be21355e33ef">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6949460f-b29f-4821-b06e-0c2f07155ff6">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85d63d10-f228-4787-b938-72ddf6962dfe"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7df79a4c-d0f3-4d74-b7f6-75e21a387def"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48efb348-afe7-42fe-bb7c-3987a7d0150d">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ef55374-885e-4d0f-ba84-62c2bf067682"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b9708bea-478e-421f-9370-89d1c9a2359b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc39b03d-2520-4de0-9bc3-e0734dd97cf8">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9323734b-016a-4752-8467-85599b75a7e6">D<xref linkend="sect_CID_3550" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0c4ab3be-c8f0-4f7d-b692-f1ba3460b9a6">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a87f123f-4035-4ff4-ba4d-24a92c5f7f8c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ccce2026-9ca6-41d8-97dd-3484ecfa4ed3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67806557-cce4-454e-95ee-dd7b40c3b912">D<xref linkend="sect_CID_3553" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4dea3c9-2335-4662-bd2b-242afc1e7f80">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3183cbfc-6399-48f0-9569-d063687a66b1">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e71cb9f-a312-41c7-b801-c14e86cdb5dc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8441d673-106a-4411-952d-4e539c0f620c">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_316069ea-3842-4e17-8408-fa3c8526f547">D<xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0dfb93d3-ee4d-49e3-bc01-ed6229d5d863">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ffbb82ed-a9ad-4ba3-b6c9-aa0e0a83bb14">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_324b9d9b-b2c5-4d39-b20c-1d6d29971f92"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7347e92e-a57e-43d3-b68b-5e356a359a8e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0465ed79-b2ea-49c1-b2c0-4f770d3d3c9f">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_90f18117-ee48-4725-8c2b-f30014e3af18"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c620ae37-fa0d-4d34-91a7-3da0489404f9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d76afce-3c49-42a7-aa32-8b9b916408b7">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5fda9a21-bb7b-46f2-bbcd-c767b997935a">D<xref linkend="sect_CID_3551" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_10d06b3b-7713-4778-a0bc-49bfbbf81f3d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e82f5806-429b-42f8-9b62-68e25b23d7a5">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eaabc853-fdab-47c5-82e4-3123d78b0792"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16e21e73-8f78-48cd-ac43-1afeebb99a58">D<xref linkend="sect_CID_3554" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8572e2be-7f18-4fd4-b14b-d4d6ef7410d6">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55ec7790-92d5-462c-8a65-41ef62c1d0f8">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_699597ff-781b-4cc2-ab9a-e59dd892a78f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_146cf43c-b2f0-4372-ac4b-da8215a4f616">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d83c3ec9-86ee-488f-bf2e-3b91a2c3ca23">D<xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ffff8a3-7acd-4509-aad4-7d20075334b5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f4b5d198-a8c9-4dbc-8a23-0ada4322e2b4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7fa1ad32-2416-4165-83c4-054124927047"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_60c445ee-1ad7-44b6-a311-9daebdc4ba16"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b826a9e3-2049-4df0-8f23-54e932039732">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63a3c354-77b9-41ba-aac6-75b17f113c51"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7280bcc2-8bde-48d8-9668-78972f87e1fe"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4504cb8-ac91-409b-a63c-4ce5f318e626">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93fe7f2f-be6c-4ea3-8aca-0455bacb6105">D<xref linkend="sect_CID_3552" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_14edf42a-5c3c-48e2-8173-49d5ee985680">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_72c0d7ac-e88f-4a50-9aa0-05fca7dac4bc">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_425696bc-4344-4bdd-9c2f-ffe71652ddb4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9cb7b27b-b746-4a5f-9efe-45ba53a5fa77">D<xref linkend="sect_CID_3555" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d320e0a-0e25-4964-80bd-cd8697a04ced">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f647d3b-efc4-49e5-bf9b-5a706564d818">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98988c1a-a999-4d3b-b5ae-814342a882f1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b436770-03b1-4aaf-bf06-69888dfc5e67">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa188880-6abe-4ba3-a0b6-6719b1691a2c">D<xref linkend="sect_TID_3010" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73bd5008-4ed4-4314-8617-6947878498c0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_341f89fc-0684-4176-8e40-e324aae03658">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac64c908-ece0-41bb-8328-c9cca548fadc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1aeefaf-1df4-48bf-959e-222dbcd9a9dd"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3114" status="3" xml:id="sect_TID_3114">
                <title>Patient Assessment</title>
                <para xml:id="para_51ac2428-2b85-412a-8cd2-51f515e47646">The Patient Assessment Template allows recording of the assessment of the patient's cardiovascular, neurological, and/or respiratory condition. A particular use of this Template is for "vital signs", which are a specific subset of mandatory patient assessment measurements.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f3de0026-cef1-44bb-a360-1034af5508c5">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_3e79020c-efd7-4665-b318-e59b8cb75e8c">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_d53a399f-28f1-4677-833a-d2c278fc0d39">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3114" rules="all" xml:id="table_TID_3114">
                    <caption>Patient Assessment</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0b18fe57-bb9b-4baa-8f78-ecefeb375bc3"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0853969b-a73a-4c1f-9d3b-ecf7825e2e5c">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2ecddfd6-2578-4149-8a9e-ce8b1501ed16">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3c6e0fa6-0fab-401a-a2bf-4bf030826297">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7c5463c2-44fb-4cad-9552-6d3a5c1462ec">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6190426f-47bb-4643-bf7b-060d3eeb9515">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7021fa6e-e580-4dae-9ea9-1f50afb3d3ef">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_70e1a877-43fc-4bb6-8423-2a18ee6f992d">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_46577036-2153-4be8-a569-bfd8d98359c0">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_34f9cff1-b628-4de9-8b89-0837cef29373">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c404cac-4399-4de9-a57d-c8820ef6bf9a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_339b858b-54f3-4099-945e-b06fb00fa355"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97fa5f20-bdde-4dda-9760-1ec071593078">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f58b971c-e659-43ba-906b-bcdea6894cba">EV <link linkend="DCM_121123" xrefstyle="select: nopage">(121123, DCM, "Patient Status or Event")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85965f29-cb4c-451a-bcdb-8db26fe26fe0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bf5f82f2-27be-4f7f-a0f3-a6d0129ecd7f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_710cba7c-3dbd-4b82-8c30-1004192562c7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d615f7eb-febb-4133-8925-d53518b188bc">DT <link linkend="DCM_121165" xrefstyle="select: nopage">(121165, DCM, "Patient Assessment Performed")</link>
                                </para>
                                <para xml:id="para_3c80de76-078c-43e5-9528-d2f443646953">DT <link xl:href="http://snomed.info/id/61746007" xl:show="new">(61746007, SCT, "Observation of Vital Signs")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f741296-8119-407d-8999-1d67723981c8">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0acd051-3639-48cf-9dbf-a4cfcc66981a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_578b2ea1-eafe-40d8-a6e7-ccf15d1ac957">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_745faebb-4891-4459-a982-a6b258aa3364">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ef70383-1023-40fd-a0e5-fcfaa0be3fa8">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3aba362a-f5da-4bbd-92a5-ff669c877f71">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e8fa40f4-b66d-4d5b-9493-d6964d4e2a75">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9db06cd8-55d7-4d9c-b38c-6ac7fbacbff2">IF Row 1 value = <link xl:href="http://snomed.info/id/61746007" xl:show="new">(61746007, SCT, "Observation of Vital Signs")</link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85077922-50ed-4213-bea2-1c7b65305b19">$Measurement = EV <link xl:href="http://snomed.info/id/271649006" xl:show="new">(271649006, SCT, "Systolic blood pressure")</link>
                                </para>
                                <para xml:id="para_e3cc32bf-4221-4a3a-b0fc-b03cdf8e9bad">$Units = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_1553121b-17bd-4ac9-a35f-6fc904de386b">$Method = B<xref linkend="sect_CID_3560" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad0e5f88-a044-45d2-9d9a-7d07d12a1f7b">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43862143-1b63-4fd8-8a32-e86c37e57f45">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93428f6a-703f-4c05-97e2-a5318243e0b6">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98b3b515-15f7-4a70-a9ec-053bfa90f4c5">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9ee59c3-c0e3-42b5-af54-cafed0942c8d">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5ead7813-5548-4534-84c6-c91327224c54">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1e15a0f5-1b6b-427e-b3ae-41629dc6c058">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_19c59ae4-9516-4f88-9b8a-2c250a146857">IF Row 1 value = <link xl:href="http://snomed.info/id/61746007" xl:show="new">(61746007, SCT, "Observation of Vital Signs")</link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_714ced7e-bd39-4ff8-8bf4-c2a37ad126cd">$Measurement = EV <link xl:href="http://snomed.info/id/271650006" xl:show="new">(271650006, SCT, "Diastolic blood pressure")</link>
                                </para>
                                <para xml:id="para_ed5f03c1-bee3-4516-a44a-83ae933d7ed1">$Units = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2f9246e-cd72-4388-859c-a4c8b1f97337">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57b2d113-cc7d-433a-ad59-d7fa718f4c86">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3660469c-796d-4db8-96c9-ab75ed2cddfd">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca602c8e-360c-4b57-be63-a390ab8ca48f">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a7154f1-8f57-4eab-83f3-53c422c98447">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1f4e6bdf-2d41-4979-ba35-948feb103785">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0092e26d-105b-485c-9f7c-5ea9ae8b36de">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e0883ab-2357-40a1-8f01-bf33bbcc97b0">IF Row 1 value = <link xl:href="http://snomed.info/id/61746007" xl:show="new">(61746007, SCT, "Observation of Vital Signs")</link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5bcfb1bc-a897-42c6-9154-b97a664db6f1">$Measurement = EV <link xl:href="http://loinc.org/8867-4/" xl:show="new">(8867-4, LN, "Heart rate")</link>
                                </para>
                                <para xml:id="para_f524a9ea-fb4c-4e92-b228-eb436a4c0b78">$Units = EV ({H.B.}/min, UCUM, "BPM")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3136b536-2a8b-4025-b184-54648db55230">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee3969bd-82a2-4ed2-9f22-4f289238b664">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d732450-025b-4768-9116-4c9825ba1577">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e1e4b45c-9efa-4d88-830a-1d8abb0eb322">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d92fa42d-a95a-4189-9cc0-46de1b1ff0fd">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_698cbf06-c4b6-42c0-ae47-78c14fa9cf07">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fe4c3588-6f6c-46aa-a22b-b819d8e7923e">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_093acb79-793b-4df6-a11a-b90af0a605e1">IF Row 1 value = <link xl:href="http://snomed.info/id/61746007" xl:show="new">(61746007, SCT, "Observation of Vital Signs")</link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a3b9ce7-2f6e-4c0c-8be0-805ab342acce">$Measurement = EV <link xl:href="http://loinc.org/8310-5/" xl:show="new">(8310-5, LN, "Body temperature")</link>
                                </para>
                                <para xml:id="para_81f3bc4e-8f00-47e7-b2fd-a553797b8867">$Units = EV (Cel, UCUM, "C")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42c1e945-50e0-4b9b-9f5e-01dc88ad628f">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d37a55e1-2338-41be-be9d-f5496bdfc366">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d50f6f3-ef2b-4274-97f0-2dab430d8ce8">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65d9ea4e-1d6f-4827-9a08-b5899e00d8d7">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24b0530d-5c42-400d-a0df-e8ab558277a9">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8827281a-199d-4aa6-82e8-18028c251b85">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c44fb1c-5d13-46a3-91d0-edd014944a6d">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24a60051-4956-44b7-86ec-a30639b0f2d0">IF Row 1 value = <link xl:href="http://snomed.info/id/61746007" xl:show="new">(61746007, SCT, "Observation of Vital Signs")</link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_535153ef-b5a6-4440-bb4e-f3865ec259b5">$Measurement = D<xref linkend="sect_CID_3526" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_e5db70a3-3f08-492c-8612-b0b3c98476da">$Units = EV (%, UCUM, "%")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b507c84-e3ff-45a9-92fa-ce689de93d72">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3bdd2bf4-5547-4b58-a2b4-e4c282cab84e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65c33a4b-4050-4231-a956-6e299c9b8766">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b67ec4c9-883f-477e-a00c-924caf43baf8">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63abeb08-b103-4132-b3b2-548aa7f4eb60">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5ea6e6fd-85ac-4920-aa3c-edc19fc985f2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e130d845-7260-4793-b10b-52c39be93fa3">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22b1f0c0-1370-48e0-a17a-9c370c832707">IF Row 1 value = <link xl:href="http://snomed.info/id/61746007" xl:show="new">(61746007, SCT, "Observation of Vital Signs")</link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_726f3aa1-1d48-493e-9086-253574499d8d">$Measurement = EV <link xl:href="http://snomed.info/id/86290005" xl:show="new">(86290005, SCT, "Respiration rate")</link>
                                </para>
                                <para xml:id="para_f89b2dbb-3f16-4e60-bfcf-22ec7aaca61c">$Units = EV (/min, UCUM, "breaths/min")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_49e8021b-1ceb-4278-af71-e3cf3a6a5d0b">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5029c8fa-019c-478d-8763-2a3a9a51053e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_56ad002a-78eb-4dec-b483-9f26c223acc1">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0938d370-9b4b-469d-bc50-09ac8f1bb09d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11c845a9-6a07-4fcc-b994-959f24599bab">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e8ace195-e04d-4a44-b0b8-bc7959720c66">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8cff507d-34b7-4390-b52d-519b1bb4bba2">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e66b17e-ba37-443b-85ca-8425cab6c2a4">IF Row 1 value = <link xl:href="http://snomed.info/id/61746007" xl:show="new">(61746007, SCT, "Observation of Vital Signs")</link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d161259-689f-41e1-b96c-ddd960ccd58c">$Measurement = EV <link linkend="DCM_122195" xrefstyle="select: nopage">(122195, DCM, "Pulse Strength")</link>
                                </para>
                                <para xml:id="para_59b6f66f-a4bd-48a1-be4d-7a5b09de7bc8">$Method = B<xref linkend="sect_CID_3442" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_3ad579b3-b809-46a5-83ab-c6234c55fc09">$TargetSite = B<xref linkend="sect_CID_3440" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_8ed664bc-b508-4cc8-b515-c1424446d49b">$Units = DT ({0:4}, UCUM, "range 0:4")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e0319013-96b7-4180-8064-2da5818f87e6">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a157bd89-1e7d-4a90-85d6-9a4ce8da7f23">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_278752f0-f36e-434a-9de1-16d14012a492">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80c08396-73e4-414a-bc69-bc0517b0d5c9">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f952dbf-4e91-445d-9d19-392c6849aa21">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8e0da1ad-07b0-4d96-91db-4e1f4f46add9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ff679798-e50c-40a6-9b53-5831b8a53a32">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_faedb762-44bf-481b-94b5-34cb9747c9e5">IF Row 1 value = <link xl:href="http://snomed.info/id/61746007" xl:show="new">(61746007, SCT, "Observation of Vital Signs")</link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b793a5c6-80f3-484f-a05c-57075ed08951">$Measurement = EV <link xl:href="http://snomed.info/id/225908003" xl:show="new">(225908003, SCT, "Pain Score")</link>
                                </para>
                                <para xml:id="para_5894b421-4412-4704-aab3-3dfce4e0844e">$Units = DT ({1:10}, UCUM, "range 1:10")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce599bb9-cfe5-469f-a389-75a756233b49">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_76b88da3-2ca3-43f6-b047-2c55a8b5d39e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ba0e4fa-62b5-4b14-b317-ad75f80b22f9">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31211bf5-4cde-49cd-8f7e-e0cb3c185ab2">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ade43a99-c374-4c36-a3cc-b75877216e28">DT <link xl:href="http://loinc.org/8884-9/" xl:show="new">(8884-9, LN, "Cardiac Rhythm")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a4450022-ab93-49e9-8565-e14d07a6a1ad">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d7b9ee39-bdff-441b-a947-13293a0c8d33">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f38d02b9-fa6e-4071-8891-d4a522901836"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62c1a98d-aa25-49c3-b2c3-d395d64a1ad4">B<xref linkend="sect_CID_3415" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58478794-4ea4-4385-b8cd-72ff313e66dd">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cadc7746-8ec3-441f-aff5-2f4ebc5f5049">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ccee3019-4bf7-4b9f-8380-8f9ecc159e23">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_debd898e-c1d0-4c77-b25f-54f337a2d519">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a457e8e-9e8f-4cdc-a6b7-e930489e4f82">DT <link xl:href="http://loinc.org/9304-7/" xl:show="new">(9304-7, LN, "Respiration Rhythm")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5f37ef91-3754-46be-a2a7-f2fb51927d8c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b3871097-8c31-42b4-a9e0-3ffa040e2739">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a488e35b-b188-4a9c-93c8-7d12291728e1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c880b86-4228-4243-acba-f2f83ee4ff88">B<xref linkend="sect_CID_3416" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b3637b5-fa55-4db9-922b-9df0bb4e5785">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_283afc98-a509-456e-9cc5-3a0849308e74">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27f22e19-3708-4826-a481-bdbac20ebec0">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1be78bb1-03ba-4556-b9aa-520f720e955a">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc788881-2174-43c7-9205-edd1e3d0c576">DT <link xl:href="http://snomed.info/id/364062005" xl:show="new">(364062005, SCT, "Respiration Assessment")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bed7285c-8201-4b0e-88a5-2529fafa19b8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d514be01-5a43-491c-bdf3-eccac36f4cc9">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eec8cb8b-b9e1-41ed-ad18-121b3cf730c9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c806fb95-b619-4a93-b034-74482808385e">B<xref linkend="sect_CID_3448" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e2f45f6-cb2d-40d1-b879-c83634d76638">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ee8a189-98c1-4767-993b-c3a3d4bfb35c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4616b70-2fac-4f71-948f-cb057b86bdf0">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa948984-10a1-47e1-8df3-9ef8e0db0404">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_319262a6-10ed-43c1-a686-5b5a2f74a27a">DT <link xl:href="http://snomed.info/id/364528001" xl:show="new">(364528001, SCT, "Skin condition")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a6c34658-dc95-4305-ba08-af33ba250fa0">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_62af9316-94e5-49c5-8d4b-476bf675c0ed">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4034e127-2c10-4b7c-9385-a3e10338b915"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65c1acc7-9a3e-42e2-a0ed-704907f7db16">B<xref linkend="sect_CID_3446" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d7f987b-a52c-4030-9559-9fd814961c79">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_898d868b-2bf2-4a6f-8c0f-b2540ffaa501">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67506199-9d4d-4e7e-9f76-d33f5f468117">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1698c0c1-bfe9-41fc-b3dd-8ad3689fd3ce">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fef5eb09-5780-418d-9fc7-9cafd69298d7">DT <link xl:href="http://snomed.info/id/363871006" xl:show="new">(363871006, SCT, "Patient mental state assessment")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f2b8a9f1-66cb-4303-926e-00a9388b4fa7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fed063a9-965a-4e60-9530-b0cf28d8df45">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bcd38edb-b45a-4e4b-b991-6b1ed7a3988c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c732e532-b42d-44f8-8ccb-d3d86fb9f3b7"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b31437b-d79f-44be-ac32-306cf0988e9a">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ba7de1f-c496-46b8-b405-3ed882c452ee">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab6c1ffe-238e-49fa-b707-71a21b902ff5">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2ab0554-299a-4d20-9c1b-a0e9623697f4">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4938f4a9-570c-4ae3-a5f0-c5453c1b8e18">B<xref linkend="sect_CID_3441" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a3ebe840-8d37-4cb0-8f61-027f43bfa6f7">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_86561c0c-7242-44cd-ac06-b0f64d1c3df4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4aff6ab4-35bb-4005-bebf-7d30044650a9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08292ddb-038e-4246-be0e-9248983859de"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_40244eb9-5090-4276-93c3-0e56eb483856">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05eebfce-a7c0-4c67-8edd-42dddd696395">Row 8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6cccff83-aac2-4306-b972-a8d47652f69c">Pulse Strength allows the assessment of the patient's pulse at multiple locations using the Topographical concept modifier. It may also be used for a single pulse strength measurement from an unspecified location, as is typical of vital signs assessments.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d2fc3d4-5d85-4ffd-b448-a95fae7143bc">Row 16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98978cf9-eff4-4a63-8cb6-2847ff9878f2">Allows free text description of patient assessments that are not expressible by coded entries of Rows 10, 11, 12, 13, 14.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3115" status="3" xml:id="sect_TID_3115">
                <title>ECG ST Assessment</title>
                <para xml:id="para_cb92dbf6-2160-4f34-bc95-8bcf29d9ea9e">The ECG ST Assessment Template allows recording of the assessment of changes in the patient ECG relative to baseline.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_3ccb8cfe-fce2-42fe-9094-293dfe2f0022">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_39d17b57-06b8-4d77-a796-dbf6c0133529">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_167d6ae4-d666-492b-ba81-26c05b35563a">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3115" rules="all" xml:id="table_TID_3115">
                    <caption>ECG ST Assessment</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ff01846b-334d-4bcb-82b4-5df28b972706"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4548ac41-1980-43f2-8a68-6cfbb4ba1463">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f55c30f2-9c14-48b1-9542-c14915eaf966">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_89ee0693-2448-441d-9d8d-b7a689ba3baf">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ded09184-2442-4617-aa5e-21077e8f38b2">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_da37fcca-c8f7-4e93-b1b6-82ecafb73a6a">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_488b1141-d9ae-488c-81f5-028dbf0c4ebd">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_637facd7-25ba-4682-8ebb-40f021ad165f">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8ae6b6af-3d68-46e3-971a-493a2b9cf678">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_336be58d-9377-4d75-944b-cbd4f28ef76f">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5374868e-7949-43f3-b5f0-da4ed4e9df76"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70af4dde-073e-4801-8ddf-c6d45e94d88b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce5d7005-3bad-40fe-b4f9-0751fe80d149">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c9e091c-6e7b-4eb6-a221-ef9472f1db69">EV <link linkend="DCM_121123" xrefstyle="select: nopage">(121123, DCM, "Patient Status or Event")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_057fcb08-8f89-48ec-a88d-06124eeb56b8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f30ea703-4271-4154-94f5-ed4804f1f77c">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d8efdad-3b7e-454c-872b-88aa8be355b0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3067df16-f82a-45a4-ad09-e337abbc3555">DT <link xl:href="http://snomed.info/id/258181008" xl:show="new">(258181008, SCT, "ECG Analysis")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee40fec1-3307-4570-b801-f636cfadfc76">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d65064d-cb4f-43e9-ba12-eeb73a384e70">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5232db24-c087-4ff0-80b5-d96eec75fa5b">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74216879-20b5-411d-8710-06deb6f2dae5">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dec04be0-f304-47f5-a715-711b9b26f719">DT <link linkend="DCM_122099" xrefstyle="select: nopage">(122099, DCM, "ST change from baseline")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c85f42be-15da-48ba-b1fb-ab9f7f12d1c0">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9d10ed89-2de1-4852-86b9-0316db74a71f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b62b2a46-dd35-4266-850f-75c1bfdcfaeb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d33110c8-09af-411c-94d1-b2df681aee5d">UNITS = EV (uV, UCUM, "uV")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac55ad28-932e-4bd6-832c-5af009751e0f">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e934f54c-736a-4dc9-9f47-0485b6d47875">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_612eff5e-6bd3-4d06-919b-f1da0a508938">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d10f4ab0-3942-4418-abe4-7d33f7c79e50">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c6c8419-29cf-4dd2-9baf-7fd496c70044">DT <link linkend="DCM_122148" xrefstyle="select: nopage">(122148, DCM, "Lead ID")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_11f6eaf0-ae14-447f-8e61-ccb133f1db1e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e48c87ad-e962-4b89-8339-117d32923cb3">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_15bf4924-43dc-4d73-bc53-a52bf55482ff"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1954900c-f67f-491d-a40a-75811d902f7c">B<xref linkend="sect_CID_3001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
        </section>
        <section label="Quantitative Ventricular Analysis Report SR IOD Templates" status="2" xml:id="sect_QuantitativeVentricularAnalysisReportSRIODTemplates">
            <title/>
            <para xml:id="para_bbb26af0-d0b9-4c3d-b541-413d11dbdd2d">The Templates that comprise the Quantitative Ventricular Analysis SR are interconnected as in <xref linkend="figure_A-3" xrefstyle="select: label nopage"/>:</para>
            <para xml:id="para_288151bc-dea7-42d4-804a-11429c148e2f">
                <figure label="A-3" pgwide="1" xml:id="figure_A-3">
                    <title>Quantitative Ventricular Analysis Report SR IOD Template Structure</title>
                    <mediaobject>
                        <imageobject>
                            <imagedata fileref="figures/PS3.16_A-3.svg"/>
                        </imageobject>
                    </mediaobject>
                </figure>
            </para>
            <section label="TID 3202" status="3" xml:id="sect_TID_3202">
                <title>Quantitative Ventricular Analysis Report</title>
                <para xml:id="para_6d55d887-c9e1-41fe-9b9f-77ef1952066a">The Quantitative Ventricular Analysis Report Template provides a CONTAINER with a structure for reporting the result of the ventricular analysis.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_1073f76d-b37c-4235-8562-840f4756d5fb">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_2f4db264-e04e-408c-bca0-9fb5df7cbbd7">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_c86cad39-f23d-403b-bb08-954cf76e4c84">
                                <emphasis role="bold">Yes</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3202" rules="all" xml:id="table_TID_3202">
                    <caption>Quantitative Ventricular Analysis Report</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_613a4ff4-a10c-4db7-8224-33f84912d880"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_70d92ef9-aa26-49e2-bd1b-eec9a3dd1332">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e188cced-7a13-46a4-a079-db18e04a0d17">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a081f35-93fa-4781-85b9-16497f53b3f8">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c93bbf8c-17b7-4b98-8aea-d90cdb43e7e1">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e6770f5d-1695-4191-bb4b-07b9d997b229">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5989678c-db26-4ae4-b858-3ade156c34e9">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb457473-c6ff-48db-a839-16bd86e82bdb">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6e8140b8-1c55-4daf-b452-c3c1e5f8aaaf">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ac4cfca-bcae-4ab4-8b82-9b2ce47dd413">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ab9f090-e751-4764-8380-92724e013b3b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a309b4f5-226a-468e-a423-e88d65ea5a36"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5774af06-a4ce-4dc0-8c7a-553a3c0cd9c2">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2319d0a8-7fa0-4a65-91a9-89abe61c54d1">EV <link linkend="DCM_122292" xrefstyle="select: nopage">(122292, DCM, "Quantitative Ventriculography Report")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e8104b1c-2d40-4f3c-9c3e-8cc1dd93435e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b43a362f-126e-488c-8407-5c461e03ae54">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26f96672-6633-473c-9842-b502b3781f0f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5dca2a38-90db-40de-b767-5e4ac894c608"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93ae28f6-399f-4a89-bc64-b8b4a638f482">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c6997e7-ea3e-400b-89d3-b4eec5bc2031">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_749057bb-c6dd-451f-9c09-5d731d424971">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c48a7edf-4fed-4155-bd12-f08e67b1430b">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc6d70cf-5d47-42b5-9893-4a56e6e112ff">D<xref linkend="sect_TID_1204" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d74bc283-6c86-451d-88fa-55e548de90c0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6cad25f8-7b22-4673-9072-6b7aa9a25bfd">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_986be72f-1a4b-4b4d-80eb-97686e224638"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e249fe0-c73b-48f4-94ee-53fd50e14438"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1aca1891-3007-42d0-b194-82497a49958d">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c0cc465-8464-40d9-8519-bb3ce411a82e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_33caad88-4ef5-4a76-9555-28ddae760d33">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7e5f5b6-866c-4898-a6cd-c675a61de82d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b352c573-04e3-43d9-a785-ed7ec4e7f42f">D<xref linkend="sect_TID_1002" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a977a87d-5779-478b-acce-d5995d3575fb">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_355b5129-1e34-43b7-bb96-cb21477c96ef">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d452db2-f7c1-4224-a342-407a87613944"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d09bbf2-e4e4-48c9-9cc1-93523fad7f43"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e5dee37-a61d-4e8c-9d37-5b726d01ede6">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_517e8d0d-eb1b-4188-aecb-2b20494c226b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27ca4cc9-58c3-4236-897c-794402f6547e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb9676b1-bf90-424e-9ea5-c5829276b7cf">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef824948-1dfd-43fb-8975-4f190529f0cb">D<xref linkend="sect_TID_3602" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f0aa0445-c163-40bd-b962-f604951d69b5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2c1dcec0-b150-4167-a2a3-fe48762e216a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c0e2d5a-a67a-4000-a795-78f23790ab7b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4699d348-039a-4e68-8d4c-76653820b8d4"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96dbe006-6a78-48d8-9e3e-32646f3a671d">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c3a46008-8ad6-45bd-b8e8-85fbd6bfe420">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f92ebf5-5a5a-4a97-b5d5-528fac3abfa4">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d33bd1c2-8ac7-4dff-95db-5228f4fc89e5">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4419e2b-134f-4718-b29d-9b66487a1f6a">EV <link linkend="DCM_122144" xrefstyle="select: nopage">(122144, DCM, "Quantitative Analysis")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4788d3df-e24f-42cb-a853-51b431b3641c">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c0403e97-305c-4410-a981-333907558c9a">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f90003c-ad55-46dc-a709-5609ab8245d9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_489a1888-1768-4f34-b179-8f719168a6a9"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_594d18dd-f134-4270-9686-f872a81de8e0">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_14555d56-56a5-4729-96c1-52c9fca72ba7">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc2416e2-9e0d-4882-92c6-97d2dd4c46b5">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c206cf1-ff64-49d7-a37e-2719d295a8f9">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9724bd27-76e1-400b-97f9-e25048fa4b0a">D<xref linkend="sect_TID_1002" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e07ea937-04f5-4633-a25c-c0f5caa6da37">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_78007fbc-1a0f-4835-a00d-b651713240d5">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75b146c5-2ebb-440d-8065-6b3cab2e5786"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83d5590f-61d4-4199-9054-b89fb1abd95b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9504209-9765-4f34-a63f-de336d6035e1">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ba7d35b-fc7a-46f3-b4cf-4f327df5ad42">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f4781a7-1c51-4f6a-8ba4-d440aad4397a">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d2e5235-17a4-4955-a387-5ed6532c5aad">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cece784b-ba9b-453a-a003-aae509f7e2c1">EV <link linkend="DCM_111001" xrefstyle="select: nopage">(111001, DCM, "Algorithm Name")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3be772cf-e97b-436d-9d47-ba69140ce57e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6fca9221-b64c-47f4-8d05-a90a47f35bae">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_acba70cf-6824-4c5f-9b3d-bc04bc4789b3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0fbe6b42-661c-434c-be78-368023f8ba63"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_209a2dff-81e1-4f7a-a3ca-b2f0988cb9ce">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_95853bc4-2f9e-499e-8821-42f58a55b4e8">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b55347c4-6f8f-429f-8a26-b66f902aad88">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88492a51-597c-4d30-b9ce-11767636a078">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_daac32b5-9139-428d-bbd2-dfe5801fbeda">EV <link linkend="DCM_111003" xrefstyle="select: nopage">(111003, DCM, "Algorithm Version")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f58c5fbd-ba35-49e8-95b8-d600fc63a40d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5f03e786-64e2-4b26-aedd-4c7dbdc01ce4">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_193d525c-7033-4dc5-bdf3-35e503046ade"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79883745-426c-4789-843c-d62e032a9319"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92d985fd-27a0-4547-900d-fad2986ca705">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b07adab3-d455-4011-917f-f63630a766b4">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83cee3eb-fa12-4d6b-aa9c-0d29eb5bde61">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43026b6c-f906-4fe8-b36b-2e37af9ba3c1">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9cbf7c88-e1b9-43c8-bb70-b233691db75b">EV <link linkend="DCM_122405" xrefstyle="select: nopage">(122405, DCM, "Algorithm Manufacturer")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e850bfec-af6b-4ce7-b623-83c4488dfac5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_084d7671-e016-4607-a7bf-63fe2beef381">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1eb8629-9c16-4aa3-8176-32bf0413d3b7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6eee3922-b4a2-4f5d-a5c2-132a927eea98"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ba8f9ef-a840-4096-91a2-60f750fc40b4">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1200b48-8266-4510-903c-f4d73c447426">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a8ff666-37cd-477c-a0b6-f9c3276f8c59">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_506c2b56-07d0-4ecf-a373-553eb37e778d">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e457ad24-dd22-4d0d-b568-20408ed9c68c">EV <link linkend="DCM_121112" xrefstyle="select: nopage">(121112, DCM, "Source of Measurement")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_48af842e-cd7a-4513-be4c-345274f3c34c">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4e690f31-268b-473f-883d-f4775faf5814">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e476c652-a231-499f-9337-8672b6588b40"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4aa8fbdb-45db-497e-b7de-e70f8daa0300"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_713615b7-1713-44d9-8fde-a29d52073ccc">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_352cba9e-159e-4c8e-bec5-3bc8e865cebb">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd10bd37-6b70-4d81-8e85-9017a6d5f914">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ffbefd5-f70e-4bdb-ae81-b37afb0a22d0">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67892383-571b-4797-9ab6-49a331fb2680">EV <link xl:href="http://snomed.info/id/246092007" xl:show="new">(246092007, SCT, "Cardiac Phase")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5663ccf7-0708-4171-b93b-b89ab61a4ebb">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0c705a52-030d-4159-aff8-f8657bccd914">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe0268b6-7038-4bb8-a6e0-b4b3f7f16619"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf0c7c3c-72c1-4915-8610-53a719ead8b7">D<xref linkend="sect_CID_12233" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cfb87ac6-e03a-429f-9693-a38dcd908b29">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4cbda042-a516-49a4-a781-0b029c9f8cd6">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b112112-bc03-4e43-b4f5-e5b9698655a5">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4042e0ef-dc73-417e-ae85-34bbe9a66e6e">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_568276f9-485b-41ff-ad1f-947161ec4606">EV <link linkend="DCM_111031" xrefstyle="select: nopage">(111031, DCM, "Image View")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_900a57ba-0adf-4a53-b612-4257022db668">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2839596c-8b68-4057-ba7a-a9cada96d0d4">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7391858c-fd4d-42f4-a2bc-c73082ca3200">If Biplane Analysis</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_867f5d72-89e0-4229-a96c-b1bf08f74c36">D<xref linkend="sect_CID_3466" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e2e0890-4b94-4341-9635-e6edb54da8ba">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0390ec70-3659-45f2-bb4e-38e62f6ba5b2">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_12ba2290-d0ca-446a-86b8-a9c237abd70c">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eae9f30b-d332-4d1f-a928-b3d125ae9d79">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59f77f9d-54fa-42dd-8f92-5b47aab30b6f">D<xref linkend="sect_TID_3205" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_df24b892-3212-473a-8642-eb923eda1a9b">1-2</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1247d4bd-0187-4afb-a4a4-321e44b74acb">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_924e705d-f84d-48c1-bc82-ad1c926c830c">VM = 1: Single plane analysis, VM = 2: Biplane analysis</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3596afd5-6aff-421b-af0a-b2c3120e34b8">$CalibrationPlane = D<xref linkend="sect_CID_3466" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0039c9a-e1eb-40bf-b988-d07ac7e7fdfd">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bcc6c94e-80e9-41ff-afbf-9c4d76b9c463">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_042f8a66-bb29-4845-bb5b-7adc0c65ae11">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2cd97b57-d7c4-4401-ad59-73b2b6e6e65c">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_40376bdc-fca9-4ef2-b52e-b84bebe7e715">D<xref linkend="sect_TID_3520" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f84b5e8-b03a-4bdc-bcef-e6441906a048">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_60f79f1c-2b11-445b-93e9-a3e00a43ed0b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bef991d7-f1b3-4b2d-920d-a69603229132"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c41d8ae-123d-4aa6-a59a-068e9fd7ffd6"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8feccae3-bc62-414a-8586-d52fa9a3bd33">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d4d07d48-ca96-40d2-ad9f-dd04888a1ba6">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69cd1250-88f0-479a-90f2-001b06e14d94">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36c8356a-c3e7-459f-b972-1c39790be818">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb2b5a80-2e9c-46b0-828e-90c05db1bc45">D<xref linkend="sect_TID_3206" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7151313d-eb81-4f3e-ac25-fba4dc6b76c2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3000a1c9-4837-4420-b936-6f6219115b50">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_534ca390-4a7d-4dfc-8964-7e8fe59eb28a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3904bf9-9c40-41b5-bd50-045420ea5ed6"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6004045f-1464-41a7-b396-f6def2ac6ed5">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6e2b69d-8316-4cf5-a367-1c1523f1f8b4">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63d4dc3d-9291-4ded-9169-501c2c26b1eb">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_772ef642-df2a-4af8-8665-ccf0545e7a58">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9f35fc6-1e06-4b5b-bc51-8fee68612aab">D<xref linkend="sect_TID_3207" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_93739cd5-4b37-4295-86fc-2c052113f459">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f61a952-df58-4a63-954f-7d6839f1209d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_992f6049-2d32-4474-8203-52e00a0e4d4d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4164b13-b8aa-4552-bcfc-ef27a7ec3c0b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d0f6226-ef49-4f7f-a5fe-546164e5bc29">17</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b7d07fe-e737-4d90-876c-81a0af86fff4">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_823259e1-946b-4d41-8fc6-f72aae80fbcf">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2abb55ad-14e3-46ec-a284-d2ed52454c7c">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92cfecfa-6b82-4a80-a69b-5074d9d2c2a2">D<xref linkend="sect_TID_3208" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5b7872d2-7758-4392-84e2-468c492172d7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2446d486-0f60-418c-8fbf-96239065ac42">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5853c91-fc87-4bf7-9db8-819e82d9c4f6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61a737d6-20f2-451d-b326-484c81162ae2"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f77b1b0e-c456-4968-9a9e-67b35d020ddf">18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_038585ff-f663-403c-8fe9-297f6fcdf598">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_afb3754a-46a1-43fe-9111-b8d68d1727c3">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80304cba-5473-4816-9b77-9c3123cd9c28">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fff02c76-7b03-4914-b210-dac6d07bed67">D<xref linkend="sect_TID_3209" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f45a270a-0b68-422c-a6f7-6f84cedeb150">1-2</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_53e277bf-7706-426a-9890-e079e910d13c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e11d199-396a-4949-9e91-cb3ccf44b8d3">VM = 1: Single plane analysis, VM = 2: Biplane analysis</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d505a970-e055-4592-8406-563956f7aa51"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16f93433-b45e-4ea6-b8fe-799dc6d0cff9">19</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05b3ab8c-3888-408c-9538-de1e9982894e">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c51e488-70c7-400a-afca-4fe95ccef03e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_afc33241-a4cf-40ec-a2d1-33a21a108c1a">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e90db5a-430c-476b-90a0-06b3540c2876">D<xref linkend="sect_TID_3210" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e716efb6-5b95-44da-9556-9f2ee161f079">1-2</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b04b89d9-b8fe-4e73-92ad-1ef1e101259e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f00a5d3-ec26-415f-9a93-410fb174fda1">VM = 1: Single plane analysis, VM = 2: Biplane analysis</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_999c85da-4d38-419b-b61f-b1a689dff1a2"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27e66bfc-b69b-4d85-a2bc-bb110dc90818">20</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b16328a-2849-42b7-b6b0-99494b76e9f0">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7763b3c3-1618-4125-9b4c-8878ab5cd27b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_812a0c74-ec1a-4c07-b1fc-247406dd76a6">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bca232fd-9720-4600-ba7e-75aaaa9f6baf">D<xref linkend="sect_TID_3211" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_baf4ca65-8495-4a89-8af1-27ece2010979">1-2</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4475d3b8-49fe-4010-b550-e2474da113a4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0dd316fa-c302-46ab-a8b6-8d5004ecc578">VM = 1: Single plane analysis, VM = 2: Biplane analysis</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8bb73843-f5f8-462e-b0c4-c2c0e8ae53c5"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_c44f6f5a-601c-4ea0-999e-246bdeeef9c2">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92d953c6-3473-4d02-aad1-e5f320b9f51b">Row 7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_feee2dac-655b-47eb-883c-0f98129953fb">Identifies the Ventricular Analysis program</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_19e96e78-855c-431a-af63-dc1802478472">Row 8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54e2073b-a652-4be0-ad43-bddd3d5dd1be">Identifies the Ventricular Analysis program version</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_01fba4b1-4df2-48f5-b695-d92ea65e39fa">Row 9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_376400ed-d03a-4b6a-bbe4-3717257368f5">Identifies the Ventricular Analysis program manufacturer</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d74f5ab-cbae-4782-9ed8-a1457e733f03">Row 10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3500def8-d56c-4231-95b6-bfa78fb19196">Identifies the ES and ED images on which the analysis is based, for frame by frame analysis the analyzed image are specified in the frame by frame results (3208) Template</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3205" status="3" xml:id="sect_TID_3205">
                <title>Calibration</title>
                <para xml:id="para_5fcc802d-8ab0-442c-a5c3-4a7bd8269733">The Calibration Template consists of a CONTAINER, with a structure for reporting of the calibration of images used in the analysis.</para>
                <table frame="box" label="TID 3205" rules="all" xml:id="table_TID_3205_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c9aab9d8-76df-4510-bb7e-9796b0f480af">Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a484273d-2446-48b9-86bc-744e3a98ab4d">Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48050ec0-82e9-46ab-b035-fa1776a97ace">$CalibrationPlane</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_db158ed8-819b-4a78-9e73-87f690c318e1">XA Imaging plane</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_24ffc47f-d62e-40f7-b223-8ac932099448">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ac7713d5-063c-4ca2-be54-3a897396b513">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ede72e61-7434-4aa8-a2d3-17d4222d0215">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3205" rules="all" xml:id="table_TID_3205">
                    <caption>Calibration</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5ed1a3cc-34fe-4974-bca1-0ef8a3deb7a3"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2b61c7ff-9ee2-415f-b6b0-459d0cbfd8fb">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3dd17481-854c-4b6c-a6f5-5ba1d8dc2795">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69fc5a09-290c-44d5-a0f8-2878f80cdd6a">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_87d774c3-586d-4ddd-9219-5dbbd6e33e0e">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9e689bcc-bd33-4cb4-9471-18f99d36a2f6">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6a260b39-911c-4636-8dc3-6451c9b33012">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b9eae925-660a-4b9d-a65b-d8474720c797">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a31b4f32-1023-4d0d-8901-1bb53c985610">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27904cc0-5b6d-4506-b988-a3e2de08d48b">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e90302f3-5a7b-41a9-8165-cabb81f26b83"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7ebb8ee-29e1-46d9-a791-0cfe6d1f37b6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da02ab3f-f7e6-4b70-adff-0d22c51ff518">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba281516-7509-47f5-a8fb-1050e01e46c8">EV <link linkend="DCM_122505" xrefstyle="select: nopage">(122505, DCM, "Calibration")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_43f39f84-c64c-4c7a-8381-bb7f5137cab5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3646cf6b-5199-431b-9d9c-db93a1caa3f4">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_930488e4-75ee-43e1-9c95-a1d48d3f78f0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4cdf9aa-c7fe-43ed-948b-49a9263678da"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f2997e4-ef6a-4818-aab2-32f2c87b8448">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_843e5916-c640-4ae3-8862-9099f53aba10">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ea64ad7-6148-49f2-ab4b-0304090d7994">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e70e091-f9e1-42c5-8d68-fa0c13faa67e">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5265965-9f7a-4d90-800d-ba98276b0d8f">EV <link linkend="DCM_111031" xrefstyle="select: nopage">(111031, DCM, "Image View")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3b4c806b-1608-4139-be37-9099d2582071">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3292d732-ddec-47cc-913d-765e6e86d6f3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_819a0fac-9f58-49d1-a3e1-249f066d962a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81613c39-56e2-48c0-9cca-e540b1953c77">$CalibrationPlane</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c1d5f3f-7a59-46c1-a3d7-d9e040e179b6">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b098654b-b5c8-4ca8-bab1-15b5ba661982">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f7adebb1-7eab-4aaf-bf5e-ace12c6e257d">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_efe6bc4f-90f5-42ba-b59d-de34c153dcb8">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_225ac9bc-a5a8-47f5-96be-d6454ca76b2a">EV <link linkend="DCM_111001" xrefstyle="select: nopage">(111001, DCM, "Algorithm Name")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85735ae2-4390-4703-b5b8-b26adeada654">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d56df11d-c657-4f90-8b17-9bf2f541ec0d">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_090a39d6-af2b-4832-9fdb-dbdb0f2d0d6a">IF different from Analysis program specified in the invoking Template</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a021c0fc-e667-48d0-85ba-9ce94928de9e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7d5141e-04e0-4a02-9147-cf36ee5484a2">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4caa98f7-690a-4ba2-b868-22c81922d5d4">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4641a5d3-0dd9-4bbf-9508-92e8f0cc164b">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29ee55f9-2216-4cd3-ab58-d1955c02b6b9">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6fcd7b86-a096-4dfa-b18f-dd0d1d761653">EV <link linkend="DCM_111003" xrefstyle="select: nopage">(111003, DCM, "Algorithm Version")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b588ddde-a7b8-491b-b9cc-f693e257cbe3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_65f6b1c4-1c03-4aa9-a74b-1f6e31b21ef0">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_66f1083e-2dee-489d-b001-08d27c1dccd3">IF different from Analysis program specified in the invoking Template</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ebdb7311-7f47-47af-9a1d-9142bd5d2557"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b25ce5e7-5d74-4859-bf46-6b650627ddcc">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62b54356-559d-4816-96d6-5ba9079a52e6">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73ca800d-033f-40f5-835d-89f41597a252">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a0754a0-69de-4500-ad50-3cb89b37ff80">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5260f2a3-ba7a-47b1-8e52-b913be618088">EV <link linkend="DCM_122405" xrefstyle="select: nopage">(122405, DCM, "Algorithm Manufacturer")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_618d4b1b-8359-4e29-a149-4edf14ff6055">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e8174244-d4e7-4b8b-8146-c965f85db879">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93c54052-2c79-45fe-8fee-b213fe4b8b02">IF different from Analysis program specified in the invoking Template</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b0a4da5-e2c3-4525-a80e-6ee37e876232"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04c0ab0a-7462-44d3-8589-f8a1b86b7ca9">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b9e351ba-e488-448d-92b1-555aa647906a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6089182f-d99e-4186-8973-58390684ca08">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e0016e7-09a6-484c-813f-2e099d5f193c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d2806c59-54f0-4449-b6d9-3dda690a562e">EV <link linkend="DCM_122422" xrefstyle="select: nopage">(122422, DCM, "Calibration Method")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fef5faf6-09e9-43fb-b305-b2765ece5a6a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4b424302-ca7c-4d5d-a386-69947e161edd">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c63416ed-a00b-4f68-a7ba-ba9383200cbe"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a49c925-7211-4f69-b9fb-48bb27ce6a64">D<xref linkend="sect_CID_3452" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_64376ac4-2517-452a-b172-48f2d9be5ff1">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ecfcac3e-2244-4179-be38-30416038eca8">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7720bd5f-ae69-498c-8d36-630680aef901">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73ec8634-8608-4d81-8523-7ffe9ad32d58">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50e35f3b-4d84-4795-93d3-c39e76b77aff">EV <link linkend="DCM_122421" xrefstyle="select: nopage">(122421, DCM, "Calibration Object")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_191f18c0-28ec-4c3a-b820-a6ae7a06be93">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_36d35e78-e0aa-4242-87d6-02236b07b19e">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_32430ad2-1e32-4232-a77b-513c17d24426">IF Row 6 value specifies Calibration Object Used</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c2740c2-6829-44dd-abc6-6653ea489846">D<xref linkend="sect_CID_3451" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d548cce8-90ad-4d7d-b624-a0e604c3a310">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d70cb0a9-bb86-4804-85f0-de57148a2b99">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_32194cf3-0149-4bbf-91e1-60967343ca92">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c3a1bcf1-5ee3-439c-ab4a-8eb0259bdf44">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a542e650-d65c-46f4-8510-fabb384ced05">EV <link linkend="DCM_122423" xrefstyle="select: nopage">(122423, DCM, "Calibration Object Size")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7601516a-1d3e-4d33-b366-3b58a9142edf">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c69c83fb-dd1f-4ead-8f78-580617f83f32">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f39a3676-e41f-4aaf-ad0a-d1de94ecd841">IF Row 6 value specifies Calibration Object Used</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc3d0020-5f98-4b41-ad77-5614081c0844">D<xref linkend="sect_CID_3510" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_627bcb4e-5c6e-41f8-9209-1883e2138b5b">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fcc4ab4d-2a07-4519-a5bf-057c32f8284b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ed2ab6e-8ee2-4d90-80ef-e78acdde0b25">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6913af70-ad14-47ef-8b68-29698a5e744a">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6e1752b-2582-4175-8123-4d2439ce203e">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e77e5af3-ca83-46d2-8ca4-192a2ad88130">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1426be32-342f-4316-a4cb-780c1447e420">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d7c2de7e-889f-49e4-ad76-5a4e576e6ff9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11cbd94c-6d88-40c8-8d09-77b2bdbcec85">$Measurement = EV <link linkend="DCM_111026" xrefstyle="select: nopage">(111026, DCM, "Horizontal Pixel Spacing")</link>
                                </para>
                                <para xml:id="para_0b80cd80-f651-4818-849f-6598eaaa65a4">$Units = DT (mm/{pixel}, UCUM, "mm/pixel")</para>
                                <para xml:id="para_e48eb030-e280-4797-90da-739da4d29d58">$ImagePurpose = EV <link linkend="DCM_121112" xrefstyle="select: nopage">(121112, DCM, "Source of Measurement")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7a77458f-4166-420c-8ccc-93c585828934">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50677fe3-aa28-40c6-ad11-78158e4721b2">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3cc7eaeb-2571-4a07-b4de-56d155bb7d6d">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55ded2a6-8b10-46ea-98f1-77daaf5d5ac6">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0dc6dc49-e87d-4486-9ad8-350c57ddc423">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_153c2dac-b1e7-4923-ace0-fd406e3ca80a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4cc98275-b4ec-4463-a0fe-f3beede792e8">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9387c605-cb85-433f-a3b6-5cbbff99e8c1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f47b837b-ca86-4c85-9581-5a8c984be7e3">$Measurement = EV <link linkend="DCM_111066" xrefstyle="select: nopage">(111066, DCM, "Vertical Pixel Spacing")</link>
                                </para>
                                <para xml:id="para_65a0d80c-15de-4dfc-9003-c1850977e179">$Units = DT (mm/{pixel}, UCUM, "mm/pixel")</para>
                                <para xml:id="para_72c8548d-ae1b-4dc6-b6e7-a6d330c9efe8">$ImagePurpose = EV <link linkend="DCM_121112" xrefstyle="select: nopage">(121112, DCM, "Source of Measurement")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48537eeb-8917-4bad-a949-f24f5b72c3fa">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_577c4d23-b1bd-4558-a0c1-6d80d9164ec2">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55d14c84-8629-4fbb-a50e-d51c88d0c5d2">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a11e4a1-f6ba-477d-9cab-4bd77b85af0c">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd32602a-2e26-4705-abb1-6fab399db838"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ffc15005-3de2-4e94-9198-0c66ca3a1d6a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7d20e43-8053-4f27-846e-259477037cf4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21aacb53-2e8a-4a64-8a04-8fbd793178ee"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54899b4c-d97f-4d32-802c-46a597d1fb64"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_4a696260-f2e5-45b8-8ed9-3f8c8b3aba08">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_414939c8-22e3-4162-b811-ddbcd08d604c">Row 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f7beb458-1966-4b18-8c2c-13b990e54fe5">Identifies the Calibration program</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e31eab8-1c6d-4e7f-b649-72476cd8286f">Row 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51954cb5-6af2-46c0-92c6-2dbc13bdee88">Identifies the Calibration program version</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de01d67f-218b-458b-93a7-7192ead37198">Row 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_829d3438-5945-477d-bbf4-41b2e919da88">Identifies the Calibration program manufacturer</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1fa57c1-bc47-48d4-a02a-991c52226ff4">Row 7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b693eb0c-ebd5-4b67-bb89-a01c31f03cc3">Besides a Sphere and a Catheter, a Distance can be identified as a Calibration Object. In this case a distance measurement of a known dimension of the object is used to calculate the pixel size.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_140a01bb-0415-4852-9c21-56601f393e9b">Row 8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc91b37e-7481-47d4-aa06-6848b20f5aff">The catheter size units is also used to specify the size of other calibration objects (e.g., sphere)</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7a9d95d2-c93e-4424-8200-7ee164d3f4bd">Rows 9, 10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c6129971-6d79-4e3b-9c44-3567945bb559">Spacing in the patient body. Point to a single frame containing the image used for calibration if applicable, the actual measurements may be indicated by a SCOORD (see <xref linkend="sect_TID_320" xrefstyle="select: labelnumber quotedtitle nopage"/>, Row 3)</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8fe249a0-9245-456e-864b-40c6255b5050">Row 11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ca69aa3-b81e-473e-8c3f-30d93c6558fd">Secondary Capture image with calibration position. No purpose of reference is specified.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3206" status="3" xml:id="sect_TID_3206">
                <title>VA Main Results</title>
                <para xml:id="para_95b24519-2967-4000-b824-c46fb903d585">The VA Main Results Template consists of a CONTAINER with a structure for reporting the main ventricular analysis measurements.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_1cf1a5e7-a7ec-4f87-84da-7ae74a5c009b">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ba108601-812d-4136-9fca-ba914962400f">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f6de827e-6db3-4f3b-95c5-12bdd6d15659">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3206" rules="all" xml:id="table_TID_3206">
                    <caption>VA Main Results</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ec82f963-bf96-428e-9bfd-43f69d1ddb26"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cc4436ae-e4cd-46bd-84a4-22b68f3b54fa">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_56cde304-4c5d-452b-9087-71e57829870c">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b1d963bb-bcbb-4e02-8fd3-80ccc215106d">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5b8289a3-3d48-40d2-ad66-11f8d365d64f">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_307c5d1d-6d82-44dc-ae2a-1f6db0e16ab8">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1400ca5c-f44a-43ef-b67b-c0bdc3546199">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_faaf919b-6cc3-4211-baa4-aa7230706459">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_40f7b07a-2991-4da9-88e5-4885c82f3817">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_117b1515-54be-4cfb-88d7-86d1781dc76e">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79ec6033-ccae-4581-a5f0-567d50d797ea"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4075d7c2-f1ac-46fe-bbb0-1ae88918610e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04eb2fe3-f01a-49dc-a683-bceac2a900f0">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa898146-4a02-4adf-9c78-8be1a042a570">EV <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c52bf1ea-7cbe-4e9e-9ab7-2ff543e8f16b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_21b2949b-17b7-44e0-b159-a9eb4180920f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0eec260e-4505-49c5-b842-45fd454c0c38"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b36f2e9-7e45-4443-af06-ee465a25b0d0"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d119e227-977d-4a47-bb37-767432bc4eed">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_376fbe52-1bb8-4279-a6e0-90b9346663a6">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_14f8fa65-8d82-4364-b788-94e6ff52af54">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04c1ccee-75e0-48ab-8073-00bc4ff9d55e">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f537ce6-32cb-4087-a8ca-058263cd15d6">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_35488215-c2ea-47e9-af5b-f06cde381f65">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b2f9bb6b-f8b9-4817-bece-44b6d3ba4ba1">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_418fbe34-5ff7-4053-8eab-27c2ef7b71bf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74b1c846-88e9-4107-b89d-d186640bad7b">D<xref linkend="sect_CID_3462" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_404ce940-3a1c-463d-b533-166db9c06003">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b973e88c-cfbc-49ec-bb99-3b2d2c33fe86">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_651bcb6b-033a-4cf1-afc9-2e74b275a335">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b6e4ee3-0fb7-42de-885c-e88844a6de38">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b057de1-3f11-4e0b-b632-d0b5b0f640ab">EV <link linkend="DCM_122429" xrefstyle="select: nopage">(122429, DCM, "Volume Method")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_370ede12-d9f1-4ddc-a8e3-2633159ebbba">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e8b0bac9-d30d-4012-9c53-048a371ca619">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0d0e888-7901-4d0b-8122-e8303440298d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5821dcca-928f-4b50-b824-8ed413779613">D<xref linkend="sect_CID_3453" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9622854e-40b5-4a7b-8791-2bae5831a5a2">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_15a4314e-956f-4553-a3a9-364b2ee75749">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cdd9c79a-fbf7-4f1d-bd16-b492a9afa829">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69507a0e-118b-438c-84d7-80beb330a308">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5eb219c-c83c-43d2-b602-7688d84ed379">EV <link linkend="DCM_122435" xrefstyle="select: nopage">(122435, DCM, "Regression Volume Exponent")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2bd7183f-271e-4a5c-bd9e-d82f52030269">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f6aa8bc8-f214-4bb7-9f38-04f03a7ce707">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21f4d5fb-60d4-4b52-87f0-c750409eb33b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_934c8508-3e12-442f-978e-7ce23d6560ec">Unit = DT (1, UCUM, "no units")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d69d0860-a5c1-4a5b-a7fb-af01989ef77f">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_475440a8-6e6f-4eda-9154-e7a23d05c78b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8d142e7-0a1c-4a25-8acf-5d9720266d72">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0205038c-29e0-45ce-ae80-58473df1277c">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d07d315-e99e-4485-99d7-44e997de020c">EV <link linkend="DCM_122431" xrefstyle="select: nopage">(122431, DCM, "Regression Slope ED")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_850430d7-fecf-4587-8aff-b7620150a96c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ac811624-6f38-4e50-8747-18db9aa88d84">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48b1b221-d742-4348-92d9-582a6997455f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_929923d2-70c1-4df0-b174-0a60f4aff819">Unit = DT ({ratio}, UCUM, "ratio")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e68fbb23-7b8d-44fd-bb2a-3ebf49010ce5">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc9fcb9c-8d83-4a83-b1b9-b072e350a0a9">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_45498fbc-d36d-47f0-9d1c-9f9387e9484e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_41dfbe46-49a9-47be-9859-bbe9819f5d0d">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75798422-8f49-4cea-bfba-99775a8b54ce">EV <link linkend="DCM_122432" xrefstyle="select: nopage">(122432, DCM, "Regression Offset ED")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a75d2c8a-eed8-461f-89ed-2c2264eefc0f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8c0b2af5-bbae-4fc9-805d-fd9f92557bdc">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5068fae5-83e9-4ae4-80a2-0150066e674b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7899201-4baf-45d4-9e7d-27d8de047876">Unit = DT (ml, UCUM, "ml")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93d2b516-e157-4e08-9843-e045a6dfb6d9">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b40f397-8387-4f1b-93f0-f3f87b0fc9d9">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3172de9-2990-4293-a372-fcd18b78960f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f101c7f4-4420-489a-b378-c90dbdefbbfe">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e1b040a2-4ea4-4ee9-854b-c233a8f3a88d">EV <link linkend="DCM_122433" xrefstyle="select: nopage">(122433, DCM, "Regression Slope ES")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8a0d9d7c-4faf-4c6a-a791-d078a2274fb6">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b0cfbfb6-0940-46bf-9803-985d1bf97643">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e540e94-f097-4fce-8dc2-3137b64af6f2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e4c0ab9-3f97-4229-a1e1-bef1d38cd7f6">Unit = DT ({ratio}, UCUM, "ratio")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f568ece-a60f-4883-af41-9746a8243e6c">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_428629c1-5014-41c3-9dab-3a882dbbbf32">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ab4c4bc-f007-4ac0-a944-6cfba9f270e8">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_304bc06a-26cf-4031-b62a-1ab3e59443e6">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e78aec30-2ada-41ac-b37f-57c03f1326f4">EV <link linkend="DCM_122434" xrefstyle="select: nopage">(122434, DCM, "Regression Offset ES")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_831c58dd-4c70-4141-a5ba-28ea7b11e15b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_31e509da-0369-4b49-b02b-465b9258b21b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bbcb974d-df0f-48f0-b9ce-e1cf11d36116"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83b04841-8d6a-4c2d-8309-e8c8228cc751">Unit = DT (ml, UCUM, "ml")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f4027e3-c04f-4949-97db-3dc0132c9f3e">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da235c8e-a38d-48ed-b8ee-7ab0226b4c41">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0dcf0f3e-0981-4935-8069-f36ea6c458ad">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a18d0bed-af50-44c4-af0a-16b8186e6b33">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f14afb8-1108-4985-a561-f30806f08387">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_030dfa07-e3f0-4a23-9870-15dff09dca89">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_edd2e664-b4e0-4bb9-8302-21f7cba54c8d">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b30daa30-fb0d-40e5-b0b3-c7c1c845e6c6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1912e782-2aae-4e47-89d7-11dac102ba82">$Measurement = D<xref linkend="sect_CID_3467" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_9ff15b03-1f0e-4809-9b29-c81970b39df2">$Units = DT (%, UCUM, "%")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_311979ae-fcc3-4b9b-be91-caf9f1c611de">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d634d84-9210-4be7-a5f9-66bcd2d23c58">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_702ded3c-8826-4441-b980-634ebb6f7e81">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_693f77a9-27c8-4177-9a07-8921d139a710">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c098fe72-384e-4ff4-9df1-9dbe61538076">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0b078834-c99e-44a3-a768-cb69f680977f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c0467a3-5349-43c7-8ebf-16642bacea7c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25fc8fbb-80aa-47e4-bb79-e62885df49fa"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_78400704-b2c8-4616-b31a-b5c7b1d2a131">$Measurement = D<xref linkend="sect_CID_3468" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_5143722d-293b-4aa1-aba4-dc8bf0e774a5">$Units = DT (ml, UCUM, "ml")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d3273e7-ab64-4e63-90b3-5b03c76a0364">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b72ec179-5431-44c0-b748-5ccf07845430">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16b2181a-7bfb-4580-b51a-6bd3c2ee6bd6">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6fe01199-e5cf-4ab7-b466-7216b4ea0114">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6da31efe-92ff-4d21-b31d-b59a184525ba">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ea3550f6-44b7-4a91-a2bf-525ff45e2eb2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_830701f8-8a83-475a-9b12-1541dca4d169">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ca92af8-02c1-42df-853b-30a9dc0db3f7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb5d39cf-4315-4efc-9721-4368f7ddf94c">$Measurement = D<xref linkend="sect_CID_3469" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_a44148f7-2a08-4737-b517-fff71e4648bf">$Units = DT (ml, UCUM, "ml")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f90f910f-3b2b-4508-97e4-c156f17db050">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9308b9ce-e60c-439f-a969-db2c256a86e3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_19e45923-9732-4d8c-9335-18676171265b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed84420d-35b4-4172-95ff-ebfe670b2068">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_184beae2-4466-4e9f-abc3-084cfa3d15de">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d380dc1-da42-4590-91a3-ee0b74977c79">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2080658b-4150-4efa-b556-f8c11d472618">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_64238484-1da9-4445-9d1f-3c03b82176ab"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d038a94-b435-49ea-968d-09cec679b857">$Measurement = EV <link xl:href="http://snomed.info/id/90096001" xl:show="new">(90096001, SCT, "Stroke Volume")</link>
                                </para>
                                <para xml:id="para_62d49b63-8ce0-4a73-9b1a-a28bdd534e7a">$Units = DT (ml, UCUM, "ml")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d37f1cc6-ea65-4927-a858-f4681490122e">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6db48e14-5c64-4c7c-971d-2c576da92639">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_deb805e4-2c1a-4c43-8aeb-6129dbe9d9d9">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb825c7e-7ef8-4a94-a814-7400fb698722">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c11a87c3-e609-4040-b86a-9bb81b89be0d">EV <link xl:href="http://loinc.org/8867-4/" xl:show="new">(8867-4, LN, "Heart Rate")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c5902306-be80-459a-935f-dd58a2a5fa3d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c76b1ce2-b898-41ad-8c4e-fe2170426c44">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_505c2372-fdaf-4756-989b-e30a27976bc4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a4194d3-d9b0-4388-9355-19fb25057389">Unit = DT ({H.B.}/min, UCUM, "BPM")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1221109b-da64-40a6-92e8-f4d0f93d2769">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ceda7f8-4e26-4de0-9c53-58f9cb826940">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1094d1cd-f70e-4c40-a14a-fa55070dd667">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2d58b7fd-b16b-4220-9d21-91fd6ee4059e">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ad492df-9af8-4b14-ad13-5bc11f3e5a0f">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ccb0b242-b957-4ecf-b6ab-3cd5f526b3b9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_254ec783-409e-4072-97bd-eb398896e3cf">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10101a43-80c0-4ccb-9bc9-0284b885966d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74be86c2-6332-4b3c-88b5-ec1ff7f7a2ad">$Measurement = D<xref linkend="sect_CID_3468" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_16446d6c-eb55-4ace-9c6f-c40d69eebd65">$ModType = EV <link linkend="DCM_121425" xrefstyle="select: nopage">(121425, DCM, "Index")</link>
                                </para>
                                <para xml:id="para_547d8d6d-76d2-423f-b31d-6b0984095bcb">$ModValue = D<xref linkend="sect_CID_3455" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_baedfcb0-ba81-4092-9761-9c1aed39c4e0">$Units = DT (ml/m2, UCUM, "ml/m2")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dcc3d431-295b-4657-a227-7c57750e30e1">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d02be9ed-feb4-4458-ac29-15447a30c447">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03ae4d0e-221b-410f-aafb-2fc2e3862ba6">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3528c54-dc3d-4722-8cb5-aafbb40fab4a">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2dead66-cd36-40ca-bbdf-63601339af1b">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7bf3ba4d-3425-45cf-b4aa-8d3778f6fa81">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7bc1225-5f3a-4d9d-9a8b-ac160de55cf8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b7beab9-5539-4998-9b36-4ec1eb520771"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69d8c3f7-e10c-4585-bfb1-b56c6c56a08b">$Measurement = D<xref linkend="sect_CID_3468" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_76fd8c10-f85b-4ca3-a1a1-294c26a2e4a8">$ModType = EV <link linkend="DCM_121425" xrefstyle="select: nopage">(121425, DCM, "Index")</link>
                                </para>
                                <para xml:id="para_7bddc8be-4380-43b4-be5e-18a90b858371">$ModValue = EV <link xl:href="http://loinc.org/29463-7/" xl:show="new">(29463-7, LN, "Patient Weight")</link>
                                </para>
                                <para xml:id="para_c7afcb98-ec48-4e5c-baec-f51ba9c9910c">$Units = DT (ml/kg, UCUM, "ml/kg")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57127230-b0ad-4244-a50e-f688c8ac345b">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_221720dd-1877-4af2-b833-2ebbd1eccb2e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_28f3ff7c-898e-42c1-b22f-acdc2f4b725f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0862d43-fbc0-4c89-8cc1-70206b663367">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80a7078d-94b1-47be-a612-a32e80ad1c13">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ea3cab4a-6893-4e3b-a7c1-fb382ffd8cbb">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f6a90d0e-286b-4a25-90aa-d19bf81fa207">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3c7a33b-cdeb-4cfa-a337-fdd403508a3c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3db9653e-2c04-4c31-ba82-3affc65a1d0d">$Measurement = D<xref linkend="sect_CID_3469" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_fecf4a92-8ffc-4566-9828-57ac5ed3ea1f">$ModType = EV <link linkend="DCM_121425" xrefstyle="select: nopage">(121425, DCM, "Index")</link>
                                </para>
                                <para xml:id="para_b329eca1-b795-41f1-acf9-4848ba3fcb90">$ModValue = D<xref linkend="sect_CID_3455" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_27f407dc-8889-4e72-8f3f-2618bf956f32">$Units = DT (ml/m2, UCUM, "ml/m2")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc149946-539d-485e-9ddb-d7c94a3e1d37">17</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab3be48d-3af6-462f-b545-255ea4ac35fb">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f28449c-4afc-4bec-bce0-db8807586229">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ef93105-a2da-493d-8415-86d8d170331b">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e41e8f7-3c2b-4a2a-b137-a6f21e376f7c">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_067897f5-38ae-4c47-aa9a-a17080721d3b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1a837d49-1ba5-4f6c-bbe5-bc3e4757d662">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a324cbdd-18e2-4aaf-935e-8d87d38b79b0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1b18a04-7ccc-4410-bb1b-a5741bb0b3e4">$Measurement = D<xref linkend="sect_CID_3469" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_b6c87625-bffb-4316-be19-83a958852eb0">$ModType = EV <link linkend="DCM_121425" xrefstyle="select: nopage">(121425, DCM, "Index")</link>
                                </para>
                                <para xml:id="para_7dd3657c-0786-4587-b111-5c1bbd74b1bc">$ModValue = EV <link xl:href="http://loinc.org/29463-7/" xl:show="new">(29463-7, LN, "Patient Weight")</link>
                                </para>
                                <para xml:id="para_0eec754a-8b0a-44a5-b4c3-b447a0d06310">$Units = DT (ml/kg, UCUM, "ml/kg")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_912fabb8-e552-4617-9a9d-102307bbbd7e">18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c085e6e9-924a-4170-876b-3960e15f5980">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5178eae7-ac18-4ffd-95c8-99cc455b2880">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b49385a-c873-4f58-aea9-ef0b7910ad3f">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_278d7a7d-a581-46c9-b669-ccce3f4d3f86">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_77b37305-22be-49fa-87eb-d6bebdeb4bc4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2fe5314f-b4f8-4a27-a577-6394291a9b58">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6bbb80c2-4c68-4f77-a9b9-0cbd9e5f5266"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6c3d72a-c482-4a38-b5ee-9bd36f62e406">$Measurement = EV <link xl:href="http://snomed.info/id/90096001" xl:show="new">(90096001, SCT, "Stroke Volume")</link>
                                </para>
                                <para xml:id="para_57662b75-9baf-4884-b260-213fd649d03b">$ModType = EV <link linkend="DCM_121425" xrefstyle="select: nopage">(121425, DCM, "Index")</link>
                                </para>
                                <para xml:id="para_69445ce0-a144-423e-8d79-8958d30495c6">$ModValue = D<xref linkend="sect_CID_3455" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_d3025e72-2647-4863-8681-c85da982afce">$Units = DT (ml/m2, UCUM, "ml/m2")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72ca63eb-e568-486f-9392-3a1a229b99a2">19</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75baaec9-aa89-441b-8ae2-1accfc43789d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6046b108-cd14-4016-90cf-597adf9ddf1c">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7076fc57-b687-492b-a37f-cc48e4e99664">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dad1746a-7bdf-4852-a43f-f282afc1f04c">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf0f1fbe-82fe-48ed-ae9a-6477a14de45b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3fe44594-a064-482b-b04d-05ef38496050">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5d9fe79-a0e0-47df-b0f2-77586cc16e18"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4459b266-8b53-4dc0-bd71-f2cbcdd92fe1">$Measurement = EV <link xl:href="http://snomed.info/id/90096001" xl:show="new">(90096001, SCT, "Stroke Volume")</link>
                                </para>
                                <para xml:id="para_a2b7d15f-14cd-433f-9f0b-e5253a313b91">$ModType = EV <link linkend="DCM_121425" xrefstyle="select: nopage">(121425, DCM, "Index")</link>
                                </para>
                                <para xml:id="para_002ed509-f1cc-46f0-acb1-8604857c41d7">$ModValue = EV <link xl:href="http://loinc.org/29463-7/" xl:show="new">(29463-7, LN, "Patient Weight")</link>
                                </para>
                                <para xml:id="para_ad26b932-3560-4d61-a968-48d644756030">$Units = DT (ml/kg, UCUM, "ml/kg")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63681188-114a-4a2f-b81d-e0d6c628851d">20</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2def4f1f-b55d-4cb9-8865-d2810897cd55">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26f3583d-77d9-4f6e-84b7-55f47dfe8f2c">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c6426248-f45c-427b-9c0e-871273a1bb70">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7887b2ef-acaf-44df-a4d3-0c925756ded3">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3bae53d5-4a1c-4f6e-8bc4-fa684735f62b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9a06e6a4-a84b-46fb-a5bc-0032fff6cee0">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_739ff095-7d9f-4cb3-9a29-2af1add34c65"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ac870c9-7ef5-4802-b478-19296e895e98">$Measurement = EV <link xl:href="http://snomed.info/id/82799009" xl:show="new">(82799009, SCT, "Cardiac Output")</link>
                                </para>
                                <para xml:id="para_04590daf-8dc1-4078-8843-65dc3abf7fb8">$Units = DT (l/min, UCUM, "l/min")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03fc8601-2a81-4558-86c0-1879d0f01262">21</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c70f26d1-e644-4a72-b465-fee397643471">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1fff592f-5a47-49b9-b8f6-5d6d960c9366">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17652350-b4b1-426a-bec5-4b0c0ffc1bbb">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_47d0b863-9f41-4bd0-ad90-3682f40482c3">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f6a7d75-cb6a-4432-be29-3a5a006f1e23">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b69e5a84-355b-487d-90d4-448fc7f65741">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5dba2fd5-74bb-4afe-a4fd-b1bdb5008e81"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4764effc-c493-44f8-91f3-78b08108ce6c">$Measurement = EV <link xl:href="http://snomed.info/id/54993008" xl:show="new">(54993008, SCT, "Cardiac Index")</link>
                                </para>
                                <para xml:id="para_572a1729-55d9-46a4-9c46-16f4627f7d23">$ModType = EV <link linkend="DCM_121425" xrefstyle="select: nopage">(121425, DCM, "Index")</link>
                                </para>
                                <para xml:id="para_42c7d029-2b2d-4b02-805d-82e6e628e686">$ModValue = D<xref linkend="sect_CID_3455" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_2ab63873-83b8-4021-ad8c-2f8d4b320c5e">$Units = DT (l/min/m2, UCUM, "l/min/m2")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f0b7977-41c8-4620-9f0f-13c5e9070b4b">22</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43fe7105-4926-4c74-a690-9de6bca9c568">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8833afcb-a1c2-4090-a9dd-16179c5e7e4f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0712f3f3-7c73-41a5-a94e-c78dd213e78f">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06f07eb6-94e1-4b25-93e7-bfca54644a25">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8d41a8db-b597-49bf-bfb9-2b257588adfe">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_50b56458-4f9e-40d6-a83c-cd587be1b12e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c8f1b3d-4fd3-44c7-81fe-d54d35048037"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_735215f7-3a7b-4bd9-a3f1-7819c46b16fb">$Measurement = EV <link linkend="DCM_122445" xrefstyle="select: nopage">(122445, DCM, "Wall Thickness")</link>
                                </para>
                                <para xml:id="para_e1782ba6-8079-4e69-a068-dff2e89e277d">$Units = DT (mm, UCUM, "mm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c2edf63a-fefd-477a-84d7-b04d379d23ac">23</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c2508bdb-516f-44e8-97e7-d7ffbe19f324">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b6c283b-e94f-4a7b-a822-87bc64da8872">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55f6e0fa-29eb-47fe-aaeb-67a8d342bda5">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a91829bc-99b8-4c66-bfe3-bdd9f4f2bf30">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f8badeb6-573c-48e8-9104-981e56083cc5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_19b288de-77d5-4a92-80ec-79221f15137f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b033a4f-921a-4c02-9338-cf0c397717de"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ff5ff43-5a66-48c4-9b37-359ea4ff2f25">$Measurement = EV <link linkend="DCM_122446" xrefstyle="select: nopage">(122446, DCM, "Wall Volume")</link>
                                </para>
                                <para xml:id="para_fe0a8af9-51fb-421c-89f5-4c514f12bd3f">$Units = DT (ml, UCUM, "ml")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b49e86b9-02ad-4043-8943-10cd51dd4487">24</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5dd8d977-3e77-4c8e-bb8c-dd89aae0c658">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_14e5caad-af50-408c-a4d5-e52df06def98">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1add5bd-3faf-4463-85f4-fa0afaab5f56">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0286c511-8c34-4771-8431-01f894b60e97">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_74683ab3-9a84-4cbd-a9f3-20d34847a6d5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf86fd20-cd5b-42aa-96cf-29e08323b0f4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7bc97d55-a703-4d4a-ac02-09839290bef8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fbe5c93f-cd16-470e-aff7-a995c4b3002d">$Measurement = EV <link linkend="DCM_122447" xrefstyle="select: nopage">(122447, DCM, "Wall Mass")</link>
                                </para>
                                <para xml:id="para_b60c6cdd-1b88-494a-b85c-113aa12a29f7">$Units = DT (g, UCUM, "gram")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6676e448-f545-419f-8e2d-ef27743c5cd3">25</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf44864b-a6f2-4a87-b78a-3a532b705ecc">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_375fcbbf-4400-4ce9-a81a-1462c6397949">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67247b6a-fd90-4262-8991-b02b1db3512a">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa2b77a1-9ebc-4723-9e9c-ad741b1fe1f2">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0eb31626-49e0-4c7e-8786-bccd1bb34538">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d9041cb7-fda2-4a97-9a66-3737a7ea179f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be1f8157-ddd4-462b-b851-8f47d3d669e1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8c2723d-136e-4091-a31e-05784ffe23b1">$Measurement = EV <link linkend="DCM_122447" xrefstyle="select: nopage">(122447, DCM, "Wall Mass")</link>
                                </para>
                                <para xml:id="para_2fc94f54-0810-4e5f-b475-ef7a8518c75a">$ModType = EV <link linkend="DCM_121425" xrefstyle="select: nopage">(121425, DCM, "Index")</link>
                                </para>
                                <para xml:id="para_097044b3-41cd-4abb-a3da-6440cc6d2c31">$ModValue = D<xref linkend="sect_CID_3455" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_2eb2ed3d-b852-4562-80ef-e0dd08e20003">$Units = DT (g/m2, UCUM, "gram/m2")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_56a19082-df4d-4b92-a0bb-e6efe2d203a4">26</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2eab2a8d-dd9e-4bad-8129-296fcee1feee">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d82ee8d4-d369-4903-a75e-4a559d5ab561">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce3dd59a-d1b3-45f2-9a86-4e6aadf9e742">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4e52039-2a5d-410f-8736-3267211cfeae">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_96068a9b-c9a8-4465-b213-9a4cd23634f3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_449679fb-9f90-411f-acaa-a8db0b09b3ab">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_320e64a6-48f6-4def-911c-3ce550ed21d5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a20bad20-e94f-4008-b1a7-7c520c0b0c51">$Measurement = EV <link linkend="DCM_122447" xrefstyle="select: nopage">(122447, DCM, "Wall Mass")</link>
                                </para>
                                <para xml:id="para_08257c8a-c65a-4a76-ac38-39c7f3ea6154">$ModType = EV <link linkend="DCM_121425" xrefstyle="select: nopage">(121425, DCM, "Index")</link>
                                </para>
                                <para xml:id="para_8a7c69b4-7a52-4666-84fe-d166f60033e4">$ModValue = EV <link xl:href="http://loinc.org/29463-7/" xl:show="new">(29463-7, LN, "Patient Weight")</link>
                                </para>
                                <para xml:id="para_2f1ae20f-97d6-4d33-8237-3cc4bb7d1316">$Units = DT (g/kg, UCUM, "gram/kg")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca650849-b7ea-47b2-a2d1-f809d15b63c3">27</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b952a37d-3c1f-410a-b08e-a93762c9cdc9">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c706927-e1d5-4112-9abc-8efe78ff2b81">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ffef8488-2ca8-485c-9bb6-db05397e81a0">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5e0fa87-6dd8-4611-8440-b8ed35b06afc">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_048363a6-7cf3-4faa-93d8-7863f1e13f40">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_be44e79b-107d-4834-a7c2-e8dda64224ec">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1a12989-77f8-4728-9699-a1cfe3306423"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_038d1079-b9e2-4301-ad52-e9fe9ca026a4">$Measurement = EV <link linkend="DCM_122448" xrefstyle="select: nopage">(122448, DCM, "Wall Stress")</link>
                                </para>
                                <para xml:id="para_2b37ae08-50bc-434d-a306-fe52800c9c5a">$Units = DT (dyn/cm2, UCUM, "dynes/cm2")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f739efb-767d-4296-88b2-4e2540585958">28</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a7c3949-5750-40c5-b913-7ccda6e1d2cc">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cff4ec44-642f-4ae4-8707-e0c367d51ed5">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b8851ef-665d-4669-97b8-932398912230">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13683ecc-921c-4db9-9233-35eef59ee755"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_42a44eb3-2aac-4ce1-9231-42a66aecec77">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a8333083-2db2-49f1-a8e0-5446777e5bac">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e053f2d-72ea-4ae3-947c-7927f8d1567f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aae2ac6a-2f44-4f01-b94d-776ede92a1c0"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_d613fe87-2a06-41de-9074-df77c50e0b68">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_398709bb-a401-4cc8-b5b3-dfb1e17ade93">Row 28</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4214be21-347c-4bb1-aeec-19b3bc512452">Secondary Capture image with ED and/or ES contours. No purpose of reference is specified.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3207" status="3" xml:id="sect_TID_3207">
                <title>AA Main Results</title>
                <para xml:id="para_71779d04-6a5e-48fb-b3db-24289350f917">The AA Main Results Template consists of a CONTAINER with a structure for reporting the main atrial analysis measurements.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_2606cd42-4042-4c62-a458-dd6cc8d91e90">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_630ceddf-7262-4992-b952-917832e4dd9c">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_58313f48-56b5-449c-a200-b1fdbf0658cc">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3207" rules="all" xml:id="table_TID_3207">
                    <caption>AA Main Results</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f5f88154-f5d8-4593-9611-09a4883496f0"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8cab4944-64ec-4a08-8eee-297cce75872a">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1125ee3d-24c5-4fc3-8146-a6df7aad3f1b">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_efa4e3e8-4ca7-4c4d-b828-29591d912e7c">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_57e0fe0b-53d7-4685-8472-42aa5d86bf65">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_40d9220a-799c-4b99-bf97-88c6ef4130af">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3e94d19f-b7ab-4e2c-9272-c1d56bb55e98">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_49743638-5f72-4646-8634-e8bd94381971">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ad9a58d0-de31-4096-9f51-1d78e1ead602">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5dea0736-e027-438d-9de9-896a51b28bc3">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd6d8346-5e28-4b78-996c-cc7a71002dd5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0fac531-92fe-4945-80e7-b46dcbe80094"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98488e97-3b3b-4088-98f5-bf87bdd2cd76">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ade0d04-2bd8-40ec-8cc2-c0e852f6b673">EV <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_da798aa2-989e-4983-aec6-95e6605f9a71">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fc305072-4242-4a28-b023-9a780ec662d3">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98e3aa65-b320-4f78-97bd-8e46008957dc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55300d9d-8b0c-4c91-b095-833bcee0d30a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a4141d5-f7d8-4113-a56c-d7359bdf327c">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_250b29a4-190a-4413-8a24-acf086582a10">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1586f881-68d5-4676-9486-22db5ca3e75b">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f712e980-3def-427e-9058-1acc24c36e1f">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1370ad2-2db2-402f-bc30-5e87b07dd5ad">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d92fb53c-0440-4ba3-9e07-9084645ac918">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_29763ef5-c1af-4123-9d60-faf5de0927f7">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63936dfb-4c41-4f82-9457-140eb99fd434"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ab7dac4-b334-434e-97d3-0dc81ec3408f">D<xref linkend="sect_CID_3462" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09ee7514-618e-4ba5-97ad-966cfc7c3390">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98b2a541-2a2b-4744-8be1-cbd648162fb7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c350cd0a-f068-4da1-a54d-a6abe6adc1d2">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a68a3c39-d185-40b1-ba17-52223d584926">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3bdcc4b9-246a-426f-8836-0dd00ba305d4">EV <link linkend="DCM_122429" xrefstyle="select: nopage">(122429, DCM, "Volume Method")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4e5db8f5-1d61-4645-beaf-cccd7fd87915">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ceda46b3-dfaf-416b-bd9b-538c5469d462">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad5f539e-01c7-40b4-9089-c6e95d523544"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3be6019-7ac3-4955-9ec5-05232e03500e">D<xref linkend="sect_CID_3453" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0c8aa703-333f-4294-a0cb-4c3e3209fb2e">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e52f7afb-0633-4ddc-93a9-67896c76d0c6">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cdc6bc01-1bc6-496d-ad78-1be3121d3c4d">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_77bf5060-7ae0-41e8-8718-43d8df90a58f">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_150276c8-2802-4eec-90eb-8b6579f8d285">EV <link linkend="DCM_122435" xrefstyle="select: nopage">(122435, DCM, "Regression Volume Exponent")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6034ba78-aefe-4f71-8370-79798c60e364">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_03c896bb-f8fb-450d-adb7-77b6fb0a883f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e078dc5-8215-49c1-96af-5c0d2d679a4b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4e2b706-bc83-4c95-8e4f-0bb9e000e10d">Unit = DT (1, UCUM, "no units")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_867493f8-92fb-4557-9ff3-cacf34d8b844">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ef2f8b7-5756-4c3b-ac64-ee28091e6641">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f0dcf12-b266-463e-94d2-f7dfca1284bc">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a8063cc-ab87-4051-a083-a367a04aed7d">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7352895-8cf8-48d1-94a2-491e3076449e">EV <link linkend="DCM_122431" xrefstyle="select: nopage">(122431, DCM, "Regression Slope ED")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5bb1904e-9651-4f5c-bf71-0692e7f23550">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c5539537-e56e-46ec-a7e9-942c3c6024d3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_efba029c-d42b-4d75-96a3-a41a3f3c3974"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81ec6e55-698d-432f-9075-3fd11bcd1866">Unit = DT ({ratio}, UCUM, "ratio")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70283aba-a7e8-46ad-afba-18e0cc01cc45">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c49a198e-5c59-4767-bcaf-f9b45eca5f05">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc7728cd-d013-4609-9c2a-c296b475ed43">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_653a92e2-baff-402d-8ea4-3269ddf27221">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_442ea27c-3764-4818-9f09-20b361213e73">EV <link linkend="DCM_122432" xrefstyle="select: nopage">(122432, DCM, "Regression Offset ED")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_77c8fac1-c907-47a7-b9af-ea33d4f42356">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_55f55cff-82c7-4c1e-a6d9-37fac6ef0776">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e1510775-a739-43da-9c0c-8f5be111735e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8ae6625-a62b-413f-9fb8-075b0d2d3279">Unit = DT (ml, UCUM, "ml")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d2e6d66-6085-47e9-b31c-06b0e94d6616">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31632e94-6828-4ab9-ba4f-713b2c27a575">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a8d1cbb-3c7b-4aa8-b16d-4e3138d09bd4">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02475f6f-6229-4741-9fe6-7aaf9987b754">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37d5803a-3f00-4840-9bd0-549cbc1a092e">EV <link linkend="DCM_122433" xrefstyle="select: nopage">(122433, DCM, "Regression Slope ES")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7f6fa057-c962-41f0-8ab7-682ae49de333">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f9a183d-700d-4c53-b34e-ad1c5ec0abc7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_28cac620-35b7-46c8-add1-12095adbb75a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7aef8523-4b71-4bdb-a4f1-83d0f31eb148">Unit = DT ({ratio}, UCUM, "ratio")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef8c36cf-2975-48f7-84d8-ba3f994f0452">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f6921a1-b98c-4662-a10d-e29aca8621a8">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21aeeef6-41fa-4eea-b069-5ad733d47913">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f491f5b-6f0e-47cc-a00f-fcd7dbf37e21">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3578735-6da7-4bb8-a489-144b05616d35">EV <link linkend="DCM_122434" xrefstyle="select: nopage">(122434, DCM, "Regression Offset ES")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_849d7a94-9891-4d65-86d7-adc1bfa89b25">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e0c77304-29fb-4e4e-a1a7-10056e794556">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_175589ec-b1ca-404d-a00e-9b16808dc581"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fcdb4198-d10c-41a4-9a59-327b180b9bb4">Unit = DT (ml, UCUM, "ml")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_339c9e5a-eebe-4c16-8db3-daf70ff408f8">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bda89d84-df4f-49cc-8413-dfb1a743bc47">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b759ab6c-f7a2-4e2e-8082-abe29233fc3d">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3cd25335-7ec0-4064-857b-0687cd57224a">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d7da3675-1861-459f-b794-58a97cd0422f">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fee44f3b-03eb-4722-bf1f-70f2cd9f9acf">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_34d55be3-2ec0-4dd7-b488-f7982a43bfb2">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd154215-cf2d-4964-ad5a-35ee12fd0a93"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c9a4343e-5c19-4b13-af1c-3ad6847dd706">$Measurement = D<xref linkend="sect_CID_3468" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_c0ac38b4-0ccd-4db0-b60d-9c60287dc159">$Units = DT (ml, UCUM, "ml")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_18153b17-e81b-493d-9ae2-e306674be1e7">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8164a94-5c25-45cc-86ca-286c42aff451">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62df1290-34e7-48ff-aea1-ae2d97644730">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0207102-bca9-4c18-a420-1e996c89684d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0291e495-a174-418c-b825-e99b16ad1ba1">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_90282c31-dec1-43e4-b6c9-bed9d096a368">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e07d1a5b-d5a7-4e7e-9f3d-a7ccfd76bee8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30b4732e-b6c2-4334-873d-7482b58cad8b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80ea2665-1c17-4c23-a9f7-12711d74f977">$Measurement = D<xref linkend="sect_CID_3469" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_a57c0213-5425-48f8-bdc1-97cf46060f1b">$Units = DT (ml, UCUM, "ml")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f1168d6-1061-4dc1-b7a1-ea417c5c8ebf">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_736c9ef7-fbb3-4fc4-a35b-6dfa40ad9126">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1dc5d59e-4106-4a3f-b7bd-f752b2c463b0">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5cf6b371-ba9b-4bdc-91a1-db803d0199a1">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ceaaf31f-dcec-43b7-bbb9-11581278dd67"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3acc5f8a-b6d4-44f1-b00a-0115677a4d80">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d7742c0-29fe-4ad3-a21b-9e818d283a69">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35d3a4dd-895b-42ac-8f9d-4ceefe19c8c9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_acc88fa2-42cb-4360-ae3d-8a33432f4aa2"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_b83eb0c0-c9c6-46e0-b465-959f51186366">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_530bb1a2-5780-4fc1-a4cf-ce9094725b90">Row 11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a9f2f56-830e-40c3-a56b-aa439737eff6">Secondary Capture image with ED and/or ES contours. No purpose of reference is specified.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3208" status="3" xml:id="sect_TID_3208">
                <title>Frame-to-Frame Results</title>
                <para xml:id="para_45a064e1-78ec-4292-b363-fd70efe4a6fb">The Frame-to-Frame Result Template consists of a CONTAINER providing measurements derived from the angiographic images on frame-by-frame basis.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4fa41383-dbef-4a4a-9ed7-cc567b3332ed">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_c111d000-e8eb-479d-a8e8-71f7f231f731">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_500dab6d-5c61-49b4-bdc8-57679730160c">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3208" rules="all" xml:id="table_TID_3208">
                    <caption>Frame-To-Frame Result</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1e5fe763-7143-44e1-8817-c7e64143ef16"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1414ce5f-06a2-42d9-9903-45d1aaa6c215">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_66f340f0-f362-4d56-8e94-a39c29f1f881">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ba821e5b-6890-41ab-976b-53ebf2f36179">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_99f91c46-e0e8-410d-a259-6e45a7df3c7a">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1196b3b6-7505-4ecc-b999-3be18f3782a1">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3fa87d73-5c77-4a14-8fb2-2144157a9a9b">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_05a3df68-3dc3-4d37-a8fd-b9130b63a87c">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_12905583-e965-47dc-8549-078e2ade8bc9">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72b1bea8-35a9-4921-a45e-88008a198c46">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_869570e0-b5e9-428b-a807-466a706ca1d4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b591c59-8621-429f-af81-5fa355173baa"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9201043-c598-49dc-a6d6-3dc96043b0ae">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ded4b313-466d-44c4-b226-0fa59c082641">EV <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_124c1aca-f29d-4f61-9275-a4610075494f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_03bbd7cc-b4c2-4a9a-82d8-b6647ff8dbbc">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ed017f9-b6da-4d22-ac73-6cca050334ba"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3cf9e65a-05d1-4426-ab69-6666d24ba777"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48e2275d-3b21-4b09-976a-502cf56bb3bc">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b694c353-2915-440c-a31e-8e0844e3a853">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_801c6092-611e-4940-90aa-fbedaea189b2">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58b43882-e32b-4c3d-926a-c6e9a76e6afb">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73d6f9ad-a8c5-4f85-9510-4dbc010355c2">EV <link linkend="DCM_111004" xrefstyle="select: nopage">(111004, DCM, "Analysis Performed")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_81ace731-d1d5-455e-bba8-fe76a9356a69">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a0dfb69-bdef-4fde-ab0e-e5b4bfb31f93">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af7d6184-58cf-4884-bcc5-dcea26344d4d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35a66914-d28d-4d52-8fed-f2e4c12e9f62">EV <link linkend="DCM_122499" xrefstyle="select: nopage">(122499, DCM, "Frame to Frame Analysis")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_216ff3bc-14b8-4938-9224-1a0e69534dab">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a612d79a-77f9-4ef3-8818-2ff7140028c7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb58ce9c-aaca-4991-9a37-5e862d023942">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6926ca5f-e7a1-433a-a136-95b4af3ad842">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a198e5a4-963a-4c1e-bb05-a70515b8d9e7">EV <link linkend="DCM_121112" xrefstyle="select: nopage">(121112, DCM, "Source of Measurement")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f378ce46-1892-4b4b-b1a4-589ad0c43dfc">1-2</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2f11bd2e-1f11-4289-9eba-5241ab29ed63">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5f0c5ad-efb0-4211-9bcb-9a1e63a29482">VM = 1: Single plane analysis, VM = 2: Biplane analysis</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1675b4b-d714-43fc-a328-a5b6575caf3d"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2d29e47c-245c-42a0-84b2-45ead0f4bac3">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6aff4ae8-f324-4532-9bbe-be7a009ac559">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f049f763-e16c-4d75-ac3f-9d73127eda87">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b7ec237-30df-417e-b452-3dc040b726a5">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc109f5d-0ff6-4c09-a4e6-5bc57e72f08a">EV <link linkend="DCM_122429" xrefstyle="select: nopage">(122429, DCM, "Volume Method")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_42b6a2a8-b68e-44a6-9c5f-7460463b9be6">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d0a2f6eb-f2be-4d44-b6da-e9fa6fb075bb">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1f963ee7-e0b8-4ad2-87a7-3de061a13ba1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_53788863-1062-424b-b04e-94a951ee4a61">D<xref linkend="sect_CID_3453" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92b6f10d-bc82-428e-969d-7114cc46f8a0">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13c27bbf-2932-4d92-8912-0cb3f1fa0362">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea278bb1-291b-46d3-9f32-c9ea23a1d7b4">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc812d09-7600-477c-9de5-a555b7062182">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d9719bf-4d34-4566-bdd3-53912c714feb">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3921ec6d-09bf-43bd-ace0-581e81eb6b80">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69d9fc25-8699-4a62-ac8a-c67889961ebf">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1dad230f-6000-4aeb-9c6a-c2f919a72524"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7299c9f-fc77-4e51-9497-17e767e493a8">$Measurement = D<xref linkend="sect_CID_3471" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_67600ec7-7dd1-4699-a0ec-06801174ba45">$TargetSite = D<xref linkend="sect_CID_3462" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_29f95e8d-2866-44d6-9b07-be8c727e112d">$Units = DT (ml, UCUM, "ml")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_254e339e-f158-4619-a283-fdd48439beb4">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f41d4b1-7392-4dba-81af-9c2d4eed2e18">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a5c8b95-a840-4d91-bb97-5533cb341fb8">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43234e67-910e-4635-a0b2-8fd0b9d3c631">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_56923d50-b795-418c-b3f3-bc318257c53c">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8e32c27d-848c-4f48-81e3-86ac0a337fc7">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e1a54e4a-b3a7-457c-afc8-1057ce6655e3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f1561ea-a22f-4e47-be20-92bec8596d5a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3754cf50-0435-4430-8b88-48f3adfa34ae">$Measurement = EV <link linkend="DCM_122445" xrefstyle="select: nopage">(122445, DCM, "Wall Thickness")</link>
                                </para>
                                <para xml:id="para_e31d1f3d-9738-4849-af70-3ea651ec07b2">$Units = DT (mm, UCUM, "mm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8e1fe42-6d35-4460-a661-2d532e296a72">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99f5de7d-bab4-42bf-a937-91581dd6ff75">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_932863d7-5865-4971-9265-2be94df074cc">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b1b3ab6-f5b7-40f8-a8f0-ab90de476556">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83ea3881-f394-4b69-a901-ba93b1a3cb48"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3d04ab83-6937-4749-90bc-76687b79d81a">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a4f92f49-179c-4aa3-9900-7de70fe6fa9d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09ca9d31-98c8-41ec-893d-bbd3a1c7af0d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16c7316f-b1ab-419e-99f5-980d5648ce76"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_9b488e8c-bea2-4162-8be3-d4031c93a0da">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_34713560-65a2-4535-8f6f-2bc6cf1dda5d">Row 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d5314b4-9f2b-44db-8bf4-165a78271468">Identifies each frame analyzed, using the multi-valued Referenced Frame Number (0008,1160) Attribute of the IMAGE Content Item.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f727ded8-e935-48c5-b409-98804d0ec85b">Rows 5, 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c3fd8b47-a8fc-4e3c-8484-5c229c0b90cc">Includes one measurement for each frame referenced in Row 3.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a722a101-874a-41fb-b697-a6b35cc68f50">Row 7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a319bf79-77f3-472a-b49f-c65d38ae9ad5">Secondary Capture image with ventricular contours. No purpose of reference is specified.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3209" status="3" xml:id="sect_TID_3209">
                <title>Centerline Wall Motion</title>
                <para xml:id="para_bcb49358-d755-49f6-93f6-e6956bdde5da">The Centerline Wall Motion Template consists of a CONTAINER providing measurements of the centerline wall motion.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_069f5c9f-9ba2-4191-9bff-b36d8d48c512">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_a034d901-ed25-4dba-a7b5-c990368347e9">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_e8ba050d-1527-49cb-aa53-3f08259726ae">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3209" rules="all" xml:id="table_TID_3209">
                    <caption>Centerline Wall Motion</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f37a90de-0612-481f-8be3-2e419721bf6a"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_570187ba-c8c6-48c6-8dfe-d8952471c44a">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_98356399-8554-4ffc-840a-74eee213d356">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4cd829d0-f891-45e8-9cb6-f5b2b0cca3ae">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_18384740-ecf0-4408-adf2-c1749dd4a639">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d57f3def-a942-4cc9-ab84-b1616968f344">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_50b6bc66-10f0-4327-8002-744fa52950c2">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1a0ed6b2-c0a2-4d83-9869-719b1d698a13">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2b38a2c4-c597-4b3f-a43f-7c6493e1da80">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b827425-13cc-4087-b007-56b09f50fc20">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d968aace-d1ee-499e-bce6-7fe5decb69aa"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31a88972-9127-40b6-b3c9-0a635bfc0b64"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2e005ad-3c6c-4107-827c-5f7a3ba79201">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6c38e4f-dcf4-4d1b-b126-083761323aed">EV <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_429c0ca8-d3ba-4698-929d-658064cfc909">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2a379bac-46ea-4036-a0e3-1a13bf713475">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e7dcf6f-da1c-4325-abfc-6daeae0839d4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c92ad17-55d5-472d-b5ef-bd5a34974260"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eaa4822f-a1b9-4ad7-a320-203454739255">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a215f58-fb93-4337-a367-9ad197cde34f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9214086f-e913-4cfd-8a5f-c70e26bcb442">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_15d2fdeb-106a-496a-95a8-0639a9bc3176">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8cad908e-2c96-496a-99ed-d355e68a8b25">EV <link linkend="DCM_111004" xrefstyle="select: nopage">(111004, DCM, "Analysis Performed")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aafb4eef-e517-47d8-8b7f-7ca16a080bf3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b0094123-b981-4b6d-9d82-a129c9370e2d">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_77c38bc2-858d-4408-8771-be3c10ae3199"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_faa68f22-75ce-4f49-a3f9-fb586fc42692">EV <link linkend="DCM_122449" xrefstyle="select: nopage">(122449, DCM, "Centerline Wall Motion Analysis")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef4f38a2-0d51-4610-9fd8-0246b6a07c88">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c6940bd-a092-4396-845d-eaf43bf0dabc">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f4fb2aa-3d21-443f-a330-d8ad57efdf89">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7845203d-5284-4f57-a77d-0fbaf26f1d21">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4be7b679-f1b8-4c09-ba66-e3ec72f15806">EV <link linkend="DCM_122410" xrefstyle="select: nopage">(122410, DCM, "Contour Realignment")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cb621e95-502c-4a7d-8d75-a1f77db418dd">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5cebbbab-6636-429e-998c-966ee3e77f79">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9f5151d-c537-44a9-b977-d8a0760855aa"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7049323d-6d50-46f6-bc17-a5c3867008c9">D<xref linkend="sect_CID_3458" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a98634b-3b22-4117-9f5c-02f0f44a2faa">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ea2bfce-65cb-4654-8786-35f5ea0ae889">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_171bab0c-6bd2-4040-95c2-ddb3060a3d30">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_edd34c31-3978-40ed-96b6-8e793663b6c1">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c69339f6-922d-4b97-b0f0-d1a40ca418c6">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_907794cf-936b-4fc7-b810-ca7720d93662">100</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_defd3552-2ac9-4272-8ad9-e97e2035f2f0">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5f1fe5b-587b-483d-a651-bde1dc8e7243"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5878fc02-6d68-410d-91bd-f9392723545a">$Measurement = EV <link linkend="DCM_122450" xrefstyle="select: nopage">(122450, DCM, "Normalized Chord Length")</link>
                                </para>
                                <para xml:id="para_157f2da1-14d2-49d3-a1b4-acb3181f0285">$Units = DT (%, UCUM, "%")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6f831cb-1431-47ee-8863-46638af7be9e">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d440e81-7adb-4bcd-ab17-07df77226a04">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2bc0474-2888-4f7e-8d71-4871795ce2bf">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54b4a8c0-4596-4b6c-b610-289db5b8666a">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_535def70-702d-4e49-b68d-02ae22a3edae">EV <link linkend="DCM_122411" xrefstyle="select: nopage">(122411, DCM, "Threshold Value")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cce1aee5-416a-4e30-8d62-075b6da8e864">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8903dfbb-e85b-4dcd-a14d-81d46fac9d85">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df7976f2-1d7a-4e72-a626-e4bb07235042"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c907b1bd-67a0-45ca-9239-105881967466">Values shall be 1, 2 or 3</para>
                                <para xml:id="para_ad35d22f-56d8-497e-86ba-fc3a88650ac7">UNITS = EV ({sd}, UCUM, "Standard Deviations")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d9eb3e7-fa94-498f-8ce9-1f50eca1b4a1">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a849a80-65e1-499c-a894-f557d8695bd3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1eda06b3-95bc-4678-9645-d260bcb8f561">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ca9495c-d473-4ad4-a743-e601c03f54ea">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc0c76c8-b10f-4070-a986-c280cb24c375">EV <link linkend="DCM_122451" xrefstyle="select: nopage">(122451, DCM, "Abnormal Region")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_33355622-95b4-4b9d-ae22-305340481efd">1-6</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0db0d731-b499-4e1a-86e3-4162645745a2">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f6964cf-4b19-4b7c-a4da-16d963169994"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c7a82b1-e231-448b-8eb8-b8ebdca0e7cd"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8b4919f-883c-4e94-845f-0d17bd0bf301">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd54d5d5-7df3-471e-be18-fa3e32732f5a">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fadb768d-a50f-4904-b5dc-61c3535a4f2f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35e16698-df08-4a5d-8f25-410e81072e15">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_41097498-c07b-4c1c-aece-372dcdf0022e">EV <link xl:href="http://snomed.info/id/60797005" xl:show="new">(60797005, SCT, "Cardiac Wall Motion")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_655ea786-b058-489e-a21a-1973ce003bf9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_56fc7dfb-68c7-4978-8d2d-7885a482fd10">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9798b609-0e6c-4a7e-adbb-0e776ce28ef1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8f3f208-3058-4a20-a3ff-9da36ef83d57">D<xref linkend="sect_CID_3703" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c3d4f17a-f2f6-465c-bd83-2d35494af7f2">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c2cc3d35-531c-4c15-9d80-2d2e0f2b2d25">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bbcfe938-e7fe-4387-abad-afa3c16b8db4">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c83b25c-c861-4f21-b995-8d51b6b34871">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9438bb7-8a14-4f04-b876-8909433bc533">EV <link xl:href="http://snomed.info/id/255593009" xl:show="new">(255593009, SCT, "Circumferential Extent")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3925ef95-99c7-43ef-a3d2-7117b7033163">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b8ae3157-3413-4b2e-90b9-411fd7be4810">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5dcbb783-dc36-40a3-bc7e-681eb9790d75"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fee80167-7324-457b-b598-53c25c1d06d1">D<xref linkend="sect_CID_3460" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f57a40b-28f7-4418-b9b0-d5c3eb06c0b9">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_504c5591-7151-49f2-9d0d-1ac1def9c92f">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd744254-058d-4825-a2f1-d0524bb6d9ea">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_251fc09b-21fe-41c7-9158-ff59bd777df1">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa4c0cfa-cbeb-4295-accb-7c60c1d231e6">EV <link linkend="DCM_122452" xrefstyle="select: nopage">(122452, DCM, "First Chord of Abnormal Region")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_93286af1-62b2-40be-b674-6f54715a10a3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c2d3391-d7c4-486d-8628-8ff3ab76b7a9">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_735e0a6c-34e8-479a-b19c-e7b4fa509ba0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f5a962c-b7ac-4c9e-902b-20e2604cb528">Unit = DT (1, UCUM, "no units")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a58bb33c-0360-4e3d-a216-7a2d7198d581">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_18f2c4ad-c64e-42d3-8ed0-d0a76d781af0">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c9ade54-19c2-4db4-8957-cb4914acb5de">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6eaa86db-511a-4191-a7f4-2c5d5879eb9b">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fdb76207-0372-413c-b0b2-392c01d26c16">EV <link linkend="DCM_122453" xrefstyle="select: nopage">(122453, DCM, "Last Chord of Abnormal Region")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ad9d778f-63fa-4ca0-a7f3-4701b14195e2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7c91bab5-3c3c-4468-be73-5691b25c6c49">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42857310-d516-4f33-9d76-3f3903a31bc2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84ed0c75-0d28-4487-a8d2-505c904a5d67">Unit = DT (1, UCUM, "no units")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54c4d663-5c55-4d19-a934-f21b0cb71e2d">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5d8eff7-8d39-4441-af3a-8bc4c3ed7b84">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a5a9608-22e3-4236-850c-b77ac2382a87">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b353bfd-9bcb-429d-a317-e243299272ec">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d6dcff0-6ca8-4070-9044-1a3641e5e2de">EV <link linkend="DCM_122417" xrefstyle="select: nopage">(122417, DCM, "Regional Abnormal Wall Motion")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9721cff5-cc07-4d70-9cb3-87bd7e622c15">1-4</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_122bcdc4-2966-4f1d-a026-0d1ca33ebf6d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f8c9ca7-59a0-490d-a387-ddc1df652f1d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f913775d-721e-4761-8b7a-bb8c81ebab41"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_60e89cce-f9e3-4f6a-81a8-6c0163b58931">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38fbd8b8-b549-4967-abc3-4b7e01dd02ef">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d576a21e-6a04-48de-bc36-6061b7a79f97">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a00438c1-52ab-4f11-b59b-07d26e1c893b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_181558ce-f4c0-4a6c-8ebb-6f44ff9abaaa">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf33d973-234d-42cc-bf6f-985a79c93872">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f9ad221b-2ca6-46d6-8344-82e8fdb9ae40">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bbcc8127-5525-4b18-a194-c754a6a11746"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2a45c27-982b-451c-8ade-befda08ad25b">D<xref linkend="sect_CID_3461" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca823e1b-baef-47c6-b9b1-653f3e2c2a0a">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d4dd96bf-eeb5-498f-91cf-85eb63ad135a">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0df0897-cbfc-477e-bd09-dab86fe61dc1">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_899f0803-6172-4479-85c7-7810d5deacf7">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11c1e408-b8ce-4fa0-ad2a-4782d0eb572c">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_97b8a06c-0f3b-42e6-a44d-538ecc379eec">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3cb534ea-e31e-43b4-8532-628d669dc9e0">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9e600d8-03ed-4d98-829c-562986aeb03c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9009730-074c-4fee-89ca-8525d9071215">$Measurement = EV <link linkend="DCM_122459" xrefstyle="select: nopage">(122459, DCM, "Territory Region Severity")</link>
                                </para>
                                <para xml:id="para_c84f3bf0-e2e5-4bda-a09a-e27fe0feb094">$ModType = EV <link xl:href="http://snomed.info/id/60797005" xl:show="new">(60797005, SCT, "Cardiac Wall Motion")</link>
                                </para>
                                <para xml:id="para_72833ae7-3638-4bb8-8990-42d0d88bf020">$ModValue = D<xref linkend="sect_CID_3703" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_d994276a-a02a-4ddb-92d0-de8133f6d1a3">$Units = DT ({sd}, UCUM, "Standard Deviations")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43d9beba-eebf-4604-8d8c-f647e8a69d01">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eebdd34e-49ee-4351-8c26-3c26b29b1ff6">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2aa098ab-a8c1-4405-a410-3d3ef12e1ee5">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3436db96-f3ac-4b2b-afb5-bf62cbb23efd">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_12ebcf0c-6a0d-4732-92bd-f96f1cc4e8a3">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bbee8f0c-c8ca-40e9-b096-889c26ec7f53">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8a581b34-924f-496a-9c5a-6b7b76e28de3">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fbd6b99b-e3c1-445f-9f6f-facc125b38dc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c3f42a93-51cb-452b-909e-a4f7c0f340f8">$Measurement = EV <link linkend="DCM_122461" xrefstyle="select: nopage">(122461, DCM, "Opposite Region Severity")</link>
                                </para>
                                <para xml:id="para_2264212f-1c6f-4d65-9750-19b361c49a09">$ModType = EV <link xl:href="http://snomed.info/id/60797005" xl:show="new">(60797005, SCT, "Cardiac Wall Motion")</link>
                                </para>
                                <para xml:id="para_87e71df5-80bd-4e32-a8dc-da3984a5c789">$ModValue = D<xref linkend="sect_CID_3703" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_168528c7-733e-4d4e-84ba-59b8d89a50af">$Units = DT ({sd}, UCUM, "Standard Deviations")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa61677a-5658-4177-8c32-d278ad686f41">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d64d3dd9-5396-4e66-b7b8-5932e11cd7f7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9488bc0a-87c9-4b29-b1b8-cea27a5872ef">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4eb87d4d-793e-412a-bce2-6ca6215b509d">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_56d4bb9b-0e6b-4715-816a-0dfadb4b548f"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4b09cd87-3b1a-47d8-9763-834e807a4ff6">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d33cb1e2-7b41-423d-a0ec-227b9c522da5">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5fdc62a6-e57c-42da-b829-c0d32db956d9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_213af6da-65b9-4c2d-9bff-c0cade7376fa"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_a4218650-dfec-4335-ace3-fa6f46c005ed">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cee74b93-ddf1-4f7e-9896-168178a93219">Row 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e94d9730-ca35-4a8d-a149-f69f37dd97c1">Normalized lengths of the chords determined between ED and ES contour. The measurement Template allows the specification of the statistical properties of the normal population and of the chord measurement relative to the population.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0202ea9a-f348-4b8a-b8b9-ae119eba8ab4">Row 8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_314f5c4d-deff-45dd-9956-087ae03d577d">If the Circumferential Extent is not specified no limitations to the boundaries for regions are assumed.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a90953fc-4a14-43f4-9001-cc4317255b7d">Row 11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6509c72d-3fbe-49b5-b1bc-ee53be166041">The Regional Abnormal Wall Motion container holds the information on the severity of the decreased or increased wall motion of the 4 predefined regions as described in [Sheehan, 1986].</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1aefc978-3c2c-4de3-b3d8-91718125a38b">Row 12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da4d0e56-3b47-4f88-90f0-c37b264af1b0">The name of the region with an abnormal ventricular wall motion as described in [Sheehan, 1986].</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62e75a01-f826-48c7-b004-96f341ac848d">Row 13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c8d1a5a-0264-4191-a252-ad6440b68b5e">The severity of the wall motion abnormality expressed in Standard Deviations above or below normal in the territory region as described in [Sheehan, 1986].</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b033cb0-8516-47b1-a3c5-e0ad88d9421d">Row 14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_90801748-0c5b-4e90-aa01-2a72c298c47c">The severity of the wall motion abnormality expressed in Standard Deviations above or below normal in the opposite region as described in [Sheehan, 1986].</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a1ba4dc-ec0e-4299-a755-d9d82cbed7c8">Row 15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_766738b5-ec6f-4d35-ba02-3245a698e39a">Secondary Capture image with centerline analysis result. No purpose of reference is specified.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3210" status="3" xml:id="sect_TID_3210">
                <title>Radial Based Wall Motion</title>
                <para xml:id="para_24e9f317-12e6-4737-9be2-d180aa9023d5">The Radial Based Wall Motion Template consists of a CONTAINER providing measurements of the radial based wall motion.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_85d82ea1-58de-467d-861f-6aaad32806ce">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_558fa6bc-79b1-483d-991f-2640477ba438">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_5a5e33c6-c730-4a30-8b84-899205e8a87b">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3210" rules="all" xml:id="table_TID_3210">
                    <caption>Radial Based Wall Motion</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7f7b3eb7-e28c-4910-9921-803b0f0024bf"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_afde637f-8397-4e18-ae31-a01479b7287a">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_516a9e7c-ab93-4273-8dbd-4db9337d1b7d">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_297bb821-ea9d-4ab1-ac61-335b7768d129">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_185722b6-c22d-49d8-9d3c-13b17e457536">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7772170b-c8f6-43aa-a11d-30bd1ea576ec">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e1d5c6ef-9ac3-494e-b91a-35f0a097e535">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_868f48f4-049c-49ca-8674-0c7290667cf2">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_86d52ebb-ff45-4de2-94b6-4d4d4b19df24">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c816e954-a031-4d97-ab38-a183fe08c500">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c69e3f9-2d06-421a-b29c-ad9a1cf62de4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_511cac1a-6584-470e-a23d-143d65b1f34f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae6a424d-0389-4258-b270-04679929abb7">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_682507e4-61ba-4e42-a18a-4ac1a11d8532">EV <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69f79a75-50ed-4e55-87a6-5593fbc241df">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a73f9290-9935-45cc-946b-633266f2e887">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7116c16-9e8f-4b1d-9c78-901209d44ebe"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b0ed858-2329-4ff9-97e6-36579845009d"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b9b8862e-c9b0-41b1-aa93-17ff2b461bae">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d08018d6-525d-4b32-bdcb-25c82a0f4dcf">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7945fee-9286-457e-9cb5-150109ba9a82">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c6b2ce6-a46c-499d-9ca4-dd2853d19181">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e09e4a7-7fda-4f46-a539-ccc17de53f27">EV <link linkend="DCM_111004" xrefstyle="select: nopage">(111004, DCM, "Analysis Performed")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b06de381-97b2-471f-8ce0-19074a953204">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eeed3c74-dd11-4b3f-b0e5-04187957e015">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69ff0608-1d60-498d-b745-50ff1c2458b1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3242b73-4b72-4f9e-96ce-12c1c11d712a">EV <link linkend="DCM_122493" xrefstyle="select: nopage">(122493, DCM, "Radial Based Wall Motion Analysis")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c78929d3-0ab1-4e04-9d5f-2ffe8f2eef0e">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_18cdea6a-554a-473f-811e-a32c82135bce">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da508fa7-5140-4219-8355-0ad8a4a992bf">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04171a38-78e9-4330-86d8-e0bf12a0a9da">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_18c84764-2981-48b7-9134-4a328e04dcc1">EV <link linkend="DCM_122410" xrefstyle="select: nopage">(122410, DCM, "Contour Realignment")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a70a50bf-0d9b-449b-9120-bcc23ebff793">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dc4f4d5c-d723-4f80-86ef-47a07c8d2279">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a1dfb71-fee0-4918-91e9-b645561788a8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58e3a612-890a-41a5-86d2-6b745bf60784">D<xref linkend="sect_CID_3458" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_23fae1f8-d86b-4148-a568-835766b12728">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0895105-a04e-44e9-8d62-23cba4d5bd51">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bbe25004-b849-4909-8d7b-5844462ed428">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed4c9a7a-7f75-4d28-baf3-c48874bfa7df">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3040c9b1-7e7f-4735-867f-aaf92958de13">EV <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7b9716b-c2d4-45a6-9691-45b690f86907">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_accb4c2b-ae62-4109-bb50-6174586c359b">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a40735d-92e2-477a-8aa1-ac4fc08c43d4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb2edd52-9098-4280-a9a8-3a90caec26e0"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_53981928-dbe8-4b94-8942-5e2a32570557">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_afa5f8bf-8e93-46ae-9b97-ff14ed92feb8">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36b80c3f-c6d3-45fa-b85c-8fa5205324c3">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05f22f06-1e40-4c7d-b8f3-4cab77d30d13">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eabe3dc8-d603-4236-9373-419e7218e13e">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5494306a-e997-4503-bf05-f383654a54c0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_53325cab-444b-4f65-87c6-602f88150a40">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe77e9dd-e578-4068-8e77-41a306f51de1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83f70ce1-06b2-46ad-b825-3eb85d2dfc39">D<xref linkend="sect_CID_3718" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eac05f3b-b7ce-4af6-8183-c12e99d7953a">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1f515ee-f4fa-4462-9c53-0d6bf58b2e19">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d508176-4823-4577-8582-a976d71e823b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fab4a458-6a04-467e-91b4-cee821b04a0f">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7da27f66-1871-48ef-bd11-c9ac4521049a">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_422d1d43-ce41-4446-9bf6-95a58a18d021">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_278a88c3-bedd-4f93-9e1c-3d37e16ad014">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51f7c606-dc6f-46ba-bc4d-5da06ae168aa"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a88a96d-4e4f-48ec-a5fb-81cc7f725f6b">$Measurement = EV <link linkend="DCM_122495" xrefstyle="select: nopage">(122495, DCM, "Regional Contribution to Ejection Fraction")</link>
                                </para>
                                <para xml:id="para_6c5504c8-1903-473c-9f0c-3d97c43b86f7">$Units = DT (%, UCUM, "%")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9881ea15-5c56-40e7-82ed-2bfc0e89891d">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9092f21d-7b5f-426d-872d-3d72b18f8134">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5dbda5e-7444-45b6-ae2c-a33622e23df8">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d375c6c-6c5d-455f-88c1-5573b2aacb6d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f58fdf3-2ea4-418e-9d23-e9a956abe6d4">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_929ca00e-e634-4bc8-9790-e3c7467a3c4c">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_28fe7e08-1ba8-4bcf-8500-c684f1d660c2">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38918e35-2c55-482f-ab37-1ad96465c98e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee8b215a-c7bc-473a-82a5-5750827208c9">$Measurement = EV <link linkend="DCM_122496" xrefstyle="select: nopage">(122496, DCM, "Radial Shortening")</link>
                                </para>
                                <para xml:id="para_0346750d-21db-4eb1-b238-bb3029211b39">$Units = DT (%, UCUM, "%")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_621fcee0-57e3-4aa3-87b5-7e21c686fa9f">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ddb1752-0c06-4901-bd23-c7e7a22eed7c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9f774d3-561a-4751-a509-00c62aad7e75">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f7c24c7-1542-44bf-b98f-85b209bc86ab">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35131e55-4724-42bc-b6d3-54155aa37cf9"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a60a3780-cda2-49f0-8356-a460d0ab1d1d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_784faaee-7445-47e7-84d3-9646ab679763">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0fb7d42-b95c-4839-8f25-91f79a9c0d60"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83beacb6-8437-49c6-8e0e-e05d6362c65e"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_574f1eb6-caac-40f6-a59d-46efbcef0304">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_100b73a5-a320-436d-8d5b-b0f63c483e8c">Row 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da3e2b26-29f1-435a-ac31-0effb870eb4e">The CREF values of the 6 regions determined for the radial based wall motion</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a37e45bc-062e-4acc-acb4-87883b563020">Row 7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f1e0914-a14a-4937-a275-7ae2f20e6cd3">The shortening of the measured radials within the region</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f70b3bb-68ea-4f14-81ce-e08378431ef4">Row 8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55145091-7962-4a25-a9b7-03366139eb13">Secondary Capture image with radial based analysis result. No purpose of reference is specified.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3211" status="3" xml:id="sect_TID_3211">
                <title>Landmark Based Wall Motion</title>
                <para xml:id="para_45901ed9-79f0-49f6-8da4-0110e9f933e2">The Landmark Based Wall Motion Template consists of a CONTAINER providing measurements of the landmark based wall motion.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_a00aad7f-ea87-4714-b2a8-a1b581ed15fd">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4ead7fe2-354a-4dd9-9e6a-1c0469518519">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_986ffef9-d15a-40ad-97d6-b9cc5b3a8b64">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3211" rules="all" xml:id="table_TID_3211">
                    <caption>Landmark Based Wall Motion</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_506828e3-f2a5-4703-92a0-af7c78d6c7d7"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_006e0475-6de7-476c-963a-ef0a49a9267b">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_71ea75ab-aab7-4834-a10a-da48bbb90703">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_27f3b5a1-ee06-454d-aed0-282587024aa7">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_07d655d2-b1de-423e-b1ad-4a50b24a085a">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2897b894-5e1e-47d3-b579-f433ee28be78">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0c883d50-2353-4365-852c-5ddac42a8997">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a4eeb364-6562-4129-a1ae-72570610cc9e">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_43610c1e-7292-4eb2-b224-e094c5bc4249">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c2977ad-2e36-49cd-8fc4-cc14a18776f5">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2357f38e-b885-4503-b2d7-f958320c9854"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_111420fe-7371-4e62-9553-094886f37d95"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c79e8ac-b3c8-4118-8fb5-b7de64440edd">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3eb03d8-e510-4958-b052-bd6269779e95">EV <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_95cf5bcd-4460-4e2d-8922-8422ede3dec2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d4dde6b2-79fd-4d88-a6b2-4c0d98032bd1">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5fb4ecde-8b7d-4a37-9de1-ef94202f76c0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f26cd4a1-0cdd-4f36-9893-4f59122f9b6b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf7e18b5-0e4c-45bb-94fa-85f2325dda33">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_220716b9-aab6-438b-90a2-902ddc41c32b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fab301c9-16b3-44a5-ba68-5347da363708">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a916733e-de81-41ea-87c2-a8b87604320e">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6526306-7396-4d51-81c9-0ec3a3ef255d">EV <link linkend="DCM_111004" xrefstyle="select: nopage">(111004, DCM, "Analysis Performed")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_154b0185-6866-4d21-b91d-5e86cd1aff64">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f6b935e8-2ca8-436c-9f3a-a92d1c13d646">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0446d439-48f0-405e-acf4-3cf6ce731bf8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b9864e81-9e3d-44ca-917e-b40219782fcb">EV <link linkend="DCM_122497" xrefstyle="select: nopage">(122497, DCM, "Landmark Based Wall Motion Analysis")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_277fd710-c23d-40bc-8433-3cad5d0a9d08">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d488b058-00de-42e3-b714-4c18a183e447">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e397b37a-9262-4b6b-ac02-1a4fab297e9d">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e35807c-102b-41d0-8991-090fe72b3b9d">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1ed8e62-85e5-4328-a267-87bd07aad6b5">EV <link linkend="DCM_122410" xrefstyle="select: nopage">(122410, DCM, "Contour Realignment")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_848c198e-64b3-48d1-8a52-587a66627c36">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_58e536e5-4363-4144-85b0-01c82ca0aee0">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8371e57c-b412-4d6e-b8c3-6da1a5015151"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00e3c6da-7b37-4723-a8b9-f9b53ecc39e1">D<xref linkend="sect_CID_3458" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_530db3f1-f4eb-43cd-8226-95c63f55105d">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc9e3e32-cf65-4897-8c29-8632506dd801">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5bdd6502-786c-422a-aa5f-ed4efc308f2a">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_485c3c1b-dda6-409a-85fc-f81388017179">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04951765-73b0-4f7f-89e5-5198bd72435b">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_622b3aab-e573-4e05-a469-1d257723dac5">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ac21a9b4-8d77-4b3e-8dfc-f47881c8ff1f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_edab6a9f-d59c-4b04-bd5a-2ec0d6d8cf91"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f1cd6e4-6f29-4049-bf93-f6fc8f710115">$Measurement = EV <link linkend="DCM_122498" xrefstyle="select: nopage">(122498, DCM, "Slice Contribution to Ejection Fraction")</link>
                                </para>
                                <para xml:id="para_23c213ef-04f1-4101-a4e6-65cf2c608f01">$Units = DT (%, UCUM, "%")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88ff9cd6-7725-4b7b-ba62-c042e78e3020">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_56f36233-d410-4032-9b4a-413e2a5c3727">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b9a15cc-216e-4614-8448-3b8e8404655e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_32a762ae-281d-449a-8a45-190db2cdce4f">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10e92d2e-2d87-4d90-8ec1-0a047471d676">EV <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bde058ad-87a5-4bb2-9ce2-47b0797cf6eb">5</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_047aae4c-846e-42a6-9f85-74949fce5697">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae3a4657-d6db-4bcb-b16b-bef507c3554a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b47f952-992c-4bb5-8f71-a081fcb3b70f"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d63fdd7d-3b9f-4407-882f-f17da6e83d2c">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a2c3bcd-8ebd-413d-946c-400a12298eed">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8579de5b-63ba-4f52-8713-cbf3d7d9824c">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b6a8aac-3932-482f-b0be-6ff3d5ca34c2">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c67acd5-5b67-433b-bad9-c5a86f119d29">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7e27b6fb-4fc8-42fe-9fe5-2704b1488e51">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b16fbbdb-b0f6-4f3c-8c77-03f13cf18878">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_681a6d27-5179-4033-87d5-fa922e5ff15f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57012fa8-44a1-41d2-9e38-8f3fe35a2fd1">D<xref linkend="sect_CID_3718" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_64d8d6e5-e4ee-4875-bfdb-45037e41e80a">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9682c2d-762e-413f-872b-344802be6c50">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e8c54f6-d904-40c9-a788-1c384b305359">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c075f824-31b8-41c4-906d-ced22aef7956">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f4c6697-2569-4f7b-bd6c-c3ccc37f553d">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d1698dc2-8c04-44eb-86db-0231b9327e06">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fe94289b-e91c-4b8d-86a4-a92c578a42c9">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_073db23e-5037-4e70-a5b2-a14fff8fa984"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f3b0098-fcb3-4bc4-bd5e-4c8b046d182e">$Measurement = EV <link linkend="DCM_122495" xrefstyle="select: nopage">(122495, DCM, "Regional Contribution to Ejection Fraction")</link>
                                </para>
                                <para xml:id="para_5bc325de-c054-4691-aa8d-605c5600b365">$Units = DT (%, UCUM, "%")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7925cb92-47ba-4e22-935c-163d19c9b23b">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39325a0b-8246-438d-b833-940239972a88">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5161d022-fc78-401d-9d30-54af3174a3d7">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b360800-bd0f-4ac6-a3aa-905b8685dec7">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd9a626f-c1a8-47e4-81b3-bd7fc4306ab0"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cc031432-e111-4746-881d-5e8c41f5a78d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f0e5002e-2b89-4f44-a8ab-29623f498f88">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5bd7254-f7f9-45f8-82a9-452413a27884"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1cec57d3-6388-46bb-a0da-0eef8099f092"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_eb1ef3bd-258b-4ab2-9d97-72d74f3d123b">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_44864d25-9570-433a-a546-cb69651872b2">Row 8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dbe64cd5-11f5-42ab-97e1-27b316470a0a">Secondary Capture image with Landmark Based Analysis result. No purpose of reference is specified.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
        </section>
        <section label="Quantitative Arterial Analysis Report SR IOD Templates" status="2" xml:id="sect_QuantitativeArterialAnalysisReportSRIODTemplates">
            <title/>
            <para xml:id="para_0ed6de7f-7b23-463d-b4c3-d43d3ce589b3">The Templates that comprise the Quantitative Arterial Analysis SR are interconnected as in <xref linkend="figure_A-4" xrefstyle="select: label nopage"/>:</para>
            <para xml:id="para_e7989488-fcda-4722-9958-90f6594fe451">
                <figure label="A-4" pgwide="1" xml:id="figure_A-4">
                    <title>Quantitative Arterial Analysis Report SR IOD Template Structure</title>
                    <mediaobject>
                        <imageobject>
                            <imagedata fileref="figures/PS3.16_A-4.svg"/>
                        </imageobject>
                    </mediaobject>
                </figure>
            </para>
            <section label="TID 3213" status="3" xml:id="sect_TID_3213">
                <title>Quantitative Arterial Analysis</title>
                <para xml:id="para_31f3b134-d14b-4832-b28d-4356d60c4e6e">The Quantitative Arterial Analysis Template consists of a CONTAINER with a structure for reporting the result of the quantitative arterial analysis process.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_d7fd3f03-d31b-4715-83da-74c7876998b2">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_dea2a858-2ecf-4105-80f6-4a7a77c40cdd">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_2061fb25-68db-4627-bc81-4c6e83a117e6">
                                <emphasis role="bold">Yes</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3213" rules="all" xml:id="table_TID_3213">
                    <caption>Quantitative Arterial Analysis</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6a4286a3-5309-4840-ab6f-24757cb789cf"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4ce7ffcd-f5e7-452d-963f-7d0b9f1a71fb">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_140ca269-ac27-4891-bf74-86d2cd3afb5f">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b66389b6-4eec-4c9d-94af-b2f4166656af">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_22de4ae1-95a5-4b42-bda1-4aa3efa8d996">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb9280ba-429d-4f81-a292-bd7a7538edc6">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bb5e26db-4765-453d-a225-ccedb5d32d96">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b34d166a-5955-4962-b72b-fa35ac1c4bfc">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0f6a3001-784e-46a6-9ae1-436699d801dd">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11d3f572-d362-4051-a153-fc9665dd6e16">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8740c10a-d4aa-4b5b-8515-372bfa8a6acb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_020b06de-64f6-40c4-a094-a4956c18e27e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93bda312-d92b-4b96-a48b-dfe3948053f7">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e62a5c1-8f48-4d94-bd5d-33b0225320a4">EV <link linkend="DCM_122291" xrefstyle="select: nopage">(122291, DCM, "Quantitative Arteriography Report")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_28166ca8-b388-4fa8-82d2-165f02503124">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_677b3226-c98a-4169-9ec3-1a908bfb4c47">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a980388f-20b3-46cd-a8d5-620f773d4b7a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08665353-f73e-44d2-a2d9-650a883c0bc5"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2420e9ba-23c3-40cc-b182-3c474642d33d">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_68646211-2096-408d-9e36-5eead2a45b79">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b232d8d-3178-441b-935f-8e8c6a3e3095">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4f21819-ef22-42cb-bda8-9ffeda96f00d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a249c6e-a41f-45af-8405-edac7917aff1">D<xref linkend="sect_TID_1204" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c06bd77a-6a4e-48e2-86d8-c9d5a69320e1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_caeb1dc8-3e7a-41c3-9d80-7dc776048d2e">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ede444b-b3c5-4ad9-887b-ab8b2252a766"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a480054-7b2e-4b8f-b233-3c88219e46a7"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae1f8014-50c1-4b04-8e11-d18bafbe777b">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38b87288-f319-48e0-b1a8-48abfd34880f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec3c8a27-c521-4c9d-b514-ac0ff5412b81">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0de19163-51d3-43fe-b182-1095627af3d1">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8431fc1a-14e9-47ed-a6a9-ca1ecbe139b6">D<xref linkend="sect_TID_1002" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_904bc38e-f349-4f18-baef-ce410245c6cb">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_da6ed3bd-8a3b-4a7d-b0ab-55c1dc15e95d">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42980f09-7013-44d3-85ab-9f81e51ff94e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_140b1859-eb6c-4a60-8752-6369239d35cd"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4e2c853-9717-4823-9806-a7b4330f6f76">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2d1d451-5414-48a4-8390-c7b9d5101c3a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b7a36b7-de95-428a-8e58-d888f343cfad">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72354286-abd5-4c5d-9bb4-0f6f9f44186c">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fda80e6f-504b-4302-9fcc-9a6feb945593">D<xref linkend="sect_TID_3602" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_57cfe2c0-d268-4d19-873d-1c65f383d4b0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_90d11762-ab1f-48d4-95c2-45d15488b34a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02496709-8e1e-4c9f-9d80-9abdf887a003"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_903a0733-9276-434a-9f57-7e4ee57edee4"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fafddd30-5865-442e-9bb8-d2e7778e47c1">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e43c80e-7fda-47ef-8379-68865b6536b7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6667f01b-f528-4a0a-b9db-536deeadba6f">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_349b3770-f5a2-41a4-b3cc-fb97f0220302">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb7002a7-e717-4698-91b5-70e63db55dbc">EV <link linkend="DCM_111001" xrefstyle="select: nopage">(111001, DCM, "Algorithm Name")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ee919a08-0ba0-44cf-87de-ee522cf91d7b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4cf46fc4-7946-4ce0-bf88-8533a8c867a9">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8abe7644-2756-4013-9528-0f6895d69074"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2aae5d2-5fbb-4ae5-b88e-3d01aa1fdae8"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58620f65-ba62-4924-8e65-d9c96dda4d06">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88698d91-6e1a-45b9-8469-a6e813dab7d2">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c4bbe60-de3b-4e79-9df5-1e0ca43fd729">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73e22b4c-abe2-4727-8427-425841b5e262">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3dc72c00-55b4-4360-a307-db088680f559">EV <link linkend="DCM_111003" xrefstyle="select: nopage">(111003, DCM, "Algorithm Version")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_459e380d-5353-40c4-99f9-2e5986a42f74">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_06149a4c-cb73-4852-9dae-7b753912b36c">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b32b5308-b271-48ed-801d-e34960a766a3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52b3bf27-956d-47db-a461-068e064dc8c7"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d6a751a7-072a-4d04-928f-82cb101da09a">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b49dfa4a-40f5-4507-ae44-e628f860ac46">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02cdea51-bd2a-4ca9-8e86-a23737d94a55">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8fc4e86a-3c56-4daf-943a-1759d7449a6a">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7cae3430-454e-411c-bb5a-e1674df3f0fc">EV <link linkend="DCM_122405" xrefstyle="select: nopage">(122405, DCM, "Algorithm Manufacturer")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_021cc112-f646-481b-b2ac-be7d804ea364">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_339cb493-9d48-4be3-993f-8216429a729f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5adb46ec-4007-41ff-a348-48ebc9c51aaf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c64fd3b-6223-4ffb-9252-b3bc99b28065"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37a04944-9116-474e-90a0-79f975eb49a3">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e08487e2-5689-468e-a70a-690d1a594053">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3f7f7a4-5629-4025-96bb-d641b7fc9fda">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3eca6929-4dcf-408e-b953-baac0bb2422d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_050e7bee-bbb5-4f9e-be82-bc2f3545ea31">D<xref linkend="sect_TID_3214" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_34b97c42-0c7a-44cb-8363-dcd6e86df2c8">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_786ea490-f0e9-462e-a99c-bc03f9b908fd">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5588c612-3d49-4da2-9d7b-77177580599d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_958e0808-3b93-47b6-8fbb-89f8e8557064"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_3555aeda-eea8-4511-96cb-c107bbfa657b">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13b1c61f-b4df-4a59-a094-531fdc9e518c">Row 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff7525f2-e276-4ec6-af7b-3990b3e2576b">Identifies the Arterial Analysis program</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5928d1ab-998d-4b56-90a4-464268e9a2fb">Row 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00bb53b9-692b-40c9-b2c2-3a9b29c5f12d">Identifies the Arterial Analysis program version</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_107edefd-8e73-4384-9a22-cc17813e7e4d">Row 7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9cb9d11a-6904-4873-8739-7719c9febb70">Identifies the Arterial Analysis program manufacturer</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3214" status="3" xml:id="sect_TID_3214">
                <title>Analyzed Segment</title>
                <para xml:id="para_c4a79d91-519e-469f-908b-015f8f66ff74">The Analyzed Segment Template consists of a CONTAINER providing quantitative arterial analysis measurements derived from the angiographic images.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_fca946a3-8cc9-4031-b600-ce20a9238b37">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f7156c01-9294-4316-8dba-65300455f749">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_cb0dfa7c-2e26-4174-979a-b9a293ac85ca">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3214" rules="all" xml:id="table_TID_3214">
                    <caption>Analyzed Segment</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_09cfe0c3-77f3-4f70-baae-1102c9d30829"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8dabf6f9-9b05-4c90-b2f3-d254873104a9">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73008294-844a-43a2-b053-989be2fece6c">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_01003f06-349b-4c9a-ac24-2f18f9902698">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7e5df850-b20f-4a49-9a73-c40cecd855a3">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_938e3800-8c6a-4424-b789-29f4b63d9fce">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b63d0fb2-9bae-4908-99f0-714195459c83">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_015b8c38-db5d-4a1f-a781-7a7ddb99f3ec">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3b147407-c5d8-4d6d-bdda-9769f8fc61a5">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24ceb2b5-1991-468d-8c3e-9623813e8dd3">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a0d6c18-807d-49ac-85d1-7f98f9142cb6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_78f6da08-6316-423f-a0ef-639808bbf6c2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b12146a-16bf-4af5-9695-3314f6b301e4">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dea7743b-098b-408a-979a-bbf15e4ea3c3">EV <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f5a20453-1c46-49b4-89ea-b69a58a5a532">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85d77e02-9885-453c-a7d9-2bafaf757a47">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f08f119c-4db6-490b-9b1b-54dbe24dede0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd0ea771-028f-4aab-83f3-7db8c5d0fe4b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be0900da-b1f5-4296-ac2e-c5c88490d091">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f95dff5-0052-42f9-928a-464cfab5ae9c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4e37e45-9172-4f99-93c5-c6f43852ef35">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c6968369-7187-4e25-a183-ead494a1ce2a">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_45e03d6f-f18a-4d7d-b52e-1c4060f91dbe">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_242dc254-11d2-4f62-a6ed-fe50894345d5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c4a8267a-96c8-4d7f-a2d0-c7ad053cda5c">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5134dde4-a83b-4593-a340-fa53dacbe895"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d437d26f-639e-4fba-906d-ae78ddaddf0a">D<xref linkend="sect_CID_3604" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08431cce-2cf1-4fee-82ad-40a9dad0a09c">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c30a3aac-2789-4053-b7a5-0e29ec2f8e64">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0662f763-f188-4b5e-98dd-a7abf5711f17">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6fa89dd4-978c-4b7c-a54f-760265aa1094">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0cf4a12d-5707-448d-be23-49c9c18a9c3b">EV <link linkend="DCM_121112" xrefstyle="select: nopage">(121112, DCM, "Source of Measurement")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2353306e-4913-4a6b-b6ab-68efb8cd60b7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2023e9a7-50bf-4183-9df4-c6f734718d0c">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f281f59-1e0c-4bc5-9e58-8b9a2ece4c12"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1afb8d3e-60e7-48af-bb62-30c2ab293396"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e4fda9a-b311-4dec-ba74-890c09f04d79">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63d0aa8a-645e-44ff-a71b-002c9613d696">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_455a9c61-c964-4ea0-8a76-c0b748648475">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1cc26ddf-17f7-4482-ade1-5e34fe3a251d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b312428e-ec14-415d-b5d2-27a7eb750c98">D<xref linkend="sect_TID_3205" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_35ee72b1-51b0-4757-9de6-d592ed4ccdd5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ceeb7d70-0b5b-4955-840e-2a9d0a0a073d">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2cab689c-013b-4f96-9cc3-2100d23db095"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f11f224-c9af-4dae-a1ee-a6450b4149d6"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a55fc0d8-115e-4972-84c0-351bafe44909">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_862f30a9-dcf1-42e8-be33-357e053a8ca4">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67d29300-24cf-4a7b-b6bf-d5ba32561e40">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_934c393d-1b56-47ef-9e4a-abd6746672c3">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8109eea0-975b-4174-ac38-e870aeec938b">D<xref linkend="sect_TID_3520" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c8c7be86-b24f-4976-87f7-38882ad24698">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8119d7d9-53de-43e7-8f2a-bd0815dd46f1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69bf7eaa-7cd2-479b-9e2e-9aa2b4146b87"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af12e61a-86b4-4068-858b-b2f1da359e9a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_545093cd-6f42-4b92-ae83-6105ae2085a8">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1316ca3f-d1fc-428e-9a31-e8ad744c25eb">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4e505bc-89d1-48d1-8b68-a2ff1d02768a">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_347349ec-26cc-4f55-a9fd-4820a554c48a">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5741db4-0b7e-456a-a282-73cf650c3b36">EV <link xl:href="http://snomed.info/id/129085009" xl:show="new">(129085009, SCT, "Catheterization Procedure Phase")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_91598ad6-7a13-4d7b-910f-2d295e72b1d7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8c88d8a4-eed3-461f-9080-aeb787478a98">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_091efece-3d58-4f1c-ae53-8ff93a47e953"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b1f77fb-e2a5-4f78-b520-1b90dd8cb314">D<xref linkend="sect_CID_3651" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee09ae06-7efe-4927-99fd-807a00f73d87">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e1e4088e-12f8-4ba5-aa13-0604fd0c56f7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c252d51-c0e8-4cf6-bd94-214d706d4d95">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f97536d9-eabd-4c72-96fb-2fc134b42df5">SCOORD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6cc4e0f9-c6b7-4a29-9896-473c15aaa17e">EV <link linkend="DCM_122507" xrefstyle="select: nopage">(122507, DCM, "Left Contour")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ecf8a40-d20a-4b46-a5ae-32c04e1c58e8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_87a35b65-abf0-4e95-8746-a4d476068b7c">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f746a780-0aec-4e5a-95de-28d6a09a920a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09dffe6d-6fcd-467f-b444-b862ae43ca44">GRAPHIC TYPE = {POLYLINE}</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04ea3d09-7456-43b8-aadf-3d2c9ee9964e">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62533146-97f2-42d0-8a27-b9c8ef9157e4">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_245aa1c8-5f31-4f19-9cae-e0b666a4ba14">R-SELECTED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29306e33-24af-4c5a-ab19-9a27c40b1f3d">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b51e796-38f4-427a-a326-c8f4e5231591"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8088a8ce-726e-48c4-a946-b612ecae6d51">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_551beac9-d8ad-4b81-a7f1-70a4e55b1547">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5072ba0-4544-43ab-a62b-6d1bde0e047d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_245d7d02-3dd0-4c2c-bec0-9ddefb9042c3">Must reference Row 3</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_987354d8-10ec-40bf-b434-0312aa524ca0">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5246fa82-bd60-425d-964b-c876fbe545ae">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5f2bc00-0feb-4040-aa6e-36ba40c44541">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2587471a-c431-4586-b566-b6d8c5723def">SCOORD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b59cef3-8166-4d2e-8985-be468b6fbfb2">EV <link linkend="DCM_122508" xrefstyle="select: nopage">(122508, DCM, "Right Contour")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f354faaf-9eac-415b-838c-9542bde9e1bf">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0dec2dbc-c008-4099-8bb1-bda414f6f733">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65027114-ac32-48ec-b595-0aa8faa2fadb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_495a67ea-52f1-48e6-bf07-ceb839b4e6f1">GRAPHIC TYPE = {POLYLINE}</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96c5a3e9-9104-4f6a-be87-0cd9589e3c9e">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dccc03b1-5692-45d6-bb03-8a1cd524e127">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e9053fe-9848-4f07-bf61-5a84d423a998">R-SELECTED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7cbb027-3bd2-43b5-bc20-3e11c88a6a8b">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb01fc1e-9b08-4d09-9ac0-b7e595121489"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_211fa3d5-ae6e-4957-98d2-c579d034ad4f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d3a7aa91-82a8-4267-8fa4-7b88814f1c0c">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fbaa55bb-748d-4635-985b-40aa8edd61b6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_441f73eb-2055-4ed3-8669-d3a3cd22d370">Must reference Row 3</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c76d3148-bfa0-42cf-8261-2d4185f2350e">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_14220d54-dfb2-43b4-8792-703238b91115">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce6a7c16-b254-48df-b584-52f28e98bd33">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e4cf92a-1fb8-41e5-9f12-9d2e9fd64d52">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08468a4d-1276-4635-ab0d-1960f0ae8820">D<xref linkend="sect_TID_3219" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ce1f335-faf3-4e0f-b077-46a9cfde2d69">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e442bd7e-7678-4237-a24c-55b0e4b83e77">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ad0eef2-3d2c-4779-b50c-3f15011389f8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f6d61d9-f300-49eb-99bc-0a184aed663c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_94ea7d9a-e79a-427d-97c8-d92ddad092be">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0711359-bc02-4c30-b7ce-2045d4871abf">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_edc00228-7e99-445c-b1fa-7cc058905baf">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e230ec64-0d93-4e9b-9224-f08f0c2b0909">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3539562b-5b5c-43da-b9ee-d8b3f22d5fe3">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f3373595-49d8-4b57-9da2-1315504af028">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_115bfb4f-d423-4907-a486-4240e29c91d8">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4daa3cd5-4ca5-4ca0-bb9f-64d4119569dd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bec50390-ad72-43a2-b4d0-c1233421007b">$Measurement = EV <link xl:href="http://snomed.info/id/397413000" xl:show="new">(397413000, SCT, "Vessel Luminal Diameter")</link>
                                </para>
                                <para xml:id="para_8defea6b-be37-4362-ae5c-8488a710c522">$Derivation = EV <link xl:href="http://snomed.info/id/255605001" xl:show="new">(255605001, SCT, "Minimum")</link>
                                </para>
                                <para xml:id="para_93e04f01-1a43-4326-913d-bcb08e74fef3">$Units = DT (mm, UCUM, "mm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f0135a5-5006-4b7f-bdd1-8031b4b7d27a">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1846b28b-7e5c-4a95-88cd-7f1ab3e4a930">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_090754e9-e8ac-4f67-ab41-5c1c25034a11">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1264a3e-8a01-4948-b356-391c7766f357">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b79cb977-d7fe-4fb2-a8d9-39f423171290">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9efe2560-6ad4-43da-9f86-f485d4e92bca">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_36a0b4d9-a722-4a31-a3f8-0e44210a4244">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c089f465-aadd-467a-96ec-2649661f830e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6dd4c7a-4d14-4f22-9dd5-25f27cf6e0b4">$Measurement = EV <link xl:href="http://snomed.info/id/397413000" xl:show="new">(397413000, SCT, "Vessel Luminal Diameter")</link>
                                </para>
                                <para xml:id="para_bb00f350-682e-475d-8c1d-8f81ba2c0039">$Derivation = EV <link xl:href="http://snomed.info/id/56851009" xl:show="new">(56851009, SCT, "Maximum")</link>
                                </para>
                                <para xml:id="para_8b3bc06a-f1ef-4710-8802-b38ba0b3f0e8">$Units = DT (mm, UCUM, "mm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_442083d7-5fe6-470f-9f4b-eabae6c19d83">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4855ee88-7fbc-43a1-ac7c-1772c0c4cce5">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_454a96bd-2605-4400-93c4-1eb0839cd80b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57053e75-d5d2-4cf6-b4db-ecc102407b3d">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0264f9eb-45e3-4049-b1a5-bacd7227a82f">EV <link linkend="DCM_122509" xrefstyle="select: nopage">(122509, DCM, "Diameter Graph")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dfa5baa3-8c06-4575-8250-f6efd1335d50">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6d027c39-ce62-4c94-9ae1-5bb81d37be8d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a43313b5-27e8-4924-94e0-7aa8adf41448"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e3989a6-b380-4b7e-959f-b52948f05d71"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8357c5ba-11fa-42d9-a563-4159daf6f122">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf542b47-1fbf-4739-bf1f-6f3ccc46948a">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eecc3d48-0f8d-4e39-8109-f945faf2a5e3">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb93246b-d189-452c-9755-5356df71cefd">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_47f3e696-ef79-4b33-ac61-fe934d4d8a56">EV <link linkend="DCM_122511" xrefstyle="select: nopage">(122511, DCM, "Graph Increment")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_284bfca7-e377-4676-9e01-da68c77dca86">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_89640893-b66e-4d68-a40c-1c4fd6c1534d">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27b48278-588c-4fb0-9aad-e5ecc6785d3d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ad36ffd-8d07-42eb-beb5-8bfa6fe4f96e">Value = 1</para>
                                <para xml:id="para_86db8ac7-c23b-4bba-a190-f6523df5e6b4">UNITS = DT ({pixels}, UCUM, "pixels")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52bfe649-aebf-4f5b-b393-be926de1364b">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_823487d7-cc4b-489d-be61-a8c0bdb82fbd">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ea25aeb-ea77-430e-aba1-a3d37d13fba9">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c407a48-2ef7-4276-97b5-3ce732c577c8">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73b5e10e-7d32-41ab-982c-90aa3fea1c65">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d133c7a4-f756-4337-a16f-8a77b1ec84a2">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1d18db72-e59d-44ce-bc40-4ad065410637">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75f24eb8-9783-4984-8e69-72007c92c89b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_854243a0-4418-4d7a-a0f5-fe216cd0c769">$Measurement = EV <link xl:href="http://snomed.info/id/397413000" xl:show="new">(397413000, SCT, "Vessel Luminal Diameter")</link>
                                </para>
                                <para xml:id="para_ce547f82-a6e1-40f1-84e1-5e451d0b316b">$Units = DT (mm, UCUM, "mm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ec11cae-cff5-4da5-9e72-70058da78abe">17</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5eff048-bebc-441e-8617-6b5cba9b15a3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb1c0b6b-1f79-4a3b-83e2-ee104520c7a0">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e9295f9-7463-42d2-a0b3-f8b06a644365">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd7dc34c-6561-4f88-a2c2-e74c7e9ae5cb">EV <link linkend="DCM_122382" xrefstyle="select: nopage">(122382, DCM, "Site of Luminal Minimum")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c345b40a-a849-4283-91e6-664520470cef">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_42ca431c-20f8-4426-abd2-3ecbe52578a9">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cfc39df7-4e80-48d5-85f3-37a3924e2af9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da407d35-83e0-481b-8c48-8b2a47ff6c6d">UNITS = DT ({pixels}, UCUM, "pixels")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aae3c4f2-58a3-46bc-8d69-d56fc23d4ca7">18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f1f4a39-c213-40a0-8773-5e75fe2af669">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4dbe23ed-3675-4dc5-8618-215462e6d1c0">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8081d5f-2d55-4a7e-9f41-fa368fa4b051">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7cdefe04-f314-45c2-a95a-726a9cedee9f">EV <link linkend="DCM_122516" xrefstyle="select: nopage">(122516, DCM, "Site of Luminal Maximum")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4b96b796-1690-4d46-aea8-ae094f0aab42">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9272cb82-0e4e-4ca0-9caf-3a17587abe0c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c339ac40-2ca0-417b-8360-cb9c0977df7d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4f2ab39-dd45-48f7-9a9f-f591f40489f7">UNITS = DT ({pixels}, UCUM, "pixels")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b5b9d7a-d2f4-43df-845f-15d6bc06ae84">19</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73950beb-376d-4377-8f28-b9a0c447b231">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_048a4b89-8aa0-4c02-bd16-bb5aee7362a8">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2330621-173f-4064-ba5c-ff6a594833ac">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c44f97d7-3c3e-44ec-9bab-31534ee20d20">D<xref linkend="sect_TID_3215" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e92cead2-55e2-4b2f-8557-a2c1043f6de8">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e20c1589-48ef-4b09-b3b0-6ce1cef38763">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c2f41621-84a6-44bb-a747-3f0a5893fe81"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f4967f4-39a9-40de-a089-526c2df06bb1"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6107ceab-b617-4305-9f1b-3d50811436f3">20</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_842d532d-d609-4728-b53e-498783052f35">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17d88834-c0cd-4ce4-ac21-d59124d3d835">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8f8008a-3cb6-4815-a6dc-903d373efd1b">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4671be7-962a-477c-8949-13c6eab46787">D<xref linkend="sect_TID_3217" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_74da231b-0b68-4b2c-bbd7-fe67989115e0">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d3d0f371-e357-42c1-b205-abb44259f149">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1fadf1fb-4b6f-4551-bf89-ce34a60bcd92"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7563e554-39e7-4a80-a557-e11d8be7cdbd"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f12d175-8189-44cd-829b-ee213733084f">21</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8bede48d-19e2-4ea0-b51e-92d6d73077b9">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e50186e-f448-427e-8e6b-f15fec2c2b37">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_130c1e55-72c6-4edd-8c92-3bc9139790e3">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ba30cd9-8ef8-4593-8621-b7a8e1364b6d"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_49a692da-1856-4298-8595-2a0394cdd29d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_48e79b98-123d-4030-94e2-9bcb35fa5a80">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99dfd398-f42b-4863-b97b-a8cb61d192a5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9d03e75-9152-44a1-bfbf-a38fff53067a"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_6c8653d8-42f6-4e0e-97b6-1e7080669e85">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a7aae32-37b2-4f8f-8cba-20c74df8760f">Row 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fff96c09-3765-49a9-8ad2-46ae1ab6cfcd">Observation DateTime (0040,A032) of container needs to be flagged with the time of the analysis</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5fc8ceca-ba67-4877-b2ae-3b6aea6d6318">Row 7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6bb39daf-b11b-4cfd-b945-a5fa4493a742">Numeric coordinates (x,y) identifying the contour points from proximal to distal of left contour. Left is relative to the direction of the blood flow.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35f681e9-e5e9-4aa1-bcb4-a951e93a70e5">Row 9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c44c3093-528c-4da6-ba0a-5ea2f630bbc1">Numeric coordinates (x,y) identifying the contour points from proximal to distal of right contour. Right is relative to the direction of the blood flow.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b8987616-5d1b-4603-ba9b-7627bd2329f3">Rows 12, 13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af4bbe18-29cb-44e8-937c-f488cd8e67fe">Positions are relative to the midpoint between the first left and right contour points and measured along the midline between the left and right contour.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65874690-fc76-489d-9406-4dbc8ccde04a">Row 14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a41da8ed-7c27-41a8-a93b-dc11d09cc088">The X-axis represents the pixel points of the midline of the vessel from proximal to distal. The points on the midline are not necessarily equidistant.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_006d674e-19e1-418f-84eb-91c972b45cea">Row 16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a3421eb-f1a6-47da-99ae-98b7e0be8ebd">For each point of the midline of the vessel a measurement value for the diameter is calculated.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70094f41-8bf2-4ff4-a622-d35505222c21">Rows 17, 18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0408d169-5cbe-46a8-be76-4e842ef85de6">The positions in the graph are related to the points on the midline of the vessel.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4477d0ca-e5f8-48aa-a81b-c3e09d4fa5a7">Row 21</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf2acb3d-31fa-41e8-b0e0-21a40a13c58f">Secondary Capture image with Arterial Analysis contour. No purpose of reference is specified.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
                <para xml:id="para_bc62d525-ef2d-418d-90e6-112f54e10a19">Definition of Left and Right defined by the direction of the blood flow as in <xref linkend="figure_A-4b" xrefstyle="select: label nopage"/>:</para>
                <para xml:id="para_e865c588-ff5e-41d4-9bbd-c87a673c0fed">
                    <figure label="A-4b" pgwide="1" xml:id="figure_A-4b">
                        <title>Direction of Blood Flow</title>
                        <mediaobject>
                            <imageobject>
                                <imagedata fileref="figures/PS3.16_A-4b.svg"/>
                            </imageobject>
                        </mediaobject>
                    </figure>
                </para>
            </section>
            <section label="TID 3215" status="3" xml:id="sect_TID_3215">
                <title>Angiographic Lesion Analysis</title>
                <para xml:id="para_231ed8ef-e571-49f8-a733-92a7f17d2bea">The Angiographic Lesion Analysis Template consists of a CONTAINER providing quantitative arterial analysis measurements derived for an obstruction in a total analyzed segment.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ed683214-50f9-4b07-9794-e78a6309f8f0">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_780c4859-1300-41a2-b893-8279db047427">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f5881322-3f2f-49f7-9c65-be087dac4066">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3215" rules="all" xml:id="table_TID_3215">
                    <caption>Angiographic Lesion Analysis</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fea6a595-2e67-47d9-9d77-085bbf05d86e"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fbf1221a-f372-4744-94f9-7c785cdbc9b7">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_24aeaff1-69b2-4f84-ae0e-40cce64f3cc7">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_91b3224c-25b5-4dcf-ad99-45fdd47a3634">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_828d18aa-769c-43d8-bedc-698b7cd5ca95">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_043b5a6e-1a9e-4bbd-b5fa-96ec2575436e">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_526a6cba-4f60-485b-a866-b7c206b76ef1">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_10b40d0d-e250-4251-943b-89be9b202817">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b795176d-f3c5-4c9e-afa5-05611673b5ce">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c938388-0991-4230-b4ea-2355529e3e70">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d7729cdf-5e38-42e4-a071-ad64a81d1d85"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab01fea5-5c01-410f-a3d6-5591010f866b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5465aff4-3e80-4081-b9ad-0f1e40f5403f">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de4ecacc-1703-4751-9da9-c53bd3fb1792">EV <link xl:href="http://snomed.info/id/300577008" xl:show="new">(300577008, SCT, "Lesion Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7109f6cc-320e-49ba-97c6-c52e4aff269f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d29b6419-8bf1-40e3-9f8c-e4e5eb20c823">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c149df4d-cfc1-438d-a021-145e46942482"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48d0c711-3af4-4e65-957a-d40e63f8fd44"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d11987aa-d60c-48bb-a799-c1878b759bac">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a58c4c5c-4dd9-4224-917a-c3a569d79d88">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ad4ddd5-da03-4098-9061-f96666ce76a6">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d09e6ce7-7acc-4a5e-a37e-90e08d0ab9c3">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d86cd7f0-c290-45e3-8b0e-c7266f6fedc5">EV <link linkend="DCM_121151" xrefstyle="select: nopage">(121151, DCM, "Lesion Identifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c8a10ea5-796a-46a6-bf44-13fc336f4d9f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b32bd6b4-9fc7-4a89-b1ab-a2afdfc19b89">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_783ca9fa-b272-4e75-abb3-81755b9e867e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6bea4f27-e648-4081-a855-8c530c6716d1"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_722df575-1f8a-48d5-919b-96e15a5b5cb5">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2cb4462-2a7d-4c3d-8244-a8c4627f51fa">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6329cc3-323c-4066-b4f2-baecf6e2248f">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6062bf1d-74b4-4098-b264-d54924184b76">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cfa6f7ae-abd8-4a89-b935-57416760c6e3">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_76dea671-4994-4d02-a5e5-dbe266298d9a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b7f7ebaf-f36e-4f95-9f12-0215e38d5d2f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f769dcf-e7b4-4943-9bda-42032cd3805e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d763d81-c590-495c-a158-899730c55613">D<xref linkend="sect_CID_3604" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8fb5cd34-b430-480a-855b-7d21ed86624d">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d2091c1b-20ab-4f34-8c16-5feef854361a">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fad80e68-b16e-4c3c-833c-ed36244ad3a5">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5743e97-b23d-4309-adff-0a14ea418193">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9db72437-1fcc-43a5-a36d-79b765bd4cff">EV <link xl:href="http://snomed.info/id/106233006" xl:show="new">(106233006, SCT, "Topographical modifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3d3537db-1f38-4c37-b961-bef1f764c7d8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6077d0f8-a8e8-470b-9ac8-1d3de4dee760">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b53d4f1-06a1-4dd8-9012-e63307cc511f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_19b8028d-c220-46d0-b6c4-dff12be50d18">D<xref linkend="sect_CID_3019" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4206b27-6f1f-429d-b8e8-680d5ba615b1">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d59974e-7c2f-4cd7-97ee-15b0c75ab240">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09872487-a9e5-46a7-8acc-52bc3a291a9e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_94f94250-0b32-4255-a17b-4f874de720c6">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f730b71-7877-48f0-af1e-f55571518fdf">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0b7dd913-9e73-4572-b79e-7ecfd7a33187">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_90fb0b8e-08ab-4154-a97c-3954270eae55">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b940d6f9-b77d-438f-9ee1-11d5e3c34a89"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_db083de6-a218-4a02-a110-476cc76ed6f4">$Measurement = EV <link xl:href="http://snomed.info/id/397413000" xl:show="new">(397413000, SCT, "Vessel Luminal Diameter")</link>
                                </para>
                                <para xml:id="para_00e93f8e-9eba-46c7-9e9e-b1ea36497ffb">$Derivation = EV <link xl:href="http://snomed.info/id/255605001" xl:show="new">(255605001, SCT, "Minimum")</link>
                                </para>
                                <para xml:id="para_d1a2dee6-7290-4267-9657-4bbb0599da19">$Units = DT (mm, UCUM, "mm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13b2a320-a05b-42b0-8022-c81e13a28360">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b779a25-35c8-4e78-8a9a-c740d7c18aa6">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03518e2e-e4d8-4b07-9630-b35af52b9d16">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_164774e0-f528-40b0-a07b-b005c1d8c31f">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4c2b878-5a1b-46e0-aafe-547eb09e016a">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0ff69078-84ae-4611-b754-1d0b4617d302">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_abec2278-8cf3-404a-a7b3-72350ace95f8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea5b5006-c87f-4b17-a838-502e258b6463"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f3b46ec-5ca7-4ab0-a6b3-af058b9e9a1c">$Measurement = EV <link xl:href="http://snomed.info/id/397415007" xl:show="new">(397415007, SCT, "Vessel Lumen Cross-Sectional Area")</link>
                                </para>
                                <para xml:id="para_dae816ba-5122-4549-b625-6717af34198a">$Method = D<xref linkend="sect_CID_3470" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_e12faf36-d080-44b6-8e26-194f8c86a957">$Derivation = EV <link xl:href="http://snomed.info/id/255605001" xl:show="new">(255605001, SCT, "Minimum")</link>
                                </para>
                                <para xml:id="para_72a6044d-326c-485f-9f89-0fba2106ab35">$Units = DT (mm2, UCUM, "mm2")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e083d55d-73a9-4a6b-bb77-9bb336a79d2a">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1f03bc82-5440-4b7d-a38b-6da5042157e6">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6a31c31-bcc3-4fc9-8451-06213a325ab0">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_673e0ada-d11c-4ee5-b5f1-c94a4910a0ef">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8954d234-6179-4cf3-85ba-47f3bf24e21d">EV <link linkend="DCM_122430" xrefstyle="select: nopage">(122430, DCM, "Reference Method")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_501bacce-2a17-485e-9c22-918dfda9a79e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_677e9020-3a4f-4564-939d-ecd4cfdb7180">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e63357b4-4cea-440a-85c8-1c22ec00060f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_577db3a1-57dd-43d6-a6c5-292e32ef548a">D<xref linkend="sect_CID_3465" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eebfee7d-78d1-4de8-9a3e-d703376d765d">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29bf2eac-f027-4600-afbf-482b8f7e0aad">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a74f1fd-7bd5-46b6-a03e-f77bc5378a90">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_64642b84-7645-4d5c-979d-74fc7642bf65">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb1790ac-7d54-469f-b901-f0401db0ca43">EV <link linkend="DCM_122438" xrefstyle="select: nopage">(122438, DCM, "Reference Points")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf328b2e-39bc-40bf-a878-419593dfd3ab">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3a524dc3-21e6-4ab0-96da-d9e18c45507e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08265136-0e86-4e34-9840-84e7f4231434"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7aa07d9-3c7b-4c4d-8fb1-93973a26802c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_faf70902-f0ca-4b6f-86a6-a64bfa46c8bd">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_026b3d09-c303-4b54-abbb-faf247447596">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5868e1d-c6cd-467a-8836-322830ea4e4c">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d35323b6-7238-4266-8a43-39b102d16de3">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af6a89cb-a952-49c9-9c97-eea72dbc4db0">EV <link linkend="DCM_122337" xrefstyle="select: nopage">(122337, DCM, "Relative Position")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_16c83c9a-27cd-4065-b665-340ff9eafb50">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_da794d89-d26a-4ad3-8366-4f8e4e6a8df1">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9a46304-3230-47e5-aa66-8ec98e616a2c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24a6970c-ef72-44b3-8ca1-0b75a1b8f332">UNITS = DT (mm, UCUM, "mm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29a450ed-4f1e-42da-8d37-cb4a7f1813d5">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f195135-558c-4bcf-aab1-d21fe96a91ea">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_44114d71-86a4-4d81-a2b8-c286c1b39096">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ef87948-9f1f-4760-a30f-1ae56509f717">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c2eaf426-e08b-4257-b99a-add2a3d34da6">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_99cdc634-97f4-4be6-b452-c35c34adb27f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_83fd4143-afb0-4572-bb95-f69ff2222932">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_977489a1-e9ee-46bb-91fb-cfecaf8b60ea"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff6a1d8e-2681-49f0-9702-6d89dba10685">$Measurement = EV <link xl:href="http://snomed.info/id/397413000" xl:show="new">(397413000, SCT, "Vessel Luminal Diameter")</link>
                                </para>
                                <para xml:id="para_75ed0f83-9ca4-49b7-a9e9-2042a1d9b500">$Units = DT (mm, UCUM, "mm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f23b0964-53e3-40f9-89a1-da94a94e4490">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1aa45268-86c3-426c-8381-8cd93bb44311">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd0aa0e4-12a2-4ca5-9c36-59b93e96ae71">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ce6fdd9-7f5c-4d69-a2a7-2a0bafbd8a63">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e8f28e50-52e7-4739-9246-a838106c0c75">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_de1b7967-0925-4f4c-b1db-c28de0dc1bf3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_38f50393-8905-49f2-b29f-038ceec20e59">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b43a9f5d-270b-4db9-aef7-39bd2e295d4a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1835726f-e3b3-4a51-915a-b9446b426f10">$Measurement = EV <link xl:href="http://snomed.info/id/397413000" xl:show="new">(397413000, SCT, "Vessel Luminal Diameter")</link>
                                </para>
                                <para xml:id="para_cf1d538f-1403-41ac-8033-c4eb891dc553">$TargetSite = <link linkend="DCM_122382" xrefstyle="select: nopage">(122382, DCM, "Site of Luminal Minimum")</link>
                                </para>
                                <para xml:id="para_02843388-d475-4ab5-8d2c-f72b408a4925">$Units = DT (mm, UCUM, "mm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d506d2dc-424e-4502-8535-7f89dcf087f2">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b9a530f6-8cd5-45c3-aef2-5df609a5fe03">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e508f2f-094c-43de-bd6b-870028e0e01a">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2f9afbe-a61e-4c65-bf4f-de261c45111f">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_459f66c8-fafd-45da-a78c-bade04418fce">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9b4b6e6b-6b67-42bf-845a-ef43b0ac0409">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b99ac5e5-d2b6-47e9-beae-dd3d6d9a18d8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79623a48-5f59-4b29-880c-8852d92b4092"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7074d861-9ef2-4328-82fc-32837598052c">$Measurement = EV <link xl:href="http://snomed.info/id/397415007" xl:show="new">(397415007, SCT, "Vessel Lumen Cross-Sectional Area")</link>
                                </para>
                                <para xml:id="para_cbca2afc-d2dd-4e9f-a57f-40e58001421e">$Derivation = EV <link linkend="DCM_122404" xrefstyle="select: nopage">(122404, DCM, "Reconstructed")</link>
                                </para>
                                <para xml:id="para_2898883e-ce98-4a59-91f9-8aa1baac9581">$TargetSite = <link linkend="DCM_122382" xrefstyle="select: nopage">(122382, DCM, "Site of Luminal Minimum")</link>
                                </para>
                                <para xml:id="para_c362b41c-ead2-47ff-8302-a0e4a2c5af25">$Units = DT (mm2, UCUM, "mm2")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_679d1c9f-f9fd-4314-af79-2b499dc03e18">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2dbe1d3d-69fc-4f72-8d26-75bd5ffeee2e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9d67c9e-cdc3-45dd-af72-87041ca2bd49">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_327b7b3f-e4f5-466f-a326-4b2468f50934">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4da191d6-d110-4b63-a468-cddcb2536744">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bdcdb8c8-4cee-409c-a74b-a496cb607c56">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c280013-af2e-4d10-8b0e-24ff916d0b0e">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4061451-ed71-4f3c-9c33-e272ff840be4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee6e35fe-03af-4a85-8175-5574abdd2987">$Measurement = EV <link xl:href="http://snomed.info/id/397413000" xl:show="new">(397413000, SCT, "Vessel Luminal Diameter")</link>
                                </para>
                                <para xml:id="para_0c7042aa-9935-4023-8c21-742353c1aeb8">$Derivation = EV <link xl:href="http://snomed.info/id/258090004" xl:show="new">(258090004, SCT, "Calculated")</link>
                                </para>
                                <para xml:id="para_3bf78d5e-09c8-4daa-a634-735a06b9ad6e">$TargetSite = EV <link linkend="DCM_122481" xrefstyle="select: nopage">(122481, DCM, "Contour Start")</link>
                                </para>
                                <para xml:id="para_d043ffec-a7da-499c-9a4b-300342083901">$Units = DT (mm, UCUM, "mm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f7f45bff-09c7-4ac6-a35c-0f8b7e9b8112">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4c1f1d3-59ab-4dc9-9519-f655ea43f53b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0e29651-16bc-4691-9069-cf0686198f42">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9ae1f65-dc2b-43b4-8694-469388f577b3">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_32c56dd9-a739-4b1e-9422-f8abf1f1717a">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c652286f-3011-45a4-bfef-e5a66983de4c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_14e99a99-e829-4efe-9af4-c9e83b10f64e">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d85339ef-897a-4b9f-a746-2725a541e348"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e11056f-f787-41b1-a039-8c97cd7dbc16">$Measurement = EV <link xl:href="http://snomed.info/id/397413000" xl:show="new">(397413000, SCT, "Vessel Luminal Diameter")</link>
                                </para>
                                <para xml:id="para_f70eec54-0cb9-4641-9db1-23e7b1a507b4">$Derivation = EV <link xl:href="http://snomed.info/id/258090004" xl:show="new">(258090004, SCT, "Calculated")</link>
                                </para>
                                <para xml:id="para_1b598e78-4bf3-4ce7-8afb-8ce028daa14c">$TargetSite = EV <link linkend="DCM_122482" xrefstyle="select: nopage">(122482, DCM, "Contour End")</link>
                                </para>
                                <para xml:id="para_7830e169-ecab-4253-a957-42e6a2a2dbf1">$Units = DT (mm, UCUM, "mm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de296583-28c0-4c32-abcf-688edf68610c">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c549ea8-b561-4f66-a604-e3c1963fb9f8">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1462687-e445-4f17-ae13-df3cd72f114d">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a209f03-50cd-48a2-a810-b6b1dc383748">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72459a08-a47e-4392-ad16-9137840b3b60">D<xref linkend="sect_TID_3218" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_82181e4b-40a1-42b8-956f-e7079b9188f4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_99989cd2-9251-42c5-9d73-f4246f70d9b4">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5b021ac-48d1-4c71-b429-b31527e90762"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_07653e4e-33a3-47a9-ac5c-518823c23f3b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6408912a-6d90-420b-8cfd-1ac2288d6c12">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4220d8ba-2897-4435-a5b9-e494dc5ab1db">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e294958-60ec-48d9-b871-ba4c24fc8fa9">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_936b5655-3613-4538-ad0e-7bed90aaf0af">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b84378c9-be7c-4308-aca3-2706732b56b0">EV <link linkend="DCM_122517" xrefstyle="select: nopage">(122517, DCM, "Densitometric Luminal Cross-sectional Area Graph")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f26de5ca-a8cb-4648-ab94-f31efe5f1704">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5fa6c25a-a9ef-4d5d-977b-2e5cab970530">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d7ae2971-ca62-4764-afda-3f4cfbae07a5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a19cc80-5c18-414c-a60e-c556d7b30726"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_284c0ca4-57db-45ae-8efa-77b5b4034fa0">17</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab7a7ed8-0d77-4bd7-9f85-8aa4e34e94ae">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c1b13e5-88b7-4b21-b07c-0e4603811bbf">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5bcf47c7-4883-438d-965f-debed51a2bb9">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c794d5d7-47ad-43bd-baac-60703603e1e7">EV <link linkend="DCM_122511" xrefstyle="select: nopage">(122511, DCM, "Graph Increment")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d3522de2-f3f6-4fff-a736-148e09936e83">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_96405efd-0996-457c-b626-c007641297f2">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_802dee20-e7c0-4054-bf24-9e214350dc56"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f12812a4-61f9-4d19-a132-102b85a320af">Value = 1</para>
                                <para xml:id="para_3ae898f6-213b-465f-899b-a5f3ad6af5e7">UNITS = DT ({pixels}, UCUM, "pixels")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce5a57e7-be29-4394-b481-35c1aefc81a2">18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_89eb2048-34bd-444b-9345-0e0f567a61a4">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_909d98c3-5f22-4acd-8398-d08e01cb441d">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af702c30-9b9b-436a-a287-f3fcccbcfe62">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35f1bf4d-064e-4706-84e5-51c963272c78">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ec202b44-1833-41dd-b1ff-fa4d43a72acb">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4883cd64-e55a-469d-849a-2a2d715b3189">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c03665b2-40db-4ae4-9e2f-2a73d860ee16"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_40f5778d-9651-4d5e-8891-2c17a12dc776">$Measurement = EV <link xl:href="http://snomed.info/id/397415007" xl:show="new">(397415007, SCT, "Vessel Lumen Cross-Sectional Area")</link>
                                </para>
                                <para xml:id="para_ce17f49f-ebd5-42f9-9892-9fa052886811">$Units = (mm2, UCUM, "mm2")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec4dd4c0-feb7-405c-80a5-0cc7bac42e90">19</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7563bd6d-d3c3-43ce-89d1-54cbc8de57ec">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8895aae9-280c-4d7c-bffe-596ca96b525d">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a78138be-5ef1-4c65-bf64-a9c1da6ffa63">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0fabfa3f-5813-4800-9714-cb2db3dbf3cf">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b88e7f01-99c6-4381-a8ae-01e79bffb3f7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c6a239e4-d285-43cd-9aa9-2036be77c727">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bead1a44-46c6-4ba7-954f-1c0ce4595764"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e94add1a-1430-4394-915e-3a83183417d4">$Measurement = EV <link xl:href="http://snomed.info/id/397415007" xl:show="new">(397415007, SCT, "Vessel Lumen Cross-Sectional Area")</link>
                                </para>
                                <para xml:id="para_54eef8cb-3810-434c-a902-168d07858dd0">$Derivation = EV <link xl:href="http://snomed.info/id/258090004" xl:show="new">(258090004, SCT, "Calculated")</link>
                                </para>
                                <para xml:id="para_b480ecdc-28f7-4a6a-b700-ba5988371604">$Method = EV <link linkend="DCM_122474" xrefstyle="select: nopage">(122474, DCM, "Densitometric method")</link>
                                </para>
                                <para xml:id="para_d8ad4a4f-d3bf-4d51-a811-a9e6441dd636">$TargetSite = EV <link linkend="DCM_122481" xrefstyle="select: nopage">(122481, DCM, "Contour Start")</link>
                                </para>
                                <para xml:id="para_6e240591-fbf2-44e1-a0f3-9b90ffced9f6">$Units = (mm2, UCUM, "mm2")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7a0f4425-06c2-49a1-a46c-d131fd65880e">20</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_991584bf-4859-4032-9d8d-d1e02e551846">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93ac5619-474a-40a4-bda2-bd7c4f053fc9">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ac4aecd-45db-42c2-b148-d20a1d092696">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97edbac0-39ea-44fa-bb06-e44a60faa13d">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3fff6718-66f4-47eb-a969-d987da1af2ab">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0ff10daa-96ba-431e-bf50-37046a80393d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c47dce5-f99f-4e7e-9be2-8d8cdd55d4bf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4907cb8-a63c-46a4-a1e3-998e5bf7b930">$Measurement = EV <link xl:href="http://snomed.info/id/397415007" xl:show="new">(397415007, SCT, "Vessel Lumen Cross-Sectional Area")</link>
                                </para>
                                <para xml:id="para_ae00e249-50da-4e3a-a71c-99f491cbeb2e">$Derivation = EV <link xl:href="http://snomed.info/id/258090004" xl:show="new">(258090004, SCT, "Calculated")</link>
                                </para>
                                <para xml:id="para_885c722c-6156-458f-bbee-71ba752951af">$Method = EV <link linkend="DCM_122474" xrefstyle="select: nopage">(122474, DCM, "Densitometric method")</link>
                                </para>
                                <para xml:id="para_c1cdf438-c09a-41c7-8874-10e378becaa6">$TargetSite = EV <link linkend="DCM_122482" xrefstyle="select: nopage">(122482, DCM, "Contour End")</link>
                                </para>
                                <para xml:id="para_49533f98-7c46-49e0-a45a-3147f9da63a7">$Units = (mm2, UCUM, "mm2")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_014ab90e-8499-44ad-bd90-7e364800e16e">21</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_53f26cbb-5869-4d1f-bd5f-1d999231a2e7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02388c8e-0ef9-4bc5-be58-2037ba5d54f3">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_232d7cec-eff0-49ed-bec1-e0af4b204620">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f59e7f7-92fc-4e88-9764-1023f0f784b9">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c9212103-3ef7-468a-a819-5e76845b6255">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1a5dc5cb-55f2-45e7-ae12-6651d9132728">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b6686db-cad6-4021-8c37-2991fcc67dfb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_232dc80b-c9f2-4ae1-b8b1-def9c4230c4b">$Measurement = EV <link xl:href="http://snomed.info/id/408716009" xl:show="new">(408716009, SCT, "Stenotic Lesion Length")</link>
                                </para>
                                <para xml:id="para_e1372141-8d5b-4c39-8e6c-344a8a101cac">$Units = DT (mm, UCUM, "mm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da5f161b-dced-4679-b173-4092365f4890">22</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54730952-969a-4c72-bd1d-ff2e4b2c473a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0df77f29-f88d-4723-8c51-f58534a343c8">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3fbbed76-97f3-4864-a3a6-efceb2ece68e">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_66267369-2482-4e0d-8c38-e4540ed716d7">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb4fe67f-f72f-4c39-8153-bc156456cd82">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eb4da81a-6808-4936-8a5b-00c572d172ca">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8428489e-e2b7-4ebb-8aed-4ed7ed5feeb7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f02f753-86b6-4890-aba4-e955c2a00fbc">$Measurement = EV <link xl:href="http://snomed.info/id/408715008" xl:show="new">(408715008, SCT, "Lumen Diameter Stenosis")</link>
                                </para>
                                <para xml:id="para_3b545472-11f3-4bf4-9796-92c8ab0605c3">$Units = DT (%, UCUM, "%")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_972f395b-7f7f-4291-93bc-ccff4044e464">23</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00ec3572-7b24-42c9-9f3e-9986a3e0c91b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_752fc62a-0f2c-4dba-a9d5-f47618819541">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3bcb3eb1-7428-4784-b11e-e0bce97eb92a">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22101504-d186-4ee4-a033-0c8f867eaea6">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3a6b8b8a-6bb1-4d43-8f78-4351d576727c">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e43d8005-7024-4726-b8dc-af80d5e3dd4e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f37a858c-fec1-4969-914c-2abcc083dcb7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e7c6061-6ea0-4240-b56f-8378630cb7e2">$Measurement = EV <link xl:href="http://snomed.info/id/408714007" xl:show="new">(408714007, SCT, "Lumen Area Stenosis")</link>
                                </para>
                                <para xml:id="para_5fcd5664-be40-46f4-aa79-c6f8cfe4d5ff">$Method = D<xref linkend="sect_CID_3470" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_e1184200-6f49-4633-9c7f-17c134e157c6">$Units = DT (%, UCUM, "%")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a81ec97-3faf-450a-9821-32420a47636e">24</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a14f9dd9-5afa-4c17-a984-a54ee43d7140">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_898a857a-2e8d-40a2-85fe-a2ab7e25acad">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ab0438d-536a-4f6a-85ca-6d0d001d562f">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_310581ba-1edf-4bbb-a9d1-38e418599b9c">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bddbd48b-7e21-45dd-8f41-4f8f60115562">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ea9e0185-ae9d-4849-a9b4-12908275f4b4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0cd0ae58-749b-42ef-95cb-bc2e65b6a026"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b203e81f-3229-4c1c-ba00-127f902429d9">$Measurement = EV <link linkend="DCM_122372" xrefstyle="select: nopage">(122372, DCM, "Lumen Volume")</link>
                                </para>
                                <para xml:id="para_e21f8a93-d38f-47f6-80d4-1f68742229d8">$Method = D<xref linkend="sect_CID_3470" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_4dbfa7fe-e10f-4dbb-9c39-c62537856310">$Units = DT (mm3, UCUM, "mm3")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5c73cd8-47ce-492f-916e-331d067b9849">25</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d7a7b52-2fe4-4f8f-8f33-740a34de9c1b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b47344a0-dd5d-4db7-bbf1-28995cc7e2a9">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13ae3a00-3bc0-46b1-beab-02632b6ce55b">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6736851-570e-4e00-a957-545d97071f7b">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_da472af1-f24c-40e8-b9fc-1fea3c030668">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5b8d00da-c7df-466c-a2d3-cd647135e715">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11770f30-55d0-4d6b-952a-3d139053e385"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_faf4eecb-e97b-4eeb-9bf1-4872b5a81fe2">$Measurement = EV <link linkend="DCM_122542" xrefstyle="select: nopage">(122542, DCM, "Plaque Area")</link>
                                </para>
                                <para xml:id="para_fdfcda8c-fba2-4374-b076-715b485267ee">$Units = DT (mm2, UCUM, "mm2")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_395c6d2b-fcae-47a1-bc73-d2a979bc3aff">26</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_45eb33a2-ea7d-4b13-8eb3-c13f8537a7bc">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2f90bdf-606c-4bf8-a02e-9fd1db343564">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_658dafd4-d148-4377-aa47-bf40d6e9ad37">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d0542d8-aa32-4711-8678-772f739f87fa">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3aeb242b-df62-4b56-96a0-242187e9e9db">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c6fe7e95-639f-4092-ba97-b8351bf4d611">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a882f901-fce5-4870-ba99-82ae4f29d709"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_731d28d5-8a9f-439a-b63f-90bd52b5de9e">$Measurement = EV <link linkend="DCM_122376" xrefstyle="select: nopage">(122376, DCM, "Total Plaque Volume")</link>
                                </para>
                                <para xml:id="para_04675de7-373f-4931-a856-f4f9dcd05043">$Units = DT (mm3, UCUM, "mm3")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb122566-de38-49b7-967b-faa74723cb48">27</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a031ac0-1a72-4ac3-a8d5-d7569cbfb017">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b3eac61-0a71-4ac9-986e-8fe2099ff916">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_41ef9048-d30c-417c-aba1-639de07e5dc9">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_874b303b-177f-4d59-8b28-33a0e561a4c3">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a51b8faa-ce3b-439c-8ab7-933bc77c3caa">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_87e316d0-fd76-46a7-a98b-05389559c70f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7804b297-fa8d-41ee-b794-fd9b897b0ced"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e622b229-41df-4ef4-a383-f0fb93343669">$Measurement = EV <link linkend="DCM_122544" xrefstyle="select: nopage">(122544, DCM, "Diameter Symmetry")</link>
                                </para>
                                <para xml:id="para_abd50815-14f4-46b4-bcb7-a17bb05d2c0b">$Units = DT ({ratio}, UCUM, "ratio")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd8724c7-317c-4e19-a530-bd4aa73e3fa5">28</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b88dc65e-6be2-443e-8a92-d4b0714316c4">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_611f3af5-699b-48ac-a843-43bac5534d42">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7340b29b-d07a-4c66-b26a-24ee491ceaf3">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df3f4655-df5d-48d5-962f-a141e10be06f">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_79354440-b5b5-49c4-8b7b-f6e7c6aa30e0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7df17f94-722a-4f4e-b20d-c5caeaa91c07">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_322791bd-bda6-40a8-8a97-97198a59b2d8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e86ed1f-19c5-4a6b-be9f-9eede4210269">$Measurement = EV <link linkend="DCM_122545" xrefstyle="select: nopage">(122545, DCM, "Area Symmetry")</link>
                                </para>
                                <para xml:id="para_4e17e713-65e7-4523-a75d-720fb7acbd27">$Units = DT ({ratio}, UCUM, "ratio")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3aa95f4-f636-485a-a5ac-bf56e72a26ce">29</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_702325a5-a47a-4370-bca7-ca8e0a46dce1">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_822d01c0-1d9d-4438-8607-005c1d92b74e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb671d78-dce3-4d1c-b990-d576fb45797f">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b47b2cab-1da3-4601-88f7-55db02f803e1">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_514cc1ee-9905-4b73-b3ba-eddbb0ee9505">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_162b829c-86bf-4915-b2b3-65c8ea5b0226">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_792a0e99-ce1a-4f68-84dd-bf02d2a6abba"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d01dfc27-067f-4de8-a6f6-f5ec094beed5">$Measurement = EV <link linkend="DCM_122546" xrefstyle="select: nopage">(122546, DCM, "Inflow Angle")</link>
                                </para>
                                <para xml:id="para_9cffdf65-a0e6-4eb7-87d2-63721b4db641">$Units = DT (deg, UCUM, "deg")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_000b297b-9744-468e-a5f7-743e14d3e81e">30</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74d1daf7-27fb-49d3-9bba-86cbd05083b3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_842fe6e9-740c-4590-b890-161abdc8e1f6">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a984cad-4f1e-463e-b371-9a082964be4a">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae0958c0-67ef-4f92-8b77-613eb2d2351f">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5c1dd344-5e69-4132-a41c-8818fe1c0ba1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a525039-6ae8-4b0d-8f18-df6e695d0657">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a7926e7-f934-4085-8c7d-157d72af0a5c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6cf1a303-0146-4a61-946f-59dd9bf4906a">$Measurement = EV <link linkend="DCM_122547" xrefstyle="select: nopage">(122547, DCM, "Outflow Angle")</link>
                                </para>
                                <para xml:id="para_aef3f449-16b7-4942-9d77-a17bf37aa97c">$Units = DT (deg, UCUM, "deg")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98bd15d0-3109-44be-bbac-2703d4bfe1f3">31</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8045f698-405c-4fe3-b34c-84df7ede1e70">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_814fda87-4430-422b-911a-30b309ff11f7">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4dd27e08-d504-4797-8ad7-a1a2ce12a19d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_326964cf-5a24-4a33-a0cf-3b043c34c3e3">D<xref linkend="sect_TID_3216" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c40831b1-d26f-414d-b6da-164826411e5f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6feabab2-e2d2-4250-ab61-b679b419421d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f61f04ce-9c15-46ea-9629-d05a279949ce"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_491d31a2-78cc-47d1-a04e-ce7d26110a6a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_117b627d-7178-4ed2-adec-0f3bc572ee3a">32</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69f8362c-d694-4401-81a5-8b5ec53e1160">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e86e35d0-e1fb-4f5a-b2c6-e19ce4c795b2">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_333fc883-01b1-401e-8597-f706e801dcf4">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a798dca4-8994-4179-a26d-a92a60fd98e4"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fa5f8931-3ae2-4717-93c2-e00277f1468d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6a71c901-536c-422e-bd8d-b4b62ca80fb6">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37b1b0ed-fd13-4160-99b8-59b18d6c86a2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1fe8f028-485e-4670-959c-bbbf21c4f6b9"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_84dc7dd8-f001-47c3-a412-d2c5830217c0">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f6535f2-6a2e-4588-bc0a-fd5a2d64c323">Row 8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c71d28c9-65a2-41ce-b113-294646a4d844">Set of user defined reference position for method that requires local reference position.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d14c566e-4400-4886-a3dc-99c70e22446f">Row 9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b25a9c4-64a4-4fcc-9f22-58a6f6f35456">Distance of local reference position from an arbitrary landmark.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ba63a4c-18f0-4dd8-a552-8d05a1157f4e">Row 10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81e16279-bd24-4848-a27f-00f551aa8310">Diameter at a local reference position.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84eb7f2d-ce4e-4637-b480-ddb3fe9db529">Row 11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f7bfe2b7-b061-4855-b9be-25a4723001f9">The reference diameter for the arterial lesion calculated with the applicable reference method</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84378cfc-d7e2-405f-b138-9ede47b7601d">Row 12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f8059ac-9a99-424a-b02a-ef332ddd2823">The reference area for the arterial lesion calculated with the applicable reference method</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3be970a3-bd7b-4416-9825-b27364990cd5">Row 13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ed5e8c6-6134-4f97-964f-bd501b59a53d">The diameter measurement at the start of the reconstruction line in the diameter graph (<xref linkend="sect_TID_3214" xrefstyle="select: labelnumber quotedtitle nopage"/> Row 14)</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62cbb618-78b2-4d7c-941d-5e79d440c2a0">Row 14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10395f5e-8f0a-475d-a630-cebd2c984424">The diameter measurement at the end of the reconstruction line in the diameter graph (<xref linkend="sect_TID_3214" xrefstyle="select: labelnumber quotedtitle nopage"/> Row 14)</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_406d3b71-ee66-4af2-85c6-78e83e4da7ec">Row 15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2cbe7940-ac7d-4acd-8f0a-2b6316b89ffd">The positions of the lesion, borders of the lesion, etc.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf1abc11-cb2c-4f09-9d52-fedf83f63e28">Row 16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_669aa71d-51ae-4005-b430-cdc4e7d353b6">The graph with the calculated cross sectional area results based on the densitometric method</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46ecc73d-b0f3-48c6-af10-42793886c10e">Row 18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_56e6d1b9-7f52-4875-a6c7-ede65711f538">The cross sectional area measurements calculated based on the densitometric method</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1951c3f2-dda1-4066-bb2e-8829a2921395">Row 19</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8af7727b-2313-4f1c-a5ca-5898d4871801">The cross sectional area measurement at the start of the reconstruction line in the area graph</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_418db78d-e746-42c9-98d3-b46a91438069">Row 20</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93c163a2-6e2e-40d7-91d4-16314ce0c421">The cross sectional area measurement at the end of the reconstruction line in the area graph</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_49f61eca-d3c8-45f6-9bbd-c42342661d92">Row 21</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74b188ba-a827-4208-a27c-12c0ac26c3d3">Measured along the midline of the left and right contour</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1aca7b3-cb67-4760-842a-a1317e7f2d2b">Row 22</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04d1b1e0-a34c-4def-97ee-158a39ed66f5">The diameter stenosis is calculated as follows:</para>
                                <para xml:id="para_ee78e5fc-1cce-43c8-b605-a6f71a2a02c8">(Reference Luminal Diameter - Minimum Luminal Diameter / Reference Luminal Diameter) * 100%</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11c09861-4ecf-4f92-a153-60f6c4018352">Row 23</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd3aa38f-2016-4fac-9f92-6e86bbc6e4f5">The circular and the densitometric area stenosis are calculated respectively as:</para>
                                <para xml:id="para_087fa618-5427-4363-af38-2676e862c3f4">(Reference Vessel Lumen Cross-Sectional Area - Minimum Luminal Circular Area / Reference Vessel Lumen Cross-Sectional Area) * 100%(Reference Vessel Lumen Cross-Sectional Area - Minimum Luminal Densitometric Area / Reference Vessel Lumen Cross-Sectional Area) * 100%</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37b90581-d523-4ac1-b822-f7335c6e3176">Row 24</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ba9816f-1c79-4909-bd97-3300ca544508">Estimated lumen volume between proximal border and distal border of lesion (<xref linkend="sect_TID_3218" xrefstyle="select: labelnumber quotedtitle nopage"/>, Row 1 and Row 2)</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f4955fc-43e4-4bdf-b777-989e4b52a7a4">Row 32</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd1ba35e-df03-43d3-8559-586b95097572">Secondary Capture image with obstruction analysis contour. No purpose of reference is specified.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3216" status="3" xml:id="sect_TID_3216">
                <title>Stenotic Flow Reserve</title>
                <para xml:id="para_79264f48-ce12-4727-a8ff-1f7b419be1d4">The Stenotic Flow Reserve Template consists of a CONTAINER providing quantitative arterial analysis measurements derived for an obstruction in a total analyzed segment.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_bb9dc5b9-272a-4e79-b396-894d6431f591">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_688c4e1d-120a-4544-aec3-2768ec0224ec">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_982e9bfc-ec99-4e9c-9484-a40c2389561f">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3216" rules="all" xml:id="table_TID_3216">
                    <caption>Stenotic Flow Reserve</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c8d4195d-7a1c-44b1-a8e4-626ff101067c"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dbbd887c-6f0a-4f87-a1b5-69f7c382a698">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_29fa9b0b-e1db-4b82-8a04-5b04d2d5dbd1">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73b2ce1a-06b0-43d3-9147-4e4eff4ee90d">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_49a6c9fb-e61e-4274-ab1f-6cf3579bb6dc">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f9aac950-600d-41b0-b9b8-8d73d4990385">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c591ebf2-8893-45a1-b12e-3ae602c64f46">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ba4cabd7-6b70-4ac9-a005-d9ae413c5bcf">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7714d412-6bec-4f2b-973c-0716be777df8">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_53649cb2-e190-4f31-b3e9-05f8d90ecb80">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce9ca663-a47d-43ab-ab7b-6953bcc93adb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80754259-dc31-430e-8d61-b7ca3afffd78">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54ab3e2f-f097-445e-914b-6945258f60ff">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ade7aa8c-c707-4a10-a7d4-835a226aa413">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5914e605-0334-439e-82d8-b72c75df7e72">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_af85519e-15ed-40f6-a15b-e100a099e886">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50ef5411-b2ac-4004-8424-d7319092dfdf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df601b2f-88dc-4f0e-93bd-cec3a841c385">$Measurement = EV <link linkend="DCM_122548" xrefstyle="select: nopage">(122548, DCM, "Stenotic Flow Reserve")</link>
                                </para>
                                <para xml:id="para_8d484742-a5ba-43b5-8f85-f0111297f75c">$Units = DT ({ratio}, UCUM, "ratio")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eefdd9b7-1dce-4d16-8214-77b27d96f727">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9bbee07-84f6-45f9-b872-0f37ce3437e1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd72d788-7c97-40d3-85b7-61a14fb510bd">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_382180a3-303b-4705-a001-af251878c33b">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8196fbc3-6c41-49d2-9535-9965cf888cf5">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_48c54bdb-0751-4bb1-b6d4-b241724a5ebf">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d211c792-6dff-4340-ba85-48adf281d8b0">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_abedf652-5370-4b8f-a144-486f55dcc1ea"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5e50d7a-1ee2-4e4e-89c8-8fddb54ebbef">$Measurement = EV <link linkend="DCM_122549" xrefstyle="select: nopage">(122549, DCM, "Poiseuille Resistance")</link>
                                </para>
                                <para xml:id="para_22990964-75ae-4b6b-85e4-065246adb4a0">$Units = DT (mm[Hg].s/cm, UCUM, "mmHG.s/cm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_95029ab2-d4eb-4ced-885d-41d28c30838c">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8dc0d618-dc03-4f64-ab44-3d0f0097efff"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85023cbc-55c5-4f81-9a1b-1d2e6564cbf4">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fff07662-9c3b-4a2a-98d7-2c3f2dd71fc6">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c15c9599-65c5-4424-ac09-851abe1cf638">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cdfb0662-2b9b-439e-9442-ccd33c934059">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5a5e0c4b-0e89-4de5-8079-79ab98549447">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e7884c2-c64e-4313-a629-b08d936b104e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ab3dee4-9ccf-4367-863f-28ab7026997a">$Measurement = EV <link linkend="DCM_122550" xrefstyle="select: nopage">(122550, DCM, "Turbulence Resistance")</link>
                                </para>
                                <para xml:id="para_8d750ca3-78cb-4bf7-9822-34262dd00e04">$Units = DT (mm[Hg].s2/cm2, UCUM, "mmHG.s2/cm2")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35384cbb-fadd-49fb-b64a-ec3b198f0d07">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff928829-526f-4868-94c5-8cee0cecb758"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e0eeb4d-9307-4065-a36d-5924175d51b6">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b726b3c5-02c4-4c36-9c94-7b2acedc7f9d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ee0ca27-cbf9-4c5d-8b39-09f4d1ae8ab2">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_80739acc-5392-4e44-a0ef-583a280a09ce">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7e4fc7a2-c65f-43b3-be7c-26255a273e70">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f3631ec-ffb6-4c31-9351-8a97ac680ad7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d78d8e7b-2ffd-4bc9-a064-cfc3867ef5bd">$Measurement = EV <link linkend="DCM_122555" xrefstyle="select: nopage">(122555, DCM, "Estimated Normal Flow")</link>
                                </para>
                                <para xml:id="para_5c46b65b-3b24-4fda-a475-c5a80d61b1d6">$Units = DT (ml/s, UCUM, "ml/s")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_15e70394-a78a-4548-9a91-4502c114f379">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5784b956-23af-4681-bb35-548052ef7b29"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91539ded-b865-4f8b-b7db-c415dcb7e858">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_40290ae5-2c9a-46cc-92a2-24abd97eef22">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d255a477-a600-4cb4-b028-1517d422e728">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ed113eb5-f560-4422-b8a5-f19ebb3f95f2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5a3bdd9b-21bb-4e90-b8c3-8e0f37b7dfb6">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d6a4295-d872-476d-b900-fa191d8d5dea"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38734751-6f19-4eaf-ba54-f5fc03b550fd">$Measurement = EV <link linkend="DCM_122551" xrefstyle="select: nopage">(122551, DCM, "Pressure Drop at SFR")</link>
                                </para>
                                <para xml:id="para_e97facf3-e921-4e59-8aa7-f67336982e01">$Units = DT (mm[Hg], UCUM, "mmHg")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d0fe19b-0242-47fc-a89c-549d00a441f4">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8bb9671a-b7b1-46e1-b20d-a115a3d01c3d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_68a71813-a89a-450c-bd52-50a3c37a862c">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b161e732-1833-4681-ad11-e03ba7de7833">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0abbd380-af07-4c69-a34d-6edb3ddff061"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8cd3d586-a9ec-4138-adee-74ce9e903c7a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8988a938-e245-4e5b-bed3-12ca3d5fab72">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb4b74dc-1f0d-44bb-8a50-bbc6ad6bda25"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_94e1b959-e80b-4eb6-8ce1-8f9893604152"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_be0d1448-8662-4355-a72a-b4776a43022c">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae9b5887-f0e8-4c62-85cc-a5e5bdeb7e3c">Row 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2c2c0ce-8957-495d-9f5a-cd224add020d">Secondary Capture image with SFR analysis contour. No purpose of reference is specified.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3217" status="3" xml:id="sect_TID_3217">
                <title>Sub-segmental Data</title>
                <para xml:id="para_cfc23354-60b5-41b3-b5af-f97cf412dcf1">The Sub-segmental Data Template consists of a CONTAINER providing quantitative arterial analysis measurements derived for a sub-segment in a total analyzed segment.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4c404c0f-3fcc-4bee-b07b-20cc7efff6f5">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_d485e50b-bb56-4057-b1ae-ce42c756089a">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_1f6cf099-3db6-45e2-abca-f05016496ebd">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3217" rules="all" xml:id="table_TID_3217">
                    <caption>Sub-Segmental Data</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69ab2d2b-21cc-4019-992c-6d25ee9cb384"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7b50a6a4-98c5-40c6-b537-4dab553c9a9d">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_09a5e50e-0ac7-4720-8749-e2f056e382f2">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_156d5409-a01c-4e2b-a11b-0050908ee336">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f97fb94e-836c-4da2-a309-3b63f985f29d">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b08a355f-32d7-4c88-a9eb-e0881cadaab6">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_baa7e7cd-a790-41f7-bb86-b3543eb4d62a">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_37a5dee9-13c2-4d07-8dd5-12ee1f4c50c3">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7284f998-443e-46fc-9885-d40e00a28e6a">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11c65654-bcfa-4be2-848e-28fd193490b9">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_143c8576-c728-4c62-b8c4-8812ac5d3615"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fbd88ce1-fc9b-4d03-ad52-941ff5cad495"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39b269b6-c4bb-44b8-a67b-949945942fbd">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80beec1d-1757-458d-ba15-2d7bc9d26306">EV <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2c0ddfa7-eb75-4e45-b2cf-2a35ed076071">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c2325942-6de6-4a38-af65-623db84b3c71">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1174cf90-8267-4a34-944e-88d03dcca33b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c6d2d7a9-c998-4ac0-be2e-adcec0749b03"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2d731e75-4503-43f3-aade-ea6337f9eaeb">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a546e8d0-0294-4489-bfe4-a9707502b1fb">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_77980073-74fd-46e3-9d0e-e037d789330f">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef36cb4e-b1d0-4192-b334-29edccb4edeb">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3cad9eb4-3a28-467a-8240-404334b552de">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9462ba7d-3241-4c57-a074-d8a34bbe3988">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ad2656a5-fa48-4b9e-b83b-ff80e7e2327f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a83c5696-2a41-4073-8c3d-98bd4bd51834"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b51ba54-ae8a-44ea-982e-da8e5a4c063d">D<xref linkend="sect_CID_3604" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ec7de8a-3837-494e-9284-ed238588065d">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b30b4de3-fe2e-4e9d-bfa4-0891b3979c83">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd336aa3-fc84-470c-92f4-a71f447e94fd">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d83cd764-2b04-4b14-b469-ca3e833dbb28">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8128d18-ab56-4c8b-8863-318d8cc3f2d9">EV <link xl:href="http://snomed.info/id/106233006" xl:show="new">(106233006, SCT, "Topographical modifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e3751c9e-147b-40f6-843e-475bc8f6aff1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2176eb11-062f-44d6-8c66-3a451a6dcc11">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24a5e12c-d94d-412f-9277-9025e3f4fca6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b7785b4-5cbf-46f7-9957-b593b0a7575b">D<xref linkend="sect_CID_3019" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_78d7c778-2e49-48ae-805c-bfd2526e02a3">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_805d4522-588d-4a1e-95ad-b88ea4449822">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_266c755a-c056-4da0-8ab3-fb409fc8f873">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22cd0c30-23b9-49cc-8bae-76149bd75d2b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7dce85e7-dc62-4a99-9b32-de91789b656f">EV <link linkend="DCM_122554" xrefstyle="select: nopage">(122554, DCM, "Segmentation Method")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ae88e0d9-1464-4ae1-9a4b-d31774fba6f5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_63f3a7d8-7a65-4d77-850c-86c9610257df">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65b39c5e-6117-4ebf-93a2-266ec585260d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a42342fe-1670-406c-b7dc-3e713cd4b76a">D<xref linkend="sect_CID_3456" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37023b3b-7aa1-4850-9966-e670e2782f1d">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8aaa0411-0b17-42db-9ddf-2de1d89caf20">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_379bf108-f79d-432b-9333-5c3f9abd3456">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_129301b8-da7d-497e-a502-a2f237a79c8c">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f325246f-e433-4ad9-b737-b2cffb0875be">D<xref linkend="sect_TID_3219" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_03d84d8e-ef6b-4216-a395-a9738c953f70">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_58e565f3-df0d-4a6f-995d-bbd54170f898">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a11c860-6548-446f-88e0-6f7b21fb1b88"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d86b800-9c22-48ab-93aa-a4bf38c013d2"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7ec8a44-1d06-4f29-bf41-ee04bffb91ad">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11888156-af9e-4920-bf1a-80b1f73f9c61">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_95737a9d-4b74-4cc4-9dbb-42f9d39457e2">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e397584-eb24-4fc8-86f2-2cf801e4d6b8">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a6fcbbf-a26f-4679-b932-f49f802c0591">D<xref linkend="sect_TID_3218" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_888ea894-82c2-40dc-b663-20d9c776b3fe">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_535667ef-9f70-4336-b004-fb6dd84df5c8">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e88667c-6a70-49ab-b02f-610437bca08b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c2b46db6-ceeb-4e9b-9767-af12dd3e9002"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_133b22ba-462d-4949-bea6-7439c8fff61c">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bca19e9a-d539-4061-9e1c-4aa567b689e7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87cd6c0b-e0e3-4d30-bc11-96ff9f51806e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_832bc982-fcc0-4961-b744-671c57c2871b">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3829d5a3-734c-4d18-90f0-8a06f5dbbf12"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b4289948-60b3-473f-b7f7-dce793110697">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_be0bf032-8df2-4bcb-acd7-2b862569c23b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99f43b48-0789-48b1-8c17-5ba4418c7ec1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c89fb6a-8b3c-4b44-b075-6ebe2ae7f0fe"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_eca350d1-9a27-4385-9892-302d2950b071">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a4a3753-2870-4f1b-83e5-542f1be71e3b">Row 7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa2e1dc3-7e97-4023-b54b-33a868a460b4">Secondary Capture image with obstruction analysis contour. No purpose of reference is specified.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3218" status="3" xml:id="sect_TID_3218">
                <title>Position in Arterial Segment</title>
                <para xml:id="para_4b2e3d7c-7e97-4bf2-b1d1-b68d46731a13">The Position in Arterial Segment Template consists of the position Content Items common for the Angiographic Lesion Analysis and Sub-Segmental Data.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_395ff09a-4290-42e8-b220-d0e78ff0d614">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_c17c0631-4e28-4f00-9624-b4b5800e16e3">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_21e577cb-0c77-40a5-8226-d0f63cacf8e7">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3218" rules="all" xml:id="table_TID_3218">
                    <caption>Position in Arterial Segment</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_edb89171-797f-4868-9d13-2a64e1c52370"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7ce96603-a51d-4a69-bb61-0278b8ce101b">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7f5d2b6f-3f9c-4e50-9ea6-f4897acd0927">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_50535b2c-8487-4464-b29a-ca8f2a98c78f">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_21567ef0-38e7-453f-be22-444c94e914f6">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b166a290-3715-4ad8-b719-e91708d8234a">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4e5aaa7f-4a4e-49c0-85e7-dacc4f01b01e">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_744acb61-a906-473c-9a3a-72b321911a5e">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8943f365-4c65-4417-ba94-63c8b03e4130">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c63d0dd-1798-4b87-85c3-e640f82bc39f">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5264571c-79cd-46cd-86b0-bafb43a7d66b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee35d83f-b84a-4433-b0a4-f3c093562f2d">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7daf69be-9d2c-4f9a-8bb2-0cb00c74176a">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a47d8a8d-b282-464c-ace2-0435811a006f">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d47a92b2-6170-418b-8f04-fb90166e406e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_13746bbc-6f25-40c8-add2-c0b5d316f8f8">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03832df0-52c1-4373-8e02-2267a76f549d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f46d9049-df75-469a-8220-8f65dde48954">$Measurement = EV <link linkend="DCM_122528" xrefstyle="select: nopage">(122528, DCM, "Position of Proximal Border")</link>
                                </para>
                                <para xml:id="para_767db095-64df-4974-aa4d-a7e25e2c7325">$Units = DT (mm, UCUM, "mm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b4c99f0-a799-4422-b9c0-ad8e701d4478">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7cd47982-ea4f-46ce-93b8-0a6e758086df"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fbfe545f-be49-46e3-8b58-8f5204c6883c">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd0047f8-bc50-4cbe-afa0-48171bf79e26">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_075499e0-8898-41ad-8fdd-5568ffde9f3e">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e868a5b5-1fd6-46f6-b8a1-4c2b9bc36507">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ee75b17d-a677-4300-bf3f-31cce6bfa500">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83c170d7-da88-4e0d-b55d-079e6d9d6452"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c0ae5e6-9b67-4cbc-af76-7267db269901">$Measurement = EV <link linkend="DCM_122529" xrefstyle="select: nopage">(122529, DCM, "Position of Distal Border")</link>
                                </para>
                                <para xml:id="para_5b4d6933-b52b-4bd0-b062-6ffee60a719a">$Units = DT (mm, UCUM, "mm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d719fcfa-b9e0-4cc0-8902-4eab67bbec99">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_726c66ea-5981-411f-9be9-9fb9d55ea83e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_125f0495-836f-4fd1-b47e-7b1cc68e3ca4">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_852dbf2c-fb3e-43bc-82c3-fe5ee32f08a4">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ee78730-c49f-496b-afb3-aac6f4c9eb9e">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_80eaa804-30e0-48ab-89d6-259d6337d6cb">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_515d51e9-1b4d-41ff-958c-b3bd8bfd9927">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5dceee1-bb1d-4d0d-8ed9-8d65086f2d4d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b30d074d-7f18-4ee0-b75e-11cf10f9ed7a">$Measurement = EV <link linkend="DCM_122382" xrefstyle="select: nopage">(122382, DCM, "Site of Luminal Minimum")</link>
                                </para>
                                <para xml:id="para_9b70ce83-4234-454e-8877-e1f8e47b733b">$Units = DT (mm, UCUM, "mm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0912c6f-3de8-408f-a58c-5bd5dd3d6c12">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2480cf67-374b-46f0-8f1d-e6e1ca097b9f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5cb2fb70-ed2e-4a77-a369-d3a241121cc9">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36a919f4-c069-491d-bc28-78ac8e6240b7">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02808df8-f12f-427c-9030-beb0fd58df37">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_26268f11-0869-4804-bde0-0595eed69903">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b16b4a92-16d3-4ae4-a22a-9132b9047f0e">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bbb45a4e-0cbf-472e-89dc-7385d0159389"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91c1fe4c-fc3f-4221-835b-0fe3d3938f51">$Measurement = EV <link linkend="DCM_122516" xrefstyle="select: nopage">(122516, DCM, "Site of Luminal Maximum")</link>
                                </para>
                                <para xml:id="para_24d88dcd-e437-4293-a7bf-d118bef65807">$Units = DT (mm, UCUM, "mm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b38e28df-61bf-431e-a7ca-66a077eb783b">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ec3e289-c781-49ca-9a6e-7b02dc8cf748"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ac9f378-97a6-4a34-bbf4-ecd5205a0f6a">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_089e037b-9131-4d69-87f1-c5d6f5d81750">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d4d4811-f6ef-402b-928a-238b1203cb1d">EV <link linkend="DCM_122528" xrefstyle="select: nopage">(122528, DCM, "Position of Proximal Border")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c3677b8f-bf8f-49ae-9b7a-9ede61e6d0b2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_019e74d5-199f-4399-b655-46af38cc66d2">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d2ff3559-be31-4ece-9b05-bb1211ddcd0a">IFF <xref linkend="sect_TID_3214" xrefstyle="select: labelnumber quotedtitle nopage"/> Row 14 is present</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fee5e84c-4a9b-47f1-a20b-f41fb1b3b761">UNITS = DT ({pixels}, UCUM, "pixels")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c68ca1a7-c6ae-4d5a-b126-0946c72a26ec">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b611b784-a519-4634-a6e2-fd79718f8857"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85fcdf34-f170-493a-b9c8-580940c630e5">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_444ef744-89bc-4a80-bf96-16e0a47bf4f2">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a48ce52-64f2-4f06-9593-47c884b9b432">EV <link linkend="DCM_122529" xrefstyle="select: nopage">(122529, DCM, "Position of Distal Border")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c5ec542d-05cd-4789-87ed-e06404ecfe03">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9fa92b81-18aa-4fae-9978-26f4c73467a4">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3572021c-6f59-4201-8910-c98a79f0d069">IFF <xref linkend="sect_TID_3214" xrefstyle="select: labelnumber quotedtitle nopage"/> Row 14 is present</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29954fb3-8719-408e-9d2f-385ea381f05d">UNITS = DT ({pixels}, UCUM, "pixels")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ab5affe-17e6-4981-b124-fcaafc7b795b">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4cc8135a-2905-4143-90f3-3a328f33ac57"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b9efff2-ce98-41fa-b87d-0820f276a558">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3b85605-e21d-4aa0-b462-32ffce815a70">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a1736a3-c5f4-4d64-8e7b-f327c8d0c898">EV <link linkend="DCM_122382" xrefstyle="select: nopage">(122382, DCM, "Site of Luminal Minimum")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3118afc6-4a32-4732-9221-3468c0cca34a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fd543aea-ab6f-4393-9189-111c5758ef12">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_322f4c2a-7dc0-4580-a6b4-1da5676098ee">IFF <xref linkend="sect_TID_3214" xrefstyle="select: labelnumber quotedtitle nopage"/> Row 14 is present</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22ff00db-28ca-4dc4-9fe2-790e94b8c0b5">UNITS = DT ({pixels}, UCUM, "pixels")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59ea0c60-c687-4fe7-9386-2a9bb701b0f4">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c6c4353-56e1-4322-b3d3-05fca6634913"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_466b4307-4860-4c65-8175-723283a7419b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35d9a49b-d8fd-43af-b127-776c4f4998b2">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f88c70be-9ae0-43ec-87c4-7b338ca0da04">EV <link linkend="DCM_122516" xrefstyle="select: nopage">(122516, DCM, "Site of Luminal Maximum")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2fbc0df1-313f-4f6a-9148-81b94214ae4f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c9995c8f-923f-4fcc-9a4d-31db5610502b">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86b4e152-c3e6-4e74-a9d4-59fcc56456f6">IFF <xref linkend="sect_TID_3214" xrefstyle="select: labelnumber quotedtitle nopage"/> Row 14 is present</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00726b95-dcd6-413a-a882-01e9e3e0644f">UNITS = DT ({pixels}, UCUM, "pixels")</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_f99798cb-3064-4c9f-a706-8feb6fcddf14">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec01e41a-24a0-4940-9916-b73493dc959b">Rows 1, 2, 3, 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_77850d79-c06c-464a-b1d4-3279a6098e08">Positions are relative to the midpoint of the first left and right contour points and measured along the midline of the left and right contour</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad66f5f9-1583-4149-aaa0-07406107fa95">Rows 5, 6, 7, 8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0194386b-cf8c-4bb4-8ef6-597accab3122">The positions are relative to the measurement locations of the Diameter Graph of <xref linkend="sect_TID_3214" xrefstyle="select: labelnumber quotedtitle nopage"/> Row 14.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3219" status="3" xml:id="sect_TID_3219">
                <title>Segment Values</title>
                <para xml:id="para_5fb1cc83-8da0-4973-ad47-77fe8e16c6fa">The Segment Values Template consists of Content Items providing quantitative arterial analysis measurements for a total analyzed segment or sub segment.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_9aa8a32a-8ebb-4de8-8e95-5930e4a4f1d6">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_de75b054-99ee-4013-bfc3-6667356f9b43">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_faffa767-8e6b-42e6-91df-eff1910683c2">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3219" rules="all" xml:id="table_TID_3219">
                    <caption>Segment Values</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ccc5bb35-49d8-45c1-b6bd-989f40d3915f"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fa625e8e-dbff-4099-a718-48984a1ecc79">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ad33b247-c0a5-4529-a4ae-dc645ce531e7">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cddb2201-a7a6-4f71-80d5-9374dd146018">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_50b94970-a1f1-4849-a654-42873d31c0f4">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4ae53186-4013-40d6-a636-f608626003f6">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dd5f9e1a-fe6c-4732-8a1f-34948242cae5">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4b6994fa-fc45-4ef4-958a-16c132ebdb52">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_024459f3-a438-415b-bd74-177933ca8f7b">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b160c643-c554-4bba-992c-492a0f15daa5">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fcc0940d-9e78-42f6-9154-415cc2f7734e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bad9f0e6-a5f1-43ac-9f4d-20ca5805044a">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e751ec1b-6502-41fa-973c-e9e3d476d74b">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9eeff61-b9cc-46d7-a8a3-d50140e0b860">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bce81542-2d91-42bf-b9d7-92d36c84e948">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_02a33fee-8d89-49a6-ba4d-585607e632c1">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c41ae7e0-2c9a-4745-b207-67a8d48f3452"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96a38e8f-a4ef-4ed4-a835-b6026d4305c1">$Measurement = EV <link linkend="DCM_122510" xrefstyle="select: nopage">(122510, DCM, "Length Luminal Segment")</link>
                                </para>
                                <para xml:id="para_5fc27fbe-7887-4918-8d0d-21e45607d7fa">$Units = DT (mm, UCUM, "mm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0261601c-087c-4829-8f7d-11fc6f7d5194">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc4880c4-7c95-4272-afa1-d00ca1010942"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_218a6366-340a-473d-bf83-fd5251e9602e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c2be9e0e-b89c-4bba-998e-022d1529c956">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4bb6d71-ad79-4731-9815-e578dd5f0884">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_34c4233c-aa00-4454-b462-f04aa97d0170">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9723cc3f-14c5-4cc0-9161-929d80dc73d7">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f8b2780-6b00-4691-b848-fcc0a6fdf6e6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f073dc8-0ce7-4b80-b40b-ae7c7ba2e1ce">$Measurement = EV <link xl:href="http://snomed.info/id/397413000" xl:show="new">(397413000, SCT, "Vessel Luminal Diameter")</link>
                                </para>
                                <para xml:id="para_4b7211a6-ffd6-4d78-9fc3-f9e46b0294e0">$Derivation = EV <link xl:href="http://snomed.info/id/255605001" xl:show="new">(255605001, SCT, "Minimum")</link>
                                </para>
                                <para xml:id="para_e0760edf-fa1b-4f9d-992c-d85cb7fe3ac9">$Units = DT (mm, UCUM, "mm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69eadd9d-30e6-4692-a723-81a3062964d4">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21161e86-0042-49fc-af77-e75b28f2de16"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4873d175-4895-4af9-82c1-19d77ed66ee0">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0cd1da93-3022-40c0-a3a3-3e4a5a754526">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b38868ac-d406-4af2-8460-854c16e4ac58">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_680dbd1d-41ff-4d3d-af30-83fec60dd592">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_da16ac4b-3458-4b1a-beb1-6e8fe82692f0">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04a381c0-1a94-47bb-bd95-5a6c1059c1ec"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ecd4cede-7354-4199-ad14-5e78986519f5">$Measurement = EV <link xl:href="http://snomed.info/id/397413000" xl:show="new">(397413000, SCT, "Vessel Luminal Diameter")</link>
                                </para>
                                <para xml:id="para_bacef92a-88fa-4bd5-8d2b-b87966d83290">$Derivation = EV <link xl:href="http://snomed.info/id/56851009" xl:show="new">(56851009, SCT, "Maximum")</link>
                                </para>
                                <para xml:id="para_e0a271d6-7b56-4557-b347-90c446ad9a93">$Units = DT (mm, UCUM, "mm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7086e979-69a2-4ef3-bb3e-1bee3efad306">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2bdfd26b-e98f-4629-94fa-68056a3e3ca2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a7a6300-68e1-484c-a543-136988cf4bd3">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1dff5e39-55c5-4a25-ba97-ec48e3caecd1">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2071ffd4-bce2-4637-8396-b4333dd69db5">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9e3495ea-02c7-4b2d-8658-bf6888803175">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_26b06796-a83e-4f2b-a59c-8ee353b7d3c4">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_021352a5-5f1c-42a2-91c6-348b22c14ca8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4521286f-1629-47c3-a97e-ba66d7e937d7">$Measurement = EV <link xl:href="http://snomed.info/id/397413000" xl:show="new">(397413000, SCT, "Vessel Luminal Diameter")</link>
                                </para>
                                <para xml:id="para_2ec3b4a2-216c-40c7-898e-af6c75c5ae9e">$Derivation = EV <link xl:href="http://snomed.info/id/373098007" xl:show="new">(373098007, SCT, "Mean")</link>
                                </para>
                                <para xml:id="para_1dbc044c-95c6-4246-a9ef-9e508006b530">$Units = DT (mm, UCUM, "mm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2ddd61a-f6a8-41e0-9865-e37c8a87bbd1">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf0ab66b-0642-49d6-b996-f05bec3417a0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59ff9078-d902-4f1f-afbb-453d54ba3dc0">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb969aa2-6431-4da0-9a85-77ae85829fa2">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8063d456-232b-4a01-83ea-7200a79be06e">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6cbfbf5a-b6d6-4783-9921-de0b460249e9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b8367365-ab85-45f4-9d71-041bdfed5e6c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22b0f74b-f8ce-4490-af68-61c194fc5930"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae08e197-0146-45d1-8f2b-e46acf94730e">$Measurement = EV <link xl:href="http://snomed.info/id/397413000" xl:show="new">(397413000, SCT, "Vessel Luminal Diameter")</link>
                                </para>
                                <para xml:id="para_8f385c44-154c-4e34-be94-e43079741ab8">$Derivation = EV <link xl:href="http://snomed.info/id/386136009" xl:show="new">(386136009, SCT, "Standard Deviation")</link>
                                </para>
                                <para xml:id="para_831ed67d-da06-47ed-b072-5f8c5a72055a">$Units = DT (mm, UCUM, "mm")</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_72c4be0c-da07-40f4-a65e-c14246d5578d">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a4f0d48-3997-442a-845c-450bb48a6bdc">Row 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_edb36f3b-0a1d-4acc-8170-a8f56dd9af2b">Measured along the midline of the left and right contour.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
        </section>
        <section label="IVUS Report Templates" status="2" xml:id="sect_IVUSReportTemplates">
            <title/>
            <para xml:id="para_3d9aecf6-aff5-4455-84f2-cf0c82102c3f">The Templates that comprise the IVUS Report within the Evidence Report IOD are interconnected as shown in <xref linkend="figure_A-5" xrefstyle="select: label nopage"/>.</para>
            <para xml:id="para_6549d032-4e17-4ac7-add3-bacbc3377ccf">
                <figure label="A-5" pgwide="1" xml:id="figure_A-5">
                    <title>IVUS Report Template Hierarchy</title>
                    <mediaobject>
                        <imageobject>
                            <imagedata fileref="figures/PS3.16_A-5.svg"/>
                        </imageobject>
                    </mediaobject>
                </figure>
            </para>
            <section label="TID 3250" status="3" xml:id="sect_TID_3250">
                <title>IVUS Report</title>
                <para xml:id="para_2c869266-9786-4e9e-bab0-f854a4594a6d">The IVUS Report Template is the root structure for the representation of IVUS measurements acquired during a catheterization procedure.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f0bab094-df93-4b31-bf33-e0159722f3b8">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_0a598a4f-8171-42ee-95eb-45d45d174ecd">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4058d3de-43c9-4efd-a8e3-76faca70cee3">
                                <emphasis role="bold">Yes</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3250" rules="all" xml:id="table_TID_3250">
                    <caption>IVUS Report</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1c48316c-5578-4caa-ada5-a5f7c99145a1"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5badee9f-fb23-4d01-971c-d3cef7672317">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_72a39213-e154-40e3-936f-40c7c8fb1b67">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f18b5bb-6957-46a5-8a59-b35167b1f781">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_355cb973-c523-4cf3-be15-35d256ee8ac2">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a6b1b649-bd98-4d93-b621-25b617620bc1">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7a473bb6-7577-476f-bce1-c5947e2eebe8">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2fbbf1d4-1523-4d83-bc3c-c849d0f0ede1">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_84baf92c-f1f5-44b9-9d53-688b078ff650">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7bb60c50-6e19-4369-8e35-1105d259fa80">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e87c706-53c2-4200-bc0c-52f8322c1c4d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0536f561-115d-44e4-bd83-396de1f2a4b1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a35000a7-fd8e-4fa6-bfc6-b91f2c9e12d1">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab3179a8-8403-4875-9b8b-2d7e034d66b3">EV <link linkend="DCM_122325" xrefstyle="select: nopage">(122325, DCM, "IVUS Report")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3ccc0bd9-a5c5-4250-9546-5123a2d3e7e0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_04657db0-0af6-42bd-98d5-00bd26707ee7">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b25a2ef7-ccbe-4346-b649-3545ce4233e0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4982d8fd-f812-448b-bfa6-f493a14add5e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d791ff1a-c8e9-4002-a3e1-6c653013bde0">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea1ac403-e2d0-4ea5-a125-86e086751889">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_571c15c3-88a7-4eeb-a722-ad5068519113">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d6962c50-c87d-4f0d-8144-33dda12e83a1">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0ed9f10-f576-4d6d-a2f2-7bc229f9ddd1">D<xref linkend="sect_TID_1204" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_30f7abfd-dfc1-4061-97c0-aa6c1f58d4fc">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2c1e510b-9bac-4fd8-abd1-40d16badb18b">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d2cc2dbd-bed6-4781-8d36-e3bf86d73c04"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bfd36f3e-8ab6-4a19-8cb4-502b1faa110e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_217b5484-0a1e-4cf2-bd6e-fcb1bd5a3df1">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b91f36c2-fc1e-4fb5-9742-3ee1f3e5fa84">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_abfc48df-4634-4deb-87fa-9402bb2e5dd0">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d099d3b-6318-49fb-847e-fa031f97b217">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d01777f-a6f2-460f-ba14-fbd73b1b3a46">D<xref linkend="sect_TID_1002" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_957f0b51-f2e3-42a4-a4dd-8bb9de457197">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_521519b3-81c8-4575-a8a9-3a803c9a3f83">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2210ff56-95bf-4ea3-a077-402a4965bc40"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_803c9451-c83f-4459-bfe4-ff3e1e384647"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca2215fb-8aa8-4085-847d-2f0378ae80d9">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36cf8386-a416-4978-9315-3141b92336a4">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b824c2d-201e-4a43-879b-eb66ef4eda69"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8979e2ba-7802-4063-8d14-7abce6952e9d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2cec38c5-9e95-42ff-a682-a92e1322d4df">D<xref linkend="sect_TID_3601" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8bcc09a0-35b5-497a-a254-d1a8d8ce36c3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_55c3865a-55ec-453e-83b5-cd2093ce7b9b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4bdd79f1-330f-4cf8-88b1-16cf941536b5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_acfe7f52-c9cd-4245-8489-fca26a804579"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a70a4903-8529-4cb2-92ca-be92e9db66a6">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04904111-04a2-493f-919d-950d07daa16b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61083778-bf1f-4097-8ca6-552573d5db80">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c3bb528-e116-4841-8388-a3cd47166010">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_475dd147-335b-4152-bada-f99ef1bb9950">D<xref linkend="sect_TID_3602" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2730b088-816c-4bcc-9cad-28192236baa5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4bf25bdf-2d19-4d49-82a8-760d53fc49fe">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5503849e-79cd-41c5-83e4-a089039af908"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1cd65a81-33a1-4f39-8fb9-a1ca84f599b4"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_984df026-89b3-4ced-bbf2-b0d94e765654">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e3d1f18-f224-49e9-beb5-024828f188dd">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_caf4a37e-0489-4aa0-af22-21acce44238b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_14065f86-0883-49f5-8ae5-a52d21ec98e1">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc9bc0bd-328e-4e84-af49-2117f8b218aa">EV <link linkend="DCM_111028" xrefstyle="select: nopage">(111028, DCM, "Image Library")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a217e156-593d-4b54-b4e2-e9b6c6e59cdc">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_49b67d88-4b3e-48d9-ba35-17514ddf5770">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_582393cb-8e50-4b61-919b-f996fdcc355d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31a3e03c-b318-45ed-a828-834fda75d10e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f986cb50-c84f-44ad-b90d-e1fd874cd4db">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75646271-5623-4a43-8237-a344afcb1661">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2be83ae-abb5-4cfd-9173-141f705eb10f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97ab9f76-af20-45f6-b975-49ed9861fa78">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63736009-9967-4853-8227-125e1aee427a"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4efeb1bb-8141-4015-ae16-7c91e72c29be">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8b92557e-ab12-4800-8752-ca6d5c54acd6">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f57db27-c877-461f-b3ca-150338d25151"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d18fc820-ab5f-45a8-9549-f47f0cc59b48"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03456cd2-b2c7-4f62-a53e-3f2443e8e41f">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b612002-7e53-4686-a6cc-cfa7f2daffbc">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_01ee91fe-1cd8-4d1d-912e-d4f0fa64fab0">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b6cd4f9-7cf4-4791-b741-8e9036469d9e">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c05f8f9-cb36-4e29-a132-c74ac0bf9f1a">D<xref linkend="sect_TID_3251" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0f7356d5-4bf3-4506-8771-0960cd23fa92">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4af6b77b-2738-4fa6-baef-ff467bcca09e">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0e6fe5b-4958-49e5-904e-2bd513adae45"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_934221af-debf-4328-ad51-ef33e0665966"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_d2311a2a-888c-4383-a131-7716ee8efba4">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd232ef1-f658-44b6-afa3-0b471bfb7fed">Row 7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1f0ec938-5271-49d5-8920-05067071bc2f">No purpose of reference is specified.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3251" status="3" xml:id="sect_TID_3251">
                <title>IVUS Vessel</title>
                <para xml:id="para_f49c717d-7b63-42dc-bb81-9598a34c4259">The IVUS Vessel Template provides a structure for grouping one or more lesions analyzed and/or treated during a single phase of a catheterization procedure, according to vessel (or arterial location).</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_1f1c6519-3c77-4556-bac9-ebd99ea8872a">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_bdcfb0fe-bcde-4bb7-b4b5-44e8d2dc06dc">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_998218e3-4b5c-4451-8e89-1d155f8bc767">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3251" rules="all" xml:id="table_TID_3251">
                    <caption>IVUS Vessel</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5bdf24da-1e78-4962-9950-0b2ac0dd4a74"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f8d43e69-4e7f-4f7a-afaf-ad43dd17fd51">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2e572bea-28af-482a-be63-9a4088850628">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_81d8b3cd-e8d5-4e94-b8c7-0b595b5632f4">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_985fb8e0-fd7b-4fc6-b1c9-4d2ea13628df">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fe52e0ac-a67a-48e9-9775-5eeb389f52cd">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3eec9f07-dc26-4945-bda6-884f269b069d">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_376a8bf8-7a1e-493f-b092-d528cad56edb">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ef2cbc3d-f608-4f47-b0e7-85070fb45856">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_551ecea1-fa7c-4a02-9127-38d4557624b7">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fba15ed0-2280-416f-84f0-fa99e1db97d7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0cbf1b0f-e552-4f88-b0dc-b62e35fa069a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3261dc2d-c777-44b3-9b8b-990463d18244">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f36e1dad-140b-4520-be52-72d67e890de6">EV <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7a0bfb53-d73b-45c8-a6b1-2948529fee4a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_da5d97bd-14fc-4950-ae68-e3944bb51f6a">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f819ab4b-8b9a-4693-83c2-083889803264"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cbfb55e8-c22d-43dc-b308-30d4e05c57d6"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1cab3c5-0db0-40ba-98bb-69728867c1ad">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_704e3776-3a8d-4044-a339-833c6f25ff5c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74abd588-11dc-42d1-bbbf-00f05f0d63df">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_143eda43-2f79-4eae-886d-feedb6cdf5ef">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9936f995-fd7b-4a28-ac29-32671e58a333">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0011ea9c-7e2d-4c69-80fc-ac58d8f289f5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_64016657-eaec-4e6f-a901-838c357e1187">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7672fcaf-ca01-4a16-91d0-d61d549fc8d2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_352317ef-87c1-4f95-a66b-edc33647f4d4">D<xref linkend="sect_CID_3604" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f98799b-79ac-4df6-9d63-4c51c99aa8ce">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd214584-d269-40b6-bb98-c6f16c46351e">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a528a2b-3db4-4b8e-9b21-36e032454299">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3d85204-1166-4692-94d1-7946d2ed4ad8">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fed5b10b-f830-4f60-a728-acb3ab0bc59a">EV <link xl:href="http://snomed.info/id/106233006" xl:show="new">(106233006, SCT, "Topographical modifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69dcc095-651f-433f-a08d-3fedd6a7304c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_23b0f4b0-7f2f-4e3a-ac88-8dd4ee8b3cd3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1eac0470-156e-448a-89f0-febee5550f3c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f686408c-d00f-4d55-b5ef-cc46dde2020b">D<xref linkend="sect_CID_3019" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37a416d0-e355-4787-b437-a9cee0668092">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b85bba4e-2864-41ee-bcfc-9f0832771b2c">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0ff5681-05f5-4777-b4c6-015a0895bd44">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58b7e9a7-3cbe-4667-93a7-b95fa0a23798">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e4e7fe7-28ba-46c4-a7ab-5bcadcb552c2">EV <link xl:href="http://snomed.info/id/272741003" xl:show="new">(272741003, SCT, "Laterality")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c04cc7cc-4a9f-4426-9f66-47c2c17ca2c2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_27940d09-bbf4-41f0-a2bc-a6885e3b1f21">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_858d643e-e364-4e60-be0e-90355a4ac4b5">IFF anatomy has laterality</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5c8149d-24f1-4214-8f95-d60edb8d0f2d">D<xref linkend="sect_CID_244" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4614fe9-28c6-48cd-8e82-1eb60f8df6af">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af236810-7f31-4423-bcc8-55a21d9ba187">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_610b5ad8-6a0c-45c1-800d-883b6067bad6">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5d7d27d-8d26-47e7-be6d-babf2a108f2b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3da9ff9b-17f4-4f5e-b22b-f6d6c55848b0">EV <link xl:href="http://snomed.info/id/129085009" xl:show="new">(129085009, SCT, "Catheterization Procedure Phase")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_27c8058f-7af4-4013-88ec-dbfd166f3587">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f519bfdb-4230-454d-a45b-eae7365bcff2">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5149b9a6-f278-46c2-a952-c3ae1ef748ec"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4142b7fb-3aac-4be3-a3c3-e88c4100f347">D<xref linkend="sect_CID_3480" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bfb09cf6-82d0-4e4e-be0f-8a3308fcbb51">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5a19b86-bdea-4521-a2dd-e52c2291bbb0">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ae10476-bfc6-466e-a8dc-f88bf110e15a">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a350693-dbba-439d-9fed-f4fc746e0a08">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5221ceba-2bed-4fd9-a3eb-684e05fbcdbc">EV <link linkend="DCM_122134" xrefstyle="select: nopage">(122134, DCM, "Vessel Morphology")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9baa1b0d-d9d3-414d-a24a-c6f1906268c7">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f8f1572e-bb6f-4bfa-ac0b-6bf4f9ef3024">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_583ad2e8-1e92-4a1c-827d-4c5021f92787"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f707ebbe-b349-4635-80a4-34943695f498">
                                    <xref linkend="sect_CID_3712" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b3a3b86-084e-4379-ba05-65995fb80392">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a3b26ae-4975-4844-855d-1cde6cd53c84">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de019784-37fe-429a-a0be-9ade9a805262">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b053de3-adf5-433c-9341-6c698b45bef3">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_711e09e2-6e33-45d1-8ba7-01079de41b65">D<xref linkend="sect_TID_3819" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_72c27821-f7a7-4aa9-8cd3-954ebc4ecf75">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9cd890ff-2e3b-4087-852f-b5af73c28bd5">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25698305-e7cb-438b-a3fd-0fe8fcbff570"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_194979c6-3e4d-433a-9374-9f2cd553dddf"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7060dc18-c6f8-414a-9920-5b68d19f1155">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c85d23e2-f603-409e-b407-d19412f634e0">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e83993a-9dd1-4627-8e33-1be71bd0c902">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9793dabb-a47b-446b-8f3a-8df0b7554e0d">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5202bc7f-1f7d-4620-8fa3-4ed689a3d9a7">EV (115, NCDR [2.0b], "Dissection in segment")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_01c7bef0-7b13-424a-bec2-2879bd269c77">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_40b8628f-2e56-4605-9cbd-020cbe26414e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ccc88d53-9bd9-49c7-8693-91faf590bbda"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_64fa45d9-e5e1-45d3-a49b-60d5d396b63a">D<xref linkend="sect_CID_230" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5b0fbe1-3eed-4ca5-a832-4fa748e495b5">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63ba7273-1f54-4342-963f-4d1c5a5abe9f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df637480-00a8-4c90-bbdb-326c6d6fc8cc">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f26e9f2b-f428-4fc9-80fb-fb7ca2d3fcb6">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0fe68b1-9e5e-422b-8f9d-b7aef1133a86">D<xref linkend="sect_TID_3252" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a27ccccf-6ab6-43dc-af9f-061308d1ced6">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1d133652-ea70-4f6a-a1c4-d6ccff678964">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a508faaa-f274-4e82-8258-3b6a9cc593e2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_47bf6ef1-58d6-4cf7-9858-6190e1c5a26c"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3252" status="3" xml:id="sect_TID_3252">
                <title>IVUS Lesion</title>
                <para xml:id="para_28f6c01b-ade0-4bb4-95a0-d50e8eb24cb6">The IVUS Lesion Template provides a structure for grouping measurements and observations made on a single lesion during an Intravascular Ultrasound Procedure.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_43b86209-4dd0-4151-b74c-897e19553035">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_5c56918b-d3c1-4e48-9d28-2dbb9a522b5a">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_63eeafb7-940c-4ad7-a2c1-99b4a094999c">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3252" rules="all" xml:id="table_TID_3252">
                    <caption>IVUS Lesion</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bf51ad62-66f9-47d1-a6ff-4c2973444f5c"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c3690da-4743-4dc3-8442-6fb807ccff91">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c19a9568-f714-4451-a8ad-aebd56a5b973">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f6ad0c66-621c-4fe1-b336-2a3f76e5e245">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_14e0e5fd-cc73-446b-a936-5a8e475a21aa">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8fe879e8-2b83-4656-85a9-1434f09c929b">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c7bcbcc9-a759-4b5f-bb8e-50bea8a2bf00">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_054dbfe0-de9e-4e46-b986-19033f6f2ac6">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1bef9ebd-3dc9-4834-827f-59d200aa9ed6">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2e26c84-f13f-42e9-8cf2-9ae1be601976">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22c965b3-68a2-4340-aa18-58142ec75749"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5b90d54-280b-4289-949e-2d73498cd64b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d11a004e-6b44-4dbf-bbf6-2fbc85be4bd8">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0994c9d1-56c6-4494-a337-3eb985cdf6ea">EV <link xl:href="http://snomed.info/id/300577008" xl:show="new">(300577008, SCT, "Lesion Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c2cc36ce-12ba-4ca5-bd54-7d1fd2fd1102">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bdb5034c-b2fc-4365-b06e-aa368da5ea3a">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ac68a40-e0ac-4f03-8d2c-dc2464431cba"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79f3aafc-da29-485b-9c3c-678a7c5a61e8"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc8feab2-61d7-468c-ad8b-c624c02d9c1b">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38b6f76f-711c-4039-9980-b9751be9bd7f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1c61c1e-fa1a-4d23-9f50-54cf40ad4b90">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3692d534-a342-40c5-9f5b-97dd5ff51072">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ff51385-3538-4ab3-a378-08afbdd15c08">EV <link linkend="DCM_121151" xrefstyle="select: nopage">(121151, DCM, "Lesion Identifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_00d5f6fb-e58d-4b51-9594-23e5a25635c8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c054da7f-311d-4b5b-9471-105819aec85b">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_044b46f6-6ee1-4735-86cb-b59a0647a11a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2f55949-06d9-4b27-8a7f-e5b2c63122c1">Up to 3 numeric characters</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7dd52d1-d874-40e7-bd91-3d747d8bf13f">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b8c0e342-f07d-4aec-b52b-5bf19701587f">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6a98732-a0b5-4c9b-95dc-d86fab24668c">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2faddfbb-9144-436c-b07e-68d272523557">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5337f8a6-0202-47e9-93eb-0667410b7610">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_535a85a6-ef58-4868-aef4-ee6af52e48fc">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6765c830-4fa2-41ba-9dc8-cbfd6bdeb6c4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c88249fd-cc58-473e-acd4-c4696d58a672"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bfae75f0-bbd6-4a46-9a0a-94bce114d9ff">D<xref linkend="sect_CID_3604" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1ead4d9-d77e-4a61-b3ac-5e070d1c8dc3">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0dad6461-cd7c-4ead-a77c-bf9ccf24bba7">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b004991a-0c3b-4968-982b-92cd4c47c8f9">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39992c68-de82-494c-96f0-50c4b4a80f2b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9ad3d9a-9878-4eb1-88a3-efb8c2d0ef90">EV <link xl:href="http://snomed.info/id/106233006" xl:show="new">(106233006, SCT, "Topographical modifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0733ba6b-aabf-4872-a60a-6670d2200768">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6e799da2-aa45-45d3-9452-90a012e1d33d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9380ae23-afa6-4f53-b79a-7ac90aceafd1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_105bb7b7-4495-4bbd-9cee-36d07b3f1ec7">D<xref linkend="sect_CID_3019" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d614343e-66b6-4c7b-8823-007d0c0a57e9">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1f1508d9-b023-4126-875f-566de83575cb">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f59d101-6c99-4f86-9ca0-8ca7ec33d8d8">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3ae2acf-aba7-451f-84da-69de98667987">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d7a1a35e-54a9-470b-ab80-5b12986c41c3">D<xref linkend="sect_TID_3107" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_05bd66d7-8065-4164-a9c4-571891eb6221">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d357df91-a674-424e-a307-cdca8cbc69db">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_031cced3-3a1c-43ea-a7db-3be358ec545e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e29fa83-008a-4ba2-b1ea-a9e052795ab1"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a1a3bf19-55df-4ba2-9ce4-7f8bab891b16">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f3b9e75-dfc3-48bf-a51c-5e249ec1fb14">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2e0fd56-c150-4acd-9268-4190363d830e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3199497-c06d-4106-9836-ca044df420f6">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1fab79c9-25c2-49ea-84fc-c704b4437ade">D<xref linkend="sect_TID_3253" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_81e91d75-d2f1-4618-b697-23cbe3733968">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f3f4f2a1-d5ed-419c-a2e9-520482b5ff15">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4faddf44-fd96-441e-bf05-16397e7fb017">One or both of Rows 6 &amp; 7 must be present</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f817359-3f73-42f6-b178-028595f52c87"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b250a469-83d7-4c58-b48e-cbfa26988aab">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1fca5225-e466-42bf-b474-e5f3641c8a38">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc950e75-65c0-4ffb-bf8f-7e313ea8d6fa">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9119010-61ea-4baa-90af-dc715a322752">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_084bea43-9321-4761-b67f-cbd4c9afe3c1">D<xref linkend="sect_TID_3254" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_311b73d7-b13c-4e3d-b40b-3085e2d028e1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_469bd9c8-b910-4761-a661-1570ba29ec07">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a459b5e2-59d2-4c46-acff-919bd8696910">One or both of Rows 6 &amp; 7 must be present</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b9dbc46-34cf-486f-a260-970c6bc0c415"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a616557b-8488-43e2-95b0-072e0ddde6d8">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e98890d4-7520-460c-b512-62f54ec4629c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f487febb-7d11-4651-be73-0134711e8a20">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae910e34-9bf8-4a26-898c-60c6a49dee0c">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_856a89e1-b06b-4f8b-8f04-8433ee19edd3">D<xref linkend="sect_TID_3819" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_48f75e69-b953-4da9-9461-08ef9b348331">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5deb9c04-53af-4dbd-baf9-7dd85d9f301e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d14386d-f401-4fa7-8a3e-23f21457e456"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6dac964-7a5d-4de3-b7db-9a0b68075ce4"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_bec42488-8b68-4b11-b148-dfcc5d2e0c1c">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left">
                                <para xml:id="para_9390e7e8-cab9-4a25-9c18-02018243b59f">Row 2</para>
                            </td>
                            <td align="left">
                                <para xml:id="para_d50b6abe-3aee-4d4b-b93c-7ff1eb318abe">Lesion Identifier is specified as a numeric text string in order to facilitate trans-coding to DICOM Attribute (0018,3105) Lesion Number and to formats for outcomes registries, such as the ACC National Cardiovascular Data Registry™.</para>
                                <note>
                                    <para xml:id="para_cfc84218-5485-4501-9514-952ac52b3391">Also see <xref linkend="sect_TID_3105" xrefstyle="select: labelnumber quotedtitle nopage"/>.</para>
                                </note>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left">
                                <para xml:id="para_e807c073-622d-4bb8-a1e0-045da9c40063">Row 3</para>
                            </td>
                            <td align="left">
                                <para xml:id="para_6c9e45a9-f6f5-4b7e-8c07-3fc5abda2b02">Finding site may span multiple segments with the proximal and distal extent specified by separate items. These may not be totally contained with the segment specified at the Vessel level.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3253" status="3" xml:id="sect_TID_3253">
                <title>IVUS Measurements</title>
                <para xml:id="para_4e1abae7-9e36-4c2f-83b4-4bcc60876026">The IVUS measurements Template groups together simple distance, area and angle measurements, along with derived measurements that made during an IVUS procedure. Refer to the " <emphasis role="italic">ACC Clinical Expert Consensus Document on Standards for Acquisition, measurement and Reporting of Intravascular Ultrasound Studies (IVUS) "</emphasis>for more information.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_92119cb2-6f35-4583-8513-68be97e50c8f">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_148ce957-7b7b-4d4a-88f7-c566d6a29a5b">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f5462dc6-ecab-4fac-9378-7e46ff77f492">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3253" rules="all" xml:id="table_TID_3253">
                    <caption>IVUS Measurements</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5e8f9335-e4d4-4328-83f9-6a53cee9fb76"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_072e3372-ec37-4d4f-a9fb-688ec837d560">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73be11bd-60d2-474d-83bb-d532f1fe7664">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2f6fe87f-d10f-42d1-8a4b-78c2d4107ab2">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0367bd84-9b27-4956-a150-8f591c856a04">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d0bb65ce-82b6-4eb5-885b-8e0cabeb1419">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_368584c4-df14-4f46-a05a-ed01c62b539f">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_45090d3c-9501-4c1b-aa12-ba8f60e1e756">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7ea58b23-b58b-45d9-b969-2486c4160714">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e1a4d1ba-7f69-4fab-966c-59147d9b1410">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f308ed55-44ba-4c14-8182-a7f53d62b5c1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_33c25ba7-d6e3-40d3-ad17-0a063d82b7cd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_56417617-0cee-4347-871d-4b76e2d4d24e">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_caba23f4-4140-4c10-adbd-025bc3174e68">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_28a3eee6-c4b0-4fb9-a357-3335504f1944">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_94b801f9-3f97-42ff-9278-c6bee734938d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59232350-8eab-46a0-b211-262daa4e1ef9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d122f576-7b77-4223-bd05-327e41353dbd">$Measurement = D<xref linkend="sect_CID_3481" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_d7122813-973e-4486-97f0-7bf3a863e2bb">$Units = EV (mm, UCUM, "mm")</para>
                                <para xml:id="para_f97d66ee-f315-430e-862b-18b70379cf3c">$Derivation = D<xref linkend="sect_CID_3488" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_6262621a-3660-4f1f-a709-7f689cd57d28">$TargetSite = B<xref linkend="sect_CID_3486" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_34e9dc2a-4901-41a2-846f-0531f504708b">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c0f73e6-c13a-402e-8a65-0beb27ff3a3b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25877e80-5f84-4d38-bcae-523b0ca32481"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30cc394e-a471-4f11-8394-9580c6a7dfe6">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81f7c9bd-4242-43e2-a8fb-9808c7a2b606">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_03a4798a-3f15-498a-95f0-27ce67f16483">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_15fac91f-40dd-4518-9103-9e44089512da">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2d5777a1-fc46-4ea2-b719-52ba8e4c2667"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6875cbae-4e9b-4525-97ed-5e53b6c3e166">$Measurement = D<xref linkend="sect_CID_3482" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_7b4a0254-8611-4059-96b7-8d41fe3e8de8">$Units = EV (mm2, UCUM, "mm2")</para>
                                <para xml:id="para_c4f6c2bd-09c2-4a70-b8fd-285b6f664173">$Derivation = D<xref linkend="sect_CID_3488" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_8375e4a1-51e3-4293-85d5-7ad654639c7c">$TargetSite = B<xref linkend="sect_CID_3486" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_496bcc9d-4655-4678-95d3-83fff6f844f2">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f81df570-740a-4d9a-9096-3f11b4f5dace"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1315ec4-e9b0-4c1b-b57a-b83478ca5904"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d2d3675-f83c-46b3-92c4-3d5e9f2e8c21">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f326a462-0a53-4166-b444-2606217820ab">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_55b45431-f112-43b9-bc7d-bcaccd775afc">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3989c7c0-ed50-43cd-b4a4-37c70819339d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_34a2a6c8-40b1-4180-9e6c-3b5d89123ee0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3ba53d8-d190-4d17-9067-bbba8ffb34df">$Measurement = D<xref linkend="sect_CID_3483" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_c88645e1-2051-406f-8903-50e028c5d724">$Units = EV (mm, UCUM, "mm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3dc8adf-752f-4e26-a6fa-35613a1bfe1f">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7649fe4f-7111-4e51-a6b4-82eadf348722"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f48b4909-56c4-4de0-82f5-fc3b309633e7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81b6afde-b54d-4b6a-8e3e-d4f0922cf563">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb7b7c68-c733-4594-b7bf-a5e93d91b006">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_940a530d-a94c-4f33-bb27-89a17af7f630">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f3cb6d46-718f-4df0-9507-abfcc751917c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e963613f-8034-43df-a159-498a38973280"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4efd9238-98a6-445d-b334-12f325904bda">$Measurement = EV <link linkend="DCM_122355" xrefstyle="select: nopage">(122355, DCM, "Arc of Calcium")</link>
                                </para>
                                <para xml:id="para_361b3b20-25ef-4653-a131-6e578ff5c22f">$Units = EV (deg, UCUM, "degrees")</para>
                                <para xml:id="para_2913f715-96bf-46c6-b7a7-87fbac2ca7ec">$TargetSite = B<xref linkend="sect_CID_3486" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0751a425-e9e4-4645-be76-4ebb2f9d7755">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10551f45-a9ee-4960-8841-4478683147ab"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8cadc629-6624-429b-a517-aafea047c326"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6023b46-ec3c-42f7-995f-185c15654b58">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a3d6b80-5336-40bc-9298-05d52b33ff7d">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_750ba03b-7a6b-479d-8136-e5169f0e90aa">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_48420d3b-9c91-41dd-b429-70340c77474c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bdeae7bd-fd65-4eb3-810f-a690cdfe55b8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97dd1afe-9edb-46fc-9601-59af76dfeb45">$Measurement = EV <link xl:href="http://snomed.info/id/408714007" xl:show="new">(408714007, SCT, "Lumen Area Stenosis")</link>
                                </para>
                                <para xml:id="para_09094819-a482-4ab0-adfb-4aa238190b82">$Units = EV (%, UCUM, "%")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80af3501-d391-494e-8a6f-6329bcf9b5d5">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6913881e-ce2e-467c-941c-723f53eafb0a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c9d9b907-d86c-40f3-a076-e90951edaf65"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a4f3fde-34a0-4057-ac7f-61ea89cf3de2">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_89609f29-15bb-4934-ba37-961e7d0a3598">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0404ce6c-c6d0-4890-bbc5-1b4972d55437">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1d394f16-e844-4cc4-8610-e752a5f1dfd2">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d7a72206-7faa-4d16-a3ce-17581d342bb5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_41f2144f-55de-41d6-b384-d08f63dd8112">$Measurement = EV <link linkend="DCM_122354" xrefstyle="select: nopage">(122354, DCM, "Plaque Burden")</link>
                                </para>
                                <para xml:id="para_3c25e3be-3ed8-401c-87ad-2518d1aa8250">$Units = EV (%, UCUM, "%")</para>
                                <para xml:id="para_1feb572b-5cdd-4a89-a869-3aff89ddcd1f">$TargetSite = B<xref linkend="sect_CID_3486" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f61cbe8-0724-4ba6-a433-dcc2b99e354a">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_260fb7c3-9c84-4368-aa69-ac1b4fd5cc26"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e01bbeb-d304-4990-9ecb-281bf43fb242"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26a675d1-77ff-4e86-9a77-fa22b7d57a12">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11e37d78-e440-463b-9e94-880809a90bd1">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7501c16a-19dd-4cf8-a30c-414ba973007a">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5e5f1595-3a7d-4b37-8680-b7dd4b968678">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e61b77ff-215e-4a09-b743-bf3eed060453"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c0f5759-e55b-4d83-ac79-d50b0404f67b">$Measurement = D<xref linkend="sect_CID_3484" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_cc65e149-1a9e-4e05-9768-33211c968ef6">$Units = EV ({ratio}, UCUM, "ratio")</para>
                                <para xml:id="para_815f3fe8-7516-4554-b6c2-216153958f88">$TargetSite = B<xref linkend="sect_CID_3486" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0610d79f-8af0-466c-9933-df8e40080321">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_edf30ed0-2649-4b98-9aa3-dceccbff7787"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c064037-93a3-45fd-9466-84f878438856"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ea7e6db-1374-43c5-94d5-3aa20a6bdf94">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ddf57d21-1635-4d82-9daf-ab429a3988c8">D<xref linkend="sect_TID_3255" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_68b72ee6-a9b1-4321-ba00-848f20d0af8f">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_108ad773-cee7-426d-af2c-a5c342e40d64">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c05137c6-b5b7-4aa9-9fd0-bbd291310238"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb003b9e-17c6-429e-9d76-66db2d93bc6f"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d2a5f37c-bc1e-451c-9755-3ae7a4270211">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b459b66-da2f-4947-ba42-a7ca62e6030f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c28eccb6-080b-47a1-bf3c-2cbae0d8bfdb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9226472-2a64-4dc3-818c-5355e50029af">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_621edf38-123e-4da2-8d24-1291b60ffe5c">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e4e5f03e-5ef6-45da-baf1-eb860adb959d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a4a7b09f-ab08-40a1-a5d0-fddfb52d6424">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_abdbd5a0-57d5-476f-91be-daebcdfb693f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_021de55d-a4e5-4e2c-97e1-6a6c47f13dce">$Measurement = EV <link linkend="DCM_122339" xrefstyle="select: nopage">(122339, DCM, "Stent Volume Obstruction")</link>
                                </para>
                                <para xml:id="para_4bbd4f90-8695-4b09-bb80-f478bec3f3a7">$Units = EV (%, UCUM, "%")</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3254" status="3" xml:id="sect_TID_3254">
                <title>IVUS Qualitative Assessments</title>
                <para xml:id="para_afd15855-75ab-4afb-bc7d-dec0d0dfbeb0">The IVUS Qualitative Assessments Template groups together the qualitative properties of a lesion that are observed during an IVUS procedure. Refer to the "ACC Clinical Expert Consensus Document on Standards for Acquisition, measurement and Reporting of Intravascular Ultrasound Studies (IVUS) " for more information.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_3ed0d7b0-cee3-459b-9230-df6ab5faafe9">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_20537dd6-577d-4ffa-bcb3-54c55b9e5779">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_a65968e8-77f5-491e-b497-c3a8cc7f346a">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3254" rules="all" xml:id="table_TID_3254">
                    <caption>IVUS Qualitative Assessments</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f6472368-ced4-4404-878c-f1d594a9e071"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d909d369-c95a-4c66-b55a-005721e8aec6">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cc13da7a-f839-4939-816c-90b9e8c2ffba">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_59d0a5dd-4807-4e74-be07-fcda256d1ec5">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_99051864-4e2d-4655-a390-cf3c6b03c525">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_906f6e5a-2c1f-44b3-8be0-74ea3865a9c0">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_62264de1-86b8-4987-bff8-ff1c50705225">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9cdf7c06-3c54-4dfb-a9f0-9e95811504a5">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e3413400-a33e-4c3b-9a9f-9084d7f90f7b">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_496c36b7-20f6-4a37-b66c-1e18e043734d">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae84385d-4b5d-4721-a11a-ec23c4cc149a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_013138b7-7234-4400-9d63-2f9aa0b1b779"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0f36593-fbf1-4b15-bf48-ecc11401a255">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8388f9b1-ea6a-47a2-902f-57d78d2ac8bd">EV <link linkend="DCM_122133" xrefstyle="select: nopage">(122133, DCM, "Lesion Morphology")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_68d2416d-e2f4-457e-acf4-bff230991a12">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_83adfb52-7495-4595-881a-5adf521b7e8f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3d59941-f283-48d5-9ee8-711bced56007"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65dc9c70-debe-44b6-8882-c92d43e011b1">D<xref linkend="sect_CID_3491" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_576972be-322f-4379-8244-0306b1ed6d91">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65af5c10-bcaf-444e-b8a7-b96015493f6d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11109ae7-cde5-4a8e-9e26-cf3020eb2e52"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3305d20-ee72-4d58-a7e2-e93606955d29">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d8b1f38-56aa-41b8-b9f8-7c47246a4a32">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5db024ad-6fd6-431d-b49b-84c6f622e657">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7b0865f7-6a42-42d8-aa75-0616882669b8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5388bfed-e000-4568-8b5c-7936945da307"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_509ddbd9-4766-4cc2-ae46-455e70eb2a37">D<xref linkend="sect_CID_3494" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c176e4b-ff72-4395-8b1c-6d5a1f133133">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6431084e-b2ca-4341-8989-ea437d3ecaa3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4cb0dfd8-f02b-47ef-835e-ce024b8bdbe0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa20cec2-3471-4abd-978f-edd9c5262434">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_244e25a8-80a1-4059-afc3-0700395c7d92">D<xref linkend="sect_TID_1350" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d4f5ad27-6e67-4696-ba58-bcef92ee7098">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b0929c82-9b11-44cc-99f7-b13730727ac2">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef46f89f-6124-4d2a-ae73-90f97d68c6a7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a23dbe3-f796-4b7e-b5a3-1033c519a4d9"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ec38588-7e50-44ed-a17b-64f8c391291a">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1da6f49-16f4-4e0b-bb1c-9aa08a603e64"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ba0bda1-b916-4fdf-94b8-09618255d902"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e161fde8-4f22-4dea-a0a0-33f3b61cdc6f">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d11c3a75-5540-4ba1-8359-7f2fbc345cd5">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e163c473-1cc5-4164-8dea-0aa2b6c0294d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3bacacea-e40d-45c9-a967-040bb8c052aa">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e16212f-ed97-4631-aedd-9377c698bcf7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3231bc18-2eb3-42cb-b29a-e51718c511aa">EV <link xl:href="http://snomed.info/id/710864009" xl:show="new">(710864009, SCT, "Arterial Dissection")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51bf7e96-7f2c-4e90-a91d-b50cd97aae40">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b82ca0e-19a5-4458-849e-636522297246">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad32e464-8bb4-4a4f-97d6-0937dcf8b6cc">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d61a6cf-614a-494e-8e46-3574b68c5d3c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c16de2c-ba77-4c5a-9809-108e3afefcd2">EV <link linkend="DCM_122387" xrefstyle="select: nopage">(122387, DCM, "Dissection Classification")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5bd0a447-4342-46b9-a3a8-4c9dd78f06c7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9476785a-862f-4e81-8aa0-d5a80e4f8994">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97a6ffab-f596-4797-9153-926c0be203b3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ed37f0c-5557-46d8-a499-a274bae48a42">D<xref linkend="sect_CID_3492" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4514866d-a017-4987-b64b-dd10320da816">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42ca6671-2208-4e11-892b-c980d243ac08">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84a69694-fa59-4c5e-9deb-0e6228739998"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_080a3362-e65d-43b7-bced-ddd6b40c27b6">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e6d4920-1ed2-4adc-b7dc-396ca7be9ad2">D<xref linkend="sect_TID_1350" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a3780265-bc44-486f-b2d4-4971b5d75729">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4cb7bbeb-097a-4c98-91fa-03740fe0789d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_15cb6817-3716-42bf-a712-2b9271720947"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a82c2d2-c60c-4882-bda2-6094835ebb6b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1df203b7-8f06-4c02-acd9-71bc7894b503">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_40704424-ce92-4a51-86c5-8ec9a6f58e5f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17d146b3-3baa-425d-9e27-62a65c5af02a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5dbd12b5-a8b5-493f-b380-e415ee93b8b9">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_07984273-96c3-424f-b33b-af6667e23213">EV <link linkend="DCM_122391" xrefstyle="select: nopage">(122391, DCM, "Relative Stenosis Severity")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_41583077-1086-4808-85d3-2c5c5ddacba7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_200018af-1c71-40f6-991d-e18b98fe31a8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab7f9f78-7ec9-46fc-816e-6c340b3c187a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81e592ab-7a3b-45ec-aa3d-a83fc3e97726">D<xref linkend="sect_CID_3493" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f48a418-54d1-48da-9d1e-3dedc5d67375">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0afa0a62-d62e-4bd4-a0df-f11942069fdf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_efbd97b0-9ff8-410b-87e4-ad582bcd891e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63e841a4-a0c3-4c8c-8251-48f7aa736cd7">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba65ba98-dba2-4955-b1a6-f68538245d9d">EV (108, NCDR [2.0b], "Previously Dilated Lesion")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_91dd97df-68cc-422a-87a0-84419f16e341">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2ec5756a-6bf9-463f-8df3-fb45d7d891dc">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_045eb957-cc8d-479a-9baf-b054bc4dbb44"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_398f354c-ad28-4552-b5ac-5fdc10b5f3e3">D<xref linkend="sect_CID_3750" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f05f1ad9-fb40-467f-8506-c7642f1441a6">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_123605e5-93e5-404a-a298-5841eb3d5b6f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a2762cf-17fe-48e4-bd46-bc4eb02b6e56"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef66108f-556c-40b3-8633-e2434194a661">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4778eaee-ea13-4ed7-ad3d-97344e04d2f1">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dee9efa4-5863-4290-8bdd-28fae6ceb2b9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e62c6bff-4d21-4f37-ad7f-36abe5077c45">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_344d67b6-50a5-42e5-a486-be535c82b8e1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb8607af-984f-4228-8c8e-8f200758a32f">EV <link linkend="DCM_122393" xrefstyle="select: nopage">(122393, DCM, "Restenotic Lesion")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7a9763f-61f8-4588-9565-5411fb52406c">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f455adb3-2cab-4bc9-a58b-abbdfbe22560">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_154d0a18-f9dc-48f5-b4b4-d55d867fc33c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96404677-91d4-4729-b439-7269c13014ad">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b4ff83a-f34c-4b7f-8319-ce94b1572e66">D<xref linkend="sect_TID_1350" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dc5159dc-f2b3-4799-a177-b4fa4602efbc">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5082fc8b-57e4-40cb-b46e-b67b92fe594e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9890c419-e159-4227-af0b-9eeb95bdc54f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fce295a0-1b2a-40f4-9f12-dcd63324048e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62b2ed7e-d106-4efc-94f2-6c6cb9c970fe">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2675fbb9-ebd9-4dd4-bf2d-3b6da573a518"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91025fed-f2d1-4333-a65a-d61584dd3c46"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88efe6e9-50fc-478c-b995-61a13b9a429c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee081b5b-1672-46df-a9c4-57058528821e">EV <link linkend="DCM_111009" xrefstyle="select: nopage">(111009, DCM, "Calcification Type")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf16ea26-8ed2-4f24-b256-b5ee719cf589">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e9aff1c3-47d3-44ad-8f2e-55dbd964d40a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54666df0-5bc6-42a3-8207-2b847a92e73b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9d70d79-c3d4-4010-aa8f-32136b76608b">D<xref linkend="sect_CID_3489" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3255" status="3" xml:id="sect_TID_3255">
                <title>IVUS Volume Measurement</title>
                <para xml:id="para_c044b51f-84a2-4ad0-83c4-6a0a3bd1706b">The IVUS Volume Measurement Template contains information describing an IVUS Volumetric measurement</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_9b32fb0e-70a8-459c-ad4f-bb204d88172b">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_2d8a76bc-16c1-4aaf-ba0a-8cbe774125a8">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_d9136929-8a19-4621-8c2e-dc581769f1da">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3255" rules="all" xml:id="table_TID_3255">
                    <caption>IVUS Volume Measurement</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8a6c107a-9c86-4ec0-97f9-072395e8c513"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_00eeefd9-73ca-4521-9a16-c7ca6f0b2bad">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_72c543b7-c479-4f37-b3e0-e71b6fd54618">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c6f721d1-9c71-400d-ae42-e15718dfd076">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5098ecd7-b5ed-4dca-a211-a232f2857ca3">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_12431338-1584-4c1c-b6c3-17b72e68d47b">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5f3904b2-4dbc-477d-9af1-8e96823df449">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a0c1b34f-c636-44a0-a502-58e37b470692">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e72c2630-9dbf-47bf-b969-fb67ffb089fe">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af7f4907-46d7-41ea-a2b6-a252d7d9848d">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_daac7012-c8cf-4b5c-a6d6-c9ee708b74b4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e822a77-a576-4968-bb88-36b4d4a2a836"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b933e340-8053-43a6-a340-d7a562c5369f">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3f30079-bdad-4b72-9e15-667985063597">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4775eca0-c4eb-474a-860e-cdf492758ef9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2149d090-42f9-4b0e-9fe0-917884e935aa">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6870fea0-4770-411b-b08e-638a40076a5b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4ce01c0-4397-447a-98f6-adc9abe1c675">$Measurement = D<xref linkend="sect_CID_3485" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_8652d01a-6d5c-42e0-bdf7-66eab280e605">$Units = EV (mm3, UCUM, "mm3")</para>
                                <para xml:id="para_9eefcfe8-2b19-41ae-87b0-05b5db1b36ed">$TargetSite = B<xref linkend="sect_CID_3487" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e8e28c6-e1e0-4d37-919c-b05864711893">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5adbe54a-9cb4-40b0-bb4a-93a6b860c1f5">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc481353-1e4c-47e3-a256-ebd33f0aa6bc">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8abe294c-ec95-4e97-bf65-b9a1539191cd">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51881aea-5bff-4a49-98eb-6f3ecb80e699">EV <link linkend="DCM_122336" xrefstyle="select: nopage">(122336, DCM, "Vascular Volume measurement length")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2877c925-6e3d-485e-830a-c1541ddcef07">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_802d7407-089d-4e99-84ce-3009e2dc74d4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4362a83d-1f33-4279-8cc3-73cbdf77029c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_64b11f35-2569-4de0-b86b-3ad347232119">UNITS = DT (mm, UCUM, "mm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b9c1157e-c5ff-4711-8d36-79d8d2a8320e">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4327e792-29c0-4b00-aa3f-928163f5fe44">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df40600f-5ee4-40ef-83cc-4ae68a74e37a">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f863e525-50e5-4e60-bafb-4274a6ef6a7a">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d71cabb-1ee3-4b0b-be9b-dbb526974175">EV <link linkend="DCM_122337" xrefstyle="select: nopage">(122337, DCM, "Relative position")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_18ddf617-aa13-4b7b-af11-5225ce2396f4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2a0080ca-ed7a-41d6-b367-3e0a0bb130ff">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb4b4489-9ade-48a5-8be1-a0e2d053a7c0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f23580a-0231-4f89-88e6-3bae1cba0e62">UNITS = DT (mm, UCUM, "mm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26601a8a-c861-4819-96e4-38f008d6cf89">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e1a72a51-f20a-47b8-9545-128e3131260c">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed8949ea-109d-4a65-afa8-ee42ddb1fbf0">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb5e4a5e-e0d9-43ab-8d02-f98f604e6b18">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2a7f894-cf55-4e4e-a04e-2df958601349">EV <link linkend="DCM_122340" xrefstyle="select: nopage">(122340, DCM, "Fiducial feature")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ae55eaf0-657d-4b8d-b6c0-81c7f5c77006">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_95ed62a3-9d56-48ee-8e3e-69be798ac9ad">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8605858f-ffac-4a46-89c1-85f988969b25"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c2a939e8-645c-49f7-a8bf-8abb993afbe5">D<xref linkend="sect_CID_3496" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
        </section>
        <section label="Stress Testing Report Templates" status="2" xml:id="sect_StressTestingReportTemplates">
            <title/>
            <section label="TID 3300" status="3" xml:id="sect_TID_3300">
                <title>Stress Testing Report</title>
                <para xml:id="para_a8ea59d5-655a-4fb1-99bc-2e1270fc9cb7">The Stress Testing Report Template is the root structure for the representation of measurements and findings of a stress testing procedure.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_745028ab-8420-4399-8f70-0f51bb9ce170">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ced851de-52c4-4f9d-aa0b-ab165a1e7041">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_db62c919-6516-4c72-95e7-5edccbd6489e">
                                <emphasis role="bold">Yes</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3300" rules="all" xml:id="table_TID_3300">
                    <caption>Stress Testing Report</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8cf4a0c2-711f-44be-8364-7c2554361e8d"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7c7a042a-9c06-4623-82a9-9dbff7ddb87b">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_251841c8-4dad-4fca-92d1-4e853e32913f">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_39d0de70-4942-41a4-9f6c-c2477422ab02">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b8ddbc7c-ff88-40c7-9bbc-394218570dec">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1aff7201-3ee5-40e3-8be6-cbf226c8989d">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_caf2d83b-2a51-4e4a-b537-4bc7d95dc690">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_98148d9c-4982-4109-9e66-b5e04938f017">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a73647aa-d6ba-48f2-989c-2ecc412246d3">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ccb73039-6471-4bb0-87fd-9c641c225393">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2523e4fe-066a-464b-b1b4-85675c092932"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c2f91c3-a509-4d79-9e93-e68cfe897986"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7e197ff-d79e-4cd3-9abd-3b869c21ce0a">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_285c6463-3e19-4e27-8fff-a51224433710">DT <link xl:href="http://loinc.org/18752-6/" xl:show="new">(18752-6, LN, "Stress Testing Report")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2debc632-c03e-4f68-8ea8-7bafbc01cd3b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b52ae835-9b1d-4e95-9a44-675a5a72d74f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b469b834-e10b-4d07-a7b5-3701af741db5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_466aa11f-b7d3-4f4f-a9e7-4dddde537a75"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38ab9785-3bd8-48c6-8a06-ea2b0f0da8c8">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1f861185-850a-47ba-be8b-e1658ecd488f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2958f0e1-2b8b-4037-b433-04ccaee5e82d">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc738251-9069-4bab-ae99-470b27b566c7">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe66eb12-9822-4946-85a2-bcecdc9efa39">EV <link linkend="DCM_121058" xrefstyle="select: nopage">(121058, DCM, "Procedure reported")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_508e1f09-291e-496b-9386-9dd3eb2a97f1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73843f25-0e94-420c-8f7d-6bb9169189c1">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29f89892-6207-4078-982c-d09e3c8f9f4c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8e74c05-19ee-4072-8443-d68eee19c11e">B<xref linkend="sect_CID_3200" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c246d22-dc1e-454f-a3d6-9adeafb296a2">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c48d4e6e-80ea-47d8-8740-8c407358b689">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e61b05ae-7caf-4881-9a55-e5d7916115f0">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2bba419e-7673-474f-bc52-8fa3c4c5c3df">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cfbbbeb0-b00e-4a52-a8d2-6c2577192438">D<xref linkend="sect_TID_1204" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c6d34838-037d-4001-a7b2-e382ba6da392">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bd87ea56-0acc-4ec6-ba3c-23e75026a2e7">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_decd158d-ca52-498f-a2fd-c51ec87f0e63"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6dc3e291-65e7-4089-926d-29b1e30804bd"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd2b25e3-40b3-41f6-a833-2306c1dc9aa2">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3630d7b6-c39f-4868-8fe1-e39367fc45c1">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86088b55-1e08-4b86-8d26-af841a148cb3">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70874c46-3856-4803-95ac-f11b6e6fd468">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af3a1686-8a11-4108-a29d-9640154235f2">D<xref linkend="sect_TID_1002" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a8ddeada-5da9-4724-b328-3c3a7a05c1db">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_961f8945-f948-4e45-bcea-96531b04865e">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17c3594f-6f56-41bd-986f-6093263aa2d8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69487cb6-5446-4cd0-880e-cf6788eaadd7"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b2ce48b-bcde-401e-8f5b-46955d6cfc08">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be18dce9-a53d-48d1-8057-40031372f43a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_19ba3906-4c0b-47d1-a17a-d2aa32811f15">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_409dd59b-4f5c-4331-88bc-dd4564ba8463">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ac40f88-bf3b-45b9-9115-e0a4d328083c">D<xref linkend="sect_TID_1025" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_027b7598-9dac-40c0-aa64-18c3c259d1b4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_609df0fc-6ef8-4ed5-a373-0ad7da76c6ea">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b9897c2-e67d-4185-8691-79756699a5aa"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7161452b-845a-4a83-b051-36aff034d045">$Findings = D<xref linkend="sect_CID_3201" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a3a3e82-8168-4cc6-bbd4-db740a638036">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2c819c9-6f08-4a99-89e5-98b1671275fc">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_833c44de-2ad0-4656-87ec-a7b7ef71a36e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_45f7d6df-8452-4ac7-9c05-c1ba5f741bd4">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c6f36d83-8b86-4611-b0b7-da7ea897a6d0">D<xref linkend="sect_TID_3602" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb44b81d-9179-4643-ab95-266e3a417649">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_afc5d978-20dd-4dd8-a19e-5c28c72c417c">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e0bfab0e-c218-4f5a-bfc0-7fdd8d89b012"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df6ab8e0-ef78-43da-a850-f8f7f4897420"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39ec7c91-c0be-4b31-8c42-e2290fa5884a">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5192563-c5db-491d-94c5-066cb9b7e127">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e15d9c0f-2963-454a-bb41-2f51e4406533">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46ecebb7-58ad-4bc0-9c76-d9776372259e">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b1581d0-a355-43a8-897b-164b690307ba">D<xref linkend="sect_TID_3802" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_35fce214-3107-43f1-bd90-4978f4d5a0cb">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c8564a36-a9ba-400f-9f73-dc146d9f4730">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6d648bd-f770-41f7-bd92-3ca6602b7f9e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38295955-5df3-49d9-ae99-a3e2dc74ad7e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ea2fa2c-1b48-4932-98df-05eb3f13e242">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_53deda5a-f871-4041-8218-63c599599f8c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_100d2834-92ac-49f4-a6b6-dae6bf9c6f9e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6b56c80-c7d4-4fa5-be93-ce47d4d0b277">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b89d7f69-20d3-4b75-af66-e0edf7da0582">D<xref linkend="sect_TID_3301" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_abbe0774-0a46-4f9f-a8f1-17c0793355ec">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6d099429-e861-46c8-af84-b64f6823cb06">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2319d289-3be6-438a-83d1-bb89ad7bc006"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06751f57-fae6-4f11-a682-a6a18c2355c6"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e61af92-9b1a-4656-acb0-dbbf1a2ac536">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a79b79f-fa5c-4a94-9a4d-465c7ff8840f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a957f420-b1ff-4da4-84eb-dba922a41a97">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_037184e1-4cb9-4edd-9bb4-a4c1c39973e5">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_149ee4a9-98a6-4d8f-8195-f5688f09b89b">D<xref linkend="sect_TID_3303" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_910c1df0-1089-4f31-95e2-b14ca7bf0dad">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85afaa95-03c2-44b1-ab61-015d3a03136a">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4ee3769-a515-4dd9-8edf-989bd3b28282"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d59f35e-bbd8-403a-b652-e4ee7e3be281"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea36e455-c13c-43d4-9c2e-0a1365c2fb99">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65aace42-beba-42d8-b8c9-25c703be55ed">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_18815992-a27e-4e33-9836-c0bf3a64f322">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8495fdb-f8dc-403a-85a1-2bef1f5a2970">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2a56221-56ed-40a7-882b-ee5d1662c553">D<xref linkend="sect_TID_3311" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_746da956-432d-4df9-9492-dac9c97511cd">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_562856c1-a7cf-462a-9fbc-0340623e5427">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_178a0241-ba3d-4854-b89a-2f0137b7ae32"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02be1f4d-c0b7-4d62-a04b-be115aabf6e1"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2a2ddca-2621-470b-b5cc-b6adbe84fceb">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce8b2ce3-a488-4f16-bd1b-bdc4312bd65c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aea3fd73-0482-4d92-9cdf-7dc39b004ee5">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f7e7d85-42dc-42a0-8bd9-7eb003e7046e">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_117bdaad-68e0-402d-a325-bb8a86dedd8d">D<xref linkend="sect_TID_3318" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_420ecef4-6618-4221-a34b-b1866d5c0cef">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0cfb29b8-b580-43c3-902f-42f9b66a8d37">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a975f80-ee08-4b51-bb38-e9018b002b71"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2aab4f8-06fe-4c2c-a0dc-ebd9078d3e83"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03846111-9927-4869-ad66-1814250d1c3e">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc1b621a-0d1c-44b7-8014-8daaaeba9b47">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0ce762e-a7e7-4d0b-b285-6e204c7d64af">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f431b7de-8ee2-4da5-a985-5fbaa2315c93">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f34956f7-c28c-4eac-8a9f-0b4a216dd34c">D<xref linkend="sect_TID_3320" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_88ab614c-c437-4d69-8098-376dce3961bb">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a488f60d-ca4a-4639-a4aa-85194011ebf7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22c67ed1-07c4-45ef-b170-dad1eb62b6ef"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc0acaf9-415d-413f-867d-976ea8f03872"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3301" status="3" xml:id="sect_TID_3301">
                <title>Stress Test Procedure Description</title>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_9f37555b-08b6-4d9c-9ea9-6060e1be2fd4">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_10a875b3-76d5-4624-a123-a82a4f64cccb">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_7615785c-c2db-4d28-a3a9-4415cad63a60">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3301" rules="all" xml:id="table_TID_3301">
                    <caption>Stress Test Procedure Description</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6be1f779-ec8f-4fe7-83a0-309a2d2e5654"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_99d4006b-22b3-432b-b444-7a0602c70de5">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ecd92710-3c6b-4f42-916e-7e3eb4ade6a8">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5551f23d-25b5-4000-b9b2-3ec0e76e79ae">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f2b12d04-6ce6-42c6-8a20-2894223ef2c4">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_55246bbf-7f38-42cb-8af8-c86fa6a76e7c">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_48ae1463-a803-46de-a11c-6eef65e96373">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d46d96a1-a0d1-4f86-8c93-fdb86b234d7c">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8cc40557-6c47-4476-bdbb-c104557bbc55">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8df117b8-0f7f-4f7a-868c-c6fe82b0f54d">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee1cb18a-2c6f-47c7-89ee-bab1c55539af"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f28af308-f16b-4c06-aee1-383a5d10c4a2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_549533e6-12ec-405d-82ff-12843afad606">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f6e669b-4ef1-4b13-8360-f8680321df05">DT <link xl:href="http://loinc.org/55111-9/" xl:show="new">(55111-9, LN, "Current Procedure Descriptions")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_185566e3-36f4-4952-aefa-584f21a46a87">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_43232826-316c-49db-8dc2-9972a294af10">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_209c0ab9-2feb-466e-9531-a2305d5b97ca"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73ff875f-ad78-49aa-9e50-17703719f47c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c49a931f-96c8-4675-a824-f029ae038205">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8702d92c-9333-4126-ae86-1229938109c7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65712db9-a354-451c-928a-5d4438f5cd94">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_629cc5a5-e086-4145-b21d-7d168ab43e39">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a09c9497-c986-4c43-85d6-d273644898c1">DT <link linkend="DCM_109056" xrefstyle="select: nopage">(109056, DCM, "Stress Protocol")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_074537c6-15df-4e65-b824-ecc2e41c55ac">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f865560-fc52-4f7b-8fe5-b341b4399d7c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c2fff00f-0393-4855-9a20-dfa40c4aee19"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2249bb1-cf67-47a3-8b1b-62b47b247682">B<xref linkend="sect_CID_3261" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab1feb8b-a418-4fe4-bf32-cc228140e2ee">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb7cbfae-5ad6-4eb3-a9f8-cc7066762a08">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea4e5382-e3f3-49ef-9dad-e1f99581d4bd">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b8f79daa-873a-4ffd-ad2b-ff113e884434">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2d8f4c06-5124-4bf1-b5c2-be75fcf4d916">DT <link linkend="DCM_109056" xrefstyle="select: nopage">(109056, DCM, "Stress Protocol")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_317dd131-32da-4214-a0df-bf2839640e19">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_59f0d2ea-de6b-44a6-9571-7a7f3795710a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d467402d-a77b-4ced-85e4-2f6415875475"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_204b0c80-a171-4885-ad58-15aaef023b0a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c6c3101-e321-4b8f-94f5-e9006e1c4f49">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4b89e5f-96bd-46e9-be15-684710afc37e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_712f92ad-587a-430d-831c-8b7ce99f24c7">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e15ea23e-184f-4da6-ab0d-1651ed35de51">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dbb3c884-10da-4dfa-aa4d-97769929873e">DT (10:11345, MDC, "Lead System")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5984f25e-db61-4d08-b1be-c206577d4b0a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c1a78d9d-7cf8-4165-b80e-5c260e43021c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74bb2aaf-7c22-4239-8025-35fcf66debe6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f67531f8-278a-4a6c-9054-343268002402">B<xref linkend="sect_CID_3263" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ceefb39-14c1-42de-9af3-7070589a3c9b">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88232d10-b3f4-4317-9237-08380cdd7f4a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_efe5ac84-ffb9-429a-8aa0-b6b23644e060">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d7a47859-14f0-41c6-859b-99d6f074e821">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_66b55921-e606-42c6-bed8-51d3e9224e60">DT <link xl:href="http://snomed.info/id/111045004" xl:show="new">(111045004, SCT, "Exerciser Device")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_62970beb-3f75-443a-9f1a-d4d1443a69bc">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_50a6e7ae-73cc-43d7-b282-1d817c64ad1d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_386c8c14-d020-42ba-9e3e-772c7476d73f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_64e0d0bc-642c-47d3-b34c-8b166d8b6ff2">B<xref linkend="sect_CID_3203" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1df155f3-1c76-4212-b45f-80856667806c">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6fea48f4-b607-4ef9-80a0-9f9e358d4e18">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f93a817d-772a-4552-9e93-f1be5d703877">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e245b4ac-f772-47f4-a4ec-d066681f8f5a">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55630fde-4219-478f-b777-7359d6334c87">DT <link xl:href="http://snomed.info/id/246489000" xl:show="new">(246489000, SCT, "Pharmacological Stress Agent")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_75d8ca21-ae0f-416e-87df-764e8389f154">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b21d53c5-8bf7-4f06-ac63-5c4938feb918">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3840ea39-9e64-4caf-8bf2-1c814b6c7dd5">IFF Pharmacological Stress used</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb3e65d5-1e74-4435-a8b8-f3c69d5a2476">B<xref linkend="sect_CID_3204" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ccb1f4f7-7924-4d54-b13e-574e8d38d116">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee1e4a8c-1652-4944-9d26-9bc06e277c70">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec5b595b-d4fe-4524-9815-df038bef040f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97281643-1ad5-452a-9b5c-8e3d29510149">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10a9eafa-aa51-4efe-8995-5cbb86b7d589">EV <link linkend="DCM_122700" xrefstyle="select: nopage">(122700, DCM, "Indications for Pharmacological Stress")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1e1b3970-518c-4bcf-8f28-48d6bdae8554">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_96b54e9b-fa8b-4f59-8329-0f5164904c5a">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a69e9e1c-b8f7-486d-9165-a0ca285613e3">IFF Pharmacological Stress used</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ed601c0-08e8-4616-b0e9-392370574cd0"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c745b371-d1c9-4276-abaf-2c0c5822b760">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04a4bcfc-4791-4050-b6ec-8ee209e123b3">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c6cf0060-ece6-4222-9dd6-1bfcab128ccd">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_18f374e5-1bbd-420c-ac60-5d42d787acc3">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_485c43bb-0a67-4712-afe8-a17a937f8062">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d4e9e21f-ad58-4da1-af96-3f201778c1ce">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_34eea861-a98b-4ccc-9dd7-9037b0f718ec">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69d149f8-2994-4cbb-ba38-6047b4794bad"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51f2f717-d5a5-4f30-983d-24d32d1af8ee">D<xref linkend="sect_CID_3205" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38f647d8-ed68-4fa8-89a3-7e8260a87af6">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_365e26c5-f65d-45fc-8868-98a80831a1e2">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eefc5980-f2cd-4ea6-95b3-d89e42e40fd2">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5bf0c531-3b29-4d3f-812c-62c61167f750">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22885013-e52f-47c8-98fd-2df7afee2586">DT <link xl:href="http://snomed.info/id/363679005" xl:show="new">(363679005, SCT, "Imaging procedure")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6a546990-c197-4960-a219-aba8d25d6ed0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1a161601-ce32-4ca2-bf16-36aa761efcbb">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_447e12be-68a9-4ed7-a8df-9ec4441ff60c">IFF imaging used in procedure</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e07fae3-a9e8-4d11-9c0b-a9c4fffa8457">D<xref linkend="sect_CID_3206" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fca8532c-f2ff-4dfb-8320-0712b9f6b126">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7ce934f-2fc3-4d11-96ed-7269bc47a66f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e631cb06-cd48-439e-8316-bc97af8138a5">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e427ad78-e834-47f4-a0b3-486bb34d8372">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6606275c-ce49-4467-b2ce-f993016d33be">DT <link linkend="DCM_125203" xrefstyle="select: nopage">(125203, DCM, "Acquisition Protocol")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7d8ea7d9-f380-4232-8e60-00d912e2e1dc">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4401f6d4-0259-4bec-b138-11d8ceb04e1a">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6601819a-f9f1-474f-9afb-0c74be0321b3">IFF Nuclear imaging</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be459edb-6082-4758-a6ff-bb400f419852">D<xref linkend="sect_CID_3110" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0260cd7b-9775-4a66-a2be-db0976005743">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4999a359-eb5f-4352-ae3f-066160bb83d6">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73efa3f8-10f5-4568-b089-1575a0515387">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5dac3f7c-bd7f-44a2-b66d-aedee0b81c66">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_01c0ebd8-a3cf-4d70-bdc4-a61f6abdd130">DT <link linkend="DCM_125203" xrefstyle="select: nopage">(125203, DCM, "Acquisition Protocol")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_987107f7-b168-489b-ad10-5b99c4c59d86">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_532b1f06-b8d5-4227-a1c9-3737681f7e44">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c05bb4d5-189a-44cc-b39b-2ecb3acca1be">IFF PET imaging</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf5617ab-17d0-487a-a57b-2d4cc2463a8a">D<xref linkend="sect_CID_3106" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99690b0c-936d-481e-9cb1-47d82400a393">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3aa38c96-0c92-46a6-a8c9-d89e537d088b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a6b6107-dbb3-4fb6-947b-158a036aae64">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0cebaba-22d4-49c2-85e4-c3a773eeb239">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de3abace-dad6-4eae-a212-78bd5276e669">DT <link linkend="DCM_121141" xrefstyle="select: nopage">(121141, DCM, "Image Type")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_56c037c6-fb00-427b-a925-b139b26ad811">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_31c974b9-f48a-417c-894b-78592c745ae0">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6789e42d-b331-4a66-8e7d-4d24401465b9">IFF Nuclear or PET imaging</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ce0ec02-4697-49d3-8c42-529b051128b7">STATIC, DYNAMIC, or GATED.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98a981c5-1c42-403d-a91b-1e447b95478e">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1f6aa35d-e90b-4248-9a13-81bfaffac7b8">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_970418ff-8e08-4998-99ef-39f95b721a0e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37906507-caca-4325-a317-5c8716ea64ef">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d4dca86-27c9-4693-adcb-5c1f72e8ba92">DT <link xl:href="http://www.radlex.org/RID/RID11248" xl:show="new">(RID11248, RADLEX, "Cardiac Gating")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f9e03781-4300-4960-aeb3-02a50917867c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d1819775-dc45-4ab8-9ca6-e21719d271cb">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_506898f9-1b51-448a-b218-a40df5118608"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a06625d-83d3-4eda-9de3-f2447af55323">D<xref linkend="sect_CID_3104" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1309e803-2a3c-46fd-9212-5018b8cb0966">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7068c718-f347-4cce-a964-4507ff7fd9ad">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c02f632e-0e73-47a8-a82d-8cbca4e40eda">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a1b3888-5197-4e6c-94ec-3028e5b0f1ed">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22164d07-24d7-42cf-8c35-4f45776cdc86">DT <link linkend="DCM_125203" xrefstyle="select: nopage">(125203, DCM, "Acquisition Protocol")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_672a33be-6c89-4ed2-a1d3-c28b8d43e235">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_43b55513-d2e0-4d88-bdfd-90729554a815">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce22792c-6f4b-4bb8-a9fd-89f3f6c01587">IFF Contrast echocardiography</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_18e09842-c49b-43a7-925c-151c5ad87c4b">DT <link xl:href="http://snomed.info/id/433231002" xl:show="new">(433231002, SCT, "Contrast echocardiography")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a6e53f6-4dcd-4ee6-a5f0-2a805534dc33">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d274a80-4f44-4a0c-b6a8-05e930b927bf">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fbec3110-b173-4fff-9081-61e8e6fb8204">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9bed44a-5b55-4225-87b7-0931e8d9d284">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_db86aa45-1f1d-457a-a85f-5249f5ab6969">DT <link linkend="DCM_113743" xrefstyle="select: nopage">(113743, DCM, "Patient Orientation")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d478cfa6-b944-4082-b892-1afce54339b4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5f0e38f8-f0ae-40b8-a4d2-2fb6a7b26d14">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f3999ff-6c21-4fe9-88fa-1468c4d9cef8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d06b6d3-dd80-4bc9-b984-9882739b3011">D<xref linkend="sect_CID_19" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0487b121-b0ad-43f8-bc62-8d5d0347712f">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_846ba7c4-9253-49f7-9a55-6393bb050995">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e676a61-8cd1-4e6b-9694-f0d68d27c4b3">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29872e65-cccb-48b7-902f-399aaa0a4ea0">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed4476c2-057a-47f6-bc5a-89430cab252f">EV <link linkend="DCM_113744" xrefstyle="select: nopage">(113744, DCM, "Patient Orientation Modifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b9f89d22-73d9-4a82-b1ce-6b3dd872a6ee">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7bfadc7e-7c55-453d-b054-78d2d854e679">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bacb228f-2508-4381-81cb-9667b28ee955"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2810e878-03f0-40af-9435-0592af5c99bb">D<xref linkend="sect_CID_20" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97b244f4-989d-4bd6-ab43-70897adff06a">17</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c748178-cf6e-45c3-ad40-5d59339f9573">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05429be6-4bf6-45d2-a419-1bcb47b777a8">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1f1d4ca2-9794-489a-8eed-bff804ce4558">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54378a6e-354e-49bd-998f-60277df4645f">DT <link linkend="DCM_121065" xrefstyle="select: nopage">(121065, DCM, "Procedure Description")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4ace6dac-3d98-4ee8-bdd3-abdbd564b448">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2b3047fc-3f2c-41a8-8f2a-22bb5ad29676">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dee5190d-d7b9-411e-8740-b578cb41ed49"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04cfdf15-c26f-4169-839b-f60eced2d467"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0c09832-6fac-415d-acbf-5f200ccf71ba">18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5677297a-9e7a-4f66-9ce7-eac40a099ccd">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d4b5fdd-282e-411c-821b-3410e99d6a51">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9f5fc81-9985-40ca-b5ac-b829ea34959e">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d962e5b2-681e-4bde-a4b2-ee447bd2376c">DT <link linkend="DCM_122701" xrefstyle="select: nopage">(122701, DCM, "Procedure Time Base")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_269de22f-0130-4d7d-a131-a077695ad27d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6224b358-0d45-42f4-adf3-f4a07eb3785f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0bd55f15-0396-44a2-8bf8-2d85ff5f84a3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8b86f57-7849-4cf4-b9ec-c4147d29e4db"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_bbe74e40-7a6b-4645-9f9a-3fd09df0d26a">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7baa20e1-a6cd-47a4-9504-4849d238efc6">Row 12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_acc0b56d-0688-45ca-a4cd-e5d5f1b8cbc2">Image Type may be copied from the NM Image SOP Instance Attribute Image Type (0008,0008) value 3, or from the PET Image SOP Instance Attribute Series Type (0054,1000).</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43b793f5-e7e8-4578-93eb-5ec2d830b5bf">Row 18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd879376-27e9-4cd4-b832-e2921ccfcbcc">The Procedure Time Base is the time from which elapsed times are measured. The Study Time (0008,0030) may include the patient prep period, while this Procedure Time Base is typically established when baseline data collection begins.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3303" status="3" xml:id="sect_TID_3303">
                <title>Stress Test Phase Data</title>
                <para xml:id="para_89e0b8c7-6e38-4368-8348-9f0147a49e25">The Stress Test Phase Data Template provides a structure for measurements acquired during a single procedure phase.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_c9ba8a1c-96ee-4b58-b6e8-b365b7242fe5">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_b1d3d3d5-a054-413f-a94d-c460742f65ff">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_731b70e8-8967-4a72-a1a8-856da810256e">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3303" rules="all" xml:id="table_TID_3303">
                    <caption>Stress Test Phase Data</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d6b73778-639b-4478-a067-4bc3595ddf2c"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7f625bdf-1399-4c1a-a1f4-b08639ffbebd">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9d2239cf-c6c6-4d8a-b60c-5dbd3508878b">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_04b64436-3daf-4c60-8869-aceb774777c9">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5c575de6-3625-4d61-ab03-5af7fd7c267d">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_37635704-9782-4aa2-85af-4fceca11c1b4">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a8663f40-1cb6-4721-b3d7-9981f8163c40">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_258ec688-c925-46c9-992b-f6a9d0d2fe2c">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8998b4e3-a96a-4776-90bc-fd267b47cd22">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_15bf7b39-f000-4e25-91b5-3010d30b71a9">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97db108c-3d82-46b3-b066-d6f65e361c76"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7adb093b-be6d-496e-b3ac-27bcbb1ad66b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3eca71c-09d2-4d48-959a-24adb0bb5a92">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef0c96c3-ec13-4e31-ad9c-942404eabcd9">DT <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_496435ab-2a84-4eaf-82b5-6a65ffe171cc">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b9610a9d-2984-4da4-8c6e-50ac4d735bd1">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd712087-b005-4c1e-86b9-5b4b86ac7d97"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d34ab1a-8882-4233-96bd-fd592c322ca9"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_927ff261-8087-4e6e-9fde-d2844c2e79f7">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d12fd1d0-f562-481e-b772-5c74ca535706">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25b3e1e3-5412-4edf-81cc-026dfd510854">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8be8b7d5-6918-453b-adfe-0d85778e0853">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65c383ba-ccfe-4f43-bf70-a8d53d6f1183">EV <link xl:href="http://snomed.info/id/128954007" xl:show="new">(128954007, SCT, "Procedure phase")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ef1d8df3-c8bd-4266-adcf-a0e3bb203744">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f132959c-45e0-49b6-970c-4f084fe88b47">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7889bb9a-33ea-48dd-a8c7-f752c5b2925c">XOR Row 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_680a3810-e4e8-44b6-8f46-8d0fb592bf08">B<xref linkend="sect_CID_3207" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8393dd02-d091-49f9-ae8e-4ad3869e07c4">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63677996-0a50-4fa4-8e50-1e45929805be">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3352984-c0cd-438f-93f6-fbdd73f53630">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e34f70e-9126-4891-b777-1cf43e7a816f">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92ea580b-4453-485a-82bd-fb0069199e0a">EV <link xl:href="http://snomed.info/id/128954007" xl:show="new">(128954007, SCT, "Procedure phase")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ac3ea8cf-9ca8-41b3-83d1-c99722f57e57">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_914e2610-029e-4b63-bcbd-a6f8c773403d">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6dd1297b-8a36-4402-8780-c56c09c6d6dc">IFF Nuclear Imaging; XOR Row 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9cb08bad-078d-4f7a-9bd7-e4f56e46a932">D<xref linkend="sect_CID_3101" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_921ec635-c7be-4833-a4cc-ac9f960768ad">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f75792b-b994-4413-96fc-6780a1b15624">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a99054e5-19d7-4fb7-aa3e-e81dc35dcaae">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0074c2d-6887-42fa-8f10-a283f77be01d">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df526ac1-b82d-4b89-b805-938e8f4079ef">EV <link xl:href="http://snomed.info/id/128954007" xl:show="new">(128954007, SCT, "Procedure phase")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_758e8e31-7f22-4b81-8ddc-95fd63e18a4f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2f2c756f-5b4e-4cae-8662-4e7779719880">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67b2960f-5709-42b5-b7b5-83ba25ddd437"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d6d84dc4-2d89-4214-bfcc-e7608ec2296c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_347f4b18-28f5-418d-b004-62b1fca077ae">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b47e928-f054-4452-ae25-9eaead8565d8">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dac533d3-194e-48ba-b814-035bcd9911a0">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fcb7ff91-9a00-424a-8e85-8d1c2f1cdd86">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2fbf39fb-a45e-4e5a-9c3d-ba4a97c0e2f8">D<xref linkend="sect_TID_3301" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0c13998a-12f4-4659-a1fe-938617ddf156">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b3eafe7b-2345-462e-b106-9ea855b9d8fd">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5e0ba1c-066d-4037-a647-16d5c272ae84">IFF protocol changed from initial specification</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_937b0bca-8e17-4693-849c-5d2675179221"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_218d870c-ec13-4068-9e8c-5ff6600440ce">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e94b0f6d-b710-406d-b6e1-7f463923675e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75b501e3-dbb5-434b-b130-08c4d099dfb1">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4329b7a8-4149-414a-a639-a69b1d9b57d3">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8da2b98b-86ef-40f3-9c8d-19778f645420">EV <link linkend="DCM_109055" xrefstyle="select: nopage">(109055, DCM, "Protocol Stage")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b44a3686-9384-406e-ac38-8a55f7342303">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e88ff15d-62d2-4eb8-b959-ae4692629744">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bebee56e-06c0-473e-922e-80f473102200"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1775c8d0-7d36-41c6-8c76-b0947bab2d99">UNITS = DT ({stage}, UCUM, "stage")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3edb905a-2d14-4aa8-87e9-bdc425d5d507">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad70c2a5-1232-4b64-b7f8-982825d1ff7e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee3b4e3a-014f-412d-9461-a8a24ec56a47">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b78e02e-2ac7-4497-b977-f84e50bbf066">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6395884b-0ecd-4f50-886a-8e6cd2c9ae9f">D<xref linkend="sect_TID_3304" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e62ab25b-3d61-4cba-b88e-ff9d2467e9e7">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_66ba7d32-4688-4492-9cbd-c98ca74049aa">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_083e3e73-7b40-4646-b532-1f088002fa45"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_109f03ff-4521-4652-9ee4-0ccf5d0a1c01"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fef39f2b-08a5-4a65-ae39-cbe5c3a9eea5">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7c8a757-8119-418a-95ea-034233e814a5">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2864bdcb-46d9-4863-ab8f-624c56dc29d3">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea2221e6-dc7d-431c-92ca-bc6fac83987e">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b76ced8-7bb7-4055-bdbc-2fa6e7aef2dc">D<xref linkend="sect_TID_3307" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_49aca18d-6da2-4d3b-8d76-b7ef98fad589">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5ace559b-ab99-4901-8442-3969531534ae">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc11c8c3-ddb2-4e63-8357-522e7edf77eb">IFF Nuclear or PET Imaging</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_300b58a2-58d6-4794-8b93-c7e1116c4840"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3bd82b0-e267-4769-ac5a-6f40d2a0ea85">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_68aa8871-2db4-40ca-a423-23aeb132f6e7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cfe5ce05-f9d0-4885-8f56-d9db8b36fe06">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1cd45039-455d-48b3-a2db-6200868156a1">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd7a5677-8b3b-44d3-a452-b8a00ecc6a97">D<xref linkend="sect_TID_3309" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_39335758-f984-4eef-a9da-8216cb897dae">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8338233f-5c04-44aa-bf33-2bcc25f5d929">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5894750e-0677-4993-8163-829664e32238">IFF Echocardiography Imaging</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da4f0b38-59c5-4a89-937b-de95e81e5825"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_a61fa5c0-cf38-42cb-85d8-9ac6c9d56c15">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5aaa3194-20e1-438d-9a17-3701e6b025f7">Row 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9dbe6400-aef9-4810-9459-05fc8a6a0651">The Container shall have a specific Content Item Observation DateTime (0040,A032) Attribute to indicate the time at which the phase began.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3304" status="3" xml:id="sect_TID_3304">
                <title>Stress Test Measurement Group</title>
                <para xml:id="para_fa3d8bf7-4961-4009-94c1-a620edad0612">Each instance of the Stress Test Measurement Group represents a group of data elements acquired at approximately the same instant, and conventionally rendered as row in a tabular presentation. It is typically generated during the Stress study whenever a time interval elapses (for example, every minute of the phase), when a technician observes data worth capturing, or when measurements exceed a given range.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4af37e5c-93f9-4a94-bdd8-7bff310abcb8">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_01f6c57a-ac2d-4542-9954-5b3802a28a8f">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_6e939f0f-13b6-4aee-8b2e-1f8bb0a53617">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3304" rules="all" xml:id="table_TID_3304">
                    <caption>Stress Test Measurement Group</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c1a958aa-1153-41d8-9526-b0cb9bc3f5f6"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c128b010-b31f-4fd7-bd03-9571f0c1d0ec">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d6a4ec64-6d65-4caf-bd90-c2133850545f">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_621621bd-b13f-45e5-aa80-103d53502f7b">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_faed8b3f-14fa-436b-ad99-2eb1a1cdb77c">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dac4c007-2149-4f43-9970-47dc405b5a98">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ffdac16-a27a-48be-a01c-cf1334df4bff">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dcd9fd08-d990-4542-a20f-3641483db587">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0ab2a5d8-916c-4e19-bdc5-29f00f02fdfe">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c59925c5-d78f-4e3c-8465-bd31aef122ac">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37275a25-f68f-4719-a272-8a7e3cfb4791"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c9a0a04-cad6-443c-807d-1a5d4640c458"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c4bd891-7b82-4044-9b44-f014ebeb6893">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_01b61737-51b9-4396-979c-a41a0a59340e">DT <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_10696be1-1232-474a-ba7b-a728c715ea17">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a971a4a6-3973-46c7-87d7-6bccff0f5c35">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98b27065-3127-4b95-ab82-0af62ca8e6f0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67da349e-58ab-4b65-a145-8d90dcb08b91"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73bcd75c-affc-403e-8800-21c5db2caf41">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_423783b0-d300-48b6-a6ee-fd23262503f9">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d204f527-520c-4ceb-8da3-072b2cb93086">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d7bc9ca-94d8-49a9-8ab6-9d11ff56b61c">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6f24fb9-1b8d-4770-92fa-116e70248242">DT <link xl:href="http://snomed.info/id/252131008" xl:show="new">(252131008, SCT, "Time since start of study")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aa394fc7-9ad8-4f05-9bd9-021e3b30add8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ac8d4a75-73ed-4b14-a67f-f20385fedd85">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_90a728a0-1c07-49e6-b901-ba3938abcdc4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aab4e0c5-2eed-43c7-928c-c0a6839bd668">UNITS = DT (min, UCUM, "min")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22044777-1d48-4080-8356-08bf99f749ce">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b839bedd-f93e-4609-9f95-4eb11cd54b76">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e44c5245-3845-44dc-a208-8c5a375855ba">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d47c63eb-4a6a-47a2-b389-fcda908bc200">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0671a8de-c4fb-4e62-ad05-096426a15dce">DT <link linkend="DCM_122710" xrefstyle="select: nopage">(122710, DCM, "Time since start of stage")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b72888e0-1c64-4314-8279-50e425f338b3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_261891ef-fa85-4c1d-abfa-93ad915f3a43">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a17643e5-1169-48d8-964f-22f2be094699"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c06f598d-2fc2-4a3c-a453-661cb71a9485">UNITS = DT (min, UCUM, "min")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ccef03e7-c259-4ecf-ae45-889d25282fcc">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f13596e-d515-4c1d-9600-e0160a6562a5">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ebb197e-ddf5-4256-ae5a-bf7ccf52b74e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3872c2e-a7f8-4694-8e9d-12fa2904cbdd">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bed2548c-e560-4453-9504-9e87e56ac05e">DT <link linkend="DCM_122702" xrefstyle="select: nopage">(122702, DCM, "Treadmill speed")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7fdf9fd-2516-41bb-bdf6-899430eca865">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_12f98bd9-030d-4465-88ea-7def468bcfe0">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c39bab8a-56c8-4eb1-a13a-d696de6217cd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82a6f090-460a-4141-a7a7-f6f7f7b3a178">UNITS = D<xref linkend="sect_CID_3212" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6d4fe3d-c561-4871-bc9d-76a3b9c0861a">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_312697f5-6d1e-43f1-a6be-a94ff96c1c50">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3baa30eb-49ec-4666-b1cc-cec111af08f4">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2d3a0501-1a5c-4a18-af23-4a13331f1a6f">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87061fe4-0614-472b-acdd-61ed76cf467e">DT <link linkend="DCM_122703" xrefstyle="select: nopage">(122703, DCM, "Treadmill gradient")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_34127c99-9eae-4ea2-b859-5e597eb4fb64">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3fa39540-caa0-4073-9a57-86face4484b1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_933dac60-630e-478a-80cf-6ce149a8bea2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2635cb0d-3d8d-4a38-a7c8-1f212c7b40d2">UNITS = EV (%, UCUM, "%")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_823ed5af-8b3e-4c22-83a0-12523fb9a9de">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8967e25c-0916-4483-aa3a-50d0dc84bb5e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc611741-1db5-4ad5-9950-2ee16d73a5b1">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d156a71-8598-45b9-8e89-21f4ecfee8cb">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ef930a1-df78-43b8-a2ce-6121fcd006d2">DT <link linkend="DCM_122704" xrefstyle="select: nopage">(122704, DCM, "Ergometer power")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e274b07f-4a05-4a93-ad9e-bd51c20b7c2d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e1c30774-981c-422e-9e8f-2708d214b46f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a8b7b4e-cf2e-4aa2-9d0d-06add3bdb712"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_677ed064-2965-4192-bfa9-91edd68f8c1c">UNITS = EV (W, UCUM, "Watts")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24d10d4a-0c99-4982-a268-6c79872e0606">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0861491f-b4d7-48c7-a7a5-a8d507654289">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b8d17af-a215-4eb5-a428-6bc28a2a8edc">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ae04ecc-93c6-4086-8915-000cdc3f6a78">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3017fc5b-1dfd-452b-ac41-559b31c4ccba">DT <link linkend="DCM_122709" xrefstyle="select: nopage">(122709, DCM, "Activity workload")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_da7144d5-d8db-400c-8049-2064a7e7116d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eb381794-ef8c-4a3d-9ff0-258250f291b4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c5a8289-854a-49e4-bd02-a5c3751be5b9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4cb043b1-312c-4d43-a79a-775a38b400e0">UNITS = DT ([MET], UCUM, "METS")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ab9f973-55d6-4a7e-ae18-6d2e4a340c71">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b02b6aac-99d7-4943-990b-99ecb5aa90c7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b4eb7ac-40c2-438d-9c7b-dbead8ea8e4a">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29a820f3-7077-42cb-8169-105b8fe093b6">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc9f6af8-97bd-47d2-b33f-f4510bdaf559">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_79d705ce-5a12-46ae-a60d-7521f69f267f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f4bdf72-7248-4876-807a-371e619493c1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad0acfd2-64cb-4951-a5b7-70427d3016c6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fcd709df-becc-4dd0-98be-b5aab5016029">$Measurement = DT <link linkend="DCM_122706" xrefstyle="select: nopage">(122706, DCM, "Rating of Perceived Exertion")</link>
                                </para>
                                <para xml:id="para_8be5fe61-6fec-47ab-bda4-f641bc4ac76b">$Method = B<xref linkend="sect_CID_3239" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_125c62f8-a37b-4de4-8228-d4075ae4ab0e">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a181a68-3b85-4755-953f-c4e7b77d5005">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52d20ac5-f831-4251-99f9-df2db0e73d6b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c147d372-b51a-450b-91dd-553712524833">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_76198231-92d0-47c1-9fbe-910da72418e2">DT <link linkend="DCM_122705" xrefstyle="select: nopage">(122705, DCM, "Pharmacological Stress Agent Dose Rate")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ccb43719-7c93-4339-95e9-c9ded7589633">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dc19fbc5-529f-4c53-a54e-19ef4109727a">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f172894b-0aa1-45e2-8d19-fbd4207b50c4">IFF Pharmacological Stress used</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72ee5243-c4ec-49cb-8a96-4a0eb68f7786">UNITS = EV (ug/kg/min, UCUM, "ug/kg/min")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2923a68a-221f-415e-9606-0efc153ec8e1">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f2f1b77-18fc-446c-881c-3a333359a9fa">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b191c206-0e7f-4568-98b3-2804baff477c">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee85f11b-7848-4cb9-ba33-f93d693fd053">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08d98a95-d287-4d7d-9c58-7f219f52d0ab">D<xref linkend="sect_TID_3106" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_08e938fa-0d1b-4315-8492-af1ea4c2ef9f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9486f6d2-413c-4c15-9805-62544e7a4e09">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5fc8a6f8-bbab-4fda-b581-f3f83033a663"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c549c81f-fde0-4c0f-8255-406fc7350a06"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3e497bd-7793-4e2a-a35e-97c923f0a7dc">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7b4f9ab-146b-4b67-8a2a-a873fdcf14b8">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1f2fc3c1-174b-4702-9ac7-be489bf3359e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c73867b4-433c-4bbd-85ad-c4736b61f947">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8eea8d9-0aad-4de8-8e11-f0f71b228548">EV <link xl:href="http://loinc.org/8867-4/" xl:show="new">(8867-4, LN, "Heart Rate")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_44279121-bdf8-437c-90b8-8f75749b8642">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e73e8b41-9760-401b-bc14-75b00416b966">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2332c120-31bd-4fae-aa3b-b76b4f894b8c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_612c185e-70cb-4d5c-9a32-fa2eba6b9d6d">UNITS = EV ({H.B.}/min, UCUM, "BPM")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39ed38e0-49cf-4b5b-b7ed-e67abe145c2b">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d972cd15-02a2-4960-8035-a55fcdbca41c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6799616b-142f-4c44-b149-99374253e155">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a29db86-b8bd-4f4a-850d-1ca62de5bd04">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5bf1d58c-9b4b-4876-b70e-b6663296233a">EV <link xl:href="http://snomed.info/id/271649006" xl:show="new">(271649006, SCT, "Systolic Blood Pressure")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f09312a8-01f6-42fa-b228-b9de58fe88c9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_980b9e0b-7e80-424e-b5e8-5b107334ca88">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eef59e02-b9d6-47ff-ac91-834cc80ecbf4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4db9fe50-e41e-409d-91b6-39a269f3a6a2">UNITS = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de674168-d4d8-4768-9b71-80fe5618676a">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8cc2c176-cb6e-4a13-a111-ec75a1577175">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c153fc1-6233-410b-a9d2-acbc71a50c99">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_235e7f1a-e789-4a50-a360-d6a83aa495a9">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4404317-0699-4587-bd67-07813107fe1d">EV <link xl:href="http://snomed.info/id/271650006" xl:show="new">(271650006, SCT, "Diastolic Blood Pressure")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3af6d4f6-32c5-4dbb-99d1-b8bdea233829">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ea27fdd6-fd6e-4906-9236-7f3b30c34816">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd36b3e7-74ba-4f6b-891d-1a419285e739"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5428adc-534f-44af-9053-f4c3a7777ce0">UNITS = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96523572-bcd4-4de6-a21c-293f3da85f85">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92caddf5-79df-4c66-8092-27e5e0164462">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ab82cc2-31d1-463a-aac4-2d04fef8a2e0">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0025af9f-4a01-45f0-bb20-55415aa6d715">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_681a31f7-7c46-4c44-a974-9f631ebdd847">DT <link linkend="DCM_122707" xrefstyle="select: nopage">(122707, DCM, "Number of Ectopic Beats")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c1135969-39df-486b-a7af-9bbac94a534a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b8ca46bf-0753-41b5-8dae-792146cf9deb">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5905206b-c2ec-462d-90cf-4745f8dd379e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0c8df16-fae2-49c0-a30c-f5caf6bdd7cb">UNITS = EV ({beats}, UCUM, "beats")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a852bd35-b184-4e87-9a49-e0bb41cace28">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb505bb0-867c-4f6a-a080-6475ab80f7c0">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75664401-be4c-4ddd-a3f1-7a5e25e1dead">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f7af7809-81ee-4efb-b25f-36cd18f109b8">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_991bec89-2e92-4d17-b470-4acc1aede1f5">DT <link xl:href="http://snomed.info/id/260867005" xl:show="new">(260867005, SCT, "Period of collection")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc58c287-9b0c-43bd-8f9b-6b836cb42212">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7b91e87c-c94e-48b7-8947-4651a894afc8">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81be0989-2ef7-4962-9257-b565c238b819"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ab61774-8475-4cf6-9728-c88c0faa930d">UNITS = DT (min, UCUM, "min")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c198ec9-63c8-46ea-ac1e-ca3b0693fa84">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_475b6403-1ee4-4501-8f05-d7b760e48ce7">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_173fe6ba-09e6-45e0-88b5-08b27be4ec07">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a1b68aa-b910-4cc1-ab88-9bfb51dda704">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1da8ef3-a25b-4fc9-8917-e91a198d2cda">EV <link xl:href="http://snomed.info/id/116676008" xl:show="new">(116676008, SCT, "Associated Morphology")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8002544f-9550-4265-be58-b224760d6b88">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_629c7431-8c57-482d-a5da-ce321630c7c8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17569135-8abe-497b-9843-b50f90117ab4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d4a3b37b-5b7e-43e7-932f-fd0d596b9ba8">B<xref linkend="sect_CID_3234" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e5c0143-aa6b-44e2-9f8d-f5f440e8401e">17</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ff6fdc7-53de-44bf-8f02-e1b7602779b5">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_175a62c9-095d-4521-b527-fbbc80b6c88c">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_707932c3-f207-4b3e-8a8e-666d3b4456a4">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8731c789-d779-4d69-984d-b79c1be302a1">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7f937a91-17e2-4b31-bac9-fdff3d5577b0">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_95049cd5-2ddc-44b7-ab36-8485057b6d97">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0de3770c-a1cd-44d8-bd6a-5a59a7cd6c0a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_738b794a-2e48-4ab9-984d-b8824aea8913">$Measurement = DT <link xl:href="http://snomed.info/id/164931005" xl:show="new">(164931005, SCT, "ST Elevation")</link>
                                </para>
                                <para xml:id="para_f5f6f794-0aff-4335-8712-c88f7495e3b9">$Units = DT (mV, UCUM, "mV")</para>
                                <para xml:id="para_8fcbe267-22f9-4d42-ae42-f8f20b2274bc">$TargetSite = D<xref linkend="sect_CID_3001" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_18eaa8f9-060f-4474-8c65-2274c5b2d128">18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b3f09b1-2e5d-4519-97cd-9c6dfa98bbd3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48f93b61-bd6a-4f52-a669-d89a30217414">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f06420fc-9500-4f25-892f-8331d5694b3d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5bdc62a5-1826-4d99-8879-9510f5827a1c">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cd8420a0-6a55-44a9-8cdf-de9d5e04bd80">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fcfb59ad-aedb-4af7-8d79-371ccfb8b37d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58c86bb5-1201-44f3-a2fa-f1972ce64b52"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c5f033b-2f72-44f7-8eab-640818cbd2de">$Measurement = DT <link xl:href="http://snomed.info/id/429622005" xl:show="new">(429622005, SCT, "ST Depression")</link>
                                </para>
                                <para xml:id="para_ae90d296-42ca-4f3c-b84f-682a9bf9aca9">$Units = DT (mV, UCUM, "mV")</para>
                                <para xml:id="para_ee81b8eb-06ed-465c-a3e6-424b8eb1d438">$TargetSite = D<xref linkend="sect_CID_3001" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc5c2c05-5143-4387-a23d-671295bd3d82">19</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4df44558-1b20-410b-8957-045e6121d5df">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f05c66a-bbae-4e38-8ac4-b64d4a5d72d9">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_287f03e3-912d-4802-a380-1713f091b374">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a24416f3-493e-4102-83c0-3132b4f5b3b4">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a66709a-5154-4ecd-9edc-8798c2fe70a6">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1871204b-f7db-4672-b2c6-6c7d3f6b5baf">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6db80462-c91c-4467-9d2f-bf97c91ae035"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d30e58c-4ae8-4c59-94c8-cc25394fbacd">$Measurement = D<xref linkend="sect_CID_3228" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_d5179807-a3b8-448a-96d0-5873a090f57b">$Units = DT (ms, UCUM, "ms")</para>
                                <para xml:id="para_f196218e-2515-4725-adde-641774b06f95">$TargetSite = D<xref linkend="sect_CID_3001" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_3c85740e-20e1-4f2d-b41a-3a5826bc8f3f"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e4373b8-8d62-48ef-9f74-f08c7ecb3cd3">20</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eafcecfe-c653-45f1-a72b-b7cfb239260f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e367b4a4-83ba-4d71-bb84-85aaa977db2d">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ca1e219-44be-4fea-ba2a-846b1eaa8f87">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42576a91-22e8-4c86-a56a-5e2804a027c2">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7d6dc1c4-2727-4d5a-9e30-589f6fd009c8">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c94b3695-6fba-4347-84a6-f50f9dcfe573">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_272ad6c0-ae96-4211-981e-461489558a20"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6126208-42b4-4ea8-a7f4-b3f5832181fc">$Measurement = D<xref linkend="sect_CID_3227" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_d434ecaa-e75d-43db-bb42-c64d8dc24b0b">$Units = DT (ms, UCUM, "ms")</para>
                                <para xml:id="para_30fd6956-3d93-4d9d-9c11-a68c8d279eca">$TargetSite = D<xref linkend="sect_CID_3001" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_34ecd79d-e64f-4a4f-9e78-b8b1077b6ed9">$Equation = D<xref linkend="sect_CID_3678" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_a942b1c9-f4ad-4c73-a988-e9533397ba86"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_038c67dc-0812-48df-900b-ee6db935d6f8">21</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_44b966a3-9e63-49b8-837a-0417c225fcd7">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c8a07ad-6c17-4576-aef1-0bf8e7ddffe7">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_875f8334-9e32-40db-ad30-09b5c528ff50">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35905c1f-baeb-4fef-819d-3d337c259007">DT (2:16000, MDC, "RR Interval for QTc")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c72e11ab-0847-482e-a91a-882aa8d5f4f9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bdace920-8494-434a-a057-4b298e967aed">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50ce3fc6-2e12-4816-99ec-ff0933851e53"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cbba79b2-f305-499b-9ca3-0153ce0a2b9e">UNITS = DT (ms, UCUM, "ms")</para>
                                <para xml:id="para_64ba030a-dbb4-4291-ae03-d030a0326724"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26f564e5-76d0-4748-bddc-11fd71ef81b6">22</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79951b80-1dba-401e-a7e5-d0a7f2831e4c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4be56282-0bd5-4490-87e8-00d308929fe5">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8514c8dd-56fe-434b-be7b-8f8e27429985">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f4aa8ca-4c39-44f3-a0dd-7f69d5079932">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d71ecfce-c43e-4c70-aabf-b27dad0e4173">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_983b481a-4723-47c2-a086-dd5406e3f9d5">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a810dcda-eca2-4758-9a5b-b29705c3897f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88527919-5fee-4b8e-82af-636f728ab12e">$Measurement = D<xref linkend="sect_CID_3229" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_fcc028b7-f0de-4698-8a1a-9a7077a071dc">$Units = DT (deg, UCUM, "deg")</para>
                                <para xml:id="para_54c94aea-93d5-43f1-8a12-d2f7cc5c7c99"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d2e69124-6366-417a-ba7d-ee3788e6cbce">23</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a4bdd2b-1213-47b7-bcff-d8f98489e295">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e0e3bad-19a7-4f5a-9319-73093f8f2d29">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99684f0c-bbbd-40ae-a678-8fc3d7415e30">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30914f63-5d82-4299-a8ee-92c51ee1efbf">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bd9c35dd-ca20-406a-8696-bad5beefdef6">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_04830c7b-f7d2-4ed2-925d-4f862ee0f924">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2226dc9b-d795-4061-af33-2e8cd0916f6a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c582505-37d9-437a-9d29-8a99dd4dc379">$Measurement = D<xref linkend="sect_CID_3526" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_c333c918-6bdc-45b3-b2c8-609536ea3f7c">$Units = EV (%, UCUM, "%")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c1c04b3-1845-418f-ab0d-de40484f692d">24</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0107945f-1617-4703-a051-405757e699e7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca03817b-6191-4ad5-9dfa-4a6251b034fa">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cdb24870-aaa8-423a-a939-d8513cc8aa04">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_946285e9-36bb-478a-b806-f7956bc0b0ed">DT <link linkend="DCM_122708" xrefstyle="select: nopage">(122708, DCM, "Double Product")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7d3bd3c-079e-428c-8446-53421156671b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7116d1be-0e8c-481b-8eba-641d1c497d25">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e0dfbfcd-1bcc-4018-b2f5-ead6dc751046"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e7722d6-7f05-4622-af27-f476ee73cf71">UNITS = DT (mm[Hg].{H.B.}/min, UCUM, "mmHg.BPM")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8165c12-ebdf-4466-bcd5-7bc589ef0ecb">25</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6dcdb876-5ce6-43af-852e-188f419be95a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6fb249e6-46e5-4877-b672-15a0bd40c5af">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ceb2b28-88e2-405f-8a64-43940cf17529">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4efb9ce4-5e0c-4f08-a422-b577c3f87a67">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_546bf720-f206-462d-97a3-1abe89af90b5">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fd4c2891-f35e-4224-9de2-65d691de8537">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_71760982-1359-4893-94fb-9fb78731088c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d0759df-97a8-4147-9f23-999e4a14b82e">D<xref linkend="sect_CID_3220" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb9179d9-b90a-40ad-a3d7-bd144416a962">26</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d6f538d-edf5-435d-a523-7ecb017fb8af">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f4c82b3-27b7-4a20-a544-cb1eed0e87e8">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_796ef6d3-4eb0-49b8-a4be-6d500647e3ae">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8eb59a1b-ace8-4210-a07e-fe193debcdc6">EV <link xl:href="http://snomed.info/id/271921002" xl:show="new">(271921002, SCT, "ECG Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_64b45d47-404c-400f-8f65-69c435b19f8b">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8dfd1ea3-8ca5-46d4-8a58-21608fcaf284">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec061924-a397-4dba-998f-4eed66964e13"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b48b39eb-a0e1-4284-9406-04c5340a494b">D<xref linkend="sect_CID_3230" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b88eca99-1b45-42c9-95f9-33ba4f9909cf">27</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d26afe08-c1e3-454f-a112-29af56a9afaf">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d15f2e6-518f-403d-af87-afe0b5883cb6">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e27dbe6-caa9-4adc-a910-54e66f67f05b">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa1e5917-19b9-4777-b07a-615594961d47">EV <link linkend="DCM_121106" xrefstyle="select: nopage">(121106, DCM, "Comment")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c0882cde-bb84-4061-9fbe-597d14b80d11">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fef46102-33bc-4345-851d-2965604bb3dc">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd162fee-f4a2-442a-ae41-ce4a7367d375"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd10c650-71db-4ec0-85df-95119adbeae5"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_f9b68bc5-df3c-4f64-8ee6-b0f0685a1a13">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8bff13bc-6b6e-4c75-802d-5ae8a8c1cd61">Row 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b0f6081-0cc2-4b33-9894-770ab35a2cfc">The Container shall have a specific Content Item Observation DateTime (0040,A032) Attribute to indicate the time at which the measurements were made.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67265d6b-f023-4a7a-b422-81ac2f30d799">Row 10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c88697c9-9dbf-4240-83bb-0ba7928e28cf">Included <xref linkend="sect_TID_3106" xrefstyle="select: labelnumber quotedtitle nopage"/> allows the recording of test medications other than the Pharmacological Stress Agent identified in <xref linkend="sect_TID_3301" xrefstyle="select: labelnumber quotedtitle nopage"/>.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3eb13aed-0577-4d78-a2de-c22015777572">Rows 17, 18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_68ad2ba1-f1fc-4c8d-a0b3-f34d6478651c">ECG ST elevation/depression is measured in units of mV, but is conventionally reported in units of mm, based on strip recordings with scaling of 100 uV/mm. The display application should render these measurements in units meaningful to the user.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17718205-d5a3-47e4-8f88-b9562e46b96f">Row 19</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_239fcae6-207f-4c8d-86e8-c06427a87c44">Note that the MDC codes for "per lead" measurements specified in <xref linkend="sect_CID_3228" xrefstyle="select: labelnumber quotedtitle nopage"/> are base codes for post-coordination with lead identifiers conveyed in the Target Site modifier in <xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>. MDC also defines pre-coordinated codes that include both the measurement and the lead, which may be used in this row.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ceb81111-1cee-42f7-b59b-b059427c63b9">Row 20</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_653fc8a8-4749-413d-ba87-67f3d4e3f29d">Note that the MDC code for "QTc interval per lead" specified in <xref linkend="sect_CID_3227" xrefstyle="select: labelnumber quotedtitle nopage"/> is a base code for post-coordination with lead identifiers conveyed in the Target Site modifier in <xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>. MDC also defines pre-coordinated codes that include both the measurement and the lead, which may be used in this row.</para>
                                <para xml:id="para_faf95d2e-3ec1-4a82-a80f-be25e11f8ba7">Note that <xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/> enables the encoding of a non-standard correction algorithm, either as a local code, or as a TEXT Method Citation (see <xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/> Row 12).</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce6f3c37-cff3-4300-96c1-8606d9b86d94">Row 21</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38a690cf-fce7-41d1-81c6-997b02dd331b">R-R interval used for QT correction algorithm</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7feaeab-963e-4301-b62e-d8a14ab3ff40">Row 22</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a5204a4-c715-4df6-9b38-42d14b456a10">Recommended range for ECG axis measurements is -90° to +270°</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3307" status="3" xml:id="sect_TID_3307">
                <title>NM/PET Perfusion Measurement Group</title>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_6fa9f39d-1c60-4847-89b5-fb795490ad5a">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_43a98cd5-0e36-46c6-b99e-fc40f3d92910">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_865979a1-cebb-4544-87de-878477578412">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3307" rules="all" xml:id="table_TID_3307">
                    <caption>NM/PET Perfusion Measurement Group</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c8a88b1d-3d2d-4b74-adef-473edb60a304"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_932fdc36-9b12-43f9-ae02-42bbfb249203">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3562aebe-d6c0-44af-a3ec-b818d33ccae0">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f91e8717-105e-4abe-986f-db245c649fa4">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e1196bec-4e19-43d3-a78b-607772ca30b4">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_61a4345e-7b10-40e4-8107-5372d6ef78ef">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3309399b-c683-4cbf-b46a-ac03e13804eb">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_458465fb-0558-488b-8e92-d00837a3ccd7">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0227415f-2bfa-42af-ba2b-df72378a1770">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a56f61d3-736d-47ac-9fd6-1f8c57b3bd20">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ced5da1-e88a-4fcd-bfcb-2fc142e420c0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4e94319-d0b3-41f7-8668-62a27d0065d0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39b64f33-c642-4198-8b16-6e2b6f7ecf62">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5390d95b-8a89-425b-94d1-1c9a553e8607">DT <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_978ce402-4587-4f26-a80c-1a95ea21b2bd">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e23cd3fb-6a06-4568-b391-346e567fab25">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf79344c-fd67-4802-8387-9071858b21de"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_32a86007-1698-4eef-a57e-83160bc3b499"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5e32f25-6407-4e7f-a7ba-009d7b0cd4dd">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e0520b08-0f5e-4b08-aedc-4c0ae4f6f948">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f95def3c-e073-4f90-8cba-8b601ce6cd76">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73d39b6a-2612-447c-9fe3-5c42d438a401">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4c93aed-0f9b-4834-a6ae-8c2cb1247aec">EV <link linkend="DCM_121058" xrefstyle="select: nopage">(121058, DCM, "Procedure reported")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ffa99887-ad18-4d48-bc9c-53abf07b4d8a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_25296511-4a47-4486-a16a-1d549ff13f20">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61b5f7b1-32b1-4342-be59-a6fb9dd08ff5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48044048-52cc-4947-91f1-f49d76998f05">B<xref linkend="sect_CID_3108" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2fcbef97-c5af-44a5-b68a-78f0ff7f207e">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e1bd6bfb-1873-439f-9e4a-b936b86c614d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec44f1aa-477c-405c-8e5c-7a345e71365b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd9977e1-6d9d-4f94-b53c-1d1f76b0eff1">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ffe8da8d-1f15-451b-9ad8-62f6aa54172a">EV <link xl:href="http://snomed.info/id/349358000" xl:show="new">(349358000, SCT, "Radiopharmaceutical agent")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a085db9b-6a2c-49dc-bab3-ec93350f3dd0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_99e7b4f2-29aa-4e34-88d5-c7e4f623154c">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_973e5812-7f26-45fc-ba3c-03551ed48313"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2964b5f0-0963-4a50-abb7-a13c68f55b12">D<xref linkend="sect_CID_3111" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf467854-aa37-4b12-a9dc-815c6e937af6">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9e9ad85-f8b9-4363-9eb0-40bb38517276">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1634e33d-630a-46fe-a901-5583c99b2af6">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e27bbf21-acdc-49b0-b69f-fb80d9d176b7">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e3729fc-e438-43c2-b1d0-0d675e992fa9">EV <link linkend="DCM_123006" xrefstyle="select: nopage">(123006, DCM, "Radionuclide Total Dose")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c099b3f7-d757-4e54-8cb5-a03cd4fa2e69">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9c03c69f-f68b-4c57-9519-99a814308ca2">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_901dfe8c-3dfe-4832-bfaa-216d58d54d17"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7585cba6-1fe7-4c30-a866-54d33e906067">D<xref linkend="sect_CID_3083" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca6c86f1-1d0e-47e7-9198-5d363765428c">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_adfe27b8-a473-47f9-a605-6866870256a6">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c061332-cf29-424b-a223-34cd9749244e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee64581e-742c-40ac-b77f-e1ac61fd6ef0">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b7bc394-2cdd-4559-a7cf-7ac0fa521b39">EV <link linkend="DCM_123003" xrefstyle="select: nopage">(123003, DCM, "Radiopharmaceutical Start DateTime")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_af1ba234-70df-4f21-8904-c0678a77881b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eb9ebfdf-5a28-46cd-9b83-2555411a2ecb">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e2fd223-ef08-461b-b6b2-15293166d158"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8f1f3b4-d941-42d3-b74b-bb3363d45a21"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_225323bf-dd5e-4be7-ac9b-f5e8dd7045cb">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37e09922-8967-4cda-a686-3d28c919e5d9">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ae034e5-f292-4a5c-8f3c-5629ab4dd264">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_261f52c5-c70f-4332-b7f3-c8d358a79f74">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f21552b-3ca8-4c1c-be69-8463a928cc2e">DT <link linkend="DCM_122711" xrefstyle="select: nopage">(122711, DCM, "Exercise duration after stress agent injection")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4f41dc19-dae0-4323-9e70-f0ef11c58639">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c2a4c76b-4eab-4828-8bf1-c45ecef40aa3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bfa8892b-2d80-4282-a12a-680465831720"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a0bacb3-0987-4aac-8048-43d6091164e5">UNITS = DT (min, UCUM, "min")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46493ffd-d377-4fba-ac93-0dd36c0ad0b2">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b95469c-639b-473f-85d5-debd567b76b7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_78d72904-1193-4e47-8baf-befdcbf49201">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d95917b1-0789-4ade-80f8-e2fad6fb1811">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_960ad012-5fab-4031-92b4-8fa102a14e37">EV <link linkend="DCM_122712" xrefstyle="select: nopage">(122712, DCM, "Imaging Start DateTime")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ed20fc47-fa24-49fc-862a-4338b1f7a18f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f1ebcdb1-ee77-415a-854b-016e98addd2e">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f159f364-262b-49e7-92b6-588178d90c91"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_043301c5-55c8-4211-8da6-9d6a1a8c1f12"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d4cb02d-6312-4305-a7ca-47f1d94330d9">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de6770eb-edf1-4067-a180-8a78e9e3113a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6a2e80c-a63b-49fc-909b-6ed40d64049e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f710cfb4-342c-4ac6-8ff0-b7d9ce58c438">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa595056-1a00-4333-b43a-98b75b59b6ba">EV <link linkend="DCM_122713" xrefstyle="select: nopage">(122713, DCM, "Attenuation correction")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_073fd5e0-b232-4bb8-88bf-e4a072afa29a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_302e6fa2-3fdb-4985-a56f-c773ef437847">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04fbffea-88d3-4fc4-a725-bcd6ef206cd1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d0975ac-d2e6-4bc9-9d76-45364564366e">B<xref linkend="sect_CID_3112" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e90c443-1a16-410e-8b5d-d166741fa9b9">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_756a3451-5b30-4c01-b77d-b0ff89dbc539">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da264bb9-a257-4130-9b9e-c9ce08081ce1">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5207ee0-df18-4f2a-a184-9ec2486aab5a">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c29ea18-fe23-489b-9784-d68952e38101">EV <link linkend="DCM_111001" xrefstyle="select: nopage">(111001, DCM, "Algorithm Name")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5406716a-6567-49e7-8ade-2afbbb4cfd6e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b5e2cc27-21e3-4640-8eb8-462da169c105">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5c9e411-c6ec-41c7-aa75-88f22ebc8c64"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e7b6ee8-11d6-4fb0-ad51-1e3a2a00c34e">B<xref linkend="sect_CID_3117" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bfdc8e9f-8034-4b59-8c5d-3d70a1e3c4ef">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d05981d-4613-4123-8d71-7a9d8c751e9d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4fbe4a2a-4f8a-480f-b994-e5cbe3a82554">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7450184e-9183-49a0-99e5-89e8be56beb6">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e13fdea-7ad3-4829-9f95-32c0abecdde9">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f8601bfe-25de-4c4d-896b-585aed3bea72">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b7c83a69-14f8-4129-bb9a-a086d25dab15">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3fc84c80-22c5-4ab2-a62a-77106008a0af"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_965cc884-04cb-4d58-bcc7-fb3e7e08b1d9">B<xref linkend="sect_CID_3113" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_905dda21-0e7c-4e5c-8e9c-40b1f55bde0f">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d4dfce3-5d72-48a2-867d-cc46b769f7eb">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b957522d-cb47-41a7-b004-4f9d50546784">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_34b03939-9e6a-4c9b-8f81-84c0e91c3bd0">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35863174-f500-4c04-8428-1a43dc81b5f2">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1bd5331c-12fa-431d-a9e6-2aa7012fccd4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b28fe899-4a82-4676-bad6-805ae2d2bc63">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4a70992-ef84-4595-a93e-e8e6850b0a28"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d29a5d0-71ab-44ac-b262-8e0040eb2e91">B<xref linkend="sect_CID_3717" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a97f2c1a-8a99-40d0-9045-c65bcad36126">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b4f1bbc-64a1-4d8e-afca-27fd09111c59">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2adf6c16-c1c1-457d-a164-8a0aaccf1ae3">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13d5c59f-7b01-42db-a50a-496c9ed208ae">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1567c766-de47-460d-ab10-54cb1bb7027e">EV <link linkend="DCM_112025" xrefstyle="select: nopage">(112025, DCM, "Size Descriptor")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3eab2955-f4db-48ea-be33-d2323a82f70b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f72bc368-439b-4e70-94d2-fc8f4a1ec37a">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5cbb1e5-cb07-45c3-8ead-53622225e61a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_34ee6125-fd3d-4294-bce3-f548ff768623">B<xref linkend="sect_CID_252" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd36b957-0b92-4e08-9bc4-47dcf1f55d03">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_32a3c78b-9424-4c60-82b2-711b01866d1a">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca83de1a-d935-4216-948f-d7a4668838eb">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8c98b1f-dcd5-4fed-9f4e-32452e7c52c0">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2170d7ad-c9b5-45fb-bead-7ef254c49113">EV <link xl:href="http://snomed.info/id/246112005" xl:show="new">(246112005, SCT, "Severity")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0c5dc418-b230-43ee-9640-def860aa71c3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d5545ca3-0667-4bdf-bd70-36d2c64d4629">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_528db194-cbb7-4b66-ba73-fb07ea39fb06"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_47fae1bd-e7f9-4195-950b-093fa7ac4151">B<xref linkend="sect_CID_3716" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ef21119-5ff2-4985-aff8-fbc570ede868">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a608d7e7-fd4f-468f-9d07-af2e6dff7f55">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1806d726-a40e-4185-b2e3-781805aac65a">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_23d041f9-a8c0-4997-99c0-ef6dd784266a">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_01ef89bb-d192-49de-a344-4a76924095cc">EV <link xl:href="http://snomed.info/id/250907009" xl:show="new">(250907009, SCT, "Left Ventricular Function")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c98e65cd-5101-4e0c-ad73-9b489f43508d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7e74f309-bdcb-4f8a-a82a-8bfbb64ba6e8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a03c899-7bf3-497b-b4ca-6c4ab9c0d6ff"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_678af278-8360-4439-ac35-8f8ff8c243a2">B<xref linkend="sect_CID_3119" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_440e8529-7514-444e-81d1-498c5f2aeaba">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_963fc0a2-ab69-4ecd-8a93-8e0250dc25f3">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1024b5b2-a6b7-45e9-a4af-9128139c854c">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_49f73ef6-9ead-4d38-8905-a9b93f3b5c14">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57841c22-36af-43de-8115-f2ae9e959aae">EV <link xl:href="http://snomed.info/id/246112005" xl:show="new">(246112005, SCT, "Severity")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8e5933f6-d828-4b07-a96a-5e150b0fe6f3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7ed1c279-f64e-45e7-84b8-0475a548fe7c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6acc2639-7942-4a73-8441-be7238b152e1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d48bc90-c790-4a05-b0d5-869db5be7d91">B<xref linkend="sect_CID_3716" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be27731f-43d4-4bfb-a77e-5ec26ac51c92">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb46556f-dc51-476d-841f-a96e1556e18f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3e5f94b-a42c-4ec2-a49f-caf6afe8291a">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_398e5fb7-a813-402f-a229-961a43da12fd">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ef0f04f-c842-48b8-a50a-893d228e4b8e">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_521b2306-643f-4496-8daa-d31faa8c4160">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0a7fe551-aa79-42bb-88fe-1440b2d370d6">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f14b6217-edee-41fb-b618-7a5401fd72f1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22ebaaa7-9722-4eb8-b605-b28f05fbeaf1">$Measurement = EV <link xl:href="http://loinc.org/10230-1/" xl:show="new">(10230-1, LN, "LV Ejection Fraction")</link>
                                </para>
                                <para xml:id="para_d02fb984-8fdc-4258-bab6-b37a4f642e28">$Units = EV (%, UCUM, "%")</para>
                                <para xml:id="para_26a44043-cdb3-4b7a-91c0-1ec04398b2d3">$Derivation = DT <link xl:href="http://snomed.info/id/258090004" xl:show="new">(258090004, SCT, "Calculated")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5302332-0d1a-45f7-977e-f3d02fa3e815">17</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a6c2fe0-1b8f-47ce-bda6-7ffdec36a14d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d153852-7f9f-42d5-8387-d5a1ce738732">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0687efa8-ec95-4e33-825f-7c75092c0aa2">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1cab3894-acba-49f8-82b4-d179d86b7dc8">EV <link xl:href="http://snomed.info/id/250924003" xl:show="new">(250924003, SCT, "Left Ventricular Size")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d4b13bdc-2b74-46d5-81a0-e0bf17168547">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9de78640-13b0-4fb1-9e1d-c915e1831281">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1f03c77d-90ef-435a-9201-8315dfb0dc75"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f6e03fc-e090-4684-b027-8bde587600a9">B<xref linkend="sect_CID_3122" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ce39b71-7371-464a-9a83-4e31b8e1c217">18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3304ac89-ebea-41bf-8265-d8a5e7e8f0ca">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75571455-3ab3-4a9a-aa5f-5ecbce52d887">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f955102-9260-4dfe-bce3-dec4429fda14">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_248ae932-c22f-4e8e-97ab-2fba7cb4268c">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b32fca1b-622e-4b36-894e-5e5b8dce9eb9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0698dd6d-3194-48b5-9fbc-359dab4b4213">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eace62c3-9af8-4d4f-892e-77863173cd07"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a42f9c9e-30f1-45b7-8d4b-7aeebd600d4a">$Measurement = EV <link xl:href="http://loinc.org/8821-1/" xl:show="new">(8821-1, LN, "Left Ventricular ED Volume")</link>
                                </para>
                                <para xml:id="para_b5385af7-2b69-494f-b6f4-823e1122951a">$Units = EV (ml, UCUM, "ml")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_883e1282-3a66-40b3-bf61-7dc1d423a0ae">19</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6595f4af-4cf7-4106-af44-a9936ad46086">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67a169aa-f59c-4e31-85cd-48ba7e9ad611">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b04552ee-eed9-4c84-a89e-133336c208ad">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f988a16f-5ee8-480f-8b89-ff39cd3af859">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e9b3ba35-fe62-42fa-9ecc-72b54488c0c1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c1fd46e8-924b-4e49-a7c2-c2875f87ae08">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec0f1b1f-1e42-4cfd-a98b-a5a63466e21d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6947739-51cc-4bf2-a2d1-1ab8f7ca4201">$Measurement = EV <link xl:href="http://loinc.org/8823-7/" xl:show="new">(8823-7, LN, "Left Ventricular ES Volume")</link>
                                </para>
                                <para xml:id="para_25a71d0d-1130-4731-bd79-d77fa9a253eb">$Units = EV (ml, UCUM, "ml")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ed52b8e-a4e4-464b-bc0b-8a21429225e2">20</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_868f44f5-6333-4389-8c0a-3a4b9de8293e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e27ef10b-3cd7-444c-a846-7a1b7ee0e41e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5e86547-8c29-4401-9345-08e61231317d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4fd7eea-6618-4a04-bb55-99d3a6459d7e">D<xref linkend="sect_TID_5204" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1a4034a4-f8ff-4ed4-8272-ea3f30995081">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_753a6716-cb22-45e8-9e24-48ce54d978d3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a537b73e-71ff-4b7c-aff5-ef52022d1a19"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_07ac77f8-cbac-4311-aea3-7421ff8bf9e8">$Procedure = D<xref linkend="sect_CID_3108" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3309" status="3" xml:id="sect_TID_3309">
                <title>Stress Echo Measurement Group</title>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_7137c88b-937d-4a42-b44c-4e56078e35d8">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_344d6f99-0caa-49a9-928c-80fe83af57e3">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ffde1431-97c1-4245-88af-e71f4324d96a">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3309" rules="all" xml:id="table_TID_3309">
                    <caption>Stress Echo Measurement Group</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3d6a29db-eb2d-425d-b62c-bf238c2ffd23"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_064eed6f-9f04-4ec2-a2b6-b9868235c83d">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b30bd55-8c46-4b00-bd71-73560e8780a6">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f64551d-ddb6-43dd-ba35-1433ec7ff4c3">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_943cc216-c29f-4ce8-93e9-def772e7c76b">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_572818f7-1510-4c3b-be42-e625d9bdf39c">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_04347b61-4509-4837-918a-5b620c62b901">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3ee13f9c-fb91-4018-91e5-b2a9e9289de0">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_408613de-1227-437e-9093-4c0517debbe3">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6cd023a7-d84e-4210-a236-9a405b1dc2a0">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52fa9f05-f88c-41c7-8953-43bdda5e6d13"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0899d316-4f42-48ac-95d9-ea20f0cf05eb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6ba4df7-4433-4e80-8364-1724b6743c8a">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_552226e3-3c49-4b21-9084-c3c22270028b">DT <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8203d3a0-8864-43bd-86bf-82ad2b143b4a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b3f34298-c27f-4459-bca1-6877856aae1f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee75472c-df98-440a-bf67-0c432b4b1d18"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_abf1f00a-838d-49a4-9f57-be5d0d499a8b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f54cf894-79f7-4f60-be57-e602389bc2cd">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf38155e-12eb-4ed4-b68c-e6f3030d4bfa">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba1c9518-286f-411f-9241-0f0a0c05e113">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58cb5420-7b7b-4417-b2d0-59949f4dc08b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3ae9d6b-bcc4-4bf8-a6e0-6fb3ad770a21">EV <link linkend="DCM_121058" xrefstyle="select: nopage">(121058, DCM, "Procedure reported")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_25b8a088-2db6-4495-9ead-a1eb911cb472">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f1e00d45-2f9d-469c-9d7f-a9d1e5d8c812">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37ce911e-2231-43ba-b915-a8093e1e833d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a548d282-6982-4d9b-90cd-419c34f48f21">DT <link xl:href="http://snomed.info/id/40701008" xl:show="new">(40701008, SCT, "Echocardiography")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3980bd3a-1e49-4100-b2bf-204020b0183a">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88409c87-9168-4090-8b25-b11bf90d9266">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51824014-7e05-4954-ba39-33812c165370">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0494f58d-a4df-458c-9863-579061228086">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9dc8499d-0275-4536-af7b-b1e7f1e8caa2">D<xref linkend="sect_TID_5203" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9596e584-47d8-41ae-bb95-0e2bc56c1fa1">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_04e1fdbb-fb78-49ab-b364-20d0183e07ae">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b344886e-9acb-4e56-9b93-c407eb2605e0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a373abd-c8c6-4b17-99ad-73b315853d0e">$Measurement = D<xref linkend="sect_CID_12200" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_01381b89-793d-4bd9-a2eb-a070cce85c37">$Method = <xref linkend="sect_CID_12227" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57ff667b-50bb-4d12-bad4-e9663030270b">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c9020ca8-856c-48bc-a44a-78c53716d629">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85269d71-c305-4ec2-9a0e-25bfe541e7bf">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f7f9004-d3db-45df-a9ee-2d295d412cd7">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dde77f0d-ad78-43d0-b9cb-c50fdb3e6558">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8563c452-495d-4ecf-a16b-b63c74de0b14">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a5f2f0ed-4730-4fe3-9fc9-167c987f3d0b">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1cfeeaa-e91a-42c3-a488-a764ce766867">IF Row 3 measurement concept is in <xref linkend="sect_CID_12222" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c494da05-d665-47e9-973a-52aa0159c544">EV <link xl:href="http://snomed.info/id/87878005" xl:show="new">(87878005, SCT, "Left Ventricle")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0aa835c8-6c94-4ca9-82f9-6a59043d4c3c">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_604a71b7-107e-4c28-975e-df39a3366b63">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_19e907ea-e05b-4838-9ccb-9326b66de45e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c48a075-4035-4935-8d71-0a28ba41aa94">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1fd700d2-abe5-4499-923e-1ce6c3b9bf1f">D<xref linkend="sect_TID_5203" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ae74e772-7840-4a0e-bae6-bc05ce324aeb">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb26c06a-0bd8-4970-8db3-7446fc3c1eef">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36c5e553-2256-46a6-841c-38f77581b6bb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ac0c8d1-397a-4669-9110-ae09f354d92f">$Measurement = D<xref linkend="sect_CID_12211" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_4cd14856-ca7e-443c-8003-9480b364f480">$Method = <xref linkend="sect_CID_12227" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dfe30714-5b9a-4f13-84a4-c0a589ccd6d0">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50a80f1d-47b2-460f-9797-63315eb9018c">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e64a5264-9cd6-4921-9da6-134e05472dee">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8979028a-6985-47e8-a951-72b1409b86a7">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7fd0b2e2-bd67-4d4f-a718-507e15eb1222">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5ea880df-101c-45c9-be8a-2eced106ec14">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_16ac6ce9-84e3-425f-8afd-58b60a04c22f">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a97a0c7b-913e-4481-8f29-356966441f03">IF Row 5 measurement concept is in <xref linkend="sect_CID_12222" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_435f7028-de3a-4d2d-ada4-a7fd4d77777e">EV <link xl:href="http://snomed.info/id/34202007" xl:show="new">(34202007, SCT, "Aortic Valve")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d46fa29-1d40-4ed8-8da6-e4c4a45bd751">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1254804a-5665-4f84-a874-608ea158a3ed">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9d52017-8638-4ba3-8e94-6e0f4d120724">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7777c500-770e-4c3c-ad75-3689624f6c1d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83d81948-4d89-42ed-8064-edda26fcdd8f">D<xref linkend="sect_TID_5203" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cca8c3e4-6bcd-4ca6-b156-6d65dff16cc4">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_678d62b2-345e-4261-9a83-1e393c49e932">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9788ed8a-9367-4f42-a113-70aebc3aeb01"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bcfb0bfa-96b5-4fd4-8cb5-4178d8869f75">$Measurement = D<xref linkend="sect_CID_12207" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_a27f83e5-dccc-434e-bc6c-402c0870b4b8">$Method = <xref linkend="sect_CID_12227" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2d77966d-e2f9-4bcb-b576-fb47db1a3a22">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16e1a48d-9b89-4db4-960f-04b8d18bd553">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02df2639-e32f-412f-becf-4d8442851a14">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5611920d-9618-42f3-8569-b006b2307de3">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1340f253-8934-4b9d-85e5-3d2108ad6b69">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7356d11-13a6-4c8a-b6b6-f20bd90ab213">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_705e205e-c01f-4118-8f95-fc96150a2459">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11ed96e6-4a84-4403-8f86-4898bba7f338">IF Row 7 measurement concept is in <xref linkend="sect_CID_12222" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2fb16c2a-75cd-47f4-b8f4-bac0ae552d63">EV <link xl:href="http://snomed.info/id/91134007" xl:show="new">(91134007, SCT, "Mitral Valve")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_167e9be6-32ce-40e2-8e35-e7a596931559">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_95cc3cb9-be5c-496b-837e-e30ac194255b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b902ead-6fed-426a-a4a3-3805028bf507">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5045acdf-fd62-4831-b22b-f275e54f08d9">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_12d5bee8-baa7-49e7-9ba7-2920b5204280">D<xref linkend="sect_TID_5203" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3d52529e-d270-4ecc-8aa9-9bbe1a53a10b">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8a8e3011-1966-4f23-92c9-6658340f0c49">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c74e6dee-8398-412f-bc8b-9b2959c2f622"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a0ba0f9-ba7c-4a28-b7e9-be1e3a2a2f57">$Measurement = D<xref linkend="sect_CID_12208" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_cb52b8f7-4a18-4dad-9d53-211270622025">$Method = <xref linkend="sect_CID_12227" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2bb67b7e-f6b7-4ceb-91b5-30d4316ac90b">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_45b4d2d1-c159-49f5-a40b-618da40d9c9d">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4298319a-65d4-415d-8eef-7ef91e4b8b31">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d893bc66-4708-4fa7-a6bf-838919b0ccc3">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_213612c0-a120-494e-87a9-60638e16f92d">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_62c8412d-f24f-4e40-ba28-e8b67e8ef23a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e4d8231b-f75e-4928-8551-0944be358d07">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_db0036f9-88f9-4b74-bd92-4331b1a3913c">IF Row 9 measurement concept is in <xref linkend="sect_CID_12222" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9eac20c7-1dcd-4867-a002-ce96aab5c244">EV <link xl:href="http://snomed.info/id/46030003" xl:show="new">(46030003, SCT, "Tricuspid Valve")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0d21331-90a4-4272-aab0-bc58416b73da">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe8eb56b-c60f-4bc3-82dd-213ef3f268b3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_958a3eb1-ea33-45cd-ba98-81107e0cb058">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0230cb84-4620-40fb-a161-b178f3174e40">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e552a0e-318c-4f63-a5ac-98660911c1eb">D<xref linkend="sect_TID_5204" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f0bcd206-e583-4c8f-b28f-cf76cbb4bd8e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0399bae5-b1bc-486a-bdad-d2bf46c06599">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_94bfadc3-84ed-45b4-bfd7-4c6e69b6b44c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80e228a6-3ebd-41e4-978d-4507dd269016">$Procedure = DT <link xl:href="http://snomed.info/id/35757004" xl:show="new">(35757004, SCT, "Echocardiography for Determining Ventricular Contraction")</link>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_d16e9759-e8ec-4a88-99c3-9943c2c163b7">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b2c235e-d457-4041-92df-707b54cc9c2a">Rows 3, 4, 5, 6, 7, 8, 9, 10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eee5da6d-c7b0-4391-b77c-721332b9cb0d">These invocations of <xref linkend="sect_TID_5203" xrefstyle="select: labelnumber quotedtitle nopage"/> do not include an inherited Findings Site concept, for example as in the invocations of <xref linkend="sect_TID_5203" xrefstyle="select: labelnumber quotedtitle nopage"/> from <xref linkend="sect_TID_5202" xrefstyle="select: labelnumber quotedtitle nopage"/>. Echo measurements that do not have the associated Finding Site pre-coordinated in the measurement concept (i.e., the orifice flow measurements of <xref linkend="sect_CID_12222" xrefstyle="select: labelnumber quotedtitle nopage"/>), shall have the Finding Site explicitly post-coordinated with a Concept Modifier (Rows 4, 6, 8, and 10).</para>
                                <para xml:id="para_d6d5a765-2a8d-4f3e-8801-670be5713ac0">This Template does not include the concept of an Image Library, for example as used in <xref linkend="sect_TID_5200" xrefstyle="select: labelnumber quotedtitle nopage"/>. Image Content Items in the Echo Measurement Template shall be included with by-value relationships, not with by-reference relationships.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3311" status="3" xml:id="sect_TID_3311">
                <title>Stress Test Summary</title>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_887bbb71-6b92-4641-9ab0-901a30a43b0f">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_d1341159-bc1d-4151-acf5-22e7f8cc862f">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_1de481ab-8122-414e-8100-eea1fd02bc6f">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3311" rules="all" xml:id="table_TID_3311">
                    <caption>Stress Test Summary</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_072e8104-67c3-46c7-b5fb-d31a8ab08620"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b5e38644-ad78-45ac-9dab-e0146bbfffc3">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a66fe46f-ae03-4bc2-9bfd-5dc8ba2f5687">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_71b66c6e-3029-474a-bcff-b6951dbab505">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1d3893b2-5831-40b0-b3de-897efbdabd59">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_60c57d00-1591-4a96-86a0-ed47a4521b8a">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0c83b9d0-0eb4-4e71-8b13-56f7f856c10f">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2cc7d048-d099-4465-a4d8-8f39a0854a60">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e6cad816-cdf4-42b2-89bd-e3063e59832b">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f42420f3-b7fb-4bda-9408-fb37be199897">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e05c533a-7e14-4f17-b68a-a3b549bdb8c7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c274e2b6-c731-49c7-af3e-f083657877a4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e6f2231-184b-46fd-87f3-02291701607f">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_986fad79-afac-4729-bf2e-29bbc9a977f0">EV <link xl:href="http://loinc.org/55112-7/" xl:show="new">(55112-7, LN, "Summary")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_57ed2077-8789-4db0-8444-0f82d073ba2d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_66a6cc85-df0d-4d53-8e90-4addb61859ec">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_66c3e57e-e3b9-44b0-8a10-de446b471d87"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a962886-bde9-4203-82d9-e217eef1dee0"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46457373-70a0-454b-85ba-12a9aa28c647">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f632467-eb11-41c1-91de-00772c1cc7e6">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37162fac-b7a8-472e-8c1b-a546eaa7dd9d">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72d4fcb4-7ef7-4e0b-800f-1af3fd98767d">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3f5b32d-0b13-437b-add6-f30f36b836b4">EV <link xl:href="http://loinc.org/55112-7/" xl:show="new">(55112-7, LN, "Summary")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b03a595e-4d94-4bc8-8488-8af38203a400">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_89e80976-7fbf-4c16-9331-31deb058686a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_639518c3-4d4a-480f-80f3-61d0a003bd8a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d6039ac8-34cb-4ce1-8308-ef271538387c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e21142a7-0ace-46e5-ab27-ac07d6931fd3">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dfc3d8e9-81cd-44be-b9db-5e3a5ecced7a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46987f72-6624-42e0-a612-68b623cbb13a">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99373d47-0795-4e60-ae44-72a168eea0d2">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_89477c48-f52c-44ac-9915-61b3ac6743d4">D<xref linkend="sect_TID_3312" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5bdd5937-00e8-40c7-b440-57dc03b014c8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_15e00bbc-734c-4fe3-9e24-927d6d968845">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0c3c863-7b39-4931-b175-78c7b353a7c5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0dd875c8-31fe-495f-a1b6-b9bd2e4f0a21"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_33f29056-3976-4c4a-aad0-f7359fa5653a">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd1b4f4a-5f11-42f1-968e-c0801645d70e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0a3ef34-1661-4725-ace1-c5c5aad93f0b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c9abf4b-776c-4210-a6fa-0cc83ec2ac0c">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3007303-588b-4fc2-bcb5-4a89e7267bcc">D<xref linkend="sect_TID_3313" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5f19a08f-351f-4dae-bdd3-0b818596477f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_de3f63fd-9afc-4b2d-a8e7-e2846493f7ec">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88f63d9d-7cf3-4d2e-8179-a916bd19b0e8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0bd14a5b-8bcf-4f8d-99eb-faf58551772f"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6473f5de-4903-46a8-8adc-0056b7780279">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_18ad3eaf-72b1-49de-a856-052f9e6ff891">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c44c5b4-eb7f-429a-a11e-5cee27c5eba6">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eae24d0b-6831-434d-9f91-6cfe89b5f7a1">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67bb0a8c-8bd1-45be-95fc-7829d76ec91f">D<xref linkend="sect_TID_3317" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6923a447-7853-4732-9dff-37e1f5aab469">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ede5a4f9-0bcc-42da-86c2-e6e46eb997c7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c433dac6-26fc-4d2b-ab6e-17322c14df9a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fdfe04f4-dd4f-4857-b866-5b86a222ad65"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a61aced7-5871-4e0e-ae82-cd18ee6d72b2">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd1995a3-217e-4f80-8266-e39d3ff52c90">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c92d12cc-7e03-4f8b-b210-b866d26ce986">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3dd0e529-62ad-486f-b66c-2872fbb05a1e">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e497934f-a85d-49dd-88eb-4ed01b5fe7e4">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_98805bd2-2380-46d4-940b-cb8c9b042fe0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aacdac60-c1e4-45a5-9f37-3bff77482f69">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d25ff4a0-1b71-4991-9e16-739c600c5467"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_95cb1d1e-bbe1-498e-a347-c3f7faf40bdf">EV <link xl:href="http://snomed.info/id/300995000" xl:show="new">(300995000, SCT, "Exercise-induced angina")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_720b784c-aeb5-4122-a208-006aa5b077d6">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ffcb66d-777d-457b-9ecc-16fbed1f4ab4">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bfa337f0-647f-4e51-b6ea-49292c8b6fa8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3cb10cc-8097-4816-a3fd-8c7ea0019143">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc5b9724-904e-4480-8d88-ff11012601cd">D<xref linkend="sect_TID_1350" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e2074f9f-7dfe-4e8b-815a-8ed7f780ec46">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_23aba092-2a30-4c10-85cd-9b2e2773a4a8">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be79ef4f-47c4-4ef8-ac74-e9dd89884f4c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1f0d9ce5-8040-4393-b512-182329aa37d9"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce9782dc-0984-4cb0-b382-526682727cd3">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3dc59e8-5942-4fb3-9b44-51e874a0616b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c24b0774-aaa3-4431-bc75-b7a60152a3b7">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8854d85a-8c07-457a-8908-e7f75eaf2b47">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4130781a-c71e-4324-afc1-e752b62953ac">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_81ee4132-dc61-4538-b392-f1d580638181">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b54ef821-03cc-482c-9372-2cd55f370756">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_15e8c2c4-3bce-496b-8353-f52319d107f2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_005cac74-63a3-4f4e-9a75-cc30bf565b01">D<xref linkend="sect_CID_3220" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11724d48-16c1-4b32-8d32-d447ced4a25b">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22997677-bad0-4dc9-a100-373b1dd09a40">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_043421db-944c-40a5-a8de-fae06c026479">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8afadad4-17ef-4381-b0ea-d5b01be01a21">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3542bbe6-4a97-433c-9879-6e55184057af">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f3f5485d-cd9d-4518-92bf-906150ef2056">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_98f11811-ea67-43f9-8595-f4e4cfd2d105">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_791153b5-5bab-445c-a34d-14a5eef9b853"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08c1a942-59cc-40be-b090-24a3c69bdb78"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c901a9ae-7a43-4afa-a230-8b3d953d155a">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d3b0c59-4537-412a-ae55-761229af71c7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e9967ca-e359-49b4-a3bc-47536e1125bf">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7003a7b7-90a8-41a5-937a-532b52539080">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f9b83a8-1f16-417c-a263-eb30d1289d3b">DT <link xl:href="http://snomed.info/id/246101005" xl:show="new">(246101005, SCT, "Reason for stopping test")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d4994ed-66b8-43e4-a882-6f9719381f7c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_858eefaa-7848-475d-b370-d97df394fa5a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29ad3741-f199-4449-acb6-c75d348e3cfe"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43392719-cb97-472c-aba6-a6397c9e72a2">D<xref linkend="sect_CID_3221" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_558c2833-9538-4fea-8e05-f3ec30b82322">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7d9f096-29c2-47c7-831d-edd05766a791">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6124436e-9d9e-4074-b9b0-78626189bbf4">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fcbb54d1-36c0-4b97-8351-cd98d77f7f9c">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2332bd5c-d8c8-4a75-a9bb-31a352ce46c4">DT <link linkend="DCM_122715" xrefstyle="select: nopage">(122715, DCM, "Pharmacological Stress Agent Dose")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_29aaadfe-f251-43e1-aec5-df89de4699e8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b9d68ff1-c20d-4848-ac78-1e141d059ed8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8130588-eebc-4dfe-ba0b-5bf090ce6569"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_affdd0c8-4004-4da5-a22c-d4afc325c298">DT (mg/kg, UCUM, "mg/kg")</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_df9c436e-77de-4760-afdb-2d315d503190">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06f828ef-9083-4acd-929e-abb78e0da0da">Rows 6, 7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ebfa5302-be04-40f6-adbe-1dd686c8379b">These rows allow an explicit finding of presence or absence of exercise-induced angina through the <xref linkend="sect_TID_1350" xrefstyle="select: labelnumber quotedtitle nopage"/> Concept Modifier "Presence of property"</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3312" status="3" xml:id="sect_TID_3312">
                <title>Physiological Summary</title>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4a60be26-6a20-4660-b930-57c170fd7658">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_467205ee-056a-4434-8823-e3d0f6e071ed">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_da3b1e9d-d008-4cce-b49a-2ab99891a089">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3312" rules="all" xml:id="table_TID_3312">
                    <caption>Physiological Summary</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7837bf5d-5d23-4d25-871a-2f52ed69cc36"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_61bcaf9a-e501-4065-811c-65723f2a5da4">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9763a6ec-ad54-4c63-855d-3cb8cd582bdf">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_605dc82b-e31c-42c3-b774-41002c68a390">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_07969631-386a-4c83-bb06-402844efe096">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ea0591d5-84b8-440b-b00b-c41dcc22106b">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_64cea47a-ae5a-4f07-a639-ecf209b7f25a">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6859e225-cc0c-4d36-8404-2c0738f2b4a8">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f92b9a19-1926-4b81-b35b-eb3284407437">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b379cb00-e08a-44c1-ad81-9f0a175b3ed8">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4c46f99-c4d3-4e62-a628-dd54faccb2c3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08f75350-3dd1-4917-972a-6dc69357aaac"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f5bebc7-8cee-4bdf-9aa1-4c98ae9ccd7c">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c997f20-6fc0-4713-925a-ad115c1137a2">DT <link xl:href="http://loinc.org/40443-4/" xl:show="new">(40443-4, LN, "Resting Heart Rate")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_90a4b33e-3eb4-4c7a-8b5e-e76515a56c04">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_188b7334-bfa5-4f18-a494-594c7450088f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06a4df5d-508f-40b5-b7c5-4684e27b1bf9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca40e4b1-b0e7-4a7a-a253-5d2a462bc0b6">UNITS = DT ({H.B.}/min, UCUM, "BPM")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1349dd74-44de-4af6-8ae5-c237f5cf7b89">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aab7ee65-69bf-44e9-ae56-d9bfd45292fc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_730e8680-f2cb-4e77-89ad-f735f7d17b32"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_557d4ead-e0a4-4b41-bdaf-a6b0a10ebe96">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b693700d-a500-4c92-aee3-f6d4978b2749">EV <link xl:href="http://snomed.info/id/271649006" xl:show="new">(271649006, SCT, "Systolic Blood Pressure")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_23a671ab-34dd-4585-a090-6e10075b382b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0d9af449-5521-421b-8296-25901630af0b">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1113c1b-52d5-40a3-b8dc-bb52e5b0bb6e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_814223fd-6999-4e84-8191-e8375d4c8029">UNITS = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a814edd7-d614-4d00-ad24-23cc6dd0a406">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d08f7c5-57fc-4328-8f7b-7fe2758d4b6e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2daedcc2-3925-4a24-b436-af8ab370db88">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5553d806-b4b2-4b0f-acb6-1dec73cf0a46">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1c0fe8b-f8ee-4799-ad28-ae4f0c3c5a35">EV <link linkend="DCM_109054" xrefstyle="select: nopage">(109054, DCM, "Patient State")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_769a414e-dde1-4b6f-8d81-e7af67f6a2f4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a13a4eee-92c3-4eed-889a-04692c4f2c95">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be436b5c-05b7-47e1-b385-e384fc00a51d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29eb195e-c834-4921-b00c-2eb4d7767baf">DT <link xl:href="http://snomed.info/id/128975004" xl:show="new">(128975004, SCT, "Resting State")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dcb3f7b1-6aa3-4507-ab93-7c752e5bc5ac">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd2140ba-c06d-4a03-9d3a-bf5a7b716e04"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fcd3e2c4-17d1-4860-9b67-245c798cdb3c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb60244c-7405-4766-8144-3b4ddb1dce4b">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e0f6b7ed-54e1-4ab8-8a22-126a6fd9e095">EV <link xl:href="http://snomed.info/id/271650006" xl:show="new">(271650006, SCT, "Diastolic Blood Pressure")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bebfe508-907e-4910-9265-017d3962d20f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f2af005-c51d-4540-b89b-40b8ce1abffb">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4c6bba2-91eb-4795-bb1e-d99420535f19"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03f956a6-67b4-4f15-9309-eb2ab2d6adfe">UNITS = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88220b4a-fd5c-4f80-93bd-a97745679912">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b324be3-4619-4f08-a669-51a86b2ec97e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d354e2e8-25d0-4b90-a096-c4ee987c696e">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d0186c1-9c1c-49c2-a34c-c8902581f015">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_618ea926-9ec4-487d-acf2-989b7363712a">EV <link linkend="DCM_109054" xrefstyle="select: nopage">(109054, DCM, "Patient State")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e2b3cbc3-2af7-4625-944e-27507b760e8a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4ec8d905-6680-4fd1-b5e2-90a0ee136f72">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1fa311f-e2cb-4af7-9a3c-cf472f1a476e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d14a3af-3b1f-4a3a-88c2-f4aad0cd22d1">DT <link xl:href="http://snomed.info/id/128975004" xl:show="new">(128975004, SCT, "Resting State")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf95d7fa-c75c-4127-9ada-63e2361b2b4d">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69df0410-6679-49db-a95d-d685c6ef089b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1261e104-9f9f-4c1e-bd1e-79b66e873105"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59921ce5-25ec-4051-9c39-1a185ee254a2">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_68397955-28cf-4b71-a994-87f5934e0a61">DT <link xl:href="http://snomed.info/id/428420003" xl:show="new">(428420003, SCT, "Target HR")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_77aec200-387b-4f47-9e58-d4fdaa021dc1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6cefa26f-30cf-416e-9108-98215cd5bbff">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98db421f-f427-4935-b4a4-7f9cf70ba2ae"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f051def0-0118-4dc7-a72a-38bc18b74204">UNITS = DT ({H.B.}/min, UCUM, "BPM")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_718b5b5a-f9bd-4ef3-b3d7-1244d39fe53e">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_028159cb-1c45-467a-9f10-3f0243032ec2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a90e9f35-c184-4531-84ae-a40149f2a28c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a08046b-2f4b-45f9-901b-161bcacff192">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_208cfd28-4a10-4949-8460-cfcaea3d032a">DT <link xl:href="http://snomed.info/id/428630002" xl:show="new">(428630002, SCT, "Maximum HR Achieved")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_244cd68e-b09a-4a24-8e1b-5d6f1943f584">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_71092656-6ab2-42e7-992b-47d91010efdf">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bfbb5279-205d-4a88-8532-ada77832be8d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6ceab60-26ea-45b6-82a0-c0566dce64b2">UNITS = DT ({H.B.}/min, UCUM, "BPM")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f20aa2a-d2a9-4c05-8e09-c2b9a2f373c7">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_94cce92b-abca-4941-befa-c14b3e02dabd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d4b8e9b-6189-4076-8fac-210b78dc7f96"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f56781d1-9dd3-4105-b6a1-13f4ad04a7a9">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61eb160a-24f3-4bb1-be3b-74f0e50ac09a">DT <link xl:href="http://snomed.info/id/428630002" xl:show="new">(428630002, SCT, "Maximum HR Achieved")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2b03b43e-f5a6-4a4f-b0b8-310f65fc56ca">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc8c915c-1172-4723-91bb-5c3af3d1b5be">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06bb4b87-9c35-4d7f-8a86-5e89a7186984"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75ef1293-3c18-4e28-83d8-4732689f4e42">UNITS = EV (%, UCUM, "%")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba2d5608-c1d2-42b5-94c2-02d1e56897c3">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_56afa106-5469-45a6-b275-b5c79cd50c23">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1dcdd6c8-29c8-408f-b5bd-bf6e17983781">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d04db14-ce25-4ff0-bd74-bb565a73fb25">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae442690-af05-41fa-8f47-65c44de6a75c">EV <link linkend="DCM_121425" xrefstyle="select: nopage">(121425, DCM, "Index")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_01d43585-07ba-450f-beef-7656a363e5fa">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2dcc4acf-1788-4349-bf1d-5a0b07718391">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_647a4e01-9f97-40db-81c3-51465af73e92"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_95d3ef39-25b9-4f35-91f9-297a690ef887">DT <link xl:href="http://snomed.info/id/428420003" xl:show="new">(428420003, SCT, "Target HR")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d01fa1d4-438c-4400-b9af-8fb7731576ed">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_976ecc75-3793-4ea2-b760-ac2ee44c8c8f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3d8cfba-c89f-4fb0-be87-bbe0275e24a4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc12fd6c-7bd5-4000-952f-8dad8319331e">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd4d42ac-2f07-44a4-98e9-604a025bf1cc">DT <link linkend="DCM_122716" xrefstyle="select: nopage">(122716, DCM, "Maximum Power Output Achieved")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e2aa7414-584a-4cf3-ac34-37be5b4186e1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4971d44e-477c-413d-a827-728c1ae5f7d0">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_23a21429-72a0-47e8-aea2-d7843f53a5fc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51787b34-c57c-4c74-9380-9eb406d58a85">UNITS = DT (W, UCUM, "Watts")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d68faf4a-3405-405a-86df-0009578bc080">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d5a9d07-a89b-489e-b0bd-a124992b271a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a504b648-a6de-44fc-8395-14f9b8e56711"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3d061b3-febd-4bff-846c-40fcc7389785">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e5d4b9d-3c0e-4793-83df-600adb72d93f">DT <link linkend="DCM_122717" xrefstyle="select: nopage">(122717, DCM, "Peak activity workload")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b3a0721b-717e-4681-919f-a422c4d0c9cf">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_885cffef-3eb6-49f6-93ea-8aee9c2d867b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3d4a541-ecfc-46f2-b9fb-6d66bfd81a99"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e126e10-0ccf-4955-a87a-07f86173afc3">UNITS = DT ([MET], UCUM, "METS")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09bced3d-a2a8-4789-b440-4ec1ba705234">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6810deda-281f-4a52-9dba-3463569414f0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f7902f8-cc97-4ce8-abea-1cd9f45d83b9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8408b8e-2fdf-4e3f-864b-bbc91b5da88c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13088739-83ce-4b7e-ab5f-65aa07dc58ce">DT <link xl:href="http://snomed.info/id/428531008" xl:show="new">(428531008, SCT, "HR Response")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_93a0d727-8209-4c20-bc73-37e95284a83c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7c5a2f5f-2f24-4f2e-8366-9521b00c1d28">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa2c3d4b-464a-4592-a15a-dadbf663b36a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87826e98-a8dc-408f-a7d2-83930d0421a4">D<xref linkend="sect_CID_3210" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4d7e017-e0f9-44e5-8e6b-0439f0870116">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e9a4454-6b94-4911-bded-618b594ec121"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_db691c81-4bf4-467b-99f4-dbb7f17d4258"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_982721a2-dc43-4237-be88-beba3493737c">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_227fd154-61fe-4f91-b5f0-210ec311822f">DT <link xl:href="http://snomed.info/id/314439003" xl:show="new">(314439003, SCT, "Maximum systolic blood pressure")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_81d2ebc9-3f3b-4b49-b457-b3e856b59036">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_105d1e1b-c25a-4818-b044-16c714428ed7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ee07b16-7049-41fc-8e2c-6d4160c3a051"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_719666fa-0086-43c9-be33-ed984478c3a7">UNITS = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02b91877-0894-4b3f-b033-7b67fce5df57">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69bf05c9-337d-424e-b568-5203f9918da3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e44f380-5c43-462f-8fc4-9c9c6966162f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ab4c90d-a63a-4de4-990a-da3e99c1e836">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_391d0d9f-e73b-4d5a-a971-d4d5faa3f3e1">DT <link xl:href="http://snomed.info/id/314452008" xl:show="new">(314452008, SCT, "Maximum diastolic blood pressure")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aabfb53e-0b96-46d4-b990-1b9dfca48fb9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_82a5ea6a-43c4-4ff0-b5da-1256dfe637d7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67324224-16a5-43d8-be32-59aa736ef901"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4899da1b-2ff9-4243-a0f1-8697bac154c2">UNITS = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_490b4cf9-257b-4c34-ac7e-63850287e344">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a2a303b-014e-4fe1-82f4-e9be748bf037"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10bdcd42-46ff-46da-941a-8438bc33993c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a29cfdf1-d80a-4457-9720-52fbf2899902">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b45c64d0-ac0f-474d-b62c-f8ddab1a86b6">DT <link xl:href="http://snomed.info/id/427732000" xl:show="new">(427732000, SCT, "BP Response")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_01bb0b78-dde3-4ab8-a738-96f43555cb04">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a2a8cd7b-b812-465d-bb68-6ed4ea585b29">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_305241a6-4e14-4a1f-ac1e-68a05257aa99"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ca8b81e-fee8-4fa5-a44d-01c0daa3acb7">D<xref linkend="sect_CID_3210" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62123c3d-42d0-49f4-bff0-2f00d556d52b">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1c72edc-fed7-4b62-9df5-b13d12fb65fb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ddbe7fef-0705-4cb4-9a98-249354be06b8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3af9d6ae-94a8-41aa-b941-e3a625e19744">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a1e63fe-e24e-41b0-a1b8-330d75408f96">DT <link linkend="DCM_122718" xrefstyle="select: nopage">(122718, DCM, "Peak Double Product")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3436134b-04b8-474d-867d-27d266b14bfa">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_616979af-72d9-4895-97c1-1b85c7e95eba">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62ae42f8-3d26-4420-9f43-6a9244869e8b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11576e92-26d9-4593-b2f8-bb269e9e1069">UNITS = DT (mm[Hg].{H.B.}/min, UCUM, "mmHg.BPM")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_876912b1-dd29-466d-9024-0c724a9ee3ed">17</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae486483-ae90-4d18-8297-7cdb3e39f00a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c49d39f8-701e-4baf-8d5f-9c262cab4efc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c55d29cf-7a3c-4401-a9f9-675a4059f24c">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d89dc10a-f7aa-43c2-b284-dbed84777f5e">DT <link xl:href="http://snomed.info/id/252130009" xl:show="new">(252130009, SCT, "Total Exercise duration")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2564e5f5-057e-4b00-8997-533a2568644f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6bb99500-65f6-45df-a3e9-52b0bd8087a1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ceb51c98-56d6-4e3e-bfdc-8ab67b0b49f9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c95f6063-0d62-4274-869d-16ecbe8378cb">UNITS = DT (min, UCUM, "min")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b496110a-23e0-4ac7-b791-5467be51f5f4">18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec30b3b7-8dd2-4d46-b9b3-2d59864a3ab2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ed1537d-5a44-451a-a492-88ce515662e4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_94d0514b-b572-40d2-bd9f-88bf6545a740">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae602f49-b70f-486b-9a95-586bbeeb6203">DT <link xl:href="http://snomed.info/id/252129004" xl:show="new">(252129004, SCT, "Total test duration")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_472df22e-63b3-40bf-bb4f-44a6905f75a3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_471ddb2c-08f0-4355-b52e-90eadaa35e93">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_77de9420-c679-4ebd-ab13-a9d870d7d559"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a1ee4275-a104-4953-b940-9f802048fdba">UNITS = DT (min, UCUM, "min")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d7ac9b0e-a7c9-40d2-a76d-a0b7037eadc8">19</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c9fc24b-a993-43aa-91d2-a80418dc0d90"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb91d85e-a567-4711-a221-8d1d60dff796"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a4bc0ce-ef2d-44e9-bb86-350ddded7971">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2904011a-f529-45a4-90c3-3558a4b3f519">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_50b92271-361e-4a83-bbd9-e992e8d1938d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e11ee3b1-3d6d-4ce0-b937-eae2c557b072">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52dbae71-e597-4b8a-bc0e-bb055d7ee925"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1190dafb-8cb7-49a6-83a5-e4f5e60e7eda">$Measurement = DT <link xl:href="http://snomed.info/id/429160000" xl:show="new">(429160000, SCT, "Functional capacity")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5364cbf3-c490-4c85-887f-1e69dd9fc09b">20</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_904e7962-aee1-40b4-9519-c06937f537f1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c33f892e-4d45-441f-bd6e-b365221b8380"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b91698aa-896b-4984-9f7d-048cc45a89cb">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7e23992-508a-4f85-82ea-f0cd696b4a7b">DT <link xl:href="http://snomed.info/id/429160000" xl:show="new">(429160000, SCT, "Functional capacity")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_83e8c5de-1502-45c2-a4f8-109ab385ee47">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_77ff1259-259e-4784-b635-0d8ddc8154ee">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa381061-783e-4e6e-8954-0eec2726762c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a75451a-939b-4e5b-b100-c7ebf0214ab3"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5799521-e99d-40d1-bab2-0ee52e66fd13">21</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9fa77ebb-c38a-4024-b409-4c18de631c23"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2549596-e444-46d4-a6dc-82f720b06a2f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f37384af-a534-4e8b-bbfa-1a78e662b354">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c23419e-b9c4-4049-9364-2bff81a2d560">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e3c40e49-7bbe-496f-8e31-3344d648ab65">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_698df027-974e-4dae-aebc-5c46b8c351f8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae1d433e-814b-4baa-84e0-bba935b40ef8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58767cbe-4360-4b2e-9d75-889a9bfcea5e">$Measurement = EV <link linkend="DCM_122760" xrefstyle="select: nopage">(122760, DCM, "Stress test score")</link>
                                </para>
                                <para xml:id="para_5290fa2f-686f-477b-8efc-c29ef49dce2d">$Method = B<xref linkend="sect_CID_3238" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_930b1dc2-3e2f-47ae-abf5-cf2f72714ea4">22</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38ca6888-f667-481e-a3d0-ecb8889ae3bf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a39d51b5-5f69-44e5-bd6b-f1a6991a4c47"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a1c260e3-1ed5-4545-823d-c4950965250b">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39f1df72-80a3-46b3-919c-b7fe0ac5bbe8">DT <link xl:href="http://snomed.info/id/429157007" xl:show="new">(429157007, SCT, "Heart rate recovery time")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_884dff89-ac9c-410f-9558-82ef29522708">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5f39d261-947e-4fe3-a8d0-187fd81d377e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac7335a6-520f-43fd-9693-6f0b1d80f417"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9fa2fd24-fe0b-4a56-8bac-caa7da2c15a1">UNITS = DT (s, UCUM, "s")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9cbbf820-eac6-4f64-a826-9b099bb38c80">23</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2eb65de1-1c6c-4937-8f3e-5c621a34f97c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9139f0f1-95da-4bd2-beb0-1652673044db"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29f1d9c6-340f-4200-8343-aebb09a50a73">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3579a30b-d4ef-46c1-abd5-529c64fe6e41">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_36106b93-f19d-4f46-bfc4-d59256cacacc">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1da11a24-43c7-416a-84b0-be5e01990547">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d93f5b2-1ec3-4c92-814d-b096f0c3cf4c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_426dd49f-64f1-427b-9cbb-8237dc0111ef">B<xref linkend="sect_CID_3213" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f12d7abe-4dbc-499e-b38b-75a2e48de22a">24</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3120bcf-d744-42a5-b32f-be0c16d4bb9c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef02c749-a998-4c7b-aeb1-f6efdc74f23d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c262854e-c7e5-4546-8935-7f8798e903a6">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6184289b-a26b-4e66-93af-5756dc2c5f68">EV <link xl:href="http://snomed.info/id/395112001" xl:show="new">(395112001, SCT, "Cardiovascular event risk")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f2ad096-9d0c-4e19-b252-420334b90a2c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_429717d2-549a-45cd-b6ad-c7af78a1f11d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bce9ced0-cdbe-4e6e-8a48-c036021ff63e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7c74e1e-3df6-4ed2-b3f5-d203ab67eea6">B<xref linkend="sect_CID_3118" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_6cb75b39-ea42-4a78-94f9-7d5b20220b88">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ec62f49-80d7-4b38-8eb2-d32f226a1da8">Row 22</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_577afbac-88c9-4b49-ae88-78eb030437af">Numerical scoring of a patient's functional capacity shall include the range of the scoring system in the Measurement Unit (see <xref linkend="sect_7.2.2" xrefstyle="select: label"/>), and may include a coded identifier for the scoring system in the Method concept modifier of <xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3313" status="3" xml:id="sect_TID_3313">
                <title>Stress ECG Summary</title>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_8bc9b2f4-78cd-4ddc-86d2-0c3822c6506d">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4cc2040a-a957-4500-85ae-2ebb02c0adcc">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_1c49876b-1c92-4ff3-84b8-776ab11e7993">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3313" rules="all" xml:id="table_TID_3313">
                    <caption>Stress ECG Summary</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_22dddcef-88de-452f-a73c-947bdcfee0f0"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb3de88d-a892-4363-92ff-c8fc54a8d03d">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_19ddea2f-6d0d-4247-8879-f619a617c276">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_889e98d4-182f-4f53-b35d-77ca0dc14ded">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f2b35f88-227f-498e-8107-8944087c04bd">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4779b1b4-ba66-4685-bc7d-99552bcefecd">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_680af75c-3ca8-4c84-86d8-6af5569078d5">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2bb997f7-0e98-44fa-aa55-42cbf95ee0c9">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f86b9012-42a6-434c-ad6a-22dae608fdde">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9dc73da0-5652-456c-ab5a-371840311943">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d74ad99f-0458-4c4b-883a-761786926c0e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73215894-5500-46e9-a4e3-9592c10f0f51"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5d1ee7f-8c0b-48d4-b0a8-7740c74a9a00">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bea942ea-1c80-489a-bbfc-2e82e670c7a6">EV <link xl:href="http://snomed.info/id/271921002" xl:show="new">(271921002, SCT, "ECG Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_be7eff1e-6c54-4926-a139-877d2ef7d960">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_997e4888-403d-47d4-b1e7-51e2b279f074">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a98ea6d8-6cde-4502-89ab-c7ef17aba09f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cfe03249-016e-45b0-ba5d-46c8cde50b05">Device Generated Test Summary</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_deba3cb1-d131-46f0-84da-9a47a3818dc0">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d7ae77e1-2ddf-4bd6-b1db-8075df9fb8e7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_480765d5-d443-4f68-9fe7-5b49c0b9e98e">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f729269b-0a51-463c-80a8-3d39d9a3931f">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d29a037b-5459-4955-9057-e8753adca010">EV <link linkend="DCM_121005" xrefstyle="select: nopage">(121005, DCM, "Observer Type")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eb626e18-d3dd-402e-89b3-89f7609260e4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2b9d57c9-f42f-4eaf-af66-15e44bd9aeb4">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6db43f5a-931e-4e7a-9cc1-5dc2f0019f36"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_14b6f31e-abf7-4a68-b2a8-0aa071bc6aec">EV <link linkend="DCM_121007" xrefstyle="select: nopage">(121007, DCM, "Device")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ac1bbe3-1226-4ec9-a40f-5b369970307e">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef23957c-62b1-409a-9141-8acb0036c55c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_668f88ad-49a3-4804-a45e-5758c1e19e64">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50c1f5b0-3c87-4d7f-a7a2-f66bb9648641">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6d6bb51-1620-4997-b316-6717ee49e664">D<xref linkend="sect_TID_1004" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e88c0b2a-e69b-49cb-910b-4c4dce128f49">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_718bec14-03cd-48c7-bfb7-c14add1c0479">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e78d107-081a-4f40-8c95-bbf7491db80b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9cefa6ae-fbf7-4bc8-a778-0f3587f9f475"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_752108cd-4967-473d-9929-54e98404efe8">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_95078dfa-6e9c-4b1a-8cd3-ccf9f9250425"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d127087-224b-4ff2-9c2f-2ec55af51241"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3fe3a099-66e9-4c53-bb96-4729d67a63f7">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_295703f6-95da-4351-9970-0f2c0ecb6076">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_231246ed-2118-4652-a7ae-a7e4038c9dc2">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c36a1398-2ed1-4640-8b66-e578ac4ef5bc">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7f5dfcc-9be8-4bb9-aadc-6d14de182607"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad502dea-c6e4-405b-8633-8f417ba4b78a">$Measurement = EV <link xl:href="http://snomed.info/id/164931005" xl:show="new">(164931005, SCT, "ST Elevation")</link>
                                </para>
                                <para xml:id="para_a7859277-d7bf-4c32-b95f-9ecbc652fecc">$Units = DT (mV, UCUM, "mV")</para>
                                <para xml:id="para_58a3d389-51d1-40fd-bc82-e38bead87b69">$Derivation = EV <link xl:href="http://snomed.info/id/56851009" xl:show="new">(56851009, SCT, "Maximum")</link>
                                </para>
                                <para xml:id="para_2d34779e-bf4f-4f04-998d-6ff488e76e33">$TargetSite = D<xref linkend="sect_CID_3001" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96acd5eb-5217-45d9-a48a-aea857936fbc">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f155d070-1d2a-4ef5-be6b-5b28ea14b994"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f05a54c-ce74-4a47-ada9-0ecb38b1b7ff"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_db888bdc-fab5-43ef-bab2-248e008e95f5">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6733b364-b33c-4489-8a5f-6b8cb07c4147">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fbcde91b-d919-454f-ac2d-67d0a438a718">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d638e0d0-e112-4730-b334-7abaa9a95bc7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2122ea45-7040-410c-a819-aab821e60522"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82f5a07f-7232-49f5-a752-adf6dd6e2809">$Measurement = EV <link xl:href="http://snomed.info/id/429622005" xl:show="new">(429622005, SCT, "ST Depression")</link>
                                </para>
                                <para xml:id="para_4035cc14-0a64-44ba-88f1-245398363cb7">$Units = DT (mV, UCUM, "mV")</para>
                                <para xml:id="para_c873e3bd-a649-4516-a664-a0e74b874f4a">$Derivation = EV <link xl:href="http://snomed.info/id/56851009" xl:show="new">(56851009, SCT, "Maximum")</link>
                                </para>
                                <para xml:id="para_4731f010-7367-4178-b9fc-67e09f9e470e">$TargetSite = D<xref linkend="sect_CID_3001" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f18804fd-cd76-4653-bba5-dd0cac9f16d0">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9d92e8f-f316-498e-8665-6874d5da1a69"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b9a0e81-5f65-42d8-93bb-51a0fd811938"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62a44392-9525-4ce9-8e0c-07fa9b90ccf5">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a3c537a-3eec-416c-a668-91dfb8c5dfc4">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_961a403a-0d6c-4fb9-886f-9352e4f84dd1">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e91699b5-d8d4-41fe-9c7a-ddbb21d9a1b4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1251c53-8149-412d-a9b1-14b165e96c88"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_767c83bb-b267-42f1-b2c4-6235c67f933a">$Measurement = EV <link xl:href="http://snomed.info/id/428550008" xl:show="new">(428550008, SCT, "T wave alternans")</link>
                                </para>
                                <para xml:id="para_4be242bc-8c24-4277-8984-232ef3c16f0f">$Units = DT (uV, UCUM, "uV")</para>
                                <para xml:id="para_71d59efa-ca2c-4b62-b5a4-c95aa08592b1">$Derivation = EV <link xl:href="http://snomed.info/id/56851009" xl:show="new">(56851009, SCT, "Maximum")</link>
                                </para>
                                <para xml:id="para_62635036-079b-4b3a-b07c-e893f6b1d1d1">$TargetSite = D<xref linkend="sect_CID_3001" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e904ffbf-f7cd-456f-83b3-3640d94f8c16">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5af95ea1-b5d9-42b8-a360-75895d74ace1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69ed8c3c-17f1-4126-9bc4-5f3fa4f810f9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98cd1131-968a-4d50-b0f6-3ee76df2c942">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_faf8f7f0-18a7-4d1d-9d3f-74d5281a4f52">EV <link xl:href="http://snomed.info/id/365416000" xl:show="new">(365416000, SCT, "ST Segment Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f64f021b-7802-4b35-a417-0b90ce58a623">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f595ad44-4f38-4635-84be-75c712152e37">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50b36313-32c5-4a2c-bf52-f37cc8dc3714"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b52e708c-2f8e-41d9-bf7b-8d3b55dea22f">B<xref linkend="sect_CID_3231" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_184cd783-ab23-4a4d-9f7a-d475a2d0f17e">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc3343b9-f49f-494f-9741-6f1b4e2f5e78">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d20cae56-e20a-43a1-92c0-d06077a3d875">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_78658bf7-20a6-4852-bab3-4665b5960059">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_214ef5c7-1f11-443f-aa38-d729ffd7d8a8">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d0e75d0d-3dbd-458b-9f88-c552a27be6cd">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b3163fd2-d367-4a16-940b-95ac35ce55b6">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_33d25fa5-4eee-4c10-b669-b35314493295"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9428e4c1-d5a8-44cb-92ad-295d08dddc98">B<xref linkend="sect_CID_3232" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4cd0c0f1-1c57-494e-9d90-896e26438ca0">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5218d8ad-00d4-42d0-b00d-63626ea0eb70">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_485fd26a-e721-4c09-83ce-a0a11945a5b9">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4df67f99-20f5-4e55-ae3b-c9612c21b0d1">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93230f67-32c6-4a4b-bd27-1036d919924e">EV <link xl:href="http://snomed.info/id/116676008" xl:show="new">(116676008, SCT, "Associated Morphology")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8b88501b-7522-4f06-906e-aafd54c35410">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fe780717-6e90-4dd6-b091-ff9c9603c673">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10fe8707-78bd-4dc2-89c4-9f8d8cdb0cb9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16b0f98a-842a-43a8-8b60-2fbdf4d3c59c">B<xref linkend="sect_CID_3233" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_995f8a38-f677-4e5e-a8ac-21c891a36c2d">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91f89229-3bb4-4f13-89fa-7fa64585bfc1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c86760ac-1d72-4104-b65f-bc4916a73804"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a45f3f4-5273-4edf-b0a7-8c8f98498950">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e8ce2e2-2c26-4209-958d-3cd473824747">DT <link linkend="DCM_122707" xrefstyle="select: nopage">(122707, DCM, "Number of Ectopic Beats")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_da3976aa-631e-4049-85bf-7ed2fe5cc946">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d0ec19cc-e2a7-40ae-98a1-acc6d3c4ff53">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1f8fb716-1c0b-4e4c-b12d-b4cead0983cf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d387e39-2271-430b-b722-28fd87a3691f">UNITS = EV ({beats}, UCUM, "beats")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be2db4c4-0ac1-4e04-b3ba-b899b732fa87">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3d668b7-2cbc-4fa2-a0fe-985517a2ef03">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e30c083c-4bd7-4504-8a25-acd82d3ffa41">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1748093b-4fb9-42dd-9edf-00c9e419f19e">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f62ec31f-0b5e-417e-8d43-938a490964fc">EV <link xl:href="http://snomed.info/id/116676008" xl:show="new">(116676008, SCT, "Associated Morphology")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_80fde52b-edd3-4109-b901-5e61a9958940">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f693019d-ce6a-41c0-9750-04566c5707ad">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65bdb57e-c9bb-4bd5-b054-d0fd2b4c2f30"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c2a801e-94ac-4c80-9e66-60b3d58e8460">B<xref linkend="sect_CID_3234" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cefdff44-aa16-48de-99cd-ca6b61399177">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1e4283e-9f40-4089-9ac1-0615fd23b669"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c5ceabf-7d86-4f6f-8ca5-5327a68b9496"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a263c1a5-6241-4b6b-b461-9d6da83810d4">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2fef4c04-cd13-41a4-afe3-0ff3aea0a7fb">DT <link xl:href="http://loinc.org/8884-9/" xl:show="new">(8884-9, LN, "Cardiac Rhythm")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bfd8b7ad-f45f-4894-8311-1f32d52d9e59">1-2</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cb64b2a8-2b4a-4daf-b877-243455e8265b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_68e8399d-8bf3-4ecf-96c1-44ddb0030803"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc8fa2cc-3836-4e4f-871e-97b3eddd5aa6">B<xref linkend="sect_CID_3415" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67d2bc6e-f156-4439-bab6-3bf966d9db61">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_938a82e1-71c5-498e-ae01-49fb8159b68e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bbd9ba88-8558-44bf-8098-6f2d3622bb3a">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed4d324d-070b-45de-8ee8-f1ed7a724596">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8fa9b294-5c8b-4298-84f6-1b6dbdb87c43">EV <link linkend="DCM_109054" xrefstyle="select: nopage">(109054, DCM, "Patient State")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e04b7ee0-2c15-4676-80bd-1276861a03e0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8da627b4-71bd-4ba2-9a00-1133e08661e8">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_44848451-e747-438e-a51e-459f4ed9de3c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54ab26fb-c40e-4064-84bf-3d3cc2e21de4">D<xref linkend="sect_CID_3102" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1cec09c-213f-4055-adad-a04790ea2da5">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b8faa8bb-bd17-49be-ae76-0205483deb9f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da1d002a-c8ce-41ef-acfc-ab9fe74ba606"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_14ca8fcb-0b1c-4d2d-b2c6-a810979bea55">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c87f0099-266b-496c-91b4-d059121ac7d0">EV <link xl:href="http://snomed.info/id/271921002" xl:show="new">(271921002, SCT, "ECG Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_50b2608c-6bc3-42e3-a213-927d87e33dd6">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d316b76a-eae3-4f8c-8563-787c6c77db2b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f31870e0-e7b3-43eb-b566-d73f6b0fb8e5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b53a2ca1-3c51-4076-8936-3f67adb78495">B<xref linkend="sect_CID_3230" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc7a6e8c-86e7-4f8f-99e0-92a01dc7951a">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62965e3e-6cdd-442c-a2ef-6752d3a3006e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d3f96fc-eab3-4627-9acd-c09bd7a8c13a">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_affb3750-3e94-481f-b99e-8d1848fd4d8f">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4539f931-25f3-4949-aeeb-f91b9589d352">EV <link linkend="DCM_109054" xrefstyle="select: nopage">(109054, DCM, "Patient State")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6078d9e1-5c38-4d4e-a9ce-372888040d3c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c07e220e-796d-4c65-bea9-907d9b5616f6">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06e75efe-08d2-43bf-912e-0681704cf8d6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c917d5e2-4a61-49b0-9a9e-cc24ac0c8177">B<xref linkend="sect_CID_3262" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_08ab1bf6-ff53-4fb9-a3ee-3e48ebf7f466">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69ab64a8-08d4-49cd-af09-3c7f9832ca7d">Rows 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43676f02-3a4c-4286-a469-d685db48485a">Each observation (measurement or finding) may have a specific Observation DateTime (0040,A032) Content Item Attribute to indicate the time in the procedure at which the observation was made (e.g., time of maximum heart rate, or time of occurrence of an arrhythmia).</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6815fb60-0c04-4ff2-9a11-3ff2d988329e">Rows 12, 13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7fef4dd4-3047-49ff-bedf-fc6a27adc2b6">This Concept and the associated Concept Modifier may be instantiated twice, once for resting state measurements, once for stress.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3317" status="3" xml:id="sect_TID_3317">
                <title>Stress Imaging Summary</title>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_09842b0d-5db9-4162-acaa-2c955eb3796e">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4abfdd16-7fa7-4888-969e-cb637b303625">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_8f6a6352-103c-4cfe-8cb4-492f26031511">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3317" rules="all" xml:id="table_TID_3317">
                    <caption>Stress Imaging Summary</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_477b2ab4-e250-479c-856d-255a807f828b"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_83be7e15-a649-4e8a-85aa-8a930c1484b3">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_be164911-af35-44cf-bc6f-dd0964ca2e7a">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d8c3b41-a887-49b8-8777-d0f8ee9426bf">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dee25dae-b731-441a-b090-173496c33135">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_62614a36-b90c-4c73-b501-d8c433a52cec">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_541e848c-f248-4e7e-bfe4-6dd6c61f1168">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b722f5e2-33ce-4bba-a13b-4709fbb04184">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1d2090aa-e366-4734-8c4b-7f4b83c7c13f">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_300d7e76-d500-491e-8c4a-991c696ca794">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be33e47f-7fd6-4d6d-ab59-d230f8e094c1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_917488f9-9574-46a9-ab06-8b5055d04070"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27bf27b5-0a0e-4142-87e1-bdb44257d7af">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb0baa48-f825-47cb-a85e-c6be7f382727">DT <link linkend="DCM_122739" xrefstyle="select: nopage">(122739, DCM, "Overall study quality")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7f2dc0b0-bd06-4149-b0d1-3fa5b0536026">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_24e7b30c-e3d3-491e-8d57-9f7ea31cd3d3">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b4a592d-7325-48ed-823e-978d8135269e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e50455e-901b-4417-8e29-1e6509460693">B<xref linkend="sect_CID_3114" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c08757d-4bec-4512-b656-84176af1fe90">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b9152a8-ed1f-443e-b56c-c070d7612558"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4cb4e05-2420-4b25-b63d-c8e04668da91"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_47c50e2f-ecbb-4c02-9856-4d13d4dd5c91">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1cab78fb-2be3-42cc-bf8b-d18be0929f11">DT <link linkend="DCM_113010" xrefstyle="select: nopage">(113010, DCM, "Quality Issue")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_521a930d-7779-4435-b9ba-390eca78b1eb">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_62733776-8c2c-47ea-bb92-a91eed8d4f4e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2686ba95-cc4f-4a82-ae1f-d3063e96ae10"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9c39add-00bc-4c56-8ae5-037b1a24b2bb">B<xref linkend="sect_CID_3115" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87b715d0-ef53-4674-8d96-2eaecbadfbfa">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8af4a38-9e6f-4001-b45a-0fd694753d4f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_540e7b3e-48d0-49f9-bbb7-01679fae071e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04f3f3dc-14de-4513-885d-a8843f03c376">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b039c5ab-ed81-4ebd-8106-2f7a95580c5c">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_623cc516-08ab-4127-a0d7-4eadf8fe4fb3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f75a8d71-eee3-48df-8a27-ced01afd49b6">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e9a0acb-254b-4cf4-8f56-afdd1ad9764c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad72bfda-8b93-456e-be85-e770535a8c52">B<xref linkend="sect_CID_3116" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb400b80-8792-4374-968c-44f3e6385de5">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_235797d0-40e7-4aa8-942c-d4a2f8516ef0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b791a890-b49b-4425-b5e8-737b13793793"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af2f9727-b9f0-4805-bfa0-f49546b80fbe">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ebf5e38-3f7b-46ad-8c25-0f694fc06bc4">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_646638f9-d72f-408e-a733-1b3856600282">1-2</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_43924d98-bbaf-48ee-a002-fdd2c3a80b9c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b6939b6-5b1c-4318-92fa-d37b15300837"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd56d715-62ef-4833-a750-73e134989828">$Measurement = DT <link xl:href="http://snomed.info/id/427751006" xl:show="new">(427751006, SCT, "Perfusion defect extent")</link>
                                </para>
                                <para xml:id="para_f75f9882-ecee-4854-ada8-9a370641d6dd">$ModType = EV <link linkend="DCM_109054" xrefstyle="select: nopage">(109054, DCM, "Patient State")</link>
                                </para>
                                <para xml:id="para_07278431-d3f1-4150-99ad-889f1ab13792">$ModValue = D<xref linkend="sect_CID_3102" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_371f5c77-5239-4fd8-ab8e-3aed2d5b1db9">$Units = EV (%, UCUM, "%")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c432dc90-c44c-49e3-b1f7-a6e8f625fe4c">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3eb5ec7-cfb3-4be9-a78e-6e6da2465ea1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4378e79b-05f9-4bc6-9187-402fe2da7ef7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8d22eca-40d6-4d7c-90ad-4828b216b057">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e4aa491-5799-411f-b02d-185e83c58a5c">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cba7f0d1-b74b-491a-bd51-1db2ed65483d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dba0092f-9691-48f5-aaa1-7906a0c753e5">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5c6b3df-0bc7-4aa1-8535-73b733ebb23c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21e6007b-0779-4be3-b480-14a6073a3256">$Measurement = DT <link xl:href="http://snomed.info/id/429162008" xl:show="new">(429162008, SCT, "Stress ischemia extent")</link>
                                </para>
                                <para xml:id="para_8bcffd25-a41a-4a2d-93a1-b8042fae3f96">$Units = EV (%, UCUM, "%")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4401765b-631e-4699-8373-14dd3cec7843">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0bd89197-1903-40f4-92b0-b0038e9e077b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_76aebfea-751d-408e-9a05-f9b8cf77d328"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0df0297f-7a18-41ea-8b08-490e82e69887">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b318065-cc8a-4925-b254-2ff900823008">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cded56b4-62e6-42c4-b385-a5883da06d79">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_70b760e8-102c-47ce-87f5-ad80ba4d0648">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f19a5ece-6cc9-47ee-8ad5-4e1fc84d5b86"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5bedf412-139e-41fb-95a5-9a8e7598f1d5">$Measurement = DT <link linkend="DCM_122762" xrefstyle="select: nopage">(122762, DCM, "Number of diseased vessel territories")</link>
                                </para>
                                <para xml:id="para_a9cdb2df-1efb-4e44-9709-26bbbc590dfd">$Units = EV ({territories}, UCUM, "territories")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_310efccd-ce06-4c64-8d9c-d6dad07c1098">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39bdc220-c52f-4e72-988e-09e5a3ccf420"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16c120a1-f0a2-41ea-b1ea-c74b8f416697"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0f6f7ef-3b8d-41c2-81d5-f637f628c693">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7d51be2-8a39-4520-95c8-37a198cd546d">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c0df9221-bf78-4c37-b869-91debcaa1997">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_77767d25-16b3-41b5-bac0-508ae1a0df49">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48dc414e-88c4-4a5a-be87-03643e59c220"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c2fc0a2-e690-468e-8355-f77fbe352e0a">EV <link xl:href="http://snomed.info/id/53741008" xl:show="new">(53741008, SCT, "Coronary artery disease")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2dfa74e5-bdbc-42fe-a852-957da0b6eb6e">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_34482812-c083-4f7c-bf59-4f3949cbe25d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fbf71586-638c-4c66-9474-ffec16131d45">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6e9841c-43dc-4a74-992f-e8c2aa598117">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7f3431f-be65-495e-9737-4932dedb5ce7">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_061f8d57-e411-45f0-83c7-3ae4db8baf58">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d3ed0b19-16a3-44a6-932f-f17271728d18">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69ac486d-8e8a-4f84-b9a1-b818823f3d64"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc2a4f3e-e66c-4470-8c0b-2e899670f509">B<xref linkend="sect_CID_3016" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_23e5ee96-2aa2-4f51-b06b-c85b62f9b3cc">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b78c5a4-cf2d-4062-a060-f45fcf79fdef"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42910e56-d310-40f0-9b0b-5cdf9d939165"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b9cba5a-a50e-4531-9572-376e4fc793cb">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93469a2b-f2cd-4d96-9ee7-31e752073a58">EV <link xl:href="http://snomed.info/id/251053005" xl:show="new">(251053005, SCT, "Myocardial perfusion")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9ef16dab-382d-47f6-89d4-7af0b45ecf51">1-2</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ffab2b29-98e5-42c9-8080-fc7581b443ef">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce9b6135-eb40-4f60-a88f-d64d7dd02a30"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_979ea71c-359b-46c1-aa0c-bbf124bd66b0">B<xref linkend="sect_CID_3120" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e0ee12f7-e685-4609-9d08-a0b3b9e21fb1">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f29d24e4-1783-4733-a883-099609308dfb">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_626b4261-664b-487f-aa73-8c9ccfbda0a2">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa4d9d6a-692f-4450-88e7-a53253170e12">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74fc42a7-ad27-4f69-be6e-a26a5dbe96d3">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1fc5d1e4-3ece-440c-a960-5f91ca35be80">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cc84ffba-617e-4e46-b130-f467dc133f1b">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d7a91f0-8851-47b6-99ce-2cf9bcc6f79e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9afe6df4-5888-4667-85c6-cd506293c823">B<xref linkend="sect_CID_3463" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67d3ba25-08ad-4064-9205-239478832c5a">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de1317df-2ace-48ea-8844-b6a3508b0c21">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa8fdc39-15aa-4c21-b299-81b1a9478f67">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb2c8255-60cb-4211-986b-bbe6a932465b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_018b4a7a-fe90-42d7-b40a-ee776d7b8642">EV <link xl:href="http://snomed.info/id/116676008" xl:show="new">(116676008, SCT, "Associated Morphology")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c2e957e0-d5bb-451d-85f5-38b7961f71ae">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_64aef22a-4542-4787-a2e6-e470e2f605c7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad1bd27f-0d4d-4cb9-a479-11fc3f0e6311"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_006b6d15-b91c-43f2-92cf-30299416ef9e">B<xref linkend="sect_CID_3121" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aafe4acc-68df-45de-bd75-42c91e62e3ac">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2bb1518f-73dd-4114-bbda-06d794f2fa7e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5edaa577-ea9f-4b79-98ae-746e6b8aa40a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5107acdb-5b29-4300-8a64-16dc09650442">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e677d400-9fe9-445d-8f8f-8e2b186c5615">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2b51d5b0-0d5c-41a7-82e7-f689db953c4e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a74b2eb7-abfe-4e8f-957b-3138911d633c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dcf353a5-fd6c-4ec2-bb67-8820bd540066"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b61c88e6-3e7a-4c90-99c3-3d4c0284862e">DT <link xl:href="http://snomed.info/id/429710001" xl:show="new">(429710001, SCT, "Transient cavitary dilatation")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4dcaa5c-6e5f-446a-8529-ea86978f701b">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df2b215e-01e9-4878-bd97-276704ef5d9a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4875f99-7f30-4b1a-929d-64cdd9782df5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1110655e-aa40-4e07-8b13-44f103d521a5">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39cc8eb3-b210-49ec-91a0-e119a8ac9086">D<xref linkend="sect_TID_1350" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f3f47069-0967-45be-8ee1-161c8d31ac4b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_84f82b60-9a59-4c81-a34e-99283d1c773f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26ac382d-e9c9-44e3-b788-6527e3c33b32"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0987de7-3239-4096-97c0-ae43fefd7dde"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37694b40-d537-4df9-9a85-8effa8894b16">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cbf3a653-a193-46b0-95f9-087f56f40b10"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2119afbd-c7f7-4c83-94b4-1e4e4e166b28"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bdbdf143-d19b-4259-bdef-c52101ebcc4e">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0796226f-edba-4b0e-b449-ca6b82103532">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9499809a-ce4e-4b25-ad53-dc7d8a0423a0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7a8de9ec-af26-4a6c-9faf-0938a342a2ef">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5200d15-e5d1-4d28-82d7-38b2446760da"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9408238c-e99d-49a9-ac1f-439a497d995e">$Measurement = DT <link xl:href="http://snomed.info/id/428832008" xl:show="new">(428832008, SCT, "Transient cavitary dilatation ratio")</link>
                                </para>
                                <para xml:id="para_f29fd32f-c653-4acb-8cba-0650e7ec54c9">$Units = EV ({ratio}, UCUM, "ratio")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_47c6c086-0525-4613-a455-1526a6a7cfd0">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31065828-d91e-4d10-af52-fd1cb70ed40c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_282f5523-adbd-4aeb-be58-817ebd0f2243"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1053667e-5364-493c-8537-6aae8ff4102f">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50b38199-3a54-405c-bf9c-b41941723c23">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6292d2ef-ffc4-422f-b484-f22280162b24">1-2</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ad6353b8-2be7-469f-8cb6-0e0432da3295">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_840b7a83-a854-4655-8afe-e755400bae19"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5fc2ddfa-1109-4946-b9a6-ce061e0dcdf0">$Measurement = EV <link xl:href="http://loinc.org/10230-1/" xl:show="new">(10230-1, LN, "LV Ejection Fraction")</link>
                                </para>
                                <para xml:id="para_c1a1568c-7b30-4c2c-b07d-98d57338b955">$ModType = EV <link linkend="DCM_109054" xrefstyle="select: nopage">(109054, DCM, "Patient State")</link>
                                </para>
                                <para xml:id="para_ee41602c-bc8b-4256-96bc-30d490885ee8">$ModValue = D<xref linkend="sect_CID_3102" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_0a281e6c-e014-42f0-a1f5-f13d5c77b249">$Units = EV (%, UCUM, "%")</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_7e181e38-1b4c-4778-8e35-2da50e6caa4b">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_78d2e0e9-f0b6-4678-ab61-10f8aaad5a00">Row 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e3e3bb3-b328-43fb-ac8b-1002f8c85b3d">This row may be instantiated twice, once for resting state measurements, once for stress.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29686efa-7f14-4ca0-beec-2414199379f0">Row 15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f93a8b60-34e7-40c7-90fc-dba4c4d40c28">The LVEF code specified in this row is defined in LOINC with method "imaging". LVEF measurement by ultrasound may also be encoded elsewhere in the Content Tree (e.g., in <xref linkend="sect_TID_3309" xrefstyle="select: labelnumber quotedtitle nopage"/>) with LOINC code 18043-0, which has method "ultrasound". It is recommended that such findings from the per-phase measurements be summarized here with the generic "LVEF by Imaging" concept code.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3318" status="3" xml:id="sect_TID_3318">
                <title>Comparison to Prior Stress Study</title>
                <para xml:id="para_4b005eb3-8e5c-4844-9b38-b4cf634e442f">This Template describes changes in findings from a prior stress study. Comparison is to only one prior study, even though the generic concept name for the Template uses the plural "studies".</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4cd9789c-e005-457f-9231-61c015a642f6">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_d6a5b773-9985-4712-a681-1529588429fc">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_53458241-6515-4665-b3da-92e32714a05c">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3318" rules="all" xml:id="table_TID_3318">
                    <caption>Comparison to Prior Stress Study</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c45196a0-2c85-47f5-95d2-ab2568a830ce"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fdc7881a-edfd-4161-82c8-4e752315d044">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_653a1d40-7dc7-4b88-8ce8-02fdea16a2e6">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_65984951-a0a1-41e0-b50e-76e309ca5682">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bddc9f6a-0e20-4eb7-a0cd-2f0bf9de56bc">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d682df37-452b-4b67-9b42-9af23517c026">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d1b7b1dc-8c03-4971-b127-184527dfcf62">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3959402a-5750-4580-8429-6e3aae6079fa">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_37f69744-0dd8-471e-9aa8-15a6434fea2b">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2d31d4f-892f-4471-afbc-ccf638e6d5e8">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6239b3d-20bf-4619-b4d9-02b134a52e70"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0727354-33b8-4c29-b09d-7da8a3ca5262"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91bcdf7b-63d4-4869-9958-5541af5b2cb6">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1df1492c-2f9e-46b7-9be2-a9e4c4e316f4">EV <link linkend="DCM_111424" xrefstyle="select: nopage">(111424, DCM, "Comparison to previous studies")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d887a378-9263-490c-bfca-bc7af77bb25a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c2414f92-6a00-43a3-a5ea-8cd9baabbaf1">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce235b07-b5e2-4461-8386-569043e51eeb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02ef5fd9-79fb-454a-a9bc-e89a2038370a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63ac1db8-c0ac-4f03-a372-afd5d664817f">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a4b68a8-8009-4639-84b5-d5bd74df9361">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2258dc54-d503-4d20-89cc-232319323cd1">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16d2c525-db69-4155-9604-811152320686">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_630a70b4-bd04-4be5-8b26-f3225c829195">DT <link linkend="DCM_121058" xrefstyle="select: nopage">(121058, DCM, "Procedure Reported")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7339af06-ed13-4d00-952b-a81282b4a77f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8aca7185-094d-4477-91ba-837af3af9434">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eabe46fd-35cd-45d9-8cd1-927f8b24310f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c3bfeba0-0202-44da-beb1-8585b144718b">B<xref linkend="sect_CID_3200" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6b2e3b6-d892-4866-a4d2-930c3a16c508">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_806b5432-973b-462c-8a9e-8d87e407eb49">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5867e8b7-7ac2-4d50-9271-3d723d917e3a">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1240d37-61c6-45ac-ac20-097d1add4ad8">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6fce747-25f2-459d-bb31-c73f3a17e386">EV <link linkend="DCM_122146" xrefstyle="select: nopage">(122146, DCM, "Procedure DateTime")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2388f426-9128-4c60-b0e4-f506a1b5455e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_55e46409-20c6-430f-bacc-eef3c66e16b6">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be2dd422-c32e-4af2-b4de-11c9d9a24a8e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f7d75e0-9804-46ae-a808-8f4af97ccb8c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00e85ab1-42c4-4bc6-95fb-3ff0b87c1120">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21f20b30-5b6d-4a22-9b2a-439e8775f5f8">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea1fdce2-0599-4bf5-9af2-29ee069b7e17">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_491522a9-3fe6-45c3-9a04-116dbba51cbb">UIDREF</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1847d05-d043-403e-be82-9f361c6bebb9">EV <link linkend="DCM_121018" xrefstyle="select: nopage">(121018, DCM, "Procedure Study Instance UID")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7be3e448-e344-46ce-afe9-96ea55691c82">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e87804e3-49bf-4d2f-b471-f64d5168dc69">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d636cdeb-6d6c-4e9b-a298-afd1aeb68f15"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7561fdc9-5a41-4ba9-a342-402ceeeb8759"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3dd400e8-4b4c-4546-90f1-2de4cbf7d5c7">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86636021-0bee-4570-9f51-3c4e9899ac7d">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c8f8a68-a05b-436f-a639-1e4e6e906f6c">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe19cbd8-5495-417c-a2cb-afcddb99d689">COMPOSITE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d412d183-ce5a-46ed-b6f4-5a15a642507b">EV <link linkend="DCM_122075" xrefstyle="select: nopage">(122075, DCM, "Prior report for current patient")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f10f8c82-6565-41f0-a297-4cf7302c1209">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e87278cf-13ea-40fb-afee-62a09ef64567">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4d7fa04-043e-4e3f-aaf6-5ae1d7ed7c95"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7a973010-d622-4dbc-adca-02275fe91be6"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_287aeb16-93e1-4522-9672-9f736defae8f">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a97c94fa-1539-4552-807f-940bf6f04e44">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d09e8ac6-1c5f-4450-8896-af1a49e25180">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c67d117-e8a9-44ad-ac82-a78305d984f8">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5d51c35-7e41-40c6-8048-f6266318ea20">DT <link xl:href="http://snomed.info/id/248243004" xl:show="new">(248243004, SCT, "Exercise tolerance")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0e5169eb-bc90-40e9-a042-8135b7b7e453">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3022337a-14de-4f46-a91c-149f87573f6f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5502a1c1-dddb-4e4e-aa1f-bb998497cd02"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_64ba3102-de8c-4729-b614-31c861dba5fa">B<xref linkend="sect_CID_3236" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_261fe70d-f4e0-45c5-ba94-91695b93543f">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de98ec7e-bb39-482d-b9fb-c142703badd1">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88f55794-2219-44ca-9b86-352329a50119">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_77f504f3-d111-4e40-9fe3-772934855bd6">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f3ef87a-75f5-4a83-850e-45efc9110842">DT <link xl:href="http://snomed.info/id/251053005" xl:show="new">(251053005, SCT, "Myocardial Perfusion")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b99485df-4810-4055-aeb0-f8160741c8cf">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_97e353de-8324-4727-ab81-19bacb8c68df">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b59369be-ce9b-4214-b279-5f5c2aae1beb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24e2c3d9-2832-4b31-8bc5-3076cddae04e">B<xref linkend="sect_CID_3235" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ce3b751-3e57-4917-a94a-89500e1a12c9">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_28469922-44f3-49e6-bff4-0458decfbeb3">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f66500c9-b96e-4265-94e4-c07b3be93f3d">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e68950c-6203-4ad4-816e-c8dd14bd5aec">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_15d0d951-cc87-42de-bb54-ec5b1d0d928a">EV <link xl:href="http://snomed.info/id/370129005" xl:show="new">(370129005, SCT, "Measurement Method")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cd1155e0-2971-40a4-ad86-1bf6fb9cf52e">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_151e8916-9e59-4c57-b0e1-ebf0040aae27">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6ef2139-04a5-4fe3-9d7f-ee1a1ddaf2d9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e1c3ceb4-129a-450a-ac31-bbf7f5b8e6e1">B<xref linkend="sect_CID_3215" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d32a5e4-4869-4466-994f-1238dbc15c75">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a30cc26-2485-473d-aa92-e17b0afdbf50">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5e998ee-dd21-4562-986f-7ebd50f75dfd">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd1b55f5-5f23-40b8-ad7f-fb0e2af95f1d">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_997046d1-e3f5-4097-98e5-62f57776e817">DT <link xl:href="http://snomed.info/id/250909007" xl:show="new">(250909007, SCT, "LV Wall motion")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c7bcf1ed-58f0-440b-9980-2cbba0dc804b">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1d53c22b-77f9-4f91-98e4-62a2c50a020c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_506666f5-74b4-42cc-9fcb-3f70429394d5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08651177-19c6-4f12-b3f1-6c99c9f4d839">B<xref linkend="sect_CID_3237" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e908d01-8479-4abd-82b0-d3e70c9f6527">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31b9f6b0-3a1d-49b5-8178-586c7bcbc80b">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_030ff4c5-c469-481a-966d-5ba8f6d04cf8">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a5e8bc5-975b-4a8a-b628-88128d230bdc">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f9f57f6-abb2-4074-a5c7-2151837c018c">EV <link linkend="DCM_109054" xrefstyle="select: nopage">(109054, DCM, "Patient State")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c037240a-8df6-4247-9207-4f0caa08dc0d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1f0a2ace-d0dd-47a7-9d7b-5471995b6bb8">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6bca9d58-17e5-4caf-889e-242d2dec51e7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1e88e96-f2d5-48ff-a741-feebd3fe1c85">D<xref linkend="sect_CID_3102" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d096589d-57c9-4de2-9f64-8fcb7c040a38">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0ed8954-d119-4f60-93d9-51dff00c0dc5">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7b9f361-726c-48ab-9d01-656fdfd0da39">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1d7c0da-8d86-4e21-a5ee-705608a18d90">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ce2d716-a642-4d79-b0be-4a738abb998f">EV <link linkend="DCM_111424" xrefstyle="select: nopage">(111424, DCM, "Comparison to previous studies")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_44a09e90-a8f1-4ebf-bb7d-d80919ee5997">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ea21d16b-bfd0-4093-a5e5-4f4b9b37c13b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_edcd17a1-e145-4cf0-a370-4f9f236d45fc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7310023d-93bc-47c0-8465-b96468cf5142">B<xref linkend="sect_CID_3217" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31c2ab63-4209-4b64-b9e2-fc9e1564ab42">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7e3b803-25ef-4305-995d-ae7205ad17a4">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e1a5d2cc-0239-4c0e-b5bf-c511948411a6">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0119b56d-971d-41bd-9026-b1c03d49a46c">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4dab416-c009-4e3b-92fe-5a686cf5e679">DT <link linkend="DCM_122768" xrefstyle="select: nopage">(122768, DCM, "Difference in Ejection Fraction")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cc576b2f-9a48-4edd-a6cf-e108dde1519d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_51979cb3-aa40-4b1c-bf92-c9c12d2f590a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b30fd14-7cee-4325-bf96-568055fa31c1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5b2dfc2-02f1-4d59-9802-0d6b82854a27">UNITS = EV (%, UCUM, "%")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c17dd88c-8c42-4672-a291-96ebd8991be5">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0dcdcdd2-70fb-4d17-b242-780a17b71927">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7bacf18-643b-4880-9cfa-dc8462f538de">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_406c73bc-71f1-416f-b628-7a5b8a5fbf85">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c2ea258-2be1-4059-84f1-6b1b19c5a80b">DT <link linkend="DCM_122769" xrefstyle="select: nopage">(122769, DCM, "Difference in ED LV Volume")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_37dae7f2-3129-42ce-be82-41e2082696e3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ff7ed033-bc49-4d80-a392-a7570c8ee4bd">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9830a171-f12e-422e-bb5c-2d2c7460da37"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff50478c-2959-45c4-8473-0de020eccb4f">UNITS = EV (ml, UCUM, "ml")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62bcd452-bd21-438b-b49b-ff433edc67ee">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_550b9a80-eac5-4227-862d-efc0f9a2cf20">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ece4083-5fa6-4c66-b695-952e7f720112">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9aa43289-5896-4658-902b-5a992a36e040">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a36bdb24-1c0e-42d6-b0b5-ba8505b275fe">DT <link linkend="DCM_122769" xrefstyle="select: nopage">(122769, DCM, "Difference in ED LV Volume")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_720e7adc-e593-4714-8b0c-cfb8d8cbf100">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8e34cd4c-04ec-42d7-8eb2-f2545a4c39c7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c946f590-f8df-437f-9833-5e57ca271b61"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81d564cc-bec1-4be4-9007-838c51e3b9cf">UNITS = EV (ml/m2, UCUM, "ml/m2")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_272305f7-da47-40b7-b23f-09fe63d08a73">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_739d2849-3177-471a-b39a-2b65bd55978f">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c197f93c-30a2-415d-8a4a-2fefc31e4505">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2277d53d-d8f6-466a-af28-ed3b9d90aae6">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4babc437-36e7-4edd-9f5f-55e8ed1f3f30">EV <link linkend="DCM_121425" xrefstyle="select: nopage">(121425, DCM, "Index")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_439644d2-1275-47c5-9c95-dfecefa1d7e6">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_464accc8-4aa6-4ed6-8756-6ee795863b9a">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be706464-48d8-4334-8929-de17d222a196"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8886a4b0-baee-412f-95ec-f844cfd2c3b5">DT <link xl:href="http://loinc.org/8277-6/" xl:show="new">(8277-6, LN, "BSA")</link>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3320" status="3" xml:id="sect_TID_3320">
                <title>Conclusions and Recommendations</title>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ca78fc6c-c2ea-41d5-9f26-0fd49e01faa4">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_10d50799-4f70-4672-a1e2-7784805c61e2">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_974153d0-35ac-4fec-a998-830cbd381dc4">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3320" rules="all" xml:id="table_TID_3320">
                    <caption>Conclusions and Recommendations</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_93bd46a5-dcd8-45bb-92ee-3e2bb6827377"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9f0299d0-d637-450b-8628-c5b66a1d417b">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d831f55f-9073-46cb-85a6-f04c6253bb4b">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_df883462-062c-450f-bc23-6d4cb45047c9">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b9029c32-5b5f-4bf0-9130-189859900b04">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f7ed9c44-840f-4230-b213-e3947b4e0332">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_03437138-6f8a-4fb4-a380-ea46bb12a8cb">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_07a82ae7-53a2-4aea-8405-2b27b1ab4ae7">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aa952ef0-b419-4caf-ad5e-3d77cdfe8d02">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8be3cfe-ec90-42e6-9028-5ff9bb5aafb7">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_db451b29-1279-4b29-8ae2-07cc481310c9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c0c3748-73cf-4795-97c8-6962ffd5eb27"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a66100c-e978-4f12-8038-c669de3d1b3e">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dfd7913a-57ce-4620-b018-e21a0f0ad34b">EV <link xl:href="http://loinc.org/55110-1/" xl:show="new">(55110-1, LN, "Conclusions")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_90640d3e-0602-426d-8f92-27ac0684d42d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85befb9d-e65e-42ce-a88b-a9133479b553">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b7b5afb-ecd8-43b6-a269-51572818880d">IF Completion Flag (0040,A491) = COMPLETE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb456b4f-999d-48e2-a899-cc45269aea72"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_32102530-7284-446c-95a0-67e71d7c6c3f">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a93afd9c-a968-47cd-8df6-a36af037e672">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13a9e202-1ced-430d-87ab-82bdcf6d9e17">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd9d7fef-d490-4904-be8d-4bbc2a42f79c">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9125ad79-c394-4ecd-abaa-c3c30f788d25">EV <link linkend="DCM_121077" xrefstyle="select: nopage">(121077, DCM, "Conclusion")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e4a6e8f2-e43a-4eae-aed1-44cc1b15b722">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b07f7300-1b14-470e-92da-a71403f97323">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e039ae3-8091-43e2-bcd3-00cbf571abe0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd438ba4-68cd-49c1-afdb-399b3a7d0353"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc10f64a-4e52-4f81-9602-54b67e627b4b">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_144f1433-bab2-451d-8a74-697a75e2fa78">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6fea730-4e32-41ce-bd88-b7440dcd1cac">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1447be1a-9bd0-4f00-aa01-3524b96effa2">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb1518c8-0615-40d1-a905-eac74098b2bf">EV <link xl:href="http://snomed.info/id/271921002" xl:show="new">(271921002, SCT, "ECG Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_08d8c75d-27c8-4570-9755-9f87fa8dd73e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6a401e8b-4afc-430a-aaa9-0826df238ce7">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc622281-fe51-43bd-bccd-ed1b1557d910"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b81f29df-8a2a-467e-98d4-465fb8399a44">D<xref linkend="sect_CID_3208" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e351557-61cc-42bf-a362-2e0cc491646c">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b73ebe2a-2d34-4172-8075-7c191978ca28">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4191055-6146-4239-bf8e-ac7edf1b69d9">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d7d05a42-b066-421b-b62b-4f4ee679eefe">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5b91153-914d-4a48-b914-2e073fe4a8a2">EV <link xl:href="http://snomed.info/id/365853002" xl:show="new">(365853002, SCT, "Imaging Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_40b18719-e0d1-418a-aead-4433781069b3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7a89fa8-3a66-42db-af8e-4a3a3bb5ac41">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bab371da-bb2f-4a75-b942-34d4c295a9fd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5fe3f3d-98fc-4f86-8e9e-caef129e1443">D<xref linkend="sect_CID_3209" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4906b95-083a-4158-b0cb-15ae3c34717c">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c9c6974-a40b-4d8a-8bd5-119bc3c772cd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ab0c1b8-7667-4fdc-ba02-e35442fdc108"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0bfabbf7-1aa5-4330-a948-790cc816c66c">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4864ff49-43e3-470b-a182-d95539ecc4c7">EV <link linkend="DCM_121074" xrefstyle="select: nopage">(121074, DCM, "Recommendations")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f3075a39-1179-48eb-8a47-5640c7ec5faf">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d4af2de-c76d-425c-87ee-e57dc8fe8617">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6cc9c3dc-da9a-4d8e-a6d1-ee72e4ba99c4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_090b701f-b380-49b3-b9e0-69d7fdff535c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f9d2ef5-1d09-4afb-9651-8b03835225e1">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4cb625b9-f210-4a61-8703-358d77ea4a10">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_029649f8-97db-487b-ae17-5053c28849ea">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a78181a-ad11-4517-a1cd-f8e8e90f22a8">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0fe0e828-42d8-4881-afae-b3b8ed7cf45d">EV <link linkend="DCM_121075" xrefstyle="select: nopage">(121075, DCM, "Recommendation")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_62b172aa-9ad2-46db-aada-3fb2b66adf96">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5f36f695-a1de-4709-b719-b8422ab23028">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_faf93767-37a5-40f6-b5b6-acfd672992df"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6fe8c251-afb2-4705-a012-2bffc8c32b0a"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
        </section>
        <section label="Hemodynamics Report Templates" status="2" xml:id="sect_HemodynamicsReportTemplates">
            <title/>
            <para xml:id="para_0d329eb0-2b7a-41c4-8b37-20ae248c6a97">The Templates that comprise the Hemodynamic Report are interconnected as shown in <xref linkend="figure_A-6" xrefstyle="select: label nopage"/>.</para>
            <para xml:id="para_52d6b5fb-b610-4e50-9c12-37cf64a59de1">
                <figure label="A-6" pgwide="1" xml:id="figure_A-6">
                    <title>Hemodynamic Report Template Hierarchy</title>
                    <mediaobject>
                        <imageobject>
                            <imagedata fileref="figures/PS3.16_A-6.svg"/>
                        </imageobject>
                    </mediaobject>
                </figure>
            </para>
            <para xml:id="para_be39b2f0-0dc0-4230-b977-9b5b29a94172">
                <xref linkend="figure_A-6" xrefstyle="select: label nopage"/> shows only the use of Templates specific to the Hemodynamic Report; it does not show common structural Templates such as <xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>.</para>
            <note>
                <para xml:id="para_d1250bdf-a563-4d70-a570-ca14b1e6f33e">
                    <xref linkend="figure_A-6" xrefstyle="select: label nopage"/> shows the relationship of Templates; it does not show the structural hierarchy of Content Items in the IOD. See <olink targetdoc="PS3.17" targetptr="figure_L-1" xrefstyle="select: docname label quotedtitle"/>.</para>
            </note>
            <section label="TID 3500" status="3" xml:id="sect_TID_3500">
                <title>Hemodynamics Report</title>
                <para xml:id="para_1884c858-1a2c-433b-ad9a-8a41e8129498">The Hemodynamic Report Template is the root structure for the representation of measurements acquired during a procedure in a cardiac catheterization lab.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_9a0e4b67-69ff-435d-b7ca-7a859ac0c69b">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_c42f2927-8996-46c4-a7dd-a87710b3b57a">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_55f481cd-cd12-4f12-b6e8-ecf5383bcd24">
                                <emphasis role="bold">Yes</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3500" rules="all" xml:id="table_TID_3500">
                    <caption>Hemodynamics Report</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1d8b412a-4ec4-45e1-9127-f3c93319a332"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d2a3b32f-11c0-43dc-8327-db7d7dc99b7a">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2ffdb174-42c8-4212-a99d-e86ed8b9c46d">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d2f6fff1-f173-4436-a868-9137601a32d1">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_81441177-4e95-4465-9854-5e8532d2f43a">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ed5c57b-bfc8-4de6-8e29-c8f0cec26dd3">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_61de1733-2aff-427c-84db-01a7f8ff5502">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e17abebc-0bdb-4de2-8ab9-20fce1f8257d">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f8d118a5-0637-4de0-9bf0-51e0f2a2abcf">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4dd7df2f-fe83-47f7-ac05-4e432f6c7b50">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52968b5b-be6e-43bb-a915-a55f367cfb05"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_738424c0-7348-49ce-918c-750dd417fd3d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0784e2f-c634-4817-8bd8-551f738980a1">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9067fb71-7038-4294-b955-14f3f502f523">EV <link linkend="DCM_122120" xrefstyle="select: nopage">(122120, DCM, "Hemodynamics Report")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8cb565ac-bd88-437b-b899-30a2b36cb28c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5c1e5032-1acb-4ca1-8b32-43898ae680c7">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3783a88f-710d-4a76-9f84-3ab855e4882f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80fa2715-8e56-474f-9c4a-42a3479c6aa9"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a51803c0-22d0-49fa-bd22-a570fdb4cf43">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99b3a40f-fea9-4e37-b9dd-34fb9ba97463">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cee6cc17-fc25-4ddb-830a-68f62b92a34f">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f10c0f3-0a80-4e1f-a123-add4a3ac9ac3">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f5b8cc9-781d-47ad-8e41-88aad20e89bd">D<xref linkend="sect_TID_1002" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b4175098-8ccd-416d-a057-4a991ba08287">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_553bf90e-a5bf-4953-930c-8ba2a9f3d6f8">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dda3d889-1b3d-4d4d-9538-713f0cc0d317"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0e3e0b2-503a-4619-b47e-08378afdbec6"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3822523f-6410-46d0-b6ea-6e37b7547e37">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_065a0f33-6c04-45d0-9d5f-d1c69074d4de">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00ea3b56-22ba-4661-9d41-59d13dfc4324"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1f6affd9-d157-4ece-8fe8-8392273e6d56">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27e2ccef-aa38-45a5-95fd-0b141bb8348c">D<xref linkend="sect_TID_3601" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d0efe4ec-fbbd-4d93-99b1-c240a18036b4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ed9140e3-8ce7-4c5d-919d-342379749963">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_01a951cf-a5f9-477a-9c06-9ae341e8d024"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b64b96f3-eef9-48a9-8f18-6dab23a844b5"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ccf7ee08-93bb-4072-ad2b-f5cd3dc35eb7">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e87f826-1d18-4ed4-af86-4e3a00b0d8f3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_723d3e19-8f57-48d9-a46f-8f2b810ab142">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42a9be5b-6ad1-4750-809e-2fef0977f800">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_47992534-1136-435d-bab4-ed41de8b85fc">D<xref linkend="sect_TID_3602" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_33f6e17e-dc24-4c32-a707-64ee85f8e9ea">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ab0c9be-5938-484d-a70e-fdf4f61588ff">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_abf0206a-bd51-471c-afae-a4616f4cfe02"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_383733e7-f2ac-47ce-9d45-c7e8411fddbb"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d522dd7c-165e-47cf-a9a4-f96d28ba0dea">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_425a18c5-6c1f-472d-86a2-0fd4ede8309d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_983a8fb8-ec44-4f72-b5bf-0b5b3b0595af">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d50d3c7b-229b-46c2-bbd5-bd0b21a1040b">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50fd1069-68c6-4e50-be72-bfc798d2a688">D<xref linkend="sect_TID_3603" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e91e68dc-f9d1-425e-a299-ac0156f61cee">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7f5b3555-3bc2-427f-b181-c1a29df14115">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92719d6c-82ca-466b-bd7a-97e9aa5fb849"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc455a4c-ceed-4838-b735-75261212e180"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8efc2827-1e85-4c93-ae68-85b4c02c515a">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a29d220-1878-4c23-a66f-0429ec9b5eca">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ae98a5c-86db-4c9d-a048-8ed8aeaa31d7">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b79fe08a-aae2-4631-99b9-13e2812766ed">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1765c01b-f8b2-443d-9219-7480abdd91a3">D<xref linkend="sect_TID_3501" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9a1faf38-9710-41f4-aeed-8cf51d3abef2">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3c4f448d-77a3-489a-a32b-631e90dcb1a9">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a53eddfa-493b-4406-88cb-7465b539e53e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d0478c6-e34c-46eb-9f9a-c44b5d10bad3"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_896324b3-f04a-45ab-9a89-23a0aaef62fb">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7482e6e7-bf00-4389-a469-56e1116bb463">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e81c05eb-43d4-4170-ac2a-973274a5065e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_849166bf-61c8-44b7-b80e-12c2e20afb43">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca7b5411-f023-4de4-94cf-2ec471450754">D<xref linkend="sect_TID_3570" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2aeab434-946f-4323-ae7c-96e97702d450">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_63f097ca-b16b-408e-83ca-80860fb89622">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5759d0f-3f78-452b-9b66-0e533ac1e01b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00d3e16c-7d6f-4a6e-9673-f62e02b874d9"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3501" status="3" xml:id="sect_TID_3501">
                <title>Hemodynamics Measurement Group</title>
                <para xml:id="para_cb362978-8b45-4d63-8e8a-a6d56f4ecef3">The Hemodynamic Measurement Group Template provides a structure for measurements acquired during a single procedure phase in a cardiac catheterization lab.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_b304a869-0e26-4bee-9ff5-50cb9e9e29cb">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_91596ab8-56e3-4f00-8646-270f6e9c871f">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_b8aa4443-c02d-4d9a-b2b5-39921183fedd">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3501" rules="all" xml:id="table_TID_3501">
                    <caption>Hemodynamics Measurement Group</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2cd36034-d336-484c-bc14-56ef01e12f78"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_126e9665-2331-4cba-b710-4a6609490df4">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fc2b9478-3aec-40bc-84d5-b5308633b0aa">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_29ff3d9c-5e21-4cca-acd0-d05e982a727e">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4dfeafc6-321b-4f22-819d-8faa0225ad3f">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_67a94e2e-e446-4ac5-a8df-aef8bd577f0c">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1e2bcbcd-d710-44fc-b731-7b9570759e99">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a8b1fc7a-257c-4720-b648-e327ebda4c40">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7593f823-f909-49c5-a1f7-424b38fa987f">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c89f83a-d5f8-45f9-b45e-c95b718525c5">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b424d07-11f3-464a-ad2f-0c10a7db9359"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8fda3998-7568-4d23-909d-b017f4f03629"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d71502b-6c62-4873-a7df-a55567026a04">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb42f162-66c5-47d0-9de6-c4c246d1653e">EV <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_02e44f6b-c153-44ee-9a72-79404c250d8a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7f88c188-94a6-43b2-b6fa-51ba4b8e941c">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d2d9a36-e394-4bdb-8379-61ba303b9230"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a171c7d-3634-4ac7-85e6-c824bc414992"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3feafda9-43da-40ab-a569-9541ee433949">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ae5cc24-ecdb-478b-ae95-b6ef2111d27f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f7167ced-6aef-46e2-9352-57674d386265">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6766ba14-8782-465a-96c8-84d8bf7f7c3e">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef720f19-ec65-4c87-8ff5-0a080048e9df">EV <link xl:href="http://snomed.info/id/129085009" xl:show="new">(129085009, SCT, "Catheterization Procedure Phase")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7267d89-755a-433c-9fe6-7e8d8d537403">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c7429976-1427-47f5-9cae-3fb90934ef60">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61d0f99e-7daa-4749-b9bf-deeff0b3f464"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3943cb0e-cff8-4c6c-854d-a3010232bdf4">D<xref linkend="sect_CID_3651" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35c5de7c-81f0-4151-9f23-836f3236fbef">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c98a800-1f35-4f49-83b4-33faa461a606">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_007b84ab-4853-4146-8411-a347e97d4a0e">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17515b51-db91-43dc-b353-0c75a3da7478">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c3391f75-da25-4b9d-b560-5c4f3fe4ce11">D<xref linkend="sect_TID_3520" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b3e45e91-34a4-4e14-9f95-613e09ca45cc">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c40e1985-1b1c-4fa6-bf79-660bfa19f29a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d96f9b55-4a13-425e-834e-3e75500b9db2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f1e5801-1660-4602-b28d-eee8a084cbe7"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_19381af2-73e3-4298-8fea-3f792982d246">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_abc0ca23-cab0-46c6-9e36-d4cbec961ba1">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f50dbdc4-da8d-4f2f-82fb-18dbccece741">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2eaf283b-cbb8-4adc-a3e7-b90ff319ef22">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d4ea7e5-43af-43a4-802a-8482cbd9b7cb">EV <link linkend="DCM_121124" xrefstyle="select: nopage">(121124, DCM, "Procedure Action ID")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_02adb4c5-6b7c-46e5-9e90-5e6b8d2ad7b5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_398a2d24-a1af-47dc-bb47-001ab6a79cfe">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00c832fe-31c0-433a-96b5-6949b95c50fa"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4401c5d-369f-4220-a2b9-abd3abca2747"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_195a02b6-c52c-4101-b69a-d092f74b3201">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_71bd9c42-6e88-415f-89ec-1b20bb1504a5">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_634b3271-e028-479e-bfb3-090de20ea09f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ccf564e-7d76-4aa5-a5cf-1b25376c46ea">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8b449f6-8266-480a-a0db-cae8d1b93570">D<xref linkend="sect_TID_3510" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_deddb235-5e42-490a-a787-085e15446ee8">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e5d6780b-bdc1-4a4f-8dbf-2d59f9981949">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a351a5dc-94d7-4fad-bda0-c0659281fe4e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74dc28bd-94b0-4e47-a49f-720a2a8a053b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_805640d3-2e54-4016-837a-8a64dc89536e">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b234b290-0fd9-4fa3-924b-61da0461a8ac">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5867e0ab-e045-4b79-8733-34fe563ac910">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_19591829-a18f-4ccc-b909-44defc86fc36">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f4faa05-8b88-4a91-9ac8-9308ac4751a1">D<xref linkend="sect_TID_3504" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dda3f6f5-944f-4192-ba6c-deb5825e6a78">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f97d0bc1-379e-426e-a28a-8d32c93d5fdc">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ee43e4c-a0ef-42eb-bacb-09d2349af67b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2448fd8a-7f79-439d-91d9-c8721b2a9b2c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_33e804b6-97d7-4ed5-88cc-83c67dd0735f">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_faabc83e-80c1-4493-b7aa-d005bfd24acc">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae57d763-1a49-4154-a32b-80541475f371">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e4de7e0-e7fe-4f63-9221-2d62535571cd">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e2bdf3b-2aeb-4ac0-8e49-36c234819bc8">D<xref linkend="sect_TID_3505" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7b65b8e9-67dc-4d06-9dc0-e829d16aa95a">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2ec34b85-6473-43c9-983c-85a1ed157f9e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3fb90732-d52f-4c4c-b1e4-f313bd059aeb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48bcd19c-0d8d-4aea-a364-ba8c20b0d468"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3d45baa-bd48-4a75-bad1-8f6e2c33dc84">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cabbd5d6-c8ae-48a4-9d34-a6c9c955caf3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83c05691-15b1-4c87-be5d-f10d9ce9edc3">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4bf17906-badc-4db3-8582-8daba4c01d42">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f7405cc-01c0-405c-bfa8-3c0bf755251a">D<xref linkend="sect_TID_3506" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_922a8b5a-124a-4472-a35d-e2765b0c6750">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6144b9b7-2aea-4440-9b2c-9d3ca3692a4a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f364a351-dd26-4776-b9b8-7ecbd9cdeff7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_898c3eda-12f6-46ae-9680-fc346cefa77a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9af63caa-95df-4c6d-ac3e-9705d1a934f6">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae5d4aa2-8ff2-4297-8fdd-c00674f243ff">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_669b26fc-03f0-4612-9b30-2a96b229065e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf11fb16-5b02-43a1-aee0-75cef08f895b">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5aed5a5f-c318-4b8e-8757-59b07187d024">D<xref linkend="sect_TID_3507" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_14121cec-fd21-40e5-882e-7417616af01d">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6453d168-171b-48c6-bc84-1a726e5efd61">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4987455e-d22b-45ed-85bf-5ffd205c69bf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_493f8d6d-d110-48ac-94ec-bd3d013f1bf6"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c181d30-6d47-4bb5-8470-af8137d17292">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_213a26d8-5a21-4a5a-a36c-4e2103aec02d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79ee3ecc-fb14-4ca8-926c-e3c88947f230">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4ffbbe7-a3a2-4c75-a5b7-d59decfc10e1">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50e21734-cd2e-453d-9601-9bea072c7b31">D<xref linkend="sect_TID_3508" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_49c7a02b-e870-4d45-aa2b-e1726ee4b720">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ed47c8a-444a-421a-8bf2-3a90d2aba13f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b82da20b-2d98-445f-b1df-b8b819f34731"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03865538-6c23-493a-be1e-243a55e2a771"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88b004b8-e3e6-49ea-9d46-8ad528ae0c66">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bee7de5a-fd66-4c07-b282-383e2f85b999">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8cebcfdd-d890-44dd-88c6-69ae7ec583cb">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_862245e9-6099-48a8-a7f7-46a1a97d9c89">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8b68621-4874-48ae-918a-6af061bd785a">D<xref linkend="sect_TID_3509" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_988a3a01-8deb-41c1-ac55-b210664cf880">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_af6f9818-eb7a-41e3-a9a3-40f6a6ccaac6">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2dff5390-57a8-49b4-a231-80ca0d3e95d4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1472af14-4da3-4661-ae6c-e062643d46e2"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_212d7d7d-6e62-4804-8cdb-2186b4743041">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b693984-fb71-4a7a-87c0-5e3dab26bb0f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b79c70da-e5e4-499e-a61c-e561ca0d3ad4">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_578b2f02-d631-4f25-beaa-f311d980f221">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9af576a6-e529-4141-863a-9b9b492db9f5">D<xref linkend="sect_TID_3515" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_471982db-03ba-4689-9f8a-656f5a968dde">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f6efa90d-278a-4a3e-a087-4bc264979ce1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2d718da8-ca18-4f04-95c1-312714d2e010"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a24f35e3-fa68-43c5-a9c4-3e44a456a4ea"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_512fd1c2-8b4c-4097-b9fe-e81c40e4858f">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f76dc49f-afaf-423c-96a8-7d087b851c1b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_686781f3-65d5-44a4-a1a8-18f27f453559">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a55432f-10af-4e50-98b6-b330da6910bf">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88760e95-28c6-43d2-8b03-5d0e5594cfc7">D<xref linkend="sect_TID_3516" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e271cbde-f3f5-45cc-9038-0cff78793b27">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e8438146-1c30-4164-b158-bc68e416ac43">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_667abac8-3f7e-40e4-b279-227e0a8bb629"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f42fc41-2d13-4caa-8fbd-729ea97b45b3"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7a011340-0b59-4666-a61b-1db411c82e9a">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa12df8f-d1de-45bb-9765-ba69abcc2e75">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d7052e46-b6df-4c7d-9bd0-f7fb08954546">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70d4b88f-913d-4cbe-a929-539b43ab230f">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_18f34b3b-54b4-44d2-a5c0-d36467d26f6f">D<xref linkend="sect_TID_3560" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5f54b2d3-d378-42ae-9b62-4aac0a1ea368">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6830b647-1f3e-4bc0-904a-b9cf642c60c7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac1e3592-6930-4fbf-a6db-6bc36506de26"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e14a1f7b-506b-48de-b989-04d1453b44f8"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42c4c570-e188-4090-9303-40d78b8008b4">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc5ead2c-9050-445a-b999-4b076291cda4">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_64d8e836-051d-40d9-8ae4-ea20a0cdfc75">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f18f93df-f8ae-414d-9e7b-e506c29d4a64">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb012f17-e04f-41ca-b402-44b865dff0df">D<xref linkend="sect_TID_3714" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_62ead18a-2ad4-447a-b38c-0f6c0dcb434a">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_850c8073-a562-45ac-a434-336327f49c59">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f91853b7-c64f-491b-99de-3cdf0b131892"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3409cf34-c6f9-4b3a-bc5c-fbdaaf2ba72a"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_3466b16a-65a7-458f-981b-de0c58004374">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left">
                                <para xml:id="para_938b9add-4e2b-44e5-95d6-dffd44b5585b">Row 4</para>
                            </td>
                            <td align="left">
                                <para xml:id="para_c4fba1ea-61cf-455a-a120-95ad46470a26">Procedure Action ID allows linkage between the hemodynamic measurements recorded in this Template and a procedure step or phase recorded in the Procedure Log, e.g., using <xref linkend="sect_TID_3100" xrefstyle="select: labelnumber quotedtitle nopage"/>.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3504" status="3" xml:id="sect_TID_3504">
                <title>Arterial Pressure Measurement</title>
                <para xml:id="para_b5567e2b-b38f-41d2-8982-efa30d969d33">The Arterial Pressure Measurement Template consists of a CONTAINER, with an acquisition context of the measurement anatomic site, and containing systolic, diastolic, and mean measurements. This implies that the name of the measurement is effectively post-coordinated from the measurement name, the Hemodynamic Measurement Group container (procedure phase) name, and the acquisition context (finding site) value.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_988dc43e-7171-4b3b-b489-b027acb6a17b">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_cd9b9a6d-370f-4ba7-853e-5f45f74529cb">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_242ab0c5-9a04-4eb0-8d7d-3ad67a3d4b0c">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3504" rules="all" xml:id="table_TID_3504">
                    <caption>Arterial Pressure Measurement</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_47d16b71-30cf-45eb-bdc5-193af0926c83"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e2db5066-d3ce-4e65-86d3-2f68b121208f">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_957b667f-38b4-4adf-ac34-1a214199acaa">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f9c32e7-c350-45cc-9bad-068a4334030c">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bfce50df-f680-443c-8b8d-64b213337b0c">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0a5b7a5b-5626-4423-a412-21b7e565afc2">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d3895945-5055-4926-a4cd-beb94be01d4a">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0d3c05fd-3699-4b1b-9ab6-399c5261358a">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9557eb5e-9f84-4c87-88f4-b74b35192ddf">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5542e754-e0be-43a4-94b7-d187877e713c">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c27e3915-c176-41f5-8bad-09b080c6d45f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96790049-9987-4adb-a60c-ce8f54bd45b5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_266e6777-9440-469e-b2a0-115c2dd17ca4">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26384b8d-2dbe-425a-bf7e-2e36696079c7">EV <link xl:href="http://snomed.info/id/73002000" xl:show="new">(73002000, SCT, "Arterial pressure measurements")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_031b272a-de02-44ad-b6da-ec6a0870f3ce">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4856ba98-e406-4162-b450-b4acbaafd8f0">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3039b9c3-4036-4a3d-9ae9-10bdd059ecd0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43e98c4b-ad06-485a-8451-311f5c3d300f"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62abde24-5ca2-497b-96b6-e6d34fa137d5">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f71b244-1862-4f99-b866-d4112931d770">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72e1b591-89b7-42c3-ab4f-28a9bc5bfc65"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7553964a-39dc-48bc-98be-8b4b2216376d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b55b1303-0543-4825-8051-75dde739970a">D<xref linkend="sect_TID_3530" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_62a0c133-e699-4b80-99c4-2f1b5cfe54f2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5d7aed18-e27c-4cf1-bbeb-811e5d74ed8f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9fc48146-5639-459d-9a35-d02223ab35a8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0934df03-a68f-423c-89a4-db1e6e36401c">$LocationName = EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                                <para xml:id="para_fa9d0b4f-a73b-4916-aa7e-58f755440d80">$LocationValue = D<xref linkend="sect_CID_3606" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d7d22714-524e-4d66-94c8-268fe1d0936a">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54e3e21c-56aa-4ed8-b235-38791d42c3d5">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70f6dc1e-c4a7-40f6-b7b5-1d5ae150ec06">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c82f86b3-8bde-44e0-aee7-46e3602d0b26">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bede369d-c6a3-4631-b3ff-7aeb8c16de60">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_96f2ae89-c49a-4510-b4b8-a89d5f48039d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_89872207-8c57-422a-9ca9-388df708f6db">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0cab378-532a-4d69-8138-487cae16fb22"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_269e7f41-44e7-4837-9065-47f37cb4294c">$Measurement = EV <link xl:href="http://loinc.org/8480-6/" xl:show="new">(8480-6, LN, "Intravascular arterial Systolic pressure")</link>
                                </para>
                                <para xml:id="para_50f2b56b-7170-4bc2-aeee-b0fe7fafa452">$Units = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_68a4c01b-e815-46d4-b593-fe25b9916614">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5fe0d3a3-17bc-4ab8-b3be-6abc950eebed">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_902917ab-927c-4cae-9974-180bc9f7f88f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2cd8d513-ce29-4b85-b6cc-467b41437d91">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc238daf-f639-4d6b-869b-1df789037da5">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5b440dcc-55be-4fa4-bfe8-2c0a29dc797b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2f07d1c7-479c-40b1-9dbd-856c866f41e9">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e0fc5db4-d06c-4252-b16f-ef4026976401"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1e0450b-5f7e-4745-9839-f9c9e80fe74f">$Measurement = EV <link xl:href="http://loinc.org/8462-4/" xl:show="new">(8462-4, LN, "Intravascular arterial Diastolic pressure")</link>
                                </para>
                                <para xml:id="para_02ee3116-5f69-47ae-aa4d-4fe4d822ddc1">$Units = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8f06a2c-9041-4d10-b1ef-f3ad5596cbac">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab6e68da-3740-4fd5-b5f2-4c03eba1000e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a2ef2c1-e5a3-43ac-b4d0-bbcaf17668aa">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a2430f1-53ba-4b3e-968f-3aad7feb9514">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4066c107-721a-4b51-9db7-8d5d4c8fb153">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0652cd51-5e86-4a0d-b1e2-4b7bd391d15c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_06539f46-043d-40b8-8617-166a0b336da3">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e056e33-1747-4a1f-97dd-391106c6afc1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_938ac715-8d93-4141-8b77-959bd090c7ae">$Measurement = EV <link xl:href="http://loinc.org/8478-0/" xl:show="new">(8478-0, LN, "Intravascular arterial mean pressure")</link>
                                </para>
                                <para xml:id="para_ffe49fcc-e30d-4846-8ac6-67c46ee7373f">$Units = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_18132af9-9ff4-45fa-8bcb-b6a3cf32511c">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0c5ab4f-73ef-41e0-89ea-0775fd3ec686">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d44cfda-aa29-4b51-a118-99b726418817">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c40511a-3760-4040-9d08-cce07d6e2f2d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4dc56c54-c658-4b69-b52a-a4ea08556c7e">D<xref linkend="sect_TID_3550" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8625d97c-fdc9-4c74-8a4f-6ac90c54393c">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ad1fe4fc-121f-41f9-811e-144eee1d6976">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fdeb781a-1423-431a-b065-eece9b79c07f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8bda88d-cd7f-497b-b45e-17a23e8c091c"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3505" status="3" xml:id="sect_TID_3505">
                <title>Atrial Pressure Measurement</title>
                <para xml:id="para_339408fc-8ea1-4a3e-b268-015d51a85b75">The Atrial Pressure Measurement Template consists of a CONTAINER, with an acquisition context of the measurement anatomic site, and containing a-wave, v-wave, and mean measurements. This implies that the name of the measurement is effectively post-coordinated from the measurement name, the Hemodynamic Measurement Group container (procedure phase) name, and the acquisition context (finding site) value.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_77743081-5af1-4364-bdcc-4496d3f02282">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_277a97c5-c8d0-474c-b3da-fce0ec3b6924">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_c0d0cfbb-69e3-4102-b4dd-413be1f1ce0c">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3505" rules="all" xml:id="table_TID_3505">
                    <caption>Atrial Pressure Measurement</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f2654a3a-1feb-4faa-8b47-f4b5b037c860"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9f20260f-7c5e-4aa1-b9cb-f583e0642e21">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cef55e36-b2b0-45d8-944c-ad5e19fc1285">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69de2431-9e87-463a-8206-3f469e4210cb">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d7d91db9-6480-460e-9ba6-e227f3275806">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ca44abb8-dc2e-4b8e-8c3f-4aee38e28967">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_63aed035-fb19-4c59-8f4c-3c3b9493b9a9">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5ed9130f-3779-4619-acd7-6ae4109b6c3d">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fde619a3-8689-4905-ba74-b5e072d1dbe2">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06db1d2e-9a51-4147-9a00-df92ff7c7669">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5eb338da-92e4-42b0-9399-a183c92cd5c4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_208becf8-20bf-4e98-9ee0-de15c34cffe9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c403f858-9e89-4d7f-a97c-8d3798eb6438">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_967157dc-cee0-4a19-8d48-e5fff1b07cc8">EV <link linkend="DCM_122121" xrefstyle="select: nopage">(122121, DCM, "Atrial pressure measurements")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_31fbbb79-5762-40a0-887a-2fa3f7b93725">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69fc29b6-9dc9-4a22-b9b6-50c93097ec77">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10f93d56-8f6a-4522-939f-b349b383372e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_71e862a7-1dc0-4f61-8379-9c58b1f6e4a2"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f888dc1-d07a-4010-b06b-6625da6ad317">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e09e9137-26fe-41b8-82f1-118df58ebf6e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_935984d4-0fca-4810-b1ab-096aa868a7be"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e821304-d281-4315-938b-d48e9f4e7ca3">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1b9ff58-fd29-4382-84c7-9217e27676cc">D<xref linkend="sect_TID_3530" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4b7ad5cb-e2cb-47e5-8b30-bdce31655f52">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a3983f75-da10-446e-ae9c-d50d10b51ad8">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81173319-e21a-4858-8bb2-9b946fa93bd4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82f7dfb5-4056-41c7-975d-af4e167c421e">$LocationName = EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                                <para xml:id="para_d2b885cd-8cce-4843-8131-bb5fc2ecb7c1">$LocationValue = D<xref linkend="sect_CID_3608" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d600d944-edfb-48eb-aba8-4ad64fc24267">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c2f1cc3-67f3-4805-b0a8-02c805ae2974">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3cda5b9-e8b3-464e-84aa-f33d2cb7a370">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dcc05625-cf6e-4e88-8edc-fa8f5f1aec15">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_667d1749-afa5-40fc-b91b-738d865f716d">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b963c573-86c6-4159-9dfd-d8ae55691c5f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2e0c68f9-7fc2-475a-b986-9957b5da04a8">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f79596ee-8a96-415a-897e-6868aeebadba"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5254e9e-def1-408b-9436-170440125447">$Measurement = EV <link linkend="DCM_109016" xrefstyle="select: nopage">(109016, DCM, "A-wave peak pressure")</link>
                                </para>
                                <para xml:id="para_5f7be356-d9cd-4c1a-ae89-6392b4004638">$Units = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0633d1c4-e810-452a-bde0-c8a44e2426bd">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8814c92-9d2d-4c60-878b-e7b079c310cc">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d46ed31c-aa09-43a5-8710-d763ba396581">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c29f1ef-23d2-4e4a-957b-61f4b3c5f9e4">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa9c03e8-2d70-4523-b730-ac00a6524bb3">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_044273de-5fa1-498f-82cb-5740b50ea078">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0feafef3-0e79-4fe6-a577-5d61d1f0b24d">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f4bae97-b938-47a7-99fa-509ad7c5d188"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2d7b4b9f-b28f-482c-93ee-ee74334b1cf8">$Measurement = EV <link linkend="DCM_109034" xrefstyle="select: nopage">(109034, DCM, "V-wave peak pressure")</link>
                                </para>
                                <para xml:id="para_2cfb1ed9-a33d-49a0-ab56-6e82cddc05f2">$Units = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92ebef5b-80de-4a1a-9163-e93b9f29eef6">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be39739a-57cc-4bc8-ae09-1c4a6680ac9b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50964e02-cadb-472c-bd55-a433fb755a83">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c317d1a2-8f38-489b-bf11-db8169eafeab">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d446e2e-7fa1-421b-be8a-7c56a5625dd4">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_488ed52c-a836-4a1a-8d58-98a8bd239e2b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_66d05a52-6a5a-4271-a699-48cab044fd16">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e285e4d4-8c53-40d8-a840-835c80d09ab3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9effca44-4a7f-4ca5-bb37-9420d887c1e5">$Measurement = EV <link xl:href="http://snomed.info/id/6797001" xl:show="new">(6797001, SCT, "Mean blood pressure")</link>
                                </para>
                                <para xml:id="para_583cbe8f-f86b-4ce4-932b-b1c897f5280f">$Units = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7cd0d1e9-ad50-4136-8671-d9c983d978ae">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d7c42c5-b507-4577-a544-4cdb02dfce88">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_68b2ff61-2ee9-4544-a5da-66bc4d3543c6">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04e0ccaa-8119-4a4d-b9c5-229127ef430f">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5befb73-4930-49ad-836c-310a6f475e8a">D<xref linkend="sect_TID_3550" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_34f7c162-8397-4ea3-9378-e16ed04aa38c">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_776f9076-345e-4b64-bc00-0154bd5547bb">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1561fb34-2565-454e-9fda-1314939801a5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_027b78ad-512d-48cd-8640-9f2df261c6b5"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3506" status="3" xml:id="sect_TID_3506">
                <title>Venous Pressure Measurement</title>
                <para xml:id="para_22b84962-8427-4b24-a540-1d1318bfc6bd">The Venous Pressure Measurement Template consists of a CONTAINER, with an acquisition context of the measurement anatomic site, and containing a mean measurement. This implies that the name of the measurement is effectively post-coordinated from the measurement name, the Hemodynamic Measurement Group container (procedure phase) name, and the acquisition context (finding site) value.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_6074f53c-3117-4eff-b37b-3d1ff381bcff">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_6b74228d-6095-4f8b-9ed4-9e3c4640b056">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_19443a05-8b61-4117-9027-95f6e5fdafbe">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3506" rules="all" xml:id="table_TID_3506">
                    <caption>Venous Pressure Measurement</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5f921e35-f60f-4c09-844d-c93d04d3d366"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_06c75602-52eb-4fb7-8255-171d6c86d777">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7502f46f-23bb-4703-b6d1-1bf91c729d68">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69c800b0-9395-416b-b487-e757c940537f">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1c5b4329-e990-496a-a56e-5a8f867c023e">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_05387d2e-e97a-4e22-9980-1a0570d44ad3">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1753ae74-b70f-4c26-94e3-7e7da4b67a1c">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b1c67812-51d3-4342-b1ea-7ff3153104db">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0ad9996b-530e-4209-97aa-7ea4ad7968c1">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b083bcb-f7cf-4b1d-a15e-56dab8db4723">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ddbb7d2f-a694-42bc-9d42-33bf623a48de"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a45e6b73-5a23-4749-a00c-0996359bc7cc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3da43fc3-a04f-4003-b8f9-07d6029cce42">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad9891ef-7ebf-40bb-8c90-f42a623c9bc0">EV <link xl:href="http://snomed.info/id/31724009" xl:show="new">(31724009, SCT, "Venous pressure measurements")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a260aa6a-c807-48af-bcc6-cc8b7f12066d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_111360ac-560e-453a-9cd0-dca8f04f70f6">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c54e2be-c778-42f4-a3af-6216c233d54b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24b2123e-5dc2-423b-9bfd-298838116491"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f450751-b17d-4d0c-a346-19cc966f6a6b">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aced2add-a4de-4d23-b54b-ac48cfcd6e79">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_64fc67ae-f4bf-42c2-859e-b245b661032c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3de1fade-086e-4fa3-9ecd-1d3ea09dcdaf">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3612b1d-cdd8-4939-83e3-2eb5e6944649">D<xref linkend="sect_TID_3530" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_057d2940-f5cb-4527-868b-db796fbe8344">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3af75366-fa15-4e72-a5dd-ec9b25b55cad">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7fda9cc6-0134-4c1e-9854-01116c556f70"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb2899a3-28fa-414c-9872-02fb86c98cfd">$LocationName = EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                                <para xml:id="para_8a2244f9-0a4d-431f-9abc-5fd351cfb2f7">$LocationValue = D<xref linkend="sect_CID_3607" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_147afc4b-d730-47d3-bb33-a3620290144c">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_481bfcc9-8719-4202-9704-b93a0a0201e4">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04a9b4b9-b0ca-4563-9254-543ee241e352">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_937c1359-c631-4056-ab59-68512280d296">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63d5de1a-f8cf-40f7-8221-7657868bac5e">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_65fbd2e3-0ddc-4236-8536-c6e42e0863b0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c0c03be1-22ae-4dc6-a5d6-04029d6bd25a">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ceec4cf-c7c6-491d-b513-74e6af45e743"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80d62906-9fdc-4488-9c60-13dce6407459">$Measurement = EV <link xl:href="http://snomed.info/id/6797001" xl:show="new">(6797001, SCT, "Mean blood pressure")</link>
                                </para>
                                <para xml:id="para_385317f2-674d-43c6-b80d-c8f583784dce">$Units = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b3e5965-2e05-4bbe-a0cd-27b4c2241a6b">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee3a1285-5d6b-4178-ae3f-1bc87534a35d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b58a3758-6f25-405b-a8e1-d348995e75c3">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_49342d46-6ef4-48d1-8a62-592988126eff">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d8eb53f-08a7-4d53-86d6-2604b824f693">D<xref linkend="sect_TID_3550" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fd1115e7-e5bf-457f-bba3-cc15f430a2fa">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_656a17b1-61d7-47d9-a61e-520053e638a7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e821291-73c1-4d6f-9399-c862afde3843"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_76c923fa-0de1-4e26-85c9-f1bf80842343"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3507" status="3" xml:id="sect_TID_3507">
                <title>Ventricular Pressure Measurement</title>
                <para xml:id="para_4be00b67-2fa6-4ce0-8cb1-564a87dd59aa">The Ventricular Pressure Measurement Template consists of a CONTAINER, with an acquisition context of the measurement anatomic site, and containing systolic and end-diastolic measurements. This implies that the name of the measurement is effectively post-coordinated from the measurement name, the Hemodynamic Measurement Group container (procedure phase) name, and the acquisition context (finding site) value.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_8afa197a-946b-47a6-a4f5-d2e9b67367b3">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_0cf2f8c7-7449-4e2b-98d6-f2e57435f26f">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_d000b132-6eb0-4f3d-88ce-67ba725d6b6a">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3507" rules="all" xml:id="table_TID_3507">
                    <caption>Ventricular Pressure Measurement</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7941c34c-9af5-4e1b-af00-9a6544e1e0f5"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ba2b2dc7-d81b-4028-804d-b1b1887b410a">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d0e75f93-31b0-4233-983a-be98bc1a4250">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_07ce4d15-632b-4714-86e1-c9fd49abb5ed">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d574044e-2284-43da-b9b3-2ead03f3cd4e">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_478e9070-fdd5-412d-8913-691854883606">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6beeab37-f835-46d7-a55d-44e26a48d16b">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8abbd1b6-9cbb-4e44-9dba-a754d5d918cd">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_905096cd-76ec-459d-9739-81fe1d2d5060">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae954324-d1ad-45d9-b402-8151eff204da">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7484006-e0b6-486e-8868-56e890cdc3ff"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b01a4bbe-c798-48e2-8a81-21016744efe6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1c3e9f5-dc04-4bf0-a043-67677176c9a3">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3bc0cd01-913b-43f6-8ee6-a040d7eb53fd">EV <link linkend="DCM_122122" xrefstyle="select: nopage">(122122, DCM, "Ventricular pressure measurements")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e5611133-b403-49fa-bb74-aebba198cae9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_be29482b-0329-42b9-bc02-b9799f6bbb0f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a517767e-8bf1-49a7-ae02-011309d1ebc2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f7f17a07-0107-42f9-81a4-bd26ea35a32f"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_320c01d4-8323-43c9-b236-5670a3a7044e">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69002ba6-079e-4e15-9e89-e39f9becf62d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf8a989d-8dfc-4f11-8705-462b8efb22b4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_90145f72-01f8-4ccb-a6ac-da3ac8818fa6">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_302e1c4a-7611-4f34-bf2a-c27d736f87a3">D<xref linkend="sect_TID_3530" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6b69e383-ec8d-41de-ab0a-3ba48dbfe33c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_92012c46-d2b9-4538-aa57-9423171ab29c">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1b41e53-0449-402d-8e5f-c83a0c15cf8d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_68c68327-9cf5-4cd6-8b6f-5439357076f2">$LocationName = EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                                <para xml:id="para_afa08507-22ee-4ccd-8544-b1a46e9f110e">$LocationValue = D<xref linkend="sect_CID_3609" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_41efe6d2-8171-4acb-b5aa-66525107a580">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_848821c8-80c6-4943-8cd2-76aabda1211f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b7508dc-b202-4dc3-9aee-a83a73a275f0">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e843b78f-e18b-47f4-bc1c-4ec9478859cd">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a15101e7-46c8-46d6-9ed1-e9336f1d4d27">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d7e5c1d-b628-47eb-8aa3-909b66267d24">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eb1a532b-1442-41e7-a18a-dba90199da76">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4400cc65-0681-4614-8156-d3eab05f2aa5">IFF $LocationValue selected in Row 2 = <link xl:href="http://snomed.info/id/87878005" xl:show="new">(87878005, SCT, "Left Ventricle")</link> or subsite thereof</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9204fcda-cd66-4917-a85d-9156557e2054">$Measurement = EV <link xl:href="http://snomed.info/id/276780008" xl:show="new">(276780008, SCT, "Left Ventricular Systolic blood pressure")</link>
                                </para>
                                <para xml:id="para_c6869038-018e-4842-a62c-c9046804526d">$Units = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_957fb9fa-3599-471c-8a0c-b5d19d03655f">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba83712c-fb85-4172-9710-986965b12ccf">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b192cd21-ab20-4a0a-8e5e-d3f4d0388e3a">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec0b0b91-22cd-47e2-afbc-6077de128f41">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e982513d-53d9-48e5-9f3c-1ad8b30da251">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d7662414-56f0-4e31-911f-c6a84f9580e9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3345d139-76a5-43d7-80c0-31d33bf76f54">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5e1672d-61e6-4e8b-8b9b-1157549c68eb">IFF $LocationValue selected in Row 2 = <link xl:href="http://snomed.info/id/87878005" xl:show="new">(87878005, SCT, "Left Ventricle")</link> or subsite thereof</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_722324da-bad1-4d06-88b4-b63345f0e77a">$Measurement = EV <link xl:href="http://snomed.info/id/276781007" xl:show="new">(276781007, SCT, "Left Ventricular End Diastolic pressure")</link>
                                </para>
                                <para xml:id="para_36e83c03-1bd0-4e94-8f9c-f3d82825d257">$Units = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4eed884-4f57-4943-a557-1212bd9c5537">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c82ee5f-9ca3-40b4-b06a-b88c762dcb0e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f7fd95b4-8808-4096-99c7-af630c20452f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_096eff86-5612-4747-b198-6a88af9f7ae6">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4fcfe0e3-21ea-4286-a1e3-246e5cb0eb4e">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0db2ead4-88a5-4baf-ad66-e11a3dd2a486">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_238dd967-0c12-40f8-8a78-2ff65218be7b">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c576757b-a101-4cb7-a5ff-54141c93f1a8">IFF $LocationValue selected in Row 2 = <link xl:href="http://snomed.info/id/53085002" xl:show="new">(53085002, SCT, "Right Ventricle")</link> or subsite thereof</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a050088f-c43a-4a2f-9091-c049818ac681">$Measurement = EV <link xl:href="http://snomed.info/id/276772001" xl:show="new">(276772001, SCT, "Right Ventricular Systolic blood pressure")</link>
                                </para>
                                <para xml:id="para_0e1a64e7-e6aa-4eea-8e6b-b5f800e353c7">$Units = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e56164c0-bbec-4223-a95b-def020c2a139">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd267fbd-e881-4546-88a3-a90d0cb12b44">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be4f49ce-8278-421f-9782-b4e0e54724e3">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa113587-4a03-426a-a1da-4c5acf1ba29d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_77a7b71d-1117-4610-9570-70c17fd6dbb6">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bcea050b-7f96-499a-91ca-94221f38ba75">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_16170c0a-7c21-46e4-985b-173578331fc6">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65553b5a-12ad-427f-b002-00333099ec74">IFF $LocationValue selected in Row 2 = <link xl:href="http://snomed.info/id/53085002" xl:show="new">(53085002, SCT, "Right Ventricle")</link> or subsite thereof</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb7d702c-a1a2-4040-b562-6ae79dd69e7b">$Measurement = EV <link xl:href="http://snomed.info/id/276774000" xl:show="new">(276774000, SCT, "Right Ventricular End Diastolic pressure")</link>
                                </para>
                                <para xml:id="para_3f8e81c1-154e-494e-89cf-36e92b53386a">$Units = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48321a78-0c80-44fe-b4cf-324209008b2a">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f594a46f-7de8-4e74-a0e9-9af90d1a4580">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b221059-aaee-46bf-92c3-9499f827d101">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dac9694b-8bf0-49bd-9f23-7dffbc4a1b29">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b9f2a6ac-e974-4167-98f2-f0a250078bd1">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ab9bcf2a-2452-4a9d-8424-c249fac39b3c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_098931ef-4568-4031-afc6-c199743bb8bd">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04dc7299-26e0-4cb1-b53d-9d767fae7d7c">IFF $LocationValue selected in Row 2 = <link xl:href="http://snomed.info/id/45503006" xl:show="new">(45503006, SCT, "Common Ventricle")</link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5aee0db4-9fa6-4f89-a90f-920fed1e593b">$Measurement = EV <link linkend="DCM_122194" xrefstyle="select: nopage">(122194, DCM, "Ventricular Systolic blood pressure")</link>
                                </para>
                                <para xml:id="para_7654a5d8-e12f-40cb-b5dd-335fa9d71ab5">$Units = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_637f1658-327c-40d8-92b8-1b67b4ea7ec1">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c19b3b2-2eae-4e89-9242-38fdd0096df6">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5dfd97de-b0cc-49c0-88c2-1159dd5f5934">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_133ff7c7-cb25-4127-a20c-8369e1322edd">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_514241a4-e9bc-4c0e-8844-91a595274917">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b8860fa-5075-4600-a026-182adafa9dc3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ae24c2d6-1953-4ca8-bb5b-0d3519303522">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da7dedb4-b378-4ecd-b6b9-afbf13af59f6">IFF $LocationValue selected in Row 2 = <link xl:href="http://snomed.info/id/45503006" xl:show="new">(45503006, SCT, "Common Ventricle")</link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_296c0f8b-4873-4a86-832a-b55a969d5bca">$Measurement = EV <link linkend="DCM_122191" xrefstyle="select: nopage">(122191, DCM, "Ventricular End Diastolic pressure")</link>
                                </para>
                                <para xml:id="para_5551259e-c990-4214-af61-3820ee003e10">$Units = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d82a3101-30c1-498c-bbdf-746300da47c0">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6a28eb6-434c-4b46-a2d2-e7f0af733421">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d6e72160-1ab4-4bbf-bbec-a0bfdafad1bf">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6f6a148-7615-4572-b48b-81db986b74d4">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_64d986d3-1184-4821-83c2-64909a9c7b3a">D<xref linkend="sect_TID_3550" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5cc71f64-420e-42b8-ac21-86baa9757224">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aab7f3bb-ffc0-4e95-a53c-bbafb5cb9629">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a0b2020-c4db-4e2c-a655-ce6c72e38e3f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe8bda26-6043-4f39-b74b-6567da34a48c"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3508" status="3" xml:id="sect_TID_3508">
                <title>Gradient Measurement</title>
                <para xml:id="para_f0ed7502-7039-497d-8c8d-8c194f5a96db">The Gradient Measurement Template consists of a CONTAINER, with an acquisition context of the measurement anatomic site, and containing the gradient measurement. This implies that the name of the measurement is effectively post-coordinated from the measurement name, the Hemodynamic Measurement Group container (procedure phase) name, and the acquisition context (finding site) value.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_abd5fccb-35a8-4197-acc3-1951b57f6c70">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_eec0c828-a047-4195-a2a4-b98225a52383">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_dad09939-292a-4b40-b477-accd8e537c75">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3508" rules="all" xml:id="table_TID_3508">
                    <caption>Gradient Measurement</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cbe381a4-fd74-4cc2-8aef-73a020e107d9"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9b690722-9b5f-4f98-9e25-048e57667115">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c23c1c9-013a-4d09-8eab-a77a5941e9c8">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_feaae3fe-ecf5-431d-92a2-d9c3e6eecd30">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0cc905f0-aa19-4d24-b9ad-85c6d84c7f1f">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf1e1514-cbcd-4501-b19b-69ddb8900619">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8d9a4f5c-7589-44fa-b53e-1031bb654b82">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b3ebbb2e-14b7-423f-96f6-d3aec6a221ad">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5b161606-14e9-4995-8b32-dc3cdc8f9006">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b41f7652-56f1-45e2-91c6-60ec3c459054">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82ff37aa-f6f2-400b-a7f7-7a6df384971a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_745e91e0-7c57-44af-a3a4-753149611422"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e912cf7d-843d-4fd2-b8e8-5dc4cecfac3d">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_18b368cb-dca3-4f46-8f52-0777c7c5deb8">EV <link linkend="DCM_122123" xrefstyle="select: nopage">(122123, DCM, "Gradient assessment")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_61ed8300-ff81-4e48-9399-53e0c8f568ef">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7ddc36e4-0ad1-483c-b623-a4ee8d2e84fa">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3f844e1-f9be-426c-8617-6adba7307295"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06cc1c03-d555-484a-815f-132ac0345b8e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3c71e35-54a2-4274-8691-8ca12fe39185">2</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c96c38bb-3eb9-4626-84c6-8f35627c68af">&gt;</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85cf4d26-2855-4b2f-a3c4-c73d0266919f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9449c19b-0fde-4872-9862-72de19ec90d2">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4199290-ffdd-4bb4-bfd3-0b8eae167930">D<xref linkend="sect_TID_3530" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b80510cd-aa97-4cb5-8466-0318c6d38b86">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6aad9765-9b51-45ca-835e-36ac84e7c54c">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6970af2c-f662-4362-956b-ad9773247507">XOR with Rows 3 &amp; 4</para>
                                <para xml:id="para_e75251e3-94bd-4905-b207-248baebacf49">IFF single location is appropriate</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8be31359-fcbb-44eb-91e7-cd235fbc553b">$LocationName = EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                                <para xml:id="para_79b0f8da-170d-49b4-a080-a95293cf706c">$LocationValue = D<xref linkend="sect_CID_3610" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38a97b33-c5aa-4f35-969f-2f3fe5129420">3</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7a790410-5bbc-453b-bb1e-bd06f38b6b93">&gt;</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_090bb508-28b2-4fb3-bcb9-61c806997ffc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_90a61abd-6023-41a3-8dba-8996bf3c461f">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0b155b4-0985-4655-bac3-1708c0fac2f1">D<xref linkend="sect_TID_3530" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ba1dd91b-6040-455e-bf9b-0aff013ec539">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a687159b-142f-45a2-b9e9-d884cf020c94">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04b5c64b-fa6a-4d94-9432-59195dcf0162">XOR with Row 2</para>
                                <para xml:id="para_555487bf-0cfb-4ae3-9ca6-70758ec57615">IFF a dual location is appropriate</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_695c76e7-befa-49ce-9d50-1563d1ef672e">$LocationName = EV <link linkend="DCM_121116" xrefstyle="select: nopage">(121116, DCM, "Proximal Finding Site")</link>
                                </para>
                                <para xml:id="para_831d31c0-6986-44e4-b090-d0c3b0607159">$LocationValue = D<xref linkend="sect_CID_3630" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f56e064-ca92-4423-aa44-3f43f3ec5d61">4</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1a534d7b-8555-4e81-8357-e43b91620ac6">&gt;</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_12f931f7-27d1-4e76-b700-7b708b921754"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f621116-d87c-44b0-bef7-7f52c68f7b90">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba6ad95b-74b7-47d6-9ace-a25279ffd98d">D<xref linkend="sect_TID_3530" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bd4c3261-9644-4059-9527-b2c4ed54f994">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b3e12bdb-aec2-4cdf-9239-ce1e35e68b6f">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e90f8723-1cab-47bb-bc8a-7a19935cdfaa">XOR with Row 2</para>
                                <para xml:id="para_6726cb89-15c7-47b4-adcb-842fef74caf5">IFF a dual location is appropriate</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce1896ee-c746-453f-9bc8-b1047cb3922a">$LocationName = EV <link linkend="DCM_121117" xrefstyle="select: nopage">(121117, DCM, "Distal Finding Site")</link>
                                </para>
                                <para xml:id="para_5b0284c8-a724-4290-a10a-09ee8fe25373">$LocationValue = D<xref linkend="sect_CID_3630" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55b75b41-6d88-465f-8751-74492eed3fa0">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b1c6fbc-ce78-4554-843d-de109ca3627d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74eeab6b-80c1-4d52-94f3-664518433522">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd45121e-bcbb-40af-8c0b-fa589dac86fc">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97a3d204-1a13-44cb-97ed-0fe146124b30">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f41a1c5a-b608-4cb8-bde0-0ab9de5a73e2">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73c36213-a379-4202-b225-f4dc75ab4224">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_297339b7-92e1-4e69-a2af-8729d61eae32"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab5e96ef-9e29-4ec2-8aab-771d8f82aad8">$Measurement = EV <link xl:href="http://snomed.info/id/251081004" xl:show="new">(251081004, SCT, "Pressure Gradient")</link>
                                </para>
                                <para xml:id="para_68b805c7-7bf7-4d52-8b16-8cbe51db71b9">$Units = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_49c69bcd-3f76-4b92-a39d-495d906c8989">$Derivation = D<xref linkend="sect_CID_3627" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dacd584f-75dd-4ae9-a71e-ee715a27591b">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a203a10-8162-43d2-b439-d10bac73a464">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_893f5f65-5921-4a08-afa0-42f06c567144">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e51f064-678e-441a-af1b-268935a9ba40">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03ddc68b-a7ae-4253-8a2b-b60e25c71a33">D<xref linkend="sect_TID_3550" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_43aec77d-4033-46b0-922c-cd0b2142cb06">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_537e96cb-4d22-426e-b0cf-b15403a893ae">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dca4cd40-a89b-4310-866f-959c8d687abb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff12a9c2-a2af-43f9-808a-b1cc63406870"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_6a79c3fb-8222-4977-bbba-e15015d83ba9">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left">
                                <para xml:id="para_93d64b3a-7418-484d-9e75-9d86db3985a9">Row 5</para>
                            </td>
                            <td align="left">
                                <para xml:id="para_06efb84e-4ffc-4393-a781-aa23f1aeee3d">Is used to encode the gradient measurements. Uses <xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/> for the Content Item structure of the measurements. That Template allows an INFERRED FROM relationship to other numeric measurements used in the computation or derivation of the current measurement. In the case of a gradient measurement, the pressure measurements at the distal and proximal locations may thus be explicitly conveyed.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3509" status="3" xml:id="sect_TID_3509">
                <title>Blood Velocity Measurement</title>
                <para xml:id="para_1580c8be-c24c-4c88-b47a-3d3714c9b936">The Blood Velocity Measurement Template consists of a CONTAINER, with an acquisition context of the measurement anatomic site, and containing primary (not derived) velocity measurements, e.g., from a Doppler catheter. Derived velocity measurements may be recorded using <xref linkend="sect_TID_3560" xrefstyle="select: labelnumber quotedtitle nopage"/>.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_47917762-5611-40e6-9819-ed0b01af2e08">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_bff6156f-e299-4bab-8e24-609283800529">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ec12556c-a285-42eb-99b2-fce18f2477f6">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3509" rules="all" xml:id="table_TID_3509">
                    <caption>Blood Velocity Measurement</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c1b9467e-7f31-4517-ab5a-f579178ef411"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_493a2105-3a4f-40b0-8932-b285c0090370">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_91ddd46f-d211-4bcf-b97d-28e090261ad4">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aa0c5d89-66ca-43d5-a7e7-24b0da08214f">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cd92d792-be6b-43f5-8bdb-6ebffbbd4ac6">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bee13008-2f2c-4681-9c61-d8d9454b2b49">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_991b0c9a-7863-497f-8fab-0343ad98b482">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_07a57ff2-8adb-46ed-b1f5-7c462fcd6582">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8e04c7a5-07a1-4b8b-a82e-9009887f8f64">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b295eb22-9f6a-4876-a114-456f757a7879">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aefce395-83a7-429e-a934-0ec51804e2ec"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_640f7c5f-de73-42b5-93b6-e6a8e6930e16"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_94762f1b-c365-4ee7-b529-9fa688c912a6">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9979acb-1e7f-4687-af32-e497e4c6ee81">EV <link linkend="DCM_122124" xrefstyle="select: nopage">(122124, DCM, "Blood velocity measurements")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f5cadc23-da78-414d-933f-82b331aa45fb">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_537d8f8a-6221-48e6-915c-5a55cc3524ca">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b9733d0b-0187-4cf2-b230-198b2807b742"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_944cbba3-5bb1-4422-b1d5-9ae58c7fe663"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_680c4c37-c92a-4c0b-860b-2531d99fe8e2">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61d8858e-9aad-4b33-ac06-7c26e21720d6">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5eead7d-8a8b-4de9-b7f1-e95e3450be25"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3288353c-0c14-4da7-9607-14cf2a7a6902">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21ad44fb-bf12-4193-9889-54add59abac7">D<xref linkend="sect_TID_3530" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_56aaa752-6191-4134-83d6-527947b714b6">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_20ebe9d6-203b-4ddc-b777-88f3ef130081">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ba5951f-fd10-45f5-bf5e-1a215f6020f3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_acdd1742-bd36-447e-8da8-d686447e2165">$LocationName = EV <link xl:href="http://snomed.info/id/363704007" xl:show="new">(363704007, SCT, "Procedure site")</link>
                                </para>
                                <para xml:id="para_da614575-632a-4dcb-ac2f-f720ac69d046">$LocationValue = B<xref linkend="sect_CID_3606" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6439353c-e20c-4e35-b715-7f4f5cf148b0">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7df465a9-bbc5-4372-b0d5-90e5c61f8e36">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21c3a6d9-f88c-4e5f-978a-bbb511465ee7">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7829b8d4-60dc-4e3d-8c62-3d1a78266fb2">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c163ecf-1746-4e9e-a78b-452e3a50b83a">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_96d5e1e7-a896-413b-881f-7cb4940ef499">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eecbd1a0-a638-49ab-b02c-a1eae9f8c91a">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_917fd07e-5d36-46c6-8620-67cb6ebdf4ff"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4070e36-8ec5-45ea-9b8e-5a2f5ba25e4b">$Measurement = D<xref linkend="sect_CID_3612" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_dd9680ea-cc57-48a5-bf89-279948b3ef04">$Units = EV (mm/s, UCUM, "mm/s")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c55a00d8-46df-4971-8c62-bb999e531c3c">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a555009-959a-47c2-bc46-649b35259d2a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f5d4965-7e54-4ff7-a47a-f650defc7d3e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c673202-7053-43fe-a41b-0bb6411a4d37">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4110b74e-66d5-4b4f-a907-4d9c709ab85f">D<xref linkend="sect_TID_3550" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a52251ac-90c6-4edd-a710-9c35e8de2a01">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a000b5bd-ffd1-4d2e-b1d7-a7839dd68fe0">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0419548-e649-4f33-a390-a84e6635a9ab"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e8ea50d0-812b-44ff-83e3-0da904b5d55e"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3510" status="3" xml:id="sect_TID_3510">
                <title>Vital Signs</title>
                <para xml:id="para_58b654f8-b2c1-4811-8b87-9434f1aed3b6">The Vital Signs Template consists of a CONTAINER containing the various vital signs measurements. These measurements may be acquired automatically from patient monitoring equipment, or may be entered based on manual measurements.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_8a86883e-908f-4384-b0dc-94da8e90b4ab">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_c5d322dd-70ee-4c5b-92cd-17cd6364086c">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_950c6379-74cc-4c87-a744-ebc5c0772eab">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3510" rules="all" xml:id="table_TID_3510">
                    <caption>Vital Signs</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_99c7df40-0cdd-4058-a71d-2a27dac61260"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f613066-20de-4cef-bdb0-cd8bfceefc3d">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_370f5b26-3b6b-461a-ad9e-c08bc304b4cf">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8c0c60a0-ba1a-478a-93a6-cd92fc9b18fd">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_940ba65d-aeb3-46c0-adc6-7c5046bdbe64">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d970d47b-c1ad-4097-826d-645e0ecbe387">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a101939d-29e5-4cfd-8d4b-de84ff323e71">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_deb4c434-9bb3-4876-97db-d118f2c2eb92">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_143432a6-42d2-4e8b-b42b-0560e6284e46">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6eb83b3b-8657-4fb8-b042-08940b401c06">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0599429c-d308-4588-9955-2e5d437db1da"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6df221d8-9f68-485f-bf5c-1b427a632123"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f366198-51f0-4d41-ac9b-cc1f876e559d">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c9ec055-1bd3-4cb4-92b8-7615c3f6be54">EV <link xl:href="http://loinc.org/8716-3/" xl:show="new">(8716-3, LN, "Vital Signs")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cadf64bc-9192-4e84-af98-d62cd4960cf7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f74a8d87-f834-4d4d-bfde-99ccf1c92b3d">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59433854-e70a-452a-a17d-6092f4149999"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0023e45d-b827-4359-ac1d-a31263b4bd2c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_734272da-6520-46f9-9c39-bbce675c49c6">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51a8cfb9-98af-4641-b0aa-1d933e813a71">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa81cfae-7cc8-4ac9-89d8-49264b598c43">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_77184463-62d2-40ed-8674-d4c7a84a7d34">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_45621cbb-a1c3-442b-8a3b-1ac152a1625b">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8b63a5b1-4fad-4f26-bc20-8111a7d961f8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_096277a6-e1d5-43ea-b609-686bfdcc6934">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82e9ed0e-d4d7-4135-ba40-ec0292135036"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3bcb90f8-ea6b-40cd-8be2-cf9094cd76bc">$Measurement = EV <link xl:href="http://snomed.info/id/271649006" xl:show="new">(271649006, SCT, "Systolic blood pressure")</link>
                                </para>
                                <para xml:id="para_aa6e696a-bfea-4339-a4dd-9f1addeb92d6">$Units = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_73833d0e-a1b0-43eb-a44e-1fe436556bc0">$Method = B<xref linkend="sect_CID_3560" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9665b17b-7028-494a-81a6-43139e778a84">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7d93b85-6e17-4029-bfaa-8c495ad40428">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9788042-e200-4b31-817c-c1dbf9cfa08a">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ac0fa41-cb62-4367-aa79-92356636e7a1">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7b88eee-ec7e-40cc-9999-fe2b46e69d31">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d88499aa-76d8-408b-8582-348a7719e028">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d479cb35-2931-46cd-a45d-743aa2a71e84">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0ea8651-3c28-47f3-9dc1-37e3102b5b6e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f9c572d-28c4-4c57-8816-fa4e92511332">$Measurement = EV <link xl:href="http://snomed.info/id/271650006" xl:show="new">(271650006, SCT, "Diastolic blood pressure")</link>
                                </para>
                                <para xml:id="para_9cf3beb3-fa9f-493c-a124-7323d3ee87dd">$Units = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c413cb22-2d6b-4158-8d9b-84b2879e97eb">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46cc0dc3-9d10-4bcd-8c8d-e9f768c61e0a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_911ffa75-f27a-4656-ab2e-70035f4c964d">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c25c73d8-d7d4-4cc9-954d-1356b2342615">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_623ffb09-c25a-438e-b231-4508d5c67139">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_355cf866-879f-4152-94fa-7814f3dd5228">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_825e067f-5520-4dbd-8eb0-51bf23720cf9">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5155947-331c-46e3-821c-ba3a1ff7988f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d501e405-f803-4f39-841e-e364a117fe1a">$Measurement = EV <link xl:href="http://loinc.org/8867-4/" xl:show="new">(8867-4, LN, "Heart rate")</link>
                                </para>
                                <para xml:id="para_cda6717e-b3ab-4924-902b-f1397bb58b7f">$Units = EV ({H.B.}/min, UCUM, "BPM")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1eb3c2a5-6edb-43a5-8512-32b70c1810ef">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50821ac9-5c73-4dc9-91e5-59cbcb4da55b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4b43532-dd6a-4a44-a65e-c0e285123e82">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c3171195-0616-4a81-9be5-044ceed68c0e">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2abe8285-0948-4c12-8d6c-4fcad2dfef88">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_743b6062-742f-412e-a0a1-e80d7e678bdd">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_de17c066-cfbb-42a2-b585-edfe6d4e5507">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16397505-2a02-4e34-9417-e8909aeeb921"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e005b213-4e1a-44fa-9a18-c33c6a127e2a">$Measurement = EV <link xl:href="http://loinc.org/8310-5/" xl:show="new">(8310-5, LN, "Body temperature")</link>
                                </para>
                                <para xml:id="para_efc9f45c-9a27-4cc4-9287-6bfe0770ea79">$Units = EV (Cel, UCUM, "C")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_673df09a-4223-456a-8bd0-9fd4e7b9dc13">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5dcb7486-bff1-4687-a5c1-a7200604054f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_499236a1-db88-4d0f-b5ee-be844bc98898">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f69ecf70-6191-4bc8-aa14-54a90a08235c">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f0b5c11-8876-4d30-b7c2-a9b540cef93f">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_84895083-7e6c-47b3-a19e-f180ee9b8a82">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1f786f9e-fc88-4680-ad86-482591ff746d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b8c14ac8-2fe6-42dd-a156-f4070cd3c86b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5479548-50ac-4182-8fb4-a5663ce13404">$Measurement = D<xref linkend="sect_CID_3526" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_042e0d9c-45b2-467b-8212-9fc78bceaf37">$Units = EV (%, UCUM, "%")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25efbc43-3b79-4118-8478-5c93ec99e01d">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a462e2ee-9dc9-4d6f-a0b7-8c2c594754cf">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0e2bea8-da8c-4803-b6df-dbff83afc2d8">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3f8fd8b-b7cc-4a35-af54-2a1cc66990c1">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0807e664-b134-49bd-aab4-ce1ffa55f7e0">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3290695f-e5c8-42b6-80fc-36098f34bd6a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7300494d-1934-49a6-b6f0-5649a3b2f1c5">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d711623-87e8-404e-aa49-b514b9723d30"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46274406-c71b-416e-9261-50e8d436dfea">$Measurement = EV <link xl:href="http://snomed.info/id/86290005" xl:show="new">(86290005, SCT, "Respiration rate")</link>
                                </para>
                                <para xml:id="para_549ae205-a7d1-4b47-bcfa-ae5e5510beea">$Units = EV (/min, UCUM, "breaths/min")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09d1848a-fe01-4c31-b04b-dea845cc9c62">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cdcdc6a6-fece-46ac-acbf-e63a1303010c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f36002ea-91c3-4575-9beb-29beb0ac58e7">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51e28913-6bc0-4ce9-8b03-675e98a8da5a">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d5e028c-e714-447f-b671-2142cc24ad23">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6153448c-054a-4c8f-9c01-f7ba8064221b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3a2beaa0-0cdd-4c4d-bb1b-d435be2caf10">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2bcd1c6-c8c9-4143-afca-4fe85b035197"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a6aefdc-a9ee-4384-b1e5-38e971fe9088">$Measurement = EV <link linkend="DCM_122195" xrefstyle="select: nopage">(122195, DCM, "Pulse Strength")</link>
                                </para>
                                <para xml:id="para_0f080be6-2054-4da0-918d-b2fa88b5c291">$Units = DT ({0:4}, UCUM, "range 0:4")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_40a86b19-e48f-45f1-b6e5-6e69a3a314b0">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73f126f5-e89d-47f3-8f0c-64929c7bbb9b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c00d77a3-9e90-4e2d-b4c1-4ed8c5d644b1">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_95e25857-f407-416a-bcc0-9c28084e652d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e1df23c-a87f-4dbe-bd94-25c412733c93">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7dc66c24-1502-49c0-8cc2-8e2d76b3cc46">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d02b500d-7f18-4134-8677-8bb36e1d29ce">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c0d7156-77e7-4969-971b-b88126506d87"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5bf0c126-4e96-4bc8-898d-0ef45d8df3f0">$Measurement = EV <link xl:href="http://snomed.info/id/225908003" xl:show="new">(225908003, SCT, "Pain Score")</link>
                                </para>
                                <para xml:id="para_282a536b-0695-4c94-bb58-24a88c7d29df">$Units = DT ({1:10}, UCUM, "range 1:10")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96246cdb-d593-4987-a98e-37b9528f17c6">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92709d8f-db48-4f61-9f08-ffd45790c759">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d643e547-30c4-41ee-8094-07559a5d78e4">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc1a9497-b1bd-4d25-81f1-7da4e268cab9">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c787a092-d713-4731-954c-971b5b2f51f6">DT <link xl:href="http://loinc.org/8884-9/" xl:show="new">(8884-9, LN, "Cardiac Rhythm")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_59a20e1c-eea2-4101-9678-dd30b9591a65">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2387ba61-281e-4f14-88a3-613ec08fb281">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_258da122-6094-45cf-a171-9a102c723fa1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e377de4-032f-4c31-bb86-a804b20e491e">B<xref linkend="sect_CID_3415" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c931afa2-089c-4788-8b47-0194b4c35973">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8c4a1b6-64f6-4745-b5be-9dacef49f53e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d4962b74-af24-4dcd-9a0c-3fa9a04aacb9">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6efcaf53-4a71-4c09-9889-833f07c26c57">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9cdbaf5-8d56-4ece-b880-d95cb4d226d4">DT <link xl:href="http://loinc.org/9304-7/" xl:show="new">(9304-7, LN, "Respiration Rhythm")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_35d42f33-a0dc-4b6b-b636-146f5a27a039">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_731dadc7-eaf0-4b60-a597-0acfe288004f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f343fc8-b0b9-4e16-b7e1-de916fd9ffca"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a890f31-a009-472b-abba-59f39a969dda">B<xref linkend="sect_CID_3416" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3515" status="3" xml:id="sect_TID_3515">
                <title>Cardiac Output Measurement by Indicator Dilution</title>
                <para xml:id="para_50b95847-79b2-4a5b-a6ce-9081a1c75607">The Cardiac Output Measurement by Indicator Dilution Template consists of a CONTAINER containing the measurement and significant parameters of the technical method. If the measurement is based on a DICOM Hemodynamic Waveform SOP Instance, that object may also be referenced.</para>
                <note>
                    <para xml:id="para_7abb1118-2501-4eda-8f25-ac283eebec03">Fick Cardiac Output is encoded in <xref linkend="sect_TID_3560" xrefstyle="select: labelnumber quotedtitle nopage"/>.</para>
                </note>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_64dc2a12-9b7e-43b1-9d99-f44574103079">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_e0becf59-330a-4f14-9ca2-929e5c7f7902">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_9b81785d-8b18-4b14-94b1-8c33455a1f44">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3515" rules="all" xml:id="table_TID_3515">
                    <caption>Cardiac Output Measurement By Indicator Dilution</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b6b723c5-7740-499a-9332-8d3416fbb2d6"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_21f7fd42-391f-40d0-ba25-fe87d84e96b0">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4b698771-a0ca-4a17-b713-a96a72ec9f48">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b5b28841-4824-4a68-a715-f821f23cb595">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4acd9747-a6de-4663-9ce1-ae94e0b863f8">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1710e255-3bdd-44d6-8ecb-2838da959e39">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_62db7d86-02db-4660-b12c-2f560d315426">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_20fa782f-f3ac-459b-be2c-ccfa4a0d2baf">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_888511cc-c0e7-47b0-8b0b-d8891e32d0a6">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_960af203-e902-4972-8f61-0b86d098a511">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6acb3c13-9712-46ad-a61f-e897702fadc2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c9210e0-8f09-45ca-acec-eddf39b6d7a5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fcd92874-09d8-4c7c-a61d-45078d5848f2">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97063b2e-2b17-47f6-ab24-dd488e9069e3">EV <link xl:href="http://snomed.info/id/117610000" xl:show="new">(117610000, SCT, "Cardiac Output measurement")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_429a7f1f-15ec-4bcb-97c3-49b4e94bce06">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_db8ad6fb-1df3-429e-be8b-b032ad2c27c5">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5dc79663-437c-4030-931b-75be50bc932d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1159c6eb-ae5e-46da-b856-1a3da597d00f"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58474946-13b1-47b4-9579-3270b29c0dab">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88dacc2f-7729-4007-a89b-0276333577e1">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4f16027-06e1-4404-9dc1-39cf50ae2d57">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d4129e8-d65a-4ca5-a446-b9f467f56939">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e0b29fb-eb40-4c76-ace9-f36b2a18dab0">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1de9187b-8e54-4a42-a586-8feb613da164">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_976116f6-ff3a-4235-aecc-4ad9d7df7583">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_230e948b-1025-4da8-9c3e-1128b2c272f0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c82df1ec-cf82-480b-8ff7-b17788a9b8b5">$Measurement = EV <link xl:href="http://loinc.org/8737-9/" xl:show="new">(8737-9, LN, "Cardiac Output by Indicator Dilution")</link>
                                </para>
                                <para xml:id="para_c1d8819a-580a-4654-b503-0fe695a04683">$Units = EV (l/min, UCUM, "l/min")</para>
                                <para xml:id="para_41b94cae-a34c-4344-956f-a0de6ee58b70">$Method = D<xref linkend="sect_CID_3628" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_d0ad3785-65cd-49a1-988d-82237bc803d6">$WavePurpose = DT <link linkend="DCM_121112" xrefstyle="select: nopage">(121112, DCM, "Source of Measurement")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c4ec765-3445-4b23-bea5-5bc1879dc508">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a79bab40-80f0-4187-add7-0c9a075dde43">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d0f6e20-abb6-44e4-9151-a572d138caf7">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2be28e29-c681-4e16-b967-707818b86b42">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22b76f42-2b46-4637-af8d-c9159fe13391">EV <link linkend="DCM_122319" xrefstyle="select: nopage">(122319, DCM, "Catheter Size")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1940837a-bfb3-44b8-ad1c-c404e3c01c7e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eef422d6-088d-4468-af33-908aaebd6fa9">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_786e283c-9505-446f-8f09-38e9e457bfdb">IFF Row 2 indicates a thermal method</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a4a1fcf-fafd-4bdc-a89f-829f69595dd7">UNITS = D<xref linkend="sect_CID_3510" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cbe2be64-9965-4800-87de-f586a131083a">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d6f3fea6-17e3-4fce-9422-306c427d7a1c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b939e61f-3115-42d3-b3a4-f528083400a7">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4392bad5-f662-4e85-a988-735ecb30a774">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8affefc-f2e4-43f2-a9d0-085d58ca08f9">EV <link linkend="DCM_122320" xrefstyle="select: nopage">(122320, DCM, "Injectate Temperature")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85ef508b-5cc6-46c0-8ad6-c805bceded56">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_580bea0d-0a89-4837-a792-d75530f26642">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_420dc403-6b7b-4c6e-a4a1-57b78816e52f">IFF Row 2 indicates a thermal method</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba294f7d-a256-41c7-9834-2c968f8aaa33">UNITS = EV (Cel, UCUM, "C")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f35ae67b-504f-45d0-9d77-f611680c67c6">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97d7455e-12e4-449f-8fbd-a61dcb23f1f1">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6adb5332-8349-41a0-a04c-bc14d62c82d6">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_138c066a-a69d-4ee3-89f5-f934e91d532e">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3da06e16-4616-4b36-8e8e-3a8e0ce2f210">EV <link linkend="DCM_122321" xrefstyle="select: nopage">(122321, DCM, "Injectate Volume")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a3627706-1762-4bda-a4d8-033b8f7651c7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8077c0df-3e5a-4bef-a8d0-2ac6b12b3927">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7134d0b-8274-41e6-8e7e-5e9abc04b0ad"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a58796af-0fae-4cec-bcf6-24b6ba437d6f">UNITS = DT (ml, UCUM, "ml")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_539f8230-e53b-4c41-a990-2f24530d715d">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_115b6821-1176-4664-bcf8-15dfcf68a1b4">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb9f4b9f-afe4-4ea4-9b7b-65e2f772bb34">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb889152-da7a-47a3-bf37-cc553f7ae3ef">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c1f563b-d267-4385-930b-14f204be4c03">EV <link linkend="DCM_122322" xrefstyle="select: nopage">(122322, DCM, "Calibration Factor")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e5e9ef9c-9994-4e37-a77f-0427092f4fdd">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aaf2bce9-5ba0-443f-9d7a-eee3f9cd22c1">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7db74fa5-6d5f-4a60-94c5-c2a6a71d8ea7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3748435c-33bf-484b-a39f-94c6fd571321">UNITS = DT (1, UCUM, "no units")</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3516" status="3" xml:id="sect_TID_3516">
                <title>Blood Lab Measurements</title>
                <para xml:id="para_064a9829-cf6d-4c19-b27b-aaeb77bd780d">The Blood Lab Measurements Template provides for the recording of measurements made on blood samples obtained during a catheterization procedure. The type and anatomic source of the blood is recorded as acquisition context. The results from the blood chemistry measurement system are quoted; the measurement names may be pre-coordinated with the type or source of the blood, or generic measurement names may be reported. In the latter case, the full measurement concept name may be effectively post-coordinated using the recorded acquisition context.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_b0e4d562-d5b5-462f-9b49-7005e1591acf">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_c179fe96-63ec-48f1-8daf-fb2f81cf962b">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_9ab22606-d184-4372-8a02-385eae2b9506">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3516" rules="all" xml:id="table_TID_3516">
                    <caption>Blood Lab Measurements</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4055db5e-39c6-47c2-ac44-c1e1d23bea6a"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3ccbae64-05ca-477b-b4fb-abe38756aab9">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_518f1d06-c719-4f3b-b303-d0452cfa8419">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0e994b76-c48d-4863-85f5-6da45d2e3d36">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3948c3a0-e03b-4c3d-b8bc-770c8540a49c">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4097301a-eab0-4924-b5b5-05882f2f81d1">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_456b4c09-f3ad-49a6-b72f-f56739c7bc93">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b0fba8e8-9e18-47e0-ab08-428e76082955">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_12197d51-0b10-4dbb-8ef4-3cce28ed8a82">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_695388f5-78ef-4cdd-b22b-d084c36216fc">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb9c7c44-a954-44f0-b71f-38427e66c940"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7ed29fe-feac-4cac-9c44-a5c78968ee76"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc076f77-d087-4702-bfcd-70414aa95a81">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5830835-bbf1-4b33-b511-3ecf358ce776">EV <link linkend="DCM_122125" xrefstyle="select: nopage">(122125, DCM, "Blood lab measurements")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cd86401c-697e-42cf-9eec-0c9a303a642d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d6212a32-cf7e-44b2-9e49-3434737ac7b5">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_799e09d8-a7f4-47c8-bee5-c0d777dba740"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8366db99-eeb6-46fc-aeff-4afbbcbe34b0"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d6ecb18-19c8-4252-a569-d4bb87345c79">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a289d3f9-ca68-4324-ae22-d54497ac99f6">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a235f13-4332-4a29-9812-c40ffeddefef">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96c47450-58db-4d98-8a09-fcde880dc486">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cadb6d81-5406-40fe-964c-875c4ed3f3e3">EV <link xl:href="http://snomed.info/id/371439000" xl:show="new">(371439000, SCT, "Specimen Type")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c429d10d-08f8-4041-b85d-cd4f2f535f63">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3c801718-d17f-4576-923f-764803238c8b">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_800c55a7-8f83-4769-834f-e920eea661a4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0524fde-c094-4afb-88df-1b6910a0d934">D<xref linkend="sect_CID_3520" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e479a0c1-922c-481f-92ad-3278431e5f66">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd49d00f-d83a-40d0-b219-1ea3b5e4539c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5930497-5c6e-4d47-bf96-cc2167e030e5">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de24edc9-5601-46e0-9a66-2dad112a7692">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4054e41b-040c-414c-8c97-c68d25f1ace4">EV <link xl:href="http://snomed.info/id/363704007" xl:show="new">(363704007, SCT, "Procedure site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bdb6508d-2d14-467d-9a50-b9ff84ef0e33">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e86ab515-6d51-4cd0-96f7-1b83af1a87fb">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f24b4e80-103a-46f6-a47c-fa7ca6a43521"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5edbf4a-4e95-4166-bd8f-81226ad35f35">B<xref linkend="sect_CID_3630" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c73d412a-3459-4129-98d9-aa83448a4afd">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1d090ed-88a1-415c-84a5-1d81aea0a1b7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_237a9031-48fc-47e0-89e3-9c249c11e04f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0774486a-1314-42ca-be28-237e821e92b4">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1acc6ee4-f21f-455d-b8b1-1ec1bcde1960">D<xref linkend="sect_TID_1000" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_89c38b47-7491-45d8-ae6e-60803780a0cc">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_be844a0c-4e4f-4c9a-9d62-998b31134b31">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec5b2f29-1567-493b-a7b6-a24be7e6f10b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d48dded-3857-49ad-a253-e5458c8d8daf"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e679a420-d2d2-4bac-9390-3b111bc0a26a">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7bbb418a-08a4-4648-9ed4-edd1f1162e97">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_318a7a69-dae4-4477-b596-d25c78355c75">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_47b6eafc-2149-43ec-9868-73dda84bd6b7">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f18b95e1-474b-44d6-b6ac-cce38eb59222">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8fd1e641-2133-4c6a-afc0-fa5f53535765">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1e14b0b6-6acf-4c2e-8340-4c3e47a18856">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c1b53f8-7bfc-447a-ad3e-d974ade34aa9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d9a9886-8791-4578-a62d-108d91064176">$Measurement = EV <link xl:href="http://loinc.org/718-7/" xl:show="new">(718-7, LN, "Hemoglobin")</link>
                                </para>
                                <para xml:id="para_72afff61-8b77-486a-ac8e-3c03d9ad1f51">$Units = DT (g/dl, UCUM, "g/dl")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_568f0459-f7d8-42c5-b462-7855e11bd33b">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d1ea55a-ee70-4936-802d-4d8e4de18d84">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d70db4b7-012e-4e20-8d39-ee00e9fa49a4">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e73f2e8c-cf81-4150-a818-d9cc34231912">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_817c9801-19ee-4a05-9e7d-2124c3497315">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_91060471-e6d6-4662-97be-47a0dccf1fac">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_20af3ffc-4ae6-4616-997f-2961a15a391a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7d26b0f-56b6-4ee4-8cdd-067fcc203cec"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb6570d4-381d-4e6d-8a44-a64501cfb06d">$Measurement = D<xref linkend="sect_CID_3524" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_f266ef1c-9ab8-4fec-b0d0-3a9d562c4ea6">$Units = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5f4e919-f258-4b8c-a83e-2bc9b99646c2">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d54b17af-c624-4d11-a30a-3cd5a4d5409b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83c4fe52-1381-4d84-8e9b-9c038583d537">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e09a82f7-2262-4960-8fe1-16f40f5e1ab2">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04cb53ba-dbc1-4d93-9298-68677ea76927">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc38ad7f-df64-4093-bfa4-4aae5a18a61c">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7bac216c-f55d-4a21-8971-c1cc57f18b73">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a2a5d03-6563-4528-956a-a34acbccb93a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_afbcaf11-e6dc-4936-90dc-8e58d6d342d8">$Measurement = D<xref linkend="sect_CID_3525" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_30d4eedb-1c52-4756-a3af-207a60533c5f">$Units = DT (ml/dl, UCUM, "ml/dl")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0841945-29b8-404f-8924-c6a976b9e6b8">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7574519-6799-43f2-aeec-dbb5f6b0252c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a17bfa98-5fa3-437c-aa59-731e8f8d9ac2">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3dadf218-9d79-4671-a2c6-223daea640df">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3068fc23-ff34-4f68-a82e-bfd652be4837">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9fd9144f-0e4a-48fe-8584-7962c2886095">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a23abf45-6991-4d49-95e7-eb4c2ce9eceb">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba53d188-2c02-4b37-9d64-cffdfd4c2628"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_77dd908c-d5a6-4920-a3d2-13866bc48885">$Measurement = D<xref linkend="sect_CID_3528" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_4e80e627-3667-4982-9049-cefbf61ea188">$Units = EV ([pH], UCUM, "pH")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_249eca83-fa9c-4024-ac78-7e0e4bd338e3">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ad327f4-4d27-4d52-ada0-08e130095dac">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d10414d3-f54e-4e78-ae3f-2518667bd168">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_039bd7c2-ef81-4569-a1cf-a9ee5cfa1a00">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8653d524-77ba-4a65-a692-f7e5a22f349e">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8e5b4a7f-a00e-4017-b2c7-d86a8bc06693">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0ed288ce-fcc6-40c0-b7ca-977d80e04259">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17a7ad0a-63e6-45b7-a94d-e5f893378071"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c89f245e-4c72-45d7-890d-2443905f778e">$Measurement = D<xref linkend="sect_CID_3526" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_a406ede1-d030-46e1-b5c7-2aeac628e3cc">$Units = EV (%, UCUM, "%")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3edb8d27-732f-4408-911d-9b557c62ddb2">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e6cb497-f903-43b9-8bff-1ac090c48a85">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9560d56a-8d40-4e48-a3e1-6c964659ff6e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a57920e-3be9-4000-9a75-455f4a49dece">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9479c432-cfdd-45ad-af66-4ba40553df43">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7dd1c492-9d1b-452c-9516-a66967b49df1">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d9239e54-fc24-4014-be59-2c3654ccb507">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0af2ae0c-b97c-47b3-b9f8-2ef1d6895cb0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_510bbf99-9130-41b8-8ac8-85005f55d837">$Measurement = D<xref linkend="sect_CID_3527" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_d90a2788-b540-4fb2-8b99-1e364243d61d">$Units = DT (meq/dl, UCUM, "meq/dl")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83507497-d0c9-4547-a753-07c3f8e043a1">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3fe33594-06b5-4e2a-90c7-92d75f552fd3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_068fdfc1-1c3a-422c-9b20-2ceadc169041">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_746e4448-228d-404d-aadf-240f12ccbc03">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_41ec2fe7-be1d-4047-a773-40dd8ee4e8f4">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_99d71184-c3bd-482d-9509-7976403a3699">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ece4fe3-99c6-41de-b327-906efef6f253">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de06f88b-7380-492f-894e-aa7c5e47c476"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1da93a9-37eb-43dd-b77a-99629b4728ac">$Measurement = EV <link linkend="DCM_122183" xrefstyle="select: nopage">(122183, DCM, "Blood temperature")</link>
                                </para>
                                <para xml:id="para_e926dd30-bb05-4c53-be55-34381549774a">$Units = EV (Cel, UCUM, "C")</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3520" status="3" xml:id="sect_TID_3520">
                <title>Hemodynamic Clinical Context</title>
                <para xml:id="para_73cb4c16-9373-4d02-9012-0758058ddb37">The Clinical Context Template allows the recording of information about the patient's clinical state that may affect interpretation of the hemodynamic measurements. This Template includes several coded conditions (e.g., complications, drugs, physiological challenges, etc.), each of which may have a Concept Modifier of "Relative Time". This Modifier indicates the temporal relationship of the hemodynamic measurements to the conditions recorded in this Template. E.g., the Content Item structure:</para>
                <para xml:id="para_4f350fe6-6f70-4f44-8f1a-f670370907b2">[CONTAINER] "Findings"</para>
                <para xml:id="para_ec5ba7e0-ba60-470e-9b14-3b6cb5cb47f1">&gt;HAS ACQ CONTEXT "Cath Procedure Phase" "Post-intervention phase"</para>
                <para xml:id="para_65152ebb-1780-4176-8479-49e024a8ef67">&gt;HAS ACQ CONTEXT [CONTAINER] "Clinical Context"</para>
                <para xml:id="para_732f5353-8052-4918-b2d4-d1d8be80f379">&gt;&gt;CONTAINS [CODE] "Complication" "Arrhythmia"</para>
                <para xml:id="para_f26c9fa3-19b3-48d7-86d6-847774cddbc3">&gt;&gt;&gt;HAS CONCEPT MOD [CODE] "Relative Time" "After"</para>
                <para xml:id="para_d37e0e5f-28ae-40db-a211-3db68c65dbc5">&gt;CONTAINS [CONTAINER] "Arterial Measurements"…</para>
                <para xml:id="para_6f88a3e8-5077-426c-8be8-ff19742d0dba">conveys the semantics that this group of measurements for the post-intervention phase of a cath procedure was made after an occurrence of arrhythmia in the patient.</para>
                <para xml:id="para_1554a29c-71ca-40c9-83f4-9709004f1d9d">In the absence of a Relative Time modifier, the acquisition context is during the identified event or state.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_cee9e1ce-65dd-4fed-8ded-c0f1fb518460">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_c925b85f-b2a3-478e-a2bb-5b322b315daa">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_fe8f2598-2a5b-4ab1-8f7e-4a995dc6aa63">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3520" rules="all" xml:id="table_TID_3520">
                    <caption>Hemodynamic Clinical Context</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_09991761-44f0-491d-bd04-7087758f5797"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bd88bf46-9d5f-48ad-ba97-8d1e0a0e2e25">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3290821e-ef14-42f7-870f-6d575b47cd56">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a541d39c-819c-4e94-af26-3605fa17ae35">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_81b7f8c5-f937-4851-a57b-434ae500e77b">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b6c6778f-176a-4b75-a527-1af7158f6038">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_acc674d3-871c-454e-b9f6-35f7c07f6942">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ecd2049b-3c74-43c4-aecf-ea9494570e10">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f73d3c9c-c654-4ac1-94a8-490279342788">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_758f4e9e-afa1-4ee9-86ab-f73a4c370158">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a0deccd-d1a1-43dd-9843-20074f9c3937"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a906cc8-0c39-4120-909a-b9dc589b41b8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97dc4e0f-d26c-48f1-a487-d26480322b46">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_32705828-a534-43a6-b45d-fa7f56df6da1">EV <link linkend="DCM_122127" xrefstyle="select: nopage">(122127, DCM, "Clinical Context")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ef76a189-b21f-41a9-bf3c-0fb7489b0025">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2be0feb2-206e-4099-ae89-75388b62a828">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43dc987d-af2f-403c-a957-545b10e29131"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_64b65e3a-2efa-4943-a738-69339967a27e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37ad50b2-ef76-48f6-b509-18ed6b71f663">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3dd59011-0d91-4e96-85bc-ea693e2416ec">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_200b8535-5b65-4c57-838b-5d83c3219b40">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08066651-2665-45e7-9f6e-5e076f447744">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50359bcb-5397-4f5f-ba99-3f68977f6750">EV <link linkend="DCM_109054" xrefstyle="select: nopage">(109054, DCM, "Patient State")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_48dad0f3-9ef6-41bf-be05-ed306fe3a1cd">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f08443a3-073a-47ae-aca9-4b93e30159b1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6315fa60-2ef9-4600-b5a1-a80b4cf4d56b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f7bc618f-5f6d-442e-80c3-7245ceea7d63">B<xref linkend="sect_CID_3602" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dec1e88d-d6f1-4cc4-8686-e2797dbc8a60">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de809e7e-0e69-4b7b-95fa-1aca940ab2ae">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_131c059b-9b73-464f-9c15-7fe7ac14f795">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb0a338e-8b91-49ef-b7ab-b94e8b40bf09">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d2216f1c-0f85-42f7-b2f0-48b952031d2c">EV <link linkend="DCM_109054" xrefstyle="select: nopage">(109054, DCM, "Patient State")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f4cbadd5-7d0f-4fcf-bb17-40394d3a06da">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f8070c33-3e2e-4493-abeb-ac510adace70">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa4a23cd-292e-4668-a3bc-a68b066bd616"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fccfe2df-2679-4f7a-9d19-7c0104e193e1"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_708a8974-f8f8-458e-b774-24b91ae9c963">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_610c87bd-db93-471a-8133-0ff39d0a1fe1">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36ddebf0-c12a-4eb4-be5d-825166ebfe69">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6182e1fd-619e-4553-b351-afbe93b76d0d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7cc45f44-dac5-440e-95ef-c7a4c498e3fb">D<xref linkend="sect_TID_3521" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ad77182d-4b65-4504-aeb1-277786c63580">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1320dd8e-cde9-4706-8f77-20c5ccf58e62">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57ff50b7-e7f8-4967-991c-c3906a06a409"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96e56e09-d3e9-4292-98ad-5f1c51a52e0f">$ConditionName = EV <link xl:href="http://snomed.info/id/116224001" xl:show="new">(116224001, SCT, "Complication of Procedure")</link>
                                </para>
                                <para xml:id="para_23d7ee80-4ea8-4ae3-9de7-cd2cb173c3f3">$ConditionValue = D<xref linkend="sect_CID_3413" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_772f42a5-e46b-49c7-b0d8-5310876dfd6a">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f081ed9-cd95-48b7-ab7b-d350a978f9a3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6085b63-6e61-4772-a4f1-11a091464ea9">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c22969ec-b43a-416f-95c0-481e32209c9b">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b83018e8-ce46-4d5b-a1fb-b7630b3a2b9a">D<xref linkend="sect_TID_3521" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cd15e875-769f-4819-8b12-23bc53554103">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c6dcf6e3-2686-44ed-b82e-a55c530655f2">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df5ac678-00c4-42c1-a8bd-eab3a15b853f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9865f6c-bfe5-497b-97b4-4e08524327fa">$ConditionName = EV <link linkend="DCM_122086" xrefstyle="select: nopage">(122086, DCM, "Contrast administered")</link>
                                </para>
                                <para xml:id="para_1cfc9161-8b1e-443a-b38a-034b74905d74">$ConditionValue = B<xref linkend="sect_CID_12" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b2f05b7-56fa-4cb3-939a-92e0094cd762">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a8b0105-e0d8-4b97-9ad5-c2a0efec09fc">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_244e72d6-41e3-4b49-85dd-4f1cddb20f2b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_543e4fa5-6c9b-490c-a4e2-418d740f259f">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_53bc9aae-32d2-42b4-985f-8cc61427fcdb">D<xref linkend="sect_TID_3521" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_373c00cc-70fd-450c-9965-44d0a8d2ed3e">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ee33fbdc-8ac4-43cc-9a23-ac50375ad6f8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8df9246b-b038-457a-8d6f-4699430b8358"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d96890c8-a0a3-4753-a574-550c4280276d">$ConditionName = EV <link linkend="DCM_122083" xrefstyle="select: nopage">(122083, DCM, "Drug administered")</link>
                                </para>
                                <para xml:id="para_e9f5a61f-d209-4252-ab40-7a7ce10f1ecd">$ConditionValue = B<xref linkend="sect_CID_10" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_075ba177-9278-4686-939a-ff01094500f8">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f52cbf71-dd1a-4c8b-ae8a-15b36fd5c417">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4e6bc98-7abb-4a3a-9891-3778f199842f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_106fa37a-447e-4a41-bc63-fcc174caa274">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e2c2a33-3f1a-4e41-a87c-9b35e8b75c55">D<xref linkend="sect_TID_3521" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dc1769d9-7f7a-401d-ac1c-3a2f4e01c8fb">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f1f25913-e0f3-43a0-9ed6-ef401f1761ae">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a23af2ad-0a14-4afa-8908-977c42ec9625"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b24e1dec-0019-4e68-a622-795bf0046a89">$ConditionName = EV <link linkend="DCM_109059" xrefstyle="select: nopage">(109059, DCM, "Physiological challenges")</link>
                                </para>
                                <para xml:id="para_ac621a62-c1cf-453c-9bbc-f5dc1b05f39f">$ConditionValue = B<xref linkend="sect_CID_3271" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_574b483d-a62b-42b0-93c0-836059238212">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7fece3de-421d-4300-97ef-4da00a9210ed">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3cf329d1-2f43-4120-9860-2167d683ff33">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2489543d-e7ed-4779-8ec2-0e7d8c59bd9b">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dcf0aa25-d378-4ad8-be1e-f797f0b7577d">D<xref linkend="sect_TID_3521" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6abf274f-b28f-4b96-9000-03fd147d314b">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bf0102c3-33bf-4d78-8906-47ebdb94d48b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1614056-5926-4fb1-9f58-4766424b345b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87dfef46-8d04-4f7d-8182-0c772cb9ce45">$ConditionName = EV <link linkend="DCM_122138" xrefstyle="select: nopage">(122138, DCM, "Circulatory Support")</link>
                                </para>
                                <para xml:id="para_1892b4b6-9b15-4110-b5eb-a6edb46610ab">$ConditionValue = D<xref linkend="sect_CID_3553" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4daafc6-fc1b-4a52-91ed-3b6ec1454c72">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c9b68804-ea09-4944-9db1-e0d12bbb91e3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5854329-cf62-4fc6-8bb3-4b29f43e5bc0">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_137b4248-9219-48b8-84d7-7f26b5d19549">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4051bbf-b08b-4525-bcdd-d590bdc56b18">D<xref linkend="sect_TID_3521" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9dd4376e-fdd7-48bc-ae8c-e40ec796dfa8">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ca8dd435-f82b-4ab3-a8ce-57d48677354f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c224af83-0bca-44a1-8aaa-0e69982048be"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6125d960-b50f-410e-9f92-d79284325a0f">$ConditionName = EV <link xl:href="http://snomed.info/id/266700009" xl:show="new">(266700009, SCT, "Ventilation assistance")</link>
                                </para>
                                <para xml:id="para_b3b5da57-3c9b-47ec-bd08-5ec5709d81b9">$ConditionValue = D<xref linkend="sect_CID_3554" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6bd664c1-d698-47ed-9391-34804b46651c">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_956ed7c0-6080-4ac1-8709-f40603a32dc6">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_18b9df7d-ca16-441e-b988-4b16ada381dc">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8199d1c7-336b-427f-9965-8ef6137caa42">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2917afcf-7956-42f1-910f-0c3098863f37">D<xref linkend="sect_TID_3521" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bb52568e-67d6-4ccc-992f-0eac7f528073">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2a18b1b5-d82c-4a8f-b9a8-ccdf71e7b484">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6c502c3-ffcb-410d-9a6f-fd04fd217d29"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9efc71e6-895e-40d9-a8d7-ed249747c6d8">$ConditionName = EV <link xl:href="http://snomed.info/id/18590009" xl:show="new">(18590009, SCT, "Cardiac Pacing")</link>
                                </para>
                                <para xml:id="para_cb5f275d-b5ac-42f5-b10c-0f45f8b90686">$ConditionValue = B<xref linkend="sect_CID_3555" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_056e7ade-8b17-444f-998b-0a649de55c51">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7db58c09-832c-489c-b59b-ebab2fe31d03">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e366c6d-4117-4157-af6a-711bdd38a3df">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_60485537-c2bd-4c5a-9388-e64b5ee6cce1">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb795047-e70a-48a7-a26c-cfc9f76da549">D<xref linkend="sect_TID_3521" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ca397743-c402-4d30-91dc-6f3913db2089">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8486b547-8bf8-4253-83da-77d875ee7172">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d8b6f36-0534-425c-8052-25943c098cff"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a452c908-baef-4c21-a125-058408663dfb">$ConditionName = EV <link xl:href="http://snomed.info/id/71388002" xl:show="new">(71388002, SCT, "Procedure")</link>
                                </para>
                                <para xml:id="para_a88e92b6-0170-4f9e-91fb-812c7b019c55">$ConditionValue = B<xref linkend="sect_CID_3405" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3521" status="3" xml:id="sect_TID_3521">
                <title>Relative Time</title>
                <para xml:id="para_d84a7e78-a381-465b-b7b0-4006199d660a">The Relative Time Template is invoked by 3520 Hemodynamic Acquisition Context Template. It specifies an applicable clinical context condition and the time of the current measurements relative to that condition.</para>
                <table frame="box" label="TID 3521" rules="all" xml:id="table_TID_3521_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_695703cd-14f0-4d21-811f-7e391c9a7491">Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7b0d0c68-faf3-4c30-9830-0fcb5542cc13">Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f49676ad-4865-4b5b-88f4-3512e8907889">$ConditionName</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b463c29-7dc8-4ed8-a49a-61376459907b">Coded term for Concept Name of condition</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_251c525c-8084-4551-85f8-7beca7d62303">$ConditionValue</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85e10b20-9c64-4385-ab56-12d0dc72fcee">Context Group for condition values</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_e6f1d1b1-1aa8-4361-841c-9e201dcf3a0a">
                                <emphasis role="bold">Non-Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_29dc16bf-a489-4e0d-977a-cdcf43719c41">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_25f49be0-d611-4933-877f-f4c7595cefef">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3521" rules="all" xml:id="table_TID_3521">
                    <caption>Relative Time</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c3be3739-faf9-4258-8996-6395fb3cafd7"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_37760b7f-a690-469c-98d2-cc1b26b26c17">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_df838acc-97f1-4830-9628-9188d0e79ed3">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_11747f51-f41d-4a81-b1ed-0633ad57c0bc">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3f5d3ffc-9567-4c2c-a8ef-9f6a0ab7424a">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a69471f3-45d3-47e8-99fd-e76de5c176d9">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7b698050-d6d6-47d4-80fc-3b294e62620e">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_92dae17a-c75f-4dfc-8add-e053c50e507d">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_49a7c7a9-44b1-4245-a2bd-a2649fd10724">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9087a204-e481-4b3f-956c-f7fe679ed9ca">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_47f30639-c144-4069-b218-dc5196a1113f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86c2d425-0c2a-41eb-8207-92e9220af3c5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bdab6e94-2683-4f4c-8b80-bc6e4f69413e">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6eed95b3-c5e0-453d-8169-b85ee2488cc5">$ConditionName</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b25a5569-3e73-42ab-94ea-cb7e1fd1c797">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_51b7284e-e62c-4505-a06d-31a61111675d">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a7bafb0-158c-4530-8e12-6d5947dbcf39"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed7ca610-6e37-4350-a8e3-e05c0296108b">$ConditionValue</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_15538814-7b5f-47bc-913f-283870a25484">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7f2a6b4-0030-487f-95d1-624dbb18b649">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_622cd5a8-9a00-4b17-a7ee-56c62bc56e3c">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3127f343-6001-4bda-b18e-8db327d661f5">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f69372b3-44e3-43df-84e5-1edc798eb686">EV <link xl:href="http://snomed.info/id/118578006" xl:show="new">(118578006, SCT, "Relative time")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_322d2c0e-153f-46cd-aebb-6850924a45eb">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7461ef8f-c51a-45ae-9487-9552ae17a483">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_899bbdbc-40a9-4c40-833a-15921919b7cf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e9f84eb-f100-4516-8c79-e12cec8563f7">B<xref linkend="sect_CID_3600" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3530" status="3" xml:id="sect_TID_3530">
                <title>Hemodynamic Acquisition Context</title>
                <para xml:id="para_f5d4fec2-b7eb-4847-a3d0-bc97928759f2">The Hemodynamic Acquisition Context Template is invoked by the various hemodynamic measurement Templates.</para>
                <table frame="box" label="TID 3530" rules="all" xml:id="table_TID_3530_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ccf75a6b-bfef-48a2-823a-4a3c85fee40a">Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_05867014-4fbb-4417-8898-f3ac7695e54e">Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_45b0e699-ce6c-46e7-b248-04405ef57360">$LocationName</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24585099-c122-4b96-a3ed-747bf907fc4d">Coded term for Concept Name of measurement location</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e9bd218-bec9-4306-8cc2-8a5f028ab7fa">$LocationValue</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e59a8a6a-b217-40fc-b543-f72d560cfceb">Context Group for appropriate anatomic locations</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_b0398bfe-6130-4ee4-86d5-8275d09c1cd7">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4692dfe3-d4dd-4143-aab3-d84358137cae">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_856fb741-af65-4ef0-8955-3bcf69c75250">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3530" rules="all" xml:id="table_TID_3530">
                    <caption>Hemodynamic Acquisition Context</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_319028df-4b00-400d-8422-039a5696c6aa"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_771774d9-323d-4bfb-bb6d-98af5e0b82ff">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_76f6e4fc-c7fd-4c7e-a22e-795a0d41d021">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d6f0809c-06ae-475a-936d-d3e349839405">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_59d2a00d-8ab9-4d0f-aef1-f55ff85d48ee">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_949b5b94-dafc-4f2c-acd7-ebb96e8f03d3">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_686fdc1b-b3dc-41b9-9cb2-a3b68490a178">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8a60b0b7-21e2-43a6-8061-0807096fff7f">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aaab961b-4cc3-45c3-bd1b-416e59eb260a">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f67bdbee-4484-4c2f-ad25-7fce1a2d5bab">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_28c69c64-ad73-4d30-a4c9-8cd634fe1b1c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_901bf3fa-9cf5-4357-9259-deb4a4b0de86">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31c0ea5a-0eb0-4907-943d-8ccb91f3ce4f">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0771d8e5-fc72-41af-9b57-88beaad8fcb3">$LocationName</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0a436424-7faf-47f1-8a7a-fe6ff7e968df">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8fbad9e3-58b7-471d-97ae-6944bf896571">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b9d5b9e-98fa-415b-911a-da23f4dfbde1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cfce2904-51d1-408e-bdc3-0956d4dcd905">$LocationValue</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d6973b9-9aa9-4977-b33a-6a851983c94f">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3387705b-fbb5-425e-b8d0-bb53535f3689">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7cd899af-67d3-4657-87c0-db9efdc6da49">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_247908d7-3b7c-4add-9658-9a00e7b79e8d">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_28149c03-d80b-47e3-b2f5-f541144dd2a9">EV <link xl:href="http://snomed.info/id/106233006" xl:show="new">(106233006, SCT, "Topographical modifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_41fb4f24-c75e-4b5b-ae6c-59189addc141">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_27faeb5a-0722-407f-8aee-c21bbc19d4bb">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd34accf-98d2-4980-b434-897948ee3ec1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17520f7d-53df-4457-8500-21d235ebfd07">B<xref linkend="sect_CID_3019" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_493d8c95-36cf-4fa4-a577-f197db444f59">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_623b4e32-5cbb-48ea-9722-db016a779746"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e227e76b-1148-49b7-808d-c1f5f8000c8a">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9fff967e-1c65-4a31-a614-7b11caf564b6">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dad38b9a-a40c-4ea2-b4d0-63c84535bd67">EV <link xl:href="http://snomed.info/id/370129005" xl:show="new">(370129005, SCT, "Measurement Method")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ebed7fa7-7359-4ace-b01f-ce419fbeacb7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ebff0e4-c5ea-437a-b1fe-a22477a3fe83">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c072624b-b56b-4f85-8393-7754dbc4109b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea4d8a31-6568-4078-83dd-1cdbadc622ac">B<xref linkend="sect_CID_3241" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ed23e72-49d1-48a1-8b4d-b74a4c232a1d">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee939f1a-43a2-42d0-a9bb-82db0f335346"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_53d11fe6-84f8-4316-b044-1f8810aa753a">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f83fc439-d0c3-44da-bcf1-a1d2f1b7e47c">WAVEFORM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0846d800-175b-400d-a42c-8e38dbfa816c">DT <link linkend="DCM_121112" xrefstyle="select: nopage">(121112, DCM, "Source of Measurement")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3cc76ae0-1852-4b96-b073-140f0ceafbb1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e2f7319a-c584-47a6-8c48-b31c0de1f89e">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c02f953-3ef4-45f5-b3bf-e3d6e28c353b">XOR Row 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0163ae1e-f3de-46f2-876e-275bd4c11c64"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e15d99b5-fb5d-4c63-b91e-a564bee00520">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ba355a6-bef6-4079-8703-bc129a9e157a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d9ded62-d0bf-4d79-9923-6c03f673e869">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e982aed-fc42-4ef7-bafb-c65cb2146468">TCOORD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ddc5d1a9-7c4e-4efd-81f2-90fd0658e97f">DT <link linkend="DCM_121112" xrefstyle="select: nopage">(121112, DCM, "Source of Measurement")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d9104861-10e1-45b4-a4f6-7eefff1247bf">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5bd44ef8-b804-45cf-ace2-1a07b33fdc5f">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9cd756e4-0f72-40b7-802c-4d5f87cceda7">XOR Row 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63a6516f-9f6e-4d95-a603-8727a2351917"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17673f63-83c8-4dc8-b6a8-c500ce8d6fe1">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e83e4fa-8e97-45b1-ba8a-e73a62eea9f0">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03a6c9c8-dc60-4531-bac4-bc6c92b1ba3d">SELECTED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8fdc94e-09dc-44ef-9cab-baf2f9afad14">WAVEFORM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_07760b0e-bbc6-4db5-9690-6302666568a0"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_08d3f0cc-d645-4ba9-a118-65b9f170f7a8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_050d1159-b31b-466a-baa1-7d57cd1f8a1f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5f87768-1205-41f2-bbde-3a98eb932c74"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2655d417-7b94-4435-9aab-cbf6ecf95fb4"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3550" status="3" xml:id="sect_TID_3550">
                <title>Pressure Waveform Measurements</title>
                <para xml:id="para_0e11cd48-73fb-4149-a56c-c3f520b6bdbe">The Pressure Waveform Measurements Template is invoked by the various hemodynamic measurement Templates for recording general measurements made in conjunction with the specific required measurements for that anatomic location.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ac492b7e-2ca0-4544-81e7-4b9c62f769bb">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_16056d7f-1b40-4096-ab78-7c633a0e62ac">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_8a87a69a-3a46-4642-905f-65846b7ac7ef">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3550" rules="all" xml:id="table_TID_3550">
                    <caption>Pressure Waveform Measurements</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f6d1f90c-bf41-4a85-a8c3-ed4dae2cd09b"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_518748b7-bed9-4200-8244-f36eadcd5a7f">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_74d7928b-ddf1-49ce-86fc-445c9677bff6">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c27d85f7-ca77-4efc-a7f0-0c8aeeffdf0c">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bf764ebd-e83e-46cc-836d-17d13234c8ec">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_22ded723-62e9-488e-aa9c-9cde8bebcc1a">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_706e8b97-e448-4fb3-bba4-5dd917e1d789">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_54310288-01a8-47b0-9d99-5ad75d156a47">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_af2d2528-0f43-4e16-97a9-0def78fe2f35">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_789d957c-dba9-4d8d-854e-e8a2d9093fbd">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c64b5c00-7d67-4734-b908-7b882cba7777"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d73e596b-3fae-44b1-97d0-355066a210e4">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9935449f-0af4-47c7-bd0d-2cf18b46d08d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5788c177-528a-4a5a-a83a-af5cc718c860">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0f8ac3f0-e35b-4afa-b260-54ebff7fee6c">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a313571b-a825-48e3-8a26-ea11c14d3325">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9908881-9931-404b-afb6-54f5d2de1918"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29b21ae2-8095-4c9b-8b2c-6d3bb58e7b24">$Measurement = D<xref linkend="sect_CID_3611" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_c8f99b28-4065-4f7b-8a5e-11da6cf2a26c">$Units = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d2c43e68-0f0c-4657-9d95-8b5b8bb20953">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e847fa2b-bdde-4983-85d9-1ebd3a9d6321"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5382b9a-80d1-46b8-9f1b-b1e6784d9ec1">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7fdda82e-8c9a-43d3-9dbe-7140a3de7fad">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_19c8a7b0-52b8-48ff-ae9a-c4ba491a514c">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0f78a1ad-fab8-43f0-9c64-307f0ce14086">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_364fd6d6-2610-4be0-8ab8-3b97dabf8545">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09ca317e-ec5c-4329-8580-c00b19f30cc0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a6eb2b8-6533-41c7-8efa-6efb4cfcd11d">$Measurement = D<xref linkend="sect_CID_3612" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_f4e4273d-0fc5-4f19-a8ae-5e30f62ef7b8">$Units = EV (mm/s, UCUM, "mm/s")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_605ee61d-d193-4fd4-9b3b-c924f535fef9">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09ab6d18-61f4-432d-9e9c-f052b7541f2c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c2f6f221-bec7-4651-ab91-2032926a8106">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7bb1ae40-ed44-413a-bdac-bdd07598ba0c">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e870644-9c57-47c1-8b92-f7aae285f185">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9c62505c-686e-4ebe-915e-3f50ec0298b0">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_818677b8-0753-43cd-bf7c-67d483f518b9">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9088484e-e56a-4f94-90c0-97c2920974a5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b479977c-b81d-45cf-88d1-909852118a15">$Measurement = D<xref linkend="sect_CID_3613" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_54c954f9-780e-493a-b124-812c071e0279">$Units = DT (ms, UCUM, "ms")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8f8f59d-5b39-40cf-834d-e7bbd69f8853">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8fdca101-147f-4f23-a0d9-d5bdf8b3e5f4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_910e2738-111c-4ca4-a321-4656c5e61775">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0bf21dff-4ea4-45ac-a6d0-8ee5b17a71a7">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dbcf8210-fdf7-4d5c-8352-9940efc42c67">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_65499c69-feac-4505-8655-1920a1245b89">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_02642f4a-8d64-4aa2-9e9f-84c7defaa0e3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c3412753-6edf-439c-88a1-f39e50276e3b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b9d167ec-2e42-4e17-9a71-4d2706bf60c3">$Measurement = EV <link xl:href="http://snomed.info/id/82799009" xl:show="new">(82799009, SCT, "Cardiac Output")</link>
                                </para>
                                <para xml:id="para_e35000a1-bc51-4c84-b96f-85835f0634f1">$Units = EV (l/min, UCUM, "l/min")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5c6f9e5-5c0e-414e-b9c1-e4394856b271">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a450e1d8-6abe-4924-b680-c6ea208fa089"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9928bdbc-8722-424f-9264-cabb7cf8bf34">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6697c34e-706e-449d-b25f-e51c979abc2f">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_56dd3c21-3404-4999-a9e0-b095040124af">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_48350683-0967-4f2a-aee6-7571fff6c871">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d13ad8d9-26be-47bc-96f7-b19d6fc816cf">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d5618f4-e1ff-45b5-b0a2-e3842cf59c02"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_71acfb1a-66aa-47a0-98d4-c385fb22c079">$Measurement = EV <link xl:href="http://snomed.info/id/90096001" xl:show="new">(90096001, SCT, "Stroke Volume")</link>
                                </para>
                                <para xml:id="para_8758cb2e-0ad6-4222-976d-803cd31f2399">$Units = DT (ml, UCUM, "ml")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f5cc9b0-0634-44eb-b635-d5913bbfe146">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_829a8bad-3cfd-4923-8354-7c176011ac2c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_45f3523f-e4b5-4ff1-a357-855e79986478">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fddcd70a-f381-4e8a-add5-33122dc2d365">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e82fc8f0-3ebd-4284-ac6c-993a878a6416">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d1027c5b-e9ae-441e-92b0-dfaa78364fdb">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f6cfca9e-40f6-40d5-9407-3a6d22f084e9">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62e5316e-74b1-4e4b-b7c3-111099c18938"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f313eb5-1d6b-4524-a164-d3a0aa1f4874">$Measurement = EV <link xl:href="http://loinc.org/10230-1/" xl:show="new">(10230-1, LN, "LV Ejection Fraction")</link>
                                </para>
                                <para xml:id="para_fdba38db-fd26-4f78-ba77-87132b270c7c">$Units = EV (%, UCUM, "%")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c6ee5ebf-9caf-40a4-ad07-f1cc9656c398">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7c3a209-2e45-4c0b-bf27-9fe49f602197"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6787ecd9-4ad1-4cfa-b238-c7455b9c35e0">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_814c4766-90cf-4f95-a96c-c0ad56758065">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6832b342-8a8b-4937-be31-2a99a934b7fc">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_774bb3fc-182e-491d-a4d3-bef25e419cf0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b0ae3f7d-8abe-4400-b8ed-0de3e826f8e4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9eb12f3d-9e75-4b5d-be4a-926c94393e7e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0532bbad-be79-47e7-89c1-3bb0f74f2aba">$Measurement = EV <link xl:href="http://loinc.org/8867-4/" xl:show="new">(8867-4, LN, "Heart rate")</link>
                                </para>
                                <para xml:id="para_479eefc2-b1c5-407e-8e1f-9931ebcac0ae">$Units = DT ({H.B.}/min, UCUM, "BPM")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98dedf4d-e804-48a4-9fc0-5a9d58acb566">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75dcdeb4-bbfa-44c2-84c2-9086a6084268"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc500f03-bd33-4d0a-86b3-e42b1e43db5c">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0168fc5b-a8df-43be-ba6e-6b121de6394a">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba2696e6-75e9-433b-b9f6-8eafec4f9be5">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_787b4617-f436-4724-9f65-25e964bf7552">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9d685de0-719d-4ab8-8c71-8dc6fe72faa8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_44a5128d-3d91-4a62-8bb8-2fd0a8444c09"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a2b55cd-8ce2-4265-bdce-16469814ff14">$Measurement = EV <link xl:href="http://snomed.info/id/86290005" xl:show="new">(86290005, SCT, "Respiration rate")</link>
                                </para>
                                <para xml:id="para_f30e14b7-fd76-4953-b7c0-645adc39112f">$Units = DT (/min, UCUM, "breaths/min")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f39a9bd5-1035-4091-a3bc-bd862f3a26f5">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dcbda682-0a41-4e38-8cb6-28cb7924959a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3638817-c5a3-4726-ae86-9c11db68d644">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb572e32-7c2a-4a7e-890a-65d9ab791921">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba89b2e9-880a-4ee0-a3a6-e621df40b5ec">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e36a95a5-2b79-40cf-99e4-35faeb3c88c1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9ac72855-2973-4d5d-9a2b-fe8f9c2a9041">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8ae4c0c-4e97-446d-aef1-d5cd66ce4c27"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d4e4b08e-f273-434e-b6e5-9797b396cfc0">$Measurement = EV <link linkend="DCM_109025" xrefstyle="select: nopage">(109025, DCM, "Max dp/dt")</link>
                                </para>
                                <para xml:id="para_2df11949-e7de-4460-9346-a3e648f94de9">$Units = DT (mm[Hg]/s, UCUM, "mmHg/s")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cfd0eff7-a2aa-4125-abcf-97ad88fb5d18">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2116f603-f98d-4911-b43f-3b3f5c34152a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4fd39a3e-e766-4be8-a58a-a9a17afb80a6">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da912484-6c48-47d3-be7f-c0416ad18493">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a80240cc-837e-4f2a-9b6a-41381dc17661">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b45c7f9b-f6bf-4a75-a1a1-d7879db1bd8b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2b109822-4688-4bbb-a5c3-916090446611">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7cbf8ffb-1050-4d34-86fc-5d165f5b5ddd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7db73b79-e805-4c9e-9d07-f4c4d5089367">$Measurement = EV <link linkend="DCM_109026" xrefstyle="select: nopage">(109026, DCM, "Max neg dp/dt")</link>
                                </para>
                                <para xml:id="para_c1471cf2-bb6a-4cee-900f-4fd823b82796">$Units = DT (mm[Hg]/s, UCUM, "mmHg/s")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81b70e8d-84e9-4f0d-a1e3-dc0313124cc9">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9046fa9-97e1-477f-b344-b6c0a0be3e3d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d200b363-1a77-4961-8f18-ccd5dccb80e2">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5732dfa-6da8-4aa1-9a00-76c666cf9852">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d44cefb7-3df6-4b54-a333-d4cdadee8785">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c7c53181-68ed-4123-9fc5-3a3f09508b00">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0fe7a41c-f8f1-45c3-b73e-2c54c1730558">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d90dd3d7-4fd6-4646-87b5-2418685b5c00"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb345e11-0cc1-4701-a4bc-2066fdecc2c5">$Measurement = EV <link linkend="DCM_122190" xrefstyle="select: nopage">(122190, DCM, "Max dp/dt/P")</link>
                                </para>
                                <para xml:id="para_542a6600-5999-4191-91e5-c8f00c5fc8e0">$Units = DT (/s, UCUM, "/s")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29af0750-009c-4a13-a605-9bc57535659c">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc6591ba-301d-49d9-b02e-ef8ed75639f1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7a2cba4b-f335-427b-b490-6d5aa1676f8b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31ecc9e0-460b-44d4-89fb-6f263e64eb94">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3d69915-169c-4a16-9111-c4f6409d1596">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4556c06d-b2b9-4867-9d4e-38370e06f777">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c469e386-4f0f-4230-b2f2-3bd13d85a17a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a132755e-45c9-4810-8b33-1a5bbc5f9273"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2a0bcfe-5a87-4153-93f2-b8b641260b2f">$Measurement = EV <link linkend="DCM_122192" xrefstyle="select: nopage">(122192, DCM, "Indicator appearance time")</link>
                                </para>
                                <para xml:id="para_2732d47b-79d1-4e27-85e4-36ffd3c03ae4">$Units = DT (s, UCUM, "s")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_242b4f75-999f-40ec-a737-44098e1c7270">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75f99464-bb45-4acc-b383-d4aa8a3030ff"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_324591e3-e2c8-4792-9477-f3ab8f3b8739">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f13798f-3da6-4591-a54d-6b5207d11e77">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9001ad5-ba45-48f8-beb5-d8fbba6c5a29">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_68b49b5b-7631-428f-94d3-9a637dc8b0b2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6646a816-bd42-418a-a941-e583e42dd85a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87e6c2e2-d4f4-4fb0-bddb-f547ca7a8586"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25c019c3-f6ed-4f62-ad34-f632aed5ba85">$Measurement = EV <link linkend="DCM_122193" xrefstyle="select: nopage">(122193, DCM, "Maximum pressure acceleration")</link>
                                </para>
                                <para xml:id="para_cae8be90-0d0f-496b-8e71-cd39b8002dec">$Units = DT (mm[Hg]/s2, UCUM, "mmHg/s/s")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f51616dc-4965-4da4-a2b1-acb33bc63731">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a65147d-7e91-420e-a15f-08ad05b29e3f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a1005dd5-0f5e-4396-a2f6-5ea64e21449b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_68a6aaff-7f70-48b2-a85a-17058f9f50fc">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b05c5935-9842-496d-8c4b-4fa3e488eeb6">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7a852b00-252f-4d3c-bdee-94b109706ea4">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c942d30-220d-4eee-9e02-c552dc509c87">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_12eeccfd-8f2f-4043-bec6-02ef2ebd0a3c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3c91950-71a9-405f-a01e-63f8ffa92bb7">$Measurement = D<xref linkend="sect_CID_3617" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_d2ab126a-f5e4-4dd2-bf0f-3f3400b169b8">$Units = DT (ml/min, UCUM, "ml/min")</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3560" status="3" xml:id="sect_TID_3560">
                <title>Derived Hemodynamic Measurements</title>
                <para xml:id="para_967d060b-85e8-4d97-b48c-3797b6fe2d73">The Derived Hemodynamic Measurements Template consists of a CONTAINER containing measurements derived from one or more other measurements. These measurements are associated with a particular procedure phase, but not necessarily with a particular anatomic location.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_2672d5af-97ab-4517-a7d5-50829fe1ae5e">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_fad756c5-386e-4da8-ae3d-c2ff75e02bfd">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_55403a95-b33d-41d4-ab0d-86306949bac1">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3560" rules="all" xml:id="table_TID_3560">
                    <caption>Derived Hemodynamic Measurements</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5253dc3a-af95-4fa4-b92a-133533f079e4"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_270a28e1-9d90-4ace-8327-ef86b841062b">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_50bcb833-cda9-4d01-8f14-5a31f8524f11">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f56ff6de-dc60-4591-8c12-91f6f85dabf0">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1e3b900d-a324-4232-89c2-7105121087cc">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4eff614b-7b00-409e-9c48-7731d07f0ca4">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5722ffa7-12a5-4727-9353-2732d1fc4399">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9bb82e2f-a8c6-45ee-87ad-5d784e515b98">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e8bd61b3-9d34-4271-9a7a-73a3bfff392a">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_33582aba-ad73-46cf-a44b-dfb6b14c2728">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_590930b2-cd01-4b48-9781-787d7a61d450"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc65fc38-78e1-4ae1-af91-e7dbc8825265"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_410aa3d9-8c68-4eae-a7d4-051af6216df9">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7032c13-4a9f-41aa-a1c6-a725750d7146">EV <link linkend="DCM_122126" xrefstyle="select: nopage">(122126, DCM, "Derived Hemodynamic Measurements")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_77f07f8d-05d7-4071-80ec-9904ca2435a0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_08814267-c204-4e23-a15f-dad1f0fe6673">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d530ec4d-9d07-4d12-85ca-1b80f329bb5a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_401fc715-7807-4154-bd13-abfc1d4b6952"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f793b50-c774-43e4-ab5a-3b1514029544">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_427e3d30-2d73-4da4-9da8-ab18dde92e12">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0002e7e-cca2-4ba5-af4b-0a9db905652f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d6025d2-08c4-4019-8dea-b153c0bb2890">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e38546b-4a77-4720-bec8-0492b058b233">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_396f197a-a90b-4121-afba-c32bf823b5fc">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_47d53a79-675f-4abd-be21-68f35743f7b0">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7c51e54-ace3-4c3e-9b54-71bbe6c8bcb0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_56a02b53-cf26-4ae1-8647-b90fb22eb5ee">$Measurement = D<xref linkend="sect_CID_3614" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_89c3b495-89f2-44cb-9df9-86b6255b9787">$Units = EV (cm2, UCUM, "cm2")</para>
                                <para xml:id="para_622acc51-8554-4c66-b3a7-ea980fde26ac">$Equation = DT <link linkend="DCM_122262" xrefstyle="select: nopage">(122262, DCM, "Area = Flow / 44.5 * sqrt(Gradient[mmHg])")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_94f89f6a-6ca7-4b40-8307-60d35899326d">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a69059c0-a826-4620-b5b2-4a9ac262d3a2">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3392351-f086-41e0-b409-3b07c0273910">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d200a24e-0e72-48fd-8d2d-1f872258165c">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21e2b6a7-bf01-48e5-9c5b-ce1911e1693e">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f034a492-a1eb-4124-a440-61e8f4aa4de4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_37c8a69f-ea8f-4a0a-8fd3-f7a206e1dd3c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83276607-e2c2-479e-ad46-8333967a6b29"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cced0d6a-d209-47ca-929e-58307264a31b">$Measurement = EV <link xl:href="http://snomed.info/id/251012002" xl:show="new">(251012002, SCT, "Mitral Valve Area")</link>
                                </para>
                                <para xml:id="para_84488bd6-e9b1-4701-bd79-505c6c92b45e">$Units = EV (cm2, UCUM, "cm2")</para>
                                <para xml:id="para_23e4995e-3799-4585-8174-ffefa886d686">$Equation = DT <link linkend="DCM_122263" xrefstyle="select: nopage">(122263, DCM, "MVA = Flow / 38.0 * sqrt(Gradient[mmHg])")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd7491c8-ced4-43f5-b700-3c88b53dedbc">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a1d96752-8390-457e-94a9-088f5d33d24a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a0e470f-e5a4-4f86-a567-75cec3475044">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_681e44f0-5134-48e6-91d3-fbf2f34cb8c7">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c723251-318e-4ff8-817d-cfdbddfc3c21">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8e7057ed-7b6a-4660-810a-46681a35044e">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_99439d8b-173d-4ad4-99b9-8d864d726aee">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21446f99-440a-4926-b2a3-9a1b529f3294"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7d3e05a-42ca-4c38-aa3d-9c914f771214">$Measurement = D<xref linkend="sect_CID_3615" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_29da0280-689a-4eb1-80de-5376c929222f">$ModType = EV <link linkend="DCM_121425" xrefstyle="select: nopage">(121425, DCM, "Index")</link>
                                </para>
                                <para xml:id="para_dbeb4cd8-bc04-4828-9839-465d343dd725">$ModValue = EV <link xl:href="http://loinc.org/8277-6/" xl:show="new">(8277-6, LN, "Body Surface Area")</link>
                                </para>
                                <para xml:id="para_81c2e78b-242b-4fa3-a8dd-b1bf1bc6f1e8">$Units = DT (cm2/m2, UCUM, "cm2/m2")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e27933a-63d8-49ea-bd5e-a5096095abc2">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd969cd8-da46-484f-8374-051b2a10bae7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00339e3a-0977-40ad-a2bb-ee499b5fd57c">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_66c79387-ada6-4c16-a6bb-28bffbacb95a">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_873d0925-770f-47fb-9003-c0cf437ee4e2">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_975abf2c-5b61-477c-b1ee-8328f2b20991">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_82f3179e-5053-4b96-bbec-9843fbe56227">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6a931c9-26c3-4e29-9d8c-9d24b62c129e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ecb9c820-29db-4af4-81a2-3fbbbffb2da8">$Measurement = D<xref linkend="sect_CID_3616" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_1fd828b2-ec3f-4957-8b00-ab7dc80f5d86">$Units = DT (s/min, UCUM, "s/min")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48a59355-dc86-437d-8269-1d0d3cb0543a">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b8b0b44b-caca-4dfd-90e8-9836630eee1d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5bf2f9d-ce2e-41bb-89e0-1d75edad3f8d">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d455dc7-aa32-40f9-96b4-022b0607768d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e581f755-d57f-4968-ba92-e10eac3351ea">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1e1c8d11-776e-48a6-8491-67e8374b40e9">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_95907b10-dee8-4894-a911-caa455f6f155">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4f266bc-87c3-40dd-bfbb-a272e324a8d4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1f11f753-1a0e-4ce2-b8d4-dc304c375be6">$Measurement = D<xref linkend="sect_CID_3617" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_9d7fa786-4c9d-4324-8c23-5752d5024260">$Units = DT (ml/s, UCUM, "ml/s")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9bea82d4-47f5-4e51-b33f-6104154530b9">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d9d290b-9c9d-4e81-a1bb-af04490d306b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_44f35946-fd91-4c5d-baeb-4beb2a70e4d4">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_870fcbf8-fb26-4e7f-ae33-bd3da0dfc4b0">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a249aa7-4f1b-49aa-b814-b927901b8102">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc4fd083-017a-4e31-86ee-6217091f7f30">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6424d986-640b-41df-b6ad-c888521478c4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_312b8f06-95aa-451f-b1a0-7ae2a83b70e7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7dea1a58-f691-4d6f-a60b-7f44b6165bbc">$Measurement = EV <link xl:href="http://snomed.info/id/54993008" xl:show="new">(54993008, SCT, "Cardiac Index")</link>
                                </para>
                                <para xml:id="para_7282d261-c6ee-421a-b022-8efb07e4aa26">$Units = DT (l/min/m2, UCUM, "l/min/m2")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc8edccb-686d-45d3-a715-8be7fd355f9a">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05b08f74-9fb7-429e-a735-1f3bf420d4b5">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9797e432-c9a8-4494-8d16-0ed87b94e3b1">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65c74cbc-904a-44d9-990a-60d46312d22b">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88529729-c6f3-4115-bb38-a4ef15c267d0">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c4f14b85-dba1-458b-9eef-23d78749ca4e">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d9887b98-1bb9-434e-8306-d15c6af2ed0f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_90b955fd-7964-4801-b481-cca75495cf44"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f404f29-b7ae-4e19-be0c-26aa202398b1">$Measurement = D<xref linkend="sect_CID_3529" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_b3b798b9-c661-4a90-a110-99ea73be850c">$Units = DT (ml/dl, UCUM, "ml/dl")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8996a302-dd6a-4efd-bb83-c12b969f5f62">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b01a15e1-5d8f-4c10-b608-1d91ce2b5651">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3bca15da-a9d0-4123-94e9-c82c4f70d6a1">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_660cf951-1c12-41e6-a572-1d9f21a9f8dc">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e54843a0-c63e-477f-a5fb-30f004e89664">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b896b8ba-47b0-43c5-b03c-d7c1a9d0cb4d">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c322aa88-8fa6-4e8f-a358-68f58cf71241">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_514f4ce7-728e-4553-bd5d-f4941477a1b5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e514809-602e-4edf-8642-cd2db7057ae8">$Measurement = D<xref linkend="sect_CID_3618" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_88163b92-91f1-44f7-b5d7-237ec5d651f8">$Units = DT (l/min, UCUM, "l/min")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17b26605-08f7-4a28-8960-25c9f8e6da00">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_201ebca0-3c17-4ea1-a3af-1dadc899cf77">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b4c4d57-36fa-4f49-bf6f-e60aca00802f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86562529-d10f-41e9-b605-3c1175648e72">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0089baaf-ccd8-438c-b097-f5f2becf2457">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f7e29684-996a-4171-a99e-1d73b3515213">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a8a1e691-0dc9-4433-855c-4eb3417e1c00">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c2a57e17-4159-417f-96f8-ae744760499a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9df985bc-a3a4-4fbf-a547-1776ababd0a5">$Measurement = EV <link xl:href="http://loinc.org/8736-1/" xl:show="new">(8736-1, LN, "FICK Cardiac Output")</link>
                                </para>
                                <para xml:id="para_c041b05e-901d-42ce-8e8c-60fc317cf2d6">$Units = DT (l/min, UCUM, "l/min")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_95e1ddec-14ad-4662-a84d-ea76e2798e59">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_32eeb606-ee6d-4e5c-8afa-ccd4b911f19c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de2e13f1-e0ed-44d5-8487-b61e3a5c00a6">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d22b1934-98fa-45ce-8d06-88620a3a407a">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c57edab-695e-4bee-b42f-7a90a32149cb">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_64d166f9-93c6-4691-9ff8-9be75c9b7b4b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_312ec6a2-53fd-4c2b-884d-52ce54364d38">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_074c1eab-a250-4774-819a-2cc7267b7ce0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5315debd-66b4-41ad-8b4f-a56d3ecf61f1">$Measurement = EV <link xl:href="http://loinc.org/8750-2/" xl:show="new">(8750-2, LN, "FICK Cardiac Index")</link>
                                </para>
                                <para xml:id="para_fb2922b4-3148-48ab-b613-f0c85f81a017">$Units = DT (l/min/m2, UCUM, "l/min/m2")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d68347f-5e01-4cef-b273-303f1b0ffdc8">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8758092a-6c54-4ca8-92c5-051ef128c02a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91e2007a-b500-4a37-830b-735e2ac347ab">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4031a5ab-d519-4721-96cf-497eef58bee2">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4119a0e-723a-42f1-9dbc-6ff221a524d7">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b1c2ab5-b11b-4451-9acf-ca656becffb7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b4b42dac-eef0-41d3-bb54-1ce36cabba56">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bebe94f3-de02-4170-8135-dae5840f3761"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03506a05-76f8-403f-bd69-90d09000c769">$Measurement = EV <link linkend="DCM_122229" xrefstyle="select: nopage">(122229, DCM, "Arteriovenous difference")</link>
                                </para>
                                <para xml:id="para_ce7f4664-6ffd-4587-83e7-6e1331e5d4a8">$Units = DT (ml/dl, UCUM, "ml/dl")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1857befa-215d-4b7d-af5b-70bee04c59be">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4313537e-bbf9-4598-a45b-72763ab9549e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_996ef8fc-8a3e-4f8e-941c-0e487effd145">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a505f06a-9031-4638-9777-b74105663a6b">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4a404ac-af0d-4b13-8a68-f27aa453d51f">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5077ea04-5198-4e2f-b3b0-b770caf60f98">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_98ab42fa-64c6-4216-ae62-1e9719c9f0f2">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_990fb030-5e25-4a7a-a402-4e52255ae2bd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5eae17ca-d634-4242-970f-3b4222616731">$Measurement = B<xref linkend="sect_CID_3620" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_4213388b-677a-4dcb-9e7d-296987030e2a">$Units = DT ({ratio}, UCUM, "ratio")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d8e20c2-250a-429c-9c6c-d5e061e00032">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_89b7b0a4-8c55-488b-84a3-68933c3248b7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_226a5d77-a5e7-4215-8640-feaaaafce733">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5db44f53-cd37-465e-800e-d3c8446df25a">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d22c1f02-d418-4c9c-bc4f-265c25ae4c79">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b16afc08-7938-4e1a-9db4-0ee85dc69098">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_72028f99-3f96-4339-b7b7-a5e37ff3cdf1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_578fa184-41e6-4dd4-a6da-1ee537137130"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ceca9b39-345a-48e9-9553-3395d41ee0d4">$Measurement = EV <link linkend="DCM_122237" xrefstyle="select: nopage">(122237, DCM, "Corrected Sinus Node Recovery Time")</link>
                                </para>
                                <para xml:id="para_8dc2ba39-c3eb-4eb2-a49d-04ef90c62144">$Units = DT (ms, UCUM, "ms")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c79a272-667c-429f-81dd-88a8913ed506">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e85b5327-79c4-49af-85e2-f670999c769f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c9f2a07c-3aa5-411d-9721-096eca372e65">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3648aca7-a452-4cc4-8fdc-f7a08f9534d6">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_15583168-929e-4cfe-870a-4baf953e050e">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ee2eb86f-bb29-44d7-9832-03491b28ead3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3c6116e0-71ea-4381-91c7-aac53107fdd8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5d78010-a7a1-40da-9f52-a4fad375b6a7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cfa1b964-5597-4d09-86c4-d1d80ad906b6">$Measurement = EV <link xl:href="http://loinc.org/8861-7/" xl:show="new">(8861-7, LN, "Left Ventricular Stroke Work")</link>
                                </para>
                                <para xml:id="para_c34d0452-9c04-44ef-8c92-89e159f182c5">$Units = DT (gf.m, UCUM, "gf.m")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9cd23408-a954-4c5e-800d-d24047df37f6">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a0c5fc3-7310-4aed-97b3-20bae31de39c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a302714-1942-4377-8ce8-3855e55e0cc9">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cda7e252-2906-441b-bd37-8af9e19ee4bc">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1250d284-4e67-4310-92e3-73e04cf27fb5">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_757bc619-9955-4531-85e5-15b63bf20834">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_013c9adf-6883-471f-b070-1759e67a26de">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4da670e-b01d-4858-aef2-0d7be46f5c8f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bdb2bf81-43a5-401e-baf1-5e1344904e70">$Measurement = EV <link xl:href="http://loinc.org/8862-5/" xl:show="new">(8862-5, LN, "Right Ventricular Stroke Work")</link>
                                </para>
                                <para xml:id="para_b856de35-aebc-4676-a032-ba6f84842939">$Units = DT (gf.m, UCUM, "gf.m")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3264be7-061d-4b98-aea6-5cacbc0ef792">17</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eac2c592-05a7-4d15-9777-5c3b8236dea7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1692663b-fdc8-438a-b254-8230d095ab40">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31d44b6d-2571-453a-8e81-b510bab9b0c9">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1615b58-b78e-4815-bc5f-e248a872e3a4">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d37cf2ad-7e4e-4eed-9234-defefc43fdb0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7bc51cca-acb1-4930-9bca-14e083fb15f1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_253bfd1a-76a8-4f7b-b310-041082e9fc40"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30b3b3e1-2258-412a-b167-b5f09a216e38">$Measurement = EV <link xl:href="http://loinc.org/8863-3/" xl:show="new">(8863-3, LN, "Left Ventricular Stroke Work Index")</link>
                                </para>
                                <para xml:id="para_3c53fe9b-40f5-460e-803b-f731f7609abc">$Units = DT (gf.m/m2, UCUM, "gf.m/m2")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4d8ddfa-180e-4336-adcd-f5b3789d2f23">18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf442eab-961b-4671-9011-e8405178f18d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5fff3da9-7057-46bf-8ab3-3ceed71cd2c1">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b673272d-8033-47b0-9314-dfd81f24c5f2">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4f85c47-9249-4ca5-b4e7-a5e3189ce9fd">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a7aa9f4e-bc70-4a57-8c84-3d45d45a04a1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b5586819-92f9-41de-910a-ab102a3ca42b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2bf79131-ba49-4491-8369-8911d956ebf0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f67853be-5a14-44b2-8b5b-136fa89b874f">$Measurement = EV <link xl:href="http://loinc.org/8864-1/" xl:show="new">(8864-1, LN, "Right Ventricular Stroke Work Index")</link>
                                </para>
                                <para xml:id="para_eb56dae0-8e8d-497b-b008-4739bbde45bb">$Units = DT (gf.m/m2, UCUM, "gf.m/m2")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b30c1488-d118-48c9-a6ec-b54d0a090fdc">19</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a35cd6f2-d439-4950-ad93-44f69aca0fa9">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5872bd60-3abe-4fd9-a883-087dfaea5a03">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46b89420-a2d0-4c26-86fb-c42b994a5a47">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d7868396-76ad-4281-a4da-45ccd0d331b5">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3537d545-a084-4b23-b29f-8fa5116afeee">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_97bbdd4e-5714-4737-84ae-ba8445766184">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0bf4e613-2718-49b7-99df-12b73634b13c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ec96534-de5c-4003-8d3e-205e64e94826">$Measurement = EV <link linkend="DCM_122238" xrefstyle="select: nopage">(122238, DCM, "Max volume normalized to 50mmHg pulse pressure")</link>
                                </para>
                                <para xml:id="para_13a78496-3e44-4fe4-af8f-f62bb2f4eca5">$Units = DT (ml, UCUM, "ml")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39f9c95d-521d-405e-a9b3-ac3eb7ea6deb">20</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a9edf41-93c7-4bfc-899c-c5e6f18e6a1c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_228532cd-8743-4072-9710-8f0f5ac5cb1d">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5478877-9291-43e0-becd-77f7b3b03670">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1045a2cb-efa2-4aab-8475-16f720bf55c3">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e8425d18-eafc-41c4-8a34-bd8153de1bb8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_86010ce2-2a01-4b0d-8ee2-774687ed94bd">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f64d084-712b-459a-9351-da24bd247238"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_226fe5a4-9970-40d6-b9ec-0c7f6b456229">$Measurement = EV <link linkend="DCM_122239" xrefstyle="select: nopage">(122239, DCM, "Oxygen Consumption")</link>
                                </para>
                                <para xml:id="para_de8442c4-fa56-4f2c-9574-fb807fdfe0b2">$Units = DT (ml/min, UCUM, "ml/min")</para>
                                <para xml:id="para_de631987-550e-49ec-a825-7a2f087f95bb">$Equation = B<xref linkend="sect_CID_3664" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b368cd6-87f4-4217-9505-c247b894eeed">21</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe18ce54-3ad0-4000-9ac8-f9258d941500">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16f06809-a12c-43d3-a506-923150bc6d37">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21121088-3e36-4993-8af7-e81f1ada5a69">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7194ff3d-1d7b-4afc-993e-a77970195b5c">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69da24d2-f005-4168-87e2-0dead187795e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_100df6b7-c77d-49ed-945a-396638b44112">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02986f04-184a-4584-9d5a-89d018f6465f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_002f2b3e-12f5-444a-b7f7-284707767d8c">$Measurement = EV <link xl:href="http://loinc.org/19217-9/" xl:show="new">(19217-9, LN, "Oxygen partial pressure at 50% saturation (P50)")</link>
                                </para>
                                <para xml:id="para_a3423856-aaf9-4539-bced-83d2a4f363b8">$Units = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_8880a356-f8d3-471f-947e-b16c2b721ee9">$Equation = B<xref linkend="sect_CID_3666" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0fd088f5-881f-43ee-9027-4d504dcbc828">22</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4608d811-463b-4840-816d-ba74b0306282">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c42e2fe-f45a-49de-86c5-717051378bc1">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_45edb11b-1bca-4eb8-908b-a7a3f7dfd291">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6bae6a48-9858-4281-a7eb-856b9ef13060">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_919fee22-92de-49cb-abc4-d5225cbfbe77">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7438cbc0-1ace-48a3-b4f5-59b60ba64dcf">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e7b41c5-dd08-47f4-b571-871ddf5171b3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6447ec1-adc5-484c-8cc8-018964603304">$Measurement = EV <link xl:href="http://loinc.org/11556-8/" xl:show="new">(11556-8, LN, "Blood Oxygen partial pressure")</link>
                                </para>
                                <para xml:id="para_5797b0bb-3b61-44b8-9ef7-ec6e2faf4913">$Units = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e22b2d1d-269f-4b24-80bb-9cd99985a7c8">23</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25ce99f4-e1ba-4761-8e89-e28a25c9c0e5">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05fb52a3-d908-49b8-8807-541731fd08e5">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1cfa318c-16cc-4560-a941-c15c145db64b">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2fd21da4-ef4b-400e-b696-6d8d01ba351d">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6033fdc3-0870-49b6-b542-4caf6d8c5ea4">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_992a0c70-6b60-4207-a90b-5ea25052241a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98f89fb5-4b34-44a4-acf6-8dbb94b8bda0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7678ffd2-38f6-445b-874e-a18c43fb297c">$Measurement = D<xref linkend="sect_CID_3618" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_1050ce1f-1933-4f59-a40a-5aaa4237a89a">$ModType = EV <link linkend="DCM_121425" xrefstyle="select: nopage">(121425, DCM, "Index")</link>
                                </para>
                                <para xml:id="para_9ff1f343-b33a-4989-a67e-b0c03aaa402c">$ModValue = EV <link xl:href="http://loinc.org/8277-6/" xl:show="new">(8277-6, LN, "Body Surface Area")</link>
                                </para>
                                <para xml:id="para_40022508-9255-4c11-beeb-663be6fc59dc">$Units = DT (l/min/m2, UCUM, "l/min/m2")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ad83965-bbec-4751-bf0b-56e544a019e3">24</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a2a2bc7-131d-4ed0-8889-3817a660f270">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_698555e4-0ab6-4637-a828-d5e28d676543">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c7ea493-81f4-4bce-978a-94d1ecbabb42">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4cd9aa25-76d2-4f63-bbf7-be91c079de2d">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_059cb7c0-cbc9-4a2c-b07d-a09d404eff07">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_56e515ba-c175-4f4a-9edb-e11cc8c33906">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_710d9b28-1792-4185-9663-9bf58ce83b7b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_885b25b9-64bb-4dbb-a09b-24ebbc957190">$Measurement = D<xref linkend="sect_CID_3619" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_f631be58-220b-492b-9b1c-a18b0de20adc">$Units = D<xref linkend="sect_CID_3502" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_694db808-d8ea-47ca-8766-485e6a96dde5">25</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02816e8d-7efd-4976-8c92-0357dd1c63a9">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0eb66f79-b8b7-4899-a77a-a7d4df12784f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2cb4e7c5-5625-4ed6-a408-020a8333d7f3">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8b7c51a-a6d4-43cb-968d-76a1fc2749d0">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2963ea0e-8b54-4cb1-89d7-57404047b9cc">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f393482-c9dd-447f-9c01-c96142f5f221">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5700c868-fecc-4da0-91d6-4efea8e98dc2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9f27010-32dc-4bc6-9173-952615758ce4">$Measurement = D<xref linkend="sect_CID_3619" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_a83a92f0-4397-4b03-baf2-2534ecf0380e">$ModType = EV <link linkend="DCM_121425" xrefstyle="select: nopage">(121425, DCM, "Index")</link>
                                </para>
                                <para xml:id="para_2c0cfcf4-2068-4925-ae87-2b6e5f284618">$ModValue = EV <link xl:href="http://loinc.org/8277-6/" xl:show="new">(8277-6, LN, "Body Surface Area")</link>
                                </para>
                                <para xml:id="para_cd3ce2d4-99aa-4cb8-8cd2-9b601563e2a9">$Units = D<xref linkend="sect_CID_3503" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5df82f9-e597-4316-ad61-a15ef1d32d01">26</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf9a626e-75f1-4b71-b99a-75472fbdb1c3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09668c13-ac5e-45ab-a6d7-1d7873c59047">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9892c58f-9396-4556-82b2-da03db54b5ac">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99425e13-611b-41d8-967d-6149b8d6d0fe">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_87df8b5c-64cd-4766-afbe-c23885537613">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d20fafec-5ca9-44d1-8200-f341c21eea34">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe47c8af-e37d-4843-823b-bddb49bddf22"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63ce9523-2f6f-404a-b646-de5a05fd3ec9">$Measurement = EV <link linkend="DCM_122227" xrefstyle="select: nopage">(122227, DCM, "Left to Right Flow")</link>
                                </para>
                                <para xml:id="para_b6f3ba83-5a0b-401a-9919-511a4394919f">$Units = DT (l/min, UCUM, "l/min")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6b491e0-bf9b-435e-9f16-bf2420f06ce1">27</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e265554-de3d-475e-be53-af65a7e5e876">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2c442d0-bc26-4854-9d1d-18083501585f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_083733e6-9200-4c7f-ae80-4912f8a7ac48">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0203f20-cdf2-4747-9a09-2879d72794eb">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fc66029d-e274-4aca-bf12-41d6cf06543c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e067db55-82de-484a-9792-fa0fd30fa65d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21a7c253-a5cb-4fac-be88-77650f0cc319"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f217e161-83fc-412e-a5e3-86957edce889">$Measurement = EV <link linkend="DCM_122228" xrefstyle="select: nopage">(122228, DCM, "Right to Left Flow")</link>
                                </para>
                                <para xml:id="para_5526ebce-d584-4892-bc40-49168f89cd26">$Units = DT (l/min, UCUM, "l/min")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0fc7fa46-4de3-40bf-bd59-cf0f6579e436">28</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3399d98-a5ce-4ba2-914a-2bd002c64df8">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_15ed5386-ac71-4b13-aca0-a222668ca357">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd653a36-c38c-4612-8811-b9d98258d9fc">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0fd4708-eb50-4da8-a154-af4da8c4a1ec">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8cf61eaa-a72b-4fc4-9ca0-4173bcda6204">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a21234a-b269-4e45-9908-f8eded22bbdf">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4ce4757-0574-48f7-b42d-91c8c527d1ea"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7e0e541-5187-4dcd-8a7e-2277e7f6e017">$Measurement = EV <link xl:href="http://snomed.info/id/90096001" xl:show="new">(90096001, SCT, "Stroke Volume")</link>
                                </para>
                                <para xml:id="para_1db144ad-b605-4136-914f-210074c0c334">$Units = DT (ml, UCUM, "ml")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5cc9c453-c2d5-41a1-a1b9-e3c5638e132f">29</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9ec389f-22e9-4999-a4ea-ffdaed3db58c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22dc6abf-bd59-4791-b75a-756a6a7fc076">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a22eb2f-3f18-48b8-a75c-dd97a78a3cdd">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c3110a7-57df-4fdb-b97f-95537898afe1">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e6d51ace-f4d9-47a2-8164-9477ed4a7580">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5692b1fd-a67f-4bdb-bc6a-0b6b1a6d2572">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8709646-e31b-4262-b768-f05c507dc928"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0c43dd58-3d61-461f-8f19-f613d463e999">$Measurement = EV <link xl:href="http://snomed.info/id/90096001" xl:show="new">(90096001, SCT, "Stroke Volume")</link>
                                </para>
                                <para xml:id="para_e4182c9d-7c6c-4c5b-85ec-f9b5bae0caa4">$ModType = EV <link linkend="DCM_121425" xrefstyle="select: nopage">(121425, DCM, "Index")</link>
                                </para>
                                <para xml:id="para_be2c6561-a895-42de-b560-f821a5d28f0c">$ModValue = EV <link xl:href="http://loinc.org/8277-6/" xl:show="new">(8277-6, LN, "Body Surface Area")</link>
                                </para>
                                <para xml:id="para_c6481dbc-c329-432d-9f7c-3b279467265d">$Units = DT (ml/m2, UCUM, "ml/m2")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82a93784-8155-486d-82a2-8bf3e57fd688">30</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7f8594f-616b-47de-8a9a-eafd0e103685">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bcfde3ca-0095-4867-a60f-486a9b9916db">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25c866ae-06a9-4ae4-bc11-148fd82fb502">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_847632e2-2650-4562-9939-9da7116865ca">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1c9571d4-2733-46ce-a7cf-09261fd39df5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b5e52404-7c12-498c-93ad-72b6a80a8dd4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef3ab13b-c10e-4fed-98de-0f0db46102a8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_855568c2-9b83-45ca-867e-9db4b8058b03">$Measurement = EV <link xl:href="http://snomed.info/id/268384009" xl:show="new">(268384009, SCT, "Total blood volume")</link>
                                </para>
                                <para xml:id="para_57e6494e-59bd-4425-970b-c1c377ffe8a3">$Units = DT (l, UCUM, "l")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8443cdcf-28c1-4b08-ae83-720e94a5a6b1">31</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46146e08-1368-47e2-ad84-17cf87867693">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d985fbd1-98ef-452f-b6a5-817e9af5f1f3">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63a0ef11-2b1c-4c29-a632-8bd042b78ed9">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_40768cb0-30bb-497c-944a-e0e076597377">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0a57d737-3c79-4c75-81d8-ce2dd9a82249">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9425958c-8734-462c-9015-a104989b51c4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61ab0d22-c2ee-40ca-94d8-05a41317a867"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_653c4c6a-ce4a-4ecc-a917-8e4a50eb2532">$Measurement = D<xref linkend="sect_CID_3667" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_0749fb44-be1c-49c0-bff9-5658abf620ae">$Units = DT (%, UCUM, "%")</para>
                                <para xml:id="para_cbe3f7db-22bc-48bf-953d-56df6b5672f4">$Equation = D<xref linkend="sect_CID_3668" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3570" status="3" xml:id="sect_TID_3570">
                <title>Summary, Hemodynamics</title>
                <para xml:id="para_596daf2f-6fa3-4659-9529-096c6a72e8a6">This Template allows the recording of any significant numeric measurements or findings.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_d608dad7-2f20-417b-83ca-8b64c2df68c8">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4bce6bbb-c248-47a2-a0ea-9adf0a07ce29">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_c9a054c6-ea82-4a19-92e0-441a46a43765">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3570" rules="all" xml:id="table_TID_3570">
                    <caption>Summary, Hemodynamics</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2a27db0c-3ef6-4720-9686-94d4a43e9fe4"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fcebc21e-235b-408f-9ee2-5004cf0707a0">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8d79099c-b6ae-4ef5-a395-da21374369ab">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d086f6e3-c0f4-4e5f-b64d-c0d1cb7466b3">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_677c6757-85c8-4409-b390-a4a5c10d708f">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_af83cee1-13e9-4bfe-bb74-b7e7a9b0148b">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ff072cb-7b75-4f34-8df4-ea7b1e96d2d2">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_50aed641-e0af-43aa-9e30-13340def12cd">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cccf688e-370b-4829-a544-98bb859590c0">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a1a965db-da71-4cce-ab47-b355df9735cf">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d568105f-c505-4df7-a595-1d0e102bc13b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_236a1144-39da-454c-9803-75ddf2822f6e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0cdf4dac-ec20-41c2-9838-a6a76809c731">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36f3bb09-4b00-40d3-b302-901671fb5b43">EV <link xl:href="http://loinc.org/55112-7/" xl:show="new">(55112-7, LN, "Summary")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d1885e3e-d45c-4746-96e8-a5b95d402654">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c7c290d1-3c7e-472e-9eb5-8db53ead3692">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9528a603-0bd1-4df0-98f2-1ee59840890e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_889d363d-295d-481c-a5d1-0523aec6f04b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_89264419-eebc-410e-9982-cacccc6eb9e0">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fdba5531-59d2-422b-a9db-9a94322272a0">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05cfdee4-4c4b-426e-b1e6-daaf06717d54">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5fe7deeb-6082-40e0-86b6-498d89927a5d">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74a502f0-4250-4e45-b7cb-998012537cce">EV <link xl:href="http://loinc.org/55112-7/" xl:show="new">(55112-7, LN, "Summary")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0983bc89-2a78-4e77-8e5e-34eadcb4e4d9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2e3193dc-167d-434a-8592-342d03e43963">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_945cb2b5-8094-4774-9bde-fb510477456b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aeed13c4-c07e-4ade-8437-474f0831649b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_12150b96-73a6-4ff3-b6fd-cbe5ff3667dc">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_78909edc-10d2-482a-8104-b16b52034c6f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4ce6929-f969-49e8-9b80-755b8a1a82aa">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_395271d5-c1b0-46de-8dc5-9ad581cce8f7">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_477533ca-ca25-4287-bf74-d5067328c260">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5a921698-cc6f-46c6-8ace-ae0bba74260c">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_39495b94-9d7b-44e1-9528-4d1d3f7e999e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9dc11e50-db9a-4c06-b86f-55fbfedb4010"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d89812c7-c4cc-40a5-b3bc-810704fb1011"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0695fc51-a679-4172-a1e9-3d033a55665e">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_247b882e-0275-4cf5-8bd7-753dc946111b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2dcd944-f401-446f-92a7-0c4770cc1a80">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e8bde23-8d1c-4122-ad87-5c5f6b7c4a62">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99efa5ae-30b7-4f94-9a97-285c45591b93">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8fea61ae-e045-4274-82de-b8d0c9981583">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a8c45281-7a29-482a-9ba9-a11df20b3e4f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9936a84a-3ef4-4bbb-946e-7aa0c482060b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59d6e8a3-eded-48cb-a8c9-d35df7cadbac">D<xref linkend="sect_CID_3640" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_817d5036-9ab7-4b18-b775-addbf8469974">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ab01537-bb98-46d9-98ef-c574603e6b4c">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_569d5084-eb73-4b08-8cc7-a47e1f916127"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8bcb6373-a95a-4abb-9a5d-a29322bd9da1">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4035e1e5-6883-43cf-a0c7-609a5d3179ff">D<xref linkend="sect_TID_1350" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_77f3f892-5ec4-4e3f-8509-ede38a8b66e9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_35fc8093-0424-481a-bf90-bc7bfae42c4e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a5469c4-b73a-43d0-abb8-6ea94b635b0c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84d3d37b-2986-412b-b72a-3738ab2ba650"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_deab4d11-8045-4b7b-8c0b-d0232226faa3">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c930704c-cc24-4aea-98b0-b1b2f778813a">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8d3f115-4436-4cfe-94cd-cb465e3fd07f">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c86065f-2fdd-4dd9-b0c4-20c06444fcea">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61d5a9d8-927c-455c-9189-649c19492ecf">EV <link xl:href="http://snomed.info/id/246112005" xl:show="new">(246112005, SCT, "Severity")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_63a3e2a9-ac1d-4a1a-9777-6bdf8fc98ef9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6472fd4f-5293-4995-89e0-c3ba6d270457">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6567530-d41d-4012-9fac-be20301ec9fa"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2d4fadf-0c11-4c3d-8da0-b0355dd7dc53">D<xref linkend="sect_CID_3716" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1fc54ccd-7db3-42d8-ad65-8c7e8261b24e">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5cd15ec3-73c1-4272-b03d-835fe30295f1">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a54da040-6eed-4277-bc63-82480a016edc">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe777616-b6c6-4e3f-9705-322162418c03">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10be9d1f-908e-4c0f-84cb-ae6097c748d1">D<xref linkend="sect_CID_3641" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f2b91472-0145-4fe5-9e77-55b61049a006">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_331b9dc3-d5a0-4d66-95d9-e8b744749e29">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af12e3bd-47c8-4afa-9500-8e37e9ea3b60"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a345bfb-134d-4225-a799-52687be3b323">D<xref linkend="sect_CID_3642" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc8c5e63-4027-4b0d-b7b7-449b0041a4f3">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d284bf5-dfd3-407c-8ee0-a82728cb29c1">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_409e7b3c-bad2-457d-b8f4-a654f69307c4">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04903a8c-2fa1-4a9c-9b6a-6ffa14e54e80">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_90f7b098-3991-40ef-abdc-9705bfa88f4c">EV <link xl:href="http://snomed.info/id/260905004" xl:show="new">(260905004, SCT, "Condition")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eced477d-83ee-46f8-8a94-928525c07eee">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_723e928d-8a83-4157-ac41-2039e5a17297">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88df619e-07d0-4800-8935-45fef27f59d7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4d15e2f-c449-479b-aea2-9d4ec4690ad4">EV <link xl:href="http://snomed.info/id/414576002" xl:show="new">(414576002, SCT, "Large v-wave")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0fcf3c42-ffb1-4d01-8641-0eed762b4609">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_566b38fb-733c-4392-858d-27d4c394f8cb">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1748e068-a079-4e44-8b96-d820b8db59b1">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3cb54da-494a-4ca1-b8c9-970ad8264dc8">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a806c79-20f9-45bd-ad12-bf56d83702ea">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ab8d719d-d813-4c69-9e0f-ca766020109e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_920757b5-c612-4874-99b0-aa08369b8b0e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e17bc8cc-e652-4b0f-8fa0-05cd36d53d67"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec68272c-fec0-4ff1-8c40-7c6072224825">EV <link xl:href="http://snomed.info/id/413985002" xl:show="new">(413985002, SCT, "Diastolic pressure equalization")</link>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3601" status="3" xml:id="sect_TID_3601">
                <title>Procedure Context</title>
                <para xml:id="para_d81de0ae-ca8a-4104-9fcd-bac4159a9d6e">The Procedure Context Template describes acquisition context for measurements made or events recorded in a procedure.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ae545bb5-4199-4619-85ee-f0a93cf4c782">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_3ae5e7e0-aca2-4d75-a0c4-cb011e300967">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_6c527bc0-a63b-4e5e-b0e5-89a6885afd76">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3601" rules="all" xml:id="table_TID_3601">
                    <caption>Procedure Context</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_801859a6-3784-4d48-8331-f280673efe9f"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7d3edc25-9da3-439c-a8a5-558c35ad622e">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d44da2b4-989c-46b4-9d5c-4e600c199cc8">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_249650de-b158-4e6f-89f2-1f303085865a">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7c1ab287-e17e-4c20-98bb-67a898602c99">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5f6eac05-861a-4332-a164-164e9c884759">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_de78e7e6-01f2-4ef4-815d-f5d2573c159b">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ab046714-085d-4de1-a215-eefcbcd616bb">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_51468d41-12e8-41e5-879d-7c19c16f4647">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a01e7bbe-0fc1-47e3-8b7b-3c308dd08100">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_23eb41ff-797a-49b0-aab3-c800277ec1fa"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5be3e0e-4166-4968-9f02-f008bf615865">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af0c4ea9-d303-43ad-9db7-ec14706c761b">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c0e11c2-94a0-44b1-8d20-bdaf90c90194">EV <link linkend="DCM_121065" xrefstyle="select: nopage">(121065, DCM, "Procedure Description")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_605e95f7-8b08-46b1-bc22-7f0ebd1af426">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ad1e657a-4c62-42aa-a112-b73c3fbb79fc">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1df9a430-5f47-407f-adae-145ffa2e491e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_283ba431-4333-4350-a0d9-84c4e2fa6e1c">Defaults to Value of Study Description (0008,1030) of the <olink targetdoc="PS3.3" targetptr="sect_C.7.2.1" xrefstyle="select: title"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_367188b9-13b1-46a5-9e81-92213b0c5b6e">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed4f9e6a-9e07-4d33-a1bc-67c55b95805a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad5020d1-ac43-4cfa-9ca1-598ffd973c29">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79630503-0083-449f-8921-0e03ae9d192c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_418a0c0b-6f37-4165-8f44-0fa587940b5e">EV <link xl:href="http://snomed.info/id/363703001" xl:show="new">(363703001, SCT, "Has Intent")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a83065b1-82a6-4699-8e30-e852f510b5f9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_90b0ab70-9593-4a4d-8d9b-b68b2e3c78d6">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d4855b4e-18db-4ced-a052-15c43c5b0da5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_110cb875-1fdb-4837-b0cf-528af4e45c2a">B<xref linkend="sect_CID_3629" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce28b49a-a704-4c54-889a-969c75fc2daa">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1dcb4b8a-53f1-4586-a461-dce3e17350ef"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b991a224-e488-437d-82b2-afcfa59e11ef">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f31e95d9-e3ea-447c-ae80-e034ae032ac0">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d4724b2-ab6f-4da6-828a-fd5cd8b0d400">EV <link xl:href="http://snomed.info/id/260870009" xl:show="new">(260870009, SCT, "Procedure Priority")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3038104b-b8e4-47eb-a9be-ba552e9ab352">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_24c33862-c11e-4e1b-9645-4eedcb8a9b38">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a535b3a-389c-4c18-9b72-ecd7e2d37392"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2ab1eca-427b-4702-b2eb-18132b5a03c8">B<xref linkend="sect_CID_3414" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4de9cf28-9c14-46b0-b6c3-48ed35f0cef0">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3606b63-b8a1-4681-8808-a2a1988a2c2d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8aeb0489-09fd-4a88-940c-b65c6a6d156f">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f230fca8-aef9-4b0d-a15c-0d4d6a2167d2">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_095d17b6-ef0f-4baa-8052-7c0b4c37148f">EV <link linkend="DCM_121023" xrefstyle="select: nopage">(121023, DCM, "Procedure Code")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6739c9e8-c299-40cd-aebb-7a993928618a">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a09048a1-a352-4fc9-9914-970f64d3c087">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b91cd14-272c-44d1-a8fa-d3efc84493bc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9889740a-b780-4f13-bfc1-5dcbc2ca7269">Defaults to Value of Procedure Code Sequence (0008,1032) of the <olink targetdoc="PS3.3" targetptr="sect_C.7.2.1" xrefstyle="select: title"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3602" status="3" xml:id="sect_TID_3602">
                <title>Cardiovascular Patient Characteristics</title>
                <para xml:id="para_2bf8e023-1cbc-4aa3-9c5c-d774d4c17aac">This Template describes the characteristics of the patient that are specific to the current clinical presentation (visit). Patient Characteristic concepts in this Template, which may replicate Attributes in the <olink targetdoc="PS3.3" targetptr="sect_C.7.2.2" xrefstyle="select: title"/>, are included here as possible targets of by-reference relationships from other Content Items in the SR tree.</para>
                <note>
                    <para xml:id="para_3c5784b6-7758-4151-a273-22170e1f484c">Several of the concepts in this Template duplicate concepts in <xref linkend="sect_TID_1007" xrefstyle="select: labelnumber quotedtitle nopage"/>. The difference in use is that this Template has those concepts as primary observations of the patient, while in <xref linkend="sect_TID_1007" xrefstyle="select: labelnumber quotedtitle nopage"/> the concepts are used to set (or reset) the context for other observations.</para>
                </note>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_e27c4691-7d85-4f4b-90d3-fee1dffee7c1">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_88926ac7-791a-41dd-9041-248e175fa1c8">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ef2f1f91-439b-4ef5-87c4-7c3b2a3fe247">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3602" rules="all" xml:id="table_TID_3602">
                    <caption>Cardiovascular Patient Characteristics</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_21e69481-23ec-4f67-b17c-e0d19e3ac12b"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ba09e399-67b4-4c67-9b81-d6d7ef97cfc0">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3513edb0-da7d-49eb-828f-e8e97ee043d5">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc9adf58-5285-4032-a772-bd05e00ddb4c">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a17e9c76-a8c5-4b7b-9eea-0646cf71d3c1">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4efdeaea-68d8-4923-90a3-e342aa4f0a12">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_56b45346-3e3c-4ac0-846e-8e94c418199f">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_371b913f-1192-4788-bae7-f398eccf6163">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9f7467a7-72af-435f-910d-5ce0017c62bb">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0956a892-b3f8-4595-8ff5-e3da1c0b7345">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_45b87f3d-4656-49c0-9575-32a06405237e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_897f5f83-b667-4ec0-8336-e2d6dc0dfece"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52ef4146-2f0e-443f-9a75-ce903031f8ec">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1f356a5b-8947-4208-a42e-83168c41266b">EV <link linkend="DCM_121118" xrefstyle="select: nopage">(121118, DCM, "Patient Characteristics")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8db943c5-16e3-4535-aa54-0f2163f518aa">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f8b10039-9c54-44c2-ba1c-6d66a170043d">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9ce3b89-1efd-44aa-a2c4-9936c0dbf830"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e9aa5f3-5d11-4e81-94fa-673af79e5604"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1dec6539-bd67-420a-a134-cb500aeb8cbe">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1cf82f3b-b6ed-4374-bb57-f5ac4322d39b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d6ce3db6-ce07-4405-98ac-d283ffa2d293">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3b69b15-2577-487c-8209-7cada17322be">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79b258bc-1bd1-49ab-b7cd-dfe4b4733d49">EV <link linkend="DCM_121033" xrefstyle="select: nopage">(121033, DCM, "Subject Age")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_483ef2f9-881c-4a01-912f-76d876068433">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4c99fc8c-a77d-4151-a24e-d1323600b09d">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0c4fdc6-b513-400f-b94c-0eda25328b13"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0dc937d-7e75-4af1-8e1a-bac376acf199">UNITS = D<xref linkend="sect_CID_7456" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_23e34887-69e4-4266-8e35-aae51579d7d1">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9861d7c2-3cef-47d7-ac83-986cdaddd6e6">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c9b836fe-e63f-456f-a499-e5b32d9cc33e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42fe16c7-f3f8-4fda-a940-aeec69e589bc">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29815156-7e06-4461-84ed-61b065ce0903">EV <link linkend="DCM_121032" xrefstyle="select: nopage">(121032, DCM, "Subject Sex")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_731718ec-c4e1-4172-ac67-5316a7b79b6b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d3ee8ed4-2bcc-4b59-ae0e-f322b9f7fc3d">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75b989f7-f19f-4c74-bd72-c42587305c4a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_748eeb96-762a-435c-8ae4-4431e04dca53">D<xref linkend="sect_CID_7455" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bba04a7c-7a65-43cc-8026-44ea296341c4">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e98cf8ae-b092-4b2e-a530-406fd102ad19">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25328804-cea3-4267-ba2a-b9eb14cdf0c7">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_531a36b9-8958-4bc6-873b-d00fe4e31462">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_14c88f2a-86ac-4eb3-b1ec-634cd17c19b9">EV <link xl:href="http://loinc.org/8302-2/" xl:show="new">(8302-2, LN, "Patient Height")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cae853d2-efe4-4818-8c3a-976fe43c2c05">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dbf04b24-4a1e-4a20-8537-7933bc073408">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_68bb9332-f0d1-4f56-9999-d24741bfa2b7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_266d273d-8a52-40b2-b0f0-28d525137135">UNITS = EV (cm, UCUM, "cm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6991dc46-b243-41eb-b15d-eaf1431185c6">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_990fdbad-2e9f-4bda-947a-3b09ffa108a4">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b8788434-389a-4b96-b6bd-20a93f0f618f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0db7f10f-86b0-44eb-9dd8-190467972c86">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e55c29f-957c-4903-9ee1-03947af8b973">EV <link xl:href="http://loinc.org/29463-7/" xl:show="new">(29463-7, LN, "Patient Weight")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ba489287-69b0-4d27-8041-6d4203ccece4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5efd55b2-8523-4b77-b1e0-03a998827ac3">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2305939f-a91b-46a4-bfd8-1570298587b7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c5e3813-816b-4e0a-b06d-18daf56bc7c3">UNITS = EV (kg, UCUM, "kg")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_387cde97-a043-4b66-8b92-5f0c139a6fe6">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a35bce9-7bfa-4999-b986-6856af0a7c56">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4237f9c9-72cc-48c9-af98-667ea340b2b3">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3788d8f6-5b3e-4cf2-a8d0-359f6459942d">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a7267ac-c2e9-4640-9775-a483ca0887b1">EV <link linkend="DCM_122221" xrefstyle="select: nopage">(122221, DCM, "Thorax diameter, sagittal")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c4231e24-69eb-4fa4-97ba-8515a32386b2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ef99fae7-32db-49ff-8f4a-a1b7fcfa6181">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b8942a9-a3ee-43c7-b6fb-c73ed3772a12"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9247a056-5f59-41c7-86c3-66d3049fd167">UNITS = EV (cm, UCUM, "cm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_001b5755-75f1-4b52-9ce2-8097f82af352">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_94217242-70ef-4db0-9bbd-b6e2c30f8204">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_604fd3fe-bc6a-4c5c-a44d-8be57f071cc5">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4bc2c7d3-be57-4ff4-97b2-64363ef3013b">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2caa783-05ea-4f16-ba1f-f029416f834a">EV <link xl:href="http://loinc.org/8277-6/" xl:show="new">(8277-6, LN, "Body Surface Area")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2c654f1f-6c91-44cc-b9dc-0aae06f94139">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_12c22028-bb7a-4942-b4b1-92f28f61f387">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b379306-4c7a-40cc-a27c-f2fa4fa0b62e">IF BSA used for indexed measurements in SOP Instance</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7515cf86-9764-48a3-bfee-3c595e8116a4">UNITS = EV (m2, UCUM, "m2")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e775faf4-da36-4fac-9e85-cc0abd376c97">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b9183c9-300f-4d63-8927-3164d87298d8">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1af2c1f-624e-44dc-b217-dd7a2e33a303">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_647e4575-1547-4d5b-b008-634e43836342">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4da0a0d-ecf1-4a84-bc5a-1219167be490">EV <link xl:href="http://loinc.org/8278-4/" xl:show="new">(8278-4, LN, "Body Surface Area Formula")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_33455692-54a0-48c1-8c87-d601d25915f5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_801d6d93-d258-4829-81dd-f5685650bf28">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_601e5249-b362-4efa-818b-9056bbdb632a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2febd084-426a-4da7-902a-190ec969af5f">B<xref linkend="sect_CID_3663" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a38d539-1ec8-439b-8931-0de1287ee9fb">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a99d183b-926e-456a-9487-bffd3a31fe7c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ad83aee-3762-471d-bba1-eba495e5a1ff">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d391d0c-3652-42bb-9ae4-db861a6c5e48">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aebc1f13-bffb-4f81-bf13-b234437c605c">EV <link xl:href="http://snomed.info/id/60621009" xl:show="new">(60621009, SCT, "Body Mass Index")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fc6312a8-e0d4-400c-a28a-ab1e48dad24a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ddae69c9-ca0c-4490-a34e-b4816c767bab">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b572dd73-951a-487a-8f27-9c48459e8054"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84454a86-07ab-43e3-8581-93a156662458">UNITS = EV (kg/m2, UCUM, "kg/m2")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b3a2006-d5dc-4c88-b4b4-e44db760efd1">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e589594-c2ff-4628-882c-ef8eb9c7bf89">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2919881-0fff-43bf-9736-102d474f31d6">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c70eefc2-0460-4f12-a91d-1180f2b05c00">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6371a79a-2f5c-4dec-b65e-8d12e70827ef">EV <link linkend="DCM_121420" xrefstyle="select: nopage">(121420, DCM, "Equation")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_534c8aa2-0502-4419-a931-49c35f8fb947">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4aeb4c38-17d4-4ae0-9989-bb6846e412f1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c9d54498-285a-4725-87d9-d57114ac2405"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2536ef1-a95e-4940-be26-57ee1f0a3e88">DT <link linkend="DCM_122265" xrefstyle="select: nopage">(122265, DCM, "BMI = Wt/Ht^2")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee5500bf-d01d-45ca-8425-f737de4885b2">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e64db5c-4924-4f70-9223-386f44432cd2">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6654f111-e175-431c-b904-43079c78a268">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9167be18-e29c-40d9-a1e8-ae8506cc3941">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3f917b3-b375-48be-a684-a474983b9b58">EV <link xl:href="http://loinc.org/8867-4/" xl:show="new">(8867-4, LN, "Heart Rate")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8cc3d79e-5b89-4ced-8b12-3b0c7e94cc98">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1fa305d5-06e1-4916-b6ff-ecaa1293a7d9">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea1813fe-541e-44fd-83c4-0fb1bf3865c1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e875847c-035e-49c1-b367-04736bc5c3cd">UNITS = EV ({H.B.}/min, UCUM, "BPM")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_28290754-3109-4d4c-b042-ea32dd91db82">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9527fb7c-6058-46b9-9c26-df0bf18691e4">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6448b306-dac8-40e7-a7f7-58efebaab773">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0aa018db-9f44-49f9-a7a4-b0c6cd009aca">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b4226c5-f0ef-4df2-a45b-7cda6ad46448">EV <link xl:href="http://snomed.info/id/271649006" xl:show="new">(271649006, SCT, "Systolic Blood Pressure")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_be77d0e3-ba93-4185-a87e-525f52756a05">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9cde4616-dd15-4918-9a10-6cb27b8b3515">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4cd19db-2a38-4bdc-a1f8-02467ad6db44"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_66354bab-d380-43fe-b5ef-743fb9e221be">UNITS = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ecbef0d-b3cd-48f9-87af-5bffc31fc1c6">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c750ebc4-70f5-4c69-ac5a-d6bd6be6ce39">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2eb8c457-156d-4d7f-a110-2fdfa8f49ef1">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ac3d38c-b9c5-4a3b-93b7-9cf5d81851e7">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ea39aae-974b-4378-ae3b-121a115e0231">EV <link xl:href="http://snomed.info/id/271650006" xl:show="new">(271650006, SCT, "Diastolic Blood Pressure")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e98e948f-d2b5-4508-9c94-257191c1e4f6">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ca795136-61b2-44d2-b6b2-dbc594a55744">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a3433d5-cc8e-4e07-a791-50473c0b3931"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0510444-ac6e-4715-8fb5-0fa7c580ef09">UNITS = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a4649c6-9993-4c17-a75c-5bd9c8f83629">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e8c368cc-2a3b-4fc5-9156-31f847ea9e26">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0b46f82-8694-4deb-8666-1a3269b16f87">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b61360b-3fa8-4dfe-91b5-91f4647048d1">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ac100b5-d3ce-429e-8131-5b9b7649bbc2">DT <link xl:href="http://loinc.org/8884-9/" xl:show="new">(8884-9, LN, "Cardiac Rhythm")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_54f3426f-b422-42b6-9465-7b7b5faf8615">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f3ebac79-8f9a-4193-bc0e-de2465f7482a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f4133ca-ba3d-4461-a1c8-dc51944634c0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc8d1c08-1598-4f24-9adf-e973efe8b0fb">B<xref linkend="sect_CID_3415" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e2582b3-4433-4589-9e9a-e8a1d77453c7">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_793ad646-e46b-4861-ae56-016124ba1846">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8828c146-6169-4fcc-8f13-f39b4098b760">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_089f675e-37d3-4ff9-9147-5c35d5f786d1">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_531a0a39-0b34-4cf6-93d4-df7b6a124944">EV <link xl:href="http://snomed.info/id/248366000" xl:show="new">(248366000, SCT, "Chest Circumference")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8305df1a-0cbe-4228-8720-7ce35c09d0ea">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dc21f4de-7b4c-4a44-89c2-af063f08a80f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df980217-9a4c-4982-863d-ace02bdfb8ef"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f25e284-b9ac-4ac6-bf48-1b6618cdf09b">UNITS = EV (cm, UCUM, "cm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b98f47b0-b146-4624-af3b-47d0bd08908e">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1dd8d783-1a5d-49a2-ae1e-b26657493a81">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97e60e89-1465-4f81-aa8c-4af6d1c8f638">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b52685a5-3794-46a2-ae23-82feaf544ae7">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f82d9ea-0de1-4dfd-8da1-564c1b2543bc">EV <link xl:href="http://snomed.info/id/248808008" xl:show="new">(248808008, SCT, "Breast size")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ba52bdd0-4e7b-4a60-ab71-66370c59cd0f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e80ef9a1-0341-4acf-ac4e-cf07f0ec8909">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b7b4ae2-f00a-44f8-b340-df1cd35ea405"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2c5dc33-5900-42cc-944f-cbd30e27e1db">Bra size as text string</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7da9f86-33af-4c15-aa91-e3e1b5d73af6">17</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c61df81-a1c7-4602-bcfe-8ba7a120855e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3712f5ee-844a-4c4b-8db8-7bec75c131a5">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99cc4e17-d3ba-4033-9f4e-f58c796b5f1b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b05665d-a7fb-4d7a-b476-2a32819c9234">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6dae3c47-889f-4d14-920c-915f3056c5e3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1a3c9e40-8bf2-4656-91ee-d312b37777b8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3f31714-39b9-4abf-9bdd-daf73b40872b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_275d93cb-7205-44cf-a4f8-f77a2e1e3075">D<xref linkend="sect_CID_3202" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4345dc1-d008-42f6-b704-fd03ae59ce0c">18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_658d0a04-0441-42d8-892c-30ee6ea41c15">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0897955e-fea6-4ddf-837f-780dabc6dbfc">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f2d7fbe-cf5d-47f2-a30e-e6c587c79c8e">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_772539c6-0d2a-4d44-99e3-3ea68f482cf4">EV <link xl:href="http://snomed.info/id/429160000" xl:show="new">(429160000, SCT, "Functional capacity")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b5b65f2e-0f12-456e-a8d2-1bef286337b1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f8556995-467c-4d61-8e6c-487f0a6f342a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea666e01-c2ff-450c-b2ef-75aab6d9a788"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67e66d12-773e-46c2-b58c-1af63e780160">D<xref linkend="sect_CID_3719" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_afed9957-1ffa-48fc-9ba3-45e577b3acad">19</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba9ec61e-1490-4bd8-869e-19685d3f3563">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_427af914-2f02-4fbd-8995-f5f67a74df15">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d465642f-9e74-4d93-ad30-f259e86f3b3c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f445ca47-f620-424a-b395-3849c60972e4">EV <link xl:href="http://snomed.info/id/429160000" xl:show="new">(429160000, SCT, "Functional capacity")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0705d10d-b582-4bc0-8be6-fcddeaf3534c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5351a995-09df-4db4-ab78-3570f445d0a1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59058baa-711c-4841-b534-fa6adbd0e501"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a0d19a9-2395-44a4-b520-67f1372565ee">D<xref linkend="sect_CID_3736" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d2b9e1c7-0bdc-47e3-bf54-d030713d7a14">20</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9092c60e-c631-4a48-b449-05b33c5c9fd3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af0ed75e-e266-4dc3-a67d-39edcde915d5">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35ee4f01-cd06-4ec2-b59d-0b2ecc1f0188">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f86abc75-943c-456d-a950-e47f648e7dff">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3d357631-a9d1-427f-bd05-1f67fe957e63">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_318e5df5-291d-4e49-854e-1dd5b83e476f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_95fa915b-a965-43c4-bd96-2abbf79d1765"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c02a518-20bf-4873-98f6-45aa0244622e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3efe0989-a302-45fd-a5dd-406a150bffba">21</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9915f802-78d0-4402-a4e2-2326901d139b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63ec0fef-fdb6-4371-8138-76939efce324">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed8442bd-b7e3-43c3-975b-5fb295a0d7e0">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd238187-a422-4583-8f68-8b0a15bdd74f">EV <link xl:href="http://loinc.org/55108-5/" xl:show="new">(55108-5, LN, "Patient Presentation")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e5953b81-1a68-4c8d-b363-0054312325af">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e96e343b-6529-4c41-92be-b64b4a507a29">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab769634-34d2-4efb-9228-dc0fcfc0b6e7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9c3a58f-bea8-43db-9651-12518860b224"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_453978ed-2017-44e6-99b1-ec96e41565b4">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02a1764c-bfcf-4c2d-b85e-0a47048755a1">Rows 11, 12, 13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4bea576-7707-4b7a-a8dd-7bea01f5abf3">Cardiac vital signs, for use when the SR SOP Instance does not record vital signs at multiple procedure phases or stages.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f8e028f-742f-46a1-8ce2-1fdb8f1bd760">Row 16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe8137cc-ff98-4d50-9b1d-f4bdd720057d">Breast size for interpretation of attenuation in nuclear medicine imaging</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3603" status="3" xml:id="sect_TID_3603">
                <title>Procedure Environmental Characteristics</title>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f1e36f3f-a6d5-47af-b4f6-516498155edd">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_6910b118-f685-435d-9353-27733e28228f">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_3d380558-5316-499b-a62d-eef42ee5a28c">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3603" rules="all" xml:id="table_TID_3603">
                    <caption>Procedure Environmental Characteristics</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6597f0c2-bc52-4d50-b61e-2929424efe7c"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bb5ca162-39cb-4536-8b46-e82a2fab55f5">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5214a84e-ba36-47be-a797-ab05c2f50c14">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_45128415-cb2c-4762-a55a-6591bf73f033">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_38a7f773-22f6-40a7-9eaa-4d0885739657">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ccd58871-a3c0-404b-8796-fb70f6fe9690">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_08a3694c-1dbd-4456-8a10-01e90f0a45a2">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bde84610-350c-4057-ab14-1f83bdc8a659">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_12916735-054d-4e13-a9b1-d292633979a4">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_686a7eea-7cb1-4b67-a81d-07754a147b0a">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_205b582f-00db-4d82-b071-15f943573de0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b16c1b01-b134-47ae-802d-53e3476839b3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c9e22f21-ef6b-4486-addd-a3dada14a3bb">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a90ec9be-3482-48d0-9cfe-af2ae10263de">EV <link linkend="DCM_122222" xrefstyle="select: nopage">(122222, DCM, "Procedure Environmental Characteristics")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_352187b8-11ab-4546-abbe-87bde5ac0e3a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_78b0b101-7132-4cb8-805f-2938b82c4f5e">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f1cdc44-8ab1-449a-8bf1-34484e94fb72"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4edcab4-3c8b-45b7-a5fd-17940c8af22f"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70fa312d-64b5-45af-8c2c-e13db636787e">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5e94e9b-7acc-449f-9ac4-df1b631d9c0f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5d01e38-d399-4aef-a20f-1a7f83c0a5c4">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3c09fef-f06e-4af9-b8b6-373dbcedc0f6">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f077cdc6-b06d-485d-9fd5-9c507c65917c">EV <link linkend="DCM_122223" xrefstyle="select: nopage">(122223, DCM, "Room oxygen concentration")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e2d22648-f88e-4e57-b8de-7650d1ad2b5c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c916da76-117a-43e0-9cb0-44661026c2ef">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a55b3867-96a2-473f-a8af-b718ae8db0d0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_582bd0fd-487c-4244-98eb-20cde5db47e5">UNITS = EV (%, UCUM, "%")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3161ec48-4448-449e-bd10-5bbb57b3e1fb">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f634cc8d-4cbb-49a8-bd5c-7028831c0825">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6a58a0a-2b9a-4043-9220-028ff95529ea">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5610b795-432f-4ae5-9560-6c080b65ede7">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3bf9d48-b3da-4838-af49-2afd00a7b590">EV <link linkend="DCM_122224" xrefstyle="select: nopage">(122224, DCM, "Room temperature")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fc52599f-7af8-4fcf-8603-9fde791f183d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7ac3089-04de-4b98-9816-fbc599a518b8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22697bc8-241f-4882-8199-9e1f142dba70"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6412ca82-9dbe-4879-afbb-bad23a229d5d">UNITS = EV (Cel, UCUM, "C")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16a5bf06-006e-4271-b7f0-90b1377003f5">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a47aac6-25eb-4ddf-b017-e091c0f50e88">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0abf876-62bd-4b65-8758-1893027b14c1">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cecc4fec-dcb1-4d1f-b83e-0ea0211fb963">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d59222fd-3732-48c6-9890-37f7552fd208">EV <link linkend="DCM_122225" xrefstyle="select: nopage">(122225, DCM, "Room Barometric pressure")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7b644166-9879-47fc-93a3-5076b74e14ce">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f804bf2e-7022-47be-9443-bbc20209da40">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_622e1083-437f-497b-9606-570bc529d656"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_079cade1-892f-4c6e-ad72-487364bb3b83">UNITS = DT (mbar, UCUM, "millibar")</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
        </section>
        <section label="ECG Report Templates" status="2" xml:id="sect_ECGReportTemplates">
            <title/>
            <section label="TID 3700" status="3" xml:id="sect_TID_3700">
                <title>ECG Report</title>
                <para xml:id="para_d88495ec-b779-492c-8da9-ded361357296">The ECG Report Template is the root structure for the representation of analysis of an ECG waveform, potentially in comparison to a prior ECG waveform analysis. The analyzed waveform may or may not be stored as a DICOM SOP Instance.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_313ef7fc-812c-40f0-bc59-b2de6491ecc5">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_d8e6210a-9111-4e7a-9593-042051439ddf">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_406535cb-afc7-4b93-ac6f-b501a7038b38">
                                <emphasis role="bold">Yes</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3700" rules="all" xml:id="table_TID_3700">
                    <caption>ECG Report</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_984b6c10-a906-42b9-a81f-ed40e8d9b5c1"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_670d811e-8f28-45d7-b3d7-998d5f24c032">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6d13bb7c-5241-422e-a0bf-7f63be392921">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1e67e84a-63b3-4ef2-817e-c9670c61ab51">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6b7a3368-3939-4dd3-a091-4aac39294dd5">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d8a590bd-7fbc-4ef0-a992-3e2131eb0d93">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bfc7b876-861c-4901-9301-750a168b017c">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c3ad38d8-7fce-4ed8-a6b4-13d9770d3858">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0e6af76e-1cbe-4dbb-880d-9cad2ce51cef">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ffbf7f52-7896-4d8c-8a67-b48c30912fae">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75d931a0-bd09-4232-b471-c4aaa66ea587"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc4effd9-7672-45ac-bcb2-bf63052389ea"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9b3e1b9-e925-465c-9f90-1bfa859739c5">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f638eaa3-f8ad-4e42-b273-e8ad453d5cd3">EV <link xl:href="http://loinc.org/28010-7/" xl:show="new">(28010-7, LN, "ECG Report")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb3fbd08-5115-4c60-a0f1-0bb991ee9290">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e6ee0f28-3d61-4765-a1d2-78a0e6b0576f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da0180b1-1294-41db-8589-494ac962aaf6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5343ec9d-41c2-4916-a0ff-76757767c59c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_32c67170-ee77-4b1a-a299-f0f113cb1c42">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_864354c4-bbf6-4dd2-80ef-91b0f3b47ff9">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee76fb6b-05a4-4f37-9d19-33f5274ba353">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39e827cf-6c2f-44ad-9d4a-3ae299d65227">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46681d65-7e1b-4a85-afcc-b0ed14c118c8">EV <link linkend="DCM_121058" xrefstyle="select: nopage">(121058, DCM, "Procedure reported")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_695255c3-4148-4928-8942-09611e92c64e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8ccbbbe6-d037-4111-82d4-7bfdcb2003e2">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e56691d-a33c-4d30-9a0b-4530e288f1da"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43037615-77d3-4966-b2ca-31e326f1bdce">B<xref linkend="sect_CID_3670" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e753eb25-a292-40c0-8e85-638b94fe0fb0">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3b798b5-fbf5-41f4-b2f7-6941c7535d42">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad53ca3f-9027-464f-86f4-d784ed458b11">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a409c2d-e7ab-4972-95d4-b7a6fc286a82">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99da775b-bd0d-421a-b3ee-1fe6f76f925b">D<xref linkend="sect_TID_1204" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_51f10e3f-d5ce-4452-9d6d-9baae7eaf17e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8770e286-5ce2-4440-b838-0ae4171551a8">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb93e124-4728-41da-a62d-f796e4917be1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1aa0d385-6f95-4794-9bf0-7dff139352ea"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_315ba005-11af-4122-a65c-cc68fa06d6af">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0f95a91-1bfc-49a9-89fa-5b5f050f9326">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_64e71ce1-5d09-4b43-a16a-9aaa553d9a0e">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc6b2ae4-f3c2-4343-8ed4-18f454e24ffd">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02441422-8ff7-4362-b118-0504dc82481a">D<xref linkend="sect_TID_1002" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4c0db9a2-186a-4dd0-b6a6-4e71c1a1f1b6">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_653aba0f-8abe-49f6-9273-49b1746f4fac">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d31c4433-2b7e-481a-9449-2a871c643331"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b35d9da2-85af-41fb-8634-43d993b3cb39"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce0799fd-ab71-423c-b4d2-f59ec86e9b54">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd7e5d8c-60c6-489e-b2db-fdfd9e12bbb1">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca851d37-b452-48d9-ac8d-8c135df6e7d3">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a96db66-689a-493a-a1ce-56abb793a4fa">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f641eb8-f283-4b61-93ca-534217e0e1b0">D<xref linkend="sect_TID_1025" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_882a8f29-a335-41e0-b789-d1f5ef5052ac">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_257c3979-59e3-4b6c-a534-a98ad645cb07">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3fdf735d-a626-4e9e-9a4e-cb147684298b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce04e1fd-571c-4333-8e82-5a078666e7a4">$Findings = D<xref linkend="sect_CID_3671" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7d4d2bd-bf5d-4988-b025-c1bbb7664cd4">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8eb63d9d-48e3-4d12-a226-50588d4e8c99">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8afacd97-cc68-4a83-bc1a-2958843bb966">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_488e8081-bb79-499e-94b9-0822de788316">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c621ad88-296f-4a9f-9480-25a3bbdc66ea">D<xref linkend="sect_TID_3802" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_72391388-9e69-4ca3-a907-6ddfa6bb3828">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_58b6275d-c658-4fd4-8e91-d274ff8bb993">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_49d8b4b1-55ba-4261-8faf-2ba17979cad2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b775751-9934-4e6d-ae29-3a5180be039a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ebde32c-252f-47d7-84fc-7495736b2f9c">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48eefb0a-8040-4ea3-81bb-0ee1b95a707e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf14a3fb-422f-43c1-b106-f97e4f80056f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9294ca6c-8079-4a5b-b27e-29962985316b">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1149bb14-89ec-4c64-a27c-198c090a0343">D<xref linkend="sect_TID_3704" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7bfe97fa-895c-4d04-a13f-07454f7448a6">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ccc9ed25-dbbc-44d3-880b-221be4332679">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2244aee6-ff06-4303-8dd1-e73c4ec4bc57"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3aaf1500-3334-40b0-a1df-1e46abc0bfdb"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_afd0e789-bfd4-437f-be4d-66f116dd72ba">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0ddea5e-1972-4177-a1cb-2ab2b7fcf819">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80c926cc-1920-4821-a538-bf4994fa40a5">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe3ccb49-54bc-4a45-b8bb-2c1606ec6581">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2f14c4c-a286-4333-a6e1-ddc0062e3d41">D<xref linkend="sect_TID_3702" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_472a5273-53b2-462c-bc79-88910a3e5351">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f7025a42-1f02-46e6-b2d2-502ece461875">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3badb228-2f34-46aa-ad2d-affdba24bbff"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7c17134-34e9-4220-b5bf-d13b13740238"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9cc90cac-90c1-4ac1-9aff-bfaa0a6caae4">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1cdca81-7ebf-4f66-b8dc-37a50e724297">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6ea2131-9307-422a-b32e-76e2a2a2c9cf">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d1584dc-2a70-4d03-9080-a4c7a6dfd6db">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00f17412-50f0-4eac-86f4-fc8d5a402d00">D<xref linkend="sect_TID_3708" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9c2846c2-e2e4-4d00-8002-bc25ecbc592b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_26778830-6a26-4c37-be32-8d4882cfb839">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05f9089d-62a4-49f4-a347-47aeaaccd30a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a951587-6229-402e-8274-09b4ad8a497c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7147888-728e-49e2-9e51-4116ca5d356f">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98f0141a-c361-43ac-a9b2-9e2959bf9ce8">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3093513-d75e-4a78-80a9-9577c9b2b7ad">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04b154cb-3e06-4509-ac9d-08437a9f24c9">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6768303c-6e8a-4075-b0fe-28b94497302a">EV <link linkend="DCM_122144" xrefstyle="select: nopage">(122144, DCM, "Quantitative Analysis")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c98dc0f3-9776-42fd-94f7-55aae9fc27f5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ffc7a4d0-617b-4368-8d8b-57988e48c48b">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f81a8b11-c5ab-4e9c-92c9-5ec471a1ec4b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8de99825-9b3e-401f-a31e-b7062b8a41f2"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_313845a4-7a46-427c-b260-4797558fbecf">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_49d3eba1-864c-43d3-a66e-6580f86e8561">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8879a92e-0d24-4fc9-bfed-31ca86c46d80">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38960807-f1ff-446d-9389-c4853cc967ea">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_620ff1f3-1f15-47ed-bd27-734eb4f7e3b1">D<xref linkend="sect_TID_3713" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_39ab1904-2eb4-402c-8724-2bdd6c6b5f75">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dc44c531-8e80-480a-8186-1b2857fe4168">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_072dd96e-0b3b-4bac-99f1-e772558f00bd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4591ca0a-2420-45dd-8d78-327774f84b9c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e01b0a9b-1d04-49c1-94b8-a0453d5683ea">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08557b00-5c31-4939-a16d-76ce84d3965a">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17a8f9ee-872d-4b4a-ab72-441d5651fa03">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bff48c20-d8e2-458f-bcc7-e8c37554f65f">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_558d979e-12f6-4d4f-ba90-d1d578379ff8">D<xref linkend="sect_TID_3714" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dc7cd5e5-c3f6-4a2b-90d2-1da8296b304e">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d7f9a901-52ab-404e-bf01-04a47ff9c578">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d25ba9ad-0e66-4910-b6b5-3d68e9ffbbb0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc56d1d1-862b-4117-a2f1-21ab94dc1f11">One instantiation per reported lead</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_14d62d16-4d70-40c9-ba1c-9d2027d70ce9">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc3ebc53-7522-4071-9397-d404160efbb0">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35971c72-e207-4bf2-8eb9-79b1a703f682">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f09002a1-20c7-4c8e-be64-4cb230c363b4">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a16f568c-7606-49d2-a090-4b99512910c4">D<xref linkend="sect_TID_3717" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2d693518-747b-41b5-a27b-5fbf847ff51f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_50cfc140-4077-407c-8b8e-65fc9ef9f9f6">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_94268905-4de8-4ce4-a863-8f6de3aa6f19"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39a9af56-8fc8-41ca-8718-4a23489cc6b3"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b37b0e33-f334-4329-ae94-b67bf4d5e50c">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_825b02ef-3ed4-403d-93f9-2a18f3ac0b95">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8df4f3b2-21d4-4e67-a779-223c64f12cfa">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37763657-d022-433f-ac31-fffe3987b9ab">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e3f84d1-f5e8-4a17-83b3-85548592c0d1">D<xref linkend="sect_TID_3719" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c6c68006-0642-4849-b49a-83a9e0b9a57e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_35a6f148-8ef3-4662-8035-3f69d80d0b47">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de4b5d63-acd1-4eff-bee9-7d2301211cfe"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f57cd622-7508-4611-99ab-c1784ce5c4bc"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3701" status="3" xml:id="sect_TID_3701">
                <title>Clinical Context, ECG (Retired)</title>
                <para xml:id="para_591d8ecf-b67a-4fe5-8cd7-842ed0657ffe">This Template has been retired (see PS3.16-2009).</para>
            </section>
            <section label="TID 3702" status="3" xml:id="sect_TID_3702">
                <title>Prior ECG Study</title>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_dd4f1971-f89c-487d-9ba7-db1a24556742">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_65fc689d-3439-4648-9382-03c4c17a5450">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_82bbf188-409c-4487-ab3d-4ac8e1b17bf2">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3702" rules="all" xml:id="table_TID_3702">
                    <caption>Prior ECG Study</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_78182ea5-ccd3-40c0-a5df-51a12b78b31c"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3aa3bd25-343c-4171-84a9-32c12df109bf">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_15ad4f41-1a96-4db9-93a0-ea233b49eda4">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_84f7957b-470e-4c0a-9cab-a3ea380bd422">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b84ee4b2-924e-45ba-8542-24d9a03b6464">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0717f3bf-b051-4ac3-b80e-a8a98cc46ff9">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_83d7fbed-cda7-4230-af72-d56bc4752d27">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_612293ed-1067-45da-93b1-e565279bc407">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6d1cff56-1bd2-4dc8-8a64-3add77fda87f">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fab69c93-b322-4b03-a5a3-a81e34ff15b6">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25cf76d3-7b27-43d0-a964-da44125b0e87"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_db87689b-ff10-4086-ae59-1b29e0118509">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8427128-def1-4adc-895f-26e21555415a">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0f1623b-cd80-45ef-8392-c936bf9459c4">EV <link xl:href="http://loinc.org/55114-3/" xl:show="new">(55114-3, LN, "Prior Procedure Descriptions")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3a3e8c06-9d3d-4f9e-8576-bf01fd94430f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c02171cc-e415-4566-adf7-7f4584af6e58">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b3f88d8-b4b2-4861-be84-f4831236a31e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_250ac577-0730-4bb1-80f6-fcbe337454b0"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0c871b8-f248-4b5c-9e27-e171fa746459">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8aa68d80-0de2-41c2-b86d-8dea56f4c9f8">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4fbd0328-303a-4aae-b578-57786c37fb30">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_950133c0-3341-4b3d-afee-7b843551e76e">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36cf2726-7f22-418a-b4ba-36ca1de3012b">EV <link linkend="DCM_122140" xrefstyle="select: nopage">(122140, DCM, "Comparison with Prior Study Done")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_64f01a2d-ac33-47ba-b166-ac63e2613ac8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ee2de721-065c-4879-9112-e288dc4f2aba">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0dfcd063-f196-463e-8c75-ad7682edbeee"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92989f5b-af22-4bdc-a4d7-494e343644b1">D<xref linkend="sect_CID_230" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fbf92ecd-03ec-49e3-82d1-dd048b6c1680">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fba0a650-5269-4817-871e-471600acd8d4">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_45ccd73f-014f-492d-8b28-43c5dcebf820">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e3ab950-6ece-4e5e-9c3d-df44be3b1272">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_34bda65e-86fe-40d9-8cc7-76b9924572f1">EV <link linkend="DCM_122146" xrefstyle="select: nopage">(122146, DCM, "Procedure DateTime")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c6ecea1f-59df-4e92-80cc-9498ccdb7774">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6aa7233c-959f-4977-a0bb-319a270aa789">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93e50a35-8778-4f52-8138-83501ffc8e51"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_debc5a88-5f67-4781-bb78-f88df7f25b4f"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_12f9fbb7-a516-4182-9a29-23d9fb30cf8a">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5bc25ca5-744d-4edf-9914-c6334f173491">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80b22fb0-2cdd-473a-a660-2ed7c423c8bf">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_12cc8288-680c-45f0-8942-b9e37db7c31b">UIDREF</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1caf3ce9-6756-4cac-963c-2be091926fae">EV <link linkend="DCM_121018" xrefstyle="select: nopage">(121018, DCM, "Procedure Study Instance UID")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_270391a8-5bb8-4b9f-9f36-0b6f3679814d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a786f32d-5468-488c-bb1c-6ccb957e1cba">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a10fe36-bc16-4bf7-a0bd-30e2304c90f8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f9d47c9-66bf-495a-a5d5-9cc4368f8473"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4698eac-7878-45b1-a7c8-744f78efc41a">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48a8b40e-b439-4ee0-a9fc-b73813364e55">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b58d3b68-e46e-4993-bfff-ad51b4133e45">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d635ac3d-0d59-43c7-893a-85f2a8a8d946">COMPOSITE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c9bf6d0a-525c-4aa7-ab9d-c674176cd011">EV <link linkend="DCM_122075" xrefstyle="select: nopage">(122075, DCM, "Prior report for current patient")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b9dec6cb-2205-4e1b-abb4-64f41dfdf19f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b1152b15-6300-4294-a2a7-9a174121b3e7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c3eea678-631c-4a65-adf0-52e160c093fd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ebd5da4-83c2-4e2f-a576-af02d0bf048a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d9bfaec-c94a-4fbe-b957-b5bfea524d72">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7755ba56-6054-4fb4-a9a6-e9c002b9a6a3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2ad56a6-ddf1-4eda-bd87-e68641e5a7b5">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_526f46ff-e68a-41bd-ba73-d5a1105003b7">WAVEFORM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a13b42a-593c-4544-97c1-fd68f8d8352f">EV <link linkend="DCM_121112" xrefstyle="select: nopage">(121112, DCM, "Source of Measurement")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3e687e4e-b40e-4449-ae63-5c2c4ef7890a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b8c57132-c86a-48fa-8909-cdbbfc8aad10">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b17a72e-adf0-4487-9f4d-f0823f8f53e7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2fab5d9d-65ac-4039-8adc-d7dcb7d9fb39"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3704" status="3" xml:id="sect_TID_3704">
                <title>Patient Characteristics for ECG</title>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_22b40527-354a-4b03-81e1-7af99f1a0729">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_9801be12-f58e-496d-b288-4f18c1677dee">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_9e1b5f4d-4b97-48d7-aaeb-749b8a76e15b">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3704" rules="all" xml:id="table_TID_3704">
                    <caption>Patient Characteristics for ECG</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_222d644f-6235-40e8-a844-e1c2ec8bd69b"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a83f3433-d896-4ba2-84b1-101557473605">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9f640f5f-616b-4972-98e0-63eadd7e521e">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_30a39578-4da5-475e-a39c-9a363491535e">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7b778a5f-1328-4209-89f4-0e0f4549d1f2">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b62d968d-beff-49b8-885b-988ddf03795e">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_36e5b94c-9f43-475f-b978-c7942efc982b">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_83e14ae5-d2f5-4e1b-b370-0c76f14bfb1c">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_29856510-813b-4821-a328-0731ce671b10">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c25f37d7-2d7f-4ce9-aac1-2a44ebe9478b">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5db4a86-2f68-42d3-bc2c-6f969f9f5b5d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b3b0f15-02db-4dcd-afb3-a89d3883c630"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7188da7f-9da1-4e57-ad28-8458bcf5a112">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93152c1c-3b79-4df3-89bb-e736f7cae6ad">EV <link linkend="DCM_121118" xrefstyle="select: nopage">(121118, DCM, "Patient Characteristics")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_afed8576-ec2f-4d49-9b46-f6f74dc5b447">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_38a32c9a-861b-4941-bfa5-4f1682ed218e">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_efc0d953-685f-4e7c-93ce-37d0a8fcd147"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dddee0cf-992e-472e-831f-9af4f5ecef1d"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1dcdb34a-3e00-47ff-b00f-0659cd5389e9">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36ec041a-313e-4285-8cd0-dcc777fddd1b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fdfd4091-4134-4775-9421-6b61884be192">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37915594-26c5-4015-b83a-8778d254389f">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9eb720ac-02f6-44e8-b887-90d38e328a9e">EV <link linkend="DCM_121033" xrefstyle="select: nopage">(121033, DCM, "Subject Age")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5bc32452-f3a0-4d0c-9d1d-84c4e964f85b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_97a16418-64de-4fcc-8ad0-f2f7b84f3c20">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ecb0785-9e15-40c5-88fe-d576d2649263"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b099d54-0dcd-474d-944f-c439e504511a">UNITS = D<xref linkend="sect_CID_7456" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51cd9cf4-1dba-4b94-b587-12488c51da50">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1506d5b-6a9e-425b-8f10-662fc360a5cf">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_891a31c9-b640-4b23-9fdb-90ca5e222e5e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a54df66-e27b-432c-aa70-bd47a146b724">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f6f7782-d4fc-454f-9fc0-209eefcc0b2f">EV <link linkend="DCM_121032" xrefstyle="select: nopage">(121032, DCM, "Subject Sex")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7d22a709-d688-4fa4-a60d-f92984694d32">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d54270c7-7aa1-4551-9b12-b2f17a618b6b">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dec72e69-d9dc-4edf-b027-af985afebfeb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f9f8796-562d-4a6b-8eee-33f723b99d45">D<xref linkend="sect_CID_7455" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c803c962-1b75-4867-b888-5fc4497d828c">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ef0633a-de6f-4489-b4af-4ddce1c1c3b9">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1054ad32-5d54-4d79-9393-ebca2cf54663">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f53370b-67f5-4b8b-9d35-b8e82c7dfe77">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9aa5696-cdf6-41d4-be3e-672a0aa1fdac">EV <link xl:href="http://loinc.org/8302-2/" xl:show="new">(8302-2, LN, "Patient Height")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_811b3442-9fcf-48b7-bf43-de4e23253c43">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b56cff22-1966-41c4-b65a-7eb68188a6cc">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_47fdb5ec-4339-470a-8378-8f6ea4baa7a1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a7eac4b-bd12-4999-a5e8-c44ac5212556">UNITS = EV (cm, UCUM, "cm")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_373db055-3f1f-43e3-8004-78a7e2b77ab9">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8efde7ea-368f-4b37-bf73-9adff79005d9">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f41af083-62c8-41cd-b2b1-74b0e509bdf7">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6ad5619-8510-472a-a6b1-d464d555b81d">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b40d92bf-2a36-4ff2-9464-357794be09ce">EV <link xl:href="http://loinc.org/29463-7/" xl:show="new">(29463-7, LN, "Patient Weight")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b7d0103-e661-4204-8dc0-4b21e0b87538">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_09cdc0f2-d512-46dc-8d95-826a119c2c82">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0144e402-b163-4028-a794-1f17e58472a1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_690d02d3-6afd-4ab7-90f6-428630ff79b7">UNITS = EV (kg, UCUM, "kg")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05bfed57-dbff-4227-ab9a-d2f63ecc1191">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_742d5357-0ccc-43f0-be78-a70ec061f0f6">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75022a7c-bffa-4c49-84af-7e82b0a7c3a4">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5c2f9d3-74c0-4fac-959b-3402cf63f817">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e96479f7-2894-436a-82a2-b9b92a2f29ca">EV <link xl:href="http://snomed.info/id/271649006" xl:show="new">(271649006, SCT, "Systolic Blood Pressure")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ddd6c75-f39b-4c7c-97dc-c65c95cdd9bb">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_afbb8439-cd48-4896-895c-334e33194ee6">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36e514e0-a773-46e9-ad26-6ffba01b561a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51bf0beb-d513-46e1-9839-ed0c655df8c9">UNITS = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9d14e3c-0c50-4501-8ba1-072d9390fe76">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_20fa6484-b400-4e9c-a67b-3cb092953712">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4e5dad9-e61c-412d-84fe-649758b80b21">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d43ed094-f8c9-4282-a37d-c40c0a1d1811">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc6243df-dfc3-4a55-942a-45e80394fad1">EV <link xl:href="http://snomed.info/id/271650006" xl:show="new">(271650006, SCT, "Diastolic Blood Pressure")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_61335547-928f-4c24-abcf-bd3f61bcff9e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9e1cbfcd-487d-4fd6-ae87-a14ca55102f2">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0f0a879-1373-4509-9040-34fef8834988"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ff40800-078d-45ae-8c39-09846a26c270">UNITS = D<xref linkend="sect_CID_3500" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1e08f1b-f323-4d92-9fb4-144ebe4651c6">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_651d9408-4aa5-4f81-aaf7-b2f43a77184c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3f9176a-95a4-4038-b098-ef256a3ea7bd">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c059538-018d-49a7-bb4a-2aa7007731ff">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5404cd29-3a98-4a96-996a-8f0c8dba472e">EV <link linkend="DCM_109054" xrefstyle="select: nopage">(109054, DCM, "Patient State")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9127a049-eae0-4474-adb0-fea1dd62dd98">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_037877ed-27c4-42b1-a17d-7f6a4f2497fa">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b06e9804-e5bb-47a3-932a-217136875190"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb9b92cf-55ae-4762-8e44-a5da6ac1d2e1">D<xref linkend="sect_CID_3262" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6f58b10-5309-4228-8768-079938960c9b">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c761e43a-0c26-409a-a9a6-49acb26d1c2d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dce6f14f-4910-4aca-8e45-a656b3a635bb">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7485b4e1-98a6-4729-918f-839f45bd4a0d">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9092b429-ed64-4b17-b13f-79b190ac58b9">EV <link xl:href="http://snomed.info/id/441509002" xl:show="new">(441509002, SCT, "Pacemaker in situ")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9b28ec1d-3c4d-45f1-9906-787af12a6a9f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c19af314-dab5-46ba-b4f4-6bc9dd4e156e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1e9e8c1-d576-46f8-b117-e383dc7ca978"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f042eae4-3148-4271-a6e7-20ad6b889680">D<xref linkend="sect_CID_3672" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0c5c20b8-d647-403c-a817-2d9ae3d59369">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_734b5c28-8fb8-4d65-b625-92cebd245abc">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc83cdaf-9ba6-48df-8183-4488b6643f73">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_47ca6fd0-b087-4cf1-8de3-f52d7cd3066e">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25ccb904-f8cd-4c06-9ecb-01f805f894cb">EV <link xl:href="http://snomed.info/id/443325000" xl:show="new">(443325000, SCT, "ICD in situ")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_32d153d9-ecba-4165-b3ca-cc19bb3708f5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7b6a1750-0556-4120-8d41-5b660f7e1f44">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c5b97d1-709c-4693-bf16-8acfb28134f4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d339e72-f0e4-4315-8df3-fc8547e305b1">D<xref linkend="sect_CID_3692" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3708" status="3" xml:id="sect_TID_3708">
                <title>ECG Waveform Information</title>
                <para xml:id="para_ee307dab-ae35-47c9-84d3-38e3b07d748d">The ECG Waveform Information Template provides reference to, and important parameters of, the analyzed waveform.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_48d7e7ba-4c78-4405-be51-fef3a381352b">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f148cf02-ac2d-4a26-90ec-c296dc9c4b6c">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_90587507-6045-4459-9db8-ddb704b2c496">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3708" rules="all" xml:id="table_TID_3708">
                    <caption>ECG Waveform Information</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_856e4831-193b-4e97-bc84-22795e362a96"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85445c3a-3438-4598-8161-dd2f340fc65e">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_25934964-9f77-4ce2-9b8e-02d1fe9ecde5">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f4b0879a-3642-4c40-9221-93e9b722d362">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f4533651-39ed-4571-a8a6-e9e918b06a45">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a4e541f9-8eb3-4aae-a9f8-e7adbd74401d">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f47c444a-9b80-4b13-810b-64b972e61c8d">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dae8af2c-5447-4be4-b2a2-cc2bdb7e4ef5">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_af677f35-2b4b-46b9-b65f-30dfd618b8f5">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_309fa062-d242-48e2-90e2-743e3805f35e">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b7bdcf4-0508-4b74-8656-4f646442a867"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_32f6074e-7999-4960-b84e-19b9115fdae6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_60581b56-5da6-4c6c-a59f-1c0ece2a9aba">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_12271c08-b82b-46c6-98b0-add347197112">EV <link xl:href="http://loinc.org/55111-9/" xl:show="new">(55111-9, LN, "Current Procedure Descriptions")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dc0096d1-5b9a-4df0-b60e-351798a5bbad">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f4132f7c-260f-4851-a7c2-3ab1aceed5dd">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a62df6f5-e9ae-44fa-8c37-55b26980071c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82290b7f-40a6-42a7-93d9-b4efaec6939c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa825ced-8b32-4ab4-9a02-228fdaeaec2d">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8fd1bf24-ab81-4968-8123-40af32dc8c48">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26061c8a-f7c3-485a-b549-45f72991eb8b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c127040b-5dc9-4129-9268-62f8b954e027">WAVEFORM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd273cb5-24ba-4b80-9383-b4498008eb9e">EV <link linkend="DCM_121112" xrefstyle="select: nopage">(121112, DCM, "Source of Measurement")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ef7ffede-89c7-49d1-9510-83b4771179d8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_13547f2c-c37f-4e92-9a74-c19b458c3ed5">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_380764a8-57fe-40f3-90bb-f10f8a6d740d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b389ccdf-3440-426d-b50f-1b2212867006"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f7ca065d-eca7-457d-a756-df4e6170b556">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d642093d-70a7-417f-b5fe-c1d56cdc40e5">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ea36603-37cd-495b-bc1d-d7e423037347">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ce60028-2f22-402f-bea7-324ecfc1b415">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8bb2023-1482-4d9c-9d17-23c677549a3e">EV (10:11345, MDC, "Lead System")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7240d47-a81c-4745-a551-77921a8bfba3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_56868b50-ebb5-4e28-be4a-7ada3241a2fd">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a446e99d-7656-4642-b3a2-8969547d566a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_054fd1bc-da8a-4f24-84c8-2933a0b76696">D<xref linkend="sect_CID_3263" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39300c57-d0c7-4e1d-9adf-9e2ba8c7e353">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ea74c9c-82c8-4c8a-9181-39c6d9e11dd6">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b34ffc7d-d139-4155-9b8f-68eb372cefe5">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb90220e-f411-4889-b537-933310121f83">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9bd76c16-faa3-4106-9d67-a0e0ee47f2b2">EV <link linkend="DCM_122142" xrefstyle="select: nopage">(122142, DCM, "Acquisition Device Type")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b3fa53da-f50f-4d13-bf02-71bf2bfd83d0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4fba268f-483c-429a-a0a1-cf5c9b82a12b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46c109a9-d437-49c4-9a12-54fff13469df"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_154a0e26-cbbe-4866-8b49-b36d1858ab6e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22f1fe30-b39c-49ed-9373-a76d1a1f1fa9">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_66ef3d72-8a35-444a-ad2a-c7dd8dd8e1a6">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2183c3af-d6cb-40ae-b2d5-31f962192177">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ec22a9c-543a-4bfd-871f-04bdd0a3ec15">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_533a6acc-2b8f-4b04-9cb0-943f953ec359">EV <link linkend="DCM_121122" xrefstyle="select: nopage">(121122, DCM, "Equipment Identification")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_51baed20-4d36-454f-8894-50420d1d6905">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3f69c12e-92cd-48ee-9286-97a0028296ad">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b768dff5-3c88-43e0-b049-a9f9d85ebdcc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_774c9cf0-c369-4f12-86f4-0cdfbedbbc1c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29195661-a182-4e3d-82ac-02e2a295ea55">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86cdc1b6-f4d4-4265-822e-800ca1642055">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8c039ae-75ac-4dfc-881a-a3dd06ce329c">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79774f24-e153-4241-b999-0182da6c304d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd241a5d-dcdb-406b-8f1a-41ee53573061">D<xref linkend="sect_TID_1003" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3098a31a-e791-43b6-8466-891607f7191d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f9f8161-2f64-4e8e-8743-52168efc0765">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_49f8c772-a753-48e9-9788-3d7aff5d1b1f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3cb095cb-da7a-42a4-a4c8-a0373123192c">Person performing the ECG acquisition</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_322ca33e-2b72-4460-9d66-0fa6c59c3b56">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_94dbbeb1-a3a1-41cd-89cc-a1bd56ab3ad7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b74fedc-7335-43d3-ae9b-a952773073a5">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fcadaa2b-37be-45d1-8202-035084cba531">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2aa83777-cd86-440e-bf29-b5128c944f55">EV <link linkend="DCM_121121" xrefstyle="select: nopage">(121121, DCM, "Room Identification")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_92f25ef8-26d1-45ce-b217-48df38a7a241">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a4182a0-b635-4c7a-a9ca-3149200fb7b0">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2fff433-16e7-4734-a248-d486aa3f97fc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b8999b50-ec44-41b9-94dd-08420de9c63c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_509fe628-d71b-440b-b928-a92976c698af">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9405492b-13e7-43c8-af0c-298cea1ae901">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58e5019a-d081-40ff-9d1f-64a46f71db94">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_40ee6fa3-af03-4b81-b5e0-ec8fb9ac8fe0">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc0da308-da0f-4609-9404-509e8ddf0c95">EV <link linkend="DCM_122146" xrefstyle="select: nopage">(122146, DCM, "Procedure DateTime")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e81190cc-3e56-4e59-8312-124d58585a78">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c53fe221-fa13-423e-bd19-6925eba79d3b">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5bf886e8-dd89-41f9-8a2a-f8c5987f774f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_76d138d4-c961-4bcc-bb54-dfa7251773af"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d9bdf84-12e9-4742-acea-602ffbfb96bb">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84dd28d3-67df-4b99-8a80-6a925cca4b79">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84d30175-b7e0-4e22-b49b-b43e91a852ab">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1de65cf5-bee1-44bf-b425-42b32643e9c3">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad5ef414-3904-47e8-b96a-ec13c052603a">D<xref linkend="sect_CID_3690" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3ee536bf-66d7-4f2e-b066-f3b0fa9cdbfd">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f3142da1-0dd0-40dd-9df7-9b382c17f3fc">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5a3e904-13a8-49ed-b3a1-459aa8680580"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_344574af-64f9-4639-9de5-fb52c2e21eb3"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f51a16f0-d3ef-4608-aa5e-a179f5ad72ce">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52490206-ec86-4a9d-802d-7ed0dd9c26b1">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d37e731e-a67b-47fa-bad3-6815915e32cf">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff21a238-0d2a-4b2d-a3d8-08dd54fc174c">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f533bf61-1ac3-4076-9a01-462cc577d1fe">D<xref linkend="sect_CID_3691" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ca491d0-dfe2-4f08-b7af-9e15cc51cbca">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d897fb3b-e39b-49d6-93ab-df1b51139e69">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_78c2a2c5-fad4-4a46-8250-5cc893374505"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d4de5196-ba95-4878-89a9-4a1b22222219"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96fc41f2-5e93-493c-983a-344f56a1c9f5">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b7e37bc-fdb2-457c-bad5-3154daa1900b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de6c5e30-6a81-470c-87c8-1ce0cc2da03b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ac2cd82-8470-4e73-a4ae-4536f7d951aa">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d312e3a-631d-4755-b1ef-0e66e9737d25">D<xref linkend="sect_TID_4019" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dc3fc489-2382-4e9e-acab-0b6b444f7b85">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cc70489b-a057-44b7-bf17-d8d4ddb0f19f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_023485ae-e70e-4902-a1de-0e2249897631"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9cd63615-c23d-4004-ad3f-334ba98d21d1"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3713" status="3" xml:id="sect_TID_3713">
                <title>ECG Global Measurements</title>
                <para xml:id="para_39d94f3f-fed5-4166-ab40-f25007cffcdb">The ECG Global Measurements Template provides a structure for measurements calculated across the ECG waveform as a whole (multiple leads).</para>
                <para xml:id="para_6409a827-e5c9-41d5-9d8f-2c6ee159a3a5">As an Extensible Template, applications may include any ECG global measurements, such as angles of the electrical vector of various ECG waves. The recommended vocabulary for such concepts is ISO/IEEE 11073-10102.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_1f95ff63-1901-4300-b042-11172eefbe58">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_79981eab-d164-47e8-b63e-eea33583e9d5">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_47e11eb2-b83d-439b-bcb9-d7c0118d3bad">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3713" rules="all" xml:id="table_TID_3713">
                    <caption>ECG Global Measurements</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3062111e-58bf-414d-bce5-e373a89a2c5d"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f4ce2415-fd22-4458-b79b-a0b7208c711b">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6189f6c6-88c8-4dc3-b51e-4023c44c7614">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7365f264-9f07-42bb-98a6-6d296cede1e5">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3860c3be-7491-4b02-b8bf-24e884af9e98">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3c090d06-46b3-41e5-9e7d-5757e4d087ba">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_90ac4d0f-e0ec-41d9-8af7-9b94814113c6">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_adea20d0-4c2b-4b8e-b3fd-5c4b6cfe963c">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ef8e515d-4cf4-4bcc-8c4a-a716a6bad508">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17658ebc-d900-43b3-940a-25e688c0a8b5">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3665f7f-7275-4de7-89ea-c7e30ce2a3e2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff98a01a-9483-48e2-aff1-c0cc97cea0be"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c01bd48-9fab-4dfe-bb85-796f305a4a0f">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29b46064-5402-4629-aa1f-26edcaeaf967">EV <link linkend="DCM_122158" xrefstyle="select: nopage">(122158, DCM, "ECG Global Measurements")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bfdb0c26-6469-4860-a294-502417e1986a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ee9382cb-0b99-4db0-86a9-c6c7f79817a5">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7eb7fba7-b821-443b-a752-98e0c559e144"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e333900f-3ec7-4787-93f7-e968744f1da0"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85e77474-6171-4095-bc7a-1c1254f355f3">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_270585eb-a221-4e7d-a32c-bd870becb4e7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c2b75eed-09ed-41ff-85c5-709a0523e607">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_332d9f82-690c-4586-bf78-0351472163da">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4ac3d23-5411-4f47-83ca-7c37c611845c">D<xref linkend="sect_TID_3715" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8572ce55-1ee0-43bf-ae72-b59546af1bc1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_75fab0a6-6ab5-4ebe-a1ca-b554d18ea8e6">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a57b9dc7-ffae-437e-8c52-ab68d26a816c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b4c77e7-2bbc-4b8c-9e84-c27cf05d882f"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_efbb1428-627f-4ff7-9768-86ff03adce4b">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_589bc9b3-e215-4a05-8335-589b7325cc73">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30141c4f-0ba0-4f45-a9e0-68420f8866bc">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3a3b97a-c622-4885-b9cc-da989226fb6f">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3a6adf7-7989-4566-83f8-8a80d1438d39">DT (2:16020, MDC, "Atrial Heart Rate")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3cc9d10c-53ab-4814-b333-f8ffe025aae0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_af0ca40d-831b-42e7-bfa3-fcfd63d68b7a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69a8d260-f8df-4398-a323-c0ff7e1aa414"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_23c497ee-3573-43ba-89d1-4c798b268f65">UNITS = EV ({H.B.}/min, UCUM, "BPM")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a378791b-7536-475c-a5c2-8da1276a9be8">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fed3d146-a7b4-47ec-bd84-6758fec2b03c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8cf06938-82ae-4426-b984-d6850141a13c">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3132a8eb-13dc-4da7-b40e-008655d036cc">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0754519f-5665-4769-a235-2eb47117f46f">DT (2:16016, MDC, "Ventricular Heart Rate")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c2bcb270-fd73-48e3-87a5-25d173ff4640">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7dbc22e0-755b-4957-9964-b31e5dbcef67">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_01061708-ed10-4696-99e6-9d56e10d01f1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9636d493-ec17-4508-91e7-cdfead776373">UNITS = EV ({H.B.}/min, UCUM, "BPM")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_49480ed7-d99f-40a1-a901-5e3a7ca3cbc5">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b6e1c7a-ef64-4b94-8172-cb93f36e77b3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c728341-c7ab-4c2c-ac45-6b16e9292970">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7b38eeb-93a6-444e-952c-5a8309eba398">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9452e600-a717-480b-ab62-15866270cb9a">DT (2:16160, MDC, "QT interval global")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c6ebb2b8-cc4c-48ea-b43f-dab1729959c1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1124b43b-4e58-4a87-9d12-f7e0a6bf4f5a">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d37d933-d77d-42aa-a5df-1f1f0645aba2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5fc645b-2cda-4b7e-8181-445e7ea90cfc">UNITS = EV (ms, UCUM, "ms")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9bb9b12e-a0b2-4dd2-9c26-774c6cc567d4">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_794cff8d-c497-47e7-bd26-3897408360b2">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e70f2d0-e71c-42b8-b2ee-863a1bc475af">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc62daac-79e1-460f-b03b-61c3571dd898">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59fd7ca7-49c4-45e5-a813-098ab828c08a">DT (2:15876, MDC, "QTc interval global")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e0e6d9ad-7640-48b9-aa35-b124b717856b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_47e00ceb-2af0-410a-836c-8c26383a3916">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc9832f4-5b2c-4223-8037-6b9d941d64f2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_60d23945-8802-4895-98c2-830b05adda8b">UNITS = EV (ms, UCUM, "ms")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f5f6b99-5e34-41a7-b00c-4f3de55efc20">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f44932d4-b01c-48fd-b88a-9d171a4988e6">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39ea4c96-b05e-4a14-9b81-0d8ece6676a1">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cbf68f4d-3e3d-475d-b2f6-d70deb63f0e7">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_68f6fc03-82d4-4b38-b6a2-78d7e2cde18c">DT <link linkend="DCM_111001" xrefstyle="select: nopage">(111001, DCM, "Algorithm Name")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a7585289-33be-41e8-8c18-020e9a1c05e2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b8438d40-b335-4ce3-bc57-6db413bddc15">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac5ac1a4-0329-459c-87ad-ceaaed2ade4d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd9968e4-0bff-4aa9-8602-3acb7102d527">D<xref linkend="sect_CID_3678" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d4ca3c9-a4f0-40ea-bed6-30676cc62b5a">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0bb0632-4451-416e-ad32-6ba11b69185e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b67a03f-af58-4650-aa16-0ff88cddcdd6">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a3096e4-f834-44d8-b02b-e771c0190933">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d1c9734-66f9-4cd2-887b-035ffd071e1d">DT (2:15872, MDC, "PR interval global")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0a80ad4f-ea74-4e7f-8d62-6b2cce4d1e8c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ce08ea32-365a-40dd-b7ec-d0e01bb31644">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2858d96d-bbe8-486a-9d08-a27a0debc1a9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5250ea22-034d-491f-953a-c002d97aa8d2">UNITS = EV (ms, UCUM, "ms")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7343cc3-27cd-4b00-b82e-0d320da0b20c">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51dfd869-8bb2-4af7-8382-3dea245d7666">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_642285e4-7967-403f-a5ad-462398df292b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e99bf4f-5ce6-4f0a-ad4b-9115e30067d8">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05246ed8-3d45-4dc2-aacc-3b2a4852df6d">DT (2:16156, MDC, "QRS duration global")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ee28aead-3e17-4076-8351-49bd0aaa35ae">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c0a9ed1b-7b4c-4819-a8f5-5a3c0447b8bb">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_94b7165e-8dcc-42b2-8f0e-1c3ee161dd57"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11abb3a9-2928-4425-8f72-b82b1d6ed954">UNITS = EV (ms, UCUM, "ms")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7dc65e69-4619-4289-b81f-e63ace18946c">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a6f3abb-3a4b-40b0-a376-73395abdf023">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81c3e02c-e5db-4a70-b3f0-034c536f0b9e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc6bd9ea-62bd-4002-a721-a23023ae14dc">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e04f1ec-eb71-485b-b26f-ea1d21c1f3d1">DT (2:16168, MDC, "RR interval global")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_48affd6c-0f0c-4ee4-aa9e-a2e5aa4754a9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c533677b-f2a7-4822-bb4c-1fac4f5b4a29">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c66a84d2-c081-4262-9e86-36ca09b0b55e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7bb93b6-e084-49ef-945a-46d59544f42e">UNITS = EV (ms, UCUM, "ms")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f24f47ce-9dc5-4165-88d5-1b5da131cac4">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a192a4f-e8fb-4baf-89ee-ef84adbd92c7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da8b60c1-c142-4ee5-a847-517768f06c14">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e63f5f4f-8943-4671-a4f8-5db1b9f649a4">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df5b6e22-6b25-4356-b1bd-f19fb8da95d7">D<xref linkend="sect_CID_3689" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ffc9a3d4-a30a-4667-8637-9b2a0b4ca3f3">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_78cee8b8-38ff-44ec-8aeb-7e0289257baa">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0524df6c-7537-47fa-b8af-5292f78fcb3a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f99adfdc-5425-46c8-84d3-ec7240afaf3b">UNITS = EV (ms, UCUM, "ms")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b07449b7-71c3-4f55-a0b1-9c7bb52772c4">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96897c5f-8989-4252-a65f-52e030c5a893">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c66b5c7-a73a-4abc-912e-1e1b004d4db7">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d24d515c-e5bf-47a4-b67c-de1f67ebd7ae">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_578cf798-e014-447d-8470-904a4fd94d0a">D<xref linkend="sect_CID_3229" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e85c2ca5-dbfd-49df-924a-3bb94c10811b">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f5e94acd-aee2-4e14-a8b6-6a360238450b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f35f8fb-274f-49ce-a116-f99b8472ef2d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e1abfb4d-83bb-4291-ae40-bf0d7accdc75">UNITS = EV (deg, UCUM, "deg")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e145d676-9384-484d-a616-4ff8546d1000">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d2adab91-7830-496c-b51e-7d634ce67c62">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3175172-e206-479e-8e04-26682b3548de">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f65ded68-9972-4278-ac2a-53297ccec585">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80f82e91-d1cd-4a30-bbff-586c2d7895d2">DT (2:16032, MDC, "Count of all beats")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c10ab2d7-8364-4059-a37f-e0ac684e9cb4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bebb3828-a394-4c9c-afc3-9410810b1555">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35ccde11-34f7-4603-a40b-a447e9effa28"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61edd5cf-2dca-4773-92ae-990e1aecfa9f">UNITS = EV ({beats}, UCUM, "beats")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_23f02421-ef43-45be-8ab1-d7cd3274700d">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f722c6b4-3c27-427e-aa61-5435792ff509">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b515f562-a026-48b6-8e6c-5bbab06eb772">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8443e6ae-99f7-4efe-88ee-124482811ba1">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7336600a-c2b4-4d70-91d7-7d6fc1d77534">DT <link linkend="DCM_122707" xrefstyle="select: nopage">(122707, DCM, "Number of Ectopic Beats")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5e4a34ab-06aa-45b9-ab85-4e1121a0571a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d1c67ae7-f427-4c70-a4c2-8e76e4ef4987">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e9e8d22-616a-41d9-80b2-a3ee490d697d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9812be85-ef3a-4936-840b-7528ee91dfe4">UNITS = EV ({beats}, UCUM, "beats")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8374bec3-ce92-4e2e-8de9-537b3ac8d323">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cbb27c89-fd73-450c-a558-621cae983347">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0dcc7f4c-7117-4b41-885e-7099acdf5981">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a1fad0e-966e-46e5-8adc-476d3079aaeb">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb220f74-9bc8-4ad4-811f-b19dbe8415bf">EV <link xl:href="http://snomed.info/id/116676008" xl:show="new">(116676008, SCT, "Associated Morphology")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a10b5208-a6e7-4e8f-b972-e32d57280123">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc2a9179-9af9-4ebb-b541-c16635f4fede">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ccd6ffe-9a62-4640-b51d-8bdf99cbd163"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_20705eb6-6a40-4079-a8e7-82e59e4788e0">B<xref linkend="sect_CID_3234" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3714" status="3" xml:id="sect_TID_3714">
                <title>ECG Lead Measurements</title>
                <para xml:id="para_4f2e4fe2-aca2-4e85-bfcf-2d2680bc1f15">The ECG Lead Measurements Template provides a structure for measurements calculated on individual ECG leads.</para>
                <para xml:id="para_bb11f074-ae52-49d8-bc7e-4092d7a426b8">As an Extensible Template, applications may include any ECG per lead measurements, such as integrals over time of various ECG wave voltages. The recommended vocabulary for such concepts is ISO/IEEE 11073-10102.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_5c92b30d-2412-4707-8df5-18f0a320fb4e">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4f29644e-c4fa-4e9f-be27-c1f8ab25b941">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_82611fae-816d-486f-a9a5-77eed2b476da">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3714" rules="all" xml:id="table_TID_3714">
                    <caption>ECG Lead Measurements</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ff2819f5-7a0c-40d7-94ed-db4f10df4039"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_61068076-b927-46bd-9b89-1a7d332c85ae">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8c5dd324-89a2-439e-bd74-10e7e035f251">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_36af02bf-005b-4281-99b4-bd56fb3ff6d9">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_82f1d1f0-ea92-49df-82b1-574aabe4a633">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_069ecd26-4569-46ac-a554-1894b73075ef">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8e0d314f-3bb6-47cc-8ad0-e8336fee118c">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_37978a51-30ca-4c00-b412-9fbe93f4e04a">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b56adcb4-17aa-4e97-ad30-17c740674a44">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2c15c55-fc78-41f5-a17a-82b3ad38a32e">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5272a4d-26b4-4205-87b1-d871ee44bd35"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b83811fe-d4fa-435b-8be3-2e608695778c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b22e192-eb4b-4253-935b-df742b3fbb31">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_117db6d4-bb18-45d7-990e-bab869de1015">EV <link linkend="DCM_122159" xrefstyle="select: nopage">(122159, DCM, "ECG Lead Measurements")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d5e2850d-117f-4ca0-ba6c-58d9a8ff620b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f47f7dbe-18d3-44f3-8017-a12018d29fce">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b2758bf-8d3f-48f5-a9d8-06213edf18f6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4c332ab-136f-478a-8d52-8e4ac109aa0e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f8e6730-77d6-49c1-874b-6ce181974bc1">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b176185-3f47-4246-bff6-52b385a56f36">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e13a828-ae58-4da1-921c-92e4cf1774de">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ba65c93-01d9-4ace-911a-7a65be485b9b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97f9ba0e-60c2-4e1d-bdc5-0100d266aca2">EV <link linkend="DCM_122148" xrefstyle="select: nopage">(122148, DCM, "Lead ID")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_46c7cabc-8f47-4137-80c4-8e9f59bc4808">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_31cbd5cc-1755-4fc2-9f46-cbe95eba73ad">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2593efe4-ade4-41bb-8d55-75e0d5eef0b1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8e03378-da50-4967-8f3b-dc757fb6a368">B<xref linkend="sect_CID_3001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4df01d4f-bf8a-4d56-90bd-4fc716693d21">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd9d6c6b-9d5f-4d50-8e01-3117409e167a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_71f067cc-eebe-4e77-9dd7-de12f5975eb8">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff519ed2-9339-4e91-be3c-5196ec0d87f6">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_71b7c82b-2c1e-4180-9e26-531b43a30e9a">D<xref linkend="sect_TID_3715" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3a3d1a6d-e96b-44df-a836-629b2d683371">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_600cedf3-aa2f-4961-8106-133f0f2c7647">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35d8752f-afa2-411d-8896-a17825ea1a17"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9737dcd-b344-4272-8818-10667b977168"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d87c2a7-f67f-4410-9350-ec5e1ad81642">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_784f9c9e-b29f-4b8a-bc27-3c6d57f51727">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2d8ad47c-57cb-4477-8fc3-92ee6519d61c">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bdb64c7e-37bd-4a56-9417-b620d818bdbc">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_32c23f41-910b-41e3-ad6c-4c61e5b1aeab">D<xref linkend="sect_CID_3687" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_81ea0e87-8889-463d-aa7a-2acb7f4d01ed">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_59459331-8774-4c56-8395-58ea49de8be5">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eda2d895-8886-42dd-902d-f1f5d7b3464f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85b55e5f-88c8-45ec-af84-d138b2b03695">UNITS = EV (ms, UCUM, "ms")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4dc55c66-dd3a-48f9-b989-7274f727a876">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2badaeea-8eb3-4bc9-a6ea-7d0aaf69b3e5">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1bf80c42-3824-40b0-85a6-01346cf29478">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4c19a5d-60ae-4289-a7ae-f8d768c705be">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a24dba3-eafa-4700-ae51-bedb43f9408f">D<xref linkend="sect_CID_3688" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_459c0700-fb76-43e1-bf8c-b1ca80474d21">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_856aa0c2-99de-4f32-afa1-6c457e376c18">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd28b918-5519-4899-a760-e0ede903fad4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c6ecc1e2-5d8a-44bb-9257-4c764d3dea13">UNITS = EV (mV, UCUM, "mV")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d942161-8649-401e-b3a4-dcb1ba0b9537">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2aff22c0-5ff7-47da-84ee-ca725943b220">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b3ca392-3e87-41e3-b1a3-64f294e2b569">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea8072b0-5c96-4580-8762-8fa1ab597028">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d2074618-693b-4ca7-bd41-33724e7350bf">EV <link xl:href="http://snomed.info/id/365416000" xl:show="new">(365416000, SCT, "ST Segment Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5966f136-7569-46ee-8b81-17d53334f87a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_95f067ec-ae0b-49d5-aa92-930ec32052ed">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57d35973-79d6-4190-adf7-6f05522884ec"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8eddb030-5185-4770-8dff-1dc3e831eac2">D<xref linkend="sect_CID_3233" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_826789a9-1e4c-43ec-b257-a5db394e3b72">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d577402-87a3-4759-8c9d-883d049558dd">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5c6b6ff-3968-45f8-aa74-96c2c375fbfc">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ebdef37-5966-4dae-915c-e522c8b7ec82">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80033995-6b85-400c-a766-b2646cc59473">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ed014743-68f1-447e-99bd-fb5306a83d98">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7857aa12-1a68-4896-8b40-42c66b53c40d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58bb9d05-8c74-479b-869a-698689932842"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70b53cd5-98fa-40e9-8e59-980062de344e">D<xref linkend="sect_CID_3680" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3715" status="3" xml:id="sect_TID_3715">
                <title>ECG Measurement Source</title>
                <para xml:id="para_fa22bf84-aba3-482f-90d4-1911604a9082">The ECG Measurement Source Template provides a structure for identifying the particular cardiac cycle, or beat, in an analyzed ECG waveform used for the measurement group for which this Template provides Observation Context. The cardiac cycle is identified by beat number, and optionally by specific temporal coordinates within a DICOM ECG Waveform SOP Instance.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_6a5a838a-8eb8-4c26-8f86-1494f81f342e">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_27cf8732-7bac-4df2-bc34-a8bb9e373336">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_8bd8e9f3-91c8-4714-ae3a-8e9988de0411">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3715" rules="all" xml:id="table_TID_3715">
                    <caption>ECG Measurement Source</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_07000adf-a4db-4c1c-897a-f6f3e1923ec9"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8889afe1-c26e-4f6d-a80e-9bc30f06a04e">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cef1b1c5-be99-4cb5-b8c0-7a4c9bb58517">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ab958537-849c-443f-bf9a-dd57f968f2ae">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a40241f5-2111-4641-af7b-668aeb4d8365">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_96b17777-bac2-4981-8e0c-7f7a2f694376">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_42cbf68d-964e-451d-ab90-21c98a10fe06">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d7abe762-b18c-4c21-b748-1f58191b519b">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0737e2aa-00c5-49a9-9d50-39462eb7075a">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4500c2f3-e00c-49e6-9296-ff894bf06a07">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7bee643c-e242-43c9-a867-4254834ec4e7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_66153899-00d1-4417-86d4-63b922e2c97f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9e10978-c1b4-4d1c-98a6-5b286f0850cc">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1203675-4bab-43f4-abfe-d08eb26dd8ac">EV <link linkend="DCM_122149" xrefstyle="select: nopage">(122149, DCM, "Beat Number")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e37a8d52-1ae7-403a-85f4-5a1495750380">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c4aa9632-ed6e-40e7-88d6-f8242848ebbd">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eef50b76-6086-441b-bd2b-fd2f2e00ff58"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_77ce221d-5ed7-4d64-a49b-aa9c12fbd1cf">Up to three numeric characters</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d1c51ed-4b74-45af-8583-9f640d4f76b6">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04c05e81-ec94-4092-a4b8-1484edc0f532"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f75cf47-ed94-474b-a0ea-17ab069a2d88"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6919b365-3c26-4f5c-a39f-7a15f08737eb">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_529adeaf-b930-4aad-9e5d-3121cb8cce84">EV <link xl:href="http://snomed.info/id/370129005" xl:show="new">(370129005, SCT, "Measurement Method")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85482a4f-6777-4fc4-a775-f5b1f6542003">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2b28fdcc-e33e-48f9-8138-efd4f5f1f597">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb05b661-0c58-4abf-b059-4ccce1cbf129"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2639eb3b-9c47-41af-b8e2-de9543091f55">D<xref linkend="sect_CID_3676" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c159dbc5-0e01-489a-8557-0362edeba7cb">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c57dfc39-8f6e-48d6-aeef-d9d2d4857f3a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_364f1e40-9bc4-4701-b12d-03fd939e4daa"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ffa800a8-6ad7-49ac-9bf7-b3d0b9de7207">TCOORD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_32b79ac4-5c2d-47e1-a7bf-c03b7b5c5ba1">EV <link linkend="DCM_121112" xrefstyle="select: nopage">(121112, DCM, "Source of Measurement")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7a14601b-f1fb-47e9-8c94-c9c8a33dc8aa">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_26bbea1f-6f8b-4b24-b7fb-5581c1cad09d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_efcf1d6e-23ef-4339-8e89-6fdc0d005a5d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1adbdf29-8bc9-47a7-96b7-c43b06cbd256"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67e6e7c5-e7f8-4d49-a826-63ac1a34d605">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f16e4387-4278-4e05-8bfb-c871b6fe7dda">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1f81dd77-266c-47c9-a3db-e5f160ef2853">SELECTED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57dbe122-2353-4f66-9a6a-28b6c73bb907">WAVEFORM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3177f6f8-c664-4cf8-9396-aa1f25f08fd1"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f72576b9-5fae-4b65-bd18-8f67841556aa">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f2291232-baf3-42f5-8996-a94937147aaa">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_18562926-1436-4d44-95b4-7cf0bfa5effc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24442815-9ae6-482f-83d4-3ab4bceed3ba"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_dfee5edc-eec2-4471-9048-e77cd0ef1b52">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left">
                                <para xml:id="para_dfb5bb45-cbf4-4128-abdc-aee6bbe40da0">Row 1</para>
                            </td>
                            <td align="left">
                                <para xml:id="para_058b9f99-de19-4c43-9b21-1b6843ba041c">Beat Number is specified as a numeric text string, and shall be treated as the ordinal of the beat (cardiac cycle) within the waveform acquisition for this lead that was analyzed for the measurements in this container (i.e., "1" for the first beat, "2" for the second, etc.). If absent, the measurements may have been made by a technique across multiple cycles as specified in Row 2 Measurement Method.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left">
                                <para xml:id="para_1ccba357-8418-4b08-a263-32c0a4be5abc">Rows 3, 4</para>
                            </td>
                            <td align="left">
                                <para xml:id="para_d08490ea-80ce-4b01-a8c8-defd615395ac">Source of measurement identify the specific channel and time period within a DICOM ECG Waveform SOP Instance that was analyzed for the measurements in this container.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3717" status="3" xml:id="sect_TID_3717">
                <title>ECG Qualitative Analysis</title>
                <para xml:id="para_138d1324-3f58-4c50-8a93-f85cd9b69773">The ECG Qualitative Analysis Template allows a free text qualitative interpretation of the analyzed ECG, as well as a structure for a coded analysis.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_cd78c90c-c91b-4066-8b0d-98660f3dd201">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_2a1e2ccb-009f-481d-98f1-06c42873c454">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_0b82191c-ceb2-43ca-9089-45b911d1f283">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3717" rules="all" xml:id="table_TID_3717">
                    <caption>Qualitative Analysis, ECG</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_81b08f76-08b3-46aa-80e5-7acc66d9137b"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69cb98c1-0c71-42cc-b1f4-2c07c99ed484">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c5826424-1b86-44f9-8e27-203881de7402">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c4e6f7ee-c2dd-4a90-914c-a41546f68353">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_052fdf3d-e020-458b-8f30-ef48a9e025b5">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f9a370bf-7c34-4a3f-87f3-097914e825ee">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a346cac6-b3ee-4563-a378-aa629c580e79">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c3f56c00-c863-475f-acaf-db1f1c519b9e">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8afdb33f-bb77-405e-8d8e-e6925e18f033">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e319759-b2c7-4084-96df-3dffc8fe59b2">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b07bec4b-8307-4aa7-a5c6-72535faf1c20"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ead4ca37-ab72-4bb6-b09f-3fefa01e5a4f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_edf00c03-bca9-4a03-9bec-2a7b9dc5e2d0">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9cd15d21-579c-4225-83b0-4ed2e2ac7de2">EV <link linkend="DCM_122145" xrefstyle="select: nopage">(122145, DCM, "Qualitative Analysis")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_abcec335-eda4-4167-8146-8acd097c4492">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_43122d94-a91e-4256-b8e1-b8f7daaae0a9">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c33c1b6-dda4-4658-bd86-954622b960c3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c59d47cb-65cf-4ef3-a650-d8a8e677b319"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c86d845e-f4ae-4c0e-8664-8839303bfa13">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d6fa91fb-7f0d-4da7-8211-51cd67e93330">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8627d6c6-e650-4f7d-b978-c9d9ca76a226">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c39992e4-e5f4-42bb-960c-29c4327cc1a0">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a8b311a-d97e-4331-a558-bc69b7748c00">EV <link xl:href="http://snomed.info/id/271921002" xl:show="new">(271921002, SCT, "ECG Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0015443f-ae14-4400-882a-82a53d833ef5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0b227c5a-72b5-4a82-bebe-cd10889f0cdc">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83b404e5-6868-44c2-b62e-be719b52c394">At least one of Rows 2 and 3 shall be present</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f235c0d9-fb3e-4002-b956-e8fa5ceb59eb"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5aa87076-6e7b-4e30-bffe-b41c9cff616f">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b9e4048-10aa-4dab-b560-88b02b6166f3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_44989f9d-8c94-41e3-914b-b0215c9529f0">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fbb4610d-fdf4-4a4d-b6ea-089265c3c0f9">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff156abc-8568-42b5-b05b-d89580b7f5fd">EV <link xl:href="http://snomed.info/id/271921002" xl:show="new">(271921002, SCT, "ECG Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e542fc02-b70f-465c-874f-d9eb9047b272">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8e4ebc65-f110-4587-abf8-0db78b05e78f">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3416abf4-90a6-4d85-b6ba-a04bcc4b9667">At least one of Rows 2 and 3 shall be present</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ce1d708-c4ee-469f-86f2-32d80ded11c1">B<xref linkend="sect_CID_3230" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1600d1a3-739c-48a3-bb7b-b424a089aea6">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac22fa69-d367-4233-80db-d74b9f1bde50">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50c276a9-86c6-4d4a-91fd-e0f83f2af8ad">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4d6f5e2-f0ba-4964-87fa-fabffe2f3daf">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11a3fe17-052a-431a-a1d7-2344ab9d61af">EV <link linkend="DCM_121051" xrefstyle="select: nopage">(121051, DCM, "Equivalent Meaning of Value")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f92bb5f3-10d5-4a8d-ad20-0409aa072df1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aad92af6-7d09-448f-8838-4ab79c7c9a2f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_034a25d7-5c6c-4069-b9a4-025470a8ad9e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b2656b9-9df3-42e5-b7a4-fc2e4e36c8cf"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c2eddf5-a0f7-4f5d-838f-ad37be603a84">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5bed64ee-2aad-44a8-9058-ca2cf2e3c602">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_833581f2-1d08-422a-b727-ee4aa3813b21">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b01d7f8-e712-47c6-ba6c-5b1f8956778e">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ae470fc-997a-46ae-831f-7599745f33f6">EV <link xl:href="http://snomed.info/id/271921002" xl:show="new">(271921002, SCT, "ECG Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e491e218-1096-456c-94ca-fe04ec47728a">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7471eb2e-63d5-4ca9-a8d4-3f8ef4123a21">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e3adfb4-d78b-4126-ac4f-77b7c0f15640"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_33cd738a-4436-4548-a30f-9898d275fab6"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_557130d6-3378-4926-9406-61b514511c9c">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c3e0b0e-00b2-4e31-ad41-7056a4db5ae3">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f69afcd5-8615-4416-815f-35cc48b411fa">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6fa2bf8-3a89-48f1-9f7e-bb65f6bc5de0">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a9fb4b7-d73c-41cb-aa26-9cac0bbce9df">EV <link linkend="DCM_121051" xrefstyle="select: nopage">(121051, DCM, "Equivalent Meaning of Value")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cc61438c-0978-435b-ab6b-8c1671626325">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3918a86b-826f-4c01-8ec3-22a4378b7e15">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10961aee-26ea-49a1-99b8-f429c417d428"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e76ae99d-ddad-4066-8fd2-e2750eb88e36"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_89d89629-419d-4f41-8a84-867d69ce4546">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8939395b-0fa6-4a8a-9011-62bd8ca9a6be">Rows 3, 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a0b4715-24dd-4827-9ce3-592d52cbb7d7">ECG Finding provides one or more coded interpretive statements using standard or implementation-specific codes. Each coded finding will include a Code Meaning (0008,0104) using the LO Value Representation (64 characters); longer human-readable text strings for interpretive statements may be conveyed in the Row 4 Equivalent Meaning of Value Content Item.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c804ad82-4099-4980-9f8e-98c1baada0a7">Rows 5, 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c1e9348-d516-4bc8-a132-8ca24bff2c42">Each primary ECG Finding of Row 3 may have multiple supporting coded findings in Row 5, with longer human-readable text strings for interpretive statements if necessary in Row 6.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3718" status="3" xml:id="sect_TID_3718">
                <title>ECG Interpretive Statement (Retired)</title>
                <para xml:id="para_de376524-f40f-4847-bcf0-8be9740d5db0">This Template is retired. See <link xl:href="http://dicom.nema.org/medical/dicom/2009/09_16pu.pdf">PS3.16-2009</link>.</para>
            </section>
            <section label="TID 3719" status="3" xml:id="sect_TID_3719">
                <title>Summary, ECG</title>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4598b2fd-438c-4640-be5a-a62e82eb228f">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_979c2e78-687d-46ee-aa27-c25608db5b6b">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_437d925b-96c0-4083-bc90-fc7efaf228ee">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3719" rules="all" xml:id="table_TID_3719">
                    <caption>Summary, ECG</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_48ea2af2-e41f-43b9-bd87-bf64e78ee092"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_57f82752-8556-40af-a4ce-2d496afbba18">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c1d7dba0-da29-477e-89e0-f3467316f735">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_21bcf585-8d3b-4f01-b615-3797885272ba">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ab7d103d-d5aa-44cd-ac2b-37adb07c1097">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_585ee40b-1f16-44d3-a998-65ce78f2ff45">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_26f59f10-d1bb-49e3-9d63-db179066c3ea">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_494e4583-014c-47cc-8c65-0b7aa8bcbcf6">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_afb30dc8-2698-4c9c-8900-9938d74a4b4f">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca236661-58eb-4e8c-9501-33fa47bf0ca0">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b7935d6-12f1-4209-bef9-019af6f3c756"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11f55420-d7f8-46b4-9b96-e522a5829342">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_adbc7941-9500-4f59-9edd-a134cc6d5a2b">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54e4df66-1116-48de-96e5-8f95eceb66a1">EV <link xl:href="http://loinc.org/55112-7/" xl:show="new">(55112-7, LN, "Summary")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3df01d6b-1d53-49c2-9705-a8796608f2c8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7ce6219b-1368-4015-b990-4926fe9b8f31">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca77e60a-cac8-4728-9e60-b6395726ada2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bfd8c1e3-0d1e-4de0-a661-8663834d5aa9"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e697e3e2-c3fa-448e-8fe4-002077c209e4">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b688ad1-d28b-469b-8009-f5a5cc528451">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3fe1056f-f554-408b-9903-e9dcbe52b23f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_460f123d-7f9a-4a93-94e4-8690c0d204e9">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f86e0e00-73a8-4556-bb64-4f62e508361e">EV <link xl:href="http://loinc.org/55112-7/" xl:show="new">(55112-7, LN, "Summary")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a51e4de-14dc-45a3-90cf-c2a799127aa9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3d16f593-83b2-4bda-a94a-815a63844c1c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ed168b1-aadc-4c01-b565-a79b27ec1ce8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0a4d1fd-d721-45b4-9e69-4f2374571e92"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf543a22-5d4e-4109-82d4-be472590e9a6">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e916e38-783b-4e50-97b1-73ef8202f1c5">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8dd8c67f-b138-4a41-9f28-ef7656bc13dc">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_456478e5-dd7b-45eb-99a2-c511ae91f5f5">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4596c3e8-4c63-4617-b879-1b71b24c7845">DT <link xl:href="http://loinc.org/18810-2/" xl:show="new">(18810-2, LN, "ECG overall finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_159c2be7-1617-4a24-b101-371617ee521e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e52757ac-de8e-41ca-91d8-5bb6409f9f81">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f09723f1-441f-4cd9-b7b6-02e9540a940c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e305dd3-4308-47fd-acd0-074e3674cb9a">D<xref linkend="sect_CID_3677" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
        </section>
        <section label="Waveform Annotation Templates" status="2" xml:id="sect_WaveformAnnotationTemplates">
            <title/>
            <section label="TID 3750" status="3" xml:id="sect_TID_3750">
                <title>Waveform Annotations</title>
                <para xml:id="para_ef49460d-214a-4418-8ee6-db27aeff3c92">This Root Template encodes a list of annotations for waveform data consisting of measurements or observations added at recording time or later provided either by a human reviewer (such as a cardiologist, neurologist, or technologist) or by an automated analysis algorithm.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_db3dddd5-dba2-496c-ae65-e8d6df40f7ed">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4f1f0f82-6fec-4eed-94c6-93dc5c156bfe">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_28386a89-af36-4475-924b-04c93a565fc7">
                                <emphasis role="bold">Yes</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3750" rules="all" xml:id="table_TID_3750">
                    <caption>Waveform Annotations</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1"/>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bff9ab7e-276f-48cf-b34e-9e311bb2238e">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_64dc8392-4871-4a2a-a613-3b90666d4ca8">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1f29697a-312f-4120-90a8-12ad9dd3e524">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7f37bfa8-0f63-4223-8d98-c3d50b56ce7d">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1768d631-93ec-4a4e-a805-d8d0e6788976">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f175f96b-3011-44a8-b2cc-aa4adf26ce3e">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7db4980b-031d-4aa0-b175-d446188bfbaa">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b36c5bbf-70ef-4aef-ae41-bcd185e990db">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_483fdeb3-4352-400e-9dfb-b2695e23c26b">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d7605c5-ae51-4468-856f-038aabea9873">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1e1ad6f-0c73-4e45-82bf-af1f77eeba74">B<xref linkend="sect_CID_3048" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d2c1cbf-4796-4309-9622-2ecba8f68fd5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_261e466f-f00f-497d-b1c9-2c17c447a1f3">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3b65399-4c5f-4a52-99ec-fb4b558823f4"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b55fddff-1489-4c28-8c66-7253385308bb">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6a1de86-2f8e-412e-85e1-ef3e8a644ff7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65c85a5e-51f8-4cc6-a38f-4ef6abde8709">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59917674-b08e-4ebd-989f-5f50edf15809">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0586d2a9-41ef-4fe8-a42c-1a0b4d4cec96">D<xref linkend="sect_TID_1204" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5cb979ca-2b11-4771-8c68-e6b55286fb2f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_232821ad-8eb4-48ba-a2eb-26581313c6fb">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3dd8674c-b8ff-4f3d-877e-34d456b12e65">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c06c2d18-bda9-4be3-862b-4dea33236a3b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb24b556-843e-4161-99cc-327e1eca420e">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0c564f3-af90-4726-a066-4318d14e3667">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a259341-dc55-4808-a710-45161df89ded">D<xref linkend="sect_TID_1001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b15917b7-80dc-4cef-a196-2f5670e15dbd">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9416cdb6-6290-4006-8123-825a8038128e">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_76d74cc3-f9ff-4ec6-8509-a7d8a8a57850">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab7ce5c1-7bee-4f7b-86b4-3fe125a4f8d9">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2751ad23-5236-4ddb-92c0-6a1a92e2d093">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2929d2ca-ebe5-4b41-b2a6-c8fd1606c951">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8a3b83c-8ab1-491c-88ce-f5a719362e18">EV <link linkend="DCM_130871" xrefstyle="select: nopage">(130871, DCM, "Procedure annotated")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ccdfd033-9023-4006-953d-1d26e5587bae">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dc3ff084-3922-45f8-a971-281c70ffedfd">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_20f965a2-9df0-4e3c-b315-091f42b44752">B<xref linkend="sect_CID_3670" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_611d2ef2-68d1-408e-a6a5-48a4e9a32d8f">B<xref linkend="sect_CID_3049" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_297bb1ec-a174-4697-8b89-b01dc3dd1261">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f48860d2-d578-429f-9ce7-cfe55c23b3f4">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a60178e-7fea-4fbb-ab66-efe2b94fb9c3">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f780fa98-3a34-4452-9001-ab1d39ba3e21">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e414c93-a3f8-4b6f-b80f-f5b26d73d7c3">EV <link xl:href="http://snomed.info/id/1185780006" xl:show="new">(1185780006, SCT, "Relative Time")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_37c0ad6a-5445-49a0-a7de-46dc5a00c40f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ff51e82e-084b-40f4-a4db-42b3feb20261">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d7230fa-f396-4cc1-a0d4-87336ca5ad38">D<xref linkend="sect_CID_12102" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_205b89cb-e817-465b-a208-a1a3f6aadb96">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b004d8c7-26cb-4917-b630-7bdf43e69e46">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_263df28d-195a-4b9f-9e0e-5c23f7e82332">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc391edf-fac8-445b-b351-1c2e190c7c4a">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8da18e9a-7f81-4c56-88f6-f35ee8cab258">D<xref linkend="sect_TID_3754" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_433b3b33-9e4c-4d98-b0ae-8151ddfa8065">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_de8705a8-07b3-47b8-97a9-51a2a0b83673">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_28e3aadd-587d-4ea9-863e-d0ef509bfb5e">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98018cc7-b1ea-4cad-b695-d884d75b3ee7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4eea2aaf-60e0-41e1-9b59-b62f62973e5c">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_07db0742-68dc-48b4-b466-adbc44bab729">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1956f5f7-fce7-4a80-8ec7-f828adb0ab59">EV <link linkend="DCM_130870" xrefstyle="select: nopage">(130870, DCM, "Waveform Annotations")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d1f39314-4381-4aa3-82ef-f748b0692bdd">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1338e86c-c90a-41f8-92e2-8a09cc28df39">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b258eae3-f607-4462-9c65-97a3446bd185">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8412fc45-52fb-46d7-ba92-7e13a7f917dd">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5587d511-38e6-468c-a858-c372fea8524b">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_595995c8-55c4-44f9-bc99-4ba292ff9c49">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e47041f4-22b2-4a27-ae62-b80ee5f42792">D<xref linkend="sect_TID_4019" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_576d1a90-6f7a-486a-a160-fb2403501fff">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eb410b44-f98c-4c4f-9557-9bf090f0ee92">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ccfe94d4-155e-4a64-86df-41406abac7dc">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb49217d-a43a-4410-8848-9648a9759a93">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e8fea15-454d-45f3-8e37-c61baec9b86d">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3227f743-e3f3-4477-8a82-1a1e60e7918d">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_912c8376-5190-436b-a4bf-8833e3b2cdd9">EV <link linkend="DCM_130872" xrefstyle="select: nopage">(130872, DCM, "Waveform Annotation Group")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c99daf2-50bc-41f8-9eb4-837a349da196">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1857092a-a037-4b57-941f-b7e4846e56a5">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9de700c0-a821-46b0-82c9-ab4620f45c2d">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3fef3736-a62b-4227-95f0-4094e50de2dd">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b5ebf5e-01fe-48b5-82cc-b7c4b300b7dd">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2d1e852-232f-49c2-9019-34b0418daf20">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c801dca-fabb-4bc1-aa94-3f26abeb7220">EV <link linkend="DCM_130873" xrefstyle="select: nopage">(130873, DCM, "Waveform Annotation Group Number")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1792cc9a-6192-4f19-9d7b-12a407e711f8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_20de064e-35bd-4a2b-8a9e-8e882141b648">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e615595c-951f-412b-a727-ff3b421e316f">UNITS = (1, UCUM, "no units")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3fc93597-0882-484d-8b18-d52a0c2ebf22">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e59d16c6-da5a-438a-8bec-5e361bb5fcb8">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee6b5e14-f206-464f-a8de-8e35bfca677a">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96a5bc5c-2e8f-4b48-b32d-4e549d1eb53c">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26cc7019-53dd-46e6-bf9a-ab07b901d1ba">EV <link linkend="DCM_130874" xrefstyle="select: nopage">(130874, DCM, "Waveform Annotation Group Label")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a4f58519-7930-40e1-9c61-b883ed9f77c2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b9e6b44f-f30e-4131-a46b-57dd123afe53">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_deba5eb1-44c4-493a-86f9-00ee94e414d8">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5fbfbc79-7758-4d55-8b1e-59ccf647a006">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_34dd2656-32b6-4e78-9ecd-a31e1e636670">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1ca6bba-13c5-478b-9a20-34ff61b6b0c7">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6544179a-644d-437d-810c-dd8b2d04d18e">D<xref linkend="sect_TID_3751" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f485136f-bfb4-4b16-b728-dd11ef1433d0">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f444b561-7a74-490c-a57d-ffd363cb905f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_238db909-61de-4c56-a9c9-a0953121363b">$AnnotationClassification = EV <link linkend="DCM_130860" xrefstyle="select: nopage">(130860, DCM, "Pattern Event")</link>
                                </para>
                                <para xml:id="para_0348592f-7bf6-4a8b-ba11-41ecce0edc9c">$AnnotationCode = B<xref linkend="sect_CID_3038" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2b0f553-dea0-45e3-ac41-29b58c47c95e">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_019230cc-6340-4fc0-95ee-c7e4ffc01b13">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65bb1a83-852d-4dda-ab80-8a7561bdba70">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5dbf3a5-8990-4ffd-babd-85173be7de73">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26646d2d-5138-41c6-8110-e1f5952ed14c">D<xref linkend="sect_TID_3751" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2a75c8a8-a8fd-49f2-8ba8-6ad6ad1b2ded">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73044893-4f12-4f4f-84fd-460a264e5308">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b90aa388-6da4-44e0-9132-2bcd6a9afe80">$AnnotationClassification = EV <link linkend="DCM_130861" xrefstyle="select: nopage">(130861, DCM, "EEG Annotation")</link>
                                </para>
                                <para xml:id="para_89ae7d73-531d-4f82-99eb-0f81b3464209">$AnnotationCode = B<xref linkend="sect_CID_3035" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_645859b3-81a4-4da7-a3d7-d9bdf93ce4a6">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c2b99d8-5929-49f7-b7df-544542741667">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_14287cd4-47ff-45d8-a987-5a144952ae16">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1689d34-69ec-4c7d-8293-fc4dfc2452cd">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_47a04f9c-e3a2-48c0-bf0a-2d3b9706e51c">D<xref linkend="sect_TID_3751" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_07eaa711-4007-4274-97b3-edfbc36eb3ec">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_42ed7249-6653-43b1-9dfb-0d0b8f04fba3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_654a5320-b8fe-44e4-9033-8257e995b411">$AnnotationClassification = EV <link linkend="DCM_130862" xrefstyle="select: nopage">(130862, DCM, "EMG Annotation")</link>
                                </para>
                                <para xml:id="para_fd1084bc-9413-4620-81b0-80f695958d94">$AnnotationCode = B<xref linkend="sect_CID_3036" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c1a68fd-5613-499b-a947-6a0f496e721c">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce782918-55cf-41a3-8de1-854db71fd32f">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6e1189f-1ac5-43bc-b892-118105cedb01">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51853511-b6ec-47f5-b79e-8504fa1578a6">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6aebffe-1965-4fb2-848e-7f0a829e8c58">D<xref linkend="sect_TID_3751" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a399b1cb-74c2-45f2-b1f3-0bf1ce581e59">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_292e58a9-fd25-4437-8ae3-96fdd345ebdd">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b3160c3-94d1-4c27-bc8a-a29366e75351">$AnnotationClassification = EV <link linkend="DCM_130863" xrefstyle="select: nopage">(130863, DCM, "EOG Annotation")</link>
                                </para>
                                <para xml:id="para_15e7f976-a4d1-4a32-8620-9e24f2f23975">$AnnotationCode = B<xref linkend="sect_CID_3037" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8fbca93a-05b1-4822-94c3-021c7eb0550a">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ac4b67e-5d17-4a53-b906-5f80e81cdf55">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c02ccfe-860a-4380-b27e-1a632fcb13c7">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42e8ff90-3722-4fd3-b7d7-a1dedc894232">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_708d231f-7ee1-4ba4-a608-cfda0e7ceed2">D<xref linkend="sect_TID_3751" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_49c888d4-4268-4239-88db-9e33fde28f98">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_80319c95-050f-481b-ab24-19dd9e90396b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d76808f-d136-404c-91e2-9ab8caf6b2ef">$AnnotationClassification = EV <link linkend="DCM_130864" xrefstyle="select: nopage">(130864, DCM, "Device-related and Environment-related Event")</link>
                                </para>
                                <para xml:id="para_ce78ab76-30ad-4b7d-ad6e-59adfa32db8d">$AnnotationCode = B<xref linkend="sect_CID_3039" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86c538a7-1c31-4088-92e4-bd60739a7c5c">17</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e1272ed9-3409-4d0e-8b64-b02786938f09">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e528262d-e937-4245-b52e-c2d2ed8e61fd">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50fceec8-010b-4698-bef7-6b526c5e589c">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c08f2387-8cbb-43db-8e88-af97d4150edf">D<xref linkend="sect_TID_3751" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f3202829-c64c-456c-a46c-21bd4045765f">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_056ef5e8-6630-4ac8-9c3b-46c8355c44b8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a84fc87f-a82d-48c3-9717-8d795fc2384e">$AnnotationClassification = EV <link linkend="DCM_130865" xrefstyle="select: nopage">(130865, DCM, "Patient Consciousness")</link>
                                </para>
                                <para xml:id="para_7c7a3eda-a725-46b4-a9bd-e93b995d7c6b">$AnnotationCode = B<xref linkend="sect_CID_3050" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae00b55f-7c91-4d66-b15b-ce4191b34df4">18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c6c3e4f-0439-4283-b99b-58c0672b2bdf">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c98158fe-1000-4513-880e-4d64e17f0194">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50ae6247-d8c1-4e31-874a-477c23551d81">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_56cd4505-f7ec-4293-9ba1-563177cc4bdf">D<xref linkend="sect_TID_3751" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e4bc8c34-6397-4b43-b71f-d0cc4b20c00f">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dfbd0893-c634-4c20-a551-f64e5a5e9b0e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd2888d1-4b0b-4ee5-96b0-1ed22efcbdd0">$AnnotationClassification = EV <link linkend="DCM_130866" xrefstyle="select: nopage">(130866, DCM, "ECG Annotation")</link>
                                </para>
                                <para xml:id="para_382a829d-b5c1-4430-b9c7-dc0a0d752727">$AnnotationCode = B<xref linkend="sect_CID_3335" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a8e8866-951b-44ab-b548-f6f1a4fa3def">19</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0bf4181-0f72-4393-828d-942f5076b523">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_692b5478-8b47-4935-a25e-55ced0dc3e58">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e63e3fc8-1d7b-471f-b960-555aa8d63324">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_442745f8-33c0-48d6-b1c2-85ec6e4c0580">D<xref linkend="sect_TID_3752" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_32013fb5-36fb-41de-a301-4e59dd3afd78">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_22de9677-3c6d-4dca-a8f8-1e0e44acdb85">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_407f6d00-7cf0-4ca0-9f25-08876f2d2bc1">$Measurement = B<xref linkend="sect_CID_3040" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dac74d09-722f-4b60-b2f3-3cfdcfde6275">20</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac80ba28-cd19-46ff-bde0-201fc3cee417">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d0826d7-d6ce-4c60-b215-6e0003e7cade">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97d5b7ff-bec8-4bb0-addc-7813dbea1bf5">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe747e19-ac4f-4933-8ee0-841b6c4899ef">D<xref linkend="sect_TID_3753" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_023579f6-536b-43b2-b936-708c62aeb89f">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9e7112bf-d37a-41f5-ac1b-f5cb0fdda7d1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_6e508df6-8fe6-4b31-81e5-6013438084fc">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_34719887-f725-4435-802e-450b6ff6e2f2">Row 4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_076f9275-87fe-4519-999c-371928673f1e">A coded descriptor of the sort of procedure the annotations apply to.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e824171-517b-4193-b15d-36ab7c5a8274">Row 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0a8954b-0508-4f99-aacc-38ae0736277a">Indicates the point in time when the annotations have been made relative to the waveform recording procedure.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cbab04e3-f839-4e43-939c-3480178f740d">Row 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_479fb057-ae46-4a3d-945d-ced27cee3b28">The Waveform Library provides potentially relevant characteristics of the waveform objects associated with the annotations. There is no requirement to include all, or any, of the waveform objects referenced in the annotations and measurements elsewhere in this template. The template may also include waveform objects that are associated with, but not directly referenced in, the annotations and measurements.</para>
                                <para xml:id="para_4f0137b6-1df3-43d1-9159-fa71215b766a">The Waveform Library is not replicating the content of the SOP Instance Reference Macro.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43043039-e709-4b53-8ecf-12cd93118cd0">Row 10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2041d001-397b-4b5b-a5c7-34e1276bab19">Defines an identifier for a group of annotations analogously to Annotation Group Number (0040,A180) in <olink targetdoc="PS3.3" targetptr="sect_C.10.10.1.4" xrefstyle="select: docname label"/>, which may be used, for example, for display purposes.</para>
                                <para xml:id="para_5f674c9c-83fb-4d11-93ae-7c861660d579">The number itself is not semantically significant, no ordering is required.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3005276-aeb1-4553-8734-711519b10ead">Row 11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b52d4646-af2d-4600-b442-adad6c20d1be">A descriptive label for a group of annotations, e.g., to be used for display purpose.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3751" status="3" xml:id="sect_TID_3751">
                <title>Waveform Pattern or Event</title>
                <para xml:id="para_9702c6d9-d877-4718-8eb0-41ac1bebcde3">This Template encodes a Waveform Annotation represented by a coded concept.</para>
                <table frame="box" label="TID 3751" rules="all" xml:id="table_TID_3751_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5500b197-9032-4761-a03d-359810299034">Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f8f164d1-5dc5-4eeb-9978-d923ba137356">Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_556667eb-ef03-4173-811d-26b777401792">$AnnotationClassification</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_360b2cc3-f004-4f69-b402-07dfa14a09c9">A coded term or Context Group for Concept Name of annotation type that determines the value set constraint.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79d83aee-ae81-4365-82cd-d68855813f14">$AnnotationCode</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_496a3452-1c4c-4c4c-8d59-8fa4384ffbb5">A code or a Context Group with codes representing the observation.</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_15ec3e63-925e-4ca3-b2f1-3b1e51be614a">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_c68be3c9-fd80-4772-961b-dbd0a950b948">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_d94bcba6-602e-438f-908a-686a7cee24f4">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3751" rules="all" xml:id="table_TID_3751">
                    <caption>Waveform Pattern or Event</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1"/>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_02a8feb2-67a1-4f9d-8d9e-ed35df87ce4d">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_15d0a738-7b67-4dae-af1a-14b322ce0e80">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_10c6e433-dc1a-494c-b999-2ed37faf647e">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f161c95-09ec-4a7f-96ee-88494c366069">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bff71139-d8a8-4e3d-8d6c-391f0babb33e">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5a278634-b8f3-417c-9e17-f25550c287f6">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_49c0cf42-1555-44c1-ae3e-48396fbd1748">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ab0d878-b435-4415-a9ea-088cf73a3e09">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>

                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3eaa10f-44bc-43a0-bce3-09aa4487af4b">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65ffe562-d07f-4e1a-af6e-3870bf064aa5">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27b028d1-64c7-4d45-8f37-d3489ea25316">$AnnotationClassification</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8bcb91a8-bc92-4d8d-be66-26f73a38b2b3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8ac62469-962f-4c38-b29a-5c075274296f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f3dda6e-aedc-4532-8e54-c3b91a8b2312">$AnnotationCode</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af8846ce-d4d8-453b-9086-be6956cc6bcc">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3973b0ff-4e56-4a1a-b92f-99b04a879043">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6cec908a-3b06-4567-a227-496d46e57cf8">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8fe67a23-0e25-4be2-b995-1e042d8d503a">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d86329e1-ab7b-4450-abdf-df5b127346c8">EV <link linkend="DCM_130875" xrefstyle="select: nopage">(130875, DCM, "Waveform Annotation Modifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c43d0002-117c-4ea4-ae9d-78cd8bad0825">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cd645d54-5b63-4cf0-8ed4-a1146f20d8ef">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7dddc3e-0bb7-46cd-818d-9d3fb819d35a">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ad6af00-8c80-4022-9d68-a644c090eb35">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5fd11043-9b0d-42b3-92bc-e50b479508ff">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5f46e92-79dc-4785-b033-91c81954ad5b">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eecb9423-af0c-42e1-8c22-7d127c29a474">D<xref linkend="sect_TID_1001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_06bc9eab-e4e2-47e1-a221-b5b96bab214a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3e813f34-f96e-4df9-958c-6f15303bb038">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_484005d6-0c24-409b-9fa3-3cc3f5c35e15">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_616bf536-e388-498f-bc66-9a89a43de37d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63d7b4c2-a76f-4edc-b1f7-5e03dd13848e">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc3965de-8edc-4db5-8b2a-8151c09d4675">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e646f84a-4063-47a4-bfc0-b15024222e2b">D<xref linkend="sect_TID_4019" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_177109c3-c379-49b5-8b03-dcb0a8781748">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_81637f95-fe34-4012-9a1b-f49b2a539cb9">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a07023aa-ff15-4ce7-aa90-342101819ac2">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_866e0bde-f611-4e7d-a9cf-b594961cc08e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_631f65d6-d3eb-4f71-aa9c-7d169e8df208">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_19f3c95e-d1b5-4839-8c09-75028c67a465">D<xref linkend="sect_TID_321" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_22030da7-577d-4e79-90df-59ad588804e2">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d68118f9-9913-4da4-9f4b-d7ee9c5fe5e5">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ab2ddcd-9926-4750-8770-fe30fd4045e1">$Purpose = EV <link xl:href="http://snomed.info/id/260753009" xl:show="new">(260753009, SCT, "Source")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83ef817e-612d-4fee-bdbe-3e093cd01e35">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d7ea3a05-8c8c-49b3-aee2-2e42a1508cad">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96fe679a-20d6-47b1-b5c2-25317712f3f4">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_33ef132d-1714-463c-a444-78a1ef4299c5">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_513dc2c1-414d-459a-997a-47bffd516e2a">EV <link linkend="DCM_125309" xrefstyle="select: nopage">(125309, DCM, "Short Label")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f32c3916-174e-4657-91ec-a17843064b74">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e1f80e53-2bda-41c6-876f-359c15b33eb5">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_779310eb-e167-4b08-b050-ddab8eb7d5d4">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2049a392-e95c-4da6-8bb8-32e7fba56b26">Row 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3dc7f471-fa47-4796-8480-e506dd54b00e">Contains additional qualifiers, if the value in Row 1 does not fully define the annotation. For example, this might be information about the location of an observation or the frequentness of a pattern.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5f80184-1872-41cf-8fea-a6881878819e">Row 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d5e4cfc-e87f-4383-85c2-d8b5a49cce96">This may be used to label the coded annotation when space is limited on the screen or report page.</para>
                                <note>
                                    <para xml:id="para_3065ed08-c828-4a49-a203-7ec6747e7b5b">Short Labels are not standardized and may omit details of the annotation; thus, it is not recommended to use them for purposes such as matching.</para>
                                </note>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3752" status="3" xml:id="sect_TID_3752">
                <title>Waveform Measurement</title>
                <para xml:id="para_b26d3a2d-3008-41de-9897-845950bc195e">This Template encodes a Waveform Annotation expressing a measurement.</para>
                <table frame="box" label="TID 3752" rules="all" xml:id="table_TID_3752_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f5ed8fe4-a31f-4f9e-8a76-e4d9f94f7cab">Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6b778e59-2d67-4bb8-a989-635668bbac72">Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6db89907-7e12-4dc5-a1a1-27d6d740e0e3">$Measurement</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72839644-8c48-4a66-95fe-b427a8c3be9d">Coded term or Context Group for Concept Name of measurement.</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_9a7f4fef-8c03-4f08-8c41-e7ceeabe31ca">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_d4555d9f-e730-4d14-81e4-e59ae1031ee3">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_975c8dab-51dc-434d-b610-630dab0e7185">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3752" rules="all" xml:id="table_TID_3752">
                    <caption>Waveform Measurement</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1"/>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e5a55325-b8fb-40c7-b012-3d6bd46dc3b5">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e1de29cc-81de-4de0-99c6-a8b0857363b0">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f0fc14b-1383-451b-85d6-e2f8c468b062">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_34ad973d-003a-4e18-86b2-4f851ef70842">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9f9d4e05-0913-4ec9-9730-1f468bc67a82">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ce4c6418-8141-42ed-a306-c7a9802f382a">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_49404ae5-1c41-43d0-bcd8-a774372cc876">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dca2922b-ed46-4886-a91c-c69bd154c595">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c6c79998-3420-4217-8e60-831df4fa856f">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4bb01f5f-be19-4e2c-abef-7ad244259630">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ec02ef5-b104-4043-833d-6804b1fd6ea4">$Measurement</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_580f5854-821c-49b3-8305-3d48995c4122">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7f754bfe-4208-4d26-b18c-f24e3fdcb1bf">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d7634f0d-31ce-4b92-8183-0b93e2176cde">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70feee6d-209d-46d9-89f5-10a1f7bc8e44">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c568b788-6eef-484a-8f71-6a0da9a47cae">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8ca348a-c600-4969-8d33-141236f99ff6">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c9e949d3-328b-461f-9707-1055d1b2186e">EV <link linkend="DCM_130875" xrefstyle="select: nopage">(130875, DCM, "Waveform Annotation Modifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2ce1dda4-1443-44e4-bf96-8ef4eab1a999">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b4f178d9-b43f-40bb-8478-86143363b2da">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0085a0b-f99b-4a0b-91b5-272edc7af3bc">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0343b8ff-e974-4d07-9ab7-e426fec5929d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d4a1127b-b393-431a-bcd0-fe61ce8acf94">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf0ca396-b455-4e8f-8a5d-89714fcb4cb3">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92852a2c-c754-4b34-887f-d09c9623035f">D<xref linkend="sect_TID_1001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5444a685-41b5-4d21-9d44-ec9ebc1af57d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_143c61d5-a6ca-41ad-b7b9-4ce62ea11fd5">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dab9e406-4f46-4cbb-9064-9d82b2a27b89">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cad05273-9bd0-45f3-87fd-bf8d7ef09b3f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6bc0b66-52f3-4d8b-be1d-8ef57fe10a92">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_acf430ab-f75b-4a15-a092-4f9a772166dd">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb294293-3f88-4c42-a3f7-b3fb217f93f6">D<xref linkend="sect_TID_4019" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3a89bbf9-12ae-4d2b-a84b-df6e399c791d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2d57cba4-69ec-4b0d-832d-3a76cb286d28">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4b5e533-0e11-47ee-b305-6c03ffb2f9a9">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2aaa117-c093-4e29-a48d-26b91b4d1bac">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ccef6239-21d4-416b-b53e-7cc11002d61e">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9df4a0d-5542-4018-ad8e-495a7a94fe08">D<xref linkend="sect_TID_321" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bb5000bf-f9c6-40f2-8021-5ad10150fb58">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f8316065-4521-4c50-84f9-8a541317c61e">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_daeb8726-98f6-4229-9c7c-ec05b3fc969a">$Purpose = EV <link linkend="DCM_121112" xrefstyle="select: nopage">(121112, DCM, "Source of Measurement")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a13733ce-3bd3-472f-abf2-d7536f972da8">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_125d02ba-a570-428f-9029-f2cec5584745">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0c19281-4a5e-4530-ab50-2d0772c1df95">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d9758a7-f461-45b0-8da4-c044835626f1">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a0203d6-8270-4247-a51f-e4c46dda9ed9">EV <link linkend="DCM_125309" xrefstyle="select: nopage">(125309, DCM, "Short Label")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3fc49002-5863-4a58-80ea-777402f35c02">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cb659fa5-db4c-489c-9332-810b71fd7ff1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_1b1a37dd-926e-4b6d-aad7-968656a4361a">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f92fd4a-3a20-476a-b6a4-4d5d0093003c">Row 6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6fdd7044-9dd8-4a08-9d33-4aaea2062011">This may be used to label the measurement value when space is limited on the screen or report page.</para>
                                <note>
                                    <para xml:id="para_7ceeed30-6f34-4420-878c-6c9102622332">Short Labels are not standardized and may omit details of the measurement; thus, it is not recommended to use them for purposes such as matching.</para>
                                </note>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>

            </section>
            <section label="TID 3753" status="3" xml:id="sect_TID_3753">
                <title>Annotation Note</title>
                <para xml:id="para_23247562-1e8a-4c23-a2e0-105ec5a18596">This Template defines a Waveform Annotation in the form of a text note.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_65df7a4e-1639-4aaf-9ae5-6631103b27a4">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_dbc371d8-f254-41e2-9864-0c886c807bef">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_025336f8-7651-47e0-8931-55fb8511ca45">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3753" rules="all" xml:id="table_TID_3753">
                    <caption>Annotation Note</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1"/>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7fbf9fb5-da34-4cdb-92fe-beb2f5a2e54f">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4119e83e-2197-41a1-a287-0925550954b5">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_572e2764-d3c9-4cc2-95e0-c86325694634">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c870213d-d2b1-4da6-80a6-b00053cb102c">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9bebda30-f0a3-4833-a8d6-beb1952c8ecd">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_51b747e6-9db5-43a5-b8e0-06639ba83006">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_92874e14-9039-4d55-a1dd-0e67095338f7">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2c6a5f63-c3c9-4d22-8151-1fb1bd0b02bd">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>

                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4446a20c-4de4-4c61-befe-9e1aa530f3c7">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37c92dd4-406e-4731-8b8e-a4f3877a7f09">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4dde2f2-9b5a-427c-949a-9a551e963f7f">EV <link linkend="DCM_130876" xrefstyle="select: nopage">(130876, DCM, "Annotation Note")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_22896f13-1d96-418d-b08b-8572def6229c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_38d50e8c-01a9-46ab-999a-caa3410f269f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4f17b9a-59a8-4e8a-b553-cb7aede785a0">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e0fba09d-d032-4814-b971-18c68ca72a82">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ecb834b-b3f4-48fc-9323-65d4dbde4456">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b2e902d-8322-4598-9fce-231cc75da56d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4469646e-aa7d-47d2-8e61-0b1ecc549d62">D<xref linkend="sect_TID_1001" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fe7263bb-62e2-46d3-84b0-9718488b8091">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_51d382c6-fa3c-4179-97c6-015290c328c7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92952e05-a721-4738-89a4-bfab2cf0ff4b">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30ff153d-5e58-4590-8483-b36f8a984250">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ee7a71a-1f28-4b16-b7c7-23cff97a8ab1">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7bbcc2b0-8823-41f8-83ec-08f1932cda83">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7ac4ab2-0725-4de2-ae49-96633dd7762a">D<xref linkend="sect_TID_4019" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fbaa15cd-80b8-4546-957a-1029917bcfca">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_90c0ccc5-95ee-4987-9ca9-d587607ca35a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09eb3821-7b39-4e0e-81db-c0dc18eff325">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7bfced7-d10f-4c37-8ef3-dc5c7db3ba81">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4714e2e6-de41-4966-a783-dceea9e4ca96">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c2ab0b48-c7a6-47c1-8664-f93abfcce80f">D<xref linkend="sect_TID_321" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_df323ee9-6565-4031-8737-069dcf90f357">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3f662a7a-0cce-4234-94a9-aa1e0a802bfc">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f91992e-fde3-42c4-bef3-746c7579d679">$Purpose = EV <link xl:href="http://snomed.info/id/260753009" xl:show="new">(260753009, SCT, "Source")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24b1437c-c2d1-4672-8260-c541320ebf87">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_efaa3a2b-3d55-4b8b-a3b3-b90663a66299">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca3ee7b4-2e2e-4253-a3c6-30687383ab78">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8243fc7f-01d5-4c42-b779-a6848934d3de">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0af08b61-7fcf-4976-a587-2cc4ac5a41b5">EV <link linkend="DCM_125309" xrefstyle="select: nopage">(125309, DCM, "Short Label")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_33526a11-fffb-4fe6-a8fd-e0e12266ce3c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e5614cc0-8561-45ca-8ecd-9c13ffe14ec0">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_b09150d0-2a89-4702-a047-4f9165cf537e">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e042957-3a82-4fdf-9151-ede61d104223">Row 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3df987d-2a5e-4dc1-bd73-174b620ee2f7">This may be used to label the text value when space is limited on the screen or report page.</para>
                                <note>
                                    <para xml:id="para_773999c7-e53b-4d02-9857-d9d1bd1fffee">Short Labels are not standardized and may omit details of the Annotation Note text; thus, it is not recommended to use them for purposes such as matching.</para>
                                </note>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3754" status="3" xml:id="sect_TID_3754">
                <title>Waveform Library</title>
                <para xml:id="para_79984d98-aaaa-45b2-b9bd-efc4d9be1ff3">The Waveform Library contains references to waveform objects and selected attributes describing them that facilitate analysis without having to retrieve the entire set of referenced objects.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_fa986f55-56af-4693-a523-f3ad7d3ee46d">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_e921180b-c010-4cf0-9e7f-0007f56e29c1">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_d931515f-b578-479e-8221-74c0aeb67eda">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3754" rules="all" xml:id="table_TID_3754">
                    <caption>Waveform Library</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1"/>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_921dc022-089a-42af-98eb-7bb603b4b879">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6e96c9c5-39fc-4bfa-ac23-c47625b0dbc8">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9faea448-d79e-40d7-8070-f95cf68fa9f7">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c4bfd405-aa2e-4b61-bce5-c0f404c9dc23">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f988773-f39b-409f-8f46-2c0248b1d2fa">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ea90c74-cbc0-4de7-bc20-c8e10fa9cca3">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c34de484-c866-4937-acdb-35f6f4ec2487">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ae103c68-0c18-4e3d-901f-353fc01cf9da">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d059a6e-308d-482a-9407-304eacca150d">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f641ee4-3bde-450b-b0b5-5578a0661ef4">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dea52f48-b857-4ccd-a0e6-9058ff3de6fa">EV <link linkend="DCM_130877" xrefstyle="select: nopage">(130877, DCM, "Waveform Library")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_13603070-49e9-426c-b3c4-961ef6b0d458">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4e57123e-2ccf-4a6b-a519-459acc4d0427">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd5291ea-e20c-4ec3-93db-74f7986b0bf4">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8865375c-4541-45ae-a897-926797ea172a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0ed3862-4b05-4876-b155-655aa271393d">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5834cdba-b2c2-458e-bba1-067d35f553ef">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6004d5a4-126e-4be7-ad2d-ab4781602f03">EV <link linkend="DCM_130878" xrefstyle="select: nopage">(130878, DCM, "Waveform Library Group")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dcf04c18-8216-471d-b818-9c77e84be6aa">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2def8814-96c3-47d9-8e8c-3b1371c1b5a3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a2fb108-179a-4a21-9f20-08785e94ca64">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df4d34cb-4790-4407-b1b4-97ec44f3e9a0">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d064596-7a0b-4587-8f3b-5dcb845771aa">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0253bc5-a49e-4ab0-b978-f5471ef1fdb3">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e4424c0-c89b-4ac4-9657-6f3d80b3e924">D<xref linkend="sect_TID_3756" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fdd655b2-1109-4247-a21d-96fd5fde6978">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0c6d7adb-95aa-418e-a16c-fd89da0114a9">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3ef7f16-60e5-46c3-b6c8-ecbea605af78">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0702e189-0454-45a1-ac49-42a0ae3d177c">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf914151-4a22-453d-8fbf-574685305554">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74df6109-d041-4f17-9ec6-eda41b10f4f3">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_322612fc-2de0-40cf-bc24-5538e2d54b56">D<xref linkend="sect_TID_3755" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ce0ddc44-1338-4d01-992e-79ef754b4c83">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d40182dd-09bb-4578-a1cc-2646efa41f72">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_32e708e4-8fd6-426a-886d-572c600fafe1">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0b250ee-369d-4bd8-b392-fbd5d90abb56">Row 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2fccfcb4-3095-4df1-9a64-eda5bcfeecc4">These Waveform Library Entry Descriptors apply to all Waveform Library Entries in this Waveform Library Group.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3755" status="3" xml:id="sect_TID_3755">
                <title>Waveform Library Entry</title>
                <para xml:id="para_3b3ec67a-7a76-4132-a40d-0ceef77088c2">Each instance of the Waveform Library Entry Template contains the SOP Class and Instance UIDs, and selected attributes for a waveform that facilitate analysis without having to retrieve the entire set of referenced waveforms.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ec540eb8-bbd4-4b25-b44e-f4183f857abe">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_0bed6fde-b0a2-410d-b38e-72289ed37d1d">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4366e60f-fb8e-488d-9ba6-af1fd1a39b15">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3755" rules="all" xml:id="table_TID_3755">
                    <caption>Waveform Library Entry</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1"/>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8acacf0b-03d2-45ab-878f-e1ecf516108b">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_544f16ab-f682-4316-bcf3-543208ba7b8b">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fd379905-8ffc-43d7-be6a-9772ab354aa4">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b5abfd84-3a4e-447c-a386-d1f81a334985">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4fd6aaf8-80bb-4291-96bf-434dc109509d">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8b11412e-4a9d-48c6-919e-75875d037d3f">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_31e51d79-6c28-417e-9aae-610933125df4">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_67c78b56-6cd1-4543-813f-7432a2e29384">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f58b4a0-3fde-48ee-a45c-8f8a6c9c2e9b">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7952434-7be4-4fe7-aa53-391ee6d3f19d">WAVEFORM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_36a38b34-c5f6-4b92-8e17-1d99cab013f9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a41fee14-9e79-445c-b5cc-cf2b4262a6db">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6035007f-073a-41ff-8e0e-dc2bd161b654">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54091480-519a-4e79-a605-7ea82085d016">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ec069d0-3c81-4e0d-8b9b-2deb2a766ebf">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2bf62917-a84a-4d5c-9005-2fe56aebf1a1">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0c12171-e337-4c07-9eee-caf727f3dce4">D<xref linkend="sect_TID_3756" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3d25bcc2-2749-4b3d-b44f-c06a75998637">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f5248a93-dcf0-44e4-9839-d1d00ae95b3b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_e23dd11e-abdf-4331-a75d-1ed18bcaef1c">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_742cabc7-362f-4109-aacc-2b790c0ef96f">Row 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d84a1749-de02-403a-a9d1-88ed03a9c76b">These Waveform Library Entry Descriptors apply to the WAVEFORM in Row 1 and override descriptors in Row 3 of <xref linkend="sect_TID_3754" xrefstyle="select: labelnumber nopage"/> in case of conflict.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3756" status="3" xml:id="sect_TID_3756">
                <title>Waveform Library Entry Descriptors</title>
                <para xml:id="para_e203061b-4a2f-4fc8-9854-b764cc1ce127">This Template contains selected attributes for a waveform or a group of waveforms. The descriptive information may be copied from the waveforms or derived.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_c573a750-924a-43d0-8268-8463751014bb">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_7cc66262-2804-4aa6-8c0f-3bfdaba555d1">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_435fc714-875e-476a-b650-58c2d9fd0f0d">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3756" rules="all" xml:id="table_TID_3756">
                    <caption>Waveform Library Entry Descriptors</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1"/>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8ea0989a-97d2-4cf6-9a85-05ab93560baf">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c2592eb7-e5ad-4e53-bcde-b81b4f12056e">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_15465228-9838-4ee8-af28-bbebb1de54d0">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2531d516-b7a7-4407-87af-e1becfcba1ce">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0c0e5677-97ae-4ffb-b7b6-ec0c4ecbfad0">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bfba0dc4-3b66-4407-aade-71996095b929">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cd827a85-6851-4974-9703-bbfacf4a38a9">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73411afa-f78a-4bf2-80fc-b83794339c3d">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>

                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf44e328-c23f-4c8c-9884-3a54417da5db">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a856a60f-4889-4725-913d-8b6125f801be">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_449fdb36-0d67-4042-9908-ea3ce4e873bd">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_951ab2dc-746e-4c9c-ad9d-06f11e54b566">EV <link linkend="DCM_121139" xrefstyle="select: nopage">(121139, DCM, "Modality")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_92a0075b-1818-4cbd-8209-f85138b9d369">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_226145d8-a7c7-4dcd-b21d-324b032790db">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_528441a6-d2e0-4788-9ec1-95481effb8c8">D<xref linkend="sect_CID_29" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2766aff4-5a43-4ba7-861c-f5b9864583e0">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3374f91-dfcb-4b88-a1e2-f4c5be9434b6">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05d7bbb8-66c6-44ee-a675-2ed8b74b574d">DATE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ade959a5-5543-4875-abb2-5aed527ae0c7">EV <link linkend="DCM_111060" xrefstyle="select: nopage">(111060, DCM, "Study Date")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d89325d6-029d-45f4-86e4-61fe8e53e190">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9e65c4f5-255b-4266-9d99-a75ba6ef68ec">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_653c799d-c044-46fc-8e8f-2b9dce23c6c0">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9af84fac-27f0-46aa-ab13-0b20c8ecc1a7">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69e27d24-81d6-4425-afa1-2fe18b84987a">TIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d4154f25-cbb2-474c-8483-8118cf2dfbe2">EV <link linkend="DCM_111061" xrefstyle="select: nopage">(111061, DCM, "Study Time")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f8145c60-7222-41fc-9790-700d40952e29">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3bed9e23-ac51-42a7-9073-42dc403a8aae">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d28d7f5-19bc-4681-970e-afea9f91e675">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0c76780b-58a5-4eef-906b-9e650dfeec09">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a71f704a-8096-4763-9f2a-7065c80b4047">DATE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4d3b346-5a83-4795-adf1-c8ede1992749">EV <link linkend="DCM_111018" xrefstyle="select: nopage">(111018, DCM, "Content Date")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ed7d854-3cbb-4aad-b4d7-19daffc62621">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_61811fff-02ad-4a62-8460-afc44c13657f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba73eabd-27da-4326-9143-838e74766b8e">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1162cdef-c4af-4f1a-9b99-7546c293e3b1">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d9f165d-72bf-4400-a13e-18513fbf0add">TIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79ebb63f-1a3c-4868-bc0c-7197f0800011">EV <link linkend="DCM_111019" xrefstyle="select: nopage">(111019, DCM, "Content Time")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2ab46999-48b2-4c42-bb1e-6f8d4d25c12b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7cbf0446-ae24-4907-b77b-122ee0ed60bf">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c88279a5-9c12-494e-8a63-214e3b0cb55f">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9dcf0855-f1db-4ea6-af1f-650a0998f8ee">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43bf8bcf-27ca-4e8c-8ec4-818dc2d4c559">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b9a778c-fdc9-4fa7-89c8-e76caf7b0807">EV <link linkend="DCM_130884" xrefstyle="select: nopage">
                                        <link linkend="DCM_130884" xrefstyle="select: nopage">(130884, DCM, "Acquisition DateTime")</link>
                                    </link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_951ab49e-b18e-4908-bee2-0967c9bd5ef1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cff852e7-b0ca-41d6-9869-7094341c1ed8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c40e592a-d147-4c86-86ef-538bbc9e07b4">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9c6cae8-c368-4c0f-85cb-82c49c513007">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a29cd7d-6615-4c98-a8c1-9b86470f6249">UIDREF</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae3f5cd3-4a6c-4e9e-b03e-900bd6bd15e6">EV <link linkend="DCM_130885" xrefstyle="select: nopage">(130885, DCM, "Synchronization Frame of Reference UID")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b01ca17-aa9d-4895-bece-8b0514dcf5ed">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2c6982df-2981-4f4f-a2b2-a675a1e7b549">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e716f290-abe2-473d-a000-b233eefe68a3">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2d9d5670-dc65-43b0-ba9c-df0b7da5743a">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b1c69e0-4bb9-43a2-97ce-8a01dabc238e">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b298d66-8887-4e30-b480-f82892f1ff7e">D<xref linkend="sect_TID_3757" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e42c011f-a646-46cd-a43e-d4f0d339d2a0">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_35930da5-5351-4b66-8029-d07a02189818">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3757" status="3" xml:id="sect_TID_3757">
                <title>Waveform Library Entry Multiplex Group Descriptors</title>
                <para xml:id="para_1f6aa0e5-6997-41a4-82a8-b97d8c30f50f">This Template contains selected attributes for a waveform multiplex group within a waveform object or a group of waveform objects. The descriptive information may be copied from the waveform objects or derived.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4e391dcf-8643-4949-b771-3f3d07dba8b2">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_09d270ad-2ef7-4091-a40d-8ddc1f601c8c">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_09619a89-e6bb-4f89-9536-ca23f09e670a">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3757" rules="all" xml:id="table_TID_3757">
                    <caption>Waveform Library Entry Multiplex Group Descriptors</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1"/>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a6519b01-825d-4424-8cdb-42d83ece8bfd">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_541ddf2c-7fe4-4d39-a89b-6b21f3b44373">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3e96353a-d193-4ffa-a55e-c1527be09912">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f68e005a-e49f-4724-822c-de1f2e7ba2e2">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6a36dec4-356d-4b77-9c7b-b3016d507d6b">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5586d9ae-f6c0-4898-a7e9-7fb3bcbc664b">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ee62f3b5-1ffe-4165-9a9a-c38ad668fe65">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_68f916a2-a95c-4945-9e94-cd6d3c45a8d6">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>

                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a17c95d-b8b8-4609-91b9-5e40456e421b">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2035aac1-6af9-47e0-98cc-16f2c14ac6f7">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86ffb0f2-f207-41d7-a2cd-cad5d3a90cd5">EV <link linkend="DCM_130879" xrefstyle="select: nopage">(130879, DCM, "Waveform Library Entry Multiplex Group Descriptors")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_af20d4c4-df48-4fcf-b184-31388222c822">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f37b4420-ef10-45aa-bfea-d9f0366715d7">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a424e63-2e35-4986-97f6-758a7d34a2b0">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4240c9dc-9076-4efb-a314-4e040c151898">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8995d34d-6eb1-433e-bb4c-f3cc07c4ce86">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_181f9ac4-21ba-43ce-9074-46ac8f231736">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_affbd37f-c43c-4278-b14b-af4f81945443">EV <link linkend="DCM_130880" xrefstyle="select: nopage">(130880, DCM, "Multiplex Group Number")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_203a6545-d96e-44fd-a58a-cb1a68f9f406">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bb37ce2c-a5d8-40e8-a1d3-af4f1bc830a3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e3b10de-be0b-4f0a-b6e6-7c5b131d7eca">UNITS = (1, UCUM, "no units")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91826a31-32bd-4215-8a1e-6a4c6f3785ec">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8452b5d7-4a6d-4d94-a77f-52e7f28b0828">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38a3c01a-c148-452e-aba2-709055833532">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ddb4b129-f07b-45a7-98b3-0641d9598bf5">UIDREF</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_389534ea-1442-4416-8eeb-d220112a4b60">EV <link linkend="DCM_130881" xrefstyle="select: nopage">(130881, DCM, "Multiplex Group UID")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f874292c-db8c-459d-b456-4f3e05e295aa">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fe3d3cec-399a-4dea-9fef-18645646fd9c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_28ce1262-0ae5-4778-9aaa-8f2b64c1db66">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f26b433-d02c-4e7b-a723-8127f2a4cf79">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_137b2b14-57f3-4e91-a26a-b6a14c81a3c7">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad0b31c0-0be4-44ee-9922-577058da78dd">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ece31bda-551c-48ed-a42d-4dff19b202ec">EV <link linkend="DCM_130882" xrefstyle="select: nopage">(130882, DCM, "Sampling Frequency")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f48e034-e619-40c0-9b9b-7a639a783a73">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d76074d5-483f-449c-a491-a57b26ffcee4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48eeae99-b36f-4e62-87bc-48206c4912b1">UNITS = (Hz, UCUM, "Hz")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1587497e-f68d-4b79-97b9-051e990bc90e">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8471e0e3-55ca-4167-8d5d-6e5af7caef89">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0caaffae-f7f8-4812-8d2c-89659774304e">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84f6e18b-b442-4eb5-b951-86a8313263bb">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9d587ac-8902-4829-991d-f0c6107db469">EV <link linkend="DCM_130883" xrefstyle="select: nopage">(130883, DCM, "Number of Channels")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_93da28f3-2a27-4459-81cb-0e1ff10d9fcb">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8d248a7e-2e10-49a2-bacf-41a1b40ccf0f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_900977fc-6c36-41cb-b8d5-bb8b33574db4">UNITS = EV ({channels}, UCUM, "channels")</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
        </section>
        <section label="Cath Lab Clinical Report Templates" status="2" xml:id="sect_CathLabClinicalReportTemplates">
            <title/>
            <para xml:id="para_ba5dc641-6690-4ea0-8b95-2ea9266153d6">The Templates that comprise the Cardiac Catheterization Report are interconnected as shown in <xref linkend="figure_A-7" xrefstyle="select: label nopage"/>.</para>
            <para xml:id="para_78bdc11c-dcae-4bb9-b6be-a61c952fa2a6">
                <figure label="A-7" pgwide="1" xml:id="figure_A-7">
                    <title>Cardiac Catheterization Report Template Hierarchy</title>
                    <mediaobject>
                        <imageobject>
                            <imagedata fileref="figures/PS3.16_A-7.svg"/>
                        </imageobject>
                    </mediaobject>
                </figure>
            </para>
            <note>
                <para xml:id="para_6aff2691-d1fe-4a64-8b16-0b9806e5292e">
                    <xref linkend="figure_A-7" xrefstyle="select: label nopage"/> shows the relationship of Templates; it does not show the structural hierarchy of Content Items in the IOD.</para>
            </note>
            <section label="TID 3800" status="3" xml:id="sect_TID_3800">
                <title>Cardiac Catheterization Report</title>
                <para xml:id="para_f0b73963-3a13-415e-a7ec-e3e3a8c9b912">The Cardiac Catheterization Report provides the overall clinical results of the catheterization procedure and interventions. In many cases, more detailed information is optionally available in other reports (Hemodynamic Measurements, Procedure Log, etc.). That information is collected and summarized here (and referenced when available).</para>
                <para xml:id="para_f271e181-8c0c-4a9c-aee3-28c2e9a29ad0">When a Discharge Summary section (Row 12) is included, this report Template covers the full set of information required for submission to the ACC NCDR™ (version 2.0) registry.</para>
                <note>
                    <orderedlist>
                        <listitem>
                            <para xml:id="para_6224b70b-44e1-4d7e-bbfc-fda4a504604f">The information required for such a submission must sometimes be reformatted from a single concept in these Templates to two data elements for the registry, or vice versa.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_81b3dfed-2468-420c-bf91-cd7b3020973b">This Template is expected to be used with the Basic Text SR or Enhanced SR IOD.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_141f69ca-bf36-4924-93e7-3b703307531a">This Cardiac Catheterization Report Template is a baseline Template within these SOP Classes that may be replaced;
                                it is therefore in no sense binding for exchange of this type of report.
                                It is solely an example of a possible encoding of the Cardiac Catheterization Report.</para>
                        </listitem>
                    </orderedlist>
                </note>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_a54836dd-7954-46fb-8e6a-185bdc17db19">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_75aca6e8-e543-4bff-a2a7-c6e8705fb386">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_7a4d14b3-463a-4de5-8b1a-218bbe3b8c69">
                                <emphasis role="bold">Yes</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3800" rules="all" xml:id="table_TID_3800">
                    <caption>Cardiac Catheterization Report</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cde0e545-cadb-4865-a027-77b1113b66fd"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4c3706a0-0155-47d2-910d-74fef80800f5">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_998b128e-099d-4525-80d4-67512c0ec8e5">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8a3e60bc-a0f0-46c0-8ff6-a317dcf62fa3">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6a841266-2b44-4f04-9d7a-7d31362a097c">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dad6315e-b237-4215-b522-a935fddab746">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4516ccb8-d662-4b30-a3eb-040ae1992615">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b8680641-e932-410d-bd04-3638e49b1b05">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ee42987e-865f-4389-854d-d6b8410d29ad">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4688576e-f456-4124-8193-ced273c3d604">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4d95286-4c95-40ae-be31-1f24462fd5b1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98b6e26c-4a5b-4734-b3af-6ace5efa2f7b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00bd21cb-3542-407c-9a19-8ccc38f2f890">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1203b543-b0f5-4dc0-b72a-93508e2f5b8d">EV <link xl:href="http://loinc.org/18745-0/" xl:show="new">(18745-0, LN, "Cardiac Catheterization Report")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d2c21da1-6931-4c8f-b6b5-db7215c06022">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f62a4c6b-62cd-425e-8291-eeaf24b02a43">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4112ce3d-ec56-4ecd-9701-e16fbae051f1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_649f20e2-a9fb-4411-bb94-fe3920bb8b0b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42155b47-dc7e-403e-8c02-d0506bfd1c41">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7d445d1-005f-416c-9d5c-33c69f8079af">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_abdcd881-eef1-4ad8-a870-39d6da0f9390">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b38e6122-01d2-45fe-a8f5-121ec5391057">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf8c7f9a-3dba-4ead-85f6-e820a67e86af">EV <link linkend="DCM_121058" xrefstyle="select: nopage">(121058, DCM, "Procedure reported")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_015836f5-8691-4d5b-b3cc-408093d4c175">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c6a90412-2eca-4119-9dc1-b3527afb40c8">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b093ced-1f1b-4812-9022-7e1ccb6e793d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cbdc1b5b-a9b9-4c86-b3bd-b371a4af4e20">B<xref linkend="sect_CID_3739" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d5d3130-1feb-4b74-8492-4b1ea90d7783">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7616ffd3-ef72-4277-91e6-dc6c822b0df5">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9815598f-b288-438a-ba8f-09723b408850">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_086824e7-4684-41c5-84e5-82afc5180992">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d70580b-376e-4f95-aa32-95518585b134">D<xref linkend="sect_TID_1204" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6635fc7a-933d-4644-b188-e7b0a0eea000">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_20073b21-04e4-4646-b276-dae2373fdd12">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c411cdf-7c54-4c30-9965-331ab70ba4e0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b7f916c-0f7b-424e-8ef2-df2591258b56"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_47467b94-8e91-44d3-abef-5adb8e52c562">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e1789b43-bb5a-43cc-a4a3-742c505671da">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2b79998-2463-4821-94ba-13a199df3214"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c8af4ba-a3e3-4197-ae9a-42290e9a6558">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df5db9a2-f237-475a-a0cf-136c93ff1321">D<xref linkend="sect_TID_3601" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2e394384-4310-4b7c-9e27-2d5d303aa9df">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_954a8ce1-4b67-46be-ae0a-493853ffa051">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_507ca88a-b6c9-4ee3-a939-3855fbf78e4b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5520599-ba20-4a18-847f-9c983f9ca8e7"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc3eda5c-a187-4026-a33b-3db09ec35d0b">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fea6786e-2031-4817-8b34-ad47f4181121">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97528cfc-beaa-475d-bae6-64cd5ec15082">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f218ea6b-2b94-4fc5-a72f-1f30ddec3f01">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8cd03f04-471d-4ab1-a2c1-23ae4c1c368d">D<xref linkend="sect_TID_3802" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_88572bd4-8488-4856-8553-fae70fa5b414">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a5815de7-6688-4cd8-b728-911a08aa41d7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6371c331-0524-4678-bed4-83ede90bf651"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2420777e-3c53-4a60-9da9-4ce2f6086b29"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_071602ee-287f-40c0-9984-daa56b1183ae">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c6787f4-9a56-4ef2-ab22-740932dc0250">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0cdfc2fd-4982-4bf9-84ed-f5b7fa954ae1">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d60906e3-3500-43a5-9b69-29bd566ecdb1">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8d5b9f9-0c75-4923-bb4a-13e5e19ad71f">D<xref linkend="sect_TID_3803" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f303c6b2-02c8-49d4-bb39-c3ac960b9c80">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_baa716a9-e252-4b8b-aad4-04580e5f6b1c">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1385c255-cc7e-4d2e-bb6e-2482531e3e5e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8bc1c99e-f401-41cb-9be4-ddfb7a7150f7"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96369368-54c3-44bb-b2f9-53c094474129">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2bfccda-69c9-4ae8-af44-6c4e89df4b4e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8963d5a7-0a21-41f0-afa9-96a4af83b19f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af860901-5be3-42d5-9088-bed2adf538c2">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e9c5a1e-44d9-4c0b-a207-0a803c19b6b1">D<xref linkend="sect_TID_3806" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e4233069-4747-476a-a614-227843da0474">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f4c60a2a-bb95-4b97-987c-2143477697f2">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ebb4fbc-38f0-4873-94cf-079bffe36b46"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb9ebb99-eb28-48ce-80d3-f4b7ea348951"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0fa58ff4-8b47-4cd9-b7a6-f86824e07f24">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eed433c2-2369-4419-9e20-564d77fa5603">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c6144996-d2f4-4b66-a4ec-509ca5eddbb5">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_45d566c3-68dd-485b-ba07-07b98673468f">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de110f02-7ec2-4d53-b644-1122680f00f9">D<xref linkend="sect_TID_3810" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_47332f46-577a-46a6-8cbb-ab9d1b3084c9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aef61754-d6d9-4e0e-aefb-85af1bb3cdd8">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6af7854-b86d-4f80-b66c-5787c0462270"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3cc8e30e-ca64-45f9-a66b-00585215511b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e077ca30-c42c-4bfe-95e6-bd76c4ed520c">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc282670-6c1c-4ac3-8743-170a048b652e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_085811ff-f40b-4496-9781-fc8fe1157ce4">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f233b09-a1f2-40cd-8f0c-e0588a56a10c">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e6b1f01-c13f-4869-a80d-6a09c5b1811f">D<xref linkend="sect_TID_3807" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f6fe3ce5-524d-43a4-aa45-fa0919082477">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7106ebef-d2bb-4997-bc7e-1864cd8b2652">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7dd5dc23-7f0b-4759-8a7a-9b86d30697d5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9de07c07-040d-415e-974c-18a93f1281cd"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1d8cdcc-81ad-496d-843a-fb143a5dafbb">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b74f2676-d3cb-4aef-be99-a1bdcdb9cf29">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85ece466-8364-4c62-a291-4c4a9413eae1">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43b6143b-d986-48bd-a511-c43606871165">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc37f305-a8bd-48e6-9faf-22504c77844e">D<xref linkend="sect_TID_3809" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c9a06ae7-f554-4050-b7f4-ee17ea4e5891">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0fb9490a-c9d3-4416-a753-ee015506b239">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24b3ebe3-481a-45e2-9940-dc803ca70b4f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7416b5f-4d60-4644-b7f6-f027e22e13ca"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0247537-4225-463b-b928-39a339cd019c">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c615b66-6b60-4523-896c-4eb1a8467a96">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3530b787-dd83-4558-93d4-7e31cbc67b9e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_15f5d8dc-395d-40e0-b3c8-977799cf8cb4">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f85958d-80a4-4c67-b260-570d78c97a81">D<xref linkend="sect_TID_3820" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7d9ecfd7-b796-48cc-b451-184c1935b425">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c1bd1e86-5660-43ee-a330-fd05d767ebeb">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_698f4e62-f57c-49f4-bebd-1573f8daa8b6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_530f9092-5b05-40c4-8ecd-32bd7df0a0f6"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7839ff35-23ae-4081-952e-1cf93a536ad4">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1f036b7-2359-4643-8780-620b1e08660f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_080032d1-7701-4947-98a7-bf54471645fb">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8277dd77-0440-4749-8b89-8e36143c266c">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f055f720-ccac-4f5a-96a9-631384f498c3">D<xref linkend="sect_TID_3824" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_afc9195c-1690-47cf-a58a-dd9e9eb3a97f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_98c2e191-163f-478a-b819-adde4ff26dd9">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d6a899d-d579-4436-992c-49c2b454e60d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b44e25e-dd85-4cde-9505-b297b9aedec0"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_463bb4b7-c864-4b52-8fee-08c4f2e8feff">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd4d1345-22fb-4a33-a529-b205065ef772">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e03e0764-f144-4bde-940e-a81cd2b9b33f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0aa00c45-ae83-4f69-93a5-3962b45110bf">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a92e6e9-d081-4299-bbd8-dd4dadb162da">D<xref linkend="sect_TID_3828" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d2849691-7ecc-41d6-bc92-641d4aa773b6">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_30e93e13-924d-4e82-bc83-2c433b1ac67a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b0b46b0-9861-45da-9ba7-84fac1f33dbd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_76c5b05d-4548-4d13-925d-d6cc4d32fe08"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3802" status="3" xml:id="sect_TID_3802">
                <title>Cardiovascular Patient History</title>
                <para xml:id="para_3a96f146-efd0-4e0e-9f10-05f177f3ba54">This Template contains information about a cardiovascular patient's past medical history that is relevant for the interpretation of the SR document of which it is part. This information is considered to have some degree of "persistence" across different episodes of care.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_d9e828bf-b71d-4e91-b4cf-7fc71594a54b">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_06b572ff-1b17-4039-aa70-2d274b3df3f3">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_38fdc77c-e6b5-43dd-8cf8-585be1804bb5">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3802" rules="all" xml:id="table_TID_3802">
                    <caption>Cardiovascular Patient History</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_31fccaa6-dd0c-43ec-b73f-427c5020ac82"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_51ab3f86-8706-4d37-b77b-bff16593f525">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_92618907-7424-4095-9959-173d724c949b">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_001d4a59-573d-4925-b668-78e92d91d292">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a9737d86-b069-416e-8f03-edb4b4fab78d">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_74a89ca0-6488-4b95-980b-c9f4cb98aa66">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c469d49b-ad1b-4bef-a034-d1d634237780">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8a4b1410-ee91-4c1c-b490-a5aeabdba39c">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1dfa9292-9aae-4504-9da6-04d1ce006e43">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_68f1bee6-0960-49db-ad8e-ecf231f4a766">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9c9efbb-c92f-42f4-9c33-cb44b8543396"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb77a4af-8bfa-4973-b2ec-5da0a7d0516c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf8cf666-08dc-4e7d-bf13-8a146e2dd363">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4375120b-622f-4dcb-8a1f-f5aa8c0a34e6">EV <link xl:href="http://loinc.org/11329-0/" xl:show="new">(11329-0, LN, "History")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_83345507-fabd-4f07-b530-e3bd084eb42e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4e4334ea-7e99-40bc-9509-97ecda43d35e">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_759880a1-48f4-4473-899c-b29a3a155f60"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d60ec949-3bc9-45d3-af79-0dba1af659ef"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b72d9842-9a5e-49f6-8ff0-be80d523a578">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c56261f5-f845-4647-84d6-1847b860fd81">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d491deb-d276-4ed8-a8d4-4e373d9115bf">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b91cc27-e299-4853-bea0-d0d5a021b2e4">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1961ea04-f1ac-43f9-a42a-1819a78f3357">EV <link xl:href="http://loinc.org/11329-0/" xl:show="new">(11329-0, LN, "History")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e3265e07-fdff-4d59-9ac9-5ed7aa9f1caf">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_23df85d4-adad-45b9-a071-957b39fe1233">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8445bbe2-d524-47fa-b2d0-68a29b08ed43"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_107aefb5-3c51-4b3e-a767-9fbfeb75ef3a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3599a942-75e2-4eaf-aa8a-1134c301d0bb">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31c3f8d5-8b00-4ede-be32-3e8690297ae7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3bdec854-fe57-4d88-bd0d-509b5a6e0fc7">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_657e212f-7a0d-43a8-a83d-186a81191c96">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a11db66-08ef-4a42-b9ec-93b54f848209">DT <link xl:href="http://loinc.org/11450-4/" xl:show="new">(11450-4, LN, "Problem List")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_489e46d8-bdc1-4d8d-8e7c-4946b53f5945">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_03b2b6e3-4266-49ff-a6b3-58616f0211f1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a393eb84-e070-4bec-9ae8-af0e026b1250"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e2c339d-ffd6-48a5-acf0-339edb063164"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ae58ffe-ef12-4923-a224-e8de631617a0">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_66d1fac9-1c97-44a6-b11e-69ef81d7fb6c">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ddf4faa-c2d3-498f-986b-c635e96392c0">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b54c5b7-c219-4182-8b1b-a279f69c5aa7">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bbd4c59f-e265-4b1f-92ff-dd6994d5a542">D<xref linkend="sect_CID_3769" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f2d60c85-86c4-4ee0-b66e-987835f8b639">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1c8b17f8-9680-4d80-b21c-b1e2e7eee75b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a800ca7a-e831-48fe-a9d5-d5fe32104fcf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8dc87fce-382f-4569-86d0-7c9d0f5ddad7"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00039dd2-9aac-4301-8aa6-219b3dfeae9b">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dcf86574-1d7d-4b2b-bde8-cc919e1eac70">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_424ce61a-3728-4fc6-8e93-c61d93c0bb24">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_314bd565-36bd-46ae-802f-eca8592f5218">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c0ade11-12ac-4f03-a3db-01fa0fffb47b">D<xref linkend="sect_TID_3829" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_def2702d-8fb4-4892-8118-200458dab258">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_860cbbc8-42c2-438c-a349-58cc214cbcbb">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ba8353f-33a5-499c-9f5e-b888f0d2a2f3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_767bd1b6-e6cb-4b50-9a9a-d035f79ca2ec">$Problem = D<xref linkend="sect_CID_3756" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9fc80228-3914-4b42-b48d-3a09ad6e1840">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38885191-904b-4185-88f0-d6a93d830c28">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36a6e348-3135-4ffa-8b4b-7aa2b6f4494b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eeb2b373-8b16-4ba7-833e-acceea5b746b">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7df55c4c-1199-4891-8a16-8b94083d601f">D<xref linkend="sect_TID_3829" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_66e55f8a-9116-47e8-a10a-ccc3c404d9b4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2af898c2-ada1-4369-995c-34939ece57a4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_115037f3-e96a-4767-bb53-30fdb4867b01"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe75bc4d-c467-42e7-9251-582f2ffe23f4">$Problem = EV <link xl:href="http://snomed.info/id/161445009" xl:show="new">(161445009, SCT, "History of Diabetes mellitus")</link>
                                </para>
                                <para xml:id="para_4953dd90-e2ea-46e1-9d1b-8e0211f363ce">$Therapy = D<xref linkend="sect_CID_3722" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b14632d8-37a1-48f7-8285-ac84e1ec5a54">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c43b3ecb-4171-43b9-a232-78706ed18a19">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef311d05-8adc-4809-8282-58afc760351c">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d7ffd0c-59bf-4261-a9fe-36909c7dcb58">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21e3b519-af2c-48b6-9662-4b348cb34f3d">D<xref linkend="sect_TID_3829" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a397f932-88b9-4f0a-adba-1b844f93bd66">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7ebd956b-d14b-4daa-ab11-fdfd09b97114">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca363fe1-bc77-4988-8c38-33ed113210df"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce6ceac4-5b2c-4b14-9a15-77b999f9415d">$Problem = EV <link xl:href="http://snomed.info/id/161501007" xl:show="new">(161501007, SCT, "History of Hypertension")</link>
                                </para>
                                <para xml:id="para_6dcf1228-a14c-4db1-97e5-d4041e193c60">$Therapy = D<xref linkend="sect_CID_3760" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3abb4940-e4e2-4b80-a2f5-67d979116b3c">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2688de6-7049-4b8f-b6ca-ce79eae6b91f">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1dcc880a-086f-438f-867c-a6a5b76f24b1">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81a134b5-63d5-4919-ac51-2f9b6511f9d1">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df5c7d2f-1df7-4d50-aa0b-8026dacc7382">D<xref linkend="sect_TID_3829" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8276630e-7e9d-4a44-8a35-af0c5e5c41b2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_98bf26e4-e178-4c16-af8a-e2f3ccf5d2b2">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_15ade764-c81d-4658-bf9a-c868290747b2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_60e336e6-c277-499b-af1c-6b72e2e08217">$Problem = EV <link xl:href="http://snomed.info/id/414416008" xl:show="new">(414416008, SCT, "History of Hypercholesterolemia")</link>
                                </para>
                                <para xml:id="para_0d46c967-370c-462f-ad39-123a5ca7eff6">$Therapy = D<xref linkend="sect_CID_3761" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72a1766f-e591-48d4-9d8e-5e8bbede69fc">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc50eba3-2e3e-4bfc-b275-9f52de58cb81">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc382fbf-7562-4a58-971c-c7f3a48097d7">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_332d496e-185a-445f-84e6-a324f5bb3590">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2f195c4-be2b-4108-80fb-07b2118d2f2c">D<xref linkend="sect_TID_3829" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_962813d9-c5e5-426f-b164-2aae9303d486">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f3a3bf1f-db0f-497a-aa3e-655b0e11938a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b097b1d4-1a0a-4b39-8294-7aa1e98fd099"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a84403c8-d38d-4928-8611-984275fa6ae4">$Problem = EV <link xl:href="http://snomed.info/id/44808001" xl:show="new">(44808001, SCT, "Arrhythmia")</link>
                                </para>
                                <para xml:id="para_fcfde2f9-453e-4eae-9527-3b5eed9e9837">$Therapy = D<xref linkend="sect_CID_3762" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad1ea16c-40db-4667-94d3-2908d4766f2f">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c28ceda2-1898-4b8c-b5f8-504db952baea">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b300dfa-65dd-4275-8a96-078fd7051698">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b05baa5-5878-4c82-8693-2893bf7211ab">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab6331ec-bdff-4e21-a3f7-0f6b4f174927">D<xref linkend="sect_TID_3829" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_050372a1-142e-494e-81c1-0186f6a82d00">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c46589be-3135-4a1b-87cf-a5c064fe1311">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25c23da9-70cd-4f8e-931c-e423cf994e01"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7cfe5558-db26-44fa-8fb8-62a85106f1a3">$Problem = EV <link xl:href="http://snomed.info/id/399211009" xl:show="new">(399211009, SCT, "History of Myocardial infarction")</link>
                                </para>
                                <para xml:id="para_f3969fad-d3f1-42e7-8c56-3c910ad53dc6">$ModType = DT <link linkend="DCM_122170" xrefstyle="select: nopage">(122170, DCM, "Type of Myocardial Infarction")</link>
                                </para>
                                <para xml:id="para_1de885ff-e7b4-47de-9c3d-8f89e03170f8">$ModValue = D<xref linkend="sect_CID_3723" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_7f560701-f766-4c95-9bad-b104a8ca576a">$Therapy = D<xref linkend="sect_CID_3764" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99b735ce-cf8d-4c12-8980-be64311f1e85">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e8407382-3cb3-420d-b393-447977273922">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46e83437-d072-49ab-9204-44e6757f4095">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f1da252-30a9-4a75-b9fd-144bf4595959">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0eed9b1-65e8-4e3b-901b-c0d426e1cd74">D<xref linkend="sect_TID_3829" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f168d502-893d-4f64-bf70-741330b97755">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5f4e514c-c0a7-4a61-9d18-a6d99b2186d7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5041dac9-deed-4033-a619-c51670bd50e5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c9f6ff0b-6ed2-4fdb-bd63-3d780299dc0e">$Problem = EV <link xl:href="http://snomed.info/id/275552000" xl:show="new">(275552000, SCT, "History of Kidney disease")</link>
                                </para>
                                <para xml:id="para_8cdd9994-af91-4698-b2e1-d5d7f67a3b8e">$Stage = D<xref linkend="sect_CID_3778" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_213dcab0-775d-4273-b3d3-c887fd8a3cad">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b586506-a03b-48c1-817f-e96e6b297bf3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87029194-b489-47e6-b547-6ec31cfbc9e7">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_41a918a7-5946-42d8-9446-e3195101dce3">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c28f1b1-75bb-4109-8d26-700f507c4b6c">DT <link xl:href="http://loinc.org/29762-2/" xl:show="new">(29762-2, LN, "Social History")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ceb3f438-7dd9-4b1f-8482-56d87c47467e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e895b005-ea2f-43b9-acaf-05ec6263d4b5">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_488e0a87-8b9a-4719-b77a-6b7db26eae65"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de30479a-fba2-4620-bcd1-d253f9c91118"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca1e7389-c8be-4fec-992e-40babe6689f3">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b8206b18-03f2-4d34-9978-beefc9bb2dac">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4e57617-26e1-43c6-a676-9e2ae19a3376">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06a0ddad-ccf3-492b-894c-24da780f079b">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_942feaeb-46a5-4b39-8982-03ae0d6ee168">EV <link xl:href="http://snomed.info/id/160476009" xl:show="new">(160476009, SCT, "Social History")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b3ce942-e29a-402b-b1e1-29c8c3436625">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_140bc80a-d31c-45f8-8678-1b8828543a34">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_567c68a1-9002-4472-b28f-963766e1bf28"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ced2ed3-5f71-4c80-8a16-abc4078497ae"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ace7c4fc-18b0-4c5d-b460-a85aa6a67e6c">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ab79ea3-fe6a-43db-9e31-89705f30cd31">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bcfaee07-a3c3-4856-9561-cd7e1c5feab6">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b9f4254-b62e-4c65-8c6e-23a749bc61c2">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d2acef4c-6bfa-48b1-8b47-5d761e68e1c4">D<xref linkend="sect_CID_3774" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f11d89c1-0d5c-44fc-8d6c-2fded2e5097e">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fafd41d2-c345-4bfb-b470-ff586c45d958">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef133c9f-3713-40d8-9d3d-415d0e9fd820"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_928e31bc-196e-42ed-b2b8-0ccdacb1e9ab"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e9c0a03-f719-4c13-99b3-cf16aada267d">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_815bf546-6df5-4970-97db-71bf9c399273">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c6ddc173-be79-4294-aed6-9192c2ca591f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f252923-ce5a-46ed-882d-5cd3ab1a2120">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a863e2e0-f227-4744-b73a-bf4bef56dc72">EV <link xl:href="http://snomed.info/id/365981007" xl:show="new">(365981007, SCT, "Tobacco Smoking Behavior")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_08ac50c1-129e-415a-8e69-412aa46edb32">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_beeb45c6-9dec-40b6-8864-db98ca51a777">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d2b5a567-09bf-45ff-a97e-a01dd157ec69"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72b5990a-cd57-4e63-a8c6-8c7f79c826fb">D<xref linkend="sect_CID_3724" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0a9f8f4-77ed-4a15-bde4-824a2c0659cc">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1decc13-afe6-451b-bacd-c0f7b9fb3c13">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e47554d-840d-4280-b960-dbe5d9fae459">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92ead679-6ad1-41f2-b830-338607e0792d">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7649809-e2b9-4275-8df7-d0e8db4f5b0a">DT <link xl:href="http://snomed.info/id/228366006" xl:show="new">(228366006, SCT, "Drug misuse behavior")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_177ca9d3-fc5f-4863-9f58-f4b8beae37c2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_53053c8b-b52d-4ec4-8c7e-d0a9fd14a5cb">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc031dd2-7ba0-406f-b168-a119a8a7a66f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8113a901-b363-4a6b-86aa-98e1e70fe27d">DT <link xl:href="http://snomed.info/id/78267003" xl:show="new">(78267003, SCT, "Cocaine Abuse")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43a668a0-80ae-458d-8a91-f7ce81aa3fd2">17</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d53b6e4-605b-4aa9-b0fa-a5e5e30b3596">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e28ffc90-e8d4-461c-8873-0b532112a5e3">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_66108517-2b93-40f4-b2c8-98f619a1d7d5">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f19121a-2894-4860-af14-effe85b52c18">DT <link xl:href="http://loinc.org/10167-5/" xl:show="new">(10167-5, LN, "Past Surgical History")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_431f973a-75e7-45cb-a39e-2f35274ae12d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_acd05213-66d5-49ee-8ddb-2aa265110952">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9133bae7-a54b-40dd-8c51-cbe0283d7eec"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91c61521-95e7-440f-80ac-6af69da4a114"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_23524415-9723-4e8d-a24a-5fe916f3458d">18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c58900e-2573-4da0-9ae1-71e836a42073">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36f88e80-8efe-477f-9449-fb8473f61b3b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b96bf6b7-25a0-4447-be9a-840616489388">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_168b248a-4fc9-4041-bcc3-e2d34e5b0262">EV <link xl:href="http://loinc.org/11329-0/" xl:show="new">(11329-0, LN, "History")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_813032b0-76ea-44ad-a697-ca0a96ceed40">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_08bce6b4-87c8-45d2-90a6-6bf62e3d5a5e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9394d33-7e96-4dc6-a930-3dcd09a87eb5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1590de38-8fd1-4239-9ce5-e9d2ae1004a7"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6840b85c-31a0-40c4-b9ec-5e0b23977cf2">19</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55c6dd28-5037-49cd-a72c-91d7bb0998e4">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d5fe87f-82e3-4b3b-ac9d-a16bd2c81922">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a872228e-78e7-4f67-b929-6d0bab1e8b26">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_40ebeb10-06e6-4d9a-8d7b-70b69c9ae276">D<xref linkend="sect_TID_3830" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c8321dcf-8bab-4ce6-b180-ac4663f9fba4">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1549eea2-78a2-41b6-b504-c407aef5eb23">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e27108f4-f28e-485d-a4ea-a56c5261c534"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e43cea43-5843-45c7-9126-0d5b82ea7b86">$ProcType = DT <link xl:href="http://snomed.info/id/387713003" xl:show="new">(387713003, SCT, "Surgical Procedure")</link>
                                </para>
                                <para xml:id="para_a46a43f9-c131-4641-b655-c61f5ec77c81">$Procedure = D<xref linkend="sect_CID_3721" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ebaf00ca-b71c-4977-99da-0ffcc3dd3bb3">20</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf182e5e-29df-4431-bba6-77eb7b68e361">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06c08f15-0dd3-43d7-812f-4564ddcd08c7">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e893ade5-a0eb-4969-bf7a-018b00033e60">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee5cd685-a4d5-4037-bd2b-f6b2ceb96c9d">DT <link xl:href="http://loinc.org/30954-2/" xl:show="new">(30954-2, LN, "Relevant Diagnostic Tests and/or Laboratory Data")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a107c848-021b-4da0-bb9f-a3cef1b3752b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_857bd4bc-80fa-4702-af2c-6f740317c0fb">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97c02cf9-9f51-4d96-942d-7d6bfeddffde"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1878cf63-54a6-4bc2-be1b-0ef98d48bcfa"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26a85a54-3ccd-4852-94d7-8963b039bb30">21</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ea5b1f2-c3ac-4bc0-b67a-818996f3d689">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b39a5011-9cee-41a2-84c3-af9e21e47a25">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05798890-e48f-4ff1-98d3-145a3d1ffa3d">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf863f1c-1848-4be2-b1b6-96dbdbee618f">EV <link xl:href="http://loinc.org/11329-0/" xl:show="new">(11329-0, LN, "History")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b732fdf-41c4-4537-b28c-5164533ce9d9">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fe9c6e09-1322-4302-a662-6a4b55a7f0ea">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf8cfcb7-6a8b-4f7c-9e95-9dfc1b77a5bd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26ec2b96-adcd-4fc9-bbf9-c2044c18b8e2"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_143b9304-3929-4e24-af31-513af127f5d2">22</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26a7db4e-5596-4e98-9642-05bcce991c02">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b789762f-cb13-4f61-9164-c635c47f6588">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa103938-5241-4aad-8e51-d79c3dfe06b7">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7fe849c1-9d31-461e-82f1-22e48145c037">D<xref linkend="sect_TID_3830" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8055b9af-f8cd-4438-b5cc-5df69f61f23d">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6aafb542-3b7c-47e0-9625-df320452dae7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6525a474-d3ca-49ab-89b8-72c6997db204"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd46cee4-9578-4c2f-875f-369606690994">$ProcType = DT <link xl:href="http://snomed.info/id/261004008" xl:show="new">(261004008, SCT, "Diagnostic intent")</link>
                                </para>
                                <para xml:id="para_922426ec-eeb6-4ea2-acee-b5c2b5ae9251">$Procedure = D<xref linkend="sect_CID_3757" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82260faa-85cd-4ca3-bea4-705852d8ed6b">23</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec985e5f-229e-4227-a122-37b21f8ba2f3">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03cebc2d-b582-49f2-9665-cbd3581950e8">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8aaedf1-da95-4f97-863c-4af087bb0122">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3caf3412-c315-46a0-93c8-7d7c5750739c">DT <link xl:href="http://loinc.org/2085-9/" xl:show="new">(2085-9, LN, "Cholesterol.in HDL")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_351059a4-286e-4716-9b37-147fe66ca569">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f5dd3ed-8914-45e6-ac52-32a0e9bbfe45">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ab70bff-ed2b-4717-9174-bf8526da7d32"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0533d0f5-2aac-4f29-81f0-e9569113554e">UNITS = EV (mg/dl, UCUM, "mg/dl")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d80731c4-649c-4480-9e43-f301bab64c58">24</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_097b9aa1-3246-4d87-a72c-f09edc1e1d7e">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_56125bdc-d099-402e-bab9-40baec2deeb4">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_588eb432-c4b0-4dcc-8d28-64a0cbab38e0">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b813370f-ae10-4f8e-b04d-1f4d78a7ae82">DT <link xl:href="http://loinc.org/2089-1/" xl:show="new">(2089-1, LN, "Cholesterol.in LDL")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_008ee846-ea48-4e01-b617-75637060fb48">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2025e6ba-5645-479f-930c-557e59cc59d6">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_127b10a0-5184-4e48-b050-b882f438d6c5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b0e171e-bccc-4670-9328-a48e36020cb2">UNITS = EV (mg/dl, UCUM, "mg/dl")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4027435-669c-482b-885f-3635f3aa5b04">25</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75379eff-f6d4-4ffa-82ae-a4408a569477">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab6dfe9a-2805-4ff2-ba8a-aa1f181e8c63">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff45dcf4-c008-46a5-a0f8-2253557b893a">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b53cb748-de20-4526-903f-4bbe056a52df">DT <link xl:href="http://loinc.org/10160-0/" xl:show="new">(10160-0, LN, "History of Medication Use")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f7eb7b95-99a0-4fb2-b10a-68991361b795">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5624745d-6e63-4aaf-b397-6a7695f61441">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b83b35f-5472-42c1-b2e9-5f93345f8876"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2332cf1c-2a9b-422f-8305-6283a7d1a35c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02826056-499e-48f4-94f7-1d4fcdcc1adc">26</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0305bab7-fdb6-479b-bb63-689c6f385e5c">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_816e737e-cb48-47f0-84ab-493e8721511c">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d2b0d8fa-bfe3-42b1-811d-f215b68ab531">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48988cfb-b03c-4139-bc49-f3fd7fa977c0">DT <link linkend="DCM_111516" xrefstyle="select: nopage">(111516, DCM, "Medication Type")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c964a98a-3058-4407-8903-b4952c0b2b02">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_91b8fe7a-fed0-4510-bd9d-7ff0dadec8e0">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4af5bd7-8f74-4ecc-83af-a33cab1274c1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d35957a-720b-4d0a-bf17-9fbcaf0a1584"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0880b07b-0bbe-4a66-a413-1704d797f624">27</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79344ce4-d358-4744-8a6e-06c86004b222">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f583a90c-e93a-47d3-9b42-11650c10f406">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd564f34-9395-4a61-a1eb-e8777ba4cc5d">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e56c30e-6a55-4ec0-b3a2-4cb92d0cf517">DT <link xl:href="http://loinc.org/33999-4/" xl:show="new">(33999-4, LN, "Status")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_473da622-bab4-43c3-a4ed-244e0a1ef340">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0e82c07f-4392-49d3-abfa-6ca9f880fa75">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83d2a223-45e4-4a4a-9b24-c21a92749878"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_186d9794-0ef8-4c74-9872-2baa0e997431">D<xref linkend="sect_CID_3773" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aee9c7f9-a4a2-4775-9791-e6426a31f02e">28</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e7e1f96-d2c3-4b1a-bb40-d5f49b404bf7">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_573a9787-a266-408f-9541-a5cdd6bcbafd">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab2b5bc9-1630-4467-ab07-6523a716c1ea">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e4dc590-79b0-4fcf-aab7-711ae8e4fb7d">DT <link linkend="DCM_111516" xrefstyle="select: nopage">(111516, DCM, "Medication Type")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fa278df3-e214-4840-9e84-a7f0ad00a208">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0e767516-21cf-4ba9-be48-29496c4b94ba">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f438faac-ea62-4d0f-888f-7be9d4aee283"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ecd6de1a-6142-427e-bcc5-2e0916bbb333"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b43d16b6-bc1d-4862-b5ed-cf42c33a1d76">29</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6957175-21d4-4c79-aea6-41183cb7fa96">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1c92ba4-7567-48a4-b51e-d2af8eeffbad">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93a0cfd5-3b3d-4fdc-8ec3-da84507ab72b">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e8f43ed8-fbc9-4948-bdf9-676fea16f405">DT <link xl:href="http://snomed.info/id/260911001" xl:show="new">(260911001, SCT, "Dosage")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_747299b9-c7fd-46db-9d97-f54b7790a6e3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_157d8b56-b1a2-41f5-af11-a627b25a3c79">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_90e6f99f-108e-4b32-99d0-7c5a0a7d9325"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ed03c82-bbd8-49ba-a480-f8492030b008"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_108c6161-bc3f-4863-8ad7-1eee6683bd73">30</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e2f1947-433c-47d5-8d6d-ab6d006a1347">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73fd1bcf-a1ac-4d2b-99a9-b712fbea9655">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_422f98ca-5df6-42aa-b8a0-70cce515056b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a78432f2-e41d-44e5-b097-5c763e018b27">DT <link xl:href="http://loinc.org/33999-4/" xl:show="new">(33999-4, LN, "Status")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f9ad9bcf-8f07-46b7-b4ed-9fd3122f2d0d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1a17b449-040b-4df8-8530-70350eed266c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_20bf7f2a-b880-46f6-b82d-5bcb5d0c267a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb3321b5-01f3-43d5-a41e-1b8b6b20cd07">D<xref linkend="sect_CID_3773" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_01b8ceb5-2572-4fe3-b405-adc3a4ceea10">31</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a1fb6cf-0a02-482d-b661-b5adde770a66">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b851379-49ce-4145-84ab-ca559f370009">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a3fbcab-a430-4a3e-a56a-b8b4c2dba4b7">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0fb0ff9e-61e8-4dd4-90ba-9c58e7b1889d">DT <link xl:href="http://loinc.org/10157-6/" xl:show="new">(10157-6, LN, "History of Family Member Diseases")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e19206b1-4fc9-466a-bd78-165690cd1831">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_07bc2446-6370-4f06-96d9-a70415393dce">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_18a79182-2899-4464-98b7-9df5751ccf80"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05b8bb41-1487-45f3-9ccb-9012643f2c09"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5232bdc0-4774-4f62-be4d-bcaec6e87ecf">32</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ed5c8de-0bea-4e27-b4bd-1a9c635df573">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_41b8e0e5-246b-46a7-b8a3-fcad05df2902">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9211a1da-ecb2-43e2-aadd-190648893617">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5efb0c12-ca60-40fe-9eec-d98e44a3ef10">EV <link xl:href="http://loinc.org/11329-0/" xl:show="new">(11329-0, LN, "History")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f98a3f07-090b-4a88-a1f4-5f8bbf406df2">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d94c7b45-91f8-4ec6-a6d7-5ce7ba144eae">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ffccded5-53c4-4ae4-903c-c314550ff8e0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b13f6e5-e862-4c5d-94a7-abcf01a3681e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a40df9a8-d72b-4af3-9f6d-bf1ad5945522">33</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a19525e-4d39-4552-8896-6ba7882e2ec2">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_625f4482-bc27-48ef-ab46-744762bba4cd">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d73ad8c-d426-4242-a200-e4924426a9ec">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b7e3bdc-7dd2-4334-95f4-b09e88aa9e6b">EV <link xl:href="http://snomed.info/id/416471007" xl:show="new">(416471007, SCT, "Family history of clinical finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_99163d29-5056-461c-ba07-c22d0ff64182">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_45f3e780-ccca-47ad-b307-caa71c6748a0">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50803bfc-501a-44cb-ab08-bb7ac1c58727"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c55c7a1-41bf-4c3f-a860-02846175114d">D<xref linkend="sect_CID_3758" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_efd80664-7cbd-4891-8ba9-62f90fefb4b7">34</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c48a86ce-21d7-4f67-bc51-456b9f6832e8">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f321495-2ad2-4373-9572-4234567f3c88">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_260b098d-8278-4ebd-8252-d8fae82e94fa">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_89a2aa5a-e696-4156-a535-f558cbf0309c">EV <link xl:href="http://snomed.info/id/408732007" xl:show="new">(408732007, SCT, "Subject relationship")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d5ca2c00-1900-4100-bf31-c85fd89dd1a1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a55e5f9b-a78b-4428-9a64-5c3d5d1835bb">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61364d16-5223-421a-918c-a26d9e2e4f43"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dbf2ad08-6d75-4a45-b6d4-ccd2c432c50f">D<xref linkend="sect_CID_7451" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_990c88b0-10cd-44a6-91eb-760d35781678">35</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2124be22-c1dd-4173-8ae3-fa161fedd0ec">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0c895673-7c49-473b-8485-8e1fbf067fb9">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4a3a8b9-5d80-402c-8f79-0d1074aff77f">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e8c7f20c-7a3a-43c9-a48f-617353bb5006">DT <link xl:href="http://loinc.org/46264-8/" xl:show="new">(46264-8, LN, "History of medical device use")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d8fa2f64-7c30-4662-ba94-2cdc719e423f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bbee1758-8d3b-4fdd-b00d-e2b06ff0b9b4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_01768810-7a48-447c-a656-cd7946c0926c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c624cc9-6f45-4117-8266-20827a774180"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af7b49b6-6dee-4ea0-8c15-7e059adf5a0b">36</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e27ef73-0589-4ff2-bf1f-77e19343b870">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38a40957-0aa2-4eb6-9bb4-adf584b9f3af">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e457d09a-330a-4bbe-be18-6feb12402cd7">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d7f63b5-ea3d-4fda-91fc-fe8c69e9b10e">EV <link xl:href="http://loinc.org/11329-0/" xl:show="new">(11329-0, LN, "History")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c1ae50aa-f9a9-4045-aa65-83f559f3abbc">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3b91d137-f886-41b3-a681-8a4eef6fff69">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd5d5fcd-e1a5-4f0e-8267-cb292cf66a61"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_610d78f7-428d-4df8-be08-b47edad9bdc0"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b522a59-e426-4e71-9089-8772ab0d5f4f">37</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df275b61-b056-4d7b-a69f-ba776c465291">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c049867-829c-4b68-94b6-8b455a6e1f74">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f10ac1cc-312f-49ef-8581-224b3e712f13">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_56f168ac-4352-4b40-bf57-89618f53cc71">D<xref linkend="sect_TID_3831" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e142f936-c0be-48e7-84e3-5dedb0873163">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_27acf5d3-d653-4771-a392-66192aef9f85">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c488f6f-0ff7-4930-96cb-28ac2688431f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_543d18bc-d455-4ef7-943b-a4980aafcb72">$Device = D<xref linkend="sect_CID_3777" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3803" status="3" xml:id="sect_TID_3803">
                <title>Patient Presentation, Cath</title>
                <para xml:id="para_9d7d1f77-6958-43a3-b254-406927ee8747">This Template describes the aspects of the patient that are specific to this clinical presentation (admission).</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_aeb1e85b-8df7-4393-96c5-87b35fe7dbdf">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_6030f927-979e-4f1b-9665-c7a90a76080d">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_775333ed-29b6-4c52-96a2-3c5b187e66f8">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3803" rules="all" xml:id="table_TID_3803">
                    <caption>Patient Presentation, Cath</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f51fb8fa-3319-4948-bfd1-ef39cdfbdad7"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_63034f93-25ad-4552-983b-b1c01d9e211d">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1f04a5da-c3cc-4a55-95c5-83734df1b2a1">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5f362ff7-1c2d-45a6-bbdf-efa33d4c7904">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1a262830-e0ae-4fd2-9a04-0f47be3f7ee2">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_483011a8-8157-4e5d-a169-db8045cbbbf2">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_96baf651-3b6a-4df1-87e9-2e8b4fbabd80">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_46c90ed4-d63c-4844-9e98-6de0fd6e51be">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_662d176f-6136-46e7-99ce-79cc1b4c034a">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fddc7de1-9d08-49b4-8fa2-ceece8613d1a">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5e965a8-7e78-45f3-a67c-06e67287070e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d28b8502-ce95-407e-a73e-03beff7e3961"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6cfb177f-d972-47d4-8095-deee4235a54e">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_980b8bc7-5084-48bf-8d72-d2733b832461">EV <link xl:href="http://loinc.org/55108-5/" xl:show="new">(55108-5, LN, "Patient Presentation")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ce42799f-013d-4928-b3da-dfe8e5a103f8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ec246875-93af-479e-bd81-9514f0543b84">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1f875b31-a074-4f5a-81ef-53e0e58b53d6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_28d33b88-dc99-4f3f-a938-d977e59e9904"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af418dfe-1ba3-46a0-9e1b-dd6e586b366d">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91325a4c-02a5-4fb9-985d-d8596fed23f8">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6aa4af5d-4fd1-41dc-9e6d-11668971568e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c3206baa-3e79-4838-ad25-d5d939ffd93b">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70ac36b5-eb1c-4484-b92b-66663491ecc4">EV <link linkend="DCM_122128" xrefstyle="select: nopage">(122128, DCM, "Patient Transferred From")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9d44d74b-97d3-49bb-bb24-fed4a792b875">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b9b9e634-f81c-4119-b4d9-9bd7e8d13a92">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09ef399e-f7d0-441e-9a6d-00ee085206dd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30a028db-a43f-4e2d-9b51-73f14f930b53"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae781d30-965e-4ba6-889f-d86af5d474b5">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb83cb4c-95d4-482d-b849-98d6be9eb659">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a73a288b-4644-4528-9991-5a00aa37213b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38a2b88d-8a09-4c9a-b2a9-207e9c830a0d">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c79e432-5958-4b4c-9e19-a6b396d67d41">EV (15, NCDR [2.0b], "Admission DateTime")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1cdbd81b-57df-4dc7-beb3-a5c3a42010a4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7b625135-c7b0-46e8-8031-d73e7617c370">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a882f24-c943-4e8a-80f6-96e1f46f0ed1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a53c23a-7f82-4719-a816-444c645c81f2"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e0adfe82-0d78-4dde-9dc3-41aa7bcf2306">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_410b9557-db6c-411b-8c7b-3c4cef975af6">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6902748-497b-486c-91b4-325556c6eeed">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c764e01-c2bc-495f-a94b-0bb387668f69">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c0b26c0-105f-461d-b10c-d156306f482f">EV (17, NCDR [2.0b], "Admission Status")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_151c5830-fa00-4464-bbde-884f798ac1a9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_39e46356-f201-4524-b4c5-6dce4103341c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4eff27d3-da29-4276-bec4-764095456365"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d2b5550-2048-4f8a-8893-04ddec52439e">D<xref linkend="sect_CID_3729" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5fc423be-a762-49c3-b73c-1f8cf46c7d23">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c2180354-7b0c-418d-a0b4-6b3aa36514b6">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0d95947-96d9-40b6-964b-b65d0e9c3d1e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_49c4630d-7712-4bf4-95cd-e747679c5f44">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ecb2e6dd-d575-4c1a-b391-d09c8fca0538">EV (18, NCDR [2.0b], "Insurance Payor Type")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0b6123e1-49d8-4104-bf78-a6ed0eb3ec3e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_370a9fae-9cde-450f-b3e5-c0cadf83b40d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e1d52e0-74a2-4eb7-960f-6dcd6c03884e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f9a5fe5-423c-4815-9430-1301983314ad">D<xref linkend="sect_CID_3730" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2336fb86-3a40-44f4-b614-d08623fb8aa8">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85b186fc-bd2c-4dc9-810a-ef490069ae71">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed2dc23f-e7dd-4eff-8acf-ed344ce2c2da">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82f3096b-d7bc-4b6e-9865-5eea5382f47c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd3cde67-9b1a-4c72-81e6-c8f6f8b5bc1b">EV (46, NCDR [2.0b], "Congestive Heart Failure Prior to Procedure")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_50af5091-e0d6-4e69-97bc-21611bbe83a9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d1cff99e-edcd-4aa6-996e-eaa949bb263f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d7348aa6-04e5-4062-9787-21d30a7abd38"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b63aea1f-19b3-4c86-aa5e-487bfea5b838">D<xref linkend="sect_CID_230" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_393301f0-f725-4ed2-8cff-018e251b82f5">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_788ecc67-58a6-4294-b6f6-081bb75490b9">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1cf7f2b2-6431-40a8-aa78-f6a86420574b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73d3623a-2a2d-4b33-8774-03c94ea3740c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9981091-5403-49af-9718-4fab321e7f5b">EV (47, NCDR [2.0b], "NYHA Classification")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_231a997c-b83b-4743-82ab-36a79869a4d5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_98dbf8f1-5f2d-4b64-8c81-0a4fe731b157">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8c0f516-d2fe-413d-8a00-97563ef4fffe">IFF Row 6 Value code meaning is &lt;yes&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4aa40eb3-a895-4a74-96bc-aef81c0b0bcc">D<xref linkend="sect_CID_3736" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7d32c14-7717-4de2-8865-055f5ff93ebf">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0ab5263-f06b-4136-91d1-de066bff4388">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd5f6f06-ca20-46df-b1d9-056e52eea4d1">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8184a93d-ae13-4e3c-b0e3-dfa7865f523a">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa3733f0-aed0-4bd9-b27b-f77d56a64e57">EV (48, NCDR [2.0b], "Noninvasive Testing - Ischemia")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3869c22e-d2cd-4164-8749-23bbe436be4d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_55432630-b1f7-45ef-b733-339efd6dc9bc">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9af70281-56de-429b-af39-3d205655c640"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cad6b489-df8c-4d3f-943f-3f2718feef38">D<xref linkend="sect_CID_3737" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4eddd169-b138-4564-b5fd-b3437e3eddbc">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c31e059e-2402-4776-a18c-35ff63149d37">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7075e90-ac57-49e4-a850-13e4dc26c447">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c17f9a42-464f-42e1-8056-8d5446bbebe1">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4457b3c7-411d-482f-a9c7-d9fe343c5faf">EV (49, NCDR [2.0b], "Pre-Cath Angina Type")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_02840936-b9c0-46cc-b689-72bf28fe071a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_03af18f7-cdf4-49ab-adbc-48bb23455d88">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7aad8a1-00fc-41dd-9c4a-0e63de5eaa67"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85bed1b7-0e60-413b-b257-91dc5c4c9192">D<xref linkend="sect_CID_3738" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09a1480d-2966-4896-a7ae-091725b0e6ab">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da03cd40-5c42-498c-bbe0-95d8ad4843e3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee4ba6d8-12db-4f7a-bf9d-56509dda7496">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9970fd08-e822-4f07-a926-24e25f1794a7">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c284df2-ad2f-463a-bbb0-a58e19576e4e">EV (50, NCDR [2.0b], "Pre-Cath Canadian Classification")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7f348587-5c1e-43fe-a21e-fae120961f8d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_879d9014-7638-4d16-b53b-19ecff7b4425">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc50df33-8619-4c3a-9ece-1ad3d802ccbf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d676f987-8bb8-4464-812c-5bba9d27c0c0">D<xref linkend="sect_CID_3719" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6274b4db-2cc2-4951-84d7-6c61ca0d148c">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4573840e-8119-4b20-b6e2-8a0176d6cd02">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05fb964e-14db-4eef-ab0a-5dc366c34f8f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25281884-0bbd-4114-beff-8d20726c786e">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_716e9ba6-a999-487e-a588-d2890e768c3d">EV (51, NCDR [2.0b], "Acute Coronary Syndrome Time Period")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73a444a1-4e29-4c3e-9004-2154de34f38e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7190aad5-319c-4a74-b0e1-00a0c6b72e8c">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8949329-ed1d-4c3d-8864-762e941874c0">IFF Row 9 Value code meaning is &lt;ACS&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ff58900-6f27-45d4-8c22-a8e9a95c780d">D<xref linkend="sect_CID_3735" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_301e2873-5462-481b-b563-f1fbb9e83ea5">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4b5a84d-7794-41be-b724-5b74294c7af0">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0889aedd-c3ca-4d91-b3ef-2195ebeb2ac0">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c4e1fdd-d462-4cc4-968c-20827cbccc9d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3d72558-9eb5-45d2-8358-edff053714b3">D<xref linkend="sect_TID_1025" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5b260a1e-63a9-4c9a-af52-31d7ab519f85">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e6f31727-589c-4a38-9e05-19991c463084">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_14ccc090-2101-4a59-afdc-3779e35f844f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d841c212-0848-4421-8b18-4c499c98556d">$Findings = D<xref linkend="sect_CID_3727" xrefstyle="select: labelnumber quotedtitle nopage"/>
</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2db1f78-8c01-4f1a-bdb0-6b057b195bd8">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dfb0a7ad-b9a9-4bdb-96c4-b4650298bb99">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e65e6881-0af5-4f84-8f6b-3e434c074353">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba0c8de6-996e-4341-aeb3-d28e8d1e02d5">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a53dfc81-411a-4357-9005-a67af3dbd7c5">EV <link xl:href="http://loinc.org/10230-1/" xl:show="new">(10230-1, LN, "LV Ejection Fraction")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3f1ebf09-ae08-4750-b110-9fa6dd41f040">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_75118330-bbaf-45f9-adc1-e532f93550f6">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0fd5f095-2611-4229-8827-f831575af190"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ae1c71a-c02d-407b-9c70-7554e0ffe4a6">UNITS = EV (%, UCUM, "%")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0822d72-99e4-40cb-a4a7-2cdc22d42a6b">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_206371c1-7fd0-4db5-a3df-c5b8156cd71f">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a71003ca-8a77-45cd-b0be-d21aad877b92">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1cc19a8-fc6b-4be9-a06b-9abf4c5c771c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03e158ee-f82c-4424-b959-1a72dad5be19">EV <link xl:href="http://snomed.info/id/370129005" xl:show="new">(370129005, SCT, "Measurement method")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ce595a6b-67c9-46c1-813b-fefce1be0e75">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a150a49e-b050-46a5-89b0-1d07bcdd3342">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79912c98-0d00-464d-8cf5-fd965d27ca4c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02af1b3f-4f4a-4ecf-b0ec-5179d497593e">D<xref linkend="sect_CID_3744" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e19b038e-2f21-4eb1-9a1c-7488f69236e0">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fab0af04-325d-4790-8177-c33375897f97">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ddce9c96-c7f6-4471-bc2d-4aa134aad2d6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c2b60c6-6d98-4f18-aaa0-f3d6b78936b7">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80085163-03cb-4e7f-9c5e-5acaec6d9980">D<xref linkend="sect_TID_1000" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c3313bf1-b64c-4580-81c1-8eb85dc6513f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ed08ff27-af79-47fa-bcce-700f67209dd5">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4659c39e-9fc8-4cb6-8d64-d1131fa05ebe"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f97d3393-35f3-4479-92ad-72b846964ca5"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5aa02b9b-208b-4234-b392-292e75cdd41f">17</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a86ba0e-6371-4974-96a0-0793cde379ac">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f88bbc9-649e-400f-bbb3-704d0136081d">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a3d7b2f-ccab-46c8-8e4b-9251560f9c13">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c46d30d-5ee9-48b7-9b5e-05c0673272c5">EV <link linkend="DCM_121069" xrefstyle="select: nopage">(121069, DCM, "Previous Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e96481f7-06f5-4403-947b-e9da2e21253f">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8a197122-acf9-4748-86e5-de7eee65af24">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4db97384-4561-4877-8ed1-054c0b57d10b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dfc8ce7f-7e75-4cbe-a3e0-72b49356f625">D<xref linkend="sect_CID_3700" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a92cea4-944a-4f0f-adb5-e4bafc26b38d">18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2d1f30df-6eb6-4092-8cdc-4456e0fcd18a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b01056ce-4656-443d-85b4-87917543c477">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa8679f0-e36b-4b1d-8b15-2619c4653fac">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_461d0149-e300-4130-bb9b-8f7890a1739a">EV <link xl:href="http://loinc.org/55108-5/" xl:show="new">(55108-5, LN, "Patient Presentation")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ffecd199-4cb3-4724-86ab-3b0eef12d2d1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_13efb33b-34d2-4859-bf52-cb54397954ca">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24c283b8-26fd-4d21-80d4-150fb392a802"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f142f68-efb6-476d-a3ad-9aaff152b6a6"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3806" status="3" xml:id="sect_TID_3806">
                <title>Cath Procedure</title>
                <para xml:id="para_d2d25de4-1cbf-47e6-9a64-fb44e291f062">This Template describes the patient-related information about this specific clinical encounter (catheterization).</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_be522184-f004-4fc8-9c37-0e7cf6851b86">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_410b2ee5-82ec-41b9-99b7-f929382b0a80">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_23269025-ae7e-41da-aa39-912adaf9ce1e">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3806" rules="all" xml:id="table_TID_3806">
                    <caption>Cath Procedure</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d9557f60-296c-48ce-92a4-5fa238a47cc3"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_740a1679-14cb-4704-b3e1-dcd39eb76530">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1fdaca66-e4ea-4155-b555-112efb9c6d69">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f01e557b-7ec8-4db3-ad91-007fb0b0eede">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_62891878-228b-402d-8b39-f3ac2dec7576">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c643ebd4-be14-484b-a4fe-2786504b99fc">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aa35bcfe-5f21-42b0-b8f8-09d3e2ed6883">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c6eaa0c4-2fe8-4a66-8c9b-532c1de37062">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a5dd7e34-307c-4645-a808-ddb9f81b10cc">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d8f3045-0da4-4d75-8bf2-ece57f9cd9e0">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c6a8602f-2eb1-4060-9e7c-b38a70a38574"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6576dd10-6652-4ef6-95f9-e6f0c03dc778"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6204fc91-c217-4b5a-a3c2-2eda127e0d3b">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80012503-3c35-4299-ac93-aa758b9eae2f">EV <link xl:href="http://loinc.org/55111-9/" xl:show="new">(55111-9, LN, "Current Procedure Descriptions")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e5ff696a-e18d-45d6-a26c-f99768ea5ecc">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6d728ee0-9316-4623-8f73-f775ecd2bcc7">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2fdcade-213f-43f7-8fbf-f0b624ab3f49"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3cc9cee2-1e46-48f7-b2c2-39aacd8321f4"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e13aef75-2f4a-43b2-a7ba-35ea9702e293">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1228a18-7967-47ec-b754-6093fdc82841">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2d6f6c04-7456-405a-b451-4f7ff963de63">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3dd36612-99a3-468a-8a05-c3d29fddf1b3">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_174bdd51-8433-48d1-a2a3-8f80180419e1">EV <link linkend="DCM_122146" xrefstyle="select: nopage">(122146, DCM, "Procedure DateTime")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_71098954-cbd8-407c-8631-5a6d4800d5b7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2b11d27f-7b8c-4059-8746-4f4d5c9c2b87">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff35e212-cd8a-4d5c-ba9d-7c006ac28fe8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc7abb38-edce-4a56-99f2-39143db35930"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bea28a9e-20f5-4a77-a3fd-29315b038561">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9c6eec9-ef86-4ff1-8f48-0f259862c98f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d4d52bad-43a5-402d-8786-463af0835973">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a1cba485-40c4-4a89-9a16-da545d23e899">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_53cddf44-8e49-4ea4-b59c-f4a3d73c6f59">EV (53, NCDR [2.0b], "Procedure Number in this admission")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3396d5ed-6ca5-4a91-8b5b-12d4e3def5e2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4e83258a-9b57-47c4-bf6b-8119523d4429">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_250952b4-0028-43c8-a515-e4c3103a3d10"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d2df675c-3f33-4a7f-b048-ce88b3a95b49">Up to three numeric characters</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84abb55c-6393-4f9f-8664-be52fc462735">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_965c5047-aaee-4d2c-8145-53d9f1b7e1ef">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a60a28c-9204-4709-96b8-583ce43ba30e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_56749efd-f5a8-4fe0-bba0-1368f96f873a">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb5c2de7-636f-431a-93cf-9ffe618e475a">EV <link linkend="DCM_121065" xrefstyle="select: nopage">(121065, DCM, "Procedure Description")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6bcd0acd-9fb0-4244-96c5-ceb2e20a462e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7e3732be-a327-466b-aeeb-1b21dd2d9e6c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4aaad001-a8aa-433a-aba2-17c3e8a83917"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5b8c0a6-42da-43e0-a0ec-79d0411a8f52"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a6f29da-fe15-4a7a-8313-98a5fb730db0">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c6e5c8eb-fa93-49ff-896e-23548413472c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_731cc50a-3e3e-44ab-8654-c365561f0ffa">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7807ff40-e4d6-4149-969b-d84a1f7883b7">COMPOSITE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e94eee83-098e-4767-a005-cd463681e7fb">EV <link linkend="DCM_121120" xrefstyle="select: nopage">(121120, DCM, "Cath Lab Procedure Log")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0b3f771e-d3e4-4340-9fea-05277ce41f2a">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cc9b864c-550a-496d-a7c3-aa6eb14fb7f9">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c453eecc-d446-457d-ac56-aa7e29a30b65"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5b95518-2b93-4a8c-bd0a-7ad6d159040a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_60e80e11-a6f1-4f7a-86fa-7a85db07dab2">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ebcc2f7-a44e-4117-9fef-20cf49e414cc">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_111478b3-c783-428b-8b7d-448ea2116ba9">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_efdaa117-6753-46c2-ad9a-69b1259f18e1">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb514574-73e5-48d3-b63b-d6726fd867c7">EV (55, NCDR [2.0b], "Fluoroscopy Time")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e2d8c14f-a14e-4c81-9379-6cc25e200e88">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2fb01225-42b0-4715-8697-404124989177">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2a5342a-4aec-4b9e-86ac-275e2f3c02e9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31c15f49-c643-4839-ad60-8ee66932b039">UNITS = DT (min, UCUM, "min")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c681fe74-80e3-4a5d-8b8a-ac921d54f3e4">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c20d139-55a7-4d4b-8f83-dec07f640be9">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b291418-7c51-49f1-89e9-754a53e0cb90">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e47ab5f-ec58-479c-88b5-803b45a3a592">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_224cbbe4-ca8c-48cb-878a-899214275fe2">EV <link linkend="DCM_122130" xrefstyle="select: nopage">(122130, DCM, "Dose Area Product")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7e9185f-1132-4742-87fa-755e32341097">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cb720f07-8026-4f52-8df6-fd002eb1456d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af7ca315-03ea-483d-b67f-2f88fd6c50db"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5af4fa5-ca23-47de-a39e-591006dcfa8a">UNITS = DT (mGy.cm2, UCUM, "mGy.cm2")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09c342a2-c648-4f7f-a7f6-5600dfbb3f85">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_45736d85-932e-4bf6-9793-0b3916a5aed9">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fcbae400-6892-40bd-a362-d175c37e3a70">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa186232-7cf7-447f-8b59-0837661dcde2">PNAME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e63d20c3-6f8d-461e-b786-908b3290cfa7">EV (76, NCDR [2.0b], "Catheterization Operator")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e1f342e7-8620-4cbd-9dfc-14a12c3909d6">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_292a398f-157b-4471-8621-2d48ad57a8d3">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c29d59e0-5b86-499a-8329-941f95a6532e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3bdc857-2284-4e2d-a1f7-06d6aaa40d69"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa75b85f-ea60-41e7-8429-9bd44bda13d7">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7a171c2d-de26-4436-bb74-b9d70973b744">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5bf582d7-9380-4924-bf5d-3380cc41654c">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17684cb0-62ae-4d73-96f7-93f21052bc4a">PNAME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5bc5c08-b115-4998-bf0b-82fa52b3a8c0">EV <link linkend="DCM_121088" xrefstyle="select: nopage">(121088, DCM, "Fellow")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_29945c5c-bdce-4533-8907-0969bee4ebce">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9110d46b-3447-461a-b2a8-cb2b01fc502b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2395874d-be86-4267-8749-0bb0e2965b30"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e532b59b-9f0d-4272-bf13-5567ec2d1b3e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4b389f7-77e6-45ce-898b-a3472009b625">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b729a37f-8b6c-4cd0-9a35-c39d247ea7fb">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f755280e-2962-4754-a804-518f55f4e7ff">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2bc64003-88f6-4c91-990e-5f5a78a531f8">PNAME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c0f8bb0-9869-43bc-b836-4cebfbda629c">B<xref linkend="sect_CID_7453" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_20b67b90-5f96-4d42-b31f-e06205236ea4">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_534decb0-5080-4aa4-9a63-5085014c4726">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_544faeb9-f634-4dae-b02d-537eec317323"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ebf9725-ea92-472e-aa87-f824fd8b8bb2"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_057bcf8d-f633-4c07-98c2-20848fb6b2de">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_131a2702-da69-47c7-b69e-d1d4261b5d10">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92ca5857-8cf4-4c76-a1d6-01ceda7e278e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f25940b0-e178-402f-8b6f-2f0639eda43b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0120c82-0d89-4d85-a3ef-d1b2c4bfc171">EV <link linkend="DCM_122129" xrefstyle="select: nopage">(122129, DCM, "PCI during this procedure")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ee239c3-9b34-4d65-b473-0af425ea7cba">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f9b9342a-7496-44de-a2df-af623cc2c59b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46eeca5a-0dad-4722-8260-ae512aa8aa25"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fca26583-0b0f-4eb7-bcd0-58df3fc89e6a">D<xref linkend="sect_CID_230" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_271d0261-5ef3-4274-a51d-d0bdd00abf35">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_41cd9adb-51c3-40a7-bf9a-d3d2b50d786e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd4a96ba-e011-4ac5-bcf6-8da5ed48ec32">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4ca7ffe-d97d-4a94-8b4f-e4291c7c0a06">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac88b554-67d9-4c2d-9b55-2042b605aeb9">EV <link xl:href="http://snomed.info/id/182833002" xl:show="new">(182833002, SCT, "Medication Given")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cb727038-a3fa-4730-a30f-25d0e1b287a5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_009767bf-4e65-46a1-85e2-c4ff74289d7c">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00b8cc2e-8414-453b-a230-a57f5954027f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38b9b964-c21e-4d5e-8901-e9597ec409df"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d44cfea-c448-43c8-b39f-f0515623f5e1">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc5f158c-4435-420b-9d08-cb9989226a41">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eeea80b0-9c38-4a36-95f6-117f84e538ec">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fbf5c1e4-edcc-414f-ac81-47dbc9319981">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2e2afe4-e34d-449b-92bc-1452187ae6ee">EV (57, NCDR [2.0b], "Thrombolytics")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5d210f97-af91-4629-8313-c93683091087">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0892d0ba-f70e-4b53-8b7b-f6a7e97fc7f9">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39bb2859-3a5b-4bc1-b9e8-f26c97668879"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec389f09-1c04-4f20-94c3-9a51ce63bb22">D<xref linkend="sect_CID_3740" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_865f8a23-7069-44ab-8bf7-04567a80f69d">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25e59aaa-fe85-444c-b5c7-22bd2550cf5d">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9b61b97-6381-4535-8ac8-80a938b64c4b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_45c3661d-f4eb-4a3b-8203-d8160cb29a15">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_153e9612-672d-49cc-8ed0-5d405366b1b2">EV (58, NCDR [2.0b], "IIb/IIIa Blockade")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_70f0c248-e3b5-48a0-911d-a483963056b2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69cea4e2-252d-499d-a635-197772dc2ce4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_20cb5450-8a93-4f25-b48e-a3468ed343eb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b39320c5-4572-4c52-8f9f-9ecb88530d09">D<xref linkend="sect_CID_3741" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1de9c631-3f0a-4057-9e22-f266aac84b7c">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b785f22-1c56-4c46-8250-226ac524d4f6">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc4d3412-ef78-4beb-8e21-5e7110397094">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7929d929-3b41-4c59-b43e-ae33985ee445">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0af55ae0-e1d3-49f6-ab80-f73a0f26308f">EV (59, NCDR [2.0b], "Heparin")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc193612-242b-4fd8-b8e9-19de3df71ea9">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0f261a92-4c7a-4d95-82fe-10ee5d1b6a01">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e984f2b-70e6-41ea-a5f3-1f00fd3c9860"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2304583b-cec4-4457-b3bc-7ccbaf76644f">D<xref linkend="sect_CID_3742" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88a315cb-a016-468e-99b1-1dd0f8782fca">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9179a95-663a-413b-8f70-16f90b7e28de">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bca71acf-3be8-4bec-a252-7250c701a35c">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_818b23f0-8fff-46eb-b620-87398b713cec">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e82e20f1-1a88-4a84-ab4b-78f3d1b2cb87">EV (60, NCDR [2.0b], "Aspirin")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eba993cb-bf3c-41ad-98c6-eada5b242ec5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_51e12cb7-bad5-4864-be0c-ad40b50389c6">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_372e9deb-1c15-42b3-82a2-6baafef84efb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22cc2fa5-8478-4722-bc3a-ac16c74d8558">D<xref linkend="sect_CID_3741" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d4c1aa3-1451-4bc2-b240-921f11b22eba">17</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e3def08-9cfa-4455-8abd-94842fcef711">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a555f4a1-e6c9-4c04-bb7a-d85fcfa9bcb0">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_def64788-7f5a-45a2-aedf-dba2401b91ec">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d2e7b45-e9a2-4fb5-9e71-138ad6ae3657">EV (61, NCDR [2.0b], "Clopidogrel/Ticlopidine")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b046465c-e9ae-40b9-af7e-6861beb6da23">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a4aaeba5-b73a-47ce-b3c4-508b8aee0483">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_07c615ee-ad4f-4903-a24f-916e385f729d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3026d0fa-1a18-453c-ac25-6a0a99fecd3b">D<xref linkend="sect_CID_3743" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_33a76ae3-ef00-4008-9214-00a24e418170">18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9dc61524-fb78-43d8-9254-1abda5e20799">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e8f9b9bb-b254-4c19-8305-38a0caecf95c">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6550a0ce-7eb1-4794-b041-de8b05af9a4c">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2635051-2339-483e-9826-af8426cb7fcd">EV <link linkend="DCM_122083" xrefstyle="select: nopage">(122083, DCM, "Drug administered")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fa3a1e46-7501-460b-890d-933e7861a6ce">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b712c5af-f917-42b1-a1fb-93e614430e69">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57da309c-ca67-4266-9d30-22fc8d65f2bc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5cf3fa13-421a-4491-a27c-7ba17736d039"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c4f4c68-a091-4272-9510-f2dd8e516fd3">19</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3991cdbc-c486-4b17-8ae9-3a28a7433d2d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea1ac6db-5612-4535-ac37-af44698a6526">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4ecacd9-947c-4f4c-a51b-ebac27f661f9">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99400547-481f-45c5-8365-7f0b9f456f72">EV <link linkend="DCM_122138" xrefstyle="select: nopage">(122138, DCM, "Circulatory Support")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_597b3a17-4ed2-47e2-9a37-74f470bf94a0">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_91d29484-d6f9-4aa7-a4cb-1053d34a760c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e7222d5-3c5b-4e2f-a40d-563c9fd20384"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10e01483-6665-47e4-8e07-35800379141f">D<xref linkend="sect_CID_3553" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e1d539a-83b3-48ae-962e-ddcf908ac682">20</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c374932-39c6-4565-940d-7b7c6bf36884">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8e2f34c-169a-4855-bfc8-368b02bb4d34">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2db3eec3-6af1-4b42-aca9-5ba2426e5455">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ddb4f01-359f-4775-ab3a-9ba46e13440a">EV (74, NCDR [2.0b], "Percutaneous Entry Site")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d2bdc2e3-4040-49c8-9a8b-8164577c6165">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_109d09fa-81fb-4cbe-aff5-6204aac61a7c">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0d231bb-f8d7-4e50-8ec0-387d829d2ad6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6da21cd3-169f-4828-8702-e290a46c5415">D<xref linkend="sect_CID_3746" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a191c810-5bfe-4db7-8a71-a361e91b7c2d">21</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09aee4cd-9a7f-4d13-ba30-7c4490b267a4">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c14fbc0-c68b-4561-986d-4e4655a2f501">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5fedaa7d-43c4-4212-9add-fbfdf9441497">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3331b577-7bb8-4a93-b83f-489cd79bd491">EV (75, NCDR [2.0b], "Closure Device")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c3317213-4021-4879-a711-a3e95f4be5fe">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_355a62c3-f545-4088-bdf1-16078ae11c1f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_940199bf-debc-4dd7-9ac6-97ab953b1d5d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bbbcb9a1-1410-4369-8ac5-abf856c06a51">D<xref linkend="sect_CID_3747" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_f78d6fd7-3c2d-4bef-b981-6956b4868d4d">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr>
                            <td align="left">
                                <para xml:id="para_bb4e4fc2-7523-4884-b81f-c436154e22c8">Row 2</para>
                            </td>
                            <td align="left">
                                <para xml:id="para_2d7127a2-bd95-4506-a703-eefb2fe9ca9e">The Concept Name was previously defined as (52, NCDR [2.0b], "Procedure DateTime").</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left">
                                <para xml:id="para_6d58c626-2b77-491b-b402-0e3b1ecf37f5">Row 3</para>
                            </td>
                            <td align="left">
                                <para xml:id="para_be71fb88-bf0f-487e-94ec-b13ec3256096">Procedure Number (this admission) is specified as a numeric text string, and shall be treated as the ordinal of this catheterization procedure within the admission (i.e., "1" for the first catheterization, "2" for the second, etc.).</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3807" status="3" xml:id="sect_TID_3807">
                <title>Percutaneous Coronary Intervention Procedure</title>
                <para xml:id="para_5bc92d16-ffbe-46f5-9030-5e3a6a4caf20">This Template describes the various aspects of a coronary intervention.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_9f8a5bfe-538c-4a47-87cf-a348af246bb9">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_60f5253a-9982-4a6e-8629-1fa87862807f">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_31028531-2219-4429-a27a-390393b79c13">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3807" rules="all" xml:id="table_TID_3807">
                    <caption>Percutaneous Coronary Intervention Procedure</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6d240471-453e-4afe-87bc-9e960b7d8657"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73c9e1c6-db35-4c65-83d3-aa15474960eb">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c974353c-fc40-4d69-97fd-c1037ac9586d">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2be31446-ed07-47f1-b65e-cc79592c6d66">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4c8e78da-9121-4366-a5ff-c9a0f16353ba">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_67ae80c4-a90f-402b-ae79-d151382e7ad0">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4df5ae8f-1425-477d-af37-92859dade625">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69be3907-6b2b-4bd2-8a2c-a0b5bd7db500">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fc4461d2-f46b-45ad-b12d-60efe99cc0ce">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd1a6074-5b33-4a8f-b80a-d781718ba654">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3973b059-fd5f-43cd-b2e3-bc468f060225"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a232d2a-2582-470f-bc97-ae4dbfea591e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80ee77e7-60f3-4ed4-99a9-0c46576bcdc8">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc293c44-0701-47d7-bec9-a20e2cd3beaf">EV <link xl:href="http://loinc.org/55111-9/" xl:show="new">(55111-9, LN, "Current Procedure Descriptions")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cdcee4e6-2d73-4b39-b8f2-ca1952e5f2ab">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_80e7a22f-2074-48df-b2cd-1095e8dac494">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e892263-3694-44ac-bc2d-584bb512a40a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1fdaea45-a79c-4355-ab91-3ef27b0ea52e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_298bae4b-33b0-462f-8817-08e5c8a92206">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91a1aad9-bb46-46c4-86f7-622249b7dd50">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f5ec2cf-9b42-41b0-8b75-c11b2f925f6d">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0cd3c9b1-b326-4638-8bc1-1f0b3d65c0dc">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6fc92ffe-7059-429b-ab96-9db5d9ce612f">EV <link linkend="DCM_121058" xrefstyle="select: nopage">(121058, DCM, "Procedure reported")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf2ba3b0-0a33-47b6-9238-f6fdeea4fbb3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b159df5a-489b-4f50-aac9-f7fe68f0c716">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a29c20a8-35c5-466f-a8b1-a0a391a818bb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5d71055-a8d5-4fcd-9abe-b13a79816639">DT <link linkend="DCM_122061" xrefstyle="select: nopage">(122061, DCM, "Percutaneous Coronary Intervention")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b82846c7-0d1b-4720-879b-87b95bd7ab27">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d104f2fe-c30e-463d-9a3f-87272bed978b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_db82dbd7-8a46-4e25-b9ab-9d68d2dc2a80">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_054e8edc-a2ce-4c60-8208-df9a6ce2da92">PNAME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5171112-9255-4a7f-9199-587d279fa27d">EV <link linkend="DCM_121114" xrefstyle="select: nopage">(121114, DCM, "Performing Physician")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3b1ec3cf-866e-493f-8453-170a814a6c09">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a9ba8559-ca14-427c-b032-5e372fe2ef9a">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e415014-f45a-442a-bd91-0598f37bb2b7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec447820-f6c0-4bce-9479-ddd3dddfd147"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_388e7ba0-c38a-42e5-b36f-03758c5c3fe4">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d621e3a-30e3-4e59-82aa-296c0303d480">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38a8f4e2-21de-48cc-b26a-ece25fab2f58">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70e03e5c-0518-4833-b19b-a2e68017d530">PNAME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2d4f64f9-b967-41ea-bdfa-8f9caa636862">EV <link linkend="DCM_121088" xrefstyle="select: nopage">(121088, DCM, "Fellow")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f86bffa-5e58-4cd5-9a69-752aee62379a">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8ce85a18-efd0-4e32-84f3-c02162837e76">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5cf60059-8f33-4b12-853a-11bb87780d0e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81e73b2a-36d4-48b3-a372-4d549e2fd098"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d80c5a89-11d6-400f-a98b-d986d63dd87f">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_816ffaef-631b-4311-9c13-71faba191a2a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a4df671-8266-443d-95be-04d4108edaf0">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8eafe173-ea26-49df-8120-b63570ea844f">PNAME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_abac1c4a-8512-49a1-9b1b-e9c929fd4531">D<xref linkend="sect_CID_7452" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_801a16b1-c9d3-4605-9cd9-b57c9eef01c6">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2adbb99f-58fa-4a6f-8d0b-cafb34f06f03">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c60e524d-c159-46e0-bb54-a39f8a8a0672"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b11e885-2306-4afa-b9ed-348d95db44c2"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_861de5a9-99e5-4d26-81a5-4612a022a364">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82c838df-6d9c-473e-9c08-93c3c3855a0f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8597b7f3-8792-4f3c-8f44-67016bcab585">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ab4b9b8-0e9c-4315-8ac3-0f0c89762b4c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f431a09f-00da-4373-9420-010606be2020">EV <link xl:href="http://snomed.info/id/260870009" xl:show="new">(260870009, SCT, "Procedure Priority")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2114dd38-d1cb-4993-8b30-65e12b5bc1cd">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_087eaeac-6a02-40f2-b1e5-a9fdf099877d">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a364a28f-8750-429a-9ab0-f962e5a01ff5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_01ebefb6-8a1d-4e30-8634-e4c45d725dc1">D<xref linkend="sect_CID_3414" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50e16370-7b73-4bc4-81d1-7f210fc243c3">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af93155f-060b-4794-8c5f-3f80d82f6a99">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_47b96880-bb0e-4dbd-8763-53b9906e68e6">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_07c204ab-72a3-4600-be4a-245dc57427b3">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58abf3c1-1525-4546-91b2-85e4e6c1f9d5">EV <link xl:href="http://loinc.org/18785-6/" xl:show="new">(18785-6, LN, "Indications for Procedure")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_956ddeb5-70ba-4370-832d-505e1f98d28d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9d50f5a3-1545-4035-b9c0-41266bd8c2e3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e38e093-1c61-4e65-9e9f-a5665128a988"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d52eeb0-aa06-4d00-b6b4-533be2a3ea60"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fdd3dd94-a808-4f3e-ae55-f10de4f6e201">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43a4e326-9b2e-445a-ba03-2adeadd08b19">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0414fe38-0236-458b-a997-81ce73ca6b2b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_808e9e33-e5ce-4d01-bdae-614edd7e8878">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63b507ea-12b8-4030-a19a-7eb432f3f7ca">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2f0c171e-3021-4722-8860-2807c9357d92">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b469b5b2-c7e8-4d27-8ffe-45dac63ad6ab">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f5ab5f5-1df5-4494-9a27-e47ccaff9c14"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3826db56-18b1-4861-a639-018f0932279c">D<xref linkend="sect_CID_3726" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d28264e5-63a9-4218-b535-7e36e35b3d97">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b02783cd-97b0-4c99-a87c-53d49e2dd78e">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc355fee-706e-48fa-ae8f-a860dfb35079">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dccabb01-9050-40ed-a6dd-25681c0c6981">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6794b312-987b-41b6-93f5-7e80bc2fb4c1">EV <link linkend="DCM_122172" xrefstyle="select: nopage">(122172, DCM, "Acute MI Present")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_195bf98a-3701-4d32-b098-0bbc90dae878">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fd139396-ad58-48a4-95b6-281e68d3a647">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16747b21-9f6c-4867-8fec-256581e542dd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_56c63a8c-adf7-4edb-a8ee-9fe7caa053f0">D<xref linkend="sect_CID_230" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3eb39a63-f748-4954-9737-9185dd39b4da">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ea26a17-cde9-4f83-ac9f-5aefac599b05">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_007506c6-456e-40a1-bd48-2bd038434fd9">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0104a72-92ca-4326-b33a-026c294c6a70">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f366282d-93b2-43c4-9e57-6abb292b49c6">DT <link linkend="DCM_122170" xrefstyle="select: nopage">(122170, DCM, "Type of Myocardial Infarction")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9c686ab3-c0a3-4f31-85b8-b20607c4274d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d7cce472-2309-429d-bf8b-13f51b8aef23">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09850489-e362-424d-abed-938f638cdec0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8c0c00a-8f43-416f-abcf-b9695e8fe478">D<xref linkend="sect_CID_3723" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_45cdc030-e816-450b-bde8-d90a9106bb9b">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a3e57c9-8076-43ec-8a85-21fdeda0b218">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae277ffb-c8b8-4e3e-9d07-349daba64df1">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ad5e102-8b2d-4385-8ead-cff2a1dbff76">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d75578a-1b70-47eb-beb6-925ae58313bd">EV <link linkend="DCM_122173" xrefstyle="select: nopage">(122173, DCM, "ST Elevation Onset DateTime")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c3f49bc2-b408-45fc-bb60-05f77e4d6564">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b082b234-7cfa-483d-b588-244847273435">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63213702-cf03-4d07-9320-267215e0bb4e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e467af9-538d-4d96-aa65-19d1bad83dd3"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_861f92b3-7406-438d-a445-a79c9077eca8">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d7676ab-2db8-432b-bb18-0161581a0303">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d6180a8-c892-412f-9d41-8c4b8b1a56c1">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5dc04fa-6de3-4bbc-a025-a1f660e42ff0">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec15331b-1dc8-423d-920b-93991ae4ba8a">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_20a4eb14-1a2f-4760-ab93-3c0d0f1b2476">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dd61a7e8-61dc-4b2e-ac16-912a7948fdd0">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af1b2017-73b9-4880-bcac-5aebfcb1f63c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a812307-52d7-4a74-b062-5b1f21f8328c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fbbefd4e-d64b-438e-99ff-0b12ec652e44">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b08b519-27ee-45e8-8689-0c2b9da4b6cf">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d96b4c08-d486-455b-95a2-f107bfe6e3ea">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0172d714-45c5-49aa-8a4e-f5a8cc77c8a5">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_447894ef-2006-42b8-9f80-1d9aea7d67b0">EV <link linkend="DCM_122175" xrefstyle="select: nopage">(122175, DCM, "Number of lesion interventions attempted")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_88e97cd1-886a-4849-90d5-6199bbd81a0b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2548a343-bf31-45f8-b76c-f10d434b2403">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb976114-7bc5-4b94-a81c-713b6687f63f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24b2590a-ed0a-4c4e-847a-86738f22e497">UNITS = EV (1, UCUM, "no units")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca6a81ea-6c83-4450-aadf-63c35b0b5ef5">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8cd2fceb-f006-4a1c-baa7-c01ac3abd06e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06b85244-ee12-4551-8add-d20f700507bf">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b6d4cce-35ed-4413-bb5e-bd993404ef34">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35a236c7-6368-471d-b67b-8706d66fc711">EV <link linkend="DCM_122176" xrefstyle="select: nopage">(122176, DCM, "Number of lesion interventions successful")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_939ab2af-fa1a-41f6-881b-eda57e004a41">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4c1c7135-3ff0-452b-98a9-3a68ddea4792">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e233c786-0d16-4602-92fe-5d8142edae81"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4addfff9-c958-4691-b138-ee12b5037981">UNITS = EV (1, UCUM, "no units")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35deca8b-aa8d-466b-9191-f2ca7ba6cc6c">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e0075fc1-8538-43fd-9842-1f89ee6fd6e2">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11fa786f-c15a-4da0-89b5-9faed9dc71a0">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7de9fcc1-a468-4c01-923c-0b7f9f83c6e9">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae061c9b-3a00-4a08-9c2c-8c759d9fba46">EV <link linkend="DCM_122177" xrefstyle="select: nopage">(122177, DCM, "Procedure Result")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5ace846b-eaaa-443d-9bed-2ea32b325a2d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2bbd3a12-b40a-4812-83b7-79f43b7dcc2c">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85f30856-78a2-4974-bade-25065d5a3675"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d490d74-869b-42c9-8de0-b733800ee26e">D<xref linkend="sect_CID_3749" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_583dd30c-d9a9-41ef-b1f8-1c3944bf82e5">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a49d7ba2-c4be-4fac-9907-6e2dd8f80183">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e21c296-44fe-4a3e-ab85-ff750a964c4a">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e3c34a4-da23-46a8-b35e-1eba05d53b8f">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c2b58099-af00-4fa5-a213-b0b75e6f09db">EV <link linkend="DCM_122177" xrefstyle="select: nopage">(122177, DCM, "Procedure Result")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f5229377-2767-446e-8ff8-b9bca45e6938">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7ad9a003-1352-40d0-9ca2-03a79b0f24fd">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b8b79e7b-e558-4fbd-a446-d6fe5b0e6f08"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a12574a5-93fd-4eee-b3a0-db2e0ff99045"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_47a02c44-36c2-425d-a541-e84744e90857">17</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c640d877-a5f6-4699-bdbf-0dd11272276c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_845af16b-1ce5-4d98-a63e-eb1daa26ed38">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6809aae6-cb03-42b0-9635-7f0b5fdc1315">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8805ea4-d3a1-402f-9658-6481af4bb9d7">D<xref linkend="sect_TID_3808" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_836cd2d9-dba4-4a12-a345-c61ddb13e72c">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f3df02d3-301f-4d8f-8557-d812a5ce3d25">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2541612b-8d7c-4bf3-8ffa-f3a781c5bf1b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1525e608-ed6b-4da4-868c-ea67a842cd2a"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_20762914-a0a2-43fd-a564-99b907e49465">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left">
                                <para xml:id="para_ae083f55-783e-4722-8a9a-e3ede8263548">Rows 8, 12</para>
                            </td>
                            <td align="left">
                                <para xml:id="para_964812bd-03f4-4569-bc8b-28edd303cc96">Allow the recording of findings as either codes or as text; the same finding shall not be recorded as both.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left">
                                <para xml:id="para_3ebe8fb7-6b19-46a1-a4f9-2865e1daf6c4">Rows 15, 16</para>
                            </td>
                            <td align="left">
                                <para xml:id="para_acdeda20-b6c1-44bd-885f-110782786b16">Allow the recording of procedure results as either codes or as text, but not as both.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3808" status="3" xml:id="sect_TID_3808">
                <title>Lesion Intervention Information</title>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_5c7bddb6-f818-4141-94ed-4699033a88a5">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_a22da262-abd2-484c-9d37-dad4d55eb662">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_26825d5c-bafc-4f99-976c-1762049ee95e">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3808" rules="all" xml:id="table_TID_3808">
                    <caption>Lesion Intervention Information</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2fc6e069-12ce-43a4-b327-7e63f169c2a0"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_669425ff-d652-4ad2-9b53-4d2491b63eea">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ec8047b4-5bf4-484f-a3f9-7dc385c363b1">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a5893e6-69f3-4712-b1ea-12c0115c3219">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f813126f-aa2f-409b-b90c-3f65d67f4e35">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0b0dcbe7-b6aa-4fe3-a93a-ae1e3c6f9832">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b9ab4c24-2075-4488-84ec-78a68226d298">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dc57d89a-7747-42ff-bd6d-860b499d98ac">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8d432758-9bc1-49fe-a8aa-8077a8f150a2">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8db21bfb-4c30-4a1b-a3b6-2b256a7ce986">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d95294be-4a79-42eb-ac83-07300625d3f7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d26b861d-1d30-4a1b-af6c-ce90563d4628"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c26e23a-536b-4d02-9c25-6444d718a173">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10635f70-6e11-429c-9e46-20e8e3379694">EV <link linkend="DCM_122178" xrefstyle="select: nopage">(122178, DCM, "Lesion Intervention Information")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f57c4bdb-5422-4f4e-b326-b9cf0c800fa9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_109d1031-090a-477a-8eae-7f476609a6df">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2f14a57-5983-4d05-b066-cc313eecf755"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe7c1324-261c-44d9-a079-829857f83e13"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a84d6006-63d0-456e-902f-cc4b6fb390f0">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74c95617-f2d1-4c46-8c18-d4ce408f28e3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc633f7b-3ee1-49b4-9632-fa3cc349b7c3">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_960f379a-b34a-4f2e-a328-fea4b52829a7">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03dd5b40-077b-423f-967c-2ceab3d07fa8">D<xref linkend="sect_TID_3105" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b1dff7c2-1de5-4f29-8401-41429ef29fa1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e9af6e39-b349-4e14-b034-cb86b176a975">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65885c83-2c50-4b60-9ab4-91c7b66d6406"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36216e2a-d372-4bb3-a463-28df0e759c84"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a74e36ed-4e1e-4a46-9e0b-eb865cdb3840">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8246c08-6f16-474b-ad62-7e2ad06ee996">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c437e861-a576-47af-80e1-f40fbe884013">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c15a90d-59ae-48bb-8e10-7a96fe785b85">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f83a7da7-9d09-4ab6-9d74-29331855bbcf">EV (108, NDR [2.0b], "Previous Dilation")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b914ae2e-dd86-4da9-b08d-e8b793a5ff9b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0c3e2fbf-bc39-4adf-a11f-1ee89c2d1329">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0a6e4e3-da15-4f3f-9b7e-602cbf09a0fc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d7b1c132-d63c-4339-8800-0bcc9dba8530">D<xref linkend="sect_CID_3750" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bde3fe69-eb89-468e-863c-6a1c27c2f652">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e7b4082-bf9e-4a7b-9bab-b7456863776d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d6a7feed-37b5-4c33-bbc1-755713369e3b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b067b14f-6c4e-4113-9680-e1424d14e77b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8eb84e2d-98a2-46db-a508-a29a61e37ae0">EV (103, NDR [2.0b], "Guidewire crossing lesion")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2ee59004-7aee-4751-8c5e-11763d355eec">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0a799bc3-76e2-43f5-beb2-b7d7ba0bfc16">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9956e9b5-de82-4294-8ced-4e98e6f3a5de"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08ddc70c-4df5-44cb-99cb-c45613e9f208">D<xref linkend="sect_CID_3752" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e02c415-dca9-4e6b-9adc-d4f6db1dad80">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c5df5ef-d0a3-4bb1-9aae-cb008970a157">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd37a050-3079-4358-abcf-7cd40c35088e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed5f4989-2a1b-4479-8eba-343a69b6573b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b01c6967-0565-43b8-9cda-9763ca4c33e9">EV <link xl:href="http://snomed.info/id/116682006" xl:show="new">(116682006, SCT, "Uses Equipment")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d5e73cbc-059b-4b18-ba13-659053a57647">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_318fa7ab-511c-48db-8d71-7d37e8c3584f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_805d153b-cd43-4588-95dc-e52694133ca6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff2a4c63-5a70-4edf-9a37-77de85b6b8e5">D<xref linkend="sect_CID_3411" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7296e8e0-dcf0-4021-aab8-c29f371d63a3">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be2913ab-f1c3-46f3-8d32-7dded6db1883">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f03c0fb7-429f-4661-b198-abb6106bac3d">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5816b4f-6f83-4e0c-8ffa-3de8adfa6f4d">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4835758f-55d9-46bd-9079-fe7746261959">EV <link linkend="DCM_122111" xrefstyle="select: nopage">(122111, DCM, "Primary Intervention Device")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eb7a4baf-2712-43ce-a0f5-c178e72efd48">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_115e38ee-f0dd-40da-8e21-27eb8dbb281d">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e8df0cb2-fbdd-46a1-af58-6b90b49291cd">IF Device is Primary for this Lesion</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_632eef1c-94b3-42d0-971d-188705c549ba">D<xref linkend="sect_CID_230" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5cd347ac-93f8-4b8f-a56a-6d292dc4afb6">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e938f7e-f3dd-4e74-904d-35a4f776bf28">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a0bab8f-e294-4da4-9c30-670b1c87319f">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1be2920d-b1d4-4002-948b-9b221f757906">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa7a1857-34c3-4ebb-a8c7-eb607dd3f5ec">EV <link linkend="DCM_121145" xrefstyle="select: nopage">(121145, DCM, "Description of Material")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e297cfe3-a062-41f9-9a86-5365f33449c6">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e68bd705-4754-45c0-ab77-0d799b310cab">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_582d031b-cef2-4416-a5e4-6a186ecec561"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7cc1f05e-1606-4292-a385-e8e7ec6ee4c9"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_654d14b3-2f37-4940-8dca-441a9544d6ee">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b20bd9c8-31e2-42d8-9944-b7118d83390b">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd4ed8ee-c18b-4afa-bef8-2459f14685f4">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a614342c-2cb8-45dd-8f85-bba554672745">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91eacad0-33c2-4eb8-b9ce-9132a0ebea12">D<xref linkend="sect_CID_3423" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d269f1fd-bdcb-465f-ae4d-bfdc921c93dd">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e526908b-bcb8-4d83-a29f-047cfd6970d3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c664b64-12b2-4065-a513-cc772529542f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36404941-5524-4998-9fae-15e13edb85c8"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d431adff-4f26-417c-a726-521670e9a2c9">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52d82ef5-5cad-4515-a8aa-c196ac8f675e">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de61d129-fca7-4d3d-bdec-88ccbe502031">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5590e68a-ccfa-4b85-a8b2-aa1651e37471">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cff3882f-39d7-437f-86a2-3e4eecf9c2a6">D<xref linkend="sect_CID_3425" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_068c5cfa-47d0-4b12-baa9-1d7b10c332bb">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9278dbb1-a399-46c1-a6ab-49bc922200bb">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2c33a2a-ef5a-4e89-80eb-94dbbac0c24b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a85f98d4-646b-4f0e-b7c7-c8a348922e5d"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e3c5221-7fed-4227-915d-54e7067d0999">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d16bb8cd-51e8-49b8-b8d1-09c84d085c56">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_49746594-9dd7-44e1-9cf1-0ee9a5ba9e6e">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a85d1acd-5398-4932-b0ba-09caf0a10221">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e700312-4efa-4916-bd00-bbb0995deaff">EV <link linkend="DCM_122105" xrefstyle="select: nopage">(122105, DCM, "DateTime of Intervention")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf1ec76e-ca4b-4366-ac9b-fcacfa35f0c9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_efe6be18-fead-497b-8ca7-e5be768edca7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ebfdeef9-dbbd-43f6-b34c-1e40f98488e6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8dfda1ab-299e-4a55-9541-720fe5e0e136"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ee61bfc-a49e-43f5-9713-1fea93a4f793">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a419fdb-a210-4f23-a28e-e4c131050146">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e4d153b-460f-4b7b-a224-7c2a8907e543">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3404de16-3633-4090-b5a3-a7077657f408">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c168ecd-a2d8-4bb0-a4de-a5823e98c244">EV <link linkend="DCM_122106" xrefstyle="select: nopage">(122106, DCM, "Duration of Intervention")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e0d51150-d220-4e0a-ad62-1b9d0f883ddc">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_79cac046-c455-4c59-bc32-3786d206a55b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ac8489a-b8e0-43c0-9302-a5e3a12b1490"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d97b3880-c970-4a96-b9e5-794dde912d94">UNITS = EV (s, UCUM, "s")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b2b4d56-968b-47fa-a6a9-7c024dace90f">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5fbc616-a5cf-438e-b769-ba1d109a8075">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3cf37b18-ac8c-45c0-94f0-b7b737b92ffb">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72df552e-8a08-4e22-9696-f2993e330ae8">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39348ad9-c5be-4ace-9ae5-e1b040bf97ab">EV <link xl:href="http://snomed.info/id/408715008" xl:show="new">(408715008, SCT, "Lumen Diameter Stenosis")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a0ee22ad-1f02-4d8d-b3b5-ad39b47d3191">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_82ddf222-cccc-4e29-91ed-437821b5fa05">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf2d76f0-407b-45fc-bba2-75d9cece1009"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3b073d0-d719-4e9f-8eff-8a494382245d">UNITS = EV (%, UCUM, "%")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69c21168-2424-41de-8bc2-ac8995e77fc6">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6624d93-66c1-4e6f-999c-52bfd8d9bbfd">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10d8726b-3856-4bd1-bc04-71fb4cd921be">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_527788c2-e62e-40b9-85cb-947ac56f5dbb">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98c389a1-70a2-4e82-8e0e-3c80b29d7299">EV <link xl:href="http://snomed.info/id/129085009" xl:show="new">(129085009, SCT, "Catheterization Procedure Phase")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c7c34e89-566b-48af-813b-96f5498dca39">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3daf5f2b-e815-486a-95b1-a2aea4e4a3d2">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_225402c0-4689-4742-8c57-565459c7ea11"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_19f5dedd-c015-4ed1-8833-fbbf65e52a83">EV <link xl:href="http://snomed.info/id/128960007" xl:show="new">(128960007, SCT, "Post-intervention Phase")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_78740219-2a9a-47cb-8e82-e7c93b67da68">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8cac61e6-721e-4a8c-9987-595f7da86aec">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2093e635-07df-4055-9300-4ff42a9a4c7b">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aff26de2-a93f-44f6-8299-a7ba110e6886">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff959574-7f63-41cd-8397-02d61a6d0d9f">EV <link linkend="DCM_121401" xrefstyle="select: nopage">(121401, DCM, "Derivation")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_975dc5fb-2bbb-4c88-9c2c-3b100e2cbcc8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e50a0da4-1d3d-481e-98db-ee1a8cd838c6">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad83ab96-a682-4149-b8a8-e333acd30a39"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3aab754-d957-4c04-bfd3-36d49905fa49">D<xref linkend="sect_CID_3745" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ed7dd12-d532-46a0-b0fc-259a182b9a57">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ecc16cea-75f2-4e7e-a0fc-d0a0496dc64a">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb199371-e822-4105-8b0c-dc812936a642"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be426e30-e35a-4319-82eb-5d235b0e2a71">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8cef525d-c17c-43d2-9c47-260693c00c20">D<xref linkend="sect_TID_1000" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d1afdb2a-a8c8-43f2-bde9-d293eede24e0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e9ddc7a3-a1e8-4771-b806-2fd8954c68fd">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8bfe1a04-2906-4fcf-a651-4529a1456c13"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3fa911b6-d2bd-4bd9-bbbf-b6cc83eec639"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4269138-be96-4355-bf56-65c39a621dfb">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_edd0fbfb-c76a-44eb-b4ae-4b19ce53d61c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30dd6fb9-5aac-4a2a-9627-1acb93cfabfc">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee3ae0a6-4574-47de-9ab6-c858730f971d">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff1c21a1-ab89-45cf-8804-bf7fc894d345">EV <link linkend="DCM_122110" xrefstyle="select: nopage">(122110, DCM, "Post- Intervention TIMI Flow")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ced6bed9-4b1f-4d64-aa73-42447ed6705d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8114aa7c-9072-4b28-913c-231046a73920">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_627a320b-3e6e-4d74-bce9-3fad0e6e0f63"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54026c44-85a8-4a96-bc1c-fa24b193944d">D<xref linkend="sect_CID_3713" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9593ebcb-4edb-4cca-be78-0999fbe1d6a5">17</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dea61878-b06d-4d3b-9e41-65d356e0e68a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_449705a3-0c92-4fe5-8ec9-884ee0b15efd">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab5795a9-a177-4b36-ac89-ca9ed8c34ec2">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a035888-cc7a-433b-887d-4057f7319554">EV (115, NCDR [2.0b], "Dissection in segment observed")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e277b9ac-ee8a-4ba8-b66a-bd53ce8ab06e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_82ec7ca8-4190-48ad-894d-962536bc0d37">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37714d6b-2c40-48f7-9b58-93beb4d5f308"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d14c6e91-0635-42ab-94a0-aca7c2a483f4">D<xref linkend="sect_CID_230" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb73d91b-5d8a-4f1a-820c-2a37167d7180">18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b7245f1-9d4c-4eb6-b03a-4d9ad1b4e204">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5837aac-9dca-441e-944e-45d4be17e066">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6be3a5b3-033f-4279-b946-64da18b49943">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6866896-4165-475c-b8ff-7e3a290bbcc5">EV (116, NCDR [2.0b], "Acute closure observed")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6def90fa-2a46-4ed7-9260-5938cd968933">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1484e730-dab7-4cde-94e2-05a5c2f7c875">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_89857515-03b5-43de-9665-ba502e4d1dde"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3aa092ca-1f95-48aa-9fb5-483e764df6fd">D<xref linkend="sect_CID_230" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_adf4a1b6-1635-4759-8a09-ee4efb55bc5e">19</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c87931f8-1720-4b96-89ec-95baadd70651">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a56375bd-4936-42de-99b8-5c51c0b122e6">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_457ca6b1-1858-489d-961f-5fc1408c9520">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8807441b-fbbd-4ebf-9be7-a810535de01d">EV (117, NCDR [2.0b], "Acute closure re-opened")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a8d35366-df4c-427e-80c2-58968378912f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_df9a6e86-2215-405d-9491-362ca922d13e">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f19a187-dbf1-4967-918f-0cca30c3b952">IFF Row 18 value is &lt;yes&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ffec8e65-523d-4acf-ac7e-85ee9d3db6cd">D<xref linkend="sect_CID_230" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a8a7b0a-f4b8-4249-86c3-dfbc37a96b2c">20</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_68b8a43c-07a9-425f-a66e-924d84d13075">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51285839-9b74-42a9-be19-fc54683a6beb">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0393e7f9-3df1-4bbe-924b-37c539bcb99a">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84297b2d-f2cd-46f4-8a1b-30bb076c0713">EV (118, NCDR [2.0b], "Perforation occurred")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cb28c85e-a173-4d65-b36f-c58a2b939c6c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aa177fdd-64c2-4b3b-a68c-411d47359b17">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_381fecf7-9dc1-4653-863e-973b782f57be"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5be775f-05dc-4361-8dd5-d81df115f891">D<xref linkend="sect_CID_230" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3068a682-9426-433f-abd4-d3fd1e840ab7">21</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f6f2026-06b8-4352-a422-9162baefd4d3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d587e977-87bd-456c-b7a9-780b9a0cd11b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4488daf1-60b2-46b3-bcdf-6feef02bf130">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6443056b-83fd-4300-b401-f26920a4c982">DT <link linkend="DCM_121080" xrefstyle="select: nopage">(121080, DCM, "Best illustration of finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_05be7e69-73b4-426a-8519-1ada57965d07">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_68b5a65d-5744-41c4-8c2c-e3988d6abee6">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7771d9d-e5d0-4436-b708-407d61587b4e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d981ce7b-3648-4fe0-a64f-1cf9b904604a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6fe87319-aa56-4d47-98d8-3dab90493606">22</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_912aab8b-ed3d-471e-8cde-7bef803d0f45">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51505a5b-4350-40e8-a079-f352d8e7d733">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7db4ac12-bead-4d8e-8a4b-d1761e2b2bbd">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_071fc5da-f147-45bc-b5bb-f2fa7ee15ab8">DT <link linkend="DCM_122177" xrefstyle="select: nopage">(122177, DCM, "Procedure Result")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a99f95b0-087d-4570-8d17-aa92dfb7764a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2f3ada9d-b5a7-425f-ad5c-c8426aede26d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_346e47bf-0d78-400c-b0fd-a6a82f09a4b8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_294d344f-fd70-4d41-8449-311c48b5fa7d"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3809" status="3" xml:id="sect_TID_3809">
                <title>Other Interventional Procedures</title>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4ca77605-ad2e-4b95-8b23-a86b79eb78fb">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_3f04f700-dd32-49a6-8522-1e34a905a265">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_c1fa0126-59db-4be7-8bc3-6029e7c4edf7">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3809" rules="all" xml:id="table_TID_3809">
                    <caption>Other Interventional Procedures</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3c3a2ba7-f410-4a1c-90c4-ea3921449764"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eae559d3-63cf-4f49-bbd3-e2183fcd8708">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_940052ff-1c3a-4dd9-b02e-a114f1586aa9">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b6f38d41-aae6-4001-b485-68f3b741f39c">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_51e2fd04-3bc6-47fb-946d-891256f0c770">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ee0ae5e0-7dbd-4082-9013-591c688ca598">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_af604e65-9e06-4881-9a81-3ebdecc38f7f">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_42fa90b0-1e43-4c92-a338-c6596a0c6a35">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6bdb3721-279e-4e74-bae5-bcf00a9a90bf">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e147f84-79ae-47ad-87b8-0fbe311f843b">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae762782-a5a5-4c86-a839-9b3c681a1522"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5dde892-3a88-4693-a5f2-90f2416ce0e1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_055bb68f-e40a-4259-956b-6c657efd23b6">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4365cbf-c20c-43a4-bf5b-5efdf138411c">EV <link xl:href="http://loinc.org/55111-9/" xl:show="new">(55111-9, LN, "Current Procedure Descriptions")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a32eeb50-d031-477c-bd87-88604c1573d2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fccb2bd6-5084-4029-81bf-1333c0586220">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b135c83-ffd1-4aba-804b-e67cb825c09c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d294198b-0690-4ac3-8684-6aae3ff4f631"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30b4edf5-2432-48bc-a4af-3fd403508170">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16f99418-218b-49e1-9c23-ad63de56c7d5">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb976d6e-3572-4b1e-8dfa-3ea21bc29db3">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_715c62b7-ab7f-4034-97f8-21040878ed8b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5a33dc9-cd46-4d1d-8bfa-39799d790e11">EV <link linkend="DCM_121058" xrefstyle="select: nopage">(121058, DCM, "Procedure reported")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7b0cc586-5889-494b-a789-2c4795ebaa89">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c16dc8af-01ce-4b57-b1b3-269484c8b04b">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1694e3c-a23c-433d-997f-c6acce33e632"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4095342-de0a-4f8d-ac2f-a823e7720c49">B<xref linkend="sect_CID_3406" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f84e22a8-aae5-4f53-b231-aa4018237340">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a28da9ef-f48d-4a73-a37a-5e67be5a2794">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54ae134e-2120-482a-96ce-4d79ad8cf58b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f29aebe-3190-4101-9c1b-77fbe5dd5021">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b8239795-a853-4b55-8b34-11508574e4e5">EV <link linkend="DCM_121065" xrefstyle="select: nopage">(121065, DCM, "Procedure Description")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e31d8940-5260-4cfe-a170-ed492bcde85d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e913371b-48f7-4bee-af60-e9924846299a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_db17fabb-7b34-4d76-bad4-7efe00fe7ba7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_33ee3801-ea4a-4e90-bf49-529c7be3bbc4"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0cfd693a-0cbf-4b61-9cf4-05a94d5eec44">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd3792e3-4a68-40e8-9263-ced5f2a451d0">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7de3e421-c3dd-40c6-bb3c-9f8f4f461a94">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54f3b272-04de-4ccf-a877-a19000fd0ed4">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c04d1674-f4a6-4e34-823c-dc87d6de171e">DT <link linkend="DCM_121065" xrefstyle="select: nopage">(121065, DCM, "Procedure Description")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1a549a51-e7de-4420-931e-4023a5d5788a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c4ffa452-805c-40b9-a8b0-b913589246d1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e189713-186d-4136-a6f9-6cf154dae0c2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6827b37-a48e-4a9d-89de-9d6d4ced3131"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c427191e-dbc0-4bd1-bf36-ae3297d5790f">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1fc8e64-7869-4f96-9850-971911a6e348">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8637bf63-32f3-452b-b5ba-9c308dfd4c0b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6a272ea-74e3-45db-afea-f80ca5eb5648">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b158f84-9694-4f16-9562-c6b75d4f5f2a">DT <link linkend="DCM_122177" xrefstyle="select: nopage">(122177, DCM, "Procedure Result")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_84ea0e15-dfff-45fa-be8c-18b89a7dc1f0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_55317c64-03ea-46e0-9aad-8afa7fe21708">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab3c4d11-7256-44d9-a049-08343c338aa3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_deadf258-9a28-468f-9780-574618f900e7"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_813cd929-9afc-4225-95a7-ab399d5dcf80">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left">
                                <para xml:id="para_bfc933bb-0aa0-4187-8ef4-6a43b09432b5">Rows 3, 4</para>
                            </td>
                            <td align="left">
                                <para xml:id="para_80712157-2019-4a0b-89ad-f3b04ee57cd8">Allow the recording of procedure description as either code or as text; the same description shall not be recorded as both.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3810" status="3" xml:id="sect_TID_3810">
                <title>Cardiac Catheterization Findings</title>
                <para xml:id="para_521d3d6a-4e42-4e1d-a818-bccc77fc19a0">The Cardiac Catheterization Findings Template provides the structure for the diagnostic findings of the cath procedure, organized into sub-sections based on type of sub-procedure. It also provides for top-level summary findings and diagnoses.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ddd51651-1d3e-4d76-8a98-ca6f7d43008b">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_4eddf497-5c27-456c-85be-bf3a9d20324d">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_1ccaeeb5-92ea-4b42-bafd-7217f3957eee">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3810" rules="all" xml:id="table_TID_3810">
                    <caption>Cardiac Catheterization Findings</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4ac5e43f-687b-4bed-af28-65d0d5e85645"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ca04d99d-62ab-4a13-b03b-d42ecc8545e0">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9701e4be-c37d-449e-b833-efde6f156760">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f984713-2965-4384-a5ce-bd2c727dcf6c">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_496c202c-5cc2-4685-8c74-93675ffc7cc2">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8cd9bc54-c858-4b11-a5ca-bfca1faaece3">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0bb2b49f-4132-46ba-80ab-6854bd82bd8d">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c3fc8809-9367-48f0-b56f-f4889ee551da">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_467f4061-05c8-4152-a898-a0b349d64e34">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ee6a0a7-bba5-4edd-a0e0-89b9147ef989">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_052b63a9-29bc-4189-ba1d-064cfb2b658d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24cd1ef1-7138-44a1-8c14-0d06f5e7423c">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa920114-9a9d-4c8c-a7df-df6258db9d25">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3fc3bb6-0870-439f-97b4-3ecb40bdde74">EV <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ed82577-01b7-43c0-862e-dd6d7b956e82">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cb45154e-0aa5-4c86-8be2-4a11df2497b2">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_339cb6e6-8327-4ccb-83b2-66a653b72ad8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f5596ec-90ab-4a5c-b507-1997290135a7"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_699ce673-126a-42a7-8f03-6c0561ce7bd4">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7506adc6-9597-4b20-9d07-86ada9e3f4d2">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0297ca11-2241-4afe-8158-418cc11d2c86">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_094fa7c2-d01a-446f-94cd-5604b4a8a0d5">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16d1db60-99e2-4842-b22c-74623aada095">D<xref linkend="sect_TID_3812" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2f665a29-4aad-4267-8adf-b07572209da4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_99d55571-fb49-4f2e-9583-57ed827f5e35">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd290640-0625-407b-a188-4e98dea18778"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c596914-ead8-4f68-a3ef-f088ea39b617"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0adfdfa-da82-45eb-81f5-ca4c6306f14f">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5f4d8c1-88b1-48e9-af56-c6ed05981fb8">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f60f062e-c374-4ca6-85b8-2a11a3e506f9">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b270f2d8-9235-4d86-878a-60770cdb2773">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51893c36-bad7-4a5a-8036-917f8cff1557">D<xref linkend="sect_TID_3817" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f4b3a1a0-2686-440b-980a-ace3e5bef179">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_163c8106-a789-4d1c-9a6d-87b9db97221f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_34136992-2dc1-45fd-99be-25909c637be2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_acd875ae-1fb4-471f-8358-1d760ad39789"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4040cf80-bccf-49bc-a5da-f1877d35c177">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_776d8e7d-6af8-4301-b0f3-b7c44bdd6706">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc789ea7-9813-4ed2-84c9-a6c9a435773e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27035f4f-4ba5-4dfb-8643-74ed02654b4e">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c24a20b9-b61e-4825-a535-57ea9c7fb31f">D<xref linkend="sect_TID_3814" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_88bb7684-2f64-4b00-8630-e203506c007f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c87f5ce7-93d1-43ab-ae94-ddabdaf7cc36">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cad67dc3-e8f5-4977-82e1-f244266e5f0d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16309cd1-790b-47e3-a073-0280a0a9caba"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1cbd7a14-178e-4f07-9dea-82f16b366729">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb769a53-1afc-460a-9e6e-3933c832c3da">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_454ad80a-8e22-4911-929e-db1de846e96d">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9eb7121e-e00f-4068-a263-064353d715e1">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02174395-dc04-4be8-a1a2-a3602e277f51">D<xref linkend="sect_TID_3815" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_92ef41df-0fc8-46b9-a9f7-53bdad0179d7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_776403de-05ae-4ba8-928c-d9903b6d12b6">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f79b8093-0fb3-4922-bba2-2cc1f4cec8c5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a9303bd-3990-4f67-ac7c-9d2574a6b45e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb192084-27ff-44ce-a85d-1a56e835ddf5">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc30257d-6df1-4b2d-a89d-da478ea28236">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c75f801-761b-4f24-a8a4-e43571cb8b32">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_721ff4c1-39d2-4f5f-ab34-7628c74a1666">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bac202a1-4f76-46f2-a8f6-f4565aa8eb16">D<xref linkend="sect_TID_3818" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_30bd8093-7df9-42d7-ba77-85bd60019ef6">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e491501b-9430-4999-8559-569d8ceb7281">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fadbbcc7-3239-4b83-ade4-ed2cd77c6c84"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac961f58-2dc9-42ce-b83e-54ade17368f0"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af973ce4-3f2a-4173-8fdd-f91996b8845b">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a7b74a1-9f7c-4d4b-8d95-fe7b4fd9af66">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0cd27da3-2652-4777-8a82-ba6fe0229b8c">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8d65767-4891-402a-a34c-5d808e1c9da6">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a7239a3-431e-4f66-ae5d-12410ff3cf88">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c7f76f75-adea-471e-a35b-b0d678d1a107">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_029448b5-28bd-4a1e-be12-c6c420805556">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_abd25253-d638-4ad5-889a-c697f1c2452d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_309b4f37-eb44-4727-8c17-91519e0dda5f">D<xref linkend="sect_CID_3700" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a1a640ea-c9e2-4807-bed2-c60be85be545">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ff6ee83-288c-4ffa-9365-d7074e487c3f">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_795cf950-bf97-4168-8cd7-37980a3fdec7">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e1d721ba-4393-4617-95e0-900c7f6f4fdb">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b70cb697-99d6-4e2a-846f-de75767c6fe9">EV <link xl:href="http://snomed.info/id/246112005" xl:show="new">(246112005, SCT, "Severity")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aeb9aa35-9e93-492a-862e-ead10774bc99">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8cfbac6d-2a67-4413-8a9f-8d5247f4db25">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b182890-7562-4d8c-aa24-cbd347f7445d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_139d6a7d-7655-45fd-ac7d-2e53e223a546">D<xref linkend="sect_CID_3716" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e391543e-734f-44c7-9ce2-6c0321df67b6">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7c1d8dc-51ab-4ec0-b7df-10ab481ff50f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_db0f7c91-96eb-4404-8e32-8c65b09bddfe">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_531ea7bb-f36f-4943-ae20-0d3494d95339">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fdc229d1-a57a-4648-a920-d3ece365c881">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7b236509-2c51-4e38-86b7-29be99f3d7c0">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_666c336a-1cb7-46b2-b1f3-48a0d4c50a05">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1489e4f-368d-4b5d-b173-c0ee8edf8a78"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7de6f021-99ad-408f-9ae2-f76bf1d528c8"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_4c379245-2dc4-4eaa-95da-6c2097677598">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left">
                                <para xml:id="para_e6f65d44-5a03-496a-bc5c-60f7e746926d">Rows 7, 9</para>
                            </td>
                            <td align="left">
                                <para xml:id="para_f45d118c-2de8-4d8a-b4d4-f63c28dadb31">Allow the recording of findings as either codes or as text; the same finding shall not be recorded as both.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3812" status="3" xml:id="sect_TID_3812">
                <title>Hemodynamic Findings</title>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_6cc91b2d-4094-48dc-9cf5-dd7107af4011">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_a86f2161-bf8f-4be6-afb0-f70cf245393d">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_3236ee5a-fb7e-4350-920a-99e691ee009a">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3812" rules="all" xml:id="table_TID_3812">
                    <caption>Hemodynamic Findings</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fd998133-90ea-4385-94c9-6fb2bef99904"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a1b56c24-bb8e-435c-a780-ba1d51085ae2">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_25474e0a-e5e6-419f-ae52-b1068d257926">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8beb98fc-41a6-4e2c-8e91-7080a043523c">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cc605c03-e9d4-4fbc-ae46-b6d36c75b87e">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f278aa36-e88e-405b-9c1e-219df47de36b">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_186d5ecd-b3c7-4819-8e65-77fdf0023f6f">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cc701248-c2e3-461e-8e71-199f888cc7bb">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_807bd5f6-be03-4c9e-99dc-91d597b4f6d4">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_084236d0-ce1c-4b1e-9724-712482229aa8">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6325936-ce9c-48ba-9f70-dccf9ec57fe1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd8a347d-ed1f-4197-baa3-7fa890769daa">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1f5c15e-e7ac-4777-ac1e-ee9d351fc2c5">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2094361-4922-49ed-9917-977a89f6c1b7">EV <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2cc3370b-febb-4c79-ad66-e118b7d48554">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3c4d597f-9bd1-4056-aab0-26964fde6829">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_616ab3ac-deae-4f36-89ac-726be31899b4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_12c57a05-9a08-405b-a21f-47fc3834990d"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a582a4ca-3ea2-42fb-a93a-8557deca55e1">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_01d38ae0-94a5-435f-ad9e-865d747410e2">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8d66c53-7cdb-4370-8bcc-9b9181a02e12">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ded9b05c-3143-4009-959b-1e55aa125589">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_436c1d41-31d7-443e-b3f5-90c0c3abb622">EV <link linkend="DCM_121058" xrefstyle="select: nopage">(121058, DCM, "Procedure reported")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7c63e6aa-5be6-4d36-8715-89d31cc652dc">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3137979f-291f-4c74-b9d7-cd0eece53a5e">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f5b1072-1528-485e-bf2e-1610eca1d388"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ddcb023e-b47f-4400-a496-7bdc2fa4c126">DT <link xl:href="http://snomed.info/id/44324008" xl:show="new">(44324008, SCT, "Hemodynamic measurements")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b9d8baed-902f-4296-9832-5d5e21aecb33">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6992a83b-ecc7-46d5-99a4-7c134b500d3a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62aa131f-1bde-459f-9116-db4f78b0052e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_795a919c-cf62-4480-ab58-85e8c0a8fe3b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6bc6b0d5-398a-419c-9742-a8db3a386abe">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d78ad720-c76e-4391-8d11-4d6e4a737e4b">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb1a8d7d-ad06-4c5f-9d13-22f195a144f1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e224a95-4554-468b-a0b3-7be2ed42c49f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc12fe79-421d-4a0e-9543-d39bfadad516">D<xref linkend="sect_CID_3640" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d264b94-b3f0-4c10-9bf9-21cd9ac6f552">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f52d4d44-7846-43e3-a373-67592a358d93">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4581018-3273-4fab-bcde-588bf11a0be4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b28fd0c1-2bd3-49ff-9cf5-140374862685">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_34047516-ff48-4646-bdba-3c5695c8d563">D<xref linkend="sect_TID_1350" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ba627f69-1da3-438a-8160-72bc98299bed">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d3eaae38-df54-4993-80e3-77ed550731c1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_33047be3-afab-42b8-aef8-51c86d94eb7e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eca93d81-5748-42d3-99d5-4f95371ecf0e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd4815fe-a120-4c85-a740-2e74ed003b4d">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36442d02-2256-4e09-adab-a787ada9bf22">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d72b8dbf-cdfc-49da-95ed-b75abbdbfb13">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b1c536a-ec76-4fee-bc11-f13a3de3afc9">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5da7e6e-011a-4006-80a4-76c71f1f4222">EV <link xl:href="http://snomed.info/id/246112005" xl:show="new">(246112005, SCT, "Severity")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_355ac3b1-9d0a-4436-8560-3b60f40ff7d2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_244893e9-a577-4fe6-bc76-13f301312e38">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e0aec28-69b4-4a03-9e2d-6342755c8022"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1aac267-5766-4ffc-8b79-a02d360d67f1">D<xref linkend="sect_CID_3716" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_856d680c-403d-40d1-acba-3cac90d6cacc">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e9d59fb-f5a3-407a-a30a-f8b35d98dc3e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79a8d4bd-90f7-44e4-a9db-b84ce32a7f97">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d4843222-b02a-4dfb-aba8-58cd5a24435f">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2744c45-acbe-42e0-8244-dada258b4ab2">D<xref linkend="sect_CID_3641" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf93a7c6-117b-4228-a839-058e9ef63085">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_300877d1-6468-44db-bb83-3013a5d1f1d6">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cb5c2e38-e74e-467e-b761-75b43e39e3e0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1711b7d-48eb-4b0e-8693-264c90ec2876">D<xref linkend="sect_CID_3642" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f7d1cd6f-3502-47e6-8d95-95ea73a8b306">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3488c3f-0134-4d3a-b66f-874776e8fcd1">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_981f3afe-d151-400e-ad33-0b5ed2b9fade">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c47f48a-5f83-41c1-8a53-f0ac313be34a">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c28b06b-4746-469e-b415-76cc443224ff">EV <link xl:href="http://snomed.info/id/260905004" xl:show="new">(260905004, SCT, "Condition")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_67c2ee02-feca-40ce-abb3-ed3ca8c5192f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_506e4c56-dfd7-45bc-8ace-261a9bfc0430">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39bc9c5f-93d0-47ca-855f-1dd8010a02da"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92f06aa9-77c1-46ae-a107-211289b058f6">EV <link xl:href="http://snomed.info/id/414576002" xl:show="new">(414576002, SCT, "Large v-wave")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26144107-9d26-411c-bd5b-d83ec6a5c395">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70d0ee22-9ea9-44ac-9854-b6cc1d11e9d0">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2be5ef54-6f10-4acf-91b0-b5f2ae4fbe6e">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd32a8ef-710a-4557-ad7a-1222d1d04377">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48871a6c-73e6-42f6-8a97-8d5d9c54414b">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a162f94a-17b8-4e80-a92d-3ffbe013f4e5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eef8b4e4-2ae5-4fda-b8c6-02bc52d10a2c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3c92864-49b1-4031-b6a9-da79d0d830ca"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ba2b42c-79d3-46e2-b772-ef291b284b64">EV <link xl:href="http://snomed.info/id/413985002" xl:show="new">(413985002, SCT, "Diastolic pressure equalization")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6f63a06-616b-4245-98c3-e6bfc66a88b0">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed94b4ee-2138-43f5-9329-89f79d1887b9">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_790e8b41-2b26-4655-a939-960059f0f9a4">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ab6a36c6-d196-4a0e-892f-0b5f914ab79a">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04a253aa-0049-485a-8f6f-80905c562447">D<xref linkend="sect_TID_3819" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_86f16454-f327-4e3d-9513-98ab70368e86">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2a03db1e-1dcd-466e-b09a-d4e3058685c9">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9b1796b-91c0-4378-aa5b-5d483b751e07"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d462484-8239-463a-b11e-7daa9b94660f">$Report = DT <link linkend="DCM_122120" xrefstyle="select: nopage">(122120, DCM, "Hemodynamics Report")</link>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_2df699cd-38f6-4f34-9791-9d79edd78b67">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left">
                                <para xml:id="para_7f8ac421-8404-4745-b361-5132042ee856">Row 4</para>
                            </td>
                            <td align="left">
                                <para xml:id="para_60a8e871-4ba9-4328-aff3-e713472885e1">(Through <xref linkend="sect_TID_3819" xrefstyle="select: labelnumber quotedtitle nopage"/>) may be used to encode any significant hemodynamic numeric measurements. For reference, see <xref linkend="sect_TID_3550" xrefstyle="select: labelnumber quotedtitle nopage"/> and <xref linkend="sect_TID_3560" xrefstyle="select: labelnumber quotedtitle nopage"/>.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3814" status="3" xml:id="sect_TID_3814">
                <title>Left Ventriculography Findings</title>
                <para xml:id="para_2df747c9-e377-46c9-9f4c-2e57e67386b8">The information contained here about the left ventricle is relatively qualitative in nature. It is a high-level summary of the more detailed information that may be contained in an optional Quantitative Ventricular Analysis report. This Template addresses findings about any ventricular septal defect (Row 7), the myocardial wall (Row 11), and about the aortic root (Row 16).</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_b3f4bbf2-3e52-4bb1-bdf8-e6cc28a58bd7">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_6f75f6c8-2a67-47f9-9ce1-c5bd5cfb992e">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_90dcdde9-ef1c-4876-bd5e-d2ecd8ef5dbd">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3814" rules="all" xml:id="table_TID_3814">
                    <caption>Left Ventriculography Findings</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9ac59f88-e0fc-44b0-9aaf-fb02e0d21175"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_822a89ef-93ee-4edd-900e-c478c14dc710">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f77b1916-8dec-45cb-9cde-44432c2e7bae">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_405811a6-ba62-442e-87b7-19b588825901">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d63ee02a-2e9c-4392-ba51-b86c10227ea8">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_58e1ce56-2605-442f-9703-c36af7ea8bea">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f3cba74b-069c-43a2-a0d0-b80967d97dc5">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_93cbab80-1e69-49dc-9cce-72d71586c829">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_76a91188-1a98-48ac-b83a-b443b811d10b">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8ff5bdb-8068-4a6b-94ea-5c50302114ae">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f99f130-3bc7-44b8-a4f4-b60c0bfa95a7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f5a70e2-9962-48ae-871c-ec17141f5467">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_943cad04-3c20-420b-98c3-b562cdc628d3">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7dff52e-367a-4722-8aa6-ac0ec1e588c7">EV <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3cbf2e71-3487-4abf-8e50-4a10e5532883">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_58b00d2d-c0f7-4798-b4ec-89112a63d0f9">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00b87249-17f3-49aa-b5f1-aaa3c97ed55c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_60fd82f6-6ea7-4253-8f53-ec2b7414640d"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_07a4ac72-060e-46b9-9d81-9c9d0a20b73c">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dde91dee-1b58-401c-91dc-38f1a3d582fb">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_949dd5f0-fb22-48f6-8a76-ed607becbcf3">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c579f4cf-0692-467b-8a9d-cbdc5fac8c51">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_db5c9495-6be6-49c7-be54-39c3394730e3">EV <link linkend="DCM_121058" xrefstyle="select: nopage">(121058, DCM, "Procedure reported")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2cbd8477-b3e0-43ab-8e5d-398086309633">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_380590ce-79a9-4af2-9690-301b7daf6004">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f98752c-e311-40f7-a54a-5289066d7f54"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d8b299e-0c35-4756-b813-5ddb90b521dd">DT <link xl:href="http://snomed.info/id/265484009" xl:show="new">(265484009, SCT, "Left Ventriculography")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5ae3321-6d96-4bae-b073-f8cb6e485b3b">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93c219cb-3e2b-4700-b63e-70a7ac2850b1">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6dee079f-c127-4c1d-8be0-4a7a509dfba1">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_705fec62-8974-4ce2-8c84-c76c2467d278">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_77d83183-ebec-4da4-8f94-4e5da6d18c6f">EV <link xl:href="http://snomed.info/id/366188009" xl:show="new">(366188009, SCT, "Left Ventricular Function - Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fafb9a29-cf67-4938-9265-f192225be89d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9337f951-121d-4eee-91fa-3c3b2808d00b">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba0b0fca-ffed-49a9-a26f-10c4811e8bac"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f1edbcd-998f-427a-8895-91b7cb6772c2">D<xref linkend="sect_CID_242" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_18c317ec-d587-4bb6-b392-dfef41c33410">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98fea887-fc26-4021-b811-2a32015e3210">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb849881-29dc-410a-956f-6633b6c9086a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_053926fd-e5fe-4629-b511-55031998e8d2">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58387ffe-95ff-449c-9190-1c85b048edee">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5e0ad271-e6a5-4f98-b48b-764fe91fefe8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8078848c-d812-4682-a333-54f69a0abbe1">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0f394a3-50f8-4297-be10-cf1331145fb4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1593331-6805-47ea-9d4e-f24a154ef0fe">$Measurement = EV <link xl:href="http://loinc.org/10230-1/" xl:show="new">(10230-1, LN, "LV Ejection Fraction")</link>
                                </para>
                                <para xml:id="para_527824d8-828b-4c64-89f8-c314c1850a57">$Units = EV (%, UCUM, "%")</para>
                                <para xml:id="para_2274e378-9830-4502-8c4c-acd3e9ef52ef">$Method = D<xref linkend="sect_CID_3748" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_02050cd1-ca89-4ec7-af00-eee0b9d806f3">$Derivation = D<xref linkend="sect_CID_3745" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f23d888-6fa9-44ed-8d29-52c5bbd31df1">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86cea3f1-6730-452d-b579-67a933038816">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b189c9e6-280c-4bc2-8773-6a85555443e3">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29036c9a-099e-4500-8f64-c1eda9146038">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cecc66b2-3ca8-421f-99e6-bcb5d60b1d65">EV <link xl:href="http://snomed.info/id/250929008" xl:show="new">(250929008, SCT, "Left Ventricular Cavity Size")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_303f8a9c-69f7-4287-9bd2-f737a0581dbd">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_26b638d2-e6a3-48ae-820d-7433e4f4451a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_abcb93b2-ac10-4073-be70-999a00214324"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d29fbb0-c156-4808-9dff-2580b13bb202">D<xref linkend="sect_CID_3705" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_14c1075f-4ccf-45dc-90e5-26d8fd19a648">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb7b9441-bdf6-40dc-ad40-a03efc47fa6f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8850fe74-bfdf-47e1-9423-2d59e0c7ce2d">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c6c4dcc1-22d8-45e0-9caf-b3425904e026">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aef6d502-7789-431e-9a37-5dbf163d48e6">EV <link xl:href="http://snomed.info/id/250909007" xl:show="new">(250909007, SCT, "Left Ventricular Contractility")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_40cfeaea-7928-42e1-a57e-7ca1f6826c07">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f7bb10ae-b84b-4f99-95b7-945233e39d93">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_023f64f4-30b3-47aa-8064-b6ad202e3bc3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_251ec90c-b46a-4718-9710-b0bd03c0fe7d">D<xref linkend="sect_CID_3706" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd54da5d-bdc2-4692-8e53-1d6cc86dccbf">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5930fb3b-540b-4c48-b161-61531cc1a187">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c5689dc-382a-4721-a0d7-4fea68ab204c">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e1806848-b62a-47a0-a34a-07fea266bc5e">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd603ae1-34dc-4455-9e40-cedae9d7354a">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1e19f4a1-f890-4136-877d-b4c702e3c577">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_caf41d52-ea53-4161-bd5e-a4cbce5c27c2">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d324dab-7b21-423a-b878-20ad09f528f7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62fed911-65b8-4c51-ad37-4500436f6cdd">EV <link xl:href="http://snomed.info/id/30288003" xl:show="new">(30288003, SCT, "Ventricular Septal Defect")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16c8ae56-0521-4ad7-b86d-bcc2b2e59097">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93b4af8f-609a-48d0-a7f9-e68062a7b3c8">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8504f178-6daf-467b-bd5e-22edc55663ea">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42dc983e-c262-4123-ab74-c7ed575ae734">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d75c4c85-5a67-4504-8c57-9db5956f444b">EV <link xl:href="http://snomed.info/id/116676008" xl:show="new">(116676008, SCT, "Associated Morphology")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c23d75cd-6b73-4947-8bc2-10116e3777b7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c2774d90-2fae-41e3-a96a-669a7c4390cd">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e0e576d3-9a6c-4b4d-905b-d37e75c45c45"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee80e9fc-fc46-4d00-a96d-1817135991e6">D<xref linkend="sect_CID_3707" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31c7c8b4-6c22-44ef-8220-ef982df8952c">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_90b57d5c-79d4-4bdb-bae2-6760d4beaecd">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0361140-7967-4a0c-92b2-ebfc48426da9">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed3f7d71-6b78-4cf7-96ee-693ae89076a4">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce8fff6e-140a-463a-9229-506d6c83f284">D<xref linkend="sect_TID_3816" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a8443ef6-52c0-484f-bed3-c032147c1512">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_034fda2c-e7fe-42e7-b5fb-28dfc344d137">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13aea143-fa37-43eb-a978-147f94175cbe"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ba783a9-32a8-4d9a-889f-3d00c91ea43d"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc95caf0-551b-4747-97a8-3c08729c72c2">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_890b5808-feb3-45b0-adb9-b7358e43d90c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba2e7159-defe-4102-9c6d-5ceab8c6af2f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e24a5042-5c42-478b-b939-325dbb9d209c">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_01a60ad1-babd-4ddf-af00-06611a68e855">EV <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_79a8cecc-acbd-4cfa-ba14-17c30b6b339c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f33cfda-6259-4a28-a286-186523387f40">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dbbf5bd0-fc6a-4fd4-b054-ae3fabdf9b07"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05e177c6-2eb2-4d59-97d5-0092c486438a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8c9c8df-e37a-4ac7-8c75-1f1b685dd6fc">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fca1e8ad-9cee-47ec-bfbf-354c0196aa80">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_edf3f969-419b-4569-856a-372cec2d9aad">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ce8e6c3-6e00-4c80-9f17-f5139a1965d3">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc2f3caa-4878-4619-a549-fa2452ace588">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6422b837-c3fe-4b7d-a205-323cdf20c2bc">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d3ecfdb3-5f78-4d3e-9057-c5011b408d2b">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98e4523a-28c2-4582-a9bf-fd17e4b8b404"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6d86e3c-169e-44de-9b46-5176914425c3">DT <link xl:href="http://snomed.info/id/272657006" xl:show="new">(272657006, SCT, "Myocardial Wall")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9b09da9-88e6-446a-9c33-4f1ad8824d99">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c24e7d31-4ead-4608-b0c2-7adfd6e95b85">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_437e1156-2567-40b6-a564-e77517077d70">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc272b53-ffec-455d-9177-428e2872dfa9">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35f605c0-d41c-473c-a855-b2a67c931cf0">EV <link xl:href="http://loinc.org/18179-2/" xl:show="new">(18179-2, LN, "Wall Segment")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f99476e-bafa-4ce2-bce9-dde663569d8b">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2563bd80-b698-40a5-80fd-3e580000b857">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1853a50-8ce7-44cc-9ab7-6554795372ac"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8ff7a2b-8382-48a4-b3bf-db613cd45a81">B<xref linkend="sect_CID_3717" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea84bc61-846d-41ff-92ff-244c9a7614e8">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55397dde-9690-480a-9cb7-8a3771956a72">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8006e9bc-0856-4a5f-8ca8-1ec0b185b6b3">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d00762a-3758-4ac9-a241-62c157285a7b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c7340d2-e73d-43d0-947a-70e7440402ac">EV <link xl:href="http://snomed.info/id/60797005" xl:show="new">(60797005, SCT, "Cardiac Wall Motion")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_608867cd-16e4-41be-9841-820f861ee870">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f944a920-c03d-430c-b571-b0870b9228a6">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ebd3542f-a021-474b-a81b-3e8800a0b8b8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eadadb2f-dc04-4769-b6bc-b0d999867e02">D<xref linkend="sect_CID_3703" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8678d22a-3cc6-4e9d-a473-4b564b3f0a40">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa76b70b-4254-4190-9dc4-fb0ed4ddb604">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_397d0fdf-ecd7-4635-b3b2-5c2e2efd7dd4">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82a49999-ca9a-4c3b-ae44-7065c0b6df11">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_648e5963-5993-499d-aa12-9366961a37b5">EV <link xl:href="http://snomed.info/id/116676008" xl:show="new">(116676008, SCT, "Associated Morphology")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0e921898-92f9-4276-be73-6618fe155452">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8353f3fb-a125-4c46-a479-f3afe55a3fb9">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6427849e-2a82-4dbe-83b5-ef0422a81852"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f3cf076-df6a-4065-8e52-c295c8a84c18">D<xref linkend="sect_CID_3704" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a284021c-e998-41cd-ba97-6504b4ad0012">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a01c2d8-233f-4583-abfa-cc714a3a0e82">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_309f32af-8cbc-4fde-ae2c-6258a0513bb9">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5d04670-43ee-422e-a814-b9444a9b2773">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf5bc6c6-10cc-4bd8-ab92-8de11e13c043">DT <link xl:href="http://snomed.info/id/246262008" xl:show="new">(246262008, SCT, "Score")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bdc0f5e5-7bcb-4039-a5e8-cd473f5dfba0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a30ccc64-d223-4fc5-8e89-4be97247d682">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bed51e26-8215-44ba-8ac6-81e9c4d25b1b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b78485a-0ded-4787-b356-0066ef3387db"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b9acd97-ed47-4931-82af-9647eb609a92">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_868a4cb8-f028-4be3-ba02-dc43590158aa">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb85b298-d589-4154-b7b6-f9e11f4895f1">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_12a5f4f8-9444-4ca7-a4a4-2694377fa425">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9b8382b-9820-4df0-857e-8bc15c3cd336">EV <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b2ed6581-0c19-4854-a282-c329dcda8ec1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dd88b54c-ee24-4088-8542-dddc8371d06d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_513d24be-99af-4287-b405-1daa2ea45998"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dacd6ff6-565a-4d87-813c-045df5574cb7"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c9bce79-5d75-4b61-80dc-eba94e50d62b">17</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d12e09f-71b6-42f6-b906-5ad6fdbf42cc">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65206df0-2c66-4b4e-90e4-a22c7649a5fd">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a67821b4-32f8-4193-81cc-e62c3e4ea2fb">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7284f1ea-a6e5-4e5c-844c-fbc0d41da5d0">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_99b7338f-662e-44ed-814f-25f0b959dfa0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0fb56a03-21ff-46ce-a853-b5389c2cc13b">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_702a4a2d-2ad6-43ad-864f-1c5396697f11"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf77667f-83d9-4aba-b118-153a90dd764d">DT <link xl:href="http://snomed.info/id/364091008" xl:show="new">(364091008, SCT, "Aortic Root")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a472fb1c-1a8d-4ea6-bd9f-c8037a80b2bd">18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_121ba12b-9b48-4e61-9337-4875d1ff2478">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1146ee3e-a8b8-4d6e-a577-630984a153ce">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a07a2e61-baa5-4a20-847b-2a212331900c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c0a966b-3054-49fd-8a3d-83b16d9dfcbd">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b803d7ea-7aaa-4b2c-abeb-f3016b37f818">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d104809e-8fa0-4477-a0a6-296ef4de2782">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67717e19-34bd-40f1-a087-4b356059b166"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82043ef4-3c73-48c3-9baf-5a439d5c94ce">D<xref linkend="sect_CID_3709" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3815" status="3" xml:id="sect_TID_3815">
                <title>Right Ventriculography Findings</title>
                <para xml:id="para_900263dd-7f9c-4e47-9832-83fb40404b89">The information contained here about right ventricle is relatively qualitative in nature. It is a high-level summary of the more detailed information that may be contained in an optional Quantitative Ventricular Analysis report.</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_0897a665-5324-44b5-bdcb-fbf26a10bef7">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_118b5c93-18c7-4c58-94f8-7093fc951cb6">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_15216a3f-3df3-43e3-b198-f8c6dbfd3d7f">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3815" rules="all" xml:id="table_TID_3815">
                    <caption>Right Ventriculography Findings</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c162bda4-b862-4aae-9ce0-c4ffb4a0bc85"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e30a9aa3-ecfb-4162-960a-4a59c8e0cdcd">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_edfe7f9d-1764-4c99-b1e8-c82f1f7c1df4">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d924d3f2-624d-429d-8645-76ad61b6cde6">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5dc076d7-4346-46dd-ae56-978f5f2766ad">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b1067b88-6ec4-4d24-9efe-28c18bb992e7">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9e1311cf-1d3b-483f-aa25-0c2dfbdf4a9f">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c5db14bd-db25-45cf-b047-fac7fb6a045e">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_db9db022-d4f5-4f25-99da-2665d8815d51">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b338a37c-ce84-4b8a-b195-37c51cd85750">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22b5c13e-bc76-46a5-8835-519648ffc6f0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1fef55f4-50fe-4b2c-9a8c-c30f498986c0">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c4839b45-8d5b-48a8-8ac7-38cf23bb07f1">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3cf61657-77cc-4bbe-bef1-dab961714243">EV <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ce637ac-27d0-46b5-921f-c9d3090f58d5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c861a515-fae3-4c6f-97f4-4f0ab7e50e5d">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_476682bf-2bc1-4c24-a3c2-ead27027d2da"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dae32d41-767a-4f92-be49-e045be4203a4"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fefa9c71-392b-4c74-9e54-97a3d8f402c6">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e5effdc-243b-4119-9527-df298b56a59b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e4de116-58c3-4e3e-89cf-a5150c2faf26">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_618532bf-9b34-4c75-9c94-dcbbc7198902">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0247b9fd-01cf-418c-a32c-9e4c5cfdca92">EV <link linkend="DCM_121058" xrefstyle="select: nopage">(121058, DCM, "Procedure reported")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a34be046-315b-4533-bef0-9a28f89b95ce">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3ade1522-696f-472d-928e-d8a0069734a8">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ce34ac7-312e-4a92-b075-e3078686a9bb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1b961d2-f9ab-454a-b975-55c7d10b3657">DT <link xl:href="http://snomed.info/id/265483003" xl:show="new">(265483003, SCT, "Right Ventriculography")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55523696-e4cc-47f6-8886-d965309d2384">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e001b46-c842-4750-a91e-074726a73135">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_127992de-ad59-4fb5-890a-8ba3cab49ebd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3369a4f2-112e-49ff-a7de-bf722b1d06c4">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72f9f0a7-6b5c-4e09-8682-fda757e21d67">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_af030df4-4e9a-49da-8a88-f080e6e0801e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b52f9d71-ed58-4a8a-ae3b-d79d2cec8b38">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_046a883c-7078-4ec8-aeb9-57dd3f62cffd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26e7ba92-e7a0-4128-9e1e-8fda61b39b65">$Measurement = EV <link xl:href="http://loinc.org/10231-9/" xl:show="new">(10231-9, LN, "RV Ejection Fraction")</link>
                                </para>
                                <para xml:id="para_47836acf-156a-4c51-ab9a-a61819d66955">$Units = EV (%, UCUM, "%")</para>
                                <para xml:id="para_77411fca-377c-4ee8-9c0e-a8a6e932780e">$Method = D<xref linkend="sect_CID_3748" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <para xml:id="para_00cbf371-2bfd-4529-a98a-64ad126b6cd4">$Derivation = D<xref linkend="sect_CID_3745" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7aca4dbf-a31d-4d2c-ad4d-bd28b0842b42">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a95d076e-110b-4cb7-a669-46560892fc38">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c97d90a-7225-4a5d-af78-b60d690dd220">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_983c6ba8-1b31-43ee-9511-6aa9d4964953">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2fdd3bd0-7bb3-4762-b741-8d886dde1365">EV <link xl:href="http://snomed.info/id/250964004" xl:show="new">(250964004, SCT, "Right Ventricular Cavity Size")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_18b2338e-f1dd-418e-b82e-cc7b82123850">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ab94f1ab-f180-4645-b80d-4000e59dea1a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3cfb7be6-8ef6-4505-9f37-17601476e261"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e0d9b984-e964-42fa-9d58-86ee9914aad6">D<xref linkend="sect_CID_3705" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac538f5c-1e4e-4551-9b8c-4cbb46f5ba98">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_629429fe-07ac-478c-88ff-d92c82a4cd68">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f897fdde-e783-4848-9bc2-7e90bd5efc1b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cca6def8-6dc2-4b40-b9f2-80f7b86adcf4">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f29aa86-6fb4-48d5-8381-d4c855f9f4c7">EV <link xl:href="http://snomed.info/id/250949004" xl:show="new">(250949004, SCT, "Right Ventricular Contractility")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5248625c-d0c8-4faf-a3c4-d6abf4eb2e30">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_39fd8204-7516-4adb-8d6d-23cfe9f128af">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_811485c1-f48d-46c4-b5d8-b2f3dab0bd43"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6373c43c-4a7f-4f2d-9c61-479ee3f966a2">D<xref linkend="sect_CID_3706" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cfe818ec-f978-458a-9b44-ddc4cfb0a8a6">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67b83586-975d-42fa-afc8-2f2341af98c1">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5779f366-b295-4938-b0ed-dd80d0f0953f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1582ce29-112b-4a5d-9948-ac240597ab62">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cbf41150-d831-48e7-b304-dc51dd5ffda0">D<xref linkend="sect_TID_3816" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d205ee6a-d720-40d9-ab54-d8b4e0f87b09">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ec4aa0f7-254d-4f4b-9a6d-170c7e9c7fea">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_954c089c-dcd8-4972-a1cc-33f4326b3946"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10bf7a10-b899-4988-b347-2747e2700c11"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3816" status="3" xml:id="sect_TID_3816">
                <title>Ventricular Assessment</title>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_c1571d9c-3758-4bfb-8804-fba226ebf477">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_8f4441be-aa28-4cf8-a6b4-5b4ce44ee270">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_97732852-713b-4cd7-bfb5-82660829ed6d">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3816" rules="all" xml:id="table_TID_3816">
                    <caption>Ventricular Assessment</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_797cf633-2596-4153-8e95-dfa37c775641"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_091c943f-269a-48ef-9b63-be108cd55f8f">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3013b067-2d67-4879-8b6c-7eef4669db41">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6d0560aa-5c85-42b4-82ec-00feae1b2c26">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_08a1a22a-2994-472a-8514-c462a129afd9">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_be9a3b27-40ee-4b3a-a86f-4e2ada937b4e">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_25fd9094-5be0-4431-8968-0988532aaec5">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0e82995e-6178-4c22-bf1e-31e0553792fe">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d504d1da-5f2d-4d4a-817b-0b0dfd7f54a5">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9cc8407e-9b5b-4e7f-8cad-8d2c140a99ce">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_552276a9-6fc8-4365-9ebc-02c443fd603c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f036a84-4126-4cb7-90e1-664453f3f8ff">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5771c9d3-2cda-4e84-88d9-c224a2553aa8">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5701bbc6-5380-44f8-a184-eaa7ba83ea5b">EV <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f8c67361-58ae-46a2-bcf1-e1259d84cdc7">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_33e26555-5feb-4a23-9195-29799b2c925b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0feb62df-afde-4565-893a-c8f68da43709"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b7dac06-3e31-4b77-9717-4e870a0e678f"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1d75213-35f3-4d15-93ab-41cf2b5c9b02">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_285e320b-42b0-4bac-83fa-ad24ab153a08">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37eccd17-d716-4008-a997-09270743f6c6">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0881d17b-9597-4d6c-9d35-4820b07611c3">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6945a07-ec04-44fd-9f74-37c0ce30e990">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0b8df8fc-bca3-4a63-95f4-7018b65a2144">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f5da5aaa-03b9-453c-9bab-9fe4f9b5e306">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6737d79-7480-4aca-b51a-95d165e5dc79"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eef0f5cf-94a0-4851-a14f-8317d92b8f6a">D<xref linkend="sect_CID_3701" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_136ce65f-06e5-4638-b5ba-80512564c196">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d764e18-90b4-4dcd-ac62-d1ca69303c79">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09c3a64d-9fdf-40fb-a9a4-fcf4841b5ef0">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51c17808-042d-4e1e-a647-15bd3e43caab">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54260484-e0de-4d2d-8954-2f7487ce9f7e">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2cf6e022-dd21-45ad-a63d-5e57da40aa25">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a25cb95e-68e2-4521-b561-273f3ada19ec">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_329d3d5a-2969-4f4c-957c-0de3aa5338a0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4186242b-5623-4049-91ee-a7fa927846b3">D<xref linkend="sect_CID_3711" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c50e229-5a87-4927-9ed3-24381cb5f174">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e58b10a2-639d-4b43-ab28-da778fd92763">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_936fa455-e92d-458e-8fd0-d9aa72feab10">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61493c19-2f51-4565-973f-1b44454f90d1">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_07e8dc91-46e8-49e1-bbc2-97790890c579">EV <link xl:href="http://snomed.info/id/246112005" xl:show="new">(246112005, SCT, "Severity")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_76affee8-e426-4d74-9dcb-b423d14a74a6">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4343ff27-5994-4eae-ad65-171cafecf97d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf4b863e-c036-4e08-98e9-bacfa3298a69"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee88d13d-1adf-4636-9b4e-5c437464cd87">D<xref linkend="sect_CID_3716" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5678af7e-cddf-48e0-94df-2a069db783df">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b4e0d95-6025-424c-887f-9dce3117ac89">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_45274ee5-46be-4806-b8d3-3a8e5c577c14">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f6f5555-3b53-4056-b60c-097fb684c575">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_897b0b82-2715-4ef2-8387-d9e944439d1c">DT <link xl:href="http://snomed.info/id/246262008" xl:show="new">(246262008, SCT, "Score")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ff897ea9-a1d9-4cf0-82db-05589275262c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a08fc13d-612a-417d-8632-b336b706d4e2">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d975934e-9151-47c1-a84d-aaaa96201ea3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8796df70-c8f6-447e-9b7f-ee2fa801a1d4"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ece21099-e059-432d-9bd9-89e08516b3a4">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3183e8d1-fe12-447f-907c-7d1e839d9dae"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2999d2e-3b71-45ba-9adc-060d0e951c6f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2fc0e971-ef29-4dae-a33e-4ea27974685e">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ad768f0-16c9-4c6c-96ab-27e31dafdb94">D<xref linkend="sect_TID_3819" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2ea1269e-6975-4d39-aebc-fdb9f012da96">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_40b01bad-45ea-4965-bd79-2baca3911f62">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1a450db-9ff6-4602-9f25-4a638bc1f868"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_56b41125-2e06-4f61-adee-b27b04188016">$Report = DT <link linkend="DCM_122292" xrefstyle="select: nopage">(122292, DCM, "Quantitative Ventriculography Report")</link>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3817" status="3" xml:id="sect_TID_3817">
                <title>Coronary Arteriography Findings</title>
                <para xml:id="para_ccb7df2d-3993-472d-9deb-491067c90b87">The information contained here about with regards to coronary artery lesions is relatively qualitative in nature. It is a high-level summary of the more detailed information that may be contained in an optional Quantitative Coronary Arteriography report. This Template addresses findings about the individual arteries (Row 4), and about individual lesions (Row 9).</para>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_e594ff00-b28a-4cbf-b13a-84122a783df1">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_713c5078-4df8-4197-911f-e72c221a8376">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_cd59e2d6-cefe-448f-b92e-20c413c35821">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3817" rules="all" xml:id="table_TID_3817">
                    <caption>Coronary Arteriography Findings</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d1615ee-856b-4821-8816-4472b2215e18"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fdb5fef6-bdb1-49a6-8845-2be9ca6c4f2e">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_236d9e97-1437-48a1-b732-c35bb2ff64f5">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_87e859bb-c4e8-4ea0-87e5-d3f7287cc952">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e9bd1508-459e-434a-8016-ab42ba19f64a">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2fab2057-5423-47cf-8b85-d9c816702467">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_433ec2e5-5cf9-4e69-b3c8-e7956e648e92">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9e8b7777-2a0a-460f-97d8-1c8b544a31ca">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c4241af1-ea23-498e-8252-80bd0bbc4eee">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f008f24-d85c-4fd5-a5ac-df3b3bb66b39">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_328e61a5-30e0-4b06-aa1a-628729919a4d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7c716f6-e9d7-4964-a2be-01f55e633271">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2ebc2c5-53c0-450f-bdf8-a9e08208f087">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fdc1362b-d306-42c9-b834-69897dfe4ba0">EV <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ef7c5e7d-3df5-41a8-8c93-a69fbafa4545">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e4834815-a8ed-40eb-8da4-21bc0f601e5d">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fffaca41-2e9a-4d10-bf39-7df8f6aa519b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a25a617-987c-4944-89ca-d6e543de7cd2"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fea14b71-2fc8-4bc8-86bc-881f8670b7f4">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c26ec47-445c-4988-b7c4-ecee9ccbfcc9">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0013545-c9d2-4c9d-a852-f1710d797071">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2272b44-8fbf-4aa5-879e-639d448ce9db">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5dd9275-1b27-4269-b2c2-f7e41f6405ea">EV <link linkend="DCM_121058" xrefstyle="select: nopage">(121058, DCM, "Procedure reported")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_59896b33-9017-4848-8f23-6a990acd6c9e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_788201d4-3238-4caa-a11f-453b8e5b5f91">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9689736-2d10-4b3d-97e3-6e5e2e372a48"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff234a6f-4e4e-46e9-8694-6dd84dffe2f9">DT <link xl:href="http://snomed.info/id/33367005" xl:show="new">(33367005, SCT, "Coronary Arteriography")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e0ea5f65-bf60-43f0-ad21-aa2701ce03ec">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5b397c7-550f-48d5-bd9a-18efb950e922">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_34c54b87-0ed0-4992-bda8-66e9e92751d4">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b275ae73-19d8-491c-ab1d-ce81c171ab5a">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd963dde-28b9-4560-bba8-7e46524da9e7">EV <link xl:href="http://snomed.info/id/364092001" xl:show="new">(364092001, SCT, "Coronary artery feature")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2fb0c4ca-7e36-4acd-93e3-83e54dfb322b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d003f83-3705-4948-a9d0-85cf873af54f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_273dd56f-5eb1-4fd4-89fb-5e5a26590820"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a643a68-3715-494b-86f6-6ae13dcbfa70">D<xref linkend="sect_CID_3710" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98974655-f3c8-43b5-a263-d0a4e1fd56a3">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0a5797f-2143-4d45-89d9-93135c00e428">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dea63b7e-0be6-44cd-bcf4-325bd1880377">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_770e79de-8164-42d3-b5f1-05e79e2073dd">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80caa327-6ee9-407d-adef-1467f83f70c6">EV <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_599706b7-5fbe-48e1-aa8a-60f67a017274">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e017df70-dd8b-44ad-835f-28c94a3f8cde">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_423a547f-f53d-4988-8044-e7ca6fe45ecb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ddc5715-8f3a-4207-8ce7-9fd78622bd4d"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_60c0dc40-6d9a-40b1-b176-9f37fd02c490">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3fc5bee-e45e-4da6-a749-a78205a33d51">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f1e7e9a-4be8-4238-ade3-b36cd30f60cf">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06f3595c-402c-41cb-bb95-9d39344011b2">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_68cff526-ed88-49d9-b170-d25db0f7e74d">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_be1f1112-bb70-48c5-a0e7-0bb994dd957d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_16410e7f-5015-4b64-9ee1-703806dd271a">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c28576ec-8d9e-41a5-a454-04196374706f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e5f891d-a6bc-4dd3-a186-d5a0ead2b987">B<xref linkend="sect_CID_3015" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b85937b0-2b3e-4c82-a70c-e7d8a12cee41">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2d72910a-1fad-4d0f-9b4b-3fbb16876c9c">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_23e9cda5-ae3d-4a54-b484-0a1256d7cdc1">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f19cec49-2cf3-4f9f-b4e9-e90f80510bf1">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_033209a6-aa83-4ea6-8565-dbf9e59a1e22">EV <link xl:href="http://snomed.info/id/106233006" xl:show="new">(106233006, SCT, "Topographical modifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b95c854c-5874-4604-873f-5b5dec2134a8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_109509a1-2d7e-4f80-98d7-6990e1fe4f2e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d7b1a35-f4e1-4bc4-bfbc-5f4bdb2189c9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7670e00a-da0a-4c62-afbb-f30999b2c33b">B<xref linkend="sect_CID_3019" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_40f5a63a-4fd0-49e9-8247-de6db53fc2ab">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51412a4e-38d1-4a62-acf8-99be824bbe1f">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8685805f-5b71-4e2d-b0e7-b453eec4be59">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e486bb7b-f8aa-45cd-ab41-ea2f88a42f75">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4a24113-664a-44f8-9d38-80c719d57b90">EV <link linkend="DCM_122134" xrefstyle="select: nopage">(122134, DCM, "Vessel Morphology")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_650e7275-7103-4bbf-b753-9a5ce2be9b6a">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cfd9804c-be41-4f5f-8b54-3de58af7c32e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a26fbfb5-28e1-48f7-b52c-4b11d7fdacc9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_66f0b808-b06d-4a99-8557-8b0090d2db27">D<xref linkend="sect_CID_3712" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_294737bc-e25d-4924-b59e-e096cfb5ad49">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06d24ecf-46f5-4637-b3cc-ec52d436e4d5">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59218560-31a5-459a-bfe7-5115d523975c">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e0d2ddfd-2f62-41e8-b736-1acd82b633f1">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_811253b1-70c0-4594-b437-d80356f0d022">D<xref linkend="sect_TID_3819" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d718c298-480a-4d68-aadf-3056dcc40536">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7a139b5f-0384-4ce2-ae4b-210a0bbe9f93">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_751eb1ef-8d66-41a4-a28f-5c25d4cc5306"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_78f1f1c8-ef74-4018-a673-77e96df2acea"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62d4a779-f2ac-4c2f-9ba2-8a7e35bf732e">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_102363d8-495a-459d-830f-20df985e7bc1">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c90a1f6-c113-487c-8d9d-6a4caf56804f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16f07ff1-e93d-4237-a0fb-c4d9d437c7a7">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2db9de71-0a89-47b8-ae42-88daf00878b0">EV <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5d2cc2e3-3337-44a5-91e3-974a2e4bd7aa">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c7a0c140-9498-4c00-96ef-66e065fe2024">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_686aaa90-138e-41e9-8f29-fab1aa70153a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b69f434a-8f26-4083-861a-d2cef9198459"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d61330a-a1c4-46fa-a16c-cc961c7ac1dd">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_466f890c-ad7c-4936-bbf7-e6482674f78e">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9c89ce5-f7d5-4aaf-bbfe-0085c7fb4ac0">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4ea08b4-4004-4ef9-9dc7-7087b8629383">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4124853-b7af-485b-9690-924d6ed8afa5">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bf6bd702-7344-4eec-8b1b-965c5253c9e2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_57f62f5c-bfe0-4722-99c7-ebea884d6e0d">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_282f65a6-1f8c-4e3b-a30a-3baf3d48976c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ba1df6e-8a2e-42d2-bfc0-4c124be1ad96">DT <link xl:href="http://snomed.info/id/371895000" xl:show="new">(371895000, SCT, "Coronary artery lesion (culprit)")</link>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e9d03b7-9c48-4681-a1c0-430c45cd0089">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80c4c218-2e31-4857-9844-2f42207326d6">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f798b44d-8407-4600-bce0-f4717f3fdd89">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b491d597-6839-40b8-a28e-f595bfa10a8c">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ebd493d-fa64-4ec8-abd1-12067c0c5414">D<xref linkend="sect_TID_3105" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f09c3e07-181d-48e1-aa70-883b0f617b01">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_652243f9-f999-456c-962c-f33c83931fca">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_283b1874-37e7-4f2c-afc2-f6ce254d6374"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c2fd758-35b6-42ec-b7db-a7fb39633dca"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7a109dd2-c899-442f-83de-cdf4d4b15a91">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d10a5c7-d0ce-4a59-af05-28861f79a4d3">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c3c6d3a-526e-4f6b-8ea4-25a114bdc51d">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_920c6a62-2db0-4d4e-a3f1-adf66c524b80">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f270ee2-1c3b-4fc3-8cc8-e05a5f20f5df">D<xref linkend="sect_TID_3819" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6bc677a1-0dda-4f4e-b671-2988097ef360">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_133124e2-9bb2-4b9c-b399-6ebd56e723b1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2175811d-83eb-4be7-90c4-0778017aefae"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d6d4e42-6346-431e-8794-adfb78fab605">$Report = DT <link linkend="DCM_122291" xrefstyle="select: nopage">(122291, DCM, "Quantitative Arteriography Report")</link>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3818" status="3" xml:id="sect_TID_3818">
                <title>Other Cardiographic Findings</title>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_2a440b79-3389-4ec6-ad12-192d61f26531">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ae53ddbc-c5ae-4e97-b75d-ca89d6f60c64">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_a5049ed7-5506-4e59-a51f-412cc2d6abe6">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3818" rules="all" xml:id="table_TID_3818">
                    <caption>Other Cardiographic Findings</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_feea7865-3f38-4ca1-ac73-0aab2c4c08d5"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2f9e728b-5d27-4223-9695-dfbbadc7c93e">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a21422bd-2091-4477-8d7f-750f6020a686">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0a617d5e-6760-49a3-9e1e-c3d85dc58b54">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d37447cb-5edb-4715-9294-f11b6d6df6e4">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a6be8838-25f4-49bd-8afd-441ff8a4c3a5">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_39199aac-35b9-4177-9c3a-34e8a5dc585c">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_49bfc856-5369-4b2b-8202-be71c76b21ab">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ff2bea83-8510-42d9-815b-5636a9d9526b">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1378fcb-be47-4905-aa79-69be720bf6be">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84273160-2784-49f0-8d2d-8783c2826f72"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba5755cb-e95e-45cc-9da5-a9e50c252d22">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39ec5cfd-9d68-4655-b94b-5cd866c45a95">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb44da25-4c63-43c5-9458-72a3ab84d108">EV <link xl:href="http://loinc.org/59776-5/" xl:show="new">(59776-5, LN, "Findings")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bafc8fa8-ec6f-489e-800f-507a3cbd68ed">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6629e375-63c2-4c07-9046-c9f82d10d5ec">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88b2601b-1518-4533-bd54-f5e7dca2c973"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8bca240c-1170-4770-9337-805871fe9902"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6c76bdf-42c9-4712-ac81-1aa77fbbf486">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5097744-f347-4737-9022-051c38cc7e67">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58caca47-84b7-42ca-9895-c27307d693ca">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_db2e9a71-ba84-4ab8-ad6c-070169a1320f">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_928a61e2-8ae8-4522-9cad-1ad2048b1110">EV <link linkend="DCM_121058" xrefstyle="select: nopage">(121058, DCM, "Procedure reported")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb14a23c-cba6-4523-a3ad-21fdd0ae3a3a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d2568333-78b9-4b63-ae60-53b78eb9c5cb">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_94443933-6699-4ed4-a0da-faf20adc535f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e13a04bc-fe5b-4d6c-b2e8-7a7ac9d99217">B<xref linkend="sect_CID_3428" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05c59fe6-8edd-4ed7-adfd-bab38138b44c">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5de49f8-3516-4bc6-97ef-b49cc895fbe6">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5eb8f5b-4d26-493e-876d-ef821487b2c1">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e0bb27b-bdd1-4234-94ae-648908739484">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f37c7b0f-6b3b-4daa-b880-d6a7705d0c06">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d2667c6f-8d2a-4baf-b071-0a6e4d805a89">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cda5565e-07e0-4ede-bccc-e245569ab4d8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7547fc9-f516-46a7-a3e7-6f4301a40ff8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70a61ff6-ae76-48be-b891-58448aec3709">B<xref linkend="sect_CID_3630" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ffda362-9d5f-4ad7-b4fc-59b7466a9b7e">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5f75766-150e-4cd1-a583-3c4b585aa7b5">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5dbefd68-9352-465d-9b40-61821a62b522">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b312e918-8ee9-4c33-a31f-7e94292bd4f8">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39a39df5-92bc-4745-aeb4-923cfd6c5a00">D<xref linkend="sect_TID_3819" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85bd2d11-66c4-4eed-bd22-78a0957ae8c1">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e181f065-017e-4c1d-b83d-c0c791add3f8">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a59ca91-7941-4011-8c70-238022799ebd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9334f4df-de1f-44f7-837e-1ad6a79269d1"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3819" status="3" xml:id="sect_TID_3819">
                <title>Common Findings</title>
                <table frame="box" label="TID 3819" rules="all" xml:id="table_TID_3819_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2fc04d9b-2e22-4147-b08e-4ceb633fba43">Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_01dda42c-550c-418b-b0fd-8a980c17b32c">Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8adf124-a03a-4086-a005-21fe9311d2f8">$Report</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4413bd4-93bb-4573-b874-eb674a45c1c0">Title of composite object (evidence document) referenced</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ba63317a-d969-46bb-a2a6-1b25034bf6eb">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ad2cf02e-eb76-433e-946c-9322e1b60454">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_e23c3163-896b-426a-ad20-8978cb7b789e">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3819" rules="all" xml:id="table_TID_3819">
                    <caption>Common Findings</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_65a87f98-55bb-4b1c-897f-bf9dbb68d6b0"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_873e825e-71cc-4b31-8924-c7fd6f050c4c">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dd1f3c0d-737b-41b6-9dfa-32bf192598b6">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_46f2c8dc-0472-430d-9fd6-284727348e68">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_43d9be0c-2621-41ca-81c5-516c057328f4">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_befa7153-7130-4b06-aec5-6ccaeabc5da6">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4c281033-90cb-4acb-aab7-4ef7a7657340">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e0fe2227-c217-4e31-bead-f6f7f148b118">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_760e4470-9b67-4e00-913b-e37a8dd5cdc8">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5b88ecc-18c0-4810-8a52-18b1c078fb22">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb65d58c-05a8-4075-9e5d-b443dbc1f1aa"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a155e1d8-1303-4914-a3df-64cfcd2fc4e3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3cc79a0a-1523-4fc1-9d8f-588ec2255cfa">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25a1c370-c835-47df-8018-eff392349f01">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ac68354b-714f-4ced-a1c0-9c6b684fcd3e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3898c125-a74f-4409-a75b-d9d67baa43f8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_962da8ba-06d7-4c4c-8c16-67bb462c3aa3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3072d2f-f47c-4875-a228-1aff395c4a87"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7ec4ff8-96e9-4d66-b9d0-0da4a448855c">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc5aba52-9e0d-4889-92c6-bdcf2f97ed97"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_265e0bdd-e8bf-4f09-9dcf-ccf4d68b69ff"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1e44f07-21c9-4a59-b8c8-cddb3dca73ce">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb02c710-8009-4c3c-aac7-9597c54e1201">DT <link linkend="DCM_121080" xrefstyle="select: nopage">(121080, DCM, "Best illustration of finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_01527ec8-035a-4542-931d-1defee44107d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_532d5856-bc3c-4f4c-a7cc-0127cba02578">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce185743-a228-4d2f-88be-1ecac055dc31"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb446f66-2f81-45be-af92-191ea44df156"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fee35afb-b994-4432-9bc5-6558356d49ac">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8dd9deef-f3aa-409e-8438-b52ab5d55798"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_28394a55-14c6-43cd-ad69-72d8c980e230"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_53ffcc89-f573-44b0-ba12-0d35b95e42ce">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_025c2981-3801-4f67-be7c-63ae564c5dba"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_30688f63-60b1-4750-b8ea-d1d9c39646b1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_201faa1a-4b93-445f-be3a-5a1947c48e1e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5095b621-bb81-4146-99f9-dd378e141513"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e43d1757-d75b-4fe7-9d61-d22bb52040f7"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9cf6d983-c20f-4f40-9346-5d073a519eb4">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad8965ce-e437-4e55-ad91-f8b3a7e6c22d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87015b3d-013c-4d01-b304-26b57b2a7bfb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e82063c-e9e2-4e9c-a4ec-84db29b69c25">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd595d90-9058-4d86-8d9e-6ebe361c3437">D<xref linkend="sect_TID_1000" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_741f542e-7fde-40ba-8ed8-ca5da10d69cf">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3a39a282-7fc1-4247-9870-b889a53eb673">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2228df46-df1d-4ead-8f84-700cefcc7a80"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec969f44-464d-44f8-bc6b-157419dd4ef0"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b49e533-1829-4f23-9b30-ebc31cea0293">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a7bf430-1865-4451-b52f-8930e8d4d06f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_558a29ae-0ec3-4928-b582-eef4972a6f51"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3db6991-d9f8-4c73-b67b-f3de6c4bd8ab">COMPOSITE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0535c265-a409-4f52-9204-36808c172812">DT <link linkend="DCM_122073" xrefstyle="select: nopage">(122073, DCM, "Current procedure evidence")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d68f5bed-f29c-4794-8203-afd7ae0c74d0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6aad7de4-f30f-482f-a13a-f7c128da96c7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ecdb3ceb-f28c-46f6-9bf3-a0e11b111ab3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8301af17-8425-4ac4-9260-1ea6429faa31"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17c2d38c-16a0-4389-832f-3fdb45010ef0">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fcb89242-4249-4351-be94-b98727693965">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0d0d30e6-ceae-4c7b-bd75-5efd00b6d8b8">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4ee9364-eb32-4a20-8c26-5f5acd124064">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_490ff742-fbf7-4e13-b58d-58597b0bbe7f">EV <link linkend="DCM_121144" xrefstyle="select: nopage">(121144, DCM, "Document Title")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_38ac37b3-c295-4f1d-998e-45558c5b5c51">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ef8e1961-f566-4d50-8e08-0d533306be0c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_764fe62d-1aa2-4e9a-881c-85d5ed998b55"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bcdaacbd-3d0b-4046-b7dd-67d12b2ac7be">$Report</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_b49f92dc-6a89-4d25-9432-a4860e870980">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left">
                                <para xml:id="para_4ba62e2f-a338-4b5f-b265-f74219a45e5c">Row 3</para>
                            </td>
                            <td align="left">
                                <para xml:id="para_294b1444-076c-46be-9761-e8d8c050b186">May be used to encode any significant image- or waveform-based numeric measurements, with post-coordination of the Concept Name using child Content Items (with relationship HAS CONCEPT MOD), as permitted by <xref linkend="sect_6.2.4" xrefstyle="select: label"/>. The source of the measurement may be noted using the Quotation Template in Row 4.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3820" status="3" xml:id="sect_TID_3820">
                <title>Adverse Outcomes, Cath</title>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_2e7f453d-b04e-49a3-9e48-760bfb02db29">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_0a40fed9-8d8b-4816-b5d1-4c2b2e87632a">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_708c81ff-7531-4878-93d7-97eb01054e22">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3820" rules="all" xml:id="table_TID_3820">
                    <caption>Adverse Outcomes, Cath</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a91ca783-febc-4cd9-a3f9-5a8b23ce3e4d"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_82faa799-8c9e-44b2-84b5-81f33d1a71b7">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_12650032-8c5f-4b1a-848c-57632dfc7f0f">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_68b6101a-ef9d-4412-9745-ac58e8e05a49">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_12c706b8-0694-439d-a0b6-88b9a942029b">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5c49bd61-43a9-4a57-a005-07bce4620582">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b09e326e-d88a-4a41-bae3-9e5b2bdbba33">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_77256edf-2a3d-4219-b452-2170d20d7c5b">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d7d9952a-946f-4a7b-8d0b-a8e01326682a">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de79b0fb-4215-4347-bf8c-8ff4129aac42">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1edf0b07-ed35-43df-ba0e-3565bf6ce86d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f265a054-3a02-41cb-ad06-4e74f960942f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6d11bf2-cd97-4f9d-b597-6b69c3ab2f43">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c2f4aed-ebbf-4d2b-80cc-5cec6e4845f3">EV <link xl:href="http://loinc.org/55109-3/" xl:show="new">(55109-3, LN, "Complications")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3da77b66-8eb9-4998-b8f7-ccab53f35de4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2aa78892-e6f3-47f3-954d-3de014c324b0">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b0c1fda-e5b2-4a7d-993f-db3461979994"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc101ce9-783b-412b-b486-526648ab00aa"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93614dce-9f24-4830-a5d4-ba255c1c265e">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0713b321-ec89-4832-adc9-d23c7863db7b">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_001e1fd2-3236-468d-8933-2200ec140736">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0593c92-59e1-44b8-8a91-9ead9d087319">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_384f0e52-ce75-40e4-a846-35d32a25a3a6">EV <link xl:href="http://snomed.info/id/116224001" xl:show="new">(116224001, SCT, "Complication of Procedure")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b5f065be-afd3-461a-a8fc-0e64474405b8">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fbeeab2f-d85d-4299-ae19-491b347cf27f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cac5323f-dd21-42b1-ac15-0a4d3cd70d11"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc832dcb-1060-41f8-9003-931da5d1cddb">D<xref linkend="sect_CID_3755" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_168c8c08-fa4f-4590-a2d9-eda0c50d58a4">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0037996d-8e30-4dfd-9c23-7df38353f267">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa9a7087-bf19-41fc-82b8-923d1a4e60ce">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e017fc8b-7701-4361-b1a9-a248728e8241">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_108069e3-5935-4b0f-ab28-441f520a19a6">EV <link xl:href="http://snomed.info/id/118578006" xl:show="new">(118578006, SCT, "Relative Time")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7d2fe1fd-81d0-486d-89f4-5ac8b9948b69">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_91c43795-3bbb-4bbd-8e60-3842fb9fcd5d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c18980a3-3d0e-4098-8c96-9c9ae0783dc1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_28183538-c098-4fcb-8195-5b223a244461">D<xref linkend="sect_CID_12102" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a0c46d8-620b-4453-9bcb-1639294b5bbe">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f5f7cde-0a4b-4411-8dc5-60e26a3b8b65">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b9706816-3b9b-428b-8ea6-b789290b05ba">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_106c9e1b-37e3-4abf-ad34-34ffb385648c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8dea6ae6-1df0-4313-9514-c0b0a828ee00">EV <link xl:href="http://snomed.info/id/116224001" xl:show="new">(116224001, SCT, "Complication of Procedure")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_770c2761-5914-4c4d-95c0-3a883c0418dc">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_308265b7-7542-4d01-9057-abf54bc4f090">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9282537a-07b8-4b3f-bd45-fcef48bfd8d7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d641fbca-b6c4-46c7-8062-33c07bee18b0">D<xref linkend="sect_CID_3754" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08eda07d-6f42-42be-849d-1761fb323e32">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bbccd036-204b-4a76-b492-fe1f9e3d1a99">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e0a0467-be33-4ebd-9f63-ec486fa41ce0">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2dd9ee5-52db-4a3e-8468-a0077b15a72b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_653346df-27fa-4941-89b8-18b7530b00b4">EV <link xl:href="http://snomed.info/id/118578006" xl:show="new">(118578006, SCT, "Relative Time")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5a9624b5-b151-4445-a3d7-23297eeae144">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_62813e0e-bc4c-4ed0-b5d9-8240aaf185a4">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a1220444-75d9-4b9a-ab5d-ccc58d8ce7ec"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec73305f-0eff-4e61-a4e6-c7bc27abb33d">D<xref linkend="sect_CID_12102" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5f275f6-81e8-419b-9f9c-e159e9ffd36c">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_056ccc62-c57c-4be5-922f-86d277752e53">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bcb30356-cc38-4d37-a01e-d4ef86b2d36b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22a2d92e-3c7b-4de9-a07e-fb985d8754cd">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8f8692f-d607-44d3-a2d2-0d4acc0565a8">EV <link xl:href="http://snomed.info/id/116224001" xl:show="new">(116224001, SCT, "Complication of Procedure")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_db72802d-6b0e-46af-8f92-b994cfcbc280">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ef21aca-7dbc-46db-bd8e-16a05f02bd84">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b03529dc-5b07-4cec-8502-020869d606d9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c925c2fa-fde3-4ee6-a538-f9ae3ae4884f"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c360deb5-8a3b-432d-a43d-9bf45490a8c3">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_516808d0-834b-4830-b334-5f36bf76f53a">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dcececa4-789f-4085-9030-010d26a8f319">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea581922-86c6-4d34-b3bb-4972d4fb0208">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f7787627-c15f-4445-92e9-5fb4ae47bd66">EV <link linkend="DCM_122179" xrefstyle="select: nopage">(122179, DCM, "Peri-procedural MI occurred")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_598790da-fcda-4aa8-a7e1-ea4a472b2faa">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c46a8d4c-c43f-4e13-acf6-79a0939e406a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa2811a4-178f-40f8-8c1d-455e8906b90d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58105cef-296c-4685-9a34-45eec808aaee">D<xref linkend="sect_CID_230" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2d2dfc9-3cab-4164-b301-9f6cb94f9345">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6ee50ae-4d82-47c9-bbcb-71ffbc537dcf">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c438ce05-0168-4630-8346-6763b5b01e34">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f870c7e7-8605-4818-9ae4-da1f6962f652">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54e41e93-cc5a-4ce3-ac2c-a682fd698164">EV <link linkend="DCM_122181" xrefstyle="select: nopage">(122181, DCM, "CK-MB peak")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7dc57cb-ff14-4c9d-b477-9b2ddcfee79b">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_76f2c111-3555-4fd9-bdcb-9b63a927110d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b92fef22-6c87-4bc3-85f8-18f5e6ffd60f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5856e53a-85b7-4b1d-a42f-219ede698b26">UNITS = EV ([iU], UCUM, "International unit")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_918de55a-3460-46c6-932a-03f98f86a23c">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b8c49fc-4d25-40a2-9bd8-f283551c0b55">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb7bd23b-6f5c-4741-b792-fcc736b8ab69">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c54bbc48-b881-44bc-99f6-ebf54f8783af">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1de5504a-13f1-44ca-b6eb-1cd969f45612">EV <link xl:href="http://snomed.info/id/371933006" xl:show="new">(371933006, SCT, "Normal Range Upper Limit")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f88d7ad-fd3b-4b15-a7d8-f28f057ad876">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_65059814-904c-4e76-8c6d-be70f5373e3e">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4925149-29ef-42d5-9062-dd5ca62e574c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99481410-2013-4988-a623-e0a673e65975">UNITS = EV ([iU], UCUM, "International unit")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0590749d-9adc-470b-836a-628fbf52008d">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c24a462-8260-4ff9-ae7e-d032b11d1ad9">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_541c712b-3934-49e4-bc26-f0848e94ec66">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_005c7c2b-3684-4ccd-ba23-70a871ffda43">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c66ddb5-1b22-414f-8406-65cf4025afaf">EV <link linkend="DCM_122180" xrefstyle="select: nopage">(122180, DCM, "CK-MB baseline")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_57f36b40-842b-4766-858b-64f3d7d9cc72">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ddb68c5-7dd1-4cf7-8285-fbad68e2cb13">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_417a47b6-087d-4aec-9a81-25d01c9c0bad"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_acc38032-4043-43d3-98e5-379746a9b61c">UNITS = EV ([iU], UCUM, "International unit")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ace066ce-8301-4c5f-8c6a-d220550c6726">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25d06335-27be-4c62-9479-8fcb43aab360">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6880d457-8068-48ab-b795-32dbf589eebb">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1f9d6b60-7f56-4e6b-95d9-7f0315fada2f">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f89b88b4-df33-4a2c-b800-7c51f13f55ad">DT <link linkend="DCM_121080" xrefstyle="select: nopage">(121080, DCM, "Best illustration of finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dd4beae8-df1e-4a23-9a0f-f112c966f79e">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a01e2624-81d7-430e-885c-65262e3683d8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a0a1104-1e3f-454b-9538-5011e9e7f650"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c84789b-6ab4-4bf3-ba0c-d0784825c7c6"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_116ab81c-804a-4931-bf4e-5b34e09b8b7d">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left">
                                <para xml:id="para_593bee8a-5cd0-4c7f-884b-4c5c7cd976bb">Rows 2, 3 and 4</para>
                            </td>
                            <td align="left">
                                <para xml:id="para_4ff70d54-ee08-416b-a469-7dcfd22ae70c">Allow the recording of outcomes as either codes or as text; the same outcome shall not be recorded as both.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
            <section label="TID 3824" status="3" xml:id="sect_TID_3824">
                <title>Summary, Cath</title>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_b16caf11-3504-4bbd-ad75-b33d40a85ac3">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_834a3604-140d-4f19-a624-bae69662fd6b">
                                <emphasis role="bold">Non-Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f0678642-25e7-4702-bf7d-9167f0f40886">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3824" rules="all" xml:id="table_TID_3824">
                    <caption>Summary, Cath</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eb1de828-a987-4ff3-9d1f-405adf3427a0"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e929f7ad-c054-49fc-95e9-2a0d10d920a3">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_41395ca0-cb91-4a17-b05e-51fa2b02de81">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc568d2b-3c1d-4788-a7fb-543f9a70c578">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e60f621a-eeaa-4882-874a-b66c26178e4c">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a76ac042-1b31-48fb-9b83-61f0f85c9607">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc72f5f0-1e8d-43ad-97dd-afb71c13e8e2">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3a556248-d412-4706-b4a6-14407ecd2520">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_59f5a66b-8d47-447e-b6ee-dbf2111e6e3a">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0dd1f56e-3396-4712-8423-02187bf48730">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d7923dc0-19ea-4f2a-9159-8cd6240fe958"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c3863d82-59c3-4476-bc88-33ab36974aa9">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec88d01b-034d-483a-8dd0-f3c057041c30">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_804268c9-9766-4b4e-abbf-48c092d0da2c">EV <link xl:href="http://loinc.org/55112-7/" xl:show="new">(55112-7, LN, "Summary")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5ec0cf84-c665-4442-9d2b-87f6e67c96fa">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d7eccc6-2b60-4dfe-a434-bf67b25ad935">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22ad8dbb-1373-4378-a2dc-922492aa6129"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_152cfd36-fd5c-471b-a172-308d7e996d6a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6bee6433-d87b-4d1e-9a4d-6f5e9f82cf64">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a9adc45-543f-4dc6-a858-9c27cc3266bd">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_90b118d9-bc7c-40e9-848f-f37f98d69659">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73b6137d-43cc-499e-9744-a6f1ba823587">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8eab7189-41be-4983-9dff-da8dae24a0e4">EV <link linkend="DCM_121071" xrefstyle="select: nopage">(121071, DCM, "Finding")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf3a5704-cec3-459f-9e73-345fac8f31d6">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e1859800-02da-43f7-ac60-db654a376912">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_251bc088-a548-4f59-ba89-7d5fbd3195da"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_efeee602-f71a-4ba1-8471-f1bbc89c7902">D<xref linkend="sect_CID_3728" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ff079f0-5202-456b-b333-4cb2f9331259">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9719642-8030-4675-b21b-8fd78da40aed">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ada8ce4a-b719-4aea-9530-9f34a726ffd7">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ed5aae7-aa44-4374-a612-c5cfe2243ad6">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ead7f4d-9aa5-49e6-ae89-7e2510240bae">EV <link xl:href="http://snomed.info/id/246112005" xl:show="new">(246112005, SCT, "Severity")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5bcbdbe8-4f0a-4038-89fc-611ac33b3696">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_549f97db-bf6b-48d4-98f0-f9bb4f873de7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_833276e5-34f0-4bb2-919f-4d5816d12bd4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b55deb1f-e24e-4a90-9937-f5d78c495609">D<xref linkend="sect_CID_3716" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_60692f5f-dce5-45b8-9db2-46425eaf1764">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_28c9125d-a88a-4865-9de1-bdcc8b37d0f6">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8251abd7-76ac-486a-aafb-203a205f05c7">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd02345f-bf75-4181-8eda-71ba10b33533">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84e34f4e-7f89-4efe-8515-2b2ff3206f0b">EV <link xl:href="http://loinc.org/55112-7/" xl:show="new">(55112-7, LN, "Summary")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_47fa17f2-3c0f-4237-9dda-ac98ada4ff23">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_07aa7164-d7fb-4ade-b08b-b982fe9323f8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e496887a-96f8-45e5-829e-0ef09c6f67ca"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9c40218-72a5-4a60-8155-17e0c81faec5"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9608655-f40a-40e9-87f1-c52b4104c9c7">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_53d4945d-e4d2-4a8b-b9a9-837e33d027a3">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_187ae45f-bc0b-4d20-9bb4-e81f618d8139">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dedb6a87-cac8-4026-9d9b-00b0eb342705">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10849b00-beac-4090-b6b7-f7e0a97ff266">EV <link linkend="DCM_121075" xrefstyle="select: nopage">(121075, DCM, "Recommendation")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8cf556fd-2b4f-44ba-942c-2cc3577d9c19">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_060afd08-5c40-4315-a8f3-3945de1fb99c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_181a56e3-2886-48cf-be66-c9f8d6c956e4"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4bcb102e-b55e-4281-9a48-dfc4914371fc"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3828" status="3" xml:id="sect_TID_3828">
                <title>Discharge Summary, Cath</title>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_d7f12216-8fa0-4808-bb26-ad1ba6d6f0a7">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_7eeadbb8-629f-48de-af51-388c94c2327a">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_307f2515-0cee-4ebc-afed-96bd858096d5">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3828" rules="all" xml:id="table_TID_3828">
                    <caption>Discharge Summary, Cath</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_47f2ea38-c388-419d-af7d-a2c106f033b3"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_efea521d-0ad4-4e33-8d5b-b80a66bc0cb5">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9963b01e-ac12-46ba-9310-b46ee235be9f">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_88c1ac28-3aa4-4bdb-b6d8-5d5e0e0aab29">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_214a2c86-ef1b-45db-85c8-7e9dc1c91e62">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a4613a11-e177-4668-bbf5-9ab5f19a3549">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_39e84e64-12e8-407b-aef3-911956c34a52">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_036dc120-164a-4b08-9ae8-1ee96e2ba969">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b0d7038c-1d96-40b2-9377-bb7e125e7ef6">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c6a7ce0-74ab-41bc-8de0-6786ed58323a">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1952a35-6733-45e7-b635-b748ac43a15f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d2930340-a450-4157-881a-da0991162cfa">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd81de0a-9114-406e-9ca5-02501dc06bd4">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e068c6d9-d2ce-4f33-b46b-95f9df59d718">EV <link linkend="DCM_121115" xrefstyle="select: nopage">(121115, DCM, "Discharge Summary")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e1e311ac-5694-4790-b06d-2c053d5b90d0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ac96dca-a9ce-4770-92a8-c56edb4fd65a">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4fa0b2b-d6b1-4c3c-aba8-c56b8ae11de5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e51fd2b-7623-49ee-969c-34c527e1d7b9"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd5b3837-1514-41c7-a5ac-bc113568161e">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb03503d-2e3e-40a7-afdc-af1dbeadd2fe">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4fc81806-d7fd-4014-a47e-e54c0069354b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7cff5184-ee95-4ce6-b440-38c85df3ad3c">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79a66a18-1ec3-484d-88bd-aa7cbee6f45d">EV <link linkend="DCM_122163" xrefstyle="select: nopage">(122163, DCM, "Discharge DateTime")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_19e2db03-34c9-417d-b844-ce13fb47a810">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cecf89fd-2048-464f-af90-2e49d2925be2">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8acd36fd-4919-4ab5-8e57-410f6e30c50d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c740763-f9de-4995-a187-4e6f2cc537b5"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f89cbd9-d508-4df0-81e3-ee211d9e7ea0">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd8ca987-38ed-4710-98a4-56c0d92fcbea">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_badd818d-1361-40f4-bb78-1c865fcdafa2">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_761335ef-2893-42bf-9c28-b77168ee7834">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69ddea9e-c86d-432d-ae94-aea39e042abc">EV <link linkend="DCM_122164" xrefstyle="select: nopage">(122164, DCM, "Coronary Artery Bypass During This Admission")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_977fd926-bcf7-4d42-9639-c84a2529244d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3e59ca2b-f849-4609-abcc-0c6950f5e121">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_95755372-d709-4f18-bcef-d864a90f757f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f7d36d5-f899-45cc-8cf2-699d119efe9a">D<xref linkend="sect_CID_230" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74efe455-383e-44ad-b35f-8d4ceee8b807">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_621426de-c822-4e4f-ae86-2ea07428eef3">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc25534a-8a69-4cf3-ab79-562d04e53d31">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70390057-11e8-4031-af63-c95b65b850d3">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_efe37d3f-cf75-408d-9d84-05cda4b6a01b">EV <link xl:href="http://snomed.info/id/260870009" xl:show="new">(260870009, SCT, "Procedure Priority")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eb193d69-dba9-4796-afc3-c0cb4997d5c4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3dfbd50f-b1a8-4e8c-ad96-61f9440fb9e1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04758414-781b-451b-997d-6eac9d03064b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_349e36dd-0fbc-4cc5-b7a5-f8c8730d359e">B<xref linkend="sect_CID_3414" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c22feb2d-defd-4ca2-a411-8a10512d6f38">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36936d02-06fa-4363-8858-067afb782d76">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da03bd18-2c88-42ff-940c-9c2d2fc23c7c">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_427f138c-c5e9-446c-af21-a4c20fa27cec">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a097d708-cfeb-4a79-8d9d-c3ee74026769">EV <link linkend="DCM_122146" xrefstyle="select: nopage">(122146, DCM, "Procedure DateTime")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6d151f25-1c10-4ab0-bdea-b834bf4436a8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_90cab887-7418-4aac-9202-7b0fe9fedc49">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b05bcb45-6669-4d73-a477-03a9e3611bb1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b72d3510-0eae-4b2b-b250-01966ea0df17"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8fef6f28-d29e-42d9-b04b-03cb91f8c67a">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ddaa01d-410f-46bd-a2bf-9baab31aef58">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dbc55427-49e3-4bdc-ab40-91b3b93613e5">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0470952-fb96-4af0-b096-539c9223893b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_597e29ca-83c5-4e8e-885a-a8ae058f29ce">EV <link linkend="DCM_122166" xrefstyle="select: nopage">(122166, DCM, "Death During This Admission")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_203fafb8-0e7c-4f35-883d-e8350238705a">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_488cddd7-5c74-4d33-a719-3d5ef9cbb267">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5fa2c64c-9f26-46f9-9bf1-773c61601fbd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c163c28-abf7-4520-baf5-48dacadcdab1">D<xref linkend="sect_CID_230" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e3bd49a-af0e-41bf-8ecb-7e1407c1c18c">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3df2c3e-1d04-431a-93d0-4963b610cc21">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4862fa9e-3e45-46b1-be44-127cd2b1c6d6">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3fe05c4a-042e-4427-ade9-393cc2b05ea6">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e4820a1-b2f9-4332-bc09-de93d3d5151b">EV <link linkend="DCM_122165" xrefstyle="select: nopage">(122165, DCM, "DateTime of Death")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3ce08944-525d-4d74-bfdd-56e7c6747fe5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f8a40646-a2b6-487e-b6d1-50fc018fb2e5">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8ca7373-03dd-4aa5-91bb-1f0b586e13c2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d6e1d329-41e1-4f14-a417-e895f298d1f6"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c980735a-2b6f-441f-8738-bb0a1a859b88">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a34dfb0-129f-42e7-8ae7-cdcc9221a338">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_207e1564-6bbc-4727-8119-f9053a315435">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c4f10e7-f178-455f-a8e1-6ca6e01bf90c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_985941b9-2279-400e-ab78-4d00458a9f06">EV (25, NCDR [2.0b], "Primary Cause of Death")</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_226b9fc0-e429-49f1-93a3-b8c18cac9473">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_48a3c4c3-1084-492d-b881-a5e639cbe9dd">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c0e5a2e-8450-4bbf-9b9a-a07b4b30fb03"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_839f8915-e923-4a59-8e35-7ebaf1d43bdf">D<xref linkend="sect_CID_3733" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7012e22c-c629-4214-84be-93098d1f2c21">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_888091c5-d93d-459b-9b6a-aa70799ce49d">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08818809-f43f-4f52-a0d2-19763b07c666">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7848f8a4-a66d-454d-be31-8326443e0414">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca48f6fc-34b1-4dce-81dc-77d897e38961">EV <link linkend="DCM_122167" xrefstyle="select: nopage">(122167, DCM, "Death During Catheterization")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_65dc6619-80b9-41f2-8a40-a57c03099e10">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_42397795-defc-489d-9776-76fd69b3ca3c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b326dd77-78a4-4d3c-83d2-84ccda7d6991"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1070957d-d520-4483-91d0-8bf81b6b925e">D<xref linkend="sect_CID_230" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2114c9c8-768d-467f-bdc2-54d4e4b51ef8">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e66909a-5e58-4e56-b99c-b9f5aced9423">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fefb437e-a25b-4514-a3d4-c7343296d465">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bc99f671-5b81-4222-a154-6080469dc6d8">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_349a246a-9267-47a4-96fc-3558f3a1edf4">EV <link xl:href="http://loinc.org/55112-7/" xl:show="new">(55112-7, LN, "Summary")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_926b82f5-87f7-4889-aa42-62d577f017f4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6170bad3-fcbf-4bb2-94b6-f8a909061258">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f846585-4a16-449d-bb53-4a1b8a5b5786"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7833514a-fd66-4608-89cb-64c0ffec0e64"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3829" status="3" xml:id="sect_TID_3829">
                <title>Problem Properties</title>
                <table frame="box" label="TID 3829" rules="all" xml:id="table_TID_3829_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0b96838c-48e7-4815-be63-3468f92568a5">Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_226db648-9f86-4154-bd09-6898a57e10bb">Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1120786-eee5-4ba3-ab86-95b976357008">$Problem</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10e98a49-1a98-426a-a4e0-dc9843eb0a35">Coded Value or Context Group for problem</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7a2e7fb7-95b5-45bf-b8b8-50d002c7711c">$ModType</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1469327c-6a16-4bbc-9a83-a0ceecabf3d5">Modifier Name for Concept Name of problem</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b382909-298f-4f84-96d6-525bf9e8ff46">$ModValue</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8412ffe7-3028-440c-9a2b-1224e66807d7">Modifier Value for Concept Name of problem</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63c7dadb-0745-4c51-a5ff-f3cd04bbfe92">$Therapy</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c612dc7-bf24-4ead-a05b-288dc2aa4d07">Coded Value or Context Group for therapy received for problem</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2627b0b1-94e6-4498-90b1-a4c8c09c1498">$Stage</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_18c5742b-51f9-4b19-bc95-b2fa3a84b857">Coded Value or Context Group for problem or disease stage</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_88e8eb97-468e-4610-8360-98ae9ac3ba2a">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_626a9536-eed0-40fe-abbe-032c3c36c5fb">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_f18293a2-d63e-49a8-8761-129b732dbfec">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3829" rules="all" xml:id="table_TID_3829">
                    <caption>Problem Properties</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2e53a0a4-49b9-4fbd-914b-2550122bb2e3"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8a8c6ab7-2a8d-4062-98a8-ac71e0f6a6f5">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_53231efd-53b6-4400-a514-0b81d00d4e78">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e5c2c0b1-4c7e-4e88-8abc-3a50e739d76e">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a1b2e0a4-1ef9-468c-aac1-2a8693b83c57">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc77d4d3-d236-4105-ac5a-2930c68b0ac0">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ecad2814-4656-433f-99e1-6188be488406">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4e810099-93f8-46ed-a67c-02ff93668011">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8028f42c-d8b8-4ef9-8bd2-67b462ac76b6">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88a92b64-d6ad-425f-bb45-501e72895b51">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_90cf8bc8-4bd2-4095-bc23-b319a6af5e15"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_14d11ac0-a4bb-441a-bd3d-566e3a47d613"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bab6c2e4-06bf-48bd-8223-635f0dd54ff8">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2a549845-c27b-42ba-a1d1-ad1e47cbfb4d">EV <link linkend="DCM_121430" xrefstyle="select: nopage">(121430, DCM, "Concern")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_289306ce-26b1-42fa-91de-21f49e6162e1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_31ebe61a-50e3-49b5-bdd7-5c2ca1063682">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc82c6c2-ab3f-4f27-ba76-599d18d3aefd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc03f297-16a2-4ce6-84cd-cb81c6f0b4a6"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82dfa6eb-e65e-4627-82eb-e116d01c1d5c">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6e36ccd-ca9f-403a-bd9e-317afd4af5ba">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_536a55be-c066-4cc2-aac7-1533f5bd6582">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_afac8040-ee21-4980-af05-6f36dd7b0be5">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a928566-ea05-4084-86b4-acf41d079296">DT <link linkend="DCM_121431" xrefstyle="select: nopage">(121431, DCM, "DateTime Concern Noted")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2ae58c7e-13a0-4bd6-b46a-419e63d8bb91">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f643c6ea-7637-460d-ac1d-95017693fc77">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83fc4672-da3b-4b5d-acff-07113d2f4f44"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6bac1046-5cf7-4a50-a6df-6e542aa73655"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67157342-17f5-4483-9a5b-e40dea7ea431">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f776272-786a-4b84-9f03-98efdefbdd32">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_241ecbaf-1252-4ed9-92ee-af04be81f309">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_28b635f2-468f-4969-a28d-8f730333cc58">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6dbf8b7f-d79c-45f0-b46d-d217056135bf">DT <link linkend="DCM_121432" xrefstyle="select: nopage">(121432, DCM, "DateTime Concern Resolved")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2e5a54d6-33d9-45fc-a0ac-0b84ee134043">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_57abca45-8d8c-46a6-a609-de646fd83822">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aec39495-02b3-4771-85c1-4c1a7111bee1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e122c3a8-ee77-4701-9411-fc3e046c5c8a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6692ac94-b6b7-4d11-ae66-fbe313fa4e54">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_996ce8b7-87b1-4ca8-a4dc-d560d56711aa">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6bdb704c-cdee-41b8-aa8b-35d6283352aa">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a01033e7-0b6f-4bca-8a28-93e11f633a4c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc43900c-4bcd-475f-b85d-10dce42f991a">D<xref linkend="sect_CID_3769" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0a2365ae-be79-452b-992c-ede09fb1d80d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_99965523-d46c-45a1-ac05-17ba6b355df5">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e906858-d2b6-49a3-9bc9-a89acda34024"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0441a44-a53c-4a40-a4f6-71ef44a09485">$Problem</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82571c43-5be4-46b8-bcaa-bbad2cc11047">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72838e86-a5da-4c66-a42e-7ec69721063f">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ece464e-e8ed-4d97-9d65-9fb62bacaef2">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72618d1c-8a77-4022-a766-638dee3a2e68">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_407989ff-0723-46ea-8226-80c69376fa8a">$ModType</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1776eeaa-241c-455b-9575-e4ecf4d21fa1">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2887f3f1-a094-4098-86ef-267419795b25">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31d7dce6-7f2c-4671-9b2f-7a95dce1515c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_451adc7b-aae4-4e22-b28e-2bd28c840fe9">$ModValue</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2776ab9d-b289-49c8-b54b-1566bc6a7ce2">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f81c5a3-9e9f-43e8-9f43-6cf6a20dc808">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c60c0302-44b4-4534-859d-3c46fe4ef561">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a6056ed-dd27-4c76-8c7c-86869358652e">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0188292-b4ba-419a-9205-b7e8b95b4d2d">DT <link linkend="DCM_111526" xrefstyle="select: nopage">(111526, DCM, "DateTime Started")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f0d3b66d-c635-4c27-aa30-d185ab852ea8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c14ef32d-d43e-4c86-ae73-6e84d44b582f">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_78f6e2f5-d506-4de7-a603-5f31d410e669"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4309b10-d9e2-4d9f-9248-fdf958d7130c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ad647a7-9442-4390-af85-88aaa6aa935f">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ce5ff08-f7ba-496a-9624-e7907f9ccbab">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b2a0628-7fae-4a1a-a87b-6823f8abf987">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e29fe9c5-e208-4d3c-8b90-b27cad7f7198">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46b72976-aa85-4181-9597-1a94de9f031e">DT <link linkend="DCM_121433" xrefstyle="select: nopage">(121433, DCM, "DateTime Problem Resolved")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_779dd828-dc4a-48f2-84fb-d79b2963cf02">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e5c21f72-bfda-4703-9068-d252af49b530">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bcd36609-8bf1-44d6-b9ec-aeebd42d2a6f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81ba1a20-1fc8-40f5-bb81-0a21c2dc28a4"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22679803-7253-46c8-8a27-b9ec14bb8b91">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eceabc67-4dfe-42e5-b2c8-2db03cebefb5">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_677bb69c-1e3a-42a0-a54c-103d33ae4167">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43ab35d6-c3ce-463b-b721-8d64833fa17c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd9cb94c-61de-4017-8363-730a792186a5">DT <link xl:href="http://loinc.org/33999-4/" xl:show="new">(33999-4, LN, "Status")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_43874c47-670d-4b3b-9bfd-347972cf70c2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5e39a2cb-b3ab-4b27-9a10-e7529d6a7b33">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3b1e74d-a4d3-408e-8501-cb8ffe6bf844"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f7e377a6-1722-4ce8-8c3b-493f0ddfaabd">D<xref linkend="sect_CID_3770" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6aa3fceb-9404-45f7-afc7-3aad9ef077a3">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25c5f822-7b82-4e86-b972-650a957162cb">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7604ae7-05d6-477e-a632-7b177ff3abd6">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b113539-c27f-4ba3-b14a-53ff7b624754">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eae0a56c-589e-4196-801e-c36f5444f9c8">DT <link xl:href="http://snomed.info/id/246112005" xl:show="new">(246112005, SCT, "Severity")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_76cc4edd-cf60-4389-b012-7f15b872abd2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_83ed4cb0-4947-40ae-810b-6e7ccb1bc676">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae070a27-cddd-4fb1-a804-d6882beba934"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f7f0345-924c-41a8-82cc-89e70e824d05">D<xref linkend="sect_CID_3716" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b612a512-4a99-4a05-b958-8f5f109d5f70">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70fcf50e-9534-439b-b9d2-fe3d7e944657">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75b73f9c-649b-4d4e-a7a6-81bee01e452b">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_957e790e-501f-4af1-9d0b-243756824b97">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b77d00c2-a456-41c9-9fe2-9540f70ff2bb">DT <link xl:href="http://snomed.info/id/258214002" xl:show="new">(258214002, SCT, "Stage")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d0500e98-0440-4adc-a03b-effd300fb5a6">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_02e18732-8e0c-4add-b79c-3790ccd8cacc">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7bb578d2-b188-4887-bfe5-34101c1f0cd9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_77649c74-6170-4aff-8637-5bb5b0ab48cf">$Stage</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc267f8b-3bde-4349-95d3-f99a36570498">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_face9621-3d9c-4294-8cfb-2d9585712c9e">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dfa74395-806b-4c3a-9280-02815c3933dd">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ed295e9-ac40-417d-a7db-9f8491b6a828">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4875559b-589d-440b-a294-f9fdb052317a">DT <link xl:href="http://loinc.org/11323-3/" xl:show="new">(11323-3, LN, "Health status")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ccaeb45-1afd-440e-8ce3-bbc54a796e74">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9b325a00-dde6-452b-bdf3-ba91b839c6a0">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0c17e1c1-258f-4c88-9a1b-1ee59fe2f78d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d982c87a-9d7c-4447-8748-fc591674ffd8">D<xref linkend="sect_CID_3772" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d59a6533-e591-4a51-95be-221614eb454d">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84506190-68a9-4e6b-ac9b-d0ec664b927f">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e18b70b4-2ecc-43ed-9777-1c17d3395a87">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_322c8126-c530-46a7-8b0e-598a31c81e12">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec65e823-68ad-418d-9a45-effe92eeea94">EV <link xl:href="http://snomed.info/id/277132007" xl:show="new">(277132007, SCT, "Therapy")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_80ffb78d-4096-4a1a-b6a4-f75f60379b69">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a6e12e5d-af93-4c91-83f1-d4f13084b825">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ad61683-6def-4f83-b9e5-ba5e7e2c4b72"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_430f74d1-a8f9-4930-8e61-4503ea806f9c">$Therapy</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b6ab679-d303-4067-bd63-986e336ec3ba">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b05a558-d912-4002-bde5-e333b898055d">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5224735c-a433-4892-af77-679efc8faa10">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a1d2e5ae-09f5-404b-b3f1-9e9ab29286df">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6983bcb9-e3b0-4bb7-8bb0-2073c0830463">DT <link xl:href="http://loinc.org/33999-4/" xl:show="new">(33999-4, LN, "Status")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_804c685e-0446-4636-8f4d-868f2aa23903">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0bc9d72c-35ed-4f89-855d-b5383d951bbc">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b93fdd88-8144-4a94-b2ed-f6f2227193c9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d55adbe-e75a-4efe-b7e9-d96de4202c83">D<xref linkend="sect_CID_3773" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74cbef38-22ee-4cf1-914f-a7c0601418d3">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1f9aad36-98bc-49bc-b441-d55f278ff614">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5befc13a-9596-4693-86d3-5afdd4006d18">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_28c968e6-4b39-4f31-9270-00a6bfc8a268">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_71ae8a89-3f7f-4df9-b401-060808c59c9a">EV <link linkend="DCM_121106" xrefstyle="select: nopage">(121106, DCM, "Comment")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e252a835-acb8-4983-9c64-6af0dd588baf">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d9ea75f5-50fc-455c-8c4e-776abde68e4e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3dc1da3e-d41d-471d-9e56-914c935db990"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_caba04c7-7c45-46fe-b62b-4f4bb724b772"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 3830" status="3" xml:id="sect_TID_3830">
                <title>Procedure Properties</title>
                <table frame="box" label="TID 3830" rules="all" xml:id="table_TID_3830_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3946f6e9-2924-4803-aa2c-f5f30dc093e2">Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b527c1a3-bcda-4489-ac17-3b050ddad82c">Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6728a6f9-c05a-41d2-9f26-b05103239d1e">$ProcType</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8894020a-4e0c-44cd-8ac5-087e7f5499c1">Coded Value for class of procedure</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2ca8749-4f84-4116-839c-6191e9a7c34e">$Procedure</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_125defd9-1e3d-4c69-a861-c0a390aa64cf">Coded Value or Context Group for procedure</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_568c9c01-9563-42ce-a319-ea1d934e0c3e">$ModType</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4338bcd6-aa6f-4034-9bb9-494c10d98e40">Modifier Name for Concept Name of procedure</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_49283996-cd9d-4d09-9da8-f7ca54cd954e">$ModValue</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a785efa-0127-49af-815f-ef03c16ac4ce">Modifier Value for Concept Name of procedure</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f49b4da-4e1b-48f3-a58b-27afa3b9f7b4">$ProcedureResult</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_346c8f67-16e2-4f92-96a0-b8fa927bebb3">Coded result of the procedure</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_fb0830af-aa72-4ba3-a72a-61a01fe41805">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_834eebec-0353-4a3c-b6ed-b422b06696d4">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_e0050233-68da-478b-a9a9-b6c2436493aa">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 3830" rules="all" xml:id="table_TID_3830">
                    <caption>Procedure Properties</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fba76692-22a4-427f-a093-98d595d5a012"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a74dbb57-b04d-4337-add0-8d3770c495f3">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_33e5457f-5ad6-41c2-b81f-616b9c691caa">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ce2d89df-f729-49c5-927b-bf085a5d1e2e">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_603630ca-f5c3-4fe8-9e60-298fb077d83a">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fc7cb7c8-e6ab-40d1-8969-87ca002e7ce7">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_71d62999-0d05-4969-bd68-fc7c6ad7c359">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_15d02e1e-1a48-449b-953d-2e5899d5f8fc">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f084a0a1-4f49-41c2-9b3d-583994547074">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_902a2b05-e1b6-4755-931c-bd57906b74e1">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_712aebec-46a3-4de0-a7ec-48892f2ced36"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_33c9afdd-b0f3-4339-83d7-29d4e4abb6f2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f4dceb4-032f-4d18-9e40-de2bd8995d9b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7f56da0-f319-4447-858c-4ac49c5a4f99">$ProcType</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c0c4777c-fb99-4ae9-882e-e4d4250bc887">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2a9a33e0-3692-48e5-8a86-6ce4f54e5250">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cef36bd0-a217-41ae-8b79-12388f529443"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7bb80432-8c6c-42b2-8cec-5e580fa23cca">$Procedure</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b8980e8-edcd-4f7f-a371-4d29ac5447be">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b31a32a5-a751-4c4f-bcc6-4e5e18761f05">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d52467a7-1340-4bf4-b3df-0a460bb6dc66">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46e24485-b11b-40fd-afdd-67797ce2131e">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fed51218-72c1-4666-abca-6a49efd24c70">$ModType</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_82d6dc7b-a8fd-42cd-be43-aadc1620249c">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ccda81cb-f7bf-4a5a-86f4-a442b7fff82d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88d93e13-a460-4c2f-aee8-9c1d943868a6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3e8b3f6-868f-4b1b-b251-fab3500be6ad">$ModValue</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91e1d277-a46c-46f2-bb97-5fd471098ce6">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62540f6d-4cde-4933-a84a-b9c954240772">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_881b067c-5fec-49a8-8ccb-c893d12062b4">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c9c2e57-1e29-4527-a340-7233111dbfd6">DATETIME</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02720a35-97ac-4d47-8582-f9dbe2a2259e">DT <link linkend="DCM_122146" xrefstyle="select: nopage">(122146, DCM, "Procedure DateTime")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ece44434-e7a7-429b-a06a-5dd525a7a5c3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_949238b8-27c2-4730-add8-fe4c99c82404">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d9af196-e494-485e-a24c-107a174fc94b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24dd9d8f-a75e-47ff-bca8-cd44676161bd"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e5a792f-36b7-44f6-beb6-35e2d3fcd18c">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61a3d598-36f2-4694-a20a-020a6dcbba61">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0d07e7d-a955-4734-8236-3cd167a26243">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70caac6a-9b33-498b-b07f-f98dc3146250">COMPOSITE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5f6bd82-e4fc-4a94-84c1-90e0762c4a6a">EV <link xl:href="http://snomed.info/id/371524004" xl:show="new">(371524004, SCT, "Clinical Report")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f1fe0299-537c-4290-9ec5-f2660f7457ad">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e9319eaf-9983-467f-8c1e-f45b1101d81b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_818be0c0-b525-48a6-ba2a-9d1eba112bb5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0851cf35-2351-472c-8d8f-925b4a7b06d1"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ffc2783-44fe-4f06-ac20-97a7a722f9d6">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59b885db-402c-4ae6-beac-d77290bb33bb">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e56f04ae-de79-43cb-85c3-d4f4a4ba0700">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_459415ad-7c22-4d8e-9199-199af6e41ddb">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_32c85a5d-8c3d-4056-9d00-2dcaf7d5d507">EV <link linkend="DCM_121144" xrefstyle="select: nopage">(121144, DCM, "Document Title")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c45675c1-d007-4c9c-8940-d67c092313b1">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b195241b-c951-4c92-92ef-75c9e1a3b072">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8fe2a14b-a9bd-4e6b-810d-848554b8d23c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9cb19781-c902-494a-8769-00e4d0b1118b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c89292e-9111-4dbc-aad2-910fe1cad13c">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c0d8069-e3b7-4c2d-8df8-4eb9e66229e9">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b715ebc3-a565-446b-9780-25581224afd1">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea26f263-e3e9-4f66-af50-1ef43cc29ef2">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef73f078-9134-48cb-a4ff-77710cc0c644">EV <link xl:href="http://snomed.info/id/371524004" xl:show="new">(371524004, SCT, "Clinical Report")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cb665218-6220-4d43-bb8f-701cbaaebe42">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_002ace35-6cc3-4f82-a4e8-5bcb9cde88cf">U</para>