<?xml version="1.0" encoding="utf-8" standalone="no"?>
<book xmlns="http://docbook.org/ns/docbook" xmlns:xhtml="http://www.w3.org/1999/xhtml" xmlns:xl="http://www.w3.org/1999/xlink" label="PS3.15" version="5.0" xml:id="PS3.15">
  <title>PS3.15</title>
  <subtitle>DICOM PS3.15 2026d - Security and System Management Profiles</subtitle>
  <info>
    <author>
      <orgname>DICOM Standards Committee</orgname>
    </author>
    <copyright>
      <year>2026</year>
      <holder>NEMA</holder>
    </copyright>
      <legalnotice>
          <para xml:id="para_78f13c74-b629-43d9-80ee-cf8f030e913c">A DICOM® publication</para>
      </legalnotice>
  </info>
  <chapter label="" status="1" xml:id="chapter_Notice">
    <title>Notice and Disclaimer</title>
    <para xml:id="para_aed8bf04-6bcb-4104-a5f7-653562b6f27f">The information in this publication was considered technically sound by the consensus of
      persons engaged in the development and approval of the document at the time it was developed.
      Consensus does not necessarily mean that there is unanimous agreement among every person
      participating in the development of this document.</para>
    <para xml:id="para_6f8e8143-7078-4877-bf66-d858b67e91b0">NEMA standards and guideline publications, of which the document contained herein is one,
      are developed through a voluntary consensus standards development process. This process brings
      together volunteers and/or seeks out the views of persons who have an interest in the topic
      covered by this publication. While NEMA administers the process and establishes rules to
      promote fairness in the development of consensus, it does not write the document and it does
      not independently test, evaluate, or verify the accuracy or completeness of any information or
      the soundness of any judgments contained in its standards and guideline publications.</para>
    <para xml:id="para_80d3d2b8-db06-4f9a-be3e-5deb7726b5ca">NEMA disclaims liability for any personal injury, property, or other damages of any nature
      whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly
      resulting from the publication, use of, application, or reliance on this document. NEMA
      disclaims and makes no guaranty or warranty, expressed or implied, as to the accuracy or
      completeness of any information published herein, and disclaims and makes no warranty that the
      information in this document will fulfill any of your particular purposes or needs. NEMA does
      not undertake to guarantee the performance of any individual manufacturer or seller's products
      or services by virtue of this standard or guide.</para>
    <para xml:id="para_272f3acf-ce6f-4444-ab4f-2219866402f8">In publishing and making this document available, NEMA is not undertaking to render
      professional or other services for or on behalf of any person or entity, nor is NEMA
      undertaking to perform any duty owed by any person or entity to someone else. Anyone using
      this document should rely on his or her own independent judgment or, as appropriate, seek the
      advice of a competent professional in determining the exercise of reasonable care in any given
      circumstances. Information and other standards on the topic covered by this publication may be
      available from other sources, which the user may wish to consult for additional views or
      information not covered by this publication.</para>
    <para xml:id="para_6700b06f-e7a1-45e6-a94a-1d8fe616dfdb">NEMA has no power, nor does it undertake to police or enforce compliance with the contents
      of this document. NEMA does not certify, test, or inspect products, designs, or installations
      for safety or health purposes. Any certification or other statement of compliance with any
      health or safety-related information in this document shall not be attributable to NEMA and is
      solely the responsibility of the certifier or maker of the statement.</para>
  </chapter>
  <chapter label="" status="1" xml:id="chapter_Foreword">
    <title>Foreword</title>
    <para xml:id="para_787a0f0f-1ad1-4e1e-bd29-39c19a428361">This DICOM Standard was developed according to the procedures of the DICOM Standards Committee.</para>
    <para xml:id="para_7020e657-a0d8-4ced-9e73-8ac40006290b">The DICOM Standard is structured as a multi-part document using the guidelines established in <xref linkend="biblio_ISODirectives2"/>.</para>
    <para xml:id="para_f6076693-75ac-494a-a73f-30aeea24887d">DICOM® is the registered trademark of the National Electrical Manufacturers Association for its standards publications relating to digital communications of medical information, all rights reserved.</para>
    <para xml:id="para_279e1a9a-b87a-4ef9-b7d4-5b780de8b1d8">HL7® and CDA® are the registered trademarks of Health Level Seven International, all rights reserved.</para>
    <para xml:id="para_ba30052f-5c1d-4bb1-b29a-5e65913ce9d1">SNOMED®, SNOMED Clinical Terms®, SNOMED CT® are the registered trademarks of the International Health Terminology Standards Development <foreignphrase xml:lang="en-GB">Organisation</foreignphrase> (IHTSDO), all rights reserved.</para>
    <para xml:id="para_1bf2021f-7dbe-494a-aa51-57850fd2cb74">LOINC® is the registered trademark of Regenstrief Institute, Inc, all rights reserved.</para>
  </chapter>
  <chapter label="1" status="1" xml:id="chapter_1">
    <title>Scope and Field of Application</title>
  
  <para xml:id="para_eeedcbbb-4ac7-457b-8b68-52527a88532e">This Part of the DICOM Standard specifies Security and System Management Profiles to which implementations may claim conformance. Security and System Management Profiles are defined by referencing externally developed standard protocols, such as TLS, ISCL, DHCP, and LDAP, with attention to their use in a system that uses DICOM Standard protocols for information interchange.</para>
  <section label="1.1" status="2" xml:id="sect_1.1">
    <title>Security Policies and Mechanisms</title>
  
  <para xml:id="para_3d0d52bf-3881-4b19-8002-acdea3ca5614">The DICOM Standard does not address issues of security policies, though clearly adherence to appropriate security policies is necessary for any level of security. The Standard only provides mechanisms that could be used to implement security policies with regard to the interchange of DICOM objects between Application Entities. For example, a security policy may dictate some level of access control. This Standard does not consider access control policies, but does provide the technological means for the Application Entities involved to exchange sufficient information to implement access control policies.</para>
  <para xml:id="para_f74f1a23-9450-49d6-a678-b1771ec2a1a5">This Standard assumes that the Application Entities involved in a DICOM interchange are implementing appropriate security policies, including, but not limited to access control, audit trails, physical protection, maintaining the confidentiality and integrity of data, and mechanisms to identify users and their rights to access data. Essentially, each Application Entity must insure that their own local environment is secure before even attempting secure communications with other Application Entities.</para>
  <para xml:id="para_135157c5-c250-4643-a837-04680b6119f1">When Application Entities agree to interchange information via DICOM through association negotiation, they are essentially agreeing to some level of trust in the other Application Entities. Primarily Application Entities trust that their communication partners will maintain the confidentiality and integrity of data under their control. Of course that level of trust may be dictated by local security and access control policies.</para>
  <para xml:id="para_d03aefa5-f2f9-4e1e-8e58-501b06cb71f0">Application Entities may not trust the communications channel by which they communicate with other Application Entities. Thus, this Standard provides mechanisms for Application Entities to securely authenticate each other, to detect any tampering with or alteration of messages exchanged, and to protect the confidentiality of those messages while traversing the communications channel. Application Entities can optionally utilize any of these mechanisms, depending on the level of trust they place in the communications channel.</para>
  <para xml:id="para_e370bcb0-33d9-46e9-841f-fb95f1b53e48">This Standard assumes that Application Entities can securely identify local users of the Application Entity, and that user's roles or licenses. Note that users may be persons, or may be abstract entities, such as organizations or pieces of equipment. When Application Entities agree to an exchange of information via DICOM, they may also exchange information about the users of the Application Entity via the Certificates exchanged in setting up the secure channel. The Application Entity may then consider the information contained in the Certificates about the users, whether local or remote, in implementing an access control policy or in generating audit trails.</para>
  <para xml:id="para_6057d30b-d766-4b53-b4c3-95bf6b7d3f08">This Standard also assumes that Application Entities have means to determine whether or not the "owners" (e.g., patient, institution) of information have authorized particular users, or classes of users to access information. This Standard further assumes that such authorization might be considered in the access control provided by the Application Entity. At this time, this Standard does not consider how such authorization might be communicated between Application Entities, though that may be a topic for consideration at some future date.</para>
  <para xml:id="para_fe72730b-3a37-4c44-af39-c866cffed4ec">This Standard also assumes that an Application Entity using TLS has secure access to or can securely obtain <xref linkend="biblio_ITU-T_X.509"/> key Certificates for the users of the application entity. In addition, this Standard assumes that an Application Entity has the means to validate an <xref linkend="biblio_ITU-T_X.509"/> certificate that it receives. The validation mechanism may use locally administered authorities, publicly available authorities, or some trusted third party.</para>
  <para xml:id="para_3dcc17fb-6101-4145-aa02-329403918eba">This Standard assumes that an Application Entity using ISCL has access to an appropriate key management and distribution system (e.g., smartcards). The nature and use of such a key management and distribution system is beyond the scope of DICOM, though it may be part of the security policies used at particular sites.</para>
  </section>
<section label="1.2" status="2" xml:id="sect_1.2">
    <title>System Management Profiles</title>
  
  <para xml:id="para_8b2e5321-fae9-4976-92ac-c0b6004b15ae">The System Management Profiles specified in this Part are designed to support automation of the configuration management processes necessary to operate a system that uses DICOM Standard protocols for information interchange.</para>
  <para xml:id="para_c815fac6-f74c-48c6-8287-69bbdcc4c29a">This Part assumes that the Application Entities may operate in a variety of network environments of differing complexity. These environments may range from a few units operating on an isolated network, to a department-level network with some limited centralized network support services, to an enterprise-level network with significant network management services. Note that the System Management Profiles are generally addressed to the implementation, not to Application Entities. The same Profiles need to be supported by the different applications on the network.</para>
  </section>
</chapter>
<chapter label="2" status="1" xml:id="chapter_2">
    <title>Normative References</title>
  <para xml:id="para_895753cc-c1f5-4189-9900-0d1305e63828">The following standards contain provisions that, through reference in this text, constitute provisions of this Standard. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this Standard are encouraged to investigate the possibilities of applying the most recent editions of the standards indicated below.</para>
    <note>
        <para xml:id="para_7a3fb8ed-7510-486c-b790-d36c06e0b0b9">Normative RFCs are frequently updated by issuance of subsequent RFCs. The original older RFC is not modified to include references to the newer RFC.</para>
    </note>   
    <bibliography>
        <biblioentry xml:id="biblio_ISODirectives2">
            <abbrev>ISO/IEC Directives, Part 2</abbrev>
            <author>
                <orgname>ISO/IEC</orgname>
            </author>
            <date>2021</date>
            <edition>9.0</edition>
            <title>Rules for the structure and drafting of International Standards</title>
            <bibliosource>
                <link xl:href="http://www.iso.org/sites/directives/current/part2/index.xhtml"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_ISO7498-1">
            <abbrev>ISO 7498-1</abbrev>
            <author>
                <orgname>ISO</orgname>
            </author>
            <date>1994</date>
            <title>Information Processing Systems - Open Systems Interconnection - Basic Reference Model</title>
        </biblioentry>
        <biblioentry xml:id="biblio_ISO7498-2">
            <abbrev>ISO 7498-2</abbrev>
            <author>
                <orgname>ISO</orgname>
            </author>
            <date>1989</date>
            <title>Information processing systems - Open Systems Interconnection - Basic reference Model - Part 2: Security Architecture</title>
        </biblioentry>
        <biblioentry xml:id="biblio_ISO8509">
            <abbrev>ISO/TR 8509</abbrev>
            <author>
                <orgname>ISO</orgname>
            </author>
            <title>Information Processing Systems - Open Systems Interconnection - Service Conventions</title>
            <releaseinfo>
                <remark>ISO/TR 8509 has been withdrawn. See ISO/IEC 2382-26:1993 Information technology - Vocabulary - Part 26: Open systems interconnection</remark>
            </releaseinfo>
        </biblioentry>
        <biblioentry xml:id="biblio_ISO8649">
            <abbrev>ISO 8649</abbrev>
            <author>
                <orgname>ISO</orgname>
            </author>
            <date>1988</date>
            <title>Information processing systems - Open Systems Interconnection - Service definition for the Association Control Service Element (ACSE)</title>
        </biblioentry>
        <biblioentry xml:id="biblio_ISOIEC10118-3">
            <abbrev>ISO/IEC 10118-3</abbrev>
            <author>
                <orgname>ISO</orgname>
            </author>
            <date>2004</date>
            <title>Information technology - Security techniques - Hash-functions - Part 3: Dedicated hash-functions (RIPEMD-160 reference)</title>
            <releaseinfo>
                <remark xml:id="para_f641993e-69a8-40dd-8e94-81b442a281e9">The draft RIPEMD-160 specification and sample code are also available at <link xl:href="http://homes.esat.kuleuven.be/~bosselae/ripemd160.html"/>
                </remark>
            </releaseinfo>
        </biblioentry>
        <biblioentry xml:id="biblio_ECMA235">
            <abbrev>ECMA 235</abbrev>
            <author>
                <orgname>ECMA</orgname>
            </author>
            <date>March 1996</date>
            <title>The ECMA GSS-API Mechanism</title>
            <bibliosource>
                <link xl:href="http://www.ecma-international.org/publications/standards/Ecma-235.htm"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_ANSIX9.52">
            <abbrev>ANSI X9.52</abbrev>
            <author>
                <orgname>ANSI</orgname>
            </author>
            <date>1998</date>
            <title>Triple Data Encryption Algorithm Modes of Operation</title>
        </biblioentry>
        <biblioentry xml:id="biblio_DNSSD">
            <abbrev>DNS-SD</abbrev>
            <author>
                <personname>Cheshire S.</personname>
            </author>
            <title>DNS Self-Discovery</title>
            <bibliosource>
                <link xl:href="http://www.dns-sd.org/"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_FIPS_180-1">
            <abbrev>FIPS 180-1</abbrev>
            <author>
                <orgname>National Institute of Standards and Technology</orgname>
            </author>
            <date>17 April 1995</date>
            <title>SHA-1: Secure Hash Standard</title>
        </biblioentry>
        <biblioentry xml:id="biblio_FIPS_180-2">
            <abbrev>FIPS 180-2</abbrev>
            <author>
                <orgname>National Institute of Standards and Technology</orgname>
            </author>
            <date>1 August 2002</date>
            <title>SHA-2: Secure Hash Standard</title>
        </biblioentry>
        <biblioentry xml:id="biblio_ITU-T_X.509">
            <abbrev>ITU-T X.509</abbrev>
            <author>
                <orgname>ITU</orgname>
            </author>
            <title>Information technology - Open Systems Interconnection - The directory: Public-key and attribute certificate frameworks</title>
            <bibliosource>
                <link xl:href="http://www.itu.int/rec/T-REC-X.509"/>
            </bibliosource>
            <releaseinfo>ITU-T Recommendation X.509 is similar to ISO/IEC 9594-8 1990. However, the ITU-T recommendation is the more familiar form, and was revised in 1993 and 2000, with two sets of corrections in 2001. ITU-T was formerly known as CCITT.</releaseinfo>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_1035">
            <abbrev>RFC 1035</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <title>Domain Name System (DNS)</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc1035"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_2030">
            <abbrev>RFC 2030</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <title>Simple Network Time Protocol (SNTP) Version 4</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc2030"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_2131">
            <abbrev>RFC 2131</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <title>Dynamic Host Configuration Protocol</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc2131"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_2132">
            <abbrev>RFC 2132</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <title>Dynamic Host Configuration Protocol Options</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc2132"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_2136">
            <abbrev>RFC 2136</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <title>Dynamic Updates in the Domain Name System (DNS UPDATE)</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc2136"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_2181">
            <abbrev>RFC 2181</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <title>Clarifications to the DNS Specification</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc2181"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_2219">
            <abbrev>RFC 2219</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <title>Use of DNS Aliases for Network Services</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc2219"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_2246">
            <abbrev>RFC 2246</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <title>Transport Layer Security (TLS) 1.0 Internet Engineering Task Force</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc2246"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_2251">
            <abbrev>RFC 2251</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <title>Lightweight Directory Access Protocol (v3)</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc2251"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_2313">
            <abbrev>RFC 2313</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <date>March 1998</date>
            <title>PKCS #1: RSA Encryption, Version 1.5</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc2313"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_2437">
            <abbrev>RFC 2437</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <date>October 1998</date>
            <title>PKCS #1: RSA Cryptography Specifications - Version 2.0</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc2437"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_2563">
            <abbrev>RFC 2563</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <title>DHCP Option to Disable Stateless Auto-Configuration in IPv4 Clients</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc2563"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_2782">
            <abbrev>RFC 2782</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <title>A DNS RR for specifying the location of services (DNS SRV)</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc2782"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_2827">
            <abbrev>RFC 2827</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <title>Network Ingress Filtering: Defeating Denial of Service Attacks which employ IP Source Address Spoofing</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc2827"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_2849">
            <abbrev>RFC 2849</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <title>The LDAP Data Interchange Format (LDIF)</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc2849"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_2898">
            <abbrev>RFC 2898</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <date>September 2000</date>
            <title>PKCS #5: Password-Based Cryptography Specification Version 2.0</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc2898"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_3161">
            <abbrev>RFC 3161</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <date>March 2000</date>
            <title>Internet X.509 Public Key Infrastructure - Time-Stamp Protocol (TSP)</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc3161"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_3164">
            <abbrev>RFC 3164</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <date>August 2001</date>
            <title>The BSD syslog Protocol</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc3164"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_3211">
            <abbrev>RFC 3211</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <date>December 2001</date>
            <title>Password-based Encryption for CMS</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc3211"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_3268">
            <abbrev>RFC 3268</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <date>June 2002</date>
            <title>Advanced Encryption Standard (AES) Ciphersuites for Transport Layer Security (TLS)</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc3268"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_3447">
            <abbrev>RFC 3447</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <date>February 2003</date>
            <title>PKCS #1 RSA Cryptography Specifications Version 2.1</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc3447"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_3370">
            <abbrev>RFC 3370</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <date>August 2002</date>
            <title>Cryptographic Message Syntax (CMS) Algorithms</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc3370"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_3565">
            <abbrev>RFC 3565</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <date>July 2003</date>
            <title>Use of the Advanced Encryption Standard (AES) Encryption Algorithm in Cryptographic Message Syntax (CMS)</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc3565"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_3851">
            <abbrev>RFC 3851</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <title>Secure/Multipurpose Internet Mail Extensions (S/MIME) Version 3.1 Message Specification</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc3851"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_3853">
            <abbrev>RFC 3853</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <title>S/MIME Advanced Encryption Standard (AES) Requirement for the Session Initiation Protocol (SIP)</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc3853"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_3881">
            <abbrev>RFC 3881</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <date>September 2004</date>
            <title>Security Audit and Access Accountability Message - XML Data Definitions for Healthcare Applications</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc3881"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_3986">
            <abbrev>RFC 3986</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <date>January 2005</date>
            <title>Uniform Resource Identifier (URI): Generic Syntax</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc3986"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_4033">
            <abbrev>RFC 4033</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <date>March 2005</date>
            <title>DNS Security Introduction and Requirements</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc4033"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_4034">
            <abbrev>RFC 4034</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <date>March 2005</date>
            <title>Resource Records for the DNS Security Extensions</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc4034"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_4035">
            <abbrev>RFC 4035</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <date>March 2005</date>
            <title>Protocol Modifications for the DNS Security Extensions</title>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_5246">
            <abbrev>RFC 5246</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <date>August 2008</date>
            <title>The Transport Layer Security (TLS) Protocol Version 1.2</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc5246"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_5322">
            <abbrev>RFC 5322</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <date>October 2008</date>
            <title>Internet Message Format</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc5322"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_5424">
            <abbrev>RFC 5424</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <title>The Syslog Protocol</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc5424"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_5425">
            <abbrev>RFC 5425</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <title>Transport Layer Security (TLS) Transport Mapping for Syslog</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc5425"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_5426">
            <abbrev>RFC 5426</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <title>Transmission of Syslog Messages over UDP</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc5426"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_5652">
            <abbrev>RFC 5652</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <date>September 2009</date>
            <title>Cryptographic Message Syntax</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc5652"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_5905">
            <abbrev>RFC 5905</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <title>Network Time Protocol Version 4: Protocol and Algorithms Specification</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc5905"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_5906">
            <abbrev>RFC 5906</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <title>Network Time Protocol Version 4: Autokey Specification</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc5906"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_6762">
            <abbrev>RFC 6762</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <date>February 2013</date>
            <title>Multicast DNS</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc6762"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_6763">
            <abbrev>RFC 6763</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <date>February 2013</date>
            <title>DNS-Based Service Discovery</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc6763"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_8446">
            <abbrev>RFC 8446</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <date>August 2018</date>
            <title>The Transport Layer Security (TLS) Protocol Version 1.3</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc8446"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_8553">
            <abbrev>RFC 8553</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <title>DNS AttrLeaf Changes: Fixing Specifications That Use Underscored Node Names</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc8553"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_8633">
            <abbrev>RFC 8633</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <title>RFC8633 Network Time Protocol Best Current Practices</title>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc8633"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_8996">
            <abbrev>RFC 8996</abbrev>
            <authorgroup>
                <author>
                    <personname>Moriarty K</personname>
                </author>
                <author>
                    <personname>Farrell S</personname>
                </author>
            </authorgroup>
            <date>March 2021</date>
            <title>Deprecating TLS 1.0 and TLS 1.1</title>
            <releaseinfo>BCP 195</releaseinfo>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc8996"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_RFC_9325">
            <abbrev>RFC 9325</abbrev>
            <authorgroup>
                <author>
                    <personname>Sheffer Y</personname>
                </author>
                <author>
                    <personname>Saint-Andre P</personname>
                </author>
                <author>
                    <personname>Fossati T</personname>
                </author>
            </authorgroup>
            <date>Nov 2022</date>
            <title>Recommendations for Secure Use of Transport Layer Security (TLS) and Datagram Transport Layer Security (DTLS)</title>
            <releaseinfo>BCP 195. RFC 9325</releaseinfo>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/rfc9325"/>
            </bibliosource>
        </biblioentry>
        <biblioentry xml:id="biblio_BCP_195">
            <abbrev>BCP 195</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <title>Information on BCP 195</title>
            <releaseinfo>References RFC 8996 and RFC 9325</releaseinfo>
            <bibliosource>
                <link xl:href="http://www.rfc-editor.org/info/bcp195"/>
            </bibliosource>
        </biblioentry>
    </bibliography>

  </chapter>
    <chapter label="3" status="1" xml:id="chapter_3">
        <title>Definitions</title>
        <para xml:id="para_425a2b85-067d-4804-a1ef-06b8591dc028">For the purposes of this Standard the following definitions apply.</para>
        <glossary>
            <glossdiv label="3.1" status="2" xml:id="sect_3.1">
                <title>Reference Model Definitions</title>
                <para xml:id="para_0f6e7085-8eca-4dd2-877d-c74bed72e97f">This Part of the Standard makes use of the following terms defined in <xref linkend="biblio_ISO7498-1"/>:</para>
                <glossentry xml:id="glossentry_ApplicationEntity" xreflabel="Application Entity">
                    <glossterm>Application Entity</glossterm>
                    <glossdef>
                        <para xml:id="para_63725740-d6f5-4d37-8da2-b654a5b0f661">See <xref linkend="biblio_ISO7498-1"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_ProtocolDataUnit" xreflabel="Protocol Data Unit">
                    <glossterm>Protocol Data Unit</glossterm>
                    <glossdef>
                        <para xml:id="para_042fbdd2-f35e-4541-a8ba-e811396d3498">See <xref linkend="biblio_ISO7498-1"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_TransportConnection" xreflabel="Transport Connection">
                    <glossterm>Transport Connection</glossterm>
                    <glossdef>
                        <para xml:id="para_69b3ba3d-366a-4493-8971-79a7eea5f70a">See <xref linkend="biblio_ISO7498-1"/>.</para>
                    </glossdef>
                </glossentry>
            </glossdiv>
            <glossdiv label="3.2" status="2" xml:id="sect_3.2">
                <title>Reference Model Security Architecture Definitions</title>
                <para xml:id="para_372a4638-31e7-42b2-bbab-1fe6430a71e3">This Part of the Standard makes use of the following terms defined in <xref linkend="biblio_ISO7498-2"/>:</para>
                <glossentry xml:id="glossentry_DataConfidentiality" xreflabel="Data Confidentiality">
                    <glossterm>Data Confidentiality</glossterm>
                    <glossdef>
                        <para xml:id="para_d9a184bb-c1a0-4825-b3f7-90a914fc6bef">See <xref linkend="biblio_ISO7498-2"/>.</para>
                        <note>
                            <para xml:id="para_bba6609f-5984-47ac-894d-a9592ac6ccac">The definition is "the property that information is not made available or disclosed to unauthorized individuals, entities or processes."</para>
                        </note>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_DataOriginAuthentication" xreflabel="Data Origin Authentication">
                    <glossterm>Data Origin Authentication</glossterm>
                    <glossdef>
                        <para xml:id="para_4eee078c-9fb0-43bf-ae7d-c6813c75470e">See <xref linkend="biblio_ISO7498-2"/>.</para>
                        <note>
                            <para xml:id="para_46c27bb8-baba-40bb-994a-8faaed74c613">The definition is "the corroboration that the source of data received is as claimed."</para>
                        </note>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_DataIntegrity" xreflabel="Data Integrity">
                    <glossterm>Data Integrity</glossterm>
                    <glossdef>
                        <para xml:id="para_9aee9c73-0fd7-4dff-9fee-9857227a90cf">See <xref linkend="biblio_ISO7498-2"/>.</para>
                        <note>
                            <para xml:id="para_9b46d556-4cbc-4a55-8215-2c2398ecb457">The definition is "the property that data has not been altered or destroyed in an unauthorized manner."</para>
                        </note>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_KeyManagement" xreflabel="Key Management">
                    <glossterm>Key Management</glossterm>
                    <glossdef>
                        <para xml:id="para_9c22ec0f-9393-410e-a5d7-de7ef1ffa2cb">See <xref linkend="biblio_ISO7498-2"/>.</para>
                        <note>
                            <para xml:id="para_ca2d91e5-cbff-40d6-80f2-a750b6965069">The definition is "the generation, storage, distribution, deletion, archiving and application of keys in accordance with a security policy."</para>
                        </note>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_DigitalSignature" xreflabel="Digital Signature">
                    <glossterm>Digital Signature</glossterm>
                    <glossdef>
                        <para xml:id="para_8db745fe-a561-4b9a-835f-4715b302cec6">See <xref linkend="biblio_ISO7498-2"/>.</para>
                        <note>
                            <para xml:id="para_9bb66b6d-8cf0-4021-8a01-47bf3a023e98">The definition is "Data appended to, or a cryptographic transformation of, a data unit that allows a recipient of the data unit to prove the source and integrity of that unit and protect against forgery e.g., by the recipient."</para>
                        </note>
                    </glossdef>
                </glossentry>
            </glossdiv>
            <glossdiv label="3.3" status="2" xml:id="sect_3.3">
                <title>ACSE Service Definitions</title>
                <para xml:id="para_3144b980-f3d0-4396-a140-957e7faae735">This Part of the Standard makes use of the following terms defined in <xref linkend="biblio_ISO8649"/>:</para>
                <glossentry xml:id="glossentry_Association" xreflabel="Association">
                    <glossterm>Association</glossterm>
                    <glossdef>
                        <para xml:id="para_590170ec-444d-4b5e-979d-beec116141b4">See <xref linkend="biblio_ISO8649"/>.</para>
                    </glossdef>
                </glossentry>
            </glossdiv>
            <glossdiv label="3.4" status="2" xml:id="sect_3.4">
                <title>Security Definitions</title>
                <para xml:id="para_81d6bc48-f1e2-46b6-8c3f-8c59cbc26be3">This Part of the Standard makes use of the following terms defined in <xref linkend="biblio_ECMA235"/>:</para>
                
                    <glossentry xml:id="glossentry_SecurityContext" xreflabel="Security Context">
                        <glossterm>Security Context</glossterm>
                        <glossdef>
                            <para xml:id="para_b5acfa6e-9c92-4e05-84c8-fa6f840bfccb">See <xref linkend="biblio_ECMA235"/>.</para>
                            <note>
                                <para xml:id="para_42fe6fa4-83e1-4bdf-9cff-e1b089dce3de">The definition is "security information that represents, or will represent a Security Association to an initiator or acceptor that has formed, or is attempting to form such an association."</para>
                            </note>
                        </glossdef>
                    </glossentry>
                
            </glossdiv>
            <glossdiv label="3.5" status="2" xml:id="sect_3.5">
                <title>DICOM Introduction and Overview Definitions</title>
                <para xml:id="para_772e2211-cb8d-46ad-9028-d8dbbfd27b25">This Part of the Standard makes use of the following terms defined in <olink targetdoc="PS3.1" targetptr="PS3.1" xrefstyle="select: labelnumber"/>:</para>
                <glossentry xml:id="glossentry_Attribute" xreflabel="Attribute">
                    <glossterm>Attribute</glossterm>
                    <glossdef>
                        <para xml:id="para_d1cf5440-dc71-4fca-865e-f5ab74fbd5a1">
<olink targetdoc="PS3.1" targetptr="glossentry_Attribute" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_ServiceObjectPairClass" xreflabel="Service Object Pair Class (SOP Class)">
                    <glossterm>Service Object Pair Class</glossterm>
                    <acronym>SOP Class</acronym>
                    <glossdef>
                        <para xml:id="para_8f239752-1a29-4073-9b02-a07722b4249e">
<olink targetdoc="PS3.1" targetptr="glossentry_ServiceObjectPairClass" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
            </glossdiv>
            <glossdiv label="3.6" status="2" xml:id="sect_3.6">
                <title>DICOM Conformance Definitions</title>
                <para xml:id="para_553cd24f-8764-4949-a813-792f908bccaf">This Part of the Standard makes use of the following terms defined in <olink targetdoc="PS3.2" targetptr="PS3.2" xrefstyle="select: labelnumber"/>:</para>
                <glossentry xml:id="glossentry_SecurityProfile" xreflabel="Security Profile">
                    <glossterm>Security Profile</glossterm>
                    <glossdef>
                        <para xml:id="para_fb267161-4f7a-4cbc-bbcc-94b65ea0ccbe">
<olink targetdoc="PS3.2" targetptr="glossentry_SecurityProfile" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
            </glossdiv>
            <glossdiv label="3.7" status="2" xml:id="sect_3.7">
                <title>DICOM Information Object Definitions</title>
                <para xml:id="para_0d6890bd-5aae-41a9-8eb8-13a615f5b67b">This Part of the Standard makes use of the following terms defined in <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>:</para>
                <glossentry xml:id="glossentry_Module" xreflabel="Module">
                    <glossterm>Module</glossterm>
                    <glossdef>
                        <para xml:id="para_90f8af84-bcd8-4a12-b5da-166a465bea8f">
<olink targetdoc="PS3.3" targetptr="glossentry_Module" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
            </glossdiv>
            <glossdiv label="3.8" status="2" xml:id="sect_3.8">
                <title>DICOM Service Class Definitions</title>
                <para xml:id="para_9a40193f-b636-4d71-9a75-c8fc5ea03437">This Part of the Standard makes use of the following terms defined in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>:</para>
                <glossentry xml:id="glossentry_ServiceClass" xreflabel="Service Class">
                    <glossterm>Service Class</glossterm>
                    <glossdef>
                        <para xml:id="para_dfcea860-40ff-4b32-9d9f-1d6fa45a82d7">
<olink targetdoc="PS3.4" targetptr="glossentry_ServiceClass" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_ServiceObjectPairInstance" xreflabel="Service-Object Pair Instance (SOP Instance)">
                    <glossterm>Service-Object Pair Instance</glossterm>
                    <acronym>SOP Instance</acronym>
                    <glossdef>
                        <para xml:id="para_eaa393b0-f511-4c5e-8576-9c636ab4fb0f">
<olink targetdoc="PS3.4" targetptr="glossentry_ServiceObjectPairInstance" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
            </glossdiv>
            <glossdiv label="3.9" status="2" xml:id="sect_3.9">
                <title>DICOM Communication Support Definitions</title>
                <para xml:id="para_bbd62fbb-70f2-441d-aede-56d037f5fcc7">This Part of the Standard makes use of the following terms defined in <olink targetdoc="PS3.8" targetptr="PS3.8" xrefstyle="select: labelnumber"/>:</para>
                <glossentry xml:id="glossentry_DICOMUpperLayerService" xreflabel="DICOM Upper Layer Service">
                    <glossterm>DICOM Upper Layer Service</glossterm>
                    <glossdef>
                        <para xml:id="para_0c6477bc-a3a4-4e85-b29b-4c0a34a9e40b">
<olink targetdoc="PS3.4" targetptr="glossentry_DICOMUpperLayerService" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
            </glossdiv>
            <glossdiv label="3.10" status="2" xml:id="sect_3.10">
                <title>DICOM Security Profile Definitions</title>
                <para xml:id="para_b082c3e1-58c0-435b-9e1b-ffcb9694884d">The following definitions are commonly used in this Part of the DICOM Standard:</para>
                <glossentry xml:id="glossentry_SecureTransportConnection" xreflabel="Secure Transport Connection">
                    <glossterm>Secure Transport Connection</glossterm>
                    <glossdef>
                        <para xml:id="para_2d3a9a4e-5e97-4e99-87d9-ea5a7d143f75">A Transport Connection that provides some level of protection against tampering, eavesdropping, masquerading.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_MessageAuthenticationCode" xreflabel="Message Authentication Code">
                    <glossterm>Message Authentication Code</glossterm>
                    <glossdef>
                        <para xml:id="para_95a9bd8f-a16f-41d3-81df-c507cd25e0df">A digest or hash code derived from a subset of Data Elements.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_Certificate" xreflabel="Certificate">
                    <glossterm>Certificate</glossterm>
                    <glossdef>
                        <para xml:id="para_537e2a88-13a7-4bd9-9090-cca399101142">An electronic document that identifies a party and that party's public encryption algorithm, parameters, and key. The Certificate also includes, among other things, the identity and a digital signature from the entity that created the certificate. The content and format of a Certificate are defined by ITU-T Recommendation X.509.</para>
                    </glossdef>
                </glossentry>
            </glossdiv>
            <glossdiv label="3.11" status="2" xml:id="sect_3.11">
                <title>DICOM Data Structures and Encoding</title>
                <para xml:id="para_610d89dd-3a00-4b35-970c-fedc08f72303">This Part of the Standard makes use of the following terms defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>:</para>
                <glossentry xml:id="glossentry_DataElement" xreflabel="Data Element">
                    <glossterm>Data Element</glossterm>
                    <glossdef>
                    <para xml:id="para_251294f3-0b19-4fa2-9d5b-8d83f49c14d8">
                        <olink targetdoc="PS3.5" targetptr="glossentry_DataElement" xrefstyle="template:See %t in %o"/>.
                    </para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_DataSet" xreflabel="Data Set">
                    <glossterm>Data Set</glossterm>
                    <glossdef>
                        <para xml:id="para_30976a63-5ca4-46be-909f-4dff2addcf97">
                            <olink targetdoc="PS3.5" targetptr="glossentry_DataSet" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_DefinedTerm" xreflabel="Defined Term">
                    <glossterm>Defined Term</glossterm>
                    <glossdef>
                        <para xml:id="para_516659f3-7af4-4dfc-9d9a-d4bd66e5218e">
                            <olink targetdoc="PS3.5" targetptr="glossentry_DefinedTerm" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_EnumeratedValue" xreflabel="Enumerated Value">
                    <glossterm>Enumerated Value</glossterm>
                    <glossdef>
                        <para xml:id="para_5658f528-68b6-421d-813e-a7bd0b02b990">
                            <olink targetdoc="PS3.5" targetptr="glossentry_EnumeratedValue" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_GroupNumber" xreflabel="Group Number">
                    <glossterm>Group Number</glossterm>
                    <glossdef>
                        <para xml:id="para_87d518e7-03d5-4a39-8005-7c67ca32c565">
                            <olink targetdoc="PS3.5" targetptr="glossentry_GroupNumber" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
            </glossdiv>
            <glossdiv label="3.12" status="2" xml:id="sect_3.12">
                <title>Codes and Controlled Terminology Definitions</title>
                <para xml:id="para_00f54aee-1f33-4f3f-91db-9cb1c2a74039">This Part of the Standard makes use of the following terms defined in <olink targetdoc="PS3.16" targetptr="PS3.16" xrefstyle="select: labelnumber"/>:</para>
                <glossentry xml:id="glossentry_CodingScheme" xreflabel="Coding Scheme">
                    <glossterm>Coding Scheme</glossterm>
                    <glossdef>
                        <para xml:id="para_435fc4e3-efc6-41e8-87e7-7d7ea40b49e3">
                            <olink targetdoc="PS3.16" targetptr="glossentry_CodingScheme" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
            </glossdiv>
            <glossdiv label="3.13" status="2" xml:id="sect_3.13">
                <title>DICOM Media Storage and File Format Definitions</title>
                <para xml:id="para_25845497-3fca-475c-84d6-f9afeeeecdb8">This Part of the Standard makes use of the following terms defined in <olink targetdoc="PS3.10" targetptr="PS3.10" xrefstyle="select: labelnumber"/>:</para>
                <glossentry xml:id="glossentry_DICOMDIRFile" xreflabel="DICOMDIR File">
                    <glossterm>DICOMDIR File</glossterm>
                    <glossdef>
                        <para xml:id="para_53c184a6-5451-459a-91c4-8a1b2293c5c3">
                            <olink targetdoc="PS3.10" targetptr="glossentry_DICOMDIRFile" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_DICOMFile" xreflabel="DICOM File">
                    <glossterm>DICOM File</glossterm>
                    <glossdef>
                        <para xml:id="para_46442ca4-35ae-46d8-b1cc-c28e5af1d27f">
                            <olink targetdoc="PS3.10" targetptr="glossentry_DICOMFile" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_FileSet" xreflabel="File-set">
                    <glossterm>File-set</glossterm>
                    <glossdef>
                        <para xml:id="para_b9ae4af1-5185-4fd6-aefa-f9bc3b7d850e">
                            <olink targetdoc="PS3.10" targetptr="glossentry_FileSet" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
            </glossdiv>
        </glossary>
    </chapter>
    <chapter label="4" status="1" xml:id="chapter_4">
        <title>Symbols and Abbreviations</title>
        <para xml:id="para_de080f76-34d6-44ea-b29f-1d19d9f678da">The following symbols and abbreviations are used in this Part of the Standard.</para>
        <variablelist>
            <varlistentry>
                <term>ACR</term>
                <listitem>
                    <para xml:id="para_7aec1415-025b-4afc-9d1b-0e646aaaaba0">American College of Radiology</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>AE</term>
                <listitem>
                    <para xml:id="para_32d5295e-085f-4e64-b76b-d753c855c0a6">Application Entity</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>AES</term>
                <listitem>
                    <para xml:id="para_d1493852-ef64-400e-adb8-1e559bc2237c">Advanced Encryption Standard</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>ANSI</term>
                <listitem>
                    <para xml:id="para_29c2a7b6-acad-4b7b-ad8a-0c242cf8e125">American National Standards Institute</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>CEN TC251</term>
                <listitem>
                    <para xml:id="para_3e1cc7fa-15f6-4317-b3fe-9d98519f056b">Comite European de Normalisation-Technical Committee 251-Medical Informatics</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>CBC</term>
                <listitem>
                    <para xml:id="para_c99b7809-9352-4651-aeec-01ea1ca45c39">Cipher Block Chaining</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>CCIR</term>
                <listitem>
                    <para xml:id="para_717e4940-31cc-4e3b-a7d1-70afd9afde41">Consultative Committee, International Radio</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>CN</term>
                <listitem>
                    <para xml:id="para_2271bc18-2ec1-4ab1-ba45-429193272748">Common Name</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>DES</term>
                <listitem>
                    <para xml:id="para_ef6eafd2-300f-45c9-84d2-87f89e08edd6">Data Encryption Standard</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>DHCP</term>
                <listitem>
                    <para xml:id="para_364c08d4-a6dd-4805-a144-632cb547116e">Dynamic Host Configuration Protocol</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>DICOM</term>
                <listitem>
                    <para xml:id="para_3a54168e-e485-411d-b2a9-c52661d068d9">Digital Imaging and Communications in Medicine</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>DN</term>
                <listitem>
                    <para xml:id="para_ffe696ce-0794-4732-b242-d1dbf37a91b2">Distinguished Name</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>DNS</term>
                <listitem>
                    <para xml:id="para_f318a8e9-c338-4153-add6-a095e09aa3e3">Domain Name System</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>DDNS</term>
                <listitem>
                    <para xml:id="para_6184373a-68a1-415b-8bc8-a3f75b631f33">Dynamic Domain Name System</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>ECMA</term>
                <listitem>
                    <para xml:id="para_5a3aa14d-1239-4a24-bf8b-d9c62fb80bf6">European Computer Manufacturers Association</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>EDE</term>
                <listitem>
                    <para xml:id="para_5f7d1de0-45a6-4950-b758-1293b9df3e1b">Encrypt-Decrypt-Encrypt</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>HL7</term>
                <listitem>
                    <para xml:id="para_f660dacf-6b14-47b1-be6a-28bc27f6a5d9">Health Level 7</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>IEC</term>
                <listitem>
                    <para xml:id="para_c8ef3e47-5d57-43ca-9b1e-4f307b3fbe92">International Electrical Commission</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>IEEE</term>
                <listitem>
                    <para xml:id="para_d7aff20a-dad9-4f8e-ab4f-f11f929e1bb0">Institute of Electrical and Electronics Engineers</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>IETF</term>
                <listitem>
                    <para xml:id="para_d72edb1b-a264-4cab-9f89-a9b4f9c41702">Internet Engineering Task Force</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>IOD</term>
                <listitem>
                    <para xml:id="para_53d2022e-8bba-48fd-91d7-1c78349edf1c">Information Object Definition</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>ISCL</term>
                <listitem>
                    <para xml:id="para_22fbb5fa-7364-41cb-8e3d-feb31bd7850a">Integrated Secure Communication Layer</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>ISO</term>
                <listitem>
                    <para xml:id="para_93465f43-36bc-448e-9b44-c9fc15b9a6f4">International Standards Organization</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>JIRA</term>
                <listitem>
                    <para xml:id="para_96402fba-8455-4e41-b089-48b9d4d73844">Japan Medical Imaging and Radiological Systems Industries Association</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>LDAP</term>
                <listitem>
                    <para xml:id="para_8733e32d-3126-4e57-8926-250e063bca85">Lightweight Directory Access Protocol</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>LDIF</term>
                <listitem>
                    <para xml:id="para_6f8a5f75-c2f5-42c0-b956-fceaf33bf827">LDAP Interchange Format</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>MAC</term>
                <listitem>
                    <para xml:id="para_9ffb1950-7f11-43c6-be2a-63c87cd6e28a">Message Authentication Code</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>MD-5</term>
                <listitem>
                    <para xml:id="para_fb78aa8c-40ef-4128-abe2-128bdf50c0df">Message Digest - 5</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>MEDIS-DC</term>
                <listitem>
                    <para xml:id="para_dc4a3bf2-c541-44f3-bc7b-d4d2f45de0fe">Medical Information System Development Center</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>MPPS</term>
                <listitem>
                    <para xml:id="para_f6c387d5-cb16-4dc0-b9a4-e96b7c45d14c">Modality Performed Procedure Step</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>MTU</term>
                <listitem>
                    <para xml:id="para_d7ccc0ce-f52b-4210-8153-af6cb10057b0">Maximum Transmission Unit</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>NEMA</term>
                <listitem>
                    <para xml:id="para_46d33268-d3de-43c6-9481-d13f65de9c07">National Electrical Manufacturers Association</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>NTP</term>
                <listitem>
                    <para xml:id="para_caa4a632-c7a2-402a-9c8a-64b779d89e66">Network Time Protocol</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>OID</term>
                <listitem>
                    <para xml:id="para_fdd48b4d-d274-4a64-be7e-7d1abae5b1e5">Object Identifier (analogous to UID)</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>PDU</term>
                <listitem>
                    <para xml:id="para_0bffdf11-76f2-46f8-84cd-e1d5678f395e">Protocol Data Unit</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>RDN</term>
                <listitem>
                    <para xml:id="para_97f385cc-5726-4c78-ae11-c15e35942026">Relative Distinguished Name</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>RDSR</term>
                <listitem>
                    <para xml:id="para_ab0ecd7a-a54a-46eb-a2d0-ab2c9d47972d">Radiation Dose Structured Report</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>RFC</term>
                <listitem>
                    <para xml:id="para_77f8a96a-056f-45f3-89b8-87018705f011">Request For Comment (used for standards issued by the IETF)</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>RR</term>
                <listitem>
                    <para xml:id="para_e9e82e2e-71aa-4ebe-b108-500e35750ae4">Resource Record (when used in the context of DNS)</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>RSA</term>
                <listitem>
                    <para xml:id="para_93f28b20-7e28-451b-95cc-4ab86126154a">Rivest-Shamir-Adleman</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>SCP</term>
                <listitem>
                    <para xml:id="para_d8d81a4a-2a1d-4fb7-8a7a-c6d6726b1eb1">Service Class Provider</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>SCU</term>
                <listitem>
                    <para xml:id="para_22d0405f-30d1-46dd-8d89-0c70f9e0618f">Service Class User</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>SHA</term>
                <listitem>
                    <para xml:id="para_8a80f8ad-804e-4bfb-b9c8-c44a80f676a9">Secure Hash Algorithm</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>SNTP</term>
                <listitem>
                    <para xml:id="para_e0058068-7bcf-4ae7-a38b-fb498a7956cb">Simple Network Time Protocol</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>SOP</term>
                <listitem>
                    <para xml:id="para_0d0360e1-4fc2-463b-9940-1a6a6bfeb668">Service-Object Pair</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>SSH</term>
                <listitem>
                    <para xml:id="para_98a29eec-d52b-4d48-bfdd-2323d9701576">Secure Shell</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>SSL</term>
                <listitem>
                    <para xml:id="para_f40463a1-e733-46ae-9603-f9052440f213">Secure Sockets Layer</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>TLS</term>
                <listitem>
                    <para xml:id="para_6025cb8e-3887-4c80-bdbe-c72b0bad29a9">Transport Layer Security</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>UID</term>
                <listitem>
                    <para xml:id="para_bb6567ab-5863-41f7-939b-87f532f2ce6e">Unique Identifier</para>
                </listitem>
            </varlistentry>
            <varlistentry>
                <term>UTC</term>
                <listitem>
                    <para xml:id="para_b8a4211f-d98b-4347-bbfd-a3e2f76bd975">Universal Coordinated Time</para>
                </listitem>
            </varlistentry>
        </variablelist>
    </chapter>
<chapter label="5" status="1" xml:id="chapter_5">
    <title>Conventions</title>
  
  <para xml:id="para_4e0d5106-5563-4597-9ba8-868595b60a80">Terms listed in Section 3 Definitions are capitalized throughout the document.</para>
  </chapter>
<chapter label="6" status="1" xml:id="chapter_6">
    <title>Security and System Management Profile Outlines</title>
  
  <para xml:id="para_86115afc-c1cc-47a0-9533-c64db9dc9632">An implementation may claim conformance to any of the Security and System Management Profiles individually. It may also claim conformance to more than one Security or System Management Profile. It shall indicate in its Conformance Statement how it chooses which profiles to use for any given transaction.</para>
  <section label="6.1" status="2" xml:id="sect_6.1">
    <title>Secure Use Profiles</title>
  
  <para xml:id="para_6658494a-494f-46d6-99f1-d86481b16fbd">An implementation may claim conformance to one or more Secure Use Profiles. Such profiles outline the use of attributes and other Security Profiles in a specific fashion.</para>
  <para xml:id="para_14fa0667-5b25-4284-b07d-6a5ec5f992a9">Secure Use Profiles are specified in <xref linkend="chapter_A" xrefstyle="template:Annex %n"/>.</para>
  </section>
<section label="6.2" status="2" xml:id="sect_6.2">
    <title>Secure Transport Connection Profiles</title>
  
  <para xml:id="para_d8225da6-0579-41f1-b44a-11876d371809">An implementation may claim conformance to one or more Secure Transport Connection Profiles.</para>
  <para xml:id="para_2e1a10eb-52fa-4c71-a93d-227dccfebed6">A Secure Transport Connection Profile includes the following information:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_781ae956-d9c0-457d-a94e-eb4ed32bd6b3">Description of the protocol framework and negotiation mechanisms</para>
</listitem>
<listitem>
<para xml:id="para_f716012e-9d0f-4437-beb5-4fb1e48c9db8">Description of the entity authentication an implementation shall support</para>
      <orderedlist numeration="arabic">
        <listitem>
<para xml:id="para_7dd42506-fcfa-4f57-8572-5bd80cd4c60e">The identity of the entities being authenticated</para>
</listitem>
        <listitem>
<para xml:id="para_1dcbbfb2-c989-4fa2-8667-f7fb9ba92535">The mechanism by which entities are authenticated</para>
</listitem>
        <listitem>
<para xml:id="para_02968471-e870-455c-b18f-a1ea9beebaf5">Any special considerations for audit log support</para>
</listitem>
      </orderedlist>
      
        
        
    </listitem>
    <listitem>
      <para xml:id="para_20bb8c68-ea13-412f-834f-6d81c9cabbe8">Description of the encryption mechanism an implementation shall support</para>
      <orderedlist numeration="arabic">
        <listitem>
<para xml:id="para_b99e76f2-0a44-4485-875b-b1fd8fca47b0">The method of distributing session keys</para>
</listitem>
        <listitem>
<para xml:id="para_4616555b-38b3-40ce-908c-7cd98f1d7eec">The encryption protocol and relevant parameters</para>
</listitem>
      </orderedlist>
      
        
        
    </listitem>
    <listitem>
<para xml:id="para_ad340f0d-a993-451e-a454-6c68f1141285">Description of the integrity check mechanism an implementation shall support</para>
</listitem>
  </orderedlist>
  <para xml:id="para_8ce3b894-57a2-4eb8-8231-40727eada4e9">Secure Transport Connection Profiles are specified in <xref linkend="chapter_B" xrefstyle="template:Annex %n"/>.</para>
  </section>
<section label="6.3" status="2" xml:id="sect_6.3">
    <title>Digital Signature Profile</title>
  
  <para xml:id="para_7daeec93-d93e-4f30-86c0-ffdcb2fd0bd1">An implementation may claim conformance to one or more Digital Signature Profiles.</para>
  <para xml:id="para_55a4cbed-6089-46f3-abe6-ccc79cc52e9b">A Digital Signature profile consists of the following information:</para>
  <orderedlist numeration="loweralpha">
    <listitem>
<para xml:id="para_f0c6a720-64b1-4fa7-9363-628770bd4a14">The role that the Digital Signature plays, including:</para>
  <orderedlist numeration="arabic">
    <listitem>
<para xml:id="para_7edb768f-f423-4949-acaa-7a1a8143fc17">Who or what entity the Digital Signature represents.</para>
</listitem>
    <listitem>
<para xml:id="para_ac7b80c5-4966-42e3-b435-4c8478b27e02">A description of the purpose of the Digital Signature.</para>
</listitem>
    <listitem>
<para xml:id="para_27d3adb2-0f80-47fc-b61e-c5f47c9369c9">The conditions under which the Digital Signature is included in the Data Set.</para>
</listitem>
  </orderedlist>
    </listitem>
    <listitem>
<para xml:id="para_619d0f11-c75b-44c9-b69f-b6197080fc4a">A list of Attributes that shall be included in the Digital Signature.</para>
</listitem>
    <listitem>
<para xml:id="para_a09f5b71-5a61-473e-a78c-707bf187aefc">The mechanisms that shall be used to generate or verify the Digital Signature, including:</para>
      <orderedlist numeration="arabic">
        <listitem>
<para xml:id="para_90f5d9ca-241a-422b-bb55-e41560040395">The algorithm and relevant parameters that shall be used to create the MAC or hash code, including the Value to be used for the MAC Algorithm (0400,0015) Attribute.</para>
</listitem>
        <listitem>
<para xml:id="para_43695001-8864-4f3b-9748-d3dda885ec8b">The encryption algorithm and relevant parameters that shall be used to encrypt the MAC or hash code in forming the Digital Signature.</para>
</listitem>
        <listitem>
<para xml:id="para_16e15e3f-e7c8-4aac-9048-fd828c044c22">The certificate type or key distribution mechanism that shall be used, including the Value to be used for the Certificate Type (0400,0110) Attribute.</para>
</listitem>
        <listitem>
<para xml:id="para_ea9726ed-07bc-45aa-9ef6-379882f3b4a7">Any requirements for the Certified Timestamp Type (0400,0305) and Certified Timestamp (0400,0310) Attributes.</para>
</listitem>
      </orderedlist>
    </listitem>
    <listitem>
<para xml:id="para_55e414df-28d7-4f31-81c2-64a853033a51">Any special requirements for identifying the signatory.</para>
</listitem>
    <listitem>
<para xml:id="para_c8696dec-d693-4758-8144-191c79705a1e">The relationship with other Digital Signatures, if any.</para>
</listitem>
    <listitem>
<para xml:id="para_71be3f29-ddbb-41a0-bb66-59078c767b66">Any other factors needed to create, verify, or interpret the Digital Signature</para>
</listitem>
  </orderedlist>
  
  <para xml:id="para_8a0a22ea-dae9-463e-a82c-2a1582d1abd8">Digital Signature Profiles are specified in <xref linkend="chapter_C" xrefstyle="template:Annex %n"/>.</para>
  </section>
<section label="6.4" status="2" xml:id="sect_6.4">
    <title>Media Storage Security Profiles</title>
  
  <para xml:id="para_a130d511-58a6-4388-8754-9f2b724801ef">An implementation may claim conformance to one or more Media Storage Application Profiles, which in turn require conformance to one or more Media Storage Security Profiles.</para>
  <note>
    <para xml:id="para_4335a6f3-d242-433a-b305-f41352ac5148">An implementation may not claim conformance to a Media Storage Security Profile without claiming conformance to a Media Storage Application Profile.</para>
  </note>
  <para xml:id="para_b95b8e50-4ee1-4a7d-b0d0-45236a5492a2">A Media Storage Security Profile includes the following specifications:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_90675312-3487-418e-b0f9-905157a7d9b3">What aspects of security are addressed by the profile.</para>
</listitem>
<listitem>
<para xml:id="para_1acfd068-aa90-4881-b5fd-43fc67a8dccd">The restrictions on the types of DICOM Files that can be secured, if any.</para>
</listitem>
<listitem>
<para xml:id="para_54046682-7c8b-476d-a1e1-b2b217b0bcde">How the DICOM Files will be encapsulated and secured.</para>
</listitem>
</orderedlist>
  <para xml:id="para_3669e02e-11e9-4670-9c94-92c3e7c99e0e">Media Storage Security Profiles are specified in <xref linkend="chapter_D" xrefstyle="template:Annex %n"/>.</para>
  </section>
<section label="6.5" status="2" xml:id="sect_6.5">
    <title>Network Address Management Profiles</title>
  
  <para xml:id="para_57118051-74b7-4a7c-b2ef-4dc3722c285b">An implementation may claim conformance to one or more Network Address Management Profiles. Such profiles outline the use of non-DICOM network protocols to obtain the network addresses for the implementation.</para>
  <para xml:id="para_9263ad8a-a9ca-4dc9-98d3-5354dc28d3eb">Network Address Management Profiles are specified in <xref linkend="chapter_F" xrefstyle="template:Annex %n"/>.</para>
  </section>
<section label="6.6" status="2" xml:id="sect_6.6">
    <title>Time Synchronization Profiles</title>
  
  <para xml:id="para_cde9865a-e99b-49a9-a9f8-28a106e8c64d">An implementation may claim conformance to one or more Time Synchronization Profiles. Such profiles outline the use of non-DICOM protocols to set the current time for the implementation.</para>
  <para xml:id="para_dee998b5-ff88-43d2-9843-da57d99e78b8">Time Synchronization Profiles are specified in <xref linkend="chapter_G" xrefstyle="template:Annex %n"/>.</para>
  </section>
<section label="6.7" status="2" xml:id="sect_6.7">
    <title>Application Configuration Management Profiles</title>
  
  <para xml:id="para_d6c9a35b-10ab-486f-a0df-5683367d0598">An implementation may claim conformance to one or more Application Configuration Management Profiles. Such profiles outline the use of non-DICOM network protocols to obtain the descriptions, addresses and capabilities of other devices with which the implementation may communicate using the DICOM Protocol. They also specify the use of those non-DICOM protocols for the implementation to publish or announce its description, addresses and capabilities. They also specify how implementation specific configuration information can be obtained by devices.</para>
  <para xml:id="para_dd022135-157d-49f0-ac05-315ae6ef64eb">Application Configuration Management Profiles are specified in <xref linkend="chapter_H" xrefstyle="template:Annex %n"/>.</para>
  </section>
<section label="6.8" status="2" xml:id="sect_6.8">
    <title>Audit Trail Profiles</title>
  
  <para xml:id="para_6be82387-6dcb-43fc-b306-569472bceee2">An implementation may claim conformance to one or more Audit Trail Profiles. Such profiles outline the generation and transport of audit messages for security and privacy policy enforcement.</para>
  <para xml:id="para_5a91f502-933d-4666-8004-44648c9f670d">Audit Trail Profiles are specified in <xref linkend="chapter_A" xrefstyle="template:Annex %n"/>.</para>
  </section>
    <section label="6.9" status="2" xml:id="sect_6.9">
        <title>Attribute Confidentiality Profiles</title>
        <para xml:id="para_6ed2b63c-08d5-472e-9add-aa7dbed4fb73">An implementation may claim conformance to the Basic Application Level Confidentiality Profile and to one or more Basic Application Level Confidentiality Options.
            This profile and options support the de-identification of Data Sets to prevent leakage of individually identifiable information, for reasons of privacy.</para>
        <para xml:id="para_9f9faa08-ead2-4888-a04b-2a26d4f58bbd">The Basic Application Level Confidentiality Profile and its Options are specified in <xref linkend="chapter_E" xrefstyle="template:Annex %n"/>.</para>
    </section>
</chapter>
<chapter label="7" status="1" xml:id="chapter_7">
    <title>Configuration Profiles</title>
  
  <para xml:id="para_dc2f1c52-71db-4ea2-b304-e9676bda8dfa">Configuration management support is implemented by means of protocols defined in standards other than the DICOM Standard. These protocols are described here in terms of actors, transactions, and profiles.</para>
  <para xml:id="para_8c6a3149-8e67-4bad-9c08-8910f9f4c002">Actors are analogous to the Application Entities used within the DICOM profile. An actor is a collection of hardware and software processes that perform a particular role. When a device provides or uses a service it will include an actor to handle the relevant network activity. DICOM Configuration actors may co-exist with other Application Entities on a device. Some DICOM Configuration actors exist as parts of general use IT equipment. Like the Application Entity, specification of an Actor does not imply anything about the details of the actual implementation.</para>
  <para xml:id="para_b1f183be-bb9e-4f5b-914a-6c677aaf0717">The actor interactions are defined in terms of Transactions. Each transaction is given a name. The transaction may in turn comprise a variety of activity. All transactions are defined in terms of actors that are communicating. The relationships between actors in a transaction may be more complex than the simple SCU and SCP roles in DICOM activities. When the transaction includes interactions with a person, the transactions may be implemented by user interfaces, removable media. and other mechanisms. The person is described in terms of being an actor from the perspective of the transaction use case model. More typically the transactions are a series of network activities that perform a specific operation.</para>
  <para xml:id="para_68cd0ccc-dea2-4018-b904-86c359522991">A transaction includes both mandatory and optional components. An Actor that is implementing a transaction is required to implement all of the mandatory components.</para>
  <para xml:id="para_334a2754-0b9e-4b0f-9e44-4afbe3342552">Some transactions include human actors in the transaction definition. These actors are not defined as actors elsewhere, nor are they included in profile descriptions. They exist to specify that some sort of mechanism must be provided to permit these people to interact with the computer actor. Other details of how that user interface is provided are not specified by this Standard. For an example, see the definition of the Configure DHCP transaction.</para>
  <para xml:id="para_853b211e-997a-4485-bd7c-253e94ed1941">Conformance is further managed by means of Profiles. A Profile is defined in terms of what transactions are required for an actor and what transactions are optional. An implementation of a specific actor is documented by specifying what optional transactions and transaction components have been implemented. An implementation that omits any required transactions or components cannot claim to be an implementation of that Actor.</para>
  <para xml:id="para_12c6ba3d-f47a-4cc8-bedc-8cce28fb4985">For example, in the Network Address Management Profile the DHCP Server is required to perform the three Transactions to configure the DHCP server, find and use DHCP servers, and maintain the DHCP leases. It may also support the transaction to update the DNS server by means of DDNS coordination.</para>
  <para xml:id="para_cff905e0-1697-4db4-998d-f4f72b616faa">A Profile includes definitions for more than one Actor. It specifies the transactions for all of the actors that cooperate to perform a function. For example, the Network Address Management Profile covers the DHCP Server actor, the DHCP client Actor, and the DNS Server actor. There must be at least one DHCP Server and one DHCP Client for the system to be useful. The DNS Server itself is optional because the DHCP Server need not implement the DDNS Coordination transaction. If the DNS Server is part of the system, the DDNS coordination is required and the DHCP Server will be expected to participate in the DDNS Coordination transaction.</para>
  <note>
    <para xml:id="para_7a3f2a2b-2839-47ca-81b4-857dd9da4226">There may be a DNS server present on the same network as a DHCP Server, but if it is not providing the DNS Server actor from this profile it is not part of the DICOM Configuration activities.</para>
  </note>
  <para xml:id="para_a4d58880-1196-47e4-9013-8664ef3a9e07">The profiles, actors, and transactions are summarized in the following sections. The detailed description of actor and transactions for each specific profile are described in annexes for each profile. The transactions are documented in terms of parameters and terms from their original standards document, e.g., an RFC for Internet protocols. The full details of the transaction are not described in the annex, only particular details that are relevant to the DICOM application of that transaction. The complete details for these external protocols are documented in the relevant standards documents for the external protocols. Compliance with the requirements of a particular profile shall include compliance with these external protocol documents.</para>
  <section label="7.1" status="2" xml:id="sect_7.1">
    <title>Actors</title>
  
  <para xml:id="para_a032422d-7539-42cf-a1c0-9d8b8ddfeb5f">
    <emphasis role="bold">DHCP Server</emphasis>
  </para>
  <para xml:id="para_e1fbd902-3615-4945-868f-4c3876c8882c">
  The DHCP Server is a computer/software feature that is provided with a network configuration description, and that provides startup configuration services in accordance with the DHCP protocol.</para>
  <para xml:id="para_e05f141b-12e9-42d8-8561-e60fb7bb237d">
    <emphasis role="bold">DHCP Client</emphasis>
  </para>
  <para xml:id="para_62d88963-58bd-4295-a3d7-ff1d9ae755fe">
  The DHCP Client is a software feature that is used to obtain TCP/IP parameters during the startup of a computer. It continues operation to maintain validity of these parameters.</para>
  <para xml:id="para_9f00fdce-f44b-4832-853c-8c1ef3e00add">
    <emphasis role="bold">DNS Server</emphasis>
  </para>
  <para xml:id="para_18e6ac6b-ed5c-4112-9191-5eca990cc208">The DNS server is a computer/software feature that provides IP related information in response to queries from clients utilizing the DNS protocol. It is a part of a federated database facility that maintains the current database relating machine names to IP address information. The DNS server may also be isolated from the worldwide federated database and provide only local DNS services.</para>
  <para xml:id="para_c7b2acff-c897-449e-b3f5-035aff08a1f6">
    <emphasis role="bold">DNS Client</emphasis>
  </para>
  <para xml:id="para_16ebd010-fcbb-4eab-a323-bc522a718183">The DNS client as a computer/software feature that utilizes the DNS protocols to obtain IP information when given hostnames. The hostnames may be in configuration files or other files instead of explicit IP addresses. The hostnames are converted into IP addresses dynamically when necessary. The DNS client uses a DNS server to provide the necessary information.</para>
  <para xml:id="para_a76c184d-113c-4e31-9fe5-9139d4201726">
    <emphasis role="bold">NTP Server</emphasis>
  </para>
  <para xml:id="para_e46ce772-1722-40c2-ac5f-c5ca93758f03">
  The NTP server is a computer/software feature that provides time services in accordance with the NTP or SNTP protocol.</para>
  <para xml:id="para_3374ec20-1865-4461-b100-dee9bcd291c3">
    <emphasis role="bold">NTP Client</emphasis>
  </para>
  <para xml:id="para_77927d42-b8a5-4838-837a-2931682dfedf">
  The NTP client is software that obtains time information from an NTP server and maintains the client time in synchronization with the time signals from the NTP server.</para>
  <para xml:id="para_d889996a-b8c4-47d7-a186-77990289be81">
    <emphasis role="bold">SNTP Client</emphasis>
  </para>
  <para xml:id="para_36960c00-9e3e-4c29-b69c-5d401772cdcb">
  The SNTP client is software that obtains time information from an NTP server and maintains the client time in approximate synchronization with time signals from the NTP server. The SNTP client synchronization is not maintained with the accuracy or precision that NTP provides.</para>
  <para xml:id="para_77404b3f-a663-40e2-b152-d02321ed6520">
    <emphasis role="bold">LDAP Server</emphasis>
  </para>
  <para xml:id="para_690baf18-c06d-4da8-9350-fc1752d17b68">
  The LDAP server is a computer/ software feature that maintains an internal database of various directory information. Some of this directory information corresponds to DICOM Configuration schema. The LDAP server provides network access to read and update the directory information. The LDAP server provides a mechanism for external loading, unloading, and backup of directory information. The LDAP server may be part of a federated network of servers that provides a coordinated view of a federated directory database in accordance with the rules of the LDAP protocols.</para>
  <para xml:id="para_68c287d6-b181-4958-ab59-31ad770a3a77">
    <emphasis role="bold">LDAP Client</emphasis>
  </para>
  <para xml:id="para_f5ad463f-8088-46dd-97cc-e40fdd34db4b">
  The LDAP client utilizes the LDAP protocol to make queries to an LDAP server. The LDAP server maintains a database and responds to these queries based on the contents of this database.</para>
  </section>
<section label="7.2" status="2" xml:id="sect_7.2">
    <title>Transactions</title>
  
  <para xml:id="para_6a03c836-3f4e-4888-8155-e3d5e855fd1f">The following transactions are used to provide communications between actors in accordance with one or more of the DICOM Configuration protocols.</para>
  <para xml:id="para_0dea5a18-8f78-4dfa-a416-40cdab0bb25c">
    <emphasis role="bold">Configure DHCP Server</emphasis>
  </para>
  <para xml:id="para_510234d7-1de8-4695-9537-e9e79d5e97d7">This transaction changes the configuration on a DHCP server to reflect additions, deletions, and changes to the IP parameters that have been established for this network.</para>
  <para xml:id="para_ad92adc9-8bbe-4b67-a9ce-a544ffca3537">
    <emphasis role="bold">Find and Use DHCP Server</emphasis>
  </para>
  <para xml:id="para_f17f5903-f217-4e0d-aa88-42e51de37794">This transaction is a sequence of network messages that comply with the rules of the DHCP protocol. It allows a DHCP client to find available DHCP servers and select the server appropriate for that client. This transaction obtains the mandatory IP parameter information from the DHCP server and obtains additional optional parameters from the DHCP server.</para>
  <para xml:id="para_0dff431b-aa2f-4afb-b04d-2a3e031a2a17">
    <emphasis role="bold">Configure Client</emphasis>
  </para>
  <para xml:id="para_ab5d4c3e-68a0-4375-8f6c-5ba94d7ee773">The service staff uses this transaction to set the initial configuration for a client.</para>
  <para xml:id="para_d565805b-ef84-4b3c-8109-b7809aa283ba">
    <emphasis role="bold">Maintain Lease</emphasis>
  </para>
  <para xml:id="para_672dae05-c8f2-408f-8713-e15df8fc44af">This transaction deals with how the DHCP client should behave when its IP lease is not renewed.</para>
  <para xml:id="para_bf73d72a-627f-4903-895f-7ae2a648bb6e">
    <emphasis role="bold">DDNS Coordination</emphasis>
  </para>
  <para xml:id="para_026d3e6e-2eb3-4729-9b57-16abd47dc613">This transaction documents whether the DHCP server is coordinating with a DNS server so that access to the DHCP client can be maintained using the hostname assigned to the DHCP client.</para>
  <para xml:id="para_cd64f128-3a7f-4713-80c9-c9dd10266c48">
    <emphasis role="bold">Resolve Hostname</emphasis>
  </para>
  <para xml:id="para_8c476946-c1ff-48e0-9747-65471521dd52">
  This transaction obtains the IP address for a computer when given a hostname.</para>
  <para xml:id="para_6005ef70-528e-4617-8524-7b0a5053606c">
    <emphasis role="bold">Maintain Time</emphasis>
  </para>
  <para xml:id="para_3f1ec4d8-bad1-490a-ae7a-dcaa71177554">These transactions are the activities needed for an NTP or SNTP client to maintain time synchronization with a master time service.</para>
  <para xml:id="para_b9c63cf5-2707-45fe-8b96-a707b5200db9">
    <emphasis role="bold">Find NTP Server</emphasis>
  </para>
  <para xml:id="para_76db9225-417d-4bbf-b0eb-4ff3eed1bd01">This transaction is the autodiscovery procedure defined for NTP. This may use either a broadcast method or a DHCP supported method.</para>
  <para xml:id="para_b3c171d3-24d9-48ea-b73e-563d964d1728">
    <emphasis role="bold">Find LDAP Server</emphasis>
  </para>
  <para xml:id="para_ec818868-6c7b-48f7-bc2f-34a19e68ad63">In this transaction the DNS server is queried to obtain the IP address, port, and name of the LDAP server.</para>
  <para xml:id="para_77b1b637-4411-448e-b828-2176c1d9a30e">
    <emphasis role="bold">Query LDAP Server</emphasis>
  </para>
  <para xml:id="para_4c06e4b1-bf37-49b5-aea7-481da2a1bd28">
  In this transaction the LDAP server is queried regarding contents of the LDAP database.</para>
  <para xml:id="para_c072b153-6e99-4282-9b00-a4aa40085361">
    <emphasis role="bold">Client Update LDAP Server</emphasis>
  </para>
  <para xml:id="para_bbddf2b5-886b-490f-8721-b5c8e3860700">This transaction updates the configuration database using LDAP update instructions from the client being configured.</para>
  <para xml:id="para_98364599-8302-48f4-bf3c-e8681da06f12">
    <emphasis role="bold">Maintain LDAP Server</emphasis>
  </para>
  <para xml:id="para_5608b6bd-6fc2-4d38-b864-84b33f2ade0c">This transaction updates the configuration database using local services of the LDAP server.</para>
  <para xml:id="para_9db34eac-b67b-4bfc-844a-593e5f76e1c9">
<xref linkend="figure_7-1" xrefstyle="select: label"/> shows the actors and their transactions. The usual device will have an NTP Client, DHCP Client, and LDAP client in addition to the other applications actors. The transactions "Configure DHCP Server", "Configure Client", and "Maintain LDAP Server" are not shown because these transactions are between a software actor and a human actor. DICOM does not specify the means or user interface. It only requires that certain capabilities be supported.</para>
  <para xml:id="para_12b0b4da-150c-45d9-ad23-1147bdea74b9">
  <figure label="7-1" pgwide="1" xml:id="figure_7-1">
    <title>Transactions and Actors</title>
    <mediaobject>
      <imageobject>
        <imagedata fileref="figures/PS3.15_7-1.svg"/>
        <!--<imagedata fileref="part15_fromword_files/image002.png"/>-->
      </imageobject>
    </mediaobject>
  </figure>
</para>
  </section>
</chapter>
    <chapter label="A" status="1" xml:id="chapter_A">
        <title>Secure Use Profiles (Normative)</title>

        <section label="A.1" status="2" xml:id="sect_A.1">
            <title>Online Electronic Storage Secure Use Profile</title>

            <para xml:id="para_c4ab3f0c-517b-496a-a6e1-265c7cb00ddd">The Online Electronic Storage Secure Use Profile allows Application Entities to track and verify the status of SOP Instances in those cases where local security policies require tracking of the original Data Set and subsequent copies.</para>
            <para xml:id="para_faf7e7e4-4667-49f1-b0ca-39b58ead6699">The Conformance Statement shall indicate in what manner the system restricts remote access.</para>
            <section label="A.1.1" status="3" xml:id="sect_A.1.1">
                <title>SOP Instance Status</title>

                <para xml:id="para_19fb0855-6226-4fc0-b846-7cc568082d17">An implementation that conforms to the Online Electronic Storage Secure Use Profile shall conform to the following rules regarding the use of the SOP Instance Status (0100,0410) Attribute with SOP Instances that are transferred using the Storage Service Class:</para>
                <orderedlist numeration="loweralpha">
                    <listitem>
                        <para xml:id="para_4b216cc5-2d0d-49fe-b743-737013cb32ab">An Application Entity that supports the Online Electronic Storage Secure Use Profile and that creates a SOP Instance intended for diagnostic use in Online Electronic Storage shall:</para>
                        <orderedlist numeration="arabic">
                            <listitem>
                                <para xml:id="para_90235bc7-799a-479c-9df2-b3eada974465">Set the SOP Instance Status to Original (OR).</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_1d11c196-86c3-4150-98b6-bf3a7910f19b">Include the following Attributes:</para>
                                <orderedlist numeration="lowerroman">
                                    <listitem>
                                        <para xml:id="para_eb3512d4-3c40-48bd-9371-66b26ea78ee7">the SOP Class UID (0008,0016) and SOP Instance UID (0008,0018)</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_febbb3eb-ce93-4cd4-a280-cca17e6db64b">the Instance Creation Date (0008,0012) and Instance Creation Time (0008,0013), if known</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_aea0b394-6cd6-4ade-9c2f-6252e7382a5d">the SOP Instance Status</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_ac59127e-8a6d-4fdb-b9f5-d62bade16a79">the SOP Authorization Date and Time (0100,0420)</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_55cdbbfd-6558-4b28-9d0f-a2470df93ff7">the SOP Authorization Comment, if any (0100,0424)</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_ebac1a20-6570-4887-a57f-ade5320d1c30">the SOP Equipment Certification Number (0100,0426)</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_cf95f5aa-9d48-4254-b14b-2126d37fc102">the Study Instance UID (0020,000D) and Series Instance UID (0020,000E)</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_ef0c9fe3-417e-498a-a81f-0ae02007d234">any Attributes of the General Equipment Module that are known</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_4f93624e-73b3-458d-9d0d-c660036a13c4">any overlay data present</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_70dbdb07-a06d-4fab-8c21-a688aafeb66c">any image data present</para>
                                    </listitem>
                                </orderedlist>
                            </listitem>
                        </orderedlist>
                    </listitem>
                    <listitem>
                        <para xml:id="para_2e067f44-7d99-4096-ac6a-f32611139c7a">The Application Entity that holds a SOP Instance where the SOP Instance Status is Original (OR) may change the SOP Instance Status to Authorized Original(AO) as long as the following rules are followed:</para>
                        <orderedlist numeration="arabic">
                            <listitem>
                                <para xml:id="para_033ddbf9-cd5f-429c-8c35-73dd6d45dce5">The Application Entity shall determine that an authorized entity has certified the SOP Instance as useable for diagnostic purposes.</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_bd5e416a-5e0c-4dda-9940-d518fc04ee01">The Application Entity shall change the SOP Instance Status to Authorized Original (AO). The SOP Instance UID shall not change.</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_ca81946b-ad66-492f-8188-03856a3a668e">The Application Entity shall set the SOP Authorization Date and Time (0100,0420) and Authorization Equipment Certification Number (0100,0426) Attributes to appropriate Values. It may also add an appropriate SOP Authorization Comment (0100,0424) Attribute.</para>
                            </listitem>
                        </orderedlist>
                    </listitem>
                    <listitem>
                        <para xml:id="para_01172bf7-b6ce-4e6c-ad02-34e138eab77f">There shall only be one Application Entity that holds a SOP Instance where the SOP Instance Status is Original (OR) or Authorized Original (AO). The Application Entity that holds such a SOP instance shall not delete it.</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_4f42e0f7-1721-46b9-824b-16bc65828587">When communicating with an Application Entity that supports Online Electronic Storage the Application Entity that holds a SOP Instance where the SOP Instance Status is Original(OR) or Authorized Original(AO) may transfer that SOP Instance to another Application Entity that also conforms to the Online Electronic Storage Secure Use Profile as long as the following rules are followed:</para>
                        <orderedlist numeration="arabic">
                            <listitem>
                                <para xml:id="para_f5020c27-f802-4d54-85d6-feca4bf1e5be">The transfer shall occur on a Secure Transport Connection.</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_3eddb027-f9b3-4c8e-8966-df59fad99013">The two Application Entities involved in the transfer shall authenticate each other and shall confirm via the authentication that the other supports the Online Electronic Storage Secure Use Profile.</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_29273f57-50f4-4d11-b0e3-aa246e4f9566">The receiving Application Entity shall reject the storage request and discard the received SOP Instance if the data integrity checks done after the transfer indicate that the SOP Instance was altered during transmission.</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_513515e8-37ba-4aa6-bb31-adb1728abb82">The transfer shall be confirmed using the push model of the Storage Commitment Service Class. Until it has completed this confirmation, the receiving Application Entity shall not forward the SOP Instance or Authorized Copies of the SOP instance to any other Application Entity.</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_7fa325cd-d7e1-4dd5-8a6c-e95c1f6a251d">Once confirmed that the receiving Application Entity has successfully committed the SOP Instance to storage, the sending Application Entity shall do one of the following to its local copy of the SOP Instance:</para>
                                <orderedlist numeration="lowerroman">
                                    <listitem>
                                        <para xml:id="para_a0043f29-1054-4d4e-8919-089811ba50a2">delete the SOP Instance,</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_56ae0a3e-664a-4075-a3f9-cf2aec7c8ddd">change the SOP Instance Status to Not Specified (NS),</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_550aa1b7-c137-41ca-a0e3-adac01eecbd3">if the SOP Instance Status was Authorized Original (AO), change the SOP Instance Status to Authorized Copy (AC).</para>
                                    </listitem>
                                </orderedlist>
                            </listitem>
                        </orderedlist>
                    </listitem>
                    <listitem>
                        <para xml:id="para_69126e0c-6074-42bc-9d71-4c05bbdff5b1">When communicating with an Application Entity that supports Online Electronic Storage an Application Entity that holds a SOP Instance whose SOP Instance Status is Authorized Original (AO) or Authorized Copy (AC) may send an Authorized Copy of the SOP Instance to another Application Entity as long as the following rules are followed:</para>
                        <orderedlist numeration="arabic">
                            <listitem>
                                <para xml:id="para_031be780-04cb-4d13-a4a0-a3c1e9ba19b4">The transfer shall occur on a Secure Transport Connection.</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_bcf01fd2-d27d-48e9-992d-f85c7eef9a98">The two Application Entities involved in the transfer shall authenticate each other, and shall confirm via the authentication that the other supports the Online Electronic Storage Secure Use Profile.</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_c8daf194-d6ff-4308-a5b7-0e6d95c7816d">The sending Application Entity shall set the SOP Instance Status to either Not Specified (NS) or Authorized Copy (AC) in the copy sent. The SOP Instance UID shall not change.</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_e859b577-3806-4567-b9c6-d1df18c07a62">The receiving Application Entity shall reject the storage request and discard the copy if data integrity checks done after the transfer indicate that the SOP Instance was altered during transmission.</para>
                            </listitem>
                        </orderedlist>
                    </listitem>
                    <listitem>
                        <para xml:id="para_59108bee-24f8-4033-8457-eaf61dd3f516">If communicating with a system that does not support the Online Electronic Storage Secure Use Profile, or if communication is not done over a Secure Transport Connection, then</para>
                        <orderedlist numeration="arabic">
                            <listitem>
                                <para xml:id="para_9c7ff623-bdfb-465f-b0f6-419593ffc22a">A sending Application Entity that conforms to this Security Profile shall either set the SOP Instance Status to Not Specified (NS), or leave out the SOP Instance Status and associated parameters of any SOP Instances that the sending Application Entity sends out over the unsecured Transport Connection or to systems that do not support the Online Electronic Storage Secure Use Profile.</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_bbe32927-33b1-4f53-a12d-d8c95fb93df3">A receiving Application Entity that conforms to this Security Profile shall set the SOP Instance Status to Not Specified (NS) of any SOP Instance received over the unsecured Transport Connection or from systems that do not support the Online Electronic Storage Secure Use Profile.</para>
                            </listitem>
                        </orderedlist>
                    </listitem>
                    <listitem>
                        <para xml:id="para_d8b4f165-856f-4485-bf76-a3fcd61ba0d8">The receiving Application Entity shall store SOP Instances in accordance with Storage Level 2 (Full) as defined in the Storage Service Class (i.e., all Attributes, including Private Attributes), as required by the Storage Commitment Storage Service Class, and shall not coerce any Attribute other than SOP Instance Status, SOP Authorization Date and Time, Authorization Equipment Certification Number, and SOP Authorization Comment.</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_a11f3372-9c1e-4e18-a7ba-1aee39a76358">Other than changes to the SOP Instance Status, SOP Authorization Date and Time, Authorization Equipment Certification Number, and SOP Authorization Comment Attributes, as outlined above, or changes to group length Attributes to accommodate the aforementioned changes, the Application Entity shall not change any Attribute Values.</para>
                    </listitem>
                </orderedlist>
            </section>
        </section>
        <section label="A.2" status="2" xml:id="sect_A.2">
            <title>Basic Digital Signatures Secure Use Profile</title>

            <para xml:id="para_27a482bb-126e-45c2-a3ce-43be9bc636cf">An implementation that validates and generates Digital Signatures may claim conformance to the Basic Digital Signatures Secure Use Profile. Any implementation that claims conformance to this Security Profile shall obey the following rules in handling Digital Signatures:</para>
            <orderedlist numeration="loweralpha">
                <listitem>
                    <para xml:id="para_863433e2-1108-4eee-8e67-65516a32ebf2">The implementation shall store any SOP Instances that it receives in such a way that it guards against any unauthorized tampering of the SOP Instance.</para>
                </listitem>
                <listitem>
                    <para xml:id="para_6dc629cd-aa05-45ff-8ef0-772ebc030ff4">Wherever possible, the implementation shall validate the Digital Signatures within any SOP Instance that it receives.</para>
                </listitem>
                <listitem>
                    <para xml:id="para_5a52ff0b-728c-459e-a519-e027876daffa">If the implementation sends the SOP Instance to another Application Entity, it shall do the following:</para>
                    <orderedlist numeration="arabic">
                        <listitem>
                            <para xml:id="para_b2004132-f1fc-4ee4-8196-3426927adac2">remove any Digital Signatures that may have become invalid due to any allowed variations to the format of Attribute Values (e.g., trimming of padding, alternate representations of numbers),</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_20895520-7185-47aa-8978-1658abf97288">generate one or more new Digital Signatures covering the Data Elements that the implementation was able to verify when the SOP Instance was received.</para>
                        </listitem>
                    </orderedlist>
                </listitem>
            </orderedlist>
        </section>
        <section label="A.3" status="2" xml:id="sect_A.3">
            <title>Bit-preserving Digital Signatures Secure Use Profile</title>

            <para xml:id="para_c1ac99b5-ab96-4c7b-a8c2-56f6c492d9c3">An implementation that stores and forwards SOP Instances may claim conformance to the Bit-Preserving Digital Signatures Secure Use Profile. Any implementation that claims conformance to this Security Profile shall obey the following rules in handling Digital Signatures:</para>
            <orderedlist numeration="loweralpha">
                <listitem>
                    <para xml:id="para_2e7259e5-1236-4b54-bbc2-2fcf457d8a5c">The implementation shall store any SOP Instances that it receives in such a way that when the SOP instance is forwarded to another Application Entity, the Value fields of all Attributes are bit-for-bit duplicates of the fields originally received.</para>
                </listitem>
                <listitem>
                    <para xml:id="para_0b9893ef-8c15-4fbb-aded-4de314d74ae9">The implementation shall not change the order of Items in a Sequence.</para>
                </listitem>
                <listitem>
                    <para xml:id="para_ad52bef0-592b-43b9-b666-90e14e194744">The implementation shall not remove or change any Data Element of any SOP Instance that it receives when sending that SOP Instance on to another Application Entity via DICOM. This includes any Digital Signatures received.</para>
                    <note>
                        <para xml:id="para_1a1f79c3-089c-486d-b09f-669f24e0480e">Implementations may add new Data Elements that do not alter any existing Digital Signatures.</para>
                    </note>
                </listitem>
                <listitem>
                    <para xml:id="para_43987ea1-546b-4c53-a6d3-c9fe4bff6282">The implementation shall utilize an explicit VR Transfer Syntax.</para>
                    <note>
                        <para xml:id="para_a4e609d3-7b7b-4227-90cb-f3b7cd5e63e1">Implementations that cannot use an explicit VR Transfer Syntax cannot conform to this Secure Use Profile, since it may not be able to verify Digital Signatures that are received with an implicit VR Transfer Syntax.</para>
                    </note>
                </listitem>
                <listitem>
                    <para xml:id="para_a72ee7ba-f5a7-40bb-b080-edfc8591ae34">The implementation shall not change the VR of any Data Element that it receives when it transmits that object to another Application Entity.</para>
                </listitem>
            </orderedlist>
        </section>
        <section label="A.4" status="2" xml:id="sect_A.4">
            <title>Basic SR Digital Signatures Secure Use Profile</title>

            <para xml:id="para_2a5d7ffa-7a92-4e70-a19e-9c2e233cc53a">Any implementation that claims conformance to this Security Profile shall obey the following rules when creating a Structured Report or Key Object Selection Document that includes Digital Signatures:</para>
            <orderedlist numeration="loweralpha">
                <listitem>
                    <para xml:id="para_6656e4ef-2edc-477c-af26-fcc666be6a52">When the implementation signs a Structured Report or Key Object Selection Document SOP Instance the Digital Signatures shall be created in accordance with the Structured Report RSA Digital Signature Profile.</para>
                </listitem>
                <listitem>
                    <para xml:id="para_35fcdc0f-8aef-4a3a-a52c-1752ecc01d6f">In every signed Structured Report or Key Object Selection Document SOP Instance created, all referenced SOP Instances listed in the Referenced SOP Sequence Items of the Current Requested Procedure Evidence Sequence (0040,A375) and Pertinent Other Evidence Sequence (0040,A385)shall include either a Referenced Digital Signature Sequence or a Referenced SOP Instance MAC Sequence. The references may include both.</para>
                </listitem>
            </orderedlist>
            <para xml:id="para_aa2887a8-497f-4ebe-a4f2-d66c25f4cfc1">The implementation claiming conformance shall outline in its conformance statement the conditions under which it will either sign or not sign a Structured Report or Key Object Selection Document.</para>
        </section>
        <section label="A.5" status="2" xml:id="sect_A.5">
            <title>Audit Trail Message Format Profile</title>

            <para xml:id="para_c00bbfe1-bcaa-47c8-8977-051ff682d7b8">To help assure healthcare privacy and security in automated systems, usage data need to be collected. These data will be reviewed by administrative staff to verify that healthcare data is being used in accordance with the healthcare provider's data security requirements and to establish accountability for data use. This data collection and review process is called security auditing and the data itself comprises the audit trail. Audit trails can be used for surveillance purposes to detect when interesting events might be happening that warrant further investigation.</para>
            <para xml:id="para_cc8add7f-fe77-4ff1-b91c-51bbbf3c2798">This profile defines the format of the data to be collected and the minimum set of attributes to be captured by healthcare application systems for subsequent use by a review application. The data includes records of who accessed healthcare data, when, for what action, from where, and which patients' records were involved. No behavioral requirements are specified for when audit messages are generated, or for what action should be taken on their receipt. These are subject to local policy decisions and legal requirements.</para>
            <para xml:id="para_1580dcc8-550a-40aa-9d5a-1f5933702a58">Any implementation that claims conformance to this Security Profile shall:</para>
            <orderedlist numeration="loweralpha">
                <listitem>
                    <para xml:id="para_78764f1e-9af4-49fe-8596-05dfffa5d88d">format audit trail messages in accordance with the XML schema specified in <xref linkend="sect_A.5.1" xrefstyle="select: label"/> in a fashion that allows those messages to be validated against that XML schema, following the general conventions specified in <xref linkend="sect_A.5.2" xrefstyle="select: label"/>.</para>
                </listitem>
                <listitem>
                    <para xml:id="para_f29fc6f4-57c6-45d2-ab5c-c5265e0ef291">for the events described in this Profile comply with the restrictions specified by this Profile in <xref linkend="sect_A.5.3" xrefstyle="select: label"/>, and describe in its conformance statement any extensions.</para>
                    <note>
                        <para xml:id="para_703535a0-b540-40c2-88a4-580fbcd2f8ec">An implementation may include implementation-specific extensions as long as the above conditions are met.</para>
                    </note>
                </listitem>
                <listitem>
                    <para xml:id="para_72c59b7a-5bda-4335-b0de-07ffc7df01fc">describe in its conformance statement the events that it can detect and report,</para>
                </listitem>
                <listitem>
                    <para xml:id="para_8ea5ddde-0b03-48a2-bb75-767e1e48983c">describe in its conformance statement the processing it can perform upon receipt of a message</para>
                </listitem>
                <listitem>
                    <para xml:id="para_5e9ca796-cb0d-4314-8fe3-0055cf7558a4">describe in its conformance statement how event reporting and processing can be configured</para>
                </listitem>
            </orderedlist>
            <note>
                <para xml:id="para_bf8f7d1b-9fd9-469e-8997-fbdd68e51c8e">Other profiles specify the transmission of audit messages.</para>
            </note>
            <section label="A.5.1" status="3" xml:id="sect_A.5.1">
                <title>DICOM Audit Message Schema</title>
                <para xml:id="para_ab1c570c-b825-4c01-8cc7-2f5991feb846">Implementations claiming conformance to this profile shall use the following XML schema to format audit trail messages. This schema is derived from the schema specified in <xref linkend="biblio_RFC_3881"/>, according to W3C Recommendation "XML Schema Part 1: Structures," version 1.0, May 2001, and incorporates the DICOM extensions and restrictions outlined in <xref linkend="sect_A.5.2" xrefstyle="select: label"/>.</para>
                <para xml:id="para_5fad4d2b-2b02-40d1-8aa9-6b5013d39042">This schema is provided in Relax NG Compact format.</para>
                <note>
                    <para xml:id="para_f7aec1d3-858b-4a0b-af2c-d497a108517a">This schema can be converted into an equivalent XML Schema or other electronic format. It includes some modifications to the <xref linkend="biblio_RFC_3881"/> schema that reflect field experience with audit message requirements. It extends the <xref linkend="biblio_RFC_3881"/> schema.</para>
                </note>
                <section label="A.5.1.1" xml:id="sect_A.5.1.1">
                    <title>Audit Message Schema</title>
                    <para xml:id="para_64ddd571-7a1a-4582-b127-85ae11eed89a">The following is the content of the audit message schema:</para>
                    <programlisting><![CDATA[datatypes xsd = "http://www.w3.org/2001/XMLSchema-datatypes"

# This defines the coded value type. The comment shows a pattern that can be used to further
# constrain the token to limit it to the format of an OID. Not all schema software 
# implementations support the pattern option for tokens.
other-csd-attributes =
  (attribute codeSystemName { token } |     # OID pattern="[0-2]((\.0)|(\.[1-9][0-9]*))*"
     attribute codeSystemName { token }),   # This makes clear that codeSystemName is
                                            # either an OID or String 
  attribute displayName { token }?,
  attribute originalText { token }          # Note: this also corresponds to DICOM "Code Meaning"
CodedValueType =
  attribute csd-code { token },
  other-csd-attributes

# Define the event identification, used later

EventIdentificationContents =
  element EventID { CodedValueType },
  element EventTypeCode { CodedValueType }*, # Note: DICOM/IHE defines and uses this
                                             # differently than RFC 3881
  attribute EventActionCode {                # Optional action code
    "C" |              ## Create
    "R" |              ## Read
    "U" |              ## Update
    "D" |              ## Delete
    "E"                ## Execute
  }?,
  
  attribute EventDateTime { xsd:dateTime },
  attribute EventOutcomeIndicator {
    "0" |            ## Nominal Success (use if status otherwise unknown or ambiguous)
    "4" |            ## Minor failure (per reporting application definition)
    "8" |            ## Serious failure (per reporting application definition)
    "12"             ## Major failure, (reporting application now unavailable)
  },
  
  element EventOutcomeDescription { text }?
  
# Define AuditSourceIdentification, used later

AuditSourceIdentificationContents =
  attribute AuditEnterpriseSiteID { token }?,
  attribute AuditSourceID { token },
  element AuditSourceTypeCode { AuditSourceTypeCodeContent }*

# Define AuditSourceTypeCodeContent so that an isolated single digit
# value is acceptable, or a token with other csd attributes so that
# any controlled terminology can also be used.

AuditSourceTypeCodeContent = 
  attribute csd-code {
    "1" |                 ## End-user display device, diagnostic device
    "2" |                 ## Data acquisition device or instrument
    "3" |                 ## Web Server process or thread
    "4" |                 ## Application Server process or thread
    "5" |                 ## Database Server process or thread
    "6" |                 ## Security server, e.g., a domain controller
    "7" |                 ## ISO level 1-3 network component
    "8" |                 ## ISO level 4-6 operating software
    "9" |                 ## other
    token },              ## other values are allowed if a codeSystemName is present
  other-csd-attributes?  ## If these are present, they define the meaning of code
  
# Define ActiveParticipantType, used later

ActiveParticipantContents =
  element RoleIDCode { CodedValueType }*,
  element MediaIdentifier {
    element MediaType { CodedValueType }
  }?,
  attribute UserID { text },
  attribute AlternativeUserID { text }?,
  attribute UserName { text }?,
  attribute UserIsRequestor { xsd:boolean },
  attribute NetworkAccessPointID { token }?,
  attribute NetworkAccessPointTypeCode {
    "1" |              ## Machine Name, including DNS name
    "2" |              ## IP Address
    "3" |              ## Telephone Number
    "4" |              ## Email address
    "5" }?             ## URI (user directory, HTTP PUT, ftp, etc.)

# The BinaryValuePair is used in ParticipantObject descriptions to capture parameters. 
# All values (even those that are normally plain text) are encoded as xsd:base64Binary.
# This is to preserve details of encoding (e.g., nulls) and to protect against text
# contents that contain XML fragments. These are known attack points against applications,
# so security logs can be expected to need to capture them without modification by the
# audit encoding process.

ValuePair =
  # clarify the name
  attribute type { token },
  attribute value { xsd:base64Binary } # used to encode potentially binary, malformed XML text, etc.

# Define ParticipantObjectIdentification, used later

# Participant Object Description, used later

DICOMObjectDescriptionContents =
  element MPPS {
    attribute UID { token }       # OID pattern="[0-2]((\.0)|(\.[1-9][0-9]*))*"
  }*,
  element Accession {
    attribute Number { token }
  }*,
  element SOPClass {              # SOP Class for one Study
    element Instance {
      attribute UID { token }     # OID pattern="[0-2]((\.0)|(\.[1-9][0-9]*))*"
    }*,
    attribute UID { token }?,     # OID pattern="[0-2]((\.0)|(\.[1-9][0-9]*))*"
    attribute NumberOfInstances { xsd:integer }
  }*,
  element ParticipantObjectContainsStudy {
    element StudyIDs {
      attribute UID { token }
    }*
  }?,
  element Encrypted { xsd:boolean }?,
  element Anonymized { xsd:boolean }?

ParticipantObjectIdentificationContents =
  element ParticipantObjectIDTypeCode { CodedValueType },
  (element ParticipantObjectName { token } |             # either a name or
  element ParticipantObjectQuery { xsd:base64Binary }),  # a query ID field,
  element ParticipantObjectDetail { ValuePair }*,   # optional details, these can be extensive
                                                    # and large
  element ParticipantObjectDescription { DICOMObjectDescriptionContents }*,
  attribute ParticipantObjectID { token },          # mandatory ID
  attribute ParticipantObjectTypeCode {             # optional type
    "1" | ## Person
    "2" | ## System object
    "3" | ## Organization
    "4"   ## Other
  }?,
  
  attribute ParticipantObjectTypeCodeRole {          ## optional role
    "1" |         ## Patient
    "2" |         ## Location
    "3" |         ## Report
    "4" |         ## Resource
    "5" |         ## Master File
    "6" |         ## User
    "7" |         ## List
    "8" |         ## Doctor
    "9" |         ## Subscriber
    "10" |        ## Guarantor
    "11" |        ## Security User Entity
    "12" |        ## Security User Group
    "13" |        ## Security Resource
    "14" |        ## Security Granularity Definition
    "15" |        ## Provider
    "16" |        ## Data Destination
    "17" |        ## Data Archive
    "18" |        ## Schedule
    "19" |        ## Customer
    "20" |        ## Job
    "21" |        ## Job Stream
    "22" |        ## Table
    "23" |        ## Routing Criteria
    "24" |        ## Query
    "25" |        ## Data Source
    "26"          ## Processing Element
    }?,
  
  attribute ParticipantObjectDataLifeCycle {          # optional life cycle stage
    "1" |         ## Origination, Creation
    "2" |         ## Import/ Copy
    "3" |         ## Amendment
    "4" |         ## Verification
    "5" |         ## Translation
    "6" |         ## Access/Use
    "7" |         ## De-identification
    "8" |         ## Aggregation, summarization, derivation
    "9" |         ## Report
    "10" |        ## Export
    "11" |        ## Disclosure
    "12" |        ## Receipt of Disclosure
    "13" |        ## Archiving
    "14" |        ## Logical deletion
    "15" }?,      ## Permanent erasure, physical destruction
  
  attribute ParticipantObjectSensitivity { token }?
  
# The basic message
message =
  element AuditMessage {
    (element EventIdentification { EventIdentificationContents }, # The event must be identified
     element ActiveParticipant { ActiveParticipantContents }+, # It has one or more active
                                                               # participants
     element AuditSourceIdentification {                       # It is reported by one source
       AuditSourceIdentificationContents
     },
     element ParticipantObjectIdentification {                 # It may have other objects involved
       ParticipantObjectIdentificationContents
     }*)
  }

# And finally the magic statement that message is the root of everything.
start = message
]]>
    </programlisting>
                </section>
                <section label="A.5.1.2" status="4" xml:id="sect_A.5.1.2">
                    <title>Codes Used Within the Schema</title>
                    <para xml:id="para_f09dd3e1-8541-464e-b06b-3f9f6061ebca">The following value sets are defined in the audit message schema above. These are not coded terminology. They are values whose meaning depends upon their use at the proper location within the message.</para>
                    <section label="A.5.1.2.1" status="5" xml:id="sect_A.5.1.2.1">
                        <title>Audit Source Type Code</title>
                        <para xml:id="para_1cbf3fee-b911-4dd0-92fb-44ccfc9bd9ba">The Audit Source Type Code values specify the type of source where an event originated. Codes from coded terminologies and implementation defined codes can also be used for the AuditSourceTypeCode.</para>
                        <table frame="box" label="A.5.1.2.1-1" rules="all" xml:id="table_A.5.1.2.1-1">
                            <caption>Audit Source Type Code Values</caption>
                            <thead>
                                <tr valign="top">
                                    <th align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_69f1fb4b-787e-4084-b762-3bae4cd56029">Value</para>
                                    </th>
                                    <th align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_56eebc58-8b4e-4f9a-acdf-95104d17fed2">Meaning</para>
                                    </th>
                                </tr>
                            </thead>
                            <tbody>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_74f44ecb-d5e2-4afc-adff-c95a8b1d10be">1</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_e2db1f5c-3bd5-420f-a2c4-93698e784f05">End-user interface</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_39ec36d3-1134-47da-af55-16972aa8adc5">2</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_e50b156f-cd3e-4cb0-a6e6-a7fe21300d31">Data acquisition device or instrument</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_e791a463-1733-456b-8302-9f77dc0ab0a8">3</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_11efe581-9637-4136-9826-53fd939e618b">Web server process tier in a multi-tier system</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_2b2cf7ea-741f-488c-943a-198a82ddb551">4</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_11f53c60-d72a-4338-ba4a-83d321771eaa">Application server process tier in a multi-tier system</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_e116cb2a-9d28-4ea7-880c-5c1ea01adfae">5</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_aae58161-dd16-4950-b817-88dfe09746a4">Database server process tier in a multi-tier system</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_4336d8ae-60c2-4d79-b273-ac255b4267cb">6</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_a62e380c-a6ca-4ca2-8f26-f3f64eaefbb6">Security server, e.g., a domain controller</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_123fd859-cd6c-4248-9f85-6ac7d20b3249">7</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_712b0495-f637-43f0-9db6-7260a42a9743">ISO level 1-3 network component</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_07dde84a-356a-4941-8871-1369fa5eb273">8</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_97257c29-1ecd-4f0a-9a9c-3e4b7ea2b3f7">ISO level 4-6 operating software</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_4da3802e-37a5-4218-a1c9-6512243724b5">9</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_25880344-d957-4215-86d6-6e2f98e94e38">External source, other or unknown type</para>
                                    </td>
                                </tr>
                            </tbody>
                        </table>
                    </section>
                    <section label="A.5.1.2.2" status="5" xml:id="sect_A.5.1.2.2">
                        <title>Participant Object Type Code Role</title>
                        <para xml:id="para_fc99cc77-a902-4368-abc9-e6089e4da0c5">The Participant Object Type Code Role is an attribute of the ParticipantObjectIdentification, and is not extensible. This attribute may be omitted or one of the following values assigned. Coded terminologies are not supported.</para>
                        <table frame="box" label="A.5.1.2.2-1" rules="all" xml:id="table_A.5.1.2.2-1">
                            <caption>Participant Object Type Code Role Values</caption>
                            <thead>
                                <tr valign="top">
                                    <th align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_1f636b56-af4a-4be5-a3ea-7698a2095f45">Value</para>
                                    </th>
                                    <th align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_3d1d9332-b19d-470a-84ed-c057d95a6c31">Meaning</para>
                                    </th>
                                    <th align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_c070b663-a980-4578-965b-6d8e8f1f1e24">Likely associated Participant Object Type Code</para>
                                    </th>
                                </tr>
                            </thead>
                            <tbody>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_2f37dd8d-95ed-49e8-82d5-7eddd343a027">1</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_c2e78756-2ba1-468e-be61-7fd98be3625c">Patient</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_ac6e97f9-351d-4a55-ad7e-7aab14697f9a">1 - Person</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_f09a9888-b64d-42f7-b9a3-bde31ae156b6">2</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_d87487d5-87a0-4d70-8343-70cfb4c13cc6">Location</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_d6438730-af99-43fd-a627-1227f94f1e62">3 - Organization</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_6d412a83-a386-4548-bcd6-398a06984f10">3</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_09c8f9ef-d8b6-4267-b470-b2a87c1201a9">Report</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_77fe242e-bfbe-47c7-8d69-c59675ea767c">2 - System Object</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_0ec3cad8-2912-4bcf-94e8-37543e5347b1">4</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_26d95391-8966-499d-a6ea-74d2cb3fd5de">Resource</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_81cf5311-0d48-4b4a-b066-4e7e189f8be5">1 - Person, or</para>
                                        <para xml:id="para_af28f43c-f091-4f1f-bf01-05e74911615e">3 - Organization</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_7452364a-eccc-43ba-89ae-cb472620381c">5</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_a1619d48-47f2-400d-b3c2-ede4bc2aca1a">Master File</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_f670f22d-381c-4517-af11-2a8f032bc8c9">2 - System Object</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_06307f8b-1b5f-4e12-b2b8-2fde58ea52c9">6</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_4836be46-61e0-47e2-8d19-9a5a54336313">User</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_647f161b-492c-48f1-9033-3d95f56898c0">1 - Person, or</para>
                                        <para xml:id="para_1325bd2f-3e12-4640-b5b8-2e50ee0ab31b">2 - System Object</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_12180084-0e19-4ccb-b0fc-f78f0b8093e3">7</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_8eb6e79d-aa9f-423a-8896-df538cb69346">List</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_b75c51ae-1530-4a67-a83c-23497406f56d">2 - System Object</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_eb987656-744d-453b-b16c-5a65bb5f19d9">8</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_01be0a2a-ccc1-4f19-a290-8645221183c1">Doctor</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_3b046783-9415-4d8e-957e-6b9df34511c3">1 - Person</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_92866cf5-a9c7-4519-b4a9-43e15b4f0d39">9</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_527bdfb5-fb0a-44c2-bcf0-c6977792d7d2">Subscriber</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_36eda6b9-f506-4c8c-aab1-01cd076a5a7c">3 - Organization</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_b375a484-79e5-444b-9e84-a5dd524fa501">10</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_ba1dece5-b2db-4978-8092-1b115fbd195f">Guarantor</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_f3a545fa-1fec-4174-a13e-e24ef98935c3">1 - Person, or</para>
                                        <para xml:id="para_c748e666-0228-4ba9-bb33-09571967c173">3 - Organization</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_5f302b2d-8d2a-4c03-aae5-c45aa6e18f53">11</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_e0f630db-2393-4a5c-812f-4e8116a19cee">Security User Entity</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_7569f2a6-300e-48a1-ba82-199a646bbe79">1 - Person, or</para>
                                        <para xml:id="para_546f4b53-a252-4c56-86df-a89c6494922a">2 - System Object</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_2d5facf6-01c7-4093-8090-bc3e4cbc432b">12</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_44ccb03b-68b4-4d0b-9dd3-ecdf98220670">Security User Group</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_770c7458-68f6-4fc6-ad63-3be56bd9c5fd">2 - System Object</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_788d7c58-f4ea-4194-912b-adeff5f4a5f9">13</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_580153ec-c962-48e9-9569-dc20466d70c2">Security Resource</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_9ff8e7b2-1e53-44f8-af68-07ab6cc3b074">2 - System Object</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_bc8fb417-d2b7-4ecc-9bcf-1739e3927030">14</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_5f31c737-f47e-4709-bcc0-851bc29fd223">Security Granularity Definition</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_d212289f-fcde-4247-8e9a-6b68a6e2c0f9">2 - System Object</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_13174d29-3c53-403e-9ceb-23bc062c5b97">15</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_320fc0ed-3a19-4c75-bde5-b1d29d64ab09">Provider</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_4ddf2456-da72-4c2c-8dd7-9cfebc6164a6">1 - Person, or</para>
                                        <para xml:id="para_c9b258d4-416c-4d93-83ad-cd477d014c3d">3 - Organization</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_395510ef-ad3f-4e80-a7dc-50f1162d9e0b">16</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_2b93ba6d-1c22-43b9-8e25-200a2a09d1ce">Data Destination</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_4d72fd02-aa55-4a27-bf62-e84153f3416b">2 - System Object</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_6eb48014-216e-4240-8fa3-145032e2d379">17</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_5b1af86a-b867-41b7-99eb-0ed441cb818d">Data Repository</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_243c4847-12cb-487f-a7c0-ec8dfbc36082">2 - System Object</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_7dd79745-8312-4ecd-b25d-2cd998c7848c">18</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_723c18d9-e4f3-47a2-94c9-c5c1a1a5d42d">Schedule</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_c54a466a-ea10-41b9-9c1e-0f284529c393">2 - System Object</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_54bd9470-aafb-4f6b-b0e2-f6d72ffa3f23">19</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_8aaab0c7-ddbc-45d5-9d38-9555e998efb6">Customer</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_0e561697-e2d8-42a4-8c67-d8d37d2d8b41">3 - Organization</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_675176e9-da93-4bf3-b890-45dccecbc7af">20</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_df57c7c2-42d7-4449-9bfd-1853abe7b05e">Job</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_abff914c-550f-44db-9fc3-6ce4142e4ca9">2 - System Object</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_87c83dd6-9ff3-495a-af7a-8f78afc5ef85">21</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_d81f01a2-38f4-4b0b-92ab-1edafb48d8e1">Job Stream</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_9eed2cd8-a0f9-4613-9c67-3c868595916f">2 - System Object</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_0259bd57-2294-4098-bc54-db5dcaaf839a">22</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_e653d221-8213-46db-b278-99cccaf99ef0">Table</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_e46ccac8-e53c-4de0-aea0-3d1eaf1e92cc">2 - System Object</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_08eaf71e-e8d0-4947-b7c7-f89681d0cfa4">23</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_d559c880-3c4e-488f-8ad5-daf429c733e2">Routing Criteria</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_83117a26-1197-497a-b756-0a4cae5d0a4c">2 - System Object</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_1fe4b192-e020-4af8-be15-5e28ea4ad67a">24</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_f03195d2-f445-4e9c-9b3d-3b320c110c25">Query</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_7d4692ce-1616-458a-8280-0cc1f979be7a">2 - System Object</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_3dd5667a-e969-4f2e-81b1-54f71f23930f">25</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_3cfacfcb-bb34-48b7-a3b3-63856e84201f">Data Source</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_7bb8acb9-80ee-4a41-bfe2-72f979958117">2 - System Object</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_aa9ea40f-956d-4389-883a-9645e454ea21">26</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_33af07de-e8d5-4749-ad15-bbabfeccf245">Processing Element</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_609874fd-85c2-41d3-8657-5880564d1e0d">2 - System Object</para>
                                    </td>
                                </tr>
                            </tbody>
                        </table>
                    </section>
                    <section label="A.5.1.2.3" status="5" xml:id="sect_A.5.1.2.3">
                        <title>Participant Object Data Life Cycle</title>
                        <para xml:id="para_1b4865b0-5b56-4d6a-b3dc-68ac99b3876e">The Participant Object Data Life Cycle is an attribute of the ParticipantObjectIdentification, and is not extensible. This attribute may be omitted or one of the following values assigned. Coded terminologies are not supported.</para>
                        <table frame="box" label="A.5.1.2.3-1" rules="all" xml:id="table_A.5.1.2.3-1">
                            <caption>Participant Object Data Life Cycle Values</caption>
                            <thead>
                                <tr valign="top">
                                    <th align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_d0e1c681-04c0-4149-ad2e-5a3ce70c8d63">Value</para>
                                    </th>
                                    <th align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_aea7e5e9-4c1d-415b-8193-d5fac95e2ecd">Meaning</para>
                                    </th>
                                </tr>
                            </thead>
                            <tbody>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_dbf72428-126c-4b99-97c7-0aa7cb9deae4">1</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_cfa082f4-4567-431d-8672-acd19070f29c">Origination or Creation</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_33671728-8a6c-422b-b829-9805bf43eeae">2</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_e3558a04-f2dd-4614-9849-e396a4ab7af0">Import or Copy from original</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_ed330a2a-c277-4ff8-92eb-accd944343bd">3</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_b51893d7-20f4-4add-b08b-fd2c65b02abe">Amendment</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_dcc18acf-4fd3-4689-afb0-72c51af454f4">4</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_67f4d349-6404-4db4-b317-1171260e45df">Verification</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_516670b6-f3b7-4062-bccd-c2bcba381dbd">5</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_69093639-a385-45f6-a2a7-bcc38100647d">Translation</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_70a8d24a-885a-458b-8bad-f50d2ec9cdf2">6</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_6d88264e-dd04-4a99-8974-1105b400a9e0">Access or Use</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_0ef5eaa6-2f3a-4833-a115-137d1c7e063e">7</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_2ab683f3-fb07-4c11-a76d-b6ed2ef79aa4">De-identification</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_59ddefe3-07d1-4efd-b72b-56ee0402c922">8</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_5bf109e6-ba45-47c2-9674-08dc6eadc8c4">Aggregation, summarization, derivation</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_2ade4960-8f78-4b91-80a1-50d99d9c490c">9</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_7a15094e-32b2-44d7-8900-0a1edb4b0faf">Report</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_128629bc-fedc-45a8-84e2-8da90cd60009">10</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_d94f016e-d318-4311-b4e6-5012d99c7fac">Export or Copy to target</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_69c9b218-a35d-4fc1-a3f7-892c9c979ce6">11</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_26f4f51d-5678-444f-830c-4652742bb847">Disclosure</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_0119dfc9-204e-4512-a7c7-018c125204fe">12</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_2ad42994-c18c-4aee-848b-3949010cc664">Receipt of Disclosure</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_17bf919c-da84-4935-8f51-2c2133666bd4">13</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_63d34f50-4c3e-4115-9bd1-415f3d275c00">Archiving</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_9b1eb515-4520-491e-b8d1-aa065df5068c">14</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_e2c7d00a-aef4-4ac0-8766-d8ae240d8ee0">Logical Deletion</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_77f8aa7e-e2ff-4804-a13d-3a0ea747141f">15</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_f541d3b0-d0c7-4a84-a02a-c5421af3e459">Permanent erasure or physical destruction</para>
                                    </td>
                                </tr>
                            </tbody>
                        </table>
                    </section>
                    <section label="A.5.1.2.4" status="5" xml:id="sect_A.5.1.2.4">
                        <title>Participant Object ID Type Code</title>
                        <para xml:id="para_03c7c27b-c253-4379-a2dc-33ee0bd9021f">The Participant Object ID Type Code describes the identifier that is contained in Participant Object ID. Codes from coded terminologies and implementation defined codes can also be used for the ParticipantObjectTypeCodeRole.</para>
                        <table frame="box" label="A.5.1.2.4-1" rules="all" xml:id="table_A.5.1.2.4-1">
                            <caption>Participant Object ID Type Code Values</caption>
                            <thead>
                                <tr valign="top">
                                    <th align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_c78e8677-47fb-48b9-9718-dae6b263598d">Value</para>
                                    </th>
                                    <th align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_80010d0f-3e02-42f0-a1e6-86a26ce29feb">Meaning</para>
                                    </th>
                                    <th align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_505838a4-747a-4382-a057-318b9684c312">Likely associated Participant Object Type Code</para>
                                    </th>
                                </tr>
                            </thead>
                            <tbody>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_11ecfcdc-8fe0-415c-ad17-bf8462aa8571">1</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_0605cfd3-7670-4ef5-afbb-7f3d9fb6657b">Medical Record Number</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_bb256caf-05fe-4bba-afe1-905c410bcaf2">1 - Person</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_5cc42d29-7c94-4782-8f9c-717691126e4b">2</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_7a6ded6b-089a-406a-8b56-4e9601d79fbf">Patient Number</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_ae37cfde-eb5a-412f-840d-d6d5cb06d0e9">1 - Person</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_86729e26-ed4b-425d-a711-4193c460415b">3</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_bfb0a104-752c-4b9a-bfe3-9e713cdc8d66">Encounter Number</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_824b95c9-c8a1-44a8-974f-0c7d5f5e31e7">1 - Person</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_cfe80e63-a0cd-4185-99f8-c7cf003aecfa">4</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_9f2cdb6e-18b1-4924-b188-eaeb3d3e3f25">Enrollee Number</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_d26a9d42-7410-4eb5-ae92-9c679bba1f67">1 - Person</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_415b7983-2190-49b2-bbdb-f06aa77232c4">5</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_31d2b1df-77fe-46a0-a267-d483ceaa69e5">Social Security Number</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_c20ebfdc-462b-4cf5-9202-fa5cd1f6bb1b">1 - Person</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_809c9e6d-0e5e-4813-95c7-750aed801f2a">6</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_269ed1fb-92df-4a87-afd9-e272b95bbb1c">Account Number</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_b41e25ac-2304-4d18-b544-209e4da81de8">1 - Person, or</para>
                                        <para xml:id="para_2cc04e39-1db9-42a4-b390-4d9828e31402">3 - Organization</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_70a347c3-0e80-464f-9047-b3fd96b6d4f7">7</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_d499a167-eec1-4d14-9d9a-aad8b0a94586">Guarantor Number</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_242a0e7b-cd8a-4d37-9d3e-ab327938227a">1 - Person, or</para>
                                        <para xml:id="para_105be10b-9f6c-44f5-be88-4fc01974769f">3 - Organization</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_582782e4-8f75-4a90-995b-405a6a4e9ff6">8</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_8b59f82b-a96d-4bb8-aa24-15a03c310baf">Report Name</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_f500eb72-f51b-4a27-863f-85884d5a7e0f">2 - System Object</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_4914c095-6ac4-4fb0-8cdf-4b026c096673">9</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_d877e121-fc0c-47e1-a5e7-10603a3dd772">Report Number</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_b3770bcd-b13a-46d0-bdea-f945e9248c84">2 - System Object</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_58902f34-b20f-4a27-b4f2-dab02d51e73f">10</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_56242809-444e-4193-894c-548dbd48d617">Search Criteria</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_572ddd04-363e-41ed-8508-c02f2d8e60da">2 - System Object</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_a2ce74a6-31bb-4680-a5b6-a9be9cd1b50a">11</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_dd4982a9-5348-4f81-bed0-20cf4d421cd4">User Identifier</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_4b7f5513-f13d-4aaa-bc6c-14d055f6a358">1 - Person, or</para>
                                        <para xml:id="para_43b19106-c958-4e0d-9ae1-1b2aebe4d025">2 - System Object</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_8d510752-5eff-43e3-9231-a54a80863898">12</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_a194ff9e-0eb1-46fd-bf00-9803ac2544a0">URI</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_b6f649e1-a574-4df4-80c8-659faf6e07fa">2 - System Object</para>
                                    </td>
                                </tr>
                            </tbody>
                        </table>
                    </section>
                    <section label="A.5.1.2.5" status="5" xml:id="sect_A.5.1.2.5">
                        <title>Network Access Point Type Code</title>
                        <para xml:id="para_e906bb6d-2b79-4e2e-97de-894cdd017e42">The Network Access Point Type Code describes the identifier that is contained in NetworkAccessPointID, and is not extensible. Coded terminologies are not supported.</para>
                        <table frame="box" label="A.5.1.2.5-1" rules="all" xml:id="table_A.5.1.2.5-1">
                            <caption>Network Access Point Type Code Values</caption>
                            <thead>
                                <tr valign="top">
                                    <th align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_24c66e7b-3923-4bbd-87c3-a403c16bc4bb">Value</para>
                                    </th>
                                    <th align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_7a26ff42-6d51-4fab-a910-572dabb1bb9e">Meaning</para>
                                    </th>
                                </tr>
                            </thead>
                            <tbody>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_3c3babd6-7862-4721-903b-8bbdcb059376">1</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_62055a28-42fe-4c96-9004-a6738261a3ed">Machine Name, including DNS name</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_8bf0530c-4136-46f2-9d25-3c8366958b69">2</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_3ee4c895-ebd1-4ee9-89d2-ececb6569906">IP Address</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_62c5c3cf-f447-403d-afa4-2d79e1fc9564">3</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_ba44b1e6-9cf1-46e1-a027-fd4b95b542e6">Telephone Number</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_8b65bd04-cc9c-4f19-afcc-659bb0dae588">4</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_d12378d0-ff35-45ba-85eb-0f9f37c9e67c">Email address</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_39bb71b8-04b5-49b8-9901-8b99bd775259">5</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_276db350-ca09-404d-a8b5-6d3ac673555a">URI (user directory, HTTP PUT, ftp, etc.)</para>
                                    </td>
                                </tr>
                            </tbody>
                        </table>
                    </section>
                </section>
            </section>
            <section label="A.5.2" status="3" xml:id="sect_A.5.2">
                <title>General Message Format Conventions</title>
                <para xml:id="para_4764a4fc-01bc-48ba-921b-fd7eb84abf41">The following table lists the primary fields from the DICOM Audit Message Schema specified in <xref linkend="sect_A.5.1" xrefstyle="select: label"/>, with additional instructions, conventions, and restrictions on how DICOM applications shall fill in the field values. The field names are leaf elements and attributes that are in the schema. Note that these fields may be enclosed in other XML elements, as specified by the schema.</para>
                <note>
                    <para xml:id="para_4139839c-db23-401d-a650-9fd7d94615d0">This schema, codes, and content were originally derived from <xref linkend="biblio_RFC_3881"/>. <xref linkend="biblio_RFC_3881"/> is not being maintained or updated by the IETF, and has gradually diverged from the DICOM schema and codes. Other documents exist that refer to <xref linkend="biblio_RFC_3881"/> as the underlying standard. <xref linkend="biblio_RFC_3881"/> does not include corrections and additions to the audit message schema made in DICOM since 2004.</para>
                </note>
                <para xml:id="para_5ff19a32-fb8b-4b3a-9e04-1845333929c6">Although XML permits empty elements and attributes with a value of the empty string, Audit Messages shall not contain empty elements and shall not contain attributes with a value of the empty string.</para>
                <para xml:id="para_dd19b47b-01e3-47ad-ad33-49e992412a89">In subsequent tables the following notation is used for optionality:</para>
                <variablelist>
                    <varlistentry>
                        <term>M</term>
                        <listitem>
                            <para xml:id="para_634e71c9-2490-40e8-882e-c7bbebd1e445">This element or attribute is mandatory</para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>U</term>
                        <listitem>
                            <para xml:id="para_31308398-8253-40fc-82dd-d4bea3944ed2">This element or attribute is user optional. The creator may include it or omit it.</para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>MC</term>
                        <listitem>
                            <para xml:id="para_19b93d19-6b06-4073-af48-73afc82f1440">This element or attribute is mandatory if a specified condition is true.</para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>UC</term>
                        <listitem>
                            <para xml:id="para_0f45c097-3333-4047-b471-79d9cc45c27f">This element or attribute may be present only if a specified condition is true, if the user chooses to include it.</para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="A.5.2-1" rules="all" xml:id="table_A.5.2-1">
                    <caption>General Message Format</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1"/>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f50cd26e-e929-4bd8-bf03-c6859e6e3965">Field Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7b784edc-c9ff-4321-a2fd-3dc819196755">Opt.</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0a3d7c06-c980-4040-b2cf-3fb4a82d1b19">Description</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_84ced2d9-55b1-4047-b30f-d18bd104c3d5">Additional Conditions on Field Format/Value</para>
                            </th>
                        </tr>

                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="5">
                                <para xml:id="para_7f7eec29-3077-4ce0-b779-ff2058231bbe">Event</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_db3ad5e7-734a-49b7-b101-a4d6017d1b09">EventID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c88dcaf9-23cd-49fa-b735-4f7e85edc173">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_527c2e77-f638-46de-8e9b-5ed253cd7c5c">Identifier for a specific audited event.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4e57964-8ff2-48f2-ba57-da144e409a89">The identifier for the family of event. E.g., "User Authentication".</para>
                                <para xml:id="para_b3073941-834e-404e-94fa-f8036e10f924">D<olink targetdoc="PS3.16" targetptr="sect_CID_400" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00da466f-ebf2-4e7d-ae49-a63ba62d4bee">EventActionCode</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ef8e53d3-599f-4ab2-ab2a-e1c168d56ed3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70b3b9bf-15f3-4ca7-b6b6-841d5320d345">Indicator for type of action performed during the event that generated the audit.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3ea961cc-29ae-4e22-b7d8-5f96bdf751b0">
                                    <variablelist spacing="compact">
                                        <varlistentry>
                                            <term>C</term>
                                            <listitem>
                                                <para xml:id="para_a57bb73c-bca7-4309-8580-19d6e7d5d14c">Create a new database object, such as Placing an Order</para>
                                            </listitem>
                                        </varlistentry>
                                        <varlistentry>
                                            <term>R</term>
                                            <listitem>
                                                <para xml:id="para_190046a1-7333-4dbf-8c19-fac5f1afe41f">Read/View/Print/Query Display or print data, such as a Doctor Census</para>
                                            </listitem>
                                        </varlistentry>
                                        <varlistentry>
                                            <term>U</term>
                                            <listitem>
                                                <para xml:id="para_e210e59b-97d8-4015-b68c-5189617f9501">Update data, such as Revise Patient Information</para>
                                            </listitem>
                                        </varlistentry>
                                        <varlistentry>
                                            <term>D</term>
                                            <listitem>
                                                <para xml:id="para_8f60eb06-67da-428e-9c93-92afc64a6547">Delete items, such as a master file record</para>
                                            </listitem>
                                        </varlistentry>
                                        <varlistentry>
                                            <term>E</term>
                                            <listitem>
                                                <para xml:id="para_96832d09-563c-4680-9a84-d465059cd82d">Execute a system or application function such as log-on, program execution, or use of an object's method</para>
                                            </listitem>
                                        </varlistentry>
                                    </variablelist>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8702b14c-f50f-45f0-b134-518d674a7e33">EventDateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_abfbae00-1eb8-45cc-9e5f-d7b6bf293bb6">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ca12292-2392-4549-865b-d29f5ca6295a">Universal coordinated time (UTC), i.e., a date/time specification that is unambiguous as to local time zones.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e60b9c1-b572-4cbf-8998-e25a63e751ec">The time at which the audited event occurred.See <xref linkend="sect_A.5.2.5" xrefstyle="select: label"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da3ce126-ed75-4577-8fa0-8bc58efab0bd">EventOutcomeIndicator</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c3707a09-45c1-4b17-bdb0-345b5dbc0032">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_297f815e-7db6-4960-8999-2ecaf6eb2a98">Indicates whether the event succeeded or failed.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7393636-6f89-4b69-8103-29d4d29d9873">
                                    <variablelist spacing="compact">
                                        <varlistentry>
                                            <term>0</term>
                                            <listitem>
                                                <para xml:id="para_c3a60334-b7f6-490f-932a-3c00f8f1efa3">Success</para>
                                            </listitem>
                                        </varlistentry>
                                        <varlistentry>
                                            <term>4</term>
                                            <listitem>
                                                <para xml:id="para_8265ed6e-85dd-4547-8562-df3a9a78114a">Minor failure; action restarted, e.g., invalid password with first retry</para>
                                            </listitem>
                                        </varlistentry>
                                        <varlistentry>
                                            <term>8</term>
                                            <listitem>
                                                <para xml:id="para_720aacd7-41f5-4be3-85e5-0be51dc7a344">Serious failure; action terminated, e.g., invalid password with excess retries</para>
                                            </listitem>
                                        </varlistentry>
                                        <varlistentry>
                                            <term>12</term>
                                            <listitem>
                                                <para xml:id="para_2c73f1e8-82b4-4085-a300-1a2355534a23">Major failure; action made unavailable, e.g., user account disabled due to excessive invalid log-on attempts</para>
                                            </listitem>
                                        </varlistentry>
                                    </variablelist>
                                </para>
                                <para xml:id="para_479d1fb0-68fe-49e5-9760-615a4f16b278">When a particular event has some aspects that succeeded and some that failed, then one message shall be generated for successful actions and one message for the failed actions (i.e., not a single message with mixed results).</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4bad9146-33bc-490e-a883-2aa1238f692c">EventTypeCode</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1214b70b-ac4b-4e05-8625-014f0875092e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3dec6f8-1af5-44db-b74c-70c23a17e942">Identifier for the category of event.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ff51559-4e5a-4861-b539-74f0f77cf8d0">The specific type(s) within the family applicable to the event, e.g., "User Login".</para>
                                <para xml:id="para_c8fd2466-a658-49e8-956e-4bdb112ed6cf">D<olink targetdoc="PS3.16" targetptr="sect_CID_401" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="7">
                                <para xml:id="para_4c2d9d6c-f55f-4488-b5ea-c784777ff6b4">Active Participant (multi-valued)</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_532d783e-996b-46f5-ab84-dc0a0d21db33">UserID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_59f311c6-84c6-49ec-9ca3-f70f93813c72">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_220b51c9-60a0-47cc-a7ed-edb810ae00c7">Unique identifier for the user actively participating in the event.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_44aab9fe-4214-4685-bcba-f0e5e75a3529">See <xref linkend="sect_A.5.2.1" xrefstyle="select: label"/>.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_688d5798-b223-4ccd-834d-809d07331e66">AlternativeUserID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f793c6a-68b9-4057-a4b4-3fbc39588928">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_949ba071-1644-4f93-9055-886809d13c3c">Alternative unique identifier for the user.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8bbf337c-6f6d-4306-b167-74aebe669334">See <xref linkend="sect_A.5.2.2" xrefstyle="select: label"/>.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f86fdfdc-0ad1-4b25-b414-c40cdbc9de97">UserName</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b1ce24d1-493c-4969-baee-a6a60ad39f33">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9cbb4fd1-93ff-40b8-8712-e53ec0f82f15">The human-meaningful name for the user.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd3c2805-f165-4976-9484-cbf0a8572466">See <xref linkend="sect_A.5.2.3" xrefstyle="select: label"/>.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96670693-7129-489a-9618-c2bac09fe63e">UserIsRequestor</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_54eeeb40-60a1-4a1c-9750-7c9f0d77f7d5">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e99d13e-3ad6-4898-a441-241ca87cae95">Indicator that the user is or is not the requestor, or initiator, for the event being audited.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59f78965-ac13-48eb-b895-3c88b0a26581">Used to identify which of the participants initiated the transaction being audited. If the audit source cannot determine which of the participants is the requestor, then the field shall be present with the value false in all participants.</para>
                                <para xml:id="para_ef80cded-b032-4ffa-86c9-f241f7328740">The system shall not identify multiple participants as UserIsRequestor. If there are several known requestors, the reporting system shall pick only one as UserIsRequestor.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ca0ce87-5be0-4a38-b5fb-c7443662bb1f">RoleIDCode</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_95c4ca2f-8cad-4cb3-ba22-6703363405db">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c49195d4-04ca-4e4e-95ce-d421be2abecb">Specification of the role(s) the user plays when performing the event, as assigned in role-based access control security.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1985aff5-244e-4590-92d7-c75a1a973ca1">D<olink targetdoc="PS3.16" targetptr="sect_CID_402" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <note>
                                    <para xml:id="para_92cee170-01e2-4db0-b1fd-8f14bd54edb6">Usage of this field is refined in the individual message descriptions below. Other additional roles may also be present, since this is a multi-valued field.</para>
                                </note>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_416158ba-d94d-4af1-a25e-2b5a18e6f235">NetworkAccessPointTypeCode</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e002d700-67ab-49ee-af2e-cb38b4dc80f1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f3c64f5-d3ce-40a1-bac5-61afdd84e245">An identifier for the type of network access point.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9032548b-51dc-4ce9-b0f9-543669b6b167">See <xref linkend="sect_A.5.1.2.5" xrefstyle="select: label"/> for codes and <xref linkend="sect_A.5.2.4" xrefstyle="select: label"/> for further details.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30cf6dc2-49d1-4792-b03b-30222700060b">NetworkAccessPointID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e921a06b-e7c3-42a8-b0d1-cf63115a574e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c58a5044-8be1-48ba-a17d-571954a58f42">An identifier for the network access point of the user device This could be a device id, IP address, or some other identifier associated with a device.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_650ce3d9-90ff-41d8-8cc2-ea48f9f16f82">See <xref linkend="sect_A.5.2.4" xrefstyle="select: label"/> for further details.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="3">
                                <para xml:id="para_2086c72a-ea92-433a-8f35-1e1ad5624229">Audit Source</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a56cc657-5a3c-401f-a1a4-93352433faf7">AuditEnterpriseSiteID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0d4813d4-75d5-4de0-9762-f1884d38ec7e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c3af334-6433-45b1-b441-34f1c9ce2a1a">Logical source location within the healthcare enterprise network, e.g., a hospital or other provider location within a multi-entity provider group.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9bb86700-1e78-467a-a8cd-1582f434115e">Serves to further qualify the Audit Source ID, since Audit Source ID is not required to be globally unique.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22dd2c94-e388-4008-82d7-bfa567eb9160">AuditSourceID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b3c922b6-116a-435b-8e66-cb3444a36469">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f978c2e6-bcba-4666-b459-63ede2f54577">Identifier of the source.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_44145990-6299-471a-98d4-ac03ff73f9af">The identification of the system that detected the auditable event and created this audit message. Although often the audit source is one of the participants, it could also be an external system that is monitoring the activities of the participants (e.g., an add-on audit-generating device).</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9499d699-2d76-4147-9d67-f5036939f202">AuditSourceTypeCode</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_47d13ea7-06d4-4fe9-8943-e830a3fe4ddd">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3af1282e-57c5-47c8-a6b6-6825fb5dbe80">Code specifying the type of source.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c9733d9-8d2b-4ca6-8e68-aa9be47e2866">See <xref linkend="sect_A.5.1.2.1" xrefstyle="select: label"/>.</para>
                                <para xml:id="para_2531abb4-bd0a-4350-bfd4-f6e82c1c1ccf">E.g., an acquisition device might use "2" (data acquisition device), a PACS/RIS system might use "4 "(application server process).</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="17">
                                <para xml:id="para_6b158fa4-7268-4a2c-b643-7ff652c493e5">Participant Object (multi-valued)</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_46a30de3-a00b-4507-8920-f59d1da08105">ParticipantObjectTypeCode</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ef5b8bff-9ba6-4e38-bf5e-d498de96d596">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_453d51b5-f6f2-4d08-a97a-f152e9694f50">Code for the participant object type being audited. This value is distinct from the user's role or any user relationship to the Participant Object.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a75ad85-3cda-47aa-9ed0-781b6d106313">
                                    <variablelist spacing="compact">
                                        <varlistentry>
                                            <term>1</term>
                                            <listitem>
                                                <para xml:id="para_b6913d57-7b79-4909-abd6-9ab58480aa8b">Person</para>
                                            </listitem>
                                        </varlistentry>
                                        <varlistentry>
                                            <term>2</term>
                                            <listitem>
                                                <para xml:id="para_dcb2f459-2c6e-43d5-8dd2-eb89e593fad8">System Object</para>
                                            </listitem>
                                        </varlistentry>
                                        <varlistentry>
                                            <term>3</term>
                                            <listitem>
                                                <para xml:id="para_ca428a79-2893-4731-9db4-6241f6a2cc27">Organization</para>
                                            </listitem>
                                        </varlistentry>
                                        <varlistentry>
                                            <term>4</term>
                                            <listitem>
                                                <para xml:id="para_6fa8a030-bcbf-4b36-b8cb-41c344ffecd3">Other</para>
                                            </listitem>
                                        </varlistentry>
                                    </variablelist>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc2f8dbb-5643-492f-ace7-1f186b88c389">ParticipantObjectTypeCodeRole</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cc62814b-dd02-4e2d-b63f-9df701740d5e">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36cd0006-1dd5-4380-9bea-6f62a8757134">Code representing the functional application role of Participant Object being audited.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0de1edf-ad90-444e-b5df-26331e013397">See <xref linkend="sect_A.5.1.2.2" xrefstyle="select: label"/>.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_542bf07b-238d-4261-bc49-8a7468f4be12">ParticipantObjectDataLifeCycle</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f91e6d39-b30f-44c7-9704-7cb4edc311fe">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5330b033-3791-4ad1-a449-daf348c2e1f1">Identifier for the data life-cycle stage for the Participant Object. This can be used to provide an audit trail for data, over time, as it passes through the system.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3116a5d7-6ad1-4639-b205-59608a8f9ed1">See <xref linkend="sect_A.5.1.2.3" xrefstyle="select: label"/>.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d43d73e0-8118-46f8-8339-753b4f9fef42">ParticipantObjectIDTypeCode</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e650982c-d8ad-48c1-b19c-08b076090c0c">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29d33046-fed7-44a6-bb40-acb07a3ff8da">Describes the identifier that is contained in ParticipantObjectID.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3084b452-694e-4830-b803-1e22f4b7704f">See <xref linkend="sect_A.5.1.2.4" xrefstyle="select: label"/> and <olink targetdoc="PS3.16" targetptr="sect_CID_404" xrefstyle="select: labelnumber quotedtitle"/>
                                </para>
                                <note>
                                    <para xml:id="para_58abe1ba-2824-452f-85a8-c831c67168c9">Usage of this field is refined in the individual message descriptions below. Multiple roles may also be present, since this is a multi-valued field.</para>
                                </note>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_76146d6d-e283-4e99-885a-683d7fb434d5">ParticipantObjectSensitivity</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c6bcf165-6ed1-4a5d-8c2b-f3aab8a5a7da">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5a40829-24e6-4064-9026-2d88eb8a503c">Denotes policy-defined sensitivity for the ParticipantObjectID such as VIP, HIV status, mental health status, or similar topics.</para>
                                <para xml:id="para_a05d9bc8-0171-400d-8592-5a7ada82aa78">This may be influenced by values in the Sensitive Content Code Sequence (0008,001D) if present in the participant object.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e36acc7d-1062-42f7-a1d0-5cafa1898f07">Locally defined terms.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c312a956-498b-4a22-8a43-2307856c14bb">ParticipantObjectID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9b0ed094-f199-4923-8c77-3acd9e212480">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8411c7ca-0109-44d7-834f-f88436aeaace">Identifies a specific instance of the Participant Object.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_441b3106-b9fe-4259-bd37-fe6044809f7c">Usage refined by individual message descriptions</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_49b88e9e-2ac7-4860-8cce-60678e5d9805">ParticipantObjectName</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d2fb1e23-47d0-4938-b84b-5b8fa327667e">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3990fcd-d954-4345-88c5-913618d45892">An instance-specific descriptor of the ParticipantObjectID audited, such as a person's name.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3581154-84cc-4db1-9f29-d643c9c99f93">Required if ParticipantObjectQuery is not present.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08917a5c-3a97-4465-b13a-a9acd611dbf4">ParticipantObjectQuery</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b17c5038-65e7-4187-addc-df30e6ea8440">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d30f4aab-1f78-4598-82f0-853c76d6d0e6">The actual query for a query-type participant object.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c531cc2e-b8a2-4208-8406-8a0fe79aef43">Required if ParticipantObjectName is not present.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a3b63b5-fd3e-42f1-812c-fb9a9dbc1b83">ParticipantObjectDetail</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8762e31a-4ce8-4e1e-bf3a-a20ae904f5ad">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5ee031c-014a-41e8-83d0-cb2e32c218a6">Implementation-defined data about specific details of the object accessed or used.</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd2ecc89-3bf7-47ef-8479-43e18d375ca8"/>
                                <para xml:id="para_41e8307b-f970-4e0b-9821-a76559d28c42">This element is a type-value pair. The "type" attribute is an implementation-defined text string. The "value" attribute is base 64 encoded data. The value is suitable for conveying binary data.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7a69c211-2c13-4416-86a8-f97e8d5d1304">SOPClass</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_735dfdc8-065e-4189-baea-c8eee94c07e0">MC</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2c055e43-efbf-4ea5-86d9-92b0bedca859"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e90d1cee-0915-4868-a69e-98cb49b2dfb9">The UIDs of SOP Classes referred to in this Participant Object.</para>
                                <para xml:id="para_e6b380c3-3ff7-470d-8c99-5fecee51fe2d">Required if ParticipantObjectIDTypeCode is <olink targetdoc="PS3.16" targetptr="DCM_110180">(110180, DCM, "Study Instance UID")</olink> and any of the optional fields (Accession, MPPS, NumberOfInstances, Instance, Encrypted, Anonymized) are present in this Participant Object. May be present if ParticipantObjectIDTypeCode is <olink targetdoc="PS3.16" targetptr="DCM_110180">(110180, DCM, "Study Instance UID")</olink> even though none of the optional fields are present.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7dec2a2b-fd91-4d4e-b7ab-6b9120d10d55">Accession</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6aeaf8e9-4423-47e5-a195-8b2263c7baf2">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e45ca9bd-2df1-441a-bb7c-3b9398a4e1d1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_12b11f80-7ff2-430f-89a4-7dc46c5b5f59">Accession Number(s) associated with this Participant Object.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_588fc1d9-c8b3-42da-8799-4c29275edd89">MPPS</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_384e4ab4-2331-4b1a-8a86-2414b26172c1">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8d4e77ca-482b-44d4-80ee-c39c74496ccf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c4a6c3e-317c-40c2-864a-03280946affc">MPPS Instance UID(s) associated with this Participant Object.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1367d36-fbd3-498f-9fb8-6387a5449019">NumberOfInstances</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_db4eb9bb-c8f5-414e-9cd9-7e9f0df91ca4">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fee41b78-d1e5-428a-887e-5e27187bf40c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dccfe881-a71b-44dd-8512-ee53a31a67ab">The number of SOP Instances referred to by this Participant Object.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7cc2d323-d3e8-4a18-b90d-7b13533d62ca">Instance</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_52f782e1-1120-488d-9823-3d37b201eea8">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_044979e4-0085-412f-8eb2-8c2e3ffe8a5e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d365512-5c81-4713-becf-8bf253d00848">SOP Instance UID value(s)</para>
                                <note>
                                    <para xml:id="para_18bd5f0b-7f2f-4dd6-8a31-d7ffdbe73365">Including the list of SOP Instances can create a fairly large audit message. Under most circumstances, the list of SOP Instance UIDs is not needed for audit purposes.</para>
                                </note>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2be7a081-6c87-4abe-b7fa-6584722f2af1">Encrypted</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8fbe630a-baf2-45d8-af57-28cc6a961afe">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_18e22efd-24ae-44d5-874f-6033c731dd01"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_790b6ac7-2db5-4bec-b9e9-294b6d58e69a">A single value of true or false indicating whether or not the data was encrypted.</para>
                                <note>
                                    <para xml:id="para_2a0009c5-ddf4-458d-becb-7e35fceea373">If there was a mix of encrypted and non-encrypted data, then create two event reports.</para>
                                </note>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_963a59c5-e10e-4909-902a-722c2f631182">Anonymized</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_32c90e85-5f5b-4ef5-9d20-a1d21c822684">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ce7b1ea-6ec9-4a77-991c-938969027a7d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dda76d79-3497-4245-b5d1-3fd9a4fde535">A single value of true or false indicating whether or not all patient identifying information was removed from the data</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7c5b2f40-ffd7-44a3-8546-32df0ba9c6c5">ParticipantObjectContainsStudy</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9808065e-55b6-4fc7-996a-a84a05f23ea1">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f588619d-610d-4ae5-893f-c38ef0b55e46"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9fabd86-00df-4871-9e0d-721bd62f990e">A Study Instance UID that may be used when the ParticipantObjectIDTypeCode is not <olink targetdoc="PS3.16" targetptr="DCM_110180">(110180, DCM, "Study Instance UID")</olink>.</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <section label="A.5.2.1" status="4" xml:id="sect_A.5.2.1">
                    <title>UserID</title>
                    <para xml:id="para_66a88433-eb1c-4f61-ba45-ec52c4251afb">If the participant is a person, then the User ID shall be the identifier used for that person on this particular system, in the form of loginName@domain-name.</para>
                    <para xml:id="para_a9854eb8-a3a1-4583-9094-358f899d4ef2">If the participant is an identifiable process, the UserID selected shall be one of the identifiers used in the internal system logs. For example, the User ID may be the process ID as used within the local operating system in the local system logs. If the participant is a node, then User ID may be the node name assigned by the system administrator. Other participants such as threads, relocatable processes, web service end-points, web server dispatchable threads, etc., will have an appropriate identifier. The implementation shall document in the Conformance Statement the identifiers used. The purpose of this requirement is to allow matching of the audit log identifiers with internal system logs on the reporting systems.</para>
                    <para xml:id="para_f79205fb-3c37-4814-935f-5aa129274796">When importing or exporting data, e.g., by means of media, the UserID field is used both to identify people and to identify the media itself. When the Role ID Code is EV <olink targetdoc="PS3.16" targetptr="DCM_110154">(110154, DCM, "Destination Media")</olink> or EV <olink targetdoc="PS3.16" targetptr="DCM_110155">(110155, DCM, "Source Media")</olink>, the UserID may be:</para>
                    <orderedlist numeration="loweralpha">
                        <listitem>
                            <para xml:id="para_3132cdfd-616a-40cc-bdaa-5a8164fee101">a URI (the preferred form) identifying the source or destination,</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_e64ca8e5-35d3-4261-bb58-ccf407aaf2c5">an email address of the form "mailto:user@address",</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_efcb2388-dd8c-40a8-aa10-227e4fbc5212">a description of the media type (e.g., DVD) together with a description of its identifying label, as a free text field,</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_925e1c29-00ba-4581-9d61-d447f42bb8ca">a description of the media type (e.g., paper, film) together with a description of the location of the media creator (i.e., the printer).</para>
                        </listitem>
                    </orderedlist>
                    <para xml:id="para_f52fa99f-0778-4d89-af02-4e5762df8959">The UserID field for media needs to be highly flexible given the large variety of media and transports that might be used.</para>
                </section>
                <section label="A.5.2.2" status="4" xml:id="sect_A.5.2.2">
                    <title>AlternativeUserID</title>
                    <para xml:id="para_b4fac975-a8dd-4d87-b1d5-31d00d2e35b8">If the participant is a person, then AlternativeUserID shall be the identifier used for that person within an enterprise for authentication purposes, for example, a Kerberos Username (user@realm). If the participant is a DICOM application, then AlternativeUserID shall be one or more of the AE Titles that participated in the event. Multiple AE titles shall be encoded as:</para>
                    <para xml:id="para_027de0f2-b08c-4746-b7be-69565327721a">AETITLES= <emphasis role="italic">aetitle1;aetitle2;…</emphasis>
                    </para>
                    <para xml:id="para_3fab9fc3-cc72-4090-9a21-289cd44188d6">When importing or exporting data, e.g., by means of media, the AlternativeUserID field is used either to identify people or to identify the media itself. When the RoleIDCode is <olink targetdoc="PS3.16" targetptr="DCM_110154">(110154, DCM, "Destination Media")</olink> or <olink targetdoc="PS3.16" targetptr="DCM_110155">(110155, DCM, "Source Media")</olink>, the AlternativeUserID may be any machine readable identifications on the media, such as media serial number, volume label, or DICOMDIR File-set ID (0004,1130).</para>
                </section>
                <section label="A.5.2.3" status="4" xml:id="sect_A.5.2.3">
                    <title>UserName</title>
                    <para xml:id="para_7349182f-eb3a-422f-ad1e-15fb2c32e960">A human readable identification of the participant. If the participant is a person, the person's name shall be used. If the participant is a process, then the process name shall be used.</para>
                </section>
                <section label="A.5.2.4" status="4" xml:id="sect_A.5.2.4">
                    <title>NetworkAccessPointTypeCode, NetworkAccessPointID</title>
                    <para xml:id="para_99a82c9e-7258-4372-95d7-a74f45a7ff94">The NetworkAccessPointTypeCode and NetworkAccessPointID can be ambiguous for systems that have multiple physical network connections. For these multi-homed nodes a single DNS name or IP address shall be selected and used when reporting audit events. DICOM does not require the use of a specific method for selecting the network connection to be used for identification, but it must be the same for all of the audit messages generated for events on that node.</para>
                </section>
                <section label="A.5.2.5" status="4" xml:id="sect_A.5.2.5">
                    <title>EventDateTime</title>
                    <para xml:id="para_5583ac3f-7a88-4560-a781-8b069fc3a6c5">The EventDateTime is the date and time that the event being reported took place. Some events have a significant duration. In these cases, a date and time shall be chosen by a method that is consistent and appropriate for the event being reported.</para>
                    <para xml:id="para_b7e1c02d-3d92-4ba6-91c6-d2ae3b4271b0">The EventDateTime shall include the time zone information.</para>
                    <para xml:id="para_41a9b2ed-ebbb-4d60-a5af-eebab04ba90b">Creators of audit messages may support leap-seconds, but are not required to. Recipients of audit messages shall be able to process messages with leap-second information.</para>
                </section>
                <section label="A.5.2.6" status="4" xml:id="sect_A.5.2.6">
                    <title>ParticipantObjectTypeCodeRole</title>
                    <para xml:id="para_9d961ec6-80f6-41c1-968d-1c2e2c438eb1">The ParticipantObjectTypeCodeRole identifies the role that the object played in the event that is being reported. Most events involve multiple participating objects. ParticipantObjectTypeCodeRole identifies which object took which role in the event. It also covers agents, multi-purpose entities, and multi-role entities. For the purpose of the event one primary role is chosen.</para>
                    <table frame="box" label="A.5.2.6-1" rules="all" xml:id="table_A.5.2.6-1">
                        <caption>Participant Object Type Code Role Values</caption>
                        <thead>
                            <tr valign="top">
                                <th align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0c91b758-26b3-49cb-8d18-13853a089de6">Code</para>
                                </th>
                                <th align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fe0fb340-bd63-4ae6-9d61-492d470a89e4">Short Description</para>
                                </th>
                                <th align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_806f9a3a-d6c1-4128-a52d-3a87ec1dc05f">Description</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a08dea3a-7faf-4489-bfcb-1eb0631ee49a">1</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_83970230-2fb1-4b94-81c6-5117c4a04797">Patient</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6c648637-6e3e-4899-9631-a5bfa8d15d0b">This object is the patient that is the subject of care related to this event. It is identifiable by patient ID or equivalent. The patient may be either human or animal.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_12822a9f-f3f5-432a-95cf-af83d5677584">2</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9acb8e6a-e0ee-409a-a88d-ca85f130b647">Location</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b9cca6d0-ba9b-457b-9da8-b61ab3f5ce88">This is a location identified as related to the event. This is usually the location where the event took place. Note that for shipping, the usual events are arrival at a location or departure from a location.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_305de374-b505-4932-9614-dd19966642fa">3</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7743fcb8-b251-43fc-9e7d-fc88e421a275">Report</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e9b109f9-ccbd-4c9a-864e-dff6ff0dbd66">This object is any kind of persistent document created as a result of the event. This could be a paper report, film, electronic report, DICOM Study, etc. Issues related to medical records life cycle management are conveyed elsewhere.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a8acc4b8-2790-41e8-a357-2a2a39482992">4</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6fe0fba4-8c79-431f-a0b1-4b40cfb30661">Resource</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8280f3fe-28da-47f9-9de1-9392f8458c7a">(deprecated)</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7569371b-0e44-4ea9-b212-47206f82f75c">5</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ed764e8b-4191-42fa-8738-ca486359ce7e">Master File</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_08064640-f5b2-4a0b-902f-d6c80cf6fbbe">This is any configurable file used to control creation of documents or behavior. Examples include the objects maintained by the HL7 Master File transactions, Value Sets, etc.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0d607702-1c26-4c55-8b45-31abc69bd85f">6</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c5c5f5ed-9472-4461-8229-9972beb8c653">User</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_898290fa-947c-4215-8a83-63dd1d1eeb08">A human participant not otherwise identified by some other category.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7f4288d1-6f16-405d-91c7-ecde6d6c24e2">7</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d8cf1b20-76b9-4d46-8586-f1b689bc3a28">List</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0b6773f6-c76c-45f1-b1dd-23ec469647b6">(deprecated)</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6e38404f-e7d6-4b5a-8eae-bc56360065cf">8</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_db12207f-a1b6-4974-ad02-412966406c00">Doctor</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ddc5ce03-2e8f-4597-b322-94447b0f8967">A person who is providing or performing care related to the event, generally a physician. The key distinction between doctor and provider is the nature of their participation. The doctor is the human who actually performed the work. The provider is the human or organization that is responsible for the work.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_43c58fb2-d5a6-4ca0-8183-7f4a6661cfc4">9</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_87719f8a-5f05-4887-9786-e1d2aae70277">Subscriber</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c7c2d88a-dd92-4d58-9efe-bb0f518031a2">A person or system that is being notified as part of the event. This is relevant in situations where automated systems provide notifications to other parties when an event took place.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7a65d7a0-3f6a-4515-aa2a-31c2108f5f66">10</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d273f4e5-fec4-403c-8461-d19ff9ee220a">Guarantor</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b92e1901-c5d2-4732-863e-ff664c42bfa3">Insurance company, or any other organization who accepts responsibility for paying for the healthcare event.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_efbd9adc-0200-45ad-b939-0b92f53ba3d6">11</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_60f42ee0-c454-4351-8f5a-ec6983c48add">Security User Entity</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8a1b1a10-a1fc-4218-a399-1e23fbb1b6f3">A person or active system object involved in the event with a security role.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a3c4b746-810c-4619-b69b-7873b578114b">12</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e33bd601-720c-4198-8316-41a009fd1a84">Security User Group</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_597e4dbb-9556-4f7b-bf3d-2ffced00ec6f">(deprecated)</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_29159df7-b11b-4de8-ad48-cb8121b3a4f9">13</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_381210e9-10fa-47fb-b85f-1f0731f080a2">Security Resource</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ad65805e-99ec-4cc4-9e96-883e8b5bf302">A passive object, such as a role table, that is relevant to the event.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6efff348-202a-4abe-942a-11db8d50439f">14</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_845a07e4-84ed-4fab-8a88-3ebf4b7ff2a3">Security Granularity Definition</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e420aa83-eb53-4f30-9990-b7547648f5c7">(deprecated) Relevant to certain RBAC security methodologies.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_48ad704d-fe9c-4473-80d2-95f3abbf4e27">15</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_177e92fb-45e2-456a-98e4-66d4a50bb6ba">Provider</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a7b338fd-8c98-4eaf-8aa3-57005da7f41d">A person or organization responsible for providing care. This encompasses all forms of care, licensed or otherwise, and all sorts of teams and care groups. Note, the distinction between providers and the doctor that actually provided the care to the patient.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_09899775-1dfb-4906-a284-67e8f15e3ba8">16</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0762e6be-287a-40c9-9598-d851f10aa9ff">Data Destination</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6edb500f-ea08-459f-b9dc-fb27a48cbf2e">The destination for data transfer, when some other role is not appropriate.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_40c06218-e68f-45c5-a985-f6d80c6cb78a">17</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_39630b42-92fa-474c-a004-bb5857da1a06">Data Archive</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_faac0bc1-2118-4c39-9147-64cbf80396da">A source or destination for data transfer that acts as an archive, database, or similar role.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4cc265cd-00a4-4bcd-bef3-afa355f56fec">18</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_307f520a-ccf2-4d16-9c37-64ae9fc48669">Schedule</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c2d1e739-e765-4410-82f8-1e595b660615">An object that holds schedule information. This could be an appointment book, availability information, etc.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fd6d03ed-6456-400f-88e2-748cea38b417">19</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_67861354-e1ee-44a7-8c3c-f23bfd3e58d6">Customer</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_762db5db-70b1-4ca6-8723-4b1672883dec">An organization or person that is the recipient of services. This could be an organization that is getting services for a patient, or a person that is getting services for an animal.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d81d593d-f0c5-4f6a-9137-ecf454895268">20</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9f6ee09b-87b6-42bc-a69c-3ccb7e6058b3">Job</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_61b7cb2f-b620-43a5-aa0a-72bc2bd8f498">An order, task, work item, procedure step, or other description of work to be performed. E.g., a particular Instance of an MPPS.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4e50ea0f-efb4-4267-b0a4-bab4821ac73e">21</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0ad6718a-258a-4c24-8c9d-3901c239e76f">Job Stream</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f7205cb1-558c-4b83-97ab-abc52578009a">A list of jobs or a system that provides lists of jobs. E.g., an MWL SCP.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d4ece948-a4aa-4bcc-ae0d-0b097ef850c4">22</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3b3a468f-c5df-40d1-9ae2-353d65baebb4">Table</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cf0a5329-8418-4d9e-9341-405dec252a63">(deprecated)</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f80e9c8c-be1f-47a7-991f-ef5fc2873f3b">23</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_91741279-c6ef-4b45-b38b-c56e825478a1">Routing Criteria</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_993b0ac3-9a33-469b-b3c8-52bfb2fde06e">An object that specifies or controls the routing or delivery of items. For example, a distribution list is the routing criteria for mail. The items delivered may be documents, jobs, or other objects.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1ce88bd6-adab-4182-a41d-6a2f0df621dd">24</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8a0aca6c-dac8-40ed-a175-261567d0b256">Query</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_019050dd-7aa4-4fa1-aa0d-223e9ab7350d">The contents of a query. This is used to capture the contents of any kind of query. For security surveillance purposes knowing the queries being made is very important.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_dc9e5bac-bd09-49eb-a55d-1f6fe2b97b9a">25</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4e698e72-66e8-4f6e-80f1-be5c5a9cdb28">Data Source</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7b6e6b44-9af7-433e-8c8e-199446045ce4">The source or origin of data, when there is no other matching role available.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a782aeb9-68fc-46e2-8305-2e8074ae7781">26</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0359e635-7600-45f8-8285-9813f80e2875">Processing Element</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_dee81d2a-ab3f-4d32-b65f-5c98fb023bf3">A data processing element that creates, analyzes, modifies, or manipulates data as part of this event.</para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                </section>
                <section label="A.5.2.7" status="4" xml:id="sect_A.5.2.7">
                    <title>RoleIDCode</title>
                    <para xml:id="para_e25a176a-9a83-4958-93c2-3a86978c75f3">The RoleIDCode is a multi-valued element.</para>
                    <para xml:id="para_759aa14f-b40f-41ae-9198-4be0804005c4">One or more values identify the role(s) played by the active participant:</para>
                    <itemizedlist>
                        <listitem>
                            <para xml:id="para_e8813ed4-27b6-4d84-9c63-a06d2a05fe6e">Initiator: the participating entity that initiates the handling of the information.
                                The RoleIDCode will be <olink targetdoc="PS3.16" targetptr="DCM_110156">(110156, DCM, "Initiator Role ID")</olink>.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_5608f81f-454e-4d15-a733-a2b9aa11fa07">Source: the participating entity from which the information originates.
                                The RoleIDCode will be <olink targetdoc="PS3.16" targetptr="DCM_110153">(110153, DCM, "Source Role ID")</olink>.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_37d287d2-b2f9-4591-8bed-56b470fc1bb4">Destination: the participating entity to which the information is directed.
                                The RoleIDCode will be <olink targetdoc="PS3.16" targetptr="DCM_110152">(110152, DCM, "Destination Role ID")</olink>.</para>
                        </listitem>
                    </itemizedlist>
                    <para xml:id="para_1d561747-2e40-4a3e-aeb9-89f604d519fd">Additional values identify the type of active participant in this event, differentiating types of media and endpoints to provide traceability of the imported, exported or transferred instances in relevant system logs.</para>
                    <itemizedlist>
                        <listitem>
                            <para xml:id="para_d2d67411-f100-40f2-9bfd-2ec327d9cef3">Physical media: the participating entity is tangible storage with a unique persistent identity.
                                E.g., a USB drive with a partition ID, a CDROM with a volume label, or printed film with a physical label.
                                Include <olink targetdoc="PS3.16" targetptr="DCM_110154">(110154, DCM, "Destination Media")</olink> or
                                <olink targetdoc="PS3.16" targetptr="DCM_110155">(110155, DCM, "Source Media")</olink> as a RoleIDCode value.
                                The MediaType element will also be present.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_96ab0ba1-35e7-41bc-baac-6ab1acd50002">Digital media: the participating entity is a digital resource with a unique persistent identity.
                                E.g., an email message with <xref linkend="biblio_RFC_5322"/> Message-IDs, cloud storage objects with unique URIs, or network file shares with specific paths.
                                Include <olink targetdoc="PS3.16" targetptr="DCM_110154">(110154, DCM, "Destination Media")</olink> or
                                <olink targetdoc="PS3.16" targetptr="DCM_110155">(110155, DCM, "Source Media")</olink> as a RoleIDCode value.
                                The MediaType element will also be present.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_1330680a-eac1-487e-9b22-57d25fe0783b">Network access points: the participating entity is a network endpoint with a unique identity.
                                E.g., a DICOM Application Entity with an AE Title and/or an identifier for the network access point.
                                Include <olink targetdoc="PS3.16" targetptr="DCM_110153">(110153, DCM, "Source Role ID")</olink> or
                                <olink targetdoc="PS3.16" targetptr="DCM_110152">(110152, DCM, "Destination Role ID")</olink> as a RoleIDCode value.
                                The MediaType, MediaIdentifier, and NetworkAccessPointID elements may also be present.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_206802bd-ab3a-4758-9b1c-d392377bc940">Applications: the participating entity is a service that cannot provide unique identification for individual transactions, messages, or media items. E.g., clipboard managers (which cannot uniquely identify clipboard contents), messaging systems that lack message-by-message tracking, and some email systems that do not provide Message-IDs. Include <olink targetdoc="PS3.16" targetptr="DCM_110150">(110150, DCM, "Application")</olink> as a RoleIDCode value. Applications may be identified by values in other elements, e.g., mailto://person@example.com, process name, or service identifier.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_fbdcc026-8826-4bb4-a2de-02fe8db34aa6">Person: the participating entity is someone associated with a persistent identity provided by an organization.
                                E.g., a physician with provider ID or a hospital staff member with a network login.
                                Include <olink targetdoc="PS3.16" targetptr="DCM_110153">(110153, DCM, "Source Role ID")</olink>,
                                <olink targetdoc="PS3.16" targetptr="DCM_110152">(110152, DCM, "Destination Role ID")</olink>, or
                                <olink targetdoc="PS3.16" targetptr="DCM_110156">(110156, DCM, "Initiator Role ID")</olink> as a RoleIDCode value.
                                Person participants may be identified by values in other elements, e.g., UserID or AlternativeUserID.</para>
                        </listitem>
                    </itemizedlist>
                    <para xml:id="para_02628a38-fd2a-4a63-a454-720c444eaef1">Combined with identifiers in other elements, RoleIDCode facilitates:</para>
                    <orderedlist>
                        <listitem>
                            <para xml:id="para_fe73e962-1f2b-4a18-ab71-1997e5bed575">Locating identifiable media. For example, email folders and databases can be searched for an email Message-ID; partition-ID in system device logs can be searched for system media mounts identifying a USB device.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_fbc11082-498c-4896-9aa6-839717cde3c0">Discovering other relevant system logs. For example, a transfer labeled as “to” or “from”  “sms://123456789” can indicate that the SMS logs are pertinent.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_5ddce0e7-547a-48fe-a1f1-b735941171b3">Filtering transactions involving suspicious actors based on their type and role.</para>
                        </listitem>
                    </orderedlist>
                </section>
            </section>
            <section label="A.5.3" status="3" xml:id="sect_A.5.3">
                <title>DICOM Specific Audit Messages</title>
                <para xml:id="para_0230f55c-2cee-41ae-9f36-4113038e37ac">The following subsections define message specializations for use by implementations that claim conformance to the DICOM Audit Trail Message Format Profile. Any field (i.e., XML element and associated attributes) not specifically mentioned in the following tables shall follow the conventions specified in <xref linkend="sect_A.5.1" xrefstyle="select: label"/> and <xref linkend="sect_A.5.2" xrefstyle="select: label"/>.</para>
                <note>
                    <para xml:id="para_ceba8e84-600e-4323-b771-8fb59f0c52eb">This means, e.g., that the meaning of the fields defined in <xref linkend="sect_A.5.2" xrefstyle="select: label"/> is not changed. Furthermore, any of those fields or other optional extensions that are consistent with the schema may be present.</para>
                </note>
                <para xml:id="para_5a3e2ce6-3273-428d-b79b-d2f00646649d">An implementation claiming conformance to this Profile that reports an activity covered by one of the audit messages defined by this Profile shall use the message format defined in this Profile. However, a system claiming conformance to this Profile is not required to send a message each time the activity reported by that audit message occurs. It is expected that the triggering of audit messages would be configurable on an individual basis, to be able to balance network load versus the severity of threats, in accordance with local security policies.</para>
                <note>
                    <orderedlist numeration="arabic">
                        <listitem>
                            <para xml:id="para_b4ed2e21-c16b-4884-b1eb-930e39d2662f">It is a system design issue outside the scope of DICOM as to what entity actually sends an audit event and when. For example, a Query message could be generated by the entity where the query originated, by the entity that eventually would respond to the query, or by a monitoring entity not directly involved with the query, but that generates audit messages based on monitored network traffic.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_0ce0bf0f-3e29-4060-a60d-95bd81c4d25c">To report events that are similar to the events described here, these definitions can be used as the basis for extending the schema.</para>
                        </listitem>
                    </orderedlist>
                </note>
                <para xml:id="para_39fded3d-fa16-4bf4-9cac-6d98419eb873">In the subsequent tables, the Real-World Entities column indicates the real-world entities and their corresponding element defined in the AuditMessage element in the audit message.</para>
                <section label="A.5.3.1" status="4" xml:id="sect_A.5.3.1">
                    <title>Application Activity</title>
                    <para xml:id="para_4d773c0c-a2d4-441d-acb4-f2b5ddd88dcb">This audit message describes the event of an Application Entity starting or stopping. This is closely related to the more general case of any kind of application startup or shutdown, and may be suitable for those purposes also.</para>
                    <table frame="box" label="A.5.3.1-1" rules="all" xml:id="table_A.5.3.1-1">
                        <caption>Application Activity Message</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_cb75f99c-8b68-45bc-86e7-33d92e4032f8">Real-World Entities</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_80f42980-c156-4eff-9baf-764a8ad468f5">Field Name</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a04cbaf1-7cfe-4b59-a93c-c593fb15e388">Opt.</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_67514a71-2907-473e-8711-c94602b22289">Value Constraints</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="5">
                                    <para xml:id="para_f48db398-1d0e-4566-a4cf-54fe332dd3bc">Event: EventIdentification</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ff19c788-f68f-4249-840f-e559ad2b088a">EventID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_6100445d-4343-4af9-bae5-0253efdcf78e">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6fb78132-169f-4910-ab72-d1f5cc467946">EV <olink targetdoc="PS3.16" targetptr="DCM_110100">(110100, DCM, "Application Activity")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8cae20f7-bcd0-4e81-a755-0e942478afd3">EventActionCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_fa78fbaa-5c57-444a-b6c6-2dd3da8f6b81">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5f39fe31-67f3-4572-b3f6-3142e1cda3f5">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>E</term>
                                                <listitem>
                                                    <para xml:id="para_7ae60f02-c883-4c5c-a1e5-1ead9371ea8e">Execute</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1b2c9571-625d-4a83-bbf0-1bb18606d88a">EventDateTime</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_5956a110-e387-4836-ad9d-8ce28703e4d6">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9b0eea1d-b7b4-4750-836e-6c46c8a0e752">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_bc4aa905-8950-4db6-80e4-e98ee546222c">EventOutcomeIndicator</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_3764dbbf-9562-48de-8d3f-de0e2e3ba33b">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fd9c51a2-8cf1-4f41-b62c-b82319b3da67">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a25e374d-3807-4af5-9d2f-4b26a4135cab">EventTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_6a72093f-979a-4e82-8208-6b082e4c281c">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_479c6123-575f-48f3-94cf-09afe4a1d466">DT <olink targetdoc="PS3.16" targetptr="DCM_110120">(110120, DCM, "Application Start")</olink>
                                    </para>
                                    <para xml:id="para_0b084312-7d3f-42a9-a916-e87c441a9e88">DT <olink targetdoc="PS3.16" targetptr="DCM_110121">(110121, DCM, "Application Stop")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="7">
                                    <para xml:id="para_380ce81f-8a80-4e62-ad72-9105b48e2346">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_d0c2fb17-57de-42b3-92e5-3a76e0666bea">Application started (1)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_be23dd9c-a3eb-41dc-b2a7-7ce80bb453b9">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_16d719b9-b14b-4f6e-84f5-eff1143e52a1">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ea938414-bdbf-43c0-841b-5556cd465da6">The identity of the process started or stopped formatted as specified in <xref linkend="sect_A.5.2.1" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2edc23ca-ce3a-49bd-a38b-9534dc4de3e5">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_6929033b-a302-40a1-a11f-25b40bbd907f">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0d21e948-d290-4b2f-9c9d-d36de682deaa">If the process supports DICOM, then the AE Titles as specified in <xref linkend="sect_A.5.2.2" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_bcfbfe54-d0ec-4786-8757-ef32c6b75479">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_640bc1d5-1487-4f0c-8fdb-32c41142f2e7">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_59d7ae6c-468b-4fc2-898b-d8cf41aca507">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_50b359d0-ebab-441d-9ef7-05c9d1555bbb">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2f118004-9b34-4bb6-9b0c-69e0f0af3281">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_132c9ae7-9e96-413b-811e-77eabc6cfb6d">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cac6e0a1-35ae-4645-b47d-62223c938d11">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_6c183f62-2f69-402f-a05b-43195aad884a">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7a7a2ac3-3dc4-41c3-a1e4-af1508bb9ad4">EV <olink targetdoc="PS3.16" targetptr="DCM_110150">(110150, DCM, "Application")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_dfb20d51-3682-47e1-9123-2d82eaa5d31c">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_035ca0ac-d012-4e1d-a9eb-8d1574fa32da">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fe4708b0-8a17-4e6e-a50a-a86f595385cc">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3bb20484-b370-41fa-a8a4-4e177a8f5a35">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8104cbba-491a-4850-9cd5-638ebfd453c4">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4a9c5074-c8a6-4a81-81ca-3e84e1eb2fa1">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="7">
                                    <para xml:id="para_d035adc6-e57f-4def-acc4-eeb776fc5e4e">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_865b4676-7ef0-4ca9-8fae-c044c575d7f1">Persons and or processes starting the application (0..N)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_882a3461-d90d-4818-aa66-571c5e497238">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b0eb4ac1-07bc-40e5-b535-a4a07856bff6">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_60f26008-f87e-4501-b657-aa05083587be">The persons or processes starting or stopping the application.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b8083a4e-a461-45e0-aa02-426759fb0966">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ed7fe40e-c55e-44ea-a9ca-0e0c3effa842">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_df5ec4ca-abb1-4503-bf24-4885b8f53bb6">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_00caa3ce-a4b9-4b8a-8736-3e60a9bc6c53">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_76cfa58f-fc1f-48b5-b499-009808c4f4d0">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_afc28dc3-2c18-46c8-935a-a4872db43e53">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d99f5674-f88c-4fc4-a532-0d58ed177e8a">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_cf9b7a80-a9bb-4f0d-a7c9-abdbb9c67bf8">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0837c204-daaf-4dd7-8ca4-96240adc8868">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fa3a26b1-e2b1-4e9e-829e-dae2d4d7a1e7">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a9137ee3-0769-4865-a17e-abe080ba4e66">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_80d162fb-9f5d-4412-98f0-0dd0b18282b3">EV <olink targetdoc="PS3.16" targetptr="DCM_110151">(110151, DCM, "Application Launcher")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_64e5c229-65a4-4866-88eb-fa40749c9fd4">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9e291f45-45e1-43c4-b7ec-b8f4004b6d2e">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_88f6ff35-0916-4f0f-ae08-ec8ec06a8b1f">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f8628143-6514-468a-aaba-3c040326616c">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_72c19de7-8592-40d5-a39c-3068f8556257">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0b916b7b-9da7-4e10-abbf-ac26e0a1c8ad">Not specialized.</para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                    <para xml:id="para_eb73e661-4162-44f3-a843-e62bd767947b">No Participant Objects are needed for this message.</para>
                </section>
                <section label="A.5.3.2" status="4" xml:id="sect_A.5.3.2">
                    <title>Audit Log Used</title>
                    <para xml:id="para_f6159583-5686-4d99-96e8-698d30f9b2f0">This message describes the event of a person or process reading a log of audit trail information.</para>
                    <note>
                        <para xml:id="para_1e4aae3e-5661-4982-af98-fe39e78ea5bb">For example, an implementation that maintains a local cache of audit information that has not been transferred to a central collection point might generate this message if its local cache were accessed by a user.</para>
                    </note>
                    <table frame="box" label="A.5.3.2-1" rules="all" xml:id="table_A.5.3.2-1">
                        <caption>Audit Log Used Message</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_5c90befd-96e4-4fbd-b6f4-1990eadb11f8">Real-World Entities</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ebc27569-e2ad-4890-9d1b-08b45d78ab60">Field Name</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_fe1d313a-6bd8-4b95-8c26-16484e483a5a">Opt.</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_1e16bc5b-fee3-4d62-8a85-ff66cedf2534">Value Constraints</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="5">
                                    <para xml:id="para_23df9a8e-2872-4c7c-893e-17c83f32e7da">Event: EventIdentification</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d3aa20ad-3e21-4317-b876-bd4ebba1e695">EventID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_d07f9691-8cb1-4f83-9bb9-5261811066d5">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f2f64133-5cef-40ad-b565-c2e26349c1bf">EV <olink targetdoc="PS3.16" targetptr="DCM_110101">(110101, DCM, "Audit Log Used")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ce478cc7-0044-43b5-abe4-56b0057ed62a">EventActionCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_926ae9c0-9a46-413f-8365-e6d2a9d6a091">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1cd2e0cc-0c33-4307-97f8-62645f8a7ede">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>R</term>
                                                <listitem>
                                                    <para xml:id="para_479e31ec-8cc8-4874-82df-ef80132c9ee0">read</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5c198500-bf53-468e-af08-5a3043c36f97">EventDateTime</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f5ea2a98-8fa7-4653-a123-a6f13e90a441">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b5cc71bf-e72c-408d-8f72-ade9f93c0a18">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cee8f513-57fa-4ef8-bc73-5d8ab69b0de2">EventOutcomeIndicator</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_188ea671-803f-4983-becb-5c70444096c3">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fbd00b6d-292f-4860-8d25-ca81dd07490f">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a5b72681-c4e6-4899-bf80-2df8b026c6e9">EventTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_eb252b65-ca9a-4f19-935d-741afea9d941">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_01a5df3b-5320-4a61-b509-a2aa679b49f5">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="7">
                                    <para xml:id="para_d51e9b06-2b45-48e5-831b-8c70658b67bf">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_4b29dcba-ac38-45f1-85b4-d788f9be8460">Person and or process that started the Application (1..2)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2673ae31-ce7a-4ad9-80a0-76dd34f2a35d">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_65768a4a-a198-4693-b9b7-c877c63672cd">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e3a0936c-c7cc-466b-bc36-ab6fb03aee03">The person or process accessing the audit trail. If both are known, then two active participants shall be included (both the person and the process).</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_124e9697-bf32-4e82-8bd6-5af117e4bca5">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a02dc43c-76ea-4867-a4d3-28f72dd370e1">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d33c70fa-53b6-4b82-875a-617023059399">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7138ea75-d146-4d16-a868-e2478fe4f848">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f42051cb-50bb-447c-b7c8-8f5393bddb23">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3023d8bf-5dc5-431a-be8e-dbd6c86d0776">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_39654bfb-fc6b-477c-8269-649ff5db91ff">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9af88a2b-bc29-45fe-befc-dbe71538620b">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_38e564fa-4b58-4336-ae90-c55ae73153a7">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_451f4c07-473e-42c1-8fc3-99acbaadfa74">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_69db559a-37a9-4a88-bb06-c9113e676698">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d7df4cd6-33d7-42be-b2e3-d7af5f7fcb4f">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5effd79a-33b9-4723-b7a8-9e4a30955f50">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_d856c2d8-5ee1-4921-be5b-203c69d1d9db">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cd8104cc-5f04-4e53-9cdc-26d05467d844">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_28f538fd-440a-4756-94c0-cceeab8709af">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e8893c1d-9fa1-4bad-8603-c3953a704d3c">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_71668070-ed74-4481-99d4-a94faaec63b8">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="16">
                                    <para xml:id="para_e06a965d-516a-4cab-a75f-4d0587497c18">Participant Object: ParticipantObjectIdentification</para>
                                    <para xml:id="para_f97967ed-507b-4f7f-8ec8-a3dfcc9164bd">Identity of the audit log (1)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_493ecce1-7a9f-4b45-aec4-7f8de942e7ea">ParticipantObjectTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_3f41b3d1-33cc-4ef8-92fb-8db0fffad979">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d9c2ad48-acce-4732-ae26-26da9125f76d">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>2</term>
                                                <listitem>
                                                    <para xml:id="para_923df075-0de4-4a9b-b8c4-7b026114787c">System Object</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_513c0489-d7b0-409e-bfa7-6dddca053498">ParticipantObjectTypeCodeRole</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_86f0839d-0379-41f5-aeee-f8d6ed4b3bd2">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f72ad506-f38b-4426-96e6-ac443b9cb18e">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>13</term>
                                                <listitem>
                                                    <para xml:id="para_574598d9-13b6-4cdf-8d0e-d5567b17a7ca">Security Resource</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9a331ef8-272c-435f-bde7-581d28378dd3">ParticipantObjectDataLifeCycle</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_db0f8c7d-7b39-4dec-8695-fa9087add829">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8bf70074-65ba-4b75-b287-0aa64fce8ffd">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9bc74c75-e5cd-413c-a9c8-eab491bf1cdf">ParticipantObjectIDTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_95eaeb7b-e2da-4437-8a1d-92edfc0d56a4">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_71bc3e87-7d42-4000-8775-2298239be7f1">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>12</term>
                                                <listitem>
                                                    <para xml:id="para_5e0147b8-37b8-4009-b41a-377f0b3b4536">URI</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3f65ca3f-5601-4c8e-a162-0d5c24ab901e">ParticipantObjectSensitivity</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_1a51734b-e670-4230-857f-160caa56c227">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3b831af3-23f3-48ce-86ea-48adf759660d">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_892dde74-8549-4e99-a66f-bac9a7ab741d">ParticipantObjectID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_cc19f748-c57a-4fc2-8227-d81a310f5100">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cffb6fbd-0676-461e-b2f6-72b4e28ce6b9">The URI of the audit log.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b0d464d9-d590-4bc3-9775-33f89970ff2c">ParticipantObjectName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8945d3bd-704c-4a44-8d2b-8e3e2ac2890a">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_81cec541-a633-497a-93d0-f2fc6ef21ca2">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>Security Audit Log</term>
                                                <listitem>
                                                    <para xml:id="para_0972488c-63f7-46d6-9f39-b6b428f2537b"/>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f1840f60-ee8d-458c-8d9c-961952371cb4">ParticipantObjectDetail</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_3b9c7c8d-8813-4a77-9080-6c2013fe0b43">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_feb3fc85-13be-4c1d-beef-07cce6a4af29">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3d42ff62-a1c7-44d0-8ccc-da940fbea54f">ParticipantObjectDescription</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9337c7d9-8598-447e-9c3c-c15369d16402">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3e6e06d6-e59e-4019-ac23-fe0c907d052d">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f53a4181-5e4a-4a17-86bf-1e211971d5b9">SOPClass</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_663ed480-70e9-48fc-b1f0-fae1f63955c9">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_109fe576-9c7c-458e-981a-25ca9a9a726e">See <xref linkend="sect_A.5.2" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c36fe389-876c-44fe-9129-b80fcd39d4fa">Accession</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a0945330-7dcd-43b1-b1f0-e7e9edadcd53">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_52f1bad9-0a2a-421b-9884-4d1b107c0a1a">See <xref linkend="sect_A.5.2" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_95f293aa-a62f-46c4-b1b5-810ccd95ce18">NumberOfInstances</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_867cb77d-e3c8-431a-9e36-2d42b7dedcfd">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e187a574-6353-4057-97b5-ab725aa75064">See <xref linkend="sect_A.5.2" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_130223dc-961d-4d6f-bf3e-7f2ef5ba7577">Instances</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9c93e5c8-375b-4be2-bfa3-5b9d4039dc9f">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8447add7-c5c9-4396-bc36-51526801e1ed">See <xref linkend="sect_A.5.2" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_44774299-fc74-4c92-99bb-2d3f3cf38de9">Encrypted</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_d97a3106-1966-4952-9512-b33a98036092">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e69f9e95-1c25-49aa-abf0-1f9726187f3b">See <xref linkend="sect_A.5.2" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_71380258-ddd8-4957-aeb4-5c6329b348b1">Anonymized</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_571385f1-d489-46b5-84b0-827d3a10822b">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_81bf51c4-130d-48a7-a882-09619735a170">See <xref linkend="sect_A.5.2" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e068e6a6-4629-4d0d-95fc-5e1cf258fbac">ParticipantObjectContainsStudy</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e4ac7627-9f52-4eb9-8254-cae6553cf69a">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_47bf02de-40cb-4133-ab19-1577b590eda4">See <xref linkend="sect_A.5.2" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                </section>
                <section label="A.5.3.3" status="4" xml:id="sect_A.5.3.3">
                    <title>Begin Transferring DICOM Instances</title>
                    <para xml:id="para_d93ff691-95ac-435a-8d1d-20c088df9e19">This message describes the event of a system beginning to transfer a set of DICOM SOP Instances from one node to another node within control of the system's security domain. This message may only include information about a single patient.</para>
                    <note>
                        <para xml:id="para_dc6cf2c6-a9ca-49ec-a5b4-a421aec42b68">A separate DICOM Instances Transferred message is defined for transfer completion, allowing comparison of what was intended to be sent and what was actually sent.</para>
                    </note>
                    <table frame="box" label="A.5.3.3-1" rules="all" xml:id="table_A.5.3.3-1">
                        <caption>Audit Message for Begin Transferring DICOM Instances</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_82126ef8-ee49-460d-a822-68830fb66e39">Real-World Entities</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4080bb84-7a44-4ca0-892a-8e9a33eded2f">Field Name</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_447b7c97-ee4f-4fd6-81c7-de5e833a29ba">Opt.</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c137cd33-c8c4-4a7f-a1b9-48977e34f08f">Value Constraints</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="5">
                                    <para xml:id="para_33a268cb-d8c9-4811-a53e-6ffa370d90ef">Event: EventIdentification</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c86cd2ff-6921-42bb-8810-ac6cf0f72be0">EventID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c19302ae-108e-4431-9c44-b07b547a0ac5">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1f04b6c1-1e2f-48dc-b1d4-9130bbdce3ee">EV <olink targetdoc="PS3.16" targetptr="DCM_110102">(110102, DCM, "Begin Transferring DICOM Instances")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_869f9fd0-7a61-47e6-88eb-2e24b3e392d5">EventActionCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_038b4013-be6d-46fe-a4df-8dc46f0dca0c">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d8b2c5a0-d8dc-456f-a366-8e64092bc850">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>E</term>
                                                <listitem>
                                                    <para xml:id="para_47c1c89f-3787-4e35-a0ed-fb8605963ba2">Execute</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6a59f6d9-9c2d-4be6-9495-d7eb92cb9929">EventDateTime</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_82d158cd-93d0-45b9-a201-778b946d3f87">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_45a0db7a-d49e-4fdf-9a31-fa3fa2d9a4ee">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c531f0a4-d725-439c-990e-90aae051cd8e">EventOutcomeIndicator</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_56c1da0c-5671-4556-ab27-2558895f0c73">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_92207d61-e7d2-435c-9f31-11f204ff7aff">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_42f7a3b8-bb1e-40ac-afa2-d0de8c35ed9a">EventTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f6434c23-deec-4871-b7e8-e5a7dc7f64c5">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9bb1d8cc-bbda-4592-96a6-a9e045cbcb6c">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="7">
                                    <para xml:id="para_e45136ab-dc71-4633-b06a-9ace4bcb635e">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_b181d7b4-f302-462c-b577-1c424cd23a24">Process sending the data (1)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_86a3009e-0858-42be-9e33-48e2138f1d82">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_82087f7f-45d4-4745-b334-6aa8ca266372">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_79d9b535-8ee0-4f11-8dc4-fa4c513236ce">The identity of the process sending the data.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8d3606f4-6eef-469d-bbac-9dbbc930631d">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_95f28516-38ea-4343-8972-2108d006b8c6">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_93b3e12b-75b2-43ce-833b-4d58290ea361">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_069c3126-062f-45cb-a07d-1109073658fa">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_d51ae4de-7cd1-4583-8ccf-431528e4c281">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cd1ef552-577d-48f8-8e55-c6b72fc1c397">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6478f5c1-bc07-4ff4-a306-f860c65a9a4d">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a11b30a2-2662-4485-ad33-9d7a18cdc999">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_75802584-c325-4b18-803c-851aa4b52150">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_80aff2cd-7f6f-4c2d-a1cc-79e21d96747e">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2e744154-1b0f-4bf9-96f1-89eec92afb07">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_376e9446-5131-452f-9bc4-e14b1d5c22ff">EV <olink targetdoc="PS3.16" targetptr="DCM_110153">(110153, DCM, "Source Role ID")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_07373899-508d-4e4d-af17-73c4f99db6c7">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_3f995c1a-2be6-429d-b240-193e5dc68098">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fb5c67fe-c193-46f9-9daa-73796472500e">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3bdbad05-8042-4e29-af72-ab51dedac9c3">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b8f8e35b-1408-4cf3-ad1e-cabeeeae0cd9">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6dc0ad2e-fd32-4718-b89d-b3e1179c803a">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="7">
                                    <para xml:id="para_722028f9-fee9-4449-b590-8081063c1a90">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_aadb1d30-891b-4e08-a2d3-d9d976f8cc4b">Process receiving the data (1)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_82b3e049-2d00-4020-933e-2b73782a272c">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b61052ef-f46b-40b8-a047-92306fbc16d3">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b7a95bc7-059b-452e-bfb0-de38585050b2">The identity of the process receiving the data.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_100d7552-90e8-45c7-b487-f6d99152e7cf">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f09a7368-896e-4d59-9ad7-627538f86a4c">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1bbf7ec3-0c98-472b-9abb-bc5e07b81b60">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1f769bc5-f601-42d0-a2fe-bdbbf8955f0a">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_0cffdb3c-cdf5-4bcb-8db2-1ed24dbf4741">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_befcc77e-a437-4a3e-a030-df5329f6344f">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_922e0abe-ecd1-42be-9319-b01cf1112536">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b9b774f3-edb0-453c-af03-6e77d9333f3b">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e0474a28-4d05-4cf2-9489-8da809a82601">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_767a3bfd-1543-4b93-9747-100e5a11812d">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_debd92b4-0ca0-46c0-a839-d9efddcb5e58">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_22a5a7c9-6227-4567-a656-d452de180029">EV <olink targetdoc="PS3.16" targetptr="DCM_110152">(110152, DCM, "Destination Role ID")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_513d1ee6-6c16-4e16-b61b-18ae0fa24a8b">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2a7893bb-a328-46f8-96cc-b8f78507c2c9">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4947f0ea-e046-4229-a399-ea2cf5d77ffa">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8b255d7c-1aac-467c-a8a7-f612d8ddfbfd">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_060cace1-8619-4520-b192-1e1e7c91bef8">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_deda13f8-9db7-4fd5-9eb5-fafa9b0e899c">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="7">
                                    <para xml:id="para_175e345f-435f-4506-98aa-0cab81abd389">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_a8be1282-7de7-4a01-a10a-e85b8a72c2f9">Other participants (0..N)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2d8fb718-d5f9-4fe7-b69d-6b1b4b98fdeb">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_5e35e139-0b37-4c94-b80b-462c47ca2de5">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_de8a7afd-754e-4778-9254-604850270b36">The identity of any other participants that might be involved and known, especially third parties that are the requestor.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6474754b-0281-41be-a230-05f2ea8e35c9">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b55148a9-c7f5-43d2-8f34-07fbd716361f">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fe5f8eeb-8d8a-425d-8440-f1a3db435819">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_aa8091c9-4348-4007-bb82-cc2f4bf7b238">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_bf5049e0-a028-40f5-a162-031d84d95b27">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_bbb2f31c-08d8-47ca-939e-2a2401415871">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1ebc5694-6987-49ff-9754-335f24e3b28f">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a1f398da-eb07-4449-a587-f35e0552cc28">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2ea8483b-7242-4a47-95d1-33e5b4279c99">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0ccfddd3-1ce5-4313-9aac-3d82e1945693">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b837c6fd-7de7-4cf2-87e0-ec9d01620a4b">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0a89fba7-9a43-4875-8e40-ac949d4b215e">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_faaefb50-032e-4311-a5fb-789ef5b46a24">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_1974faa6-d3ae-4bed-bfa2-fc09492c5f4f">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_64af88a3-776d-4d1a-864e-a332dadb1e96">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e65bbdf7-5d3b-4f39-97fe-ca06c808147d">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_91a326fe-3704-42a4-81b2-4944c8c08eb6">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d1130fee-5db5-436c-8944-9bf1c63a0a5a">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="16">
                                    <para xml:id="para_ea82f083-c43d-4cf2-91ee-44a91785aa33">Participant Object: ParticipantObjectIdentification</para>
                                    <para xml:id="para_61d87c19-65d5-489d-80ba-3f755640c18b">Studies being transferred (1..N)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a022d426-d708-4b99-91b0-1ad65d27ad9b">ParticipantObjectTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_fe101fd9-e1ca-426c-8d5b-188d3b280f34">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9612a35e-7bc6-47cc-8448-34c47535a515">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>2</term>
                                                <listitem>
                                                    <para xml:id="para_cd975cc2-496e-4bd3-af1c-1d491a8131d9">System Object</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_901ba545-67f8-45ac-b3b2-a968a3a1b4e4">ParticipantObjectTypeCodeRole</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f4443d66-2cf9-44fc-826c-df8947994192">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5cfad272-af73-4518-b482-afa98ca62e20">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>3</term>
                                                <listitem>
                                                    <para xml:id="para_9b4a1665-aa72-456c-8afd-ef2f294d7ffe">Report</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5c0ea4a5-e682-48fc-9bfb-9d201d6b23e0">ParticipantObjectDataLifeCycle</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_17995551-0d8b-4884-8fa7-4bd29c905aed">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_43fa7d25-4a34-4df3-8524-1c42f2a836f3">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_31149921-37e3-4bab-b52b-7bcba1725296">ParticipantObjectIDTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_3c373b77-0963-4eb7-bcb8-f59117c4710a">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2722d90d-34b0-454a-b667-af894271dc18">EV <olink targetdoc="PS3.16" targetptr="DCM_110180">(110180, DCM, "Study Instance UID")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_94a074a5-401a-4216-abd4-31f7997adae2">ParticipantObjectSensitivity</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_75f473c6-5970-476b-b2e9-4014b92983ac">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_00854aef-60b7-45eb-9ba4-2fa664e08ff9">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_08d11f49-e1d1-431c-ab75-46d2241c8874">ParticipantObjectID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f1aa8e97-b4ff-4a37-a993-c8d112bff962">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7fa65cd6-4859-4b5b-81b8-1d35e393f0d7">The Study Instance UID.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fb14332a-0c5b-46cf-8ccd-bd921fc9435b">ParticipantObjectName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_272b1cdf-64de-45e2-8fb9-0b8bffbbbe36">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1ba98c17-336b-463a-b138-e623f65a0bac">Required if ParticipantObjectQuery is not present.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4ce6ee00-11ed-46d9-9e81-bb0c55beb92d">ParticipantObjectQuery</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_dc2888d3-3eba-47c5-84ba-beaabcc33be9">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ad791a76-bae6-4184-9f5a-fb6306ed74cd">Required if ParticipantObjectName is not present.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9d64ad9b-271c-4b37-9f91-3619d902f7fb">ParticipantObjectDetail</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_20bbaa63-797b-44fa-8848-236db1b20b15">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a1b9a691-2bb2-4321-b760-41b93141d0ab">Element "ContainsSOPClass" with one or more SOP Class UID values.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_793d3f61-0a84-48f4-82c6-36d2cb4831fa">ParticipantObjectDescription</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8c247da7-ed37-4903-9a60-f531da16e986">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e6936061-c383-4539-b40b-596723a1ac1f">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_547a588f-dec8-47ce-b9eb-003510e2bae0">SOPClass</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_d4d8beb4-f1f6-4112-a81b-0e40323f5508">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6d31f79d-c825-42fa-bdd0-eef151dbd9bf">Not specialized.</para>
                                    <para xml:id="para_c14a0719-be7b-4072-9b62-83c564abd939">See <xref linkend="sect_A.5.2" xrefstyle="select: label"/> for conditions.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_af6a0528-f7a1-44c5-886e-0e6239628626">Accession</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_7097abf2-5938-421d-b9a0-2eef4964fc95">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_455a408c-333e-47eb-a18b-79581039cedb">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3480dc81-180f-484c-8700-e3f31ac9cceb">NumberOfInstances</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f434bf73-3ac2-4dc3-a00b-c830be52d02f">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_57920ca1-e4b7-402b-a5e5-a2a601831113">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9e31422e-5b6a-4f1c-a7dd-302377531a35">Instances</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b4bd0e70-57ad-4c38-89b1-2ef8078a17b2">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fa86af84-4cb6-41cd-9b39-30bf2a782a7c">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d8fa174d-efd3-4e1f-820b-0a64c620e64d">Encrypted</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_715c0d1f-87d1-41e6-97b9-fe360bc03417">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_daa5bd13-c521-42e6-be70-f7ab56322610">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e67116f1-41c7-4c35-9218-075ad74e04c5">Anonymized</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_83d3f70b-192e-46ac-b2fa-6d126840d699">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_00c1182a-a86b-4780-a547-e98816aefef2">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="9">
                                    <para xml:id="para_81c409ce-0ecf-439a-b135-b9820e144b61">Participant Object: ParticipantObjectIdentification</para>
                                    <para xml:id="para_56411702-8e76-4e2e-92c4-8ffb02a89776">Patient (1)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c7fd3128-5012-4a0d-a3b0-4f59c02ac191">ParticipantObjectTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2a2d9d52-4928-49b4-b6d6-f1c2818737a1">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f2e7df1f-6bbc-48b2-8f49-b8eafeeadd67">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>1</term>
                                                <listitem>
                                                    <para xml:id="para_8e7c4caf-438e-42bd-9972-ac760e251691">Person</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8cd14ec2-b6e4-4412-a719-7b100d62fcb4">ParticipantObjectTypeCodeRole</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_db94ced0-856e-4da1-b3c8-dc8b16d3ad87">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_afb36105-bc04-4da6-8773-58f4ad191d19">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>1</term>
                                                <listitem>
                                                    <para xml:id="para_9a837bf1-54fd-4a47-af32-8c0854ddbf39">Patient</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8c52c552-0919-4e52-b61e-5770b105d563">ParticipantObjectDataLifeCycle</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8d5343d5-d987-4575-8bd1-6c20c0b789cd">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e57413f9-6940-4166-b6e4-146cb10210a0">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e6c847c2-92c6-4e1e-b8a6-17ebe2cdab03">ParticipantObjectIDTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_558ac604-1cf5-4d82-950b-95718883f5c5">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e131e54c-3dc1-4520-b667-de5f029fd098">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>2</term>
                                                <listitem>
                                                    <para xml:id="para_42ce431d-0dc9-48df-8438-d5d573ed60a7">Patient Number</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_747f6905-0244-45af-919e-67d37cf2e8e8">ParticipantObjectSensitivity</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_fc65facc-38e0-4e8f-8eb0-eb664d612de9">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_082ee86b-65f5-47f1-9f32-f6178e005b93">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c44a1dbd-834c-4cfc-a3d7-60906d353991">ParticipantObjectID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_241a6c71-b296-4a4e-8a17-82221dee0225">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_91d812ed-9d18-49b7-b238-0e94fc924379">The patient ID.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c983c005-b504-4beb-9e9f-06ff43a54b4c">ParticipantObjectName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a4f2c7c9-1f8e-41f3-9a86-947e00c6df6c">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5d322c08-0bbb-4545-bad5-2ac29c742155">The patient name.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a67be82b-5149-472b-a64a-4063c81caa6c">ParticipantObjectDetail</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8d3f41fe-08f9-430e-952c-db289432cb3c">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b3fb1aa2-0497-4bdb-be07-fa9cec155f93">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7d26a007-26a9-40b7-930e-4ec9b67d9dcb">ParticipantObjectDescription</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ebb8f8de-002a-4831-a727-9e897cb908bb">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fe273ce1-548a-4a3b-8198-7345f8faf5ac">Not specialized.</para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                </section>
                <section label="A.5.3.4" status="4" xml:id="sect_A.5.3.4">
                    <title>Data Export</title>
                    <para xml:id="para_13f11c13-7579-4c31-a713-dc59c4fae545">This message describes the event of exporting data from a system, meaning that the data is leaving control of the system's security domain. Examples of exporting include printing to paper, recording on film, conversion to another format for storage in an EHR, writing to removable media, or sending via e-mail. Multiple patients may be described in one event message.</para>
                    <table frame="box" label="A.5.3.4-1" rules="all" xml:id="table_A.5.3.4-1">
                        <caption>Audit Message for Data Export</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_970dc4a7-71ef-4f8c-9f3a-c59e6a2fc067">Real-World Entities</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_86f5c907-3aae-480b-b1ba-59b54ea92abe">Field Name</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f9eb14bb-b70f-4863-b29b-0a380a486482">Opt.</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f10ac9d1-641d-4d8e-b48c-d33a6fef29f4">Value Constraints</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="5">
                                    <para xml:id="para_bbefc93a-a8ea-401f-898f-9b6550a04958">Event: EventIdentification</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_76472fed-6838-4cee-b158-276632512b8f">EventID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b20357a2-8fe4-4ad9-b466-789fe018f03a">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8adf976f-09ae-4288-8d80-9d327290e313">EV <olink targetdoc="PS3.16" targetptr="DCM_110106">(110106, DCM, "Export")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1322761a-1d56-4694-b0be-8bc1993af5fc">EventActionCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_dae4e817-1c26-4877-bde0-3a89ba731719">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8e7e5f28-9588-4ce7-af89-5e584438c9f0">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>R</term>
                                                <listitem>
                                                    <para xml:id="para_7bf20275-b26a-4bc0-878d-2cc74a56da99">Read</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_dfbf8627-2327-4743-ab60-09542f243194">EventDateTime</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_fda0190f-75e8-4949-8f01-613e35e5b147">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_892b0c14-273d-4ed2-a085-7dabdb3e5cc9">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_81c6d6b2-efc4-4d4e-b426-0061066cb40a">EventOutcomeIndicator</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_0dcb2ae9-1974-4949-815d-a5a07a0397f6">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8aeaf6c8-2d4c-4b32-a0c7-0a78932dd926">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e58e1825-cc35-4a14-82d7-403cf89a5b2d">EventTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ea17572a-3b2f-4953-9631-6d4368748dc5">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_66a8de55-f50d-466d-a242-7eaf5678050c">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="7">
                                    <para xml:id="para_7cf74550-7e8f-4a7d-918e-4ed21474b7b4">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_922f080d-9f24-490d-a833-f55b2c55ec93">Remote users and/or processes (0..N)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a519f8fc-01f1-4db2-bcc4-0f18493b2e52">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b788437e-159e-4f67-bfd9-05cec1aa070f">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_094563b8-e101-4ca2-8bc9-501e7a583ce5">The identity of the remote user or process receiving the data.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_43349a69-abc2-4603-ae9b-4db966738f38">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_045920f7-25f1-42d7-89f5-f2b8022991ef">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1f689ade-2a8e-448c-b3fb-f7d4f02bd49b">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f11725b4-528b-4fe1-878d-c753a147e060">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_68fef86d-85c7-47b3-b469-433584216a8b">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_bfa5fe91-f7af-43bb-bab6-ea39eeed2d09">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6b25e403-e1a5-4c2a-9e0b-c5e9295007b4">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2e3726e9-abc1-4e82-9b7a-a57835322c6a">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2388e358-a153-41b5-80e8-23471a627961">See <xref linkend="sect_A.5.3.4.1" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1d78d499-4e3f-4b1a-9712-ccf9e1971c3a">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_05883ef0-850d-4a2b-bbd1-9aa0d69857a0">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2b44032a-65d4-42da-8fb5-ea7acacbee38">EV <olink targetdoc="PS3.16" targetptr="DCM_110152">(110152, DCM, "Destination Role ID")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6fb365e1-9b84-4e9f-87dc-8395d3d567b5">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_3e10ddd9-8eec-40e0-a08a-6dd5631e696d">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_71c66687-6d0c-4cc4-b25f-7f72198854e5">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3de012ff-2109-4074-9ef0-83d9a2cd730a">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_77524a01-ef24-4752-bb51-040a974804cf">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7f948766-1671-4a0d-bf12-0a8ea108479d">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="7">
                                    <para xml:id="para_8fc658a5-0178-42a4-87a9-d54bdc3d2a05">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_60ebee1e-13c1-4a0b-b0c8-b76eea5303c3">User and/or process exporting the data (1..2)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4a32e279-6ef8-4e56-856f-76ebb07b42f1">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4cafd69e-0ec8-4b41-bb1f-1bf60350ca25">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_004adc51-048b-423f-8a6d-a0733a73c2e6">The identity of the local user or process exporting the data. If both are known, then two active participants shall be included (both the person and the process).</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_591ee12c-1c7d-4f7b-b6a7-32f13a50ef3d">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_dcfc4a0a-cea1-463c-836b-5c017b675218">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5fdfd288-046e-497f-a3c1-65e6097c2ebe">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0fb5e6f8-a034-4a7d-9631-a462795e313a">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_86979191-406d-4c48-ae6e-325756992014">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7879d61e-ab74-40c0-aed7-f9f6fcdc50ad">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_37e2e5ca-5b8c-4aa6-be01-02975c4f777c">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c205e747-c97d-4017-9a3d-5fe438d0682f">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_42e79a28-4763-4be6-8251-144d50e8cc68">See <xref linkend="sect_A.5.3.4.1" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_123f52ff-bbd4-41c0-98d8-57ebae51b93c">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_46699521-02ec-4b2e-84dd-24b921ea8abd">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9bdcb2dc-34a8-4e59-8655-2260cfeb21ae">EV <olink targetdoc="PS3.16" targetptr="DCM_110153">(110153, DCM, "Source Role ID")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5ea8cd39-d186-46d6-9dad-477d284b4d2a">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_3e0a31e4-9b48-44ed-b029-1e68037519e4">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_81bb159c-dfa0-442f-a852-46dcd55efdec">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5db61395-a3d3-419b-8ea7-eb0cb70f46a9">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b09bfb51-bcc7-48f4-a971-cb24f3dd5de4">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3c62d4f3-1965-4f19-bb61-ae28424453d3">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="9">
                                    <para xml:id="para_aa243a0a-5748-441a-a9ca-18495d415df7">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_fe30349f-e376-40c0-83c0-f4375dd89471">Media (1)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_defb85f6-9c95-4e7b-b20f-34033ca271e5">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ec3e167c-3182-4d8b-b999-5849cc1799e1">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8fbc1ca3-ad6b-484d-8e8a-63438446e43f">See <xref linkend="sect_A.5.2.1" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_74d1ad0d-70ad-4cd7-838b-35917d6e5e30">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_0b330ccd-ad0f-4b11-a2d6-96749c2a1430">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d61a229d-54e0-4c69-8f32-352f527072d2">See <xref linkend="sect_A.5.2.2" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_92cce609-24fe-4973-952c-3dd5d411e58a">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e576d996-5432-4606-bb6d-521501fe3df8">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_95f7397e-9d1b-4d41-ac05-dde3bde6b6af">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_33b157e7-2162-49cd-9168-e174b75323e5">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8df0f8d6-6667-41ac-a60b-bc49f545ea86">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_acf7289e-ba89-4d70-9135-6667fe3aa80a">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>false</term>
                                                <listitem>
                                                    <para xml:id="para_c28e25e3-7efc-4ea5-ab08-e24aa1b9f679"/>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_922a22fe-f76e-4029-848f-bfbfad81de0f">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_186e1489-2843-4001-a0e5-5ac75ea8c994">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7e5b7a19-a06b-41c0-b5c9-cfad11a7fc81">D<olink targetdoc="PS3.16" targetptr="sect_CID_402" xrefstyle="select: labelnumber quotedtitle"/>
                                    </para>
                                    <para xml:id="para_971c8e7b-bb95-4807-aa4b-96fe573c384e">See <xref linkend="sect_A.5.2.7" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ff02d5ca-3ad0-403e-9cf1-26ca67def43f">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e4b7fda5-fda6-48a2-b8f2-cb792c5a49dc">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_35dd747c-5459-47e7-bd28-a1751a8f90b0">Required if being exported to other than physical media. May be present otherwise.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1e02a7fe-f77c-462c-a538-3f2488454242">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_1a4f1c2b-3949-4f5f-ada3-38d0eeac479a">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8b2c644f-ff02-4d15-af79-4818106a8814">Required if NetworkAccessPointTypeCode is present. May be present otherwise.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d97ec14b-f5c3-445d-96bf-a1b4525fb066">MediaIdentifier</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_07fc2937-a357-4785-ac54-7b0b6c02312e">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_99fa3e1b-35c5-471a-a6df-212e7488b652">Volume ID, URI, or other identifier for media.</para>
                                    <para xml:id="para_69419c59-b28e-4cd3-ae49-38aa700f2c04">Required if digital media. May be present otherwise.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b7d8f65e-6697-4b37-a2c4-c819b7d9b0d7">MediaType</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_3b26c7aa-46c8-4b86-8d8e-dacdb992304e">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_27edc8ac-5166-482f-a2aa-376941b9459b">D<olink targetdoc="PS3.16" targetptr="sect_CID_405" xrefstyle="select: labelnumber quotedtitle"/>
                                        or D<olink targetdoc="PS3.16" targetptr="sect_CID_406" xrefstyle="select: labelnumber quotedtitle"/>
                                    </para>
                                    <para xml:id="para_e2e4ff93-3242-4b9c-8919-eaab8c6b6666">Required if NetworkAccessPointID is not present. May be present otherwise.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="16">
                                    <para xml:id="para_6c89fcc4-f883-44e1-bc1c-b557645364f8">Participant Object: ParticipantObjectIdentification</para>
                                    <para xml:id="para_f982b433-af46-40cf-98c7-af3889802deb">Studies (0..N)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_19daf1dd-bf21-4666-94cd-fa61fdd52d7a">ParticipantObjectTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a6aeee2d-cb51-4fa5-ab08-428fdf7b3b84">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e27d1517-decf-4486-958d-d2cd06ac9578">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>2</term>
                                                <listitem>
                                                    <para xml:id="para_359f099c-294c-4bfa-8e05-7a741bde5ff6">System Object</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5e054260-c177-49be-a2c3-ff9cfa38cce0">ParticipantObjectTypeCodeRole</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_5dab98fb-d3f9-4575-84ac-d27701ae5ed8">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8a5b93b3-bf8a-4f2a-a7c2-0770bb622c55">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>3</term>
                                                <listitem>
                                                    <para xml:id="para_01fdd065-15bf-45a5-8169-6b46471491ac">3 = Report</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_bbf689b7-b0c9-4ed2-a4e5-c3a206b7958a">ParticipantObjectDataLifeCycle</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_53092b69-ea5b-4366-b076-5c380e928201">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_28c98d2e-7978-4ba3-ab9b-7df04cd53463">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c416436e-f9fe-4be9-a772-fd5fbe45541b">ParticipantObjectIDTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_63fb6bc4-10fb-457c-b9e4-f336e2f1e09f">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_546a370b-122e-47b3-a8ac-f9dee307f93f">EV <olink targetdoc="PS3.16" targetptr="DCM_110180">(110180, DCM, "Study Instance UID")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_daab25c6-22ad-4bd2-88bc-265653267f67">ParticipantObjectSensitivity</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c67d6247-fa01-4548-ad16-9e36f43efbc0">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ddbb2b45-4874-4b4e-aa39-db92892ab70f">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8caa2611-702a-46c2-a315-b2b602773ef6">ParticipantObjectID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_18c8f11b-d973-42ca-9f44-5460a183982f">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_20ed1abc-951a-4eb9-8f3c-c0c4d8403bc0">The Study Instance UID.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cef0d323-efae-4dd7-90ee-bee3668240e8">ParticipantObjectName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_43020a9c-6a04-4a70-a0e7-0e7763d6d068">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7af666b9-d033-4a62-b0e3-c6bb23aeb2c9">Required if ParticipantObjectQuery is not present.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c40d72f7-31a7-4598-bf86-98c2f0bfc933">ParticipantObjectQuery</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_960a3348-fa36-42b5-8d46-9f31acdacd4a">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_79feca8b-5a75-4c5d-92cb-fcb6cb886918">Required if ParticipantObjectName is not present.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d8998622-7335-4cef-a29f-9dcf9e0aac5b">ParticipantObjectDetail</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_85d14157-3e78-4c19-b694-9809650ae797">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_246815b4-7a82-42b9-95c0-7c093e176742">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_523ec49c-f3f3-40e9-afe7-c474cce4a8aa">ParticipantObjectDescription</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_5c4d7743-ba00-4e2f-9db0-e6229ff2004b">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_93a11112-5d1a-481e-bd37-eaa83e01489f">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1295569c-b0a9-4773-9455-a47ce0ae6291">SOPClass</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_12731ed3-2323-4ede-afd6-a54d4560d14a">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_aacc2060-939e-4e7e-8e51-efe3d5daf7bd">See <xref linkend="sect_A.5.2" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ade42139-4b93-4eb2-841d-1a1c4b8b35a2">Accession</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_264137d1-5463-4e37-b65b-5cbe87a0d136">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_07407a25-4618-43a2-b4bd-5672f60b8fc5">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_facc91c7-12ee-4a29-8b5d-c5aa1eaa8067">NumberOfInstances</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_5ca6fed7-f71b-48dc-a410-ed32c21f9f43">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1012464e-6e98-4529-a2ac-fecf8d28a3ee">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ecf4d87b-99bb-4924-826e-be537bf41279">Instances</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_1dbc4807-c4f1-4e76-a8f4-05944980b74f">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_26eaa437-7726-4cce-baa9-148bf9c327d3">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c4ec7537-5ab4-4501-b694-21037ee944e2">Encrypted</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_25719fbd-3eb4-4772-95c9-5f1c7c343d1f">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c54426c7-4ee5-47c1-b45e-0830be29a7ad">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_de542a2b-d554-49ae-9981-b246d7c66ec0">Anonymized</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a2f8096d-05e5-4232-b236-8f523ae7735a">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6b0232da-e929-4e44-833b-9402b7216a6f">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="9">
                                    <para xml:id="para_b986f812-886f-4bb3-864b-f17fec4c410d">Participant Object: ParticipantObjectIdentification</para>
                                    <para xml:id="para_286bf3bd-c841-49dd-9340-4d6922769e3d">Patients (1..N)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d46a392b-77fb-4e10-8785-3a4312490c9a">ParticipantObjectTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_95f685c5-0fb6-42db-ad5e-2f1e4363c05e">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2ae5779c-36e6-400b-b5fb-c54bca85eed2">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>1</term>
                                                <listitem>
                                                    <para xml:id="para_12e3063e-8a5f-4a1e-8fe4-0a1d03023a63">Person</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b3021a68-7ebe-4b37-a5b0-c47d5bc84527">ParticipantObjectTypeCodeRole</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_fab0b164-b1b9-46e0-8b73-fe968c7667dc">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4e3398da-550a-451a-862b-b27b9b35dc40">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>1</term>
                                                <listitem>
                                                    <para xml:id="para_7ea02cbd-2c4e-4cbc-93df-65201e6c0519">Patient</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_db7cdc0d-c875-41ab-8e27-56f478cec733">ParticipantObjectDataLifeCycle</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9476fea7-29b5-4b31-a1d3-4ccbfb437b8d">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9dc27e76-0c7a-4284-bc9e-022a80e049c5">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_deae0e1a-4c9e-46ed-a58e-28b1081b810a">ParticipantObjectIDTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_81336b48-cc84-41ba-9545-7f4acd6760e3">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e3712d94-0c6b-4190-a604-13b76f9b8cf0">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>2</term>
                                                <listitem>
                                                    <para xml:id="para_d477fda2-82f1-434d-9755-f06e3d0f9b6f">Patient Number</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_044d7f07-e701-4af2-878a-2f328e6b0561">ParticipantObjectSensitivity</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_007ee94f-6590-4981-946f-2f33d9cf00b0">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a351a6b6-3394-4f5d-8b2e-061f4385619c">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5e5eb3f8-249e-44c1-83c1-40fef945e613">ParticipantObjectID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_d2d73996-d96c-4bd0-933f-6fb26a71c24e">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_781d5491-18f0-4004-9069-5504af149b9a">The patient ID.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7fcd3b75-a8f8-4f04-8242-d8c9c75a1dff">ParticipantObjectName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_1f409197-d20b-4b01-9c96-41d2b1036c4a">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e27f660d-5fe6-480e-b380-92a1ba55811e">The patient name.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_71f5da26-64c0-4641-b5df-2249455c9898">ParticipantObjectDetail</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_89804e36-e051-444e-bdcd-3c2fc50122ad">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7ae9f241-5fb4-47da-8f97-1093d3a85758">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_20e1ac90-9488-44cd-9fec-2a5b0a92cb2e">ParticipantObjectDescription</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_58a02541-0f4d-429d-82ee-e9156f785c2c">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_04de766c-bf32-4f68-bd17-b1b68e654bd1">Not specialized.</para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                    <section label="A.5.3.4.1" status="5" xml:id="sect_A.5.3.4.1">
                        <title>UserIsRequestor</title>
                        <para xml:id="para_e111f2c5-f7aa-4b17-b2bf-93b7e6a81823">A single user (either local or remote) shall be identified as the requestor, i.e., UserIsRequestor with a value of true. This accommodates both push and pull transfer models for media.</para>
                    </section>
                </section>
                <section label="A.5.3.5" status="4" xml:id="sect_A.5.3.5">
                    <title>Data Import</title>
                    <para xml:id="para_2c2f4a07-94d6-4364-b542-e8a005965a70">This message describes the event of importing data into an organization, implying that the data now entering the system was not under the control of the security domain of this organization. Transfer by media within an organization is often considered a data transfer rather than a data import event. An example of importing is creating new local instances from data on removable media. Multiple patients may be described in one event message.</para>
                    <para xml:id="para_c223276e-a1c4-45f4-9169-aa04b8e17d1e">A single user (either local or remote) shall be identified as the requestor, i.e., UserIsRequestor with a value of true. This accommodates both push and pull transfer models for media.</para>
                    <table frame="box" label="A.5.3.5-1" rules="all" xml:id="table_A.5.3.5-1">
                        <caption>Audit Message for Data Import</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_7732c840-aa3d-41ad-985a-d359f6cc9f7e">Real-World Entities</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_66f87d50-c7c8-41e0-9d31-1dd7c4a1476c">Field Name</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_31a5df78-7980-4930-b071-ff9ceb3648b9">Opt.</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_232ba297-fdc9-479c-bd2c-e6fad06f708c">Value Constraints</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="5">
                                    <para xml:id="para_543b9625-6e3b-40d5-af1c-35b943b9b9e1">Event: EventIdentification</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3ae2c64f-26a2-4b2d-97b8-3695b09a137d">EventID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_783a186f-99b9-4dd3-ad78-3f352fb1a532">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_dac17dbe-d529-41e1-b71a-c30ad7c3aef4">EV <olink targetdoc="PS3.16" targetptr="DCM_110107">(110107, DCM, "Import")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7a56229e-dddb-4ced-9e96-2d401b30a22c">EventActionCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_1d09d33e-fa26-48c3-b670-03f6842ed645">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_55f04481-836f-4d35-b377-dad2862da830">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>C</term>
                                                <listitem>
                                                    <para xml:id="para_072d74b9-ab49-45e1-9c52-209a1e0d3f5f">Create</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c17799a0-381b-4550-83d2-3cf463f4f113">EventDateTime</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4154f151-7816-401a-80f2-7a3e6c878fa5">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2ac3de2b-7fdb-4ccb-9c3e-958cc68e00ae">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d80797ec-3498-45dc-ab6a-7152d6216fa5">EventOutcomeIndicator</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_49f98dfc-9f2a-46de-a8f6-c54f53d01e07">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2574e6ec-43ee-4695-b965-82dd1a73a209">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7eac38c5-f541-4745-8381-90f81e3f3210">EventTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9812616d-7a58-4446-8cbd-2802ddc19976">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2a252e44-c988-4599-804b-8c61dba0fb93">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="7">
                                    <para xml:id="para_b198d486-9183-47f9-a0cb-5bb1d699fccb">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_163b5df9-81b8-4b30-bebd-4de48364adfc">Users and/or processes importing the data (1..N)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_39a0dbba-bf04-4358-af96-b289326abd87">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e12412cc-710b-477e-8433-425c030a9c78">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fdad36d3-5172-4100-85e6-94a17590b4ed">The identity of the local users or processes importing the data.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_544eb022-7b29-4144-8e5c-7b12c09d12c6">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4b15b97a-5a76-49f2-9a3d-997716342444">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5a715691-7abe-4469-b665-372d8fa066ae">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_02256111-4670-43fc-92f5-db882d22e7b3">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_97287399-6008-42fb-85bf-66b76d71e472">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0981e0e9-c116-40e0-a00d-b02ddfa70495">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_49fb7aee-d3f2-4561-817b-d6d647abef12">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_421a9d70-7ba1-4593-bd54-442cc325a39b">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9cf85d69-16b1-435e-aafb-0c513f291d48">See <xref linkend="sect_A.5.3.5" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_83c4a260-1752-4ab5-8490-20af3dc470c9">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_25f3c823-c008-4ca7-b816-b8c309a9b188">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_26e102b4-c24b-4cb4-96cb-1c66937a571e">EV <olink targetdoc="PS3.16" targetptr="DCM_110152">(110152, DCM, "Destination Role ID")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0980a155-729a-40fc-960f-eb73c88df4bb">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_fb788720-5359-414d-8a55-0034894c9091">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_551b0d02-6289-4b8e-b98d-e1b7f2870c1f">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c806c805-3368-46c9-97f5-00084cc011bc">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_68168d9d-00f0-4d4a-9ab6-6cc9e61b226f">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2000451b-5632-4acd-8ff0-1f86223ea99a">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="9">
                                    <para xml:id="para_be5801b9-8844-4ec3-a860-8ba5f5992fb9">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_ed3e0bdf-20e1-4262-8952-f10041be78b6">Source Media (1)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_eb511eea-eaf2-4a9c-bcd0-c580f119d83c">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_be3fef87-a633-4020-ac40-cc0d82f657ad">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e82e383f-1746-44a0-87e2-d70eb1526ebc">See <xref linkend="sect_A.5.2.1" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0d7496b8-93f9-4956-a586-690b05f80a87">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_77a63ddf-7396-41e2-a3d8-09088e63c99f">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ba4fd3fe-8a28-4215-ad9e-410398f7853b">See <xref linkend="sect_A.5.2.2" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2da6c1d4-17be-457c-8102-91c785944b51">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_7b2f00a9-5c9c-4e1e-9b17-58d3c1090a9f">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_203a0f1b-5864-4995-a35c-fdeb72754c53">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9823728b-b9ec-44f5-9324-2529d24a5e4f">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_53ae8e15-331e-47e5-a6a1-aba80d6ceca6">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9922da5e-c47a-4ca3-8e60-aa146509fd7e">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>false</term>
                                                <listitem>
                                                    <para xml:id="para_55345469-de5f-4635-a3ef-286aca489b7f"/>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_200aa810-578c-43bc-871f-c5d24ba0e74b">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_bd298d8a-a412-4562-ae9e-ecc0492eb5eb">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_232bec67-bcb7-4585-b601-48f4f2dddbcf">D<olink targetdoc="PS3.16" targetptr="sect_CID_402" xrefstyle="select: labelnumber quotedtitle"/>
                                    </para>
                                    <para xml:id="para_6df4cb9e-a777-4309-b85e-5f076c1bd88a">See <xref linkend="sect_A.5.2.7" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2572c4c7-1849-419a-a3f0-4cfa6efd3d02">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_6786900b-00b1-4e7e-b4bd-6b218921d0ea">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_89538b0b-6b56-4a8e-8eca-f87b44467b92">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5bf467d5-4f1b-4eb6-aea0-557f763e9a46">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ffda41da-6f8d-496b-bf31-0c1d3463fc57">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_94a796cf-1399-4f36-bc5e-e40293e342a6">Required if NetworkAccessPointTypeCode is present. May be present otherwise.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_98863f48-4573-45c2-b6cd-a1d6321804d9">MediaIdentifier</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_18928614-83d2-46e5-bc8f-79c627e4dfcd">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e46f7959-d7fd-4417-ac89-093ba68e59f6">Volume ID, URI, or other identifier for media.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2650da5e-60a9-469f-bda8-a89a4fe647cc">MediaType</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e92e027a-6802-48f1-9d9c-d043a30dbfc8">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6c0c6945-ea89-4d7c-aeb1-832806e8bf4f">D<olink targetdoc="PS3.16" targetptr="sect_CID_405" xrefstyle="select: labelnumber quotedtitle"/>
                                        or D<olink targetdoc="PS3.16" targetptr="sect_CID_406" xrefstyle="select: labelnumber quotedtitle"/>
                                    </para>
                                    <para xml:id="para_8223c426-51c7-41d0-bce8-ba46e7d9439f">Required if NetworkAccessPointID is not present. May be present otherwise.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="7">
                                    <para xml:id="para_a8861984-c712-4082-994c-c0822fa617a1">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_0df97da4-0be4-420d-a8a1-6b2d78e3ba12">Source (0..N)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6394c7c3-d373-41dd-833f-05d5bafbf94f">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2d2439fb-89f2-4b4e-ae10-bf2bc91ba3d6">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_55f56e48-e855-4b87-a537-7e146dc8913d">See <xref linkend="sect_A.5.2.1" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_315b68ed-b419-4246-ad3d-4c6f18065bcc">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_cf8dd8c1-52e8-4f06-a226-a55b9d25de60">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_446ee24e-107d-438d-86c0-f9ae01ca2168">See <xref linkend="sect_A.5.2.2" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5dd18e77-c99c-43cf-bf4d-a357fc021dcc">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_0c8c1590-6b51-41a8-80bb-c534506e4714">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_32630d03-eb66-485d-844a-d3712e1c2287">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3f38ce5f-6783-471e-bffa-5c8bcead7692">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_17321d22-1f37-4da8-8ff4-18601f39f1fb">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_54eb80c5-05e5-4d6e-8056-6d659aa21847">See <xref linkend="sect_A.5.3.5" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9957c70d-5813-4539-8154-6e5768321d4e">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_bf0bbdf7-c372-4957-b8e8-bed3c3eecea0">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_943cd055-65f2-43aa-94c9-75d28fe18f31">EV <olink targetdoc="PS3.16" targetptr="DCM_110153">(110153, DCM, "Source Role ID")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7a72d2e2-b95f-47f7-b0e6-d00c5e0749f6">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_650e9770-5cef-44de-b47d-0191ff3a4b78">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_bebc872b-5a61-4865-b4e3-bdf3549150c1">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_252547c7-35f5-451d-bd41-7c9c636774ff">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_bf917b9d-40ba-43da-bd4e-c42ea056afee">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cbc14479-59d3-4c97-aa99-6e3729207fca">Shall be present if Net Access Point Type Code is present.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="16">
                                    <para xml:id="para_76bf3e3b-efe3-4c83-b7aa-f42239443ed5">Participant Object: ParticipantObjectIdentification</para>
                                    <para xml:id="para_c5024e63-a645-4dd9-86fd-575aa25fad28">Studies (0..N)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_60c6ec03-fdaa-439d-aeb6-d37f51e1db91">ParticipantObjectTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_0d4408b7-4d46-47dd-ad89-7600b404737a">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cd0f96e6-71c0-47e8-9816-afe04456552c">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>2</term>
                                                <listitem>
                                                    <para xml:id="para_d5906bcf-da05-498b-a1df-afdbb4b8246a">System Object</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7b581441-e5bc-4380-b43d-8b72b22e8c5a">ParticipantObjectTypeCodeRole</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_89c70aca-8f0b-4624-ac24-50cd516d6c16">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3b64973c-66ae-4c58-bdc6-937882bf7819">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>3</term>
                                                <listitem>
                                                    <para xml:id="para_94d6dfc1-ec29-4ad6-873f-2e231bca4a7d">Report</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c6cb00e5-6fb2-48bc-bafe-fa5f25ecb5a1">ParticipantObjectDataLifeCycle</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_fbae7945-be4e-4247-8b81-63c8e057b4c0">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_87fed57b-77d4-4cde-97f1-845bfaf229ac">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2dfedc7e-e824-4059-9bf2-2551eabcf5d4">ParticipantObjectIDTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_63b2cb23-2ee1-4d54-a36a-006efdecb057">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3980b371-cb5c-47c5-b5fe-67e15da7ae91">EV <olink targetdoc="PS3.16" targetptr="DCM_110180">(110180, DCM, "Study Instance UID")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b0d7f1c9-e7df-49a2-8f59-431ea4c5ed75">ParticipantObjectSensitivity</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_355df42c-7ff4-4353-8b36-ff68d00cb46b">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7402b759-7b17-4d2b-aa1e-69e9f89a8b84">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_10f67664-96eb-4804-8ea5-4b34977af5c1">ParticipantObjectID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_bc56505f-48d8-4d4d-8acd-c494a5a477b4">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e11ce348-e070-4304-a6ac-cc1fef047847">The Study Instance UID.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e354028e-e0e2-4c0c-aaa3-181f2a975ff0">ParticipantObjectName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ac6a6454-3466-4387-a776-b00e2f56fe4e">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_bd9cc52f-bf46-46f4-b823-53d274787485">Required if ParticipantObjectQuery is not present.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5dfcc745-7700-4ab0-9caa-48020a086492">ParticipantObjectQuery</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_39f0fc43-30ef-4872-89cb-18cbd4cc8d3e">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4bd4ba78-bb03-45e5-ae98-0d8debbb827d">Required if ParticipantObjectName is not present.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3fc557d2-342b-4e1a-b159-67eddeb19a23">ParticipantObjectDetail</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c1e0af67-f8b5-45ba-8342-54d05a98f60b">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_939b4f49-2bdb-4167-a678-c7c93fe5b6b4">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_32ffeaf7-3387-410c-ba01-ef314cfa242b">ParticipantObjectDescription</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8a9d48f8-22e8-4661-81e9-6153985798b9">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3b8d16d8-d822-498a-8eba-2429052b567d">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c058137e-45c1-452b-9313-1bf30c7d7ff2">SOPClass</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_911e4659-1ff4-43d7-9d3f-f10ee2506955">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6af5bb6b-5642-476b-9b20-fe6c384c2c4b">See <xref linkend="sect_A.5.2" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_36a326a8-b2ad-40f1-8ad2-1f473bf041f3">Accession</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ef74384d-68ed-461b-aa83-df1ad6976612">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_378c449c-4b06-4b9d-bbad-a2bf006d5f3e">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0714cae5-b621-4d7f-9832-a316033d03c0">NumberOfInstances</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e7c81658-1cc4-43ab-b5e9-978c493a1d69">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ac0f0ae3-48bd-4544-bc4c-80a761740a2c">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_742abfc9-3bc9-4c26-a160-d91dd5c1bfb0">Instances</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_0b40e505-3502-40aa-9f67-cc0b4bb42498">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e675d3a5-af73-4648-b0bb-82ab27050189">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2dcd3ea6-4efb-4a38-be22-d7447f5b20f2">Encrypted</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8d7a20aa-c4a4-4f4f-8428-6ebf4ee9858d">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_abecbfa0-d05f-44fc-bc6f-a7d2a758651c">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c7e2b904-baf9-4b79-a0a6-2ae8d6c60da3">Anonymized</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ec8db33b-c2f9-4b11-85df-c122ace03128">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_85a64fc4-a603-4691-aab6-d5500b5a564a">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="9">
                                    <para xml:id="para_ad8b8d16-a82a-45cd-9634-22c7ea4861e6">Participant Object: ParticipantObjectIdentification</para>
                                    <para xml:id="para_170c2778-4889-4305-ae69-6a777d64b2b9">Patients (1..N)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f9d6cad6-90a4-499f-aaaa-8766d61a8508">ParticipantObjectTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8e7e093b-3b3d-4ce0-9111-3a3bdb7cfa3a">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9897b47d-cabd-41c1-baf2-a80a0ce7111f">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>1</term>
                                                <listitem>
                                                    <para xml:id="para_6f3206f2-8ca9-4914-990f-90c8039f1d98">Person</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fb7469e4-b7d2-41b6-b8c5-267459407bbe">ParticipantObjectTypeCodeRole</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8e6f6a89-3d0d-4bbb-ba95-60a446f1ecb7">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f636b9fe-10bd-4c1f-948a-b5b01f1f5fba">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>1</term>
                                                <listitem>
                                                    <para xml:id="para_731e50bf-96e2-4f9e-9857-959ff75507e5">Patient</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a5044424-3bd1-4128-af59-c1a98cf71e89">ParticipantObjectDataLifeCycle</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4a8df5a1-11ba-4905-af63-84f84bb3bbb8">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b428affd-a8e6-410d-a95b-aa23e9b7a96b">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ea6337de-f7ac-4a74-84d4-0c12aa26f726">ParticipantObjectIDTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_3c694773-718c-4490-ac9b-34203a35af32">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_63249e80-b031-4bd6-ab2f-483c7b6de110">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>2</term>
                                                <listitem>
                                                    <para xml:id="para_20aa1498-8675-41de-8278-4655a65d82d1">Patient Number</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1f1970fd-be44-4bf5-9bc0-d4f2c80575c3">ParticipantObjectSensitivity</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f497fb5a-bccd-49ce-8be1-210214b26603">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_08b8b532-0e35-4393-93bd-7a65db0ffaee">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f24737c6-2306-4cbe-893b-8f65f4791f65">ParticipantObjectID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_76d1d76c-4b09-41b5-9b18-662d1185908c">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_523be16a-e1f2-4425-ba0b-887b1c9c23cb">The patient ID.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_598e06f1-de19-41d1-b38f-6d5190992da8">ParticipantObjectName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9c8e9140-ae44-432e-a848-d433661e8174">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_faa919e5-0ea7-449e-a518-7f96ad30e8a0">The patient name.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7cebbd3b-fa9b-43da-a314-9ab913ec906e">ParticipantObjectDetail</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e7775507-6fe2-42d8-8de6-2da4c56b5631">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_39c02c96-edd2-40de-bb8b-94a850a24909">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_966827e7-f770-4da8-a3cd-d3b1f1087049">ParticipantObjectDescription</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ab694272-bf53-440e-aeef-7dd190b06ac0">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3a476a96-86e8-4f36-b2e8-deeed37d7a2d">Not specialized.</para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                </section>
                <section label="A.5.3.6" status="4" xml:id="sect_A.5.3.6">
                    <title>DICOM Instances Accessed</title>
                    <para xml:id="para_63d61577-37e5-416f-9f50-59d4a1f4c5ac">This message describes the event of DICOM SOP Instances being viewed, utilized, updated, or deleted. This message shall only include information about a single patient and can be used to summarize all activity for several studies for that patient. This message records the studies to which the instances belong, not the individual instances.</para>
                    <para xml:id="para_7f622f1a-c948-4fce-bf06-0445172f75fd">If all instances within a Study are deleted, then the EV<olink targetdoc="PS3.16" targetptr="DCM_110105">(110105, DCM, "DICOM Study Deleted")</olink> event shall be used, see <xref linkend="sect_A.5.3.8" xrefstyle="select: label"/>.</para>
                    <table frame="box" label="A.5.3.6-1" rules="all" xml:id="table_A.5.3.6-1">
                        <caption>Audit Message for DICOM Instances Accessed</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_11c0e0bc-5e43-4926-9296-940db91a050f">Real-World Entities</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_628286b7-1894-46af-8e72-d7919aeb263b">Field Name</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_3704cce1-00c1-40e0-97ab-b445540b508e">Opt.</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ff158bde-0312-4bf1-b066-0d7e6f24efc1">Value Constraints</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="5">
                                    <para xml:id="para_4cbfadda-9345-4268-b86a-b7c7ddb9bd56">Event: EventIdentification</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d60edc13-a4b8-47cd-acbd-e2471f66117a">EventID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_d772302f-4e63-4be8-99b4-b6142b1eb285">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_50781651-8080-4421-9b3e-9303672cb776">EV <olink targetdoc="PS3.16" targetptr="DCM_110103">(110103, DCM, "DICOM Instances Accessed")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3ac788f0-810c-464b-999e-4e732efbf5bb">EventActionCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_94f0b47a-feed-473c-84e9-f217d053b26c">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5eb05b08-6002-4ff2-920c-aede20266240">
                                        <variablelist spacing="compact">
                                            <title>Enumerated Values:</title>
                                            <varlistentry>
                                                <term>C</term>
                                                <listitem>
                                                    <para xml:id="para_12554267-dd79-4f1b-a785-743e794dee15">Create</para>
                                                </listitem>
                                            </varlistentry>
                                            <varlistentry>
                                                <term>R</term>
                                                <listitem>
                                                    <para xml:id="para_7d9b485c-180d-4d44-9fbd-56de7ae1dcea">Read</para>
                                                </listitem>
                                            </varlistentry>
                                            <varlistentry>
                                                <term>U</term>
                                                <listitem>
                                                    <para xml:id="para_0f23c156-fc17-43bc-9ed2-000b0a7e43fb">Update</para>
                                                </listitem>
                                            </varlistentry>
                                            <varlistentry>
                                                <term>D</term>
                                                <listitem>
                                                    <para xml:id="para_eb749fd9-b810-4a75-99fe-fa254fe0ac29">Delete</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1345672e-88cf-4857-bea8-8c15693c1211">EventDateTime</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c0afa53e-b9fc-4c9f-80e4-4c4f3f56864d">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d77a98fe-22c3-461f-b857-7118e5abc939">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_22d0487f-f50e-4fe5-b3d2-49e2d589e71f">EventOutcomeIndicator</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ba083c36-111a-427b-966b-b72518eef81f">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0772bd28-f652-48eb-b235-6bf476679e35">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0247be14-89a6-473f-97fe-bbd6a9574d22">EventTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_344047bc-f103-44b5-9ba5-7ad02e386cb2">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_71a71e61-cf60-4c32-a0c9-6fbe6199e150">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="7">
                                    <para xml:id="para_2aaf5a32-0122-4658-95b1-02df5d13fcec">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_76ec49eb-6e05-4339-8bae-c0db6a6b778d">Person and/or process accessing the data</para>
                                    <para xml:id="para_8d5f6a25-50e2-40ad-97a6-29b7f1d653fd">(1..2)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6251632d-0afb-41ba-825f-2e523c55d82b">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_d6c410a9-8661-46de-b5ec-e7c85c9f7d0d">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_95d625ac-7f21-41ff-8baf-5efe613d9950">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4273b914-e9a1-4850-ad2e-b6363410da0b">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_1638159e-976b-4353-a7c8-93de13dd7042">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e141d027-829d-489e-88c2-8e4f34c2fc91">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3e6f3d9b-e442-4535-be61-b78410ee2f98">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_dd960437-92cc-4213-9e30-43224d6a36f8">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e71d122f-c1e3-4340-aa56-85fb81a95a2e">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_dce3d8b6-d6b2-4c6f-97e5-f7ae26578eef">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ecdcec80-eb52-4d02-a0ec-a5f499a5d2dd">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a7c2a2a4-ecfc-417f-85dd-ba0981575d3e">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_17d12391-ab36-4edb-9790-5f9ef3e7f2ec">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_3e58a7fd-0fda-44fa-a639-8f1deb5fafdd">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6e4eb45d-d262-4651-ad1c-69fc0dc50c7e">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_54bd41b5-c21b-46ba-94be-8037c5d528d8">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_72ba0680-83e3-4fe3-a0a8-24d8fcbc9149">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_87bfbc0e-5a9e-4914-972d-3218ee50aa2a">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_efd809e7-80ed-4f3f-ae50-8a19ef9361f9">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e8160d2b-ca14-434a-9e81-365beac136e7">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8821ea78-2536-481a-9de3-71c772e64164">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="16">
                                    <para xml:id="para_9eed06b6-d31f-41a4-a7a7-9cb3350ca23c">Participant Object: ParticipantObjectIdentification</para>
                                    <para xml:id="para_dd3b8918-0063-4f35-83de-83d813119ba6">Studies (1..N)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d9813b70-0e8e-4598-8525-8a0d4f8265ad">ParticipantObjectTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_70525768-0b10-4b39-9909-09fdaff0c043">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6ee57ef6-739b-452b-b351-29920d2f6f65">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>2</term>
                                                <listitem>
                                                    <para xml:id="para_3ff78c94-c2aa-4106-a7c2-a0405876c144">System Object</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_32642b05-3ef5-46c0-baaf-e60f4f514146">ParticipantObjectTypeCodeRole</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8ff99dc2-b9a5-40a8-b917-87c55b62a3d2">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_012be5d2-da87-4049-9b1c-ba3d77c073cf">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>3</term>
                                                <listitem>
                                                    <para xml:id="para_7217825f-41e1-48d5-8fce-b59d8db62e61">Report</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9cf68c56-bf4a-4bbc-9ac0-bffa3abf02e1">ParticipantObjectDataLifeCycle</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_63e8d2a3-f9b0-4ec8-9410-0252ccbfe052">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a6756679-a767-4920-950a-f60144d428cb">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d960758b-8334-4894-a452-dd3adc6e6725">ParticipantObjectIDTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2a5d4379-bca1-43a0-8fea-4747781331cf">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_681a4b2c-0afd-4689-acde-abe3487f5021">EV <olink targetdoc="PS3.16" targetptr="DCM_110180">(110180, DCM, "Study Instance UID")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7992c4b9-e38c-4ed1-9149-7c19e504a5d9">ParticipantObjectSensitivity</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e1fa5aec-aa3a-417d-8839-eb29bd7098fb">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8082b0f5-b3bc-45c4-b783-1ea8497fbc5e">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5fa581c7-d13d-426b-b738-562c4fedae17">ParticipantObjectID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_277c14f2-ed8e-4746-b9e6-c18618202795">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cc4309d4-5adf-4c21-934c-13c4c2ad763c">The Study Instance UID.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_945d024c-bb77-4b68-a8dd-c5841b69aeef">ParticipantObjectName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_68f6ab7e-f7f7-44a9-98f6-d2b78795a59f">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b5907d79-b613-49f7-8133-ab07230abf19">Required if ParticipantObjectQuery is not present.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9d29dbdc-6f5f-4ad0-bade-0233a43fad3f">ParticipantObjectQuery</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_1b761046-508d-4d26-8c3e-abcf3836350e">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6070efc1-8b4d-4b0b-b93c-a67ef5db709c">Required if ParticipantObjectName is not present.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1bbdc814-f024-4cfe-a1d3-54520bb3ffed">ParticipantObjectDetail</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ad5a32e3-aba6-4f03-9b53-527e5f5d60a0">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f55a9ed8-a725-4f35-b3c0-d52d88a5d1b6">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e917265d-b985-41ad-afdf-0489e3447401">ParticipantObjectDescription</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9429d391-e6b3-4a90-9e75-16ba15c5e188">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_be857769-91b1-4a8f-9bfc-ffddf77331ea">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9c3b9458-af12-43b2-ba6b-3edc13c6688a">SOPClass</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_027a40cb-67a7-4b6d-b5b7-cb65445313f0">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3d4f2168-01df-4022-a5bd-a14b63cba8d6">See <xref linkend="sect_A.5.2" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_503628c0-1590-49b6-88b0-6a892f29d626">Accession</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_584216e4-4143-447f-8fdf-067f0e980361">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c34145a9-5805-4cd1-a757-a22f3f83fec8">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ae00a0b2-91c6-4e85-a31d-3a08fb871dab">NumberOfInstances</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_949a1560-075d-4947-b108-116ebf1f3dba">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_56cd456f-caa1-47da-a3fd-478bb793040e">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8a2a6ece-5686-4d2a-ba3a-4fa0dd5b77ee">Instances</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e52af99c-b603-4922-838c-5592681dbc8e">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_59196a33-4a1b-4ea9-9634-5a079bfa6c3d">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fb8d3501-0d2c-41ca-9e6b-60c24caaf972">Encrypted</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_77ab95de-50aa-449b-832b-2a12395d6cd8">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a4d17a77-b8cb-4530-8d6a-90ed648503f8">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_42ec3e78-c562-4f9b-8a40-26e76c1fcdd9">Anonymized</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_fa24d0fe-563d-4868-aa96-632cce7b10fb">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8a5c5e8f-2d34-4478-aca0-696d3a83cb01">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="9">
                                    <para xml:id="para_36086137-20ef-4fc9-b916-7abd8b2bd77b">Participant Object: ParticipantObjectIdentification</para>
                                    <para xml:id="para_3acf69fb-da47-49f2-991e-e5b640a1bce9">Patient (1)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7ec13a53-aa79-49cd-a7c3-0bcda716ad4a">ParticipantObjectTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a32050d5-c36f-46d9-a91c-ccb3d965c5ac">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6fae92c5-7b65-4a3a-98f5-691685243edd">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>1</term>
                                                <listitem>
                                                    <para xml:id="para_ff6445b3-7081-4aec-83d1-93d451b165cb">Person</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_62a779cd-65cf-4643-a1a5-e35ce275bd39">ParticipantObjectTypeCodeRole</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_754063d7-75ee-47cb-9a59-79b34cba22ea">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3527b8b1-89e5-454c-b84d-47963429beb5">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>1</term>
                                                <listitem>
                                                    <para xml:id="para_84b8aceb-b3a7-4b04-a81b-e67a7a656724">Patient</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_59d16812-606a-4031-8a5d-7f7ec8dff547">ParticipantObjectDataLifeCycle</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_105267e6-acee-49ac-9f73-e257a29fca44">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e21be082-4b32-412e-a81b-c70d3dca393e">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_10ae5ef1-5999-4bd0-9716-53176b7c92e3">ParticipantObjectIDTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_72bc3b88-e720-4fb9-8921-23a57165fe18">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e5f53acc-273f-495a-bf90-33c8d4c4a70c">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>2</term>
                                                <listitem>
                                                    <para xml:id="para_2daa6dde-1ee2-42fd-a676-8f7859f9c2ce">Patient Number</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e08c9569-8089-4316-bf14-180b7d25b63b">ParticipantObjectSensitivity</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c3eb9c66-4394-4f02-931f-b9a235144045">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9af21396-4477-4288-ab16-fa512c0cd462">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_55c061be-9d5e-4a92-b93b-9fead5ff2b2c">ParticipantObjectID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ed8582b9-087a-490a-8851-dc5cf5f227d0">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_21b8f15a-975a-416e-94f2-ab649b69ca17">The patient ID.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8fa3657c-e5cc-4b93-8d59-f0626d7973f9">ParticipantObjectName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2e620d1c-7430-43c2-834d-2757b5b68f6a">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_27dc29ed-aafc-4a37-91cf-1c9fadd6088c">The patient name.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_60af6379-b53c-40f5-aa85-e2da31505f35">ParticipantObjectDetail</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_5f387080-f834-4396-b2ac-0f591e77dc27">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_530d3b62-f3a4-4575-bca9-b176eb6fd100">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c1b4a40e-8bf1-41f8-a074-0a16c255b69b">ParticipantObjectDescription</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_acd6ab6a-384e-4507-9bde-3bb523927148">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c284fce5-39df-4763-aa8a-e3757cc4914e">Not specialized.</para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                </section>
                <section label="A.5.3.7" status="4" xml:id="sect_A.5.3.7">
                    <title>DICOM Instances Transferred</title>
                    <para xml:id="para_b0690b5a-144f-46cc-86c2-8dbc0560caeb">This message describes the event of the completion of transferring DICOM SOP Instances between two Application Entities. This message may only include information about a single patient.</para>
                    <note>
                        <para xml:id="para_32ae733c-bb2f-4857-8295-063d319c576b">This message may have been preceded by a Begin Transferring DICOM Instances message. The Begin Transferring DICOM Instances message conveys the intent to store SOP Instances, while the DICOM Instances Transferred message records the completion of the transfer. Any disagreement between the two messages might indicate a potential security breach.</para>
                    </note>
                    <table frame="box" label="A.5.3.7-1" rules="all" xml:id="table_A.5.3.7-1">
                        <caption>Audit Message for DICOM Instances Transferred</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c96367f0-6d86-4efe-b8a9-265e6f1ae28e">Real-World Entities</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_1facdd8d-2221-44bf-ba8f-58ff60427a62">Field Name</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_918964ec-d455-4ed3-84d4-937b19c3a35a">Opt.</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_d5c59f48-40b3-42f2-8ce2-18f4842410ed">Value Constraints</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="5">
                                    <para xml:id="para_375065ab-fc55-41d1-abad-379829345e6c">Event: EventIdentification</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e65b399c-9338-4716-ad09-5d052062e4f7">EventID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ad58a90b-b5a6-44eb-a824-a01f9130dba9">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f2f9c1fb-a554-41f6-9168-95d6e507dc8c">EV <olink targetdoc="PS3.16" targetptr="DCM_110104">(110104, DCM, "DICOM Instances Transferred")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7c712bc9-7c82-4c7f-950c-de51cec0dab0">EventActionCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_d844e36d-5e01-4eb4-a785-0cb1004de9cc">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a29795d7-bbf3-4918-b89f-46b53d7ddeb3">
                                        <variablelist spacing="compact">
                                            <title>Enumerated Value:</title>
                                            <varlistentry>
                                                <term>C</term>
                                                <listitem>
                                                    <para xml:id="para_1fcfe233-1665-4a65-8b34-382700090523">(Create) if the receiver did not hold copies of the SOP Instances transferred</para>
                                                </listitem>
                                            </varlistentry>
                                            <varlistentry>
                                                <term>R</term>
                                                <listitem>
                                                    <para xml:id="para_57bf7ac7-64c3-466f-8e2b-a2cd4c6c1593">(Read) if the receiver already holds copies of the SOP Instances transferred, and has determined that no changes are needed to the copies held.</para>
                                                </listitem>
                                            </varlistentry>
                                            <varlistentry>
                                                <term>U</term>
                                                <listitem>
                                                    <para xml:id="para_9267becd-b1fc-4247-9de1-6b1c78666f81">(Update) if the receiver is altering its held copies to reconcile differences between the held copies and the received copies.</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                    <para xml:id="para_2ce8431b-4cc8-4253-b833-480a9c8ecde3">If the Audit Source is either not the receiver, or otherwise does not know whether or not the instances previously were held by the receiving node, then use "R" = Read.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_dd4d555b-46d2-4d78-808f-513a040c333c">EventDateTime</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ee2d083c-e4a0-4a8e-952c-1d72eef7c254">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1aca1dff-9a1a-4136-8acc-f7cdb4d3f11f">Shall be the time when the transfer has completed.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6776c61d-50ba-48a5-bbaf-e7cb7e8e6ed7">EventOutcomeIndicator</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ed78b382-5b57-4c9e-9b52-d45e23a11dc2">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5222f1ca-20de-4ffd-8e01-26b250d6deab">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0b927a48-3f1b-4568-b847-88f059a6fc7a">EventTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b495fc02-24dc-4f9d-ba37-ed435c7fa1d0">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cae9a8b6-da7b-4775-8a85-67df102394f7">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="9">
                                    <para xml:id="para_9df95e29-5712-41c3-8999-73bde1d57f3b">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_b245fb2f-0ffe-48ee-af35-17b5a0367096">Process that sent the data (1)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_daa32c4d-0ceb-42c5-8264-fbcb13e72610">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_0774cc0c-285e-401d-80f3-b1dae11e1132">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b019280a-9697-4223-b136-0fc16d43e76b">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_02583133-8b52-4983-a770-ba7c8fb9e691">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f7a9c75f-f566-45e4-84e2-7afed8b4d358">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f299261c-c979-4054-bcff-1a1b1ae1cc9b">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_94273699-d5ce-4ad4-9497-09041c5447e4">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_672a0465-d892-4d51-b075-c63d1b0e0680">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_36ea3707-1fd5-4c68-be03-f90396083d86">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e4cf5017-0c1a-4b4d-b55d-96c07be32601">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_01bb1c72-3ffc-4f24-b950-79fa07ddb0f2">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3ac5b778-0820-4760-a41e-d4a7fa049eef">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_64bfd71b-1500-4c59-8685-5995a7be5e87">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_6223ae61-1b16-466f-891a-4079198c42d0">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8027f1b5-fd8d-499c-aa1e-192ad7bf6ae8">D<olink targetdoc="PS3.16" targetptr="sect_CID_402" xrefstyle="select: labelnumber quotedtitle"/>
                                    </para>
                                    <para xml:id="para_9a0ed0c1-63cc-47c2-9749-0556b11d083e">See <xref linkend="sect_A.5.2.7" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8e9e8e85-f382-4b8c-887c-d8955c34b692">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_7b226280-e66d-4016-b349-175f28895dfc">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a60d6a6c-e5c3-45ab-8bb0-5436de44bb5c">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ccfa6666-300c-43f8-a786-93581cf309d1">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9e8647e4-71e2-4986-ba4d-c21934acfb9a">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_eaf0480c-e09e-4356-80b1-2353286e4d38">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_767eeaaa-a170-4415-b81f-720b03e9bde8">MediaIdentifier</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_fcf0f782-3de3-47a7-b55c-ec8bb86defd0">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f945e677-bbd8-46a1-926a-aad363a17525">Volume ID, URI, or other identifier for digital media.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_36acf05b-e623-404d-bdd2-93b298be44fe">MediaType</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ea3106d7-dd8e-4805-b311-a1dc4f913c17">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6252928f-ecde-4ecc-99d6-51b125651263">D<olink targetdoc="PS3.16" targetptr="sect_CID_405" xrefstyle="select: labelnumber quotedtitle"/>
                                        or D<olink targetdoc="PS3.16" targetptr="sect_CID_406" xrefstyle="select: labelnumber quotedtitle"/>
                                    </para>
                                    <para xml:id="para_a705e81a-3718-473d-956f-e3c1a2290775">Required if MediaIdentifier is present.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="9">
                                    <para xml:id="para_8b74ad37-71fa-424b-9147-8512e1f63682">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_0da65f0e-602d-4a38-9d22-fe08e15e242f">The process that received the data (1)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1fc28afb-0e7d-4f1c-858c-de7c44a058d5">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2dcd5511-f4d8-4f58-a56d-8b7c940e38c0">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_93fd126d-6ac4-4492-8938-ad72ff683435">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9ff49d83-4dcd-4099-9005-c481b8ff2376">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_47685cc0-7162-4a05-b5b9-65bc392ea1f5">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fb5b1468-0fa4-411f-b980-c421ff7b6bce">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e88a7c58-3325-4560-8b8e-95fb17c06268">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_723a1fd0-5ca3-45b1-86c2-3c2f6c38cd98">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_68faebe3-4ed5-4fa3-9a0f-fef1189fd707">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ab7fc977-5159-4944-82fa-803c72f98e59">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a23f3f68-599f-46bf-895a-5d650ef9528d">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4becc62f-65cb-4345-a68d-7bae681a2382">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_eb711804-7745-4991-89e9-ec5302309b60">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_25951589-510e-4e36-899d-69d9379842ee">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1685eae5-6831-4d3d-80da-107b5bed8543">D<olink targetdoc="PS3.16" targetptr="sect_CID_402" xrefstyle="select: labelnumber quotedtitle"/>
                                    </para>
                                    <para xml:id="para_cbf3c0d8-7268-4fbf-9616-2dbc49d1c1d2">See <xref linkend="sect_A.5.2.7" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0671c4dd-da1e-4b7c-9caa-55e9e3b38f60">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_59304860-3fd1-45fe-8702-5178f72554d9">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_878b622f-9754-490b-b4d9-f1b0d91c7218">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b924eea3-6c57-4ff3-813a-cb9684e6fa77">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_40887b68-60b9-4da5-b712-df95152600e5">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_845a9af9-66d4-437b-8af7-7fc47e2e9f40">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_78b696a9-5d2a-4aef-94e8-fb9b3064f8b2">MediaIdentifier</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_06b5f405-6622-485d-9fb9-1954cbc1e4a4">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5a64a2f1-b438-42b4-8cff-fece0a821d7a">Volume ID, URI, or other identifier for digital media.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a4925db7-6509-44b1-b465-5085c0f16afc">MediaType</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_6a0b1ba1-ee54-43b8-aee7-a274275c604e">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_dfb255e1-d094-4f1e-b148-d3485bc87e40">D<olink targetdoc="PS3.16" targetptr="sect_CID_405" xrefstyle="select: labelnumber quotedtitle"/>
                                        or D<olink targetdoc="PS3.16" targetptr="sect_CID_406" xrefstyle="select: labelnumber quotedtitle"/>
                                    </para>
                                    <para xml:id="para_72991275-5446-4481-8460-1a0020b96aea">Required if MediaIdentifier is present.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="7">
                                    <para xml:id="para_719aa024-ba0f-48cf-8bda-7305b4be4992">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_1a629298-a4e9-4f11-a8e2-c4dcfdfb4c3b">Other participants that are known, especially third parties that are the requestor (0..N)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_91350f59-0719-4818-ae56-1224763c03ff">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2c943b4b-9ead-480e-9108-55ec552bbb09">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_43f89a52-23eb-402c-9fbe-81ab1cae135a">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_81528e13-697f-4b16-b2e7-6b468df8b06b">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8381b417-a7bc-47eb-a4b8-ebce293cbd79">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9fa76bf5-82e1-4e46-89e1-f3a79674eaf6">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a4fff18a-d59b-443e-9caa-a1e9e5eb4ee7">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_431b0d9b-cdcd-4344-9d72-78322268e5aa">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e21acb36-1836-4aca-8da1-e8a723842905">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9f0dd320-156e-46b6-88c5-12b3705aea36">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4ff908a2-4cd9-4ecf-8172-af76cec417b1">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b07e4167-563c-445b-80a6-77319b616d74">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_28e6c497-2550-4a86-944c-e3c8e930b005">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4683c5d1-a585-4679-88b9-5b8e661d1e1a">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a3d8a37f-1059-46e4-bb60-c06ea91a8e6e">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_43e292a8-a1c2-4bec-9d72-2cfc7f789ebe">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_0169d14e-61c8-4822-949b-e2525f2a28ab">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_812d796e-2520-4f24-bb83-b3e78089486d">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d63bc554-b2bc-4317-9b3a-9ef57356c185">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b1dd878c-39f4-4488-9eed-f60a6696cbae">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e8db8344-a57f-40ec-abc9-542e4a935611">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="16">
                                    <para xml:id="para_3c082d94-af05-4e17-8789-8d63736badb3">Participant Object: ParticipantObjectIdentification</para>
                                    <para xml:id="para_f4cac7d8-74a4-4540-ba4c-a8b7ce6af3f2">Studies being transferred (1..N)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e27ff04a-9eaf-459f-b004-23b25465d3a4">ParticipantObjectTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a1750f8c-64f9-4218-b4e1-61d3db8a58e9">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fe5412ec-af8a-4ae4-9499-1155658812ab">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>2</term>
                                                <listitem>
                                                    <para xml:id="para_35b55024-edb3-4c13-a40e-aae877df399b">System Object</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f99fcbf0-8f43-4fdc-a439-0a48ef89c0a8">ParticipantObjectTypeCodeRole</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_86b2002b-1b0b-4a44-b036-6f7b2782d0b4">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_95c90973-2a61-4c6c-b599-77f51f1b8da6">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>3</term>
                                                <listitem>
                                                    <para xml:id="para_822e10e9-0120-4149-a2ac-a7189f22a1e0">Report</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_108322ef-d3e2-43b7-967c-70ee75853055">ParticipantObjectDataLifeCycle</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_adfb9390-5b07-470c-8421-d0cbc63ca54e">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1b8aa4c2-6aa2-432d-bd0d-9ad7dc022b20">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a6d9235f-ea6a-47a7-b8f6-7ca2669ac11a">ParticipantObjectIDTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_44ba967a-6e7a-4a5f-923d-695bd871a032">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_99d1a89d-96f4-458e-84f8-8f8b4b2892d0">EV <olink targetdoc="PS3.16" targetptr="DCM_110180">(110180, DCM, "Study Instance UID")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6672191e-4cad-4310-aaaf-d83d498f1b55">ParticipantObjectSensitivity</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e4640095-60ba-48ba-a654-58fb25a0bf12">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_64314a59-2b3c-4be5-9f2c-1bd155281780">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8e4d8a35-9b1c-49ab-9861-9c22e852b87f">ParticipantObjectID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_d0641e9c-ed76-4064-985c-2181ae2932a3">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_dc072a33-2272-42a9-8761-39d6841f1294">The Study Instance UID.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ce5dd9ed-2c16-4ff5-9895-53b62cb20cd7">ParticipantObjectName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_12fcf52d-8fe5-4a51-9ba7-8a168092a5fa">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_de51d79c-cc91-4318-bc46-44197debdf60">Required if ParticipantObjectQuery is not present.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_de5fb5ba-1dc3-4aff-b1b4-2a6abce1d8da">ParticipantObjectQuery</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_0af55643-f3f3-422b-a130-d7688dd4d59a">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7d6ba474-7ccb-47ff-9cec-35adb3b033aa">Required if ParticipantObjectName is not present.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3a01fd2e-a7b9-40b5-8343-162659401973">ParticipantObjectDetail</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_037a44b2-6328-4e53-b099-f490f99e2f8f">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1cdddb30-ad88-4f4f-856f-a3b8d2efb864">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_635360db-74a4-47c9-93dd-f52165e658d7">ParticipantObjectDescription</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ca7b8ad5-5ca9-4f8d-9661-b73bd3242146">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_94dc4320-e4f2-4edb-8877-2c49bda746a5">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3459de15-a161-4f42-929b-9699b6ce92f7">SOPClass</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4d41aafd-8c24-4cbe-b9ab-5a6b352a03da">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_34d0db37-6124-428c-8abf-ac4261c74bbf">See <xref linkend="sect_A.5.2" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f9e4c4c4-2e79-41e5-89d9-f9cbbd9f0b72">Accession</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_890d7432-b974-464f-9475-00c41da077f6">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1238b333-af7d-4d27-a860-d5170f6be134">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_54990f18-f739-49a8-bfea-42b4c54f85dc">NumberOfInstances</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c2003550-2d17-4151-9af0-3538f31892a3">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_787fd9b2-2d58-45a8-8f75-208776892de1">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e47ec9c5-4ad1-4d94-a81b-df4cde366608">Instances</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2932038b-6aa7-4c50-acb8-211c6c63d3be">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_48cbba47-9c19-43ac-98d0-3762b7de074b">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fb33c3bf-0d83-412d-8e1c-a5a9a16a8bdc">Encrypted</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_bf6a1c2a-4499-4c03-b463-c2c901a0e922">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ee3dfd7c-2069-4ad8-b9e9-e97764c98d16">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_191dd8aa-28c8-4a69-9f26-96400b64e62b">Anonymized</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_7290af1c-38aa-4559-a983-88cfb43c490f">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b486c084-f4ab-4f7f-a29e-af64edce6964">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="9">
                                    <para xml:id="para_ff138cab-d7ab-4f22-a7da-7f19706c6455">Participant Object: ParticipantObjectIdentification</para>
                                    <para xml:id="para_01992446-0530-41ca-a60b-edaf37be5c01">Patient (1)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0f30974a-75b8-4a25-bd01-ab002aa128af">ParticipantObjectTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9206656f-d5fb-4ef1-be83-b4f94f16a4c5">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_67a0073c-f4a9-4aca-9312-85aad6d89079">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>1</term>
                                                <listitem>
                                                    <para xml:id="para_d7b62799-f308-4e12-9308-2991930cac4c">Person</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d73e1678-1918-4efc-984d-1712a9f93601">ParticipantObjectTypeCodeRole</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_1340fe88-7ebc-41a0-a6c1-dcb184865816">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4da36a1b-37cb-40da-9c04-3d190e322843">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>1</term>
                                                <listitem>
                                                    <para xml:id="para_db78d2bd-65e5-440d-9217-fde803e9e302">Patient</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_39321713-e71a-4f27-abac-76c1cc85cf93">ParticipantObjectDataLifeCycle</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4f9ca157-ea0b-4766-8d5d-73520a9dd67e">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6ac6386f-4585-4e40-879f-d525e2ac38b7">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6f895bff-69f6-4175-8b44-79bc6a5ed517">ParticipantObjectIDTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_16699810-9436-42ff-91c8-a67133078b7a">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_25a13784-96b0-4c01-899f-8ee90d83729c">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>2</term>
                                                <listitem>
                                                    <para xml:id="para_5878c177-7bfb-4d23-9535-1e998570964d">Patient Number</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e2aa15f6-7477-4689-a93d-94aa3afe32ef">ParticipantObjectSensitivity</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_29a811a3-1e89-4f44-93a4-0e57fb46d0e1">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_94e6bfe1-8979-44a5-9835-97fadd8e6105">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_919c501e-3787-45bc-9200-501bfdf159f9">ParticipantObjectID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_cc906189-fd7a-4765-86ed-dbf8b43a1167">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6facfd6c-cd85-45e9-8116-075c7f169529">The patient ID.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_692d65b4-0d7a-4ba6-9796-def8f6456412">ParticipantObjectName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9c28b5f1-67d9-4b84-ae62-8a6133776b26">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f1608c66-330f-426c-93af-a7cd51bfa0b8">The patient name.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_024ad278-cb7d-4362-8c2e-9d0cb6fffdac">ParticipantObjectDetail</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_1fe6742a-e4bf-4aeb-b5fa-8ea851000e65">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b2332112-89cf-4ded-90c1-4c8dc5948b7a">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_071b473b-77ba-442e-8422-6a356ce97b95">ParticipantObjectDescription</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9af0f774-e4bf-482b-8d67-a5fa1267d474">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3b0609a2-501c-4793-b2cb-989ff9da0d6d">Not specialized.</para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                </section>
                <section label="A.5.3.8" status="4" xml:id="sect_A.5.3.8">
                    <title>DICOM Study Deleted</title>
                    <para xml:id="para_836fbee0-8bf6-4226-8580-8905743bed30">This message describes the event of deletion of one or more Studies and all associated SOP Instances in a single action. This message shall only include information about a single patient.</para>
                    <table frame="box" label="A.5.3.8-1" rules="all" xml:id="table_A.5.3.8-1">
                        <caption>Audit Message for DICOM Study Deleted</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_edc56167-b1c9-492d-9ef8-00c2e18cf650">Real-World Entities</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9c204fc2-d331-4201-b695-5b19262bf520">Field Name</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_dde58f8e-bff1-4097-8080-9c2139dcd8fb">Opt.</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_0e338c6d-a96b-433c-9af8-952574596e99">Value Constraints</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="5">
                                    <para xml:id="para_c689b273-48b5-4d1f-9ce3-cb59f8f5954a">Event: EventIdentification</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0b5e0dd5-6b04-4505-8a73-b00cc85fe04a">EventID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f84c10bb-2c19-4107-9320-049ad841fae9">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_33d2f973-0f3e-48e5-aa85-f387a6077f63">EV <olink targetdoc="PS3.16" targetptr="DCM_110105">(110105, DCM, "DICOM Study Deleted")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b5260dd2-a329-45bd-88b4-2c940e4a82c2">EventActionCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ee200bb4-b618-4ea9-951a-0a396059d40a">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_97d0a540-7304-4752-9500-5bc8019da846">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>D</term>
                                                <listitem>
                                                    <para xml:id="para_beac0177-31f5-4a06-8cd5-c6407d1e8195">Delete</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2a8bd00b-fa9e-4118-9529-2f47f6fd6ea0">EventDateTime</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_728c4a9d-475f-440e-8c9a-0016c68b14d2">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2d27bb77-2a99-46fd-90e6-a4636fe747ca">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ce9f5186-49e6-4a54-acf9-b99f4f61163b">EventOutcomeIndicator</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_fdb59ced-a7e9-40b2-a554-4221ff1f04ce">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_505d50f4-6bff-4f69-a41a-d93d6cc54d52">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8ac00e60-fddc-475c-9823-4419dc10374a">EventTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_87926773-119f-4204-9724-69ea67598910">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cc684645-eec1-4e64-bf9d-dc7b632006d0">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="7">
                                    <para xml:id="para_655c8070-9971-4e06-908d-5025aff28616">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_99251329-0d7b-41db-a251-8699b6d6efa9">The person and/or process deleting the Study (1..2)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_74720543-f28d-47a0-9821-25c238b07106">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_0273e3ec-67ec-472b-b7fd-5b7c234e4a02">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b5fc807d-b59b-433a-b0b9-5ba6fc2bf56f">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d0961d81-e9f7-40c1-9256-4d7416ca0bc1">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_39f9563d-d894-446a-9407-1dde4b2c5bc4">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1211d606-2667-4942-9d4f-5c3765292723">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_83883f3b-ffb6-4e60-851a-b984fb5cd86a">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_5d91bc1c-8b69-467d-868a-1ce479c7b8cb">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9ca6c4df-4967-4332-8752-41678cac682a">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ee9bc5ff-e97f-41e1-b8ab-cd47ca99a5eb">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_276784d0-e1d3-4b0f-bafe-408cdddc4cfa">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a9e7c37d-a47e-498f-8e80-55c9be96c65d">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fb0986d8-97c5-43ec-aca3-0f25118c0608">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a87a2761-57e8-4331-a059-2382239af378">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a2197cd9-f08b-4868-998a-7d55594dcd87">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cef8943b-ffdd-4273-89d6-6a91056681ac">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2f7adeb3-a552-43fc-8d3f-bbba11ba891c">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1882e8c8-9531-476c-bb6f-e5d4cc642b14">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c1eadbf9-5274-47cc-ad12-714b5a441301">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c19fd686-c9d9-4fcb-bcd1-56cbfd8337d8">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c6440ba1-7f1b-447d-96bc-de33155ec70f">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="16">
                                    <para xml:id="para_0a16a39e-2df9-4ab0-9a39-109ab7274af4">Participant Object: ParticipantObjectIdentification</para>
                                    <para xml:id="para_811e72b7-3bc4-4043-aed3-2ead33ea10a1">Studies being deleted (1..N)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_049d41aa-ebd8-4cb0-8824-b2bbded267fb">ParticipantObjectTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8dcbd977-6673-4d8e-972d-56165aeeda15">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8aa30896-6a7e-4fc3-98fa-0eaca0a01f1a">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>2</term>
                                                <listitem>
                                                    <para xml:id="para_77945837-616f-4eea-a084-f7b96cbf5a40">System Object</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1a67296b-92d1-4e74-b6e0-ad20328f5df1">ParticipantObjectTypeCodeRole</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9cafbd90-16bf-48ec-bae6-7ad82f50230d">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_52810bc2-aa0c-41e3-baf2-39ba1d8c2f25">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>3</term>
                                                <listitem>
                                                    <para xml:id="para_85c57e85-410c-43db-ae45-79905e1206a5">Report</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_07e23138-48fa-4708-97cd-52103275eb8a">ParticipantObjectDataLifeCycle</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b3faf87b-87b8-4caa-8e29-0a3722f2e32b">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b3d84e5c-4366-4916-b2ac-e1c4a204e85a">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1dade891-0c50-4a1b-8caa-647b99d13409">ParticipantObjectIDTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9daf6086-50f6-466a-b46c-7fa9c0f9a8b6">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_998c27bf-1127-4aec-9f13-6beb75a91a4e">EV <olink targetdoc="PS3.16" targetptr="DCM_110180">(110180, DCM, "Study Instance UID")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cc8ea261-44ad-42c9-b078-9edc3688aa50">ParticipantObjectSensitivity</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_df804439-8710-49c8-ac32-76b93a830149">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d2f5f2af-5f27-45c3-bb8e-8dd7489d7a19">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c6bcaf09-7823-4451-95af-2295cc10f254">ParticipantObjectID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_35839288-fc0d-4123-9d32-a5b2233f0912">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b68d2d74-f3d9-4252-a9e7-f87413cd8e9d">The Study Instance UID.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3761558f-8730-4c8b-9fda-f3e2e2a597a1">ParticipantObjectName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b76a4dd4-5976-403e-b608-aa5c487c1015">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6c8d3e25-6103-441e-b903-db7840844a0f">Required if ParticipantObjectQuery is not present.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d206e234-4fbc-42d4-9462-ce09fe9a29af">ParticipantObjectQuery</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_fb06be67-1c37-4c84-b094-8501f11e4818">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b72ce2da-02b3-4bc5-97a7-412314c29891">Required if ParticipantObjectName is not present.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c15643c2-10ba-44ae-9ef8-11ad31c13a54">ParticipantObjectDetail</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e59d5c5a-0fea-41d8-8eef-15a9cf5d993f">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2ad14228-33ef-40cb-a239-58a10a41b99b">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_dc9e5a11-30ca-498f-8b21-bb2796628569">ParticipantObjectDescription</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ddab2816-dd26-437d-8288-e334ae2a7472">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1313aca8-32e7-49b2-813c-c157210907c3">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3ab5d5e5-edd1-474c-a96a-68c3a40b429d">SOPClass</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_88137660-2f1c-4f2d-99e3-d5b059d35b5c">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_75b02375-0b7e-497a-bcf1-2a70e65405e8">See <xref linkend="sect_A.5.2" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_eb128989-927d-4f29-bec7-053e5a3f7c65">Accession</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f622c7bb-b5bf-48c0-a227-4c112e349a89">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9b8df242-03d2-40cc-bd71-d0d8c9fe7cf7">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ca2ee8d4-11a5-4e6a-ae08-e650f12629d9">NumberOfInstances</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f59b342c-b35e-4d93-8843-e3f9f614d652">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_487a7776-45a8-49b7-ad28-30a809a1c8a3">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2b09dac2-5a4b-4a1f-ab18-f0f72d89804e">Instances</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_fe9a24dd-c697-4e9f-928f-5a285dc56025">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_97578024-19ad-459c-aa62-8ad867efb604">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d102476f-b79e-4ac2-967f-f7b312ac14b2">Encrypted</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b39639b8-0a2e-45dc-a0f1-68aa60d6d781">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e68fc494-aea6-4f6b-8642-fd703db3f6ed">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ae01633c-55b9-454c-b6fe-a53ef1186c1d">Anonymized</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_01d7991e-a751-4a1a-a129-afbd7ca4646c">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_12a3018e-b55a-4d78-8e17-84949a2e7ff6">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="9">
                                    <para xml:id="para_1f222287-661b-4db1-ab8c-87534fb59809">Participant Object: ParticipantObjectIdentification</para>
                                    <para xml:id="para_53c4acbf-012e-4f13-bd36-232c7f32b041">Patient (1)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_07a50344-38ca-454f-8523-96d5ac806e0e">ParticipantObjectTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_6649396c-b604-4a87-80d3-5c1b41728eeb">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3e45b745-fb50-4d53-88f5-669c7a99191a">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>1</term>
                                                <listitem>
                                                    <para xml:id="para_e1bfe8de-f420-4ede-8f1b-6dc21d697a76">Person</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_eca32767-78eb-4732-bd6c-237be36cdc1e">ParticipantObjectTypeCodeRole</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e8037621-bca2-4f40-96c8-056400d23654">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2002f7ae-9ecd-4eea-83ed-f3cdfb2a1f1c">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>1</term>
                                                <listitem>
                                                    <para xml:id="para_5d44bc3a-aa58-45e9-a706-4babd08c1b20">Patient</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d129e35b-e7fb-4016-aeed-90b566adb5bc">ParticipantObjectDataLifeCycle</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_12c0eb8c-5526-43b5-851f-e79f8787a365">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_297f8acf-a31d-4a84-9960-667ad89dd91a">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b0b85cc5-6e0a-486a-98d9-e248596f9fba">ParticipantObjectIDTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8d88aa29-1022-4b17-96b5-8712f5207521">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c30ddd6b-26e2-4f05-a4f7-16362060f9d2">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>2</term>
                                                <listitem>
                                                    <para xml:id="para_d810dd2a-126a-4092-98e6-9af5810ba6c4">Patient Number</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0fcf2866-7d77-4f8f-b773-87b5b50dc7f9">ParticipantObjectSensitivity</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_62f741d4-78a1-4a7f-b982-72c5934f9967">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c6563f51-4aac-458d-ae43-833414f5fb3a">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_30e5e85f-cafb-4b5f-b1a6-163fe6da82b4">ParticipantObjectID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_23cf6f17-6790-4029-b942-7a83d67f4101">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ddce20ca-3ae4-4425-af37-b43c9668d406">The patient ID.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_31e0fdd9-2295-4084-b783-3d0e85c3acda">ParticipantObjectName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4038f6e7-52ac-4e1f-99fc-127d56b6d9eb">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_04d13900-d71e-4310-a34b-0bc15bacfe2b">The patient name.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a456238b-c685-4fa4-b06d-55d87f61ce2e">ParticipantObjectDetail</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4adce941-aa91-4e7a-b998-9259f4afda6c">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e91b0030-5848-45a8-9b31-fbe69a10bbce">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_dbda3a02-c3a7-48c3-92f5-91afdf54bb37">ParticipantObjectDescription</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_6905a1e9-aad8-40b0-8814-9a66ff1be6e9">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_82dddfcb-c373-45f7-b0dd-1dc7501dd73a">Not specialized.</para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                </section>
                <section label="A.5.3.9" status="4" xml:id="sect_A.5.3.9">
                    <title>Network Entry</title>
                    <para xml:id="para_1eac635d-f5f6-46f6-b206-76eab1a7e601">This message describes the event of a system, such as a mobile device, intentionally entering or leaving the network.</para>
                    <para xml:id="para_29062bd3-1274-4b49-a9c3-30703eb40aef">No Participant Objects are needed for this message.</para>
                    <note>
                        <para xml:id="para_1bb89459-b03d-467a-aeab-0a8bb3f266db">The machine should attempt to send this message prior to detaching. If this is not possible, it should retain the message in a local buffer so that it can be sent later. The mobile machine can then capture audit messages in a local buffer while it is outside the secure domain. When it is reconnected to the secure domain, it can send the detach message (if buffered), followed by the buffered messages, followed by a mobile machine message for rejoining the secure domain. The timestamps on these messages is the time that the event was noticed to have occurred, not the time that the message is sent.</para>
                    </note>
                    <table frame="box" label="A.5.3.9-1" rules="all" xml:id="table_A.5.3.9-1">
                        <caption>Audit Message for Network Entry</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_eb520ab8-e4a1-4eca-81ff-df8e61253ed9">Real-World Entities</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ccf7b844-9018-4f6f-98fd-46906be38c3d">Field Name</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_5ef37a9e-5dd3-4253-9f2b-c80c15fa3748">Opt.</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_dd9190a4-35a9-43d7-96ab-10cb50200cfb">Value</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="5">
                                    <para xml:id="para_7f862969-5e51-4513-a230-a88b5e19acce">Event: EventIdentification</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_adfe1b29-faa2-40ca-b8f8-bb0c1f648868">EventID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_bfe44196-4aee-4412-8a3b-5418403ef8d2">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a22b7537-7613-4530-914a-5bd9311f3692">EV <olink targetdoc="PS3.16" targetptr="DCM_110108">(110108, DCM, "Network Entry")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2e808b46-437e-47a0-be9a-455d31d2963a">EventActionCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9e9c0a60-0e45-4a1f-ae76-82797f5e7fc2">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_795c6ab9-207a-4272-a349-be467396df27">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>E</term>
                                                <listitem>
                                                    <para xml:id="para_42660034-b6b6-43cb-83bf-f149ac0b9191">Execute</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_028c635e-6092-4529-a069-8683523a36ef">EventDateTime</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c23c574b-dd3d-4058-a6da-64762a042222">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e8b6cb6c-f26b-4ff7-ba1b-8186a90b831a">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2804c10b-2154-4d9a-b62d-11ccd5918e82">EventOutcomeIndicator</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9e5ec98d-9611-497a-b20f-d30579ba6c20">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_299118a1-1c34-4c56-aaf3-6a56ae3b9671">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9e62a4f0-ae19-452a-8a36-6a7c8fe6481f">EventTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_10a8b0ae-ff87-4a87-8f2a-ebe00e42bea6">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b97d41d7-ccc4-43be-bbee-ab12df8039f7">
                                        EV <olink targetdoc="PS3.16" targetptr="DCM_110124">(110124, DCM, "Attach")</olink>
                                        EV <olink targetdoc="PS3.16" targetptr="DCM_110125">(110125, DCM, "Detach")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="7">
                                    <para xml:id="para_4874931e-1257-42cf-8f46-71f7e7a21763">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_7f2aa0b7-30db-4443-9992-26c2fc15ff13">Node or system entering or leaving the network (1)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_abb34c6c-01ba-4e64-856d-f1311ae74c84">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_12a8d15c-5c20-4c74-a638-3d9e6ef9f4ae">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1bb9b8ad-4d95-4f70-82dd-6a701b349cca">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e7f82e02-b4c3-4126-b758-bb5e6820f6c5">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2b685a52-14c4-4226-8d82-3d8b7a5b6d21">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f3c77709-08bf-49b7-9bee-5c19988cf4c4">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_59ad6a47-a9a2-432f-8cfb-21328d40b6c1">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_6e26ea77-2605-4d63-8b89-d95ea61001fa">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8ed27dd0-93a4-4759-8aa5-81fc0719672a">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_028f2f4e-f457-4778-abae-5346d11f0f5d">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_3bcc7301-9dca-4199-bff1-953d8cc3fecc">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cf70ce4a-34c5-458a-9d00-fc5cb8c6d199">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>false</term>
                                                <listitem>
                                                    <para xml:id="para_71306d07-7079-48ea-b9b3-e69da75529fd"/>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a1d4e8b1-56c6-4e9e-9196-8067c1963365">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_d66b27f2-a488-4b29-887a-5516648318a0">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ef1626a3-21ef-473d-bdd1-59fbea16b092">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_65a6e84c-925b-4621-a905-ae4a3dd14f00">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_bea32171-e5c1-4cf4-9187-2fc9a12a28da">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1696ed33-9a8c-4c0d-9c78-4b0f41be828d">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5b199715-6056-4e22-a419-720a2c8ae3b9">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2e4ff524-cf8d-454c-ae61-4b9ca0ec4ea4">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_64839792-1fea-485d-9355-91c02458d847">Not specialized.</para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                </section>
                <section label="A.5.3.10" status="4" xml:id="sect_A.5.3.10">
                    <title>Query</title>
                    <para xml:id="para_1618db52-56f5-4556-af32-4741203d1a31">This message describes the event of a Query being issued or received. The message does not record the response to the query, but merely records the fact that a query was issued. For example, this would report queries using the DICOM SOP Classes:</para>
                    <orderedlist numeration="loweralpha">
                        <listitem>
                            <para xml:id="para_520d0407-bbba-4401-a0b1-b3fd86e23ca2">Modality Worklist</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_f6530434-9c54-436d-a9d1-29ec4163c738">UPS Pull</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_c491e402-7b29-419c-8c8b-9b62177ea473">UPS Watch</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_9fbebace-1b76-4726-86e5-c70087476834">Composite Instance Query</para>
                        </listitem>
                    </orderedlist>
                    <note>
                        <orderedlist>
                            <listitem>
                                <para xml:id="para_281e47d2-0107-4acc-bcad-e4c12a607976">The response to a query may result in one or more DICOM Instances Transferred or DICOM Instances Accessed messages, depending on what events transpire after the query. If there were security-related failures, such as access violations, when processing a query, those failures should show up in other audit messages, such as a Security Alert message.</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_e0328e27-76e8-4367-a642-d5e963ac5899">Non-DICOM queries may also be captured by this message. The Participant Object ID Type Code, the Participant Object ID, and the Query fields may have values related to such non-DICOM queries.</para>
                            </listitem>
                        </orderedlist>
                    </note>
                    <table frame="box" label="A.5.3.10-1" rules="all" xml:id="table_A.5.3.10-1">
                        <caption>Audit Message for Query</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_fe769432-89fc-4614-8541-c2d8b55bc745">Real-World Entities</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_60e82350-415f-491c-b400-2cd24a62aa30">Field Name</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_3c0aac7f-c3ec-4a40-998c-872bf26a2763">Opt.</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_d291c3fd-7f2e-47fd-b6b7-804fa4297346">Value Constraints</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="5">
                                    <para xml:id="para_7ad1941e-5d70-4c3a-a0fa-e62ad1943188">Event: EventIdentification</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_441a51fb-e45c-4ec0-b06d-f1d5257b7b35">EventID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_1834d3c7-5562-4295-b5aa-3fa922361a33">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d6cba1f7-0f12-412c-82a1-f1488d90a0e5">EV <olink targetdoc="PS3.16" targetptr="DCM_110112">(110112, DCM, "Query")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9dda3bf4-01a2-4c3c-8caa-f0210891b9af">EventActionCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c53a288b-b98c-4468-b327-70f95cb84d19">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a3ad1f5a-0984-4aa8-992f-47b1cdb21ee9">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>E</term>
                                                <listitem>
                                                    <para xml:id="para_a4dadc21-4591-496f-9c9b-24b86a29c1f2">Execute</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_222d9c4d-4bc5-4942-aded-194fd128477d">EventDateTime</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2973d980-274d-4038-9efa-ee0da6656a9d">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7e6b99cb-1c76-425c-ade1-4ffc05f9f94f">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_57553755-e196-446b-91ad-75b8780bb9d9">EventOutcomeIndicator</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4dde004c-775b-49f3-bff0-ff98fc5c9242">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_52470904-fdd3-4bdc-aff5-00c1a83debe1">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_15059f18-2e36-4a4e-8017-581ec4fccd99">EventTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f1370262-119a-46aa-81dd-c77a9e60c7cd">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_afa33a96-5790-4ec6-969b-ed9622dbc16d">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="7">
                                    <para xml:id="para_534912b3-000b-480f-8a7e-071951e5f46d">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_eb1ac32d-855c-45ba-824b-692ee2d373f0">Process issuing the query (1)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_60c10c83-07a5-4ba6-a733-5419a1e8ca82">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4d7972e3-b541-4f7d-b7ed-c19c22f0652d">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d027a146-820c-46cd-8e6c-9fd36f54d75e">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f9388f9c-1e42-4bf5-97d5-32c6e2a0a243">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_3f1785f3-045a-494c-986c-620fca82d662">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b4581bc0-5f91-4520-9a4c-17eb8e304eb9">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_69b56506-af4e-47f9-a398-70eace64784c">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c2322c00-8e93-4ed7-96d1-dbdc89da02bb">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_58c53916-294e-44a6-ad9e-06b99918bedb">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b1c6894f-932f-4b34-a3aa-dde2794ec7fe">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_3daa60e8-a859-4016-8e83-3bb8f24fc2ee">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4768f3a1-6f74-4035-9ddc-e59e5bda9e02">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_173dadac-52c4-474b-9388-c8e642b9b03d">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_3118387b-8510-4b54-8e7e-646aa76b214a">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c459b004-300f-423c-b2ed-e3e1c63a3b65">EV <olink targetdoc="PS3.16" targetptr="DCM_110153">(110153, DCM, "Source Role ID")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0ebc656b-a6e9-4ea1-bea8-c3e79d67ee30">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_49eb1219-bfaf-4c23-8ff7-c427fa7500c4">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b00ade6b-9aa2-4f85-85a5-2a0d93cf681e">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9015ef6b-2db9-479d-b2ed-7f4019c25132">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_11dd7620-d0b6-42d2-9a32-5bf594f3094b">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c3cc3ae8-6eb9-454c-aa40-d20868a7a93e">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="7">
                                    <para xml:id="para_1af21df5-f10e-49df-af28-41b15cddb137">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_792d6a1d-49e4-4b61-90f5-d41054ea40fc">The process that will respond to the query (1)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6555bc66-9f39-4ee3-a7cc-bc095a7d156c">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b5f8487a-fcae-4d0b-b22f-8574cf2317b3">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ca4477f9-aa03-4e27-8612-3a51221ff66f">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1f45dc91-b36f-4b9c-88d2-a5952749d0e7">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_205ff29c-e327-4b46-a657-d4e0123316f8">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_46187235-c81b-4e62-b51e-32cc88c10087">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_bdce354f-034f-4043-ba48-d96034b70239">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_43ddb5e7-be99-452a-9794-1501ce839e4f">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6ad0dd66-b290-4eda-9737-9fc75dc3e30f">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2f1895dd-2093-4f5a-b841-1cf19ec15504">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_53cb712c-785e-4233-9279-9bae25171726">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7efdb35c-883d-4616-b752-43a3f994aa74">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4ed1bf9b-2bb8-4180-b7ec-bc23db44d773">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_be098bce-e4a5-4414-9ba2-484f33415777">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_44c3f53d-f23d-48d2-9a79-ddf61372a74b">EV <olink targetdoc="PS3.16" targetptr="DCM_110152">(110152, DCM, "Destination Role ID")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b006dcc8-f915-453f-abfa-c4cee4efdeb9">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9976cf07-19e6-40ef-8246-e1b0ea9746d8">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f035bceb-8ea1-4630-8d5b-c0265f81b987">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_eeb97a34-bb4b-48f8-91e4-c6eff16003f2">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_bdbf9fdf-67ba-4edf-aec7-dd9754580246">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1ad524da-1190-4779-8e62-4de9c749311c">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="7">
                                    <para xml:id="para_40aefa8a-bd97-4877-a0dd-d041ee633618">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_cff7d42d-e03f-4de5-a410-ab11821a2b96">Other participants that are known, especially third parties that requested the query (0..N)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ba0f6293-d43f-470c-9ae1-2bb3c1c3f304">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_1e166133-3747-42a8-b545-ea42d916b87b">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_64097029-19c5-4a7b-be72-aed2885db7d9">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9f8bc2ea-df6a-45a0-9bb2-21e2b8557122">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ef6834a0-bc82-4f81-a693-fb45426af8fa">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_214cb50c-709a-4b3d-85f9-d783d13c4b2f">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8e1c635d-2548-49b8-b17d-fe0ac49f4ba9">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b9256850-c2e8-4992-90a8-d23cab0d6990">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c49c97cb-e57f-4ec3-a428-c74b44ffa4d3">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5e3ff602-5072-4dc5-bfd9-3e43214f6d0c">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c559d54f-de85-45f6-8ca9-2d14032ecf5a">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a7352bae-c7a3-4009-bdc1-ae716f018293">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e4713f5d-100e-4f8d-9a85-f4fc91a0c957">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_89086f8f-d5ca-45c9-96dc-117bb4c5ac55">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0f593b48-5068-49ae-b46c-f6f855d5a114">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_81a22b0c-ca25-40db-9a37-6611f71518ce">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_04edb7a3-211b-48b1-9752-6f8574ed56c9">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_40607fa3-1781-4a67-9448-70afe815a39e">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8f1c5479-f4d9-4fbd-97e0-5d33dad418bb">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_fb939d8a-8401-4c64-9ccf-e066292774ca">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0226d232-c97b-47a4-b15d-b4541408d4e0">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="15">
                                    <para xml:id="para_cfbada7e-e355-4e0a-89ec-22cdc00f534c">Participant Object: ParticipantObjectIdentification</para>
                                    <para xml:id="para_9c64cff5-6225-4f91-aa38-5db73fc40cc2">SOP Class queried and the query (1)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_774d2eaf-c23d-49bb-8378-21147015b781">ParticipantObjectTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_7dca6abd-c2c8-4c6d-8bb2-de1f8ba12533">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_07c56ffc-93d5-4383-bfd3-b48000fe9b58">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>2</term>
                                                <listitem>
                                                    <para xml:id="para_cdfd5aca-3f97-4e18-aae7-49aa0ef95a4e">System Object</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3ff4d912-014c-4624-9160-ad173da07805">ParticipantObjectTypeCodeRole</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_aa71cd6d-fc4d-4fec-9b0c-0b28e3ed8e4b">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d04e041a-23e8-4776-8904-c83440d7edae">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>3</term>
                                                <listitem>
                                                    <para xml:id="para_e14ee8df-575e-4b10-b3f7-74e4a95a4bab">Report</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_46803e3f-c6ca-4bf3-b2ee-166a563d27f8">ParticipantObjectDataLifeCycle</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_0f92e3ec-5100-40cd-9be9-3c7193adbc2c">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f6c18276-9b9c-4e66-9eaa-2adf4c0f8783">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_25e74d13-366d-4542-99ed-1ef72fade930">ParticipantObjectIDTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_14eac641-b549-4fa5-b76e-66c6c3586cbb">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4583bbf9-f48a-421f-8a04-52edd14566a1">DT <olink targetdoc="PS3.16" targetptr="DCM_110181">(110181, DCM, "SOP Class UID")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_88917756-7a92-4514-81c0-8ec3b3e0cd74">ParticipantObjectSensitivity</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_91f8b887-b9a5-4a9e-ae87-98ed1a8e5de2">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6354b42b-7978-49ed-838f-0137ee97489c">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1e2faed6-0b9a-4158-b531-3b8185ef928b">ParticipantObjectID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8eb4b665-5b96-4700-819e-ec1b8b5151f4">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7df1d044-a75c-4a2d-b7fc-15170443b3b9">If the ParticipantObjectIDTypeCode is <olink targetdoc="PS3.16" targetptr="DCM_110181">(110181, DCM, "SOP Class UID")</olink>, then this field shall hold the UID of the SOP Class being queried.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3126bb2f-2fd2-41cc-b910-dcf150f65e54">ParticipantObjectQuery</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_17659d79-1c30-4d22-8dd6-d4193d9ed2b1">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_89c0a88f-db41-4f5a-94cb-3e75859c5b40">If the ParticipantObjectIDTypeCode is <olink targetdoc="PS3.16" targetptr="DCM_110181">(110181, DCM, "SOP Class UID")</olink>, then this field shall hold the Data Set of the DICOM query, xs:base64Binary encoded. Otherwise, it shall be the query in the format of the protocol used.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cc11a949-cec6-42d2-ae77-84ba384d1a61">ParticipantObjectDetail</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c073d38d-53cc-4247-9153-e17f3746526b">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e8c1c378-bb1a-4703-91a8-9d579fde793c">Required if the ParticipantObjectIDTypeCode is <olink targetdoc="PS3.16" targetptr="DCM_110181">(110181, DCM, "SOP Class UID")</olink>
                                    </para>
                                    <para xml:id="para_49f2b246-07ba-4afa-b87f-4ee3cae14eaf">A ParticipantObjectDetail element with the XML attribute "TransferSyntax" shall be present. The value of the Transfer Syntax attribute shall be the UID of the transfer syntax of the query. The element contents shall be xs:base64Binary encoding. The Transfer Syntax shall be a DICOM Transfer Syntax.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_97143e56-b498-470f-8018-21cc22a5f8ba">ParticipantObjectDescription</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c57b7e13-c44d-4867-9d54-6e8434ecde19">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f6803568-ba40-4073-9d22-a326883c0d3c">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d8acaa1a-f33f-4d51-8ac7-f708c09f41f7">SOPClass</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_cacb5925-d4af-48e0-b5b2-4919e3e3b8c4">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_efe7de17-ce62-4964-a89d-d66957d3247f">See <xref linkend="sect_A.5.2" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_43187569-a662-47ef-b740-a6f1b2d7dd96">Accession</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b660e169-73c4-4f85-9a92-98b7fae3e857">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d439419e-96e7-4661-844f-74b0d5cf82e1">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6b2a93da-add5-4325-b82b-aeb3f2f0bfde">NumberOfInstances</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_cfc4f5db-dbdc-49c5-a991-7823ea9107ce">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_62d74eab-00d7-431f-8f66-0db2f456f59d">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8e48bb33-0047-4134-9796-f9a1e8ee3f3c">Instance</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c749785b-7681-49de-9fc6-512f4d4fac71">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0398d1d1-3691-4ae5-889b-dee612966427">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_924c5029-1555-4cd7-b54a-481345506bed">Encrypted</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_fa8ec4dd-c3f4-44a1-aa41-0625b30c7019">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_42fdf573-2c23-4b60-95cb-47e97bf4883d">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_24a90929-8b73-4c93-8dcd-30d97b25ad5b">Anonymized</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_735cea29-9f80-48f8-ae0d-7c80b7936e6e">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0a03b1c3-edbc-4312-8a93-e729bb962aff">Not specialized.</para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                </section>
                <section label="A.5.3.11" status="4" xml:id="sect_A.5.3.11">
                    <title>Security Alert</title>
                    <para xml:id="para_1adf3586-f3c6-4092-b886-42362dbc6020">This message describes any event for which a node needs to report a security alert, e.g., a node authentication failure when establishing a secure communications channel.</para>
                    <note>
                        <para xml:id="para_dd9ffbaf-6ba7-4e83-a941-58e0090d01ba">The Node Authentication event can be used to report both successes and failures. If reporting of success is done, this could generate a very large number of audit messages, since every authenticated DICOM association, HL7 transaction, and HTML connection should result in a successful node authentication. It is expected that in most situations only the failures will be reported.</para>
                    </note>
                    <table frame="box" label="A.5.3.11-1" rules="all" xml:id="table_A.5.3.11-1">
                        <caption>Audit Message for Security Alert</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_5c3806f7-0fca-453a-a390-b4e63e1e0be8">Real-World Entities</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8a1f829e-4f83-40ca-83a1-a3fac28e6e9d">Field Name</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_10712bea-a10b-4bbb-b613-635c574398ca">Opt.</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_6e7dd69a-be3e-46f6-881d-8eaabb0bb4cc">Value Constraints</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="5">
                                    <para xml:id="para_6df215b9-1ed3-45d5-9d90-542d40a871ac">Event: EventIdentification</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d03f2b56-c5e1-4725-8951-54a6a155234d">EventID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_d349f2f5-5010-48df-8cb1-7bd13a9e6071">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f3b49b08-bf93-4716-880c-57a3c9819e4c">EV <olink targetdoc="PS3.16" targetptr="DCM_110113">(110113, DCM, "Security Alert")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b3adaa71-8751-40f5-ba4d-58c7b4512c00">EventActionCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_da2f2d6e-68f2-4a77-a64e-af4037ecaabe">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4c651555-9dac-422c-a43b-ed04c10403d4">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>E</term>
                                                <listitem>
                                                    <para xml:id="para_0ebc172a-3c00-4659-a6d4-6d741906df7a">Execute</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cedde447-a6b2-4360-934a-fd3bfdcc7572">EventDateTime</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_54677b11-888a-427f-8186-c6228771665b">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f5261911-4a97-4a4d-974a-3da90ac81680">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1485dc36-2675-4c11-910d-c160a558b1e5">EventOutcomeIndicator</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_1d6c10b6-5816-4292-b7fd-5632d25a6475">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8bef85db-5ee2-4e6c-9b0f-f2d566efbc69">Success implies an informative alert. The other failure values imply warning codes that indicate the severity of the alert. A Minor or Serious failure indicates that mitigation efforts were effective in maintaining system security. A Major failure indicates that mitigation efforts may not have been effective, and that the security system may have been compromised.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_437d0bde-33df-4e74-a526-c0898cddbd72">EventTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_cab28617-ca1f-4f59-bb09-9aebf4554469">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_564dd3c0-4919-47e6-bfd8-deb08dd23f3b">D<olink targetdoc="PS3.16" targetptr="sect_CID_403" xrefstyle="select: labelnumber quotedtitle"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="7">
                                    <para xml:id="para_02a62c6f-5bd7-4798-975d-b30a3f5af7ff">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_79c82c46-1b7e-4ae5-91e1-ed1c6ed0259f">Reporting person and/or process (1..2)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_480753da-ee67-43c7-9b30-43a544cf219e">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_00e402a6-2b98-4523-b4d8-50d7d5abedab">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9b5ed068-0ee7-4a94-a805-8ecb23d904b5">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_06bc8734-33de-463a-ad6a-2a74bc72e79d">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ad434baa-3dc1-4dff-945c-cd349f30b254">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fadcb26e-f4cb-4b0e-b153-611668a58305">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0bbd1923-47cd-4aba-9224-8c5c88735940">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e72acfa4-af02-471c-8731-6b20ba30c79a">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_86b903fa-ffbc-4276-8c9e-7944aae80b1b">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_24ae20df-5814-4ff6-a1f2-1c747efff068">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_df5d9cef-b3b6-432b-b10d-df8a962335ea">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8c049bb1-2f22-42f3-88a4-8486b7ed5f2f">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_64d5d4b5-a7a5-489c-8261-bb4eb31b9820">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_5d17bf01-d373-4b81-a053-6f95f0d22eed">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1dced9ad-3335-410c-909d-1a132e1c1e30">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e31dd4f4-d018-4c2c-a14b-fd72285a9135">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_d9709dd7-8e7d-40ba-a3ca-3238e97c47c3">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_39fd33a8-ca48-4485-9cdb-16c05bd38209">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ec25700b-bdca-462a-aa07-7df287868174">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_038a5692-e847-454b-8a70-199582854639">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9241dba0-27be-4e17-bf32-dffb14448dd4">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="7">
                                    <para xml:id="para_e4fa9fa8-9e52-4e4e-859a-9f8d2899c6e3">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_9217b778-ed61-4ce2-af0a-131d81ef1b90">Performing persons and/or processes (0..N)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9b054cd0-5ede-4c39-b024-22368c89283e">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_fa53f220-7c43-4a12-a3fd-e0af49eab730">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_99d8b8af-e689-4d5c-bd69-9d265ee848d6">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8f14b1dc-2578-4e65-9295-016ae9cbdf06">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_0eed1e01-0883-4c8f-892c-161cd8fc069d">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_bbf99814-ad05-4dbf-8380-bfdeab4e5675">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d0f24f21-dd60-4c5b-9a0a-78701f73e0a6">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_0a7f7f3a-94a4-4da7-92eb-8163541c0b46">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f26cf2fb-c1d3-4756-aae2-3821e8159396">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a83f807f-fff4-4dd4-aa1c-8d6a63a3be6f">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_96355f90-ca62-490d-9cf4-023d491e3391">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a7a202cf-f537-4688-b45c-7227aaff11ef">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>false</term>
                                                <listitem>
                                                    <para xml:id="para_9ad756a1-ba8d-49e4-8410-5290f16b9036"/>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_213d23d3-5479-47f1-9e61-11e6bd62376c">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_28ddcff7-ba4d-4e8d-b6fd-344370873888">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_20ac22f4-8141-4ba2-95e4-0655284b65da">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e62a0835-74f4-4ebd-b199-5ebf4de2c4f2">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9247a13e-0e75-430b-a6ff-80ded0b84dc5">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_43308ecd-a5bd-44ad-958f-ad2c4883030f">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_daccee99-f7da-4aa8-828f-2fca443b1944">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4cf11567-eec0-4955-b1e6-dce98946a1a8">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_44947973-7c1f-4f95-896b-79c5c7c9ec70">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="15">
                                    <para xml:id="para_21e90c5f-4f34-45cd-91bd-4612083dcda4">Participant Object: ParticipantObjectIdentification</para>
                                    <para xml:id="para_d76f728d-62d6-4e1e-92a2-c5d06f5e37c6">Alert subject (0..N)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e2a64c55-b18a-4beb-a6c0-c85d04a708e6">ParticipantObjectTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_96922e88-c73b-435b-84ea-40e38262bab3">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_85d9756d-e46a-4dee-87bd-e2be3a5078e8">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>2</term>
                                                <listitem>
                                                    <para xml:id="para_3687b2fe-ee12-4383-acac-f3d8def11c80">System Object</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0f281def-e747-416e-ac6f-5af319cc03eb">ParticipantObjectTypeCodeRole</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_07287e02-b181-4f5c-848b-1095d079dcc2">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6815e1e2-eed0-4768-8349-30e6ddac94f1">
                                        <variablelist spacing="compact">
                                            <title>Defined Terms:</title>
                                            <varlistentry>
                                                <term>5</term>
                                                <listitem>
                                                    <para xml:id="para_3d157ead-d16a-4c38-8ec1-bfd9f9afd088">Master File</para>
                                                </listitem>
                                            </varlistentry>
                                            <varlistentry>
                                                <term>13</term>
                                                <listitem>
                                                    <para xml:id="para_70b32982-e70b-48ea-bf85-942f829d557b">Security Resource</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_82ccf897-4637-45c4-8dc9-f7e020325ccb">ParticipantObjectDataLifeCycle</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_166a2f59-bcd3-4262-9018-57090e42b757">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_952b7292-c71a-4ac4-9906-da64e5422620">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0ae4f986-d763-4a20-8bc1-2f75efff79ba">ParticipantObjectIDTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_37b0765e-5409-4138-8a6c-2ba742cef334">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9fbce05e-40d4-40d2-bd03-58946d153ecc">
                                        <variablelist spacing="compact">
                                            <title>Defined Terms:</title>
                                            <varlistentry>
                                                <term>12</term>
                                                <listitem>
                                                    <para xml:id="para_124d0112-bdb2-4dd5-9bb7-de43ef237517">URI</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                    <para xml:id="para_4636a976-08a2-42ec-b18e-b9fd254cd11a">DT <olink targetdoc="PS3.16" targetptr="DCM_110182">(110182, DCM, "Node ID")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2e92ad3e-4be7-4be0-aa15-0058c514beea">ParticipantObjectSensitivity</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_fc903f0a-4b6a-4216-9e0f-28376a78a063">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a060d41d-411b-4687-a7a6-95305e0f9940">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fd820dc9-98d6-471f-81f3-2db91b3ea324">ParticipantObjectID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_cc08335e-55e3-475c-a7a6-53a9df9b969c">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2263783b-689b-4fe7-84fa-1bc74dc0ed1b">For a ParticipantObjectIDTypeCode of 12 = URI, then this value shall be the URI of the file or other resource that is the subject of the alert.</para>
                                    <para xml:id="para_6c7b430c-9eed-4b42-ba0b-d8de5a5bd5b6">For a ParticipantObjectIDTypeCode of <olink targetdoc="PS3.16" targetptr="DCM_110182">(110182, DCM, "Node ID")</olink> then the value shall include the identity of the node that is the subject of the alert either in the form of node_name@domain_name or as an IP address.</para>
                                    <para xml:id="para_7cca6ab2-10d0-4e94-a29e-3a7a0287686e">Otherwise, the value shall be an identifier of the type specified by ParticipantObjectIDTypeCode of the subject of the alert.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a80cb853-81f0-408d-8b74-963ab95cb767">ParticipantObjectName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_716a3357-3e40-406a-a20b-b8af7c4812b6">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_701f16e1-f593-464c-8292-3e255215b43c">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_09f61408-3545-46bd-84ba-c525c6cd7a00">ParticipantObjectDetail</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_17c7c00f-ff84-4d99-92f5-a834b8aa7f63">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f770bb9e-68e5-4a4e-b6d1-e179a872132c">An element with the Attribute "type" equal to "Alert Description" shall be present with a free text description of the nature of the alert as the value.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2ac953b6-3e72-43ab-8416-1708f4e4f5d5">ParticipantObjectDescription</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_1a4172b3-b0a2-415f-9c0b-950d1166dccc">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1696b828-cc8b-41ac-be16-8fd55180113c">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2edf5252-19b5-49e7-978d-c45d3cba0bef">SOPClass</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_6a74bdf2-cbd8-4a22-9652-856de18e40f6">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_741c67df-adb6-4ecd-9d5a-ea7a3ffb1812">See <xref linkend="sect_A.5.2" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9404ee79-e4a1-42ad-856b-4655f54f2e9e">Accession</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_d9f5d210-8629-4341-b2c3-b9701d872237">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2509bdfc-e15c-4584-bff2-944f6c8e62ee">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9f4eb48a-7778-48b5-852f-a4669f6ceb52">NumberOfInstances</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_7df09927-da77-408a-828f-dd621520c366">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_253b4c34-b079-40cb-abb9-3a1234c40429">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_bd1c49bb-7cf5-4b3d-a035-63297d175e95">Instances</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f8e7f70b-4b9a-44cf-8dc6-ef74bb7ef8f1">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_65da5165-338a-4d03-9f66-1164822dd355">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5cd61fd6-5d97-4909-a4fe-eb776c108a35">Encrypted</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_03b82aee-9b29-4d9d-9257-2a6ac76e9d34">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_bbd335ad-b6c1-495c-8fbc-92f948013715">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b9e31172-f97b-4e0a-80e5-8b01b3eaba41">Anonymized</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a4a44e4d-058b-4c68-a394-9dbd047de28d">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_28ba06c8-8201-4703-8ee4-c1c6e298d3f5">Not specialized.</para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                </section>
                <section label="A.5.3.12" status="4" xml:id="sect_A.5.3.12">
                    <title>User Authentication</title>
                    <para xml:id="para_e69352a1-1f55-490c-b3d4-1495debedef5">This message describes the event that a user has attempted to log on or log off. This report can be made regardless of whether the attempt was successful or not. No Participant Objects are needed for this message.</para>
                    <note>
                        <para xml:id="para_5dc0df94-8afb-47e6-937c-79d1b073baab">The user usually has UserIsRequestor set to true, but in the case of a logout timer, the node might be the UserIsRequestor.</para>
                    </note>
                    <table frame="box" label="A.5.3.12-1" rules="all" xml:id="table_A.5.3.12-1">
                        <caption>Audit Message for User Authentication</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_dc6e644d-11a2-4939-bba7-fcc154a2ea52">Real-World Entities</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f145b6a9-464e-4123-a9b8-659192fe4d08">Field Name</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8a7f9ad5-04ae-49e4-97e7-28c71c4fab48">Opt.</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_58398200-70bd-46fc-b029-29d951813265">Value Constraints</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="5">
                                    <para xml:id="para_d5252e8e-b74c-4ee2-b9e5-2f299f8a5b71">Event: EventIdentification</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2bba08ff-1c30-4da3-9602-3928a7f46da3">EventID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ae242932-1587-4fbc-be92-22d2c9bbc2e3">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_61ca1586-1094-441f-ba91-1cf004a0ff3e">EV <olink targetdoc="PS3.16" targetptr="DCM_110114">(110114, DCM, "User Authentication")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f7fb76a2-a293-40f8-adaa-18c3165eaa3c">EventActionCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9418e67f-b28a-4612-9325-b98e7efb23c0">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_43c9a53f-3fdb-46cb-af3a-74ea889e723b">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>E</term>
                                                <listitem>
                                                    <para xml:id="para_f32c9174-d9a8-49d1-9ead-fdd3842be0e6">Execute</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d7750740-a7b1-4415-bfe6-7cc89fb85e05">EventDateTime</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_bab61a95-0b56-4eba-9a04-102bbe8b89bb">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d60772df-6eb7-4b56-b9ab-d52283ce6a7a">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_91bd4936-7c15-45ab-8ba2-9daeb201de45">EventOutcomeIndicator</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_d62b238c-e265-4a6a-b8b4-9316415c1e18">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8cf6e7d0-a472-4f2a-bc59-a2c24b25c703">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f4411186-81a2-49ed-b7df-a642847a515b">EventTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c362610b-ee49-4189-ae28-bb5690b91464">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2e76cdb0-8409-4fd2-bb1d-b792c8ff3305">DT <olink targetdoc="PS3.16" targetptr="DCM_110122">(110122, DCM, "Login")</olink>
                                    </para>
                                    <para xml:id="para_dc8eac5f-70c9-4b27-8843-1151d4483643">DT <olink targetdoc="PS3.16" targetptr="DCM_110123">(110123, DCM, "Logout")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="7">
                                    <para xml:id="para_ebc3b7d6-ac9b-4f69-bee2-8fe488566403">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_1cb392a4-4976-423c-8dd2-70ed3e50d451">Person authenticated or claimed (1)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fe0a20c8-1681-49c4-91e2-4e45fa352a3d">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_607b0c42-9c38-4030-a86c-e36ffe994be9">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_82649ced-a38f-4db4-956b-4c85ca763321">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f9262a09-f173-4ebb-9978-cfdd2fb9c29b">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_1301373b-83c6-407f-940c-836a87d72a29">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_92af7140-c697-4899-b4f4-59824137409b">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1bf319e0-8c77-4578-a311-3268317beb51">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_0885085a-d691-4d01-ac6c-c866b0bb3f94">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a36ee798-fcba-4346-8ac1-549ea6a113ad">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b1196bc0-1b78-4dca-9f8e-ae1309f10b37">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b4e11852-377e-4de1-a909-42cd376e69d3">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_15f6a2ff-0d64-4f1f-93c0-659b341c1a25">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_28389934-3bf4-4e13-921b-1a55b6b2b5fd">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_3f331707-07f9-41fa-a602-030c8913f7ab">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_33238b8c-3ad4-4f8e-b66b-44e838417fc7">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0efded65-713a-4aa7-828a-cf69b688b9dd">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_11e9fb4a-b56e-40fc-b173-25cbdf03acb7">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ce2bbe3c-85f1-4ce7-9fcf-bd10179afd03">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a37aa13d-0ce3-41b8-abd4-6f37bd896bfc">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f7a0ae0d-a37a-4885-9ccd-00afe5e12c83">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_212a0a90-32f7-480d-b842-9aec51d47a84">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="7">
                                    <para xml:id="para_0751ffdf-bb8c-44ca-bbdd-b0a335fd0dca">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_01d621f6-693a-4b51-a600-d8a588b206c1">Node or system performing authentication (0..1)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_39ce1425-640a-4690-b754-51c782969f4e">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_1820d6b6-f6de-41b9-901e-d517763987b8">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_27a72de2-f123-4084-8a3d-121593aadbc3">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d098aa66-f82f-4fe1-941a-bc58f7b19ba8">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ffe10ece-78ec-4833-832a-800164942ee6">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_33115749-14ab-48e6-a9bf-30b682919e30">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_dfe7eaf4-8904-4c47-b284-957958969985">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9d0f0380-2f1c-40fd-b710-f38c4e1bd207">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7d4a8648-2cac-4b95-877c-2e5e707b73f0">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_101abc00-f571-4454-b710-5b7403197867">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b88e110d-8d4d-4ac5-a8f2-35447de15f33">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5ca8e0c2-0e1a-4466-a404-91fdfa7a748b">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6440207e-f888-4090-8370-ade90cf38474">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ede1d19a-9a12-4185-95d3-9715861d3f6c">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_092648a4-df62-40b5-8443-a0c86d642fa2">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2c0ede81-3c0b-4827-a67c-27a02484af60">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c7c93fc2-0fff-4083-be55-0a45c17afddc">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a5136248-f836-4ef9-b5f9-97b8e4ff73d0">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3318f4a1-d2e5-4c05-81f9-bdb86fdc0d3e">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e24e5c91-cb8c-4f13-ad39-9ddf0b0da07c">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_218267e6-f97d-49c1-9b52-68b2f5183850">Not specialized.</para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                </section>
                <section label="A.5.3.13" status="4" xml:id="sect_A.5.3.13">
                    <title>Order Record</title>
                    <para xml:id="para_ab8508ac-f840-45d5-8144-ad6861a87374">This message describes the event of an order being created, modified, accessed, or deleted. This message may only include information about a single patient.</para>
                    <note>
                        <para xml:id="para_f05725a1-0df1-4fd0-bdd7-bdb4b0f93ea4">An order record typically is managed by a non-DICOM system. However, DICOM applications often manipulate order records, and thus may be obligated by site security policies to record such events in the audit logs.</para>
                    </note>
                    <table frame="box" label="A.5.3.13-1" rules="all" xml:id="table_A.5.3.13-1">
                        <caption>Audit Message for Order Record</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2afc5d8e-252b-48a3-8bc1-e657edcafcf5">Real-World Entities</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9d4882d2-850c-4842-969f-2d1e4d7fc10a">Field Name</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c38ff30a-22c1-4710-9f64-5f5285b09d58">Opt.</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8ce55e50-b32b-4da9-b412-44a58772650c">Value Constraints</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="5">
                                    <para xml:id="para_805196d5-669c-4b90-a52f-f725742604c2">Event: EventIdentification</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_527687dd-b633-45bf-b0f5-23e8f6a3b0ad">EventID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b9ae33d6-6a81-4b33-afa6-9db45dce6ca0">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c97ed375-e4e4-405a-a542-e28d1cefed90">EV <olink targetdoc="PS3.16" targetptr="DCM_110109">(110109, DCM, "Order Record")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_608f0939-4aba-4d16-ab20-1b8a7fac2cb6">EventActionCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e2cb073a-38bf-492e-ae0d-22f2df4aa5c3">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a27fe25c-c84e-4d57-8773-95242835da6b">
                                        <variablelist spacing="compact">
                                            <title>Enumerated Values:</title>
                                            <varlistentry>
                                                <term>C</term>
                                                <listitem>
                                                    <para xml:id="para_a3684c26-c912-4b56-b816-8b1a4137dff2">Create</para>
                                                </listitem>
                                            </varlistentry>
                                            <varlistentry>
                                                <term>R</term>
                                                <listitem>
                                                    <para xml:id="para_c8efeb4c-a747-47f1-96ce-1f2db5f2ad02">Read</para>
                                                </listitem>
                                            </varlistentry>
                                            <varlistentry>
                                                <term>U</term>
                                                <listitem>
                                                    <para xml:id="para_948397c9-6cbb-4281-86b0-fd1f70d5a642">Update</para>
                                                </listitem>
                                            </varlistentry>
                                            <varlistentry>
                                                <term>D</term>
                                                <listitem>
                                                    <para xml:id="para_f8c197e2-a38e-4fd2-9a57-fa917ecc4f66">Delete</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_29924018-b4df-4210-b6ef-e0734439d5bb">EventDateTime</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_28397e8d-4d12-4c3f-bd30-29bc43f60979">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f2a2728a-2dc1-4f8e-a40d-126db609824b">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0b439953-587a-4fbe-8b6a-7ec2c5685a9f">EventOutcomeIndicator</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_05902fed-ff8a-4ec1-b585-5e032ee48d65">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_283aa3c0-f81a-426a-94d2-317b40692f60">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d69978b6-cf97-4614-9aa1-de5e04c5afe0">EventTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c02a2233-058c-4d79-9f24-5a61452ab9ae">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5706c56a-90df-4015-a8bc-d7b70303ee59">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="7">
                                    <para xml:id="para_8a8a6a38-a295-49a4-b77c-d898022ad744">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_8a225815-b712-43e3-ace7-e4f5cb81fa98">Person and/or process accessing or manipulating the data (1..2)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7523dc28-14bc-4105-b07e-2fff70043ce5">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_6253984b-b1cb-4860-af4e-f91ea267d583">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_63995238-4dfb-43cc-850b-0c60bd0cbce3">The identity of the person or process accessing or manipulating the data. If both the person and the process are known, both shall be included.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fe08bdf7-2a95-4dff-9c8a-b2e74859fb20">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_1c719b12-dfdf-43fb-afa9-42a41b36bae6">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2ce3687e-98a7-4852-ab9c-01550eaec225">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_671a8256-7c7b-4345-85c9-71e7c5cc6f54">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2eebd716-eea0-4b20-9fe6-17403f75b6bc">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a54fcd21-8afc-4807-948d-1e037c60b625">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_484078ec-424f-42df-aaa8-51eb0f6d7393">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4171f81a-63a7-4f3a-bcc5-8c07f8be22ae">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_57e28cb3-dfa9-49dd-b98d-8f6abc67d7a0">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ffeb4da5-fd8b-43ba-b3a7-f9dcd5b39b3a">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_d180d9dd-4470-49c5-bced-7804c56cd517">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_01e56bf4-2935-45cf-a5a6-a6b5aad7e5da">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b2f73d1b-ba17-4b0a-8646-b5e6c0d5bcf8">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_69ec3a7d-c747-416e-aa41-08679ac4e8cb">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d8b60ce1-23fe-439f-8051-3c4dcc6bcd10">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c656cd75-256d-4517-aa5c-f8ac8a7d8fc8">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9fc915ad-ec28-4e66-8c66-882f6d1c1f50">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_27ac5788-ba7d-4156-a990-dd1fbb16adf3">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="9">
                                    <para xml:id="para_aeec97c2-18b7-4cc4-aae3-37724ac94c70">Participant Object: ParticipantObjectIdentification</para>
                                    <para xml:id="para_44021b28-f678-438e-9e4d-caf99db07f0e">Patient (1)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b8a10f7a-ea81-4e24-902f-d45d8ec079ea">ParticipantObjectTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e38defd5-9ad0-4e6c-bf8a-722f27239eb6">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3b12925f-56d8-428a-b0f4-254244d58922">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>1</term>
                                                <listitem>
                                                    <para xml:id="para_606e666c-e6d6-4e01-84af-654e52e4b62b">Person</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_97170c45-bf77-42da-bede-7d05b6018cd6">ParticipantObjectTypeCodeRole</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e5eead41-c913-4f19-92a6-eb94f1c90652">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2f50b36e-390f-4f02-b8c6-1ca953480d2a">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>1</term>
                                                <listitem>
                                                    <para xml:id="para_39d04407-4eb5-4169-8ea6-afade2e3ec04">Patient</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1011cd5a-0d2e-42b1-a7d3-70bf11ddafca">ParticipantObjectDataLifeCycle</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4ff899e6-a94f-461f-8f8b-8fd483a1c975">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_76326c57-e357-4a80-a78e-71a3b4a5eaaa">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_335c83c2-e0e3-4850-bf3b-063524ec5090">ParticipantObjectIDTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c95e4489-7b43-45be-b515-635789f0eefc">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e97a3ab3-4823-4751-8440-903567fadd35">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>2</term>
                                                <listitem>
                                                    <para xml:id="para_1e5baccf-31a0-4f1d-bd98-4a215cd9aaff">Patient Number</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b127a4b3-0fc6-4f15-8d9e-ddea3791f532">ParticipantObjectSensitivity</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_6e17c34b-a4d6-49e9-899c-d1e108cbc7f8">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b4f13b65-dd9f-4274-9fff-82e05b8877cb">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a84487be-092e-4d57-adc5-3ba66c3fd522">ParticipantObjectID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_5ab20ed5-d1cb-4e3e-8e7d-8a3e2461742b">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_513d005f-523f-4e7c-9004-319cd0346a3b">The patient ID.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b793d365-2437-49c1-9cdd-b6329a82b017">ParticipantObjectName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_72be4824-29c7-452d-918c-6343b21a793c">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8f38b47e-dcfb-4b15-996d-4052726c0f93">The patient name.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cacee479-cfd7-4069-85f0-283b6a0e6006">ParticipantObjectDetail</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_96ef3e3d-b6f4-4882-9e9b-9295b0d4655a">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_745a116d-069e-41c9-b286-3dda1b69a238">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e37541b4-ad3f-4ab5-954b-e9dfe394b44a">ParticipantObjectDescription</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4741d2bf-1351-4206-b15c-0fd7e45b91a5">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_babdd855-1ab6-4ce5-96fa-5b2432360bff">Not further specialized.</para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                </section>
                <section label="A.5.3.14" status="4" xml:id="sect_A.5.3.14">
                    <title>Patient Record</title>
                    <para xml:id="para_e4fd889b-eddb-4d1d-b042-b9df0f8dfda0">This message describes the event of a patient record being created, modified, accessed, or deleted.</para>
                    <note>
                        <para xml:id="para_f3db3501-47d6-4acb-9a59-bbae83a58a1c">There are several types of patient records managed by both DICOM and non-DICOM system. DICOM applications often manipulate patient records managed by a variety of systems, and thus may be obligated by site security policies to record such events in the audit logs. This audit event can be used to record the access or manipulation of patient records where specific DICOM SOP Instances are not involved.</para>
                    </note>
                    <table frame="box" label="A.5.3.14-1" rules="all" xml:id="table_A.5.3.14-1">
                        <caption>Audit Message for Patient Record</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_3d6919cb-96d8-4e76-85b0-7f8ce5419071">Real-World Entities</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_0ab06a3a-ae50-4019-8ae2-05d46596407f">Field Name</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_aa9c1948-70c0-497b-a797-a495a6dc7f4b">Opt.</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_21b33547-4cea-4bdd-8b0f-25ab77aa0a5a">Value Constraints</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="5">
                                    <para xml:id="para_28a25721-9adc-48b7-be8f-cb3f70b91010">Event: EventIdentification</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_014cbc9a-4ac5-4353-a49e-d9f43892cdee">EventID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_3d3ecb73-4155-4369-835d-73460ac3acb3">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c282e75e-97ff-4ded-94ed-2407bc804adc">EV <olink targetdoc="PS3.16" targetptr="DCM_110110">(110110, DCM, "Patient Record")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ac80af85-a4a6-48aa-9daf-4422f67f38d4">EventActionCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_63810f29-deea-4331-b678-e08bf9ab1e2c">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_59fdeea9-44b8-45d5-8078-fc1443f2677a">
                                        <variablelist spacing="compact">
                                            <title>Enumerated Value:</title>
                                            <varlistentry>
                                                <term>C</term>
                                                <listitem>
                                                    <para xml:id="para_5da65fca-0ca4-4485-97d4-1233ebb30894">Create</para>
                                                </listitem>
                                            </varlistentry>
                                            <varlistentry>
                                                <term>R</term>
                                                <listitem>
                                                    <para xml:id="para_b5db4b9f-8e30-4da8-a34f-9651e9491549">Read</para>
                                                </listitem>
                                            </varlistentry>
                                            <varlistentry>
                                                <term>U</term>
                                                <listitem>
                                                    <para xml:id="para_2cdbd00b-16e6-4732-ae2a-927193d51af7">Update</para>
                                                </listitem>
                                            </varlistentry>
                                            <varlistentry>
                                                <term>D</term>
                                                <listitem>
                                                    <para xml:id="para_d58d1955-0ba3-4ff9-b80c-8eb07a0b884a">Delete</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_07c13497-4443-42c1-8cbc-a653fca4c470">EventDateTime</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b92ae0e2-07ab-445d-9b00-8779204e0a0c">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8b15bcd2-aa22-44be-aa88-90468643dee8">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a803ac94-1384-4540-8f64-1b7cdc467159">EventOutcomeIndicator</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_0fcd3be4-a15b-405b-957a-3596deedc560">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fece57fd-2fa8-4acb-8112-e3b8f0bbb484">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f3ed4e26-8656-4c7b-b9cb-bb3bb774559e">EventTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_1487da71-c6eb-4975-9eb2-2f2d7cd8780f">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_70bcc819-ef30-4cf6-9d3b-92c606ec3313">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="7">
                                    <para xml:id="para_42c712cf-9314-4898-929a-82af932d2708">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_d9e37828-5403-42e8-911a-b5c3f92b3e0a">Person and/or process accessing or manipulating the data (1..2)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3fbeae0f-ca0c-4050-9bf1-f47e9e704b60">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a46d88c5-4d3e-4028-b364-813111cb3ed5">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_aed8cc38-145d-480c-ab3b-8180f0faff0c">The identity of the person or process accessing or manipulating the data. If both are known, then two active participants shall be included (both the person and the process).</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1fbc086c-2f8d-4eed-99b5-20e2cf5542dc">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4a9478a2-713e-4829-a853-adde75992cde">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_52c260d5-028a-44dd-ba41-a95376b5910a">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1248aef2-193e-4fcb-82d4-e1cbcb6dedf8">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_32d160f9-feed-4520-9c8c-b231cdd579ca">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0ab21b8c-90f7-44dc-b5d9-81a958e68086">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8f22dad8-4352-4254-a706-440a275dd1eb">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ad27a823-2e7a-429a-aaf8-6a0802f3a5e7">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e2b8df58-df29-4a5c-a9b0-1b43ef5939d2">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6ff7b7be-b39f-4443-a717-1d2983cc5fa2">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2e301ebd-be55-4eea-94cc-6c24276db7bf">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_815b0a21-f948-40d3-836d-c6f8536faa9e">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_676005b4-36d4-4629-acb7-bcb7b5f73e6f">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9a66b866-e550-4233-a157-f06c5ca86991">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_51f7ca49-fa6e-4f77-b624-138ecc02730c">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c981a68a-568e-46f5-b151-33f83ca200c6">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_7aa851c7-fd87-4642-9f6b-15d5cd52b7d1">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3e93c885-e0d3-425e-9bc6-eafd7dba59af">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="9">
                                    <para xml:id="para_eba15fd0-ce2a-4915-9c27-6f1678a27f6c">Participant Object: ParticipantObjectIdentification</para>
                                    <para xml:id="para_1a135e42-2522-4080-b1b4-8dccd3bc44db">Patient (1)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c3385882-3557-461a-95b9-b6db5a362e0f">ParticipantObjectTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_404173ef-ae80-4f9a-a8c7-4ccd321047d5">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4b10c06e-8b73-400a-885e-cf3b284ffde6">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>1</term>
                                                <listitem>
                                                    <para xml:id="para_e174283b-34e3-46f1-aac1-4967b94267a2">Person</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e91f52d8-f9ac-4eaf-a550-3269445553d5">ParticipantObjectTypeCodeRole</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_22a98ff6-f558-4322-9a09-3132946b1723">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_bf49b055-8890-4077-8031-44c72d2674e3">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>1</term>
                                                <listitem>
                                                    <para xml:id="para_f4f30d9d-4c6d-4b83-b2aa-0cf537e6a886">Patient)</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_313e51b4-b256-4adf-9854-4d909ac38605">ParticipantObjectDataLifeCycle</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_bba7f394-baa3-48bb-8a71-c1d2099d84ce">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6311eb9e-afa8-4158-b3a2-ae33cb6830ec">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_db3f8cd6-4b96-4bbf-a019-f446b7ef08bf">ParticipantObjectIDTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b3732485-97c9-41cb-865e-8fdb2009aac1">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_79c63327-a507-468c-bded-5216f10cfa23">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>2</term>
                                                <listitem>
                                                    <para xml:id="para_b7572a3f-8f0a-48aa-babb-dff4e31c754b">Patient Number</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5235c7e5-9b20-47d8-a3ca-2ec3e30e1289">ParticipantObjectSensitivity</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f43ea83b-d204-4780-849f-246338c80d12">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c0fb3d6c-ab61-4e4b-828a-3903a3fc8a63">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_602d90ac-2d09-49b2-b00a-282af684af35">ParticipantObjectID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_3e3ae04d-0533-4b8c-b65f-d2c847721c63">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_eb577b32-1a99-473f-bb8c-cc9c9ed7fd18">The patient ID.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_471f9e15-9ec4-4351-9ee4-1c3cfac7d444">ParticipantObjectName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_cbe99686-144e-4890-a256-e7bc9aa227a7">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3eec0281-4b71-40bb-a2d9-f6ab8a814a86">The patient name.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e628e6d1-b34e-44ba-83dd-79d587c9a163">ParticipantObjectDetail</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_463c5184-96b0-4eed-893f-6318ce4f3a1c">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_05465c6e-8839-40bf-b014-67e110f6dd59">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9f4ae468-9dd6-42ba-b1c1-f15b4b1d9b34">ParticipantObjectDescription</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_427cc134-65ec-44b0-b1dc-f021ba4a758e">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b0454216-449a-4422-84f9-f320fb003ae9">Not further specialized.</para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                </section>
                <section label="A.5.3.15" status="4" xml:id="sect_A.5.3.15">
                    <title>Procedure Record</title>
                    <para xml:id="para_81bc1b81-f300-4b49-b575-f42563acbcce">This message describes the event of a procedure record being created, accessed, modified, accessed, or deleted. This message may only include information about a single patient.</para>
                    <note>
                        <orderedlist>
                            <listitem>
                                <para xml:id="para_04a04ac7-238b-4c6f-a14f-692b40c1c3e5">DICOM applications often manipulate procedure records, e.g. with MPPS update. Modality Worklist query events are described by the Query event message.</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_7e7646dd-bb49-427e-9405-65321de4ffac">The same Accession Number may appear with several order numbers. The Study participant fields or the entire message may be repeated to capture such many to many relationships.</para>
                            </listitem>
                        </orderedlist>
                    </note>
                    <table frame="box" label="A.5.3.15-1" rules="all" xml:id="table_A.5.3.15-1">
                        <caption>Audit Message for Procedure Record</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_952f316a-7ca5-44c1-8040-f82d9c91008a">Real-World Entities</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ce6d54f1-ee49-4b5e-a85b-2687b000c4f4">Field Name</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_78d96e21-4e11-42d1-8f36-90ab92993703">Opt.</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_3306a71a-869c-443a-97a6-751ff1ea4917">Value Constraints</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="5">
                                    <para xml:id="para_0341d3a0-01d6-47a3-9e9e-0e9922a46903">Event: EventIdentification</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4d09c31f-d955-45d2-b201-3874a565f843">EventID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4db38de5-d8b7-4afe-9c69-b07aae3d1668">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_05773c8e-8177-4c96-988a-9056b3f946b5">EV <olink targetdoc="PS3.16" targetptr="DCM_110111">(110111, DCM, "Procedure Record")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9f3603bb-10ce-4521-90ed-aa939c7f9d18">EventActionCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9b4103a3-77a1-4fed-a3ff-2427961edebd">C</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_23ebce19-dd1d-4b94-bd44-8be9497400dc">
                                        <variablelist spacing="compact">
                                            <title>Enumerated Value:</title>
                                            <varlistentry>
                                                <term>C</term>
                                                <listitem>
                                                    <para xml:id="para_a2e51ca5-dac6-41c9-a031-e3fbffef3077">Create</para>
                                                </listitem>
                                            </varlistentry>
                                            <varlistentry>
                                                <term>R</term>
                                                <listitem>
                                                    <para xml:id="para_c619e9fa-331d-482f-b6d5-ccc9c4d5553c">Read</para>
                                                </listitem>
                                            </varlistentry>
                                            <varlistentry>
                                                <term>U</term>
                                                <listitem>
                                                    <para xml:id="para_0ad36f2a-3f12-4f4e-8ee5-9d1fbe8a672c">Update</para>
                                                </listitem>
                                            </varlistentry>
                                            <varlistentry>
                                                <term>D</term>
                                                <listitem>
                                                    <para xml:id="para_0f32b48b-1a60-46b8-ad29-771fdc49f78c">Delete</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_250ffe77-0c6a-45ee-9324-6a862f6349c0">EventDateTime</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_6d4ad506-8bfe-4d1f-8848-27c778ff7f5b">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_09e724e6-723d-4dce-80c1-960b78d393c3">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b1cc85ca-109d-422f-86b7-12a7073491fb">EventOutcomeIndicator</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8c1b6bc8-4932-4e0f-9bcc-faefbba954d9">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_304d1c13-aaeb-400f-b165-c052c541a77b">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_42a8b66a-0216-4261-8ee2-ab27dc737161">EventTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a8f475cd-2c6f-4466-a847-e86c4a1d4a09">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4e641787-1444-426d-9d5b-2890da7729cf">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="7">
                                    <para xml:id="para_efa040fe-8cf4-44b2-a281-f5f327cd58e5">Active Participant: ActiveParticipant</para>
                                    <para xml:id="para_ae5d107c-2b45-4c1e-874d-efd96c87b752">Person and/or process accessing or manipulating the data (1..2)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_41a2cb82-e52b-4488-9bbd-18f49f9331d4">UserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8e03e55b-465d-4bc7-bb00-74238e4b1f2b">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ebd1d2ac-738e-4743-945e-d65d727148dd">The identity of the person or process accessing or manipulating the data. If both are known, then two active participants shall be included (both the person and the process).</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7baefe57-342e-4a2a-a729-2e56cee9602f">AlternativeUserID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_bc8c371f-2ee0-452f-b610-1db5a95842a0">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_08e221df-3ba6-41e3-ae34-19053aca4a4c">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1278cefe-1535-479f-9713-cb64ca6bb408">UserName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_7a1bde4d-f7e5-40a8-9afd-ce2ad19d35bd">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_87d4a4d7-4270-4fc3-9b52-df0c1be41e98">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b7448495-69b7-4a6f-86d0-45b5b0bf81fc">UserIsRequestor</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_6576ccc2-bad0-432c-94b3-0b1a83b873f2">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_dc7fe83e-127c-46a7-84d3-1d6e5408a10a">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6c7d195d-909e-462c-8ee3-8fe989d366aa">RoleIDCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a35f68b3-c9f6-46e8-bc52-a90a5b27cfc8">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5cab8c1a-f0d2-4324-a7f4-220ff742d255">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_031e8d1a-d1d1-4756-84e2-c9cd187f2b94">NetworkAccessPointTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_63293731-8112-4918-9387-6b8fefa023d5">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_86178fce-be52-4fb4-b203-9430c4f26278">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_08b110c0-dda3-4916-b492-015e17aec29d">NetworkAccessPointID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_49372180-6e3c-4eb8-af08-67c8512a8117">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f2fc4daf-e4ef-473d-aa45-10c72211e09c">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="16">
                                    <para xml:id="para_c7f9155f-beb0-4da3-8f12-e6d1c27e24fa">Participant Object: ParticipantObjectIdentification</para>
                                    <para xml:id="para_af8cebf7-85e6-4bde-81a8-b3d25dca7a65">Study (0..N)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_25916b00-b55b-4963-926f-2899a82b2763">ParticipantObjectTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c42c5916-18c4-4033-b9f3-feec9906e245">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7883aa13-ae73-4571-872c-bd4c092e1cbb">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>2</term>
                                                <listitem>
                                                    <para xml:id="para_eb5c2226-cf86-415b-9a36-db59d19cfeca">System Object</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_71d2ed28-3c37-4f38-acc8-49ed6c155b93">ParticipantObjectTypeCodeRole</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4d25c4be-9f14-400d-a5f0-927713857b7e">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fc0e33fe-6dad-44a7-aeab-a8d6a8c6e0db">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>3</term>
                                                <listitem>
                                                    <para xml:id="para_17a4035f-9f3c-42f4-8649-52f614654182">Report</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_75ac898d-5e39-4623-b7c8-19c56d973693">ParticipantObjectDataLifeCycle</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e0186b7a-e374-4971-8602-f116bbe3e837">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3fea361b-3a1b-4c67-afe8-bb0635f1c4e8">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c36b8d2a-15b7-41db-93f0-065545a9470f">ParticipantObjectIDTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ec06f0f3-c7d1-44a0-8899-0c457f2167f1">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_297a1f4b-c805-4e1c-a38f-3ac650ec8068">EV <olink targetdoc="PS3.16" targetptr="DCM_110180">(110180, DCM, "Study Instance UID")</olink>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_742ea6a9-d73d-45a8-a961-e04f3aa675c9">ParticipantObjectSensitivity</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_16d6331b-e6a9-4324-bd73-3d19632b4ee4">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b878d117-40a0-4770-b5cd-c0edcbddd3d7">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3c912f0f-b819-47f9-a24e-23442d74b05c">ParticipantObjectID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_62bd7728-ed6d-45d2-ac82-80bf50079568">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2d1ab395-903c-4587-b56e-cd69e46d5844">The Study Instance UID.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5b773346-34b2-425e-8c84-92cd51c00041">ParticipantObjectName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4d348d2d-c82b-4001-ad58-e3b8338c629d">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_689a0f16-8c51-434b-9b70-ae9cb8dc987f">Required if ParticipantObjectQuery is not present.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_259fd3e6-f5c3-4a94-84b9-e3540e22fb0d">ParticipantObjectQuery</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_0a47469b-5609-4365-a078-7637f05c3440">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4d22b873-05b2-4a17-96c5-86f40d9f3866">Required if ParticipantObjectName is not present.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1c4813f0-d1e4-4435-b9c5-55b98c9fe71a">ParticipantObjectDetail</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_5dd082ff-f5ad-47f2-b7da-37fe8028af96">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5bdde4c2-82a7-46c3-ac25-bcdcedc80ff9">Not further specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_709c019d-f537-4e94-b708-20e6737a4a7b">ParticipantObjectDescription</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_5836d0dd-ed4f-4a74-97c0-f774e9663b0b">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_667965f2-a39b-4c53-8002-c80ad82ed39e">Not further specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a9e1567b-9a1e-43a1-8618-f05d591b2fab">SOPClass</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9b381c7d-6a15-4187-88c0-62e8f89f4c21">MC</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_bc728164-cfad-4857-9807-613faa5fa051">Not further specialized.</para>
                                    <para xml:id="para_30044f08-49f2-4892-9104-1918cc09331d">See <xref linkend="sect_A.5.2" xrefstyle="select: label"/> for conditions.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_198cc01c-04d5-43ef-9d0d-b9c55ad9d225">Accession</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_78c5d821-39f7-4f70-a88f-d40c79fd3ee8">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9668d8ce-86a4-47dd-9d14-540556082fdd">Not further specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3fca483f-081a-4871-b5eb-c072cd7ff76a">NumberOfInstances</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_1d127923-7c6d-474d-9930-0783dd8dc9e2">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ddd8dcc2-c5b2-4194-ace3-be418ffa41eb">Not further specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d0f79d49-d621-49e1-83f1-b242c5ae6ea0">Instances</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ebe1b9e6-77a0-491b-a2cb-9f69cfd2acad">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_72ec088d-9c08-4e81-968d-6c40ee8337ac">Not further specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_acfb2b7c-0f71-4e61-a4cf-dd38b344fcd6">Encrypted</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f255bcb7-db11-4ba1-b356-71a5e49502d0">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_768560c6-6d56-428a-b612-6bf0e2627996">Not further specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_345d3867-ba84-45d5-8756-58a5d6fb509e">Anonymized</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8c1d6edb-8aed-4e25-8c26-8331bab86fd4">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_073abbaf-d031-4a29-bbf0-5a5fd3cb403b">Not further specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="9">
                                    <para xml:id="para_e6ee599b-16a3-4620-98e4-fe3c7f8c933c">Participant Object: ParticipantObjectIdentification</para>
                                    <para xml:id="para_8efba30b-1bdc-488b-ad00-63e77cce4ed9">Patient (1)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a88fc56d-6422-417c-87f0-0e9067a9f030">ParticipantObjectTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_79e373fa-f3bb-4909-8e26-90be82e3f3b5">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_bffb2016-7fbe-4be9-af0a-5f8cdebaf280">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>1</term>
                                                <listitem>
                                                    <para xml:id="para_bf0ea9c0-19c2-4a8d-ab14-49bcada1781b">Person</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d2f5673a-abfd-4d60-9183-a5e97e38f4bf">ParticipantObjectTypeCodeRole</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_74886698-f100-40dd-922c-5a9a76d79843">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9a69fee7-7866-4ac3-a29e-7c7f72b47cb1">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>1</term>
                                                <listitem>
                                                    <para xml:id="para_608597ef-4218-4336-aa21-eb24b5ab3a1f">Patient</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_eaa6bac4-a8ac-4f58-93c1-936b6ce5be62">ParticipantObjectDataLifeCycle</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_feef5aa7-042e-4022-ba37-51626c7d1e9e">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e8666fc5-ca5e-429c-9d90-6c8a02db24b7">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f4ceac15-64c4-4209-a750-84327ecd477f">ParticipantObjectIDTypeCode</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8cb651b9-e489-41fb-b4d0-5e41e260c598">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2cfdbea6-7e0b-4834-9940-61a4121a4002">
                                        <variablelist spacing="compact">
                                            <title>Shall be:</title>
                                            <varlistentry>
                                                <term>2</term>
                                                <listitem>
                                                    <para xml:id="para_b667b0b2-4ec6-413e-b7a6-c8c36cf7f127">Patient Number</para>
                                                </listitem>
                                            </varlistentry>
                                        </variablelist>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d0c77f64-8f4f-4c66-95c9-05a36ed8bca0">ParticipantObjectSensitivity</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2f6ce95f-2baa-477a-9255-33f3079ee0d2">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_93b65dc7-13d4-4158-bb97-cf25a8f33b33">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ebbf4693-22cb-4545-bb5d-a61edeab7b6e">ParticipantObjectID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ee8ab76f-af4e-447f-8466-28032d94886b">M</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_541d55db-31cb-4378-8653-a09048b69f3a">The patient ID.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e8857502-fe50-4e00-bb70-08ecdce0e867">ParticipantObjectName</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_d4a2e5ff-1d3b-45a6-9ab3-22b6d22f04d6">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c50fbc62-b6be-44f7-a480-2132cbdf1e4e">The patient name.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_86448add-b1a1-421e-a51c-3b2ec7f7d369">ParticipantObjectDetail</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f034d8b4-f89c-47bf-93d5-51651ced1aa2">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_28de734c-50dc-41a1-98bd-6abd64750397">Not specialized.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8029a129-a1c0-4541-af2d-87749dfaa276">ParticipantObjectDescription</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f20c44f1-8bf6-4a19-82df-6ead1109f868">U</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2b498257-c468-42f0-8812-41108bffb501">Not further specialized.</para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                </section>

            </section>
        </section>
        <section label="A.6" status="2" xml:id="sect_A.6">
            <title>Audit Trail Message Transmission Profile - SYSLOG-TLS</title>

            <para xml:id="para_09d57897-eca4-4316-bb9d-d5c890d65d2a">This profile defines the transmission of audit trail messages. <xref linkend="biblio_RFC_5425"/> provides the mechanisms for reliable transport, buffering, acknowledgement, authentication, identification, and encryption. <xref linkend="biblio_RFC_5424"/> states that the TLS used MUST be TLS version 1.2. For this DICOM profile TLS MUST be used, and version 1.2 or later is RECOMMENDED.</para>
            <note>
                <para xml:id="para_5664cfde-d7c4-423e-84e0-afdd7ae8f847">The words MUST and RECOMMENDED are used in accordance with the IETF specification for normative requirements.</para>
            </note>
            <para xml:id="para_23569c75-5e1a-49fb-845a-2fba1ee28d70">Any implementation that claims conformance to this profile shall also conform to the Audit Trail Message Format Profile. XML audit trail messages created using the format defined in Audit Trail Message Format Profile shall be transmitted to a collection point using the syslog over TLS mechanism, defined in <xref linkend="biblio_RFC_5425"/>. Systems that comply with this profile shall support message sizes of at least 32768 octets.</para>
            <note>
                <orderedlist numeration="arabic">
                    <listitem>
                        <para xml:id="para_71175f35-37fd-4df9-a4ed-08d61d0974fb">Audit messages for other purposes may also be transferred on the same syslog connection. These messages might not conform to the Audit Trail Message Format.</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_2fe61cfa-7825-4df4-909e-172e4b910c48">
                            <xref linkend="biblio_RFC_5425"/> specifies mandatory support for 2KB messages, strongly recommends support for at least 8KB, and does not restrict the maximum size.</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_d03b0acf-8981-429b-b204-e841212a65a2">When a received message is longer than the receiving application supports, the message might be discarded or truncated. The sending application will not be notified.</para>
                    </listitem>
                </orderedlist>
            </note>
            <para xml:id="para_d275117b-0794-4395-a866-eaf0b27c4a02">The XML audit trail message shall be inserted into the MSG portion of the SYSLOG-MSG element of the syslog message as defined in <xref linkend="biblio_RFC_5424"/>. The XML audit message may contain Unicode characters that are encoded using the UTF-8 encoding rules.</para>
            <note>
                <para xml:id="para_1e01796a-916c-4065-ae3b-adbb746612c9">UTF-8 avoids utilizing the control characters that are reserved by the syslog protocol, but a system that is not prepared for UTF-8 may not be able to display these messages correctly.</para>
            </note>
            <para xml:id="para_e9fb7e42-c64e-45bc-b8e5-efee041fbb22">The PRI field shall be set using the facility value of 10 (security/authorization messages). Most messages should have the severity value of 5 (normal but significant), although applications may choose other values if that is appropriate to the more detailed information in the audit message. This means that for most audit messages the PRI field will contain the value "&lt;85&gt;".</para>
            <para xml:id="para_6d32aeb9-7ff0-416e-ab17-1a0afd1816a1">The MSGID field in the HEADER of the SYSLOG-MSG shall be set. The value "DICOM+RFC3881" may be used for messages that comply with this profile.</para>
            <para xml:id="para_b8a55fdd-0a95-423f-addc-ed02a0e661f5">The MSG field of the SYSLOG-MSG shall be present and shall be an XML structure following the DICOM Audit Message Schema (see <xref linkend="sect_A.5.1" xrefstyle="select: label"/>).</para>
            <para xml:id="para_7c3c0f0e-b0c1-4cff-9eef-09368f73b3ae">The syslog message shall be created and transmitted as described in <xref linkend="biblio_RFC_5424"/>.</para>
            <para xml:id="para_682c6207-727e-46af-8fb6-94cc1fc9bc26">Any implementation that claims conformance to this Security Profile shall describe in its conformance statement:</para>
            <orderedlist numeration="loweralpha">
                <listitem>
                    <para xml:id="para_ca8c0157-48f9-4e56-9d31-c273de126ea8">any configuration parameters relevant to <xref linkend="biblio_RFC_5424"/> and <xref linkend="biblio_RFC_5425"/>.</para>
                </listitem>
                <listitem>
                    <para xml:id="para_fd6e8ac2-e309-4405-83fd-45cb819770da">Any STRUCTURED-DATA that is generated or processed.</para>
                </listitem>
                <listitem>
                    <para xml:id="para_364342b2-693a-4e82-8cea-8c80a261ad70">Any implementation schema or message element extensions for the audit messages.</para>
                </listitem>
                <listitem>
                    <para xml:id="para_9d42a645-95b7-4885-88fd-ae9f38db7664">The maximum size of messages that can be sent or received.</para>
                </listitem>
            </orderedlist>
        </section>
        <section label="A.7" status="2" xml:id="sect_A.7">
            <title>Audit Trail Message Transmission Profile - SYSLOG-UDP</title>
            <para xml:id="para_8f91cf58-8cfd-4f32-b141-a5c00ad2c071">This profile defines the transmission of audit trail messages. <xref linkend="biblio_RFC_5426"/> provides the mechanisms for rapid transport of audit messages. It is the standardized successor to the informative standard <xref linkend="biblio_RFC_3164"/>, which is widely used in a variety of settings.</para>
            <para xml:id="para_e477d761-8878-4e0c-be41-ca4f2d51527c">The syslog port number shall be configurable, with the port number (514) as the default.</para>
            <para xml:id="para_e8649e42-cad6-4f90-9ab4-d07e8384a694">The underlying UDP transport might not accept messages longer than the MTU size minus the UDP header length. This may result in longer syslog messages being truncated. When these messages are truncated the resulting XML may be incorrect. Because of this potential for truncated messages and other security concerns, the transmission of syslog messages over TLS may be preferred (see <xref linkend="sect_A.6" xrefstyle="select: label"/>).</para>
            <para xml:id="para_f235e963-dfeb-4e2e-8e44-f73980f0187b">The PRI field shall be set using the facility value of 10 (security/authorization messages). Most messages should have the severity value of 5 (normal but significant), although applications may choose values of 4 (warning condition) if that is appropriate to the more detailed information in the audit message. This means that for most audit messages the PRI field will contain the value "&lt;85&gt;". Audit repositories shall be prepared to deal appropriately with any incoming PRI value.</para>
            <para xml:id="para_e5faa060-4af1-41ea-923e-e3ceed479b2d">The MSGID field in the HEADER of the SYSLOG-MSG shall be set. The value "DICOM+RFC3881" may be used for messages that comply with this profile.</para>
            <para xml:id="para_a89bdb4b-efcb-4bc0-8532-ffcec32cd8b9">The MSG field of the SYSLOG-MSG shall be present and shall be an XML structure following the DICOM Audit Message Schema (see <xref linkend="sect_A.5.1" xrefstyle="select: label"/>).</para>
            <para xml:id="para_826f25d8-71f8-4f3d-9784-2d5081ff2706">The syslog message shall be created and transmitted as described in <xref linkend="biblio_RFC_5424"/>.</para>
            <para xml:id="para_e22f58f0-913f-4f9d-bdfb-97e437aa6701">Any implementation that claims conformance to this Security Profile shall describe in its conformance statement:</para>
            <orderedlist numeration="loweralpha">
                <listitem>
                    <para xml:id="para_ce3f1478-37c8-41db-8853-f4a42e397ca6">any configuration parameters relevant to <xref linkend="biblio_RFC_5424"/> and <xref linkend="biblio_RFC_5426"/>.</para>
                </listitem>
                <listitem>
                    <para xml:id="para_b7ea17c4-6ed5-4494-950f-9c3252743e68">Any STRUCTURED-DATA that is generated or processed.</para>
                </listitem>
                <listitem>
                    <para xml:id="para_8f9a83b7-bca6-4e82-98f1-ddaff4c0a41e">Any implementation schema or message element extensions for the audit messages.</para>
                </listitem>
                <listitem>
                    <para xml:id="para_109012d4-b496-4efd-9d07-8126fc3a84fe">The maximum size of messages that can be sent or received.</para>
                </listitem>
            </orderedlist>
        </section>
    </chapter>
<chapter label="B" status="1" xml:id="chapter_B">
    <title>Secure Transport Connection Profiles (Normative)</title>
  
  <section label="B.1" status="2" xml:id="sect_B.1">
    <title>Basic TLS Secure Transport Connection Profile</title>
  
  <para xml:id="para_f2c5417b-2079-4288-891f-9bc9c4298f7c">Retired. See <link xl:href="http://dicom.nema.org/MEDICAL/Dicom/2018a/output/pdf/part15.pdf">PS3.3-2018a</link>.</para>
  </section>
<section label="B.2" status="2" xml:id="sect_B.2">
    <title>ISCL Secure Transport Connection Profile</title>
  
  <para xml:id="para_3711e6dc-7f2c-49f2-bd5b-ab5ee4cb50a2">Retired. See <link xl:href="http://dicom.nema.org/MEDICAL/Dicom/2018a/output/pdf/part15.pdf">PS3.3-2018a</link>.</para>
  </section>
    <section label="B.3" status="2" xml:id="sect_B.3">
    <title>AES TLS Secure Transport Connection Profile</title>
  
  <para xml:id="para_a4082a9b-ee9b-4df4-a568-cb4a60e77f56">Retired. See <link xl:href="http://dicom.nema.org/MEDICAL/Dicom/2018a/output/pdf/part15.pdf">PS3.3-2018a</link>.</para>
  </section>
    <section label="B.4" status="2" xml:id="sect_B.4">
    <title>Basic User Identity Association Profile</title>
  <para xml:id="para_15c19127-ce4b-4134-aee2-cc1dd84b8c76">An implementation that supports the Basic User Identity Association profile shall accept the User Identity association negotiation sub-item, for User-Identity-Type of 1 or 2. It need not verify the passcode. If a positive response is requested, the implementation shall respond with the association response sub-item.</para>
  <para xml:id="para_73159503-bf7a-48b7-a796-0655fe69a2d1">The user identity from the Primary-field shall be used within the implementation as the user identification. Such uses include recording user identification in audit messages.</para>
    <table frame="box" label="B.4-1" rules="all" xml:id="table_B.4-1">
      <caption>Minimum Mechanisms for DICOM Association Negotiation Features - Basic User Identity Association Profile</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_e7c34563-b52d-4e53-bef9-0aee11762c8e">Supported Association Negotiation Feature</para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_8c633e95-a9bb-40b6-9819-5faf9c749ea6">Minimum Mechanism</para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b0e5f88f-4aed-45e8-a4b5-e43fd4d71d9a">User Identity</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9c95b851-47d1-4476-ac12-41941d21d976">Username</para>
      </td>
    </tr>
  </tbody>
  </table>
  </section>
    <section label="B.5" status="2" xml:id="sect_B.5">
    <title>User Identity Plus Passcode Association Profile</title>
  
  <para xml:id="para_64108db8-f549-4be8-847c-94f668c7ad56">An implementation that supports the User Identity plus Passcode Association Profile shall send/accept the User Identity association negotiation sub-item, for User-Identity-Type of 2. If a positive response is requested, the association acceptor implementation shall respond with the association response sub-item. The passcode information shall be made available to internal or external authentication systems. The user identity shall be authenticated by means of the passcode and the authentication system. If the authentication fails, the association shall be rejected.</para>
  <para xml:id="para_df6c85e9-3d6d-4f1a-ad32-d5fb6d6483b7">The user identity from the Primary-field shall be used within the implementation as the user identification. Such uses include recording user identification in audit messages.</para>
    <table frame="box" label="B.5-1" rules="all" xml:id="table_B.5-1">
      <caption>User Identity Plus Passcode Association Profile - Minimum Mechanisms for DICOM Association Negotiation Features</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_1010434e-caaa-495b-aa39-d805a12ec2e5">Supported Association Negotiation Feature</para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_576bee08-8444-46cb-a4ac-9e5f90db9282">Minimum Mechanism</para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_ecf4e102-29b4-4a81-a6fd-c8dbbc44ee50">User Identity</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f8244aea-e71d-4135-b85b-46275da988f9">Username and Passcode</para>
      </td>
    </tr>
  </tbody>
  </table>
  </section>
<section label="B.6" status="2" xml:id="sect_B.6">
    <title>Kerberos Identity Negotiation Association Profile</title>
  
  <para xml:id="para_bc5efc26-7c5f-405c-aad7-2ff9468e9295">An implementation that supports the Kerberos Identity Negotiation Association Profile shall send/accept the User Identity association negotiation sub-item, for User-Identity-Type of 3. If a positive response is requested, the association acceptor implementation shall respond with the association response sub-item containing a Kerberos server ticket. The Kerberos server ticket information shall be made available to internal or external Kerberos authentication systems. The user identity shall be authenticated by means of the Kerberos authentication system. If the authentication fails, the association shall be rejected.</para>
  <para xml:id="para_2a4fb8fb-9a1a-4c01-8479-403bff3acb7b">The user identity from the Primary-field shall be used within the implementation as the user identification. Such uses include recording user identification in audit messages.</para>
    <table frame="box" label="B.6-1" rules="all" xml:id="table_B.6-1">
      <caption>Kerberos Identity Negotiation Association Profile - Minimum Mechanisms for DICOM Association Negotiation Features</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_9336f77d-c175-4407-ac73-5e7af1ef9210">Supported Association Negotiation Feature</para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_319e1494-de91-4136-8f30-ccf84ac8fec6">Minimum Mechanism</para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_cf35295a-31c0-493f-975b-c5efd9393972">User Identity</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e973e8a4-aa5e-4ac7-b89d-40c1365f52ef">Kerberos</para>
      </td>
    </tr>
  </tbody>
  </table>
  </section>
<section label="B.7" status="2" xml:id="sect_B.7">
    <title>Generic SAML Assertion Identity Negotiation Association Profile</title>
  
  <para xml:id="para_b7aa17f1-4254-4a30-83ad-e2b0259c0349">An implementation that supports the Generic SAML Assertion Identity Negotiation Association Profile shall send/accept the User Identity association negotiation sub-item, for User-Identity-Type of 4. If a positive response is requested, the association acceptor implementation shall respond with the association response sub-item containing a SAML response. The SAML Assertion information shall be made available to internal or external authentication systems. The user identity shall be authenticated by means of an authentication system that employs SAML Assertions. If the authentication fails, the association shall be rejected.</para>
  <para xml:id="para_4bdf8863-4800-4e3c-8102-eccd4cc1fd90">The user identity from the Primary-field shall be used within the implementation as the user identification. Such uses include recording user identification in audit messages.</para>
    <table frame="box" label="B.7-1" rules="all" xml:id="table_B.7-1">
      <caption>Generic SAML Assertion Identity Negotiation Association Profile - Minimum Mechanisms for DICOM Association Negotiation Features</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_f484ae44-bdeb-4f24-8d6c-f576089a5e6b">Supported Association Negotiation Feature</para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_7d4fff80-9ed1-496d-b850-a5e9a968ea0a">Minimum Mechanism</para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_40c90a6a-ff18-4f24-9bdb-b63beee1ab1e">User Identity</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_41fac02f-ee64-4032-a65f-e55dde027e02">SAML Assertion</para>
      </td>
    </tr>
  </tbody>
  </table>
  </section>
<section label="B.8" status="2" xml:id="sect_B.8">
    <title>Secure Use of Email Transport</title>
  
  <para xml:id="para_937c3281-ca14-4f16-a318-6b5d5272181d">When a DICOM File Set is sent over Email transport in compliance with this profile the following rules shall be followed:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_d7346797-e5dd-4135-8ecd-bbcd13c240e1">The File Set shall be an attachment to the email body.</para>
</listitem>
<listitem>
<para xml:id="para_6ee85f8b-41a3-4efc-9198-e151efac339d">The entire email (body, File Set attachment, and any other attachments) shall be encrypted using AES, in accordance with <xref linkend="biblio_RFC_3851"/> and <xref linkend="biblio_RFC_3853"/>.</para>
</listitem>
<listitem>
<para xml:id="para_d62c79c1-5eaf-4fd3-b21a-55dada0a3d7d">The email body and attachments may be compressed in accordance with <xref linkend="biblio_RFC_3851"/>.</para>
</listitem>
<listitem>
<para xml:id="para_ffeabc55-9352-4347-95de-f1aba4c6e378">The email shall be digitally signed by the sender. The signing may be applied before or after encryption. This digital signature shall be interpreted to mean that the sender is attesting to his authorization to disclose the information in this email to the recipient.</para>
</listitem>
</orderedlist>
  <para xml:id="para_167e137e-83ae-4880-93ed-983380782a3e">The email signature is present to provide minimum sender information and to confirm the integrity of the email transmission (body contents, attachment, etc.). The email signature is separate from other signatures that may be present in DICOM reports and objects contained in the File set attached to the email. Those signatures are defined in terms of clinical uses. Any clinical content attestations shall be encoded as digital signatures in the DICOM SOP instances, not as the email signature. The email may be composed by someone who cannot make clinical attestations. Through the use of the email signature, the composer attests that he or she is authorized to transmit the data to the recipient.</para>
  <note>
    <orderedlist numeration="arabic">
      <listitem>
        <para xml:id="para_29bc169f-d2d2-42a5-ac00-bff470cf62a5">This profile is separate from the underlying use of ZIP File or other File Set packaging over email.</para>
      </listitem>
      <listitem>
          <para xml:id="para_1728b634-f8ad-4aa8-aa9f-058b41ede788">Where private information is being conveyed, most country regulations require the use of encryption or equivalent protections. This Profile meets the most common requirements of regulations, but there may be additional local requirements. Additional requirements may include mandatory statements in the email body and prohibitions on contents of the email body to protect patient privacy.</para>
      </listitem>
    </orderedlist>
  </note>
  </section>
  <section label="B.9" status="2" xml:id="sect_B.9">
    <title>BCP 195 TLS Secure Transport Connection Profile</title>
      <para xml:id="para_999b2656-2b98-42fe-9594-0902e4613b44">Retired. See <link xl:href="http://dicom.nema.org/MEDICAL/Dicom/2022d/output/pdf/part15.pdf">PS3.3-2022d</link>.</para>
  </section>
  <section label="B.10" status="2" xml:id="sect_B.10">
    <title>Non-Downgrading BCP 195 TLS Secure Transport Connection Profile</title>
      <para xml:id="para_f58ca21b-9c2d-4e51-85d6-b5e7438b4219">Retired. See <link xl:href="http://dicom.nema.org/MEDICAL/Dicom/2022d/output/pdf/part15.pdf">PS3.3-2022d</link>.</para>
  </section>
    <section label="B.11" status="2" xml:id="sect_B.11">
        <title>Extended BCP 195 TLS Profile Secure Transport Connection Profile</title>
        <para xml:id="para_365d99a6-f379-4089-89b8-c2b9c8759cda">Retired. See <link xl:href="http://dicom.nema.org/MEDICAL/Dicom/2022d/output/pdf/part15.pdf">PS3.3-2022d</link>.</para>
    </section>
    <section label="B.12" status="2" xml:id="sect_B.12">
        <title>BCP 195 RFC 8996, 9325 TLS Secure Transport Connection Profile</title>
        <para xml:id="para_b601e6b2-b76e-4115-b858-45b840681313">An implementation that supports the BCP 195 RFC 8996, 9325 TLS Secure Transport Connection Profile shall utilize the framework and negotiation mechanism specified by the Transport Layer Security protocol.
            It shall comply with <xref linkend="biblio_BCP_195"/> which includes <xref linkend="biblio_RFC_8996"/>, and <xref linkend="biblio_RFC_9325"/>.
            In the context of this profile, “client” refers to the entity initiating the TLS connection and “server” refers to the entity that is responding to that TLS connection initiation request.
            This may differ from the role that the entity might play in any DICOM transactions over the TLS connection.</para>
        <note>
            <orderedlist>
                <listitem>
                    <para xml:id="para_da8f2456-5671-4fae-98cf-ad88ce01576b">A device may support multiple TLS profiles.
                        DICOM does not specify how such devices are configured in the field or how different TLS profile-related rules are specified.
                        The site will determine what configuration is appropriate.</para>
                </listitem>
                <listitem>
                    <para xml:id="para_9c1913cc-d942-4da2-aba1-02d2843be498">The DICOM profiles for TLS describe the capabilities of a product.
                        Product configuration may permit selection of a particular profile and/or additional negotiation rules.
                        The specific cipher suite used is negotiated by the TLS implementation based on these rules.</para>
                </listitem>
            </orderedlist>
        </note>
        <para xml:id="para_3154cbf7-883e-496b-996b-9868b6ad66f1">Servers and clients shall support TLS 1.2 and may support TLS 1.3.
            Clients shall attempt to negotiate TLS 1.3 if it is supported.
            Servers shall prefer TLS 1.3 if offered by the client.</para>
        <para xml:id="para_a2a28a06-df02-46d9-b493-bf539957e34c">In cases where an application protocol allows implementations or deployments a choice between strict TLS configuration and dynamic upgrade from unencrypted to TLS-protected traffic (such as STARTTLS), clients and servers shall prefer strict TLS configuration.</para>
        <para xml:id="para_942ccfe9-4587-4406-9aa9-786cbc5f845c">Application protocols typically provide a way for the server to offer TLS during an initial protocol exchange, and sometimes also provide a way for the server to advertise support for TLS (e.g., through a flag indicating that TLS is required).
            Unfortunately, these indications are sent before the communication channel is encrypted.</para>
        <para xml:id="para_15f31e69-7e09-4b1e-a3f8-71bdcce88002">A client shall attempt to negotiate TLS even if the above indications are not communicated by the server.</para>
        <para xml:id="para_9349e819-a57f-48d8-b145-c489189d9eb8">All communications shall be encrypted with integrity checks enabled.
            Hence, implementations shall not use NULL key exchange, cipher, or signature/hash protocols.</para>
        <para xml:id="para_4f9de3a0-9c92-45e9-a6f0-b78b562eb8d9">Servers shall support bi-directional mutual authentication.
            Clients are not required, but are encouraged, to support and use bi-directional mutual authentication.
            The server may be configured to not use bi-directional mutual authentication.</para>
        <para xml:id="para_bde8ef51-3459-4deb-8846-c0314046650b">The TCP ports on which an implementation accepts TLS connections for DICOMweb shall be different from those on which an implementation accepts TLS connections for DIMSE.
            The HTTP/HTTPS connection for DICOMweb can be shared with other HTTP/HTTPS traffic.</para>
        <note>
            <para xml:id="para_04a66a41-200e-4f54-a56d-7569a0a357f4">It is recommended that systems supporting this Profile use the registered port number "2762 dicom-tls" for the DICOM Upper Layer Protocol on TLS, which is used by DIMSE.</para>
        </note>
        <para xml:id="para_d619aa24-04d7-4747-a940-7eeafb56deb6">The Conformance Statement shall indicate:</para>
        <itemizedlist>
            <listitem>
                <para xml:id="para_61f2027c-a5e0-4807-a744-51380c803074">TCP ports on which an implementation accepts TLS connections, or the mechanism by which these port numbers are selected or configured </para>
            </listitem>
            <listitem>
                <para xml:id="para_7b448052-08b3-49d5-9a9f-5acf8c27cd0e">What mechanisms the implementation supports for Key Management.</para>
            </listitem>
            <listitem>
                <para xml:id="para_b5bd976c-b98a-4071-a3a9-077d5e8e7659">Which key exchange algorithms, cipher suites, and signature algorithms the implementation supports.</para>
            </listitem>
        </itemizedlist>
        <para xml:id="para_e260df92-d42f-4817-b33f-091c2f1d024e">When an integrity check fails, the connection shall be dropped per the TLS protocol, causing both the sender and the receiver to issue an A-P-ABORT indication to the upper layers with an implementation-specific provider reason.
            The Conformance Statement shall document the provider reasons issued by the implementation.</para>
    </section>
    <section label="B.13" status="2" xml:id="sect_B.13">
        <title>Modified BCP 195 RFC 8996, 9325 TLS Secure Transport Connection Profile</title>
        <para xml:id="para_6d462f1d-11ba-4b65-80c4-55bffa1f6d52">An implementation that supports the Modified BCP 195 RFC 8996, 9325 TLS Secure Transport Connection Profile shall utilize the framework and negotiation mechanism specified by the Transport Layer Security protocol.
            It shall comply with <xref linkend="biblio_BCP_195"/> which includes <xref linkend="biblio_RFC_8996"/>, and <xref linkend="biblio_RFC_9325"/> with the additional restrictions enumerated below.
            In the context of this profile, “client” refers to the entity initiating the TLS connection and “server” refers to the entity that is responding to that TLS connection initiation request.
            This may differ from the role that the entity might play in any DICOM transactions over the TLS connection.</para>
        <note>
            <orderedlist>
                <listitem>
                    <para xml:id="para_50eef9d3-d19f-483b-ac19-4bf86a993f36">A device may support multiple TLS profiles.
                        DICOM does not specify how such devices are configured in the field or how different TLS profile-related rules are specified.
                        The site will determine what configuration is appropriate.</para>
                </listitem>
                <listitem>
                    <para xml:id="para_716c4c45-ff68-41ef-a1a1-6905685ddc5f">The DICOM profiles for TLS describe the capabilities of a product.
                        Product configuration may permit selection of a particular profile and/or additional negotiation rules.
                        The specific cipher suite used is negotiated by the TLS implementation based on these rules.</para>
                </listitem>
            </orderedlist>
        </note>
        <para xml:id="para_209446fb-8662-4b1f-a540-5552e146a781">A client shall attempt to negotiate TLS even if the above indications are not communicated by the server.</para>
        <para xml:id="para_6af1c310-9ec0-417e-af4e-460d5b87535d">The following cryptographic algorithms, grouped by function, shall not be used:</para>
        <itemizedlist>
            <listitem>
                <para xml:id="para_c6a99ef8-a468-46f2-8155-3750c1abfcae">Key Exchange</para>
                <itemizedlist>
                    <listitem>
                        <para xml:id="para_ba8998cd-d37c-46b2-a1ac-cf20c9eff738">DH</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_e22f4a6c-d3fa-4199-a3ec-10e7e3550b6f">ECDH</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_52a58eee-d053-407b-b64f-e7b731ce7f4c">RSAES PKCS#1 v1.5 (RSA)</para>
                    </listitem>
                </itemizedlist>
            </listitem>
            <listitem>
                <para xml:id="para_6539a262-6c48-44d4-b8fb-d2efb660c44b">Signature</para>
                <itemizedlist>
                    <listitem>
                        <para xml:id="para_6d66d49b-eb2e-4999-9ffc-7f785aa209d3">GOST R 34.10-2012</para>
                    </listitem>
                </itemizedlist>
            </listitem>
            <listitem>
                <para xml:id="para_a99dec7f-5b92-44cc-88bd-8fab988a84f1">Block Cipher</para>
                <itemizedlist>
                    <listitem>
                        <para xml:id="para_cf5e3630-42d3-4f07-95d9-93ca6c92ae8c">RC2</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_dc90d1a3-8077-4a87-8644-393d5f3e5390">EXPORT-RC2</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_46214196-9628-4766-9bce-7e0944a45024">IDEA</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_f4725074-d3f7-4be9-b416-61467c938c9b">DES</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_2551b4c8-64b0-4f64-8921-e118f189eb9f">EXPORT-DES</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_6ee40545-647b-4b29-8359-2739efd603e2">GOST 28147-89</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_5d7dc15d-0f36-40d9-ab2b-c4810683029a">Magma</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_c6d9b426-0cc0-4d22-8e62-abb966152690">3-key Triple DES</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_4313b88b-5a9e-4a9a-877c-9af1a560bdb8">Kuznyechik</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_e064ebe7-73e1-4230-addf-0863be0df7fd">ARIA</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_352e678f-8d95-4ec6-af13-382f8fd2b553">SEED</para>
                    </listitem>
                </itemizedlist>
            </listitem>
            <listitem>
                <para xml:id="para_1131e70e-b212-4985-8d92-67bc1866ead2">Block Cipher Mode of Operation</para>
                <itemizedlist>
                    <listitem>
                        <para xml:id="para_5202a2e4-41e6-42ca-9dc3-e658871f6216">CBC</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_e771162c-9476-4088-bd86-5248af5b9a54">CTR-OMAC</para>
                    </listitem>
                </itemizedlist>
            </listitem>
            <listitem>
                <para xml:id="para_12abc62d-a3a1-4614-93e6-cf44b0332f0e">Stream Cipher</para>
                <itemizedlist>
                    <listitem>
                        <para xml:id="para_bb0669ad-eeae-428a-9ba2-887720d33513">RC4</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_3b135b00-d625-4018-b80b-6d1542e5a020">EXPORT-RC4</para>
                    </listitem>
                </itemizedlist>
            </listitem>
            <listitem>
                <para xml:id="para_c4cffe96-c7ad-47fd-84ca-e5dff54af6a6">Hash Function</para>
                <itemizedlist>
                    <listitem>
                        <para xml:id="para_eb6ccd4e-cf65-4aa3-a0e7-925a00ac1566">MD5</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_c80f394c-4e63-4ce2-991e-fa66f145b926">SHA-1</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_f9d39772-da39-4170-9e75-13b1db891e28">GOST R 34.11-2012</para>
                    </listitem>
                </itemizedlist>
            </listitem>
        </itemizedlist>
        <para xml:id="para_b2462ae3-12d9-46ee-91d7-e5e91ec49d3f">Only the following cryptographic algorithms, grouped by function, are permitted:</para>
        <itemizedlist>
            <listitem>
                <para xml:id="para_571b19a4-0b29-4f05-bbdb-e4133c439e9b">Key Exchange</para>
                <itemizedlist>
                    <listitem>
                        <para xml:id="para_1a610e67-47f9-4988-8f64-65bc84e717e3">ECDHE</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_212dd98a-7438-4182-aaa7-a8a24b16c6e4">DHE</para>
                    </listitem>
                </itemizedlist>
            </listitem>
            <listitem>
                <para xml:id="para_d85617e4-51c3-4491-b37f-18a572eeecd2">Signature</para>
                <itemizedlist>
                    <listitem>
                        <para xml:id="para_07ba0b38-781f-4f16-8f5c-eef4277ea2c4">ECDSA</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_96082e3e-3b4b-47a3-afc1-7e8cbe6be331">RSASSA PKCS#1 v1.5 (RSA)</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_aac1ce43-1f35-4784-9cf2-91f25049f9ce">RSASSA-PSS</para>
                    </listitem>
                </itemizedlist>
            </listitem>
            <listitem>
                <para xml:id="para_480e0712-cd05-473b-9bf2-25feff4a93d6">Block Cipher</para>
                <itemizedlist>
                    <listitem>
                        <para xml:id="para_a985d489-d807-4b69-95be-6c5a830dc6a4">AES</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_411cedd5-6331-4dda-9a3e-9a6335eb78dc">Camellia</para>
                    </listitem>
                </itemizedlist>
            </listitem>
            <listitem>
                <para xml:id="para_48217513-a536-4e94-af1d-91f67d9dbbb0">Block Cipher Mode of Operation</para>
                <itemizedlist>
                    <listitem>
                        <para xml:id="para_819f4ef8-6615-49f6-9887-79084ad3a55c">GCM</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_fe94d70b-2e1c-4577-9050-911b0faad707">CCM</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_d258e369-f53a-4aa2-a2b8-9406a8909da5">CCM_8</para>
                    </listitem>
                </itemizedlist>
            </listitem>
            <listitem>
                <para xml:id="para_1eda4d4c-f84b-4774-b0b7-76a564aa9dd8">Stream Cipher</para>
                <itemizedlist>
                    <listitem>
                        <para xml:id="para_9429457f-ee63-4c86-add4-8b01e255a322">ChaCha20-Poly 1305</para>
                    </listitem>
                </itemizedlist>
            </listitem>
            <listitem>
                <para xml:id="para_7a7b6e4d-9bb3-4ed1-84f5-6eb36b11ca5c">Hash Function</para>
                <itemizedlist>
                    <listitem>
                        <para xml:id="para_fe10206e-ea74-4f7c-ad34-6be6ed1ac12f">SHA-256</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_a7b0c1b7-8141-4700-8f93-ca4e100195bb">SHA-384</para>
                    </listitem>
                </itemizedlist>
            </listitem>
        </itemizedlist>
        <para xml:id="para_fd9862fd-4afb-4b92-a824-036db8f8c0a0">When DHE is used for Key Exchange, the key length shall be 2048 bits or more.
            Cipher suites containing DHE shall not be selected when using implementations that do not allow explicit setting of the DHE key length.</para>
        <para xml:id="para_d8f70a33-5f96-478b-ba4a-28d4dcacdaf3">When ECDHE is used for Key Exchange, the key length shall be 256 bits or more.</para>
        <para xml:id="para_72d12447-7a6a-40ff-9722-52e790cd3897">Servers shall support all of the following cipher suites for TLS 1.3.
            Clients that support TLS 1.3 shall support at least one of the following cipher suites.</para>
        <itemizedlist>
            <listitem>
                <para xml:id="para_c16f7954-a295-40b1-afb5-92e101b9be67">TLS_AES_256_GCM_SHA384</para>
            </listitem>
            <listitem>
                <para xml:id="para_644a6c11-b843-4367-9b65-b082204f1a8d">TLS_CHACHA20_POLY1305_SHA256</para>
            </listitem>
            <listitem>
                <para xml:id="para_4751b6b4-4914-4f8f-88c4-847e90999a37">TLS_AES_128_GCM_SHA256</para>
            </listitem>
            <listitem>
                <para xml:id="para_94d65ea4-8a9a-4a51-942c-f2ab869e4019">TLS_AES_128_CCM_SHA256</para>
            </listitem>
            <listitem>
                <para xml:id="para_4688658c-11c5-4c4e-9a5c-f7c818b0d101">TLS_AES_128_CCM_8_SHA256</para>
            </listitem>
        </itemizedlist>
        <note>
            <para xml:id="para_93413f5c-f1df-432f-9e09-dcc6a79f2d59">In TLS 1.3 Key Exchange and Signature, algorithms are not specified in the cipher suite negotiation.
                Implementations may choose from the list above of permitted algorithms.</para>
        </note>
        <para xml:id="para_929d1648-48b1-4ea9-b408-871c9e6d2d80">Servers shall support all of the following cipher suites for TLS 1.2. Clients shall support at least one of the cipher suites defined below.</para>
        <itemizedlist>
            <listitem>
                <para xml:id="para_8b739ff0-2707-4730-a134-f8ee027f6cdd">TLS_ECDHE_ECDSA_WITH_AES_256_GCM_SHA384</para>
            </listitem>
            <listitem>
                <para xml:id="para_1ef852b7-8b6b-44d9-bb61-425ea09a9a99">TLS_ECDHE_RSA_WITH_AES_256_GCM_SHA384</para>
            </listitem>
            <listitem>
                <para xml:id="para_d320d262-15a5-471e-83af-6f33fc8b96a5">TLS_ECDHE_ECDSA_WITH_AES_256_CCM</para>
            </listitem>
            <listitem>
                <para xml:id="para_5864d3eb-c5c8-4605-a39b-b179a1c227ef">TLS_ECDHE_ECDSA_WITH_AES_256_CCM_8</para>
            </listitem>
            <listitem>
                <para xml:id="para_199fb931-7848-4ef5-9607-0494f0db56b6">TLS_ECDHE_ECDSA_WITH_CHACHA20_POLY1305_SHA256</para>
            </listitem>
            <listitem>
                <para xml:id="para_0d78fc24-3991-48b7-a806-95db6190f345">TLS_ECDHE_RSA_WITH_CHACHA20_POLY1305_SHA256</para>
            </listitem>
            <listitem>
                <para xml:id="para_4d018084-0a29-45a3-9d2f-ce76d3e3fc8f">TLS_ECDHE_RSA_WITH_AES_128_GCM_SHA256</para>
            </listitem>
            <listitem>
                <para xml:id="para_e909c885-129a-4dc5-8ddd-bcd5a3000f1d">TLS_ECDHE_ECDSA_WITH_AES_128_GCM_SHA256</para>
            </listitem>
            <listitem>
                <para xml:id="para_791b6e63-bcf4-4ebb-a918-d9c88c0c74eb">TLS_ECDHE_ECDSA_WITH_AES_128_CCM</para>
            </listitem>
            <listitem>
                <para xml:id="para_09697186-e5a8-4192-a63d-89fd2285d89e">TLS_ECDHE_ECDSA_WITH_AES_128_CCM_8</para>
            </listitem>
        </itemizedlist>
        <para xml:id="para_4f822d8f-fc2d-4ce1-b8aa-0fcd6e169bd3">The following list of cipher suites may be used, but support is not mandatory for both servers and clients.</para>
        <itemizedlist>
            <listitem>
                <para xml:id="para_40bc17f5-a781-4895-9d44-574e5dab18fe">TLS_ECDHE_ECDSA_WITH_CAMELLIA_256_GCM_SHA384</para>
            </listitem>
            <listitem>
                <para xml:id="para_e28715b9-388d-4477-89c6-e8d6d28e5544">TLS_ECDHE_RSA_WITH_CAMELLIA_256_GCM_SHA384</para>
            </listitem>
            <listitem>
                <para xml:id="para_0ba9f993-3a5e-416e-91a7-46bb3b562c74">TLS_ECDHE_ECDSA_WITH_CAMELLIA_128_GCM_SHA256</para>
            </listitem>
            <listitem>
                <para xml:id="para_e63cb3a8-ed3a-45ff-b56a-66dc1260159d">TLS_ECDHE_RSA_WITH_CAMELLIA_128_GCM_SHA256</para>
            </listitem>
            <listitem>
                <para xml:id="para_d9212e18-9384-4f0d-a913-8f2469d4a888">TLS_DHE_RSA_WITH_AES_256_GCM_SHA384</para>
            </listitem>
            <listitem>
                <para xml:id="para_28cf5ee6-3225-4364-8f63-0b45860f9935">TLS_DHE_RSA_WITH_CAMELLIA_256_GCM_SHA384</para>
            </listitem>
            <listitem>
                <para xml:id="para_748cef4a-594e-4f27-a88e-14fe0854fe65">TLS_DHE_RSA_WITH_AES_256_CCM</para>
            </listitem>
            <listitem>
                <para xml:id="para_37b35aad-0cd7-4f3b-a208-a04a9f6d614e">TLS_DHE_RSA_WITH_AES_256_CCM_8</para>
            </listitem>
            <listitem>
                <para xml:id="para_690dc78e-1c97-440f-8649-a374ebe287ac">TLS_DHE_RSA_WITH_CHACHA20_POLY1305_SHA256</para>
            </listitem>
            <listitem>
                <para xml:id="para_66bec7d9-23e0-4646-a466-5ab6a27dd555">TLS_DHE_RSA_WITH_AES_128_GCM_SHA256</para>
            </listitem>
            <listitem>
                <para xml:id="para_fcd8a195-4cde-4bb2-8a6d-551fade1028d">TLS_DHE_RSA_WITH_CAMELLIA_128_GCM_SHA256</para>
            </listitem>
            <listitem>
                <para xml:id="para_411ef910-b0c5-4e8d-9087-8ffdc4f24839">TLS_DHE_RSA_WITH_AES_128_CCM</para>
            </listitem>
            <listitem>
                <para xml:id="para_d6d516dc-5489-4c2e-9b38-005a90903ff0">TLS_DHE_RSA_WITH_AES_128_CCM_8</para>
            </listitem>
        </itemizedlist>
        <para xml:id="para_fcf62f05-4fa6-41f4-9c0f-088c15580f44">When using TLS 1.2, cipher suites other than those listed in the required or optional lists above are not permitted.</para>
        <para xml:id="para_ad36c380-03ee-46a7-bc22-ecb3e6034218">The following requirements apply to Certificates within TLS:</para>
        <itemizedlist>
            <listitem>
                <para xml:id="para_4c5105fd-dd87-459e-a5a2-2f1cba2456c1">If the subject public key algorithm is RSA, the key length shall be 2048 bits or more.</para>
            </listitem>
            <listitem>
                <para xml:id="para_bda7f7b5-08b1-4454-99a0-528ab3e8d596">If the subject public key algorithm is ECC, the key length shall be 256 bits or more.</para>
            </listitem>
            <listitem>
                <para xml:id="para_cdca8146-5b7a-407c-a9d6-0cae009fc95a">If the certificate signature algorithm is RSA, the key length shall be 2048 bits or more.</para>
            </listitem>
            <listitem>
                <para xml:id="para_dce81645-df77-4ee4-8353-022ac2a1e9f4">If the certificate signature algorithm is ECDSA, the key length shall be 256 bits or more.</para>
            </listitem>
            <listitem>
                <para xml:id="para_fab68599-5a61-4d0e-96ac-3bf6bd879373">The hash function shall be SHA-256 or greater.</para>
            </listitem>
        </itemizedlist>
        <para xml:id="para_b0a8d104-bb98-4d2d-b88d-8e795c423311">Servers shall support both TLS 1.2 and TLS 1.3.
            Clients shall support at least one of TLS 1.2 or TLS 1.3.
            Clients shall attempt to negotiate TLS 1.3 if it is supported.
            Servers shall prefer TLS 1.3 if offered by the client.
            Implementations may fall back to TLS 1.2 if the client does not negotiate TLS 1.3.</para>
        <para xml:id="para_f8e5e85e-77c1-4b72-90e0-a1374c2fb2fb">In cases where an application protocol allows implementations or deployments a choice between strict TLS configuration and dynamic upgrade from unencrypted to TLS-protected traffic (such as STARTTLS), clients and servers shall prefer strict TLS configuration.</para>
        <para xml:id="para_17eb3943-44a7-4a4c-b246-f5a1ac69121a">Application protocols typically provide a way for the server to offer TLS during an initial protocol exchange, and sometimes also provide a way for the server to advertise support for TLS (e.g., through a flag indicating that TLS is required); unfortunately, these indications are sent before the communication channel is encrypted.</para>
        <para xml:id="para_c9dcfe41-49a2-429b-a8b4-cef559c5226a">Servers shall support bi-directional mutual authentication. Clients are not required, but are encouraged, to support and use bi-directional mutual authentication. The server may be configured to not use bi-directional mutual authentication.</para>
        <para xml:id="para_05aa7db2-a05d-4e5f-bb41-38315ca5f17f">The TCP ports on which an implementation accepts TLS connections for DICOMweb shall be different from those on which an implementation accepts TLS connections for DIMSE. The HTTP/HTTPS connection for DICOMweb can be shared with other HTTP/HTTPS traffic.</para>
        <note>
            <para xml:id="para_85d19904-4274-49df-9275-9a5e88f95581">It is recommended that systems supporting this Profile use the registered port number "2762 dicom-tls" for the DICOM Upper Layer Protocol on TLS.</para>
        </note>
        <para xml:id="para_a066a77a-eef3-4662-9faa-1e97f0c3d028">The Conformance Statement shall indicate:</para>
        <itemizedlist>
            <listitem>
                <para xml:id="para_aa963fa1-4538-4f08-bc1f-d3352d39939d">TCP ports on which an implementation accepts TLS connections, or the mechanism by which these port numbers are selected or configured </para>
            </listitem>
            <listitem>
                <para xml:id="para_691458aa-518c-4f32-8be7-459e7a7db4b6">What mechanisms the implementation supports for Key Management.</para>
            </listitem>
            <listitem>
                <para xml:id="para_1bc637e8-1b39-4f70-8488-ac5e83408c88">Which key exchange algorithms, cipher suites, and signature algorithms the implementation supports.</para>
            </listitem>
        </itemizedlist>
        <para xml:id="para_ff867b19-4ab8-4f14-aaa9-a3a6c5fe609c">When an integrity check fails, the connection shall be dropped per the TLS protocol, causing both the sender and the receiver to issue an A-P-ABORT indication to the upper layers with an implementation-specific provider reason.
            The Conformance Statement shall document the provider reasons issued by the implementation.</para>
    </section>
</chapter>
  <chapter label="C" status="1" xml:id="chapter_C">
    <title>Digital Signature Profiles (Normative)</title>

    <section label="C.1" status="2" xml:id="sect_C.1">
      <title>Base RSA Digital Signature Profile</title>
      <para xml:id="para_a060d5ff-e1de-45c4-8583-fdfe572a4452">The Base RSA Digital Signature Profile outlines the use of RSA encryption of a MAC to generate a Digital Signature. This Profile does not specify any particular set of Data Elements to sign. Other Digital Signature profiles may refer to this profile, adding specifications of which Data Elements to sign or other customizations.</para>
      <para xml:id="para_1499c309-bc72-4a02-bd0f-f94567158202">The creator of a digital signature shall use one of the RIPEMD-160, MD5, SHA-1 or SHA-2 family (SHA256, SHA384, SHA512) of hashing functions to generate a MAC, which is then encrypted using a private RSA key. All validators of digital signatures shall be capable of using a MAC generated by any of the hashing functions specified (RIPEMD-160, MD5, SHA-1 or SHA256, SHA384, SHA512).</para>
      <note>
        <para xml:id="para_a679419f-e24d-431e-8206-feadd996f817">The use of MD5 is not recommended by its inventors, RSA. See:ftp://ftp.rsasecurity.com/pub/pdfs/bulletn4.pdf</para>
      </note>
      <para xml:id="para_68a93cf3-a67a-4e55-8043-254be06350b8">The data to be signed shall be padded to a block size matching the RSA key size, as directed in <xref linkend="biblio_RFC_2437"/> (PKCS #1). The Value of MAC Algorithm (0400,0015) shall be set to either "RIPEMD160", "MD5", "SHA1", "SHA256", "SHA384" or "SHA512". The public key associated with the private key as well as the identity of the Application Entity or equipment manufacturer that owns the RSA key pair shall be transmitted in an <xref linkend="biblio_ITU-T_X.509"/> (1993) signature certificate. The Value of the Certificate Type (0400,0110) Attribute shall be set to "X509_1993_SIG". A site-specific policy determines how the <xref linkend="biblio_ITU-T_X.509"/> certificates are generated, authenticated, and distributed. A site may issue and distribute <xref linkend="biblio_ITU-T_X.509"/> certificates directly, may utilize the services of a Certificate Authority, or use any reasonable method for certificate generation and verification.</para>
        <para xml:id="para_73404a12-dfab-4acb-a939-c348f2211709">If an implementation utilizes timestamps, it shall use a Certified Timestamp Type (0400,0305) of "CMS_TSP". The Certified Timestamp (0400,0310) shall be generated as described in <xref linkend="biblio_RFC_3161"/>.</para>
    </section>
    <section label="C.2" status="2" xml:id="sect_C.2">
      <title>Creator RSA Digital Signature Profile</title>
      <para xml:id="para_82190a35-e1b3-40f7-b75f-33ad13a5160d">The creator of a DICOM SOP Instance may generate signatures using the Creator RSA Digital Signature Profile. The Digital Signature produced by this Profile serves as a lifetime data integrity check that can be used to verify that the pixel data in the SOP instance has not been altered since its initial creation. An implementation that supports the Creator RSA Digital Signature Profile may include a Creator RSA Digital Signature with every SOP Instance that it creates; however, the implementation is not required to do so.</para>
      <para xml:id="para_49b9b129-43f7-4e5a-acc9-77bd44af0c5f">The signature shall use one of the RIPEMD-160, MD5, SHA-1 or SHA-2 family (SHA256, SHA384, SHA512) of hashing functions to generate a MAC, which is then encrypted using a private RSA key. All validators of digital signatures shall be capable of using a MAC generated by any of the hashing functions specified (RIPEMD-160, MD5, SHA-1 or SHA256, SHA384, SHA512).</para>
      <note>
          <para xml:id="para_5c0672fa-8375-493e-9a54-252c6cda3ec6">Local rules and regulations may further restrict the hashing functions that are permitted.
              These regulations usually restrict the hashing functions that may be used by the SCP in creating a new signature on a new SOP Instance.
              For example, they may prohibit use of RIPEMD-160 and MD5.
              The regulations usually allow an SCU to verify an old signature that uses an algorithm that is now prohibited for new signatures.
              Implementations that support this profile will need to accommodate these local regulations.</para>
      </note>
      <para xml:id="para_8f18818f-89d4-4319-bea6-a640a30b0e7d">As a minimum, an implementation shall include the following Attributes in generating the Creator RSA Digital Signature:</para>
      <orderedlist numeration="loweralpha">
        <listitem>
          <para xml:id="para_eff5adfb-47c4-4586-958a-56af7e2149c0">the SOP Class and Instance UIDs</para>
        </listitem>
        <listitem>
          <para xml:id="para_124d1115-c028-4d7a-a58a-b606079c65b8">the SOP Creation Date and Time, if present</para>
        </listitem>
        <listitem>
          <para xml:id="para_133939f2-47f2-42d4-9c2b-9639267d79fc">the Study and Series Instance UIDs</para>
        </listitem>
        <listitem>
          <para xml:id="para_ae9dfe8a-983d-4eda-9b03-205bc63f6ba4">any Attributes of the General Equipment Module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_9d22aab4-e0d4-4875-9a9c-fa6085f4773d">any Attributes of the Overlay Plane Module, Curve Module or Graphic Annotation Module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_476761af-62ba-4bfa-b7ad-08ab067b67de">any Attributes of the <olink targetdoc="PS3.3" targetptr="sect_C.7.6.1" xrefstyle="template:%t"/> and <olink targetdoc="PS3.3" targetptr="sect_C.7.6.3" xrefstyle="template:%t"/> that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_322f28a4-807c-4b6d-9099-4547894de4ff">any Attributes of the SR Document General Module and SR Document Content Module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_add5b511-fe18-4c05-b677-74342c49f55b">any Attributes of the Waveform Module and Waveform Annotation Module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_fa6ddeed-6cdc-43d7-adc1-a3c57685d7e6">any Attributes of the Multi-frame Functional Groups Module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_b35cc0cd-2288-4ba2-981f-87fc4d3f14b7">any Attributes of the Enhanced MR Image Module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_b6f52a61-2d5f-40f9-b8d9-044a9f424614">any Attributes of the MR Spectroscopy Module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_bec58aec-305e-49d7-9d20-bb54095715e3">any Attributes of the Raw Data Module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_5ffdf4b4-13e8-42d5-873d-e47b29494025">any Attributes of the Enhanced CT Image Module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_3b39049c-ed60-4565-b27a-ae90330c2df1">any Attributes of the Enhanced XA/XRF Image Module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_23723a25-6beb-4919-ba07-b44db69ddbec">any Attributes of the Segmentation Image Module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_9baad955-20b6-45f8-8eb0-796f40ffedd1">any Attributes of the <olink targetdoc="PS3.3" targetptr="sect_C.24.1" xrefstyle="template:%t"/> that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_138209ad-6af8-4655-bf9c-f612ecf08603">any Attributes of the X-Ray 3D Image Module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_177ef893-16b2-4175-845a-d313ce2f2bff">any Attributes of the Enhanced PET Image Module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_5638c408-8513-48b0-92a9-d527ebcc9609">any Attributes of the Enhanced US Image Module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_49f40b13-c3cc-49b5-98a6-391129896cb8">any Attributes of the Surface Segmentation Module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_34c65a16-eb53-40d8-8be7-5cab846fcf9f">any Attributes of the Surface Mesh Module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_8951789e-452a-4822-af6f-93a9925829e9">any Attributes of the Structured Display Module, Structured Display Annotation Module, and Structured Display Image Box Module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_2bc0e80c-e81f-44e7-ab92-36c32ccf1e94">any Attributes of the Implant Template Module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_dfae80f6-f413-4f1e-b374-9fe19f9806e8">any Attributes of the Implant Assembly Template Module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_0ae7da20-1242-42ed-8f19-dccd8641b848">any Attributes of the Implant Template Group Module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_63759b2e-3dc0-40a5-80eb-2e61df0054ab">any Attributes of the Point Cloud Module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_d5533c9d-1e14-43b4-9ab2-0c0cbf514200">any Attributes of the Enhanced Mammography Image Module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_a6c1eede-c6dc-4de6-9f45-dfbe0bb2f47a">any Attributes of the <olink targetdoc="PS3.3" targetptr="sect_C.8.33" xrefstyle="template:%t"/> that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_f8bc28ff-78e3-4ed6-ad3a-0e2a7ee440df">any Attributes of the <olink targetdoc="PS3.3" targetptr="sect_C.11.28" xrefstyle="template:%t"/> that are present</para>
        </listitem>
        <listitem>
            <para xml:id="para_c3decd6b-a347-4d75-8584-fb67d4c6858a">any Attributes of the <olink targetdoc="PS3.3" targetptr="sect_C.37.1.2" xrefstyle="template:%t"/> that are present</para>
        </listitem>
          <listitem>
              <para xml:id="para_9f537709-9b07-4eb5-99dd-2d96f380eae4">any Attributes of the <olink targetdoc="PS3.3" targetptr="sect_C.39.1" xrefstyle="template:%t"/> that are present</para>
          </listitem>
          <listitem>
              <para xml:id="para_673a0813-7e1e-46b4-98b8-d164973fe612">any Attributes of the <olink targetdoc="PS3.3" targetptr="sect_C.39.2" xrefstyle="template:%t"/> that are present</para>
          </listitem>
          <listitem>
              <para xml:id="para_a0f584eb-7215-4ecf-b255-1cbc6015eb5a">any Attributes of the <olink targetdoc="PS3.3" targetptr="sect_C.39.3" xrefstyle="template:%t"/> that are present</para>
          </listitem>
          <listitem>
              <para xml:id="para_b41240d5-cb93-4024-bae6-65dc73bb012e">any Attributes of the <olink targetdoc="PS3.3" targetptr="sect_C.39.4" xrefstyle="template:%t"/> that are present</para>
          </listitem>
          <listitem>
              <para xml:id="para_a6cda592-cfc8-4744-aa10-c5349dc52b2b">any Attributes of the <olink targetdoc="PS3.3" targetptr="sect_C.39.5" xrefstyle="template:%t"/> that are present</para>
          </listitem>
          <listitem>
              <para xml:id="para_749b1051-4d6d-4b76-ab77-7060cd859ef6">any Attributes of the <olink targetdoc="PS3.3" targetptr="sect_C.39.6" xrefstyle="template:%t"/> that are present</para>
          </listitem>
      </orderedlist>
      <note>
          <para xml:id="para_bafa5d3d-0809-43e4-ba80-88470c27a93f">The requirement is upon Attributes, and the use of Modules in the list above is for documentation brevity.
              For example, a SOP instance of an <olink targetdoc="PS3.3" targetptr="sect_A.85.1" xrefstyle="template:%t"/> will have all of the Attributes of the <olink targetdoc="PS3.3" targetptr="sect_C.24.1" xrefstyle="template:%t"/> (used to encapsulate the STL file) signed.
              It will also have the Attributes used in any icon images signed, because the icon images use Attributes that are also Attributes of the <olink targetdoc="PS3.3" targetptr="sect_C.7.6.1" xrefstyle="template:%t"/> and <olink targetdoc="PS3.3" targetptr="sect_C.7.6.3" xrefstyle="template:%t"/>.
              The <olink targetdoc="PS3.3" targetptr="sect_C.7.6.1" xrefstyle="template:%t"/> and <olink targetdoc="PS3.3" targetptr="sect_C.7.6.3" xrefstyle="template:%t"/> are not incorporated the <olink targetdoc="PS3.3" targetptr="sect_A.85.1" xrefstyle="template:%t"/> and do not appear in the <olink targetdoc="PS3.3" targetptr="table_A.85.1-1" xrefstyle="template:%t"/> table.</para>
      </note>
      <para xml:id="para_bdfa36f8-af1f-447c-943f-048dd7d91e62">The Digital Signature shall be created using the methodology described in the Base RSA Digital Signature Profile. Typically the certificate and associated private key used to produce Creator RSA Digital Signatures are configuration parameters of the Application Entity set by service or installation engineers.</para>
        <para xml:id="para_658f2755-a6bc-4c70-9d05-1c62634ec01d">The SCP may include other attributes when generating the Creator RSA Digital Signature, and the SCU shall support verification of such signatures.</para>
        <para xml:id="para_b59bdc0f-fa98-43e8-a5b7-1bb537ce2977">Creator RSA Digital Signatures bear no direct relationship to other Digital Signatures.
            However, other Digital Signatures, such as the Authorization Digital Signature, may be used to collaborate the timestamp of a Creator RSA Digital Signature.</para>
    </section>
    <section label="C.3" status="2" xml:id="sect_C.3">
      <title>Authorization RSA Digital Signature Profile</title>
      <para xml:id="para_0993d3ee-bf1d-487d-8e67-8e6651a60aa6">The technician or physician who approves a DICOM SOP Instance for use may request the Application Entity to generate a signature using the Authorization RSA Digital Signature Profile. The Digital Signature produced serves as a lifetime data integrity check that can be used to verify that the pixel data in the SOP instance is the same that the technician or physician saw when they made the approval.</para>
        <para xml:id="para_a4d9a0d3-3f23-496f-8210-4be44d2d5512">The signature shall use one of the RIPEMD-160, MD5, SHA-1 or SHA-2 family (SHA256, SHA384, SHA512) of hashing functions to generate a MAC, which is then encrypted using a private RSA key. All validators of digital signatures shall be capable of using a MAC generated by any of the hashing functions specified (RIPEMD-160, MD5, SHA-1 or SHA256, SHA384, SHA512).</para>
      <para xml:id="para_d7c78584-6223-42de-a5eb-a43238f3bb16">As a minimum, an implementation shall include the following Attributes in generating the Authorization RSA Digital Signature:</para>
      <orderedlist numeration="loweralpha">
        <listitem>
          <para xml:id="para_4ce0002b-e0c1-47b4-a61a-5a19a785e04e">the SOP Class and Instance UIDs</para>
        </listitem>
        <listitem>
          <para xml:id="para_d7331c59-8d36-41e6-ab47-1537b508da6d">the Study and Series Instance UIDs</para>
        </listitem>
        <listitem>
          <para xml:id="para_bcec97d1-d6ea-4ecc-b992-ab4e8f58e685">any Attributes whose Values are verifiable by the technician or physician (e.g., their Values are displayed to the technician or physician)</para>
        </listitem>
        <listitem>
          <para xml:id="para_62cf1e1d-6d0e-4b04-a323-2baebe510eb5">any Attributes of the Overlay Plane, Curve or Graphic Annotation modules that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_44eb97d8-ffeb-44a7-a0c5-1cd150cf73fc">any Attributes of the General Image and Image Pixel modules that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_efe97309-c32a-457a-a126-8b4e4de343c0">any Attributes of the SR Document General and SR Document Content modules that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_a95735fe-874b-4b46-9428-ac38abbd203b">any Attributes of the Waveform and Waveform Annotation modules that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_2f2f132b-c96e-4da5-8a32-b9a166138537">any Attributes of the Multi-frame Functional Groups module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_2cd70324-85d3-41e3-9b99-98e105b03c34">any Attributes of the Enhanced MR Image module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_2cbd5f91-9fce-4387-8d5a-3fe86386b578">any Attributes of the MR Spectroscopy modules that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_c71e086a-e793-4b9a-a28e-513104db3bb2">any Attributes of the Raw Data module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_67d6fb2f-8019-494b-b6e7-60dbbcda3822">any Attributes of the Enhanced CT Image module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_1cc0b8a8-57b3-47d9-a014-3214a447b4f2">any Attributes of the Enhanced XA/XRF Image module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_6e8e74e6-0f7d-4bb3-b8df-a54b4d3261f4">any Attributes of the Segmentation Image module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_611cd8eb-4231-45e7-8ae9-7c37756704c8">any Attributes of the Encapsulated Document module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_65b6c7d3-9444-4509-9d79-c43e81e0e3ee">any Attributes of the X-Ray 3D Image module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_b1668cac-1b9b-4bef-9f11-ae4517742693">any Attributes of the Enhanced PET Image module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_8a457fb4-5858-4c24-8593-4d0b5c1a4c5c">any Attributes of the Enhanced US Image module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_6e582794-9fa3-4211-b0de-1e24ebffaee8">any Attributes of the Surface Segmentation module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_0bb8239a-09aa-40a5-b9aa-b6c9619200ce">any Attributes of the Surface Mesh Module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_1668ee78-9626-41b1-82ec-a61ad0fa0eae">any Attributes of the Structured Display, Structured Display Annotation, and Structured Display Image Box modules that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_0b3afca6-2ac7-480f-9c58-ba220f34e59f">any Attributes of the Implant Template module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_5be2b96e-4253-4bfb-8006-d5d8d4106f0a">any Attributes of the Implant Assembly Template module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_eebb723c-2b91-4610-bc3e-f4b53e99d1a3">any Attributes of the Implant Template Group module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_6f4606ae-23e9-4027-835b-edf316bd79cf">any Attributes of the Point Cloud Module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_b031487c-918d-4f87-bbc2-07888ecefa1d">any Attributes of the Enhanced Mammography Image module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_c1231dd2-cca5-4e6f-8150-16c16289e26d">any Attributes of the <olink targetdoc="PS3.3" targetptr="sect_C.11.28" xrefstyle="template:%t"/> that are present</para>
        </listitem>
      </orderedlist>
      <para xml:id="para_e07aabe9-bf80-45e1-81cf-3f87565e2af1">The Digital Signature shall be created using the methodology described in the Base RSA Digital Signature Profile. The Application Entity shall determine the identity of the technician or physician and obtain their certificate through a site-specific procedure such as a login mechanism or a smart card.</para>
      <para xml:id="para_114637ca-1634-417e-af01-5743cc6e682f">Authorization RSA Digital Signatures bear no direct relationship to other Digital Signatures. However, other Digital Signatures, such as the Creator RSA Digital Signature, may be used to collaborate the timestamp of an Authorization RSA Digital Signature.</para>
    </section>
    <section label="C.4" status="2" xml:id="sect_C.4">
      <title>Structured Report RSA Digital Signature Profile</title>

      <para xml:id="para_bd99e2f7-0a9f-44b1-afe1-c6cdb33bc926">This profile defines a mechanism for adding Digital Signatures to Structured Reports or Key Object Selection Documents where there is no more than one Verifying Observer. Instances that follow this Digital Signature Profile shall include at least one Digital Signature at the top level of the Data Set.</para>
      <para xml:id="para_6dea6710-2c43-45bc-b9f8-03fd73818d1f">All Digital Signatures that follow this profile shall include a Digital Signature Purpose Code Sequence Attribute (0400,0401).</para>
      <para xml:id="para_991bd328-9b96-4078-aaae-0c58cc475733">As a minimum, an implementation shall include the following Attributes in generating the Digital Signature required by this profile:</para>
      <orderedlist numeration="loweralpha">
        <listitem>
          <para xml:id="para_920eb836-8ad0-4d2a-a90c-b670e160b91e">the SOP Class UID</para>
        </listitem>
        <listitem>
          <para xml:id="para_7997d4e6-6675-4629-94a1-8256a5d89722">the Study and Series Instance UIDs</para>
        </listitem>
        <listitem>
          <para xml:id="para_5e3de7fc-d959-437e-b9eb-ef2b5f83177f">all Attributes of the General Equipment Module that are present</para>
        </listitem>
        <listitem>
          <para xml:id="para_762ee465-007c-44e4-8626-47a72e67758d">the Current Requested Procedure Evidence Sequence</para>
        </listitem>
        <listitem>
          <para xml:id="para_87ee97ce-15e4-4d15-8a1a-7ede69c4fa0e">the Pertinent Other Evidence Sequence</para>
        </listitem>
        <listitem>
          <para xml:id="para_5a5d7cca-0781-4999-a860-0172c7673410">the Predecessor Documents Sequence</para>
        </listitem>
        <listitem>
          <para xml:id="para_c400e4df-e36b-4175-a4ea-050cb4782cc3">the Observation DateTime</para>
        </listitem>
        <listitem>
          <para xml:id="para_31117d49-4944-41e4-b40e-80376727bb77">all Attributes of the SR Document Content Module that are present</para>
        </listitem>
      </orderedlist>
      <para xml:id="para_0f55c5fd-56c9-4c82-9ba5-558b4921af76">If the Verification Flag is set to "VERIFIED" (and the SOP Instance UID can no longer change) at least one of the Digital Signatures profile shall have the purpose of (5, ASTM-sigpurpose, "Verification Signature") and shall also include the following Attributes in addition to the above Attributes:</para>
      <orderedlist numeration="loweralpha">
        <listitem>
          <para xml:id="para_a6bf8371-c9cd-4032-a4b9-d827dec914a6">the SOP Instance UID</para>
        </listitem>
        <listitem>
          <para xml:id="para_8a893420-5bed-4d28-8b0f-904b93c6372f">the Verification Flag</para>
        </listitem>
        <listitem>
          <para xml:id="para_c3ddd8f9-4f91-4047-beee-5dcc2cc7d3c6">the Verifying Observer Sequence</para>
        </listitem>
        <listitem>
          <para xml:id="para_a5ae70e3-b2d2-4e0a-b4f2-2ac7f55f0ed8">the Verification DateTime</para>
        </listitem>
      </orderedlist>
      <note>
        <para xml:id="para_fe4c3329-9251-49b7-92a7-67b19be547ff">The system may also add a Creator RSA Digital Signature, which could cover other Attributes that the machine can verify.</para>
      </note>
      <para xml:id="para_dc5de5c3-ddfe-4ede-96d6-776ece55fa92">All occurrences of Referenced SOP Instance MAC Sequence (0400,0403) shall have the Value of MAC Algorithm (0400,0015) set to either "RIPEMD160", "MD5", "SHA1", "SHA256", "SHA384" or "SHA512"..</para>
      <para xml:id="para_f84ff2f1-282a-445d-9c25-8034fcc842a1">The Digital Signature shall be created using the methodology described in the Base RSA Digital Signature Profile. The Application Entity shall determine the identity of the signatories and obtain their certificate through an application-specific procedure such as a login mechanism or a smart card. The conformance statement shall specify how the application identifies signatories and obtains certificates.</para>
      <note>
        <para xml:id="para_72c1dfec-15ba-4317-b177-afad10ad0ae7">Structured Report RSA Digital Signatures bear no direct relationship to other Digital Signatures. However, other Digital Signatures, such as the Creator RSA Digital Signature, may be used to corroborate the timestamp of a Structured Report RSA Digital Signature.</para>
      </note>

    </section>
  </chapter>
<chapter label="D" status="1" xml:id="chapter_D">
    <title>Media Storage Security Profiles (Normative)</title>
  
  <section label="D.1" status="2" xml:id="sect_D.1">
    <title>Basic DICOM Media Security Profile</title>
  
  <para xml:id="para_4c4e3d70-14bf-4e49-8fce-02969078f2d4">The Basic DICOM Media Security Profile allows encapsulation of a DICOM File into a Secure DICOM File such that the following aspects of security are addressed:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_b2d3099c-e87d-4939-a719-d927d2021db6">confidentiality,</para>
</listitem>
  <listitem>
<para xml:id="para_e35602fe-e51b-4051-ab42-c9584d289aeb">integrity,</para>
</listitem>
  <listitem>
<para xml:id="para_6012692c-a23d-4c78-9414-4ea16a529fd8">data origin authentication (optional).</para>
</listitem>
</itemizedlist>
<para xml:id="para_6c470a5e-4878-4ae9-9b47-a5737dcdee38">This profile specifies the use of either AES or Triple-DES for content encryption and RSA, or password-based encryption and AES or Triple-DES, for the key transport of the content-encryption keys. The encrypted content is a DICOM File that can either</para>
<itemizedlist>
  <listitem>
<para xml:id="para_e38391c2-5e3d-4e87-8139-d780f7925b14">be signed with one or more digital signatures, using SHA-1, SHA256, SHA384, or SHA512 as the digest algorithm and RSA as the signature algorithm, or</para>
</listitem>
  <listitem>
<para xml:id="para_a3cfffae-85ba-4753-9bf5-2f3d8fab9160">be digested with SHA-1, SHA256, SHA384, or SHA512 as digest algorithm, without application of digital signatures.</para>
</listitem>
</itemizedlist>
<note>
    <para xml:id="para_ee2ba1f3-c131-473e-9f61-53d4df8a6069">The digest algorithm requirements will evolve as the threats evolve. As the digest requirements have changed, this profile has changed to include additional requirements.</para>
  </note>
  <section label="D.1.1" status="3" xml:id="sect_D.1.1">
    <title>Encapsulation of A DICOM File in a Secure DICOM File</title>
  
      <para xml:id="para_cb472c66-70ca-45fd-9a45-4889f167ed7e">A Secure DICOM File conforming to this security profile shall contain an Enveloped-data content type of the Cryptographic Message Syntax defined in IETF STD 70 <xref linkend="biblio_RFC_5652"/>, <xref linkend="biblio_RFC_3370"/> and <xref linkend="biblio_RFC_3565"/>. The enveloped data shall use RSA <xref linkend="biblio_RFC_3447"/>, or password-based encryption using PBKDF2 <xref linkend="biblio_RFC_2898"/> for the key derivation algorithm and either AES or Triple-DES <xref linkend="biblio_RFC_3211"/>, for the key transport of the content-encryption keys. Creators of a Secure DICOM File conforming to this security profile may use either AES or Triple-DES for content-encryption. Readers claiming conformance to this profile shall be capable of decrypting Secure DICOM Files using either AES or Triple-DES. The AES key length may be any length allowed by the RFCs. The Triple-DES key length is 168 bits as defined by <xref linkend="biblio_ANSIX9.52"/>. Encoding shall be performed according to the specifications for RSA Key Transport and Triple DES Content Encryption in <xref linkend="biblio_RFC_3370"/>, and for AES Content Encryption in <xref linkend="biblio_RFC_3565"/>.</para>
  <para xml:id="para_53d860aa-cd3d-4599-8f5a-054c01596339">The encrypted content of the Enveloped-data content type shall be of the following choices:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_089ee38f-971c-4c23-bb30-0b2abf636296">Signed-data content type;</para>
</listitem>
  <listitem>
<para xml:id="para_957e38f9-56d3-457a-a641-987f80ecd8d3">Digested-data content type.</para>
</listitem>
</itemizedlist>
      <para xml:id="para_7cc1bbb8-fcb0-4e52-aac1-7f0c14c323d5">In both cases, SHA-1 <xref linkend="biblio_FIPS_180-1"/>, SHA256, SHA384, or SHA512 <xref linkend="biblio_FIPS_180-2"/> shall be used as the digest algorithm. In case of the Signed-data content type, RSA <xref linkend="biblio_RFC_2313"/> shall be used as the signature algorithm.</para>
  <para xml:id="para_ecf84ba0-c931-42e0-b377-47629228e291">In the case of password-based encryption using PBKDF2, the octet string that contains the password used to generate the key shall be limited to the encoding and the graphic character representation defined by the Default Character Repertoire.</para>
  <note>
    <orderedlist numeration="arabic">
      <listitem>
        <para xml:id="para_293df03f-4f50-4eca-9612-9eadf1b16cf3">RSA key transport of the content-encryption keys is specified as a requirement in the European Prestandard ENV 13608-2: Health Informatics - Security for healthcare communication - Part 2: Secure data objects.</para>
      </listitem>
      <listitem>
        <para xml:id="para_452e37e1-f3e4-4e59-96e0-241f0473234c">No requirements on the size of the asymmetric key pairs used for RSA key transport are defined in this profile.</para>
      </listitem>
      <listitem>
        <para xml:id="para_17adc060-ae93-47e4-a98c-ab2c72286ec6">No requirements or restrictions on the use of the SignedAttributes element of the Signed-data content type's SignerInfo structure are defined in this profile. SignedAttributes might for example be used to specify the signing time or SMIME capabilities, as required by ENV 13608-2.</para>
      </listitem>
      <listitem>
        <para xml:id="para_fc6e1360-6f44-40f3-8f86-3e3232275d79">The use of password-based encryption for key transport of content encryption keys is potentially less secure than certificate-based encryption, but may be useful when the list of recipients is not known a priori or when there is no public key infrastructure deployed. The security depends on the entropy of the password, which if user-selected can be quite low. <xref linkend="biblio_RFC_3211"/> strongly recommends the use of a pass "phrase" rather than a single word, and <xref linkend="biblio_RFC_2898"/> does not impose any practical length limit. Also, the method used to exchange the password or pass phrase also could have a significant impact on the level of security.</para>
      </listitem>
      <listitem>
        <para xml:id="para_19ec7036-7683-41df-8d08-740b9fc8c014">PBKDF2 as defined in <xref linkend="biblio_RFC_2898"/> specifies the password to be "an octet string of arbitrary length whose interpretation as a text string is unspecified". For interoperability between the sender and recipient, both a character encoding scheme and a graphic character representation needs to be defined. ISO IR6 (US-ASCII), being the Default Character Repertoire for DICOM (see <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>), is specified in order to avoid any potential ambiguity caused by the use of other character sets (such as UTF-8) that do not necessarily result in the same binary values for particular graphic character representation.</para>
      </listitem>
    </orderedlist>
  </note>
  <para xml:id="para_355cc32b-295d-47b0-b33f-2c0add1db0ec">The graphic character representation of certain symbols in ISO IR6 is explicitly defined, even though the same binary representation may have a different graphic character representation in other 7-bit schemes. For example, in the version of ISO 646 used in Japan (ISO-IR 14 Romaji), 05/12 is represented as "¥" rather than backslash "\". It is the responsibility of the application to assure that the input method and display of such symbols to the user is mapped to the correct encoding, regardless of locale. I.e., if the password is "123\$", then it should be encoded as 03/01 03/02 03/03 05/12 02/04, regardless of whether the user types the backslash "\"(U+005C) on a Japanese or US keyboard; they should not be expected to type the "¥" (U+00A5) key on a Japanese keyboard, nor should 05/12 be displayed as "¥" if the password is displayed as text.</para>
  <para xml:id="para_81db47ea-256d-41da-bdf3-065f4e9f3c4e">The restriction to the ISO IR 6 encoding and graphic character representation (rather than, for example, the minimal encoding of UTF-8) also eliminates the ambiguity introduced by homographs (characters that look the same but encode differently), and alternative encodings with the same meaning, such as the single German character "ß" (U+00DF) as opposed to the two-character "ss" (U+0073 U+0073), and the use of phonetic as opposed to ideographic representation of the same meaning, such as Japanese hiragana "ぞう" (U+305E U+3046) versus kanji "像" (U+50CF).</para>
  <para xml:id="para_f21cb947-6327-49f8-9191-f297190b6b94">It is the responsibility of the application to prevent the user from creating passwords using characters that cannot be represented; e.g., on a Western European keyboard, the user should not be permitted to enter an accented character such as "é" (U+00E9) or "ö" (U+00F6), since there is no defined mapping of such characters to IS IR 6 characters (such as "e" or "o").</para>
  
  </section>
</section>
</chapter>
    <chapter label="E" status="1" xml:id="chapter_E">
        <title>Attribute Confidentiality Profiles (Normative)</title>
        <para xml:id="para_d0a89423-60be-4542-8aaf-081c416d8ff4">This Annex addresses the removal and replacement of Attributes within a DICOM Data Set that may potentially result in leakage of Individually Identifiable Information (III) about the patient or other individuals or organizations associated with the data.</para>
        <note>
            <para xml:id="para_c29609dd-fbfe-4b73-a44f-25f90be13b0c">Use of the Attribute Confidentiality Profiles does not guarantee that all individually identifying information will be removed,
                i.e., de-identification of the Attributes does not imply de-identification of the Information Object.
                Use of these profiles does not replace a de-identification process, but should be part of it.
                The description of such a process is beyond the scope of DICOM,
                but would at least involve determining the context of the de-identification
                (e.g., for what purpose is the data de-identified, who are the recipients, how is the de-identified data shared),
                interpreting the applicable regulations, and assessing the risk of detrimental re-identification.</para>
        </note>
        <para xml:id="para_8565fbc1-12bb-488e-8eba-452645b96345">The Profiles are provided to address the balance between the removal of information and the need to retain information so that the Data Sets remain useful for their intended purpose.</para>
        <para xml:id="para_a6c391b0-c9c8-4e1e-9bcc-1bf31d1a9396">Options are used in addition to the Profiles to prevent a combinatorial expansion of different Profiles.</para>
        <section label="E.1" status="2" xml:id="sect_E.1">
            <title>Application Level Confidentiality Profile</title>
            <para xml:id="para_bf0b34bf-7b49-4630-a893-33aa27bedf95">The Application Level Confidentiality Profile addresses the following aspects of security:</para>
            <itemizedlist>
                <listitem>
                    <para xml:id="para_175bf352-8b54-4816-a8e9-7bfb63493afc">Data Confidentiality at the application layer.</para>
                </listitem>
            </itemizedlist>
            <para xml:id="para_9d08e138-1680-484f-bc40-7c443dccec14">Other aspects of security not addressed by this Profile, that may be addressed elsewhere in the Standard, include:</para>
            <itemizedlist>
                <listitem>
                    <para xml:id="para_0f9c08ce-46aa-4063-aaa0-aa9c2ab2bf0e">Confidentiality in other layers of the DICOM model;</para>
                </listitem>
                <listitem>
                    <para xml:id="para_39d7bcce-9b14-4b11-9a9a-cae7a455d83e">Data Integrity.</para>
                </listitem>
            </itemizedlist>
            <para xml:id="para_e0b844f9-26f9-40e6-aaa3-cac91095f326">This Profile is targeted toward creating a special purpose, de-identified version of an already-existing Data Set. It is not intended to replace the original SOP Instance from which the de-identified SOP Instance is created, nor is it intended to act as the primary representation of clinical Data Sets in image archives. The de-identified SOP Instances are useful, for example, in creating teaching or research files, performing clinical trials, or submission to registries where the identity of the patient and other individuals is required to be protected. In some cases, it is also necessary to provide a means of recovering identity by authorized personnel.</para>
            <section label="E.1.1" status="3" xml:id="sect_E.1.1">
                <title>De-identifier</title>
                <para xml:id="para_4611a9c4-5846-41ea-8015-87e4bac046f0">An Application may claim conformance to the Basic Application Level Confidentiality Profile and Options as a de-identifier if it protects and retains <emphasis role="italic">all</emphasis> Attributes as specified in the Profile and Options. Protection in this context is defined as the following process:</para>
                <orderedlist numeration="arabic">
                    <listitem>
                        <para xml:id="para_a5c1cb67-16cf-4947-ab7f-252cc9a18562">The application may create one or more instances of the Encrypted Attributes Data Set and copy Attributes to be protected into the (single) item of the Modified Attributes Sequence (0400,0550) of one or more of the Encrypted Attributes Data Set instances.</para>
                        <note>
                            <orderedlist numeration="arabic">
                                <listitem>
                                    <para xml:id="para_3e4cc6a5-22f5-4bb6-925d-0b6f47a1b9d5">A complete reconstruction of the original Data Set may not be possible; however, Attributes (e.g., SOP Instance UID) in the Modified Attributes Sequence of an Encrypted Attributes Data Set may refer back to the original SOP Instance holding the original Data Set.</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_1f4ccf2f-441e-4f33-ad14-04f19b2b430c">It is not required that the Encrypted Attributes Data Set be created; indeed, there may be circumstances where the de-identified Data Set is expected to be archived long enough that any contemporary encryption technology may be inadequate to provide long term protection against unauthorized recovery of identification.</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_e5397e0c-30ec-4c4b-a9fb-d4114b594eee">Other mechanisms to assist in identity recovery or longitudinal consistency of replaced UIDs or dates and times are deprecated in favor of the Encrypted Attributes Data Set mechanism that is intended for this purpose. For example, if it is desired to include an encrypted hash of the Patient's Name, it should not be encoded in a separate Private Data Element implemented for that purpose, but should be included in the Encrypted Attributes Data Set and encoded using the standard mechanism. This allows for compatibility between different implementations and provides security based on the quality and control of the encryption keys. Note also, that unencrypted hashes are considerably less secure and should be avoided, since they are vulnerable to trivial dictionary based attacks.</para>
                                </listitem>
                            </orderedlist>
                        </note>
                    </listitem>
                    <listitem>
                        <para xml:id="para_daa1954b-9af4-4bad-aa35-41690a97fc7f">Each Attribute to be protected shall then either be removed from the Data Set, or have its value replaced by a different "replacement value" that does not allow identification of the patient.</para>
                        <note>
                            <orderedlist numeration="arabic">
                                <listitem>
                                    <para xml:id="para_9361f1da-c62c-4fb5-85a9-de904417b25f">It is the responsibility of the de-identifier to ensure that this process does not negatively affect the integrity of the Information Object Definition, i.e., Dummy values may be necessary for Type 1 Attributes that are protected but may not be sent with zero length, and are to be stored or exchanged in encrypted form by applications that may not be aware of the security mechanism.</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_bdcc66b5-7280-46e4-b7c1-7e0e4f4d9878">The Standard does not mandate the use of any particular dummy value, and indeed it may have some meaning, for example in data that may be used for teaching purposes, where the real patient identifying information is encrypted for later retrieval, but a meaningful alternative form of identification is provided. For example, a dummy Patient's Name (0010,0010) may convey the type of pathology in a teaching case. It is the responsibility of the de-identifier software or human operator to ensure that the dummy values cannot be used to identify the patient.</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_63cc8579-a4ec-45ec-b57c-136c01c8b93f">It is the responsibility of the de-identifier to ensure the consistency of dummy values for Attributes such as Study Instance UID (0020,000D) or Frame of Reference UID (0020,0052) if multiple related SOP Instances are protected. Indeed, all Attributes of every entity about the Instance level should remain consistent for all Instances protected, e.g., Patient ID for the Patient entity, Study ID for the Study entity, Series Number for the Series entity.</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_087a2fb7-7b8b-45a9-9059-f4d619ec252b">If an Attribute to be protected is contained in a Sequence of Items, the complete Sequence of Items may need to be protected.</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_05fc6b00-d0f1-4d43-99be-db772157fd28">The de-identifier should ensure that no identifying information that is burned in to the image pixel data either because the modality does not generate such burned in identification in the first place, or by removing it through the use of the Clean Pixel Data Option; see <xref linkend="sect_E.3" xrefstyle="select: label"/>. If non-pixel data graphics or overlays contain identification, the de-identifier is required to remove them, or clean them if the Clean Graphics Option is supported. See <xref linkend="sect_E.3.3" xrefstyle="select: label"/> The means by which burned in or graphic identifying information is located and removed is outside the scope of this Standard.</para>
                                </listitem>
                            </orderedlist>
                        </note>
                    </listitem>
                    <listitem>
                        <para xml:id="para_08a36063-841b-4499-9a4e-8501cc83acae">Each Attribute specified to be retained shall be retained. At the discretion of the de-identifier, Attributes may be added to the Data Set to be protected.</para>
                        <note>
                            <para xml:id="para_2e0eed2c-6478-4b68-bbea-9be92de1e992">As an example, the Attribute Patient's Age (0010,1010) might be introduced as a replacement for Patient's Birth Date (0010,0030) if the patient's age is of importance, and the selected Options permit it.</para>
                        </note>
                    </listitem>
                    <listitem>
                        <para xml:id="para_1c3d937e-b42b-4cd7-80db-092f09622605">If used, all instances of the Encrypted Attributes Data Set shall be encoded with a DICOM Transfer Syntax, encrypted, and stored in the Data Set to be protected as an Item of the Encrypted Attributes Sequence (0400,0500). The encryption shall be done using RSA <xref linkend="biblio_RFC_2313"/> for the key transport of the content-encryption keys. A de-identifier conforming to this security Profile may use either AES or Triple-DES for content-encryption. The AES key length may be any length allowed by the RFCs. The Triple-DES key length is 168 bits as defined by <xref linkend="biblio_ANSIX9.52"/>. Encoding shall be performed according to the specifications for RSA Key Transport and Triple DES Content Encryption in <xref linkend="biblio_RFC_3370"/> and for AES Content Encryption in <xref linkend="biblio_RFC_3565"/>.</para>
                        <note>
                            <orderedlist numeration="arabic">
                                <listitem>
                                    <para xml:id="para_d89221e7-5ad5-4034-b50e-8a4defd4f2d6">Each item of the Encrypted Attributes Sequence (0400,0500) consists of two Attributes, Encrypted Content Transfer Syntax UID (0400,0510) containing the UID of the Transfer Syntax that was used to encode the instance of the Encrypted Attributes Data Set, and Encrypted Content (0400,0520) containing the block of data resulting from the encryption of the Encrypted Attributes Data Set instance.</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_1f775454-2e20-4539-8581-1166bdd38751">RSA key transport of the content-encryption keys is specified as a requirement in the European Prestandard ENV 13608-2: Health Informatics - Security for healthcare communication - Part 2: Secure data objects.</para>
                                </listitem>
                            </orderedlist>
                        </note>
                    </listitem>
                    <listitem>
                        <para xml:id="para_bf62b269-f6b0-4598-ab70-36dec5b54ea5">No requirements on the size of the asymmetric key pairs used for RSA key transport are defined in this confidentiality scheme. Implementations claiming conformance to the Basic Application Level Confidentiality Profile as a de-identifier shall always protect (e.g., encrypt and replace) the SOP Instance UID (0008,0018) Attribute as well as all references to other SOP Instances, whether contained in the main Data Set or embedded in an Item of a Sequence of Items, that could potentially be used by unauthorized entities to identify the patient.</para>
                        <note>
                            <para xml:id="para_7fd12844-21ac-4759-80e1-d95bc5dff937">In the case of a SOP Instance UID embedded in an Item of a Sequence, this means that the enclosing Attribute in the top-level Data Set must be encrypted in its entirety.</para>
                        </note>
                    </listitem>
                    <listitem>
                        <para xml:id="para_7a8255cd-d599-4fca-9414-99cca6ed47a7">The Attribute Patient Identity Removed (0012,0062) shall be replaced or added to the Data Set with a value of YES. Additionally, one or more codes from <olink targetdoc="PS3.16" targetptr="sect_CID_7050" xrefstyle="select: labelnumber quotedtitle"/> corresponding to the Profile and Options used shall be added to De-identification Method Code Sequence (0012,0064), and/or a text string describing the method used shall be inserted in or added to De-identification Method (0012,0063).</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_41258edc-da3a-43bb-ae04-3734051a876b">If the Data Set being de-identified is being stored within a DICOM File, then the File Meta Information including the 128 byte preamble, if present, shall be replaced with a description of the de-identifying application. Otherwise, there is a risk that identity information may leak through unmodified File Meta Information or preamble. See <olink targetdoc="PS3.10" targetptr="PS3.10" xrefstyle="select: labelnumber"/>. This includes information regarding Application Entity Titles, Presentation Addresses, implementation information, and private information.</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_3f2a2e5f-92da-442a-847e-232d77a14d9d">If the Data Set being de-identified is being communicated by DICOM Real-Time Video, then the File Meta Information including the 128 byte preamble, if present, shall be replaced with a description of the de-identifying application. Otherwise, there is a risk that identity information may leak through unmodified File Meta Information or preamble. See <olink targetdoc="PS3.22" targetptr="PS3.22" xrefstyle="select: labelnumber"/>. This includes information regarding Application Entity Titles, Presentation Addresses, implementation information, and private information.</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_04d7f07b-6ab7-4580-9294-c8bb7cbfec9e">All Data Elements with a Group Number of 0004 shall be removed from any SOP Instance or DICOM File other than a DICOMDIR File. If a DICOMDIR File is required, it shall either be created from the de-identified DICOM Files it references, or an existing DICOMDIR File shall be de-identifed according to this Profile. Any existing non-de-identified DICOMDIR File shall be removed from the File-set.</para>
                    </listitem>
                </orderedlist>
                <para xml:id="para_3980cc0a-c52c-4abd-bb2d-5598fedad2ea">The Attributes listed in <xref linkend="table_E.1-1" xrefstyle="select: label"/> for each Profile or Option are contained in Standard IODs, or may be contained in Standard Extended IODs. An implementation claiming conformance to the Basic Application Level Confidentiality Profile as a de-identifier shall protect or retain all instances of the Attributes listed in <xref linkend="table_E.1-1" xrefstyle="select: label"/>, whether contained in the top level Data Set or embedded in an Item of a Sequence of Items. The action codes in <xref linkend="table_E.1-1a" xrefstyle="select: label"/> are used in <xref linkend="table_E.1-1" xrefstyle="select: label"/>.</para>
                <table frame="box" label="E.1-1a" rules="all" xml:id="table_E.1-1a">
                    <caption>De-identification Action Codes</caption>
                    <tbody>
                        <tr valign="top">
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4e504171-7b98-4d99-8a3a-b2758aab66d7">D</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4763e0d1-e6ff-45a5-9f42-7f75f9554e1d">replace with a non-zero length value that may be a dummy value and consistent with the VR</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fd24d97d-23f6-4501-96a7-c1461dd52c95">Z</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6214a285-c67d-4a99-ad8b-2c6bf18f0c39">replace with a zero length value, or a non-zero length value that may be a dummy value and consistent with the VR</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ed9861d2-4498-4121-a3eb-9628b593e9d8">X</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82ed9fd0-230c-4c2d-b04e-1bdb0a044b2b">remove Attribute, and if the Attribute is a Sequence, remove all Sequence Items and their contained Attributes</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fbe5199b-4714-419f-80ea-d994e86d9285">K</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d43d1f9a-b938-4493-9cb3-16b6d55d0779">keep (unchanged for non-Sequence Attributes, cleaned for Sequences)</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a56dd8b8-5676-4ac7-bb6f-925ff7f93659">C</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51acec2f-bd2c-4074-b97f-163c4eedf18a">clean, that is replace with values of similar meaning known not to contain identifying information and consistent with the VR</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b82d65d-6c5f-49d9-8ba2-1e9e0d3d9162">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9df2af8a-807b-4c04-9de4-e90be43b41f4">replace with a non-zero length UID that is internally consistent within a set of Instances</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a83a10bc-0018-491e-afda-bc9e7f4925f5">Z/D</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ddd71ecc-b0dd-44a6-9448-043cd5727d52">Z unless D is required to maintain IOD conformance (Type 2 versus Type 1)</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_309733fb-ae78-4350-89cc-3d33ccc3af70">X/Z</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_690037e7-7fda-4c09-89e7-70b1002500aa">X unless Z is required to maintain IOD conformance (Type 3 versus Type 2)</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_07369f32-ec19-4676-aa25-4d529527b0d6">X/D</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_589beabd-ebc6-4aca-a89f-ba413f39cdd1">X unless D is required to maintain IOD conformance (Type 3 versus Type 1)</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5c9b5a0d-e7ef-4a71-9593-5879e5f8552f">X/Z/D</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_755a1839-d49c-4bba-885c-208d5ea1f58c">X unless Z or D is required to maintain IOD conformance (Type 3 versus Type 2 versus Type 1)</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c038be6e-f307-4410-bfa9-55fae7f271cd">X/Z/U*</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31daf4f1-a39a-4795-a7db-20394737321c">X unless Z or replacement of contained instance UIDs (U) is required to maintain IOD conformance (Type 3 versus Type 2 versus Type 1 sequences containing UID references)</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_99cf130c-86d0-4eef-9460-9962ac07f7bb">These action codes are applicable to both Sequence and non-Sequence Attributes; in the case of Sequences, the action is applicable to the Sequence and all of its contents. Cleaning a sequence ("C" action) entails changing values of Attributes within that Sequence when the meaning of the Sequence within the context of its use in the IOD is specified, or recursively applying the Profile rules to each Data Set in each Item of the Sequence otherwise. Keeping a Sequence ("K" action) requires recursively applying the Profile rules to each Data Set in each Item of the Sequence (for example, in order to remap any UIDs contained within that sequence).</para>
                <para xml:id="para_85507f78-806f-4866-8c58-cc9bea84c73d">A requirement for an Option, when implemented, overrides any requirement for the underlying Profile. This will make de-identification retain or remove more information.</para>
                <note>
                    <orderedlist numeration="arabic">
                        <listitem>
                            <para xml:id="para_04c19a7c-01b0-4571-af8c-507762d99183">The Attributes listed in <xref linkend="table_E.1-1" xrefstyle="select: label"/> may not be sufficient to guarantee confidentiality of patient identity. In particular, identifying information may be contained in Private Attributes, new Standard Attributes, Retired Standard Attributes and additional Standard Attributes not present in Standard Composite IODs (as defined in <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>) but used in Standard Extended SOP Classes. <xref linkend="table_E.1-1" xrefstyle="select: label"/> indicates those Attributes that are used in Standard Composite IODs as well as those Attributes that are Retired. Also included in <xref linkend="table_E.1-1" xrefstyle="select: label"/> are some Elements that are not normally found in a Data Set, but are used in Commands, Directories and Meta Information Headers, but that could be misused within Private
                                Sequences. Textual Content Items of Structured Reports, textual annotations of Presentation States, Curves and Overlays are specifically addressed. It is the responsibility of the de-identifier to ensure that all identifying information is removed.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_29be0bb4-623f-456a-a734-ab13761f181a">It should be noted that conformance to the Basic Application Level Confidentiality Profile does not necessarily guarantee confidentiality. For example, if an attacker already has access to the original images, the Pixel Data could be matched, though the probability and impact of such a threat may be deemed to be negligible. If the Encrypted Attributes Sequence is used, it should be understood that any encryption scheme may be vulnerable to attack. Also, an organization's Security Policy and Key Management policy are recognized to have a much greater impact on the effectiveness of protection.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_06fff7ea-e844-4bf5-b661-b0e3ab77868e">National and local regulations, which may vary, might require that additional Attributes be de-identified, though the Profile and Options have been designed to be sufficient to satisfy known regulations without compromising the usefulness of the de-identified instances for their intended purpose.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_ea8cd55f-62a1-40d5-9a0a-68601e1ea9c5">
                                <xref linkend="table_E.1-1" xrefstyle="select: label"/> is normative, but it is subject to extension as the DICOM Standard evolves and other similar Attributes are added to IODs. De-identifiers may take this extensibility into account, for example, by considering handling all dates and times on the basis of their Value Representation of DT, DA or TM, rather than just those date and time Attributes lists.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_cb422d17-9059-48bd-903e-8b7924ed1e0e">The Profile and Options do not specify whether the design of a de-identifier should be to remove what is known to be a risk of identity leakage, or to retain only what is known to be safe. The former approach may fail when the Standard is extended, or when a vendor adds unanticipated Standard Attributes or Private Attributes, whilst the latter requires an extensive, if not complete, comparison of each instance with the Information Object Definitions in <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/> to avoid discarding required or useful information. <xref linkend="table_E.1-1" xrefstyle="select: label"/> defines the minimum actions required for conformance.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_99c2fa77-5eb5-450b-af86-d824af51939d">De-identification of Private SOP Classes is not defined.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_0a5b01ac-bb77-43c5-8904-246f31eca8fa">The "C" (clean) action is specified not only for string VRs, but also for Code Sequences, since the use of private or local codes and non-standard code meanings may potentially cause identity leakage.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_35ab5254-3f4d-4f5f-a4e3-e7a87362d4b5">The Digital Signatures Sequence (FFFA,FFFA) needs to be removed because it contains the Certificate of Signer (0400,0115); theoretically the signature could be verified and the object re-signed by the de-identifier itself with its own certificate, but this is not required by the Standard.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_54bfbe2f-4e52-4090-80b0-cf3e419ef6d9">In general, there are no CS VR Attributes in this table, since it is usually safe to assume that code strings do not contain identifying information.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_d0913a6e-9386-42b2-b2b3-e87c84cdb304">In general, there are no Code Sequence Attributes in this table, since it is usually safe to assume that coded sequence entries, including private codes, do not contain identifying information. Exceptions are codes for providers and staff.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_86a35705-5d27-4d26-aa8c-c385f93e0d92">The Clean Pixel Data and Clean Recognizable Visual Features Options are not listed in this table, since they are defined by descriptions of operations on the Pixel Data itself. The Clean Pixel Data Option may be applied to the Pixel Data within the Icon Image Sequence, or more likely the Icon Image Sequence may be recreated entirely once the Pixel Data of the main Data Set has been cleaned. The Icon Image Sequence is to be removed when its Pixel Data cannot be cleaned.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_d83088cb-3fae-48ae-9858-598416a330fd">The Original Attributes Sequence (0400,0561) (which in turn contains the Modified Attributes Sequence (0400,0550) ) generally needs to be removed, because it may contain unencrypted copies of other Attributes that may have been modified (e.g., coerced to use local identifiers and names during import of foreign images); an alternative approach would be to selectively modify its contents. This is distinct from the use of the Modified Attributes Sequence (0400,0550) within the Encrypted Attributes Sequence (0400,0500).</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_a5498f7d-fdc6-40d1-8bac-6386fd8c61d8">
                                <xref linkend="table_E.1-1" xrefstyle="select: label"/> distinguishes Attributes that are in standard Composite IODs defined in <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/> from those that are not; some Attributes are defined in <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/> for other IODs, or have a specific usage other than in the top level Data Set of a Composite IOD, but are (mis-) used by implementers in instances as a Standard Extended SOP Class at other levels than as defined by the Standard. Any such Attributes encountered may be removed without compromising the conformance of the instance with the standard IOD. For example, Verifying Observer Sequence (0040,A073) is only defined in structured report IODs and hence is described in <xref linkend="table_E.1-1" xrefstyle="select: label"/> as D since it is Type 1C; if encountered in an image instance, it should simply be removed (treated
                                as X).</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_529954ca-03b5-4df9-a09c-2a3de129bb28">Using an Attribute Confidentiality Profile Option that requires the retention of information that normally would be removed, potentially increases the risk of detrimental re-identification. Following de-identification rules as outlined here implies retention or non-retention of information only and does not deal with any related regulatory aspect.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_bdc8438a-760e-48b5-acca-5d22eb0eb3f9">Because of the varied nature of encapsulated documents (CDA, PDF, STL/OBJ, etc.), options for cleaning the content of the Encapsulated Document (0042,0011) Attribute are not specified by the Standard, and it is required to be replaced. If a De-identifier has additional knowledge of the content it may attempt to clean the Attribute, and document in its Conformance Statement how this is performed.</para>
                        </listitem>
                    </orderedlist>
                </note>
                <table frame="box" label="E.1-1" rules="all" xml:id="table_E.1-1">
                    <caption>Application Level Confidentiality Profile Attributes</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c5e6e8ba-34e0-4e31-90b5-bd9ed7086ddd">
                                    <emphasis role="bold">Attribute Name</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d02d5580-8438-4a00-8c30-ba93530bcd31">
                                    <emphasis role="bold">Tag</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_705936dc-2c42-4198-b406-ba0e61b35e99">
                                    <emphasis role="bold">Retd. (from <olink targetdoc="PS3.6" targetptr="PS3.6" xrefstyle="select: labelnumber"/>)</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a8387cac-386f-4ad9-96b3-b3dcb1b1010c">
                                    <emphasis role="bold">In Std. Comp. IOD (from <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>)</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fc0ff9a1-5780-4d06-861a-24ae0ba38b47">
                                    <emphasis role="bold">Basic Prof.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_19ddb67a-a5d6-474d-a13f-8df27d28b707">
                                    <emphasis role="bold">Rtn. Safe Priv. Opt.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5b335431-5276-4cc0-bddf-93b6d107226e">
                                    <emphasis role="bold">Rtn. UIDs Opt.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8317e0cf-0080-48f9-8040-1f49a4478c0f">
                                    <emphasis role="bold">Rtn. Dev. Id. Opt.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ba661a2-a572-420a-95c1-bc1bf694a70e">
                                    <emphasis role="bold">Rtn. Inst. Id. Opt.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_796841da-6b27-4558-99c9-99503edccc6c">
                                    <emphasis role="bold">Rtn. Pat. Chars. Opt.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_edac8181-290b-4f9c-945d-5dfc7b1a43fc">
                                    <emphasis role="bold">Rtn. Long. Full Dates Opt.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6305752d-56e7-4f4d-b9d8-e5052fcd6eea">
                                    <emphasis role="bold">Rtn. Long. Modif. Dates Opt.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_84f3b128-8fe5-45bc-b04e-abc483377b06">
                                    <emphasis role="bold">Clean Desc. Opt.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0adc5d55-1196-4265-8ee1-b205103c96f1">
                                    <emphasis role="bold">Clean Struct. Cont. Opt.</emphasis>
                                </para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5e74e547-b6fd-410e-9c09-b271915c3eeb">
                                    <emphasis role="bold">Clean Graph. Opt.</emphasis>
                                </para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7656f7bc-287c-47b2-ad02-914b402b6b51">Accession Number</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7138d32a-2d94-4948-a80e-08f7a7ceca23">(0008,0050)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_44726b33-0b55-4c8c-9217-035cc42bdda6">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c92bf277-400a-4b75-9563-db0562225519">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6409f35b-fca0-40bb-9cb3-4697885ed819">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7030df90-c342-4de7-94a5-dd1835a009cc">Acquisition Comments</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c4127628-e3f8-4e9c-8f8d-fa886b2fc597">(0018,4000)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cde84e69-3a73-416d-8fc8-5a7401d8ccba">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ae3f824e-e3ea-4d9b-9373-3fd0148a6231">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cedec952-f5e2-4d6f-bb95-0b5661517ff7">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ae2fecfe-07c9-41fd-896f-db2dcd9e810f">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_01a6242c-172a-4ee0-8518-74652e0509cd">Acquisition Context Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_64e6c4f5-0e64-4671-8bf2-34ab4049954d">(0040,0556)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_83f5ace7-7ce8-428f-9570-4cb70b1b2f83">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_56a0c872-6bbb-4ca1-a110-738db75fb1c4">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_604521e1-c1d5-4331-ade0-ae21ca43e0ba">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_49982a17-9853-45cc-8cc1-86d9b9724e63">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_045bc7be-238b-4ba2-b271-d80e1a8c9748">Acquisition Context Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_30794a69-1c9f-4803-983a-76e3201d5556">(0040,0555)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_679ed018-7598-4e71-89d8-13330257e27f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e4aecdf5-5073-4584-ab3c-6cbdb2345393">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_defe6a5d-af72-4b40-8b08-2c88470ca485">X/Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aca1ed20-6ad4-4a2b-b071-416eb914aedf">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2db199e6-7fa1-42e6-9d9f-6f8980d11f73">Acquisition Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e218434c-d0b0-40b8-8bc6-9cca2c6aa5e7">(0008,0022)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fc5da6d7-9882-4475-addc-7f79876e593b">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_70e65cb6-ba19-4cef-8664-12520932c5fd">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bf6247fe-b054-4bda-bba9-7cb0247ea531">X/Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_54f44ef4-7443-44e3-8c19-0ae173ae0aa8">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e0c3d40e-4603-4a37-8f65-fef89cf58fe7">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0794a3e-df29-480d-b536-7f75fe1cb37c">Acquisition DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_61d31ed8-d59f-4c95-bc78-1594a0670275">(0008,002A)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8ab00502-6192-403c-b68d-c84abf87de0e">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c3e10274-64dd-48e5-b94e-5bd78d3adb47">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5eaf1c7b-52fe-4f39-b6ee-6bfba802dea0">X/Z/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7363f436-5e67-478a-82b9-9cc69b9e4782">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_26d2d7c6-a725-4140-9922-0dc43d5abeab">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc02fed6-18e1-41f5-86ea-09f8882555ea">Acquisition Device Processing Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_27d50cbf-3196-4cb8-b885-e9334537283a">(0018,1400)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_134665e7-b01e-4671-b9a9-ff7c10bd2a05">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_653ff06e-2425-4be8-baa9-283f52b21b83">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5524397a-900a-4f87-83c5-444a3829c7dd">X/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b486fdf5-7b53-4d46-8df2-d15731950592">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8498afbf-e026-4116-97bd-85689b0fc096">Acquisition Field of View Label</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9782965a-b755-482d-a2da-b48dd30581de">(0018,11BB)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_58af51c0-f6bf-4c30-99c0-f1cbdd646802">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_027c1d3c-5f13-4614-b5c3-52714013419f">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69d69aa5-f5a4-471d-994b-518748c9de5c">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4c25bcae-b6d4-4c13-9e0f-92d277abe349">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_12701aef-cdba-4241-a6c9-40abcc1e34de">Acquisition Protocol Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_58ba9227-4cee-4af9-b76a-4d9cba3cd38a">(0018,9424)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1456fe80-e588-461d-8fc4-ff921cab6c98">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_54be0091-2ce9-4b9b-abd0-b97a27c8b892">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_45ab57e6-3b4f-4112-a8d7-99a1610e86a7">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fd5ae7a2-a16f-4586-ba39-369cb313deb4">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2219f99e-fff0-45ce-b873-c7d6292fbfa5">Acquisition Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_30b88540-304e-4386-8ad0-feddbf892228">(0008,0032)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_455c8e3b-0d15-4048-b69a-68ac955f6d0d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_46ef8c7b-d438-420e-a01a-8b0723340ebe">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_88fab02c-b62e-488f-91fb-38d17db2554c">X/Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_809f76a2-2556-4b00-8bf6-1eada79a7f8f">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d8d9759c-a912-4e7b-a859-8df393b6494f">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb128a27-8bdb-4821-a191-53078e9516f7">Acquisition UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_db09835e-63b4-4abb-b40c-693b0b614cc8">(0008,0017)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f7484677-bf31-4c3b-86a0-7ba05cd73e14">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_475eb8e3-7a5a-4f29-bd60-2611c8f4f458">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7243029d-e164-4b00-b53e-4f275ed6fed8">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c1979925-e928-4e96-b5ab-2bf5fb8472d0">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f74b027-3001-42cb-88eb-e306a360e06c">Actual Human Performers Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0a528302-de6f-4b52-84d3-13b0b8615959">(0040,4035)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7bd19d0e-9166-4f87-866c-04db084acb74">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0a9227b1-28d6-470f-8137-6be6b84f6960">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_60bdde99-7d6b-44e0-a427-72ccc2872d5f">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86016f2a-4bea-46df-a86c-f321112e96d8">Additional Patient History</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_53282cd6-9b86-4153-be53-33af3eb6b398">(0010,21B0)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a5a68f7d-2f23-48ba-8af1-ffab88d072a3">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_16c4bf82-9376-4d33-a66f-2225adc1f6ab">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e676949e-4cf9-4518-a83f-acce5af41412">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_080e032d-4f12-4cc1-9a8f-f741da747d29">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ccad0090-87e6-48d8-9950-6b229fe1f76b">Address (Trial)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_446c6237-5d00-491d-8f42-f880eb897f14">(0040,A353)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1bff7b26-9e18-42fe-b7f7-34c206466d86">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1746e820-0e5e-489a-a6e4-62f5cac8a551">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3737828a-f5cb-4b77-94f0-c0e574a1af77">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5b8f1d9-e5b1-4623-9096-e402b3a754d8">Admission ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_990dd508-0031-444c-89f8-4f8cb9a2bcaa">(0038,0010)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5c878377-5741-427f-ab22-fdb0801bc3d0">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c48675da-9352-4151-a856-b4d263f82f4a">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_93c57e36-a55b-4dae-a821-8a1df70a6d86">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de297ffe-d2f4-4d18-a89e-2e0845267710">Admitting Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3ab5f326-0a2a-4dc8-853b-39f144869b8b">(0038,0020)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6324b662-e533-4313-ad94-2101f984a9bc">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2bf3f7b1-f25d-4dc1-951c-09a8cad17d84">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1c205c37-3805-42fc-97a8-92bead742194">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d1e2764a-2821-46dd-a891-7aca52ddbc86">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ce9f619-d990-42d5-b372-cd0eaac8c479">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_15c97b8c-2113-4cff-b311-fd3295a88867">Admitting Diagnoses Code Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c9d47dd-6081-448e-9bcd-b283febf4351">(0008,1084)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ea1309e5-e199-44c8-a82a-e3b8feb6e6f3">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9ccfebb5-60d4-4f35-8387-df8eb1cf0450">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_81e95ca4-43e3-4f33-801b-994bbe043ea1">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_79de8700-4bbd-4c6d-aade-957b860c5c7b">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_23bffb9d-ad86-43ab-b443-72d75537f2ce">Admitting Diagnoses Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8052ea0d-3819-4867-9f82-4d57fd859603">(0008,1080)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_040a7b67-3198-4772-ba18-f66d11bc92b6">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0c7a4caa-2681-4b42-8106-14641425fb69">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73e1882f-1173-42b7-8642-ac514329cdbf">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1f2e117d-d68f-48de-8fac-2232760c7f9d">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_600eee4d-15eb-44b0-b5ec-3a900805235f">Admitting Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a6361954-ec39-45e3-8837-48e120ed01e5">(0038,0021)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_91ea360f-ea89-459e-87a7-b71412ee34ba">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c25505e3-5551-47e3-87c0-c5077f9f105f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d6b7bffe-a783-45f5-83ee-6fd12dd6a01a">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aaa83cd5-a421-48ee-ab58-0bcdd7a28451">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a0ebb56a-4906-4100-8e20-72ee09e30238">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b9fc8c4-5c98-48e6-ae4c-54aadcae08b2">Affected SOP Instance UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c091f8f-9251-4b83-b69b-16840c97d391">(0000,1000)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ac434810-5679-4e4e-bd9e-f0d52d19d153">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_68a51028-b61e-4ebf-87d9-91de2b7c89ff">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2db94b0c-479b-496e-8d9f-8e6756f7991f">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f7ca3a25-72f2-464c-b97d-e29146e38f05">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0dbce715-91bc-4887-9fc0-cc6712471694">Allergies</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_13a83e1a-e90b-40a2-a1ed-bc7d2377823e">(0010,2110)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aa989aa2-b06f-4618-ab2c-9cdc6c45d99a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e258c369-aa92-4031-b578-d5f6d472ba1a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_480b6024-600e-41ca-bb7c-13147bbe949f">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_692d1e90-82fe-44ed-a9a7-5f4912d521ec">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2182c5c0-b6b2-4a95-a45e-07c96538a693">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c23efe7-2cf8-44cb-b76c-fb3fd36198f0">Annotation DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_502f947b-13a6-49ca-8b4a-062bf908a0b5">(0040,B034)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f58a21b8-d06c-4c86-ac39-36980bcb137e">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_86031ba3-b058-4593-9257-d35368534ecc">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_13537d22-e0db-4048-8986-30af68388637">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0135ab41-127d-4c72-a660-3e9c8c1158e3">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_23197d41-3c4c-4c88-a619-491148a505db">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_537d9ba5-e0f4-4eca-b3af-c91bf7f33434">Annotation Group Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_41b6e1cf-44bd-44da-a092-0182371f8462">(006A,0006)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c5285fb3-e4b3-4e94-8696-56bc65d74642">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8e05b66c-2d93-4135-84d8-2c666d11e4a9">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a590a930-d5fa-4614-a6e2-484415f9ca6c">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_528c4307-f692-488a-a449-bf578da7c892">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99903a9f-8afd-408a-bf6d-c1754170ee80">Annotation Group Label</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_239f958f-cb24-427b-8ef9-eb7c478bbd67">(006A,0005)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2ae700da-81ba-4acd-9ab1-ee7ba86eba08">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1c559b9a-6ce8-46be-a81a-9c7558b58b0d">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6a441b3b-c867-4bdf-b669-d2b64f7d61fe">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6b4f5f2d-eba0-4cf2-a8c0-e5155cf9cb8d">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd4a8e83-f915-4601-b648-911dcfb31807">Annotation Group UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_67e86d35-75e3-46a4-a03c-962288af81df">(006A,0003)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_319f4f81-5255-4a1a-bdb0-691db18098f3">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2339a0fb-0b9f-4e12-874c-83eebd9f4733">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_916a9c86-1eca-4127-ac6b-9f3b47435e9d">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_11782cc7-c447-4129-b3d5-795e71c045cc">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5d2d632-4128-4842-a87c-c9217c5e47c4">Approval Status DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5716f944-d619-4d66-8ea7-59b06bdaf949">(0044,0004)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cca11e48-98c5-49b2-a8bb-6a9128a87964">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f1189b6b-c197-4478-a427-1fd3efb2cf82">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_78acb2be-3ce0-4c0e-90b1-70dc8f5fa9fe">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b46a3f79-183a-4a92-82eb-96bc87b7ed20">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6dda1db4-d59b-4441-b0be-af1f6daf0765">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_47ee66e5-8eef-41f0-848b-71847f4710db">Arbitrary</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_767bf81c-a244-44df-9dfd-3551c447c951">(4000,0010)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_361442e2-f798-4b9a-b56e-e554edf6410b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b19be65c-33af-4a98-be8b-5609a5ea7e0a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_661ed98b-9d57-440b-b1f4-8c3e50a878fc">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b85eae9a-e1c8-4b73-bea2-4a3c58a8c57e">Assertion DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_26f3a50c-9b77-4126-9d6b-314409ece7f0">(0044,0104)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c5c76bf4-5c24-4142-9003-d1ba48f2ff81">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_46e2a394-d1f8-409f-88bf-3eca55d80035">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d1339ac5-f00d-4a64-865e-bc2df49540f4">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c1d4d93c-e921-4551-8925-e7fa4605520b">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_999e98ea-0c2e-4709-adb7-a5a6babe83b2">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6aacd8c8-62cf-4945-8fc7-2911be3c3d76">Assertion Expiration DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7a67b99-cf33-4022-8909-3b952fc1ea9a">(0044,0105)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1f0e83d2-df6d-4713-91b8-5d472017fcb6">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9e559ffa-75cc-46de-aa33-bbceeb42f022">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6dfe6dea-455d-4887-b3b2-b933662fd495">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_88ceb9b1-3938-4156-beca-ebc977b3ee70">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_66d22bc8-8bec-4ced-8c55-21ee1f7b6f3c">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3448c4d5-eb81-4072-af9b-8e588738933d">Attribute Modification DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_83adadd8-36db-44b1-8b12-5ecb44835efb">(0400,0562)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_445410d2-c455-4b90-9bbd-55058ea58e76">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0e59051f-5254-47e5-b885-7a13a5948bbd">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4be9342f-3a2f-4c59-939d-21e86fe720a9">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0e2f2d78-45c7-4b83-88b3-74d2b2eeaf5b">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b1d22da6-1ed9-4997-b715-92a3b49d7fd5">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d1ce81d-971c-40be-9a5c-f1f2bfaaacd8">Author Observer Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6727537e-2a22-4306-9c4c-e03c74bf21af">(0040,A078)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_33f447b8-b717-466a-be07-1bc954b7a1ee">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ad07fc9b-6db3-46c4-a139-d323516858f8">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5b78c27d-4153-429f-ae5e-ce63e967694e">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6292dd8d-42bf-4231-bf3f-d6d0449ab7c8">Barcode Value</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e54942de-2779-4f8d-a692-12723b6d1998">(2200,0005)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_58746c42-c056-486e-b72a-fbd875241353">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_da9876eb-3edd-4d2d-be6d-a5534069fc12">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8666bbc6-b5fb-47ed-9712-c44dd8d41c7e">X/Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6aa04620-6b0c-4562-ae54-824d66bddec3">Beam Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e142cbda-d59e-428d-8dbb-56bc7e54252f">(300A,00C3)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_42bbc9ee-3a23-4b6a-9376-0ecb93467bd2">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2aca4a39-f465-40de-bf71-8ca21ace509b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d437e095-00b0-46d5-b87d-c6180ef9eb46">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_56329fb5-452d-4347-8606-04cb7c3c0f52">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_12a85312-2e82-46b4-9d57-a8555c4cbe63">Beam Hold Transition DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d1b6fdd9-a211-45d8-86fa-8701d45ce275">(300C,0127)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dde14453-eb89-42af-b94b-e7fa3b0984f1">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e65e2986-7a56-4929-83ee-5bc3dbb38e36">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3adbf612-a13e-4418-aedd-4f24c00b8066">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8bb93a0e-ea78-4906-a316-7779f9bac319">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ed37137-c02f-482c-ba5f-e97b30eaab0f">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_abdeadd9-75c0-4e76-91d7-3d1a4a451e7f">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43e996de-424c-408c-b788-3c4dc831b397">Bolus Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_93dc9311-79dc-42da-8daf-c51d2681f529">(300A,00DD)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f2da0ba-204b-4a38-8bf1-a3491bde9968">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4cb8803a-59c4-43df-8980-cde11a82c499">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b549f816-37cc-4e6c-a1cc-426d6e47381c">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_801564e9-853d-4bc4-a46f-ebd7ab80a14d">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1f23d70-1811-4fbc-a400-1ac469618897">Branch of Service</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7fc6beea-5722-49ce-b6a5-be1d595e5b3e">(0010,1081)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_55ca50b8-8d57-41ed-90db-fc860df24e94">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3bf5f594-8842-4601-a873-5ab6eb1b2bef">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_92e224ef-a432-4a5c-93fb-7f146dd4b041">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b8c22ea6-f524-4418-b93f-d31e07dc1f74">Calibration Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69c4211e-474e-42fd-9c5d-98906f9751a1">(0014,407E)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9995d0bf-14b9-4dfa-9209-93e2f3ef91f6">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4622bcb3-f625-48c0-9e6d-932f8ca5eaae">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_57f44864-7dff-4d98-a8dc-b04f001e7b7e">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_45b85cb8-709b-4591-9e2b-135cdef18db7">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_63b39f84-acd1-4e7f-875b-ce7f24ce0d6b">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f71610dc-688e-49f3-bba3-953b0fbd14d4">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_98f9edd0-ed9f-47bf-add7-0b481374c9d5">Calibration DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_535dc704-5cc9-43ab-95a4-48ca96d35e27">(0018,1203)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d404140f-bd14-4658-867b-2332862a5a2d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9cd45816-657d-49ce-8da7-2fc2fbcd53cc">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aa0de7d8-3a0b-45a5-b54e-2816f9004338">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_60bf0e94-63a1-494d-94d7-f04db18ed4ef">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_059cddd0-d6f1-4b1f-8aef-8d7c7049c4d6">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4424ef46-c307-4cc2-847b-59900d9188d3">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7f5d14f-f69c-4705-84c7-20694c43af52">Calibration Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_49830d93-5a21-4b58-9fc6-02b8295ccde1">(0014,407C)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d04db442-44a6-4371-b1d2-173042edd893">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7f08ed0c-c652-4728-8b43-638055f312b6">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a38e2fe6-1913-4f75-9aca-71468b22467a">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c0526ddc-5d09-46b6-8f74-aacdb041d837">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5e15fd5d-fce4-49d6-b3f3-88a6b019d6ad">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dd9b231f-0c37-4554-b6d8-5ca32e2c6731">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7fc566b-ea6b-4ab6-a645-756a620933b3">Camera Owner Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3c6e67fe-d7bb-4685-98d8-a78cc49538d0">(0016,004D)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5e97b821-d1e5-47f2-bec4-4b0abe44a59a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fc11b997-3b65-470a-a622-6dd7474c4bd7">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b98e996b-749d-4a5c-9c17-1353f7798502">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc871290-b5df-4b6c-aa79-bfc369aea4e0">Cassette ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_001a25bc-7036-486f-ac54-5aa76244dae2">(0018,1007)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_24c3fe6e-a04c-4a2f-8fab-7dcbe32650cb">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_54f8c2fe-e090-486e-b5f5-7267ddab1232">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_29af366e-f453-4f6d-b14c-51af38d5b5ee">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3564fd29-7a9f-46c0-9178-bbc624ed9330">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1557345-430c-420d-aab7-6b4b60f8c534">Certificate of Signer</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_be8222bd-b386-436f-b52c-370b5e26d707">(0400,0115)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d735b437-88e0-4b20-bbcc-8d6d2ee36489">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_07b96800-1038-46f8-9e99-c6544235d4b3">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8980e23a-1b94-4d5f-a43b-0a0ad269a392">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ccb45e2-a663-44dd-a338-3652ac0da3b0">Certified Timestamp</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_91e8705f-56c5-4ce4-a873-8ce7662eb677">(0400,0310)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3ac3575e-4b19-4785-aec1-2d22a930dfbf">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_efd97401-df13-4228-ae0f-3c5baaad1621">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4f3ae536-f49c-4d1a-b250-3c95de95b91d">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f44b8e07-1c95-4168-9849-aa4dd9c12fd4">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2eb72d2a-c85a-4bae-bf70-acb4f3b47929">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_baa39e27-2512-4326-a7f7-ad7d8c8eeb39">Channel Derivation Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_01f3473a-9a1a-4480-916d-f5d1a49f2a07">(003A,020C)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_88097392-14eb-489f-b578-747ed9763898">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0ae1da6e-ec1c-40bf-a851-976530d97ebd">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f0e0d1e1-77f9-4579-a943-d362ece1a26c">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_03792fb6-1207-44bd-8fd5-eebd135b075f">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6aba7831-9e16-436b-988e-6a7706990acb">Channel Label</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6b473e99-a0e3-4c57-a733-ef94b203d60d">(003A,0203)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1aa4b959-4db5-4926-a82c-d0649efd9e26">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_316667c3-4251-41aa-b49e-6a356313281a">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e9db6788-dabd-4cd7-b018-dd00988d46a5">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_36b726cb-e362-4e31-959b-85dc03a6249c">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8681bd6-fe5b-4e99-beb3-bf25ccfa57d9">Clinical Trial Coordinating Center Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3556e997-9655-4f29-9ea6-7a23c9c1898b">(0012,0060)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7cbfad29-b777-44be-9857-ed5c8900bebd">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d15083d2-e437-4064-a298-bfc3c19fe3d5">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6132fcab-34d5-4848-b170-5ff4a9573498">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_74d9b2f7-0089-4cb6-bde3-7e640bb9474c">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b18fd2e-1996-4410-9d98-e33f63a6c9f0">Clinical Trial Protocol Ethics Committee Approval Number</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b87e58e3-b626-49b6-b669-2f1cbd89e222">(0012,0082)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1fb2a442-e8e4-4980-9755-41718f38d1d0">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0415be53-b305-4503-9379-d9a20088b8f6">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b0b6f3d9-1e52-40f8-be8e-56e8d68c46fe">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca2932a6-2bec-4b69-86a3-b727706cc420">Clinical Trial Protocol Ethics Committee Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a0e2d7a0-ce35-4f30-9758-c6a6da42bd66">(0012,0081)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8b3e11ed-ab8f-4a7c-a178-2696c000f3df">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e6b89838-f91c-491c-aa7a-459a4364140e">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_12d1ab00-4cca-4561-be46-8d8b05a79ed5">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_463784ab-a5f2-441b-bf69-a0a7d02a40e4">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be04b8e9-040f-4046-8418-29cd323f6cfa">Clinical Trial Protocol ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fed12231-cf97-4804-a878-9d4e6bd1eaca">(0012,0020)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bd3fe0ec-3951-446b-890d-7e1cc8526c16">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ca32847a-520c-4135-ad8a-66295f5f07e8">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1612bf78-6950-49b4-b71f-7e433908f944">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf26dfb8-9a3a-4dcf-8e15-f05e75627553">Clinical Trial Protocol Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f8cd9392-7d47-42ed-9066-7db3a3e3a3e6">(0012,0021)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0d726e67-5697-4360-aee5-7efb14aba4a0">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2c33a5a5-1565-4568-a6c7-e7a82621b341">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0d5de0d7-e5c2-48b4-85be-b786b6338b2c">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fdbd562d-8b73-4854-8cfc-5874f9425e0a">Clinical Trial Series Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_888c80f8-c739-4cc5-9a2c-6315ae3eec57">(0012,0072)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_86e3dcc3-aa83-4409-8a75-de9b6bdef2dc">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_07ae8c46-ca7e-4d9e-aa7a-b70629f8f011">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_570569a5-077a-418a-adae-59139915038f">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0dccfed0-1e80-48ad-a19a-b336b9c0182b">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65b58402-ba01-4eb3-bf4f-c458c03245b1">Clinical Trial Series ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_16174f00-62bb-4464-a9ca-0491896bb18a">(0012,0071)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_248bd5fe-357c-4ad4-8352-91a152e23e51">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b218c676-1324-4c2b-bffc-512f9f32344a">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8083ca92-0303-4798-a91b-217fcdb393ea">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8db6f6f3-59a2-44fe-9f23-bb9a0236f2ae">Clinical Trial Site ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_af22136b-9b8d-48bb-8dc3-416c7a4c51b4">(0012,0030)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a53a7555-bbd9-4675-8528-34e444c060f2">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7a11fef8-dc4e-486c-a7dc-fb695363d646">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4c0a120a-e67f-4750-ba17-7a761b07a3b8">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a9128551-fb61-41f5-a295-3d93e903bca9">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4a7a4b8-13d6-4f20-b92e-e53c0f03a882">Clinical Trial Site Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f500c9bb-6e32-4dc7-8cbf-338ecc1bbce7">(0012,0031)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1886508f-fb63-4702-aeff-8aa38f6d9915">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6cc51edf-3c0e-4f17-8288-034875b51245">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e08eb231-b0e6-470d-8584-66a435ede6b2">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9a1151f9-aa18-43f6-9221-45bb18c0e575">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30ddb15c-530b-43a5-971e-ded48eb5c3a9">Clinical Trial Sponsor Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_63ae620a-7c69-4364-bbea-15507746f356">(0012,0010)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_20f91483-a684-42a6-87b6-9e33abe8f473">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b053575-336b-4a95-9d03-597120def4e5">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_37be3852-a074-4bd9-becd-89b98180c183">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aca85ad6-6fa4-4453-b036-7b9453001cde">Clinical Trial Subject ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b3aa1169-7170-43a0-9baa-fa98a3b35b28">(0012,0040)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c8dab3d2-ae61-4f73-bc78-3c8c57820bd9">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_14e0e13e-079d-47c3-8085-b40f1472a8f5">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_84ddef59-d0b4-4171-87f1-14ff83deecc0">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_64b95406-36b5-41c4-a28d-d5565ae80443">Clinical Trial Subject Reading ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9d6e2dc5-14af-4649-8dfa-7beefd8660b4">(0012,0042)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f5292df6-4c3a-4b4e-b63f-ab84fcf244d1">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2a15081e-bb79-48fe-9f8f-a057f5b73543">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1a90f5e6-2ef3-4d00-acd7-2cb0f51ae8da">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81fb1084-0864-44a5-b970-0a9450460415">Clinical Trial Time Point Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aaf44e10-6bad-417f-ba0f-8d582ddf48d1">(0012,0051)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_63f3f5da-7562-47d4-a4a9-7f6fed48e5a7">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c178bda0-af6e-4c1b-a94e-e6d0d5e9be6d">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_efa90eb8-503a-48ff-add5-4d7aa66f40d2">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_71731c15-ac2e-4e17-9ab2-77e50ecd3e41">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cfd9459b-d35d-411d-8ca0-e682479e66af">Clinical Trial Time Point ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_408b793e-d78f-4543-8929-d7e797cccd91">(0012,0050)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ac4764b2-0d97-495f-9c1a-258d8582a959">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a7ec4f6c-9842-4506-a2a8-fa18d79abc35">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eed68db6-7602-4a9f-921c-6f85997d7ce6">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4137b5f0-e939-4350-94e6-07e041a3cced">Comments on Radiation Dose</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_29e8bd0e-682b-4502-97fc-53121e7a0272">(0040,0310)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5bca0ccd-b01c-4a9f-8c08-8d027f6ae2f3">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f24a786-d7a2-403e-922a-69041435aa4c">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8d7133ec-47b0-476e-8f62-9a8ceaf14251">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6d1083e9-b46c-4800-89ef-d9f75f64e792">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0bcc96fe-d804-4061-b8a3-6a0b0aafeab1">Comments on the Performed Procedure Step</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_131a4b0b-827a-4224-b39b-b0e662f75702">(0040,0280)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d81cbbe8-c311-4069-9bf2-87797e429141">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1a90dbbf-b38d-4770-b8e6-c78ff5736874">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_051b54f0-44d6-4af7-b3bc-33ca68ff01fd">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5038109a-64a3-4f24-aee2-ab324e702038">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc4a30d9-1516-4213-877b-366fdc63f766">Compensator Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d45a1ed-c8df-4b55-b271-31538e6e542e">(300A,02EB)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0ea60826-045b-498c-923b-faef6f0d9c02">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c1ae58dc-2695-40c0-9a34-3015b0c6038c">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a6c74550-a65f-4414-9185-185c8da826cc">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0fa4b674-a2a7-4061-b42a-c7745a2675de">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83bb8109-78d4-4082-b75a-9b3623cc6d21">Concatenation UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_79a69c56-4bd2-4433-97b6-983d43e7cb71">(0020,9161)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7c39068f-8c3e-4f99-9f8c-0213ec823750">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e5641f36-5216-4f54-b172-36d598d9958b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3e619023-0c43-4399-bba0-3c23c938f412">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_67de321b-bf70-4494-8b5f-327791df230d">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef565faf-3b96-4615-8a22-bc867b7323e9">Conceptual Volume Combination Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2fa7289f-bc03-480f-b83d-bd90e3f3dc36">(3010,000F)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ba9c8e3-208f-464d-b1e0-fbb1addf3482">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d0d869c5-5d7e-405b-a17b-7c17f9191c0a">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_07723a2a-ea32-438b-b187-150d35d940cd">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_72c53627-1a1d-4271-b415-1dff39034b6e">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c9de0d11-4e81-45de-a5d0-7e8843df215b">Conceptual Volume Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a92b5c6d-8add-4a66-8074-c7c1cf262e4d">(3010,0017)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ef704d9d-dbf6-4f61-943c-f65718a6f9ef">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e574986c-205a-44f9-8b91-d4268273fec2">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_56e88491-17e3-484c-9759-b334fe98a07d">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b48d7383-2e58-4691-a738-067cd1b4ba7d">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63e4ab92-1694-4c53-9185-e8c1ee5f9211">Conceptual Volume UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3861fe03-ed19-4804-b123-3aeadb2c9903">(3010,0006)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fa27d50d-073f-44e8-a3bb-ec6275d2a38f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_02e14ee8-eec2-4ca1-b00c-0bdd32089eba">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85ea1ad1-bce2-4d00-b431-492820718f81">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a671accc-ba3b-4282-a2ec-617e364f2f8e">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d3a688d-991c-4542-86c5-2358fc5b2125">Confidentiality Constraint on Patient Data Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5ca0fbb3-5424-4af2-beaa-7577c69086ee">(0040,3001)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9cd8e4c9-f30a-4077-a17a-ee675757875d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6deff8ee-d2c9-4cf6-8a9a-4e65210d6257">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e1642b97-3ccd-434d-9dcd-39a42122a359">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05b0adee-3aaf-4988-97a2-71e3bf720f63">Constituent Conceptual Volume UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f9e9f465-98a8-4ff5-bb32-37700452d75a">(3010,0013)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_543ef70d-8f83-4a57-a61a-d4a4443ffdbd">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7ceb4110-a090-422f-a4b3-f37eec3e4ad9">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_29c01376-4563-4361-9942-8e8ea960f3f6">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_29a061f0-05bc-40db-b764-92003ef38c4d">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da9ac021-73a2-4c01-8a89-b50deccaee51">Consulting Physician's Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bf682450-a8d2-459c-8877-7b33b20971f4">(0008,009C)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_803b6864-238e-4aca-931c-abed3ce7a7d3">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_483d2939-6347-41c1-b45e-6baf560e98be">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c025dfd9-8855-4397-a9d4-ae8a4c92b401">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_66df3c57-9aef-45c0-a6b6-003897abbe01">Consulting Physician Identification Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6bfae49b-a1d0-4f34-8ed1-4f44d9f19390">(0008,009D)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9a45d3cb-66c4-4518-b739-8de530c6342c">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_66236d6a-2a35-4c60-8e1d-d4f7507c10d8">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7bc9fbbb-7adc-4757-ac3d-b63837ebcc5b">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2b332e63-772b-4922-8e33-e216052741d4">Container Component ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_70ad9f0e-648e-4fcc-a303-492e75055747">(0050,001B)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4c9a1b97-bd23-4031-8f4c-e8eaf4181fcc">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e3d807ad-23d3-453f-8d58-6c5d50bb77bd">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f519308-49a5-4ee4-84e6-fb68a0b0c945">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43e550fa-9ccc-47f7-a6b3-784a81970468">Container Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6818658e-d1ca-4068-b84c-cb908da918cb">(0040,051A)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_968bbee0-4a65-4173-a6d0-e5bdfe95b9ad">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_acb07f71-3b0d-4800-b749-600199876cd6">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_397d5ef1-bcba-42c0-8b0e-92b7175cb6ed">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_31f82419-5d4f-4352-9614-7a3f7611e4c7">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43cf990c-f0eb-458c-a790-c2ecbf5e933b">Container Identifier</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3b0a8790-48f0-4ba5-829b-a895019158a9">(0040,0512)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3df09c6e-e365-4898-9244-ab40c77f2b1e">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c8ad902e-f950-4dd9-8850-6b86062ec225">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_46e5ccc6-425e-4449-af9e-e8af258347ea">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_640d4e2b-9c2c-42d2-a281-d2f5f042430c">Content Creator's Identification Code Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c41d3862-5f0a-4cb6-9828-346ce65f03f5">(0070,0086)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fd92a97d-3dd2-4da1-b145-59caf6066778">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f82a7f3a-3333-4e33-b6d1-0d0aaa085899">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6633eb1e-cf0d-4eca-90f2-674a272f927e">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a1240f50-99ae-4b92-8e28-c426de090394">Content Creator's Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0b831c19-b116-47a2-8b3c-fd8669ec4517">(0070,0084)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e5fd7233-d130-49c7-bbf4-6a81156735e4">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_26118628-fddb-488b-aa04-243ec7c8b7af">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6d9c5de0-ed5d-4553-8ae4-5caf156a2fd8">Z/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b89db72-cafc-4504-9718-1527a11ec08b">Content Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7d2d87cb-e4b1-4d95-b9f7-23a92b657198">(0008,0023)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_be24737e-b681-4af3-baa6-1879f5591de4">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3e9af571-0e00-4f62-800d-f93873475e75">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0260db49-d1a0-4aec-a92f-b8fe115dcf9f">Z/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_19116ac5-0536-4428-ace8-bd457fd8bd2c">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ea4d0175-79bc-430e-8390-fd125df95a6a">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88bd47d6-b0f9-47a8-b283-1256423c7f8d">Content Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_02afaf47-684c-4c02-80d7-3e370a14fcd7">(0040,A730)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c3b8c358-ffbb-4584-93be-b872434a0eb3">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dc202d59-622e-4e13-9ec8-1c962edc95f3">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_743e79c5-dbcf-4b6b-a528-5bc6fd4b74dd">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8710a52b-bf5f-4c9f-bd47-05243ad9659f">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b625510-2219-4166-b1f3-2e942d4fa967">Content Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d39bcc6-acdb-48c5-a2bd-d9ac1a807111">(0008,0033)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0899fbf7-7805-4370-a99d-5e4de7667109">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4ba81f3c-1efa-4789-bd6f-e9fc79e909cd">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4980bf02-7f85-4e5a-ad0a-88fd4db7ecc4">Z/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fe1173dd-7c42-4880-8521-4d9db0e1553d">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_280a315f-8aff-4e5b-baa0-0ace588869e9">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b9327496-4851-41d7-ad9f-d3811c45170b">Context Group Local Version</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c66524a-cbd7-4e7b-85b4-a8ca102d17fe">(0008,0107)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1226e63b-f0d9-4e6d-8556-233112a5625b">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6b32dae6-9ee9-4e7b-813b-9d7ec648ad73">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9ca5784a-0d55-4e8b-8c3e-6f1a94b93597">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c208810d-01c1-4b48-baee-04de56136fde">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_888049fb-085d-49e1-a3f5-4a2d048d75fd">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de38f207-586c-4fd3-bcc9-8a75bc25d6ae">Context Group Version</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_01e7ba8a-2812-4714-b20f-66c4c31d750c">(0008,0106)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1a09854f-adf0-4e33-bf0c-61201ea01898">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_12eb3cd1-f884-4a34-9109-2df93bcbba5a">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_05a7fd3c-c779-4ff3-a4a3-9fc5f6370b6e">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dfd6bb06-8c06-4521-be0d-f787936bcc1f">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_52df506c-14fe-4b95-be86-7cde1fbd113a">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9368954-d32e-4144-bcbe-7c9e6c71b1b0">Contrast/Bolus Agent</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dba12593-6397-4199-9225-ab3609f90534">(0018,0010)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3a2172e7-d6bd-4904-8140-2a4aa6e01878">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cd87b50d-670b-467f-ad8a-4294c22a2567">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d08f4987-5d15-45e1-828d-3086ddcda6c7">Z/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d66b9211-26fe-41a7-9066-8e17203ff020">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f0a7f85-4421-4071-816e-a959d13e5275">Contrast/Bolus Start Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7b914a54-0d68-4079-a77d-2b075b4951ea">(0018,1042)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f494a87c-b26d-4699-afc6-80e8d20a4112">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_635113c2-6877-4fe8-bb74-e39c0158d6f6">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7c1c8278-dc0e-4461-bcfd-3f635a949fcd">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d98f5eb9-730a-494e-b15a-6cb9dd39f689">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dd1436e4-a52d-48cc-99aa-b5bc1be685b2">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a917496c-9beb-4e84-93a0-40f5f029159a">Contrast/Bolus Stop Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0114d591-f240-490e-aa22-d695e1ed5e7c">(0018,1043)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7fd1922f-491f-4c79-a6c4-f077f5998bf9">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1d40b827-28aa-4335-8b01-e0f8e460b1d0">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2a49fa14-259b-411c-b70c-f81a52831ddb">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_44154dfe-1679-42f9-a33f-127396deb3da">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_35d29166-08b8-4707-a92b-f872450649d8">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d42ba07-562f-4a32-8546-4fb54267831c">Contribution DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c943da0-e306-459b-b411-447441d9e833">(0018,A002)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f042c64a-3a74-4ad4-bfac-76008bd90498">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d6411502-5632-4203-aa95-f69174ed9edc">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_281bdfef-f194-4369-8646-8e6bc7e0e165">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_31e3a612-68b2-48e9-bfa4-de4641dd6ddf">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5aa6b346-bf70-4259-a6a1-d44991eee7b4">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f670858-6229-4d99-9d49-85d2ca3782fa">Contribution Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf3e1d17-d5af-481c-8002-b3b0af6701e2">(0018,A003)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_59dba7c9-682f-49e7-96b5-f8538fbc6659">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_62ba0304-11f8-45aa-8779-c595a7623afe">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_11f5c93f-1126-4b90-ad07-7758fa6e8e4c">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c7cc7f07-c0f5-43b1-b799-f91193940235">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cabcafc0-3520-49f3-9c2d-70a22ffef4dc">Country of Residence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7bfb70c2-5eff-4539-a882-e425e3fd8e39">(0010,2150)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a675013-7e36-4f03-b09f-96f395ddc060">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ade5d318-0ea3-44ce-870b-2124e4dfb659">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d00fb5e-091b-4694-9309-8518607549dc">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5aa36fd6-3ca6-4c98-bfae-e72f0bba28a0">Creation Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bb48547a-e63a-46a7-a93d-8a0d4c3df3c8">(2100,0040)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b4928afa-3969-412c-8339-c3bbb4fc5e36">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_361d63da-d3fb-43b1-a608-890fc3b1e5c4">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bffe4d92-20a3-4412-b5cb-db13920da3e3">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1776fee2-e804-4124-acda-4bf0b67fef06">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_43b771dd-b326-4607-a4cb-fdfce41e2dfe">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_814126e3-8b81-4390-8b50-2b3f3e4c50a2">Creation Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2d7d915a-07e8-4810-9931-d5fe3fbecc32">(2100,0050)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fc8c2a09-6d46-466e-9199-57ce1d34a41f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3882d364-5cec-4299-b4f7-8fec5f7fd699">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3f57f217-0caa-4ee1-9756-762ab5dec9fc">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3125b203-5628-4ac3-8180-3de9c10d52d4">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_86b3b960-4ac3-43f9-81be-2a2eaca2a351">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8509b85f-e55f-45cb-9307-8a19780ca8b4">Current Observer (Trial)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_faa80493-bb50-421f-91ca-1f7096ed36da">(0040,A307)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4ff030c1-2e21-419e-aa9f-2ed94ec545b7">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_08cb3b13-e597-4a8b-8ea8-3bfe1dfc6ab5">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1e130825-645d-42f3-a23e-0cdb19cb6af8">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d176a85a-6d93-4d67-94f2-40724f0cc9d8">Current Patient Location</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_197cd6ca-1e45-439f-ba91-8a7f00d40e90">(0038,0300)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_65df9dea-e16c-4377-9182-869618324f5a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f0cca20-5f5b-4ca0-9a21-e5446f692c87">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_886b36d9-aff8-48fa-a61d-b255178ead57">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1468f1b9-3fbe-4788-9432-200ee650eac3">Curve Data</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_54ed7329-2d98-414d-8f59-a1dc178dbd2e">(50xx,xxxx)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9629dd71-978c-4322-9358-8f5167f4fd3a">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_15a33ef7-d568-4e60-a642-330ce58f44b6">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3dbb57a4-07fc-4a05-886d-10b36fb30ce6">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c09be7b3-bcfe-43d0-ab30-7c1945518ae4">C</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_163fa71d-7751-4861-934e-ce6093c034c0">Curve Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8607a273-a70e-48a4-bcef-7e0ecafdea9a">(0008,0025)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_892cd05c-62c4-4ab5-9334-cf33c4fa429e">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0cfcf753-1080-4359-9863-6c3c993ac11e">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_11ff3606-47a2-4eda-b2db-84f4768f1835">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_34023bc8-3b36-4825-a1d3-dc5bd25c2260">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_705f7f57-b4f4-43ee-8b56-a80facc01ca0">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5a703ab-68e8-4a54-8770-ca70d6275523">Curve Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_017da96d-538c-4695-abb6-613ec0cd8ccd">(0008,0035)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0c63950f-fd6e-4f61-98b4-b2e385f70bec">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_62332cd9-a509-4ff5-85ca-e25dd0b6f0d8">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fbe35908-114e-4612-8abb-8114d55ad095">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_67b7a91d-79b1-4c1b-aabc-c9ecefcd2ae4">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0fd0b249-69f6-461e-9301-5f13f3525e10">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5e6d514-f18a-4f9d-a39b-8eba5d10b781">Custodial Organization Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2cadb8f9-aa8f-44d0-bfb2-4cb29ac2acd6">(0040,A07C)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_147450f3-3ae9-426a-9ff0-70f5787b608a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8e0c28a4-1b1f-49ea-bde0-9e5fff904716">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a374c3e4-3efa-464e-8b1c-566464aa658b">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ddf52ac3-063e-41f2-9f02-ea9b523fe92e">Data Set Trailing Padding</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9568aeaa-c5da-44ce-bf1d-7a9ad6198441">(FFFC,FFFC)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ead4ce2e-b5c3-4016-9074-a6a4d0a0a4f7">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d1b8c1f1-35e6-42f3-85ac-9d8b51b2be24">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2d9f8269-60e8-42bb-a609-97be8d63eba1">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6cc76aa5-a960-4d7b-94a7-747caa911fad">Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ab8d51ba-a9d5-4afa-a34a-17d9a02db817">(0040,A121)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_37560bd2-e123-4efe-8cea-4c9fba1b5315">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d824af4-c222-4a48-a10d-f2b18eb3ac3e">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_05ef69e6-2424-4882-91f0-48a1d4a234bb">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dff10032-4784-472a-81f0-2f3d212d6c04">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_980a8774-479a-49d1-99fb-97f952d2485a">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08392f30-3a8e-4547-89ec-d5d4cf045da2">Date of Document or Verbal Transaction (Trial)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_feac93c5-1600-4b34-bcc6-e2e030fcd893">(0040,A110)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_36ec46cb-399e-42c6-a85d-ab97a162b5c6">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f7056e51-3dfd-4ed4-9f56-ac9337f587ad">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9414665b-30cc-41e1-9157-12e15a6ee9cd">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_125a3701-5eee-4bb5-85ef-30720fc3897c">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cc7db35f-12de-4044-913b-31525b4d3e07">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4565ba7-52fe-4777-bfd8-1ec8edea956f">Date of Installation</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_433d79c4-cac9-4fa5-9bde-29aa83f24cf4">(0018,1205)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bfee989f-cedc-4866-a1ea-df2acb687414">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f73f31a8-fa08-4725-9015-a7b35943ab25">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_30f7100a-c8dd-4e03-8b67-649aa36c02d4">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_12383278-91a6-4b57-bf73-85ec46f06838">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ac8ef85a-d136-42c8-8389-8759213aeda1">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_caacaa92-c8c6-4203-a82b-320327f42572">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_40fb5121-ed59-4ca5-9766-f5008dffdb55">Date of Last Calibration</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b76f2114-a0b4-48b4-bffc-2cf0e2f69c6a">(0018,1200)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9339fd74-cbb5-453c-abfe-9b6ea0ba803d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_97b68c1f-f431-4f35-a6a6-644c78903973">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_53baeb3a-8313-4e0e-aad5-00c204c6a4dc">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_05ce393d-9192-45cf-a47d-454e47052ce8">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3923a1ba-2377-452c-9705-b1f9b76e239a">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_41cd4a6f-d258-4288-8840-17c91ed152a4">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_33cb9fb8-8c7e-4f2e-8b3f-e9f47d17a615">Date of Last Detector Calibration</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a85cd25f-414b-4eba-8afd-f9c3195b7227">(0018,700C)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cd7b0421-9fbc-4953-9cb5-b8fb6da5bfb6">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4378f82f-9213-4697-8512-c4e072b49328">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_594d03fa-054e-4f12-91ab-e7dc5e913198">X/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1e29c475-6036-43f1-b797-a685aef34d99">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ec0758f4-debc-4d3a-a126-85c36c3f03c5">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_81523a65-06cb-46ae-8d76-e9f10aa0bffb">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df720adb-4be1-4b6e-bd78-57f9294e11a7">Date of Manufacture</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_392a5a0d-e9c8-46cc-8b91-275bc12fc36a">(0018,1204)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_925b3b4f-83d6-48b3-8d98-a07d3fa0c20f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_00472b0e-878b-49e5-a97d-4de206f2390f">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_53aedee5-6f3b-4bbd-aa72-265fadf81480">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bb98ad2e-1afb-4499-8411-4b1c8b8047a8">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_24f87a97-d0bf-40a0-8636-08dcb8bae8d8">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_273e9057-b6d4-4bcc-9b12-a78d3f73d555">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_acdfa05e-f533-44b3-9d5a-f823bf857bea">Date of Secondary Capture</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0d697984-3698-49fe-bcf2-b00284a3323d">(0018,1012)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eb4dcaa9-124e-444e-a7e5-7a86c73c8d7f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3de753ed-9bfb-4a10-bb03-1714b86bb619">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6903eaae-9b2c-413f-8767-561a77b6deb6">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_744418f8-5452-4063-926b-505f0534ed5b">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a4359f26-4e04-438b-af35-d132a86445b5">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13d1a999-6b2c-43a7-8e37-0fc2c79c5734">DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_60c98d5f-edc2-46a2-91c8-75ddf08f4742">(0040,A120)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_950d8a40-6176-4dfc-851f-e5c73aab055e">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8ac97742-a5f5-4355-9bb9-d5401daf7f03">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_36720e82-399c-4e35-80d7-8a91484dabae">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3aa55fc4-c3ba-4e2e-84da-134d4158589a">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a051cfe0-b258-43d7-944e-223d95a0b713">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e234aa2-64dc-4b7d-8cac-f3eb04398a4e">DateTime of Last Calibration</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_56ef4b48-5285-4ba6-9506-3a09efe0402d">(0018,1202)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_841b47a7-ede6-4e0e-b133-54a8916a0b16">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_02fd65a8-9015-4ed2-8add-560ee3f0a01e">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_657fda6b-b758-481f-9f0f-f57027043304">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dd1aa176-129c-4c98-8d20-d7a00bb1e99d">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d1d5e721-7131-4249-a85b-216a49dccc71">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b22b65b8-7832-443a-bfd2-db483f72024f">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c2f8ea5-9848-48d0-88ef-5dbc3de398f7">Decay Correction DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c05a3e81-5a85-4661-8912-cda913ac0dfc">(0018,9701)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d81314f2-51b4-41d7-aeb4-f2bc744d789c">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5def8d9a-5bc5-491f-b882-faafad9ff8a3">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_99dd8876-03f0-41f2-a8ef-3f24bf6526af">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_addd4552-22b0-48da-92a8-54d1a7790a63">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1bf3119a-7dc3-4faf-83cb-a136e56ff2f8">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d79e6098-a660-4718-a479-d061ee91316e">Decomposition Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5ba0cd7c-e617-4d71-8671-5d61361dd19c">(0018,937F)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_46201c0a-ed58-46f7-a6ab-969d22c17ff8">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_57c78402-32a3-42fb-8812-175790d4fb83">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6e4a290a-a251-4035-9e5f-feaaad6582f8">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b4d36824-0385-4b37-81d2-b99820a40c56">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35644cf0-03ba-47af-b306-4b5d43a70a83">Derivation Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d536736e-7897-4699-be8c-e2eeb44f6cde">(0008,2111)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8b7a9b79-a854-42df-9ece-267d8ce94b67">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b341e5de-ca2a-472d-ac35-1ec8123a08d7">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_67177187-7660-43f2-9225-6e224c36aaec">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_786e16d3-972c-45f5-9389-3f467ea6777a">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1de665f-52e1-49b6-b1c1-6f1e251745e6">Destination AE</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_51a0e360-7309-4f76-b239-d6fdeb81e0f8">(2100,0140)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_82638151-249f-43af-b7d8-b92bdbe3a2a0">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e8093004-0cff-4692-bc21-a14bf0b15dba">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7830d20b-624a-423f-b66d-f7b25cb3bd5a">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7c10190-3e70-43a0-99ac-268ce53f1ba0">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d7d28ea-e865-46ee-9d26-caffd8fef6de">Detector ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_92e1bed6-0ad3-40a8-9567-01f5d0ddcf18">(0018,700A)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ec9875f3-f60b-4336-a5c3-40833d158c28">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_57cd74a0-1c08-4cb3-a277-600c9b545149">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dadadef7-f98e-477c-b539-1b74550837f6">X/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_16cab1b9-4d7c-4219-bdbb-61eaccd7331a">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5881e2a-62a6-4d6c-8b75-e0de9fb4f891">Device Alternate Identifier</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5d3bc77a-8f1b-4072-a194-2a3aaa39bf47">(3010,001B)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_19b26edb-7187-4461-8f7a-0e2dc3ac1be0">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ba1d36f1-d411-42ea-983c-812795c034b3">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a6f152a2-03c3-4b0b-b6ba-a323c8207e75">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59cbbd3d-eadc-45d2-96e1-84f6940d55f2">Device Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1bcc1d64-ecb7-42d4-9d0e-4574e9ceed36">(0050,0020)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f44b4a12-5d76-410b-b2fe-59e89104c785">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2b5c32cf-6ee2-4b45-ad9d-2e477314fa09">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6bffb001-a05f-4a01-a0f3-d325819eb788">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a290ca30-c265-47c1-8f51-7f0a48447b68">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ad8d7eb-0bde-4f01-8369-3a7cd7bf48e2">Device Label</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2aced51b-017a-46a4-8ded-bf41b2fd2a40">(3010,002D)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_53e1a3b6-3ccb-4c36-b586-493d8c621e9f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf35a9a6-a2bd-491f-8696-655302a42d1d">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9c01acbb-ea50-4bbc-9fd7-ae89d86169d0">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f8118f9-7573-4785-9c24-8157a81462b5">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff4e909e-b2ea-4cc2-adc5-6fd23268d1d9">Device Serial Number</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_59c171d5-7e7a-47f9-90d5-e136701d867d">(0018,1000)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_df0910f7-f2b8-4cfc-b488-6c674ebf511f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a17138ca-ff70-44d6-8ce5-a18094511f03">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1acb8726-68ae-4b7f-8787-0ef53bac9102">X/Z/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_498fa51e-aeea-4b47-86f9-5246a30d6013">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_44013946-d8ae-4a7e-aa41-08e5578086ca">Device Setting Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9996ea1c-0e1d-4b4e-922e-c3fa2431f4fb">(0016,004B)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_21dd9cb5-f835-48a6-b474-066b5399d2f9">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c8d80c89-9593-4a15-bec6-098490d94db6">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6b041717-975e-4e94-a31f-fb54244f20bf">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_34a1fb2c-de39-4fd0-ba98-1d6665a0bea4">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_476dea1c-549a-4487-a181-5640902b285f">Device UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_48adb2ab-ec21-4333-a7d3-4f85eb94194a">(0018,1002)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bbc6a8fb-1f6f-4be8-9adf-2b3f8b09ca5d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0f90c0bc-2506-441f-98a5-d443f84aa413">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_42727097-70f2-4517-b513-5687c45155dc">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_20626606-5c7f-4790-aee7-d86d1a658021">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7640238b-d372-42f3-9eb4-0a43aa3fd792">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_875dc597-949a-40fc-a6b7-fd6b86b96bd4">Digital Signature DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a7f5c39a-b5b4-48a1-a95e-7fb64fc93648">(0400,0105)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b24efa27-181b-4164-b8eb-928776db8cf7">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_186846a9-7ea1-4928-ae5a-2324c3ef049c">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c4dbc10c-968c-4828-9218-f91c9c2802e4">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5e462712-69af-4efd-83f6-b33faabac891">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8b8eec3b-365a-4df7-a327-fd5bc7918179">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b0cbfd6-3bd3-485a-903f-d896db68c3d3">Digital Signatures Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d70c3b59-ceea-4e81-9d71-f713057535ab">(FFFA,FFFA)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ca03cf71-377d-4b11-9753-bc6cffb290f1">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_93cab102-2b9e-4d89-afc1-19af108a3fae">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1a96ced3-a1e6-439e-b115-c171c49d360e">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11496fb7-9b22-4289-8bef-e5e541fcdff6">Digital Signature UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc5aeede-93dd-4a7a-999b-6efe2af5fcd9">(0400,0100)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2dc4c115-78e0-4ada-a028-2d8b5be4d4f7">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8eedab71-c7a1-4a39-b8c7-4e9105ef98bb">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ddd5a0d1-1d0b-434c-8062-4b4a15f78600">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9cfddc0-26e6-438e-881b-d775cc1f766b">Dimension Organization UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_053ba485-337b-414a-8f38-f8be1e68f94e">(0020,9164)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1c262061-df29-480c-8373-8a636b125161">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_710af217-9554-4b13-83d7-40d6d71c5aca">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1232a029-f34e-46a6-ae9a-4b266c3dca7e">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fdab0ab1-125a-4b43-bbf0-6fd1fcf1109c">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_976f2060-043a-467a-8403-a3354f1661ea">Discharge Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c32e7b73-3181-48f4-b0ec-60bfc1d1a8be">(0038,0030)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_361663a6-6912-4f89-8c71-d70fae146106">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7a68151c-b4e2-4740-acaa-72320e97614a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ee91cdbf-9ded-464e-842d-0e2dfe445b38">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1d4b985a-d377-4057-93da-b1c9bcd6fc5a">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_44a0e0df-9b03-40c2-a86f-25aaadecfa54">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ed78245-02a6-4c69-a7a8-4e66b7f846f1">Discharge Diagnosis Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_992259d1-c806-41ab-9e4e-9db17b843c5c">(0038,0040)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_32c38d37-9427-4688-b0f6-eb592f4067b4">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_72b476a7-f244-44d1-a126-46454277171b">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_08486ed3-6bba-41fe-8574-28805796eea1">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cdafd151-e437-4df3-8603-91cde65526d3">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_784b6bd2-c1d0-4353-8a4e-43de1fb83aab">Discharge Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_245f513f-d10f-4dfc-8626-bbf6c3008017">(0038,0032)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_360770d2-f30c-4ee0-9ad4-97db34eae72f">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ca6d634-3867-4b48-9d88-55e9dd84d8c0">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2b0f0399-b032-45c2-9f19-764d5a1d9ae7">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9aa8c78a-471d-4d1a-b8bc-e45682bbc4ca">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5e736da5-158f-4b97-a97d-85d5e84c7778">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_756fc792-0629-425e-9c5e-0805f1f9c2ac">Displacement Reference Label</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_09515a77-2690-4335-9f54-8302aa581326">(300A,079A)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_838882fc-89a4-4679-b204-9e7d9dc47854">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9ac88b1f-8c44-4b2b-ab11-ad01cfa5e513">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_50fe4fb0-3886-4c9f-a5c7-a8a824066ff3">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cfd5df0e-0c00-4caf-bdaf-a8dbb05f6762">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7804b1ff-d80c-4bde-99a7-a6da9bd7a9f8">Display URI</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_951a7707-2b7e-47a3-aa35-1719130d0646">(0040,E012)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4b29c704-2798-4bdb-ad92-975c9730ca42">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a4d2ea32-a38f-4d51-b718-1ad961d3d5a4">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b7e31c51-beef-478c-9a04-ec5bd73c9155">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba667ac1-71f5-4718-820b-43e51ef5a9d3">Distribution Address</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0b28701f-b7cf-45bb-a9cd-2c59890e823e">(4008,011A)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_79de51f2-143c-4103-8747-e536464c60c7">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b8eb748d-334a-4440-abdf-3857d1a2272b">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b88d1c07-580d-4eec-bd9e-d6b6325519b0">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d43c77f7-d13e-4963-a636-7122b8c25913">Distribution Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_80778931-945c-48dd-83cb-3b423dc16d04">(4008,0119)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4b7dad94-752b-4646-bdca-edaf01278d35">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c43920c6-bb10-44e9-918a-92f7cacac7d5">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a68d815d-091d-4dc5-9a17-836ffb307e78">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e105539d-375f-4801-b2e3-10aca4802b33">Dose Calculation Model Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_01b4adb4-42f6-4eb1-b406-ebad5c28c0bc">(3004,007F)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_743fb036-a449-4d17-a947-5b0bffddc7c9">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5ce86e55-5ea8-41b5-9b45-489c10efb4cb">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ec23988b-9080-4119-8406-85fa2e7851ad">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_02b8b80b-16a7-49a4-b257-6b64c4388406">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad1aff27-20e3-4a74-b348-c19b20d76130">Dose Reference Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7b242ad7-47db-443e-8376-9e69c50ec415">(300A,0016)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3361ce53-e6e0-48d3-a851-2e57f743e00c">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f04245f0-e1e1-4426-af7d-8ab55e6e76a3">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6b83b4fa-0ee9-4aa1-a249-69e93264d71e">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f290287d-e31b-4d53-9b05-0ed4f4cb7d19">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f53f2a51-7db1-4e55-9b34-44e5a7147e67">Dose Reference UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_49f0f028-0185-470c-94c3-fd950bb0f7e1">(300A,0013)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4f08b964-69d9-4508-967e-9370e901fa86">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f863ec71-bf0b-494c-89e1-f0a85b5fe52f">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eea8c015-0299-4a71-92ec-da72ed22c5f4">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_92b51411-85a0-40ae-b513-83ba2e7f47f4">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d80626c-e8cd-4c9b-84ef-ce82eb42eaaf">Dosimetric Objective UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5d603b63-703e-48c1-9fd3-1a2e1863bb13">(3010,006E)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fd23ac4a-0822-4ce6-a794-1eb2f1f63295">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b5727839-2ea8-4563-bba9-6ee5a4fbbe6c">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f485f63-cf00-4422-ad52-3a46c142728e">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d5397821-e8e9-4293-a6ce-49fb4368a0be">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7a5b43a4-1f66-4283-9687-f8e2375b2fa3">Effective DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_82629961-3a41-4f4b-8c26-e5473c297ef4">(0068,6226)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_affca807-2774-4e1c-aa5e-8feed4677316">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_70143055-159b-4371-9bac-bd0122fd6e78">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fdfee62a-3ada-477b-bf59-22d111b482d3">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e5a3b8a1-b0cd-406b-9c17-5f1b641680ce">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0e52d62d-077a-47f8-a310-0a6f0b11a060">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_039c564f-9e3e-4adf-ae92-e8b23c5a5811">Effective Start DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8345660b-de25-4dc8-bb12-c98cd02cda8e">(0040,A034)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_224d3bfe-27d9-4910-b536-b09c4422eb56">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a1f4ef0c-47de-411b-a5bf-4fc32b49f4c7">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2db7bbb8-c4d5-44f7-ad35-9ae7f4d80af6">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_26081fc3-7b17-49cb-9436-31792ebd5b69">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_10fa27e8-8312-400a-a6dc-1b7d89b3eec4">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e05da77-636f-403d-b72d-aee00c364a73">Effective Stop DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_586c6542-c378-4de1-b9e8-54feb625fd20">(0040,A035)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_409291ae-a20b-4d29-a13b-1e3bbf9783b8">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0952aec2-735b-44ba-b97e-fa5009ec378a">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1818ae09-2a2f-4d60-8211-f1acd8a90b8b">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7c3177f9-833a-416a-a333-d3904327824c">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7713d796-23b7-4f07-9871-7a5aa81506a7">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe324651-b5d5-4265-af5e-cca087f21bf6">Encapsulated Document</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_13495161-0226-4002-9123-4d4b1bf88d23">(0042,0011)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_237f0740-3bbf-49ba-83d6-b941fd8d0672">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ad31640e-1ec9-4231-9946-47faa7800882">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c8fc6c0a-063e-4b32-9197-e5c9046b4b7d">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f357336-b8c6-4bdb-b8b6-98d479e38662">End Acquisition DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_62cc5f7b-5aac-48e8-92b8-2aadbcee7b55">(0018,9517)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_27c9b8e7-511e-4ca4-92c4-210a5a25df20">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2de9ec63-5e0b-4c36-a2dd-e33c36f0d20f">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_826f49c7-a642-469d-8552-78be5151f669">X/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6e94e77c-547d-4055-a8b2-1a694e8949fa">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b861f3c-e091-4317-ae25-466367fda3ad">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae30957b-c27b-42c1-bf24-330d5d3d828d">Entity Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_46e267e7-ddb7-4f9e-9701-9b820782e84f">(3010,0037)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4812b310-aa67-4370-80e1-e07b5b45ff41">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e9942a56-b15b-40c0-bf55-66ceff0cec66">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8df219f4-680a-4bda-8a4e-4007f7282142">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e61d2836-c703-48c5-8f0c-cc12a1b60c29">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2884571-48da-43f3-a53e-51aa26b05c32">Entity Label</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_352a5217-6509-41f2-93ba-bbf8caad7a2d">(3010,0035)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_da5c4f2d-e6f2-41fe-ba54-f2d5cf171cd8">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7174e6e3-4569-4a3f-bb55-8604b171d059">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_45760fd2-3e75-4ca0-922e-5ebe8b84d555">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_170d88d2-ca2e-411d-8bb8-3b9dabc87353">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2bc55ef-30fb-4a1f-96ca-64d58f545e5f">Entity Long Label</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6757cf5e-ca02-4c00-a2d3-1f00685c7f3c">(3010,0038)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d34449e9-88ca-40f9-8a38-0f88c20e84c5">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_37e99356-a347-4f68-af2c-3b5392fea052">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0d90bd92-6725-49da-b1f7-63ff6e1f6259">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_71a9279f-0692-4cad-8f50-171e2d633f62">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_129bb1d8-d319-4636-991b-3a0bbe6ffb80">Entity Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5a811320-77c6-4e5a-96e1-a12e4285f788">(3010,0036)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a2c01e80-3e11-4a78-8599-2b39e95b4620">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_df980e89-fa12-4875-997d-2a7a8e2eb7e8">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_79584181-4a44-428a-89cf-04f3b8383d07">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f778bf57-eaf0-462f-accc-39615bdaff06">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a50269e-ec7f-42d6-94f7-412d709644c6">Equipment Frame of Reference Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7369d122-c0e7-4ded-8900-d1a1da62098e">(300A,0676)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c50b949e-48ee-41fc-92ec-5411b66de74f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0e1a09d2-22a8-4635-880f-a444501ac7c3">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a7452ce2-6033-4e58-9463-02c1c85d21d7">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c21c1f59-b74f-4b94-baec-e86d2ba99dbe">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f5f8e1a-0354-4d58-82d7-969aa604e198">Ethics Committee Approval Effectiveness End Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5d1a994f-5c17-4dd5-aebd-782a079f25f2">(0012,0087)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4e115131-3fb7-4033-a445-f6285569f649">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3aac87e9-e85f-4756-bc71-81a05d63091f">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7e61c784-ea17-4637-9e2b-9000db996d15">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_23785884-99cc-4dee-a6b9-204d8e0ea406">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_897135bc-844c-4cca-978f-3c0fcefa8adf">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_184ff85c-4dc7-40cb-9e46-b6abb62ee196">Ethics Committee Approval Effectiveness Start Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dad5725d-4d61-4852-b91b-216922e93f5b">(0012,0086)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5ec0e497-8e4d-4de9-8bcb-119370015954">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cbf3624e-986e-4da3-8ede-13a5d9db4dcd">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_25f239c2-c728-4a39-9b63-7f65ba362a42">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1aa6212d-651f-47c0-849c-3204da928cab">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bee5640b-24fd-49bb-966a-5628d47c9471">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cbfc33ea-86f8-4ef1-b9c1-82426ad1f6d0">Ethnic Group</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_251edca2-386c-4cd9-a041-93e2329ce96a">(0010,2160)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_51bac9de-c669-429d-98e0-b62818512c29">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bf82f485-ce36-4aa5-b908-a67688f6f68f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5ceaea19-e403-45ad-897f-7e212326e56c">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_30416bf2-fd9c-443d-9aea-d1a02df20f60">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22a9c4ba-937b-4516-af83-4052c959de24">Ethnic Group Code Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4aa06b9c-2604-4a17-8f0c-a315d8337a4c">(0010,2161)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d814b653-d7d2-45f7-a062-a3264d3b30fa">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e76a034a-9c5e-4552-ad20-5fe0ac378a27">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a667c868-64c8-47b6-b63b-830b65a86959">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_20a1fa97-3850-4c1f-bbea-279000e37264">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4757b15e-94d2-497e-bdca-ccc6d695b2d4">Ethnic Groups</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_68433195-7184-4569-b596-90378a7bc3ff">(0010,2162)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_32394422-0525-49f8-a53b-e49d93835e65">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_72e49c84-4676-479b-9e81-336e5b2379e5">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e97c408a-7e48-4681-87de-2984111f51fc">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_831e8d23-56d8-4f39-9256-eb9f214f7d57">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a72a74d-100c-41aa-a87b-96f08ab6d068">Exclusion Start DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_87120100-4dc3-440a-96fd-5799e20c1b71">(0018,9804)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_674d3954-a0cb-4748-94de-23c444624f26">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e0fa1f46-b9b0-4650-9d3b-eab3c382cd11">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a684c523-4f18-4897-9450-9ddc2bb498dd">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_64350e29-f509-477a-8f31-1dfe6bb3e7ea">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_37b259a5-ca3c-4ac2-bde9-f8937e42bc89">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3892937a-aff5-47ca-9b96-813b9c97ee2d">Expected Completion DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e334b35b-ab08-42d4-8421-118aef1de2ce">(0040,4011)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_87f5162f-d15c-4ac8-835a-c07b6c117830">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2837428a-c760-4b0d-a050-79a5589ef60d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8ed8c4fa-dcf8-45f5-a50d-a88e0a1d675d">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2c4e6234-56c2-4574-8cea-bbd4245eb71d">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f5013827-d065-47ac-b5c0-082abb3002e2">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a12aecee-ccce-49ea-a465-7c17c92c08d0">Failed SOP Instance UID List</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_74dd266a-daef-4242-a574-8a84109320da">(0008,0058)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_10eb7789-bf6d-4eec-9e27-1b838a8beca8">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0960f404-ce35-47cf-833b-01cf72955110">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e0dd2acb-440b-4806-b982-ee21b0960528">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7693c0b0-a318-4f07-97d8-3be67bf26f86">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0729dbff-21fd-42b7-81c7-e7bc7cef99e2">Fiducial UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6a73b277-dec6-4108-bc49-c7516041ac4f">(0070,031A)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_479cbbf2-bf6e-440d-89a0-1065655ed06a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7324d50a-42c9-4377-bbc3-eefe67f0a94c">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_92c5b891-0804-4077-b54a-167e04369bda">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1dae6247-6758-408d-bf0a-3c78ff706733">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4de00d32-85e4-4ee3-9198-1d8a1f99dc45">Filler Order Number / Imaging Service Request</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_44a14481-a4ab-4230-88ad-60b4fc2491e8">(0040,2017)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f4d60824-2f3f-4ab1-b069-6450ee372dd1">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_56b042a1-3d57-4f92-bef1-d1ed05931977">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0e3de874-4538-4e37-9332-e5ceefcadf8c">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6dc3422-d6ff-4e42-b6a4-bf4566cf0140">Filter Lookup Table Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d8b5b658-36fa-43b6-8d87-bbf75b0785b9">(003A,032B)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_47155e8a-c4e2-45e5-ae45-df2e12e640f2">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c904c2a3-34ce-4a96-9887-d84bcae1829b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a9275486-2ff0-4b68-889c-d516356eb86c">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7e18efda-bb44-44d3-88b7-f26f72b9ff2a">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_328ae33a-46dc-4f5c-93e5-bbf40f55ea28">Findings Group Recording Date (Trial)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_da04030c-463b-49eb-a59d-efbea00dd5d4">(0040,A023)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d9ed735c-8aa0-4eba-b7b8-6a4fc5f8ed3a">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f6e57a2b-4bb0-47dc-abd5-160457a372df">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a1e3d7d5-4c0c-4105-82d2-fa139270342d">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ea13f5fe-4588-431e-86ad-641e82a8e115">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e3c08edc-7523-417e-b6da-677049ae1fae">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dca5f5c9-c986-41c4-83ae-294793a424c2">Findings Group Recording Time (Trial)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2616c10f-a599-4303-9a6d-8a9c76254df9">(0040,A024)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_50bc8142-1265-4ab6-8fdb-95b06f653910">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b8a15ebc-f499-4cf7-a43a-2940291949fa">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8937ff75-c4d7-4f3e-8945-305615f29912">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ef6ebcbc-663d-4f06-a0d6-3d5776878ac7">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7843cbc9-fcc0-4ba6-92ac-24f47c78a96a">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f43fa3a9-c1af-4100-bbf3-e1c72f0aa0bf">First Treatment Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ad656ee7-aabd-4fb9-9140-39d41328ed70">(3008,0054)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b773e171-4ea6-4a75-8eab-435e771c19bb">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_706300dc-fed4-4c0e-935c-3f2b07d249a4">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_13874eb1-7e33-42bf-a420-0cbaeae8d41e">X/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0d58658b-8c95-4838-a434-8d63b8ee1e74">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9c972223-f05b-4bfc-be4f-75df108af8a2">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50a92c6a-b4fd-41a8-baed-6d81d79e6182">Fixation Device Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9ce5fd60-23d9-428c-8df7-f7b864eb6bd5">(300A,0196)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_167fce2f-4540-41a0-8f44-733bda920b5f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5b2ddcf7-d6cd-4d4b-8696-928d5332a7cc">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9627acbb-8cac-4688-a663-f6f40900dcd1">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a3698d1b-ff07-4470-bd2c-57bf8eaf9025">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7cd87adc-3ade-4f95-b23f-90f0e302931b">Flow Identifier</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c6f4a1a7-e029-4f9a-b109-712bb5cf8de3">(0034,0002)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a88ac4ee-b733-49a2-a76c-a33636acad6c">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fffa7753-a757-4730-84b9-189d92b6c27f">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_83227907-60ed-46a3-a3e4-f4ea8750bba2">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11e15dff-0709-4b37-97ee-d2c0d565dcf5">Flow Identifier Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dea9dad5-4dce-41f8-99ec-894e57adfca4">(0034,0001)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_26cc644f-a205-4e80-accf-9f3326c3ce75">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_163b4e00-5089-42df-b46c-50bafb584fbb">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_79504cf7-a66a-4ef8-945c-603f56726dde">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d8d0b46-5e9a-4fa3-8677-8ce60b771903">Fractionation Notes</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e08b429b-5642-4865-9cc3-96fb23fb8ab9">(3010,007F)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a06a037c-11b1-4d00-af01-2173eed3de96">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_45eb255a-f4b6-447d-a87f-235c9aa752d2">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f83b87b2-c055-4bf2-8e40-909ec823fc45">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_33165b41-08f3-4e8c-b9bf-9180a0487040">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_438b50f1-55a9-4bcb-b845-e2815e28f401">Fraction Group Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6abd97fa-7f01-49ea-87c9-0c68891a7f8b">(300A,0072)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_24600cad-3803-4bc6-927d-dd3ae6e58bab">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_87f859bb-70fd-4676-95f0-7b2b2b5a76f7">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_191fbe5d-e0bc-4ec8-96b2-156c7219541d">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ce95c397-b64b-439e-8654-4a3cc6d5813d">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d80ef817-ea3f-46a8-9350-6ac8a30acee4">Frame Acquisition DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_827050ba-5330-48ad-85a8-445100f40b46">(0018,9074)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4c7b92d7-aacf-4a34-bdbe-b1c7a1cd1656">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_efa0fdde-ec4d-41ff-9234-43baf78d5aa1">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a3cdba9e-4315-472a-85a6-c26cd1222844">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_21310f8b-02d5-4160-9177-5aa0ce241a06">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc8b4f1a-3a9f-49d8-865f-dba4ea0f2c22">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b8246091-f030-46c7-b793-01c62aba4e99">Frame Comments</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d4cfcfd5-955a-4a76-80e6-91512a4e7138">(0020,9158)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9d9fd646-ca98-489d-841d-dbd821916b43">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_55069e11-ecf8-4ea1-86c3-c30fe968cfa1">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e9ab442d-ab87-418d-ac6d-83c8e9f78421">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e306d8e3-67ab-4ca2-bbf6-7ae3022ad9a1">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b9e6256b-6774-4792-a413-cfbe4f3a5fdd">Frame of Reference UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2855cbe2-efa7-4b8c-998d-a5172feead4b">(0020,0052)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_99e7661a-e73c-4d9e-9c8c-ab61baabbdc4">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0ab46975-6900-429b-a987-c93b667cda62">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_95ea66a5-ab51-4d92-ac9e-fa3221ea1e43">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3435ba7a-e27c-41c5-bb3a-eaf1748ed85b">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f5129a7-0559-4d4f-b886-7d5139661b52">Frame Origin Timestamp</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0916e594-6da6-4719-bdf8-ee05c27a9f25">(0034,0007)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_addee5ac-7c7e-4135-8487-5354f7932ba7">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_11a647b2-d854-492f-add3-b2e50d2c2dff">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4abeb760-430a-4e74-bbae-003b53addc22">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_018f4571-a912-4a4f-ba21-813c5813c5f6">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6d8ca9a3-062e-49a1-bcc4-494239f7b8dd">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e28376d7-c0c5-4c3f-ac86-479963410e32">Frame Reference DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d3bf27fb-8ed2-42c7-b5ae-77d260946f8c">(0018,9151)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fe4663e4-db6c-4cc1-88ac-51b5c7901a5d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f6eb781-a488-49d8-8ffa-37e9b3131129">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_21b26746-e4ec-4429-aa5f-a431869223f8">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2f12dc26-7325-4a1b-8312-8a6819a2a2d7">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ad6ed80-1cf4-41f1-a690-ba778922e9e6">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_130415ed-3f38-4538-ad5e-39e0d7e665df">Functional Sync Pulse</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_09df8818-3862-412e-a358-85182202c4b9">(0018,9623)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f8d36a45-9ffc-4a9c-8aa3-fdeb767e162d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7698dd14-1a21-4aaf-b385-8d861789ad67">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e667f303-e6e0-4829-9785-9b5a22c8e2df">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ddec7eb3-5282-4d76-9493-cbe72abc9d40">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_12d0e8a0-1d07-4f1e-82dc-2dc814bc3c6a">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8c91adea-1549-4119-8a98-eb07de1b13c1">Gantry ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dd45b8f6-8963-4aed-842f-4cd3cedbc8da">(0018,1008)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4fd6759f-90d3-450c-a84f-60514d434529">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_89c35752-7466-476b-8e82-632d1500c21b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_97411cda-758f-4db5-b619-4a5217f67850">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0c480889-4e11-4b48-9842-fe9fac7e8516">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b87dda54-10b4-4e2d-b9de-d57f8d0438ff">Gender Identity Code Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b0eece07-dadf-46ad-af67-7827522d03a0">(0010,0044)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_048c8f5d-5d1a-4f8f-8999-683289b44427">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5dc05547-f68d-486a-8510-558e308f9245">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f3ad2770-5f1d-45c7-938c-066b14bf39d0">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83131bad-b7c4-420d-af67-b647b3cb5c67">Gender Identity Comment</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_007a398d-856d-4082-ad64-f1a64960b1a0">(0010,0045)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_481542b9-efcd-45f3-9159-6a8ac7d0b5ce">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_60375a63-ec88-4dcd-8b21-66b8925ac64b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a2b6e4fd-b60d-478f-aed7-226ecd238f86">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ef5651d-7201-4def-8836-beee16f6b827">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_997cf827-1c22-4e35-b8c4-9a1c89d580f7">Gender Identity Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9cd94833-3be2-4c25-8b5c-fc6c6a009bee">(0010,0041)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2502548e-0eb4-4dba-9cf0-8d14204b7ac8">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_215d34ba-430c-4d8c-bc89-bd1dc05b734e">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_945691b2-a792-4507-a1b5-85698d71ec5e">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b8ab7fc7-b3ef-4e5d-a1b6-6843ec9547db">Generator ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_db96c547-f73d-4e1a-8631-3eca2a6f90d7">(0018,1005)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_90eadbe5-a9b0-4060-a8e2-81f31a1b8dee">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1c6641bd-107d-4deb-a5cd-fea09d1f2e18">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_58444ad6-463b-4d20-964c-a5de58b86848">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_68f6240f-b856-4315-bf86-a7cb14112e5d">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f14c817e-bbba-49b1-a0f9-114830e3e366">GPS Altitude​</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4eb0e8d0-4af5-4e78-9883-f4ca88efed79">(0016,0076)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5f8e5803-466c-4464-ad38-e76dd506e5f0">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_da10c87d-15e5-4123-a662-8d2b530c3ce3">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a5b90c3e-2d56-4ea5-8495-fe68cce3b6df">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5278fb77-84a1-4c2c-842c-c740bd67d185">GPS Altitude​ Ref</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_92b4ae52-8958-4f5a-90b1-bd9de0c270a0">(0016,0075)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d1dc1c8b-4e10-4392-8699-e95575479cdc">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_93983767-4874-499c-afe5-dff9bca85c80">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cde91b56-7231-4a28-a769-8d46a2f8278e">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3681640b-5695-4a95-95fd-5e2c0f209ae1">GPS Area ​Information</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_df7d1247-ef3c-4d4a-ba08-8456f493be5e">(0016,008C)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_715f0b19-93fb-46d0-8f54-ae9231e9cd42">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7764779e-fddc-49a4-ad1c-e0e05602baff">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_786e16ed-b765-4ab5-a96e-53e47d36d554">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5855ed2c-76a1-48cc-9887-93d0d072a31e">GPS Date​ Stamp</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ef662972-c819-494d-ae29-32abd6efc237">(0016,008D)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_84ac6705-ff9e-4ec6-b3c1-a0a43f3c7fd6">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_18311dfe-e511-42fc-b917-a59658190077">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dde117a1-d7c1-4f8b-a1e9-525744a4f9fd">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a65a2457-13a9-4a7d-be46-4c22cab49888">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5a951fc8-466c-43e5-a6cf-d87cff9b6e37">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a8940b1-4da7-4e40-be80-afda1a0ada57">GPS Dest ​Bearing</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_da14428d-ee3f-4a97-bc4b-5422816c96c9">(0016,0088)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_74724881-cdaf-431f-8b32-c3bced4185ff">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b7b2b304-743e-4aaf-bb76-0c5e74cbfd8e">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f03ebe4b-b5ae-4bd6-bb82-11299d483c8c">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0bad7739-2e39-499c-a9f4-e6a4d4e5fd06">GPS Dest​ Bearing Ref</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f724db12-d615-467b-883d-7e1096d5ccc6">(0016,0087)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_741d79c6-8a3b-40d9-a685-25694058a2af">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_535b0c86-0b74-4331-8879-1ea4ff4e3b77">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9828d7c2-4bd4-4f4c-ad11-5a925997ff5d">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03c8148a-25b6-462a-a902-c5d28d034d3e">GPS Dest ​Distance</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3dd6c1d3-74e1-4608-850f-7520f909c16e">(0016,008A)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2d106de4-1a2a-484f-b108-653d0c64caa8">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_53243db7-c034-4f2b-9c2a-14a2a49e53ff">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_16862998-feb0-48a6-a3ae-28998ec478d7">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7a514ac5-c501-4df1-a7c6-8497aeae7efd">GPS Dest ​Distance Ref</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4666d027-7685-4ba9-9e85-ea11fc28e86b">(0016,0089)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3ac389e7-a58d-4fd6-83ae-0e435e1508d9">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fe65f830-71f8-440c-ae1e-d868b08b99cb">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d953337d-2af6-4506-a8f2-ce32033573de">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba820250-aeeb-4985-ba06-d4847b59d733">GPS Dest​ Latitude</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5807d4fb-9bb0-4eba-b20f-0f1b52670659">(0016,0084)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d4a06ef-1a4a-4055-9043-9bd3fa7dd12f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bdd1cd8b-f92b-407a-9bc6-a7abe3918521">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ce93e856-f9f9-4b72-b245-2a0a6348206b">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_edaa825e-62e1-4a9d-bcfc-cfb86e960af0">GPS Dest​ Latitude Ref</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2f5d82f5-1089-4723-a0d2-d0abb65a06c0">(0016,0083)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ffde4bb2-0dae-4d23-804e-9c35bf9b9c26">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3a4dd67b-6ddb-468a-8b8d-e6a20aa0e08f">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_015f5a5b-30b9-4c4a-b251-d0ba684a1814">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29a46769-c168-4e92-9205-860bac172637">GPS Dest ​Longitude</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9072d81c-689a-4de4-8a5e-e4d2715fac61">(0016,0086)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e580f3c2-1362-4452-80fc-30ff10ce453c">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4eef927d-0540-42a7-ac5a-757446b354aa">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4f3ffdff-ca48-4b79-bdef-4b2113cbcaf2">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65d19612-d8dc-4d55-a20e-210614b31c52">GPS Dest ​Longitude Ref</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_084e1ce0-5456-4110-8128-554197307a4e">(0016,0085)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e610b7ac-18ee-40b3-b510-73bc15b12a73">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cd557ed3-a8c8-4ef9-a910-2fb70b17d4aa">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dd8b0585-cda4-4243-a3b6-d7d4f7d88c95">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d9afd22-b352-456b-a50c-7eb86523643c">GPS Differential</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2344871e-0900-401c-9205-b9a8358331d6">(0016,008E)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ab38ce38-62a7-44bd-8401-2df8731a0d33">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_318c6afc-e290-4222-8ce8-e905959f0fef">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ad910469-6510-43a4-82bb-2546939faffe">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_228c0b71-815e-4305-b545-467fb96b7984">GPS DOP</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_72c2be38-6f40-4807-8a1e-a17a433623fd">(0016,007B)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_27aa86af-78d9-4823-8a70-2c87e9e0e132">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f863f301-3970-4c6a-a4f7-e1dd656f556b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5c1c8566-4fa4-4ac7-8121-c3fc29fe0c26">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29ef8665-c8de-4c3c-b2c7-678e5e4668ea">GPS Img ​Direction</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3152287c-e609-4834-bd0b-bc4e3c553918">(0016,0081)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_54fc9540-a6cc-4f60-ae64-476706346b95">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_48c98704-24a8-4101-8a9a-1b7502cab606">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_71e56f5b-784e-4bbb-a250-4189f17b6d9f">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ce374d2-fd79-4a95-a2d6-a5616a4210a9">GPS Img​ Direction Ref</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_117243ed-6d4c-4395-bff8-69836b78873b">(0016,0080)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_08ac2287-17e3-4d3b-802d-8d200d9517ea">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b34d7f4c-a723-4c1f-8c56-14a617d4dcf0">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85d6c75f-58d7-408d-a191-2828305a19da">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63d463e9-6fad-4031-bd70-63f13ccd045c">GPS Latitude​</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d3ceda9-5290-42b9-b6fb-dabca2d75c7c">(0016,0072)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5baf5123-e031-4e2c-80d7-027c6364bf8b">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_49346cc2-2cc0-435e-9b65-ef7a66e52512">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5e299d6e-586d-4c43-b8ab-55deb634b44d">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4fd14bc9-7280-4dd1-9179-c89ddcdef733">GPS Latitude​ Ref</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_804ed40c-f2f0-477a-8ffe-c2a321d9d540">(0016,0071)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5a9c0497-8d9f-472e-b4c4-8e129b36b0c4">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6b7bcee6-ab48-46f7-88d7-59e673ae2fca">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_40e4d168-a414-4c8c-9563-725b24640bcb">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7cea45c-a70d-4b0b-bc27-985f35aef4d5">GPS Longitude</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eb05f6ad-e97d-4f58-94f2-d474cc6ff9c8">(0016,0074)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4715d47a-3699-410d-b337-79fd0467c4cd">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_31b928e2-b597-4276-9a2b-b9bb197b9adc">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_56896bdf-e1b5-4a66-aba6-b050539acbe2">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed1b4e20-8611-4821-a9dd-49903ef1a12a">GPS Longitude Ref</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5436f975-e558-4e30-92c5-5418a0fbbcfa">(0016,0073)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_12a93b6d-f6e4-4385-803d-cab250c8e651">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_15894387-e0dd-4df5-aa2c-29e0f8168fa0">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f2a6a994-4323-494a-8aac-b8649dd04e5b">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_638fd4b5-8d74-454b-a7a9-2656aceebbb3">GPS Map​ Datum</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ff9c8727-bd4d-40c2-8a7f-5a4309e6931f">(0016,0082)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_982c861e-e5d3-4a67-9451-ecb9ea8ae183">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_50f3948f-b5b0-423b-93d0-7c16ffa79a92">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e110f52f-41c5-4cae-b2e4-1ca532d9fc4c">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a795f90-48b3-405c-a3e8-d16771f6e8d2">GPS Measure ​Mode</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_433b0f85-d785-4815-a24a-2181712fb163">(0016,007A)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c5a6221b-5cff-4799-b4f9-78452e1f2e62">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_24c58a2b-a9e0-4ca2-be8e-22e8c2bfffe7">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_817a4715-1fb1-4870-a9e9-78cec999ed4e">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb092fc5-697a-44c6-99c6-5ef287fc5389">GPS Processing​ Method</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_96708f0e-da3b-4ca2-95fc-2586287c59e5">(0016,008B)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8d1923f9-6a29-4387-a179-e079b92f27da">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3a8039f6-faee-4e49-ac60-53fc2335deb7">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_741cbd82-f709-4f9c-9ef1-5a6ab9cffd6b">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_157f5a08-58f0-4e91-8ecc-6fb608918c2c">GPS Satellites</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d2b7dddf-3665-4c0a-bb95-35e96919aadd">(0016,0078)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5250bceb-6e26-4a2d-ab25-99dc70d33528">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1e77a450-a7dd-4ca4-b101-dd70c8d1400e">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eeafb4a5-f3ba-416d-a387-e08f33d8082b">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce133ef4-9dfb-4751-9e85-cd3cf7072a90">GPS Speed​</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a872152f-35cd-41ec-9ebf-b13d4fa8fef5">(0016,007D)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bd751666-2a2a-4702-8609-8155cbdd85da">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_00d3d4b1-f940-4d3b-825c-fef32b1f9ca5">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8e3c1ee8-179e-4f61-afa2-3625960b8167">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03294e7d-22bb-402a-9a33-0d089cc83b39">GPS Speed​ Ref</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bb041af3-66f9-4f70-a8ea-84d8c67eee7f">(0016,007C)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f59f2e8c-848d-4774-b9fb-eec4b5fbd725">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_06ba3b51-d8c7-4692-947a-d31542409443">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f89cef49-8a92-46e9-933a-9c33dfd7914b">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35b7cd85-e38a-4e2d-930e-d4dce6738a85">GPS Status</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e68f4856-7e71-4339-b37f-24c11d624cf4">(0016,0079)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8b1b20a3-38de-4f2e-b443-3d5dbdf72c14">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e0812b54-487d-40d9-be55-035b1d8c1828">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8e771fce-9c36-4d81-adda-af4e1154539a">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ddeb5eb-ee46-4715-84bf-90c38025902b">GPS Time​ Stamp</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1644f222-93ad-47aa-8bbe-25d15d0c5cb7">(0016,0077)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6315bd98-8102-46b3-8dff-ba2b6a61c46a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2d69dc25-ef4b-475e-8438-c14a96274aba">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_21ed7ac5-8599-4c69-973d-066de4fa4266">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8b2217a-da7d-4d0b-9f22-a0bc67f23539">GPS Track</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_93870ff3-366b-4fad-88a7-c08c3c6c25f9">(0016,007F)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c068a20-1ddb-4324-9fd4-2c0b209e6de2">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f848a6e9-ecb8-4d32-8909-b2a29c4dfda1">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3f30bfd3-801a-4cbd-9181-45aa28ab8969">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5528312a-dceb-4f7f-a07c-ac92a08041e0">GPS Track ​Ref</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c64a4ad4-0c65-4fb1-bd0c-61c56611eed7">(0016,007E)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_77d99b25-a4a1-4d9b-bac2-66d5fb87d0b6">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_70ef8832-69c2-41e9-86b7-eb0e525f035c">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cd781199-d4d1-4b0f-80b0-56a8e23968c4">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1e79173-664e-487a-af36-e3397b85c07c">GPS Version ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4eb90b60-c2ea-4edc-b702-f7e012095fed">(0016,0070)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6706d9b0-07e1-44bd-806e-a9cc6d902b00">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d24dcdb3-a46c-490c-868e-51e54ff4a7ce">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_543ca8ed-83fb-4e48-810f-17678f29cafa">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_78aefe98-aa9c-48a6-baf2-c0e4a349beea">Graphic Annotation Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0850bda7-2545-4b28-b48f-2ff51fed812d">(0070,0001)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_449c8ddb-315a-4734-a7d3-953fdf70500b">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_27669d0d-50ae-430f-8de0-95e1bf272c52">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e5f9d9f5-15fb-44d5-8f55-bfccc51058e3">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b86347f4-5e8c-4160-8b6c-b878a6bc2b27">C</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_15c8f257-41ad-4893-a4c5-48531f64376a">Hanging Protocol Creation DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9524d2fa-9817-4a21-a500-c0df8865a311">(0072,000A)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7a85a56b-1411-427d-8311-cb92cedf2a2c">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_78b1cf7c-8d89-4a34-817b-f420daa273dc">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_719458c4-7647-4a85-b551-bd90104e9ee4">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_10c7cff4-7784-467b-a96d-befe5c2fbb83">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b7086150-5279-4d01-9366-51ff7d0412a6">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e1c4a7b0-8b1b-493f-87d4-4e3e117a6cd7">Hardcopy Creation Device ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1c8c69fd-2a3f-4528-a144-a34764e94532">(0018,1011)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a0d2ebe-b8e9-42c2-a059-70b880826eac">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6a2f65dc-e9d8-49e6-8613-36a8ee0f2905">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9b620696-4666-4076-b9c5-c91d48c4ddaa">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_530b643f-ad14-4ee7-a217-cae47cbb3a77">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5eeee34-508f-48e9-8465-81762929c0fa">Histological Diagnoses Code Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3eaf9002-dd3f-496f-b466-dc2c7d70857b">(0008,1304)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9f589da1-665a-4123-88d1-473c3b03f453">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a41c5484-9b09-49b9-af50-42a315e53344">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ebc896f-5d2d-4934-bef5-ad63af0017ab">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_983d6473-f42e-4732-941b-47534353f4c8">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c6503c84-1a78-476e-afb7-e4657b292a6d">HL7 Document Effective Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9ae46311-76ff-49b6-bf88-c5abbcc7216a">(0040,E004)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7c6254a6-99b6-4224-9c2b-87eb5fb82e16">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e6570df4-ecaa-4b29-abcb-2e234aeb29b8">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5b840959-fa61-49e0-aaa9-cf7b0a9928f3">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cc592b14-8f90-4c39-9026-ff4c289596b0">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_693d4393-641c-462d-8ce1-b38e4b14e25a">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f92d9610-539d-4f05-842f-3656b7f2a109">Human Performer's Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_64008220-542a-4ea7-aa06-f71110f9ae74">(0040,4037)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2517ad43-b843-4fce-a9e4-538e1e1f5dbc">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_47557f37-16e7-46fb-8276-a784d360becd">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b09c21de-e2d7-474e-a31c-de2e6023941d">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3937b709-5844-44a7-bc7c-901e2c590051">Human Performer's Organization</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_edf4dd21-f718-41aa-9827-5ecdb71da021">(0040,4036)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ce31c766-1f0e-4c24-8ddc-e5b1d47d56be">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b0ee2192-ac87-4760-b688-4062d760bbf4">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f3623ffb-d86f-4f14-ad07-13cf7911117c">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1680ff35-0fb0-4a12-8694-e532399b8979">Icon Image Sequence</para>
                                <para xml:id="para_59c2c83e-30f9-4460-9a4a-e85c9491d678">(see Note 11)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5437634c-a273-4128-9d4d-52237745b1a0">(0088,0200)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c18c9981-b4fa-42b5-ae9d-abb43de86aea">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_926bc76a-e122-4707-bf60-3958c319dd2d">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_afb570dc-f28b-47b9-baf7-abd4eefc790b">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ef6c43f-3ba2-4118-ba05-59ce128bc9f1">Identifying Comments</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a0e43a4-6edf-4346-875e-2414af9a0c4f">(0008,4000)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f4f0456b-8404-4964-a928-4d491d5cf79b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cca3d680-cb3c-4559-a114-5958396ae716">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_04544ee0-bf58-4113-a74a-6b9b689d3245">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_35870991-47a4-4209-8a0f-edeca98e35d7">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84459d20-dd8b-4302-8eba-fb12c926b26c">Image Comments</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a2462382-8af0-4cae-8437-0c0d88976584">(0020,4000)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf5784d8-35d3-4824-9288-aabddee66302">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1d68d573-e257-49df-b31f-d6447d1e9e31">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b801fd86-acbb-403f-a9cc-c9cb272cbbce">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7ec97cf3-7e59-4bd1-95e8-d029059b1607">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9359a694-e631-46b5-b168-2b0cef123b33">Image Presentation Comments</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_34690fbe-4b8f-415d-aed8-9a661a16bab9">(0028,4000)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_86b9e99b-69a6-487f-a3a0-99b97577aeaa">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_986e0635-5e9b-4551-8698-154a9415ba52">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7190cca3-b784-495e-910c-cdde6fa70f4c">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0b5645b-1874-48f8-ae60-0933ce4fcc6a">Imaging Service Request Comments</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2fe26efe-01a7-4ccb-abdc-7d23cc008b4e">(0040,2400)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ce6d21ad-998d-4abc-83d6-50482cee9957">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_757fe44d-e686-460b-bb4b-7904d2f724c4">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_774d639f-20c5-4849-a0b3-d225cf4d83df">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6174f23c-4d0a-465b-97eb-a6201245d8f0">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a22eb4d-46a3-4320-bd6c-641ebff82fb1">Impedance Measurement DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0b0c32bd-04c4-4e3c-b364-92d15f35285a">(003A,0314)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cb9a7ac7-0245-42d7-9a1b-6af626e0b264">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2f199d38-bfa2-4278-a34d-e7faf361a458">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_63697939-b379-4854-bb8c-9f6bf22e36ff">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_41ea8ab0-a010-4378-b381-703434e2e5c1">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_22f34f31-2e0d-4eb8-8886-2b0fe654d236">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e68a91ad-0461-4482-95d1-92a55d30862e">Impressions</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_597fbd63-7bfa-4f0f-b58a-287bfc46159e">(4008,0300)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6a9badf3-d13d-4ad4-94b0-7ca1a906c70f">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d6bb004-be2f-4cf7-8683-a818f0413e51">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8a5c4555-a5a1-4f8b-896b-b07b723f2e58">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1dd86b3f-3a19-48ae-930f-a0df498be2d9">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00b27a2c-74b0-41c3-80a6-f9037e49bd81">Information Issue DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_060a4f06-24d4-42b3-b753-325a0563a95e">(0068,6270)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0b80cb89-d1b4-49ab-a863-ccfa685b3dd9">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d0594169-d348-45a9-931c-f248f8a67257">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9f939c0c-a6de-4f6b-a967-86d903ed1938">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9de67ef8-45a4-4bda-b24d-cefd83738d43">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_28f88e60-ef81-48c9-8364-0a68fd16be79">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82b95934-a208-40d5-ae04-4738911f9d4e">Instance Coercion DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_77338cd1-6f1e-43f8-b6d1-644b764d9f19">(0008,0015)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6818656c-a292-4914-af9b-9d2d79076a90">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_565f4ae7-236e-4f1f-9e44-62aca2ef4fd8">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0c87d3b1-20f3-4fa6-af62-03f850a0b5c0">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ff6703b8-443d-44a4-ace3-c650d3172711">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b276d147-6a60-48a6-9610-120f457626c1">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b10dfa36-937f-4f16-b8d2-990666cef19d">Instance Creation Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f9b52451-b036-4239-92cb-ac16039267a6">(0008,0012)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c42335f5-5876-4c69-9f94-6ee56133b55e">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9ad96c98-78fb-4dcb-8cd3-3e1a8e07e9dc">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2cf550df-b13b-49a3-8f38-0c2f41001ec5">X/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_21294718-c458-4043-93e9-3eb59fdc4d3f">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8bf1ddf0-1ae6-40be-b857-e28470bfe42c">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_029e91be-0336-469d-a979-48c8401c9931">Instance Creation Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_24da8861-b331-4a9d-9712-16c16a0d684c">(0008,0013)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c1e7e2d-761a-450e-b358-9cb1268584e0">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_49e81580-12cf-4379-af9b-e5f716c77dfe">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_344935fe-3b4e-42b7-8422-b195cda627d0">X/Z/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_917fe0db-5832-4a91-b242-5fc01e8bf000">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0e3fd8f6-c15c-449c-add7-2a289bc4440e">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f382d8b9-aab0-486e-aa70-9ddf2f38d08a">Instance Creator UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_81c29bd4-04ce-4fd9-8108-d39447ce3e62">(0008,0014)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dd41b446-58ab-41c9-a725-62d5e0906bee">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b9fdc7cf-34c2-485a-ad7f-772b857f64cb">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c56799f4-2350-4527-95be-8b2b9cbe9870">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bda6ddf1-c6a0-4415-99e7-3a708a03afb1">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fed896a3-78ba-43d8-ba5c-5101f1e129a1">Instance Origin Status</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cd33fa62-498b-4251-b707-45258cefe272">(0400,0600)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_edc7121a-0047-4e5e-bc69-def452f93ed2">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fef36565-dc3b-4353-a431-b32dd003022c">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_95aa0e8e-118b-42b0-b6ef-b8ced2116797">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6aa6f9d7-5813-4ac5-8923-5ecc219ca87d">Institution Address</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_25f1bc9e-4cda-48b8-8e95-6eff0d7e6a85">(0008,0081)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_13264804-3d4c-4d49-b2ba-44cb8afb36b6">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_32fcd954-8360-40a6-8a28-ccfd3251cabe">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_969fc534-16a8-4e6f-bd48-c60450ebbc9a">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c19b41fb-52a4-451b-8e27-fa2cfb1e5b52">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_729e9053-6082-42dc-8fe8-5a626f401b5a">Institutional Department Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c71f71f0-bb70-4636-a78f-d1850848f969">(0008,1040)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d230e3b0-da94-432f-88fd-e4d08c4cfdb1">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_118df022-c038-47f7-a760-c2891353ec18">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_22adad3c-d0cc-4393-bb06-7665f352752f">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_90dd9c8e-26a2-424f-97f4-fef8a68f6991">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f91901d7-0f3e-461f-b1b9-bf7dfbe60a82">Institutional Department Type Code Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4b7b9a84-fecf-4cc6-9676-4d0572371f99">(0008,1041)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_adbcbe8a-13b4-4abc-8a42-b69b0863ab00">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_de73879f-d278-4ef4-b1f1-87ab18273653">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b4696a45-499d-44db-9b3a-ebd677016113">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e86be959-a0f6-4063-a53d-f7b492f8b8e6">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f18e6fd-6794-4cfb-b078-491103a88237">Institution Code Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dce8ac15-c514-4889-b0c6-4254ca6095de">(0008,0082)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_98567793-4cf0-4832-8535-11f6086641b8">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b8a46093-7f9b-4d71-b2f0-badadd4f02d7">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7c86fe4f-aea5-48e3-b84f-29d796b4ac56">X/Z/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9c5349f1-cbc1-43ed-a217-575e88231bd1">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7d790ef-20d7-42d5-a7f7-5782a6005470">Institution Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bdb7b517-8105-44c8-b877-f4dc74b529dd">(0008,0080)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5f0b3373-ada2-4da7-98d9-fc6b8809ffff">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_47312d19-e5c6-4092-aff7-1a2af88a160a">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a3d9dc1e-8786-4e5c-9e6e-fae5d8d7fcf5">X/Z/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_84e28e4d-625e-443b-9ea5-d40f1ba76ac6">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2e83532-57d5-4a0a-9576-000e834f7b68">Instruction Performed DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c8f42249-0922-4630-b4d8-d872c372120d">(0018,9919)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c18b59cb-9b0b-4e76-863e-edca5a90efa2">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ba2e296b-b7c0-4f2a-a6d6-4d0eceb5e561">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c38616e5-372f-4b2f-bb85-6c927b784c46">Z/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e653cb51-44b8-4e30-b87f-a0fc6af3db55">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b1ddb65d-2b1a-4ecd-86e3-6efa867b05d4">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_90c7cba8-8bd9-4f17-8d2a-415afa6c60ab">Insurance Plan Identification</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eaa89e0b-5853-4a39-9135-fd966798e966">(0010,1050)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a119f781-ec91-46b7-866b-70877561f6a2">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e848007b-9f16-4f08-ad56-f967f96dcc08">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_52f9f816-9f28-46f8-b6f4-0dc81884eda2">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8339e624-db7c-4b7c-8245-7d8ced6fde2e">Intended Fraction Start Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5cf39bf9-d7c1-407f-98ee-7a8d9b709b35">(3010,0085)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e8366446-8dad-4a4e-a1ff-f72d8fd98ed4">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d1198259-930a-4554-a513-93db510e7ec3">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_263529e0-0d09-4af5-8db5-28f187f9f4de">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1d69eb11-cf99-45d0-8771-c509fba52265">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_61d416e3-8df8-434a-9db8-b1d4c18cad54">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93380a6b-8a02-487f-8528-77b1b3a5e0fe">Intended Phase End Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73648944-f58e-4060-9a6d-c93f961828ff">(3010,004D)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_590c095b-387a-4e38-b202-e2c4279ec9ef">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d702359a-ed0e-47d7-ae5a-63cf63b03da0">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bd537330-d5f3-46bf-9584-112e4fc010c8">X/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8fef0046-b7d6-469d-87f2-6dd63b42dc55">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a2d89290-4974-4e90-9437-635f00158174">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_577950e9-f02f-4c52-8843-a53b4f7a42ac">Intended Phase Start Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6d77ec98-ad75-45e5-a99c-bb251a8818ca">(3010,004C)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_db3c6c66-5f51-4c05-9fc3-ee144d20d7e9">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_15cae992-ece5-4c07-88dd-02058d5d057e">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e75748ac-a2aa-4ae7-aefb-db7bdcf5de4b">X/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c425ce13-3790-43ba-a824-e6f665b90c9d">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cddeb16a-15c8-42a1-87f5-c141d4d3dd35">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0cd12b07-197d-4e3a-b1e6-779daa102e13">Intended Recipients of Results Identification Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_77baee5f-3abb-4e1b-9e86-5b0b620de124">(0040,1011)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aa1fb483-c275-488c-bd7a-3413b55aa5f8">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a7b70812-b1ed-48e3-a0c1-dc38e60e4d74">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_64b37248-e7cc-48c5-98d1-4e426cefdbe7">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72fbb1ee-bb30-43ae-8851-4b149bf3bd43">Interlock DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6fdd85a0-1cb5-414b-9128-c8debd0c82c6">(300A,0741)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f449ddf-80e0-438a-87fc-4ead4a0b1872">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_de7ed29b-e356-497d-8703-2d528ddf73aa">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_86868cfc-69b1-413a-a42e-64dd62679e33">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6de79689-b8e9-466b-bd54-c055ffed215d">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f6dd90db-b55e-4e7f-9b4a-ac56acfd371b">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37266c30-0369-41b8-b7e3-897af2f82228">Interlock Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ba15e521-fe20-4e4d-95d4-755720c2b537">(300A,0742)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7aea4b3a-6424-4222-b89c-89fcf079e636">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_43128216-b76c-4644-894a-4080df8d5fb0">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3fd44c21-6dde-46df-81eb-a5f2635d36cc">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c5dbf960-ff55-41bd-9f3e-30fb91b2db56">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b119b882-372b-449b-8497-d8ec76b744e0">Interlock Origin Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_60622990-4150-44bd-958b-7882f7216978">(300A,0783)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f80e5427-9ead-48d6-90f5-306d504f2295">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_15b05a4c-414e-4683-b577-ecc19a167134">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_30bc8712-3ffd-4a59-946c-7b5e846164f5">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_acd5307e-bfa8-468f-8e23-8dc2ca1e0d9f">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65ea63a0-0d3d-405b-b637-ec68c6358103">Interpretation Approval Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9850240d-ad08-4c15-84b0-e4bb9355062d">(4008,0112)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a86e39d7-7029-45e0-ae8e-312a81882635">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_257d72a7-9bab-44fc-850d-d7e397ca21c8">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e6847c71-0374-442c-a594-bd4ec1c5b6c3">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_32c49d49-e2ee-4942-8d17-5c1aa746b4ad">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c6883535-e272-462a-90ad-39d1ba7fbe59">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba33ac57-17ee-4e9f-94a8-89bfc240dbfc">Interpretation Approval Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7040568a-dd89-4fc4-bb83-40a44c5db220">(4008,0113)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a613a9b0-3c28-4bab-aa1f-5f0cb4f81b7b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5ddd2311-05f4-4db6-9b14-e1d8f3d6f198">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6fa92b44-ba9a-4f80-8c69-6079fba2e1c8">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73af88ea-61ca-46e5-8c36-763e85383adf">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4363cd61-ce19-42d3-bda0-6fd46f7c3061">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_07fe3d0f-26c9-475c-b6ec-4543f04c77f9">Interpretation Approver Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_56002927-ceca-44e2-8127-3d442235ff58">(4008,0111)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aeffddb8-9091-4bcb-b42b-3226a0fe7bab">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7f69cc5a-9497-4345-a866-fe99fd22fe8a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3b74d92a-162f-4d25-a2b1-a0bd9f3b8475">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8be751b3-b68b-4357-8d9b-babd90d7cf8d">Interpretation Author</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_84b61258-9e12-4952-82ea-b1cbdd6916eb">(4008,010C)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_61d217b2-3f6c-4d47-9c75-aafd729a66c3">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a9d2b21c-9f71-4376-ba2f-d7b0784976be">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e99d0293-b7d1-4a65-9012-2896c23a61a2">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_53b0df49-fc15-4962-8020-270906b6a234">Interpretation Diagnosis Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf51a6e4-4db6-4755-8ee7-f2828de391c4">(4008,0115)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_67fddb2b-0e95-47fe-a757-189be8f70182">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a27706fe-c11e-4860-bbb8-35a0210b7ce6">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1383c781-717f-4d0c-b6f4-b73e9aeaed13">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ca64e229-6045-43f5-b22c-4ca85c76bb7d">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_12f4c81b-54cf-4746-8696-8ab0c042b48f">Interpretation ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a69d0cb2-a925-4387-a59f-e46ec7daeb6a">(4008,0200)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf99d822-6072-4b89-9e00-e2367dcf6941">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b655b285-2869-44ac-833d-d4b76486bebf">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_10ff0982-ff2e-4069-8039-c840c96fd682">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c4dfeb9-acd0-4e68-a800-ffffcbb0ad6f">Interpretation ID Issuer</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f8db1eb2-785c-4a32-8e0c-610ecc29b94d">(4008,0202)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0daf073d-0aaf-425e-807e-988331f52a98">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8a10fb07-a9c8-4dc4-8c31-bc97d202c01d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_881a90b3-597d-4f35-85d2-ff4ca7377e84">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c58cbe9-6faa-4501-8087-dc4f495fc2fb">Interpretation Recorded Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ac95ef46-a3e5-4d75-a056-70b78a0d2f9c">(4008,0100)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_18ca6cc6-e3d0-4dae-b10a-c6914e921e99">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ab650f72-a8d2-49a8-8984-60415a16512d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_66cfdc28-43c7-44ae-ad1f-07e6d174f44c">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7dcce81a-b175-4e84-b5c9-c3ba2be58252">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2f0b67b4-4e37-4182-b75f-1e75d9a12f18">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d579d039-4319-45c9-90c3-dec0f0a562d1">Interpretation Recorded Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_771833c5-055e-41d0-8bdf-a998dc2272ba">(4008,0101)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0d7d8663-31c0-45b4-a4c6-2aa1e1ab454f">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_11bfe70d-78c3-4f11-96d8-92fdae447d45">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85b76e4a-5e5f-4db8-9410-dad0f344facb">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e2b64a71-8cf6-4495-89fb-b7910a0a63fb">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3eab16d3-21ea-43ad-b9ba-70fb053071b1">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4b2bbc4-a7b4-473a-93da-f49c9322861c">Interpretation Recorder</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_87c6dac8-d2bf-4c58-b791-18fa972b9294">(4008,0102)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e220f328-fd56-48bf-b2b8-e0162727a65a">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5995bf2b-a61a-4008-94d6-9d245056e398">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0a4ef578-50f3-40b8-9f9e-a3e22e848642">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bde8dc90-ef9a-4f51-8d30-36057cd56bce">Interpretation Text</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_30bc762e-725c-4702-91ff-22d14ee31277">(4008,010B)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7fb5e84f-8d58-43a1-b247-74a0ad8707cf">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c57ffda1-20ac-4da4-8700-9cbf925381e8">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2c9cbf39-52d9-4624-90ac-15ef39471e11">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_24b4ab0b-c7cd-4cc7-9943-d11341c71a4f">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d20060b-d6db-49c6-b893-b02b616850f1">Interpretation Transcriber</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_61a3142b-f68d-47de-98fd-c7e530a519d2">(4008,010A)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eb56dbc6-774f-4eb0-8eec-cdda188b9f56">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2a6783c1-0724-49f7-9184-6b3d826cb7b7">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_00032d63-3fc1-4475-8151-877bfe5cb2ea">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_09b4b05c-6849-4434-8be2-cb2e0beb5739">Interpretation Transcription Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f9976e71-c6ce-4e7c-86b5-9029cc878229">(4008,0108)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_52fda588-1336-473e-b7c7-06266bb780f2">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a8bf3bc6-1acd-4ed3-a953-5e4ac64e900e">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_952a37c4-557a-438b-ba89-8e2bf468fd9c">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e241fbe8-0b0e-4352-8bae-eb965cff03f2">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_41253b26-7124-4cff-a27f-8a7396688f78">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b6561b2-b9dd-4aa7-8da0-9c48009226c5">Interpretation Transcription Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5de09666-0b44-4d74-a9e4-2678359239cd">(4008,0109)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_45144729-6b68-4305-8c5b-adab88cdf4bc">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_82debdbf-fcde-4c62-b6cc-99427e6b1c56">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f8982dd6-616e-4b26-ba18-98ca7018f247">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3239eec1-1686-41f9-9018-e5341f80f2c7">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f076cba0-f8e9-46b1-b223-7b57ea34612e">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f94b4eb-4ccf-4816-a140-88591a44a1a1">Intervention Drug Start Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3bb458b9-8b78-4ee7-b49b-4fd1c8900b20">(0018,0035)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c2bf4e88-6902-42c1-9df5-9fed9b51ba85">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7e21bcd0-bd0d-4f48-80be-358c89ac4864">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1a68ee10-2532-4d3d-bae3-32e896996d2d">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_66f09886-8cb2-4073-9e3e-b63ec8548764">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7d0ba196-bbca-41a3-802d-d232c86ba965">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ea3fecc-ed40-428b-a706-d8562777bf65">Intervention Drug Stop Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0f6d5a3c-a4c3-46b2-a930-a1880c943f3e">(0018,0027)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_27f1039a-7482-46f6-b342-0ea72566b3c2">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85922d55-85e0-474a-b57a-46839ff85020">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f413bc8f-9a4a-4d17-9c39-3da0f49a5830">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_07809109-c21f-48b3-8ebb-aecae79c4d3e">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f04c1d81-351d-4a32-a8b0-c46757d2d5a4">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7cd526b-948b-42d2-a907-a844378de8dc">Irradiation Event UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_11fb01a7-5878-4806-aa75-5d8b36c68ee3">(0008,3010)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2d7f022d-dced-4fdd-8c86-f360413fdafd">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_05d3beed-bd3d-4b11-9072-5409e5449f53">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3366968d-373c-4dba-a892-ea1d3a8563f8">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b5d27d8-d76e-44b0-8114-41089f54ce33">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97005ebb-e392-4a3f-8e49-9a606884cd05">Issue Date of Imaging Service Request</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dfd467ef-b366-447d-94d6-1a18bfc180b0">(0040,2004)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_21fe4468-6fda-41f1-b3ac-5b51592cae2e">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_83afe72b-bd93-4343-8df2-dac1ffad787d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_902a6837-771c-468d-b04c-1c29c55ca988">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a15d76c1-3917-40fe-be6b-3a9133b5d0ee">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_13dbde37-e255-4b20-82af-bde484530a7d">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82e4fc0a-7fc4-4828-a1af-a6d825c7a2ad">Issuer of Admission ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_df2f5b85-674d-4729-8f97-3ea0f61edad9">(0038,0011)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5588a3c4-24ba-4cb2-9112-bbfc2231c7c1">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e816432c-bf8f-4d27-b668-aaf1734a8079">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ad6e3558-07e4-4ee5-9204-0b7107fe2bfa">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a01f21ea-0f63-4d61-a499-fa82bd5a14d5">Issuer of Admission ID Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8635e1a2-6554-4707-8d3d-f697b38c6452">(0038,0014)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5f79d45e-e01a-41d7-aba4-fb7594027ce4">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7f9b9a04-bf7d-4292-80f2-96b1c0e6d0db">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ebc3fc9c-614e-4c22-a10a-0e928e4f39b7">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9b85141-4f2d-4609-8aff-30e7f5283541">Issuer of Clinical Trial Protocol ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0a33f8ae-91ff-41d8-949b-a9a28d28db56">(0012,0022)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e6565781-2059-4151-bfb2-33df9d2d9633">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5dec3276-b2f5-4ce2-9a4d-b25b9d53d59b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4bf66657-62f2-4c67-88c7-9b9949988534">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93363d00-2224-426a-b9a6-617497c7ea32">Issuer of Clinical Trial Series ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_08a88639-4d77-4a57-8ada-747947dbfaef">(0012,0073)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_085c3299-4d7a-47eb-a483-832cc984c7bf">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1105c359-e2e6-4d35-ae3f-53f6375dbc79">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_653e38cd-e7f6-4ee8-afee-62c6ecb90fb1">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d03adf5e-2503-4402-8f6b-11199c536e70">Issuer of Clinical Trial Site ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c76630ae-f17b-4d5e-b4a5-0921b7c9307e">(0012,0032)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_23b097ef-c27b-4601-86cb-cd798d66b789">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a446262a-ed03-42c5-a703-81c41d2ff821">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_21540810-b807-420b-9a21-2ac401c1b4b9">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9105e498-e1c6-49cb-b3f1-fbfac9f9c1a3">Issuer of Clinical Trial Subject ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4f59220d-3d76-4846-9802-475e2c68c4d0">(0012,0041)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1adb9511-fce2-484c-a122-9f31b0369ff0">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_50989144-1470-4efe-85ac-9a46e58ea149">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_865919d4-83b1-4227-a107-a87e2865e863">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c379c1d6-3518-4dc2-8c2b-b4d4ca2b8bf2">Issuer of Clinical Trial Subject Reading ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_171203c9-bea4-4bfc-bb49-46c116775c8c">(0012,0043)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e3f61d75-3ac1-4575-94ae-dad262443164">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b340e5bd-c5c9-4f0d-bcad-8dd7cda760a9">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e8a5773d-03d8-4b91-8e1c-d4ffbd1b1d6b">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9fd7f0f9-b188-43fa-bfd5-85e899ef807c">Issuer of Clinical Trial Time Point ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2cd50b03-9a03-4b32-a332-f78468d003c1">(0012,0055)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_597331ed-65f2-4f26-b1ac-582a752b4d0d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a52548d6-b5f8-4f96-98e4-5d6e245337a7">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7efe7b85-da65-4b3f-96bc-699503c5b706">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58adc859-72a4-413f-96ef-2912e264afe5">Issuer of Patient ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1fb7dc82-6452-4255-bf22-bc73086e85e1">(0010,0021)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f82df6e1-e960-45da-bde2-cff1d8b70602">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_977929fe-8b9f-42d5-89e8-b5dd794591fb">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f1ca8ff1-f8be-4fbb-a706-5a9548690c21">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f78b4a19-154a-4577-9fb3-abae07f867e0">Issuer of Service Episode ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a0aa8837-7a6f-496e-a348-408e890613e3">(0038,0061)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b288c10c-6ec4-4b28-8862-a38b66063a62">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_df04bee1-95ed-47ad-aebf-3a58793fbfd8">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d249822d-f03c-4f14-b9d6-fafa9ab7b3d8">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b8ae877d-0123-4bb6-939d-750b1bb62ef5">Issuer of Service Episode ID Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c6f63905-e095-4c2a-9360-6ba437750254">(0038,0064)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5e866c62-2ce5-41dc-aefa-4f2002a98d6f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b2e7b586-8401-4e83-b20a-55aed2eae680">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_70919c5e-37fd-48b9-b603-60a1847a5d0d">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_888dc0a4-50c8-49ff-88b3-17dd7bbe98b2">Issuer of the Container Identifier Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ee1ed44e-cf44-43c6-83ae-407db954c6d4">(0040,0513)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8c1103e3-8c26-4a79-b492-082d32a3052c">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fd7bbedd-a99e-4861-ba89-b7ca6137222b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b34177d0-41f4-4e9e-b4ce-c89fd2d3556d">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_53b69916-d9cc-42e4-9f69-8b101caba95e">Issuer of the Specimen Identifier Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3c99737c-f31f-4ccc-8ca8-4121bfd05524">(0040,0562)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_36d087dc-0e9a-4884-987a-10010b1a4d7a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5f0d1e2c-88f9-4465-9704-d7b6c113827c">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5611c492-9b18-4b76-9b0c-bf03cceb9091">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9374d6e0-6a84-47fb-990c-939ab7f26795">Issue Time of Imaging Service Request</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3f3b09bb-e259-486c-96e3-04361486e93c">(0040,2005)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_37adeb49-5ff3-4348-b50d-06f591ac8673">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bbdde522-ad1f-46f0-95a6-398133d80526">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_840eb464-c393-4adf-be0f-cdbce95c8bb6">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a7efde38-6395-4a60-ad70-960459202c61">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d01ef6ca-e80e-46fe-975e-2d437f4afc9d">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d14e20e2-87a5-45ec-b4bc-d416293e05e5">Label Text</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a3919407-7d93-41a6-a160-e498f6a3aff3">(2200,0002)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_661348fd-1cd3-4b1b-ac32-46a67bd0eac4">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7ea5b438-f0ea-478d-b1f7-8fc092ba6050">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7010548a-f805-4581-b857-4407ff681ea0">X/Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f251edbb-0879-418e-82de-8b921e707767">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2c1e9bb5-0836-4949-91af-0a8e758b8afa">Large Palette Color Lookup Table UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_acc4d47f-6d43-466c-835a-d8ba8656bb35">(0028,1214)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_502de5a9-45cc-425e-b37d-dab11bed035c">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_93f158d6-2f92-4c4f-9678-2e2a37dbca81">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bb1ed6ee-e9ad-47eb-b996-b3db999612a2">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_777b7687-6a31-4818-a3d9-8b1648155d8e">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2aa74cd-064b-4b51-9852-47a73b77a142">Last Menstrual Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_00122ccc-3ded-4df8-b7cb-47486e8fc8e4">(0010,21D0)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d6389346-651c-4179-96ec-d664f54ccbb9">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dc8963cb-43ab-42a8-a9f7-65218fe6cf1f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_da7caee7-9238-4d85-a920-e17d2b040f7e">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a9915ae6-fb98-4d23-a614-5a271b38c9c3">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb5ecad7-01b7-4e4d-9eb8-902a77b15fa6">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac5ee2f7-e047-4e0f-a6a4-a43233d89e54">Lens Make</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf2033c2-a3bc-43c6-9a4d-b8ac696f9593">(0016,004F)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8605d559-19b2-446f-813c-26a240dae169">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e4b56501-ce2d-4504-bcb3-d8d3ce332e60">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_689ef61f-eb31-4c58-80e8-540853a66ead">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ec826da9-fe32-470c-8623-a1f3b0c5af26">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06dbceea-9dad-4ed6-993e-82666e762ff4">Lens Model</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f4bc5809-7ce1-4d35-8f4c-dcaa6a167737">(0016,0050)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c700e1f3-9bcf-404d-96eb-7801ea9dc880">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1510ebe3-392f-4a0d-8828-6070575e1137">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_08416495-1232-4fe7-8943-832d40c3dc9f">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ba66c831-6cc1-4b5c-8220-8519f0a1660d">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba4f53f8-e0a7-4811-ac3d-d4f4fa0c58c9">Lens Serial Number</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d96d9346-156f-49bc-a534-a9978e2183c6">(0016,0051)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1f96afce-472e-415c-b998-7168dff64a49">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8cc866f7-0f91-42dd-89fe-ce61240ed719">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c45911d-4b7f-4de2-b534-4bbdcfe83a4a">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0981fb54-14ce-4103-bc48-069b0340650f">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6087fd8a-cd10-4cbf-8388-66892f4c36a8">Lens Specification</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0cb2b8ab-383b-475d-b534-993df6499aa5">(0016,004E)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_32bca1a0-8246-4f46-b5fe-e412455e19f6">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_df8ba455-3368-4467-a0de-023aed2512b4">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9eba1038-4559-4abf-88c9-1a5d83781bb8">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_422bc94b-847f-4032-933c-95f3fcb5f057">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a87435b5-2dfb-4294-920a-88d1243cdea0">Long Device Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb16f3b9-28e9-495d-8ba2-8ee45fe36975">(0050,0021)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f2cdecbb-e86a-4bd0-9adb-3d9738e4dc77">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_18faf587-03b1-4df5-a9c4-649aef4a999b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3ae40bad-3048-434f-9fdb-4a66de7c6bc7">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4870c4f9-502d-4acb-9911-4b4328058056">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6382aa3e-e294-451e-b140-0b0dbb5f58f9">MAC</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b6251beb-e3d8-4d17-9db8-953f725a256b">(0400,0404)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_36eb30d4-6328-4edd-b4ea-2baf74d00d95">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a2306f10-f2af-476b-99da-ab5bf8d266a2">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b8c5a53-5187-4776-ab36-d094b0023b85">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f080a22b-23cd-459d-85fb-70796b74ae5e">Maker Note</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_215d2237-d7b3-4d51-8cb5-5b0fe8fdc9ae">(0016,002B)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_05b1fbb8-e095-4753-9049-ba1f7e59f43a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5d5e67b6-5f14-43e4-a9e5-ef4c0f0d27fe">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_217d783e-e6d6-464b-8fba-5025db7c0cbf">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7a76dd28-7fdf-4b3e-a185-1e1fce467171">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b8d6659-fef0-4d8f-8d61-81225bc393a2">Manufacturer's Device Class UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5f257738-9e5a-4e83-8bda-9419d5775b4e">(0018,100B)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eaddc3a2-6d24-40a9-bcae-6e0f973fa9b8">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2722469d-38aa-4f4d-b689-76c09bb6d479">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3d8f49a3-7787-4bf5-b847-df2acd0d2cb2">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f3f101e0-f091-4bbd-a5c6-0f6787cdad81">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ce4296c5-6085-45a1-a12c-eab3361de6c9">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e77fd488-4825-406b-971a-51a2b0e36c91">Manufacturer's Device Identifier</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_628cc8eb-e633-49bb-ad99-77238736c59e">(3010,0043)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_965a5b8e-3ac3-4348-8517-232a862a723a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0f6e6437-b49e-495a-899d-fca5dc9205f4">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73ec787d-2e79-42aa-916d-694d61124ede">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b417dd34-5d08-4355-a448-76bd20ee9d8a">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8af074bd-9474-4cf0-9074-446222f0dfe3">Media Storage SOP Instance UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_37ef2a02-2050-472f-ad29-b397f77f93cc">(0002,0003)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4b327d0c-63ff-4b7a-ab24-b2613bda76bd">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cdff87ca-602c-4314-9ab6-798f5d5f843e">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ea92ab46-5ff0-44ff-954b-236a6f8c6df8">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7058e003-128d-4ac4-9d39-ad22cb6cd795">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_970a2193-d19b-4bb1-bef2-b486a458b557">Medical Alerts</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73bd0b8c-17ea-4c71-89ee-367f7ea26c96">(0010,2000)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2ebeabd9-282f-4cd1-9188-ed1f3aed5c02">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9eae1e93-1cbe-42b0-943f-9e81c0719ba3">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_109ef5d9-ecf6-4f2a-aa96-c2b8f8e01429">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bd359a51-03fc-458f-bc63-161bbdabcf62">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf785d57-a483-4df9-a6ed-5254b4e4837c">Medical Record Locator</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aa337c56-683d-4fc5-8fbd-46d270709178">(0010,1090)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_80f6f140-9f25-4f90-8472-1c00074b95da">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bdb39c76-74e8-4f50-bd91-1114248b7318">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9782ae56-a157-4283-b120-a3e7745141af">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e1b6bfa-a945-4a1b-827a-8154d173c948">Military Rank</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_974da8e2-56ef-44ab-90db-2a0c3201eaa0">(0010,1080)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aa1630a2-c6b4-40b0-ac24-aaefee628140">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1aabfe7f-49b5-42a8-bf86-69aa3fca95a4">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0b16ef4f-6d76-433e-b33d-cb4569ad56cc">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24cd2819-47c4-4216-b367-e24870678c75">Modified Attributes Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7d76b4d6-34a4-4988-8968-d15fb6762beb">(0400,0550)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c9752181-07fd-44c5-b57d-cb0661becccc">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7bbe33cd-4d3f-4c1a-832c-072eff2e25ac">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f45c1255-b380-47f5-8729-73a338c22f21">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70ff649e-3511-417f-aede-d9fc00b1a42f">Modified Image Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3c4131dc-8f8a-4bed-8127-ef9041648c97">(0020,3403)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_79949777-ed6f-4916-851c-5bfb078dcc84">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bb262288-b2c3-450d-bccb-863c91a77d18">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f509e0bc-b5ab-473a-b73a-29bc57254752">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_22d9fc1d-beb6-4bfc-aaf7-14ece56a705f">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_99845639-e05a-4177-a220-a89d02d921c5">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_34473c6a-8e4b-4485-be3f-36708e276ca7">Modified Image Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2296e66e-ef1d-4685-966e-15e28392fea2">(0020,3406)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d004aa9b-fc45-47df-9482-9c6d13e44ae6">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bfa4b780-b953-422d-b224-584471611f5b">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_95478c63-9887-4389-9997-718308c9edb0">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_145c2075-d6a6-4450-b0b0-a7f00c68732f">Modified Image Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_98ed0a41-cfd1-4c76-9a18-31f1f3e5c375">(0020,3405)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_097bee5c-c60e-4ba8-932a-cde5def99557">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3c6c73d4-f3c8-4631-85ba-b90168bc2ec3">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b092ecd2-a8d4-4401-8c57-7686cdca013f">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5c90b47c-c270-481d-86b0-e2b6d136cea1">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a3616f71-042c-4d23-920a-de354f056ba6">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_abddc5f8-1408-42ee-b2a9-4bf46d308157">Modifying Device ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_040b5937-6ad3-4d93-a518-cc19ce29a692">(0020,3401)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9464aaa4-5b3f-415b-a4b4-466852cdfaa9">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7aff62df-30ff-47fb-a318-c7b9cc6c5c6d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_49bf1094-a5a7-46ce-8651-2d7fd096646e">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6894482a-82bc-4660-b32a-7accc0021db7">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04b74efd-2db7-4d8a-aad2-c2f5b7a9bc54">Modifying System</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c9e4260a-8def-4c3f-9190-9917c1912e46">(0400,0563)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8baaa48b-aa97-4f0f-85c6-922bd8c15d0c">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_745b83f4-873b-4fa8-9d11-d76593b03f67">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_76bc3551-8540-4750-b376-d47e37c387fa">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a1b2ae32-5f74-4ea9-ba85-8fc6ba860b57">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bab3cdb5-a58b-4905-aa82-8e914548e08e">Montage Channel Label</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_03df77e0-73e3-4c98-9de8-04d3c8f13cf1">(0040,B03F)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_30bfaa66-69b8-450c-b800-1de31138902a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_784697f0-a5ee-4210-9799-04f36fba2f2b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d194f03-1bc1-4357-8c16-bcb8131f4bf5">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_28989225-da4a-4b39-8282-6ab85833e326">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_609e76ef-4b18-4910-9224-aec8442db586">Montage Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a9f7098d-a584-4560-8e69-cb7ed4968f17">(0040,B03B)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_12e1dbe7-2246-4466-8551-4b48699fc76b">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a99822da-2258-42ca-91ef-159ce59cfb80">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6e3bd358-d9e9-46dd-aa51-3857711a1468">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d6213a52-5f0d-4490-93d0-c2fc79d313c7">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3c47d8a-f880-4c63-ae62-c23edcde6dc6">Most Recent Treatment Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1f715088-3567-470f-adff-2622f00b13fd">(3008,0056)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9296dc83-a1ba-4862-92e4-918c9f46ed58">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb1c863e-cec8-4caa-8066-4ac08b29279e">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_181d5022-1e20-44bb-9e54-d671bfe13523">X/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c011109e-7694-47d1-ab11-913ce78fb2d5">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8b1bc129-210f-4738-acfb-0650d239b0e8">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9fde3ed8-708a-49ff-b429-991a31b4776b">Multi-energy Acquisition Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_acc63392-c9a4-4727-8cb8-852e00b616c7">(0018,937B)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5705ca7b-73f8-4d66-847d-85d61a60dab6">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_796ad01e-9e0d-4c2c-af92-68f575a24e8d">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3cf3f520-966e-46db-ab93-72ba96e12258">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1220af88-b556-4f1b-985c-efc715d4d57a">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c9ab5207-5a53-4012-b0ed-e647223a0d7d">Multiplex Group Label</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_65746481-1512-4d36-a26b-577aae0a5f86">(003A,0020)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3278ccc7-9614-4651-8ff2-c991baf35c55">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_08a02d3a-c18c-413d-bd5a-31ce0f029d49">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_515e53ec-6d62-4500-a969-58086d918cdb">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_159e6590-c33b-4b88-8e16-0938a1f6b1ce">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_526bf419-c314-4d22-ac94-08818f36f643">Multiplex Group UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_357f25dd-7294-4a6c-a953-49be740e85e4">(003A,0310)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_19f27621-59ae-40c4-a01c-063760a72f75">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c1d6fd08-d1d4-40df-9bb5-e510ef48ad97">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f2834069-698b-4afc-a395-182bb6c600c3">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_41bf30c6-e88b-4f52-8f4e-1c163aeb8bed">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c78afc9-891f-4d23-9f76-b639d25d7d01">Name of Physician(s) Reading Study</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c9c743a-b9de-4450-ae38-5c011031399c">(0008,1060)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7470e7c1-defc-40da-8452-224cacd481b4">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_21c057b3-48a6-4dd1-a79f-1aad6ec52e53">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7ab2839f-50b4-43f4-a791-3b29d242d1e8">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a26e54f3-31d1-4423-8938-df154701097b">Names of Intended Recipients of Results</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5536590a-4a18-45bc-b24a-bc0114d04841">(0040,1010)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_88c75304-3d18-4d01-866a-0b1defa249cf">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_397a6066-e376-4ec2-95bc-d53a8af95574">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d52c63db-10bb-457c-af6e-154b840444d9">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c3b2a568-8c2d-42e6-aff4-f00939930484">Name to Use</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2b7d830d-bd4d-4457-b048-0d7ddcbfea62">(0010,0012)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0e541c6f-673e-4377-8a4e-0c05739df350">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc8887df-5252-4673-9b2d-fd5c618dfb9b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ef644511-5a61-495c-813e-4f3e19c36245">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b026fd85-4908-459b-a43a-794a71b44b5e">Name to Use Comment</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_33b18d6a-516a-4fac-8b8a-2d8d77aea5ff">(0010,0013)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fe7cb216-2b42-4260-aab1-49401c83f977">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4cd2cb7f-1cce-433c-afbc-9088db55de0a">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_75381c7c-5b4f-4596-8af3-649e4c43f0b9">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4724cf35-c601-428d-b20b-3d988dbcd9b2">Network ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5f5ba42b-f40f-4d87-af27-03662903828f">(0008,1000)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_90fec0ca-90de-4fcc-9707-9265782d3138">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5d1fef8a-d5f0-475d-bbef-9b07fce229c4">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3f207ceb-c53e-437c-9604-cce942e04ba7">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d066d588-4bd7-4e43-a2e3-a66970671892">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b756aa8f-7248-42bf-aced-f7a5cf1a742c">Nonconforming Data Element Value</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b50bbb97-6a87-4ed5-ba53-1fdedf627b38">(0400,0552)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3b20eaa4-8e59-4b71-9b59-e4b70a5be52b">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7156c090-61c9-42cc-aba8-5086394bd17e">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a9842d0b-7f4a-4710-b616-097c323ba90b">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b343316-5a24-45ea-a84b-945d552937ec">Nonconforming Modified Attributes Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e609a257-aeb2-4bff-ad59-daf4ae7ef3b8">(0400,0551)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5e3dd4bc-7772-462b-aefc-93a672d9c681">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dc7aaa87-1da0-4643-a190-f9cab99af48a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_59eb2307-30e1-4b19-b7ab-287a44c7a9d2">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_598520e6-678a-42a2-828e-4b5d7b33bb70">Observation Date (Trial)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_42bfecd1-5e27-40d7-b05c-eb1d24779213">(0040,A192)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e8cff258-2288-4ff5-bd6b-81e5dd4bafd0">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9f405aa8-705c-4231-b917-049554e9c3f3">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a82cd862-1caf-4e7d-ad1d-e7e70842e9e1">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_28701deb-fcf4-4614-b75d-820de400521d">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ed8ffb7b-a838-42fa-9ae9-b21b9f2b2aa8">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed1b716a-fda5-47cf-a00b-78d07baaf2d7">Observation DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85b321ee-a0cf-4e21-b9dc-3d17611106c1">(0040,A032)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e63f4d6d-d24a-4d55-8e9f-3ce66ea86c45">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ab0c553f-28b7-43c7-baf9-98eae93ecc6c">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_47061c4f-83fa-4843-91de-f3032db2a2ef">X/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_00c2b774-e15a-4402-afa5-421b406afb6a">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_25585851-259d-4be6-9235-65ba9da5a02d">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e3e935e-ce9e-4bbe-8d99-b51f0b78475c">Observation Start DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6d687509-e11b-4265-9f96-1ec4cda1d256">(0040,A033)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6b4260da-fb23-4f30-a03b-9fbc81763ee8">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5c79f105-bbca-4741-9fea-c2bcf1d10233">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_221c67c4-af86-45e1-b9b9-eb4e5bfc41ff">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_77375378-84e4-4ea1-a0d2-fe54d45a640e">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_78e2bd49-3303-4b92-8569-12f2ed7afa84">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_76839773-df6b-4a22-b877-5e9846efedc2">Observation Subject UID (Trial)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bb26a1dc-74ef-4814-856c-1d10637b6e3a">(0040,A402)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fdbc287f-6ceb-4b68-9a1a-655f6a6efaa8">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_80e18184-aa97-4939-bb90-24ad0897f07f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3e07b122-8bf2-450f-84a3-5a6345bb7d8f">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f01bb0e9-3d29-4d0b-bdf9-bb906ba84ec0">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3be0df16-f783-454f-aa3c-b9dac7a32fbf">Observation Time (Trial)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0bd0f502-1b4b-48bb-9695-73b159e28892">(0040,A193)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a4f46446-9071-4850-9a5d-014f67d1a257">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6fbb211f-fc93-4f8c-a9ec-c76735082cb4">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_44428259-84f9-42ec-a64c-3f00e95177f5">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_121c406e-e90a-4127-bce6-f49a1bdbdab6">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_157fadec-c675-4d3a-b470-976fa6d58af4">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_89892cf1-db50-434a-b207-76e912a31781">Observation UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8b833512-6a40-48f8-905f-b13a7ad0c306">(0040,A171)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bce0a51f-05c2-4078-a190-cffb554a1993">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c38117b7-099e-4879-a14b-00f6968e24fd">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_35915289-351f-43be-a6f1-d168100e7869">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b1375a1b-6341-422f-b8c6-64e55206539b">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c77a4584-e7fc-488e-818a-2e8ff1138745">Occupation</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69ba6e33-3aa6-4352-9e78-044c4c90eb7d">(0010,2180)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7bf3039e-7790-49f8-8d70-4e886ad8406c">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dc41c479-3678-4725-a916-a1acc503aed7">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cfaf07a7-16e7-48e5-9db8-d99870a03d41">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_90476987-2d55-45bb-80e9-cce0a0f11ca1">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e566ea7-8d8a-4554-b5c2-0cf832e58088">Operator Identification Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_306645c9-1069-424d-92b3-0d2625489228">(0008,1072)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_14b630f7-d349-494d-b396-3ec615d1ae33">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4aebc4fb-a574-4f16-9c98-1272fc1f28ef">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4856309a-b948-4d45-86b9-14f856b074d2">X/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b7dc4a6-ddec-4c82-9960-069a0328b59d">Operators' Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9feb22cf-5914-458c-9a68-a0a96cdf4354">(0008,1070)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_44c8fc8a-f464-4e54-8032-1d2bc73c0d9e">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_42c28fee-7a00-421a-9a9e-76c0879a3795">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2a5a5a11-ddd2-4917-8ea4-faeacd72b0ba">X/Z/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_489b0652-b973-432d-914c-afc10fd688cf">Order Callback Phone Number</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_35a071aa-c15a-4c8a-8b6f-49aa86800cde">(0040,2010)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e8a507dd-f103-4430-8a16-653a662b07cf">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b3e639d4-091d-4a2e-ab00-a8af3cfc047f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_13246528-32d3-4962-be1d-6c572df880d3">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ced3e90-aafa-4d89-93ec-ef2f33723eb3">Order Callback Telecom Information</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2eeaba89-8e43-4c01-b1a2-b4ec5b4e077a">(0040,2011)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_231fcd81-9110-4a57-88f2-1900d9cd3086">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_17a2393f-9e8b-4952-9a2a-7adb7a68fa2a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d7cd60b1-3a22-44f2-a436-9686688eca7f">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8bfeead-b807-40b1-b36d-9d5114f04249">Order Entered By</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_edc7b7ad-8604-4fe6-9f4e-35b77163b0f6">(0040,2008)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_77609ae5-21c3-4dcc-b325-5025d26b8911">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_557623a2-ee84-4cc8-a803-19bdf2a51837">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73cbd85a-7db3-4354-8987-1d35e1f3d653">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5c0ccb70-35cd-473d-8d59-feb0ac66c9bd">Order Enterer's Location</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d72f6142-8522-40a9-878c-62d518990eb7">(0040,2009)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_96002853-c694-440f-8e5a-a48a4e32d496">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a13a7442-fe99-4b1e-8071-297752660079">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f0b4e14-faa5-4b4c-aa1f-cd1992a6872b">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d242af9-7e08-47fb-b0dd-464023dd4472">Original Attributes Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_45818a5e-4c16-4750-bbdc-d01ea88736eb">(0400,0561)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9c76097a-97f0-42ba-90b2-c10cc1d4eb27">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69be2f25-1ba6-4e88-af6f-bae1de39f62c">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2643f001-70d6-4a84-88bb-f9df96ea898f">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1177b45-2372-4b1c-ab8e-ad06bb5c9449">Originator</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_abca12bc-9ade-4963-8cc7-e591e1f4571a">(2100,0070)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e66184df-1fa5-4fbf-857f-a54bc523e7da">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1bbf8cae-5908-46d7-9742-aa0e5f92ca66">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2e7deffa-0b16-4060-9b81-37fad8fa99ed">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e777e801-01da-4551-942a-a568cd359f6f">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99317574-a3f8-41f6-b96b-216d279d4b2f">Other Clinical Trial Protocol IDs Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f70e90b-8322-470b-a75b-5327fd011a8c">(0012,0023)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_36bea22b-9c71-42ec-b12a-8257d296e929">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3cd2bedb-bc2a-4cf6-82ae-fb182225960c">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5d55c208-896b-49fc-9f3f-1d6a6c224f53">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_baa8316d-5a61-4409-963c-3070128d19e4">Other Patient IDs</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d1f5a17a-906c-4de0-a2d2-6c9f15f07ae5">(0010,1000)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b1d1b94c-8b64-4f2d-ab81-f6865b7a8dfc">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b793dd8e-77a0-44d6-bf28-aa4ed1a91aa2">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_92ed4962-5dc2-48f4-9b3a-8b9db770b266">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9556d372-54bf-40ff-97b4-38deff5b0e34">Other Patient IDs Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ad8295f-c3b9-4584-9f45-ffd208a3b958">(0010,1002)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_526df799-2069-451c-93ce-dcf1a563778b">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7c4aeb8f-6d0d-4dae-bcac-16afb0984da5">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_59d23e05-ff97-448e-851d-a8bee30fc13c">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c9ccaefb-209b-48cc-bc65-54c85bc85745">Other Patient Names</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5499ba06-b72a-4e5d-bd94-39ea6f97bb0f">(0010,1001)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5a3c8b64-c137-4052-b47a-f7106ff212d5">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_89330b21-10bc-4c37-8320-49f8f99f6d10">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9027d274-1f24-4008-ae03-7a8fe34d0b66">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_472296eb-9bd2-48cc-9067-ad59dba651fb">Overlay Comments</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_23665d62-8cc2-40c4-89f1-3c9a9fd2f5a9">(60xx,4000)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3a554f83-8605-46e7-ad3a-4690abeeabf3">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_47fda22b-0d86-4e2d-96fb-7d866bfb2a56">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f74bdcd0-5b32-48e2-8317-88f470e820c3">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a8c2fc31-ae51-4c82-a06e-49285e536691">C</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1eb760a-388c-4876-837c-a03857f66101">Overlay Data</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b6cb3298-e6b3-4ff0-9dd9-54582d98c95b">(60xx,3000)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_976237a3-f973-40c9-84a3-1a412d208a87">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_27960f59-46d3-4b78-bc78-18ffa671bd4e">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a10bdbb2-b710-47da-81ee-573b0d110999">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_233aa2c9-a162-4d70-a6c8-9cfed6861f92">C</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7552b9a-d892-491e-8e49-da7b809e913c">Overlay Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc80aab6-5306-40d7-8a4b-23d8e951c293">(0008,0024)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ebc45bda-5bdd-4b7b-b0f5-cebd5475dd56">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f61086b-e17d-4fbc-8e9c-2ab36760d8bc">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5304c56b-20f5-46cc-bf80-32415b477838">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a6dce781-b1bd-4204-bc3a-0edbc591cfc1">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb14fe2b-b78c-4230-b1c1-34c49b13e28b">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57c9a397-0c06-4b8c-9fb4-e1b90c710db4">Overlay Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d5d54b5f-effc-4f75-aee1-48bbb8f968ba">(0008,0034)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_90353536-7364-435e-a5f6-bfd55781d3fe">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_415395e9-6041-4a25-b743-5c1409cc8093">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_98825bf9-dc0b-4717-9d54-2ea49f3655ec">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c2683c7c-f434-45d7-b18c-8cfb89e7f00b">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_04b1faef-29db-4b0b-8808-d4f2f8effa97">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11021bef-af60-45b0-bd6c-d374ab499aec">Override DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ffe9e116-a274-451f-85c6-e81a54889ea4">(300A,0760)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5a7e4493-57a0-43b3-ae10-2cfcea296930">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c47195e7-7c0b-4810-b59e-33644a7605d3">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5de5dedc-a801-4c63-866e-a4f11e62dd14">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4bf2f878-9c77-46e6-a16f-c19887293fea">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bde197fe-b9b3-4d68-ba0f-2427845cda91">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b16c838d-adb9-415e-adae-4a54a6e1bd40">Palette Color Lookup Table UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_29f2698e-724e-4b44-88af-cd5a21664e15">(0028,1199)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_71a935e5-dd88-4934-a2f4-ca96876d5884">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f4d03e59-7262-4d8a-882a-3ec8b9020908">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aa164358-840f-44f2-9480-ca10194ff83b">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e8316ae0-8a14-4763-b598-98c02e0ab478">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_659d9962-29b3-4101-ac4e-4f490e95c884">Participant Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c93bc71d-218f-45f2-9f5f-ae3affcdfa5f">(0040,A07A)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_821cab17-7d6a-4db4-afcc-0332dfbe5b7b">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_91237007-6b25-4a5b-870e-3e55aecfc976">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_580aad66-69a8-4a2c-965b-ce4f4e1b8eaa">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2164d6ba-8749-4522-9636-acee6a8055be">Participation DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0b2b999e-cf24-4dd0-8c75-0f2deeadaff1">(0040,A082)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_002a65e9-3ad3-4fcb-8235-a17ac2c0f225">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aa2c3b13-294e-4083-9c55-b9b0a5f0b4a7">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5df81d3f-7342-45de-8d81-c91fec57fb1e">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_72d88a33-3110-45b3-b0ce-716d7fcbc74c">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f23792f1-622b-4da0-b090-6dbbf96d8885">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96c7ca6d-fdc7-4fe6-943d-eb59af94f4f0">Patient's Address</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f2698779-a55c-406d-8118-29973d836e52">(0010,1040)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9caa8b9f-9556-4502-a617-264fccb0321d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b2567180-d930-41ec-88a6-40fdca478e29">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e2807b8d-27f8-4926-bd59-e915c1b595fa">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13f58c3d-04f6-4a76-b601-bc07d480ad96">Patient's Age</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ab649dda-988d-4eb5-9891-3f1342770ea8">(0010,1010)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_710a9468-485d-460c-a5ce-e12cd5502843">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5e1112db-6094-4a1b-8d5c-cebd42df7f88">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a04b90cf-f038-4474-8c7f-63b983457916">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5819908f-97aa-4c6f-a2ef-5694e4d22801">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5cb79883-16e6-404a-8303-c46db8c256fe">Patient's Birth Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e6acb2ab-9e54-42ca-b111-17427493b13e">(0010,0030)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_968ad14f-e174-446b-897f-f8c49ed1f03c">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cac13512-107d-466f-9be5-b89e17400145">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_65aac79e-eec8-4e45-9817-6a7352342802">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_41be54f0-14b5-40e7-9975-be442a1f4f31">Patient's Birth Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_164fc930-c917-46ce-9582-a8847b9e3b77">(0010,1005)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1a4d0a93-5952-4781-a382-f823aa5c7f91">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ffe2bee4-ae84-4bca-a1cf-493edc07d336">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ea0ba47a-d888-40da-ae99-e6df02238eb4">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d224b7ab-8b6f-4798-ba6a-13b065ecd7a1">Patient's Birth Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_64c2f51c-ba43-4f67-b273-700d6421fc4f">(0010,0032)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0281b072-3a45-44c5-88b3-1a23a7075c04">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d1a6fc32-9f22-4e03-88e4-d1472cd3b030">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f06462aa-5387-44b7-833e-5692df29a7e8">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df2dee5f-808d-4d6a-9129-c6ff50cb9cbf">Patient's Institution Residence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf673034-8be9-44cc-bf69-dc4ad8b3ec84">(0038,0400)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d5797b17-b1e6-4df6-b9c1-2031a39fa248">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6bb04a33-410b-4b28-8047-099ec2d986f0">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2e4c3465-2022-427a-8aa6-a13f933efcc0">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6526474c-01fc-42be-8ef0-42dabf05e800">Patient's Insurance Plan Code Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b81fcec5-a200-48dd-87ed-6be14d756f95">(0010,0050)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cd0ca444-028c-4cee-8fd7-1cd99dec4050">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_87637802-4f62-4527-8433-44246749b542">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_20c940a2-f82b-4e40-8c06-bc3876e580c8">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ab10c4e-72b6-4f13-bbdb-460db8ec562c">Patient's Mother's Birth Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f69fe31-2651-469d-9b68-bae1d620f52b">(0010,1060)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ada9f6cc-7a26-4af5-8b9d-fb510dc72de6">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7f8e02cf-5240-4341-bbcd-8cf9fbb5d1aa">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6bf83b29-5554-4f1d-924c-fbec7ca5a036">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3fee6515-cca5-4105-9ae4-3cd0c9b824a6">Patient's Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ca7160b3-a8c4-4169-bea8-f5ffc7eec4d4">(0010,0010)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_29c4757a-fc55-445a-afd3-1324a5d7b56e">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2cbca89f-59b1-4e0a-b844-47ba1fd81cc4">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_135056ca-7391-4a09-8ad1-8c82caec489f">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a1e2c26-71f7-434b-8c55-8d57b88093f0">Patient's Primary Language Code Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a847dd29-7727-4fdd-b1ec-ce066645e745">(0010,0101)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_370a5c40-3780-4004-aa03-f7cc4119601c">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9570aab8-1836-483f-9877-e23ddffc1c3e">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c1b1b5f8-6351-40a0-b074-33ffbea7b5d2">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1085b037-3375-4b3f-b8b1-10e63323c96c">Patient's Primary Language Modifier Code Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_51bfac38-8c2d-4558-bb24-9f77fcd63936">(0010,0102)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2587da6a-80ca-4eba-80bf-d57250c96b04">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_34db69ba-526a-4a06-bf23-8165d2e4c675">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f44a373a-4c11-4be4-acc3-029c845afef3">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35c5d132-394a-4e5a-9ea5-7eefbe2b71d9">Patient's Religious Preference</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ccc40c5c-aa59-4670-bc22-e35cfb5e432b">(0010,21F0)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f9851b7-0b56-4032-955c-cbc90a5f58cd">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7401d133-0748-427d-8fd5-9f2ee4c9037b">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0195793d-5233-45ea-aaed-0b2de6179290">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f571fbd2-c322-4865-9387-6edc04444284">Patient's Sex</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5d2412cc-419b-45f4-8874-a0c8899df38d">(0010,0040)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0bf082f1-2126-4112-b3c6-c5a42c0be7fb">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_741f615c-710c-4e39-91f9-c075de9978c2">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_23f8a9dc-2e05-4ac0-91f2-7c4c7f506e07">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f47066ad-0f5b-4a3c-a927-a012885d0ff2">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d7406e3-3222-413f-8a26-2300ce385d5a">Patient's Sex Neutered</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_98595183-5b10-41b1-aed4-a86a8f6b2a8e">(0010,2203)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7d042a55-728f-48ed-9006-6e58d7a3bec6">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_33709cc8-5f82-4ac7-b72e-4f5fea24b8b5">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_59b0b170-b493-4e70-9295-551ab9b1add6">X/Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7d4c445c-fc9f-4110-a2e6-44a3dafa2029">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_78cb78fe-4bf3-4df5-a42c-8087f352f64a">Patient's Size</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6165a274-232d-4082-8bbd-212c8740628d">(0010,1020)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_36e685fb-4e59-4b6d-9c18-de448f03e9ac">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8c95c96c-7d84-4bcb-a086-e09c8f0f0b02">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a82fd512-6610-4e34-a25b-cbc4a0e49e2f">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_12f79e4b-85b1-45a2-9297-3588c1a13f33">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ad2b252-3230-4374-ab00-29bb028d2d8f">Patient's Telecom Information</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0df28aed-c192-4dd4-adc6-5b8d6c164410">(0010,2155)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_24cb02a3-d21e-44aa-be18-1df2d1f548b0">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7ef5ac2a-27a1-4f04-9689-b9a76be33092">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b2e89a00-e6cf-4d1a-8a52-e7d4b05d6bf0">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd98fb71-5265-48f9-b6c6-7c404349ee34">Patient's Telephone Numbers</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dc025e81-df24-4acc-898d-0ffb48c9bc1f">(0010,2154)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_abda45d1-7744-4ffe-a017-d8e8494f4434">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f6622a88-2b70-4c55-b1dc-dd2b025ae761">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7a9fce0c-6495-4946-9ca3-8ec7ca94c2ad">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_721c7ebc-7fca-46fe-9c80-e9bdd3ac078e">Patient's Weight</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b3b2b8c4-c57e-429e-ac0b-b97fcf491432">(0010,1030)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_15cbae22-30dc-46c2-89f4-cf4af810545b">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b928ab65-8617-4aad-93d2-e056258aaa8a">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e8d5de53-efd6-4270-a0cd-cbd6d7ac2e9a">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_97c5a282-7fe3-4ae1-9fdf-77b57fa68189">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7dfcb567-143c-4f2c-95a7-c10a63c9f448">Patient Comments</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_da325d09-38c6-413c-84e9-605e6d4bd4cc">(0010,4000)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e690bdd8-1e7c-44dd-849b-5960baced0d5">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4eba872a-1a43-4261-9ed3-c92575dfede6">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4229f400-8dcb-412e-94e5-53b6bdb67fd4">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6755e549-089d-48ad-8db7-edbbc098e3f2">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_664a76d7-247b-4f8c-b67a-34b7a25a878e">Patient ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bd88cabd-f641-43ff-afc5-15a5cbd461f3">(0010,0020)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_29814101-99be-41aa-9313-944692015b0e">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e6e70d37-682e-4b2b-a98f-cf3f796c2133">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9f41381d-464d-4fee-8182-2d986ea634e6">Z/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0d53e10-11bb-43da-a36e-ef39a53bbf5a">Patient Setup Photo Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3282392c-fbf0-4db7-80a1-35b2be606a8a">(300A,0794)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1c87feb1-b638-4adc-bcd7-b0076305f69b">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c3ed3c40-7098-4093-8782-8466d3d634c9">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_68d23828-a771-4d41-b038-66d792162728">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d01321df-1ac4-43d1-94a4-81e358a1a145">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac3898d3-bea2-4195-9d77-adeb5cf386f0">Patient Setup UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_603e4516-11aa-4059-baa3-3277e767ed75">(300A,0650)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d54828d-1423-45c6-8b25-7ce6076b4a21">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ee8df3cc-de75-4074-9dfb-25f1bc85365f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_11cdc87d-6343-4546-92b1-6249d3998dd6">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a61f8712-6095-4c39-aa6e-390e073b75eb">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82293ae1-41e3-4a19-b6e0-86ce515f3dd2">Patient State</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69e6a019-3bba-4eba-a3c3-37fc34e507a8">(0038,0500)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ca1950a5-5601-45eb-bc3f-d78b1bbb6192">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cc81fca1-26c9-47a3-a322-faf7fa578a89">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4de70d3b-efb4-4ca2-bf16-e3074f0abd0f">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0669a1da-a80d-4dc8-b075-1695012d4a93">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9174fc7e-df35-4144-b0d5-bbd9a16df21a">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f7eaea2-5ca3-414b-9eb3-a357d3bd19f6">Patient Transport Arrangements</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6d91eaf6-cd38-47af-8c31-426b9c87ec1f">(0040,1004)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_102f914d-dd6b-4b85-9d17-804af99421e0">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c8e61dcf-d386-46c4-b963-1c81f48dd2f3">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a33c1c1e-a21b-41f6-b154-70b3099ed6c6">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1ce149a-358a-4970-a26a-1b0e81d27d3c">Patient Treatment Preparation Method Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a4f7ab87-cdf3-430c-83fa-1150ee3862d1">(300A,0792)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d60af678-10fe-4b1d-abca-06c551a23a1c">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fc1ea908-06a1-4458-845b-e7049f513167">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_144a8bfb-bb76-4b14-9a23-bb731edb7559">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f5122b09-666b-4543-95cb-bba2a01934b1">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d66bfc7-b19d-4c48-86c7-2335fae1235d">Patient Treatment Preparation Procedure Parameter Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9778aa40-bd11-40b6-acae-a67f9ff68750">(300A,078E)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_43ff6463-d8d0-4096-a78d-983ef11dd078">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f757cf74-a30f-465d-b692-7a9a05a9efbc">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9d156e57-1621-4a1a-bea3-6f2df95f1d80">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_75eea3da-098f-481e-b651-71551f796ccb">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_702150af-7849-4e3d-b364-16b175b19a79">Performed Location</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a0d1b0b0-4001-4cd0-a345-c04cf29137e1">(0040,0243)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_df612152-92dd-4d02-8c78-0cd86ce65d64">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ba24c3b2-35bb-4cd9-ba71-fb220d34bfe3">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_65e6fc18-8604-4bcd-97c8-630a649d6a21">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27a20d18-a532-4534-a0a1-4ccb7169769a">Performed Procedure Step Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_908ae34f-eca2-40ac-9448-353f2486bceb">(0040,0254)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1d295ce7-f826-40fb-88c8-6dcf00abdc37">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_314a4505-9988-4388-b9cb-11c94cee8c3c">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7ece95c9-8540-4d27-8a30-e741b8a30090">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c3968b3a-8a52-4ef5-9f10-2af96f712d40">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f443be9-70be-4d7f-87e7-efc08ba1545f">Performed Procedure Step End Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_991e0ab4-426b-49cb-95a7-969d6a66799e">(0040,0250)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_16d4fc42-f72e-4326-9775-b5f965652782">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a7d354d8-0918-429b-9c1a-b3dae69c3ff4">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eb7f2d53-4ff3-4386-8ab9-a0ed46c75425">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ccfa1eb7-b23c-4f1c-9819-52767693cc9b">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cde30f24-b0c7-4964-a3a4-b6dc45ba19d6">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_914c160a-d4ae-4796-b326-4702dc12d891">Performed Procedure Step End DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_055c238d-2516-47b0-86b9-84b6fd564f68">(0040,4051)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7892819c-9ec0-44e2-a504-4738750bd805">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_68de4b9f-a517-406b-ac8d-e7379d7dec4e">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_44ef4766-0bcd-44e9-9315-2537a4677542">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a2225da5-0190-43af-8556-7e4b6800472b">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_29022661-0c3a-4d0d-a1a7-a0462e0b5485">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b5d113b-82f7-4b95-aae8-c10dfd92cb8b">Performed Procedure Step End Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2efc516e-17c2-4bd0-984f-bebae6145239">(0040,0251)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb7e4759-3e22-40e5-aff7-996f5c1da510">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_86fbc104-822e-41cc-99ee-cbfb91d9c316">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9003b36e-efe2-4086-b606-79d04b80c091">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2d5b3618-3b45-449e-a38d-f20ab0781ef4">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_55fc7900-cb26-4160-9f5f-a4017641c424">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ddcc2d2b-601c-4b4d-a310-956c3d341e4d">Performed Procedure Step ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_64aed264-4748-4d79-8e79-68d8f2c06638">(0040,0253)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a93df7c0-9a74-4439-ae6e-59a66da51f3f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ee0e1b0a-da2d-4561-945a-4fde87062830">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d6a36ad9-164e-42d0-a03a-89128be6b3ed">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3aa1e1e8-007b-443e-bb84-ebe2add60134">Performed Procedure Step Start Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9fce19f3-3875-457d-af65-ac3448b65d27">(0040,0244)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_921c6415-9f0e-48f4-ac26-f901d3526a11">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3ab11a1f-8342-47e4-a306-f989524424fe">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ba6dd0b6-ac34-41b7-92a3-fec980d45962">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fe92fa97-926c-4b57-96a5-94e32b73a0e0">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3100d817-4bfd-4211-900c-a11a15288885">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d26c1c8-7b43-4e7b-aae1-ccd0cfa3568a">Performed Procedure Step Start DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e8556d3a-f1aa-435f-9998-1f9ec0d9f1a0">(0040,4050)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3684cbc9-f7f9-4577-a421-eb0e6b016908">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1696300f-29ee-4e1c-bfe3-ccb00d1745f2">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_908151d6-44d4-4888-ae12-4ddb70a8b3ac">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_830e5187-0965-4080-96c1-bfb27e63f0d6">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_92ef4898-bf74-4f12-8719-7cd814281cb2">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5e96434-5d98-4a95-b885-9e44a2732057">Performed Procedure Step Start Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4be8ca7b-2981-402f-a831-26dcf3390f9d">(0040,0245)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c4f7372e-df05-4e17-984a-230553f788c4">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ac0e489d-f985-48fb-ae08-a58ce7d174d1">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c51c9548-6161-4c39-bddd-ea30a0bcd6f1">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ff56834a-8b0c-494c-8595-8f2b45977e18">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_691f1679-276c-4704-bb7b-ac37125b188a">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10af9e2f-9eda-4cc1-8133-223e334f030d">Performed Station AE Title</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1692f3bb-306e-4b27-a963-79b4663727a6">(0040,0241)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_62c2034d-7ddf-4b21-b011-cbb16d99c977">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_415b1592-9b12-433c-abcd-d9eccb76fdf8">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3f446a2a-24fa-4527-b3bf-3f2886eefd55">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_31d3dd71-ea88-482b-a319-769ea1934686">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d6315b92-c6b8-44eb-afcb-1aff48d24287">Performed Station Geographic Location Code Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ea97dfc-aaef-495f-9d47-a6b07e31e317">(0040,4030)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_75464ecc-87b2-44eb-9c74-9c47e20b2ad5">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ef07bc2e-8dc0-43e4-8727-e411242a32b0">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2946ed41-7ea9-4df5-9b8e-67beee94cf94">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b0e0ed49-9525-4257-830b-d5fad6d44161">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b9010ae1-7e78-470d-9fba-a23db6e3934f">Performed Station Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ac385a68-d655-453c-982c-b0ca8dc51963">(0040,0242)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0e676ba2-1f3a-4a5d-900d-0037083b31f4">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0cc61362-7626-4465-911c-56e4d33b7ec1">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e578fb27-05e4-4e8c-a138-99e0f49393ce">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8e51728e-0f9f-4ab2-87f6-78df3e8dedfb">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3b213cd-47b5-40e6-ab91-d69b3ee339a1">Performed Station Name Code Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_16a1bf08-6c77-45f9-966b-d2d22b847c51">(0040,4028)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e8b27a05-a048-4cd8-afcc-bda1a9ea5a55">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc32c45d-3f93-4b01-b8e4-b04b89d2272b">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b6508339-bc4b-4e0c-817f-899f972fa69b">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6d0bd4d1-f75e-4fd5-8dd6-860ac5cedf29">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a507b0b0-1969-4a7b-ba55-31ce0ce7056e">Performing Physician's Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a0aff0e8-3af0-496f-940d-c19911b1ae6b">(0008,1050)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_10ae7d37-9373-47c0-9320-86fccd401dd2">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_23062fb1-6c1f-43bd-9c16-0ecea8a21798">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c332d824-7afb-4d22-b4f8-caac5efaadc6">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d670f8c-a8eb-4f58-8344-a586071a981b">Performing Physician Identification Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a3f3bd0a-b035-47f4-83bf-e9f95944bcd7">(0008,1052)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1c2d771e-f990-484b-b159-cc432589efa1">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_53fb2d2c-0bbf-425b-bb3f-0f3033eea880">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1d757a68-510c-4c85-82ca-f2872896a7be">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3624bbee-46bb-4ceb-a0e5-9df78a754b55">Person's Address</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_175e3d2b-2740-444e-94b6-ab0056df2b1a">(0040,1102)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f2b62e2d-f861-49ee-a6a7-491abb4c3126">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_468146a5-92f2-4fe4-aef1-29f4e908a7e6">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_32403bda-5f38-4204-8af2-80d0d1471151">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_017e7060-792d-4c6b-b4d7-fb12c834e5bb">Person's Telecom Information</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_48971490-8e3f-4a13-81e1-2978be436cc9">(0040,1104)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_adeb00a7-9965-476b-841d-b91fc5f71dbb">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8959d74b-c4b2-4a41-a15b-1d7d49b298d3">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eb3c88ff-1b67-4ed2-8a6e-ce88436cc895">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0d1a1ce-b66e-4c7f-a677-2bbd384be622">Person's Telephone Numbers</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c14d130b-fdcd-403c-bc9e-c8adcab9ee74">(0040,1103)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fad342fb-4232-4120-bc55-78820dace541">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3b5d1fd1-e7dd-4132-9ae0-ca61e678c786">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bd5ac7b5-7785-4d49-ae4c-0ebbaf3d31e0">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43ce881a-795e-4082-9b4d-5829be1a7c34">Person Identification Code Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d2dc7d6e-1cf8-4258-a8f1-8f0bd687b775">(0040,1101)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_41371ae5-7868-4267-b510-cb821fb0b769">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ec86451a-7245-4412-b8f5-e0b8e05a93c3">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d94a8f27-fd3a-48fb-8089-d2e7ded25092">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f10f7c8-2d5a-44f1-9908-09bb893dddd5">Person Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8cd38a9a-f29a-4b05-b676-58d162e661c0">(0040,A123)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_862a72bb-5baa-4d81-81cd-dea6ba077a84">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f60446ef-5705-4f4e-a978-26d134b0d5b2">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bab0f1e9-bf0c-4620-932d-d0f2ac974337">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7868bcb3-e5a9-42cd-ae8d-a98fea57e6ca">Person Names to Use Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_df23b848-0bf2-422e-8731-020fd32b4802">(0010,0011)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_78bb5fa1-2cf1-4c69-947d-8aa4ce2840c4">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4c0a4a7e-4742-4687-80fc-00405b2dd817">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f99e6d1-8ac7-4ff1-b861-a4fe63be86bb">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff5f44fe-13b6-486d-9b79-2caf0660512e">Physician(s) of Record</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0cf7b6b5-5cc6-4003-9ffa-e573d5d0e146">(0008,1048)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_47d6af9c-369f-49f5-b12d-4e5bc4447fd6">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0ae730e2-3efd-4780-af32-4429efcd2ec0">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2031e91f-7ad9-4aef-a6aa-786a75f8e619">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dabac6bd-60eb-4a01-a4db-daccc962b582">Physician(s) of Record Identification Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2c442192-dc77-4097-84e8-3be4343adf2d">(0008,1049)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_90bcd817-3d78-4b04-a0b5-5bc3a9d3584d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7a0b421a-b876-4951-a024-295d9e4990a7">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_062ae11c-4cc0-4185-9935-a25871ff9d39">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70d054a0-2e77-4977-8329-defe9cb46dff">Physician(s) Reading Study Identification Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d3c72232-3778-42f7-ba6a-27e4a4b049fb">(0008,1062)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_836016e2-1298-4cab-8d60-68f48a80442f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_52c8b8af-5e7c-41a9-8301-567676137d0e">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8de2f607-4c26-4be1-a017-c00306350eba">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bbcee83e-14f0-4b12-ba6b-f5c945ff7306">Physician Approving Interpretation</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ab678b02-18c0-4beb-903c-f4abf7b61bfd">(4008,0114)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_db2e5814-4f2f-4680-953d-86181aff0e92">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_33118021-b5fb-4161-833d-d73d65bc7bc5">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e799e3ea-76b2-44a7-a8dd-28039c614d7f">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ae65d29-1368-470c-9f43-bf663556ba6b">Placer Order Number / Imaging Service Request</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f1282f6-a07d-44b8-a902-b2d3de262c98">(0040,2016)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_217d81fc-85fe-4362-bdc1-72d33deb5677">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ce156e74-bb71-4caa-9f7a-89893bbf4fc4">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0d3c6668-3861-4a7c-8b33-3078da2587bb">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54048b99-d6b8-4a36-ac70-e0ad756b63ad">Plate ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_72a8be75-12b8-49bd-ab20-6991874908e9">(0018,1004)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8c23a59f-ab83-409e-bf9e-98483932ee5f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3ac3e38e-b881-4657-a326-950d929f8771">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f66e4870-29f7-42d9-82d4-6ae18b0c46f3">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_427eb9ad-2d0a-4921-b83c-d24c63b428e2">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff74d1e0-9307-48da-b7e7-30c7fee99e3f">Position Acquisition Template Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a04b975-35cc-43c7-a714-511aa50a797d">(3002,0123)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cc6540ce-9b38-46f9-8d6d-eaa4de727a5e">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a8005dd7-8585-4ea9-9d25-67b47f088acc">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_144210d1-8142-447e-a775-5daaef4beea5">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc20185a-60ae-49b3-a91e-2a786522cf4d">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6c0fb628-bbce-4f2a-b313-d554f559cb85">Position Acquisition Template Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_630d89e4-63f4-40d5-9625-e02a60ccdf88">(3002,0121)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fa97c4ec-0b6a-4797-97d6-5dc61d93b5d7">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d4742888-6744-4e89-8053-0f5d5e957123">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a05cb526-7b60-4c03-8942-2f3bf63c69fb">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b2afcdbe-5dda-4bb5-ba9f-09a5ad033171">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ca29a42-0290-4783-a5d5-ac57b2aaac1b">Pregnancy Status</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a744c37-d362-4e2e-91ac-d56cd7be7571">(0010,21C0)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7bf2b2d4-801b-41ac-a6d3-75f8a5bca358">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6a02858e-3c0d-42f4-ae53-1bf359988ac8">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ce0c55ee-b50a-426f-ad43-35d38fd6667b">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_67e2fbf9-b57b-417b-924f-85c445aab087">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_508cbf4c-2a26-439a-99dc-68b330d7ae73">Pre-Medication</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_46117ade-36bd-42ef-933b-0def34a482e8">(0040,0012)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ee8b235c-882a-4bed-bb99-41df002d7807">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4c3e2fd4-cfce-4217-a3e8-c71798146e86">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c86abe28-11da-42d3-a877-8df41005e550">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ee476b5d-bd4a-48ef-ad47-a9a577cf5a89">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82d2a310-9893-455b-ac70-2c5303b0d24b">Prescription Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5ee1345c-4cf9-4645-9a93-63a791070b6b">(300A,000E)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c817b523-a4ea-49b0-93f3-e845606b099f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2655435e-3f0c-4ba8-a8e0-8a9e2e80acfe">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7c40f605-4192-4174-9557-0c9353992e8c">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e15b1de0-72c9-4ca1-94ce-1f5b60470c9b">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8fe3c712-18af-4c1e-8802-4a6ddb1b8918">Prescription Notes</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_08e8415b-10e2-4393-a995-563f2724caf4">(3010,007B)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1f8c7054-cbc5-41a2-96f8-b7417f8e9a00">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a0885684-9634-40ab-81ee-14b748aba9f0">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3df299b5-b85f-4d9e-951f-fac5b2c02c49">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c8429ebc-d980-4963-a6ce-0ca65f909145">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e234c49-ca3e-4e86-8f8d-0f5bce98acfd">Prescription Notes Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7535359-bed1-4264-a437-b808990e4332">(3010,0081)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_065d83aa-725c-44fa-8748-593f12346619">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a375e619-ff0f-400b-91e3-240f9c3bb2f0">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_daf3bff1-99cf-4566-8460-c9771f36bcca">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9673212c-6549-41cb-be39-75b3fb62d9cb">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8ae8511-f74c-41b3-9404-05b5b9c4faa0">Presentation Creation Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9abf7720-b579-416d-b755-d46345eb3e7e">(0070,0082)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_03c18c20-a122-4121-b704-097a0cffbac3">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_26f1df38-2b1c-4e8e-8fd5-444fc637a910">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7f10f0c5-f46d-4eb7-99bd-f08514a8226c">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d756acf1-4d38-4c15-b59a-f4dc3095a7bf">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_55de0e14-6743-4a20-9b6a-56da086183e8">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_083ed923-af60-4674-97cb-d506b4eb4269">Presentation Creation Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_802ad274-5857-4971-ae96-c46c7c8635ed">(0070,0083)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7a0c6df2-d4e2-4f11-a457-3ded146ebbe7">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dcfe7c4b-79f1-4191-8e61-87fde0ca7f9e">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_26b8151f-cab0-4c83-a3e0-19be78be0446">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e21fd0bc-621b-404c-bc9c-5c11f1b2197c">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e9a4a4c9-e2ec-46e0-92c0-71f99b2485b8">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f15e6b2-bc70-4626-80bf-f258dd153f12">Presentation Display Collection UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5dd55c75-ff1c-418a-9320-ff60cf7c138c">(0070,1101)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_16b37613-bef9-4df0-8e31-f4ba3fd13b2a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_40d4fb18-7858-489e-8d72-1fa21d3fd0a0">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e19c24d8-378f-4f7f-8596-bb41b4b38f36">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_392df5f8-eee5-4e79-9cd7-841c87489bdf">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a0c166a-fa03-4b8f-b14f-30a1f848cd16">Presentation Sequence Collection UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f0c8200c-1e97-4bfe-a48c-abc755f264cb">(0070,1102)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf9de110-1918-4a9d-9ea2-8f32c090c5aa">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ce694f53-94ee-48cf-8004-2f7d25d480ca">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9cbe03b8-d948-45bd-86d1-dce7d7b057a0">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_04b8a673-6bf0-4b7e-b2b8-94e2645a8028">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a987e5c0-7a9b-40b5-8868-97f869621523">Primary Diagnosis Code Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a9ec2f0b-1818-4e35-be10-d5c6a298269f">(0008,1302)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_318dd6d8-db60-4d58-8b43-06ed04d1a08a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eca37599-cc85-4fb9-ac33-29de7f834b95">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fc2bdf4f-4c17-45f5-82bb-d2820af53e45">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f19bc3e5-acdf-498d-bbf7-327df24b9240">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11489e20-9e79-48ae-a8e9-c9ae73c52cf1">Principal Diagnosis Code Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_77d897db-bbd6-4d0a-b403-e9f6bdf82b00">(0008,1301)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ad585742-cd75-45c7-bbf8-f1915059cd0c">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f1135800-2003-47ab-b584-2680bd1c6144">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a26cd9f-9cf1-41d1-bf50-b147abe3d66f">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7796cbc8-2f9f-4b3b-bbaf-5c48707d0719">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_126b4ba9-bd65-499b-b538-300f9f55d101">Prior Treatment Dose Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3d5954b1-bdb1-44c7-9576-c570659e1582">(3010,0061)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fe5a2ae7-9789-4208-9e9a-62fbd650ec10">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_91ee2626-6e4e-4473-9623-dff172172fd7">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf9867a5-32ab-491d-a7b5-d4e5debdc4cc">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9c818926-111e-4d77-af84-d722a7cd2a71">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ccda522-eea9-47bd-b29e-819f3525f2e3">
                                    <emphasis role="italic">Private Attributes</emphasis>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58525ed3-4f63-424e-8706-8d8e99338c3a">
                                    <emphasis role="italic">(gggg,eeee) where gggg is odd</emphasis>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_41be1a9e-d072-4876-8535-cebb1ddbe1b8">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_543fdc18-3f1f-46a0-8345-07730fed8d59">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c3ecd9b5-3d22-4a21-acfc-3b2f4ac2c900">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b646f3fa-bcaa-448f-918d-c1bce3ea01ab">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a49c4b70-3c4c-43d7-b392-d0f916bdae66">Procedure Step Cancellation DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_02cbdaf0-8c9d-4f63-a59a-219e67acae88">(0040,4052)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9009dd74-1bf9-47fe-a670-600a39f066af">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_00e13d3a-78e7-47c3-a2b1-4d5a3464e172">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_095dbc04-7bd5-4421-a100-43954ea9fb33">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aec22495-bdb4-42d6-a7b2-ade9d0d79d77">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_92010c16-618a-4d09-955b-3640c9d0b964">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35965642-250b-4e73-b2e4-875861941fc2">Product Expiration DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_af506c3a-8571-41c1-9598-a52a55ad5e42">(0044,000B)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_22fa022d-9d32-4ee1-a63e-e3362d632d25">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f9a0512-f45a-4103-9c03-b5ef61bad3f2">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_106f4866-69ee-4ca7-929f-97753375c2a4">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_81a5c8d7-c312-4aa0-b812-32f540d3269d">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_af619211-f960-4a0a-831a-9514668d9010">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c535dc9b-753b-4e7a-b7b3-d7ea6727ceb0">Pronoun Code Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_90994640-223b-4e49-b562-e80f0eba975a">(0010,0015)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cbe73554-2543-4ed8-b516-69164e563e67">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a740c6b8-839c-4233-a958-703c58ae57e3">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5d2a22b9-ff1b-490c-80e1-5641b4d5c3b5">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37f32d01-d149-42fc-8854-ce587ddb2455">Pronoun Comment</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3176ab6d-efe8-4fb9-9999-da6ac062ea10">(0010,0016)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c2e5a731-3739-43a4-bf5b-67f5574d4e66">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_39b505ca-8c49-458a-b342-b9962c3cf6de">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aa67563c-73d5-49b3-b8c2-2fd0d0470c54">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f176e13-a65f-4d13-97e8-75049055d384">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c91590a9-7c32-4360-9dcb-b81884d45cd1">Protocol Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3a4caf37-9300-4496-993e-33d2bfc80edd">(0018,1030)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7d27dd88-b06f-473a-9c4c-287fad525a8d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aa62258e-d7d9-477b-aaac-acc5e8b7019b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b21f30fe-f42d-438c-82e2-83cffb3b98e8">X/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d0b84176-6fe4-455f-9f1e-cccb67514e5e">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97cd4cfd-854e-4f97-9e6e-78c060ff98d2">Pyramid Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dc9bc2ae-b742-445c-b344-e14af75feee8">(0008,1088)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_30e0a014-f757-4a08-84c5-7ff9253b378c">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85701a37-000d-4836-b0ee-a2dde21bf025">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_538ee977-060b-461b-9334-4212d03c11dc">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_afa90cd1-fdb8-40a5-98bf-7978e3b911e7">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2922ed7b-00f4-414a-aec0-f694392785f4">Pyramid Label</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_48ad0de7-cb5f-4ee0-aec6-da3570987923">(0020,0027)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_574e750b-b25c-484a-a15f-1d8eb67f00e3">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_49330c89-8263-4e9f-9c2a-2b049d19dbff">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_16ed38a1-4fca-46a8-8a2a-fc461b13aff2">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c8b36911-323f-4e4f-b4cc-9706a8276fcb">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f13c79f5-42c7-4dcf-8c9d-a1d1c810f2d0">Pyramid UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5244e752-40aa-4632-9f47-d6f669f41028">(0008,0019)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b28f38e8-bd14-40d6-a00b-098e7a898ff8">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3b781941-0e59-474c-9421-7cb4e8697831">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a38d30d0-05c0-4521-a53f-1b6ee4bf6e36">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_92ce3531-321a-4015-8fcd-0e24a48ce05c">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b34b3ff6-f23b-4cf8-a48a-fde6d17d43ae">Radiation Dose Identification Label</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5d906d53-5006-40e6-8026-4b537de5c6b2">(300A,0619)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2afe924a-ebc4-4971-96b6-7fa7ba0e6e86">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_19937f1e-5364-46d0-aec5-5ddf9711971e">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_998e78da-bd7e-4ad1-a2b7-1a5a3aa076c8">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b684b44c-5a38-4919-912a-009b62506c15">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3213dc15-c2bf-4537-bdc5-9bda1627de74">Radiation Dose In-Vivo Measurement Label</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a5ab5795-ccb7-4722-9e45-b03001b35579">(300A,0623)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b93153d-5991-46ba-b21b-ddee50a7a78a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9762d1c1-998e-4dbf-90c9-d941508c066f">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6979fd35-005c-48c2-a550-fc7c1a5e8933">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_419ad016-61f6-4765-abfc-3e935d05a15b">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67704500-a23b-4b6d-a11c-94a567be4c24">Radiation Generation Mode Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_815bc3af-40a8-4678-afb9-f5bfd1f00280">(300A,067D)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f46bfb0b-a739-4afc-bab4-3c009c4dab49">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ecf0a923-79d9-4936-9148-617eb0b7149a">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_83ef2161-8fa8-44e0-bd75-86714b83d5c6">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_beb80061-0cd7-4b7c-b786-1e703818d556">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_11536566-ba8b-46fa-bc95-2a2237c03962">Radiation Generation Mode Label</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3d6d8261-a327-4de0-b7d2-06f59670a9fd">(300A,067C)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7f28bb2f-4a11-44d0-a13a-9b63af112afe">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7b65c4b6-8432-4295-baa3-6ad84868b756">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ef74ccae-7486-46b7-adb8-518d2302f274">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bd2fa43a-2bff-431d-a83b-258e58dfa61a">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48d451db-7135-47fe-a318-854aae1989eb">Radiopharmaceutical Start DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_132872a4-a212-4156-b1eb-c541eb43fa3e">(0018,1078)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_baeb8078-d791-4305-a345-e667c0e5f4e2">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_231e7ac1-4a96-4fc0-b014-842579228c5b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_481fb694-f082-4690-8b3d-ec4213b62038">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_322afcb1-f15d-41a8-88df-fdb4355baf16">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_27bb9cbf-102f-42a1-9627-5c937100cfdf">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38d49c65-6c35-4eec-a0c4-4bc948a7442f">Radiopharmaceutical Start Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4893f62a-5b66-4fbf-8d6e-e3ed9f62e090">(0018,1072)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4fdf5524-565f-412b-a1bb-6d55e092f557">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6eca0020-d18b-4535-980d-15b8dd1118f8">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_61d91e10-e974-40c8-b7db-63f5be41810f">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_231cccea-b551-4f82-8c0b-c7e25e86d507">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cc859fd7-4f82-463f-a96f-f1269ea9b128">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3bc485a7-fdc3-4d21-8d6a-4c7bcc5e9f3b">Radiopharmaceutical Stop DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1d4e597c-1315-437b-8302-2fef77af36f3">(0018,1079)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d05577c3-5434-412b-910c-6e583d1d530d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ce4d7f81-9edb-435d-8a14-c6b873b977a8">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4ba00df1-e666-4ab8-a67f-bbcd2b954a81">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b20b611e-6969-4968-bc31-2f44d32233c5">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_66c1c0b3-daa4-4049-80cc-5c0ca24115ab">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5155dd1a-2460-4546-9023-67e9381b6c5e">Radiopharmaceutical Stop Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9090ba46-1401-4346-9807-6a77e879da1a">(0018,1073)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_31611acd-008e-4eda-a492-495a74469fec">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4b661c3d-67cd-482b-8b1a-e52f78f350fb">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_34f464d6-0614-4bff-a3ec-ce046518a15a">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9ad3d85d-c417-4bcc-91ea-af55edda627c">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_675e68d0-9e6c-40af-9bcc-1ba0618b1d17">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3d5c806-6e03-4b87-aceb-ecc8309a1449">Reason for Omission Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_79baa415-fd30-4ade-934e-0a9ad5bf5dfe">(300C,0113)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_748784f4-d0dc-4351-a340-867fa6ab3f3b">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_46a400fd-a281-4c9f-8169-bef060ccfa7e">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c287c7d4-8d1d-4ae2-a465-005f7b984e5c">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1587f5a6-04dc-4308-a45c-5aff31b4fac9">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c53a407e-a3f8-4c1b-94b7-e45474bb636a">Reason for Requested Procedure Code Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_00f8bee8-6068-4e6b-afd8-405adbc6ec8d">(0040,100A)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ffd8f2ef-7459-4681-ae58-fc0a5e485050">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3fc5034d-e0e9-4456-83e2-cb2992cbd5fb">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d1e54742-cbb4-458f-b38a-2d19c51e854a">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_67ec652a-1f65-4ac1-96f8-59b36b3d94dc">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_933708bc-e9bd-450d-8b2f-744f427d2fce">Reason for Study</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2598fa85-62e8-45aa-a979-1f939580c510">(0032,1030)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b796fc7c-3a39-4188-8a21-096df6515a84">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_466e5560-924c-4365-97c2-f22b791fffb9">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b749f252-83c2-42b6-94f1-364da46e45c5">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_19e06bf1-7dfe-4158-9b90-1d8b5f891063">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_370f3155-0ced-4393-95fe-a8b25d0cebf0">Reason for Superseding</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0790dd9f-e0ff-4710-af1b-0ece8a1d4266">(3010,005C)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_08bd5db4-a2f3-4d34-b58d-6ddd38baf5f4">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a415050d-58e5-4b49-9c9b-e3cc23fd4198">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9465158e-f6c5-4b7f-aa4d-1cb923c7b7c0">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1109cdb0-ecde-4131-8b5b-22aa6575d23a">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e59b05b-81be-40dc-9422-defb7d19a473">Reason for the Attribute Modification</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f9f1ac13-8fb1-4af6-8d0f-881e2245e6da">(0400,0565)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1161c9f2-536c-4ae2-83e2-439d2503ecc8">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8d135ace-00a8-4d93-98ae-9f7943becd5e">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f0cf200d-d679-4401-b632-b5256272cb52">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c2abf263-e10d-435f-9c2b-990a35b2b8c4">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e54ef81e-e6f2-46b6-a1b7-142bca3782af">Reason for the Imaging Service Request</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc370d5d-efe5-4229-909c-2d042b212006">(0040,2001)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7f92c613-8139-4291-88eb-75e0e27c11ff">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5a6f9f25-4559-4123-b0f4-51fed99a4289">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_26b4a5e8-de13-44a2-9617-ba28607b8653">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3d47e595-2cd1-46d2-a855-43ccf76b9b31">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2721db9-8f0f-4012-b371-a7ab07da65fa">Reason for the Requested Procedure</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_654f6557-a1bd-4038-bbe3-4f0ff6102980">(0040,1002)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c208217-9859-4488-bebf-1a5e64a1f74d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c33caedc-77c1-44df-aa49-a57aff43281d">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_47e75bda-abc7-4221-8a71-e38eec9e9a7d">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_decbff19-74bb-4fc9-b90f-5964c6e879a4">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b08901b8-e374-4dda-9bc1-3e3773d77ea4">Reason for Visit</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f243db69-aab6-41ae-bf53-3c23e796e9f7">(0032,1066)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_967a7d2f-0fa2-4112-91b3-49d360170732">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_602f928c-00cc-46ad-9565-31783ea82dba">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_81cb5e35-83da-496b-9c3d-3114a05ce290">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9496b251-34ad-461c-a150-86f690cb00ac">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cfb200ef-016e-4e18-957d-884baf8bb1c4">Reason for Visit Code Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_95d97680-912d-46e3-9481-939656815ff3">(0032,1067)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6b6321b9-3f20-431a-bd95-477c482b5dac">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c264d2ae-78a2-4d77-83d7-5571e37b1772">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_850efefa-8d3f-4356-acce-1b7b8a980308">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_57e93aa9-87f8-43ae-ab85-63b187bba23e">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb09efd0-3405-46ca-a984-56cc338173ff">Receiving AE</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c3ce0cc5-f334-4350-8308-c1365a4db4ff">(0074,1234)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d2a39752-4185-4197-944f-b7d74ef42ade">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_52bd8d95-9fac-44e0-afb7-9e9c25c5dafa">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8407a877-0eef-4b21-90f1-eceb3be819c6">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8de2ab24-61d2-4d19-8ced-38c4b46c43d0">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da1d1b65-8d40-4cae-8008-4a1daa40fc5a">Recorded RT Control Point DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_42d1bb94-1f2c-44cf-8884-634a309b8b8f">(300A,073A)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f285e93b-01de-424e-a064-93b80f5f99a7">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ab1ad1af-7b42-484b-ab75-6b62237bf2d5">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_449dc0ca-ba0a-42f5-b6a7-4e55ccb41b4b">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e780b055-2441-4a60-b019-1caefcced338">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_12464f5c-c57c-4bd4-af01-04b985f7b6c3">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_12916206-7b6a-407b-b7ac-3400149180b2">Referenced Conceptual Volume UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0edff033-b8b5-4355-a180-471f598d89ee">(3010,000B)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2d9b0d0e-54a3-492d-98fc-8fbcf5ad41e0">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_597cabf6-d20c-4c8a-a536-cac415249c1d">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_092eaef4-ee14-4f32-a542-0cbb78437233">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b70bc0e1-ff5f-4abf-b3e6-3d3f8f287c86">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_12934a44-462a-46c9-bda1-5e45818656ef">Referenced DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d59d806e-89d0-4954-886d-d2abca75c891">(0040,A13A)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3a91aadd-9f8c-4bfc-9402-c8d4e4980522">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e19bc678-661e-49ed-9d56-a6ac9223b946">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2ca03c68-41cf-402f-ab56-b934423d6194">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_09e73da8-0d8b-4730-9360-8cff04377819">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2be9e74a-b259-483d-bef2-f20ef963978e">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_56139c88-359a-43a4-8bab-ebf1333ad807">Referenced Digital Signature Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ee65eab2-dc1c-4a10-a448-1c81dab161a9">(0400,0402)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_607bab44-eb96-42dd-8639-f59f53703eab">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_db70a413-d588-417d-ad96-087ee60209e2">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0ee8c04e-2163-4c4b-ae1b-8e93beae62b3">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e52f1dae-9940-4ff8-a031-94662e5eac84">Referenced Dose Reference UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7b053f5e-936f-4e79-989b-ded76ca369ba">(300A,0083)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_23e7489e-bab5-4487-a025-c2547c4910cf">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dacd7126-c765-402e-b934-e78173e1da7c">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_264c64e7-78cd-4432-a020-d8d0477a3913">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_97fc848c-16b2-41b9-bfae-83a95c57ebe8">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42185c84-fc28-4eaf-bc0a-803ed7b5beee">Referenced Dosimetric Objective UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6dc67120-5ef6-401b-8bf2-0f3ec2a8139b">(3010,006F)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_19a02500-7843-4800-8d2a-b7984c846cf8">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_67b79aa7-c936-4409-b6ab-1710f2908e81">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_95368b3b-dd8b-4800-bdcc-b4d3254d14bc">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d26aa2ed-dd5d-4ccc-b5e6-eab1a19efb8c">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3b6962c9-4e59-4fe0-a242-7850b662d0a8">Referenced Fiducials UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_044b7af9-6c39-4922-8458-261d5ac16f54">(3010,0031)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1031cced-2183-473f-8b99-c8bd0c66ff21">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_411f85b2-4ded-4f89-a8a3-c20af7d7c6cd">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8e5ee3b8-5246-4712-9474-e285ed4f3f64">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_16e0fe58-67ff-4f22-8575-31765e015621">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81aff4c7-2833-4e6e-9acc-619829599c32">Referenced Frame of Reference UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_455710de-1363-4121-ba64-bc1d8e3936a5">(3006,0024)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f4503085-a94e-45f5-8c94-285e72316b25">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_055f45e7-4e95-4902-8e91-ebec76058c82">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_67526388-443d-4831-b6b1-8b1449e92124">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c2357d0a-9bbc-496c-a0a5-5950efcc6181">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e0756168-09f9-4a75-96db-f1c422ece271">Referenced General Purpose Scheduled Procedure Step Transaction UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_32400a90-3d9d-4cfb-b421-75012eac46ba">(0040,4023)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a77c0c54-2298-4cef-8f3c-d0f865dc190a">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6629cbc3-9eab-4762-9abb-616980a33545">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c8613d8-4169-46c2-ad33-da5571898ab4">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_929c4835-9a25-44ad-ab13-7b6b295598cf">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5d3b27f-018b-4b33-9188-8b34d1f06d8d">Referenced Image Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d20c00a8-60e8-43e8-ad4d-6aeb90490612">(0008,1140)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_913b3893-3171-4c72-bf6b-af95624f2a06">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5cca367e-109d-47c5-89a5-7263d35f676d">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b7d7629f-7ca6-494e-bf45-e1818d60ce0b">X/Z/U*</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dc0d2b61-2c0a-4113-82da-360f8c46f1d2">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca391448-f829-45fe-b660-4724543fd2f6">Referenced Observation UID (Trial)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8d48928a-210c-45be-b168-3cbaa3d6d267">(0040,A172)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c8971a39-6e61-4d83-a7d5-aff829a07565">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8ef4ee10-0f20-45ef-8fcc-42af6d43761f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f2ad1f28-f244-42fc-acd8-647493211955">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ceac4bd9-cbc9-4b7f-a6a3-007de9a2b3b8">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_13a86d31-d48a-4983-acc0-44e9cc5604dd">Referenced Patient Alias Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8a267ef5-878b-4080-940e-188b4cfc8cf2">(0038,0004)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_26d0b4be-9dae-4b57-ab18-8e524dde7dc1">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a2a7654d-e5a3-4465-9dd8-6ec862d73ca3">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e2454175-2059-4087-b33a-cfe145ebfe37">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04d7a283-23bc-48e5-9edb-bbf576c11748">Referenced Patient Photo Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_af1622e5-5c49-4f31-90e4-5a5a0f31911b">(0010,1100)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c9df51b1-b4e7-43b1-b03e-880ebae4168f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c5325eae-785a-4a41-991f-68f1b263b63b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b44e702f-6ccf-4566-a176-de115d84b1d1">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e71eba3a-54d6-41f7-aabf-61c7b93c257d">Referenced Patient Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_78122c59-81ba-451e-981b-d62a1f07ec51">(0008,1120)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9b780e97-79fa-40b7-8c03-0d452f31ab66">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d41fb15e-1e27-403e-853b-426a5995312d">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bf07f76f-4483-4190-bba6-b3d9b5f1697b">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_972acd6e-268e-4ad6-b292-e475acebc0eb">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2972fff-a238-4c6d-9a40-88e46fbc89b2">Referenced Performed Procedure Step Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6395337c-11a4-4ef3-a536-7347cea570d4">(0008,1111)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7246faba-91de-481c-aed2-76f71b9fe4b0">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3d269291-b753-4d8f-a88f-17586d014842">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ff7fed32-ce42-41bf-a279-84e1335402c9">X/Z/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_78880bb4-3fd6-4638-a774-eaaf50b558c7">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b3d5825-d32b-457e-b3a4-c98ffbc6eb0a">Referenced SOP Instance MAC Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_db41f7a7-f6fe-4f28-8149-3b5e7a658bf1">(0400,0403)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8eb552fb-dbfa-42ea-a3ae-e91014798ec3">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a60637a-503b-4f56-88c0-2077a0b25331">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_68c0089e-0c7a-4605-9e89-0d42f620d83d">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3dd70be-29b5-4e4d-8810-eaeafe6ee09f">Referenced SOP Instance UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5c34e2ba-894a-4321-86bd-7e0cc220fc23">(0008,1155)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7084351-ce2e-4a29-9e78-009e66a5265a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_240fa0fa-c44c-4408-9417-116adfa0339e">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_22f28f56-0dc1-4381-8359-a607bb617c4c">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b93bc283-bb98-4f88-a42f-36a7137b0a6e">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8951e3b7-3b21-47c2-888e-52e8de1dcb08">Referenced SOP Instance UID in File</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a4564c75-c1d9-4fcd-a543-06339686b179">(0004,1511)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2f149b20-6d48-4b7b-9552-57bee456d19d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0422187c-c5f5-4f46-9cad-468d3fcd13c0">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0f3a0a0b-b631-4379-8a1a-fd392067e1f4">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d0f36e97-89d6-43aa-bfce-4201530270c8">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_794f6bbe-5838-410a-bdb5-7201728f3304">Referenced Study Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_49ae1b71-e4ec-43ad-b40d-d8f81939de37">(0008,1110)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4b476f53-b2a3-4b52-af83-6635c27b44d9">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3dad4c64-5f25-4002-a74c-2c2a6493ce61">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b709f9f0-bf7b-46d1-b62f-7c67055c5d7b">X/Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4185c9af-7e65-4510-821e-b98fecaf1141">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a0ce657-a8a8-498b-9d2b-7fe4c827b5c1">Referenced Treatment Position Group UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_473c82f8-8614-4b3b-8a18-f4cc9adb2074">(300A,0785)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f18cf5f4-2667-4cf3-87f1-1479719a4138">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c26ae91e-ceeb-4e3a-9adb-6dea833741c5">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_de67f002-a37f-468b-a973-e680655ec9ab">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cb676272-d3ad-482c-9f41-49ee9fc5b2bb">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4a5b826-6610-4eec-8e28-d4f9a03328c9">Referring Physician's Address</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_55df3247-8c79-4998-a7c5-4e8c85c10de1">(0008,0092)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_543c0353-7b14-4cee-9f18-0e3e4e704b7b">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2f58a474-690e-4bd4-8164-1f7136b4818e">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f8eb7c34-b7fb-4b74-9b43-35a62b0945f9">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81bb6d2e-fe8a-4c36-8f0e-da4fb862d574">Referring Physician's Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d8ca0de5-8bc3-41e9-aefc-a8a81a0d8a03">(0008,0090)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a183e32c-bbe6-48d8-8f74-6ee16f70111d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a2440fb0-0b51-48b2-bb2f-85a10b1aea8f">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_822814f2-523b-4a28-90b5-cf210eb4c22c">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7df976fb-68d3-432e-8634-4375f37d6228">Referring Physician's Telephone Numbers</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_38a6f97d-6039-4ed4-9015-11afe3c3259a">(0008,0094)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8e03b9f8-444f-4f70-aa24-3d390d5e3d98">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bcb2538f-0ca6-4050-bf30-3dc82813e8a2">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc195a47-8863-4bf5-95cc-8cfeeab46dbd">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e2e999dd-6599-4a3e-ac3d-53b3e377d5cf">Referring Physician Identification Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_375ee96c-c1ea-47f7-bf1e-66515d988bbb">(0008,0096)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1cecb94c-a19e-4a51-a3f4-2cb4c0b2ecae">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e60a55a1-e67e-42fd-966c-cf3bf34a3f0b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1c1d9980-3b49-4fa6-a515-f79fffb351ce">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c24571ee-98c4-463b-8f68-288a11dee78f">Region of Residence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0c08b62f-81da-4454-a9aa-0568dd3a17e1">(0010,2152)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_192b64fd-038a-4bc6-bca0-8dcb96ad5937">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fa71c132-ca6c-49ca-bafe-7536d13e6521">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d519db1c-122f-4deb-afa4-4e5e9f68854f">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5de5ff3a-1439-46d4-917e-fef54a74063f">Related Frame of Reference UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_33b2c33c-5006-43a7-a9dc-dfa5d21b3ee4">(3006,00C2)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ca8b78a0-856f-454a-a5e8-947f5abd6337">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_09c409fd-75d8-44dd-aa15-c84bdd4f09c8">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3c41fb65-5793-4617-b71e-2f8a8a396ed8">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e2f89546-8f5b-48fa-a3e8-bf817dc97bcd">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_615d917f-f7d7-4eff-9d45-7cef74a9c4f0">Request Attributes Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0086eb24-2dbd-4a7a-8183-82b2324af681">(0040,0275)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0a0a0570-e359-440c-a749-880b61f9b874">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8260db7c-7260-45aa-a784-9281120094d0">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a72d6ef5-730b-40ce-8ff1-80c215f0952b">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_593ccd4b-a2d1-41bb-a7de-c95828ff9c2e">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_238c8f82-20f2-4e10-8fad-98e5a215fa01">Requested Contrast Agent</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_17c61517-cb9e-4dbd-ae51-93dd196e13d7">(0032,1070)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8e4815d0-a1e6-472c-8df8-a697c480aab7">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7ce484e2-5c59-49e6-b87f-a18998e9efc4">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_07e1575b-3f71-495c-a60d-1afe76769d54">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1451600c-88c6-4e16-bf01-4286b5bc9ab5">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62eed195-bf11-4582-bf68-b82dc4671a0f">Requested Procedure Comments</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_26a03fee-9a45-4e91-ad74-24e568373d52">(0040,1400)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_94dab378-6620-4338-b845-cd4671fbafa4">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_62d25cf5-8908-45e1-b552-d3c3c051d0cd">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_709b11b5-994e-4274-95f9-f1b53a67766d">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b0e91c4d-fba8-4e0b-ac28-2a4f0114e610">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a279036a-a992-4ed1-9df2-433858e459fa">Requested Procedure Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fc646851-20bf-46db-9c04-f70623aaf955">(0032,1060)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_20734e74-fab7-43cb-af1f-1d25dd691b02">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e283acd4-1a0e-4ff4-8137-2d5015e5ebe9">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_feb57f89-390d-4130-b5c8-a887c8866fe1">X/Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_df421da8-8ec7-4f2a-84ae-36dc3b6b94d3">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93fdac65-17bd-47dd-9dcf-6723269cd86e">Requested Procedure ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2fceb609-bf9f-4bbf-afb1-6895fefc8dd6">(0040,1001)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7acdcc30-2765-4c23-aabe-fba4bcbf3029">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_28309bc0-6888-4662-b503-bd3c40acc6b0">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0152ddea-6ce8-4fee-8a13-45ecec642aca">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_366dae31-c375-47f3-be2a-e729ab687de9">Requested Procedure Location</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_710a129b-b24c-4770-9f97-8532d3fe9129">(0040,1005)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_50120816-c44d-4857-97d0-4ccfa0e915d9">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_da83d155-6355-48dd-86ab-dbfb33ae759e">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_57af229b-a94a-41ad-b96c-d0517279728b">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f4102ba-a010-461a-9a27-e0ae121fb632">Requested Series Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_59d131c5-e246-4de4-bfaf-d1d2fb2184d4">(0018,9937)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b4888ad9-d7a2-4b1e-b36a-4d7b9cf4937c">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f7e4fcc8-1302-4c4e-baf1-f819cd32e579">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b6c6d84d-21db-4654-a9e1-f42532297d82">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7477915-9b18-4183-8961-0ef74dbfe5b8">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_da42d69d-c01d-4567-a53a-31f858b5f55e">Requested SOP Instance UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_09bb6000-049d-4eab-92fa-881c77c03e2c">(0000,1001)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_38d6eeb6-6144-446e-b849-22c1054c6a7a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8286ec77-3560-4555-8702-f21eccc5561c">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c554e208-f640-49db-ab9d-ebe181935c18">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_71a3c761-233f-4fef-9bd5-87a0c47dcd9c">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_859e172e-82fe-4a91-8ada-b58166cd40bb">Requesting AE</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c68699ac-e06d-4a53-b98e-0aff1a4ba066">(0074,1236)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_96c6b421-97d9-47bd-aec7-8de876ef3263">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_461bc3f6-6f3e-4c31-bdbd-52afbb425355">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5ad6075e-6b79-4171-a463-60c78b45fe04">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d5434444-0b23-4b74-9b69-e05f58bcda5b">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c74c62ce-f3ee-4758-9e27-d3165743fb0d">Requesting Physician</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b03bf61b-ef3a-4483-9467-f0a592b6e9d0">(0032,1032)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ada01323-e8e3-44d0-8490-1c96af4925bd">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6307f3f7-dd81-497d-8e03-1564420af25b">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fecac81c-3c3f-4c6b-80a7-85b949d42ff7">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae8ef295-818d-478a-aae8-f88a3d26baeb">Requesting Service</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5a46a4bf-d2df-4c8b-80cf-855eac474348">(0032,1033)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_11f26bd6-9a3c-4b9b-a5d2-ccd5688f9bf0">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b489bd41-b7b9-4b72-8ec9-4e59f0a3fa5b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2f70f88d-cb51-448f-a114-154bc42f90c0">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_978fd605-94d5-4032-bc25-345b988e87c5">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e0032c32-bc69-4c37-960c-baec94777938">Respiratory Motion Compensation Technique Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_24c6a7a2-211b-49bd-a82e-6cd45447a1c0">(0018,9185)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_46f9566f-e725-4ab0-909e-6d59a3d878cc">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_32002391-8057-49c5-b0ab-4ba104a9c216">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d835e770-baf4-42ad-aa86-2c65de081f8e">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c91c8ce9-3d2f-421b-9c05-0e069fdef082">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b2aa958-ddca-4d64-a8fd-6d2d0d4133dd">Responsible Organization</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1672314c-e821-4baa-8b35-939d50c832bf">(0010,2299)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_87a37043-dacf-4c50-8135-ba9397229308">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_201b8d18-3753-450d-823a-2da794ba6e3f">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b946d25-3603-43d7-b517-a830957b5887">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4ed86f0-b9d9-4655-818d-166621ba56e9">Responsible Person</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_21ffd891-5bf2-46f4-9622-4182c0e810c6">(0010,2297)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_297cda4e-9b69-444b-9ab8-fc2517a7bb6c">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f3e4dbc2-435a-4444-9378-43cbdf1ec360">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_470c4b8b-029d-48e9-b486-189e0440653f">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cac17402-f304-4553-9895-2942c37b29c3">Results Comments</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f831df61-47f7-47bf-a892-a5d5e3e72416">(4008,4000)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6455bbbb-521f-4850-8ba6-61be487169b0">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ed426363-9aea-47d3-a784-b0750a5724f9">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d3951aeb-5013-4682-8912-e837228fdf9f">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_36612839-748b-4565-9be4-6c99a54b7cf4">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e596040c-8f29-4670-9168-42f8fbcaa7a0">Results Distribution List Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5bc064eb-7630-4267-a62f-bdc928c0b9ba">(4008,0118)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_208839bb-d1f7-4a1d-8bc6-b87f41e07424">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_757de3c3-4b2c-42ac-978d-b9eb267ed539">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_65ff19f0-3d62-4386-b31f-e6daba651b0a">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b219ecc-fb78-450e-97bf-7ce86aee2caa">Results ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5daaf804-2e05-42ac-910f-0e75382a42a7">(4008,0040)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7adfcad8-0664-4ecc-ab63-2faeb5206749">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_52a31d59-6405-4067-82d7-69f035a72958">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_df9f911c-6255-47d4-82e6-8e73e734a258">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_23e10d59-51d7-4dd6-b154-ab0ba78004a9">Results ID Issuer</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_708819c6-0fec-4fbe-abe3-d245a8832b12">(4008,0042)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_94d72517-40f2-4a50-88d2-8cc066b83914">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_da9590a5-5bfe-48c9-a866-6a3ee65aacbf">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc1b05d8-b2bd-4c7c-93ec-5d6d3546eb25">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1669a8c7-3e4a-41bf-9b7a-3cdcc65a9c4f">Retrieve AE Title</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73de387b-a841-4a4f-b722-408db6571410">(0008,0054)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_255d36e2-d537-486e-8d5b-4b1bc6dc9b02">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9c2dbd19-ca6c-44b0-8e13-6a34c8704ced">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c7a1c9d7-09b1-4c14-94b0-f3a947ef2b65">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9e949312-50cd-43ba-8c18-4635cc929587">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ccbcdc7-f1f5-4e68-a0d3-601e8542b240">Review Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0bafbb31-288b-404a-9518-2cf4de887338">(300E,0004)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ade7f9ab-83be-4fb1-b1b7-4672fcbcefd6">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_57e8db73-5895-4b06-8a0b-582ca9c93d05">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_559b4f44-272c-4842-bca8-3a76b4204d1a">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_db04d560-e245-48dc-8fb3-746b0cb59e5b">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ac9c2d3c-1de5-4985-b303-a58bc9bb129b">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7f322a7-911e-4a69-a552-11d50888bfa1">Reviewer Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_986c1993-190a-4de4-bc83-7f45fb1cf57e">(300E,0008)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3be6628a-2343-4124-bcbd-611b62f71588">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_59d77d78-0003-466a-8e1f-92f66da744f5">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e656ec02-167c-46f1-bbe2-f0312df72809">X/Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7a0c8928-b9ad-438c-a144-4aad1ad1809a">Review Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c419efd8-335d-416d-aaac-fe8f9727039b">(300E,0005)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b3805707-82b3-4771-9015-62d912ad1715">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_84956477-22bd-40e3-ace1-d36f42af5866">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c1b271c8-dde4-4a70-966e-1716c6793b62">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0800a83f-3183-42aa-b742-c31e6b6722e7">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a386ca22-4c29-4fa6-8e3b-4c4d2e9201cf">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f3ab34a-1273-4504-9dcc-635599924d22">ROI Creator Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69be4e4e-096f-4057-897c-51fa22b4c74c">(3006,004D)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5b3fd879-affa-4b55-8453-462fc7e29f39">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7c0be2d-8c47-4ff8-b3fa-7ad2f7f231d5">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cfbe9cb3-d0bc-48bd-baef-9a1df0376236">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f22467c-6e00-43fd-8f0e-973cc19dc265">ROI DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2107427a-bb65-4a3f-b9b5-7d308e993c06">(3006,002D)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e319060e-2f41-4915-8cdf-6a404f9440ac">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb814c52-64d8-4a37-b7aa-5f19902903d3">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d1bc9f00-369d-40cd-b9bf-249cea4b9af3">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f92f94ef-57e4-4650-bc59-f5ff1dae8e97">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ee869795-fe5f-49b1-b5d6-01f664564ad1">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dcdf6004-b18d-4af0-b9f3-890bbcd89784">ROI Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bfd73a82-40f8-47f3-b6ca-1fb299f4ef74">(3006,0028)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_146cba30-4f20-4529-8b4b-b38e1896a8cb">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_98074222-3fb9-4e41-b4a9-bcf1f89a7298">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_53b7eb9e-bd46-413a-b0f0-e64b16ca6744">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_284275fc-a911-4cae-a646-bd7b3c4f9624">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d71ed27d-793e-4177-84c8-2900c48c8b6f">ROI Generation Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ceb94b61-a93e-4a3b-99b2-eeea54c6636f">(3006,0038)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3f8eb4a7-0cf1-43b1-bee8-9f9223cf54fc">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dedade80-9bf6-4d37-8b97-c1005dfe787b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_42d842f6-0370-4814-bc31-94e6c3bde54b">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bf708725-26ba-49d8-8d90-e0515e2ebf98">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51d16e78-ab5e-4ba2-bba4-f289e188c0b6">ROI Interpreter</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6737c5d4-96e1-414a-994c-1ce1b2487efa">(3006,00A6)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf2be8f2-0830-4675-b177-e20360a89f98">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_178b6535-eb83-4a91-81d7-db5afb61ae21">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ee84c580-79cd-4fa4-a9d9-2ef20ba35a6b">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2169445-dc99-49ce-bac2-db364cebe107">ROI Interpreter Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_121f83d8-39a9-4621-9f21-3d11675a5ea9">(3006,004E)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dd1a3ff1-43fb-4318-95ba-355d2fb410c9">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c95cf5bf-9c22-4212-b0e9-65e574e5e945">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c8f85d9c-b107-4636-be69-53ac416ab862">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0d6f5b0-a351-4e09-bb00-622b0d3f1b06">ROI Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_84eebee3-4efe-462a-b429-659f7a783f6e">(3006,0026)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2d60e5c9-897f-40f4-ba3b-d97dd27ae105">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eaf487ca-2271-45ff-afb1-0d21a8d2297e">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_43a2099a-1fb8-4968-8bc5-1585ea3752bd">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1f2220dc-2558-4d8c-862d-04245f40492f">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d2cf348-81a4-467e-be53-3464562c8ef0">ROI Observation DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_91776058-7449-4c6b-9f92-feacbb2174be">(3006,002E)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2ffe0c6c-f8e2-4c01-ba2e-3661c7ace963">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ede7cabf-c1cc-4357-95b8-6a9225832cdc">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9ef3be4e-0704-4cd9-875f-006ded137f65">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3675f140-6543-47b7-ab45-6f57ee259300">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_097d58b7-781a-450f-b09f-420449dec7ea">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4cb35c83-11ae-42cc-a6bf-4a4546872f0b">ROI Observation Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c3fa3e81-3ae6-4583-8029-019555af31e4">(3006,0088)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f5926c4e-ba6a-419b-a90c-7a4e9642664e">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_82bfcaeb-9b38-4ae1-a600-be8de7e33427">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_68869fbe-2857-4627-b3d3-bcf034f24ce2">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9864e6a5-65c6-413f-9306-79aa429318b6">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_286838b0-fce9-4243-8baf-94b52af02e79">ROI Observation Label</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2b48f03f-b14a-40cc-ae1f-7edf011b3152">(3006,0085)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69173dcb-30f0-4e70-b4ae-4c89f6c1c8eb">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_454a04b1-5a76-4c0a-a163-8dab3eb501ff">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3e2057b7-b37d-4d38-ad73-f1b27a3a207b">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5251ae84-6c3b-400b-a433-56cd7519272e">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6b2fde84-8a06-476a-a169-84608643a43e">RT Accessory Device Slot ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dbb4b198-f3e7-4e96-bc16-f67c63c1e641">(300A,0615)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c881859a-71c1-424d-a0db-52118ce7ab35">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5c8e3114-0100-467b-8bad-811151b32579">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b97aa117-ce5f-47af-accf-b9c4d9d03123">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1deb763c-6e56-4b7c-8ef2-2b0e40c4d9e5">RT Accessory Holder Slot ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6fdc190f-bdea-4188-a77f-76a80d9c4fe1">(300A,0611)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e16aedf8-485b-4029-8a90-f43cc567db79">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a88382b3-909f-493c-920c-d1c3698e209d">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fe00090d-7f8d-4164-baa0-aa78f3d7f336">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1012ae54-a333-4428-9474-41d93c935a7e">RT Physician Intent Narrative</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_490450e4-a44d-430a-809a-36e5f04b7c2d">(3010,005A)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ce4074e7-ad7e-4d34-9638-9ddcbd8c3b0d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bdf623f8-a694-4713-9ba8-0e0cd678b42f">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e472418b-42ee-4831-a4e8-66ff0d61c05d">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_efe3100f-dcf4-49e0-9849-c551d833656b">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f65679f-149e-474f-854b-c0521f877287">RT Plan Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_49093978-8edb-432d-804d-f71c8031ff08">(300A,0006)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fcc49b51-a702-4b15-8de3-7b562eb6f3cf">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2a5a85ce-975c-4832-b12b-0ce564837568">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7c500758-1300-4d13-bbd4-b577df67e2c0">X/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73013def-b2dd-47ad-bf64-b1182bf9f059">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ae057433-02c5-40a1-a411-d75cc5ba3449">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f81fc0f-27c6-4b0a-abd7-c4599fe5b31c">RT Plan Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1bbee88f-8f4a-4c71-8bdc-d5f24eb4c555">(300A,0004)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d41fd83b-7fe8-460f-9262-9005fd6572ee">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb6e3c88-cf29-4513-bafe-053cbf61456b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ae1ee47-122a-4643-8038-f426aa057129">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7a8518cb-356f-44ff-be16-9b2cc80fe974">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b9253a3d-53d0-43da-8cc2-bbd2dc0b1b2a">RT Plan Label</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fceda224-00b2-4aed-979f-ca5b6de0830a">(300A,0002)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_76b7baff-b62c-4df9-8e08-70c42a35d22a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0cb5b0a6-bff6-41cc-9ebe-f70d4c021438">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2778eb6e-a2c6-4cb8-87c0-d36e7bbb870d">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0c1ba500-f1df-445b-9616-4f358101caa8">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec67349f-0294-4a38-8942-2c76a32b115b">RT Plan Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_713c5e8a-111d-4018-8b3d-da80b5fe0f9d">(300A,0003)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_67de8e4c-782d-4eb1-91fb-2491b5d50135">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f07b4312-1ad4-44aa-91a4-f02061d70d02">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c1fb6d85-3f29-4c73-b1c6-1f64ae89f969">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f483cfc5-ff8b-455d-ad6a-ee2e48390732">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a20de7e7-c9b0-4011-a275-c354e90c5e8d">RT Plan Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c23394e0-9bfc-49eb-851c-4480cbba4ec9">(300A,0007)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b2f75994-486f-4122-9f3b-da5e5fdc1040">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_387faaf2-3414-4ab6-a7f0-7bb687e5b067">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c751cf01-f74c-4f92-824b-b02c6f11b9be">X/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_354ec6d6-dd3b-45c0-a57c-e3dec2477bf8">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d5582dc3-4220-4c7e-8ef6-647425d722a9">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9845955-c24b-4972-9b1f-047d3a4b30b5">RT Prescription Label</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b9cf9d8-8938-46e4-8d50-abf4e194bd4e">(3010,0054)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f633d200-4300-4f44-940f-cfa55b58fe57">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0c13fd6f-3708-41f7-bb97-a2c94b3dd9ff">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e0df5277-79a7-430b-b721-8277a277e589">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b3ca9249-2db7-48fd-8dc1-b751e586a905">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa2a0043-4945-4495-bee9-723ed355a7ea">RT Tolerance Set Label</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d8fd84bb-62db-4604-ba50-073d56b14d56">(300A,062A)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f2e0c180-0772-4f88-b090-12bb36b58898">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e0de8400-955d-45d2-8f43-57e558daebc3">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_defd8356-1370-4a12-bb6f-a0226f857eee">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ac135460-f89c-4350-9c3b-32cd9ffd8711">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f778021f-408b-4285-b1c7-919e4bc3ab1d">RT Treatment Approach Label</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ffacb79e-07a1-4721-8470-7f2ea8377b4f">(3010,0056)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_79b1fa62-016a-4b5a-b6cf-92049043a238">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_48011b73-0882-4438-a286-858219f89a3a">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fe9755f8-0744-4aa4-80c3-bbcbace08025">X/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6d15af26-68af-4d39-9ee7-cd5f3057dacf">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc105c86-f54b-4559-8c28-a22bab8c39df">RT Treatment Phase UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_68676e2e-f42b-4232-b946-01d8058b92c3">(3010,003B)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e845f66d-0d29-4e85-b6db-4f5f01e6ea7d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3f32fa53-ea4b-48dd-bb48-88120aa8c885">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_797f695d-bc72-452a-a287-74e4b1b09e70">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e5487728-18a2-4af3-96c0-62efc2c060c8">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe3be9dc-f9fd-4690-86a1-0f4cc18efea9">Safe Position Exit Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_66a8a7a5-619d-42b0-8f42-0ffc56031100">(3008,0162)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0882a190-1483-45cb-95dc-4a4e310ac1a2">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73f105a1-3d61-4631-aa95-97a90bbb8a6e">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7fd3c589-8b9b-4893-b38c-863471d7e894">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f1bf69f4-6125-44cd-af4f-0aa3868fc286">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0b4127cc-9e15-4de7-ada0-1a62006b1965">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9e713ed-1bab-4c20-a469-9976eaa52ac6">Safe Position Exit Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4accda56-5367-4ac7-8a10-288449689453">(3008,0164)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dffc58c9-1ea9-4d45-84e2-6274cb0faba3">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_04009c0e-2345-48fd-89e9-c0f9e8b333a2">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5c4cec5d-e4cd-4a22-8e73-8ad5e4585629">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_17f3ba34-e645-4863-bc9c-856ab24cc6b0">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7d10b01c-803d-4692-a045-f458d409d944">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8559599-308b-4ce5-bc45-4baddf42f69b">Safe Position Return Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_134c245c-e328-483f-9fbd-d74e698b36b3">(3008,0166)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_34ffa7b2-ff38-4c67-9dec-29fa79638414">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_806af62a-50e3-4bec-9f8a-43ca14a05b16">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ceb4f2c2-1c8e-4615-b535-dd4ddb2123e9">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d0507752-6997-478c-87ad-711aac98ee9a">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1c10d4c9-9d92-47e4-bd90-3a0f08da21ad">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27c8d28f-a418-48a4-a207-e1425b57e295">Safe Position Return Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b6ca1878-85bb-4bd9-8449-ae23a244ade8">(3008,0168)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6e8c5e0b-f5ce-42b3-8003-025a542588da">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_44544ec2-a4a2-4daf-877e-8b7a96c1a5b1">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e2f6cfc8-9985-4f0a-a03b-4a9e2d5d45e2">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aa0a8de9-cce0-42b1-a313-feda08a6833f">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2d262339-1042-483e-bdbb-b22140aea84b">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2a35e3f-80ad-475a-be5a-8b2c4af51795">Scheduled Admission Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_df134285-848d-4074-9462-a9540ae0cea7">(0038,001A)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6bbab4c3-a5f2-49e1-943c-dd7f3305b795">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4552287c-98e4-4c26-ba11-46f66b65cfa9">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_591b64fe-bbc8-4143-a855-321099845c9e">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_999d670b-c839-4f5e-845b-1e9c1740d7fe">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5dbec48d-4116-4d6d-8f0f-868faf1d2be5">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ea369f5-65fc-4ff6-a287-15412c71f580">Scheduled Admission Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_30d712cc-7be5-44a5-b46f-8f44291c38e3">(0038,001B)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9354bd50-bd0c-445e-b217-c40a4e09c9fc">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8da32763-9138-4b1a-8de7-10f302999021">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e2b7a413-22b8-4ab8-a1b4-ff02a2896b59">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a657e74-a554-4595-b358-9260202b7c41">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e6dfb10d-77b9-4d17-94f9-b11c208f51f8">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b2263a6-f1dd-4445-8baf-2610d0967007">Scheduled Discharge Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_13c2ffbf-9564-4e7c-bc81-1d1d13403374">(0038,001C)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fcdb1d8c-fb30-44c8-b01d-0f4b358957ad">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_22f3ee6c-da48-4038-8a0d-8d70bc08ba16">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3e9b9ea0-c305-41ff-a370-db4431184068">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1ca04cc2-f315-4612-bd42-2b2b6af4cc64">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7801b4bb-1e8a-4ac1-9227-c7b9292a8443">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7530f26b-43ce-4a8c-811c-a8ddb385af19">Scheduled Discharge Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_96ffa79d-5b87-4f06-87a5-e13b3382bd59">(0038,001D)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_476997f7-d806-4a50-adb7-aecd7db8caed">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3b109cc2-15f0-466d-a6e2-5b5c787c289d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7c094577-57bd-49d0-9297-0527e5571aaf">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_61af1442-3c96-44bf-baf5-aaaa158e2b10">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_acfbee4b-a8be-4bde-9db0-20bbfc24c146">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_869083bf-08fa-4237-b770-8eef1ec8a883">Scheduled Human Performers Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_71ab699c-901e-42fe-819a-fabc5ae28825">(0040,4034)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a4c790db-c7fb-40b2-beab-07e642b17ee0">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e8cb2193-edab-4a3f-a9d4-2fa231f9299f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a86fb4b3-8474-49f3-aeef-9ca54bfece77">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c65c45c4-7974-4098-8c69-97404efc426f">Scheduled Patient Institution Residence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b9350826-4ecf-43b5-8952-3c03a45b943a">(0038,001E)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9b253867-6998-47d0-9544-21700156b0cc">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_83f2571e-0f51-4552-9a5b-6f568f7361c0">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6caa1be5-a9db-48c1-908b-07a31fd6aff7">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_723d7c50-bb32-4562-b7a0-cefd46632fdc">Scheduled Performing Physician's Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aff35c1a-887d-4c3f-ad5d-33e149c54b02">(0040,0006)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_59d870c7-d9a9-4e2c-b7d6-b24e7a5a791a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_df7e5190-e6a6-4221-ba24-b513fae8f39d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2553ed61-d70b-459a-a295-acc415891b9e">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4289424a-9231-4ed7-86a9-9114b9f871e8">Scheduled Performing Physician Identification Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb446b0f-6c75-451a-b346-336782ca9705">(0040,000B)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b4462865-edc4-4398-97b8-17f089ca7bbe">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_21a919dc-9cc3-4c6a-b89d-fbdab9707c5d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7155e715-2daa-4bb6-ac84-37d93b9f1bae">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3a8e384-dd95-4d8f-bfa1-35d653664e20">Scheduled Procedure Step Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1edd2cf7-c70e-4c0d-86bb-a4c9cf5ccff5">(0040,0007)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_63ba7745-af8a-4822-8124-1f0a8b39077a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9b7e65d4-0486-465a-8a3c-b4d1195fab32">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_77ae1255-172b-4f46-b630-b682fbc68dce">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf9a5b53-5414-413e-91b9-89961f186500">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f38c8605-c3c4-4fdf-8816-0edc6b3e5091">Scheduled Procedure Step End Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_defc52d8-f50d-491e-8fc6-a12b1059f8c4">(0040,0004)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3728a926-9788-4c5c-b056-31cfc7a8ad6d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4884db6e-eb60-40ce-8093-510d48d824eb">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_59c0893e-d864-414d-adb5-fedd33e2e7a0">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_46aab857-effd-4045-806d-ceb71fbddb98">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_46a1c927-dc85-4a94-bbb3-82c52d85fea7">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_621d9ef6-4dfd-4d51-a5f7-334d725f9be6">Scheduled Procedure Step End Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_810c085a-6cb1-451c-ba56-19e74ad43cbd">(0040,0005)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_018d9369-bb8e-4038-b9ed-067a6ada802d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d9a0b20b-e325-4728-993f-84a2ca0e17bb">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_54c03956-ebc9-47ee-905e-d162a21938a2">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7cf6694c-3fbf-4ee7-8141-9eadb67eea29">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6495d72d-e849-40b4-a4f8-be75e118c38a">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_977cb42e-a0d6-4647-b355-1102723ff596">Scheduled Procedure Step Expiration DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5a7bd997-842c-40f8-923f-db697ad76b67">(0040,4008)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bd48b9b6-4938-4623-bf6f-fe35a0ae3746">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_408c5416-0df0-492d-bc3f-eb7d888ae3f9">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_24922ce9-499b-40bd-bb22-7e91a2af15c9">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ddab7d29-bbb4-4445-8f5b-90910b594c81">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e41faa63-b25e-4605-aa15-d069b84924b2">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d04e656-50a1-464f-9cd3-316d677fce80">Scheduled Procedure Step ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_083556c8-b5c5-4d58-9c49-308460d2d316">(0040,0009)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_21ccf7bc-49fa-41f6-84fa-e131fcfc5b00">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_769da698-a574-4608-af48-c3515ea2efc6">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7820c17-881e-4866-ab9d-1f77ff151d8a">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86d57a37-81f5-470e-bc00-0bfe4b8dd068">Scheduled Procedure Step Location</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb39ae54-b05c-42bc-9fa1-fc57cee0a2b1">(0040,0011)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f2192ee8-fcdb-4fdf-8723-f49c0e5649a7">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3ba7b1be-edd7-4182-aee5-cb665d294be7">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fa311cca-5e29-4c35-be1d-2553d3260595">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2d1b320d-dace-4be8-8368-c1c4a0a41db9">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59e28d89-08d2-4453-8c80-eb5f600e487a">Scheduled Procedure Step Modification DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d440ae9b-24c6-4a81-a5e7-ed3af3e50b6a">(0040,4010)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d25125c3-ed91-4c94-b36b-569e1a73ce69">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2c68d786-d938-4c6d-a3c7-3c888f958967">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8001824a-3b29-45da-85b1-69d286ff8ddf">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_56a6d7c9-b044-4095-b5fe-c9d9d5e22ab9">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_05ef5caf-d0d7-445f-ab1e-e5a3458fd66b">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22453877-9706-4cea-a45d-24855d295ebe">Scheduled Procedure Step Start Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6d060032-8d37-4507-9508-bb1760933c58">(0040,0002)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6735e044-c0a4-4626-bce6-a74a6c5214c6">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_49a90fac-3dca-45a1-aad0-9ec5dd34500e">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_74662d34-e4a1-4891-a49c-4e1e68296e99">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a9af2905-7fec-4c55-a68c-86f25ab64ed7">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a00327a4-e547-40c3-91b6-fa673ede7feb">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51609877-72d3-4930-b08f-68345ef16630">Scheduled Procedure Step Start DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_046e3978-e868-4c26-9351-92b5ba8082e7">(0040,4005)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cfc01141-8a22-44a9-b6f3-0de6e0251281">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_31773cfe-d6ee-4d7f-8536-995f785f2f2b">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1bb562d3-9b3a-4ae3-ba16-d22b993d064b">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ac52abe9-1790-436a-b9b4-77477521bdf1">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_af13798e-0676-4675-a22e-c361974b82ac">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c0e5215-2559-4fcc-aae2-cc95d593210f">Scheduled Procedure Step Start Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8167971f-f1f6-4a34-91bc-2852c3d0c1f5">(0040,0003)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1513a891-c98f-4918-813b-816195c66145">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c6fb97a6-0491-4cd3-959c-f3969a239b13">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1efbf09a-e63f-440d-b47e-b995967416ce">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9b05a461-2075-482f-a6ed-9a51ed487f5c">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a6c23343-0f58-4fec-9590-0778211cbb9a">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f9ea7720-cc65-4c74-b767-19b6494e6a07">Scheduled Station AE Title</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1acccfb9-9e38-4181-8c1e-a66d6ef1d1da">(0040,0001)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f5c8ad1-71ab-4d45-b5a7-ab1641b536f0">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc758db0-a89d-46c0-a874-3992553c6118">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ff7ea987-08ca-43cd-b274-fc6a2c0d4e71">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0d90207f-f371-449a-b70f-7f0ab723f1cd">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1584b5c-35ad-49a4-859d-54abc1952c44">Scheduled Station Geographic Location Code Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d9df0e99-5485-4582-a1df-4bb8cc80f6c9">(0040,4027)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9c9a8347-7b37-4381-9711-612add79016c">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2077da54-85d5-47d5-abb6-ce9876789f04">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_41607b34-38f8-48cb-ad50-40ac09545a81">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c75414b7-9509-4278-bf4f-7fc2d7ac40dc">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9011d86-02de-4a46-9f1a-4e68b249cf8f">Scheduled Station Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_80242171-c8f8-4c0e-93ef-e07507c6772b">(0040,0010)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cc61ce5a-182c-4052-be98-fd1a208ba4ea">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_279419f7-cdd0-4bfe-b161-cf1adfcb1b68">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b81b9010-bff1-4884-b5e3-ccd8b042f604">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_46a853b9-fd5f-4072-b4c6-3cdb43e4766c">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_501fa5e1-fe07-4dcc-8081-4993e2325af9">Scheduled Station Name Code Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_37af3290-bfc5-415e-b522-4e7b9b1c60a4">(0040,4025)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7d2e391e-0e45-4dd8-a849-7349079dcd89">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8fd570c2-4271-4dd8-b5cd-602e77d2369a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ac5dee1e-fcb6-4169-b1c2-cb79e3816707">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_98f298b0-0d49-4070-a9d0-729a5d644edc">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e72e00bf-d396-4b30-95b8-4da196f3672f">Scheduled Study Location</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e14fcc67-aa53-4a9e-bd0a-d4c99fb6e6c5">(0032,1020)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cb5f5e9e-195d-491b-b8dc-a3d2e65b246b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3e6a17a9-3049-402c-b597-2b0365272e82">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5c11e58c-22a2-4967-a5d5-9ef924f495ba">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1bc39820-aa63-4b75-93f1-9e2fb2eacf94">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b49aca0d-e5eb-4668-a68d-3355eee2d20d">Scheduled Study Location AE Title</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5861bcf0-9795-4531-a6a3-4a6c61d2d9e7">(0032,1021)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_083e6e1a-b300-4b4c-a400-e81af0ac1215">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2635a689-3d8f-41d2-bf44-16297c71efb7">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7c6d6ccd-e84b-43b8-abda-98f63bd3e253">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d50aeb5-13a5-43a0-896d-458eea95a285">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c1246c1-f6a1-462b-bd84-e1ee3f44dca2">Scheduled Study Start Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d0ccbb49-c544-44dd-81e9-acddd4ee787c">(0032,1000)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_66bbe8bd-e039-439c-82d7-03ed8d2f216c">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e5e39e8b-aced-4470-8f9f-d0aafd83f10f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_68cc43b6-dffa-4bf8-8510-eed9fb51f9e7">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_270f86e9-f79f-4009-848d-44953883064d">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_032290c8-178d-4292-b180-69b8c5c183aa">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b80a9485-f596-4a21-a2f8-e7e0777cfec5">Scheduled Study Start Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_27d7bdb9-3224-4888-9850-d42e0bc64d7a">(0032,1001)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2ac95b4e-16e1-4dd6-a0eb-2da0c6471ed0">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_23aa01ed-db15-4140-bc00-0ca24f8791ed">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b8fd29f3-0b40-466b-9528-92c2cb861132">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_766e08e4-314b-40b0-a500-9b1bea5cdd5e">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3bb37f76-d292-49a5-a36f-bc1c318b5a40">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e859106-858c-45b9-8a54-3b035af35407">Scheduled Study Stop Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_75ae1c2b-22c4-4753-81b4-d0d0ef433350">(0032,1010)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0168745e-832c-4f25-b11b-dae0c2767c49">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_16ff3b77-20ca-4eb6-93a2-556b23590863">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f93affc7-d8a6-4eb2-8614-69fbaf951c98">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ed504f20-41ed-429d-98a0-bafe4926d9fc">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4ec20e9a-29bb-4dcb-9391-b9852bc16611">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f841c63-c278-435a-aeae-c7f2ee40b84a">Scheduled Study Stop Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2f9d2b1d-7b33-4224-8c07-cd065ce64a14">(0032,1011)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c89b3ea9-18fd-4240-980a-9931adf18736">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d6949c82-26ff-4994-a245-cffcbe92b7be">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f3c82a73-a963-4dfb-aa38-3ad550fb14e2">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b47a69fa-bc47-4b93-8113-6220fd94f9b1">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5596defd-3a9c-443e-be9e-b7e446296047">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36479a05-83e7-42a4-981b-e03b66adc8dc">Secondary Capture Device ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1da6c6e1-a53c-4687-aa6c-28f31dff3abc">(0018,1010)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_51b3d5c1-549b-4242-97ee-9a29c70eb63f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2f432749-37c7-4792-a302-86727bd0e811">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1e702bd9-5ce6-48cf-a800-0c8efec673e0">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a8b50801-f756-44b3-a081-cb3cd0c04b16">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_64be7804-4151-48e9-810b-30510802b289">Secondary Diagnoses Code Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8440f5df-874d-4af6-bfeb-7ff92d2bd604">(0008,1303)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9b478a5f-8636-4b3d-8da2-58b6f54d07b3">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a524d328-bfdb-46b0-bbda-a1b04a1856b0">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_602a4882-562c-4b01-bbaa-f3b055fe61ab">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1c0205a7-dd60-441e-bb0e-238c8d4d8507">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9641a45e-18ab-4f53-8436-27dd48ec250b">Segment Definition DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6cd58467-7850-432c-b3ba-5e0467a2b871">(0040,B036)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85fbf1a5-1b9c-4566-9b66-9aab1232faa8">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8a22eca9-9cc7-4020-9a38-ce890db27128">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fda056e3-afaa-4b2b-b668-e7ecf376e469">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_013f5e41-7b12-4866-b6ba-15a156bba603">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_62138c6c-3098-4121-9871-fcf9c6aa5fbb">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73d4db1a-362d-4af5-ab7f-02d0cd760594">Selector AE Value</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_27e11978-c287-4c83-8aa2-0ee72b3f798b">(0072,005E)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_52063284-f579-4e49-9a53-cc1a0aaedc76">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3b3e334d-f499-48a3-8395-9e9c16ae9943">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b0b0ffff-150c-403a-88f8-6598bf12f045">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a2e58666-2d30-47f0-9aa9-33a20aa665d2">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50823ea8-5be4-443f-afa4-0a33258df24b">Selector AS Value</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_70c85fba-2ec7-47c4-b8f1-87f45b09f86f">(0072,005F)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b06194fe-2462-466d-98a1-c6ea420965e8">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_384eec71-c713-48ea-8cc4-d2d9cdec2c84">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0d949d80-f55d-412b-a607-ba03e6ecc2b4">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f28836a5-e131-4bb2-a344-a1125da06248">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39b4a935-ff43-4a16-a3f7-bec6502356a0">Selector DA Value</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_40d75af5-a5b1-4990-a91f-1bb16be3a76f">(0072,0061)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2519dcea-a5f3-4d67-9772-2bb4c353b910">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5b21079e-5a86-4ebd-bcf1-c7dbbe30d1f3">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a53b9745-c7de-4830-aebd-714dcbc606ab">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d0e9e73a-4d89-4370-91cc-247e5265d006">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_58cfaacb-2445-4369-aa05-8d75d5660351">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0975a3c6-2511-4690-901b-82ec31be441a">Selector DT Value</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_43f07bf1-ca85-4966-bf2b-3439a44ddccd">(0072,0063)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_66f5d755-c537-489b-8d77-e101d93199ff">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cbf19cab-93e3-40a1-9dfc-40b762e2e151">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7a9a4972-1a16-4ac6-9394-25c8c762f388">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f022a9ca-a0de-4570-9717-f8e717b7cbf0">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_96553f15-a5b7-4135-8fe5-c10c32d08607">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b253fd6-56c5-41cc-9565-ceda99649dc4">Selector LO Value</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fa76db1e-d8e8-42b3-b14c-72aa452e3f3d">(0072,0066)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_229fc6b1-f830-4ae5-8a1b-1eb0d5cbb5d9">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3259de3a-0418-4e24-8037-42e3fa459aa9">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_913576cb-f0f6-4f8a-b082-5232c10b2e01">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85ffe712-bfc9-4422-8db8-27eea5daf1d4">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d32d8b18-970e-4d16-9a52-da9699906eb2">Selector LT Value</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_97da4fed-906d-4579-b3c6-88ec9eed8120">(0072,0068)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c3e2c63a-96ba-4344-b76c-0d6702097040">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9d34af79-1fd8-4d77-a432-a2e670efb1cc">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_68bcfdef-b1fa-4a2c-b140-964bb0402527">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f9e33773-37b7-4d27-858f-e5020b0732f6">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_16dd9b64-2e09-4515-a640-c2918aadea43">Selector OB Value</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e33bb070-390b-4b77-9cd3-221a9772cfaa">(0072,0065)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8b9353de-c7d0-456f-a773-8d2bd0966a14">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1c6f299e-5156-420b-9515-5bbbf83025b9">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_92082919-919a-4a8d-a787-2c16b0d1602f">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82d8cd43-2647-4aa6-a208-2ddc60b229bd">Selector PN Value</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_758aa8a0-ce34-4ef8-b139-29a6e7641612">(0072,006A)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_284cdfca-5b36-4b31-991a-81d39e4be184">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0ecc3a66-1f10-4cb4-b8a9-be9d34921a73">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_831fc4ec-b106-4560-8f22-e2b6df3994db">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43e99bff-d773-4721-869f-cce6d1049f95">Selector SH Value</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_64770ee5-a442-4a58-8d1d-a4d1d0224e12">(0072,006C)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4726abf0-0f70-4163-a3eb-f7094cc8260e">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_644ad4e5-b95a-4e76-a3be-2cb2bd1bc284">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_317f440d-4d1a-4337-8221-5a2262bf93d8">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_35b7d3c4-d36c-4021-9911-ff257ff93d92">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38097290-1e46-4369-9899-2d5e6b650d73">Selector ST Value</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ffdf6a3-95ea-4047-b444-0581ca5e8297">(0072,006E)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9c8d32be-14af-4f56-94bb-014e1f3773e7">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4b2e44a3-b10d-45a6-883d-7878013da84c">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_730408a7-6dd1-43a1-9d38-b45647586506">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e930f1a4-333a-4fcb-b6e3-0dc806b51375">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6f7162a2-a31d-428c-9bc1-e6eea4986df7">Selector TM Value</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b6e13596-0558-47d2-9425-a2ff7faf2461">(0072,006B)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7756448f-efbb-455e-8eed-d10889f4af7d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_769e901b-9028-4b89-a8c1-869034f4f672">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7b0fde4a-8a39-40a4-9e68-3a0b0ce73afb">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c3d7fea8-f89c-4256-aa2f-911fed6b6390">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d72c2354-fe5e-4933-b407-1116dc074be7">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4b4ea6f-bd3a-4eb6-9971-0860b7c4c819">Selector UN Value</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d04f4a3b-a199-4bd2-ad6e-10e8b822eed0">(0072,006D)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3cbfbf41-27ed-43b9-87ba-57c2b69bf9ec">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7471c54b-05f9-4b9f-b3eb-14d619935309">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_317443b8-797f-4ec9-bda4-30de114a6357">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1edb3f2-d6c5-464f-8886-a8fb70f21f4a">Selector UR Value</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ad05336f-ea22-4961-9656-b8c3f15a73a1">(0072,0071)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_44d54e48-e64f-4668-90a1-a331e7ce4165">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3494bce4-2624-455d-9638-e9799e110488">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8785639a-4c15-432e-a0ce-54323f64d762">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ae7fbfa-4174-4159-b7c5-0c185f757cfa">Selector UT Value</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ad0bf8de-a2a2-4095-ad60-501300b18a0d">(0072,0070)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_82f9794b-ccfb-4938-9db9-0979f9d8ecb1">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7f29b641-eefc-45c8-81aa-ff1d9dddfd6b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_576fb76e-150c-45e7-8877-f936bc5308e3">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_52d24eb6-9796-4c2c-96b4-742f2076246c">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c5d6bd6-e9ca-47fa-906d-2ea36935f768">Series Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7cb117c6-bf80-4c18-bf2e-8e0172246aa5">(0008,0021)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_abcc6a85-f700-4b22-b2ab-8bbf0b24d1e1">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_51250a09-7735-445e-b675-e79586e845aa">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4fc939b5-aa2e-48a0-94a8-f375a0dab707">X/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c3850d12-eab7-4d97-aa79-113f501e4cb7">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bad2b9c1-57a6-46fa-937c-75670d4c1cd7">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2be37aa8-d1fa-4b4f-96ae-f12f79db740b">Series Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_41b0021a-bd7d-4e17-a0d9-cd2a8bb3a5cb">(0008,103E)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_10adca7e-f967-443c-b9aa-619d8cc17cc9">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_16689d21-4390-4ae9-b18a-72774881070c">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_84c437fd-adc3-405d-995d-1c1cd22fc7ce">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9b0d2298-c0f9-4f51-8860-c530617a2f1e">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae9eba09-cce0-422c-8616-850255448549">Series Instance UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f704df31-49c3-4dcb-80d7-7296cdc40541">(0020,000E)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_146d25e8-6d6d-48ab-9952-c060c69374e0">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7d07422e-29ef-4ca3-975b-d94651a1a953">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_35f732fa-3ff8-4c5d-bb7d-305185abf009">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c12b0a96-0c7f-4cfd-94d9-a36e7ac505ae">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0dfb63db-c019-45a5-b7f1-9337ef842b01">Series Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2a3c5457-22c2-4178-9186-b8f625752cbb">(0008,0031)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e814f0e8-5aa4-4538-892a-5c84fdfa1261">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e77d2e47-ab71-4cf2-ae1b-42d0c584fbae">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c453281d-eabb-49e4-8263-403d24c48438">X/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_88123105-1478-4b9c-bd65-95e22bb2818b">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_61a73c01-beec-4cab-b4ad-e1b6c778d399">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b0ca15a-0846-4a26-b302-2e36cefd5e38">Service Episode Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4880fb14-474f-46a9-9e97-8671a2c20a52">(0038,0062)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_67add679-6d0d-48ee-b966-c985c9b70755">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_94a407ba-d643-498d-9631-f44df648a18d">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a4c7a305-1375-4731-a984-ca9c0878f511">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7374b802-ec2a-4604-8f30-309e43ca408b">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6635c98a-a00a-4ad6-9831-ed7684c84576">Service Episode ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0d2ab4b3-aeb5-48e9-9c00-f27baceedbcc">(0038,0060)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_78b61b0e-1422-4fca-b165-c412ab522723">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_82ac1a1f-44ef-469e-82d4-27c0c8e0422f">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_828e498c-93c4-4f27-aab1-1013f93e4a79">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65f915ff-d88e-4ff9-8f5d-8218210a8d32">Setup Technique Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cd62a8cd-12fa-47bd-a0c1-b7c34dc1387f">(300A,01B2)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_136bc8c6-e092-4c43-adeb-0d33f852e848">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_924f6985-5b32-4811-9a67-186c207d2157">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0379c0e0-2f6c-493e-ae53-ae0232659df7">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_492c209d-57e6-48c3-8f8f-a814594dfb4b">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf1eb94f-7834-47c2-8df9-b2bed110230a">Sex Parameters for Clinical Use Category Code Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8239be38-95d0-4c1f-87d1-1b49aaebc376">(0010,0046)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f25dc090-019e-449b-b4ab-bc86e92466f5">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fce4ec7c-25ec-4656-8e88-b0aced887af2">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4e47cee4-6c9d-469c-b503-7acf3d140be0">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cc3b4186-a66a-43cc-8ae5-9c6a12fe9fa5">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe120016-9149-40ab-bbd1-0838369ce6ac">Sex Parameters for Clinical Use Category Comment</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9adbdfe4-8b84-4912-b012-bdb56e3b99ee">(0010,0042)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1c2ad85f-f845-4a0a-a7d9-d88174640a9a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c5a6fdc3-de1f-41a5-9fbf-5dadc2ea4d50">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d761041e-3be1-40ae-95b2-e61eedccfe6f">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ae3caa65-e219-4dd5-8958-41165e84ea6e">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ba5436b4-d1b7-4c67-86bd-50db92183409">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_258f8340-52f1-4d2c-bed5-676fedb5963f">Sex Parameters for Clinical Use Category Reference</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d3f5e9d4-6e05-4232-9dff-56c709cd63a5">(0010,0047)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2df867bc-f345-4550-86c4-30ba8b5295ac">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_303fa5aa-ec32-42e0-9431-2f008d6e0c8a">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6b5a194c-6191-48c3-9ab9-02362cf51981">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_508e70b1-7a58-4056-835a-b9dcc04d7a3c">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54ad8dad-5ff4-4f3d-ae89-83b2c46233a1">Sex Parameters for Clinical Use Category Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_063212fb-d0bb-4606-b56e-4f625ac3c020">(0010,0043)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_35bb7a9a-ad1b-4a07-92d8-e49f3a7d3fc2">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_19139a51-d1f6-484d-b14e-45598d313c83">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d580d2a9-ba5e-4722-ba2b-089396998429">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dbccff5c-39d9-451b-a080-6826a646d7bc">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69edf472-af18-4190-921d-cca8c882f558">Shielding Device Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c9bbc04b-d7d1-48d5-b422-54a5c0d45839">(300A,01A6)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_44d27a6e-d2c6-4b38-89e9-828ea8f8a192">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e5c71cef-d415-43d0-a36a-7ff655c72407">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf8966b1-20fe-4016-9000-49e4c165d379">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e93fd830-61cf-4146-b5a0-1228086898fc">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1c1cbef-8f51-4f5a-9366-e0466be81063">Slide Identifier</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d3b54ec3-3bfb-4070-b386-857e4d4359a0">(0040,06FA)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cce05c9f-3e90-4034-bfcc-4e1eb63a2735">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7157ad15-a886-4e61-94f2-56648484c677">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_475a8b8c-e6eb-4bc5-a415-9411bd5e2dae">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be1a4a25-270d-4492-95a4-301dc5906dbb">Smoking Status</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d44b7964-704f-44a6-9262-b96dd6fd561d">(0010,21A0)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69d7f1cd-e1a8-4e7b-af89-72937069391b">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0dd7771d-f93b-4f24-8f4e-00c8f40a4ccd">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_12bed05d-85cf-4834-b5ef-d0313136224d">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b7cc6fb6-a624-431c-b228-580db5692714">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f6815a3-7236-4191-9e09-2f5a7a758734">SOP Authorization DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_12b44c35-f3bd-486b-8ed3-f54f0e89b228">(0100,0420)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73bf75e6-96db-4bdd-8d00-552fa4023f2a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a82c1e77-dd5b-46ef-a1a1-985fb3095385">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4f68e7f8-b4ab-4c2c-8e4d-70e27702047c">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0fe59d83-de80-44e6-9a89-3dbe387bd6c6">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2c54b8af-66ec-4676-ba83-e0501c857bc8">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea4a1ad6-3021-41c1-aad6-e25dd24c6edb">SOP Instance UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ad3a5071-5433-4568-9c3e-681f6a724c88">(0008,0018)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_448fe6cb-04cf-467f-81be-7023ec54d8f4">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5349b1d1-66c6-401f-b5bf-9f94ec835a39">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7a0822bd-38f9-4689-b577-c2150e7d3ab3">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0e0cac7e-6343-4741-8321-69ac0f3d3412">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1bc25b0-1d51-4e35-a9e4-584cfc18648e">Source Conceptual Volume UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ceb072ed-edda-4946-872a-0e8ecaa2a9d7">(3010,0015)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6fbdf1c2-0e3b-4469-a5b2-55349de4d5c2">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f8be66f6-f912-413e-95e0-d6b7f0839526">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0fa23544-4f7f-42b3-9d21-6c5800f8834e">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2ff4cfa1-f207-43d2-98bb-9bcc7a6cd196">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87376e0a-9820-4f25-b93a-2beaf7344039">Source End DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9c2c8554-d97d-4a7b-a407-61613a8fce26">(0018,936A)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_23ce4e18-fa6e-487b-9b26-f186f4babe1a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5052a3af-46b1-492b-910e-2c5b929959e6">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_584ef90b-19e1-4d04-ad63-db58719a1ed3">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_669c2975-abb7-4ec4-8bd5-d52e3509e54b">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8ccbe8ab-628e-44b3-851b-f859948ab77f">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d3d893b-1602-47a0-929a-e218a6f1b325">Source Frame of Reference UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_98e63114-8845-436f-923a-640301f9759a">(0064,0003)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_629fc990-bf47-453e-b463-22e7752b0cad">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf5a1fb4-16c6-401c-8445-ade6f5925873">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f03f9997-5f4c-4970-b97f-b07316d8a4c6">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a2df5f90-6c5b-48ff-82a5-b6ba006853d1">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ec513fe-05df-481b-beb0-15e0beaa11c9">Source Identifier</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_09a20ccc-f372-4362-bdd4-40d8f5e6b4bd">(0034,0005)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3835cece-d411-4788-a053-e6d76fe7a05d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0f2e627e-4b50-43ac-addc-65f051870438">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_139cad7c-3432-4a77-adbf-0bb972ce4052">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_760bb50c-a74b-44bd-91e6-f638f665d8c1">Source Image Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8ba4269f-80b3-4f2b-baad-404d2f4b0d76">(0008,2112)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_65701209-940f-4bb3-9fdd-d60ccb557820">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e6594fbb-23bc-4940-9451-2118449f1d25">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9a4687bd-f898-4ff8-a3f6-1d014b6f9567">X/Z/U*</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f64b9d7e-adef-43f7-974a-65506b1f7580">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c2192262-5d63-4e56-b9cd-0e63f4901064">Source Manufacturer</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9e2d200e-1d97-456b-b019-77ab33c09960">(300A,0216)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1dd29b2c-41c2-4080-8e2d-2a16db83ed19">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fc771e9c-b650-4c6a-8265-3902bf2ee208">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aa752176-08f7-4f11-8d4c-8d114cda205b">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_041e144c-f5bb-4e06-a91d-3c240f8a7cd4">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9f62b93c-301b-4b97-bb37-1d04c7024ea2">Source of Previous Values</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_19bc3fbe-5183-453a-b545-4e81d775f45b">(0400,0564)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_10f506eb-d168-43ff-aace-8713882d98b3">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e56463e1-f2b5-48c2-8b60-5ac184d39b80">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_25f308f1-9bec-443c-af39-dcf8736d4aec">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_edca0f17-3a84-4eea-bdd2-f4363a8c4284">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_412cc3c4-168a-4bae-bd5c-3935087786c3">Source Serial Number</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_63ca9332-e3ed-493c-b9b2-1f81517fa025">(3008,0105)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_caf166d4-2592-44f9-9d99-94975979a08f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_291b4eb0-1aa0-435d-a558-cdce203c9d13">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9bbeafae-501f-4db8-8d28-6ca3bc8181d4">X/Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4aa3caa3-cd87-411f-86d7-6f87c84c4bfe">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac3dc212-86b8-45a6-aa1e-e44a37c39f0d">Source Start DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9c9dd5bd-30fd-4fa9-b9e6-8f6625e0473d">(0018,9369)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a8245659-a306-4ee4-b884-1d239b5f82ed">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ad7e047d-eaff-441d-9f2e-1b9926378738">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_561ba3f2-a7db-4acc-a9d9-6323892159da">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e0b504ea-63a3-405a-910c-349178ed5d71">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9e3faf01-d8e9-4000-b74b-1b3285f2dabc">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_95093e9b-362f-472c-977f-e27374d5de80">Source Strength Reference Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9eb26dbf-4940-4d15-bc02-052aa1443d94">(300A,022C)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c27d8c4c-5e70-4f74-8efe-8374b1ebc40a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5de67635-f575-46fd-a4fe-608db4e6fa31">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5fa2ca66-1f48-498f-a65c-7586091ab69e">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_07df93c9-258c-480f-99d6-5b6b268b8a63">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_310dab75-2cc7-45c0-a92f-405ac05007c0">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce8b09fb-fbb5-42ba-9faa-b13a1e80ce26">Source Strength Reference Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7727875c-6ce2-47d6-9a38-5b06956d99c9">(300A,022E)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_59d93f69-facd-4737-82a3-8798b211ce0f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e127cfab-3d30-4be9-9a32-0ee23b5347d5">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0619d68f-4a02-4b90-bf1d-e4d53063e9e9">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_368a33af-e1ff-4dbc-adc7-c57135a6354a">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f96182d9-5074-4974-b9f9-e6f941e277d6">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_40085199-ce1f-4f39-9879-cbdbd1320276">Special Needs</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_51a5869e-c01b-4f9f-b876-12700182f03c">(0038,0050)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5de0890c-e41e-4f2f-a6f3-9de78610b56d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_627ec0e5-ab31-4569-90cd-58c5e452ca56">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bfc5c504-7097-4172-9c3d-5178ce6142f2">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c663afd1-bf29-4bfe-afa1-89599040aa02">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7562ec31-c5df-449e-9c84-88f6408f14bf">Specimen Accession Number</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aed8bf89-6fb7-4ec4-93f5-9cfb59b255e6">(0040,050A)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_144f24bc-3949-4ab0-98a6-760ebe0d9750">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6e00065d-928a-40e5-9456-9000d47ab663">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_91748836-c6eb-481f-81ac-2811440720c4">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_00862813-d334-4af5-8586-9ae627c97fa9">Specimen Detailed Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_34ff2674-6a23-4afb-a9eb-132d6e9d1a3a">(0040,0602)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_714b675f-4b47-48f2-8250-91571bfb9b85">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc3859f0-effb-49ff-a016-fea9a77a6a76">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_27fd6671-2080-49ce-afb6-4881d3238f1b">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3075cb33-5d01-4700-af33-a850f76cdd2a">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a86d747-5745-468b-8c42-83cfaed8cdc9">Specimen Identifier</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3e288c8f-3bda-43d6-b96a-dd6e8204cd59">(0040,0551)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7a4de436-30c8-4730-a1f9-bb82ab70ed26">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_81909ddd-d642-4bf3-aa33-29caf8871943">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_af784128-184e-4fe5-b0d8-02a60bb3bd50">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_23b304a6-164b-410e-835a-5151756bcf70">Specimen Preparation Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_feb26ebb-e99b-4f29-a7ad-d9494869899c">(0040,0610)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_56ebf79c-f271-4fc3-92ed-c54c7454246a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fd2509a8-7582-4385-a5a0-04737c84f2eb">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_98354bff-a1eb-41e8-9c3b-3c9556b8a369">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e197b5c1-081f-4f21-97ee-e22d26abb6fd">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54dc12bd-594f-409d-b14f-0af111431299">Specimen Short Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_578aff43-b8fd-455f-9a3f-76ff76d79bcc">(0040,0600)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_23b83cec-cfad-4680-afd5-5e4b9b437799">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f53744c4-7b3f-4cd2-8a39-65309907803f">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f0c0071b-8b56-4aa1-a128-ffa1cbc81bd9">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_961a2b0f-683b-4ec0-85c3-430636dc0505">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6a7924a-4179-4cb8-b2be-654c4aad93d9">Specimen UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d676ea48-ce02-4a7c-a60f-161caace1783">(0040,0554)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c821060-b77c-45bb-beeb-5de40e248af1">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_703075bf-c8da-4f3f-8294-c462233dae5b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f4ef8441-240b-4230-8c28-0c1def485f02">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4bf9605c-bf1f-497f-8c4c-866d412f0e77">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2188bafa-574d-4a69-a431-bcfd7cb32653">Start Acquisition DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c07790fe-3be1-4164-9d10-6f45280e9ebd">(0018,9516)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_53e25a3e-6acc-4c72-8ef4-2cf7aaa01b6b">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_29905d2e-91e7-4460-b91c-2a9485171b68">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d9fe8037-382f-401b-8f69-58f0db9c6d43">X/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_356c7184-2610-492d-a905-8ea60bc488f4">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb5c5e7c-84e7-49c7-848a-c22644db62f2">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_58086b58-dd3b-4dff-a9b1-11de96bc069f">Station AE Title</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2ba76249-9fff-46ac-a3b4-67cd049d8cd9">(0008,0055)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7853758a-a3f0-43a7-9933-7e0f1f8afb5c">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_21a25890-d5d3-4a16-80b0-2fd16d8d7c0c">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b982137b-217c-4365-bdb3-120cee49d5bf">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cdd16d95-bad2-487d-9e0d-25ff905b0585">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61f4de2b-a12b-4284-86c7-626f03c7965b">Station Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b8fb1a49-ad81-4901-bb31-0455b3c8a3d0">(0008,1010)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_97830aab-aed9-44b5-a563-f048d93b275e">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d574a8d9-bd23-41cb-a421-e8a3e8baa7c4">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_76dff185-aee4-4721-8fa3-b134df0a231b">X/Z/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a8e38873-f2a3-4ec3-b649-1ca28b6c97ea">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e4134ad-1480-4cc3-8a8f-6108de194f98">Storage Media File-set UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_44e573cb-db89-4f9a-9ccc-862da53493b2">(0088,0140)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3917b5d7-9ff4-4820-94de-8bb3d2e40659">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e4576f71-77eb-49f3-a152-7013bf4b02da">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_431cdbd3-c6ba-41e2-a852-134c9dfbff63">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f22ed82b-c291-4b54-b26e-33f5db2e1b7f">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3cdcb107-f294-4ac2-8c2d-4246fcd0b881">Structure Set Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6530dc3b-09a4-460b-b5d8-5cb8b4a8b4f9">(3006,0008)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_338212d4-01d3-44d0-a67e-c6394ac04562">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b178dd11-afab-47cc-902c-cf81cc676b26">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b5174f47-4c32-4b31-8f4f-4581df7739b6">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5a542f01-af57-4ab1-a707-48bfd71d39b8">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a952966-6d9c-4576-8bcd-5852609ec099">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_181a735c-4030-4064-bf1a-557456be4217">Structure Set Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4469a345-a6a7-479c-9204-9be149b718d6">(3006,0006)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b1e7d8f0-8d5f-4463-9469-83883ef5de65">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_68259995-a36d-4335-9aad-aa6f1aaf6c35">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4be1001c-5929-435c-8bad-8e8d50a1017d">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9171dd54-7708-4c42-8e12-29cdb2eaf20b">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fdb77569-5643-4346-a9a1-fd192619bf55">Structure Set Label</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69bc64c7-936c-4c76-8d42-2715a511ea8c">(3006,0002)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a201b799-8039-4bcc-8cd8-6e5bdc559df9">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_44370ad5-1cea-4285-91b0-9d2a792af8e1">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6fe557e2-5bca-47b5-be3f-3200ea5eb3eb">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_38653e9e-7824-4729-937c-aa37fc2135ab">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e5e5d5a-d882-42de-882c-ae7b5b3f0431">Structure Set Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bd103a66-6698-445f-bd34-d6c0c8f2d975">(3006,0004)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e0f4be4c-94fc-4962-934f-d0beaa03f259">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_05d9e4ce-18bc-48e1-a330-1127b5355b6b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_42df5111-e230-4423-bd99-d31158b0ae84">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e6ad4054-a05d-4a9a-9b44-6bd9fcc8fc9b">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae318e99-7013-4884-8720-f76ae0092d92">Structure Set Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e77c2d7f-721d-493d-8680-f25371db7e7f">(3006,0009)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_61e7ac78-f682-4f78-bad8-8b5f4d2a3744">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_97c32055-39cc-409f-be8b-2db82b7cd052">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ed9d0626-8d82-4db6-9963-3756ed26f010">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e917f757-3806-455d-9455-bee8c992dbdb">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_43f2fc97-3b0b-42f2-99f5-4865033753bb">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a787c08-0e13-49ef-8fb4-7247ca1660cf">Study Arrival Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5831d3a4-8d5d-4d71-8af5-a7284dd87436">(0032,1040)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2a2a6f2a-9261-437a-b713-f8594feb8ab9">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4f31ee78-d1dc-4fbc-8d59-5e16f8774c0b">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b8510ee8-b619-46c6-88a1-073ca20d9809">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f8d340e-f731-4cea-a98a-72fa3af5cab5">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0e27ed70-c345-4984-8648-4316dfe13750">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_25326e6c-55ba-4ec8-a572-5f1bebed99f2">Study Arrival Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_02fdf0ad-95ab-4cc4-8529-309da1c9cc1b">(0032,1041)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_714d57bd-57fc-4c53-b876-2ca787a3168b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_580b61a0-0e73-4ad1-9c73-3a9f1b6a7752">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4af1f744-b18b-455a-9690-f4fd6c55895a">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_edf91dcf-22f5-4af5-93f4-e6dcd4c4c856">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d81f6d13-923f-438f-b1ae-407290f4a03d">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fcc05f68-cd94-48e6-b507-2cfe00f1b9ec">Study Comments</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ec77ba1f-bb9f-4bf3-872f-51935a6d5c8e">(0032,4000)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b7024483-cf32-4081-a0c7-00c6a5e27bb5">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_89b317d2-36ab-4fe5-87b0-ac1e0e5e82ba">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bf3436ac-a789-469b-9cbe-a994510793f6">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_191224d8-4018-47a3-9596-cbd3678b1fec">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29ad1712-6eaa-44bd-a85e-496e1635b75b">Study Completion Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ba3099d-e67a-47f7-ad0f-9becf35ffe25">(0032,1050)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d0acaba0-c28b-4406-94ad-fde3c0c875d3">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2db2552b-9192-4e0c-b3c3-84dd30a9ab04">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a2901d80-6bc9-4cd6-8795-9d48c2efb7e1">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_54580188-f2d5-4b3b-bd28-33f8e1c8fd6b">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d46aa17d-8115-4e67-ae94-7b96a580eed4">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b24bf8fd-9ee8-492e-bb27-293d5161f510">Study Completion Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_899882c4-6c49-46e3-9864-300cc225023f">(0032,1051)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_002da342-e085-4ec8-a61e-17f98334dcfd">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4ebaeda6-4a07-4d6e-8ffe-84441bd00ea9">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_04d29b35-0872-4c42-8737-ad723b6e58e0">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_93d66e63-45bf-4111-9b54-d70d993726a0">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_389d47d8-4852-4b40-9125-e21fb3a4e2d5">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8f7693a-4dc0-4f92-8034-62bbb484a5d2">Study Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bf511f52-b3ca-4686-9a74-97f2a9e8ad39">(0008,0020)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_994c5916-329e-4bca-b067-2172bfc41c5a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_acc9c7bb-7959-47e9-8029-e930b3078158">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8074b3dd-97e7-400e-bd8d-0a04a25adaf9">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6e052096-3436-44a9-91ec-b8a4b546cc9a">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b83220c2-af2e-4fe9-9cc3-316b8395de24">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3617477-16d7-43f3-9706-f945f1ca4a3a">Study Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_103130bb-8301-45a6-95b4-4ceb2932e14e">(0008,1030)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7200fb8f-b080-45f6-b2f9-5caa8fce225e">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ec651f1b-5e36-491d-84a4-447cbaaa8ec1">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_58254606-a1ac-4d43-91d7-194acaef09ad">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b343fe04-63ea-4c8e-a718-58009287e7cf">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e2aaac8-7858-43d3-959c-55174e37c158">Study ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cd6a88d3-bf2c-489e-8d8e-66261a739493">(0020,0010)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_90487a24-7404-4418-8555-2623f037f219">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e27b3f0e-a202-488e-b311-70a2cbfe467b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d7cac751-148d-4148-8fe7-101adb728e3d">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e541ff8-c123-4cec-88bf-2c05ebc5cf0d">Study ID Issuer</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_70f6a399-b584-42c2-a5f2-89278f0e95ec">(0032,0012)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_623f37f0-febf-4eca-aef6-6442491d1d30">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ef4b158d-5659-48b4-b868-f3be937465fa">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_87116678-c8b9-4e6d-8a26-6182abf5dc31">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b49c81c9-3c07-4400-8c88-5786428c0e47">Study Instance UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f9daf3ea-ba20-4b09-8cdc-8e253b934412">(0020,000D)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9c5000bc-6682-4308-90bb-2baf3b7c3246">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ee46b6b7-ac34-4596-8f61-55b821811e75">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1a58eeb5-f64b-45a6-a2b0-b91ba994d3b3">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9bc434fc-ff2f-401c-b9d7-78bf059bb202">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a1c9b911-8b26-4b26-af5b-a5e29873e967">Study Read Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c5340ef-ee3a-4c54-87a3-7fb4ad711f6d">(0032,0034)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aea701ff-a390-4a56-951d-4a2dc9e09b15">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0f6cac10-2b0a-4b11-b49a-5e190057032c">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c2f6b3a9-f0b1-43d7-8c24-470c6cd34ead">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_51e56fce-2a76-4190-9224-b9dc60d1bb70">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_861f8d9c-9d76-4074-a3dd-87853e8ee5bd">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f804d663-83c9-41db-b73d-23eb19401990">Study Read Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6bcd48cd-074e-4639-99cc-ed842509f85b">(0032,0035)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4ea78e1c-2996-4492-ac59-6f353a0f01b3">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bb6dd0b1-1cc2-4eaf-bc77-739d81d1970b">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fc4abc7e-c57c-45fc-b35e-f4e3b7c146bb">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ab1c557c-cbfa-4223-866c-2059d76fabe9">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d75d9203-f6d7-437e-a0db-2344b863f94c">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3cb9c49-996b-4355-9510-d866d2330c71">Study Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_006be4ba-3e76-47c0-9d47-5af5e6d1ee13">(0008,0030)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cd70b7d3-4866-496b-9734-33d4361fc955">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ea0c05a2-8819-495f-9547-162d5687ac43">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9e37b6d2-23c1-4665-976d-c58a8b587662">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e220d517-4ed3-4836-bb99-72d3ff3e470d">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_25417a92-2f1b-4d49-923e-c485af52e510">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1a0012f-678d-4a70-bdd8-c9a556bc97d6">Study Verified Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b8cea8b1-ef56-46c0-9d66-701e0afe421b">(0032,0032)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b8c96d15-1557-445a-9e42-996ec730e81d">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8f6d505b-8f31-40ec-ad7a-2e9cba1a1495">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7e9ba8d9-2be2-4ca2-91cd-576898ca7ba2">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf0b7156-efce-4de9-9a4f-4eaa88e44543">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_be53e4e8-8237-4db2-be18-2a1d705457c7">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7a14fdc0-8495-48d2-a877-17ee930496ac">Study Verified Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_934ec005-e1d2-47e8-abc5-632a45e4571b">(0032,0033)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_07b28fd2-f890-47d6-b06b-c366ccf7923b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_83111e7c-2a7f-4edf-844a-6570612429e4">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_30f2f659-03d4-4aaf-8e6a-c77f0934ec4e">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d030f735-ca86-4e3c-ad42-8835a4b68886">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dd220b0a-ca62-4b81-85fc-fe123346528f">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5b43686-9f94-4e2f-b590-e3483134a225">Substance Administration DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1dae091e-58a8-4518-b27c-bfe2267fc0a8">(0044,0010)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_38c6604c-cc9f-4b79-91ae-5d012ac0dfa9">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f5b9ed77-0803-43be-88e6-4c9f673b9611">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b594c241-149b-40f9-af80-17a249adab5d">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8174346a-82f8-4454-b0ef-aed3b990daff">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_581dce44-ae3e-4b3f-a8cf-af1e9b992a89">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d3fe3f1-37af-4ca9-8fc5-25bf0772d454">Synchronization Frame of Reference UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_23935132-df9f-4694-89a2-85f8928352b0">(0020,0200)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_32ac4e51-ff1e-4eaa-a859-36e1bd444237">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_64177037-acc2-4218-a6cd-4cd34bcccaf2">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_97786abb-c04e-4aee-98bd-88aa731c5327">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a7e2da6d-a078-462f-aab2-b2304d104a63">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ab684af-2454-4ef3-90d9-594389929707">Table Top Position Alignment UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d30e2706-e1c6-4bd2-99df-bf5b6907ba8b">(300A,0054)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_585ff533-3caa-4cd0-b799-9c2fba247e5a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6b770e8c-5bbd-447d-a92f-45620d4614dc">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8ac04522-835e-4378-851b-3bf7e6611a23">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69dab220-1373-474e-b0e5-524709ed0232">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08742aa3-52f9-492a-8d80-a55b7cd29602">Target UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a94c02a9-1f8e-4e48-80a9-7bd77d450aa2">(0018,2042)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_21ceafd4-2c13-421e-a88f-eb9f921b9e11">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9f1eeff3-2157-435f-92a8-6bb8671abd54">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_06a527aa-5e8c-44d3-b425-55cf7809e37d">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7ab2d2cc-8320-47ea-bdc0-dc6cc12148d8">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e443611-0382-4bc1-8f09-9f3454ab8a3f">Telephone Number (Trial)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_216975b4-c49b-4076-8d7e-81022e490363">(0040,A354)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9c282924-b152-4cf3-afca-3656ff52c3e2">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c76041b8-efea-43f9-82b7-f0df983cbe12">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3529e812-5822-49a3-959b-b6c41f9f6da3">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d86b36c6-1b70-4024-abe5-88c665999b8d">Template Extension Creator UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1202b4df-d57e-4d68-a414-46023d9141cb">(0040,DB0D)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c6e9af32-c920-4181-b92d-c76a129ccc83">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7ea61808-a931-47f3-b79f-b57c433c7e73">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2c7f4076-f03a-4bd6-bbaa-f38fc2c1daee">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a56245b3-578d-4321-bdda-501e91e2db89">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5543518-c2cb-46b0-9705-6411c861ccd7">Template Extension Organization UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3c321422-f352-460d-8676-2ee31d0cb69b">(0040,DB0C)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3aa772bc-8bc2-4b8e-8998-82a11fc836ae">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_264bf3ad-f725-45a5-a458-153af575e467">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_897169de-5e40-4050-9a4e-761991aa991f">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9f2852f5-7fdf-44d8-87b1-ae7ff82e27e1">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6acadef-9fe4-4df7-8256-349ccf61e12d">Template Local Version</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ae7c4dc3-a290-4503-9c16-a0744b1f0194">(0040,DB07)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c8f3f01-9165-41a3-a7d7-a2ba602eaefb">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_375375c5-9b68-4956-ace0-2559e9199f10">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6f4dbba6-7d37-45b1-bf34-2586d053d7f7">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_20c55311-2906-4cb7-a43e-2429f774d683">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aeeab6b8-258d-4a00-948b-bbb238b5d3bd">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4d4950b-4900-42da-85a9-970002beaff8">Template Version</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2b02029f-5bb7-45c5-aed4-1d3a9e8bb761">(0040,DB06)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf318033-1353-4558-a90e-57a52e276eb2">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_736f8e76-e6d7-40ef-8dd9-4fc7c70d01f1">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cc592447-c70a-4d11-acd7-2a70084b67e6">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9ca06dbd-2d03-4e6e-9d5c-d35c9dcb0df4">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7662d786-1ed1-4363-99e8-d9caa838cd7f">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_db497d45-5c18-454c-8fc0-240b43bf8aae">Text Comments</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6b0677a0-82ea-40d5-828c-9d8b8274b2e3">(4000,4000)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8c2dd5ae-55a0-4cce-8970-616a5fffcf1e">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_57328e6d-d044-44c9-aa8f-dacfe98c1003">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc846ac5-b3e8-4245-a264-614801c2e5ad">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2914ff3e-0eb5-4b04-8b80-a21329c95a62">Text String</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_521c7fef-fb66-4657-a64d-3a97b0b21efb">(2030,0020)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6bd91aa9-fb08-4101-b125-26dedad7f1eb">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a7939531-82e1-4ece-8b80-cba2e2753f26">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_31715f61-185e-432c-aec2-a92b5cb15d29">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3917613c-ed6c-48a2-b705-1504cb322864">Third Person Pronouns Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dc8af55b-4b02-4d5f-a2b9-ae4c873356c1">(0010,0014)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f9803725-4a5d-4fc0-816b-2695befad941">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2385b868-7b7b-4d79-a3f9-d407d783394b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c80f4438-34a7-4452-9369-90912927975a">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a3587d8-31d4-4089-a006-347b85788c57">Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4fee3d4b-787f-4c10-8375-093914ec1bb0">(0040,A122)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4ff657dd-5520-442e-82ec-aa3ae4e26904">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8e0a6b75-71a8-48aa-9c63-da9b0d5da125">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_48f92671-f4b7-45c2-8ee0-c76daffd6ac2">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ce49ea7e-69dd-456b-9853-7b88ec83862e">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_782ed64c-e9ce-4721-aa7e-ab845a59945c">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff2c1e4d-1dcf-4bce-97ff-769a6982ab4c">Time of Document Creation or Verbal Transaction (Trial)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_18a87655-a2fd-4370-aae0-f597eeba8921">(0040,A112)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_71b3bb88-6668-4e68-8f5f-467c5f0ae0fd">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_15370749-3c17-4b2d-8945-7feb7c1e55b2">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_09f903c8-ba0c-439e-8953-5f5fc7b18ac1">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ac37817-318c-429c-897d-802a01958899">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_21f8a99f-84a7-4bf1-91d6-60fcb9338a4f">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4f90b61-9fb0-4618-855c-f5eae3c4962b">Time of Last Calibration</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e1a19340-e7ab-4048-985e-1a0dd341dee9">(0018,1201)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_172092ba-03c1-4e8d-9c7b-918b942944f0">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3d6ab27d-0d12-445b-866e-39b891a81fb7">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b8061813-6988-436d-9cca-1a9b0e23fd6f">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3a8df2f1-f4a5-4456-a144-ae02a93414dd">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d45ddf01-5b21-4d0e-8cd3-9f29c8795c33">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_595dd0b1-854f-489b-a725-3605abe38265">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_695b23fd-65c7-4e37-8964-97eac9eb45fb">Time of Last Detector Calibration</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fefe0243-26da-4a0d-8be7-d999fbe597fa">(0018,700E)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_73b31704-4005-490c-92e1-d3d1e603f2c2">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_03161187-2dc1-47e1-9eb9-0f13d9bfa52d">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_992f0ace-6e9d-49bd-a67f-e886de35f293">X/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_89674865-ceb3-44d9-a85a-767e90ac3793">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_09389d2e-f8dc-4ed8-8500-a785f78efd9e">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_03a4cf9a-021a-4835-b19e-1ccae9a07d2e">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9994fccf-476a-423b-ad1c-86ec0226a3dc">Time of Secondary Capture</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_528c1bf5-5576-4156-96a4-c0947788cfa7">(0018,1014)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7860727f-bce3-41b5-892c-ed1cf0db1ded">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2900b5a2-1fc8-4b6e-9d85-434a74d76259">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_794c5483-df74-4852-ad86-3cdc6d6ccfdf">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_94fb482e-6b73-4bf6-99d6-fb5e0c045c1b">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8713b9f2-b6fd-42b7-a89a-4d7402e21593">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_107cffde-14bb-472d-8c9e-2071f07e1167">Timezone Offset From UTC</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b9eb68d9-3ddf-456b-8653-95a51982f3c6">(0008,0201)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a02dda7e-9c56-4412-8bfd-04d444459c9f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_44e74044-0305-491d-8e2c-360dc1e8656a">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4911bbaa-e5a5-44ae-a270-27ba19f3980e">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0933f5b1-280b-4738-8a54-752d52cb1c86">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_793f3a05-cb42-4a62-a831-b5459cf7cd33">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5babe808-c42a-40b4-836d-da599b9b4941">Topic Author</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_61adcf16-d32b-4f0f-9338-7300d8f07f45">(0088,0910)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aa3eccce-8aa6-4e61-b5d2-8169087c9000">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_37b4c6da-c430-4ea4-92f0-c0b2aab09d3f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2021e5bb-923e-410b-9bff-7f40b884bbec">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_575bfb26-b8d2-43d9-b42d-75b2ccfb6ae4">Topic Keywords</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c93e26ff-c33a-4977-b36f-9a151d19a8dd">(0088,0912)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c30e0f96-aa56-4f77-ad0e-cb4534cb0a74">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_316df0d3-8d1d-49e6-952e-190145ef0328">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a766293c-b184-45d1-8208-f167b27797f9">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e2c89ba-5a27-42be-b39a-e78123a44c6a">Topic Subject</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9a9a531f-5afd-4827-9698-ac10752faba8">(0088,0906)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_32cca557-0612-45a7-85e4-c7b4f84c706c">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e2027f1d-33cd-4459-828a-d8b3aa726f88">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0d6eca5f-fb4f-43b3-b9a0-abe1df1ab090">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b957ee8a-29c0-4443-b4fb-b82cdd6d9482">Topic Title</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4812ca42-046f-4a52-bb2e-244b6be16914">(0088,0904)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_70c089eb-a865-4ae3-b61e-19e1355ff858">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e299c72b-708d-49b1-a3ea-f3603f6c7f41">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6a097d20-c702-45cd-b799-ea34c15a6153">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc0bfb81-7ef2-49d0-90a1-29d6a79514b6">Tracking UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e6f90a5f-acdc-4455-9bdf-5f715047f1d0">(0062,0021)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_60a7efaa-39a9-44bd-9103-cc1eff79289a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_64ad86cf-b568-4843-81c7-a2e0d8c0e1f5">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4c532826-88e9-48b9-bcf6-3a0049ba6fa4">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1b046899-00ff-4d51-98ee-d600ac413e49">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61cc3ff5-fbbc-4323-8506-912dffad9e17">Transaction UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d294045d-7be1-4bd4-a460-22517e3265e0">(0008,1195)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5abbd2a7-0d37-4a2f-be7c-ae2ed5624313">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_32b4d281-ae92-4eaa-87c5-e35ab0b674d8">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4bba59d2-38a7-4b4e-b11a-d8cbf5884bfc">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_65c7fd1d-cc1a-461d-b1e1-6a03b55bed02">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dfdf29a1-6d02-4139-a7d9-dc1373444595">Transducer Identification Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_38d66924-dc82-4af5-b860-2a4a0734d5df">(0018,5011)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f98de358-b64d-4b91-85dd-eb40a6bd28c3">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_86e600fe-cc79-4d82-b813-012e6cbdeb72">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4cea545b-87af-423e-833f-36c908b8fc55">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f53e310e-f9bb-41f5-9895-7e15b1444c62">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e6253d73-692a-4f27-b0fc-1b423d30c22d">Treatment Control Point Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4ee8b28f-f939-41cc-a690-35b6957f2650">(3008,0024)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1cd7140d-44e0-48d7-9c34-4fbd55a1e22f">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_045574c8-3cc3-4ab1-8f24-2da088581341">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f0b28d13-3c9e-454b-8085-7779bc9179d6">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6299dca1-d387-4edc-bc50-c9cbd4ded30e">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8b67d0c9-c754-45db-b0db-879cadad7df0">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85b5fab2-fc95-453f-acf6-15a6bcc69138">Treatment Control Point Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c13c149a-0e51-442a-aae5-e84f69374ca1">(3008,0025)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_71a840b7-a8ab-4217-beba-2096d95efaae">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_861b204f-3834-44e6-a597-569645dfdce0">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_581e2b13-c9f4-4d7e-859d-bc2dc8737295">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e408cc71-eff1-40b8-8cee-3fb3b7e88bb1">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_31ee5458-336d-4d50-90f0-3ff56cd5936f">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf89192f-eabe-4789-9110-07d7957a9199">Treatment Date</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0a795fc0-e3ac-4084-8b64-26f3d576f70e">(3008,0250)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3164b1a8-07d1-44d5-b445-e4e02957eb6a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fd6ae41d-3fe0-4333-9ec0-4fc3ae8b53cc">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7fe1753-38eb-47d1-adf6-a511daf4ba13">X/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8164700e-3263-4513-99a9-eb0df5cc58d6">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d72d5e1a-451c-4e94-bc0f-45b0e6454b42">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92f5f995-ff1a-4e44-8e58-1a5eab815dad">Treatment Machine Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_30982815-ae90-4cb2-a105-71187fc6fb9b">(300A,00B2)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf3b1d10-61ea-4c1c-b190-afebecf17102">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_98232081-2ead-450c-bf6c-4dc2768fcd14">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_35e259d6-257a-4aa0-b176-853e8c876eb3">X/Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b97ada71-99d0-4f63-a2e0-aefa869543ab">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f643a0e7-4870-48e0-a2f6-973833dc69d1">Treatment Position Group Label</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e9e9d5d4-b190-4792-848c-1d3772159a17">(300A,0608)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8874dddf-c67b-4651-b27e-7355d5d2ecd2">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_615204c1-7810-48be-a708-6ef9ea058b83">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_656be82c-d212-49a3-a813-e0b2784c2dfa">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_232228d4-798a-4682-b2a6-598c4e1e3001">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4bd1de86-df46-4ce2-aa77-08615fbe8253">Treatment Position Group UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a7e3e30f-d42a-4b67-92ba-3a85c258a9ca">(300A,0609)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_65f4b0fc-c1ec-44e7-989e-7535fdf09b8d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c60cc37d-6d41-43f7-b319-4ceea303fb84">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fdb676c0-5a14-48ad-b251-4e943ba31c6c">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_be34639d-61ec-437f-a598-e167fde8b242">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2bdd2a79-6f9a-470e-8227-a60eb50ae979">Treatment Session UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d394722c-6d5b-490d-bcde-2e7ee5c2ff03">(300A,0700)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d7fa0bd-fed3-46a8-96e2-a7e66cb6f543">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c89c687c-dedf-47c8-bd62-d682a07dd47a">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a6f94414-ae16-4029-ae03-923b520054d2">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4dfff75a-4050-46ba-a858-85fab09cb052">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57d6499e-2595-42e4-95bf-e19294b2e07a">Treatment Site</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_37368faa-f1a3-4e7f-9b76-98a16bd2596e">(3010,0077)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b7f2b3ab-8788-46d7-a208-56f501d8ba10">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0aec072c-bdf9-4820-a36f-5b39dd9abd08">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d9a2faed-7067-45b7-a755-f443d1ab8057">X/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0fb5f9db-6c1c-4301-8394-83f5c843a9e2">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3b49917-300d-4331-a57f-5368a83e8c6f">Treatment Sites</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_570451a4-02e9-4272-8f62-129e9789cf24">(300A,000B)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b1f58db1-12be-46bd-8d47-86d405a62715">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d65164ee-1593-4cba-94c1-b43b6a5f18d0">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1f87ca31-4322-4c01-8429-e7d0558b14cd">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0d20eb40-e141-4578-a6b6-4e2a7fd41ebb">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a72eef6e-3f60-4791-87a8-01b34da0742a">Treatment Technique Notes</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b70d9413-c9c1-42b9-84d5-83de0b98cc96">(3010,007A)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0df62252-0a11-440f-a2cb-2d338b793bf5">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ea7db8b5-3bfa-4065-90e5-de6a9c882435">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_39185bd3-0cc9-4b17-9737-ab98befa4ca9">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_34c19749-1146-4ba7-be50-e6194c714df6">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6d6d59d5-0826-47fb-8476-38bd145d8b98">Treatment Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0c9b1160-2d0c-4801-b9ef-34cb1e41a8bd">(3008,0251)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c3e23e12-2193-4d32-ae13-e2199ea4bbca">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_10766a0a-c72b-4a75-9866-73848aa9a287">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bceff3fa-efea-4fae-84dd-144c289056a3">X/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c359b475-6360-4139-a971-52f8b34f3224">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cb37cc39-cbf7-46fb-9732-6890a63b35db">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5f77063-d63d-4e9e-89e1-945fb62a3f5f">Treatment Tolerance Violation DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b95f34e0-2eb3-45e5-bcf6-56962454dcb9">(300A,0736)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_88090814-6979-421c-a0c7-828370ce5c71">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69dfca5e-6baf-4ff9-93c9-e5b2dbbda2c3">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a29791ce-dc74-4a05-a6c6-f903861deb15">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ffcf954f-3d4d-4146-9a6a-2d32df512258">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_48d68fc9-d4d4-4f3c-bc6e-68da6e17e4ac">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7af8e4d-8cbc-4b4d-b18a-a8c8742abdff">Treatment Tolerance Violation Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_97de1ed0-7104-4d74-b489-9d923b709f9a">(300A,0734)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a8a8e1a6-0afa-4b0f-87d9-c530f5a0108b">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_74e8cf74-1841-4346-bd49-656a43f98c6b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1f2909e7-df7b-48fd-86f4-77f59d79e5c2">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_82502ce9-fa25-4324-b782-5c5bc735528c">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_66ea0efc-58b5-48d9-a146-4ac31ba224a3">UDI Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a5689175-dd20-4fa6-a8e0-3c35e6bcc02b">(0018,100A)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_23b5a101-9c51-4ac5-8442-5b9b22a389e7">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_33b13891-1407-4165-aed9-44628a71c817">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b2a6257e-d07d-4526-903d-87d46c190502">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b3b2b76d-28f0-44f4-8f26-97fec81c687d">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f6f0891-1e2d-4053-966a-bf92354335d1">UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_caa0d570-d3e6-4a02-991b-15d2c190447b">(0040,A124)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c6584503-1354-43b9-aff7-dd0292cc5817">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_48049751-963f-4a0d-9415-fdee665efea6">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1c2b3686-7d6f-43f2-91f9-82f0004f8bde">U</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54ae3e43-aa8a-4595-ac06-d9491c61d530">Unformatted Text Value</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d01ba21d-449e-4752-8807-2ec4c2f6e073">(0070,0006)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_69bca0e8-d8da-4c35-87bd-6c019b507c62">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_972f6572-c0d9-4ac4-9a8a-10bef95683f2">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3f109f8c-1a94-4132-b4c8-9132024b05bd">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4925c96d-face-4ab5-847f-213dae8b5cde">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd5025a8-0ca8-4c99-8bf2-9805db01d6b4">Unique Device Identifier</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e9c760ff-71bd-414a-97dc-84fdfdc8df88">(0018,1009)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_37b32739-90c6-46cb-837f-f3a074934a1e">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_83df45fc-d086-48e8-bdfa-f11a586b829c">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_40cc7817-6bf3-4151-9cab-376b0866b740">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e2111621-ff31-4706-b230-4e48064a0dbb">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37bdd0a8-1a40-4891-9560-1395f0f28003">User Content Label</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_10066ecf-f7f8-4a0b-ab44-fd4645a85dea">(3010,0033)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cc1c14aa-6cfc-4a7f-9925-8d3e8e98b7c8">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_79e7c4e0-d637-44cb-b69e-808e1d56abb2">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c75a32b0-e87c-44ca-9f5d-873b0e60474b">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1663273c-e361-4485-9a36-e07ec2543caf">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1aecb2a0-4ab8-4be9-aee8-d9644b8d180b">User Content Long Label</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_281d6638-a95d-4c8a-96d7-e7c327397566">(3010,0034)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1e15d75f-fffa-470a-be04-ee71f7146714">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_094675da-2d80-4d9b-9f40-54770533396a">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_874e829a-0672-4cfb-8de8-69ea663e9bc5">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_067e15de-a3df-4971-8259-eca23e4d5e07">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_207e5723-8da7-4ad8-ba38-77e43f450c03">Verbal Source (Trial)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cb8c20a6-ccc8-4688-9e58-1b1b776d07ce">(0040,A352)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2430f447-0ee0-417f-9643-1e561d43ea17">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a5a9b8ab-f334-4191-a93d-5a0194888f49">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6de9235f-5534-4bd3-bd48-9d6f9ea017a8">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_db4b78ad-08b2-4ed2-b83f-e4d705c06574">Verbal Source Identifier Code Sequence (Trial)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e8c93af9-dfcd-4828-9f1b-03fc23bf7e85">(0040,A358)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7fe7b379-dd5b-415c-a588-ec1845eb0eb6">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9a3ba783-9649-42b8-88b3-89ec51191cfa">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a47745e5-2a78-460a-b69b-9eb6609587be">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed1489f2-7cd5-4fbb-8284-4d6cca2b07a4">Verification DateTime</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dd611ea4-ab99-4789-ab3d-e18751c5b6e2">(0040,A030)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9d052c05-5197-489c-baa3-af37d8335807">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4450006e-edef-4d14-99dd-d0d6eed6650e">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_42aa32a7-1def-4c9e-bb52-52d156d2a490">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9088b611-2e9c-4481-b0e6-2cd0bcece534">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d68c4f5f-febd-49df-9b85-a859a5ba2a1c">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_206f1f2e-a72c-4653-aceb-2afac51c219b">Verifying Observer Identification Code Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2c97b090-56d8-4483-8a9f-d70f7f8c18b5">(0040,A088)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a819a9bf-e9a7-4d99-a1f2-ed408ff8f6b8">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8b387f56-6348-4d98-abc6-63b9401056dd">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf2a8db3-acb5-4431-9e7f-83af01af7193">Z</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a4dbbf4f-0734-4b21-a839-846edefc703e">Verifying Observer Name</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b94a64cf-0774-4a6f-b5b5-5b07af798ddb">(0040,A075)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bea82859-e68f-40d2-81ce-5b84cf7590af">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_be4dbcd2-598a-4887-adf9-9a1acbe04fdf">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3f7d9563-3f85-4bd7-927a-9c18b96fe3c6">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec289702-2b0b-4ccc-ad83-6b72672bfc4a">Verifying Observer Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1a109fd2-e916-4c71-96b0-6f92e3f46c7a">(0040,A073)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_46247928-7354-4a59-8fd4-92cd047c4de3">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_109d7b27-b7bc-4e96-b3bd-068ca08e56e5">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cc321968-3ecc-44dc-96c0-a55a8ab92d44">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_faaa2dbd-2ef8-433b-bc2f-905aef933f23">Verifying Organization</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e3ab3b2a-331e-4666-88f5-610c8284ff8d">(0040,A027)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7e14e3f-494f-41ec-8bb6-99dd5f86cec7">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b34e42ee-1bf7-441e-9b88-38169de30aad">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc9e58b5-aa38-448b-94e5-ad77446c3b80">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17b1f136-b99d-4d82-b767-1ae64bcc05b5">Visit Comments</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d79686e8-8fd5-46b1-b546-d2a872a691f6">(0038,4000)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e5d34979-296c-4494-8b53-4a18c8de653b">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b853450a-9382-4820-a228-5d752bbb8623">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dc757405-8e5a-4dd9-9db0-18014d88fc81">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9deeb716-dd8a-4f1f-901f-8b67c32a16e1">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_88231f09-a27c-4bae-871a-c25b4e6c8796">Waveform Annotation Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d5ec3be7-918d-4cf9-acbe-722956f2c8bb">(0040,B020)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f56e7af7-c2e0-4cec-830a-d3637755f75a">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f4206f78-9aed-45b5-afe8-125f5c4b10ac">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_97b98398-7219-441a-ba58-87b5e58535cb">X/D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3efed97a-416d-4b1c-8aa2-c17d8523f5a5">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_89a86f2c-a0a7-4614-9bd7-6cdd5d7cd298">​Waveform Filter Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9bb41a84-d7d8-4a2b-b01f-d4c2f9d0088a">(003A,0329)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c6ecbef1-ea9e-46f7-9a0c-bf84193453ec">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_08b0ed2c-00d9-4189-b44b-4b3784a427dd">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_134adb64-6748-4f1f-8b9b-c0fba723a400">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d5ab278-47e4-4d62-894b-b1b8b5534180">C</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a189bc4d-940a-4035-9f6a-14cda7d8321e">X-Ray Detector ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_31233bfd-6596-4775-a2a6-8850be08a2dc">(0018,9371)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_52adab15-6976-4d65-8511-98cb6b419d06">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_98b82fa5-807c-4c7b-9b4a-83a33f4a7a4b">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ab2b4ba1-20cc-43f2-8eae-99e1da6883c1">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_05409fd2-09d0-4229-81d9-bb181b235d8e">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cedf035a-b3bd-4b8a-b96f-35a2c30548fd">X-Ray Detector Label</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3275f691-4d5b-4dc7-ad3b-a3c51e2d16a3">(0018,9373)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7ed492e8-dcc5-4678-ad11-eed3284774d5">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6bc09a4b-b4b9-43e3-8a70-a5187c15c662">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0dc91233-51e7-45e4-b95b-9dc77286ef86">X</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7860b116-2053-4838-bce2-ff34e1c4907a">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e14b01e-10db-4fd5-9b3a-dcb0553efbb4">X-Ray Source ID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c774e946-2a17-42ce-a1ec-fd0aa7d91de1">(0018,9367)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b78f2763-715b-4308-a781-6d037b636e7d">N</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_44e81e80-625d-4d25-9b9a-549dd1b5cbc3">Y</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ddb2c9f5-dc18-4227-8757-d1a3351e26a7">D</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8a81c351-940b-423e-9f8d-99173481323e">K</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="center" colspan="1" rowspan="1"/>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="E.1.2" status="3" xml:id="sect_E.1.2">
                <title>Re-identifier</title>
                <para xml:id="para_f3d4df41-a62d-4a82-bed6-67c5fdeacc52">An Application may claim conformance to the Basic Application Level Confidentiality Profile as a re-identifier if it is capable of removing the protection from a protected SOP instance given that the recipient keys required for the decryption of one or more of the Encrypted Content (0400,0520) Attributes within the Encrypted Attributes Sequence (0400,0500) of the SOP instance are available. Removal of protection in this context is defined as the following process:</para>
                <orderedlist numeration="arabic">
                    <listitem>
                        <para xml:id="para_5b59ff63-97b3-463c-b620-baaf9c1d98c8">The application shall decrypt, using its recipient key, one instance of the Encrypted Content (0400,0520) Attribute within the Encrypted Attributes Sequence (0400,0500) and decode the resulting block of bytes into a DICOM Data Set using the Transfer Syntax specified in the Encrypted Content Transfer Syntax UID (0400,0510). Re-identifiers claiming conformance to this Profile shall be capable of decrypting the Encrypted Content using either AES or Triple-DES in all possible key lengths specified in this Profile.</para>
                        <note>
                            <para xml:id="para_dae74f48-7a1d-4cd6-84ef-c2bca6d4fc99">If the application is able to decode more than one instance of the Encrypted Content (0400,0520) Attribute within the Encrypted Attributes Sequence (0400,0500), it is at the discretion of the application to choose any one of them.</para>
                        </note>
                    </listitem>
                    <listitem>
                        <para xml:id="para_f6c7c02e-f2ab-455f-a868-449791d534b6">The application shall move all Attributes contained in the single item of the Modified Attributes Sequence (0400,0550) of the decoded Data Set into the top level Data Set, replacing "dummy value" Attributes that may be present in the top level Data Set.</para>
                        <note>
                            <orderedlist numeration="arabic">
                                <listitem>
                                    <para xml:id="para_e4ad6c35-5dde-45a8-b095-44f925b0f1c2">Re-identification does not imply a complete reconstruction of the original SOP Instance, since it is not required that all Attributes being protected be part of the Encrypted Attributes Data Set. If the original UIDs are part of the Encrypted Attributes Data Set, they might be usable to gain access to the original, unprotected SOP Instance.</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_3a2643cb-6f3b-4ff3-bf89-f220ce220c2e">The presence of an encrypted Data Set that cannot be decrypted indicates that some or all of the Attribute Values in the message may not be real (they are dummies). Therefore, the recipient must not assume that any value in the message is diagnostically relevant.</para>
                                </listitem>
                            </orderedlist>
                        </note>
                    </listitem>
                    <listitem>
                        <para xml:id="para_f9cea275-9cd9-4112-bd77-630521aaecf7">The Attribute Patient Identity Removed (0012,0062) shall be replaced or added to the Data Set with a value of NO and De-identification Method (0012,0063) and De-identification Method Code Sequence (0012,0064) shall be removed.</para>
                    </listitem>
                </orderedlist>
            </section>
            <section label="E.1.3" status="3" xml:id="sect_E.1.3">
                <title>Conformance Requirements</title>
                <para xml:id="para_6d2a4608-8e1e-4783-9841-ff86b8e54bf1">The Conformance Statement of an application that claims conformance to the Basic Application Level Confidentiality Profile shall describe:</para>
                <itemizedlist>
                    <listitem>
                        <para xml:id="para_624e806e-320d-4b00-ab5b-4908bc3b251f">which Attributes are removed during protection;</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_acd32af8-138d-43df-ba06-a84a38fc0122">which Attributes are replaced by dummy values and how the dummy values are generated;</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_abbef94a-1f47-4835-bb4e-29bccdbf159a">which Attributes are included in Encrypted Attributes Data Sets for later re-identification, and any pertinent details about how keys are selected for performing the encryption;</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_2c67d701-c522-4ae2-9019-0c9c21055363">the scope across which the application is able to ensure referential integrity of replacement values for references such as SOP Instance UID, Frame of Reference UID, etc. if multiple SOP instances are protected (e.g., across multiple Studies, consistent replacement if the same Study processed more than once, etc.);</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_471c6f6e-b82e-4ab7-8d39-5c31721e43f3">which Attributes and Attribute Values are inserted during protection of a SOP instance;</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_2f6ff891-f374-4665-9d88-a4828f2e8c3e">which Transfer Syntaxes are supported for encoding/decoding of the Encrypted Attributes Data Set;</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_392911b8-bd2c-4706-a5bb-50dccc6e57ef">which Options are supported;</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_5faf03ea-02e3-4518-bb0e-faba6a49d5d6">any additional restrictions (e. g. key sizes for public keys).</para>
                    </listitem>
                </itemizedlist>
            </section>
        </section>
        <section label="E.2" status="2" xml:id="sect_E.2">
            <title>Basic Application Level Confidentiality Profile</title>
            <para xml:id="para_9adc9f81-5ea9-4294-b89a-e21ab5b583c1">This Profile is intended for use in clinical trials, and other scenarios in which de-identification may be required, such as creation of teaching files, other types of publication, as well as submission of images and associated information to registries, such as oncology or radiation dose registries.</para>
            <para xml:id="para_621bb5d0-b15f-44fa-9fea-76b75b97716e">This Basic Application Level Confidentiality Profile defines an extremely conservative approach that removes all information related to:</para>
            <itemizedlist>
                <listitem>
                    <para xml:id="para_3604f462-d860-46cb-983f-60314b61eb6d">the identity and demographic characteristics of the patient</para>
                </listitem>
                <listitem>
                    <para xml:id="para_6386d1c6-ff29-4c73-83b0-cebb1d367729">the identity of any responsible parties or family members</para>
                </listitem>
                <listitem>
                    <para xml:id="para_a3f98334-c054-4548-b5a8-d1dbbaeb4043">the identity of any personnel involved in the procedure</para>
                </listitem>
                <listitem>
                    <para xml:id="para_f100eb5f-e9d3-4aae-8e3a-a19db98409b5">the identity of the organizations involved in ordering or performing the procedure</para>
                </listitem>
                <listitem>
                    <para xml:id="para_b634c460-df2e-4ab8-bb3a-2fe076924878">additional information that could be used to match instances if given access to the originals, such as UIDs, dates and times</para>
                </listitem>
                <listitem>
                    <para xml:id="para_84795253-74de-4f1b-b775-951dd136477a">Private Attributes</para>
                </listitem>
            </itemizedlist>
            <para xml:id="para_d56684fd-bc38-4f3c-9877-0c4b20b148da">when that information is present in the non-Pixel Data Attributes, including graphics or overlays, as described in <xref linkend="table_E.1-1" xrefstyle="select: label"/>.</para>
            <note>
                <para xml:id="para_7fd7003f-c014-4715-98c0-37665851f193">Unless the Clean Pixel Data Option or the Clean Recognizable Visual Features Option is specified, this Profile does not address information in the pixels.</para>
            </note>
            <para xml:id="para_5279f5b8-f623-45dc-85f9-a64d7842b064">The Attribute Longitudinal Temporal Information Modified (0028,0303) shall be added to the Data Set with a Value of "REMOVED" if none of the Retain Longitudinal Temporal Information Options is applied.</para>
        </section>
        <section label="E.3" status="2" xml:id="sect_E.3">
            <title>Basic Application Level Confidentiality Options</title>
            <para xml:id="para_54f1923e-319e-4dc7-a2c6-03b9eeae9085">Various Options are defined to be applicable to the Basic Application Level Confidentiality Profile. Some of these Options require removal of additional information, and some of these Options require retention of information that would otherwise be removed.</para>
            <para xml:id="para_31e04a88-0281-4e8d-b68f-d4569f529a22">The following Options are defined that require removal of additional information:</para>
            <itemizedlist>
                <listitem>
                    <para xml:id="para_70734f6e-18c4-4dde-89a0-39e8ba21c2be">Clean Pixel Data Option</para>
                </listitem>
                <listitem>
                    <para xml:id="para_b0870319-f6bb-4768-b83d-85dd1fd8c76d">Clean Recognizable Visual Features Option</para>
                </listitem>
                <listitem>
                    <para xml:id="para_b2e700d9-e51f-4bcb-9c89-2a154a88b810">Clean Graphics Option</para>
                </listitem>
            </itemizedlist>
            <para xml:id="para_b5e7b7b6-fb99-4201-a74b-9e0cf0acb6a9">The following options are defined that require processing of information that would otherwise be removed but that is needed for specific uses:</para>
            <itemizedlist>
                <listitem>
                    <para xml:id="para_f142ae05-3b96-4a03-95b1-deee279b2c50">Clean Structured Content Option</para>
                </listitem>
                <listitem>
                    <para xml:id="para_016380f3-4324-46eb-825e-4e11e1dc1d6e">Clean Descriptors Option</para>
                </listitem>
            </itemizedlist>
            <para xml:id="para_1f84fb8b-37fa-4e00-bc12-81adad03bd8e">The following Options are defined that require retention of information that would otherwise be removed but that is needed for specific uses:</para>
            <itemizedlist>
                <listitem>
                    <para xml:id="para_db0e82fb-5dea-4364-90c7-01f803528585">Retain Longitudinal Temporal Information with Full Dates Option</para>
                </listitem>
                <listitem>
                    <para xml:id="para_e18f5841-373d-4392-865f-1afeabdb9374">Retain Longitudinal Temporal Information with Modified Dates Option</para>
                </listitem>
                <listitem>
                    <para xml:id="para_fa7665b7-3b0d-443e-9aea-5ee5a05eaf9c">Retain Patient Characteristics Option</para>
                </listitem>
                <listitem>
                    <para xml:id="para_3888366f-98d3-4187-8949-727a73ff7127">Retain Device Identity Option</para>
                </listitem>
                <listitem>
                    <para xml:id="para_142897c1-3a82-4edb-8952-bfdbf457190d">Retain Institution Identity Option</para>
                </listitem>
                <listitem>
                    <para xml:id="para_c33124ca-9bca-4742-9e6b-54c48907c48c">Retain UIDs Option</para>
                </listitem>
                <listitem>
                    <para xml:id="para_ebd54700-c7dd-41a9-8ce3-d32547c2c1a1">Retain Safe Private Option</para>
                </listitem>
            </itemizedlist>
            <section label="E.3.1" status="3" xml:id="sect_E.3.1">
                <title>Clean Pixel Data Option</title>

                <para xml:id="para_10d107c2-b55c-4b9f-8817-f317d1e756c4">When this Option is specified in addition to the Basic Application Level Confidentiality Profile, any information burned in to the Pixel Data (7FE0,0010) corresponding to the Attribute information specified to be removed by the Profile and any other Options specified shall also be removed, as described in <xref linkend="table_E.1-1" xrefstyle="select: label"/>.</para>
                <para xml:id="para_16d35cd2-20d3-4904-90d2-cc821294c139">This may require intervention of or approval by a human operator.</para>
                <para xml:id="para_caede39a-46e2-4eec-9a38-1a37dbd70926">The Attribute Burned In Annotation (0028,0301) shall be added to the Data Set with a Value of "NO".</para>
                <note>
                    <orderedlist numeration="arabic">
                        <listitem>
                            <para xml:id="para_5b29f65c-4bef-4926-a5ca-6e8a1a20cce7">This capability is called out as a specific Option, since it may be extremely burdensome in practice to implement and is unnecessary for the vast majority of modalities that do not burn in such annotation in the first place. For example, CT images do not normally contain such burned in annotation, whereas Ultrasound images routinely do.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_6a681c3a-485c-4458-9396-1b2ba559abdc">Though image processing and optical character recognition techniques can be used to detect the presence of and location of burned in text, and matching against known identifying information can be applied, deciding whether or not that text is identifying information or some other type of information may be non-trivial. Compliance with this Option requires that identifying information is removed, regardless of how that is achieved. It is not required that information specified to be retained in the non-pixel data by other Options (e.g., physical characteristics, dates or descriptors) also be retained burned-in to the pixel data. Thus the most conservative approach of removing any and all burned in text would be compliant. This may involve sacrificing additional potentially useful information such as localizer posting and manual graphic annotations.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_af0d1f32-4aa0-479c-9f5b-5abbae62f335">The Stored Pixel Values are to be changed (blacked out); it is not sufficient to superimpose an overlay or graphic annotation or shutter to obscure the Stored Pixel Data Values, since those may not be ignored by the receiving system.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_61b469cd-8e6c-4ff5-a528-61688d80670a">This Option is intended to apply to the Pixel Data (7FE0,0010) Attribute that occurs in the top level Data Set of an Image Storage SOP Instance. The other standard use of Pixel Data (7FE0,0010) is within Icon Image Sequence (0088,0200), which is already described in <xref linkend="table_E.1-1" xrefstyle="select: label"/> and the accompanying note as requiring removal. This Option does not require the ability to manually or automatically process the Stoered Pixel Data Values of Pixel Data (7FE0,0010) occurring in any other location than the top level Data Set, but it does not prohibit it. Pixel Data (7FE0,0010) occurring within private Attributes will be removed because such Attributes will not be known to be safe.</para>
                        </listitem>
                    </orderedlist>
                </note>
            </section>
            <section label="E.3.2" status="3" xml:id="sect_E.3.2">
                <title>Clean Recognizable Visual Features Option</title>

                <para xml:id="para_e022456d-4042-4795-88e5-80e9fc6aa308">When this Option is specified in addition to the Basic Application Level Confidentiality Profile, if there is sufficient visual information within the Pixel Data of a set of instances to allow an individual to be recognized from the instances themselves or a reconstruction of a set of instances, then sufficient removal or distortion of the Pixel Data shall be applied to prevent recognition.</para>
                <para xml:id="para_d4b49dac-f3e3-4127-85ac-eb5eda28a7aa">This may require intervention of or approval by a human operator.</para>
                <para xml:id="para_94fec0c3-65fa-465b-a269-59d262066345">The Attribute Recognizable Visual Features (0028,0302) shall be added to the Data Set with a Value of "NO".</para>
                <note>
                    <orderedlist numeration="arabic">
                        <listitem>
                            <para xml:id="para_6ab43f79-e6da-41ad-ba50-f81ddd02d592">This capability is called out as a specific Option, since it may be extremely burdensome in practice to implement and is unnecessary for the vast majority of anatomic sites and modalities.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_e294e25f-f7a7-487b-89f4-fd76020fa1e3">In the case of full-face photographs, the risk of visual identification is obvious, and numerous techniques are well established for de-identification, such as applying black rectangles over the eyes, etc.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_0effdc07-d613-421d-91ff-f54d3568b462">In the case of high-resolution cross-sectional imaging of the entire head and neck, it has been suggested that a 3D volume or surface rendering of the pixel data may be sufficient to allow identification (or matching against a constrained subset of individuals) under some circumstances.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_f10f06fc-c5ea-4e59-b4dc-18ff46759801">Application of this Option may render the pixel data unusable for the purpose for which it has been collected, and hence its use may require a compromise between de-identification and utility based on obtaining appropriate ethical approval and informed consent. Consider for example, the case of dental images.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_1fad8295-527a-48a5-9471-c1f895326217">Since the Referenced Patient Photo Sequence is removed as part of the Basic Profile, support of the Clean Recognizable Visual Features Option does not add requirements for that Attribute.</para>
                        </listitem>
                    </orderedlist>
                </note>
            </section>
            <section label="E.3.3" status="3" xml:id="sect_E.3.3">
                <title>Clean Graphics Option</title>

                <para xml:id="para_5b5f4d1d-5e4e-4aea-9435-246aeb7389bf">Instances of various Standard and Standard Extended SOP Classes, including Images, Presentation States and other Composite SOP Instances, may contain identification information encoded as graphics, text annotations or overlays. This does not include information contained in Structured Report SOP Classes.</para>
                <para xml:id="para_628bbc9f-6ba4-4316-bfcd-fdc7bc2d3076">When this Option is specified in addition to the Basic Application Level Confidentiality Profile, any information encoded in graphics, text annotations or overlays corresponding to the Attribute information specified to be removed by the Profile and any other Options specified shall also be removed, as described in <xref linkend="table_E.1-1" xrefstyle="select: label"/>.</para>
                <para xml:id="para_503874e4-0dbf-49d2-b74d-4fb26d630d97">This may require intervention of a human operator.</para>
                <note>
                    <orderedlist numeration="arabic">
                        <listitem>
                            <para xml:id="para_09034aea-2f35-4d77-9b96-562b7587edf5">This capability is called out as a specific Option, since it may be more practical to simply remove all such graphics, text annotations or overlays (as required by the Profile without this Option).</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_26150ea2-5502-4c4f-8949-b9377b987281">As with burned-in pixel data annotation, deciding whether or not text is identifying information or some other type of information may be non-trivial. It is not required that information specified to be retained in the non-pixel data by other Options (e.g., physical characteristics, dates or descriptors) also be retained in graphics, text annotations or overlays.</para>
                        </listitem>
                    </orderedlist>
                </note>
            </section>
            <section label="E.3.4" status="3" xml:id="sect_E.3.4">
                <title>Clean Structured Content Option</title>

                <para xml:id="para_1294be4c-ecba-497b-aeac-e3f632c483fa">Instances of Structured Report SOP Classes may contain identifiable information in a Content Sequence (0040,A730) encoded in Content Items. Instances of other SOP Classes may contain structured content encoded in a similar manner in the Acquisition Context Sequence (0040,0555) or Specimen Preparation Sequence (0040,0610).</para>
                <para xml:id="para_004bdf87-7f40-48e2-b5f4-eab3e21d7103">When this Option is specified in addition to the Basic Application Level Confidentiality Profile, any information encoded in SR Content Items or Acquisition Context or Specimen Preparation Sequence Items corresponding to the Attribute information specified to be removed by the Profile and any other Options specified shall also be removed.</para>
                <note>
                    <orderedlist numeration="arabic">
                        <listitem>
                            <para xml:id="para_5fa77649-98ef-45cf-963a-b082652e733e">For example, the "observer" responsible for a diagnostic imaging report may be explicitly identified in Observation Content related Content Items in an SR.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_e45876e9-8a4f-4bef-8737-a9aae6b58698">A de-identifier that does not implement this Option creates significant risk when attempting to de-identity a Structured Report unless it is only used to de-identify instances that are known to have no identifying information in the Content Sequence.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_bb6ff3a4-7cfe-4321-b911-b9f6fc795f49">As this Standard and external Coding Schemes are maintained, the codes specified as Concept Name Codes may change. The previous codes are considered Retired but implementations may continue to send them and de-identifiers will be expected to be able to continue to recognize and de-identify Content Items with the Retired codes, including the Code Value and Coding Scheme Designator, even if the current Standard does not publish them.</para>
                            <para xml:id="para_7623ab23-c94b-423f-aa40-49c221e6df44">A notable example is the change throughout the Standard from using "SNOMED-RT style" Code Values with a Coding Scheme Designator of "SRT", "SNM3" or "99SDM", to the use of SNOMED CT numeric Code Values with a Coding Scheme Designator of "SCT". A mapping of retired to new SNOMED codes is found in <olink targetdoc="PS3.16" targetptr="chapter_O" xrefstyle="template:Annex %n “%t” in PS3.16"/>.</para>
                        </listitem>
                    </orderedlist>
                </note>
                <table frame="box" label="E.3.4-1" rules="all" xml:id="table_E.3.4-1">
                <caption>Application Level Confidentiality Profile Clean Structured Content Option Content Item Concept Name Codes</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0155a911-9c50-44ee-86e0-efbbce57bf69">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b6a25b69-8e6b-4151-be5a-13e2864ba735">
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7fc04f1d-213d-418c-8559-5384f6b1f82a">
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_40e0cdcf-9533-4c5f-9a78-de5b4ce788a1">
                                <emphasis role="bold">Value Type</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ba4ecfe4-8c09-41fd-8cfc-e9e196d1dc98">
                                <emphasis role="bold">Retd. (from <olink targetdoc="PS3.16" targetptr="PS3.16" xrefstyle="select: labelnumber"/>)</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bb36b29f-130d-494d-8989-aab1264852dc">
                                <emphasis role="bold">In Std. Tpl. (from <olink targetdoc="PS3.16" targetptr="PS3.16" xrefstyle="select: labelnumber"/>)</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_12e242f4-ff96-4754-bff8-fa29a1694fc4">
                                <emphasis role="bold">Basic Prof.</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eb730268-a1e2-494f-aa67-7d8f732a9c84">
                                <emphasis role="bold">Rtn. UIDs Opt.</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_21a7132a-0e6f-4253-8243-006002c06cf0">
                                <emphasis role="bold">Rtn. Dev. Id. Opt.</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2dca8e62-86d9-4b5f-911a-cb6ffefb690a">
                                <emphasis role="bold">Rtn. Inst. Id. Opt.</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_18ff8609-e5b8-484a-8926-6e933c2b844d">
                                <emphasis role="bold">Rtn. Pat. Chars. Opt.</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7503078d-0009-4b35-a8e9-3463a8be2317">
                                <emphasis role="bold">Rtn. Long. Full Dates Opt.</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a3dadd42-5b99-4b6f-a23a-15204aa04340">
                                <emphasis role="bold">Rtn. Long. Modif. Dates Opt.</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0f4a744a-ecba-4b27-a382-8509f2907a7a">
                                <emphasis role="bold">Clean Desc. Opt.</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_32fea948-e359-4121-b2e1-66d18dba1df7">Accession Number</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ce50492f-8cb8-46b2-83a7-a155406203ed">121022</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ad91bde3-64b7-49fc-8278-125721d9682e">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e1c07a0e-ae13-427f-8871-16f9d261723e">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_23e2265b-13f2-4537-8f3b-a6554ae95296">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d0b1cf8b-ec8a-44f0-8f65-d4474b8acc78">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4fbeb37c-618a-40ef-adb5-7efdfd886904">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_92430732-610e-4488-b31c-6727b2b20e3e">Acquired Image</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_adaa3b14-623d-422f-8065-7b577fe01dd8">113795</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d7a8e3df-6b4f-4e0a-9c6b-7d6b5a73bcd9">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_50b46458-5eb4-4bfe-b0a3-26822c60138d">IMAGE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_397d547d-21d6-486b-b194-950c0c400e94">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ef9958ae-0aaa-46b5-a6f4-5926dca61f84">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_57afe150-1858-432b-bd95-ec466d0281fd">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dd46d286-a139-4f67-99f4-b4bcaa32c2e7">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f9e5ade9-013b-4f3a-a0de-63eaeee6be9c">Acquisition Date</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_10fe6180-886a-4f79-8d55-e5ea84200968">126201</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_341ed9a1-3961-4a4c-b513-d81421efae75">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7685cb99-5e2f-4d40-b074-62de9906d6e0">DATE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6461d036-5dd5-45f6-9070-464a3a2d220f">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_62104751-2a3a-40f4-a1ba-c58743b74e06">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3ece219f-0569-4aa4-8d56-168779fe09d7">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_39b4c0bb-2c9f-49b5-a704-d305e77027cc">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_42fed641-ff78-4565-9876-c3ad6bb4d2d1">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_67b8473f-bf94-42d5-9dfe-892aad95954c">Acquisition DateTime</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_18cbce12-0827-4b8f-b4ce-bd4d7b50ff56">130884</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c873ee26-2c1e-442f-8f57-cd6d7e0dab4e">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ba76d6c1-123a-416a-92ac-6ba32a4edbc8">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d105b50f-85f8-4c1c-858b-53bdcc2493a6">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7280661a-9a97-47cb-b1fd-7074b0ce0aac">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_80daa8c0-9ca0-4c86-a472-50398c50d931">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_af7223bf-4338-40c5-9ac3-cb82c7319e84">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7506fa13-fa5b-4fe8-a1d1-859f1fe48df2">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7acd19ba-dec5-4257-a59d-48537bd2e261">Acquisition Protocol</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_04785df2-b977-4436-85b6-4fc2703f5020">125203</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9bc49c91-af4e-4c97-a329-0313ebed957e">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6032fa2c-79be-400b-9b18-6113c242ff66">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dadcc88e-0db0-4ab7-8faa-188deeb69daf">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5413f08f-7d15-4848-8bf3-3a406d09255a">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6cbc5bc0-b001-485a-8ada-5f5d1ab3aec4">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_762bc46f-43cd-4c2b-af8f-e38af95ab0f5">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6ba6f1e9-f62b-450d-88ca-290c9dda1c80">Acquisition Time</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_06283107-4ee5-4b8d-8772-340110b92c42">126202</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7fb3523b-f1c3-41ac-a942-4714904372d8">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4507efbb-7614-48a5-9e23-dd2664378736">TIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6c9d5a8c-ac48-41dc-939a-c677de829f0b">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_766656dc-436d-442e-95c5-19457209f566">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_150d86bc-9ce9-45c6-aa5a-e534ba6c2a1a">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c6776ffd-aa3d-4ec5-a034-30a523564e76">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5190f90f-b750-4bf4-852f-eba82f7a8bb4">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_38f047f1-b2e7-4642-999f-6b65bad59b7a">Activity Session</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_66deaec2-9cb3-4c77-8217-78391bfcbbec">C67447</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d3ba5d65-9e47-4278-813c-2bb5b90c985f">NCIt</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e4eca7e1-6034-4ea9-a39b-5db6573015e4">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1d2ffed7-5303-474e-a3e9-5bc41cc12a9a">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f48299b0-5acb-4116-b408-74105d4d66af">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bc6e5356-bf5f-44e4-b503-e5bc57dc9cd8">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9d8ca7a7-46ad-4e41-9a94-795c4569637f">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0bfc88de-0e81-443b-9162-d1f2011260a0">Administration of radiopharmaceutical</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2993f2ce-bfc7-477a-adca-4f598f8258dd">440252007</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_15c970f3-b106-4449-9cac-063ed8a98766">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_acb346c7-c8aa-48f2-bacb-adab1ef2cf0f">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_713a6ea6-fb62-490d-9ecb-665f9633ee7d">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6c604996-e24b-48b6-a649-4d4f74142551">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_623aeda6-237c-4185-89eb-a9ad96d25784">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ef4ac572-c940-4a00-a3d3-82acff4483bc">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d02190d6-c87a-4a1d-a8f9-4901ec7f8d6e">Admission DateTime</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b242a519-de75-43a5-8c4c-662307d39703">15</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_51596147-b7eb-4e16-8a57-d53e3f3695ea">NCDR [2.0b]</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d517ab8f-1f1f-4008-8162-f2ff1bf00ced">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_db36ea9f-37fd-4c67-adcc-c9638f6eb206">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_56fa4ba6-e5d3-4ac0-abc3-5d04bd1570f7">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f6053acc-f3e4-4c2e-9a5d-c3a03ad3024c">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8c86038e-6a8f-48f9-ab6d-82b993a4f82e">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_734e0135-a92b-4d79-8a73-2b217277e0df">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e413ea61-d058-4838-b11c-b726a452a013">Anatomic Identifier</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_734edf52-b337-4586-93c7-4acded9a8c2e">112050</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7ac82eaf-a4b6-4066-a2f4-7949e3e269ca">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0ae0ba78-2006-4ef4-a084-2e066fbae1f6">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9825ad19-c128-4b69-8bca-24c149111a0e">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ea4da2d7-1180-429d-a9a2-f0356696a161">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9fd995c4-6f33-488a-a8e1-01f0d6d820fd">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e383b727-bcde-4fa5-adea-35f9479514cb">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_287cda61-babd-464f-9826-1e0bd022e155">Anesthesia Finish Time</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b847611d-2617-4078-9d6a-7a46642e667a">398164008</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8da74455-4918-4f7d-86c0-9aff0873c8ee">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bee25739-248a-4c58-9387-705dc960b77e">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fa8f8860-ed97-4f52-b893-f93aa32af48d">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_10c93317-3ca0-456a-8e22-ba8c84c7c5d8">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_87414090-0202-47a9-8a32-1d2ec15f4e9b">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1f6f5c3d-5d73-42b3-8f95-9a18d93ae583">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_633e6fa0-047c-4a75-881d-7a8bfcf1bee4">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f28d7511-e3d1-4cea-ae84-8aaca4d62aab">Anesthesia Start Time</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7a060ca8-9d8d-4b00-b62d-9e1b0038f224">398325003</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_964821f0-046b-4f05-a5a9-f16b5244a1e6">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c551e36c-76a5-4c25-b657-a5f59aa94247">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4470f269-3287-4804-a0d5-84fe153005e7">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6edb3669-6470-43c6-a113-358993b459a9">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_11e77312-ecae-41e9-9384-d28e37bd34d9">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_20861588-4dba-4836-988e-449971e76754">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_efdc5247-9154-4301-8acd-3999f36cec4b">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9e6cf130-f153-4b7b-ac5f-2187daf3d010">Best illustration of finding</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fdd5c8bc-e917-4be0-b2b6-ccfbdff7444c">121080</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_683438b0-5b20-4323-acc4-140f57494b84">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d8c7402d-cbfd-4f1f-a36b-44a9de356667">IMAGE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c1dae382-cf8b-4737-98ec-6a4ea8ce66c8">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0bd8f77f-3261-436b-8bce-c1cbcb2f7e49">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_25343831-e92f-4df1-a2a9-da364f666c61">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_22f711b3-6192-4205-b315-7ea5ac1b3c84">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9a63ba40-ff4a-4697-9d19-e030551de8f3">Best illustration of finding</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c45d2d51-a0b7-45bd-acbc-cd5ff7476a1a">121080</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1facd363-853b-49cf-b677-25d41d9a806b">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b9ce469a-b0ee-4a76-a9c0-c2e2af2f0cc8">WAVEFORM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1db7d2c0-3fae-417f-9462-b58c8a40a1e4">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b5822b51-4b6f-40b5-aa1c-552abdb0ff53">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9b84a8e4-0b18-4f7b-b70e-3fe31191b8c9">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2e06c7a9-4f31-4d42-8cc4-ba14297edc23">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_fdec7c35-8777-4acb-acca-d3c76bae966c">Calibration DateTime</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_195cde08-9fcb-4e30-b5d7-8e8ed1948b10">113723</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0816f458-b7cc-4e1c-b714-8cc947ad7fc5">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f423230f-ca6b-4231-b4c2-45c9fc5f09e8">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a63b7068-82fe-4b25-8da0-d8e75cbff108">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_46157380-08b0-453f-a6c8-4b7ee69016d8">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_211afaf5-6a6a-48ec-a05c-32c0f961e39a">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4fc8ea79-996d-419e-85d0-754def45ed9d">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5ddda98a-d46b-42e5-8523-d47cb3aed710">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_18a4436a-0686-44b1-bd18-607e4d80205b">Calibration Protocol</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_df350ca4-f610-46e2-88ec-bfec2223ece7">113720</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_85639500-ac20-4530-bcdc-fc18a5181c2f">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6640c74b-a1f2-4068-93b2-d15355d3d725">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dc739091-9166-4910-83bf-9e5ff56e75c6">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_12b909f2-e17d-4a1f-b1b2-bc90306d331f">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f1b04edf-ea79-47d6-8f7d-c5f2de8d4e27">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2776d847-173b-40e9-9a4c-affba04a7b42">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_74ae5b2b-aee5-4c77-be26-3a58b0c7730f">Calibration Responsible Party</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3c8e8e21-8a05-42af-82a0-85e3d63c9a16">113724</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_670652b0-b23f-4d91-b6a5-ab15be4d6f25">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_baf2f9b6-ddf6-4840-ac86-d8bfb94494ce">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_62772b6e-e2dc-4cd3-8600-b75b859fee49">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0df7ae31-bc3e-44d9-aa27-8563a4545875">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9dccee1e-03fb-492a-8946-34616fa9f3d9">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9c4e2feb-df2a-4125-b7ca-736bfee905ae">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4fed494c-72f6-4187-a0a0-3461d112ed21">Catheterization Operator</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_235f52d3-7862-4a85-816d-bc0837fdc2ca">76</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b54fa92a-3f2f-4a02-81e1-2ab1b2f31489">NCDR [2.0b]</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_35237e4d-70c3-4ed2-b9b5-d09d17b26b1e">PNAME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_56154cfa-e6ef-4635-b809-cfbba5a9db2c">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a619a116-a39c-46dd-afdf-a0b874768977">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7885fabd-5a64-493e-9b42-3c57a22874a7">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e6095da9-3e1a-4a71-aaec-bf857d507dee">Cath Lab Procedure Log</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1e0ec0c1-db77-4052-b2de-81ced2379cdb">121120</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2c340200-b0c1-44fb-9fd3-30130b7b2a19">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b1764eca-90dd-47d2-ab23-5176acc03636">COMPOSITE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3e5f12dc-2259-4174-a6cb-32d3a4c32981">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_aa08cf69-5c7a-4d6f-83af-07b6e655afb1">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_49f9da69-4a6d-4cea-82aa-9809eb73bdab">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4786f5d3-1b26-4a07-8ad0-7f74a089ea54">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bf2e8eae-03c9-4d69-8038-3c15c8324f8b">Clinical Report</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ad5d3bbc-0c78-455b-93f1-98e553e40045">371524004</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_aec58211-11b4-4cf2-98d5-16aba1ba82a6">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3e76cc23-1d08-4a20-a218-f16ecc95e663">COMPOSITE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c32bbbf4-dd33-4ecb-8612-526e569464ee">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d4b48227-4cc3-4c35-81e5-55342d875b84">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bd440081-4756-41b0-a298-3ca8a91d6a5a">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a661df58-978f-4de0-9cf3-5d7443c54b6a">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7efee9a2-5860-4f3b-887d-db229a34a267">Clinical Report</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b219a62b-1af5-4c8c-a8a3-fea579d0f9da">371524004</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_69ec0dfd-fb99-4297-8f9b-cacf33428a40">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3be78f4c-c523-4ac6-8638-4a05e7f50078">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a4d2fc75-f6b7-45d1-b990-201cafe78e03">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ba4c7f68-9b85-4567-9230-086c391c76f3">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3127b051-4850-4774-968b-4bb3664f9b13">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7b6c580f-3671-4fcf-9788-638591c18042">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7a66600e-aa38-42ce-81d5-8503ed87db6c">Comment</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6a6fd119-e506-47fe-98cb-fc3afddb8bb5">121106</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_48550edb-bf86-4c2f-8225-bd0a75cf9ade">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_15c25a4f-fa06-4967-869f-7c096b8c2d3f">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2e7673d1-a035-4cc0-8ea3-3299d91464ab">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b773cc76-adab-4323-a864-1117cd0e09c9">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_aebfbc2d-27af-42df-83e9-29c9fbade534">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3b4f11da-3965-4fb4-a9c1-3b0b0c78d2ab">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a719f519-2930-4d0b-88f2-f4fbdffc46b2">Complication of Procedure</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d1c7a988-3b25-4d35-93ad-350197d6f49c">116224001</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1dd1c948-2fcd-4b94-b674-3c04ba6eb6f2">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cadc257d-6311-46f0-83bd-02e1fe4d0f08">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3909a14c-26f2-4689-ae98-3fab6ff729d3">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b0f1f29b-cb30-44b9-af00-715e3173541a">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_75f9e1e5-f4a3-4c60-8fad-30c4ce954f65">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4d6ef8bb-cf8d-4546-85b6-9548c826764d">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_81262e7f-c4ba-4dcb-a5a2-5be2ca9320b3">Component ID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_83e1364d-1369-48b9-80ec-dcaed87155f6">112347</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a514543a-528e-40f7-bf8a-906d49330901">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5f82b709-7dc8-403a-b9c1-9511dd6048bf">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d49bca2d-1f25-4e86-bb50-a62b4e72d045">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_14ef7afc-a702-4cdf-aa5e-286f7b73279c">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b6c48745-ef0c-433b-b03e-c9114dd2dbff">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bcc14845-2925-42c5-9d78-c15af876dc5c">Conclusion</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e72c0c92-505c-40df-b45b-39c5fbbbb207">121077</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b9b8690d-e845-426b-a1f0-897c3b7a9635">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1dd4958a-4c28-44cf-b9dc-5423f1864a58">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2c100414-f171-4cbf-a3b2-07405531b234">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_acbe7955-fbe5-4ba6-88f3-3264c9f97864">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ec912515-3db6-4ec9-9620-18cd3a0b08c1">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ece4cec0-7fdd-48e7-aa22-77687de81bc2">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_24fc593f-fc22-4385-a8fb-2ae4c58e4e14">Content Date</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9230e84b-e355-45c9-8622-71fbce605766">111018</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6807b7d8-da99-41c3-9102-728dc44835c0">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_35bd31a5-e881-4e93-b8f9-f43b5784ab2a">DATE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e8925a22-83b5-40c9-b00c-eec50ff30a9c">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0d5ed06a-cc0f-4ec3-9874-0473b3903c65">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e2edbaf2-b3dc-4222-bd37-db06710e26be">X/D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_46e5478a-d6a3-4301-9661-d2bb4a5361d6">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4030e9ce-fc36-4def-bd17-88bc387976fd">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_54853c58-8985-4fb9-823e-43a1bb621081">Content Time</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_837956bb-41d0-4ad9-8e2f-3e5defe4c1a1">111019</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0ef61d02-9972-4aed-820e-f26eefaebd94">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_47578cf5-8476-4365-a2f2-68156a76bcec">TIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5d9b7f06-8233-4c47-add2-e9fda04f06ce">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_30039baf-f57b-4398-b7e3-a2de4ab5842d">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cf9607bd-a219-48d7-91fc-fd13bc31483a">X/D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d984b4f1-4072-450b-8867-05e61b57e21f">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_59343211-2424-430c-ba63-975c41a11cca">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_92ca7d4c-c4ab-48a4-b902-d7a8fe417fde">Current procedure evidence</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6cd48419-842d-40a1-9b43-96b0bf4475d0">122073</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_03a8b14c-5b0e-4435-b5b5-ae321b079f45">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e765873a-9e9f-401c-894b-d0cfbddb08e6">COMPOSITE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9aa86f9c-63cc-4644-93ec-89d7d1e8bf16">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cff6a3d6-0579-4c9c-ada0-6b4d62c5b612">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6930fdca-4a6b-4427-8df6-b60736bc367f">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d8f23f28-b3d2-4057-b111-8a5dba121959">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_453c7ba4-a6aa-41c5-926b-b3c98a0a8ddf">Date of last menstrual period</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_37dca884-18fa-4b8e-b201-4e17ee29eff8">11955-2</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8fb7478b-7f86-4a01-9e81-6a5a487a9c0d">LN</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cbb78bf7-f9d8-4126-9f8e-b7aa1888cf5d">DATE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_995c992d-ff3c-4574-acb8-e38173527c5f">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f441532d-4af1-4920-be8d-16f192495329">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5c72bff2-1e17-468c-bf9e-29e64282ee27">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c23ff34c-d0e7-4905-ad1b-ce8916e5c5ec">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_58f3390b-0b2b-4344-9ccf-8d3c564ab0bd">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f09ed67a-a55c-4d4f-ba6c-4947d2831682">DateTime Concern Noted</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_26a4d794-08c9-4a34-bbd6-cfdb3b5fd6dc">121431</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9333cd4d-86d7-409f-8f89-3b8698e8a83a">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b6a67e48-f763-4d51-87cc-30b67007a24c">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3424464d-d0f1-4e86-8a19-a5823fd1aa11">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_032450a4-a2a8-4974-afbf-e1d268a2d5ee">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_57e7c235-6bca-4e1c-adbf-42966e605e29">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5478fc54-2be8-481d-9207-ac4a6412fb71">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_50d3aa2d-20ba-4020-9fea-af538c9be53a">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2c678f5f-a347-449f-8c77-d4cdd7cb77fb">DateTime Concern Resolved</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2e2ce98d-0122-4f13-9feb-fa8cb36c487d">121432</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fa7fe556-6e59-45da-a846-0f0cba63f153">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_32d8adec-6e7d-49f3-8ba8-52d1d67654a7">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f744163f-5197-4dcf-9afa-f3ca8302d23f">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_677348f8-e2c7-4f97-b8ca-ce0094a1af73">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_04ea0d7e-979d-4dbb-8ed8-a29a0db0d024">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7df695f7-1411-443a-bd04-d4b8578fa6ce">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_73f62e10-7ff7-4b2b-833a-c37d858d51ef">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0dc2ae44-290d-4c2e-9f69-0b0fa13861ca">DateTime Ended</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_58fe73eb-24c1-4ba2-a399-08d4f6ccf2be">111527</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b1fca4cf-3048-44a0-b642-1e06e66e152c">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_349a5454-3a0d-4f2d-b056-063d98b9731e">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_aa670b3e-7f99-4b4a-ad6c-bed8aa0296a4">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b4566489-1e7d-460a-9a32-12bce399bcf8">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1a8b1851-c050-4139-9776-46989ad76aca">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c6a715bd-924a-4061-9f16-90666d66ec4a">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a1074382-c302-4feb-a073-3f233c4693db">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ebfcf84c-f2d0-422f-a46e-74275f0a9c3d">DateTime of Death</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cf2343cb-4300-4b34-b430-9ea660c87f0d">122165</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_95182310-d787-4de9-8be5-bf046004f949">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9aa82845-6564-4205-95c6-a1f69045fef5">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8dd39e3d-eaf4-4ed2-b589-d59e4dc65e47">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0a80113f-fd78-4f04-b0d6-d67578e18db9">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3df2d0e6-10ac-42c2-894d-c3d197893679">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_36da249f-59a2-45fe-82f1-68074052b218">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_93c03063-a17c-428f-a753-ea756e021e7c">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_75e8200b-9c0c-4f7d-bc26-a97e22e93fca">DateTime of Intervention</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7a67d46b-5bb3-4a14-909e-6bc5aaf06e1e">122105</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d59b81af-cfc6-471b-aa2b-3975dac94206">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e7a97935-c9c1-442b-9b77-c462f3d38488">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2023dccd-2643-45d3-8c19-a6d8e349c9c9">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ee3e6b95-da6b-4a63-9cb5-8be8d5e6975f">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_244e74de-f9cb-42d8-a12a-9132275f9256">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4edc131e-fe97-4933-9f88-8a87b56832bd">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_06de28c4-679c-44b3-a371-1510f6e227fb">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c3846a4d-22c6-4a67-954f-7445e57a35a4">DateTime of last evaluation</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7a48d654-dabe-4eba-bfec-5719ed28f2a1">111536</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_03987640-c1e1-4123-abab-bc6ff4b66a24">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8d30870e-ca99-43b5-9a67-405d1512cfdd">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_77e689ae-ce99-4877-95d8-3f83e86f23cc">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dd19b269-3088-45fd-8519-5422af472660">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_84d3a07e-a904-4483-812b-c8587d573d6c">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1e231602-ceb1-4e77-97e0-8c534a69a005">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6c1855ab-1f18-4bb8-abcb-99ca4b788575">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_56a52a50-d2f8-4e26-a026-b7718997df98">DateTime of processing</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c2d2fb76-66b7-46f8-ad9c-000178a8ceba">111702</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2d71d097-f87b-43fc-9427-57a196cc3dc0">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_54d15639-3a69-4490-992c-10910674a847">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dec6cbb7-caf1-473b-8132-2152be9ddcdc">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8740f0c6-cc1a-4a88-bfc4-aba00572dbd4">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0a77c36e-aae0-4669-81f8-d879685670b1">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e85d1d0a-7561-476b-a1d0-7203b4ae5ba0">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e4599ee5-984c-4911-a950-74d389d28713">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c912c67e-483e-4272-91c5-7f7bf88361b6">DateTime of Recording of Log Entry</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_463ad653-9835-43e5-8d00-5806779a6076">121125</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_856b54ce-31e5-4213-8e44-f767a48ab463">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4d2ee1ce-ccba-4a28-b10f-e8d5ac448161">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b643d896-51c6-4b2c-a35a-ebbf76d785fe">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1095b2b7-c8e0-4444-990b-479cce0ba7a4">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b55e56ac-4303-4e9d-8d06-fc2df75d9201">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_069dd620-492e-4493-9bac-36e578b03b2f">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_63ffb225-6e8b-42bd-bb2e-537f2557661e">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e8824ba7-6b0b-448f-8b75-9f2882bbf385">DateTime problem observed</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_377a16d9-5071-4ce3-a286-81d3ab8b62e3">111535</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_41970340-e8f6-40c8-a7d3-b441d6ddc8d1">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a844bbf6-0917-4ffb-adb3-08e55b3f5997">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_aa998b94-803b-428f-92e7-eb729911167f">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8cf3d054-c87d-4636-8a11-0912d4c9f5e0">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_54fdd3e8-0b1d-47ed-9007-459e5a4d6f63">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dbc305b8-45ba-4291-932c-ce49ddfc4e41">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c55f6f0d-9cb1-4141-8ff8-57f282f2adbe">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_19f1c64c-8eab-4f79-b304-6bafbaaacd58">DateTime Problem Resolved</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e9e1ec96-7cd4-4350-8824-8cf455825866">121433</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9c725b51-4569-4dee-9653-d749c58cb77f">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0a013e9c-6bcc-4780-8fb8-bffddb2a3efd">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b00dfa6e-b2ac-486a-9e67-8b64b31b8297">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a3dd69c1-0738-4bed-8b27-625354040fc7">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1c7fa3ed-3102-4590-b238-7b193e68cd0a">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f3ac8780-f5c1-4160-ab75-0fbf31b818d9">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3d519835-b85e-42ae-a7e2-88eeea9e77b1">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_702efad4-1c7f-4989-bf28-c16075eb10cf">DateTime Started</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9fc32b7e-97d7-4bc6-9c43-f428942dbe5d">111526</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_af1a4d65-abf1-4433-8278-fca8962e3b1e">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_39c4452f-1837-41c3-80cb-80458ef1c1a7">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_50e8b204-8f51-4f28-b403-f3e7eb188b8d">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b5e24214-79b6-4f42-aa19-ac5bb1ba0588">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_88c8147d-cb76-4c8a-a6da-14ac8146be56">X/D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a281e0e0-07ea-48b3-a295-d9618009c826">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ba44787b-6856-4c25-afac-79bc48d39e2c">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5702cf20-e1d3-4d8b-98a5-db560e238a62">Degree of Freedom ID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cef0d97f-3fb1-4853-aab4-4344c1169953">112363</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_24be2be5-6be1-48ea-b2e5-60a63148723e">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_151f83e2-812f-4939-a7f6-e629577287d1">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_15c3ae90-9a55-42b6-9721-8714d51a63f8">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fc703815-a884-43ea-86ea-0e3f25c7f290">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_334d0805-d548-4f43-8c9a-5bbe9a1e6442">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0c6755d5-344e-4a57-bc94-eaf922fe1751">Derived Fiducial</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eebd92d7-a200-4a34-98df-4390c8a98a2f">112357</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9d602a04-01db-4d0e-9e6a-e883d1c2992e">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ecd981d2-5d7b-4583-bd8c-23ed02ad9bdb">UIDREF</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7e63dfdc-b685-4e56-94f8-d7639709e546">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8aec2a3f-f2c1-464f-90e3-6ccbeeecb018">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_584142f5-de5d-4400-951c-c86cac000bac">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d3ee7a1b-61ed-4e28-b88d-b6be19ea1e09">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e7aaf66f-12b6-4b30-a7dd-7adb6e188b74">Derived Planning Data</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3803f184-2e4b-4b87-849e-5c11b9233de3">112373</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ac1f8ccb-534e-4393-9382-09b79cf43df7">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_444f661b-4561-4c4e-b40c-3be8b925720d">COMPOSITE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_db28aee3-51d1-4a30-b59f-fd7187517e52">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ff73c806-aadf-4c73-8215-41c93d84d965">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0a84d3fc-f91d-4e13-8bc4-70c8952c26c0">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4cb7f748-637f-4dc0-8a05-cf1585daf2c8">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_faeb3355-c606-42d8-bc79-eb36363f3f4f">Derived Planning Images</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c5950721-a182-401f-bd25-4353e589745a">112372</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c35f4ee0-af67-4a7b-b010-e6ab3a3b7e22">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_252d3134-b66f-4a74-9eeb-ead7f0bb7cd6">COMPOSITE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9c1c811a-f168-488f-bd18-3f0b2d057aea">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9f88fdc4-9e7f-4e6d-909e-2941a01359e4">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_57a7efcc-6093-4a22-a4a3-81769b228f67">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_12f8ed76-1191-4877-8ab5-cf0ca7e041ed">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_96e131b1-b908-4afb-aedc-39e3a13181fe">Description of Change</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_353affc5-b5a1-4fae-83a5-592308d9e3b2">111021</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2eb5c857-1176-4147-bb67-f9c7be854b16">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a9e542df-6c2e-4bb6-8061-0e22a4151b8a">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a7cf28b1-6c27-42ca-8ae4-884cef36031e">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2a66d5dd-d69e-43e9-ae62-719de089522c">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_596d5ada-319e-4475-82f2-da60ca51c514">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_77456fbb-de77-4e60-858c-462e15909ecb">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7b67af0b-70b0-40d4-ae05-69e3868ed233">Description of Material</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4c50c91f-ed9f-4f81-954c-9e8f09b22aaa">121145</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ec9029d3-0eec-4358-8f54-29a2bf398e96">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_54489575-05bc-4ec9-bd36-6f6255173d5d">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_20dad410-9b1b-4215-b165-ddc334eb6327">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_22b64f12-5706-41b3-928e-759f42db6427">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8940154b-f51b-48d0-afae-0c4d710cda52">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_42c111ee-4b90-4934-91f4-5257e448c208">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7e9feb20-9e9b-4b35-80e1-ac502133dd1c">Device Description</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0db6fe33-0256-48ba-8aee-1364a86e134e">120999</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_70718ee9-ce96-4a31-8dc2-f4f6de7c11be">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_413da185-fce4-4e0b-8775-8b9dabe420bf">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_048c28b9-28e6-4ab7-bbac-20196fa437ce">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_08a7b6c4-3905-40e0-a4ab-7276b47ef56f">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_89ced040-64aa-4eea-9725-c8f37622f4f4">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_44611b7b-0cab-466e-8369-462a2251091e">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4439395b-9e3d-4aa7-93ef-eb2905438ebc">Device Name</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e5e6b0b2-9241-465e-b5ea-9213f9cf8f43">113877</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3e366b0a-0e02-437c-8a5d-a222d49ca53f">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0518ccf0-c903-4643-9ee7-78ba5246953a">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_11cf85a0-cba2-41ef-8267-8139df17ff09">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b80eaa49-e1c9-47f1-a663-e8087cab464a">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b301ae09-ced2-4a91-a5a6-cf882589077b">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_012f59c9-2808-4a72-8e24-027763f74239">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_da333c1c-aef9-43b9-81dd-234ba28f4e7e">Device Observer Name</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_027b4b6a-ae5c-4705-9d13-ea7fe06d9991">121013</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8a4f992b-70bb-487d-a6da-6b279b5602fb">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cd379ee6-6ca4-4ef6-a767-d350396e5998">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_62e7de00-a212-4b77-bf7c-255b74cbbe62">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_de654d88-077a-407a-87b5-5bb75fa9984e">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_593a2d04-3d04-48e0-947d-162eb284afd4">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_afa1e310-222c-4e1e-a19e-9f2413c47c13">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2d3b1eb7-4959-4ed8-b6ec-ac382caa9857">Device Observer Physical Location During Observation</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_93afdecd-a4d2-4769-8ac5-0997ea318115">121017</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_44712041-094b-4f5c-adf8-3da699faeaaf">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8c0af9f1-a65d-4986-9695-7b1a66928218">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_38445ded-837c-40e1-a7b2-629d34fcafb5">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9f4805f1-ac79-4b4d-9795-682e6fe18e9a">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_54ba6248-1776-43b6-b10c-e52e6074a273">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9ff56d06-2d6f-46e9-b469-0f93954eb389">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a1a08a1f-e0b7-4d22-85dc-42cd590dabe9">Device Observer Serial Number</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_591ed50f-9c74-4255-aff9-44f30cc44922">121016</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_98e05a7e-fb83-4a26-b15c-719ebe4648fd">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_39039738-49d0-4e19-9f38-a3e7b6eb4a60">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_36f9ea9a-cfdc-4bed-9a33-9fdd616250d4">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1bb2c48a-c00d-404e-b459-ddacade7dc29">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9b520a6f-43a2-40f5-8e03-86be9d685f83">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eb39383e-357f-4cdc-b4f8-28986e9ba953">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9310a59a-77f1-4ca6-b82c-2d3704cd82ad">Device Observer UID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_545426ff-03d9-4d7d-9ff1-c7dd8aef7723">121012</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a58b0d99-b314-4cb6-a8ab-ba3c8e738f19">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6627013a-be62-4af5-b188-2b42757a6e85">UIDREF</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2c7df948-0ecd-4b0e-9268-219674ec5376">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a151b206-d799-4e3f-80ed-6800cca5c1ad">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3e09e112-01f5-40b9-8f67-4b0dcdbad902">X/D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_46f7a683-ed1d-4611-a19a-f82657924a8c">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6ab2eaee-d506-43f2-948d-9875667d8ed5">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6b31a57b-ae46-4f7e-802a-75095d50c7aa">Device Serial Number</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d717da93-7e42-474c-9497-d395cf2a0344">113880</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_aa3d048c-f759-453f-a46c-1ccd1a9d7b82">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_89092d8d-dfd5-4bbf-9369-12c63a00e5e9">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_12639434-2291-4067-a0c1-4fdebfaeffad">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_82d02441-7b6e-4256-9c7e-3e04498fe4c0">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0e910eac-345d-4e92-8c02-3728e5b5b1d8">X/D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7b0b8772-d276-457a-9b77-61ad95a36191">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ad6d960b-775b-4e49-ab00-db7b252cb238">Device Subject Name</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e100db2e-dee5-4c86-bd34-9b5562c948a2">121193</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d1114b90-bd1b-4946-a3e0-76a5156ed90a">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_57417319-3949-4ef4-87b6-59d84099e3e6">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_78760aaa-9cb8-46c9-86c9-bc923c5fe2e3">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0142f544-2caf-44c3-b8e4-f3962b4499e3">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c2b7f59d-bcc2-4891-93a4-2f13a67bb5be">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a52ce52a-30f2-4034-95f5-87a3babbe8aa">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_63953711-01d3-442d-b99a-d495535e6cdc">Device Subject Physical Location during observation</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3efeb36d-04f4-4802-a3e6-5b9520147dc7">121197</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5e0b5175-e829-4892-b169-4eca1010f4ea">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2930e36e-ef71-4508-91f9-5b0688f707f8">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_326c9e2a-54bc-450f-a950-e1d29f0fac19">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f0ab3f9a-5990-4645-a2a5-8a9757c03165">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f1813b61-a58e-49e6-9db6-afe97941fa66">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_020e96fa-b73f-4ca1-a8de-ee62f4079d32">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_04f59aae-795e-42b4-8330-e3baec3abe2b">Device Subject Serial Number</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8cb4b2ef-77e4-466a-b914-608b48da54b4">121196</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6c3b4021-6d19-4f53-8c07-fa962b8d8bf2">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8657e5db-f9e4-4f45-babc-0235a3585ebb">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8050db17-ab5d-43ba-81fd-0edf013a8085">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0d6b3638-23ea-45d3-990c-ddfb7bf750ae">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_532a616e-b8ef-4c8d-b2d6-be4eb5a239c6">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9e63beac-a442-4c39-81a3-69b6e88d1ca6">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1a7b51c0-1946-4ead-abee-ac3088faa1ac">Device Subject UID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e93331b0-3034-46a6-a8fe-6119f0c50e1e">121198</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9edf7ae1-84e7-4401-8209-e6de7edbff7e">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_876a053b-7b0e-436d-99c6-126c6c99f282">UIDREF</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_982b70a2-92bc-43e7-a19b-7ff079621363">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a7324ce0-5760-4b94-9a34-9d0fc54ffd80">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_741736ee-b309-41d0-afdd-c215f3f91ff4">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f58823b4-5826-47a2-95f3-c4a65075a843">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_32819613-73f5-4131-97ad-4b6cd6390127">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_19508a25-22ba-4f17-a06a-02fbc480e598">Discharge DateTime</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_14becb0d-704f-4540-a2a8-67fc009d3ccc">122163</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bf3e52be-695e-4418-b756-f06099801c04">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cea0d35f-8b04-45d0-a45d-e13a9115b67d">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3edb631a-802e-44e4-9485-cf9b907e9ffd">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_96f9fd91-19d9-42a7-a779-ece56bf07a08">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4d769d42-b964-458f-ac10-cebea473f24e">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_55bd6dfe-55f4-4335-ac8c-fb339f251ecd">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4d9e76e2-dc79-4cdb-a778-7e1a47b9c254">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e2d71299-a46b-4b64-9163-e6b5a8d2303e">Dose Image</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_840515b4-716e-4ee3-a713-3e1cf0dfd3c0">121342</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eb99c10e-0b83-4b05-aa74-898363d80e61">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3905ac2e-b3d4-4bb1-a905-71a24849ad0c">IMAGE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6f31d868-c8b8-44f6-a7f5-f492d1ca3b2d">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d2c4e421-5ce9-467a-8909-35cdeaac57ab">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_017c6a84-da8c-4173-8550-81d569391cb9">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f34989ea-d692-4c34-97b2-a14b463d9aa1">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_048be4a7-87f2-4433-bfa1-f5abf6c7a168">Drug administered</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5a6887cb-f32f-42c2-9479-7e380fd14a0b">122083</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f4ba223b-db32-47a0-9bea-bbc88460161d">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_14ab0cfa-0838-457e-a2af-9b8717bdedcf">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dceb8507-509c-4c3a-b97d-b78edc66e828">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b0e48f88-8c17-4ad2-90d9-1d83ebd84913">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_73ff4d70-7b76-4aea-b85e-3cff9b089dbb">X/D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_06f44e06-4417-4af7-8baa-bc773e8fdf61">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2d522fec-e475-4c8f-bce5-209925a6135b">Drug end</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_19ee5a4c-bb9b-49e4-a02e-7af6b13b2c5f">122082</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f1402ddb-f6bf-46b0-8795-02c49e8479c4">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6621108a-9dd1-422f-a669-a03ac1e54267">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fef45dbc-745d-4cd9-a55f-121e90a6de4e">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d3b14d80-f338-4cc2-be4c-a880635c62a4">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_42b63580-f2eb-4a46-8c9c-f16cf4ede560">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4255f869-e567-473f-922a-cc103bc8c841">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_70b12031-7c04-4987-aa1f-72a4b6996fbd">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5bb524ca-1399-4bbc-9f4e-ff694249949b">Drug start</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_609f94f6-e2e8-49eb-b944-be03aa1ccef4">122081</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c335a3ed-fce3-47b5-8a9e-a24c9e32315b">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_630132b4-002c-4cf1-8d27-4e7a81e16ae7">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_106319a2-bbb0-4f8d-88e0-2b0c3ffeabad">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3d9545ac-dfcd-40f1-8fac-8374b7550fbd">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d6ea7dd2-82cd-4c82-94db-8103f5637261">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_60805365-4c4e-4086-9a90-f11a123f6fcf">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_83e807de-b98d-4020-8106-9819d475f311">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e8d6894f-7858-4bb0-8787-f84831704880">ECG Finding</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4c9959a4-a789-4ebb-a504-7c0043b2fdbe">271921002</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3793cd72-9e8b-499b-a02a-bf8606c7be3d">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7d9ee961-827f-4097-8f0b-eb5bd08ff95b">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c2d1207b-1e16-45ed-a28f-af0474abf0e5">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f7d5587d-6b5c-4166-b519-9fb230626cea">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e197e215-914c-4063-885a-a9074b59fa25">X/D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_38dcc4d0-5a15-4d5b-a244-01b28645fd69">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ddcbf7da-10e0-4b63-ae6f-c244bdf149c2">EDD</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_565266d4-5708-40fc-83b3-93fc509bcd66">11778-8</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c24a1d70-bb7a-40ff-a99e-b45c5bf3a37b">LN</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_29003e9b-b952-427e-859d-b6867993f51d">DATE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4faf879d-c2ed-4956-9b23-b5f62373b051">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_11d7b522-cac0-4f67-acf7-97ca9729b275">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b8bbd2a1-ab3a-4b6c-aba9-e5c81ec2e6d3">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b0994934-2cf8-4145-a25e-4c013d681f99">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_93015279-1409-4ce1-a9db-ae104df0f952">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ea7f438c-2e7f-4c0e-9cc6-1d2812cec701">End of X-Ray Irradiation</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5cbb3cfb-4992-458a-b06c-c49acb8f8b5f">113810</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_be96f382-8417-4c24-a954-aa1a82388e9f">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7e5a2d73-a482-4be6-800f-ffe1e33aa49a">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d575364a-d39f-4f99-b45b-a674aa3d8886">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_228389f5-f573-48fe-a5c1-88e80c961163">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3aaa63f8-105e-4671-bb19-c9e9ca3acebc">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1f61521e-c44f-41c0-abf0-b321926209f6">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bf9ae7dd-1399-4dac-9bfa-1690e3716249">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9fb9f9c9-8886-4a9b-ba00-ae899a1113c3">Equipment Identification</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_81b58f43-ac13-4aaa-9527-45f65fe36cd2">121122</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3066779f-6218-402a-bf74-dbb94de6c9da">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9cba34ed-f78d-48d2-a99c-b9dfd40e4530">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_094c4683-1dce-47a7-a84e-18e48a599a45">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2ab00ea5-9eff-429a-b8d8-cd75c28d50a2">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_41d8e812-0006-4b8d-8048-483a7a2ff2e8">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eb31db85-9186-4042-9cc4-6b1242d9c2fb">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_95cbaa80-4817-4e40-8313-76739f97fd35">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_81a646ee-efe2-4c7a-b36c-00543ce90f5b">Event UID Used</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_932c1158-74dc-4b59-82cf-0226dc436401">128429</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_78c2521f-04f8-438c-84f1-06f4afc27dea">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0e37cd74-1574-4f26-9ca4-2151ebeb8252">UIDREF</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_93ae4072-cd2b-484f-a205-2e9a9f9922d9">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f2ed29b2-09c4-4f36-b84f-c490c325bd85">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2f5b370c-6ddf-4d61-8c42-9635ff432103">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3f6bfa26-205f-4613-a2d0-4ad29cc77870">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bc151dd2-3c1a-4c12-bb2f-9a27a5e89cfd">Experience</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_35dcd269-76e2-440f-b372-717a970dd553">C54627</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fa14665b-e4d0-41ca-b886-4137ff74c96b">NCIt</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f3e60155-0881-4219-9bb8-46f7ebd29eb6">NUM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c622ac6b-06e4-4f5e-a282-e7b36c46e17a">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5b40551e-03a4-4f4e-984b-fa7f544f8452">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7b5b3710-c16a-492e-a0b6-a5d822b90445">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3bd56928-c940-447f-934a-7e140b2692df">Fellow</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_efd8b32d-16da-4684-8c7d-13aec78dbc89">121088</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_98ba4afa-8251-41a6-9b48-37a67a0f8091">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_05d313db-af32-43bb-95fa-6bb27682edd5">PNAME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_89f0cbd8-ffe6-450a-873a-c0367819181e">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3b06517b-c2db-472f-a599-a0c36d75e64c">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e3cc66a1-59c6-42cd-aee4-1965e6cd8869">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_cf2feaff-1bf3-4f4a-8eba-bc51a4315b76">Fetus ID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d3ede015-c51f-4235-ac0f-6cf47c9a87af">11951-1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cc43a2dd-b87d-4b00-9aa0-694855c33489">LN</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_20fe7bcd-f0a7-4af6-9959-2a943f6ad3c0">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3b75eb54-1711-4b6d-a24c-148851a409e7">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4e83375d-5afc-4190-9b6e-033cc719e5aa">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7cb3d408-319d-4a85-95b9-325df9fe30bc">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_66a18a3a-7bca-41c2-ba2a-3db8fe700d2b">Filler Number</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_224e6223-8a4e-4a61-a9f7-a396420cd39d">121021</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_37c7065f-ffb4-4baa-bbde-e9956a47839f">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9c1b7efb-55b0-41cf-afe0-f1f7755d1e8e">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_687d7977-c2e4-4612-bf09-7be94d67a2d2">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8f8e3ffd-df3f-48e7-8c4e-bab519c34702">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0b3ac415-972c-4e56-9095-d8233a2dbfdb">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_885e59f2-3545-47bb-a3e3-b3ece66a4095">Finding</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2b751cb9-07f1-4c60-902e-e457528c8ced">121071</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_43bcdd42-705a-4922-af3b-1e1b5174428d">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9048e782-67ac-45d6-a2df-7e855776780a">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a60ce547-44b0-4668-9872-97c06779f909">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8c603314-e984-4ae9-aea6-279a0b772811">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5e391890-72d1-455a-992a-d857b4196a88">X/D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ed3d7317-bfce-4f49-950f-a7fb9bfdc86d">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9b61b413-e0bf-48a6-96b9-69cde4908150">Finding Site</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2210e461-3b05-4736-be8f-3a2cf3e0674f">363698007</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d7c8ed2b-4c13-43b5-bea8-866d18a6420c">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_18ff0a15-5281-4671-a5ca-4d174f28a811">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_23735eca-455c-4830-85b6-ede8fdb2328a">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_86424d98-fc38-4cdf-8f8d-16c13a7f66ad">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1e4dff88-e9e9-46d6-a4d6-24317cad7ecb">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0aa1844f-3bb1-46bd-832d-7ccd5843cd4b">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e75be36d-fd2e-4506-bdc3-3838a1ea590f">Frame of Reference UID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_11b1c657-449d-4b3c-9221-a72825c44820">112227</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f1f0b9c2-b724-4dd3-aa15-7310bbbbff97">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_45ea5fad-57d7-4226-9756-ce39e21c9d0c">UIDREF</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_67d96b8b-b259-4acb-bf31-753eb867af4c">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d0a19e02-b32b-4a48-a0c2-db16e95948f1">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7496e3c2-d356-4f7d-a458-a0a685f23835">X/D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f2b607ec-abd8-4a65-a88a-b4a68ba94b45">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f2d6874b-6b4e-4649-8a95-09cf8c913a74">Glucose Measurement Date</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cd8b1e6a-a60b-4e56-8435-29d72adc358c">127857</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f6d75b2f-cc27-4ecd-9b69-86cfa7c1649f">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_530b743f-bce6-4f10-a5ae-43f0745ea158">DATE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_09d523cb-acbb-4444-9129-938131d6de84">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d9df1555-f730-4338-9699-52284c5a1bfe">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_98ace649-b7d2-4509-ab29-1deae172a5cd">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0c5a51b3-ec5a-4f85-85d8-0c8bcfa19f3f">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_50718bee-24f8-4b1d-8110-82f98891f623">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e5eb294c-7abe-4e90-b039-c11980809c7c">Glucose Measurement Time</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2d2fa9ac-87e3-4919-b32e-c2487acb97c2">127858</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_af8f92d5-73a0-4126-bf4a-d2ed62e36232">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3d2ad894-16af-4a20-b49b-e3954e8c7dbe">TIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_523c7a4e-bd47-40d8-a6bf-7005073bd897">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d2473e39-5f60-484f-9d62-a919ee4fa2ea">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8e63aa1d-8b81-40fd-9223-61882db84706">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8c80e3a7-34ce-44cb-a28f-0bf45da354a9">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a8f93ca5-6c11-4c3a-9792-cae223e07b26">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_05d684d6-2f0a-41ac-b286-0eada7a1c0b3">History</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b9a28250-62ac-4c9e-b7ea-4c1824e20321">11329-0</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ec0baeaa-0fa4-4894-98f7-bfc9f52c2844">LN</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_aa81b39a-9a86-402d-9e7e-bf66e68463a2">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8d3da74c-68fa-400c-b334-63f3d6daba00">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f6f2f626-164f-4f4f-b4f0-c085b5112e4a">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f3c4dff1-0d20-416e-985b-3b8ee8f911db">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_431358fd-46ef-45c0-881b-bf0001f2cbb3">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2b30f7b5-c6ad-4166-8a2b-9f871d596cb8">Identification of the Attenuator</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1e00b74f-434f-4b9e-982f-fa9a0d6165b8">130527</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a9c61e8f-e4f9-49ab-8614-6a8cbcf9111b">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ca7df23b-ee09-46fa-8a2a-adef27c2757b">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5f9f695f-1001-44cc-b88c-53eb6728f3ed">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_12f6ebe1-1a4b-4667-9f65-e34dd6f97a64">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a974a2e7-ea0f-4c37-911f-a5547487863d">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_07bd7dc2-0da5-4574-8224-ea27e078bc72">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_db98b588-f175-40d0-a325-22bbf6ec6614">Identification of the X-Ray Source</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_652015a9-7e83-46a7-997f-b82de86639d5">113832</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_20d9b53a-4b49-470c-8acd-8576c318514b">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d746e412-1903-4c69-9f51-7d2a4196fc81">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_682762ff-4ec9-411b-ab2a-ae07522bce8b">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cc4a8fb4-530c-4811-b4f3-0e3b7f1ea71b">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2a67b9f6-d76b-4ce0-bef6-60947392d24e">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_436ffd6e-ba66-4354-be1e-67457653d8ef">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_49689e12-adc0-461e-a999-4bebece7718d">Identifier</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_377fc880-d4d5-4e9f-8ef1-9c9ad982cd65">125010</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_80e59d06-c4fd-402b-a714-b0c99e7eb3d1">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c40ad0b9-736a-43fd-b044-fc55f8525f1d">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f63f171e-315f-4f63-bb2d-3fac13e14e16">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eb5e7471-7141-45c1-8282-ba7bdba6b142">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f11a9d6b-dd50-41de-ab35-3227e453e878">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c2de1804-41ea-408d-b902-3a7e6f59287b">Identifier within Person Observer's Role</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c5cbbd7a-f8af-4d6a-8856-658e2dd8acba">128775</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_db88ed53-538b-492a-9277-5d61849a1f9e">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2f326232-9f7b-4ee8-b6f2-3245fa8c8074">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d520ad37-6034-440f-aff3-547e6703f19c">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fe1a844b-d0ff-4e82-b742-892c890fbcee">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c52b4ae1-48db-4fa1-a3ec-c62bb813807c">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a20ff827-4522-45ea-9986-fd2497335d53">Identifying Segment</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_14c862bf-56b1-41da-8bf6-f8de747daaac">112229</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_67971e03-e420-40b3-8214-1f11847feca2">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_57560a45-ef9c-4669-8579-2977a2ba6db5">IMAGE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4a6132e1-81a0-4cd3-9bbc-621bc08b8d9f">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f37085eb-731b-494e-a6be-14cd9642e82d">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fcce9736-d058-497f-a9ee-0c51a6405bd0">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_72c5efe9-3cca-4ec8-bd7d-94e81592401f">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_51c7bed6-90a6-4d70-8bf5-1bae27ccbf4f">Illustration of Finding</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_862c1437-9b7a-4bed-95e3-6583918d978a">125201</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c6c6cc2b-86f5-45bf-a92f-9a2ad14f06e9">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7d6b5cc8-af97-4305-80f7-84f238b1fa51">IMAGE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_93d5017e-8323-4a27-ab13-563e589c9c91">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5d4c4272-a549-4df2-88e6-86bcf2f10844">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_31774458-8e2d-489a-bad5-866d210cc021">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8bb286c8-60d8-4565-b7a4-e17aba0d24af">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_888b8854-d6ae-4e17-839b-0ad6739ab6ea">Illustration of ROI</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c2a6e430-dc5c-41a9-ae36-977eaf4a6acf">121200</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_137762b9-0b0e-4def-a111-498c07d4c149">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_68a74905-522b-484b-b912-9b1fff616b4b">IMAGE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5fcd90c1-7b44-4b47-9f1e-546e95b21f1a">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_22397f4c-a466-4e7e-9625-c5b3fefe4202">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5630c8d4-4044-4e98-9f54-c34d68c72d98">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_36b01261-70f6-4e0a-aa54-d3efc86271bf">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9404be4a-ea90-4f67-80cb-bd7e255420a4">Image Acquired</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_918f1c3c-5837-4144-907a-3134621320f2">121138</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fef3bfc8-8c59-470c-9c43-42348ed2eb8c">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7b0f1ce9-b5d9-4e76-a946-8480055d7ce5">IMAGE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bc55ce58-cbb5-4f55-8d62-bcdaea47bc4a">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_856e60ae-a574-462f-b1b6-278263c8305c">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ff1b3b79-fe44-4388-81ae-d71390e2d6b9">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2d51878b-d69e-49ec-897a-af1f39db17a4">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_24f5aa76-e9bb-48ec-a299-430af96cf4df">Imaging Start DateTime</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_047368e1-f1db-40b8-816d-37ca798eadf2">122712</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_59121b3a-db74-4ca5-a3c6-b60380869304">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b80ee9cd-a488-4957-83e8-9cb622e3bfb0">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_20f5a39e-c6b4-4a13-a0f5-d364b7b3f0de">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6b7a3029-342d-477a-8a74-6b6d9aef65be">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5730c210-b8c6-4760-a835-ec0c693b5719">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6b753ddb-27b5-42f6-aa28-d7db30a87e66">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_83da46bb-ba26-4cbb-b64e-42f7f311c764">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_914e6636-d20c-4c0e-a4c9-46da626cd26b">Implant Assembly Template</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c0e7b565-eb24-46bc-901a-404c62d8e509">112366</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2484bd63-02be-411e-a2d6-7d2b81b9219c">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8cd6f6c4-f39c-4c85-a163-541ece6e5c93">COMPOSITE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f8922cff-6582-4ce7-9d1b-591d43d4b81f">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_168d9f70-1f34-456a-9daa-bb1c51176766">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3741f18c-72f4-4e59-b076-2ff89ca2233f">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_646d04ad-9710-4131-bac6-fd95203372b8">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_893ea56c-a155-4cf7-aced-46177071d913">Impression Description</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_395b911e-959d-4faf-aabc-bdbcd06b2c37">111033</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c8d900a5-767d-4c72-8718-f08cb2951fe1">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7ff71348-168a-46e7-8d39-ebeed4f25701">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c959956b-da04-400d-b118-338566a18ac6">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6f11e8c4-7131-49f1-9e1e-e1fbec664f17">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bc9bca2c-99c7-41c9-8d32-581084db23ce">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ef160330-59e6-4c2d-916b-adcff7d7f5ef">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e514630e-ef58-4167-8149-0f85e17e4f9a">Indications for Procedure</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e24d5e99-ec82-46e6-8aad-1d362dc174fb">18785-6</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_422132a0-8f3c-49b0-8077-5b86640503be">LN</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_59383abc-0d04-420e-a11a-57709ba499e3">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2092e175-780e-419c-ab53-c7fd2dce1860">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_04e67d2c-dd4f-4830-b1d4-f61575df5474">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3a6302d9-c81b-48e9-9f88-c680573d9a90">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d6bbcb56-012f-439e-9275-ed8bcb374d51">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_adc5d525-18a3-47fb-b50d-11f4c4372e1f">Intervention attempt identifier</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f3a5eef8-f3ac-4eb7-bd26-e15414c00df6">121154</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6d44d522-5956-4b02-a84a-0263e05d22e3">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ef81e427-13d1-44b3-9e85-e45bcb32adf1">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_55ebdc7c-2dd0-4b96-a669-6d2bbbd5cd3b">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bc013223-4dd4-4bba-9f2b-57b6d6ade357">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f48032e7-80fe-44a5-ba42-2a145548eeef">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0a64eec9-fc73-4374-b658-7eb61f98c338">Irradiation Authorizing</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_92e1a113-3d2e-4c98-836b-9223f257bc8d">113850</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_84f1da5f-1dad-4d6e-afe1-30c09fa63a6e">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_76b11c73-cd4d-42a9-a21c-4f9a578fc909">PNAME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ab9fb296-fb96-4d7d-99b4-d9ef23fb3660">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2828ef29-4c71-4c4b-afcf-aafce865002c">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d513ae18-8732-4fc5-89e4-acb8eb676bde">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9afef9ea-da4f-4715-828f-355ff7f313ca">Irradiation Event Label</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6f6fd16e-d5dd-42ea-86f5-8142a47c2648">113605</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bc18392d-6c1b-4673-b884-2b886d2c40ee">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3e970324-d182-46a0-905e-03cf292dbf65">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c0a3f40e-2dec-4eb5-b8f4-91344cdbdcc3">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d7f515f3-5fd1-4534-9ca7-148def356459">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2037ae67-0855-496f-b598-c285fb3f35a5">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_54bbcbf7-5e90-4da2-a8ce-0791ae7dd30c">Irradiation Event UID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_84924b99-4121-44b9-8876-32778b20aa0c">113769</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_601c1a23-c08f-4909-98a5-309f395fd873">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_82d34d8d-edd1-4c5e-8d8a-a1363449e032">UIDREF</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6d6ac690-d4d4-4f1e-8f6a-cb85ab2d7062">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4c4db040-a623-439f-b57d-0090c9f9020b">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f2fbb940-595a-40c8-a973-2158c5bb796f">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_48ad704d-6ae2-4a20-9d43-c29a129c6667">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6a66df9a-483e-4bcf-a9fb-2dfd25805201">Issuer of Identifier</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e82c59a1-750b-482f-97ae-e3ca87283b4c">110190</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e8b52c84-4b7f-4cbc-baaf-a9fb9bbcd2d5">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d254166a-a7f2-426e-a704-fb690dbb5858">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a6fbdbba-a25b-4acc-a8af-023ef1b79cef">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bc922542-d04b-4612-8966-651e6caaaf3f">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7c714161-a927-40ac-8e6b-e4b5e4b9cd8b">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2024bf6e-4cb7-48a7-bb1f-b84c26876ae4">Issuer of Parent Specimen Identifier</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7e582e7d-171d-4501-8f25-d45df2ced025">111706</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ad45a715-d856-4b34-b0a1-45a4a3511756">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9d9c643b-7602-4325-a171-05b71b54c883">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6a8214b6-96a6-4003-ba2e-4d7aedba0e2c">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3b1816a5-d50e-46fd-a0a0-f1ecaf9bd382">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8ffea2ee-8385-46e4-b60e-608184ccea92">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_39c9ad00-3765-4434-b1cd-a5a2311a3ead">Issuer of Specimen Identifier</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_da651d4a-df02-47ed-aa91-2deb9afd59a0">111724</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_da83c990-5f05-4662-984e-6a0672fee57d">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8327dbe2-5bb0-4768-93d3-e4ec8a713abb">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5c974977-e2cb-430d-9bf0-91c1002851d0">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dfeca0ef-7648-4e10-b15f-56471c14fdee">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_122bf348-6f5b-4ba4-8e45-eb4b0ad854c5">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_523d73fa-f5d4-4b07-8b03-c68e7749c156">Key Object Description</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5b69ab8a-5418-4968-8795-b24089908a03">113012</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_83977edc-a5d4-4b7a-be55-835a9b65c858">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_abf549b8-6001-4dd6-ae9e-dd032054c960">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_06a0786e-031c-4b8e-bf54-07ba7f619312">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_38d1d914-3cde-4beb-8b4d-c970dc138b2c">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b20c6754-10ad-45b2-bdb7-2e1a00805a37">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_47abe25d-a5b4-46e8-b7e3-c82aa6170b01">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5c95d1d0-0329-49a4-bd38-60c020b30bc3">LV Wall Motion Segmental Findings</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d5765c3b-63f9-4adc-9062-1f5ab97d4c49">18118-0</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6e64279f-93cb-4d34-af68-c12b5954eb74">LN</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3eb86739-524f-4f1e-8ff7-8b2b1771c777">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0c3ac272-cf3b-4996-9297-fff49a8f8cb9">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6822e40e-d0b2-45f4-b7c3-bdbf956f645a">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4f77c64f-1449-47e7-8416-fecca7f51252">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c424f8ea-11dd-40fd-a36c-30ccb4b32629">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e35e3826-f7f4-4142-8f32-a0d947dd4334">Manufacturer Implant Template</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f98e6b8c-8ec7-4dda-8d7b-98356818dc76">112371</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_46042e33-afe2-4d61-82fa-acc2933f08fc">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_98b0f0c6-8058-412b-a72f-9f858eb3a274">COMPOSITE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_302fb399-ff74-4a3b-89d2-ae598c42346d">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6f51eaea-14e1-439b-9dff-e7fa0da8b133">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2988e5ed-d4ab-4646-98ad-44609b7d5fce">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f0e7a2cd-2124-4fe0-8a1b-800feaf27e3e">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_04946d5d-688b-4071-a06a-86efd0b709d9">Mating Feature ID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4fa16869-2bd7-4ab0-83a9-d3f18af27669">112352</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_40840c01-f439-499a-873f-377cb646f26f">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_85b80920-b605-4a22-98da-eda665c70bf8">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4b5e64b9-4119-417a-a853-85828fbaecd9">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9e847055-4b1f-4dec-8c96-9af0bc9ce2fb">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_81004bc5-f0be-48c1-b57a-1cd7fa68ca87">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f2f4ac32-4a8f-4f26-b08f-be3e324399a2">Mating Feature Set ID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_522d5f9e-bf1b-4414-a272-2828b34f89c7">112351</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dc72e637-2653-4dff-a2ff-0ec4ca5e32c0">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7a50fe7e-d96f-40a2-8216-6243fa84f828">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6f81fc05-4ce4-497d-bc0c-5d82c62d2588">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bb438d1e-dfdf-4468-80ae-c9f13ff31a31">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_492e4b59-0e04-48aa-b136-321f1a47f986">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_59e1b51d-bcde-4fb8-9773-2f70585d1845">Medication Type</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bd0315dd-2de5-495e-a231-e261f599cd18">111516</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_08e2056e-2828-45ba-89e0-7868d8b6651c">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a2f3cb41-f362-4fcf-a574-53823630b6d9">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_212d87e5-6efc-475a-95ea-db56c738c69e">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2c7ff3ab-0e9b-45ce-b97f-9fe64a5199b7">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_930e7fab-5ff2-40af-bf33-c3e91964ca5d">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8188a77f-b162-440d-bd57-f79dff260dae">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c822af8f-566a-4f0d-9124-73b0b8bc1f8e">Mother of fetus</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_87b8bf61-01d5-4f4e-84af-9400d05cc05b">121036</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_06c53149-1cd3-4873-a348-9edc4b731cba">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_039be775-54da-4d24-9b27-25f953023232">PNAME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_adcd46ee-8c68-4bfe-8386-748ed8231be9">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e1d1b3df-28ad-4fdd-b863-eee7968d4847">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a01c3a67-330e-47cc-a466-c5de4e366626">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_08b2fc9c-e548-4141-82bc-b53c54df8e0d">Organization Name</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b3bf9fee-c032-4730-9b8f-eaacb018ae19">113873</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_407a04e0-19e3-4f9f-8094-d1f65e565b91">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d6d0b202-44b9-4438-a501-13217b51a407">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8960e582-8b55-48af-8510-91f839b537a3">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b5c205c8-1a76-405c-8686-55ca7c3df50c">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f18b29f3-d5d7-47ff-bf78-1d40e501fd97">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b8cbf035-e4bb-4924-bc25-19f81f636529">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_eab41d7d-0b8f-4913-a900-926814430706">Original Source</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_db87c53e-1235-4838-8522-bb5ae18858bd">111040</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5d025c61-76ea-4e55-881f-3bf4367f13ec">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7cb1203d-5851-44aa-9c28-e3aeeeb0ab80">COMPOSITE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4306f2cc-2675-4e64-94fd-ffcd6c2b15b9">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_83f3b5b2-20ff-43a0-b669-c7da4ede32f4">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_40ebda88-916a-44f0-a07a-436cf4d7a656">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9130e4ca-355f-4ab4-96bc-14bef78958f6">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d5887405-bf6d-4fc0-a817-d66fb96b9705">Parent Specimen Identifier</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3f57e3f3-5688-4a5c-9387-716ce493086c">111705</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_640d3a50-f3ad-4cf3-981e-a914410cda66">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6ff4383c-04ed-4086-8499-6e7610662fce">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_168fd4e0-f85f-4650-8419-21c5270a54fb">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_632c39a2-cbf8-47b0-baf4-df74daef3d1f">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_be283ea2-8907-4aa1-9259-da7162b9d829">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d51a92f7-8975-4c1f-9913-5a84a632bbfa">Patient Data Used During Planning</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5ea64a3b-8992-4787-b498-62053e84056d">112361</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_865d9a23-4966-40dc-b3d0-d1491f8d4341">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d21a2b60-cff8-46f4-a92d-315648654338">COMPOSITE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_777869d9-99ef-4058-852b-d62c06c9ec18">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e51ccf33-9ebd-4b53-93bc-57325cbe0879">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a4445c4f-2945-4411-8669-2868993a227f">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_41460cde-302d-4cf9-81eb-f91128bf9f42">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2bf21521-56ed-4b8c-925d-6e5a8a4d850a">Patient Image</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1abf9e74-6de9-4cbe-9f51-06e018166104">112354</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_91de94a5-64eb-473c-bd38-fdd4843a5de5">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_69a7a2e0-2e9d-4642-bf1c-928a81e19d0f">IMAGE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_76f785bc-d409-42f2-9f99-0d966676e14c">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3044206c-9d7c-4400-800f-d39c94b261b2">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_efdb7663-8ae6-4aec-86fe-7c6f03741652">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_36ff9597-ef63-42cb-aa4d-37c428f4284d">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0920d6af-0356-4013-bfd7-bca8739b3cd0">Patient Model</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_097dea1c-0932-41d4-8749-4001910f2eae">113815</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a5f9c44c-73d7-46b5-ac34-e2bd0a815902">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dd036883-e04c-4ed9-8001-2d399752a4f2">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3635d602-ecac-4e44-8bf1-af4c4d1409e2">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6057e0c0-9105-47dc-8038-449c21e268f2">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6758b580-d823-44bb-9f7b-ee207fe6cd6e">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_61ea8c07-fd02-47c2-b0db-9db6c2f7528f">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4cf37cdd-5b96-4aa9-813f-7562a74605ed">Patient Presentation</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9cf4c9b2-9fb4-4038-a511-18f3d0c9185e">121110</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ff35cd5c-a77b-4bf1-900b-1246b3ada28e">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_349cca55-0720-441e-b3ba-204d82c5a5a3">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5b055ee2-38f7-4559-8211-eb4f121711a0">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6299dd08-b6aa-492c-8443-87f1b2ed7c0b">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_10a4a1d1-c79d-4bf7-bbec-298643e6247b">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e61212d7-3d6c-4c41-bf6f-c2943f83a0b7">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_152ea429-7660-4521-962b-99639044fda1">Patient Radiation Dose Model Data</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ffdca7e1-e99b-48bc-98ff-33feb638e912">128425</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ca6b23a2-d4e9-465f-bae5-d6c8a8e2c18a">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b81e17b2-c676-41b7-bce0-6ee523f28160">COMPOSITE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_09e56307-2708-41a9-a295-56be25a7194d">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f96b5a35-66f6-49fc-b741-71b46d58d8f3">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_61e71c2c-a932-4087-80ee-2e405c3c425f">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cbd2908b-7159-443a-b255-460197a66506">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9d8177fc-8f73-4458-93f5-78a366ae9b44">Patient Radiation Dose Model Data</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_92342c4b-25e6-4ee5-813b-027325739d61">128425</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2dda959e-4c65-4aaf-9b3b-3e9a0b73cbc8">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dab14f0c-fdd2-44be-b4f2-6571d7528e9c">IMAGE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9bda6193-7471-4f2f-a1fb-f05b01f121b4">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5ca9193c-472a-417d-bda5-e58c40f712c3">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_18036f31-843b-4093-9880-b807e58bfd8d">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5eb08eef-d20b-4b29-8393-08afeda3dbe5">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3b40c670-1687-4d2c-9a23-47af8f7c210c">Patient Radiation Dose Model Data</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_214c264a-3146-4f79-8040-43ae7f50606f">128425</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ea2ef30d-0029-4f2d-a5fb-7aabaf174a2a">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1735e12a-f021-4a1a-b7b4-58f1dc1363f8">UIDREF</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f29c66bf-77a2-4fde-bbb2-c788d6af2dba">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4f790f12-23ce-478f-8ee6-15be6a9da973">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f0042abc-70c3-42c4-a006-1a1fb745fe26">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a7215326-12ca-45e5-b685-4aaeab498839">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_617fbd5f-5a2a-4ea8-be2a-6b32ccfd8a90">Patient Radiation Dose Model Reference</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_da297e70-f2eb-4787-b35e-d58f50d6d109">128426</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7963eb2b-2fe0-4f61-b4fe-eaf9f056b6f7">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f61e529c-e3c7-49a0-a850-6ab4ed87b143">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_20235e4e-b4bb-473a-b748-6f6d1cb23eaa">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9a7306af-d7d5-47fe-bfd8-fdd8032840aa">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6c228cba-7445-4cd6-b56d-662eae1c2e86">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0fd01c45-e8ae-4185-ac6b-f621d1583c0c">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4493f6e2-8548-427d-afbe-45525bcb3617">Patient State</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_202dce85-cb53-41d4-a54e-ead65496d82a">109054</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_da0a1934-120f-4acf-a8b0-94bdc60609ec">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_399eda09-9979-47b0-82f5-9d60913a23bb">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d9843a7d-3a23-4c88-9e6b-cf364ca482dd">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1487ee62-b727-4097-9b45-329236dd6f8d">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3b4c8f1d-71a8-4bdd-b6da-2bee247aa562">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d5f99f89-5a96-42ab-8325-c1391f291eee">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_aeed3460-503c-426c-80c7-cea365c02ded">Patient Transferred From</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d07dfbd6-d51f-4efc-be41-d0fb512b6ca5">122128</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6b5269f9-5ee4-4523-be6c-dcbe7fd7fde3">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_57f384d2-bea8-4671-851d-a046a961eb4c">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f8923316-75f7-47fe-8cab-51449c8eb2dc">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d231dc4c-108f-4961-a884-6b7c21abcfa1">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_79dd36ff-7e23-4e8e-bc75-969ac106b9fe">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b6bb594c-729d-42d3-8acb-9b3825e539f5">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4c4bce4e-2a04-4cb5-8f2c-4374ce8c0d9c">Performed Procedure Step SOP Instance UID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_761d1b07-b14b-415e-b251-51588e9833bb">121126</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_10075395-f44b-42f6-b4ac-c702d7d9dc53">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7b03ba3e-17df-4133-ba10-443937601012">UIDREF</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_16f7a5b4-197b-4081-883c-1679b3b321f5">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1989996f-dcdd-476a-96d5-4637e41fea1a">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c69d9be7-5b26-4625-903f-2dcdbbedd741">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8ddb2fc1-8e4a-405e-9e9d-bb850ccaa541">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3edf6a97-e916-4d76-91c9-ababd13b27d4">Performing Physician</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_09caeea4-3df8-4f94-84e9-339f13924394">121114</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_af50365e-77e6-4a57-a817-141557f18ebd">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_05fc6819-c9d6-4fd3-a505-17f5837f2e83">PNAME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5ded0175-af15-48ea-85d1-046dc7cc0241">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_841e2e98-9fef-4fd4-a66a-d6a86adb8d5a">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fcd97e46-63a9-4281-a897-2a2385408de8">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f732aaf9-28ef-4065-9d74-0077d35bffd3">Person administering drug/contrast</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1641e3eb-7c9c-4d6e-bce2-ff06bd1454d4">121152</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_366acdb5-583e-4a97-91aa-085a535d94ac">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5a1a38e6-c50e-404e-a270-2e1200a9abd1">PNAME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6a51e9e4-487d-421e-87ba-e73a1e3b4c4f">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_239f287d-010d-47ca-ba42-fbe4b92fd04d">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_af737350-846f-4eb9-8118-8720c4e688e1">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6497a31a-f714-4041-b91c-59c673804352">Person ID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1dd376f2-4a9c-4f65-a602-790217c8c3c6">113871</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_78802d38-83c8-4443-bedc-2cbd64a90db6">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7b57a257-8763-4d9a-b08d-2d20d9a16088">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_854b5a0a-5ae8-4a4a-b882-bfdc8ea23047">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_131551cb-b6fd-4e92-860c-e7e16cff4bdb">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_546dfed4-513c-4605-b445-5daf7532a111">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_77a20eda-7ad3-44f2-a1c3-f67e7241e979">Person ID Issuer</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1bc9824b-96f5-4c3c-ac3b-4cf8a543748f">113872</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_515c5836-ce56-4076-b150-3ffea84dd269">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4d8e2053-395e-4e9e-9467-71695d82f0d9">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8fe3aaa8-5cc0-4c0f-a482-9976a5dbec3b">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_10900f04-7908-4a87-b9ee-79cb761d4ad7">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c67107b3-8680-41e9-96c6-b8e6b31f129c">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1d45b51b-0ea7-4840-aaec-3846d3e704a4">Person Name</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_df7cd693-4277-4d85-967b-d1f057dd87df">113870</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_15b8cac8-57d8-4719-b744-a5095730ed1d">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_24f54f37-5718-44fb-a409-e9b458462b15">PNAME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a05fda0c-e23c-4f99-b4bd-ca337c469769">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_878109db-2c34-4a17-9184-8c40da6ace2e">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ee90cacb-7923-4ccf-8231-c75a4178bbad">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f2d48e34-6554-4f06-bf2f-0cff0c607947">Person Observer's Login Name</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_55b490a7-13cb-46fc-a1b2-d7cc405860d8">128774</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a797bf5f-5319-4932-8bdd-7c121c7999a4">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7a6d7420-c623-4f41-8a58-0d4cc4c56708">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f9c3fa30-1ccf-4b37-bdef-b7499b817366">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_693ca5f4-83a3-4cd7-8f17-0d3bf48418fc">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c83a6e2a-b958-476d-a2a0-25c5154ec741">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c910308d-581b-4936-a4b3-9d51f7843310">Person Observer's Organization Name</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3d617f7e-b9c9-44ef-a8dd-fb1dc819645f">121009</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6f1fcc25-1ebe-46c6-94f0-d1e6b2d149af">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5160ceab-14a2-48f1-b683-0a68e48fdc18">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ef351d68-75a8-4463-ad0d-180cd196b95e">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a2dc60ce-9284-4997-859e-fa2b20cf3f2d">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2ccec340-4160-44c5-a903-7998f851740b">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_aaf7b574-10a2-4629-8566-c4f74bbfc8f9">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7aef2909-d561-4197-8a7f-e5dea7b0e1c2">Person Observer Name</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b01e78cb-ac7f-48fa-81fd-13197f946f4c">121008</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_11ac7cee-8f0e-430f-b909-2815f0356064">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_83f0ff4b-d868-4af4-95b4-8ca51c49e7a4">PNAME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_89d09c96-8f0d-44aa-b429-1d0062aef3f5">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f12a237d-b335-40e5-8a24-e4302bfea1f5">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4e1b9ccd-31e3-4f90-93e6-462794a778e8">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_975144c8-392d-4cf7-a7c5-383947a53bde">Physician Note</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e1dcf2e4-e21d-439f-b290-04dc14adbe2d">121173</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bebcf02a-6dca-4598-a654-a1c363e6e0e0">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6626f6ec-6750-458f-9d2d-70352230e67b">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7df745b0-311f-4793-bc7f-56defc0200ff">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_be92cce2-c679-472f-aa65-4ea2f9c30b17">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_04e6e156-9ea4-48e8-b1e6-5ec9bf46f6e1">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ce6db9c9-c396-441e-a68c-a2d2283d65ea">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1fbbed57-4b4a-4d25-af42-3f107f0681e2">Placer Number</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7828bdd6-33ea-4736-b32b-1c513010f330">121020</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bc13a373-881b-486f-8426-510e202d8a03">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a0b37e40-21cd-4f65-864d-757502d02007">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8c25f990-9870-45de-a109-d5f1736fceb4">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_89a53b7a-df14-4bee-9c4c-14cc4bc2bd66">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5ee2147f-5955-49fb-9668-98b64e661631">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_27665342-9446-4b53-8347-7c7d574cdd7a">Prescription Identifier</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_37bf18df-e4f8-488d-90a1-f99d9b9cd414">113516</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7a922b2b-4452-4377-8de3-63408a37bd70">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b3659680-4f30-4907-839f-ed21ac83b51b">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_862ddad3-05fa-4cc2-bfc1-a4154599304a">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0db0f5ce-c49d-4ed8-909a-723a79c63560">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_15885af0-9c0f-47d2-9dfc-9d340c92b1e0">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bdf667fa-ed21-4210-af7d-f3c69a99a9ce">Prior report for current patient</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_64669697-54c8-4f25-b6e6-0bf8eff8d2e3">122075</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8e64c9d5-f581-41a2-92ef-ad0f3a3307fe">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4b8ae12a-c1c8-4ac6-a34a-539c7ab9ff1e">COMPOSITE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4744d132-92b4-49a0-a788-d9b623321d5d">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_17b35057-6722-4cbb-8deb-00ec6ec766b0">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ddbe5b63-b83b-4f21-a077-263d0408326b">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3054608e-288c-4c4a-9965-2bd003db5c31">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_00329289-f53b-41f5-86f9-08a734f3aba8">Procedure Action ID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_834312d7-6d24-4ad4-b6bf-7b180d66f1f1">121124</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_62cffda2-0fdc-4f12-9539-4bbc83333d9f">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_301422f8-77fb-4396-9f95-652b25283351">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3a34a5fc-b29a-4fe1-85da-1725da559ed5">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e3fa8a03-1a71-4083-8d5b-85e47ce5b720">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e37f4ba1-37b6-4c19-b5ab-6a58c76bf22c">X/D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e6d276a5-61b1-4987-80be-058f9c37e840">Procedure DateTime</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_94c67e86-e820-457c-b9ee-f25607caaf15">122146</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8402cd02-9e96-46f1-ad95-684867a2e703">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3e0aac7c-1132-42a6-83a2-974cf2eb49b6">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_127c52c9-6f23-42e2-ae40-5ed07849db7d">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_552fc199-afdf-4aca-b2e1-eea23638ea30">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dd19fec4-7758-488b-91b4-4844b519940e">X/D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_42b55e4d-3071-46e5-bb04-6bd956814d62">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_980a2823-d9a9-44aa-aa16-58b8db3c720a">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ad358d61-b1ba-4186-bda7-6833199193d0">Procedure DateTime</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1d4e7716-ea56-4b5b-aa02-1fa118452c47">52</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7666ce06-344a-4f41-9c09-b38d6729cb97">NCDR [2.0b]</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8ac6ee90-158d-4aa5-b2e8-191dd454da34">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8d550ad5-eb4e-4f91-bf75-8be598d82069">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_28407322-1b5d-482b-b779-3eb9f7b0bbfb">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1c80ecd6-756a-4801-abbf-4f68c4baf4f0">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0b219f88-c7da-4d74-880d-1b3ede224bcc">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5a2aced0-48c7-4243-95d7-30229b7706aa">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c4791c0c-d966-4a17-9be1-d9b9e88c8580">Procedure Description</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b95ca6fc-a821-46e0-aa45-d3fb5bb7c60e">121065</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3f1531fd-8479-4a06-bf34-e5493537638b">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9483330f-c074-4513-94e8-ca97523bab0c">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_afaee6bb-b828-49a5-937e-6fc15b726a96">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1fd700e5-9556-4831-a3a4-7fed6aa979aa">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6dbe7ca4-e1cd-474f-8f68-dc78a250dbe7">X/D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8e386ad3-fa98-409c-bcde-1b9049de51fa">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d20577d1-9577-433b-8b54-225e08145a5b">Procedure Number in this admission</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_59feba88-890d-4d38-9705-d5365cef0387">53</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a7641f9f-0bc7-4a9f-b3b3-469f7278074d">NCDR [2.0b]</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_60e76704-3cb1-498e-811d-4b5155e8dbad">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1c29f375-0c64-44be-9086-60d8d431ea4c">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_624aaef5-4780-4d9c-b8fc-f5dd306acdcc">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1b5a4b85-5ebb-4ecf-8f42-207ebedbc504">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_24df42ed-3baa-4c09-8e93-9d3fe9766f89">Procedure Result</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_df05d6c6-32c0-4f88-83ce-58dc31973d93">122177</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7a9ee5c4-a087-43d8-b6a5-2497ac954f8f">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a410dac8-83ed-4fcb-b010-92b8db60e895">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e7071982-7e10-479f-b104-78065e9ac436">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bb2ac0fb-d9a4-41c5-86e6-3539691e1df8">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c4b447b1-4935-4ae6-919c-29279b7fbae2">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_698d941d-8e09-434c-b469-505acd8fff16">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_05a94e9c-2b16-421e-bb55-2471de3bc1b2">Procedure Study Component UID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e87b1042-4197-41b4-8e35-f19bf058a576">121019</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6b75d8e7-65eb-49ce-b438-b0abcfdf51a1">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a4a71744-2f42-47e3-bdfb-dea4d7d25efb">UIDREF</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_aa73d2bb-2496-4c46-bbc8-9cef5719072b">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3dc7df38-e1d8-4ac3-860d-a09bed6bb3d4">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2d133235-a2e4-49b4-921c-ffc30710c7fe">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_129596c6-c453-489a-9a37-3b9cea66e794">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b24f81a5-84a6-43ca-861c-535711f31795">Procedure Study Instance UID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ffb0dcf1-a0da-4637-9dfc-0d030cb8e2b0">121018</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_998a3566-3c6a-4188-a494-56a71440eb7e">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_30912da2-ca08-4135-b44d-ed7f42c43516">UIDREF</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b7b68c41-a09a-4a61-8448-6d76fc1abd67">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_49fe2ab5-4c89-4742-af7c-102a31c16d68">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_59bbaa00-ac0b-46fd-b767-7a478d6cab9a">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ef0f93f5-9d8a-4e4b-be0a-1962b8530678">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ca64d786-3c28-4eb5-8749-3630db1339a2">Procedure Time Base</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_be6c0b64-dffe-4eb1-bccc-4ba50e4814a3">122701</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bb20f026-467b-4878-861c-0f83eef401a0">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4d48d5a1-8e90-4070-8711-1b49c3d4594a">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_84624d27-483b-47c3-8cb1-31664474c7ae">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2c28cd7a-c56e-4f74-b223-2b8fe78ed18a">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b356be28-6fa1-4f0d-9dc4-7de6a4a15f8b">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_432d085a-c791-4274-ac6f-374ce80ce99b">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_35757243-118b-4c07-905c-b6daecd0624d">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_96a48d78-92e6-41cc-882d-6ec053e96604">Processing step description</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f5aa98c4-fcaa-46ad-aae5-5be93d6f340b">111703</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_960d3769-e2ec-4f07-9005-35592d1afaa1">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_30f59304-7e80-4745-9254-2cdaec8c2d93">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_acdcee15-d791-4012-bcbb-b9c734ba41ee">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e1910df8-c4f1-46b2-ba6d-225f18fd38c7">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8d4791bc-563c-4142-800c-9fef36bf0d63">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_469fec9f-a4b9-472e-9ea8-8e36ac4ee32a">C</para>
                        </td>
                    </tr>
                    <tr valign="top" xml:id="tr_pgg_lps_hfb">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ba66b579-3955-4399-b1fd-75b032aae358">Protocol Time Point Identifier</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b23098b2-3afe-4659-a55c-9e95917d2f59">126071</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a7a1a58f-5460-4cee-963d-c3ef7b865dc4">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a9ca7c25-9e7e-45e2-a71f-dece2de5b992">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_513fc16c-0c68-46cc-b1a0-1b13399475a6">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bee8d221-b136-4b73-96d3-6cb3bf041fb1">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a88682a2-830c-4eb2-966e-63bb53483c4b">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_33722ec4-6e1f-489c-a85f-08f47f4f224f">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d51d8fe7-e84c-49b1-9979-9518ce46569a">Pulse Sequence Name</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6894c56d-59e1-47b3-8c83-528c1e6b4413">128230</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_628495f4-6de4-4c0f-989f-3afbfdca3fb2">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3e32789a-5722-424d-b617-573707ad7adc">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8a16282a-eafb-4cb6-8e6f-3befefa5547b">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c5010b14-def7-4204-b360-e178cd554505">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_de8c1c25-4f4b-49ad-a6aa-65399ed251c7">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_943d5964-a0b5-469d-bb7c-8f966ccadd68">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_fdbe713f-4e10-468e-b594-e5e9f901aa1e">Quoted Source</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b230f942-be84-4857-878e-55b13bb65c6b">121002</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4c6d2d68-f0c8-44ae-a0c7-2b4e17a4bdd7">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9d03ed4e-16fb-4ec5-93e8-bb8b82a88652">COMPOSITE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9ba1e350-af22-44e7-9eff-d37a507ea5a7">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5c5409ca-b7cb-4112-900c-ef8519f4490d">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6f4e1189-c7ad-4256-8fe4-15b3a6cdadb1">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_673106ed-e3bd-48a5-ac6d-319cfdfa5cfa">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c6dbeecc-ea4c-4727-a7bd-4c16ac46f4e9">Radiation Dose Composite Parameters</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bc19acce-7aac-473a-b296-77b3cf5d825d">128436</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_131d815e-63da-4bc9-a741-f53f5ec62eb5">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_59b16ae6-2d0a-452e-bcf3-b5f1bdc7c06f">COMPOSITE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_abe9fc59-61e1-48c6-b091-bbb1e8654ac8">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8651cab7-6888-4ba3-b5a7-89a02691befc">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_563360a3-9ce5-4c22-b792-b40d39d19cc1">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2c86c48f-c066-43b1-b30d-5a3e1deff354">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a2f6b49a-9c24-497d-9ac0-3def269a5161">Radiation Dose Estimate Name</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bc2c4454-8bde-491c-940b-ba7d65a9455c">128403</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9e2e005e-c22a-427c-bc53-47ed4eb0627a">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_624060e3-a8cd-45b9-8884-cd9cd6350e36">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_713a8679-3376-4290-b0e9-04de2ec95a51">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fb97cf95-d25c-4c25-984b-11d90086359e">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f43c76aa-e771-44d4-a33b-7037ae61e95b">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f19348e4-0c2b-4cf6-8038-434560ca8042">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0748b456-511e-4a24-80c5-97e8da58d25f">Radiation Dose Representation Data</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bd0efd69-0a76-4d8e-9731-09ef723f86c8">128414</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_159bc952-c559-4765-9680-b0b9a7ff3f20">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_050e100b-8600-431d-a590-bb78c7a3b57b">COMPOSITE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3580cdf3-8e93-4eb9-b005-e8d5fade9286">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9aea6a2b-8df7-4e71-9a4e-162229512ec8">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_053983a3-9071-4dd8-9d5d-cba913953d13">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_021edcdb-a98b-4ee8-9408-a1754c149369">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_55ee0ad5-a80b-49eb-b50c-8911ad8da7e9">Radiation Dose Representation Data</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4f2bf909-7888-46aa-b498-2f614587d969">128414</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_750c88bd-24dd-477a-927c-693ebec8860e">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_919a44f1-3871-47ed-913c-95f1222e9b44">IMAGE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_38eb1ad8-3c39-42d9-b71e-bc7deace94ca">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2fa3550d-af4d-4715-9ac0-5b9dae135722">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_285c1fca-652d-4e3f-8729-af3169525984">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8850ab42-f42a-417c-a1e6-a97a51ce561b">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4762e340-f946-4527-926f-2ec552cbbc08">Radionuclide Identifier</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cf1aa812-d04d-4c17-bbe4-c7a5f93b7df0">113514</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_99968ca0-a58d-467a-ae0b-5072dc46617d">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d7faf881-ab2f-4546-b829-8fa7cfd77230">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_03ffb9d0-d1b4-4de5-b0d1-a0c9b1150c94">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c1aac705-daaa-4b54-9f50-13d96966cfa0">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9ac809c9-7ca2-4558-a424-09aa25ce5acc">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_38580679-db2d-4218-9a5b-c5d10b6733a6">Radiopharmaceutical Administration Event UID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c4700da8-c591-40f8-95ca-1c1714d526c3">113503</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5f1d914d-e078-436b-a899-d4ebb90b6dde">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2e710f45-d828-4689-9676-c5e8720f4bf7">UIDREF</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c49ba7ed-715c-4af4-9a7f-c5be9c5eefbf">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c3437ed7-8138-4adc-a547-ce9cf4e2404f">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2356529e-505a-4126-b9fc-62d8e29e10df">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3e161bdd-3a6e-4ad3-8048-efddb80272ee">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_098d4177-7c12-419b-b254-a02570241e3c">Radiopharmaceutical Dispense Unit Identifier</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8ecb5c6c-5945-45f4-b802-3215f777aa80">113511</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_00c489c0-e8c8-425f-92ff-2e1d588ab91b">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_08d51e3a-954f-4751-88fb-196484640b5c">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bcd62832-52bd-42c7-93db-b17d971007cf">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_777407ba-92b6-4ff1-a338-5c5321cd5ff0">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a1dea68e-64ab-43f0-80f4-2d0b050c93de">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d36463d0-0020-4715-a927-16780933a33a">Radiopharmaceutical Lot Identifier</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c504fe7a-0fa1-499b-b07d-5776303552b9">113512</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8582d524-2801-4271-9172-c0fb5b4f7745">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_85e14e06-28ec-46c3-9419-613a2ac09009">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_be89fd37-f89a-4f19-bddc-32aed66c31d2">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d19e95a7-e2a7-4463-96ce-32b8a5f7847c">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eff2d0cc-dbce-4924-a8a9-cdf1412a3858">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_be7a9fce-6c55-47de-9379-5d5df19f8b86">Radiopharmaceutical Start DateTime</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9123b578-4fba-4591-bad5-126d96df3cd4">123003</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6537d061-e091-4022-b2cf-f54e2433b63b">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f7a25d98-adbc-405d-bfbf-5a6e79b84fe2">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_204fbbfc-9f14-4169-8dfb-be67e648544f">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_405ace16-9643-4625-8cb7-bba54cd21c76">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2a3abf44-5573-4baa-94bd-b94018b63401">X/D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fe2f97a1-b971-48c1-a27a-66af453db8e3">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b79d42b5-c51a-4bfa-b15e-45a83482197f">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f520e6e4-a006-45da-a93f-60dfe9adad46">Radiopharmaceutical Stop DateTime</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2a24fd9f-7d02-43e0-9b4f-e8b82657017a">123004</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5eda4eb5-a19e-4ed6-9aef-15cfb5491369">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_10b42a85-51a7-4016-a187-ac0dfc93f2da">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e09f62a5-77c6-4afa-99ac-1796cd8e40b1">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_74ebcb30-00b6-4c23-b806-1ef00f9c8e87">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ab5a342e-6e1c-4388-84d4-dca5cf529942">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5ac2759f-53ec-4c2a-b350-fb84e6b1a275">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_03632002-78ad-402a-a006-e267c68d0aa2">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f0e70e33-2f42-4979-8dff-162eea37abed">RDSR Frame of Reference Description</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3f5ca160-3ef7-4a39-a919-48e7e391dad6">130507</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c9f0697f-b066-4162-9ca8-c19a6f06b1f0">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_edd92cc3-c0d1-4746-b879-79f7d6ebbf7a">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bc6979da-bd55-4ca7-95ea-4e7eac059b6d">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fd481737-376d-4078-a421-9ca88243ee07">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ab171aee-6d17-4e52-8775-6c103a7dc569">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ea28db91-5296-44f5-9f95-1c3190954474">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ff019f32-45b7-4b00-92fb-9d5cffbfb687">Reagent Vial Identifier</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f488bb09-030b-4baa-9e5a-dccaaf68cd8d">113513</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_776a282d-a54c-4813-ab87-7e424447ae6a">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_250b8591-4871-4daa-9b9a-141602b915aa">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f100c6b8-3ec5-4b77-bc9b-bc5404fb9c6f">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_389468da-8291-4e69-91f9-73ca12076f6d">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9dffebe5-bc1b-4d62-a076-e08f8de0b3ec">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e5e90061-5051-4adb-ae44-ad45542eb3c0">Real World Value Map used for measurement</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0654597b-2f07-48be-8caa-3eb4d6a83aa0">126100</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a6172df1-98dc-47e2-b2c5-9a742fd7e5ec">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_67ad4c09-c0f4-48e9-94ea-d82f63319f00">COMPOSITE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3fc88886-acc2-4252-86ad-237b550eb629">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7aa53398-4f1f-4278-a756-8c3479b755e2">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e78f41c8-2ac4-4c49-be81-3266bea2b3d3">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6d82b324-be00-4fa9-97cc-9ebf4545e2ca">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b27ac49a-cbcf-4825-bd2f-17a3c77239ad">Reason for Proceeding</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4b8bd497-b401-4e7f-b874-948ac6ac077c">113907</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fc749a04-7933-4afa-ba96-9eecff5a70b9">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f8cd306e-7d0f-4d28-b4ae-668d02b2a7c1">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_930a6818-ed8a-4491-bb4b-f8e6df1f7b89">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_34af66c1-0e04-4042-a807-2e810425eb3a">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5781fe19-a97f-446e-b5ec-ed08f8f93387">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2c8fc433-a1a1-4e03-95e0-0ac971fe94bf">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_aec1976c-2e91-4f53-a070-ee11813aa6c0">Recent Physical Activity</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_416a44ac-2a1f-48be-9cb9-9a242335eeaa">113552</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5b3c5420-ea00-47ff-85c5-6026ca8fd4b2">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_85f327ef-aa1b-4e8a-b248-28ba6dd0e039">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d0ba29b2-9397-4e39-b560-7c55343f16fd">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_133b9fcb-8349-4da7-9090-a72dd96d8e4b">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d11c5d2f-4153-4232-9476-c8ccce4594a2">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_34a3a9a4-1d4e-43e2-9d0a-0ef01fc1c54d">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bcb56246-f8e1-4cad-8ca5-2f768d1b239a">Recommendation</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_64391d9f-0d3c-4f1f-ace1-e58fb0d12bf6">121075</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_08097f1e-2025-48c2-9da3-f2a354221b01">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2875e3d8-86dd-4e87-8bbe-d8474196c639">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_03bbc477-c7c3-400d-9c97-61f6f307a06c">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b7c22d8f-18be-47f4-89b8-bf025718a80a">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_08aa11cc-f65d-4abb-bafa-6251147a9af0">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5c92a2fb-4463-446d-8ec2-6780c0991e07">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c05b552d-c977-4154-8695-7f1edd2176b0">Recommended Follow-up Date</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8449b470-e1b7-4852-95fa-395201fa074a">111054</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9f9171a4-c80d-4433-a28d-0da6cc7c4a87">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5abc52d9-9845-4550-839c-2ea2d29747ea">DATE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_aae09dcb-2e01-4bab-bf12-4e5ad75b7051">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_390ffa6e-c0d2-4374-a71b-0d7f63d3ed1a">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fb6358ab-c353-49aa-a942-660629a29008">X/D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_293dc255-eac3-48f0-b16f-2c4e56877520">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f5891a77-ac9c-430c-8669-7a39d4071ac4">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_33f1cded-4545-4da9-b683-d2d4b2a9b21a">Referenced Segment</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f0b495bd-e9dc-45c2-8d2c-235f82a81ab8">121191</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_79acb859-2541-4da2-9d4b-dda7dbe573d5">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_02916c48-5d40-4705-8cde-72f7e3a2214e">IMAGE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d2b0c413-887d-4707-850b-fb9a1ee44dc1">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7c37f10c-cc90-4360-b169-103f29dd5e42">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_86f8f043-2740-465b-8566-fd0fe3651aa4">X/D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a28ce76b-6ece-4ca8-888b-84088c5295fd">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_716e370a-5aef-4983-9c1e-6ab9c74cf469">Referenced Segmentation Frame</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_10755921-c308-4dc7-881b-00f05edc7d74">121214</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9d6f9b0b-e714-41bc-ad5d-c9a4bf7e746f">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0767b9b7-397f-454f-ba13-a613b94598d6">IMAGE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1a8f2157-fc08-479d-96d7-97239f28de2b">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4d17f707-74f9-43f5-b395-d8456fb377f8">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2e8dd3c9-0253-42a3-9cbb-96a4abc509a1">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_88bfd00c-36a3-4f4c-9ce3-daa4c17bc6c4">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ad9a3c20-af7a-4d26-be4c-275bc51fa294">Related Patient Data Not Used During Planning</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7e8603da-94b3-43a2-8049-32c0c1d88e6d">112364</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bd45bbab-e823-42bb-b929-64744a668276">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b700e13a-7baf-440d-a13b-5b99752def67">COMPOSITE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7d120ad1-f998-41f8-8559-2f0c7d8ce5ab">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a574a75a-cb15-4c07-a650-3e45e2b177ed">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_05d0bf91-f9c7-4d02-a35a-9e6b350b44a2">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d7fc5153-7e8e-43c1-b1e4-86a1e7ce1e67">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bb996e1e-e222-4609-bef5-78f6a78889ec">Room Identification</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2faae878-12f1-480d-9387-105225a06635">121121</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ef20ecc8-565f-46aa-992f-e494ff659509">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6b95fee7-4512-4bf3-b5c9-8fa06e94d86a">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d12e1ae6-48f4-428f-821e-98e378f39ffe">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2d8178ff-4180-441f-af4a-f86319579029">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_624d8c9f-6ae3-4f85-86c1-676fbdad26bb">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9870a69e-d439-4659-a2fc-56464206247f">Sampling DateTime</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_84ef67b1-b887-4db7-aa9e-6bffadfb6f2d">111469</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3768f8db-6fac-465f-b506-d4990786efe7">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8c381fc2-94b3-4246-a10e-e2682be05394">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0fc522f9-f84f-4799-85a3-1dc4888edf8e">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_072400a9-46bd-4b01-8001-972f6b410deb">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d940f218-31f3-4138-935e-ec373f4d7c69">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_81c5a525-f9a5-472e-8a90-c9199213937d">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f119e453-63b5-4dd9-bb33-7a0bc8f07e1b">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1cde649d-09d6-4941-92da-d7bcbee87b6c">Selected Region Description</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_28e886b9-3eee-4a74-9d31-1ee7af8288a0">111058</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_366cf3eb-3c16-4d0a-8904-a029f6b031e3">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1adf785e-4c36-4ad4-b3e6-647ed4e80942">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5bf22080-0105-4c73-885e-794bf963106b">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9867e5b8-075c-415b-95fd-849c3aaff55d">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a36c0dfe-27cd-4b09-88cf-1698bb76c3ca">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_77615adc-9812-4991-9953-cb8483cfad05">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b184242c-ec85-4ad2-b0a5-1a224b5f6b59">Series Date</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eaf5c96c-774e-4c4f-a15f-5a71f92f2b1b">131561</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e01f02d7-0c69-4bc9-990b-48c2286a87fa">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bc398da1-83da-4247-ad98-f424fd9ecfae">DATE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d7039de6-79d3-46d8-9526-d0c1450023e9">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4ceeec69-35cb-4259-973a-ab7bca771337">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f04621da-3fe7-4a23-acd6-abf3ec41c28a">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b097eef2-150a-4da9-8df4-44369609f0b8">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f1d0fdc5-c1fc-4ccd-809b-6bf8f87ed03d">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_dcd83b45-c82c-492e-9f74-8a3379ae1ba6">Series Description</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e4deef19-9d01-422b-ae88-e484a2887678">131563</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6c2420b1-6265-41c1-ab08-386246089bc8">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b25a6cce-17b5-4ca6-9f78-58577a38bf03">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3253faff-7f3c-4e57-aa64-a7604a4db045">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b306a2d8-e96d-4497-b3a7-ccbc8a6d779e">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e639af39-1f43-4e53-ae3a-82e4e6729782">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_22a970c8-de2c-4ca0-99a1-f92e46b09aff">C</para>
                        </td>
                    </tr>                    
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8ef03ac1-599a-405a-9f8c-33c63c4882e1">Series Time</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_867cdefd-61d6-4783-8ad6-3e1503add406">131562</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2843557f-4a8e-4a49-8ee7-767a9dd02850">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_badb9ff5-487d-474c-8c03-9697f4bd5f8e">TIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_578dad27-ba08-48c2-8349-d3212139d04e">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4637b3a7-2db7-4717-bd8c-74f1c3ce7690">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f933f308-9a9c-4928-aedc-ceaeeeb8bd41">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_45048644-6b07-456c-a77d-b26e6424c9fa">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b617118f-980d-4b7e-bd87-f4cac20fb916">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4e73e861-9ab5-4dcd-9e64-8038ccbe2e04">Series Instance UID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ef86f07b-f932-4547-aae0-93ff071d7adc">112002</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ec166fd3-368a-45d7-98ad-b7e62b6eed1e">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5ce0b5d4-bbd0-4287-8daf-d64500a60b31">UIDREF</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_175a5132-a082-4d26-9d7c-e0891eb165ba">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e5ffe2a2-aab8-4aca-bb54-153df760e218">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d086c0e2-d8e8-4ca6-a2fa-11e4ed9af455">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d2e689fb-1c20-4472-bce5-f704f3ceda93">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8f16dce8-c800-483c-ab0a-1dd0141d77d1">Series or Instance used for Water Equivalent Diameter estimation</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5e735b72-b640-4577-bdbc-3cd6d8ee436d">113985</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eef54204-9a5b-4ca3-b3ed-f218222d4008">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_19367f10-e965-4a53-a6c9-c32edd758ae3">UIDREF</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_82c0b620-cfeb-45c2-be86-12f03ab05e96">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_96a28015-9d23-45d7-b0ee-880c0a4e2fbb">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_66399adf-0b7b-44a8-9636-443d48b3c615">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_de3d3bae-f253-440e-9367-a625aca10b78">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a78b9238-0d23-45cf-81fe-aaa45b290126">Service Delivery Location</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1fdc817a-7d51-49e8-8fb5-f4a66a10932f">121434</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f384832a-47b7-4f39-ae22-b41f6e30b819">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_58cb40ec-d017-4664-aa2a-e2a44ec73252">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_24c1cbde-c6ac-427c-813e-67115419545b">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a18a159e-db4a-4cf4-8e05-829dca952b32">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9250bcfb-86ea-424d-82a2-b4836211e1fd">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_19c9922f-7647-4c32-a7ff-3d72996c08d3">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_37bffe5d-842a-4368-bb61-e797b5aac7a6">Service Performer</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_16dc272f-cbb6-425a-952d-218b87325366">121435</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ca3a8657-0c66-4f65-b090-08caa56da9ac">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e3e4c5f5-c3dc-4fd7-a845-6939569e11c4">PNAME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_98d10a00-24f0-4ee5-b699-6e15718b57bc">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d9c5ac49-c033-4482-bfe3-cb2062b98497">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4f2393a1-dc3b-455c-9aab-6a3bd9095ee8">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f1afdd76-1b44-4c2a-b0dc-6b9e6aae913e">Service Performer</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_db35f8c5-0d51-4a07-8017-fed81a1109f0">121435</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_810b1720-ff51-494d-af99-c563854e55ae">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ece66e62-954c-4371-b663-034f8340f232">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3a0df267-1ad2-43a7-9777-3a3fc3639d96">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a729e6b6-5eb9-42c2-a5e1-dfa12d1c4cf6">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f97c0422-e07c-4247-acb3-31aca9c5f871">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_edf6ede9-527c-40d1-b86b-2e91f4af6608">Social History</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_79f54395-606e-4fc1-908d-6ee1f005c967">160476009</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e9fde1d4-94ee-44d2-8825-a4d326047f4d">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_600176de-cc56-440f-817e-2ca3701292b0">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_89f66cdd-3bdd-4fbe-80bb-febf98833f4c">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5cd885f5-3344-4bfe-8ea7-f591adea457e">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7ab1eaf0-41fd-4773-bf9c-bddbd57d7ac9">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7aa85c36-d7b9-491d-9751-3650efe0abf7">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_642ff950-307e-490f-bb36-0a7346cd99ea">Source image for segmentation</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_90b22ad1-d92c-447a-bf2e-86f17ffd1112">121233</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0cde46f9-6b4b-4da6-9588-4bed7f0750b7">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b8c89736-8910-4ce6-986d-a5d3d7e1e11c">IMAGE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d1c71881-174e-4b70-a0d8-2dbabe28675d">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3eeae47a-5d0a-450e-9fde-3ede546590c0">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5fc34e65-6669-4b83-a196-370f02b5ec08">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_81ae0d8c-39ef-4e50-ba64-259c27d423db">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_cf54685a-0c6c-444f-8c41-9c8829661ae6">Source of Measurement</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c6f2ac3c-dde1-417c-bfee-4082e046d586">121112</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d29c90c9-a944-4d14-b220-137dd6ac02b0">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_251d9142-9531-4f87-b78c-f0717d4583db">IMAGE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_aee1ad32-dcbe-47e7-ae56-9c900f18545b">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d2320d42-0d6c-4890-824e-0ba8e0e0a340">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cd505118-d3f5-437a-a4c2-74d41464d474">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_58ad8226-a09a-410e-8b8c-f64fa8faf127">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8764f30b-c1a6-40e6-9a20-f22b95f3b318">Source of Measurement</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_23516fcc-3345-4997-997a-e0adb03a6aa0">121112</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_76397e33-e7cf-44e0-abfd-c026d2680786">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7c48decc-082e-4dda-b5c9-2d22812551e5">WAVEFORM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_38c7e52d-694f-43ef-be89-e05291f04319">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4da223a4-ae4f-4315-a847-47bfc973e4a0">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2e505c54-ee19-405b-962b-7e581508e97d">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_be7cbb54-3eb1-4f94-82d7-3986250683fd">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4efdb719-1b7c-43ea-a713-21bda72b2185">Source series for segmentation</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_005b07e1-6c13-4924-a82a-d3554ffc916b">121232</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_52aaafa5-1f84-49e3-b951-127a649972a1">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4579c550-21ed-43d9-8717-a40cb996819e">UIDREF</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_767b4cf4-8af3-4ed0-a798-a79f494e1f07">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_910c86ef-81e2-4fbb-ae99-865730c76272">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_33493bf5-fecf-43f9-8066-0c7d1b803796">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f07da0f2-f691-480d-b791-6ff95410e136">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_aa461889-1fa3-4b77-ad0f-f0bac3f47f04">Spatial Fiducials</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8866f417-72aa-434a-813e-3843b6b051ed">128447</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d5453c9a-9a3c-4fb3-9494-aabca32f49e6">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_70ff00cd-867f-4099-b657-4d875d54a28e">COMPOSITE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_710e1b20-b3de-4cf6-a627-3d735785897a">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1d7084d5-eac5-4b00-8b56-c53dc52b3773">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_385679dd-b8d3-4eac-ac33-3274deee8c38">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ef483487-776b-4487-823b-300ad08e5920">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_42f525b6-c67c-4af3-bbac-f1c6c1d0ec5f">Spatial Registration</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1d3970e4-0822-4e60-a1a5-dd03fb58d58a">112353</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1b9adfae-318a-42dd-96c6-77f386fd5734">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_de07465b-726d-4c9e-b43c-5e16849e2c6b">COMPOSITE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5360349d-eb23-478b-b3c1-33faaa1ca716">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_97a5601e-c1fa-46f7-af10-b107e0f2574c">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_34fca2a6-bd23-449e-a53d-599558f26a39">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e3f0114f-4e73-40fa-af3f-b91a97b63f29">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_689f920b-f557-474f-b014-d146e4d5a12d">Spatial Registration Reference</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9f1db6d8-6ebb-4b54-9299-c2aede5c014b">128444</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3b16ea4f-af62-4e73-86c1-fac845094758">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bc4ddb50-cc01-45eb-ab5d-a2a677d83b22">COMPOSITE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0cfd97ba-17e8-49cc-932c-31b8e5c6770a">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0ce250a5-2869-446c-aab6-604b1043a8ba">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b406a76b-334c-4701-8f0b-d4ab253869fb">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_834833d6-4442-4754-aac9-c73cb2423580">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_88788a7e-3e0f-4325-b849-f1f069a15a85">Specimen Container Identifier</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ef43adfe-deec-4913-9803-310cdf512084">111700</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fe61a6f2-1977-4a89-a1f7-ca88faf78c65">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c20a938b-fe5a-40b0-aa28-f93ba13d8842">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_24ed91c5-b1e3-4f10-b714-5b8aebf44fe1">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ceb1f268-9e08-4ffc-9780-a3517c05832b">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_280e4056-325a-4df7-8896-8b9504006577">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_fb6ee597-f971-4d9a-9e49-d926d33a6530">Specimen Identifier</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f1d19e23-281a-49db-942f-68c9d30622cf">121041</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_383224b8-e4ea-4a90-8350-36ad513efdcc">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_446752f0-c23f-4d9d-a9af-93ee31c4a587">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a6ecbbef-281e-464f-a149-42cf5a1c323b">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3bb6e224-5c39-4b09-b8e7-7cd1215db8ea">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fe4ebc2c-80c1-49d5-bff2-c2d600ec2434">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_fe8a6dc3-2a10-4319-be0f-37322943b3f4">Specimen UID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_391a2af8-cf15-44b2-92a8-e826e95f786e">121039</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c7be1c7a-3ac2-45df-805e-66460af0070c">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_70519ff2-e827-469b-85ea-941580b6d279">UIDREF</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_79916e71-5ccf-476c-9656-c0c40b47d022">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_81a83dc6-9afc-45bf-9f59-248146d304c4">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6618581d-5ab0-4032-9668-4bb2fce70fb1">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_68ca26ef-7b04-4f20-a87a-fbbe062fbac8">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2cd180b7-35cf-46db-867c-aabcf66dd676">SR Instance Used</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bbba39b8-e39a-4fa4-a2b1-d820488bbc14">128416</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_14d95f95-9ecd-4e80-9a30-d37af5506aa9">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bcea6653-8501-4358-b5aa-3f9f7522c066">COMPOSITE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cd67837a-f76b-4306-9c57-a80188422ff5">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6aa3ec14-8ea1-4eab-8e3c-8560b707f6f5">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_59a2ce79-e425-418a-bf84-4522386133ed">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fe20a0b8-0754-4111-b4f5-87835fa284aa">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f8a516c7-23de-45df-ae97-98f38290e6ae">Start DateTime</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cab059a2-6238-44b0-8262-a977367300be">398201009</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_52d28c18-fd29-4ed7-8714-975619a0c938">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7e13224d-1097-4db9-8127-a710ec015e2b">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_83709b22-099d-44fe-adc7-5b640f66bcaa">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cd8d20ae-f46e-4651-b1d1-857ad07d872d">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0c9cd674-14aa-4e9d-a9ca-5d04910f9438">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1abebdfb-3b95-4212-b674-b72300021f53">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cf661694-08c3-4bc2-b39b-babd40c602a5">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7f7127df-3a50-4755-a2ee-2fed293cbb12">Start of X-Ray Irradiation</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8717f384-e774-4792-a866-10624e8202e6">113809</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_75c60c43-f494-408c-a9f3-630e3b1bc928">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_43f633d6-de6c-4b44-8fdd-abb3dbf6a402">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c1098b6f-728a-4bcb-a8b8-552cbb696737">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_53153182-cba5-4e1e-a81b-9975c206989a">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5524f887-8abc-4e89-8ce1-70e8af9eac6b">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d7ce01ae-cb67-4340-ae56-d24f47f5d187">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d4ed9c84-ebef-452a-b688-8cfc062353bb">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a2d8be7a-1778-4f35-8378-b1cf4cfd346d">Station AE Title</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c66808c5-b21b-45c6-b4ae-2baad5e869bc">110119</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c212bd11-964e-4843-93d0-317df42767f8">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ce259f61-f3cf-4e6f-8345-8b5c2150d53e">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9b6dc221-ef09-4b40-b581-d0262c55890d">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a42e1352-2c28-4eb1-9174-76001c5e1709">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2c1664e1-686f-4789-9216-9e92ea5bc148">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_47ef84a6-72dc-4bae-8281-2836e7f13b45">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4572e865-f58e-47d9-88d1-63ed479342f1">ST Elevation Onset DateTime</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_312a5c93-91b6-439c-9123-ec887e14cf2d">122173</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e5b49b81-3886-4d4e-a223-1155df7e64c3">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8d8f48b2-b9be-42d3-bcad-146058ee2a50">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e9a9b22a-3da1-429c-baf2-80d67155200f">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_79a2f095-94eb-4fb8-829c-bac3bc8d5911">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c56ea19f-e6ba-4499-b052-efce16a94976">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9093c2c1-5a6f-434f-9463-2404c265e1d2">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_99c13896-a89d-45a7-9c42-c87c4c751252">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7ad621ac-641d-483c-94a4-782b50d97277">Stop DateTime</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4a73034c-76a7-4758-a65b-d739d50aa448">397898000</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a174fe91-7bfc-4183-a539-bca39061eef9">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9514090c-b7e5-4685-bfc7-0665af96ea2c">DATETIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2212340f-c447-426e-a6d9-d254bbe68d00">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_44b109ca-58a0-4953-90b2-a4eadae1ca3a">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3ee98823-bca8-4139-94ea-42caaad71fbd">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_71269007-3d74-4a56-96cb-dd3e537def9e">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2a924934-f0bf-40f0-bb19-ee89abe152bb">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_782eecad-e394-4d71-be0b-a5565d4ff2a2">Stress Protocol</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_86e51793-4e15-401a-bd1d-823fa7aa8387">109056</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_21e51a79-4fd2-4a29-a038-035e9b18cd1d">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ae4e4d16-d8d7-4667-8dc7-51734d9b0007">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8d9c3f22-86d1-42a9-8dbf-1d2e972b8240">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2a77b22c-c29c-4100-924d-147f95f471f3">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2ffe1aba-4c87-4004-b9dd-0f0b2de8fba2">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_28283f7a-e951-4858-8127-39d432a2885e">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_084165e4-df40-4e8a-9125-804ab2239ccb">Study Date</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d2412ad4-a0fb-4694-98bd-133267eb5320">111060</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7323f384-2426-42cb-9f48-e136497af87f">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_939df60d-2e11-4cf5-aaf7-c8748bbfa000">DATE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_19f998f9-a999-40c1-8cad-3dc06129545c">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6baf42c5-a458-4287-bcbd-2a186f95ddc2">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fa9c82a3-db94-41e3-9bcb-e28f38b88300">X/D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_14d00fea-7898-4b9d-8d5f-f305f7f4df5e">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ad328d6c-d350-4e27-866f-bb42088e3ce5">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bbd1f802-0d9c-4baf-9bbe-31bc2fcfd39d">Study Instance UID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9ec3e6dd-7fa6-4700-879e-16d2e9b374b4">110180</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9c74d70c-0dd0-4e08-825d-297cf453f458">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9c0b985f-f1af-45d5-904b-1433e9be1b5d">UIDREF</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cc35c685-de65-4342-8c7a-a84d6a661f5e">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e82583aa-db33-4e65-9cc9-bf47f7767977">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_23849168-605b-4606-8c41-81b869805704">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1d10826c-827d-4a8c-993f-aeda5049d76a">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e763f83e-90be-4a26-89cf-c8a0f441e17d">Study Time</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5d8412d7-b50a-443f-94cc-f597ffdeebb2">111061</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bc00da2d-5171-475c-8284-1bececaeb3e1">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_39504f25-3998-4163-8276-cc0af9d3c034">TIME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fdbf97ca-1f98-42bf-87a0-bbd5ccbb5c9a">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0acd44b0-ba9d-4206-bbd4-409f996c8df8">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_21a3437a-992d-44a1-a332-552145380582">X/D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c3128624-214f-4e65-a3f9-00ffac89bf96">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8825c02a-d4d1-429c-adde-cb28ec2d93fd">C</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e2ad4478-5e78-4e1e-8529-80a271ea542b">Subject Age</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_92871b33-4c08-48f1-a823-e7d0a34248ff">121033</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e4af8792-38a0-426c-8a07-e1bcefe4aabf">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f13223f8-2e75-4847-89ed-5c7aeae788be">NUM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7db2d884-3a35-4e7d-a100-acb15e931797">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c8136b43-3f18-4871-ad56-219d6025f406">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_09799bbf-db27-4ad5-9980-05503cbd4079">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7762c3cb-9733-4b62-9a65-c3b4f1e97ac0">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_dc395bed-ba19-4806-abab-cb3e9bdf7b4b">Subject Birth Date</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_abeb9449-2e52-410e-ae02-0afcc876529d">121031</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_92d6a8cb-42c8-49e1-a95c-181b1f935616">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_df5525bb-78f3-4424-bb04-db60722a8a45">DATE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c52fb27c-1c65-473d-b8dd-34e3995abfb7">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_913e2317-4336-4733-92d7-1bd8d77eaa3d">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_12f5fb70-71b4-492d-b3f8-a96de473f4e6">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_709154fa-4f41-47c7-ac0d-92d122d9bc09">Subject ID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f2a30ba1-7956-40ed-afa7-93224ce92f7b">121030</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7b6a90ea-427b-4ef5-b9be-54345f47d5e7">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_71d7e438-55cb-4447-84e8-2c093ddacae4">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_14dcc8e1-f144-4c2f-bc14-8bd8c5c8ed9e">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c2362fd6-64dc-4833-bbc0-26af25d065fa">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_74cbf258-fcbf-4865-b816-edf924777b6d">X/D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1e6eefa8-d84f-473f-83ba-76b33ef22c76">Subject Name</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_404c494c-3c52-4820-b045-33e826f4d611">121029</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ed0a48e7-2636-4010-bec1-d80a9faa783e">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ede4e8f7-a4b6-44f7-8fdc-9fcd8292a655">PNAME</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_89687d93-375a-446f-923c-2d24421d8535">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f7d92c58-a0eb-4f5d-b483-f0d0378b15d0">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cfa1a7de-b841-48d9-95c3-dda354d3935c">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f2f92066-a155-4bb3-8165-a4bb57d7ae9a">Subject Sex</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3da3095a-2bd3-4e4a-9871-ec3c3e215b4c">121032</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f1b8ffe8-006d-4abb-a70b-1dd40dec6f6d">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_63a768ae-12c7-4212-ba04-d40250393c2c">CODE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1e1ec559-1f7d-4d41-b7db-5a161aad734b">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a2bebc31-a22e-4160-942c-630453f2d54f">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_07052f8e-dfff-43cd-a851-3949ad7915ba">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_111ff539-a20e-4966-ba28-727c6cef2125">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_beb54009-4b70-49ff-95be-861defeb7bb3">Subject Time Point Identifier</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6a7d612d-617e-42a5-96d2-bd560362d275">126070</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6021d1e9-bfe7-4743-b5d5-d276325031e0">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f942ef50-c5a8-40bb-8647-130e666ac90b">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dd922f1b-d94a-4b00-a6e4-06a1c593b4e2">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_96abdc47-6819-4c8b-a054-092e6286952b">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_41eb6eb9-f28a-402c-8f01-624639389273">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7106b337-ad91-40e4-bd56-2b2f159f90f1">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a3cc768a-7c6d-4af3-b9c0-32fe495fc4a5">Subject UID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_961029ec-5314-4989-9a2e-a1b1b13dcd10">121028</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_be105591-e113-45ef-ac03-78ba0232f4e1">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4a14633a-4a16-4116-abbd-7579b8f2e5c7">UIDREF</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_62127c82-32c3-490a-9ff3-7f36e86a35e2">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4e9a28be-6b61-4760-a1e4-e6bb83e01715">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_df74a4dd-01f9-43ef-ae45-96139ae97033">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_56c7a64e-1b6c-442b-bb1d-aff8f8a330d7">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_461d98f6-c8e8-4843-afcb-508ffc8b71c2">Summary</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2fc4a476-83d2-4982-ae0c-bf423d9765a2">121111</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fdba777a-7f7c-4606-ac82-4fb1e774ada2">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_60867852-162c-49d7-b3cb-b311b5b79584">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ca3f4ef0-9687-4085-bd30-d2e46001dab1">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_98a1e4bc-49bd-41be-985f-36b29d1f1529">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c24609f2-ea2b-453d-98ac-afb434628124">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cd51232e-4617-4092-a6c0-4225a9df5485">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a3ca3144-27fb-4d92-aa70-ccf9d6add562">Supporting Information</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e0c0607b-46e9-4036-a895-ae291b9354d9">112359</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4f9ba92a-305c-4533-9d3c-26c1fad47fd3">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9ff22648-3076-41f6-af52-29381357a3c6">COMPOSITE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ef6b2ea7-8e62-4be8-9c3f-5b5c9e46a957">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a683a2d0-421a-4967-a4b1-47fd6d273960">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_372a1a5b-d7d3-4f8a-af3c-782b9450ea26">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d4ae993c-f0d4-40a2-895f-e3643433b369">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0cf290f6-5a99-4320-8ba7-ac4b71af0d23">Synchronization Frame of Reference UID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_411c34ac-18cd-407e-8750-fd48fcbb56b7">130885</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d461250e-4fc7-48a3-ad94-62e381b7a290">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8923d4a0-ab22-4831-b06e-b76b705b6979">UIDREF</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0d1bcf92-bfac-4515-b350-add968e9622e">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3141b539-5ae2-4bce-a15d-27c9e612d457">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2cca2835-502b-482f-b16a-96794c8c3381">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4b9e6298-99b4-4bf6-93d2-d0e3c0b4af2f">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ecd3588a-4d0b-498f-854a-9f5e68b71b07">Time Point</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e80f7b23-9271-4ce0-8ff2-ed594ef562f9">C2348792</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7d39361f-65c6-4110-8e38-adf83e1ce17b">UMLS</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_33f1a830-115d-496a-8fdd-9925166693e1">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_252130fa-8a71-43da-8042-96b0643ea2e0">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4ae3c6c1-51ad-4ab8-a101-2f78e9cb3f99">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_97a1883d-9674-470e-8555-b3d95eb28670">X/D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b88b19e8-8972-4a1c-9893-08a1fd448fbd">C</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0772bc52-cd85-4803-9be0-0f133735428c">Tracking Unique Identifier</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_809c8a68-5c11-42bf-87b2-3a54d27e9906">112040</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9d97795a-2a3a-47df-a5d9-f2938e1bd016">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5173dc56-6ff1-4060-9ef6-ca3835e12700">UIDREF</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d840ccb6-936a-4e2c-b22f-90382744b85f">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4f13dc2c-7a13-470a-bcec-fafbef0efb23">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2cf31f6a-b350-462b-845e-b9bcc61966fe">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0cca5e65-89d8-4613-b8d6-abca93d7f538">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6e9d19a1-4f70-4c1b-b5ed-8f3d216235d0">Unique Device Identifier</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ec1a6323-01df-47c2-a4a0-8247f07d6f7d">74711-3</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f28f39c8-5e36-43ec-9dd9-34f6f2979ef1">LN</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d0d5e635-4aac-4c05-95b6-cdf9822036ca">TEXT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7340506f-5ab7-485d-bbf2-538ddae74be5">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2cc36101-96d8-41e3-a8e1-1c80cfc425ab">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1aa0c308-b13e-4787-b8dc-8044cac52a48">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1ae27dc9-a5a9-46cd-99e7-2f72cc6cce3e">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f46f8f93-8fa0-489f-98ce-8b8dde0919a5">Unique Device Identifiers</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5c34f6a5-8de6-40d0-a48b-ab8c70d85ff1">121000</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_63be4c53-adb0-431c-8f4e-b8351050aa98">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_12d5df73-80fe-4fa8-9ebb-7c6fa5521c96">CONTAINER</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_76b3288c-dd2b-4f8b-9676-a100515de5c5">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_40163bdb-f184-45f7-8481-417c37adc9bf">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a556d95d-9db9-49d1-b3b8-4ca32ef62ada">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1d5f038e-188c-40cf-b070-107362fc64dd">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_506d8b41-6b79-4d16-8825-147b6eba320f">User Selected Fiducial</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b13b2d6a-b272-4804-8a8d-af9ff3fe7b7d">112356</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e953938d-646a-489f-97dc-e347d824f4b6">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7d330244-8de7-4a97-917e-496f6adb19f4">UIDREF</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_43cffce4-f25a-4138-8740-229f6833e4a9">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9912c363-cdd9-4ddd-81ef-87dc7e0b926d">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_78171830-ea11-4cb5-92ce-4e07d7c94c9b">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ea675c0a-ba73-46c9-bd98-3312a43de04e">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e41a0662-c5d7-4164-ad7a-43bf0b576232">Waveform Acquired</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d579e3e5-9a62-4e0e-a4f4-c7cfdb7c2aa4">121143</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f5171aba-4ddb-4969-80ef-1b60f94367b8">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_59bd1c4f-6853-4758-9dcb-43f489b8d48f">WAVEFORM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b586d838-38f1-455c-b4e2-f5cc5bc2cb91">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4b1a49c3-d312-468a-aa79-407f187f7f3b">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8204da02-2c4d-45c3-90c7-13b6a3acf33f">D</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8328dc03-d67b-44c3-b5c4-a68ed38acb5d">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_447766d7-3269-4a78-a16d-5eb303eb211e">X-Ray Attenuator Model Data</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_88aa9d15-cd3d-422a-8222-b89758946456">128470</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e41648ac-ea76-4826-bc44-5ccc10724025">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b38c1f97-5261-4b16-a4a7-8194228d79bf">COMPOSITE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7d2e0a23-8027-47e1-a353-6d1b316f125f">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_75e85975-0cbe-4d15-9d35-d9c78222881d">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_514934ca-5441-468e-a690-c605e786f8e6">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c55e39fa-8bae-4b9d-be37-4fc8548312be">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1fe5b3cd-f0d5-41aa-a8af-9971f51faa4c">X-Ray Attenuator Model Data</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_69b2d8cd-01ab-4e2b-9498-6cce039cf5ee">128470</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b955040a-aaef-456c-9f07-d6af6d983254">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5e228c99-c56f-4724-8656-955d1a394c0d">IMAGE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a7d1dbf2-8868-4822-bfe6-88fec955624d">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8db327ae-e7bf-4e39-b524-c3fa7d9e66bb">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7280a2a6-49ef-48f7-a0a0-67e3f80d8ee0">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_70780506-3510-43df-98b9-b3634d700ecd">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_082b1c16-06fc-4ae0-9f92-dfd16e2438fe">X-Ray Attenuator Model Data</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_85128e1e-3394-48f5-94bb-3079ef268d2b">128470</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e0c5c180-a433-4d6e-b18f-62ead58ef645">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b03807a1-5140-41c8-a738-19fcc903b40c">UIDREF</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8f12ff8c-3b30-4c4d-9a88-189bd2f0ab02">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e8d78518-490e-48ad-9dd1-5aac88aa42e7">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d626bf8f-5843-4fb2-af7f-771f4ed0754d">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_73762a81-2c0e-43de-803a-75d60824e654">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_15daa7b6-4504-457a-b3d1-791c8e1297cb">X-Ray Radiation Dose Report</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8f43c868-2aff-4a01-b70a-cc97bc52952e">113701</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_48436268-7918-4063-bfe6-93f7529e4ded">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_93601210-9436-4b4d-bb05-5ef94e4b60fb">COMPOSITE</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2aa72c87-15f2-4c49-b5e4-5408012c21e6">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3677d47f-a964-4b1e-a9e4-f1ff306e00da">Y</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_37f7a46a-37d0-4752-98c9-e696720d4c86">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6cf87332-41a5-4cd3-88dc-ca6114464502">K</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                </tbody>
            </table>
            </section>
            <section label="E.3.5" status="3" xml:id="sect_E.3.5">
                <title>Clean Descriptors Option</title>

                <para xml:id="para_6e67e645-8738-43f2-a293-0eb8a64270e1">Even though many Attributes are defined in the DICOM Standard for specific purposes, such as to describe a Study or a Series, those that contain plain text over which an operator has control may contain unstructured information that includes identities.</para>
                <para xml:id="para_eb16943f-79ba-4765-bedf-94a66b6744ac">When this Option is specified in addition to the Basic Application Level Confidentiality Profile, any information that is embedded in text or string Attributes corresponding to the Attribute information specified to be removed by the Profile and any other Options specified shall also be removed, as described in <xref linkend="table_E.1-1" xrefstyle="select: label"/>.</para>
                <note>
                    <orderedlist numeration="arabic">
                        <listitem>
                            <para xml:id="para_d32ae72c-0b9c-482f-a70f-2d7a9e0c69aa">For example, an operator may include a person's name or a patient's demographics or physical characteristics in the Study Description (0008,1030), perhaps because their modality user interface does not provide other fields or because other systems do not display them. E.g., the description might contain "CT chest abdomen pelvis - 55F Dr. Smith".</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_d37786ae-b8c3-44ec-8c8a-df3ee2e8b832">One approach to cleaning such text strings without human intervention is to extract and retain only values known to be useful and safe and discard all others. For example, in the string "CT chest abdomen pelvis - 55F Dr. Smith" are found in Study Description (0008,1030), then it would be feasible to detect and retain "CT chest abdomen pelvis" and discard the remainder. In an international setting, this may require an extensive dictionary of words that are safe to retain, e.g., to detect "Buik" for abdomen in Dutch or "λεκάνη" for pelvis in Greek. Another possibility is to extract such information and attempt to code the information in other Attributes (if otherwise absent or empty) such as Anatomic Region Sequence (0008,2218). However, the possibility of string values being both identifying and descriptive in different uses needs to be considered, e.g., "Dr. Hand" or "M. Genou".</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_61eacf2c-0d20-4915-9664-8674488d6866">
                                <xref linkend="table_E.1-1" xrefstyle="select: label"/> calls out specific Attributes known to be at risk, but an implementer may want to consider any Attribute that could potential contain character data, though this Option does not require that this be done. For example, all SH, LO, ST, LT and UT Value Representations could perhaps be misused. Code strings, CS, are not generally at risk, but a check against known Defined Terms and Enumerated Values could be performed. Though extremely unusual, it is conceivable that even a DS or IS string could be misused, and a check could be made that only legal numeric characters were used. Any PN Attribute is obviously at risk. The OB VR is discussed in the Retain Safe Private Option.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_84d53a69-e582-465b-8d44-60fa7ce00621">This Option specifies what needs to be removed, not what needs to be retained. Depending on the application, it may be desirable to retain some information, such as technique description, but discard other information, such as diagnosis, for example because it may bias the interpretation in a clinical trial. For example, one approach is to remove all description and comment Attributes except Series Description (0008,103E), since this Attribute rarely contains identifying or diagnosis information yet is typically a reliable source of useful information about the acquisition technique populated automatically from modality device protocols, though it still could be cleaned as described in Note 2.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_6c5ab484-8705-4d7d-a628-ce6bf300e8b3">It should be recognized that if any descriptor contains information about a particularly unusual procedure or condition, then in conjunction with other demographic information it might reduce the number of possible individuals that could be the imaging subject. However, this is to some extent true also if the condition or other unusual physical features are obvious from visual examination of the images themselves. E.g., how many conjoined twins born in a particular month in Philadelphia might there be?</para>
                        </listitem>
                    </orderedlist>
                </note>
                <para xml:id="para_aa4daf86-3e83-4fb1-bb77-75ca192fa98b">The manner of cleaning shall be described in the Conformance Statement.</para>
            </section>
            <section label="E.3.6" status="3" xml:id="sect_E.3.6">
                <title>Retain Longitudinal Temporal Information Options</title>

                <para xml:id="para_e7eb7427-5fea-4b7b-a219-d4e9a0f8ec56">Dates and times are recognized as having a potential for leakage of identity because they constrain the number of possible individuals that could be the imaging subject, though only if there is access to other information about the individuals concerned to match it against.</para>
                <para xml:id="para_030cf9a3-f89e-4c57-b94a-842db3aecea1">However, there are applications that require dates and times to be present to able to fulfill the objective. This is particularly true in therapeutic clinical trials in which the objective is to measure change in an outcome measure over time. Further, it is often necessary to correlate information from images with information from other sources, such as clinical and laboratory data, and dates and times need to be consistent.</para>
                <para xml:id="para_8bfa03c7-fa72-4888-ad34-c8ded393c10b">Two mutually exclusive Options are specified to address these requirements:</para>
                <itemizedlist>
                    <listitem>
                        <para xml:id="para_714a3d71-cfae-43a6-9b0a-b80d12c4dd50">Retain Longitudinal Temporal Information With Full Dates Option</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_576d373f-bc21-4225-a5fd-45f2b31bed59">Retain Longitudinal Temporal Information With Modified Dates Option</para>
                    </listitem>
                </itemizedlist>
                <para xml:id="para_389c7767-f03f-4716-970d-72a2766aabfa">When the Retain Longitudinal Temporal Information With Full Dates Option is specified in addition to the Basic Application Level Confidentiality Profile, any dates and times present in the Attributes shall be retained, as described in <xref linkend="table_E.1-1" xrefstyle="select: label"/>. The Attribute Longitudinal Temporal Information Modified (0028,0303) shall be added to the Data Set with a Value of "UNMODIFIED".</para>
                <para xml:id="para_b71081d0-569f-4426-aa01-b0765ce1ab32">When the Retain Longitudinal Temporal Information With Modified Dates Option is specified in addition to the Basic Application Level Confidentiality Profile, any dates and times present in the Attributes listed in <xref linkend="table_E.1-1" xrefstyle="select: label"/> shall be modified. The modification of the dates and times shall be performed in a manner that:</para>
                <itemizedlist>
                    <listitem>
                        <para xml:id="para_04a9122d-b1f6-4f16-96e3-46b3f1ee6165">aggregates or transforms dates so as to reduce the possibility of matching for re-identification</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_82eae777-e9eb-4445-9b6c-bd47b153329c">preserves the gross longitudinal temporal relationships between images obtained on different dates to the extent necessary for the application</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_c4869466-f8bb-4da5-8a7c-dd59fbb7a974">preserves the fine temporal relationships between images and real-world events to the extent necessary for analysis of the images for the application</para>
                    </listitem>
                </itemizedlist>
                <para xml:id="para_eb42e924-3cfc-4d91-aa01-0f153b41b88c">The Attribute Longitudinal Temporal Information Modified (0028,0303) shall be added to the Data Set with a Value of "MODIFIED".</para>
                <note>
                    <orderedlist numeration="arabic">
                        <listitem>
                            <para xml:id="para_45e31969-dc33-493e-b413-36a407968cff">Aggregation of dates may be performed by various means such as setting all dates to the first day of the month, all months to the first month of the year, etc., depending on the precision required for the application.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_cee62190-61bc-47ba-bf0b-23e3aefc6f74">It is possible to modify all dates and times to dummy values by shifting them relative to an arbitrary event, and hence retain the precise longitudinal temporal relationships amongst a set of studies, when either de-identification of the entire set is performed at the same time, or some sort of mapping or database is kept to repeat this process on separate occasions. It may also be desirable to record the type of event and the temporal offset from that event, and Attributes are provided for that purpose; see Longitudinal Temporal Offset from Event (0012,0052) and Longitudinal Temporal Event Type (0012,0053) in the <olink targetdoc="PS3.3" targetptr="sect_C.7.2.3" xrefstyle="template:PS3.3 Section %n %t"/>.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_022291d8-0c4d-4725-b43f-a195028dbdcd">Transformation of dates and times should be considered together, in order to address studies that span midnight.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_9a0d80b4-2672-4fa3-871b-4b5668016946">Any transformation of times should be performed in such a manner as to not disrupt computations needed for analysis, such as comparison of start of injection time to the acquisition time for PET SUV, or extraction of time-intensity values from dynamic contrast enhanced studies.</para>
                        </listitem>
                    </orderedlist>
                </note>
                <para xml:id="para_cc45149e-ac5e-4b26-bb5f-b8af861cc54d">The manner of date modification shall be described in the Conformance Statement.</para>
            </section>
            <section label="E.3.7" status="3" xml:id="sect_E.3.7">
                <title>Retain Patient Characteristics Option</title>

                <para xml:id="para_62f67d27-cdfc-4f17-b513-bdb14da4fa7b">Physical characteristics of the patient documented in the Attributes, which are descriptive rather than identifying information per se, are recognized as having a potential for leakage of identity because they constrain the number of possible individuals that could be the imaging subject, though only if there is access to other information about the individuals concerned to match it against.</para>
                <note>
                    <para xml:id="para_35766f98-a51b-4a52-8f88-14a9c731bbf8">This is distinct from physical characteristics that can be derived from the Pixel Data, such as age or sex estimation from the appearance of the bones.</para>
                </note>
                <para xml:id="para_9b41813f-1d52-43b1-a569-c9c98c7f99d5">However, there are applications that require such physical characteristics in order to perform the computations necessary to analyze the images to fulfill the objective. One such class of applications is those that are related to metabolic measures, such as computation of PET Standard Uptake Values (SUV) or DEXA or MRI measures of body composition, which are based on body weight, body surface area or lean body mass.</para>
                <para xml:id="para_2c0a8a67-3b2e-4aad-9153-8491ced6d071">When this Option is specified in addition to the Basic Application Level Confidentiality Profile, information about age, sex, height and weight and other characteristics present in the Attributes shall be retained, as described in <xref linkend="table_E.1-1" xrefstyle="select: label"/>.</para>
                <para xml:id="para_324c4b43-2572-4a19-917c-cab57003b769">The manner of cleaning of retained Attributes shall be described in the Conformance Statement.</para>
            </section>
            <section label="E.3.8" status="3" xml:id="sect_E.3.8">
                <title>Retain Device Identity Option</title>

                <para xml:id="para_6e63562c-5fa2-4469-806c-03b08f59d3e2">Information about the identity of the device that was used to perform the acquisition is recognized as having a potential for leakage of identity because it may constrain the number of possible individuals that could be the imaging subject, though only if there is access to other information about the individuals concerned to match it against.</para>
                <para xml:id="para_e78b6105-d25c-4cf8-a9ea-cf43098a6139">However, there are applications that require such device information to perform the analysis or interpretation. The type of correction for spatial or other inhomogeneity may require knowledge of the specific device serial number. Confirmation that specific devices that have been previously qualified (e.g., with phantoms) may be required. Further, there may be a need to maintain a record of the device used for regulatory or registry purposes, yet the acquisition site may not maintain an adequate electronic audit trail.</para>
                <para xml:id="para_b25bc4b3-fc71-4f14-b464-79b8a6591b62">When this Option is specified in addition to the Basic Application Level Confidentiality Profile, information about the identity of the device in the Attributes shall be retained, as described in <xref linkend="table_E.1-1" xrefstyle="select: label"/>.</para>
                <para xml:id="para_37710d62-ea25-47be-b824-f4ba645f70dd">For some retained values, such as Application Entity Titles, if these are to be retained they are specifed to be Cleaned, rather than just Kept, since they may contain embedded institution or person identification information that is not intended to be disclosed.</para>
                <note>
                    <para xml:id="para_25d09c7c-be60-4c75-b83f-8efff9a11187">The Source Application Entity Title (0002,0016), Sending Application Entity Title (0002,0017), and Receiving Application Entity Title (0002,0018) are not included in the list of Attributes to be removed or retained, since they are part of the File Meta Information (see <olink targetdoc="PS3.10" targetptr="PS3.10" xrefstyle="select: labelnumber"/>), which is entirely replaced whenever a file is stored or modified during de-identification. See <xref linkend="sect_E.1.1" xrefstyle="select: label"/>.</para>
                </note>
            </section>
            <section label="E.3.9" status="3" xml:id="sect_E.3.9">
                <title>Retain UIDs Option</title>

                <para xml:id="para_c95beebc-f832-4187-8ef9-37bc061fa1c9">Though individuals do not have unique identifiers themselves, studies, series, instances and other entities in the DICOM model are assigned globally unique UIDs. Whilst these UIDs cannot be mapped directly to an individual out of context, given access to the original images, or to a database of the original images containing the UIDs, it would be possible to recover the individual's identity.</para>
                <para xml:id="para_36d80c44-a53c-40e3-aa86-773f5f3a6ddc">However, there are applications that require the ability to maintain an audit trail back to the original images and though there are other mechanisms they may not scale well or be reliably implemented. This Option is provided for use when it is judged that the risk of gaining access to the original information via the UIDs is small relative to the benefit of retaining them.</para>
                <para xml:id="para_d44e046d-c417-4283-9556-695a778ca4f5">When this Option is specified in addition to an Application Level Confidentiality Profile, UIDs shall be retained, as described in <xref linkend="table_E.1-1" xrefstyle="select: label"/>.</para>
                <note>
                    <orderedlist numeration="arabic">
                        <listitem>
                            <para xml:id="para_66b78f7c-ac05-4a50-885c-2aa2a0b02943">A UID of a DICOM entity is not the same as a unique identifier of an individual, such as would be proscribed by some privacy regulations.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_d035af0a-6d15-41d8-baff-ef125f173148">UIDs are generated using a hierarchical scheme of "roots", which may be traceable by a knowledgeable person back to the original assignee of the root, typically the device manufacturer, but sometimes the organization using the device.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_bfceb09e-a261-4123-913e-750dcff0d238">When evaluating the risk of matching UIDs with the original images or PACS database, one should consider that even if the UIDs are changed, the pixel data itself presents a similar risk. Specifically, the pixel data of the de-identified image can be matched against the pixel data of the original image. Such matching can be greatly accelerated by comparing pre-computed hash values of the pixel data. Removal of burned-in identification may change the pixel data but then matching against a sub-region of the pixel data is almost certainly possible (e.g., the central region of an image). Even addition of noise to an image is not sufficient to prevent re-identification since statistical matching techniques can be used. Ultimately, if any useable pixel data is retained during de-identification, then re-identification is nearly always possible if one has access to the original images. Ergo, replacement of UIDs
                                should not give rise to a false confidence that the images have been more thoroughly de-identified than if the UIDs are retained.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_f5246274-87df-4f8a-9dd3-f266ebc03971">Regardless of this Option, implementers should take care not to remove UIDs that are structural and defined by the Standard as opposed to those that are instance-related. E.g., one would never remove or replace the SOP Class UID for de-identification purposes.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_c1e98f23-4759-473f-9d65-c6543dca708e">The Implementation Class UID (0002,0012) is not included in the list of UID Attributes to be retained, since it is part of the File Meta Information (see <olink targetdoc="PS3.10" targetptr="PS3.10" xrefstyle="select: labelnumber"/>), which is entirely replaced whenever a file is stored or modified during de-identification. See <xref linkend="sect_E.1.1" xrefstyle="select: label"/>.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_6a425e0d-9e2d-462e-924f-845f63c2c203">UIDs may have been generated using a date/time stamp mechanism to assist in uniqueness generation.
                                Hence if the original UIDs are not replaced, they may assist identity recovery.
                                That said, the presence of an apparent date/time stamp in a UID does not indicate that it is an original UID, since replacement UIDs may contain new date/time stamps related to when the instance was de-identified.
                                Also, UUIDs may be time-based rather than name-based or random-number-based,
                                so use of the <olink targetdoc="PS3.5" targetptr="sect_B.2" xrefstyle="template:PS3.5 Section %n %t"/> mechanism does not necessarily avoid this issue.</para>
                        </listitem>
                    </orderedlist>
                </note>
            </section>
            <section label="E.3.10" status="3" xml:id="sect_E.3.10">
                <title>Retain Safe Private Option</title>

                <para xml:id="para_1d6b7025-554e-40c2-bafa-39c2daed3955">By definition, Private Attributes contain proprietary information, in many cases the nature of which is known only to the vendor and not publicly documented.</para>
                <para xml:id="para_fec0be3d-44f3-4c55-9471-1fcef67db8ae">However, some Private Attributes may be necessary for the desired application. For example, specific technique information such as CT helical span pitch, or pixel value transformation, such as PET SUV rescale factors, may only be available in Private Attributes since the information is either not defined in Standard Attributes, or was added to the DICOM Standard after the acquisition device was manufactured.</para>
                <para xml:id="para_bb1aaf5b-ab3d-4b05-8226-c7282cf98dc9">When this Option is specified in addition to the Basic Application Level Confidentiality Profile, Private Attributes that are known by the de-identifier to be safe from identity leakage shall be retained, together with the Private Creator IDs that are required to fully define the retained Private Attributes; all other Private Attributes shall be removed or processed in the element-specific manner recommended by Deidentification Action (0008,0307), if present within Private Data Element Characteristics Sequence (0008,0300) (see <olink targetdoc="PS3.3" targetptr="sect_C.12.1" xrefstyle="template:PS3.3 Section %n"/>).</para>
                <para xml:id="para_ae514a31-161a-421e-8d38-e06c466773af">Whether or not an Attribute is known to be safe may be determined by:</para>
                <itemizedlist>
                    <listitem>
                        <para xml:id="para_8621c63f-c569-423f-89d4-cc51d4c116cf">its presence in a block of Private Data Elements with a Value of "SAFE" in Block Identifying Information Status (0008,0303) or individually listed in Nonidentifying Private Elements (gggg,0004) (within Private Data Element Characteristics Sequence (0008,0300); see <olink targetdoc="PS3.3" targetptr="sect_C.12.1" xrefstyle="template:PS3.3 Section %n"/>)</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_87201ae4-9353-4f34-80ab-075d72a24cbf">its presence in <xref linkend="table_E.3.10-1" xrefstyle="select: label title"/>
                        </para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_0a191532-1817-4b6c-a5e0-c475e45b002c">documentation in the Conformance Statement</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_8a298f8e-99a5-4fbf-b728-2eb2b6b1bb09">some other means.</para>
                    </listitem>
                </itemizedlist>
                <para xml:id="para_0c838fa8-6930-4559-a492-67c204358848">When this Option is not specified, all Private Attributes shall be removed, as described in <xref linkend="table_E.1-1" xrefstyle="select: label"/>.</para>
                <para xml:id="para_d9eb6fdb-b5c9-44d8-91f9-e0fe71983689">When an entire Sequence (SQ VR) Private Attribute is not known to always only contain safe content,
                    whether that content consists of Standard Attributes or Private Attributes or a combination of both,
                    then when the Retain Safe Private Option is used,
                    any such Sequence Attribute shall be parsed in its entirety and each of the nested Attributes handled on its own merits,
                    rather than removing the Sequence in its entirety without further consideration.
                    Reviewing the content may be a sensible practice to apply even to nominally known safe Private Sequence Attributes.</para>
                <note>
                    <orderedlist>
                        <listitem>
                            <para xml:id="para_8348851c-c236-4e1d-820b-f2d693eb0857">A sample list of Private Attributes thought to be safe is provided here. Vendors do not guarantee them to be safe, and do not commit to sending them in any particular software version (including future products).</para>
                            <table frame="box" label="E.3.10-1" rules="all" xml:id="table_E.3.10-1">
                                <caption>Safe Private Attributes</caption>
                                <thead>
                                    <tr valign="top">
                                        <th align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2c9eedc6-e981-424a-aaba-02338b7bd3a6">
                                                <emphasis role="bold">Data Element</emphasis>
                                            </para>
                                        </th>
                                        <th align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5ac89912-a4d0-467e-a5f6-79d86a4e4902">
                                                <emphasis role="bold">Private Creator</emphasis>
                                            </para>
                                        </th>
                                        <th align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_da5d42a9-8e1f-44f4-a6dd-f2eaa98a401b">
                                                <emphasis role="bold">VR</emphasis>
                                            </para>
                                        </th>
                                        <th align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_389182b9-579c-485e-9475-c8c57f0473f7">
                                                <emphasis role="bold">VM</emphasis>
                                            </para>
                                        </th>
                                        <th align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d4ede75b-b116-4bec-b6cb-7b3a548399c7">
                                                <emphasis role="bold">Meaning</emphasis>
                                            </para>
                                        </th>
                                    </tr>

                                </thead>
                                <tbody>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_537485c9-1a82-41df-b741-d97b9c43ef3f">(7053,xx00)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_28e7f6a9-847d-41ed-9bff-56107db816c1">Philips PET Private Group</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6280d14a-b7aa-4e3d-b0b2-09cb74644d15">DS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b5cc5e21-d534-42b5-ae19-3783745d0e98">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_38ce5923-8365-4d77-9c3b-63d87fad9c2a">SUV Factor - Multiplying Stored Pixel Values by Rescale Slope then this factor results in SUVbw in g/l</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cf0b21fc-9fc2-4db2-bb3e-e6acb7293017">(7053,xx09)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_9f2b1fb1-e0bc-4fff-bf8c-09898f415a1e">Philips PET Private Group</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8bf74992-7976-41dd-8319-14d7238fbab2">DS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_03ca18e3-ab6d-4372-8581-7d7f1a2e4de2">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_62e603f2-6005-4e70-84ef-4a5cc0c9376e">Activity Concentration Factor - Multiplying Stored Pixel Values by Rescale Slope then this factor results in MBq/ml.</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_57d49418-60c7-4c77-b3d0-791f3b1d74a8">(00E1,xx21)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_09c7a21f-5216-4da8-9a27-65b316031512">ELSCINT1</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ffb8c5ad-2c51-4f8e-940a-26c551e9bfb7">DS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d64d5d07-0a1f-479c-bf0a-7d2d2f23d3d9">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_541f9e8c-9f2f-4b0d-aba3-d9b3691ddaf5">DLP</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_56039e61-4536-4335-b253-1d9dfbd46bab">(00E1,xx50)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_88f69dd8-3eab-4889-aad5-c53d27e79488">ELSCINT1</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4dfe3344-9784-4d17-93a6-7b9223befcd0">DS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3ef81964-dbba-4e4b-83e8-c65b909c94e2">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_813263c3-953d-4cca-aa7c-ebad18aaa2b2">Acquisition Duration</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_00079aa2-36e6-4d90-a874-38c53bd56673">(01E1,xx26)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_be0581ae-f514-4bc1-a23f-ce37570d8f33">ELSCINT1</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_37617913-5d19-45fb-a6e8-864475b50877">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_eb18e6ad-c3d2-43de-b5ee-331a01704b0a">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_009030a5-173b-40a0-a613-da9b7e8e0cc8">Phantom Type</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_07e0cbc0-fe1f-41e2-88a7-522da4024ca0">(01F1,xx01)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6755106d-85eb-4e02-afed-884f35330757">ELSCINT1</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1f3d8aa2-2aea-4d20-a048-17fcd610ab48">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f23be189-04ce-49ee-b7ad-66bb29c5ce71">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6f4fa660-df03-42aa-8318-0f644148c55b">Acquisition Type</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_099d070c-5d1f-4219-89ff-a697d5c1997a">(01F1,xx07)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_0c9d105a-a10f-41fe-808e-11c484f4c5f9">ELSCINT1</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7439fcdc-f5b4-4a22-a0a8-c5910bfa95f8">DS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_417671b0-1a2f-42df-b819-9be8e85a607e">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_cf0cffc3-2ba2-439e-9bf4-63e3520b9a7a">Table Velocity</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0be20e73-dffa-4153-a695-e5d351d3a138">(01F1,xx26)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_01d892c0-f4cf-4a1b-b1a0-d25fab1f50e9">ELSCINT1</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_77557e7c-7534-4a9f-af46-b3b695393d8e">DS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1935bdd3-22b2-4d75-a40d-913461f55431">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7b703afa-45c4-4edc-90b6-7e54d177c3a2">Pitch</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_15806809-d871-4779-aebc-b1bab5b23985">(01F1,xx27)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_84084f38-7e5d-44fd-acea-bbe585b803dc">ELSCINT1</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_913481fe-e73f-46db-85c7-fc68a9c9dfcc">DS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0967f2ea-96d2-48f1-a15b-8bfb829a291f">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c932801d-89f9-4012-b0fe-81768c726b6f">Rotation Time</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_46665174-950e-41ea-9cba-ca1b324abdae">(0019,xx23)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e63717b9-7809-4f2b-9c6a-593e372e96f0">GEMS_ACQU_01</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_22a3fe7b-d064-4be9-a75c-9ee0dd214174">DS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_29197f15-5e20-4c5b-9020-bbb1a253a1dd">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_24354a36-2bc9-47a7-ad1c-75ab5d0edaca">Table Speed [mm/rotation]</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_be9e6f4d-a93a-4df5-a84c-35c1727dd119">(0019,xx24)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_9d25858a-3fb6-4468-bd16-483de33f4982">GEMS_ACQU_01</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ad34a5f8-af4d-416f-9aef-fd62b466113c">DS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7b0af9e9-a8f9-4f86-98cd-5059e6f1ed38">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_490ba564-9a8d-444e-9040-f9f40ceb35cb">Mid Scan Time [sec]</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_80f38c15-a87a-4e59-9358-b8028adc8ac7">(0019,xx27)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_80af2c93-1207-4b7f-b464-7b63caa285a3">GEMS_ACQU_01</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8c9a83de-fea7-4cc3-8d76-695430aeab80">DS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_13a91a6b-2f97-4aeb-9a73-8f5e4a8e6f0c">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_cee57515-5b01-4b33-80a7-d433a7e0953d">Rotation Speed (Gantry Period)</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b4edf747-e8c4-499c-b2c5-937813650db0">(0019,xx9E)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_79d235b9-7aad-412d-940e-7f4d44602ef7">GEMS_ACQU_01</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_73caabe5-6ef5-411e-beee-c49840101df0">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_71778560-e1b3-42cd-a254-bcde1b3ebab5">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2b650d97-ad50-47a9-ac05-84665ee021de">Internal Pulse Sequence Name</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0bc09110-3ea5-47eb-8195-8337fbe131c2">(0043,xx27)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a0a14143-d3aa-4e41-960f-7190b5dc6238">GEMS_PARM_01</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_18d46c3d-601c-490b-ba86-a5f52280671c">SH</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e77e8e06-51a1-4ea7-91a3-6bd7a4992167">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_5f909ef9-3c16-4b6f-a1bb-5f57e53d63d5">Scan Pitch Ratio in the form "n.nnn:1"</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ea2796f7-cfca-4bf8-8f73-3132453108da">(0045,xx01)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3faf1c75-3a3c-4dfc-8d7f-e7799149540a">GEMS_HELIOS_01</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_685e029f-bed8-4be8-a204-8e255b39c2b7">SS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_aa15aca5-b450-416c-811b-7b6af63bedc4">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1c22638e-154a-489b-ac3e-085f482630d2">Number of Macro Rows in Detector</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5d582f8c-b33c-463c-9de9-89f32fdeeba2">(0045,xx02)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2836f896-47da-4668-90fd-462deb00c725">GEMS_HELIOS_01</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e5016699-ed3b-41ac-bcab-b3e6221cb4eb">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8c8d7dd6-9a0a-476d-ba80-33d7cd4807ef">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_295a62f0-99da-4473-a900-1a55a7cd2763">Macro width at ISO Center</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_148196c4-ceae-4987-bbdc-bbced76a492d">(0903,xx10)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_19783578-71d9-43e1-9e16-af3254f3aaac">GEIIS PACS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2e88e34e-9253-48c9-b38e-7347d701a254">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_039d1bd6-43bb-4a4b-a256-e03a33affa21">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7dbca276-b043-4e10-93b3-5e4285c287ed">Reject Image Flag</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_85970c51-783f-48ba-8b59-4408d30dd156">(0903,xx11)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_9cd6f4cd-3bcb-4995-9116-3cf1e15ebe76">GEIIS PACS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_09ec66e8-bf32-4e9a-a09e-a084941522c6">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e59445f2-c39e-40d2-8824-12be918e33de">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_5c70b5df-60a9-43b1-86c0-f55df208f5aa">Significant Flag</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_45dab11b-cfb4-41f1-815f-4ffb8dc135a8">(0903,xx12)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3b928979-f306-47f4-b14e-5fcfcbaf3cb1">GEIIS PACS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d8331882-83c1-4175-b29a-59109b533849">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2ace671b-fa91-4667-974f-06e56cd0871f">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6f3680ce-0f50-4d6e-a8a7-9b3197dc8e5a">Confidential Flag</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9a89707d-dd9b-4917-afff-be4a744a750d">(2001,xx01)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2e7e5cd2-8c5b-40ed-9153-b35da6cd58b1">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f76c9a64-005e-4518-9c00-81a5792da41e">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c2e418be-b327-43af-aefc-7c5da86ccf1c">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_57de69db-68db-4e0d-af26-e8b1fcbb9360">MR Image Chemical Shift</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a436fd94-7144-4c0e-8599-6b467939fa71">(2001,xx02)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a93d90b9-c579-41a0-b79f-78c2bad6f827">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_85fbc145-f12d-429d-883f-8e0fcaecb700">IS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5937c3c2-0cf3-40f5-b1a0-77fccfe81ad9">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e273149f-7f67-4866-a6ca-6f6499236379">MR Image Chemical Shift Number</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c50eaef7-25f1-4df8-9872-2a7033bad861">(2001,xx03)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6afcfc46-3763-4b22-9317-609b1bb28ae9">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a8f8fb23-9cf9-40f7-9ab6-61ac9689073e">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9bcc7f2e-d9dd-4ed8-9b66-c046c725c3d9">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_12d4f2f5-cfe3-4f02-b219-c0e99b03af21">MR Image Diffusion B-Factor</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_767e28d0-31ac-4518-8fd0-f588756f378d">(2001,xx04)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b8a816a5-8ed4-483b-ae38-28e37c608be8">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_444c8c49-783a-4355-8f8f-1a3a815b69a4">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ecdbed83-89d0-4110-ba2b-3f22b0fc12a2">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a924b127-5962-416a-b415-9e3858c568ff">MR Image Diffusion Direction</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2f0f69a9-0d81-45f6-a65e-13614db9dec1">(2001,xx05)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e6ad215b-c8dd-4531-88de-eb0a01a58d90">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4bd6ca12-e9b3-4230-b337-2979745131f9">SS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0e82be6a-f9eb-4de9-9060-1e16c52f9662">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_5f4d13c0-4057-445c-b2b2-3e2a598838c6">Graphic Annotation Parent ID</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_64b57082-10d0-4af9-8b09-dcabff8de8c1">(2001,xx06)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_dc66d7c7-29db-4d91-a194-706d195dc7c1">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_87e90632-0e5e-4eb1-8fe4-283e0e14cc6e">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f3eeab5c-a53b-49d9-b9d1-ee29ee13f87a">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_bc35b123-414a-4fec-9ed4-0032983e716d">MR Image Enhanced</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3e8a8ae9-2eae-4fa5-8262-1dcdcc0a1a3a">(2001,xx07)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3856cdc1-12ae-4e5f-a1fd-2c1540c98014">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a6fc5b34-ff2c-404e-b881-67dc953a8a1b">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e958a846-ccba-48b1-a843-9394d246b16c">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_77e3b75c-4166-4e2e-85d0-66795af4ffa6">MR Image Type Edes</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_50583ea6-9270-49a5-82c8-128dd36dca23">(2001,xx08)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_9870aaaf-025e-48a8-8400-b2b16fba41c3">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cafc225d-85bf-49da-879f-822c54830b19">IS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b63e3fc9-d2a2-4cb9-aa68-dcd1a252e704">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_49494767-17b6-4dcf-868d-261a283e5ef4">MR Image Phase Number</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1fa1d24c-f4d5-48ae-b715-4c7ac86c3944">(2001,xx09)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_20dd93dc-c1f8-4818-8379-cba4957c8109">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3bd546d3-1ed1-4c4a-bdfb-c94f4c771eb3">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0c6c85f8-c445-4d6f-945b-ac0ca3638a9b">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_017bcdca-9d48-402f-aa1b-455683d2cfb7">MR Image Prepulse Delay</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e98b0b60-7449-4d00-bc7c-5645f76a2fdc">(2001,xx0a)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6b348e61-b0ea-4b19-bb3c-102bd72b5566">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_18175fae-0e69-469b-9004-866861e7eeee">IS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ae78c96f-30d3-4907-96bc-3cfa94d1429c">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_bdf3082d-9085-42ad-a8f0-18e349fd63f4">Image Plane Number</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6cbbd585-2d9f-4987-b172-daaa37943e0d">(2001,xx0b)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_66994d61-2cdb-417c-8957-ff5239b7012b">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cbd37773-0d64-48a3-b35b-e63d5ea639e2">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2cf1b1b5-a581-4d5b-a28f-c8a931ebe175">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c1dc4b0c-ca04-4276-baa9-40fd79ef5eaf">Image Plane Orientation</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4aa25c2a-0d7c-4601-8edd-81f020eb1218">(2001,xx0c)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d0cb44e7-595f-4582-a398-b4016b094482">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0f817bfe-584b-4bf4-9484-796e1f549072">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9c94d3fc-4652-407b-a346-8070e4b646e6">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d29789cc-8653-4689-9983-e4e604f0a72c">MR Series Arrhythmia Rejection</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_201399ac-d729-40c4-851d-eafa1c3cc12c">(2001,xx0e)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d627121b-8a1e-4607-b35b-ec4ae7720f8f">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_65b1275b-7a22-4999-a535-936094a6fdef">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2c68a987-f1ea-4902-bf21-cad8a23b0951">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_04d47fd6-8582-4b1f-854f-7975fee95d9f">MR Series Cardiac Cycled</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_32120770-cc9d-4428-b9cb-95fc10d4f022">(2001,xx0f)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ab1f2aa5-af88-441e-9c37-dffe9c3a728e">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9d26ed87-e615-46d9-aa7e-fe8ac1642f2a">SS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f962212d-0e83-4f9f-857c-55e5c11b5fea">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4a76af0a-bec8-42f1-bd4a-29888efafde6">MR Series Cardiac Gate Width</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_acbe86e8-6d60-4cda-96d6-aa1d5b4f56b5">(2001,xx10)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a2a90b1b-083f-4629-8c73-94b73862356b">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c1485bc8-71be-4cfb-a703-c0e837520206">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4051a320-051b-40a3-84a4-e84f1acab033">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_97d763ff-2150-4882-8971-d0fb5818f0a0">MR Series Cardiac Sync</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_44ffcd52-288b-45de-8159-2fbc155beadf">(2001,xx11)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_14a71f5f-1791-405c-955d-3f9a18afc1d1">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_995f516c-037b-4c4d-8a50-5e98a4ee2b6a">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_41fbaa54-7e93-4565-a5f7-5cc298c788c2">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1bcc9085-043d-4700-b551-c1587b6efcfc">MR Series Diffusion Echo Time</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_200042d1-01ad-4a9d-9175-ac94a51be42c">(2001,xx12)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_fc532fed-1998-400f-a957-36d01a14c66e">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_19fc477b-1422-4db7-a358-57ab1573b458">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0ba57a26-869b-4487-89f1-135dca6eb681">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_9c1de2c4-40b9-40fd-ae12-f5d4c6c64396">MR Series Dynamic Series</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d6876c00-ebbf-4134-894d-371073ae33a7">(2001,xx13)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1c547f8a-a086-4c38-8d45-2dfa85a39d16">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b8cc9890-f3e3-4346-9b15-526fa9c98141">SL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_32b503d9-e23a-403d-a004-456475260896">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_5eea7ee6-daa5-4513-b2b2-b905bf593417">MR Series Epi Factor</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ba52d787-bc04-4dc3-a0da-5fc9959a745c">(2001,xx14)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_21cd4db2-fba7-4677-9f25-85e2cdc53557">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7776cc73-47d5-46d0-83f4-bb4c5208d283">SL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_78a301b1-39da-4872-bde2-0150d7b7f5e4">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c04b8013-e19f-4135-90ab-d8792f0d46da">MR Series Nr Of Echoes</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_db2f0e29-1222-4593-8232-5483caef85d8">(2001,xx15)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3bd48ddc-4173-4f2b-b311-c740b47900c4">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_59854580-2d8a-4513-9351-4db38db6f315">SS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ecec1a63-faf9-48f4-9f06-126b5b30fe6c">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_655faf11-ebe0-44ce-9aa4-09f3fc5bd563">MR Series Nr Of Locations</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_950dd096-047d-4858-a9b9-25e2325d0506">(2001,xx16)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_63132a3f-4134-4a46-b323-61c3514e8e4b">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c091a3a8-a9ce-4e41-b2b4-7635d78aee66">SS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3188c5de-d7ba-415d-b10c-7907c5594c98">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e994abb3-7be5-4dd1-a67f-83749f950d3f">MR Series Nr Of Phase Contrast Directions</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_344247bb-6329-42a4-a88e-d255baaf3a8e">(2001,xx17)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8a189272-3e0e-499b-96eb-056ab6aa07f4">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cdb682bb-80a7-4147-bfcc-26c78b2e5ef6">SL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cb6ee705-ec96-4c03-884c-80ee3b864b92">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b3b163b5-683f-44fb-b74b-246085be42ed">MR Series Nr Of Phases</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_250d8705-9786-4b0b-bfca-6fc2654105db">(2001,xx18)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_697d0815-cb48-4b3d-a302-efea5215431a">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_246e6182-bce8-4448-b02a-e9fd1210aeab">SL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_de3d2901-04f3-4518-a1ba-57cf82b499ce">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3fd8319c-a1f9-4b18-bbb6-4ee90449dbba">MR Series Nr Of Slices</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_872839e7-cc3f-4111-8a91-a10f31650bb4">(2001,xx19)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a0a7ae76-9931-4d48-a6af-952f30a6581e">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_21b987ef-afcc-4aa1-b25f-0198aacd908e">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3edd8d12-a8da-44c3-ac0b-12e523d347e2">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3b004d3d-638f-4348-acb7-73b4d739f307">MR Series Partial Matrix Scanned</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_20fdb8b2-a438-4c53-a34a-db18187ac409">(2001,xx1a)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4159bc47-151d-409c-a79f-31656b54a71c">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2069a424-97ce-41d5-b3a7-e90c9bd7757b">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_649ddbad-f86a-4903-8a28-ab5131f804ee">3</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6b3728bd-9f5d-4a50-baf9-b8008a7b9a05">MR Series Pc Velocity</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6ffa8ec8-d3ee-4af8-a02a-e13b670cc524">(2001,xx1b)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_35bfa780-c401-4f73-9472-820fda0a54ce">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d51effbe-1290-4614-a2c1-4fc3fc1eba33">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_45dea875-a0bf-4e9d-9aa2-953fa2b4bcc0">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_fcd089fe-ef89-4a03-9d50-f750124bdf19">MR Series Prepulse Delay</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5a2a6e49-753c-459a-af31-0171e19b0aab">(2001,xx1c)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a2b46914-b708-46ac-b4e6-47df39514c0c">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0f6a9d3b-0ce1-4706-84a8-6abde5c20e66">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_eadc67da-96af-4bb5-b3f1-5c4defd45989">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_39dc7f83-a2a7-487d-b2e9-cb26b7ad517e">MR Series Prepulse Type</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1e6b15ff-9498-4435-a1ea-f72c3c7a9d35">(2001,xx1d)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_9dcaff9d-fe87-43fd-ab4c-d88f45384f96">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_310ce1a4-2c9d-40f9-bc4a-4551508257f9">IS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8c59c15d-7c24-48b7-9885-821a9a9aabe6">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_14b7c235-f17b-40d6-9b93-f0df9ffbf9a3">MR Series Reconstruction Number</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_94c8aa95-76e6-4739-a0ee-5438a9f7e734">(2001,xx1e)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6530a3c4-8319-408a-af5c-75f96465590f">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ce42b83d-f0b0-4005-afd7-54ff8363d380">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c82f9fa2-03a2-4c7f-902e-8351539e7d74">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_11ee02fe-5063-43b7-8446-e86d990719d6">MR Series Reformat Accuracy</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_03d137d2-e17e-41ae-bcd6-50e1b4785164">(2001,xx1f)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a5ad45bc-43b1-44a9-8979-1f830302fc68">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cb7dbf95-5e48-4903-8853-db4e4a0faa9f">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0dc59622-d249-4572-ac16-fd7e55dca514">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e7c60927-6863-442b-a4dd-82b8876237b1">MR Series Respiration Sync</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a59d141f-b0f2-4a21-9136-6d8ce34c619f">(2001,xx21)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_df2fc86f-b72d-4f0f-8ee0-1abe0879e9da">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1785d85a-9814-420d-8ae6-b900037aa7a3">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_20057004-a7f9-468e-baad-f57a58a31185">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4162258b-0801-425b-a815-bc84cf685d9b">MR Series Sel Part Inversion Recovery</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ecd74ac2-f920-4c07-bf60-f6f445ff66ef">(2001,xx22)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c64bd113-98e1-41e3-bfcd-b0dd74613f59">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0ef9b66b-b880-49c4-9caa-a67be26cf68f">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6c319c51-1d4a-41f1-971d-47923373464b">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_086f7ece-4449-4726-9d79-9f7961c297b4">MR Series Water Fat Shift</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d988474f-18a5-4e41-9e63-a46d372718a1">(2001,xx23)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_434be86d-7220-4803-a2ce-73569ba8ca3d">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3a5c0e06-8a1a-4305-853d-b70f3ea05202">DS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ff9cf86d-af00-4fee-854e-794da4a3e352">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1bf7adf4-e669-4ec0-b017-3475e74ed255">MR Series Flip Angle</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7258e003-4d5c-464c-a833-e68653d0a77a">(2001,xx24)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7cd5746e-8fc7-42e4-9317-2080864a6a75">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_35e17d17-fbe9-4c8d-8ff7-02e1f336834a">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6e31d80f-bd40-4f2c-860d-5b6f6349a33c">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_be5b98e2-bf44-482c-a4a5-34324a2d0e54">MR Series Is Interactive</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9d95c283-ca25-4736-8aa5-27c1d3a58759">(2001,xx25)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3fb4e76e-16bd-4ba7-9be6-7348feb746f8">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_850e77fc-59d0-4e5b-ae08-2863809f7e6a">SH</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ed3fd0d5-38f8-4cba-8753-9dde6e063499">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2aeaf9db-fadc-46a2-ac6a-11b849213dce">MR Series Echo Time Display</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c084a51e-9cac-4f13-afd1-a20e060d5039">(2001,xx26)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4a864bae-6b92-4465-b0e1-82bbb7d1a215">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_faf72bc7-0b63-4e0f-84a5-007f1b727e17">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f5d07d41-6187-49e7-95eb-8f5378dac4a7">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7bd1685b-1954-4880-9804-a6dffef6ce4d">Presentation State Subtraction Active</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_03467fe4-3931-4220-a1ba-438edadcedc8">(2001,xx27)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_662415b3-77f3-456f-952f-9f54bd298795">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b8c71c3b-e423-42f3-9843-e43d2c3f3c25">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8e76bb29-9fea-43e6-8356-187df4c51fa0">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_aa0bff9b-2933-404a-8f98-df217a6b0175">Edge Enhancement Kernel Size</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_fec1fd2b-6a4a-46e3-ba1a-46dc2a6d07ec">(2001,xx28)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_42690a6d-d422-4a01-8724-a80eaa073fd5">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0d35eaca-fc3f-4ae1-a8c2-4922011f7709">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5439a16b-35ed-4746-81eb-c1f2619672ef">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_083c36fc-f2fa-406b-a7fc-af61bfa15909">Edge Enhancement Gain Factor Sub</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_427b019f-83ee-4647-987d-f22727e4581f">(2001,xx29)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ee4955a0-6ec4-4c09-b90b-18bf90041646">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7868999b-5268-4dce-ba11-87e564c3e3f1">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5c7c1450-7f5a-49b2-bcf4-c5ea0110f738">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a8df75a0-59ad-41e0-8021-4d6025e1b0b9">Edge Enhancement Gain Factor</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d5a2185e-b3cd-4ef4-a7ee-55592c9db307">(2001,xx2a)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_31184990-cf82-478e-93ae-4539ceb298e2">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2b62f08c-fcb0-435b-93d3-d8e08690c56f">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e5a98c33-6490-41eb-9e67-1565f7dbff72">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6ce3c44f-a923-4ffb-b899-ba0d73befd7a">Edge Enhancement Taste Adapt Sub</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ab58cb1a-b305-4d50-a905-800e9c0475db">(2001,xx2b)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_cfdeaf6b-d65e-4875-a5c7-c725f6b5c7b8">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_af415aef-1122-4fa4-90eb-137de7dc7bcf">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7b2be81d-088b-4be8-b80e-b5d4d782e9a7">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_924a202f-9361-488f-bd2c-553e955fe171">Edge Enhancement Taste Adapt</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_af624e07-f28a-4874-bb7d-bbeb4bc2bde5">(2001,xx2c)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f2b64da1-191c-4878-a380-4274fe1e31ef">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_762747b3-df0e-41f1-b4cb-c6c9b3670f5e">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1d132453-27d0-4295-84fa-48f6f99de48f">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4009c46a-651e-4a24-ad86-fd0bfe13dbf2">Harmonization Factor</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_13e29ece-9e91-45c6-af72-19f4f8066a16">(2001,xx2d)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_351a25d5-f09d-4af6-8ddd-8ec1871a54bc">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_404c81b3-ca6b-451c-bcf8-3b625ec9b5c5">SS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_72e546a7-9ff9-4f27-a4ee-c0380f4874cf">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8c7cfbec-c58e-471a-90dd-ada3288b07fb">Stack Number Of Slices</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_00e74a50-2551-4198-bbf9-543068b46b87">(2001,xx2e)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1349ac8b-58fe-4cee-a88e-cebc9a527fcb">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d6879fec-8680-41b4-9fb9-49ae830739ff">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1bea9ab6-e476-4497-8d8c-79c15bc2ba95">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e655ece6-f396-49d9-9172-78fdea09ea73">Harmonization Kernel Size</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4f9700c3-a85e-4f9e-947f-032999108396">(2001,xx2f)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6b5f1e7c-92e1-42f1-bdf9-6c0e55b18972">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2bd41d06-1da8-45fa-8950-1ee0455063b9">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3065387d-83fb-4a9c-93ee-312f8dc30b8c">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_24773a5f-86f0-4317-9f57-9bb6f78d0109">Harmonization Gain</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cf42ac8c-3994-4311-abbd-185abc5fc43e">(2001,xx30)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_0e8a0459-d4b0-462f-a956-f0872c9aaae0">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_46790239-12db-4e66-8b41-27cb4d13dc94">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_254346d0-8867-46a0-a592-be200d7d3927">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8b56a64d-f93a-4ead-ba90-7a45a3a5b376">Log Subtraction Gain Step Taste</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1933ca00-2a78-45a5-9ddb-7e1b792bcbae">(2001,xx31)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f6f4131f-8365-4f7b-972c-eae4b6ad45ee">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1fe4a339-e6ea-49a0-a95a-99f748dafc79">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_836e28e6-4233-46be-b9cb-13002cebf933">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_0f19972f-1a02-44c6-b70e-8af06db70a1e">Mixing Nr Of Mask Image Numbers</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d143c113-be85-4132-aa13-97d6905d8dd7">(2001,xx32)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_165159bd-86be-4afb-a98f-84bbcbe89364">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_10758b97-c267-468a-ab07-47daba98d0f3">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cd351b11-e8c0-4be9-94dd-fd7718846ef4">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7851b917-9994-432c-b503-6485033d4bb8">Stack Radial Angle</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e6af5a36-c865-4924-b31c-4f5ccd090f7e">(2001,xx33)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4cd0f9f7-9bfc-440c-bfbe-3312425e410a">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d6573bab-87cf-437c-928c-9484bb721d2c">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_66a83b30-1358-423c-a534-77d71fcbab49">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_72990fbd-bffb-4f28-ad64-7fb5d0ffb3f5">Stack Radial Axis</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0df1c0f6-fb57-4bb8-a04b-5520becfeef9">(2001,xx34)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a6ed35ba-8d91-49b8-a6b0-b4eef9e63cf7">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d8db6f9a-b6b1-431e-a650-161ee0ccbed2">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_658b408a-73f3-492b-a58b-0ae2e186509f">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b858890d-25d8-4425-beff-effd1e31ba8e">Mixing Mask Operation Type</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6421f1f4-4c61-403d-a33e-cc2c7193d2ac">(2001,xx35)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b3cc985b-116e-4bfe-a0a1-ab9f7334fb71">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4e3e095f-4c76-4c1a-9b57-9b3e7ce4990c">SS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e0c50848-0585-45dd-a505-17dbf7cb3891">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f9fd8a4c-5e37-4841-8dcc-ca41b4cb6d9d">Stack Slice Number</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9e39819a-94ad-4694-a366-79d7c9d539a7">(2001,xx36)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_db110dc8-4167-4320-a24a-3e6658078711">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a207293b-3f31-46fb-8aca-95e49697928e">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c6668a33-04e0-4d2f-af6b-70be9dc5fca2">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_47a4420b-3485-4b89-bc04-50e369700b2e">Stack Type</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_42fad0e4-4e52-4dfa-bd0a-e08be7b428e9">(2001,xx37)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_18193e04-bf63-40ad-ba2a-a82b815c4c99">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a196b639-2455-4412-b39c-93477537b865">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_73c2382a-54bf-45fe-8da9-eb1f4ff18f77">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b21cca25-b7ef-4e4f-a9fb-be9f7a72e0a2">Mixing Operation Type</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5d702c93-5b72-464f-8850-7d8ce7681a68">(2001,xx38)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_53d21ec6-72e3-451e-9bf8-7aa21e75b6f1">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_61a2f5e5-20a3-4290-8715-6155f8713888">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d89d3321-f12f-4c13-8ee4-820d7230d931">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1b639893-646e-4dd2-852b-334b6284d2ab">Overlay Mix Factor</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0f068950-acd8-4eec-be96-7a4934c2c135">(2001,xx39)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_97448bc2-d157-4755-ac28-16589855ad8d">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ff8b95a6-823c-4a51-bfc7-0885a4e96268">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d02f4633-43b8-4a00-9ffc-46888dfa0ba7">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_baf60bf8-53f8-4155-b8a6-76aa3ddb5d21">Overscan Factor</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e638f372-d667-4c9d-8bb6-5eefb7524edb">(2001,xx3a)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b9afe611-f260-46f7-a161-4d8a36876b02">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_968b6c0b-49b0-473f-9911-8764352d59ae">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_30376d87-94d8-4ddd-aaf9-85da9d069005">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_28050ea5-11fe-4605-a2ca-6e09fd401f7a">Pixel Shift</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a6bc9849-dfd4-4b11-94e7-336a6349875f">(2001,xx3b)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_bae76ca2-c29d-4f0c-b87a-03eaa31c5089">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_48e6e05d-ccb3-467b-bae6-6421582f05a6">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d2778bd7-a594-468f-98af-eba2ce070b09">4</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4512c7ff-4aef-480c-bc90-801c1693c5e8">Pixel Shift Split Line Coordinates</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_90155f31-5851-48d4-98a4-fa8bc892253a">(2001,xx3c)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_732911eb-33da-49ee-85c4-a3a21c724c8e">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_98b00c74-95ab-4d96-9d52-c934dbcfbe28">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5b51626a-114f-4dc2-a652-458a01c4e03c">2</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_33c28a0b-35df-4a45-8596-da83c35bba4d">Pixel Shift Shift Vectora</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3761efa2-596f-4cbc-b435-90680883a6a2">(2001,xx3d)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b356d441-a577-4a3f-9f3e-546d9d800678">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3d3a94c1-72a4-42a2-a319-a31f5a5ed3de">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3b08ae46-0ef5-4fc8-9d67-a0aa57ca0352">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_79b6bff2-01d7-474f-b906-c4c2d49b4d2d">Contour Fill Color</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7b2de960-2fcb-4fe4-913d-557dc515c47d">(2001,xx3e)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_80bc9579-a483-4be2-8823-d4e6416e41b0">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0c64f087-3ad8-4f03-bc39-05766ac699dd">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_21cc1b6e-a505-4c94-8f8d-5ba87d087a0d">2</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_976ed942-2fe3-47a6-a467-fbdb99d23e65">Pixel Shift Shift Vectorb</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_bfe6ee9d-6779-40d2-9aa2-3eb021fc792c">(2001,xx3f)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c2e73ead-cb39-40c7-8529-3ce2331f87b6">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_672ff492-26c9-4cd9-94d4-b39b13724044">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e620f7ba-b80d-4173-bbcd-a2c0c06c07f8">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7993c334-26f5-4661-bc48-2b490ade14cc">Displayed Area Zoom Interpolation Meth</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d35d5fa5-1581-45e6-ba2a-03f53ab5f6bf">(2001,xx40)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3ff8934e-54cb-43f5-b7c6-ffa07d04cbdf">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_24a0de62-e5b9-4f1f-86c3-a26e9b57f851">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_20f900d6-5e27-43bd-90e1-bb053deae4e6">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_71f48792-a732-4e37-9679-23cee4301efb">Pixel Shift Split Screen</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_29235d0a-8a02-45fd-bf05-69b38cfec188">(2001,xx41)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_649a8cb6-d473-4f1d-9345-9f98ca820145">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ae8e7737-6645-4366-8795-cf1070b00091">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0fe842cf-63b1-46a8-8dd2-bd4bea706d4c">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8fdd6f35-67c9-46f1-958a-580bde6f589c">Subtraction Land Marking Factor</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_71f3a94c-15df-4230-aef6-bda66840ffff">(2001,xx42)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_86a48bdb-23df-4775-a3c0-716f0f1ffadf">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d67e98bf-2cac-46cb-a619-4e07f2ab4b9b">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5773bc06-37d7-4837-b0ff-1fadbd26d1ff">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_cf332f1e-e9c2-4f35-9854-4cae52f8cc86">Subtraction Land Marking Active</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_92b15888-2c56-46dd-85ef-cc0cd6456848">(2001,xx43)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e986f302-928c-4d66-91d3-0451964dba19">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f992767b-2730-43e1-88da-d56abe3bcf02">IS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3c37955f-3be4-4121-a4e4-24dd05695b99">2</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ad812a84-20ac-41d2-90c9-69401e550456">Ellips Displ Shut Major Ax Frst End Pnt</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_dd4c2ff9-1e5d-43c5-bc20-5e2ff72bfe57">(2001,xx44)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_587e9c8d-348b-40c8-8fef-3bfdc993865b">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8d272102-c29e-4b6f-a315-7f583b038841">IS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3298f629-9b51-49c4-aba1-bf5e570bca4e">2</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c68453bb-9e87-4a0a-8cd5-71f5cdd8fb68">Ellips Displ Shut Major Ax Scnd End Pnt</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cb9188ad-f9eb-4506-9e50-61c55f9a7719">(2001,xx45)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a98c5533-0339-4587-8339-55dc10bc409f">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_00291211-6cab-47e8-867a-8999389c39b3">IS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1bccbafd-cb06-4ee2-baae-896893e2f8e4">2</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_518d1ef6-1509-4a89-bee9-35e980ab1e5d">Ellips Displ Shut Other Ax Frst End Pnt</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_309be0d8-b7d9-4f38-a05a-620fcc342a0f">(2001,xx46)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_99ed6731-9115-4b65-a9c8-20eae71c644f">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0b507aa7-e257-46d0-8c46-b6dcd8b22e83">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f237c777-58c9-4b8f-a43f-105fa44cf360">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_5d24587f-228a-4dde-8a32-652fb7539dac">Graphic Line Style</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c0d71e04-0f7e-400e-b5cd-64f02e579458">(2001,xx47)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_0d78cdd7-ae4d-4649-bd90-10ba9f8aa7c1">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8a18484d-4217-45d7-8eb3-856f06fffd36">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_095062c8-a563-4ab1-90c0-0bd5d2c97d6b">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_9e97dcea-c1c0-4f09-9c56-c476e961c63f">Graphic Line Width</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_45201584-a149-4bb8-bdaa-658e69369e02">(2001,xx48)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4d85b826-d53b-4009-b987-c0f96dab9456">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0933b0ae-e311-4cf6-a4d6-bb90c37f6205">SS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7caa6506-d245-4707-8907-72c0ba5f3302">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2029d3d4-7c5b-45c3-9928-edc5f808af92">Graphic Annotation Id</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1fee3413-a0bc-4ac2-b9fa-4915160992f6">(2001,xx49)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_cd832b68-9274-489b-a299-fd7282813fde">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f1d4beb3-d0d2-4735-b6a7-5f3904ada29a">IS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a2ab9c01-e9bb-4d66-84e9-b833369da185">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8f363481-d529-4bdb-b845-6d620e980f97">Trace First Image</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0771c4e7-7fcc-4d01-82c5-d537e4863843">(2001,xx4a)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_aef27df9-b6b7-4871-9a14-e4c6f21372f1">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1a12dcd2-8a44-4f0f-8dca-37b566fba887">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_354c8b4b-b5fd-45e2-a49a-a76bcf31f569">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c3fc74b5-247c-4a9e-8cb5-7eb32aaf7bd6">Trace Taste</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e9a7f75e-9f29-4f53-9e98-6f9a7d051e39">(2001,xx4b)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6d2a9833-10cf-43ff-b25c-f0d033446a73">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2b05d70e-6616-4001-aa8d-e68230573be8">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_44d60172-433f-44d5-98ee-8e7a87843199">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8b09f5e4-35f7-4dd6-acb4-6fba6d0eca91">Interpolation Method</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b4b4c96b-1dc5-4653-96b0-7fc50c29f6cb">(2001,xx4c)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_9c68497f-c9ca-45b2-ab2f-f93a722b93b4">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_329c8233-0f2e-4831-92a8-56d47de760f4">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_02449a9e-b46c-44cf-b8ca-2f19e85a24b9">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c44ea8d5-94aa-4693-acfc-0d5194aa3082">Poly Line Begin Point Style</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cba751a4-268b-4391-a392-805efe8f783a">(2001,xx4d)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_de72b1df-e5c0-4e37-8bcb-ead89228426b">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3bc1988c-11b8-4ea0-b2db-7c1d8964f990">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5394bb90-73a9-4600-815b-1249b00e8d70">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_5a3f5b57-8765-489f-9549-3568e7a16b30">Poly Line End Point Style</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3e5bb7a0-750b-487a-9b0f-27dacc3a07a3">(2001,xx4e)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_939ec6c0-56d2-4810-8e58-f88dd026d730">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_66079395-dbf6-4ced-84c7-31d39a6ec6ac">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a7b42158-2f2f-471b-8b5b-c35aaa6f7e5d">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_0dd5f7a4-16e0-4267-b365-1628f46f6b07">Window Smoothing Taste</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cb62b3ff-e47e-40bd-9fc4-289b3ee01cb4">(2001,xx4f)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c384da05-6dff-4f25-ba5a-79a2c81c9458">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_be894c32-5ea4-4a76-b1d6-53c130334e37">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_99495d00-b1b2-41af-8fac-741ef8968a0d">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ee6348e0-4d13-477d-9733-a7fc2a6283da">Harmonization Offset</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_bdf08ec9-adeb-463f-83bf-83e42ced9b84">(2001,xx50)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_82b6d945-d313-4604-b92a-9a92360d3faf">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3f14fe7e-650b-44e6-9eb7-923810dd659d">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5300e73e-c0f6-41dc-b270-4901d0d7158b">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_9039ce38-be42-48bd-a049-701398b3868c">Graphic Marker Type</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b3ab300c-2194-4ad2-baf7-8c38357d970f">(2001,xx51)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_bef62010-de95-45aa-8953-095b53709735">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_09336273-cf99-4e32-a68e-11265322086b">IS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_13148959-01d2-44fb-8337-9286afa3f3de">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f226f313-90ba-4cdb-977f-019ef421623b">Overlay Plane Id</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e677ca57-ff03-40a5-bacc-3a63a65aeba5">(2001,xx53)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7ed76ab0-3dd4-4c82-9b8f-220ede026971">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d2429dbb-a3b2-4ef3-bc4d-8edb871be28d">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_552e70f4-4d8d-459a-9c41-0a2b5d97cdf6">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4d15a47b-14ca-4f90-abc7-8697e6f23f18">Presentation Gl Trafo Invert</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_79f55a79-8115-4220-9343-9e7209267b09">(2001,xx54)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2d2b5772-d36e-41e8-9031-d28ad81d05ce">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_203a9bab-dd9e-4894-871f-9c1cff9c2836">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e4dbf0ba-31ac-4bc9-9b7b-8f3ff7566fb3">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8f4832d9-4cee-4ce8-b7e3-a35c0effabd6">Contour Fill Transparency</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_26f1c5cc-d77c-4098-9f21-d3128f0c5530">(2001,xx55)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_68d25c7a-9f8a-4b67-a279-44fb08acd6fc">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b2b47b4b-c36e-4c3c-bf01-e6f1808c279b">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_25ca9ce5-0cd2-4ca8-89fc-f536ecd9d60f">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2c0d06e1-ef8e-4382-90ee-eefa16ee4cfb">Graphic Line Color</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f0071781-0951-4be9-96a9-61fa5adeb7ad">(2001,xx56)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_da1d5501-6bae-4eca-9d49-886a7dd58599">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9c909d68-d40f-4468-8b48-6023ffaa1101">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c574be12-4f67-46cd-a53f-59ade82ca3f6">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d7ad659c-c3c5-4e7a-ba7d-6d6c23b92dce">Graphic Type</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1943aedb-aa77-4c74-9087-4d7944508d0d">(2001,xx57)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1015f4d9-f3a2-4e7b-b34f-97a6fc960334">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cb95c9e9-ade8-46d7-bd2b-da1b09ad2c22">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2d50e7ea-24e5-4261-b835-dcd4931ed070">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b028c41e-821d-4733-af5d-eaf339bce943">Log Subtraction Taste</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b13428f9-708b-492d-98d2-080d9984b943">(2001,xx58)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_173464b2-a59e-4f7a-9968-ffe79f92d885">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2d8e2157-4917-430c-ad9b-993bc6f8345a">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e62f116d-72f3-4823-9d8e-169b5947eef3">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_9d15f234-f3e8-41e3-a7d1-f8c031c92e8a">Series Xray Contrast Transfer Taste</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_eaffe873-0cff-40e4-9bdf-894fe7c58c6c">(2001,xx59)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f0691b1f-e773-4558-9d5e-335c5210df33">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c2be8c6d-cc95-42f4-96a6-c565245a6044">IS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_df91e8c7-100c-4a83-bf4f-b1e61fae77e5">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_70c1f11e-5ab9-4d8b-9803-c484e9d81a4f">Curve Id</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e3b2e183-83c7-4528-b1c3-a64813af11b2">(2001,xx5a)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_703419e0-b90e-4634-ab1b-2e64457b919e">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3e9d7de9-5783-4d4e-9e1e-95313792097c">ST</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3ec109c3-70ec-4b74-81dc-549e50845a32">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_429132b3-4b94-4254-b923-ba02fc837b49">Graphic Annotation Model</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f20f4754-eb48-46e8-8614-2df3e060841b">(2001,xx5d)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1e45043b-cd97-40b4-9247-23759adac552">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_193f7fc0-8660-42c5-a96f-829ee4d76d82">ST</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4b53df9e-6aac-43a5-88f4-f6c0a58aacf6">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ca7bd10f-6eb8-4532-bf81-e0ca48f72955">Measurement Text Units</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_74ba77eb-55d8-40d4-a19e-87b957a30a95">(2001,xx5e)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3498ddcd-c6e5-4acd-9a91-8970c3c00716">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_274fa79d-fa59-40f3-b40a-734753a826b6">ST</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_381bd337-1639-4cee-831d-a8a7928f4478">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8b461eb4-686c-438e-921a-8ba8111a4cc2">Measurement Text Type</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ba6c4c29-23d5-4f9b-bdf9-0a9c4f4de8e3">(2001,xx5f)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2a9b2e3a-40d4-4a7d-b707-dd30692599f2">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ea62b87c-720e-4f5d-892e-743af32861e3">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f1212119-b09e-4019-9a75-6ee886855a93">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1de48cf6-ddc6-43e3-bd5b-f014ecef71b9">Stack Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9d212056-75f8-463e-8f20-b401bc4d8e36">(2001,xx60)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8fe591b6-a8d6-4ab5-8f5d-04ed0cf4dd27">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_38c47774-372f-4d77-a9fd-b11a54ec4839">SL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8902e521-4b53-4cfb-9881-c9cf37a3d323">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a2c869dc-c580-4cc4-9070-a4cc27e103f0">MR Series Nr Of Stacks</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ea065c44-fbab-496d-9712-7bac978bcca0">(2001,xx61)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2c2270ee-c25f-467d-966e-e44b586fe5fd">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b9eb9a41-f134-4964-ae46-708e5ac07f89">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1e11b57b-eae8-4c09-96cb-9d4f1ca4d53f">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3c29fbff-fbcc-460f-bbc1-9fa5b9d741e2">Series Transmitted</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_559cf877-0327-4ec6-ab2c-6620fafa0a14">(2001,xx62)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_afa7b552-be97-4f2e-9577-e1ccf40c76d9">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b8de9e4c-3bda-450c-9b7f-f21c35aea762">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_849bab8e-8005-4c93-8bc3-14dde02107f2">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_07349a6c-565b-4e4e-9b58-a8942a7290e3">Series Committed</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_000f9a2d-c88b-4891-8e4c-21c625b512a5">(2001,xx63)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_88e448f3-8a4d-4c03-b50e-3720c6b8f74d">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9a669b0f-9f7e-45f4-965c-83377cabd2ac">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_50aebc8a-0b82-49ca-930a-923e16707176">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c890841f-3fba-44f6-8ebb-82f78a2bc2b7">Examination Source</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6ddf8df0-8998-4b60-a6b0-52f719300abb">(2001,xx64)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_bfc1e8bc-5795-4f41-946d-6e9a345e97f3">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_703f8884-b8b1-455d-b327-c984cdf8f453">SH</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_08a09ac0-9d6c-4bac-8389-cd4886eb2a79">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_eff89802-da62-420a-9c65-a71775d552ca">Text Type</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9f0a95fb-2a53-4cbc-be9b-82b4f6b2f37f">(2001,xx65)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ab642497-ff6b-44f7-8c08-e24debfa274f">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_45fd128c-6767-44ed-ac42-0b49d78ed89c">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c09e4035-6880-4b01-ae52-e435c74b3c9a">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f1680612-e7b2-4dce-8a2c-fef31feedfa4">Overlay Plane Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a34661ae-32b1-4331-a2a4-b049fc6a8398">(2001,xx66)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_70e9b1ba-3a17-40a9-a2ef-6b61c5eb6745">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_387b0558-04dc-4d72-b0e9-44fe44897571">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_83ae3d70-440f-4def-a9fd-4ad0a43fec99">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d2cf68b6-30df-49c4-8296-8ed2add69eb4">Image Curve</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_66543549-b108-467b-88cf-1fadc975c308">(2001,xx67)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f01e702a-08e5-494b-baf6-93e1cebf1209">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_73dd6ba8-1f24-48d2-9148-a752de6e4f21">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2dc22b98-4a4a-4cb1-a02f-613ece40f811">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_978e80eb-aab4-4fd9-ad5c-10a8308cbc64">Linear Presentation Gl Trafo Shape Sub</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ed16b7ec-4652-427f-bcd7-4cf917cf58d7">(2001,xx68)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_163643fa-5176-480a-a39f-76d0a2534089">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_69238eed-166f-46dc-9e47-79ba56ab05ce">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_973a6f82-7d90-4ddd-a675-996f121256ba">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_467ee42d-6bf0-4ad5-b8f5-98e1f15aacb9">Modality Gl Trafo Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_196b27d9-5972-440d-80b9-10f039caa703">(2001,xx69)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6760d9c5-e101-4a76-95c2-b7df586ecfe7">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7d1fe6e3-a114-4124-b2ae-3e1c57d7b8ed">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_507dae24-491f-4b35-88b2-1c9196a9b9a0">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e0469b6e-2967-4bd2-a401-9abfc3d28a52">Display Shutter Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_aa4cf3c1-d443-4510-bd4d-0a4d25fbc394">(2001,xx6a)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ba35c74e-62fa-4a47-b92e-7daa1371a595">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8bb1481a-a428-4c92-a5b7-a77c50d58308">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f65d58e4-d5e3-4094-93a8-ddfbc489ce4a">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_5c70baf2-2f85-4892-a01e-b66bca9256d4">Spatial Transformation Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c258fce0-5de7-461c-ab7b-ac3987cf95e7">(2001,xx6b)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_bba0c52b-02e6-4306-b3b1-34b8e0333c04">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e326b921-f5b2-4184-b4ca-a6cd09734fe9">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c4936b2e-2589-4ab4-b934-073edfbf0521">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_00b5c717-fffa-494e-9040-882bfc217c8c">Edge Enhancement Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_210416c5-25e0-435a-beed-2aff27fccead">(2001,xx6d)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d1a14b4b-cd3c-4d5c-bfd2-bd8f65ff0f29">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ac4cc5db-de62-4c6e-9035-0139776785ea">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_58576248-67bc-4d6d-8677-5965c769afa8">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_fba748f1-12e8-49fc-816e-b83a06ad6335">Text Font</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_92f6f6e9-8937-46c4-bdb5-a8c723b5711a">(2001,xx6e)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_deec20e3-0eb6-4fd8-bda4-aa60bbd822ff">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9570a430-f3b7-4ed0-bea9-37f81a57e5e6">SH</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_859cc7c3-58d0-4bdc-8752-c82927e380fa">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_92fee84d-67ba-4c5a-863d-d1f4ffdd8130">Series Type</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4ef185e0-9d3b-4793-9ea6-8f914162f95e">(2001,xx6f)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a5c14b60-bafe-4695-a8b8-16a1d96e53ff">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_747d16fd-9385-4c5f-bc5f-76e1abe2e819">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4e7f7dbb-6c5c-41aa-b451-45af5960b596">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_11472c90-f347-4562-9403-80289125279f">Mixing Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ad9c862a-3326-4d50-be64-3d287a8988fd">(2001,xx71)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1e4e5233-32fa-4034-898c-3d88d783b910">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_bf6add87-8ce9-4d02-8286-ac20de397740">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b4c5bd0d-92a2-41f6-b516-36d0d1a6b159">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b7d22b7a-a80e-4869-a2e0-f146da4387d4">Graphic Constraint</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3a4b9c4c-70fb-4d12-bd3c-d3f40b1381f3">(2001,xx72)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_14334f9d-aab6-4219-895f-7099f5d0d239">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_68f14f39-717f-487c-b440-920030126bdc">IS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1485f873-9698-4e79-9228-a26c0f3475b8">2</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_acbd580b-8e71-44e8-afee-b8540a021913">Ellips Displ Shut Other Ax Scnd End Pnt</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_64ad580c-c852-4785-af14-fe19a3a52fd1">(2001,xx73)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2f1d4200-3398-4a8a-ac7f-6d410239c315">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2db93620-3cc6-437b-b3eb-237385dbfc77">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b97f81a4-3324-4ddf-bbc7-097c4d1fbb90">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8a87d06b-e154-4c3e-9731-6062ea3d272d">Referenced Mask Image Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f593b88a-89f8-4948-ae6c-971ed9f04ae8">(2001,xx74)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_891fa0b9-17de-4bcc-873c-82b5670fa430">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2876763a-465f-4c90-83d9-6ea00acfd739">DS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_bfdaf75e-9f64-4e0f-83f4-74645fee80e1">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_145a4e58-83a7-41ba-bc0c-1f43f07188f6">Window Center Sub</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d3be4c0d-9f95-45d0-ae6e-8ba0e01f2da8">(2001,xx75)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a4ec5508-c9fa-4238-b2e1-01e7684a216b">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_31881e67-c21b-4e35-ab27-490a25615833">DS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_50f180ba-ef3e-42bd-8961-043efc19527b">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_902316a1-937c-40df-b891-d25e07bf2e8e">Window Width Sub</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_13990143-05db-4ba3-ab91-7dcec7138010">(2001,xx76)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_78ddef5c-5ec3-4ce0-b424-012de7fcdf10">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1dfd6568-e2d4-4287-80e5-2db281b2ddd3">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d6344599-cb01-4db2-9f66-9f09c73b984e">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c5cce6be-d6a7-439e-9bef-4a17810685a9">Presentation State Xray Contrast Transfer Taste</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_80097b90-a5a7-4dc8-8077-ad9fec8e77bb">(2001,xx77)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1257de3d-3bd3-4a09-a8d5-7e5ddb9dd70b">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ff0674b4-d8aa-4148-856e-5b4eacfcf421">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5c497240-8e1b-4e60-9cd0-89c4b0ea7cc8">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_93373aa1-a783-4b77-8632-655934b20ed6">Gl Trafo Type</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_101b0194-9ffd-49c2-8e4d-b6855a518759">(2001,xx79)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c60c858f-5ec4-426f-949f-c47a7eaaa82e">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7190aec2-9692-4c95-bffa-629a76ced130">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_11614d4b-7ffe-49ac-8616-a2cd665bbc2c">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a2f0a447-05e8-4611-8991-dab27a168be7">Harmonisation Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a502eb7b-aa8e-4e6a-85f0-d6cd22eafc3f">(2001,xx7a)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_dfdbd4c9-e7a9-4eed-92ef-8bf13a9e4cd7">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1b86ae86-e678-4b13-8246-de333d3ea423">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_416bffa8-840b-46c1-a66f-7e5610d8dd96">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3285e195-c664-4020-940d-de720daa38f8">Window Rounding Factor</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9520c282-1423-4497-9cf5-9a4db183eeb9">(2001,xx7b)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4a8b9a6a-2cff-4f68-a0d8-8b32e3d89108">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8dfaf917-c523-4c33-8d2d-3051e1212aa2">IS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d2d65727-cbc0-4d8a-b675-77fc0cca5ffe">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_06ae8e2d-9e0e-44cf-b4e1-c79003452090">MR Series Acquisition Number</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_880eba32-a1e8-4a72-94ca-1f32a39d6ecd">(2001,xx7c)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_27cd523a-f47d-4f2c-97c5-aafcfc3d5edf">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_48ed806e-2e82-4e91-9629-7bdc19a1e6a1">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0238ab08-baf5-4128-bff3-40d319942450">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_85c6b823-8a59-4a05-b5bc-27485d12be22">Frame Number</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_26c9eb21-91ea-4b96-aaee-089ea79a9ede">(2001,xx7d)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b24c83f0-4ff8-401b-b4b3-f1f62c5be1b0">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d4f0edad-105d-4779-a01c-aa46a1c64778">OW/OB</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3c41e1b3-9bc5-4e8a-8e23-d6345253a1a8">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b426d493-2a3a-42cd-bd7f-dcd893d2df89">Frame Pixel Data</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e6486145-2f4c-4c60-8858-ab1b69700ec9">(2001,xx7e)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1f3344ba-c9ab-49ab-98ae-30514c0005b2">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d7ba7271-6094-44c1-8811-627680d2159a">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9817eae9-acb8-41cf-9dc3-7c19d4ba9096">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c42bb4e3-74bd-4e6c-bb20-f159b00d9463">Edge Enhancement Gain Taste</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f259760f-003e-4ac9-a101-cb7abe04b94e">(2001,xx7f)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_756d4395-cb51-456f-ac72-254f54237699">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_29e89ddd-0562-4695-810c-0fcbb89e98c6">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2ad33e8e-20a2-4f61-b3ec-27a4034d5b5f">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b1cc12d6-9ba7-40e1-98be-3ae8784f87d2">Edge Enhancement Gain Taste Sub</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_324ba15d-c5b8-4c8f-880c-2f8961552816">(2001,xx80)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_31cbb57b-0df2-45fa-b649-2f1e4d63b932">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4f136bb0-611f-4396-a777-57c6a3347e0d">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b2895327-789b-4ee2-8396-3d589cf8ff5f">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d3b1e86c-6fe0-43f6-b7c9-dce6e3f5d6a1">Text Anchor Point Alignment</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_40cb2358-9c5d-4464-8d96-59a37dbe45cf">(2001,xx81)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_872e49af-b4dd-40ef-8cea-49ab8b31f23c">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7aef8ed1-09d0-46ff-8f24-665cda94766b">IS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_20da578a-a096-4268-810b-03bf8eaaa116">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_170a1f41-4d6f-41f8-92b7-a76d2303dc1f">MR Series Nr Of Dynamic Scans</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_08a16cac-001f-492c-9056-51e9c050c4f2">(2001,xx82)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_648d4597-89ca-4dbd-b160-3a2b4a20b15c">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2b6b6fce-05c2-4527-aad4-c67e4b8fd691">IS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9cac828d-bb29-4ba0-a257-e7d56d3c5ffb">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_edc79eaa-e724-4c5d-8ac5-4d2df21ffa4a">MR Series Echo Train Length</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8f9a1636-b6cc-4a23-bd1e-2ffac65c456a">(2001,xx83)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ff174353-722b-4194-a5be-1c212a738706">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8e54d7e3-2eba-4f8a-a47b-47ef89456123">DS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5cbb8fb9-11a7-4fc8-b049-5448cc4fa81e">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_cdfdf88f-f05f-4ed3-a54c-06176b9e60e4">MR Series Imaging Frequency</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_94ada068-c283-4239-be1d-e9c2cbf952ee">(2001,xx84)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1610dfe8-1894-4c15-9d9a-d71a1b75f3e2">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5c5b89ff-bb9d-4ccc-a6c8-44b07139a782">DS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_96899a33-736e-429d-8d6f-846b487ab975">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_73bca83a-1838-4aa0-a051-eadf6d4a97a0">MR Series Inversion Time</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_05c12b7e-653b-4545-8ee8-fa1181d4a75d">(2001,xx85)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_91d6eaa7-27d7-4e8b-9d10-8e8c84445c58">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cddba1da-79e9-41bb-8c43-ae97d4f4cc62">DS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ece72f1c-e42e-43ab-a778-06117109581c">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8c8da47f-c6e9-4c2f-89d0-77aeeaf16835">MR Series Magnetic Field Strength</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_96f0a6fc-50ea-4995-abd0-4e125b7c36e5">(2001,xx86)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_37c82d5a-b910-4b8c-b290-b6d910013b89">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c5c3d0ff-0272-4b97-bffb-9f184ff0571e">IS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_37772f57-929d-49bd-9c0f-d6c4ef3e46d9">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d0e264b2-e412-4e6e-9a5c-fee10d93a63a">MR Series Nr Of Phase Encoding Steps</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3f792ed6-ea5e-4c4e-afb5-67b1d3c6ec21">(2001,xx87)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_70ecd301-cbd3-4ce5-8bd3-be03ca4f5659">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9844e176-636d-40bf-8d4d-6ce796fd418f">SH</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_baba36e5-4570-469e-ba77-957df45cdde1">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f72dc4ab-554b-4a3f-99a9-ffb04bb69462">MR Series Nucleus</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ef41eb62-4d6c-4bd9-a499-42e01f6801e3">(2001,xx88)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8cdd60de-39fb-44ef-a4f8-e8f51a0a6bcb">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_39b2eaac-9efb-4eec-85f5-7a12bcd5c10f">DS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5bb8cfe8-2d3f-4818-a1c7-f23b5eb08ede">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8964702c-8021-40c4-bef8-8c85780c4292">MR Series Number Of Averages</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9a7d02dd-9a9e-4370-805a-f16588f899d0">(2001,xx89)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1eb2f3c3-4c3e-44bc-b38d-1f0f885e10e6">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0bc061b4-9aae-4ec8-9bf4-743d95fa2f85">DS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c2c78b91-ae5a-447b-a954-35a175d55751">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_016a5512-c4bc-4d5f-9070-f8112b166dda">MR Series Percent Phase Field Of View</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3d7ff8ad-3b39-453d-baba-64ee585c0479">(2001,xx8a)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_99d79d17-f53f-4181-bc34-304b0b41de2c">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6d573e77-8da1-40e0-8bc4-a1f99d82aedc">DS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_74bf224f-893c-4e11-827f-ca4169edced2">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f9fab020-e256-4b7f-a962-f1bfc7137562">MR Series Percent Sampling</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_bbf8eb08-2c35-4d2c-9e49-b3f32d4a076b">(2001,xx8b)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e4be2806-0c0d-44ab-b4f2-2360d6f893ef">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9dac2e40-601d-42b0-b87b-626d0edd1499">SH</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_99d1ecd0-7f2c-4da8-8eb0-4272b0e9109c">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_905f683b-1d98-4289-818e-edf31b383589">MR Series Transmitting Coil</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_859f0757-c588-45e6-b2ef-c5ad4b582e9b">(2001,xx8c)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3ff5d733-3ba4-4aad-aad1-fcf9a2a30028">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7c4337d4-13f2-4e25-a966-c9b51e9c1bf9">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_eee0d890-b911-4a6e-97e2-8928c032c270">0-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7cf7933e-4d12-4cf5-93f9-dcf6599cd341">Needs Processing</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f6258591-d5d6-4daf-84da-90959314f59a">(2001,xx90)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_0d3eb53a-cce7-433e-9bf0-ef22a4bbc2ec">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e0cd922a-fa6a-49ed-b459-5f1794c63078">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7a085ce8-d273-4739-961c-9e59a03edb94">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_03ce063f-1079-40f5-90b8-e7f640c55861">Text Foreground Color</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_075979dc-deb7-4fab-9b8f-eee24ae8f3fe">(2001,xx91)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1c17612e-8ea6-4bc6-baac-a4bbdf7ac0e5">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_00cd901f-1e18-4464-83fb-2467b3b5ed30">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_25ed9c7d-5ffb-4e5a-a7ff-be24fe2c96bd">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_39da9bf7-1393-4cdf-bdd1-07c448032260">Text Background Color</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_bfe2bbbd-f851-4701-bdfd-9aabeb79029e">(2001,xx92)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_10b17eb7-862a-411e-a5be-7a2db7ef0ca3">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4db6b4ef-34d6-465e-b81a-df3c5eca6826">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a89f2ff7-5ac8-415d-8d76-80e96f6128fb">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1918bba4-9ef9-4f0d-a3d1-ca9c7a898e4f">Text Shadow Color</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3ef22eda-20f6-45db-8e2a-327ab3a08ccd">(2001,xx93)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f5874008-aef2-48a2-87bd-a33f1868bca1">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_685fabda-c4bf-4524-8049-f428c3825542">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_623372d4-8f73-4ff0-a2d6-ab0d2cb7e0d5">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2fd2244c-e88b-45db-96bf-09abf28a38ca">Text Style</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8e2ff357-701d-4721-a4cd-a6ebef945d13">(2001,xx94)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_40a7b950-4d6d-4461-b0e4-6cfd08cf28a2">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cf57cd42-6f33-42cf-8360-5374524f38db">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_70652513-db84-4889-976b-cc3224dc3bec">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f7266307-3e2c-4894-9acf-36d7b7f999de">Processing Order Specialization</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_dcd97902-2c3b-4b79-9e7e-51e1ff697b87">(2001,xx9a)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c8568726-e623-4934-a907-1e214f1d8fba">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9a91643d-f7da-473c-90e1-bce0281ca082">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f082bea5-61d7-4f65-8252-4be78ec88d50">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_45ac0ddf-7c2e-4250-b016-f05f8aec81f4">Graphic Number Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_82395982-c54e-4972-aaac-2391bc9336c8">(2001,xx9b)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2c287638-30ab-4483-8749-ffc7b3095745">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_999731dc-3a3c-4563-abf9-f86b328eb5be">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_96d0ceba-12f7-41b1-81e2-779005894078">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ff4ad72c-38b3-446a-90f0-065e966c9d55">Graphic Number</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_08eccf4d-3d74-46c9-af09-fe50640b2673">(2001,xx9d)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_35737eff-019a-4e48-b972-c50977ef604f">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0f819280-ce88-40c0-a108-725daaf95ac7">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ab2cc4dd-e64e-4846-ad9d-92ffb762bf89">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_070419f1-ed1d-4b7d-954c-e57fd55c22e0">Subtraction Type</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_aaf6ccb8-8117-43ef-b546-ecca571e17ac">(2001,xx9f)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_57658492-ea91-44ed-b9f8-bfae66adef88">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_84ff2d94-0e75-4976-bf8e-45f538b8f472">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_acd555ea-3e7c-46d1-a898-040630f943aa">2</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_9096e9b7-1830-4c5b-b8ab-57fb2084eb42">Pixel Processing Kernel Size</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1b0248df-5029-4a37-a005-03ffb02283a1">(2001,xxa1)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2967d122-502d-42c0-afca-84339bf8b674">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f7ca9b94-ef20-4a89-b9db-2e8b362f394d">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_da0fb82f-604d-432e-8322-21193d292a90">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8ca23ae6-9d10-4de0-b8c1-8990b880584f">Is Raw Image</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3cfe841c-3b72-4fca-b058-68101441a258">(2001,xxa2)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a3d1ef83-67c4-4594-b6b6-413f151f9939">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_94737b41-5a79-4e6b-89fc-dd934ec2e6e7">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_89152194-34d6-4a33-a211-07f4112aadfa">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1fa78492-3e1a-42c1-950b-b552be1e8cc3">Log Subtraction Curve Taste</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_eb5846bd-ee97-4d36-bb26-69d6b4c081ef">(2001,xxa3)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a0202b0f-e49b-4ea0-8c4f-8b3c60b4e1fc">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_88eafc09-b1c2-45a7-b75b-b4360abf7d10">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2d74a839-df30-470d-bbfe-ea0ca4281705">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_9efa3278-2d5c-4c46-bb5d-8b9e6d8a85cd">Text Color Foreground</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f1585de5-6bee-4572-8ba5-3a05bcbf803e">(2001,xxa4)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_19583e6b-b2a4-4dc1-8ed2-a92490ad1c26">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_913c8549-4a64-495d-9d7f-c76a600b83ad">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_fff57c86-c46f-4c67-9b40-061de8dcd903">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_12368345-e95a-45a9-8b4b-c104e4212c69">Text Color Background</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_77bb10a5-ce35-4df4-86f5-734d2812e161">(2001,xxa5)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_dcf2bfde-79d3-4e54-ab50-347b698b71f1">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_42890df9-f453-4a11-91e9-cf914815e4a5">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_73223825-49c9-46f8-beaa-da532394099f">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e4f60b08-c2fb-4b56-ba83-9965f3e2fcb4">Text Color Shadow</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5e1c9e7a-df37-425d-aa7a-b6bb27b762fe">(2001,xxc0)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4c2431de-9c0e-4ccb-bb11-583695df63de">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7acc4c36-7916-4819-b533-93ee75a85ff2">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_96de8893-15ac-4917-b93e-7fd28a22d2f9">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_bec544d1-ba15-4452-8d4c-2d63bbb4f8f3">Content Item Identifier</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8f46c697-500c-4df2-9efd-ad5b854ea750">(2001,xxc1)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e2dc3f04-bdd9-4930-a7b2-c02a9d5b3c0c">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b6300630-29d8-4c1f-a68f-16fc0d5e45c2">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a4845aea-ff7e-40f3-ab0b-2b2105c80aee">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d058f3ce-7a90-4df8-a0f5-c49882a30ec3">Nested Object Type Name</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_898014d8-7ad3-4508-b940-ced577f91000">(2001,xxc2)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_cea84ae3-9139-4967-ab3f-58deac67d48b">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_bedb6f31-1d1a-44c3-8f9f-40568d85aedc">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7c5c12b0-a822-48f0-a4b7-c6bfeffdb265">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_9d8a3d43-5cca-4515-9db7-a163e902c276">Subtraction Rescale Factor</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ca88b5b2-4cc8-4af3-8011-066fca04c33e">(2001,xxc3)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_695e4955-9700-4d48-ae03-c3a95ddb4c95">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7c7bbb21-1f7b-4cde-a408-d7a4f69a93a6">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8b6c7635-5b98-4b55-aa6d-f37a12008913">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b87c0a70-2733-448e-b3fb-ec25079a2a80">Subtraction Offset</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_36f1de8b-58d5-42f9-8a52-26616f38601b">(2001,xxc5)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2005552c-f2a5-4ec6-ba3c-2cf1e9cf22da">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_545021b0-0444-4470-973a-74f71e8c944c">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ea9d1f9f-f1c9-4b6f-9842-cfcc0ccd2271">0-1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_49e9f4be-37d3-454d-9cec-f5ef623aa9cc">Mask Image Lut Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1492f4e2-e336-456b-b4e5-4a7aa67073f1">(2001,xxc6)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3a2ff7bb-5a80-4334-b7aa-b2ecf4e3f054">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_95244015-799e-402f-9d36-a3a9b7a7c9e2">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ff4cdac9-8036-44af-98bf-cc0bcc5d62f6">0-1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_023b972c-7370-4365-9f59-f3a418d4f259">Gain Lut Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_725269d9-d653-40ea-b03f-1c3fd2e608c0">(2001,xxc7)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2191f4db-3d1d-4e21-9c79-a051847f154e">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2f1dfe4a-d4ad-45c1-99ad-ea1ad412fbc9">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_99dff890-7d70-47de-864b-5a77a62b226d">0-1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_5118395b-2fac-4c36-b2d9-4a28e02287fe">Contrast Image Lut Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_221aa254-b47b-40ed-804c-5d072fcda02c">(2001,xxca)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c0ac925e-5e6b-4042-80a7-7b0b1122263f">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3f14b408-9422-4280-ae10-2ae4062af988">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_db0be053-9582-45a5-93c7-b0bfbe385b17">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c8daff18-4067-4357-bad0-5a1521eac368">Reversed Modality Lut</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1d00decb-1c95-4e73-87df-74797fd46821">(2001,xxcb)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f59450ce-d815-45bf-a92b-64d9538e84d0">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_90ccbc70-a179-4bc6-b3a4-9c8c65e113e8">IS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e253c9a4-df14-4d75-883d-99df4c0475d3">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_328acdb0-fff6-4370-83d8-b9320a7d7e2c">Redundant Overlay Plane Id</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5a2c3cdb-5952-4fc7-8597-0fa74441a3bd">(2001,xxd0)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c1d31c21-c7b4-4d00-a27c-ee7a2295b4d5">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a8bc4d4e-cda2-4c78-b7a0-585e622b3b71">AT</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_33ebaa22-d072-40bd-856c-d9ce9dd2c91f">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_08bc955f-282c-4bfc-922d-b65b9f8e368e">Frame Index Pointer</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6567854c-5940-43d6-9f15-04f626055c2b">(2001,xxd1)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_dc66e05e-d63d-405a-b543-56df86812a61">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3304a610-7a0f-4f32-9385-598f19916e36">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_de0d2dcb-01b0-4210-be40-6ea43489b3f0">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_40475243-eb95-4719-bf08-01eead4e516a">Index Number Vector</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5bfcf731-578f-4e0e-bf75-a1e5e8aa9d0f">(2001,xxd2)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8d5ab6e3-260f-44fb-ae32-a0bb3137478f">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2795bf2e-6610-43ff-99f6-4c89f1913168">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b1154914-5e1c-4b6f-a699-839797f3855a">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_30a7fbf1-3d48-4cf2-8243-7353c3ce613e">Frame Detector Number</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_45416fa7-af62-49ac-9b0b-3ef7e0f723ec">(2001,xxd3)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_cbf53bed-06d0-4996-b3fa-2bc571536ff7">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_88d9a063-afc9-4a45-94da-783d8b2f6634">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ae85c473-e809-4372-b1cc-36c97a312785">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_23fdc6b1-787f-4f9f-bffc-3b3651353a5c">Frame Phase Number</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2cfa0585-ada4-4387-8135-68b914e638ab">(2001,xxd4)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3c26f764-c6a9-4e88-b164-038bd617217b">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e1d71b61-e348-413f-b3e6-07c989b075f9">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f5c710fc-3899-40b1-b18a-971983b92f49">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_0ff136d3-7c77-4b1c-b53b-1686184a56c7">Frame Rotation Number</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_449bcc0a-b567-4967-a0cf-c47b1935737b">(2001,xxd5)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e8339bb2-bd45-4acf-9e18-a4b3d2d18e50">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_28ddfa7c-09f5-425d-8408-7711181c50ae">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7c4b0c26-b7c8-4478-b928-37f5c1e13dcf">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c08bf5fd-e92a-45a9-a432-7abbea267e43">Frame Rr Interval Number</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_222ce033-e245-47d2-af6c-e3a1e4ffe66b">(2001,xxd6)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b2e99321-630b-4670-9194-ca79f69d357c">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a07a832f-144b-4bcd-9392-fa3287479fc5">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_839024d7-0630-477e-ba3b-2806fc36f24c">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_05069d25-ba63-4081-800a-e1b4a0fd70ad">Frame Time Slot Number</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e6593038-6de7-43d3-836e-cdb2dc62caa3">(2001,xxd7)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_51b0be65-87e2-4c4e-a44e-4d9b976c8046">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_69f91797-263c-4a81-b621-97923b3b178d">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_38611001-d296-4c5f-b030-a9f02712df86">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1c8d120a-67c9-4931-9b6d-5fe57f176ce5">Frame Slice Number</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7681cccc-1a93-4aae-9082-27a3adde7edd">(2001,xxd8)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_98a77f29-73f4-48f1-80c8-3eef73bd1f50">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e245aa94-b850-4abb-967e-087b15c188f3">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_55ff4d01-fa61-4556-aff4-9c674c3d571b">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c46ededc-9137-4d64-a566-6201955705d8">Frame Angular View Number</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0ca12a49-6c1d-46b3-bd85-7b2ff5e5ac4f">(2001,xxd9)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e87ab6d5-39df-4d03-b5f5-bdcab9e6f0b0">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_410d8892-ef43-4977-ac7e-a00cd8a844bc">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_af77ba2c-b0f2-4256-bea8-94d25cd1d244">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_bb285093-710b-47d4-be20-7005fb7f946a">Frame Time Slice Number</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b57c5f50-462e-4297-9a50-d650c5b01be1">(2001,xxda)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b6909a5b-f910-4124-8e32-8064d1df5c32">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_087f278a-a807-4e74-a0f6-2c819901218b">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_35afd239-904b-4293-aa95-10e690571d65">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_db2dedcc-c25e-4c66-94b6-293ed7cc0879">Is Arrowhead</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c2f5a485-fb5e-4d98-a2b0-71a10dcde4b7">(2001,xxdb)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d4f47f34-f660-4929-a879-e03374971574">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cce6f332-82ea-44e1-969c-20977045a617">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2908d9d1-14cd-47d5-b218-76c5dcdf337f">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a0585dbb-cb72-417c-9ec7-9b11f78042f4">PET Rr Interval Index</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c97ad5d0-0c74-4007-a011-79af177dd16b">(2001,xxdc)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_51640adc-9e0d-4efb-a843-beff6f6670f2">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c7b6369c-0cc5-484b-b5eb-371d82843a7a">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_85be1749-8f25-4571-bfb0-adacbd7ab4d4">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_9ec7357c-8353-4bb7-ac27-f87220883b45">PET Time Slot Index</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b710f890-f4cf-4332-b8e5-908adc644f98">(2001,xxdd)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_385c2752-c311-49d9-b1ea-a03a96131dad">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2593cdb0-5150-46fd-9027-77ef7efd2a83">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ec4427ad-84f1-45c3-a109-58ef5a009b46">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6a8fafe5-17a2-41a1-85c3-0ce454f2e0bb">PET Time Slice Index</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7bffb5db-15f3-4925-b6f8-f646d74217a1">(2001,xxde)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_9de24b1c-5db7-47ae-bb90-f6f4dcef7a14">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0882ef0a-3cd0-4321-a151-0abf89c1f260">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8cd062b4-a193-4149-af16-b1386a4c6150">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b567e102-4eb1-4a4e-ba98-ba1ce7954c0c">PET Slice Index</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ef096685-8494-4d37-b155-fdda0d13c0d7">(2001,xxdf)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_742c6037-9f9e-48f0-a68b-583caf21418a">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_542f1620-7389-49a3-8b8e-a2f164a70999">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_61470961-b104-48b0-9578-04e14a877285">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b862acd2-2c8e-44a2-afec-c75a56d769e2">Voxel Number</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6e1d27c6-8ffd-4933-a48e-3ff58d356aca">(2001,xxe9)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_dfeaeab1-4d2d-4f29-bfdc-4a30823d2d19">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0490bb74-6bdc-44fe-86eb-6cfe8bfbfa8a">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_fa77d2eb-b479-481d-acce-8475f1f801f0">0-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8a643cd8-fb80-480f-85d5-5aab5e609de1">Per Frame Voxels Functional Group</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9824191f-69ca-48e8-868c-03b334b588f6">(2001,xxf1)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_18e84b8b-9987-47d0-a7f7-70d54b04b441">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_603f9d88-49cd-4fc9-835a-bb967214fb50">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6dfe2a61-5b88-49c4-b6f3-c994e20484c5">6</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_db1cc549-1782-4cfd-ac1c-17aac271efdc">MR Image Prospective Motion Correction</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3bac7b68-b590-4258-a5e4-6c8755241585">(2001,xxf2)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e7072192-b396-4990-88d5-7a8cd9ee484d">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1d205068-fa3f-4baa-8e82-77bc608751c6">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_db6e89da-9f6e-4504-a2de-899338b93889">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_62361b99-014b-4ba1-9cb9-24ec84543bae">MR Image Retrospective Motion Correction</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_90028f4d-78e9-48cf-8e9a-9c2201782282">(2001,xxf3)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_af86c884-f78b-4474-b493-ded620e40c64">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a5ff62a6-55a8-4802-8ee5-5553ce3a43a0">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b11b5270-5db9-4a96-a3a0-2c5c6336767e">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a4c4027b-2d2c-4760-b447-2e256f2feaac">Dynamic Linear Voigl Trafo</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_59d86592-e4a1-40ba-a0bc-1057d1317f89">(2001,xxf4)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_5c47b0ba-a417-4f46-8894-6e1eb539322b">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_879cb7b9-2ffc-4168-b3a7-4911fed44446">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9d291b62-23d8-49b4-8044-1340b053fe52">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_9956d16d-0cf0-4dce-9055-af3096ed3323">Color Key</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_62e4c316-733c-426a-87f8-1b1d41fcdbc0">(2001,xxf5)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a036e13d-2ea9-4db8-9ea4-fd1a2a8599e5">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f8cce32e-9533-456f-9db3-77cd161f89fc">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_80739780-7eeb-4ca3-b9ee-f363451f6f0d">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_37219911-2b28-48dd-8080-fa06ffae4610">Rotated Text Allowed</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_012d918e-7915-4ac8-ab6c-b6cbad2af6d4">(2001,xxf6)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_46c5b5a8-a730-46cd-b797-dd736da01adc">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b53e3b3f-eba1-4a24-95ea-f713185fa8c9">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_862d5644-6526-45ce-9918-9e2f68233718">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_82c46078-c8bf-461c-83e3-e007bca2728e">Number Of Represented Images</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_354b8916-7580-4cd7-b36d-f069f8583cd2">(2001,xxf7)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_30d64212-9cdb-431d-919c-c3483ddf5db2">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_53a55f89-6060-4aba-89bc-69b45aabc86a">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_19147a21-06e1-40c7-8aa9-2be34a9acd5e">0-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_54aef434-39c1-4311-809f-265604f4cd46">Data Type Icons</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a4ecc794-8742-4482-9e16-4acc694b0f36">(2001,xxf9)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6b1d281f-80cf-45cd-bf70-dc4faa682535">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f0118301-7dac-4e31-a8b5-8e139cedbcf4">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_21c8b1ad-1920-41ce-907c-e1d46a5af399">0-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ac06f9bb-cbab-44bf-bf7c-40ae9a7b9683">Flagging Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c5e5f332-165d-4b05-bb2f-a480fe52d998">(2001,xxfb)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7df47b71-7f6c-448e-9755-b136ac6c72e5">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f6ea16be-f50a-42cc-b7dd-59c0bde4c608">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1e3580bb-cdde-4c26-97d0-77ab2bf469ba">0-1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6df50310-cdfd-4a10-9db0-5b478daca794">Bookmark Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ef804e88-9a25-426a-8c5e-dce9b224f1ff">(2001,xxfc)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1ff38a1f-9299-4236-ab1a-64c64cb66c44">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_483d6164-4c0d-4cee-835a-89638b3c0958">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c3f47c4f-0505-423b-b073-b6bacec91fe5">0-1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e2671982-b421-40b9-9bdd-98e45d8451cb">Ris Code Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9b18985f-6f0b-4345-b3ef-93ff64503bf9">(2001,xxfd)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d3be0ab0-e31b-42fd-a838-c4fc47c99222">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7d80e8ad-38c4-45e4-b707-34640b688d17">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_549ac60c-c39f-45ad-a6ad-bd02ba068e02">0-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_04685b39-7a68-443e-b4c8-f9375c6883a8">Workflow Step Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_04effd1e-5718-4874-8c33-71753f2c7231">(2001,xxff)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_86a8fd6a-396a-4706-a75a-5a9b8c83a432">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d242e6f8-9ac8-4330-84c0-a1293d19c919">OW/OB</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_091f0ad2-0e20-48ba-b729-59fb0ad6b4d8">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f58e8827-d63c-4a79-9b4a-c12f3d151921">Volume Pixel</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2da17494-c782-42e1-98be-0833b96d1fb5">(2001,xx01)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_977dbd69-043f-4905-8dc4-dceb9a567f1e">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2d90445e-2444-433f-8e31-57a88e406e32">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_88ffe7be-9fec-4449-8d09-2b2b544b88be">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_dea36ca8-18fd-4d51-b33e-a714bca331c0">Edr Setgp</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f66016b1-fb6c-4dfe-b48e-6fb879f470c7">(2001,xx02)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2ea24fc8-6b15-4148-8fe8-78bac7ed2e52">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2fdd09ba-2072-4c6f-b9b6-1a5249897ac5">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f44f66a8-6ecf-40cc-a162-ff7529ae2cb4">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1e992b66-36ed-4dcb-a900-274503f24bed">Edr Setsk</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1e8783be-705f-4762-b318-2bda80fdb091">(2001,xx03)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f218750b-a57b-4c35-9572-a7654bb5aa35">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_79ab4604-e4f8-423f-b82b-4898d1a3a34d">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2e1f0fb5-3862-4cb0-8ab4-fc29d41e5a10">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f97d1173-f324-4eee-82e8-d4bbbbb24506">Um Rank Type</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_19844a80-74fa-4b5d-9d19-d943f4671f41">(2001,xx04)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_dd929e0c-fef2-4068-9b0c-2b2c71fe554f">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_fdba4974-1870-4040-9fb0-8042e1ca9abb">SS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_979f52dd-ae28-47dc-998f-2b875e7f54bf">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8c918cab-b2f6-4216-84d7-0d4706dcf3ea">Um Rank Number</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_344918d7-6f3a-43e5-a827-4976041d1d36">(2001,xx05)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_35ef379e-0dad-47de-aed4-b44fc178fd88">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1e2ceb2a-6c3b-4863-adb6-45f9d55140b0">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9c170e21-6d95-429d-9bb4-08cf77e7623b">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_34a9952e-a2c3-4b5b-b767-fb189155c642">Um Rank Enhancement</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d6a52fbc-7e20-41c3-9a92-fa3695aee511">(2001,xx06)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_59968523-e2f6-46c1-9a04-0286f2f82687">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a9408dc3-98ef-45e6-828f-cf336ab86f50">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_97501459-b7b7-430c-ae63-2283ba1f6337">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_eace580a-f39b-43d5-9199-15f8cd7fe91d">Um Kernel Size</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_147d2909-d69d-447f-8640-d0b6e84c53e2">(2001,xx07)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3ad107fd-d913-4fb3-bd97-3a3aef987861">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_888c3d2d-d718-49b2-8de2-d74b856c75bb">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4a4cb7a2-e76b-466f-884d-e1000345acdb">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a788e31f-00fc-4f08-ac95-cbbca900a5f4">Um Gamma Type</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5133222a-681c-4216-b50a-64022b6bd1f0">(2001,xx08)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6b3c6ed6-0485-49a3-a57e-1d57095e5ae1">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2334c0b6-3c55-4d0b-bad7-1b99c308ebc4">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_73e994db-ebf7-4bde-a109-f49c503cb65e">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d28f626c-b6b7-45fd-b248-3662d83f57e1">Um Gamma Angle</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_84eb7349-0907-4245-a566-48b0f7ec7c58">(2001,xx09)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4daaccf9-4985-4dc8-8d4b-ba529ae2ecab">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_470fed37-2236-4f3d-a709-c4f85b1107f9">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3dff43f2-18c9-4b25-96e2-688a961d4b97">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_aef7ff4c-708b-4088-900c-8df41c7f6c34">Um Gamma Shift</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5e38251c-2d98-4058-923a-a9ff99d37135">(2001,xx0a)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_cbfaa8e8-91fd-4275-9e61-594c920de816">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1587b014-5b87-4f2b-8424-0ae14c47c75c">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_869e8081-f6c3-4900-9a19-4dc67bb0c709">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ecaaa208-92c0-404d-a616-f55fc8627b94">Um Gamma Center</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b090458b-a141-4923-b0d4-6eb5e0acc1a6">(2001,xx0b)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4d0c134d-f18a-4092-a771-cb425c0bc10c">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6ba92fb9-abd8-4c6f-a18b-0963393357cf">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_75ff9bf3-b0b5-40d6-bf07-f6fe495d1d86">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3b3cf695-b2d3-4c4c-8141-777633948cb1">Drr Contrast Equalization</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_846cb72a-cd3f-46e1-8577-5a0250d1db19">(2001,xx0c)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_120a18b2-307b-4f79-a4ea-0523a917369b">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_64f6b6d3-b0b1-4dd6-9ff9-f6c6f7cb9463">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5f097906-5d5c-41e8-b503-a873380cc890">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c46b9a89-8eb4-47c5-9bb1-afb7c62706f8">Drr Contrast Equalization Kernel Size</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f3cb9009-4246-429e-bbd8-96b7f3b7ec04">(2001,xx0d)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_82f530a0-734b-4305-99d9-7f417a3ffc3f">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_57f219dc-236f-413c-98a0-a4a351e7b52a">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d538b24a-fd1a-40b5-a834-52ccddec1302">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1553d864-c5e6-4b8b-9430-f1f614d71c38">Drr Sharp Lut Type</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5bf28f14-f784-43b2-8aa6-099d7a72e0e1">(2001,xx0e)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1d72e5a6-6f00-43ec-b3ef-d166e47a1d86">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_65295275-3a82-465d-a1e8-0aa39b39b0b2">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b907399e-3663-411f-9ab5-73305a92132a">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_cdc42c7e-a301-4624-bf53-192ca286803a">Drr Sharpening</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7ee45d01-256e-438e-8be1-47be278c008c">(2001,xx0f)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_00278dd9-7169-479c-9373-b48cd0f11669">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f4178d52-2e2b-4ab7-89b6-39ac6d849e81">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f31611ce-8325-4cc2-bf05-b9c675fe7506">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1d6dfa60-76a2-45c5-bae2-44d95e4b4de6">Drr Sharp Kernel Size</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a784a7a2-6317-47b4-96b1-2eae94abcfaa">(2001,xx10)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6c4e4a4d-aebd-4c4a-aed3-51e6c94ecad9">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d92ebf08-a73c-4e70-8b15-01891ddc868c">SS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e0f291d0-68e6-4f41-980c-2a7ae3ea145e">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_14b93922-db3a-4897-9376-1fdbb919533e">Drr Window Width</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_03bb30a5-0458-4dd1-883c-dd415dd962b5">(2001,xx11)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b63a6803-7040-488d-9408-b9a0229549e4">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_749a683f-33c8-4de6-a758-ad89e0686c0e">SS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_db891de2-2db4-4987-bc91-d31fbf78ff79">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_211338e4-976a-42cc-9c0f-af336940d1f7">Drr Window Level</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_43e1974b-3cce-47b1-8f0a-fde843dd5cd9">(2001,xx12)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_5d71bb15-3b60-41b8-839e-8194351b3e9e">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a338b504-8e29-49d3-900d-80d2fce9b820">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b893516a-c840-495a-88b3-a29802e86af4">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_5b1baa94-16dd-4cde-a3ad-40ffb1a2bf8d">Drr Lut Type</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e5d8e5ce-819d-42df-8e60-c26134dd0566">(2001,xx13)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_696c96ce-2d44-4ba8-a3e9-1f1ad42986eb">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0f6b4151-44dd-4533-9c90-8beebd803423">SS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_bee6e1fc-5237-478a-8a9e-44b5d861d72d">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8c7a6532-b41b-4f36-86f5-6fe00107a95b">Unique Processing Mode</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_398e24f4-b250-4b94-be98-bd3284a1edd8">(2001,xx14)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2b7b9c7a-51b6-48bc-ab2e-c40a6e32efa8">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7328be06-f88a-4af5-b508-aac718f50468">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a7afab62-11ab-4cc7-83ed-1a12e24b2923">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2c4793bb-a68b-459f-ac04-a88f22820569">Unique Contrast Balance</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_aaa83343-4e3e-4139-a081-aa8fd690035b">(2001,xx15)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_55de7f72-6647-4beb-8b88-6a73017bdcc6">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_93431a58-3386-423a-82f8-0e751d83414c">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_03fc3915-13b6-4f74-a575-027ed60f77ff">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_aef16412-91fa-46cf-9e20-b1296ef84083">Unique Center Density</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9a2ba809-41ee-44c7-9ae6-16d513717759">(2001,xx16)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c397eee5-6440-475b-98ce-ca6e85c10514">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_091b9115-8eeb-4ee2-9cd0-0c4add476b4f">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ef9fd9af-076a-4a25-abf8-5739f84364be">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_185614fa-8335-45aa-801b-271f4e6228ce">Unique Bright Density</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a438ab47-adb9-4f54-b6c5-9bd855f6095c">(2001,xx17)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_da222d5f-36ee-4935-a610-c9814d7dfb41">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4d1b0cdd-a0c0-453a-b729-f78f1e57c2ee">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7612168b-b3cb-47c7-8d61-de044a3c8288">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d436c76f-82f4-4106-881c-ff312a983bd0">Unique Detail Contrast</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_dd16ae79-43af-4e3d-b723-ecc5ede027fc">(2001,xx18)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_93e22dbb-7ca7-47d9-a61c-05dcbadf0dc4">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d6d83653-6f55-4748-bcc7-4ec20296726b">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_605700b2-0b80-46a4-b285-951483149e44">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3a6d5e4a-66c0-4ad7-9979-f0fdecac45ef">Unique Density Curve</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_83b175d6-46c1-4aef-9a10-cb1e726d24e6">(2001,xx19)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_438849c6-db6d-4d4f-a09c-dbeb73aa88a2">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4a1e269d-260b-4290-9daa-2d95229dc638">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_10476a1a-f1bd-4371-9f07-6a6bedf47eca">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8b63ba41-3767-4c75-ab66-23fdfd539e44">Unique Density Min</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7ab9e9ad-a14c-45eb-b179-1e217b0e0900">(2001,xx1a)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_479451c0-4c14-4e49-b72f-171b341d86d7">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_72f88ef1-3489-4530-b255-b1b10381c05f">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c3ce29a1-75eb-472a-a408-949c7e22465b">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_49f085f9-d3ea-4064-8358-743031b43adc">Unique Density Max</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_dd22b84e-79a1-4c8f-8345-fbc0231aedd8">(2001,xx1b)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3a838305-4bff-44b8-992d-ad0d0ff10e5e">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_df1e8daa-28ab-4f5a-83f8-5383cf63bd6c">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d21d5ddc-ae3d-4e96-821d-ffba440ae4f6">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6a122832-a07b-4497-8ecb-6d2a7384d8b1">Unique Gamma</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1ced0142-2eb0-4edb-8ec8-773dd7b6c286">(2001,xx1c)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f30c4db3-54ac-41c4-8531-d6a0e83a3db3">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_09a5c43b-b25a-4554-8755-0179dd796588">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a982e4c5-b34e-4030-abf4-b1c4909692db">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2a6a1035-6fa7-4e3c-804a-00e61f4e24d6">Unique Gamma Min</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a51a0bd7-b7d6-468a-9fd0-5c74e1ec66e0">(2001,xx1d)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_eb0a9b60-ed26-4262-978c-4c09f3ea297c">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_296299a9-57f2-4275-9ddc-44a155da9ce6">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c7b9035b-b161-4794-b56b-1ad5518e8383">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_12f7b441-2420-4819-9170-fd684c7325f3">Unique Gamma Max</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7cf9d191-8344-4224-b55a-5c2b9ca38d91">(2001,xx1e)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2911fd49-cff3-4183-ac30-36523ee07841">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_98bdb4ba-3de8-4066-972d-791461d74ed7">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ecb8069b-ef40-4b9d-a3c9-4860c52df62e">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8702ade5-cae0-4135-a4cd-579997117a9b">Unique Structure Preference</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d0826653-bf51-47b5-a006-6bf97eeeaf41">(2001,xx1f)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_5cae7145-ce71-4797-9535-c832e8ba9f3b">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9f6d6e83-e567-4367-9072-aef8acaa4e22">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_82dd5ceb-43a6-47b1-836c-25b530d08492">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4551e99b-2f26-4366-bf8a-699eccbf38e6">Unique Noise Limit</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1dc2980a-840b-4556-81ae-57b5f60413f0">(2001,xx20)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f3e2fb0b-48e7-4e46-bd9f-08404a5611f0">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_badbe046-329b-454d-aa10-d504f545848d">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d7ff3e95-8e05-4dad-a4d5-68befa322c20">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c02ac5bd-882a-4f7f-b534-c653ca6aa049">Unique Noise Band</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b2dea354-8a3b-4cb4-b5d8-ec7073ebaa6e">(2001,xx21)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2708bbe9-f4a6-4608-a7da-ca9ecd8b3c07">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2801c791-a6f8-45a0-bfe9-2275f10e1540">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_87b736e8-00bc-4b83-ba28-7a7d4982e639">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_992d3559-421f-4200-a147-1fbf10c1019b">Unique Noise Step</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_735c9c49-0d4b-424d-8bdb-0478cd6abc4c">(2001,xx22)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2fa9a36e-9b73-4629-b4ef-ab2df6241b75">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_bdbb6ae7-2a59-4172-b1fe-f5d8dcea36f7">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f781b8a5-beea-4910-846a-473472c3e604">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d7824f0b-97b9-4eb5-8b4b-f4c94dce19ac">Unique Noise Compensation</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_82fa4d70-81df-4434-b7a6-352744ac1ac3">(2001,xx23)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4a88854a-e5b4-4d74-bc86-326d9888699c">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0682cc64-ce48-4935-8023-e0f2936253f7">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cb6fb45c-533e-488b-88b9-ca26bca8ca82">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ed015a63-b11e-492f-8112-2dd9bd3891d5">Unique Structure Boost</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d56681c3-cf94-4efe-8e8d-d6af5da0f88f">(2001,xx24)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4a7841b2-ce2d-4caa-8f02-69ccd0066547">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_000257e8-e3bb-4480-a752-02987359ab1f">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_39b04462-33c7-424a-8eed-794384d7ec40">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_750474a8-29c3-4b42-ab68-2584dacdc1fb">Unique Strong Contrast Limit</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c3ba074d-6c93-4e82-bdf7-6df3f5401eec">(2001,xx25)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f221bf06-0dd2-4031-9134-484befbcc1da">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_fe61410c-cc0c-4032-be13-ba43b2eeea85">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2a3a6993-7a1a-4d2c-ae7d-3fee7d80fa2c">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4649857c-ddd4-4517-a008-823ec6899234">Unique Strong Contrast Factor</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b8acd093-786f-470f-9535-5b2981239353">(2001,xx26)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_9f547aef-286c-4a09-a02f-963341ccd50c">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1e6cbece-fe78-410e-8b9c-c883accdf23f">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9302b5e2-e1a3-4b9a-ae96-ec1f3a13fbc7">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c54aad14-1784-471b-8f76-d9b102718dea">Unique Structure Boost Offset</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8e008456-da88-4875-87bb-1e9b7540547d">(2001,xx27)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3874aaec-7d79-4ecc-94d2-ea0b05bda7ab">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_be8aa0fd-8484-4685-9a96-21e65c224d7c">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_18c371b6-105d-4afc-b9ed-76f5cce2f95c">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c269f997-e110-4186-9794-b5784253d1e3">Unique Weak Contrast Limit</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_358d37a5-53ef-469b-9389-f31d6f1b444c">(2001,xx28)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1971f92b-efad-4c86-bd40-f93d379531b7">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6b17bee0-16b5-4500-9d1a-374dca2ff0d7">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_51be0798-fda2-442d-af78-9e36ae92d4fa">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_66f9f2e7-fcf0-4022-8f20-bc8515397efc">Unique Smooth Gain</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_11d6a5f6-42b9-43dd-9387-bb6b9ebe8629">(2001,xx29)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d0f8fe64-16f3-4a51-814c-aad4c8df0e09">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_25e655ce-c4d9-4e49-b515-37287814fce5">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_800198cd-99bc-499b-b350-6e8863c7fa51">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8eb8bccd-99f6-4851-a874-884f081fd20a">Unique Level</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7a787104-f471-4065-920b-eb57fde4e48f">(2001,xx2a)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b7502e16-90cb-4087-b7d9-ba4489a10149">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c47364fc-f3e2-4115-979c-0ed096e52c41">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0d383e4e-e5ef-4738-b8d2-62021b269939">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d57b9f62-0826-4e72-9212-6fcad2089cf9">Unique Gain Up Single</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5ed017ab-67a4-418f-abbb-12c2c38f7d5c">(2001,xx2b)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e3707efe-af70-49e3-b303-169abbad05b6">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_13d3bda0-62bd-4065-864d-7661c171323a">SS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b432c722-1850-4182-a204-593f6441028f">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6c885c85-acd7-45ca-97dc-63cfe481a5d6">Unique Smh Limit One</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_86013353-ac65-4f20-8fdb-309712682f41">(2001,xx2c)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b8237b44-380c-4c33-ae77-d6de155bb477">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_285d86c6-9b15-46a6-b1fa-fa40c45268a6">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_fa2002de-b05f-4e0b-b569-284664abd9eb">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2ef355cc-2088-4870-b54c-09669e338ac9">Unique Film Density Min</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5944630d-745f-4875-bfba-b888dc87f55e">(2001,xx2d)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_682b8ee6-4c1c-4a19-813c-1dc8f37e606b">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_12ebd1dc-8219-46be-9bbc-0ed9f222c069">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4ebabc8d-0bdc-4258-8889-e3ee1dff7573">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_06876767-f8de-400b-ac88-2a4f1dea8cb4">Unique Film Density Max</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6749be4f-abd9-469a-82da-64f84d6058c8">(2001,xx2e)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_04d1c68f-f781-43a8-b6e6-c5c97189a0ce">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_33351ffd-8c0a-403c-94c5-7660d86dd0fd">SS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0559506a-4afb-4a6f-8be9-e30ec56f7a1d">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_5aefcdb6-5f0c-41f8-84ef-8c808547bd48">Unique Version</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_685326b0-d1ac-48c2-bd84-7f4bc7910989">(2001,xx2f)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_501c5d8d-02a0-4756-a4dc-0e267435013e">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_78312354-d024-463b-9843-7ad54f991580">SS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4cfa87c4-c9c8-4242-9a2f-714bc52d7a91">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_256d730b-7aa1-4195-b008-efba477aaf69">Ranger Version</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_73fb79f2-3e4c-4dc9-9a28-f75c0c1f44d1">(2001,xx30)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_212c6f69-03a8-4409-9058-aa5b0726743d">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_30dc5e02-6863-40ee-87e0-63d8be015ef7">SS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_851846d5-fc07-406d-8cae-00a01feaa06b">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1460de8c-0bfa-40fe-a17c-43e95b5e967a">Ranger Mode</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7eca0638-3bff-4f47-b42f-a777b0954707">(2001,xx31)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_548754f8-135e-4bce-b2b9-8c826999c95b">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6dfbdea1-99a4-45f8-b40d-cd2de6192440">SS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_adc80bc1-b8b7-48b1-941a-02997e539571">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_241bd4f5-9fb3-4e44-930e-ddeef57465ba">Ranger Field1</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_808609e8-9a85-492b-bf4f-c0705cdffc9c">(2001,xx32)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a57e8fa5-c888-4989-a064-77f96dcd47a4">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_492069dc-1b6b-4144-9948-112e903add7b">SS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c47f3ef4-7823-467e-afc8-5858287699b5">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_bfe03fad-ad27-477f-a98f-dc40c286c347">Ranger Field2</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2c81066d-a9e6-429a-af0f-91683e114c4f">(2001,xx33)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e66b5719-8dcd-43ff-ab72-6ea5ef62366e">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_da2e2358-7d79-4ee8-b961-bf0746793ac8">SS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_16a2bca2-ac7f-4893-bd63-33180cbd274e">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a7902976-92b7-4e5b-8f01-fae35304795f">Ranger Percentile Key1</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a8721137-cab4-4c29-a68b-fbca556b518c">(2001,xx34)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3384ba03-3c45-4e94-8c37-aed1368c63ab">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_05d8ac49-f558-4165-8af6-35a20869a0a4">SS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9b9041df-0e24-40da-a506-1722bf45ac74">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f2b054c9-7bcd-4fab-b355-d98dfee5f6e4">Ranger Percentile Key2</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3340edb7-d7b2-4f4e-a518-45b3c8f9ba30">(2001,xx35)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_28764059-5f88-4ec5-b7c2-c4f428c34c1c">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_62b15817-f4fa-4f27-88da-14402e80afff">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_94daf43c-910a-40a9-a065-bbc4a8c54d79">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7533560c-ff40-40de-b6e9-076dfe2351a3">Ranger Dose1</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_008575ce-b8af-4cec-bd8a-18123e2fcc48">(2001,xx36)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e970e9a2-6a06-4082-9831-0f3faf0d4806">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1950ac3d-f3fb-4367-afa6-42c503ca96cc">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_bedeac62-5d45-49f4-bfd0-46a48f8afce2">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c9f4b3ec-13af-4bba-a60f-1b719b3db2f7">Ranger Dose2</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_234aec43-9bd1-48ac-a235-55c819e2afba">(2001,xx37)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e9912c9f-c69c-4fbb-9cf3-438707293156">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1876d012-526b-43fe-a572-c28ee8cfb3d6">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_fb6b6ee5-3df1-4064-ab4d-c7e1a3b37863">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a383c1a3-9303-4bb8-b240-baeac397414a">Ranger Manual Dose1</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4e4fec35-5585-44a9-a331-205848abf20d">(2001,xx38)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8ed1d81f-be89-4227-b356-3db01fd3997b">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_615d9af1-4450-4621-b06e-ef2be4ac985c">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ffaa93b9-fe3d-48da-aaa3-c768e9b87d71">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_24be64b5-ba05-4ab9-8cea-02630116a549">Ranger Manual Dose2</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9aab962e-79a6-496e-9b03-bc2465c88b25">(2001,xx39)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_88f5135c-6807-4484-b916-bfa99df26f02">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_524e6325-872a-4d62-a627-e1eabfe68883">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_16f7c203-a0c3-402d-9078-b2fb45ce288d">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_0ea91247-6f76-44b6-b5a2-f8a5f7c1ea91">Unique Rox Shape</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_759124ef-e071-41d9-ab0a-b46b6b0d595d">(2001,xx3a)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7f117138-193d-4a80-8d47-884a163838a7">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f08f53ea-8e68-4f9c-bc72-d006a74440a4">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_94d61953-6153-4e30-be0c-28c3e60c01d8">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b90201b8-e6e1-4176-af73-2b8eef23dcac">Ranger Set Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d3c770e0-a0a2-4824-9a6f-5017c117559e">(2001,xx3b)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b21c4859-c2b3-43c8-93c9-2f2404009c61">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_746d615f-326d-44d6-82ad-1269b8a5aae3">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_77708b38-ac7d-492f-8d65-3befb5d8792f">0-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_94a73961-1d05-4be6-a53b-d531a240706b">Rox Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9e963717-f20e-4ed8-913a-a18c7b030164">(2001,xx3c)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_eb99ff5f-309f-4250-9e3b-ece386a8f452">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e477c248-cb57-47e3-a2de-95b1bf5fe656">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_70320636-bdfb-4f6d-8f0b-e3214b982a33">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_0dac8b33-1288-4563-a524-878bdb697afa">Xray Edge Enhancement Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_90bde2e3-8401-4c57-b1ac-4b5f6f880aed">(2001,xx3d)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4db7a4a2-bcb4-44ab-97ca-f6ac1b067903">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8260d2b8-be34-4d31-99a3-fca9746f2c05">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_52df92b8-d20e-4ff0-9111-aeb35c5e294a">0-1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_82b638cb-c566-42b4-80c9-dd13561bb813">Edr Lut Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_64667a43-cf4f-4ca6-be25-41d9bf481528">(2001,xx3e)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_5d8c2d44-7c3d-4427-816c-bfadc4c2d892">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7d02d250-29ed-4af1-a8b2-353543127ad1">SS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_363c4382-6bd5-46e3-a379-14c37e304767">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_21005f88-6e33-4d57-9cc5-29b4da6370e0">Unique Dose Decades</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5bc56bdf-b9b9-434b-ae7c-131cd0f91ed4">(2001,xx3f)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_deb0c5c0-f017-436e-95d6-2b8725249d64">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_162adcd1-9eb9-40b1-851c-6eab7abe1bd9">SS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a36a6194-b705-45e7-8b14-6b947dde56b4">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_0a3e9555-fb04-4907-a15f-a324f083cb76">Unique Dose Unit</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8f071c7c-dbff-47c2-b8d0-68e91057cfb8">(2001,xx40)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8f841ad8-6db9-4478-877e-dd398ac28d86">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_aa9ec754-02bb-4b2c-b533-ceafc18325b8">SS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d4bef8a0-e5d2-4843-91f8-9c358e7c1260">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_35464376-f3de-4e47-9cb9-cb29fb4f5f21">Unique Density Unit</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4b89faf9-36a8-4736-8df0-fabbbe166c8f">(2001,xx50)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_0fda53c9-2a7c-4af0-954c-cbe0e36436b9">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_eadc6e9d-ea36-44f3-a7b2-1835292d813d">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c0e1b8d7-04f8-4788-be37-b22ed79ea2a2">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f7a6f443-7e0e-4b01-bf1a-9d351be7bf15">Workflow Status</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_28a8eba6-a3da-4866-8399-578e19a65615">(2001,xx52)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c0b7e6c6-2500-4149-9ba8-51952556b1f2">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f28e9c54-24e8-4ce3-bd63-67cea2713481">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_13c4785d-b4ef-4f5f-a50e-6c61044188d5">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_bd5b708f-bf6d-4d7c-91fe-59006ae814b4">Workflow Step Id</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_63207540-b13c-4002-9112-fe3ac5d00954">(2001,xx53)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1dab9ac3-b774-4182-88c1-8af6c91bc7b6">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_acb837d0-0f92-44cd-938a-c2b9cdcfb308">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ce14fcdb-6b60-4607-af7a-22e74160aa9b">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1a77a931-c5c3-4d45-b668-26803bc7813b">Workflow Step Status</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f131da93-d569-4924-98c9-b3150b5b659e">(2001,xx57)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_35b8ca9c-0537-4339-b5f1-3190eac37c34">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2c60a958-595d-42e8-ad6e-67b19e5d0683">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_026bfa26-7115-4067-a075-8ffbdb02aec2">0-1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1feab576-a3bb-4d10-817b-c23c2d3f0739">Workflow Step Input Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_46b76d4e-c873-4487-b6d8-67a5917186af">(2001,xx58)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4282a09c-78a8-4d45-9a01-16981200cfd1">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d9e7df4c-a279-463b-9ac0-7d33a481ba0f">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_19bbe88d-7c3d-497f-95ce-b1101ab5cfa8">0-1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d1eeb913-cb7b-495f-9efd-64d94178913a">Workflow Step Output Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_52eec8eb-fa5c-4111-8a6e-574c1ec07795">(2001,xx5a)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1f0c4713-679a-4f70-a205-4869f68534f1">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_aab67087-a920-4523-a4fc-988b7fa5bbb8">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9098f323-80b4-4875-b900-80a9bf6925f8">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b9af3f13-f830-48a6-a8fa-79fc00e2e95e">Workflow Step Type</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_78457ca6-849f-4f0b-8452-a0499b166c07">(2001,xx5c)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d31b5e8d-ff5f-4e44-978e-6f42479cc442">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_05be740e-0343-40a5-b9d4-f8f4ec28f686">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1188ca0a-d0ac-4ac7-ae25-abe3113372fd">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e1f00566-8e07-41f7-a53b-c9f5945bfff5">Workflow Id</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1bbf7479-2d67-40b7-a5d5-d286d733ffca">(2001,xx5d)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e65d33aa-d143-4b4e-804a-a2e331b150d5">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_659a0b01-f2b8-49a6-b20f-5e9b5b3da99b">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5be68fc0-7a21-432b-80b2-7a40a86e2b28">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_542e6383-8043-4729-81ed-9426d77e0c0d">Pixel Data Representation Rows</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9a2fce69-2072-49a3-9f83-841897d564a2">(2001,xx5e)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_dbb9b48a-fad5-451b-97e7-12821b01516c">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_bd4d86dc-7e87-43e5-9958-acf30c730c2a">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6daf43a8-8a63-43a9-adef-b6e5d4a681c4">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3e539cd1-165e-4098-acec-4a3aa7640979">Pixel Data Representation Columns</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_630939db-05a7-4050-b306-74fd38e269e1">(2001,xx5f)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_253477d7-0a02-4b52-a2b2-c7e7f7e5800a">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b8ef3bd7-0884-46bb-abea-2806c6f0e550">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_bb2cf351-9a72-4283-8c2f-826a05ddb8f6">0-1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6a4d0117-35eb-4458-957b-31bae247ecf6">Private Dicom Extension Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f953e3d7-2c95-4afb-a272-815a2a2c1ba1">(2001,xx63)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_aa3c786b-8815-4d60-9b1f-6419770334e0">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2d67e28a-21d3-4821-ad8c-c9d359628c9e">ST</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_eb85f8ea-4690-48f7-bd9e-872252d9bf2f">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_634cc5b6-2132-443e-aef9-b76e3c46097f">Isyntax Reference</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3a1cba3f-b3b6-4e83-ba65-7856cc7e5206">(2001,xx64)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_fef4c466-78f9-488f-b4f8-e980fdb67166">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_db4ac97b-2da1-49e9-afc1-89e8556857fe">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_424efa08-fb29-4004-b7be-9719e3cf3c5e">0-1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f8654fce-77eb-49de-b0cc-074e549f709c">Workflow Step Job Params Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_79ca8d24-67eb-4cab-a49f-0d781a44d5c6">(2001,xx65)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ade2f43c-e138-40fb-a195-f2e6b919d738">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_81a2cdd6-42b2-4db5-a925-55d13f92f103">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6e917c9e-4b7f-4c3a-a84b-b6d9a43da514">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_81ae15f8-e34f-4bce-b194-7cf1b318e858">Preserve Aspect</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ac5dfdd6-0aa8-46cc-872f-9f9aaf0e65be">(2001,xx66)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d43a5f52-3db6-4a2b-a069-ef7e8ef81dc0">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f1fb0268-c629-4db3-8e92-ea6e8d7c84be">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0089806e-4a71-4da9-94dc-9f059aa37629">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_34e648c1-8097-4c55-87cf-8548c42c78ea">Interpolated</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3e0630fa-9ad3-430c-b9b0-96198464eab4">(2001,xx67)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6b325f43-7870-424e-80d4-2e2ddec00906">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ea3597a5-3a6b-4cda-a676-c3fe7c9308ca">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f610506a-6aae-4e26-be4e-605e768018b0">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_0e98a4d3-6315-4092-aa4d-bd8cda6090af">Error Flag</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ec679a43-0360-41a9-a1e4-b7df4d64a1a1">(2001,xx68)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_54aa2171-aaf0-46aa-900f-aa499b913663">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5e2c92c3-292e-47d0-92d1-ed048f4d1afb">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1f7791a4-1b24-4295-8488-40aa8147fa9c">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_971b37c2-baae-4fde-87d8-e63bbe95bd9b">Error Message Id</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0094c7d7-82bf-4ee1-ad5f-56bdbd39f938">(2001,xx6b)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_fcfaed04-9d9c-402a-828d-f4a97edac590">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_40e4b3a7-5e77-4262-aa96-1a0b02a56ffa">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_fa3e5b60-8a2c-44f0-aee4-0141eeff4d3e">0-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_07d45e40-595d-4f3e-9f4b-d71b234a3135">Suitable For</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f3f7fa2b-ee69-42e5-9f88-8c6b61dea924">(2001,xx71)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_15dadcc5-2c8f-4b5f-82d0-01b0f6be9495">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_fd470ae2-8ac7-4487-9636-2b0c27e5be0e">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d34b73a1-bd52-4e3e-89d1-797c4c4e574f">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_0b03b9d9-55d0-4604-8bd3-6e09f7e4c1af">Submit Mpps Job</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d7f50ecc-b686-4d88-803f-6f3baf15cdd9">(2001,xx72)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2f6e02a3-0d26-4179-a311-41e930d23878">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_52b7a921-6d77-403a-9919-32bc3e26ca93">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_aab60a21-29a3-4a9a-ae59-eb7a5a6285e9">2</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4ed70e7e-5805-4b29-a94e-ab0d2c757ef9">Displayed Area Bottom Right Hand Corner Fraction</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3286b14b-3582-4373-b215-f9e9d93d2e83">(2001,xx73)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7b831316-e699-498b-9d9e-6705bac1d2d7">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_bcafd3b8-032d-427d-95b0-777d0e8d516b">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ebccdc87-4386-49e8-bf1c-92c9bdc7cca2">2</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7065b33d-35a6-4716-88c6-e3f0202ac718">Displayed Area Top Left Hand Corner Fraction</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e052c383-dcc2-4727-a584-5844d411a815">(2001,xx74)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_90d313e8-9794-4536-9d56-f444bffc9fd4">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b895ee8d-cb9d-408b-b8b4-a1add998684c">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1c502704-1467-41af-84c9-c1bd64b9e280">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_39e02b13-3357-4e20-887f-6d8520f6fea2">Interpolation Mode</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_fb076378-52a9-4fc8-bfe4-e66de376020e">(2001,xx75)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_41e0b10e-a3b9-4eb0-a731-240d8ed332a1">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a90bed74-7375-4554-a967-306cc57429d9">SS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_faeca96e-fbd1-4a21-b2fb-0fb8085e2790">0-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e305bb06-b975-4a1d-9192-dca91da7c690">Graphic Annotation Id Reference</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_de3cb8fc-fd00-48e3-a391-2594486475d1">(2001,xx01)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7debed91-48bb-4029-94c0-396d3939c8b5">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3b47a478-2e70-4e7f-b9fe-90c60e33d548">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4e472ff9-277e-4789-adcf-b0d81662a092">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b12159f3-41f7-433b-bc37-3c4c25505081">View Geometry</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6cb5f906-4676-416e-9309-2aa3b8fd0652">(2001,xx02)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a2a0a955-5722-4316-8aa1-de1375384816">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e5f454f1-c5fd-4fcc-85af-1f2a4a9393ae">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_33ad95cc-89d4-44e5-ad40-e39abbb1e70d">3</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_75c853b4-468b-4939-a64a-ac3d650621d5">Frame Geometry Origin</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8f904a1a-0954-4e49-8de2-27f518620b8e">(2001,xx03)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_704aca43-d62c-4024-8076-17b702d0ffdf">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7d1fc85d-0b8e-4542-b79e-149ca43d4148">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b5af6a74-5cfb-4807-a3e2-ed23d52ebf80">2</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_0d75a116-1e5c-478b-8f13-eb2056edc218">Frame Geometry Extent</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3faa4a1c-a8ef-4435-aa12-6ac52a2adede">(2001,xx04)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c7045521-496e-4e26-b63d-52249f92ed87">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a3c7a07b-e22b-4408-865b-ba19c6810320">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_60668fed-3567-44d6-ac63-b13708f5764e">6</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c8960712-287a-4230-99dd-b839d18f7b62">Frame Geometry Orientation</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0d2c10c6-cb50-4755-880c-9545253cf460">(2001,xx05)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_489fdde5-2e41-4483-b0f3-dbd8d7ea8016">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_824760df-e70a-4903-b748-1b52c2d62e49">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_26411627-1afe-40b2-8ebb-8fab4b41e254">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_13b1170e-7cea-4dd7-98f0-da46240215d1">Visual Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4b65b3d6-c147-4a0a-a8d3-2e634cd30bb9">(2001,xx06)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_390542d1-7843-4b65-98db-7321725d5263">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8e6e8ded-87e3-4a30-86bb-09e45c540659">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0ac54056-dacf-436f-8a4c-962e77f9efb3">0-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3dd4153a-ce04-4fe4-9c6d-ecc799b19e5c">Cut Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0fffb87f-17a1-4dc7-beb2-f0485d92f418">(2001,xx07)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_56be396a-0bc2-4446-b42c-383904902a4f">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_13559a04-f0bd-462c-b77b-d1bb0265ae09">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d81f9a50-33ba-4da6-a533-5c2d83ab431d">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_0605e8ee-0e21-477e-917f-436fe3f51d1f">Visual Opacity</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_94f60509-a0cb-46d3-9654-2f294f5f7eb4">(2001,xx08)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_56431bf2-71cc-45d1-ab20-a2f14f641b33">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_18a518ad-2ee8-43c4-a726-d1f74581fd00">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_36a19f3d-98a2-4c01-a78a-ff21e10181fe">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ff0eedce-97c7-4346-ac87-7918d511756b">Opacity Map Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_13d95293-a4cd-4420-8333-52faa048a85d">(2001,xx0a)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c05c5018-f511-47d7-9108-28a0c9f90908">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_106674ed-2330-4452-9dbb-1b6c55d938d4">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e9f01660-3c9e-48e4-92a8-1d278345c870">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d191cb5d-9aef-4378-9fd7-80e789313428">Light Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a81b22e0-ebb5-4d18-ac15-0b468e4ce58b">(2001,xx0b)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7a36c0c9-e445-4f0e-8306-ea6be3be4a87">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_be8b92ea-4c0d-4d7d-b1bc-22e702e058ea">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_013f4ea8-519a-430d-bf39-3b1b3bd95188">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3db18f39-c2d7-4330-b171-d366fca52e8b">Color Map Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4fda1d48-66a4-4399-85a2-01c2748d3dc4">(2001,xx0d)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_09214936-8df1-4b6e-b492-ad6a5c5c495a">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4ef63568-c850-4bf0-a82c-4d714ff2fae1">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cb4c405a-15fc-4e1f-af38-37deeb489122">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1afce9de-f352-4c48-a968-f56262913e06">Visual Threshold</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_fc6ddd8f-94ac-439d-8bdc-83bdb50904a4">(2001,xx0e)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ef5d888f-db21-468a-8236-cce053e54087">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c908e43a-3bb1-490b-8de7-19be07b8f6da">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d16b60ae-a932-4ed8-b3ee-f2a3b4ead526">0-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_17630a5b-a1fb-453a-b3f5-dc1502972e05">Scene Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5997e1da-cf29-413b-9662-a7763cb354b1">(2001,xx0f)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_cdd3a5e8-0365-4744-8ce8-9f33cfffab63">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5927ea7e-f395-4490-acb4-372c7ee0e8cc">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_01a93538-a28b-4fe0-a4cd-6234575e870c">2</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_324c2e88-6b29-43fc-b932-ae984f1f5185">Frame Geometry Slab</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a52104b0-739a-447c-9029-7de447b3a082">(2001,xx12)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_61a8dbb7-8ff1-49a9-948d-c19e38688e00">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_693b3a2c-8e7c-421a-b894-c0b1237bceb1">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ef15257e-c170-409c-9202-f63616b74572">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_631c6993-1008-4d7e-9583-42cd7b65c6a1">Gradient Map Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_806cba7c-5f67-4d9a-b5b6-fe4d8423c0e9">(2001,xx17)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d59c08e7-db83-4e5a-80e3-d464601ae096">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7e7e0117-fb82-479f-94a1-8d76b2cb789f">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_706f68e8-2d9c-4223-acd2-2dfc56470655">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_fef2828f-3ee5-4363-8c46-a61106bc9a9a">Display Rows</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b98b1b76-f56c-49d5-9819-7de2d2191618">(2001,xx18)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_45207244-21da-4732-93ed-fd5b6854b8a3">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3c021433-993e-4059-9581-9c6d921a5ee0">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ee6d32af-8a20-4fc7-8d10-daaae6a6725d">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f7ea769f-4c0d-40dd-be80-947daba634f9">Display Columns</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4e2c1002-695e-43e0-9972-87a36479ffe5">(2001,xx19)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3c3c5652-89d1-4b6e-99f7-cdc2c4071eda">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2566fe02-2bbf-44aa-8a79-8f32d30fef46">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cebee348-7105-44e5-b5a1-37d5e9ad9b96">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_65b1e40a-817c-4cc2-b6dd-1456fab8e333">Frame Geometry Type</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1271d673-dc47-4824-917e-708f17b7dc4f">(2001,xx1a)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_76e0a12f-15d5-4b63-b467-28c1bd7b977b">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_69ec35dc-6595-4571-8434-787ed03ffb01">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c1d3317a-5086-41b1-8a5b-239b7a6052d5">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e209aba7-909c-4d42-aed0-3699bccef0d4">Light Intensity</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e7c2811c-11c7-438b-b515-d722846260fc">(2001,xx1b)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_34d56a09-7ae6-4937-b92e-75cc255c3bd9">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_367db7d5-3864-4b2f-a14f-616130831356">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f40afbbe-f351-4f3c-957e-92e85c79fd0a">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d0eda45b-8b2f-42fe-97f6-ac01b08c86b1">Light Color</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_be2348cd-9f49-44b1-b259-03d856d31700">(2001,xx1c)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_192a89b5-ffea-4c49-b664-32ebda0ef96a">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2f8f4f90-3a23-4497-b1b0-4e10fa47b39f">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a7db4178-91a9-4010-8b5f-983760f198f2">3</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4561a89f-838f-491a-9f9e-3fa8da67b43a">Light Origin</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e8ad6433-3ec8-4512-98f9-1522b752d2ca">(2001,xx1d)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2add8c6d-fc32-4d9e-b1cb-921a16165b9e">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0d4f5ea3-b047-4115-ab9a-663f6b90c6b8">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_76fb9e50-9cbb-4312-b75c-696ce6b5c5d9">3</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_9165124b-ece2-47bb-a0c9-f24590c974a5">Light Direction</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4e540a84-e77e-4675-9cf0-7d270b6cc327">(2001,xx1e)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_525b7146-bac9-4416-af29-204297f4dc6b">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_144dd8e6-e19e-4724-9a52-ff1109c19f86">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_383bd132-7ce6-4029-b587-e4d19de1a6b8">4-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ce107437-1b0b-4941-b214-394c268d8ee8">Color Map Samples</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b63996ac-1358-4868-b11d-13a34560dff6">(2001,xx1f)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_80bf9ef6-fa50-4b82-8122-5d8e60976b3c">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_82bc035c-0f2a-454a-b698-232c2b1f2a17">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_71c8cfd7-82ae-46ba-9aeb-722795d324dd">2-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c73d07f6-7897-4772-980e-03d4a99a456b">Opacity Map Samples</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_69a24f09-8908-4401-820a-38400680694a">(2001,xx21)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_77170981-02f6-4b05-848f-a8e44d0c21f2">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1e95a7f2-22d4-4a69-aaf7-8aed17169451">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9a24a725-82ec-40b7-8385-20bf2608ab12">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_cf171915-a93b-4e77-b854-15e18be3f808">Visual Color</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_02346d59-6b46-4ef1-9049-c081801a76e5">(2001,xx22)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_14190bd2-1bd4-4c12-8348-ac21c5f54db8">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_807c1515-f7b3-4ba1-9038-39823d6d4559">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_45356633-5980-4754-85d3-ca665d562c06">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_93cbfeae-6788-4df4-b529-5a365a2f835a">Illumination Ambient</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_877a8ff2-8ff0-4dc3-be94-22b720bb7ed1">(2001,xx23)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_fd939815-0ce9-4f3e-b8ca-274d08cd6dbb">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9b04604f-af30-4700-9f59-a82950d76e76">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2d8a8685-1f4c-4964-87e1-fd93eda2c862">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e05ae470-0cf6-4b5b-991f-d60ecd70ad1a">Illumination Diffuse</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c050ce19-007e-42a1-a25b-817285d1bbf4">(2001,xx24)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7474399b-bf22-48fd-afff-dbefaa907d6f">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f21a37bf-8ef8-4d86-872c-1765d0422712">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d8287257-2427-4144-a220-6037510dfdab">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ae3a2e9f-6aa6-4c7c-9d5d-71ce6aba500e">Illumination Specular</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_bf910a75-c21c-451b-a3d5-c3e1d47a673e">(2001,xx25)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ad2ef656-2b5e-4547-a404-afe89efa9be9">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1e6e7002-af69-43dc-aebb-509dd55e6991">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ec207135-2c3b-4ad0-8536-68f25c44bf9a">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_22d47395-ffcd-4629-8fca-09729255d53b">Illumination Specular Power</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2302d18f-5a58-4813-9323-fded7ed94767">(2001,xx26)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_5e60a116-4f1a-4f2e-a745-dd4b29b35261">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6efe26ae-2318-46f7-93da-313eaa7b474b">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_17949d64-e8bd-4c09-888f-c56574299587">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_38c15868-e3b7-4b60-a3a9-eb3d3b7c346a">Depth Cue Begin</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1f707147-8991-4755-8b42-ea70a95225ea">(2001,xx27)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_73960ab9-f290-442a-8253-3ec4b5267961">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_bc262201-7e19-441c-b630-a1a50dbc5df7">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0259f164-fe3b-47c2-b754-bd527529fc0e">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7db53c48-b606-45dc-aa0b-a4f0d8ea73ff">Depth Cue Lambda</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5ffee340-fd59-490e-87bd-f4d7c60cfa5e">(2001,xx28)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d11eb545-f7cd-467a-8d8f-2b2e51e7e6f9">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0a7bee53-1480-4d66-a65d-52798a48f8ce">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_99c8edc1-af2a-43dc-8692-e6a3c8bc540b">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8bd26ce9-8283-4295-9da2-719ffc8ed2de">Depth Cue Function</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8c3f0fa1-282b-49dd-b40d-ad8c0317d491">(2001,xx2a)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c817a306-88c4-4d26-9608-415065018d6b">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_032c8493-0b80-457c-9036-d30797fa527a">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_bb1941a1-86d3-497a-b018-bb5fbc668bc9">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_68c6c26b-5809-468a-ab25-a6ed6fa869fb">Cut Set Type</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1cd9f0ed-219e-4750-9a61-b24486050d19">(2001,xx2b)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b0632f0e-186d-4a99-b7c4-7cc9f0ac2b41">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_69319516-2f05-4da4-9774-aafa9e97889b">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_97efb87d-f1ce-485d-893c-056e03aa3d1b">3</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_72f20216-7651-4e1f-9820-e15e55cf13dc">Cut Plane Origin</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4a97e808-c041-4811-80d0-509d3df1fc69">(2001,xx2c)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_52d9b752-5ddc-4e99-8710-48ea53bd1517">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_94f58229-38c1-4dd2-b4b9-b2bf6ad56e9b">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6bcc4843-4dfa-4d70-a4c5-aeef1519044a">3</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2499042c-2c70-4cec-b1b8-3b83b076698f">Cut Plane Normal</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3c57f2ce-7d65-46de-89ef-896aa1ec6c70">(2001,xx2d)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c8d60c66-bce3-4154-b9b8-bb8e30172c57">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e10913bd-cf55-4577-b6d7-3fe131d18207">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5bfee049-85da-445f-b1d7-e845637ae1fd">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_43a96486-a948-40bc-ad21-941c84681b17">Volume Definition Number</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a855f353-ba75-41b4-a999-e4a3b6b9f927">(2001,xx2e)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f407543b-313d-4f76-97e5-b9897077d203">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_472688ed-4615-4da0-96d3-ab207c3977df">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2dbb46c9-804f-45ee-9d9a-195ddba736bf">0-1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6e8d16d3-bdf1-4705-987d-cf1779f07a65">Volume Mask Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ee32cd22-ef89-4a9b-b6e8-a76e20f13d84">(2001,xx2f)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_773e1f95-c7bf-47d0-a8fb-57e632dd90e3">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a639e6a4-c6a3-4885-ab88-087e72c4d5e8">OB</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_305ad3e1-b11d-4995-92e1-7735c2a2b4fb">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_0a9d424e-31d1-456b-9353-68577c6a8389">Volume Mask Data</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2f46a53a-feb0-4ba9-8c93-db74638cc646">(2001,xx30)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_5e5660d5-39d3-4204-9345-ab05150d1b7f">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8804e050-8195-4429-a45d-e98d2d4eb44c">SL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_15350b41-e2a3-47a7-ac0c-1a6be6208838">3</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_89cc3748-0646-4a85-92e6-8747a82c0191">Volume Mask Offset</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a99fce18-c2bf-4225-932e-f3a3ec70e86f">(2001,xx31)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_13fe0b28-22a2-40b5-b3ec-ec6f53cc5e21">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9aa7a99d-b08a-47d7-a039-805089288622">SL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_35030b42-3bca-41e9-ad7c-ba24d12ee76b">3</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_18c35f95-074a-4afb-8618-c6495f09299e">Volume Mask Size</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_88c08482-c88e-4e89-a81b-d9c3cd0ddf58">(2001,xx32)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_992ee079-16f4-4931-bec3-4012574db4e3">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b182a52a-01a5-4b4b-9e7e-b24689a88483">SL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_df2d9361-0b7b-4db6-a5bc-7fa655a538be">2</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4183246f-7112-435c-9f8c-b8103ab5228d">Volume Mask Alignment</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8999fdc6-2495-45fe-8a97-e08a3fb0283a">(2001,xx36)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b7e2f021-68ed-479e-980d-e6ddfaf2e3da">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_287da6f4-a37e-4e15-9f7f-95623253ee8d">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b3ffcee3-0512-44a9-832f-a814bb921678">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a4f23e02-112c-4aa7-95c1-87e643dceff0">Light Anchor</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5c143d10-be4a-44e4-821d-22c70a34ef77">(2001,xx37)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_90a1030e-be2d-4d6e-982b-a5d1c55ffd30">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f428df13-9ca7-4e32-81ee-a72eb54dd950">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3dfd483b-96b4-47ef-827a-a09893282de1">3</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2dbccea8-fce6-4034-8e25-69af39032eae">Cone Geometry Origin</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_addf4548-4331-4ad5-b541-9e8f005f625d">(2001,xx38)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_be2e5b22-e3eb-45dd-b43f-6ee289b873ea">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_70acd2c3-c065-40d2-8822-b5959c9567a0">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_fe570e85-5379-4ec3-a807-2e31f7b75932">9</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7ea5e04b-2b75-4553-b6b1-fc151055dbff">Cone Geometry Orientation</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a66be7a2-dfd4-4179-a2e7-dd19226ab1df">(2001,xx39)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e2aa69b7-8b94-49fc-a113-5bba2c030d70">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ec861703-81cf-4122-adcc-3447dc9b1c46">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_bc3ec5a9-43de-45c2-8c01-9cd954d7e97d">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b0ee868f-3b34-4878-b3c0-632c32b7b0ef">Cone Geometry View Distance</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_264f6990-3751-4c23-91ff-9522ca629b7c">(2001,xx3a)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_935449aa-fedc-4669-8be9-0577e3fd1bd7">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b8b5c358-7cb3-4691-a4ab-0bd25bc5ac08">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_22d5bf16-7368-45e3-a7ab-e360c4dd2798">2</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_031055ac-ccaf-4f86-97a7-b694917f5227">Cone Geometry Slab Extent</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0506eb97-544d-4866-b709-07177649d497">(2001,xx3b)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_5b1ed527-2be5-413c-99e2-d0b7482dc7a3">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1cb72866-df30-440a-9bff-c9e976c18c13">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c75fed9f-3841-487f-8ebb-1d55f671ccb5">2</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_9cc53537-1f66-45e3-88a7-2c325847843b">Cone Geometry Field Of View</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7d4d4ac3-4c02-4f67-9e92-f1b8eb9bd628">(2001,xx3c)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7f5cb970-f0e0-4787-b817-a675b00b240a">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_79c90e05-bb74-4030-a3b2-edeb31ea969b">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_09034458-5452-419d-97cf-7c7c8ad65e0f">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_30c63a2a-0443-4918-84c4-f30a8f66ab4e">Intensity Map Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0bf8b895-3909-44ab-aa58-6753e696be00">(2001,xx3d)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2fb9474e-da62-4e22-97fb-5450a944c515">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e95652aa-74c3-41b4-9f84-17f234ffd344">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6116e5a8-eac2-42f3-a2c8-3e5778f3fe8b">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e6f4bc83-93ae-447d-b382-5157877dc16c">Intensity Map Samples</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f0b0176e-d309-459d-af14-f6d283ced962">(2001,xx3e)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_cfa55fd6-0e4a-41da-99a0-18e54956f2a4">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b4fe8beb-0703-45cc-9037-9110e4c9f106">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4a6a4dc0-6162-4c5b-9719-4a13fde158b8">0-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_77b6be8b-10ce-4b1d-abb3-057cefc87151">Mesh Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4af01d1a-1c42-4f86-a310-416bc0dec323">(2001,xx40)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_bd0f5d0f-3a8d-47af-82f8-a2aa19448980">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9e62f0b0-4d0a-47e9-a929-3ac1673660ff">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0d0bac80-77f9-428d-832a-dbc62c4195e0">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_01e627c2-0b23-49e7-a8d5-eba894dfd648">Mesh Color</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0fe5ff59-f13b-4da6-ab12-4ce5eda05c11">(2001,xx41)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b8c08e54-0813-4174-8bd3-c4f99897bff9">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3295e7d0-33e9-4073-a31a-184ac5208d07">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_58bcff52-97b2-4bed-8c11-61000c71afff">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_775ab032-4358-4613-b143-64163c1fe319">Mesh Draw Style</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d67f5cad-ca81-41d2-b57f-73ec11b79731">(2001,xx42)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_76f7f83a-0bb5-40d1-9b63-b87816a936cb">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1adf4c5b-9e35-4d99-8d6d-b39ad9f5cbf3">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_76eee998-4707-45f8-a6ce-8d18c2e742f1">0-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c5cb16ae-05b2-42ce-a56c-1eb75dc414df">Mesh Section Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c59e5624-71af-4777-99d4-be45184261ce">(2001,xx44)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d967d7d3-2be3-4692-9f2d-f5bdade00c83">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1e68e8d5-cf87-4c88-a6d1-0656455c6da2">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_408591ea-a36f-4659-960b-33a2f74ead08">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b83a7d14-83d1-47c9-9eee-47d4d670934e">Mesh Section Vertex Connectivity</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_99fe1e79-b1b6-452b-bf09-992d64d47174">(2001,xx45)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_172d3683-9274-4143-8e0c-6815cb55066f">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b82fb44e-c968-4e2f-a3dc-7e99d3486285">SL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_74d299f6-9346-45d2-920a-612b4f75c74c">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_81626579-a5ae-4e34-b559-f3aa74ea7a6d">Mesh Section Vertex Size</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e95f7c6a-65b8-4f4d-85e1-fb07bb71cb56">(2001,xx46)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ede64168-d5ea-42cc-a641-5f5a5c524471">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2bd9e050-249a-4b21-bd82-430e24d08f98">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_644327a3-ade0-4b49-a52f-92e88e716a6f">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b1724c02-3e2a-42cd-b914-bfa38971a367">Mesh Section Vertex Format</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_94a777bc-4e6e-4f6c-9749-16011340a092">(2001,xx47)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_288765fb-b97f-437e-804c-10743720a675">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d6cd5e76-349c-4787-a169-c4821482641b">OB</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ecaecd89-e60e-472f-b607-24cc21108359">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_0df0b3d6-31c8-4153-ac82-a45d9dc4e490">Mesh Section Vertex Data</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a600c1eb-e9f1-42f0-8c90-09e747ad13c0">(2001,xx49)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d8625592-c30b-462f-a88a-c78032096276">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e436d7dc-cfce-45a3-800c-3dc3e3eb8e78">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_99d4be42-d9aa-48bd-934b-b158bdf4b4a3">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_58815a5b-f05a-44bc-a61b-b6dda6d29775">Referenced Volume Definition Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f8d23302-ef6e-432e-925b-21be687bd99e">(2001,xx4a)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_45672fc5-187c-4b20-a053-fbcaf263a24d">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7e656c88-f590-4f4e-b3e2-1da156043884">OB</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ebb60a39-ccd4-42b9-b9c0-478f30277adf">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_51009a91-04a8-419f-9311-9f08c2cd9704">Mesh Section Index Data</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7b561082-c7c5-489b-90b7-7ca45e7aaa11">(2001,xx4b)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_be9761c6-0b10-4887-93da-b6602ffbd71a">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6b4e9b19-78dc-49e0-983e-805a7b4d5e0e">SL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1350ff62-9355-4300-95e7-d13cefca985b">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_5c637034-e4e3-4455-a9a5-017962d07644">Mesh Section Index Size</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_104b17fc-cf1e-43cb-88dd-ef3671e15a8a">(2001,xx4c)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c2721347-96c7-447c-b1dc-a7a5916cdfec">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7e8e62fb-487d-4303-be2c-3d5452012c38">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2cde0b0e-71c3-43bc-a34b-3a1a478d1ac3">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c0017bc3-5d49-441b-bbab-5893f56d8c78">Shutter Interaction Type</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_050d98cc-0318-47b1-975a-e9b35c7589a4">(2001,xxa1)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_72c89f1a-b041-4be8-bff6-170ccb57e085">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_081981e7-6545-4c55-be65-1deae917d924">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_89d2a579-8521-4832-9ba1-532ed1ace058">1-2</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_523a4ef8-f3d0-4dbc-a90a-9fd6a21a9be7">Volume Type</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_730a256a-4614-45e1-bb21-595e2f1d2cd3">(2001,xxa2)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a978b54a-190a-40b8-bc43-952bbabbb1b7">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5801c625-0e79-4204-8d58-2b04521740c1">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ec7a73d2-01f0-41bb-8858-4160de8b23b2">3</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e9843f89-f106-4d5c-8fed-6a615cd25f21">Volume Origin</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8bcc8f47-2b7d-46a3-8f72-d355203deab9">(2001,xxa3)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_02919b70-5cce-4898-9699-f56cd3005da0">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c7239926-f32e-4772-959b-6b3923eb52cd">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c0c0bfad-1310-4151-866d-778888467cb3">9</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e992df97-0f39-4823-aef8-370cdf93ed83">Volume Axis</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3a7a0478-035e-4294-a1a1-d59e8ab85747">(2001,xxa4)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f888f26e-ace4-4511-9836-e18ad5259bc7">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_78cb9898-8768-4d0a-bd6a-b1ed012601f5">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_847f8b5d-8314-4b77-ac05-5a4fb08d975f">2</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c5b0e0b0-7d65-4169-bde2-19a0c678f18b">Volume Pixel Spacing</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5842a509-4e45-4ed6-b2ec-fa274831a67a">(2001,xxa5)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_dfe941b7-e9d9-46a6-9811-b0ad4c96aed0">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_363cdad6-7ada-499a-83d2-89e914159fbd">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7c978496-30db-45fe-ba5b-ddba555e3017">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a14a5f42-50eb-4a5d-85c5-0f8445c0a263">Volume Slice Spacing</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_de9b80ea-9e65-4e1d-b8c5-503d762ba806">(2001,xxa6)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_5afac51f-38c8-4214-86f5-48cd0e32a09a">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_18a21397-63de-4ed8-84f9-63c90731b14c">US</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_36a69192-60a1-4c6d-808d-0d94569b89a8">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e780fd99-7a13-4849-9b6f-410892abace6">Volume Slices</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b9e257e7-d8e5-43fc-89f9-cee81f3a0361">(2001,xxa8)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2039d705-886c-4002-9c6f-d328946a65d1">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_fa14f385-7fb1-4ed6-acc7-002b50613177">IS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b644b4e5-8c2e-4040-9b79-389f8bbb5075">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7ab820d4-6a4e-44da-9abb-8cbe5550199b">Referenced Volume Definition Number</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_384f4c84-3946-4ecc-8df4-1fd7e5081722">(2001,xxa9)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_84214fe8-7526-4434-b754-e8adabd3ef8c">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6395902c-cd58-42bf-b297-a7987663f2f0">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_76b588df-5ad4-4df3-b88a-5dda84a5a886">0-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_97bdeed0-364e-4bd3-8e5c-048445eadec5">Linear Modality Gl Trafo Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_04eef47f-5a62-4bcc-b4e5-e794d609573b">(2001,xxaa)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ab2ae099-c640-46c5-9bd3-aa1a6810e6f4">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6de267c3-de05-4077-8f91-3dae39960028">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_20a30a14-2c7c-4d52-812f-822e913d98e8">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d845c849-ecef-43d6-aaec-b50dd2ec69b7">Volume Slice Offsets</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d4eb0877-1182-4f52-a397-ec46ef87a316">(2001,xxab)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_18cd65d6-5c91-45f2-8ac5-6d46f6ebefbb">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8430aec3-166b-4d6d-b1f4-e42ff71da9a5">IS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_921d5771-4d9d-46c8-8765-42064cc5422a">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8a1d8599-7a59-4300-8c9c-74358e2b3dd4">Number Of Volume Definitions</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a06745e0-151d-4c08-a609-8a1172c1c9ac">(2001,xx00)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_738df125-b080-44cf-b609-646fb926bebc">Philips Imaging DD 129</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_756b97ef-9021-40d7-9794-7eb89da28662">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a7010a2c-4004-4095-bd89-d3ecb1089c20">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_90425a77-ba63-47c4-a7f8-db94daec7b57">Presentation State Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f5ead1d8-22c2-4c59-b643-6c00c1d063ea">(2001,xx01)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_dce57a56-1e19-43c1-affd-6d169f789ecf">Philips Imaging DD 129</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_93bb7a8e-916b-4ea7-a198-f36d8726a477">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9de446e0-ab5b-45ff-9aa4-d9c5d39b9566">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b646314f-7618-4b10-8c7d-8f622e399f27">Embedded Original Presentation State Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_354a449f-3231-4788-ad14-cfd6f8589b4d">(2001,xx02)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8ca02309-21b1-4f7a-8486-a2c8fa86ea63">Philips Imaging DD 129</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5c2f2aae-c288-4789-80fa-d95406bd2c89">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1b666e72-41a9-4af3-b45f-7984d33db1e4">0-1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_33e129b3-eb65-4481-b8c4-13643fc2c15d">Planar Intersection Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_91e4187a-eacb-4089-b3c1-6003287f0b71">(2001,xx03)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_dc6fcef6-0621-41b2-8b70-d2f988b56e9f">Philips Imaging DD 129</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_150f55a8-46f9-4fca-973f-d2fc62222dc9">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_15c2f598-80da-4162-9c60-0c5bed3c6363">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_695ed2e7-899c-405e-8e80-0cc56f6f752e">Plane Separator Line Color</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c7b2b93a-ca7a-41b3-9e47-722a03622bba">(2001,xx04)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_be618399-eebc-4271-86fd-bfad0ff2f93a">Philips Imaging DD 129</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5a781824-ba1b-4eda-8296-83a73180c809">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ce932bf2-ed9a-4c74-ad45-154e691b40e4">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_31d9b0a5-6fdf-4ac2-b69f-1364ac3e0564">Plane Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a71a4c62-f14c-4bdd-8b1c-626c4417dc8e">(2001,xx05)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_35d713a7-3e13-46d9-ba69-a6de09f55d35">Philips Imaging DD 129</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_60fdd66d-06ff-4238-a946-261b97b4ffd3">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_97870a35-8547-46d4-af94-8f244ab02427">4</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3cf220b4-9692-4789-aa03-fdc170457e07">Plane Equation</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8cfb977c-0237-4b0e-ac2d-3200fdb1cd5c">(2001,xx06)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_32afaa81-5798-4f6d-8a5a-815bd4a0b573">Philips Imaging DD 129</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_fc8cd89a-259d-44a1-95b6-c7f8b030f3fb">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7182b742-f3eb-4fab-a0c0-d1fd6d0e42aa">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3a01210e-63f1-4976-80ea-e978fc678a47">Plane Opacity</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5ce61929-afd8-41dd-b468-f42c8b5b387a">(2001,xx07)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ae66770d-c2c5-448a-8981-9fb503e1e3a1">Philips Imaging DD 129</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5c4bb193-b74a-47fe-8ad4-689e4be49378">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_40ba402d-8561-4679-8a45-0aaf4396faf5">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_805afeec-a8e9-4b7d-9a7c-ab76b57b6c28">Plane Enabled</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1cf373c6-d53c-48a4-a82a-4871d764b944">(2001,xx08)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_27758eea-e472-468e-8721-95429a7c809a">Philips Imaging DD 129</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_25fa7305-0e9d-4bac-b02f-d2d0bc035aad">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_09c9e8b3-4214-4cea-98a5-3d11c0838ece">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_708018ac-692e-46f0-b8b4-067ab2a00d45">Plane Selected</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_16043fa9-da3e-4eae-9453-152c5ac525bc">(2001,xx09)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_67efc851-b09c-4c46-9075-fdd825cffe92">Philips Imaging DD 129</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cea6df49-d458-48c5-a2df-a3eade8d5fd9">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cb931f3a-a835-4469-8a1a-a3aaed246fa0">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8b849c54-6176-42fe-9d28-dd2a08fd13cd">Plane Highlight Color</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4b8bf2c2-faa1-4374-887a-c0bede4fe88b">(0025,xx01)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_083ea373-ed19-4d12-b7be-4aed3e241a96">Philips ST80i</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9efcfbd0-d3ec-4572-82a2-7a6074419d55">OW</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a61dde75-8933-46ab-bf09-12f0fe957c7c">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_552e3f06-853b-42f4-955e-ca0dfc54b8de">ST80i Stress Study file data</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_dac625fa-70be-4bae-8df7-9e085ee4ae30">(0019,xx0C)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_76689822-7055-4c5a-b4c5-2bd8329657b5">SIEMENS MR HEADER</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_554b703e-1245-47fa-9e4f-76d7fb5be895">IS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0d6d8be6-a97f-4723-bb17-1084d2973ddf">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_eb306d1d-54b7-4198-9d5c-6ef7b538d1c6">B Value</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_aafa5bfc-8ab1-4a10-8513-2a2760527f82">(0019,xx0D)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_524d443a-aa84-4406-92cd-fac16afb29e4">SIEMENS MR HEADER</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c167dcb9-0580-4670-9495-6f996170005f">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_437bd820-6e3b-4897-89f8-1ceb34356b09">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f2c79c0d-2bd0-44d5-8d85-55c9199c9c2f">Diffusion Directionality</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_284935ce-f029-4e36-9133-d20038ac9072">(0019,xx0E)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_03736ae3-4dc8-4c71-a1e9-37ba298efcf9">SIEMENS MR HEADER</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c712eb93-8ddf-43cb-89c5-9a510c61ec8b">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e50ff8a7-13ea-49d2-8dda-d8cd4ba6e89f">3</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e24b1970-0a29-4aff-9a3e-f3dd1d81ebcf">Diffusion Gradient Direction</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ab8e3ed8-9b1f-4f24-989d-bceff204df37">(0019,xx27)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c56221b9-6919-48ac-87ba-2196995b16f1">SIEMENS MR HEADER</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_410d8ce7-b679-45fb-84a1-411f90ced05a">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_54289893-085f-4c89-b9e8-4f5d01526277">6</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_36abb8ba-78d6-43f3-9665-f20aeb777ba7">B Matrix</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8a98f21a-17c6-4a23-8448-30794e2ed9da">(0043,xx39)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e35458fc-51f0-48ea-97d5-c33b6550f886">GEMS_PARM_01</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_acf7a018-12f2-423f-ae2f-cae7522616ff">IS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5b5c482f-777f-4d82-8c89-a05a434632a1">4</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_826a3cdc-7357-4689-a04c-86c2883f13b9">1<superscript>st</superscript>value is B Value</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e9df6df5-9c22-4d42-a021-f88a4a89d59a">(0043,xx6F)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_dce20988-7360-4379-94f5-b391b89cec6e">GEMS_PARM_01</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4c1fe384-08b5-40b7-9032-4794e8d25ee5">DS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0f9e75cb-ea3b-4631-b345-06508e9ec58b">3-4</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2fd653ae-7509-4aea-bf8e-e361f74a90f2">Scanner Table Entry + Gradient Coil Selected</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_294336e2-6b0c-47f8-8d33-0780a4facb4e">(0025,xx07)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e851d669-a0fb-4f68-9170-c95f599468a5">GEMS_SERS_01</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4ad38bda-3d78-4681-b5a2-99f51387f03b">SL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a4f31d5b-52b5-4bd4-986d-c4ae29b39a18">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f7f04a05-dd96-486d-8c79-24ca5411cc77">Images in Series</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_52172927-8d98-4608-a277-426ba3a4c794">(7E01,xx01)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3c31b64a-4125-409d-934a-bb50c43d3907">HOLOGIC, Inc.</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1e607850-2e69-4f9b-a4d8-425912356e21">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f94664cf-d7ee-4f88-824d-7292656d8702">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_72cbf734-955b-4079-ac19-50a6f9366e9d">Codec Version</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_48f8616a-ecd5-4c1d-91c3-baaf8733b87a">(7E01,xx02)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8ee2c453-77c2-40c9-8de8-f35182bc8d2d">HOLOGIC, Inc.</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c7b07239-10df-4940-8356-6e7ac791c2f3">SH</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_274f76d7-db0d-481d-8e6e-b5d1ff8d3e5a">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d268d7aa-0905-4de6-97b8-d4fbd7b92792">Codec Content Type</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6d30e134-774a-4009-8cdc-d53681fb09e4">(7E01,xx10)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_95a9cb5b-b584-46eb-8298-9aaa319721d6">HOLOGIC, Inc.</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2ff9dd4c-246d-4dcb-82f7-e89ab5be8089">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_14145676-100c-41a3-87d4-7ba031c7a490">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d641600b-cf7f-40d2-9d3b-354c7e9180b8">High Resolution Data Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a714e9bf-958d-4d51-928d-7ca7486bd837">(7E01,xx11)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b895a268-9a9e-4ec4-aaa1-ba9c81090f22">HOLOGIC, Inc.</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1087d744-b36f-44b0-a7b4-231745e65740">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0ad68691-badd-4cf1-866f-3ba649f1e677">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_33383e5a-1540-4cd3-8b02-27ea54fc0534">Low Resolution Data Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_db2a7176-486a-4978-89e9-eb1c1cfba963">(7E01,xx12)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7cdf9c1f-1944-4d55-bf1c-13e8edcc567e">HOLOGIC, Inc.</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3b0e13c1-1ed6-497f-ba86-3a2549cad152">OB</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2516dfb7-9be8-441b-aca3-b71b84472145">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_dd87b3ce-154e-46a0-80b9-ea0a923e844e">Codec Content</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1ab639a1-ab98-43a5-9ab5-41129eff4407">(0099,xx01)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6ed7a328-17c4-4593-acb4-baa3d8a155b2">NQHeader</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4ece9c28-c15b-4c91-81a0-c03f9725e430">UI</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_682a11b8-f4f0-4253-9e25-0c937e9eb7e6">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_fc05f4c8-9801-406c-a9be-2a54a6ac0efe">Version</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1e63427d-ea3f-49bc-b610-b1189922439d">(0099,xx02)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_249f9ea6-6e26-4223-9dcd-231767e638eb">NQHeader</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b8b0601a-07d0-4b07-bdaa-f2c8687b2a1a">UI</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_04a36e11-2f63-48dc-8414-7de62f1f1c06">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_24835adc-2f26-4aec-8948-f34c597a2376">Analyzed Series UID</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8e9ff797-789a-45a9-aa90-817f1fb1bc0c">(0099,xx04)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_35c69ff7-c40a-4aae-bb25-24bb9802bb68">NQHeader</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1820654b-6632-4f31-8b90-787a7a5f29a7">SS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_45af0c99-303f-4f45-a340-687b72658474">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_5d887fcc-f6d6-4a6a-9268-f35de5831134">Return Code</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ae005f04-41a6-4cac-92dc-f54a79ec49ec">(0099,xx05)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_01c869d0-2314-462c-bc51-9e96af2e9c4f">NQHeader</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0906b8dc-4276-42a1-8e24-78e4bf2ef952">LT</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_55fca35c-209f-4d93-b5e6-ad616d329b9a">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_853445be-fe5e-4a73-8830-0df89f86f289">Return Message</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_95625396-a2f0-4396-bbbf-8138497bb27b">(0099,xx10)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2f42bb84-e01a-4976-a5bf-7de84f60aaa2">NQHeader</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_afd1de20-be20-42cb-90df-431cf17f2a59">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_eeb3ec7b-210f-44bf-8a66-81bd6a9a5591">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f4bd1a59-41f4-4a19-b3e5-53a833a60b8e">MI</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_874ba2b0-a7a9-41a4-87e7-d6e640352e4d">(0099,xx20)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4cd6dc99-b599-4f70-9bed-f46124318de8">NQHeader</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_643fba9e-af54-4941-9df0-a91d6cbb5f86">SH</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d251d18b-e810-4d3b-aaa0-5323bb26130d">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_53538561-8489-496f-9dc5-5048dc8b3468">Units</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_86ae9e8a-f427-42d1-a51e-dd810e59c71e">(0099,xx21)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8c8cb1a7-e716-4a22-9114-1cdae37136cd">NQHeader</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7b601242-994d-4a76-8a1c-59497bbd3738">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f600cbce-67c8-4de0-a2e5-e95455073963">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_92dc52c3-27cb-4716-8b7a-19882373771d">ICV</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f673b404-3fc7-445c-9f6a-6144355d59ab">(0199,xx01)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a28a730a-c5e3-4c2b-91f8-aa49085f4d81">NQLeft</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_17c6de01-0f89-420e-8e38-265036d6817e">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_84848536-e0b3-461a-9bbc-ac9051674704">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ceab1ad9-f3c7-4ea7-8154-f191c1aa3cbc">Left Cortical White Matter</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9d2f82cb-2335-4b51-8691-c4e1e144a7ce">(0199,xx02)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c7227d47-5dbf-4ab7-895e-c8703a3d5af8">NQLeft</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_15d30b49-fbe2-4176-b111-40c412412609">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ecc936c9-c5ad-49b2-a431-4158e557bb14">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_347602dc-8e32-409a-a2ca-42e07681d6c1">Left Cortical Gray Matter</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d6024eb8-feb5-49d0-afc9-77a4d11d3ef4">(0199,xx03)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ffa6746a-498f-4778-9c0a-a04aa4a943f8">NQLeft</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_209c3183-9083-4ca7-9945-b75e52619cfa">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8eedc9c4-6983-41f2-a566-17aade007606">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ebd040d7-3b11-4bf7-bde9-5ff4f0085812">Left 3rd Ventricle</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7f4377ec-f35c-452a-aa77-46765f8a2b79">(0199,xx04)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_34444e70-420f-441c-941b-933a9ef2541e">NQLeft</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8cae52d0-3932-4276-9037-35f3f998fef4">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_91942eb8-5c7f-43ef-893d-293221fde896">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_dbdb467b-4eb7-4786-8e51-aba29d7b549f">Left 4th Ventricle</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_90d5dfcd-1812-41a4-972a-9e5a5ef81710">(0199,xx05)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_46971973-9d7c-434e-9f2b-d61eca472b86">NQLeft</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f6bd0de4-6c7b-40c1-a04a-15a10c8a0ea1">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_acbdf304-b975-4ee5-a167-c5374a6cb280">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b14d7a54-cd2b-4c5e-ab23-c1c3ff4fb7c6">Left 5th Ventricle</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_670938c2-00b3-459b-aa08-3b71cb784c08">(0199,xx06)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b0d825a9-5416-4dcf-9653-fd7b0e48084d">NQLeft</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e77e60f4-2551-48a3-8b97-db7ab67bb8b5">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8d79b3b8-21ae-4cf8-ac85-8e4bf2e289c1">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2fbbe4c5-3304-41ef-8d72-489f87489c16">Left Lateral Ventricle</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b2d10b08-aec2-4440-8720-79ccff396122">(0199,xx07)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e79309c0-60ea-4796-95ae-f1cf8b242441">NQLeft</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3b888ba7-3a9d-42ec-a566-27091b298071">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3b49f1bd-b179-44e2-bd90-bc87b07f0d68">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e8d6fc58-dd25-44b7-b8b7-7d8ecdfed574">Left Inferior Lateral Ventricle</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_34e6558b-2f39-428a-ac14-7fdfa7c9be1c">(0199,xx08)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_84280f29-b30d-4972-b9fa-ada7702d48e7">NQLeft</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c2960f85-3c0e-425b-a544-484f86c2d4bc">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0f8ba6d5-fba6-495d-bcc0-58a930673ebb">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_df038597-257a-4914-8aac-b69c7cd4e1ff">Left Inferior CSF</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d94d6b61-a28b-499d-87b9-7fc7b4795971">(0199,xx09)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1b993c41-be05-4166-948e-575604544067">NQLeft</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ef48ab18-3c37-42cd-ae31-175d7f383cff">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b872bd38-c33e-42c0-9261-60f6276f290f">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2de61b00-5562-42c4-a318-dc38f285bc90">Left Cerebellar White Matter</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d9390268-f5f9-42f8-94aa-213681f932aa">(0199,xx0a)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ac252ca0-5b85-4d21-92e7-57d2a15b7b28">NQLeft</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_811a41fa-e42c-4316-97f6-5ca515a43c72">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8d6b8612-437d-4a87-a87e-552dda1b59b8">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2d8bd432-3ea9-440c-a361-429ccbde44c7">Left Cerebellar Gray Matter</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e99442b7-df8c-454b-81af-3d8d4c2fed94">(0199,xx0b)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_5dc400a1-624a-462c-82e9-d0eb92431c00">NQLeft</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_73dba275-03ec-40ad-b6c9-c2c82d78749c">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f391d53c-d116-4a1c-a206-4dda2f7663b0">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4a2a5bc5-2dfe-4e22-8108-f783e2a757e0">Left Hippocampus</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_55bb99e0-fb88-434b-b811-9db94a38bddc">(0199,xx0c)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d208a821-5e24-4980-a941-c70b70da53db">NQLeft</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_644ce3dd-2281-437b-b0dd-05490a0e8f3d">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_dd9a0ccb-7110-429a-9a22-5caca3cdc8d0">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6c5dae9a-1098-4217-a034-0eaf28f2f29b">Left Amygdala</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b7d0de85-77ec-4be0-ad5a-bcbf123b4343">(0199,xx0d)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_783554c4-444c-4433-b46c-e7e0b10ce3aa">NQLeft</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_fee6e7c8-3b71-4de2-b27d-d65b43eb4b3c">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_35287f54-6152-4b05-922b-14814afe1a49">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4b4475e6-2590-4a5b-92ea-a55bd29b0f41">Left Thalamus</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6f13f7e0-e3dc-4b69-8a97-0ce971646741">(0199,xx0e)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_845f82cd-a66f-4be8-afdb-5fcf90fee916">NQLeft</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3fcae7ed-279d-4a36-8a9a-cf47991b89af">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_81efeea5-01dc-4c52-8b03-60357d27f373">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6e558a0b-f465-42d4-85d9-78002dad3458">Left Caudate</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d5a962a2-4dd7-4960-b622-3b3d6aae9cfb">(0199,xx0f)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_0274839a-76e9-44dd-95cb-30d6099b0c73">NQLeft</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3bf66f9a-6820-4e75-a27e-6a30c16b0187">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_043b3a7d-0c7c-4aa6-b380-278897aee725">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_028a6251-bd91-4056-bd9f-73088677d3d2">Left Putamen</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_109a20f9-0f72-4f61-8d7e-84c9c1b7cee7">(0199,xx10)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_66840ec3-55f8-43ba-ac19-9ddf0de2b117">NQLeft</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_46c1e2eb-d903-4388-81d5-158b6aa2c91b">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3cbf7f43-c43d-4304-b00a-29512df83ac7">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e179ad2f-ce3e-40c0-aea7-ae48385b8c84">Left Pallidum</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_702dd5ee-381d-42ce-8589-b1599aa86fda">(0199,xx11)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_88b3c649-6f31-42fd-9b91-7709309fd3a8">NQLeft</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_99c9c295-8de4-4bfe-8ff0-4b1a21ddbed0">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_06dd3a3d-eeef-4332-9d80-facdb04017b9">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f49822ee-bbb2-4da3-88e0-4b3620cd2686">Left Ventral Diencephalon</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_60f28d11-9a2f-48da-a7da-dba93c34db80">(0199,xx12)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_65283e51-a52c-48a1-82a3-91c13da08013">NQLeft</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8d3e5552-3b5e-4cde-835f-60526e89a7f3">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8dacfcc9-908e-41b8-8eff-81579988e9cb">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2cde7832-a1a0-4b5f-974e-ff4a8eaa0eaf">Left Nucleus Accumbens</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7dd0521e-f438-4fd4-a613-ed726bee9d96">(0199,xx13)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_325e349a-0a30-46c4-8016-d0206b6de53e">NQLeft</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3399b473-3589-4ac0-ad63-49e33cb1a1f6">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a616af8c-be3c-44b0-ac8f-cce7534bf301">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a1bc50ed-5a16-49b0-96f2-8d8125732a8c">Left Brain Stem</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_721e120c-4270-475e-8e3c-30c99524432f">(0199,xx14)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_69e57694-5aeb-42dd-be68-0d3fe085da5e">NQLeft</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ac4b855c-502f-47cf-93b5-f81651945b9a">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_50e981be-55e6-4a83-96c3-7c4535d3b5fa">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b34ff1ff-07a0-4fab-89bf-e738981df0a2">Left Exterior CSF</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7a0300ab-60cf-43de-b1b8-3a6caeb760c2">(0199,xx15)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_735c4281-46a4-41d3-8388-6836968e5c3b">NQLeft</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0342530f-0b1f-4f20-a7cd-28bcde829d91">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_666741d5-ae9f-434c-9e7f-12ce49cd480d">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b77d5097-6358-40b9-a7ac-4a2eb288a8cb">Left WM Hypo</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3c953867-68a4-4719-9d98-832bbc3a9346">(0199,xx16)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_634b7c1f-b8d4-494f-aa72-01eed711248d">NQLeft</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3c6978d5-9ca3-4d5d-9c68-c43aa2f8080c">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e7ccb7bd-e63b-47e4-b522-afdb7aa64891">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7b3be632-3d69-45f5-a3a2-bd6e0eaf3a79">Left Other</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e433898a-d00d-4885-8d1d-3095b9befa92">(0299,xx01)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_cc457c38-f85d-411f-833d-2464b2019ffa">NQRight</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_edf7d4d9-97cd-4772-bedd-304e69eb6891">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8d919575-ef85-47eb-a2ac-72bafbe6c3a0">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_496a2c9e-c0e2-4d99-a01c-eb9a00e2b5be">Right Cortical White Matter</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b7d5cb76-e163-4461-8054-b4c3bcbcd440">(0299,xx02)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2c78c615-820e-4aeb-815d-4549db85ba63">NQRight</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_726c49da-b195-4b19-af36-a3a2b9bcd435">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c6770da9-075a-4080-9d59-34c3ab992d3e">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b6e093b6-1fae-428e-8221-01b5d9289dcc">Right Cortical Gray Matter</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9030c636-d253-4b6f-a5b4-f5c978de8732">(0299,xx03)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1b7c0a25-0757-4a5b-9a8d-1a1fd1ff3045">NQRight</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_20668c9a-fdf6-4832-acab-4b73e01b82a5">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_47bbe9f7-019b-413f-a358-604dd44a3c55">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4961eb79-c2a3-4966-aa93-b7a40ec134c8">Right 3rd Ventricle</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0c01a714-e3f4-490a-8cec-f17e5a4142ad">(0299,xx04)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f95e411e-4a8e-4037-a027-f0a2f3d5c598">NQRight</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8b85add1-707c-4af5-be7a-b626b8b9e04c">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9e032fd6-6347-4783-b278-8fad73a78e1d">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_eb7496a5-01bd-46d1-b00a-83122e17850a">Right 4th Ventricle</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9e8185b1-c325-47f2-9b10-636b88674223">(0299,xx05)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7f785994-54ee-4a4a-9187-76a6bddfcfeb">NQRight</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_76f9f625-f80d-4fda-8b2f-0f500b0634d2">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_50607731-22b3-463f-98a8-4c9f06fe57d6">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_08b122d2-7449-4c20-9f3f-b110d1ffe8c4">Right 5th Ventricle</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cbb0ed2b-25a4-4793-a4be-defd6d85140b">(0299,xx06)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_28116473-f4f4-4a4f-832a-c6a7e1c12737">NQRight</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_af3ff3b8-a2f5-4d28-952d-bb76a6868bc4">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b899c439-cf7b-4d28-8984-91c852cda05a">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ace23102-e604-49e7-a22f-e3cc48e9af2f">Right Lateral Ventricle</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0fbf473b-785c-4711-8c53-a46121d52447">(0299,xx07)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_460a89e5-c7c1-4bc9-a73f-8722f6a4a160">NQRight</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e93cdf8f-6e2d-4073-8f7d-0ca083a804d3">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_de8b7540-96a2-4f80-b4d6-465180e3f53a">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_465fe964-7a06-4bc1-9cfe-0133349532c8">Right Inferior Lateral Ventricle</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c8ecb18f-db70-46aa-bd2d-d3d47df5807a">(0299,xx08)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_5975620f-d4bd-4269-8ff0-d80eb2d6f8ca">NQRight</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0ddefe2e-1793-4b44-a202-b41f8971eff6">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_29c1384a-0426-4092-93ac-4083ea11aa21">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4085685d-0451-4542-98ef-e3411b547f54">Right Inferior CSF</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0e56c38c-599d-491f-bf6a-f72ac32e235d">(0299,xx09)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c8ab9117-2348-4c17-b992-93d45b1b8be6">NQRight</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9ca139c8-71c8-4e02-8380-2e685d9ee7cc">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a8429e79-5d56-4434-a2e5-bf3f5ab6021f">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_9c9d6cef-8dd4-48a5-bc21-a177cbb06390">Right Cerebellar White Matter</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_825cc28f-7deb-4929-ad3d-e5c09645c364">(0299,xx0a)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_31d6333f-3819-4100-9deb-0df4e40ad59c">NQRight</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4754ea29-9f12-4f78-8231-e5d2db651499">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_383bfb3d-cb05-48b6-8a68-cea28272f5c7">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4e27c5fe-9e23-4fd9-a7ca-7bc199636a21">Right Cerebellar Gray Matter</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9570611a-4f61-4551-9611-6e267230eebb">(0299,xx0b)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a549c25f-0a0a-4189-a510-aecfbebd80ee">NQRight</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_797463ae-a316-4a7e-b645-5146aad6a1fa">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_80e3c036-24d9-4925-865a-26ead5ae6259">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c4aaf167-80ee-4a4e-8144-c54c50726088">Right Hippocampus</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f2519cd1-d511-4e43-ab15-9c5ded946291">(0299,xx0c)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6aad1be6-cda9-41ad-aaed-c0b9c822c3bb">NQRight</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e9d9aa45-72b0-4698-b71f-e83eb85f3642">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_277dddbf-9ee6-4c2b-b26c-f81adaeeb9ea">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8938bb97-050b-4d20-b0d2-dcb2f46132d9">Right Amygdala</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9c9a568d-11b9-4cf9-a4d2-19e0bfb1b2db">(0299,xx0d)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ee7ceeed-3c8c-4a63-874c-bd41c9672952">NQRight</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_78b2bbfa-629c-4f53-8d5f-d10386003a4e">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_30ca6e0c-3904-4164-a3c8-7fb9956abf05">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_59014f87-a665-416e-9478-dc890c4e2758">Right Thalamus</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2af9e4d8-efbb-466d-8b72-54345b75042a">(0299,xx0e)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_793c78bf-29f1-4aac-b82c-4d8fa63989e2">NQRight</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f21ee925-ae4a-461c-a0b3-14782eaa986a">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_55fd05be-a2d5-4689-b25b-9db8aa6f9ff3">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_cf54a7d4-b1d2-4e79-9db0-fd2996e7889e">Right Caudate</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_684d72c8-a4b2-4566-97e9-ae6aa5381de8">(0299,xx0f)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ef66b8e2-2d50-4515-86d5-d6d56b3193b8">NQRight</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_07253e64-cbea-40bb-a899-e96437c8d66a">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_fc0129ab-a44a-4372-a2f9-dbd5383e791c">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7bc97ad9-c5e5-4289-a6fb-e4632b2bf6df">Right Putamen</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_75e21ba3-e4a8-421e-b054-b1b6193747f4">(0299,xx10)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_91e249a6-6c9f-4a79-868b-3202ceaa14b9">NQRight</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_70352e36-7aea-47ff-aac8-f3e297426f91">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_56884b27-05e4-4672-9518-f17020f63312">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_50f367b9-c8e2-4c2c-9e27-a638cf16f272">Right Pallidum</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_78956412-e1ed-4ead-8518-2eb7e42f940b">(0299,xx11)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_acf67158-ab44-4d83-9cfc-30d2131cf758">NQRight</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_444ab539-fea7-47d3-9aff-f2b92aa07b4a">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_30c6e17a-9dd8-4727-84ae-ba680f6620e7">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a6211641-386a-4d5e-8607-a27bbf67e820">Right Ventral Diencephalon</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_19021ce9-c3c2-4092-9a22-26239a4e5476">(0299,xx12)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_9f3e3434-9faf-4a43-9394-2bc8a04384cd">NQRight</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2fbc29cb-f208-4a57-a644-9705760658ce">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ee46f98c-ca1f-408d-b84b-b46666b824d9">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7d95ab69-3819-428d-815a-5686cd2d3c8b">Right Nucleus Accumbens</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6a8924f9-55cf-415e-8b54-59dbe5d5732d">(0299,xx13)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a2701963-43b3-4f71-a711-1b9c26d19390">NQRight</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d1c1d39a-9e46-4ef8-9312-0178aa47fefa">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_80f19500-db02-401f-b97a-773aaba8e106">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_addc5675-d6a5-4a9d-9d11-24767b4d6f5f">Right Brain Stem</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2fe8d6cf-de0f-4f71-bcb9-49f58592bce5">(0299,xx14)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1ce10bf8-d7f4-422a-8d05-067aa5c72e9b">NQRight</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_bcbd13e0-6638-4507-b3b4-1bfd783e5a7f">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_24c9c630-4b7f-43fd-8b7c-4221bfe0eb27">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_593dd8df-2c5d-450e-8056-416ae8b2fcad">Right Exterior CSF</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f9faf2b4-9d52-4f80-8251-d023331ce342">(0299,xx15)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_9c1913ad-9ccd-4237-a6c8-71c1c3aaca42">NQRight</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7095e604-ecc2-4fb2-a284-f7a983626cfe">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e443f1c3-cf46-4ef3-aa4d-a909a75751a5">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7394ccf3-e1df-4a96-ab32-d14412f114c3">Right WM Hypo</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0e63c73f-f21f-4f34-958b-876cf54a2522">(0299,xx16)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e52d52db-c35a-4b66-872e-97a92e1f74b6">NQRight</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_382210aa-2533-4a5c-9869-eedb2d6d886c">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4bd6bb99-4f3a-4421-8cef-802905efd8c5">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_adb48c50-12e2-4dec-ac8d-f6eb7f25ca37">Right Other</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_afdb4a4a-328c-47f7-bbdc-d2c7bdda6c7a">(2005,xx0D)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a65bf668-904d-478c-930a-03bcee601f02">Philips MR Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_979b3b65-7610-4ab3-93a5-7e705c072eb8">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2d0aad10-0578-4925-9a2c-6a576a61ce95">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_dc63a35e-6a93-44d7-bf93-e1c61128af68">Scale Intercept</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_669d8845-00e0-43ba-97d4-e2e529c9b0ab">(2005,xx0E)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8a4151d5-5b7e-40f2-a6c3-2285de028e91">Philips MR Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_374ca135-79a5-4b6b-8396-6ea0bcdd696d">FL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f1a589f2-b9fb-4d4c-a7f3-ce913fc6a6bc">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_df3cefa0-3034-4123-8012-2ac3d2b8dea8">Scale Slope</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_fa98d4e1-ba60-4f0c-b92d-7aa91bafcbd2">(0119,xx00)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3d1d64fd-a0cd-4252-b14d-9b81ecd615cb">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_537ffe7d-3ab6-4acd-844d-0448366ab4dc">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_76c71cf1-e823-41e8-92bd-2b49dcb36ccf">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_daed5bc5-aa17-43d1-afdb-ad2563c4a636">Acoustic Meta Information Version</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2c9169c4-e4ca-43b0-b684-892cf95dd1ad">(0119,xx01)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_004270aa-953b-4099-b239-00fde1607974">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4186ca28-fd8d-4589-914e-7ad83fa2125f">OB</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7b3c118c-cb3d-4d45-9cb1-5a614aa6b46f">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e59e9a43-f38d-4a34-8dd0-61352a4d5f03">Common Acoustic Meta Information</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e6202d74-c65b-4b94-8aca-d8560c50d1ba">(0119,xx02)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e9b04935-b16e-4827-b986-0f7be1747814">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_45e218d8-0197-4dc9-85ba-388850861090">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3dcdea4f-8d71-4de9-ab8a-97b99a18166d">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_92d74b24-7d95-439b-bb6e-713c7a4836f4">Multi Stream Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a741376a-d13a-4942-bf49-fc647d76fb10">(0119,xx03)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_718f785f-be1b-4c17-a529-2440a0fc11ae">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7b840e29-8f5b-43e6-b33f-504cf04395fd">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3aa4b0ac-a2a7-467b-ab81-bb4dd0bc434a">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8862e8e4-8c20-4d66-af60-f4a29f9028ab">Acoustic Data Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_be5f8423-75d7-460b-9c24-55bb4035cbf0">(0119,xx04)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f3391dd7-0dcc-4ff8-b413-94718897a478">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4f7d90a2-57d0-4820-8495-ff1bf737c82a">OB</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_dc8fe350-e51a-4680-8c32-991f327895dc">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a9ed3cb2-5799-4e8e-aa6f-a1a27d025b3d">Per Transaction Acoustic Control Information</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_665bd93e-07ea-4538-baaf-f0c624bfc46e">(0119,xx05)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3d25e294-c0ed-4888-ae5a-e7d179b5c666">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_67a9e52a-82de-4f32-8788-8a62eae24a7b">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9888861b-9786-4b10-a015-eabca97722fa">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e2b61792-e749-4554-82c7-4f5446d875ab">Acoustic Data Offset</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e9e2a1d8-c14b-4eda-8200-f215017d01a6">(0119,xx06)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_cb45650e-99f5-44e6-83f3-7f3b4bff8b29">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_34fab6d0-8c74-4b61-b582-3e2a5d106620">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5da00562-3923-47eb-8c49-b2b89bd2fb11">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_61cb6b36-9f77-4b68-89ab-9bf113742377">Acoustic Data Length</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9b20bf44-fb26-4b51-8396-b39069c0cc47">(0119,xx07)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_339c8475-6f46-43a3-9f9f-8ec73b8c8ce1">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6f26919f-33e2-4607-b374-63966004ccb7">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1ea61a6f-e84c-42ac-9c84-274d3abd9fad">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1b9eb3a4-ce97-4ddf-8685-7ac58ff5e855">Footer Offset</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f5320383-e63b-45c7-a393-03ddef392e18">(0119,xx08)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c71df741-228e-4e53-b475-e0278e37f58f">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_92a37078-a826-44fc-a1c4-3ada5b19c155">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_790438da-78d5-4607-b607-ce02d2307fb1">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_558c294e-384c-4af2-bb4f-f529744878ca">Footer Length</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a4954701-48fd-42af-bffd-c2ba4e852aeb">(0119,xx09)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d3d681a4-1d81-4eb9-bbdf-b18e6282ba7c">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b87be063-a73d-45ae-be26-86a9c2944fcd">SS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9fa73fa5-a16b-4913-9f43-2e8605e78d3b">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_0dbe789a-f950-49c1-ada9-6bb6c10f9fcd">Acoustic Stream Number</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_09a29ee3-1cf2-4e0a-97a4-63c1088cb57d">(0119,xx10)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_59702b5c-51d3-4c0a-a772-baf33ed1fa60">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_620d6778-b3f4-4cca-9d11-a8379c0f01dc">SH</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c1cfe4c6-633a-4f01-b8e0-ca0e71bc7a73">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_610f07ca-9552-4d22-8648-c8007ea1aa9f">Acoustic Stream Type</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_47479a56-c6ca-4a84-a9ad-763360a75183">(0119,xx11)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ead616cd-c166-489f-adee-f9654a4f4402">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_72daaf38-372c-47c7-9ac4-440852ad0525"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cf52b603-cdd3-41b0-9866-12303a05be6f">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e749876b-ef7a-4a94-b502-81bf91499d11">Stage Timer Time</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2b3977d0-4754-44ce-b57e-f4b1b57e6141">(0119,xx12)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_fa5287ed-226b-4a87-8f17-3a1c190f711e">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8ec3e3d9-6e9b-430f-a9f5-2bb7a590ff73"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_67db85c4-550f-427b-b685-f4c72eed8bb2">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_59b9a07b-c6de-4cb4-bbbf-0e91fb9775f0">Stop Watch Time</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_19ae28cd-693e-4d00-9a18-a191cd590af6">(0119,xx13)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_586dddec-7a11-4b3a-bff4-0d90abfd51da">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_51048300-18ed-475f-aab8-4c457010b913">IS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6a570823-4edb-44c4-883b-5e837ebfb15e">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_bf1ea9d3-cc24-4c48-b24e-2c32dbdd4e06">Volume Rate</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2c87e854-648b-4d57-8c8c-edb9c8514eb6">(0119,xx21)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d52dddc4-f5db-4c90-a2bf-9f3cb05c417f">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_350276b5-7306-4522-bfb7-2f28a6063c4b">SH</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5f3e3328-dbdd-438b-b1cf-b8818fbbef18">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8232fad4-910b-4d19-b2e0-90e155eda906"/>
                                        </td>
                                    </tr>

                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_20b5ad8a-eba0-447c-b7bd-322f05476c21">(0129,xx00)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e127247e-e06a-46e4-b6e3-cd3b41b143b6">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1d15d432-0282-490c-a2ff-03c9862524c6">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d0f497a5-519d-40c8-b87e-cee08f807842">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a6184b2c-7b36-418f-855b-6af16c20bc29">MPR View Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f1eee3f0-701f-44ef-8b18-0d4ecb88adf4">(0129,xx02)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7308a16f-c3b1-4028-9584-8f639eb1e42b">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c5bac947-8af5-4d37-8289-37d061870a07">UI</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4d6466bb-2d3f-49d0-bea6-d297617fa0ea">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e0a0f11e-30da-4ec1-8844-f0017a51f35e">Bookmark UID</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_fbd355ad-1dbe-44c2-8ae8-2ac91d4847be">(0129,xx03)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d3cc32ba-5c5a-4e5f-9d67-2f84fcf2dca8">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cd107e00-7f5d-4068-8603-13c576b02ceb"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_44cb7d0d-ab29-4f80-a08b-e3eb2122c749">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d70caaf2-6778-4a65-901f-a8ae685cac58">Plane Origin Vector</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ef29b6ee-fbad-42b5-b28b-a4ef2efdd0a2">(0129,xx04)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_31fa6369-2b12-4c4d-829c-e7a3d38d1966">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7ac4dc96-0269-48cd-84b4-e4b93a7a9458"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8803c927-ec0c-4d7a-81fa-41a345eef9fd">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_31a10ba2-0eb2-44ea-8086-be3a1d78c661">Row Vector</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b825a5ab-e99e-46fd-9768-94b8bd8641a9">(0129,xx05)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_708ddbbd-5482-439d-a6a0-264d701eaf18">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d6de09d1-e2db-4731-9cf3-26242a39e19c"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5958872c-abf5-4ea2-97e4-200b35819c45">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7a63527d-dd36-4e87-80ca-26b022d32ec0">Column Vector</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4f594f9a-a845-4c1f-8f32-0629a658b671">(0129,xx06)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b06f835b-fac1-4662-ab15-dd7b749e6055">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_480a221e-bb19-4e1d-aae7-2398713cb0d3">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_44c018f3-85f5-4478-b4ad-688874a2356f">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d2a39b42-9746-4046-851c-cae26fa352c3">Visualization Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f27ef0f1-4207-409f-9ba1-fef6036e2c57">(0129,xx07)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a0aa4676-56b8-428f-8e6c-c1d8c318bc52">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6255aada-1088-44d5-8757-4862fc12b9e9">UI</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_abb3000d-1fef-4d9e-b52b-5924492e7b3e">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_fe4a7b6e-fe61-44e0-83bc-10a40a21e55b">Bookmark UID</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_02d772db-80bc-4278-b068-08c919c25922">(0129,xx08)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_9bafb603-c577-476c-9ec1-bfd4441fbcb6">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_699790fb-d6a1-4ba3-9854-14d5b4c6dc75">OB</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_308c86ba-e9a1-4d28-a4af-8065a55c9528">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_729427fb-02db-4ec5-b1a6-e04785084eb3">Visualization Information</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_785c2f71-a55e-4395-9f39-4f5c9ecdcd60">(0129,xx09)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8b7cafeb-b33b-487a-9971-6c7f0c50445c">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b39c940a-ddbe-4c90-abf1-f67cf6b015cf">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_82aadf23-4901-41dc-8fea-6f64777da5ea">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4a8a556d-df5c-4e1e-a1fb-8fb48fa4378d">Application State Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_902e3b5d-ebac-4fca-8bc3-ccd8e5f9b1ee">(0129,xx10)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_88ea089a-9431-42a0-a598-b21e0ed12931">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_40525cc1-8ecf-4c70-b09d-81ab305d424d">OB</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0d4df1b3-6745-4b5d-ba45-4a32d7d9b1f7">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c8deef0f-21f5-41ba-a315-ddff2abbc1b0">Application State Information</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_01ea828d-d0cc-4194-beaf-dc75197b1d1a">(0129,xx11)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7be58f9f-5131-47b2-8917-7358e5d0c69b">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7f1cb4bd-2f67-4abb-a65d-12298fe72db9">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_409a24a4-c4c8-471f-958a-523af2b57c5b">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_75b2ec68-f54d-429c-8ce0-30640ccbfbf1">Referenced Bookmark Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d1754819-cc20-4601-8a99-5195d8a84c83">(0129,xx12)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_329dfcd5-ec00-4538-8e78-9ad7a92e1dc3">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_244c23dd-b979-41a6-8d89-4d91c8070ee3">UI</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_df4d0f5b-472f-4d27-8b15-f9e7fd956238">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7be934ce-9beb-4138-bb3b-a3738b01518e">Referenced Bookmark UID</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d14698f4-1058-475f-b567-8c785328aedb">(0129,xx20)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1a4652b1-8c8f-4cc6-88ed-d93bbdba4be3">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f109a9a1-77df-4705-85d9-cb00c7aee3c5">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cac817fe-5222-471c-bb06-5c51343e1936">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_18b90359-d47d-4dbf-a119-592f4210e737">Cine Parameters Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_04ac1aba-d6de-42b3-a9f1-674e58b47638">(0129,xx21)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_bc81969f-4aa8-4986-923c-801f8ac65d09">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_32c4a20a-e434-4aa7-a6c5-09b5c183c08e">OB</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_32c9b815-2294-4aa0-a2aa-5dbd1ca6e01b">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e850f223-084a-4e51-9b65-359c5efe3d2b">Cine Parameters Schema</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_06feb66b-a797-423c-ab89-da891b4d70e6">(0129,xx22)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_100caf97-1f16-4e5d-af55-3465c9099456">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_37ce2deb-a2a0-4117-b61d-b487df1d662b">OB</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_81fa6c52-0aee-489b-98f6-f25fc3b21444">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_af835ca5-4931-431c-9643-f1118b072d16">Values of Cine Parameters</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b08f1bc5-7f98-4bf6-91d2-77a1cf0b8d0e">(0129,xx29)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_35f98965-0962-4bda-8091-0d34335e1fe2">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cf062fa4-6d88-40b6-91bb-91bd8e70db60">OB</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f859db99-1674-49ef-bf75-35b277514b0a">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e6471908-5bbe-4fd0-8fbe-138f13bace4f"/>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_df1b6fbf-1825-4222-b965-2b2e180348d6">(0129,xx30)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6fd1b1b1-8e64-42d6-ae33-242b6c2b9814">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1ce54204-b2d4-4951-bede-c6b7f0cdc99a">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e56b02d4-be4c-41a8-b714-f777c96aecae">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_669cb0a6-c93b-4819-9075-c865cad9a56c">Raw Data Object Type</para>
                                        </td>
                                    </tr>

                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d95524ef-3021-40c9-8afc-8fa967e4b5b7">(0139,xx01)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2c4d38e6-73da-43dc-bb6d-c1868d5d0fe4">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4b824c01-33e3-46b6-8655-6222fb7e3802">SL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1ac39b76-f60a-4f9a-9456-3613fac9340c">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b09fa8d7-1df3-4757-9156-e131976cd443">Physio Capture ROI</para>
                                        </td>
                                    </tr>

                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f24d8828-3546-479d-aa8a-2e05172bc5d6">(0149,xx01)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7ff74c4f-fd0a-4cca-ac37-8e81254070d8">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3f2161cf-72f3-45f5-b1ec-027939fe9b92">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_145d70a0-98e4-4d0b-8b56-a0e86a1b30d9">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a0e0999f-4101-49df-8081-fb6f5a87ab04">Vector of BROI Points</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4c49abee-9b99-425f-a6ea-9602356a8aae">(0149,xx02)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_9918226d-5874-441f-a1b5-b970036e79a7">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6b4f0cee-0405-460b-a44f-0dcfe97707e9">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_08e8b6b1-1a3b-4dfc-b237-11dcd3929578">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_44c8b1b9-f18a-4c29-b6c0-1229f5d165bd">Start/End Timestamps of Strip Stream</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ac49cd6c-4775-4a17-96a3-14d58ccc42f0">(0149,xx03)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_fc46f918-5555-4953-9f55-c92efe0165dd">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_755f7ba0-f9e3-4a15-be64-946e8e5e5ef8">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f75f0c34-d20c-4214-a07f-bff83ae2a1ad">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c3b35ca3-787a-4913-b3a2-38715b42d1d3">Timestamps of Visible R-waves</para>
                                        </td>
                                    </tr>

                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_97c0c7fd-9397-49e0-9f6e-3fc7ef1ba7cd">(7FD1,xx01)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_56f5c539-18de-43ec-8a69-5cd024f715a2">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cb17434a-bb39-47dc-bab8-8675bf60dea7">OB</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_22444379-a313-4ace-8657-81836a5e4d81">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_356a0c7b-6df1-415c-aa7c-1d3c237d2957">Acoustic Image and Footer Data</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_43f8de9b-0321-4672-8582-742a0e7c6854">(7FD1,xx09)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_50f76633-6253-4077-a86f-df9d2b8c0dd3">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_84d0f063-bc77-4280-a8c1-272da91bbf51">UI</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_54341b8d-daf3-4427-ae8d-070157d48be4">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_cb212b98-a3c5-491a-a674-65a04f25dd05">Volume Version ID</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_bbf00504-5548-4969-8b3f-9b837cd8e2f8">(7FD1,xx10)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b51fc6d2-03fc-4a1f-9cfe-34308311e91d">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_da270b1a-ff73-49df-a1ad-dc3d27f10a2d">OB</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d54d8741-f98d-42a0-bb00-9695d63b30be">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c6532cb1-5452-4504-b3e0-c4d2cc4dac3b">Volume Payload</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_06ace8e1-8efe-4b9c-8aad-dc8683a5f517">(7FD1,xx11)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_87c74885-1408-49f1-9647-a1d26ab0e195">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_97c63adb-e45b-472d-8e26-dde438494482">OB</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_33e1a752-1ad1-4914-be6b-2819a420cb49">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_27fb7d32-83b5-465f-9eac-7bfcbfe80300">After Payload</para>
                                        </td>
                                    </tr>

                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5b898e63-2202-4277-8af7-cb6f8ff663a1">(7FD1,xx01)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b8711107-33e3-40a4-9e86-5c295902f747">SIEMENS SYNGO ULTRA-SOUND TOYON DATA STREAMING</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_eeb92f16-c9ae-4ce5-bad4-46fe9270056d">OB</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_672f2697-32f2-4664-8ada-9c9006a9e3e5">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_882818ac-f142-40d0-9d98-910eef6bbff3">Padding</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9274af25-1a22-4df2-8b37-528f1c5f0491">(7FD1,xx09)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_73856fa9-62c5-43ce-983f-d0c9d725c836">SIEMENS SYNGO ULTRA-SOUND TOYON DATA STREAMING</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5d74d7fe-2a8e-4427-a6d6-809d58dd2503">UI</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_fe5e6eda-b6d9-48f3-b059-c38859972d62">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f4520330-a971-4723-9a7d-e17b98c411fd">Version ID</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e6079ea2-7698-44c9-9f5c-81a40ee1e992">(7FD1,xx10)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b75bda96-5d50-49a1-bbf5-c078b90f4146">SIEMENS SYNGO ULTRA-SOUND TOYON DATA STREAMING</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2ee6b51e-6e3d-42e3-9180-e5718cac8917">OB</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6353e615-144d-4dd0-9592-4852fe3de6b0">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_05845f3c-db32-448d-9084-177a67f9fca3">Volume Payload</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_64d409e9-e051-4d34-af2c-f7f0d1d2491f">(7FD1,xx11)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e83eb31b-1f0c-4ff8-9350-2ba903cc6167">SIEMENS SYNGO ULTRA-SOUND TOYON DATA STREAMING</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e08e451f-75ab-4ab4-b906-82b90d1bb593">OB</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4256fd4e-fc40-4053-90de-8f4395d321c9">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_fa75bbb7-0318-4f77-900f-875393f939b8">After Payload</para>
                                        </td>
                                    </tr>
                                </tbody>
                            </table>
                        </listitem>
                        <listitem>
                            <para xml:id="para_940fd19f-fdf0-4f34-bc15-04ab81391520">One approach to retaining Private Attributes safely, either when the VR is encoded explicitly or known from a data dictionary (such as may be derived from published DICOM Conformance Statements or previously encountered instances, perhaps by adaptively extending the data dictionary as new explicit VR instances are received), is to retain those Attributes that are numeric only. For example, one might retain US, SS, UL, SS, FL and FD binary Values, and IS and DS string Values that contain only valid numeric characters. One might assume that other string Value Representations are unsafe in the absence of definite confirmation from the vendor to the contrary; code strings (CS) may be an exception. Bulk binary data in OB Value representations is particularly unsafe, and may often contain entire proprietary format headers in binary or text or XML form that includes the patient's name and other identifying
                                information.</para>
                        </listitem>
                    </orderedlist>
                </note>
                <para xml:id="para_74598302-fb52-4831-9a57-fa49e4698746">The safe Private Attributes that are retained shall be described in the Conformance Statement.</para>
            </section>
            <section label="E.3.11" status="3" xml:id="sect_E.3.11">
                <title>Retain Institution Identity Option</title>
                <para xml:id="para_6ad81aa8-3124-4ae1-b804-39d00f2d287f">Information about the identity of the institution where the acquisition was performed is recognized as having a potential for leakage of identity because it may constrain the number of possible individuals that could be the imaging subject, though only if there is access to other information about the individuals concerned to match it against.</para>
                <para xml:id="para_f6d222f6-c1cc-4af6-ae33-c9b0a1f7306b">However, there are applications that require such institution information to perform the analysis or interpretation. There may be a need to maintain a record of the institution for regulatory or registry purposes, yet the acquisition site may not maintain an adequate electronic audit trail.</para>
                <para xml:id="para_00ca9c5a-ce04-4906-ae1f-920d2e0c2c40">When this Option is specified in addition to the Basic Application Level Confidentiality Profile, information about the identity of the institution in the Attributes shall be retained, as described in <xref linkend="table_E.1-1" xrefstyle="select: label"/>.</para>
            </section>
        </section>
    </chapter>
<chapter label="F" status="1" xml:id="chapter_F">
    <title>Network Address Management Profiles</title>
  
  <section label="F.1" status="2" xml:id="sect_F.1">
    <title>Basic Network Address Management Profile</title>
  
  <para xml:id="para_99b584eb-26ed-4f48-8ba4-2f1894aedd53">The Basic Network Address Management Profile utilizes DHCP to provide services to assign and manage IP parameters for machines remotely. The DHCP server is manually configured to establish the rules for assigning IP addresses to machines. The rules may be explicit machine by machine assignments and may be assignment of a block of IP addresses to be assigned dynamically as machines are attached and removed from the network. The DHCP client can obtain its IP address and a variety of related parameters such as NTP server address from the DHCP server during startup. The DHCP server may dynamically update the DNS server with new relationships between IP addresses and DNS hostnames.</para>
  <para xml:id="para_71f90796-664f-4abc-86aa-6fb816abc073">The DNS Client can obtain the IP number for another host by giving the DNS hostname to a DNS Server and receive the IP number in response. This transaction may be used in other profiles or in implementations that do not conform to the Basic Network Address Management Profile.</para>
  <para xml:id="para_0d4cc371-566c-4b74-9ab3-08c6be7e87a4">The Basic Network Address Management Profile applies to the actors DHCP Server, DHCP Client, DNS Server, and DNS Client. The mandatory and optional transactions are described in the table and sections below.</para>
    <table frame="box" label="F.1-1" rules="all" xml:id="table_F.1-1">
    <caption>Basic Network Address Management Profile</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_aa6b0244-a474-4b9f-9300-a53fbb5204ce">Actor</para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_f0cf49e1-5e42-4a73-8e77-2911a2fb9196">Transaction</para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_0856004a-2591-45a1-b155-4a80061f0d35">Optionality</para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_551b766e-9c74-4eaa-9464-ac3b98c9375b">Section</para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0713b13d-6775-4e0e-b7a7-bf042d77742d">DHCP Server</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a9fed0f8-5362-40e7-8978-0da6d49a69a0">Configure DHCP Server</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_262a8eea-8a36-489f-aa39-c7fa14c5890d">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_64ccbdb5-af7b-4bba-8528-731e6b8cdffb">F.1.2</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1"/>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9bd27540-80de-46fd-9a9d-e1ca98aea2b6">Find and Use DHCP Server</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5e0a73ed-7432-4e5b-b944-c9faa1519e3a">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8e68d931-a6bd-4100-94c5-34ec420a469c">F.1.3</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1"/>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_60648266-17fd-409a-a1b1-ecad1c5a7955">Maintain Lease</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5eec8c42-99ff-44bf-bfe9-76699d6af10c">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_295a10ca-bb5f-47af-8015-91d297184d42">F.1.4</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1"/>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_58e07568-2bed-4d05-8d9a-6872683e228d">Resolve Hostname</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1e52e28e-6367-4935-93b6-f9cfb7bbcadb">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_54b76afd-0591-4866-a2ae-b233797e28b4">F.1.1</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1"/>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5a9b0d06-7ee0-4ace-983f-0bdc8a8dc503">DDNS Coordination</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e4295cd7-04bb-411e-bfd7-f614b674b8d2">O</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2c7b2898-2279-49f5-a0ce-9074a1ef137f">F.1.5</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_80d6dea2-3876-4719-8cf7-0a00d95963aa">DHCP Client</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_dcb13345-fbad-4b97-9488-9eca0bf47ff3">Find and Use DHCP Server</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f7ffdbae-ac87-497e-8297-f593b6064843">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9280c783-d4a0-4239-b0f9-d09e0a3bab99">F.1.3</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1"/>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_4fe3e963-b808-4f5a-adfb-62c75e717238">Maintain Lease</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_830a5472-bdd0-43bf-b9a9-8a71297d86e4">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a76aac4c-bef6-44ac-b450-0e6185981ad7">F.1.4</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_07dcd765-0ae2-42bd-bb0a-57794597837a">DNS Server</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_bfa26e3f-0648-4c58-862f-3b46026e5bc6">DDNS Coordination</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_bf58b8e3-3993-416d-a5ae-403f02004e5a">O</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ac17ba54-8f02-4d37-91f4-f62beb70a5d2">F.1.5</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1"/>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a4d84e75-5b66-4428-ae7d-1645c0fab0b3">Resolve Hostname</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_65c48d30-a14d-448a-b565-0f916de53c2e">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_675195a4-6613-4acb-a04b-ef02ae922603">F.1.1</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_572e03b1-b04c-4091-842e-81c52c1f47a1">DNS Client</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3e805b7d-5121-45b8-8efc-e73a9337b81b">Resolve Hostname</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_65b24bea-5615-4df2-a9a9-18e21d9fae19">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_664fc116-6c09-4626-b2d5-2857b1e4e0bb">F.1.1</para>
      </td>
    </tr>
  </tbody>
  </table>
  <section label="F.1.1" status="3" xml:id="sect_F.1.1">
    <title>Resolve Hostname</title>
  
  <section label="F.1.1.1" status="4" xml:id="sect_F.1.1.1">
    <title>Scope</title>
  
  <para xml:id="para_597641a0-b913-4021-8dae-f32ef17ee8b4">The DNS Client can obtain the IP number for a host by giving the DNS hostname to a DNS Server and receive the IP number in response.</para>
  </section>
<section label="F.1.1.2" status="4" xml:id="sect_F.1.1.2">
    <title>Use Case Roles</title>
  
  <para xml:id="para_279bb6df-3201-4df3-859e-e50c9823da33">
  <figure label="F.1-1" pgwide="1" xml:id="figure_F.1-1">
    <title>Resolve Hostname</title>
    <mediaobject>
      <imageobject>
        <imagedata fileref="figures/PS3.15_F.1-1.svg"/>
        <!--<imagedata fileref="part15_fromword_files/image004.png"/>-->
      </imageobject>
    </mediaobject>
  </figure>
</para>
  <variablelist>
    <varlistentry>
<term>Actor:</term>
<listitem>
<para xml:id="para_f7bc052d-7008-441a-885d-4e8d8de85a29">DNS Client</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>Role:</term>
<listitem>
<para xml:id="para_b169625e-7e6c-4238-802f-c819de3a4a58">Needs IP address, has the DNS Hostname</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>Actor:</term>
<listitem>
<para xml:id="para_089f683d-9cc9-423e-b45e-91aca91f7328">DNS Server</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>Role:</term>
<listitem>
<para xml:id="para_408b55ad-85c3-4166-9d38-7d3623927e82">Provides current IP address when given the DNS Hostname</para>
</listitem>
</varlistentry>
  </variablelist>
</section>
<section label="F.1.1.3" status="4" xml:id="sect_F.1.1.3">
    <title>Referenced Standards</title>
  
  <para xml:id="para_092507ea-dd1d-48b7-bd61-696880908b13">The standards and their relationships for the family of DNS protocols are shown in <xref linkend="figure_F.1-2" xrefstyle="select: label"/>. The details of transactions, transaction diagrams, etc. are contained within the referenced RFCs.</para>
  <para xml:id="para_5b42b970-7023-48a0-adc5-b3c8ec4fbf49">
  <figure label="F.1-2" pgwide="1" xml:id="figure_F.1-2">
    <title>DNS Referenced Standards</title>
    <mediaobject>
      <imageobject>
        <imagedata fileref="figures/PS3.15_F.1-2.svg"/>
        <!--<imagedata fileref="part15_fromword_files/image006.png"/>-->
      </imageobject>
    </mediaobject>
  </figure>
</para>
  </section>
<section label="F.1.1.4" status="4" xml:id="sect_F.1.1.4">
    <title>DNS Security Considerations (Informative)</title>
  
  <para xml:id="para_422943ef-4872-4adb-9e86-82e7bfbaf869">The issue of security is under active development by the Internet Engineering Task Force and its various working groups. The security related RFCs and drafts are identified in <xref linkend="figure_F.1-2" xrefstyle="select: label"/>. Some of these are completed. Others are still in the draft stage. The Basic Network Address Management Profile does not include specific requirements for support of DNS security extensions by the DNS Client.</para>
  <para xml:id="para_e9db13e7-cf08-4723-8eef-273b9f111d99">The Basic Network Address Management profile should not be used outside a secured environment. At a minimum there should be:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_7bc15286-0390-44c5-8484-182ee894dcbd">Firewall or router protections to ensure that only approved external hosts are used for DNS services.</para>
</listitem>
<listitem>
<para xml:id="para_0167184b-efc1-44d6-9a66-4a5a3c7ed408">Agreements for VPN and other access should require that DNS clients use only approved DNS servers over the VPN.</para>
</listitem>
</orderedlist>
  <para xml:id="para_e81f669b-7304-4678-a402-10c7b129c519">Other network security procedures such as automated intrusion detection may be appropriate in some environments. Security features beyond this minimum should be established by the local security policy and are beyond the scope of DICOM.</para>
  <para xml:id="para_d0577d90-7b86-4ce3-9f0f-0676e3e53a61">The purpose of the selected security is to limit the scope of the threat to insider attacks. The DNS system discloses only hostnames and IP addresses, so there is little concern about eavesdropping. The protections are to limit the exposure to denial of service attacks by counterfeit servers or clients.</para>
  </section>
<section label="F.1.1.5" status="4" xml:id="sect_F.1.1.5">
    <title>DNS Implementation Considerations (Informative)</title>
  
  <para xml:id="para_2a2e322b-fee6-440d-a86d-6bf7e6f1c4e9">Client caches may cause confusion during updates. Many DNS clients check for DNS updates very infrequently and might not reflect DNS changes for hours or days. Manual steps may be needed to trigger immediate updates. Details for controls of cache and update vary for different DNS clients and DNS servers, but DNS caching and update propagation delays are significant factors and implementations have mechanisms to manage these issues.</para>
  <para xml:id="para_e3674d11-64b6-4df9-8cbf-1b833a6797b9">DNS Server failure management should be considered. Redundant servers and fallback host files are examples of possible error management tools.</para>
  </section>
<section label="F.1.1.6" status="4" xml:id="sect_F.1.1.6">
    <title>Support For Service Discovery</title>
  
  <para xml:id="para_5bb36c1e-1948-43f2-87d5-82cb69f4d124">The DNS server may provide additional optional information in support of configuration management. See <xref linkend="sect_H.2" xrefstyle="select: label"/> for the specification of this information and additional RFCs to be supported.</para>
  </section>
</section>
<section label="F.1.2" status="3" xml:id="sect_F.1.2">
    <title>Configure DHCPserver</title>
  
  <section label="F.1.2.1" status="4" xml:id="sect_F.1.2.1">
    <title>Scope</title>
  
  <para xml:id="para_ace7d64b-1fa0-44cf-8c87-318c5c1fa55d">The DHCP server shall be configurable by site administration so that</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_c1634ed3-7a37-4c4b-96f7-2cc3f910c69f">DHCP clients can be added and removed.</para>
</listitem>
<listitem>
<para xml:id="para_3730854b-ab41-4f5f-9173-50c03e0517bd">DHCP clients configurations can be modified to set values for attributes used in later transactions.</para>
</listitem>
<listitem>
<para xml:id="para_90e93945-d339-40cb-afff-2e1b2f8176fc">pre-allocation of fixed IP addresses for DHCP clients is supported</para>
</listitem>
</orderedlist>
  <para xml:id="para_c1c78d1b-5b0a-4ec9-813a-2aeea69949fa">This Standard does not specify how this configuration is to be performed.</para>
  <note>
    <para xml:id="para_e5e9557d-1fd8-48e7-917a-b67664a651ce">Most DHCP servers support the pre-allocation of fixed IP addresses to simplify the transition process for legacy systems. This permits a particular device to switch to DHCP while retaining the previously assigned IP address. This enables the use of a central site management of IP addresses without breaking compatibility with older systems that require fixed IP addresses.</para>
  </note>
  </section>
<section label="F.1.2.2" status="4" xml:id="sect_F.1.2.2">
    <title>Use Case Roles</title>
  
  <para xml:id="para_e3a68835-1e16-4387-9256-14d160534306">
  <figure label="F.1-3" pgwide="1" xml:id="figure_F.1-3">
    <title>Configure DHCP Server</title>
    <mediaobject>
      <imageobject>
        <imagedata fileref="figures/PS3.15_F.1-3.svg"/>
        <!--<imagedata fileref="part15_fromword_files/image008.png"/>-->
      </imageobject>
    </mediaobject>
  </figure>
</para>
  <variablelist>
    <varlistentry>
<term>Actor:</term>
<listitem>
<para xml:id="para_2eae2a15-1ec2-4cbf-ab4c-a4e20e12dafb">DHCP Server</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>Role:</term>
<listitem>
<para xml:id="para_1b3e179f-d00f-41ae-946d-9543b80bacb8">Maintains internal configuration files.</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>Actor:</term>
<listitem>
<para xml:id="para_55d4c509-a7d6-45a2-be0a-ea01ca0af62c">Site Administrator</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>Role:</term>
<listitem>
<para xml:id="para_6fa712a8-7113-4fe4-b32e-8c37f80f40ff">Updates configuration information to add, modify, and remove descriptions of clients and servers.</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>Actor:</term>
<listitem>
<para xml:id="para_a8658cef-0ae1-4088-9b1c-682721dd6cc1">Service Staff</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>Role:</term>
<listitem>
<para xml:id="para_613b24e8-a8b5-447d-9f3d-d545332ccb47">Provides initial configuration requirements for many devices when installing a new network, and for individual devices when installing or modifying a single device.</para>
</listitem>
</varlistentry>
  </variablelist>
</section>
<section label="F.1.2.3" status="4" xml:id="sect_F.1.2.3">
    <title>Referenced Standards</title>
  
  <para xml:id="para_df213348-62c2-47db-9d28-834210eeedc9">None</para>
  </section>
</section>
<section label="F.1.3" status="3" xml:id="sect_F.1.3">
    <title>Find and Use DHCP Server</title>
  
  <section label="F.1.3.1" status="4" xml:id="sect_F.1.3.1">
    <title>Scope</title>
  
  <para xml:id="para_77006ee2-dcd6-414c-8962-e3abfe55c6ed">This is the support for the normal startup process. The DHCP client system boots up, and very early in the booting process it finds DHCP servers, selects one of the DHCP servers to be its server, queries that server to obtain a variety of information, and continues DHCP client self-configuration using the results of that query. DHCP servers may optionally provide a variety of information, such as server locations, normal routes. This transaction identifies what information shall be provided by a compliant DHCP server, and identifies what information shall be requested by a compliant DHCP client. A compliant DHCP server in not required to provide this optional information.</para>
  </section>
<section label="F.1.3.2" status="4" xml:id="sect_F.1.3.2">
    <title>Use Case Roles</title>
  
  <para xml:id="para_65b6de3f-a64b-48bd-b84e-8ee9a023dd46">
  <figure label="F.1-4" pgwide="1" xml:id="figure_F.1-4">
    <title>Find and Use DHCP Server</title>
    <mediaobject>
      <imageobject>
        <imagedata fileref="figures/PS3.15_F.1-4.svg"/>
        <!--<imagedata fileref="part15_fromword_files/image010.png"/>-->
      </imageobject>
    </mediaobject>
  </figure>
</para>
  <variablelist>
    <varlistentry>
<term>Actor:</term>
<listitem>
<para xml:id="para_f80c2e93-c7d4-4232-97b9-d70c29bb6678">DHCP Server</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>Role:</term>
<listitem>
<para xml:id="para_82d613ea-abe3-4d29-8345-e610e57a2578">Responds to DHCP acquisition queries. Multiple actors may exist. The DHCP client will select one.</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>Actor:</term>
<listitem>
<para xml:id="para_c695e78c-e5a7-440e-bf9b-33c758c64843">DHCP client</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>Role:</term>
<listitem>
<para xml:id="para_b2ac2a95-e01d-464e-a6be-bfe780b17a18">Queries for DHCP Servers. Selects one responding server.</para>
</listitem>
</varlistentry>
  </variablelist>
</section>
<section label="F.1.3.3" status="4" xml:id="sect_F.1.3.3">
    <title>Referenced Standards</title>
  
  <para xml:id="para_6b738506-a7ea-4629-bcee-f9a3e25a4287">
<xref linkend="biblio_RFC_2131"/> DHCP Protocol</para>
  <para xml:id="para_3f5e16cd-a076-4e88-bd2e-fba21eed0084">
<xref linkend="biblio_RFC_2132"/> DHCP Options</para>
  <para xml:id="para_f909057c-d781-46b0-b499-c2cb5a305647">
<xref linkend="biblio_RFC_2563"/> Auto Configuration control</para>
  </section>
<section label="F.1.3.4" status="4" xml:id="sect_F.1.3.4">
    <title>Interaction Diagram</title>
  
  <para xml:id="para_7c061ec3-5d7a-4936-91b9-b3b35bc656c5">
  <figure label="F.1-5" pgwide="1" xml:id="figure_F.1-5">
    <title>DHCP Interactions</title>
    <mediaobject>
      <imageobject>
        <imagedata fileref="figures/PS3.15_F.1-5.svg"/>
        <!--<imagedata fileref="part15_fromword_files/image012.png"/>-->
      </imageobject>
    </mediaobject>
  </figure>
</para>
  <para xml:id="para_cdcfd115-d2ac-4c7e-a777-14aff4db98b5">The DHCP client shall comply with <xref linkend="biblio_RFC_2131"/> (DHCP Protocol), <xref linkend="biblio_RFC_2132"/> (DHCP Options), <xref linkend="biblio_RFC_2563"/> (Auto Configuration Control), and their referenced RFCs.</para>
  <para xml:id="para_7014e8c8-c024-49e7-9ce3-b38358e21ca7">The DHCP client shall query for available DHCP servers. It shall select the DHCP server to use.</para>
  <para xml:id="para_6dc42b56-361f-4268-8966-057d2510bf7e">The DHCP client shall query for an IP assignment. The DHCP Server shall determine the IP parameters in accordance with the current DHCP configuration, establish a lease for these parameters, and respond with this information. (See below for lease maintenance and expiration.) The DHCP client shall apply these parameters to the TCP/IP stack. The DHCP client shall establish internal lease maintenance activities.</para>
  <para xml:id="para_27145fe0-f084-4b94-b0d9-54ca7df272f7">The DHCP client shall query for the optional information listed in <xref linkend="table_F.1-2" xrefstyle="select: label"/> when required by additional profiles used by the client system. If the DHCP server does not provide this information, the default values shall be used by the DHCP client.</para>
    <table frame="box" label="F.1-2" rules="all" xml:id="table_F.1-2">
    <caption>DHCP Parameters</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_e8123fe2-21a0-454d-b9c1-677768313553">DHCP Option</para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_9aac011f-945d-4454-9319-503d7edb5a07">Description</para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_5a55d124-d6ea-4d9f-bd66-043023233458">Default</para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_484bb3bf-b796-49a2-abbb-62dbca134936">NTP</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_96eb49fc-71a7-4ea0-9d56-399cfdea3139">List of NTP servers</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_42d827e6-75fa-49a9-8712-29c91859b8ad">Empty list</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c9f9383d-906b-4e8f-b146-00e21c95171e">DNS</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_122cb38e-05aa-4969-9c2e-954c18536a46">List of DNS servers</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_cdbfa721-b813-4156-ab59-61c299f8d801">Empty list</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_cc21d021-0384-42ae-80a6-97e7ba4d9c94">Router</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d3395f9b-6cda-4c46-b289-ad838cb6ef0a">Default router</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_caa6b7e4-20c3-49ae-8da7-9b49c30a4ec4">Empty list</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b19fb802-23c0-4854-a5ca-ed3ca35ef031">Static routes</para>
      </td>
      <td align="center" colspan="1" rowspan="1"/>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_300766d1-39dd-459b-816e-7aabe2b5968b">Nil</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3148087c-acc7-4922-bac3-3d604aeb5c54">Hostname</para>
      </td>
      <td align="center" colspan="1" rowspan="1"/>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3dada236-24bf-4f94-81af-6dce95f62074">Requested machine name</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a9cfc9b6-b92c-4804-bfb4-1aa4c23d307c">Domain name</para>
      </td>
      <td align="center" colspan="1" rowspan="1"/>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_7526239c-f540-4c93-9e15-6301f5a0f985">Nil</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b016ee91-924c-4ecb-bc04-bda864a0dded">Subnet mask</para>
      </td>
      <td align="center" colspan="1" rowspan="1"/>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_38d21a80-fc83-44ce-bfcf-08ef5e8470a2">Derived from network value</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_cf5647be-9938-4ec0-b7a4-5ce0649b5ff4">Broadcast address</para>
      </td>
      <td align="center" colspan="1" rowspan="1"/>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_eac3a598-2442-410b-8fb3-054a9034db45">Derived from network value</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_01b1081e-f3a6-4961-969e-4ee48dc01eb8">Default router</para>
      </td>
      <td align="center" colspan="1" rowspan="1"/>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_97b7cd07-630f-4446-a7ef-9e4bf350e3dd">Nil</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0a1d4586-6dd4-47a9-8d18-2b22e13fd1d9">Time offset</para>
      </td>
      <td align="center" colspan="1" rowspan="1"/>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_07ef4187-0e98-45ff-86c4-35793a3612e6">Site configurable</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_30096b94-5693-408f-a197-7b6aaac6d1de">MTU</para>
      </td>
      <td align="center" colspan="1" rowspan="1"/>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c1ff7be7-e0b5-4f6c-874f-ebeb67aef893">Hardware dependent</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_cc1c3bcf-678d-49b9-84f7-06b862e477af">Auto-IP permission</para>
      </td>
      <td align="center" colspan="1" rowspan="1"/>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_ec7ccdc2-09ae-4542-8cb2-63268e578e9a">From NVRAM</para>
      </td>
    </tr>
  </tbody>
  </table>
  <para xml:id="para_50877d5a-ae4d-42c4-9a21-ca1741a84c83">The DHCP client shall make this information available for other actors within the DHCP client machine.</para>
  </section>
</section>
<section label="F.1.4" status="3" xml:id="sect_F.1.4">
    <title>Maintain Lease</title>
  
  <section label="F.1.4.1" status="4" xml:id="sect_F.1.4.1">
    <title>Scope</title>
  
  <para xml:id="para_4a2da825-02af-4800-a042-6e55515c8b95">The DHCP client normally maintains the IP lease in compliance with the RFCs. Sometimes the server will not renew the lease. Non-renewal is usually part of network service operations. The loss of the IP lease requires connections using that IP address to cease.</para>
  </section>
<section label="F.1.4.2" status="4" xml:id="sect_F.1.4.2">
    <title>Use Case Roles</title>
  
  <para xml:id="para_489c40cc-5322-4289-92d4-3b080548ed7e">
  <figure label="F.1-6" pgwide="1" xml:id="figure_F.1-6">
    <title>Maintain Lease</title>
    <mediaobject>
      <imageobject>
        <imagedata fileref="figures/PS3.15_F.1-6.svg"/>
        <!--<imagedata fileref="part15_fromword_files/image014.png"/>-->
      </imageobject>
    </mediaobject>
  </figure>
</para>
  <variablelist>
    <varlistentry>
<term>Actor:</term>
<listitem>
<para xml:id="para_cf8d521f-5ada-41b1-868c-cbbd732a9308">DHCP client</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>Role:</term>
<listitem>
<para xml:id="para_3dcb3b16-e480-4403-8048-a87b0143d77e">Deals with lease renewal and expiration.</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>Actor:</term>
<listitem>
<para xml:id="para_0db52515-254c-43c5-8410-15f4cb7155c4">DHCP Server</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>Role:</term>
<listitem>
<para xml:id="para_40ddce56-1b3b-47e5-b6a4-47a743f08e27">Renewing or deliberately letting leases expire (sometimes done as part of network service operations).</para>
</listitem>
</varlistentry>
  </variablelist>
</section>
<section label="F.1.4.3" status="4" xml:id="sect_F.1.4.3">
    <title>Referenced Standards</title>
  
  <para xml:id="para_ffa844a4-0b19-445d-ba3c-69e0251e36ae">
<xref linkend="biblio_RFC_2131"/> DHCP Protocol</para>
  <para xml:id="para_ebee716b-d0a9-4ded-846b-e9eaddf5da54">
<xref linkend="biblio_RFC_2132"/> DHCP Options</para>
  </section>
<section label="F.1.4.4" status="4" xml:id="sect_F.1.4.4">
    <title>Normal Interaction</title>
  
  <para xml:id="para_e4678ad5-b5e0-4b0c-aa73-384a3905914f">The DHCP client shall maintain a lease on the IP address in accordance with the DHCP protocol as specified in <xref linkend="biblio_RFC_2131"/> and <xref linkend="biblio_RFC_2132"/>. There is a possibility that the DHCP Server may fail, or may choose not to renew the lease.</para>
  <para xml:id="para_df165db7-dbc9-4e5b-89af-73007dea833d">In the event that the DHCP lease expires without being renewed, any still active DICOM connections may be aborted (AP-Abort).</para>
  <note>
    <para xml:id="para_2be61abd-b08b-4a3f-9f7a-42ebf40e9f75">There is usually a period (typically between several minutes and several days) between the request for lease extension and actual expiration of the lease. The application might take advantage of this to perform a graceful association release rather than the abrupt shutdown of an AP-Abort.</para>
  </note>
  </section>
</section>
<section label="F.1.5" status="3" xml:id="sect_F.1.5">
    <title>DDNS Coordination</title>
  
  <section label="F.1.5.1" status="4" xml:id="sect_F.1.5.1">
    <title>Scope</title>
  
  <para xml:id="para_bc387209-ade9-4c28-acf3-bd666c18e3b2">DHCP servers may coordinate their IP and hostname assignments with a DNS server. This permits dynamic assignment of IP addresses without interfering with access to DHCP Clients by other systems. The other systems utilize the agreed hostname (which DHCP can manage and provide to the client) and obtain the current IP address by means of DNS lookup.</para>
      <para xml:id="para_709f1747-b1ff-4495-af66-561479458cda">Dynamic DNS (DDNS) provides the capability to the client to update DNS records hosted on the DNS server. The client can be a DHCP server, Active Directory or LDAP servers, or even an application announcing the systems IP address and optionally any available services.</para>
      <para xml:id="para_3ce0bcc9-63d1-4809-9bde-25bd771b4d15">A DHCP Server complies with this optional part of the Basic Network Address Management Profile if it maintains and updates the relevant DNS entry so as to maintain the hostname and IP relationships in the DNS database when they change.</para>
  </section>
<section label="F.1.5.2" status="4" xml:id="sect_F.1.5.2">
    <title>Use Case Roles</title>
  
  <para xml:id="para_ed9848af-c4b8-42c7-aff5-01e1be4ed4c3">
  <figure label="F.1-7" pgwide="1" xml:id="figure_F.1-7">
    <title>DDNS Coordination</title>
    <mediaobject>
      <imageobject>
        <imagedata fileref="figures/PS3.15_F.1-7.svg"/>
        <!--<imagedata fileref="part15_fromword_files/image016.png"/>-->
      </imageobject>
    </mediaobject>
  </figure>
</para>
  <variablelist>
    <varlistentry>
<term>Actor:</term>
<listitem>
<para xml:id="para_392b7887-17be-4fef-988d-d315124341a5">DHCP Server</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>Role:</term>
<listitem>
<para xml:id="para_136f9a9c-a307-4f4d-a0ca-e17a93c0871d">Responded to DHCP acquisition queries and assigned IP address to client.</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>Actor:</term>
<listitem>
<para xml:id="para_ad37616d-a206-46c6-a882-cc21e09f0922">DNS Server</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>Role:</term>
<listitem>
<para xml:id="para_acd71424-5419-4582-a3f8-1543b76c80d0">Maintains the DNS services for the network.</para>
</listitem>
</varlistentry>
  </variablelist>
</section>
<section label="F.1.5.3" status="4" xml:id="sect_F.1.5.3">
    <title>Referenced Standards</title>
  
  <para xml:id="para_958fff00-ae68-4da0-886b-472c7ec16c2b">
<xref linkend="biblio_RFC_2136"/> Dynamic Updates in the Domain Name System</para>
  </section>
<section label="F.1.5.4" status="4" xml:id="sect_F.1.5.4">
    <title>Basic Course of Events</title>
  
    <para xml:id="para_56ae9536-422c-4501-90cf-c8ce298b7281">The DHCP server assigns an IP address to a DHCP client, then informs the DDNS server that the hostname associated with the DHCP client has been given an assigned IP address.
        The DDNS server updates the DNS database and links the IP address to the hostname. DNS queries for this hostname are directed to the assigned IP address.
        If the assigned IP address changes or expires, the DHCP server informs the DDNS server, which updates the DNS database.</para>
  </section>
</section>
<section label="F.1.6" status="3" xml:id="sect_F.1.6">
    <title>DHCP Security Considerations (Informative)</title>
  
  <para xml:id="para_9bd115ee-3150-42f7-988c-c9475bb92ee3">The Basic Network Address Management Profile Profile has two areas of security concerns:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_18cc71fa-19db-42e4-8b80-e7d27963970c">Protection against denial of service attacks against the DHCP client/server traffic.</para>
</listitem>
<listitem>
<para xml:id="para_4c22cc74-f709-4788-a53a-cedcb74f0bcd">Protection against denial of service attacks against the DHCP server to DDNS server update process.</para>
</listitem>
</orderedlist>
  <para xml:id="para_1fa617f1-f3c1-4ab8-a436-cd6c9e4d00d2">The Basic Network Address Management Profile Profile should not be used outside a secured environment. At a minimum there should be:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_33501129-3860-4ad1-8fbb-ec4d569be174">Firewall and or router protections to ensure that only approved hosts are used for DHCP and DNS services.</para>
</listitem>
<listitem>
<para xml:id="para_96b7ac1d-0a9f-460a-8b1e-8231abab2421">Agreements for VPN and other access should require that DNS clients on the hospital network use only approved DHCP or DNS servers over the VPN.</para>
</listitem>
</orderedlist>
  <para xml:id="para_8b41c04a-c892-4cd1-9293-2acbb4a3ba5b">Other network security procedures such as automated intrusion detection may be appropriate in some environments. Security features beyond this minimum should be established by the local security policy and are beyond the scope of DICOM.</para>
  <para xml:id="para_bf98d134-ff34-49ad-9e86-611ec396563e">The purpose of the selected security is to limit the scope of the threat to insider attacks. The DHCP and DNS systems disclose only hostnames and IP addresses, so there is little concern about eavesdropping. The protections are to limit the exposure to denial of service attacks by counterfeit servers or clients. The specific DNS security extensions are described in <xref linkend="sect_F.1.1.4" xrefstyle="select: label"/>. This profile does not utilize the DHCP security extensions because they provide very limited added security and the attacks are insider denial of service attacks. Intrusion detection and other network level protection mechanisms are the most effective next level of protections for the DHCP process.</para>
  <para xml:id="para_642e0ac4-0565-49af-abbe-ee67e5576f9e">The DNS update is optional in this profile to accommodate the possibility that the DHCP server and DNS server cannot reach a mutually acceptable security process. Support of this option may require support of the DNS security protocols that are in the process of development. See <xref linkend="sect_F.1.1.4" xrefstyle="select: label"/> for a discussion of the DNS security profile standards and drafts.</para>
  </section>
<section label="F.1.7" status="3" xml:id="sect_F.1.7">
    <title>DHCP Implementation Considerations (Informative)</title>
  
  <para xml:id="para_3f6f72a3-0a32-4b0b-af36-4a66ade3a306">The DHCP configuration file can be a very useful form of documentation for the local network hardware configuration. It can be prepared in advance for new installations and updated as clients are added. Including information for all machines, including those that do not utilize DHCP, avoids accidental IP address conflicts and similar errors.</para>
  <para xml:id="para_50cdba9b-dc48-4a97-bd15-7125489f8a2f">Most DHCP servers have a configuration capability that permits control of the IP address and other information provided to the client. These controls can pre-allocate a specific IP address, etc. to a machine based on the requested machine name or MAC address. These pre-allocated IP addresses then ensure that these specific machines are always assigned the same IP address. Legacy systems that do not utilize DNS can continue to use fixed tables with IP addresses when the DHCP server has pre-allocated the IP addresses for those services.</para>
  </section>
<section label="F.1.8" status="3" xml:id="sect_F.1.8">
    <title>Conformance</title>
  
    <para xml:id="para_8750df41-100a-4031-97b4-610915f2b646">An implementation that supports this profile shall state in its Conformance Statement whether it supports DHCP as DHCP Client or DHCP Server.</para>
    <para xml:id="para_61768d52-6395-4c40-b592-8b3bf0938f85">An implementation that supports this profile as a DHCP Client shall state in its Conformance Statement how the DHCP Server is discovered (see <xref linkend="sect_F.1.3" xrefstyle="select: label"/>).</para>
    <para xml:id="para_38a928ab-986d-4cab-b037-38ac3a737af1">An implementation that supports this profile shall state in its Conformance Statement whether it supports DNSSEC <xref linkend="biblio_RFC_4033"/> <xref linkend="biblio_RFC_4034"/> <xref linkend="biblio_RFC_4035"/> for the interactions described in this profile, in which case either the options supported shall be stated or a reference provided to the DNSSEC support for this product.</para>
    
  </section>
</section>
</chapter>
<chapter label="G" status="1" xml:id="chapter_G">
            <title>Time Synchronization Profiles</title>
            
            <section label="G.1" status="2" xml:id="sect_G.1">
                <title>Basic Time Synchronization Profile</title>
                
                <para xml:id="para_b121cf7b-9b61-4f90-b52e-6991cbf4e735">The Basic Time Synchronization Profile defines services to synchronize the clocks on multiple computers. It employs the Network Time Protocol (NTP) services that have been used for this purpose by many other disciplines. NTP permits synchronization to a local server that provides a local time source, and synchronization to a variety of external time services. The accuracy and precision controls are not explicitly part of the protocol. They are determined in large part by the selection of clock hardware and network topology.</para>
                <para xml:id="para_e0f0d1cb-6fd1-49f3-a254-bf3093b57cdb">An extensive discussion of implementation strategies for NTP can be found at http://www.ntp.org.</para>
                <para xml:id="para_dac1c42a-4b39-4aa9-a1c9-ac5bae887dcc">The Basic Time Synchronization Profile applies to the actors DHCP Client, DHCP Server, SNTP Client, NTP Client and NTP Server. The mandatory and optional transactions are described in the table and sections below.</para>
                <table frame="box" label="G.1-1" rules="all" xml:id="table_G.1-1">
                    <caption>Basic Time Synchronization Profile</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aae02944-2082-42a2-accc-a235a000c6d5">Actor</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9f691895-f654-405a-8c55-60a81376e995">Transaction</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a5650fb8-5eb9-4986-bf11-7c8748e32753">Optionality</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4e42325b-ceb0-44f5-ac61-ee1ab693d955">Section</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72140d49-adf8-427a-846a-90e0a9e001ad">NTP Server</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f01c2603-063a-478d-a97d-8c7f6f2ccb9c">Maintain Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_725e96c2-b109-4a02-bb0a-4898c6871d3f">M</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b9c5b34f-d633-40be-8b94-d057d810837b">G.1.2</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0c67fd3-b6de-450c-8c11-1f4580c28b07">Find NTP Servers</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1f0abdff-d6db-46f7-9a36-1949b0cb147d">O</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f9d91707-8d8a-433c-915b-3ea367ca33ac">G.1.1</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_474c1e21-af9f-4636-a042-cdfa4dbe1e2a">NTP Client</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f06444b-dfd6-44b4-b0f4-d7a876e0b66e">Maintain Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_476aa4dd-a0cb-4c17-a72e-be36904a18bd">M</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f9fb9ebc-22eb-4377-ba1f-2c87957297db">G.1.2</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="center" colspan="1" rowspan="1"/>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7780ff97-0c9c-405b-8699-f47d92548d3a">Find NTP Servers</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9427eb69-7484-4cee-b1ed-f1adaff8d89d">O</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d43356bf-571e-4ed2-8294-dca5f1c364d9">G.1.1</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_283efee2-b91a-44d4-8da7-f2496bb819f2">SNTP Client</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c62d63cd-c936-4e7a-9a1b-5600139dad0f">Maintain Time</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2e970f4f-ec75-40f2-bb3a-024f6907cf38">M</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cb2f1bcd-60b5-444e-9d9a-602fb6f6562b">G.1.2</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc1373c0-de78-4b20-9f0c-6a8ca99fe887">DHCP Server</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8eae1598-c244-4a18-bd68-0bf21a8e583a">Find NTP Servers</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_31a09a0a-ff99-4096-a20a-2259247d9b75">O</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3a830935-e868-47d6-94b9-6f113d499c7b">G.1.1</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_05d02498-eab3-4123-81b8-9dc7b2e8ed3d">DCHP Client</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fcf030fe-4244-4518-ab8e-749f91ad09db">Find NTP Servers</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ffd3657a-b678-42bd-8d24-87c110d56a14">M</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_44751e2b-7f8d-4f2f-89a6-03e792025473">G.1.1</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <section label="G.1.1" status="3" xml:id="sect_G.1.1">
                    <title>Find NTP Servers</title>
                    
                    <para xml:id="para_b9d07d59-3176-4aa3-83bf-5f0cd9c774b3">The optional NTP protocol elements for NTP autoconfiguration and NTP autodiscovery can significantly simplify installation. The NTP specification for these is defined such that they are truly optional for both client and server. In the event that a client cannot find an NTP server automatically using these services, it can use the DHCP optional information or manually configured information to find a server. Support for these services is recommended but not mandatory.</para>
                    <para xml:id="para_6cf12e12-9a96-46ed-bfe5-306ca292736e">This transaction exists primarily as a means of documenting whether particular models of equipment support the automatic discovery. This lets installation and operation plan their DHCP and equipment installation procedures in advance.</para>
                    <section label="G.1.1.1" status="4" xml:id="sect_G.1.1.1">
                        <title>Scope</title>
                        
                        <para xml:id="para_14469ea4-9871-4e67-820f-c724c7a4a759">This applies to any client that needs the correct time, or that needs to have its time stamps synchronized with those of another system. The accuracy of synchronization is determined by details of the configuration and implementation of the network and NTP servers at any specific site.</para>
                        <para xml:id="para_c0bc2b47-7cb8-4ebe-ac72-ce4c89f7b304">Both the NTP and SNTP clients shall utilize the NTP server information if it is provided by DHCP and NTP services have not been found using autodiscovery. Manual configuration shall be provided as a backup. Autodiscovery or DHCP are preferred.</para>
                    </section>
                    <section label="G.1.1.2" status="4" xml:id="sect_G.1.1.2">
                        <title>Use Case Roles</title>
                        
                        <para xml:id="para_4c45d72b-8c53-4732-9da2-5faa8c467fc2">
                            <figure label="G.1-1" pgwide="1" xml:id="figure_G.1-1">
                                <title>Find NTP Servers</title>
                                <mediaobject>
                                    <imageobject>
                                        <imagedata fileref="figures/PS3.15_G.1-1.svg"/>
                                        <!--<imagedata fileref="part15_fromword_files/image018.png"/>-->
                                    </imageobject>
                                </mediaobject>
                            </figure>
                        </para>
                        <variablelist>
                            <varlistentry>
                                <term>DHCP Server</term>
                                <listitem>
                                    <para xml:id="para_110d7468-40d9-4fc7-9454-2468b6d694ff">Provides UTC offset, provides list of NTP servers</para>
                                </listitem>
                            </varlistentry>
                            <varlistentry>
                                <term>DHCP Client</term>
                                <listitem>
                                    <para xml:id="para_d589744b-cce9-4980-83f9-5a58284d05de">Receives UTC offset and list of NTP servers</para>
                                </listitem>
                            </varlistentry>
                            <varlistentry>
                                <term>NTP Client</term>
                                <listitem>
                                    <para xml:id="para_bfe0a800-9bd7-4ce9-9e92-b5872fbb19a3">Maintains client clock</para>
                                </listitem>
                            </varlistentry>
                            <varlistentry>
                                <term>SNTP Client</term>
                                <listitem>
                                    <para xml:id="para_c96bb8db-0bc1-4009-8c1c-633959ecd56b">Maintains client clock</para>
                                </listitem>
                            </varlistentry>
                            <varlistentry>
                                <term>NTP Servers</term>
                                <listitem>
                                    <para xml:id="para_4952a965-dc9f-4479-9625-397d51e693f6">External time servers. These may have connections to other time servers, and may be synchronized with national time sources.</para>
                                </listitem>
                            </varlistentry>
                        </variablelist>
                    </section>
                    <section label="G.1.1.3" status="4" xml:id="sect_G.1.1.3">
                        <title>Referenced Standards</title>
                        <para xml:id="para_372e551e-8da1-4d2b-b42f-6baffb829f8a">
                            <xref linkend="biblio_RFC_2030"/> Simple Network Time Protocol (SNTP) Version 4</para>
                        <para xml:id="para_aa1a8df0-22e8-4b64-a236-b999d74a57ed">
                            <xref linkend="biblio_RFC_5905"/> Network Time Protocol Version 4: Protocol and Algorithms Specification</para>
                        <para xml:id="para_248bc6ac-2a1d-4e16-874f-b57f534650b6">
                            <xref linkend="biblio_RFC_5906"/> Network Time Protocol Version 4: Autokey Specification</para>
                        <para xml:id="para_87decc42-e898-478b-a6fb-320aa71c9a10">
                            <xref linkend="biblio_RFC_8633"/> Network Time Protocol Best Current Practices</para>
                    </section>
                    <section label="G.1.1.4" status="4" xml:id="sect_G.1.1.4">
                        <title>Basic Course of Events.</title>
                        <para xml:id="para_03d27d8a-246d-477f-b694-bc64144615b0">The NTP Client uses a list of NTP Servers, which may be:</para>
                        <itemizedlist>
                            <listitem>
                                <para xml:id="para_59815bdf-1e18-4c4a-8623-7e3c60712b46">obtained through optional NTP discovery mechanisms (see <xref linkend="biblio_RFC_5905"/>Section 3.1),</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_94e09f83-8455-4487-b384-8ffd4aef82f5">provided by a DHCP Server, see Annex F on DHCP, and/or</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_a11c4e24-5eca-4099-af8a-2b9ecfc80619">manually configured.</para>
                            </listitem>
                        </itemizedlist>
                        <para xml:id="para_3b6f5224-fa97-40c3-a97b-312983b00956">If the list is not empty, the client shall attempt to maintain time synchronization with at least one of the NTP servers.
                            The client synchronization shall be in compliance with either <xref linkend="biblio_RFC_5905"/> (NTP) or <xref linkend="biblio_RFC_2030"/> (SNTP).
                            If the list is empty, the client may choose an alternative method of time synchronization.</para>
                        <para xml:id="para_951a0deb-40b1-47a3-8792-7510dccca8fd">SNTP provides much lower accuracy than NTP.
                            If time synchronization of better than 1s mean error is required, the client should use NTP.
                            <xref linkend="biblio_RFC_5905"/> and <xref linkend="biblio_RFC_8633"/> discuss implementation and accuracy considerations.</para>
                        <para xml:id="para_fab75851-df8a-4c2d-a25a-9ca747d8ddc8">A DHCP server may provide to the DHCP Client a UTC offset between the local time at the machine and UTC, which the client shall use for converting between UTC and local time.</para>
                    </section>
                    <section label="G.1.1.5" status="4" xml:id="sect_G.1.1.5">
                        <title>Alternative Paths</title>
                        <para xml:id="para_335ace0c-a43c-43cf-8855-087ade3d8e16">If there is no UTC offset information from the DHCP or NTP server, then the UTC offset will be obtained in a device specific manner (e.g., service, CMOS, internal battery clock).</para>
                    </section>
                    <section label="G.1.1.6" status="4" xml:id="sect_G.1.1.6">
                        <title>Assumptions</title>
                        <para xml:id="para_e1b0cce7-d59a-4dc3-8908-9c126870fba3">The local battery clock time is set to UTC, or the local operating system has proper support to manage both battery clock time, NTP clock time, and system clock time. The NTP time is always in UTC.</para>
                    </section>
                    <section label="G.1.1.7" status="4" xml:id="sect_G.1.1.7">
                        <title>Postconditions</title>
                        <para xml:id="para_4f61a9de-75e6-4540-b36d-7556b29605cd">The client will remain synchronized with its selected time source. In an environment with one or more NTP servers, this will be good time synchronization. In the absence of NTP servers, the selected source will be the internal client clock.</para>
                    </section>
                </section>
                <section label="G.1.2" status="3" xml:id="sect_G.1.2">
                    <title>Maintain Time</title>
                    
                    <section label="G.1.2.1" status="4" xml:id="sect_G.1.2.1">
                        <title>Scope</title>
                        
                        <para xml:id="para_13dba35c-a573-4aeb-a40e-e4e08336ca09">This applies to any client that needs the correct time, or that needs to have its time stamps synchronized with those of another system. The accuracy of synchronization is determined by details of the configuration and implementation of the network and NTP servers at any specific site.</para>
                    </section>
                    <section label="G.1.2.2" status="4" xml:id="sect_G.1.2.2">
                        <title>Use Case Roles</title>
                        
                        <para xml:id="para_33490feb-1650-4cee-a6db-85725fcf058c">
                            <figure label="G.2-1" pgwide="1" xml:id="figure_G.2-1">
                                <title>Maintain Time</title>
                                <mediaobject>
                                    <imageobject>
                                        <imagedata fileref="figures/PS3.15_G.2-1.svg"/>
                                        <!--<imagedata fileref="part15_fromword_files/image020.png"/>-->
                                    </imageobject>
                                </mediaobject>
                            </figure>
                        </para>
                        <variablelist>
                            <varlistentry>
                                <term>NTP/SNTP Client</term>
                                <listitem>
                                    <para xml:id="para_e44ad7e2-df93-4b36-ab30-bb665c4f9ca6">Maintains client clock</para>
                                </listitem>
                            </varlistentry>
                            <varlistentry>
                                <term>NTP Servers</term>
                                <listitem>
                                    <para xml:id="para_219f0aca-93de-4a24-a21e-1f775d99130d">External time servers. These may have connections to other time servers, and may be synchronized with national time sources.</para>
                                </listitem>
                            </varlistentry>
                        </variablelist>
                    </section>
                    <section label="G.1.2.3" status="4" xml:id="sect_G.1.2.3">
                        <title>Referenced Standards</title>
                        <para xml:id="para_e5646722-26ef-46b7-8d77-b7c0fff25aa2">
                            <xref linkend="biblio_RFC_2030"/> Simple Network Time Protocol (SNTP) Version 4</para>
                        <para xml:id="para_ab5975a4-e0fc-4780-aa08-393ab7a81df9">
                            <xref linkend="biblio_RFC_2827"/> Network Ingress Filtering: Defeating Denial of Service Attacks which employ IP Source Address Spoofing</para>
                        <para xml:id="para_3cedce94-3713-4ac5-a03a-aac08697a067">
                            <xref linkend="biblio_RFC_5905"/> Network Time Protocol Version 4: Protocol and Algorithms Specification</para>
                        <para xml:id="para_bdaf7172-4b2b-4a08-9e0e-9b960913f305">
                            <xref linkend="biblio_RFC_5906"/> Network Time Protocol Version 4: Autokey Specification</para>
                        <para xml:id="para_41bce424-1e50-449b-a22c-409a56ad19c9">
                            <xref linkend="biblio_RFC_8633"/> Network Time Protocol Best Current Practices</para>
                    </section>
                    <section label="G.1.2.4" status="4" xml:id="sect_G.1.2.4">
                        <title>Basic Course of Events.</title>
                        <para xml:id="para_a4409ba6-9707-4fb3-b790-0dda3f158551">The detail on Maintain Time transactions is described in <xref linkend="biblio_RFC_5905"/> and <xref linkend="biblio_RFC_2030"/>.
                            The most common and the mandatory minimum mode for NTP operation uses a series of messages between client and servers.
                            The client sends requests to the servers, which fill in time related fields in a response, and the client performs optimal estimation of the present time based on that information.
                            The RFCs deal with issues of lost messages, estimation formulae, etc.
                            Once the clocks are in synchronization these message exchanges typically stabilize at roughly 1000 second intervals.</para>
                        <para xml:id="para_483906c6-fd0d-4bfc-8d5c-bbb986cf8163">The client machine uses the time estimate to maintain the internal operating system clock. This clock is then used by applications that need time information. This approach eliminates the application visible difference between synchronized and unsynchronized time. The RFCs provide guidance on proper implementations.</para>
                    </section>
                </section>
                <section label="G.1.3" status="3" xml:id="sect_G.1.3">
                    <title>NTP Security Considerations (Informative)</title>
                    <para xml:id="para_b953f9d7-3d38-4fb2-8bd2-c04c9d7f2b63">NTP security considerations (<xref linkend="biblio_RFC_5905"/> Section 8, <xref linkend="biblio_RFC_5906"/>, and <xref linkend="biblio_RFC_8633"/>) may be applicable based on site-specific environment and threat considerations.
                        Locations with NTP Servers should also consider <xref linkend="biblio_RFC_2827"/> and implementing access controls on the use of the server.</para>
                    <para xml:id="para_d4acc6ed-b598-4367-9341-5480bc55889b">Security Policies and Procedures for NTP are maintained at <link xl:href="http://www.nwtime.org/security-policy/"/> as part of the Network Time Foundation.</para>
                </section>
                <section label="G.1.4" status="3" xml:id="sect_G.1.4">
                    <title>NTP Implementation Considerations (Informative)</title>
                    <para xml:id="para_72aa46a6-0514-45b6-8ceb-2bdb644b4b9d">NTP compliant servers always support both NTP and SNTP clients.
                        The difference is one of synchronization accuracy, not communications compatibility.
                        Although in theory both NTP and SNTP clients could run at the same time on the same system, this is not recommended.
                        The SNTP updates will simply degrade the time accuracy.
                        When other time protocol clients, such as IRIG, are also being used, these clients must be coordinated with the NTP client to avoid synchronization problems.</para>
                    <para xml:id="para_680f2382-0521-437b-a53a-f81a30806f43">These and other considerations, such as multiple clock types, accuracy implications, and configuration alternatives, are documented at <link xl:href="http://www.ntp.org"/>.</para>
                </section>
                <section label="G.1.5" status="3" xml:id="sect_G.1.5">
                    <title>Conformance</title>
                    <para xml:id="para_48aae726-a244-4a3b-82b5-f522d8a1aeab">The Conformance Statement for the NTP Server and NTP Client shall state whether secure transactions (<xref linkend="biblio_RFC_5906"/>) are supported.</para>
                    <para xml:id="para_d082e2cb-f95b-4744-bfea-12c4d72510a7">The Conformance Statement for the NTP Server shall state whether it is also an NTP Client.</para>
                    <para xml:id="para_2ad23b6e-ddbf-42d3-a083-6eee630b2803">The Conformance Statement for the NTP Client shall state how it manages time when no NTP Server is available.</para>
                </section>
            </section>
        </chapter>
    
<chapter label="H" status="1" xml:id="chapter_H">
    <title>Application Configuration Management Profiles</title>
  
  <section label="H.1" status="2" xml:id="sect_H.1">
    <title>Application Configuration Management Profile</title>
  
  <para xml:id="para_8f3755de-1dbd-48de-b0a0-8ffbb7490745">The Application Configuration Management Profile applies to the actors LDAP Server, LDAP Client, and DNS Server. The mandatory and optional transactions are described in the table and sections below.</para>
    <table frame="box" label="H.1-1" rules="all" xml:id="table_H.1-1">
    <caption>Application Configuration Management Profiles</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_70c57551-aa7d-4157-925f-c237e9e7e779">Actor</para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_7ee878d6-5e6d-40b5-a0a6-42bc17c80b34">Transaction</para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_c60ce169-3449-4970-8ec1-1fe40a2df6af">Optionality</para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_0da4d063-22d4-46a7-bada-79f60d53506d">Section</para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e61ae857-c7c3-4963-9399-ed93d1d3b7f2">LDAP Server</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_7fb4506d-a7e2-4aa4-a2e7-dba79ddbdada">Query LDAP Server</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f56df052-e904-4cdf-844a-374d2fd041a3">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6fb87aea-0edd-4090-812d-cb17df1e7426">H.1.4.2</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1"/>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5b809f9d-1437-48f0-956a-374815e8810b">Update LDAP Server</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_32bd4e41-ebb4-4767-9071-da216be18d53">O</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_006730af-91a3-4274-87b8-0c632bff26e3">H.1.4.3</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1"/>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0b0fdea5-57ca-41bc-bf70-96e145e5c249">Maintain LDAP Server</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_fdc59e44-d8ca-4234-b2e5-8a590be4aeb8">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1f358d66-e923-4c53-bef1-68637b71bcc5">H.1.4.4</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_570126a7-6e3a-426e-ad77-8ef166526694">LDAP Client</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_17f82c52-a8bd-4e35-a6d3-3d02ff14b649">Find LDAP Server</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_aefe4405-21f4-43fe-9f7f-6edf24a8b33c">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_40b70fb5-5d80-47f1-8552-84ac0415398d">H.1.4.1</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1"/>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_86a78c48-8e8f-48a7-9629-594e8e48077e">Query LDAP Server</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_cc1b54c1-875c-40d8-92d3-dceb8de1ca5c">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_13cbfe8d-61a8-434f-87cb-362f3a7e238d">H.1.4.2</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1"/>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_bfb41193-5c59-4517-b9a4-ff609e549642">Update LDAP Server</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7e0e3464-8cf2-479d-9d29-21ef144afccc">O</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d93e4fa5-135c-4bd9-a8b2-0b3f5f264372">H.1.4.3</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b720685d-8407-48c5-8a9c-25488fe8b4a0">DNS Server</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f64b6ba6-5b70-4152-a582-aea5f6046e08">Find LDAP Server</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_dc36a872-10cc-4493-9284-00242a092195">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_538487b6-a3ac-42e2-a61f-57ce4c01cd9d">H.1.4.1</para>
      </td>
    </tr>
  </tbody>
  </table>
      <section label="H.1.1" status="3" xml:id="sect_H.1.1">
        <title>Data Model Component Objects</title>
        <para xml:id="para_dd0dd583-a450-4b1e-82e0-7c0faf1125c2">The normative definition of the schema can be found in <xref linkend="sect_H.1.3" xrefstyle="select: label"/>. This section gives additional informative descriptions of the objects and information defined in that schema and makes normative statements regarding DICOM system behavior.</para>
        <para xml:id="para_3aa716dd-97df-4ecf-9369-1948a07933bb">The Application Configuration Data Model has the following component objects:</para>
        <variablelist>
          <varlistentry>
            <term>Device</term>
            <listitem>
              <para xml:id="para_5738f59e-6889-4e0b-a3d2-289a86225262">The description of the device</para>
            </listitem>
          </varlistentry>
          <varlistentry>
            <term>Network AE</term>
            <listitem>
              <para xml:id="para_eee0be0e-6370-4a64-9a50-e695a21f44eb">The description of the network application entity</para>
            </listitem>
          </varlistentry>
          <varlistentry>
            <term>Network Connection</term>
            <listitem>
              <para xml:id="para_6e07ad4f-c93a-4648-b417-15d2aec9051e">The description of the network interface</para>
            </listitem>
          </varlistentry>
          <varlistentry>
            <term>Transfer Capability</term>
            <listitem>
              <para xml:id="para_0ea49187-c8f9-491b-8ff2-6fcaa07458fd">The description of the SOP classes and syntaxes supported by a Network AE.</para>
            </listitem>
          </varlistentry>
        </variablelist>
        <para xml:id="para_accc596d-3ee0-4516-818e-22e2f9dda4fa">
          <figure label="H.1-1" pgwide="1" xml:id="figure_H.1-1">
            <title>Application Configuration Data Model</title>
            <mediaobject>
              <imageobject>
                <imagedata fileref="figures/PS3.15_H.1-1.svg"/>
                <!--<imagedata fileref="part15_fromword_files/image022.png"/>-->
              </imageobject>
            </mediaobject>
          </figure>
        </para>
        <para xml:id="para_666ac4bf-5f5c-4569-86a5-1e54b9452a62">In addition there are a number of other objects used in the LDAP schema (see <xref linkend="sect_H.1.2" xrefstyle="select: label"/> and <xref linkend="figure_H.1-2" xrefstyle="select: label"/>) :</para>
        <variablelist>
          <varlistentry>
            <term>DICOM Configuration Root</term>
            <listitem>
              <para xml:id="para_4c4674ed-b56f-4e9f-8f67-1ea723b67519">The root of DICOM Configuration Hierarchy</para>
            </listitem>
          </varlistentry>
          <varlistentry>
            <term>DICOM Devices Root</term>
            <listitem>
              <para xml:id="para_17ee104b-5150-4b22-a1b4-b3a0a37da3ed">The root of the DICOM Devices Hierarchy</para>
            </listitem>
          </varlistentry>
          <varlistentry>
            <term>DICOM Unique AE-Title Registry Root</term>
            <listitem>
              <para xml:id="para_760b9932-affe-4931-86c4-a538e9a7e529">The root of the Unique DICOM AE-Title Registry</para>
            </listitem>
          </varlistentry>
          <varlistentry>
            <term>DICOM Unique AE Title</term>
            <listitem>
              <para xml:id="para_212ee0ae-9f2c-4ec8-89e7-37b62858a1fe">A unique AE Title within the AE Title Registry</para>
            </listitem>
          </varlistentry>
        </variablelist>
        <para xml:id="para_86986a82-0ce0-4369-9cc3-e9e3820f97f0">LDAP permits extensions to schema to support local needs (i.e., an object may implement a single structural and multiple auxiliary LDAP classes). DICOM does not mandate client support for such extensions. Servers may support such extensions for local purposes. DICOM Clients may accept or ignore extensions and shall not consider their presence an error.</para>
        <section label="H.1.1.1" status="4" xml:id="sect_H.1.1.1">
          <title>Device</title>

          <para xml:id="para_2b919f9b-dcac-4d89-bab5-29daf7900644">The "device" is set of components organized to perform a task rather than a specific physical instance. For simple devices there may be one physical device corresponding to the Data Model device. But for complex equipment there may be many physical parts to one "device".</para>
          <para xml:id="para_fc77cec7-e069-463d-ab58-de09c61a4b33">The "device" is the collection of physical entities that supports a collection of Application Entities. It is uniquely associated with these entities and vice versa. It is also uniquely associated with the network connections and vice versa. In a simple workstation with one CPU, power connection, and network connection the "device" is the workstation.</para>
          <para xml:id="para_9b186490-30fe-49e0-9033-603e1518eaeb">An example of a complex device is a server built from a network of multiple computers that have multiple network connections and independent power connections. This would be one device with one application entity and multiple network connections. Servers like this are designed so that individual component computers can be replaced without disturbing operations. The Application Configuration Data Model does not describe any of this internal structure. It describes the network connections and the network visible Application Entities. These complex devices are usually designed for very high availability, but in the unusual event of a system shutdown the "device" corresponds to all the parts that get shut down.</para>
          <table frame="box" label="H.1-2" rules="all" xml:id="table_H.1-2">
            <caption>Attributes of Device Object</caption>
            <thead>
              <tr valign="top">
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_66876e12-4bcb-4e3a-889a-d9e76a1807e3">Information Field</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_5078d807-be9d-45c0-be0d-3329b731dcec">Multiplicity</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_8cc89263-2649-42dd-a545-83846a7b9c32">Description</para>
                </th>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_ab34af22-6668-4920-8a36-7197b43190b1">Device Name</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_9f6463e6-0f11-4764-a7ba-04426baa9b17">1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_4211ae65-81d0-493d-98b4-fcecb4c98fcf">A unique name (within the scope of the LDAP database) for this device. It is restricted to legal LDAP names, and not constrained by DICOM AE Title limitations.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_32c4af66-2b4b-4b3f-ad99-22c132ce650d">Description</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_f6ceca81-3ae5-467d-89f9-165e2a97185b">0..1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_2e3df658-c9a5-4e1d-886b-992c227e077d">Unconstrained text description of the device.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_e2cdb745-9c62-4fe9-8aec-290df0c37591">Manufacturer</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_1c361b85-d0ea-4230-8b88-f3bb3eabcd69">0..1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_36601945-b059-478b-98ea-1fea5c426ffb">Should be the same as the Value of Manufacturer (0008,0070) in SOP instances created by this device.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_846d723e-9312-4422-9a26-a69c71e954ee">Manufacturer Model Name</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_4b9c75e9-d17b-411a-be1a-ef4e7e98fb60">0..1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_4f3bb153-ce54-4c44-85ad-94f87a0c2e04">Should be the same as the Value of Manufacturer Model Name (0008,1090) in SOP instances created by this device.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_65344439-2baf-4fa9-a5be-e68e5742c05b">Software Version</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_e3a937c3-bffe-4e2c-a6b7-5fa504d33c00">0..N</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_2e58e00b-72e1-4651-ad60-69b0ba44a64f">Should be the same as the Values of Software Versions (0018,1020) in SOP instances created by this device.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_5c9a890d-3136-4cff-9123-761df059fe89">Station Name</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_77d7f945-8ac9-4835-b2ea-408b36e5fb89">0..1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_2dc8d8bb-a6a8-49f6-a6e2-26b4e63c6a5a">Should be the same as the Value of Station Name (0008,1010) in SOP instances created by this device.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_57da2665-ad95-421a-95f7-d144a5865538">Device Serial Number</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_f99a4953-dbee-4a5d-ad5e-da5080fc4bef">0..1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_3379fc4c-b726-48d1-ae81-ee41fe45a47c">Should be the same as the Value of Device Serial Number (0018,1000) in SOP instances created by this device.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_e222fae0-0d12-4f32-8ac9-8d6af69cd63d">Primary Device Type</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_9d96c7c6-8553-42df-80ec-1324d4b21373">0..N</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_79ac6be7-e6d5-4779-8956-98a81036c3df">Represents the kind of device and is most applicable for acquisition modalities. Types should be selected from the list of codes for Code Value (0008,0100) for <olink targetdoc="PS3.16" targetptr="sect_CID_30" xrefstyle="select: labelnumber quotedtitle"/> when applicable.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_419528d1-2f31-489c-be2c-56f084443182">Institution Name</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_7f291a47-714d-4bff-b0f7-2f5a5ef8e921">0..N</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_0423e838-dd4e-40e6-992d-6914c8c540b8">Should be the same as the Value of Institution Name (0008,0080) in SOP Instances created by this device.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_e4350538-2f1e-4a66-9744-3bf5be79a7e6">Institution Address</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_47a2a108-22ea-4ea4-89ac-7747c9af8e41">0..N</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_03edc028-35f4-4cdb-8369-406dad324564">Should be the same as the Value of Institution Address (0008,0081) attribute in SOP Instances created by this device.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_9dd3f61d-8b30-4ea9-b8ff-d8610321e088">Institutional Department Name</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_56822193-2bef-4b25-9c8f-ec31e96b4ce1">0..N</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_96e3d265-e67a-4288-88f9-f447c757c640">Should be the same as the Value of Institutional Department Name (0008,1040) in SOP Instances created by this device.</para>
                </td>
              </tr>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_eddb9182-500e-41b9-800e-79cebc6e1f7f">Institutional Department Type Code Sequence</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_9f1bfc5e-a599-4e93-82ea-101292c0a384">0..N</para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_057d9083-c083-4f15-8fc4-2aa4b8ec0f2f">Should be the same as the Value of Institutional Department Type Code Sequence (0008,1041) in SOP Instances created by this device.</para>
                    </td>
                </tr>
                <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_f5f55274-51d0-408b-b6e6-f12bac3cf0f6">Issuer of Patient ID</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_fcd6a1e2-c1e4-4e1f-b47f-31bda2ede847">0..1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_81042308-43ef-47f6-b374-274521ce2f25">Default Value for the Issuer of Patient ID (0010,0021) for SOP Instances created by this device. May be overridden by the values received in a worklist or other source.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_c3f032df-06a9-429c-a078-0daef1839432">Related Device Reference</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_c29dba06-1c89-414d-adb3-e08adf0952a2">0..N</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_49f23819-c476-49b3-9622-675e1c2ddbab">The DNs of related device descriptions outside the DICOM Configuration hierarchy. Can be used to link the DICOM Device object to additional LDAP objects instantiated from other schema and used for separate administrative purposes.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_05c6b4cd-45c9-4ef2-a150-577e68b5b081">Authorized Node Certificate Reference</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_90d528b2-b975-441a-872e-ed64acf25c9f">0..N</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_d78160dc-b7ee-45a2-8466-0a56866d1b1a">The DNs for the certificates of nodes that are authorized to connect to this device. The DNs need not be within the DICOM configuration hierarchy.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_438b7f2f-d289-4c9d-9315-887ed76999fa">This Node Certificate Reference</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_1d3dfd1b-505b-465b-b322-bbc76f0ecefa">0..N</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_133c322a-fe35-4b14-ae33-3053efe7b01e">The DNs of the public certificate(s) for this node. The DNs need not be within the DICOM configuration hierarchy.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_8e778be3-0f09-40fe-83ed-05a3d02acb0e">Vendor Device Data</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_9ee420ba-9577-4b58-9a86-b877c4210634">0..N</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_fc42d3aa-e0fc-45c5-bef3-58f5b1b82bf7">Device specific vendor configuration information</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_60d9c26d-9b51-47e9-86e7-c3fb89ecec66">Installed</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_120c984a-89b2-4aa1-8d45-5642c3aa3f66">1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_bb4956d1-46b8-494d-acc4-b5695b326ff3">Boolean to indicate whether this device is presently installed on the network. (This is useful for pre-configuration, mobile vans, and similar situations.)</para>
                </td>
              </tr>
            </tbody>
          </table>
          <para xml:id="para_c4fb88b6-73ce-4679-b4a5-d51aa97aa53a">The "Authorized Node Certificate Reference" is intended to allow the LDAP server to provide the list of certificates for nodes that are authorized to communicate with this device. These should be the public certificates only. This list need not be complete. Other network peers may be authorized by other mechanisms.</para>
          <para xml:id="para_59d92cff-f7f5-4b21-8ce7-127e3b2b558e">The "This Node Certificate Reference" is intended to allow the LDAP server to provide the certificate(s) for this node. These may also be handled independently of LDAP.</para>
          <note>
            <para xml:id="para_9f97ed2f-51a0-4574-acfc-dfd696b88d4f">A device may have multiple Primary Device Type entries. It may be a multifunctional device, e.g., combined PET and CT. It may be a cascaded device, e.g., image capture and ultrasound.</para>
          </note>
          <table frame="box" label="H.1-3" rules="all" xml:id="table_H.1-3">
            <caption>Child Objects of Device Object</caption>
            <thead>
              <tr valign="top">
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_96f8ddc6-33e2-4133-b90b-9a131e86ba23">Information Field</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_f31523f3-bcc2-45e4-95b9-789c13e6adb6">Multiplicity</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_66ec93f6-5a07-4832-b4b8-0ee965240bde">Description</para>
                </th>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_96e18e9c-6c1f-4819-93a0-e10a015ae95a">Network Application Entity</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_70e29d81-1d5e-4e53-9958-e78f6ac3f31b">1..N</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_e6c3b254-43de-4a35-a145-1c2d65e2f411">The application entities available on this device (see <xref linkend="sect_H.1.1.2" xrefstyle="select: label"/>)</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_d3b8d4ae-9a2c-46b7-a0d8-53d9adce6d22">Network Connection</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_77bb69a5-62cb-4529-b578-941952ff3432">1..N</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_c441a044-de88-4987-9ac1-0f173094e04d">The network connections for this device (see <xref linkend="sect_H.1.1.3" xrefstyle="select: label"/>)</para>
                </td>
              </tr>
            </tbody>
          </table>
        </section>
        <section label="H.1.1.2" status="4" xml:id="sect_H.1.1.2">
          <title>Network Application Entity</title>

          <para xml:id="para_032dc9f6-6785-4844-aa4c-d819dd956b42">A Network AE is an application entity that provides services on a network. A Network AE will have the same functional capability regardless of the particular network connection used. If there are functional differences based on selected network connection, then these are separate Network AEs. If there are functional differences based on other internal structures, then these are separate Network AEs.</para>
          <table frame="box" label="H.1-4" rules="all" xml:id="table_H.1-4">
            <caption>Attributes of Network AE Object</caption>
            <thead>
              <tr valign="top">
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_d79db747-f878-4afa-aa94-89efa5e4b73d">Information Field</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_29e62967-0cf0-4c4b-8087-51cdd0dc1809">Multiplicity</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_3684ad7f-6cc4-4af0-ad9d-3dede9383aaa">Description</para>
                </th>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_75c34f4a-b53c-402a-8bb7-662831441527">AE Title</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_32debed6-c941-4232-947d-9220aabc525e">1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_c74f4009-5d17-4a7b-b376-8844b5f2bee0">Unique AE title for this Network AE</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_381cc58b-0e60-490c-af1d-6210275de4ee">Description</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_e5837f59-f7aa-496e-b4d4-6051a75f2330">0..1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_67641d25-8ced-490d-855a-06a45bb69892">Unconstrained text description of the application entity.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_916ef157-2887-41b3-90ed-7d1e0e521281">Vendor Data</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_8f97f423-342e-4994-b95d-eee70a9cd3ee">0..N</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_bfe68335-1b5d-458f-a554-3bfb1637e2ae">AE specific vendor configuration information</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_5f1a7474-88bf-49ee-a2bd-e34dbf97ec5e">Application Cluster</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_13446c42-c54f-401f-a29e-735dbe21e576">0..N</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_87ab27c5-c765-4cda-a6da-943ec828d628">Locally defined names for a subset of related applications. E.g. "neuroradiology".</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_27b6c32c-d970-4be1-b5fc-4e20fc0509b5">Preferred Called AE Title</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_1397d8bf-2f9a-49da-924d-82e49810734d">0..N</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_202fd525-b371-47cc-a3a6-7603e2fc50d8">AE Title(s) that are preferred for initiating associations.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_e010d20c-f22f-4edb-8bbf-5a6af9aed763">Preferred Calling AE Title</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_9e1b905f-60cb-4be7-9ef4-c95c0ab69ba8">0..N</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_c47791f9-6d8f-4503-ba63-7576f48eac01">AE Title(s) that are preferred for accepting associations.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_0deaa0bf-fbd0-44f2-9a5a-71b199cf93a1">Association Acceptor</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_535772fa-25b7-416a-a316-379e158e0be1">1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_9ea61bf5-3a45-4d9d-ba51-9a6215a32850">A Boolean value. True if the Network AE can accept associations, false otherwise.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_73078bb9-6a2d-4036-8a37-ec363f1195ab">Association Initiator</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_d985020a-17ad-4541-adba-47be0911f6c3">1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_01c2893a-0017-4a62-a063-2a4d32507db4">A Boolean value. True if the Network AE can accept associations, false otherwise.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_1d0cf42f-1012-47dc-b9ff-939514a2bf71">Network Connection Reference</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_3a6e93a7-fc91-4d17-93e7-df814628e9aa">1..N</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_6691fd00-0bb5-48c0-8a54-df752cf9f5c4">The DNs of the Network Connection objects for this AE</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_24fcd8d9-bb00-4334-aa67-dff877074186">Supported Character Set</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_c36fabde-5528-4ab4-8bed-c405ce6c9b5a">0..N</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_10c6fa0e-d306-44d8-92c1-aeee9d30cba7">The Character Set(s) supported by the Network AE for Data Sets it receives. The value shall be selected from the Defined Terms for Specific Character Set (0008,0005) in <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>. If no values are present, this implies that the Network AE supports only the default character repertoire (ISO IR 6).</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_93138650-7e9a-4cee-af01-92fbf8b127c4">Installed</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_609aec0e-7c9b-4285-b74f-dcfaea7e9278">0..1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_d6906c8f-5d49-4d24-b868-c72f516da4d0">A Boolean value. True if the AE is installed on network. If not present, information about the installed status of the AE is inherited from the device</para>
                </td>
              </tr>
            </tbody>
          </table>
          <para xml:id="para_b2098324-c30f-45a8-ab87-aec09bd6ff79">The "Application Cluster" concept provides the mechanism to define local clusters of systems. The use cases for Configuration Management require a "domain" capability for DICOM applications that would be independent of the network topology and administrative domains that are used by DNS and other TCP level protocols. The Application Cluster is multi-valued to permit multiple clustering concepts for different purposes. It is expected to be used as part of a query to limit the scope of the query.</para>
          <para xml:id="para_b69675a4-770d-48d1-ac0e-08016bfc8d84">The "Preferred Called AE Title" concept is intended to allow a site administrator to define a limited default set of AEs that are preferred for use as communication partners when initiating associations. This capability is particularly useful for large centrally administered sites to simplify the configuration possibilities and restrict the number of configured AEs for specific workflow scenarios. For example, the set of AEs might contain the AE Titles of assigned Printer, Archive, RIS and QA Workstations so that the client device could adapt its configuration preferences accordingly. The "Preferred Called AE Title" concept does not prohibit association initiation to unlisted AEs. Associations to unlisted AEs can be initiated if necessary.</para>
          <para xml:id="para_7008e72c-1af0-421c-893c-bc18e9a11dd3">The "Preferred Calling AE Title" concept is intended to allow a site administrator to define a default set of AEs that are preferred when accepting assocations. The "Preferred Calling AE Title" concept does not prohibit accepting associations from unlisted AEs.</para>
          <para xml:id="para_3ce27882-44c6-418c-8a37-1a854aac2154">The "Network Connection Reference" is a link to a separate Network Connection object. The referenced Network Connection object is a sibling the AE object (i.e., both are children of the same Device object).</para>
          <table frame="box" label="H.1-5" rules="all" xml:id="table_H.1-5">
            <caption>Child Objects of Network AE Object</caption>
            <thead>
              <tr valign="top">
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_a4867a30-b2b0-480a-b71e-debd11df1a78">Information Field</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_434b5a85-9953-4af3-9f3b-10525b25ef3d">Multiplicity</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_037bd1cd-2bc4-47cb-8598-855f6bb511d0">Description</para>
                </th>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_a8144f9e-baf9-404b-8d6d-185d0b73233d">Transfer Capability</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_afc9395b-9856-4ba9-8842-d5e30086b654">1..N</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_49b2263d-93e7-49a3-a642-7602da361fbd">The Transfer Capabilities for this Network AE. See <xref linkend="sect_H.1.4" xrefstyle="select: label"/>
                  </para>
                </td>
              </tr>
            </tbody>
          </table>
        </section>
        <section label="H.1.1.3" status="4" xml:id="sect_H.1.1.3">
          <title>Network Connection</title>

          <para xml:id="para_19adbcd8-3ae6-40da-b8b8-402552ad1aa0">The "network connection" describes one TCP port on one network device. This can be used for a TCP connection over which a DICOM association can be negotiated with one or more Network AEs. It specifies the hostname and TCP port number. A network connection may support multiple Network AEs. The Network AE selection takes place during association negotiation based on the called and calling AE-titles.</para>
          <table frame="box" label="H.1-6" rules="all" xml:id="table_H.1-6">
            <caption>Attributes of Network Connection Object</caption>
            <thead>
              <tr valign="top">
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_ff68eed9-a2a4-4f06-95fa-87be52eac29a">Information Field</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_9841149f-cbc4-48ae-8718-27ce6916fa87">Multiplicity</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_a4be364d-af0b-46c7-aed6-ef0b8e6d66f2">Description</para>
                </th>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_8920cb0c-ee49-43d0-91f3-2c95928a6096">Common Name</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_6194be9c-53b1-42c9-adb6-4147baf3f1a4">0..1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_0012c0f8-e158-4d86-a0d4-01fe1577d276">An arbitrary name for the Network Connections object. Can be a meaningful name or any unique sequence of characters. Can be used as the RDN.</para>
                  <note>
                    <para xml:id="para_feb0a802-89b6-44a9-9930-1feb3f3e27b8">The "cn" attribute type is a basic LDAP defined type and is a synonym for Common Name.</para>
                  </note>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_29061735-61bd-4463-ac71-2badc82138ce">Hostname</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_0faf275c-4e63-4d64-9dc4-f92990a014cb">1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_d800d1bf-7680-48ae-9aa0-1e0b08e83d1a">This is the DNS name for this particular connection. This is used to obtain the current IP address for connections. Hostname must be sufficiently qualified to be unambiguous for any client DNS user.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_d79564ec-d82e-409d-9f82-96a59a42fd40">Port</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_757ad479-c0bc-4105-a74f-552cb190c198">0..1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_19ff7944-4726-4dd6-af6e-2f02b02d5a36">The TCP port that the AE is listening on. (This may be missing for a network connection that only initiates associations.)</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_dd74452c-789e-4c11-b97a-20a802eadd02">TLS CipherSuite</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_6ec005cd-d61a-41df-ab63-9541120e0103">0..N</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_1de9c436-4d82-460c-851a-6fc443420032">The TLS CipherSuites that are supported on this particular connection. TLS CipherSuites shall be described using an <xref linkend="biblio_RFC_2246"/> string representation (e.g., "TLS_RSA_WITH_RC4_128_SHA")</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_1479acaf-00bf-43b7-9b58-eb72823b32c4">Installed</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_7153e289-66f9-4a4e-a88f-449fdc3e0fb5">0..1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_0ac5562a-aeba-497b-ad75-87e7177a0b9b">A Boolean value. True if the Network Connection is installed on the network. If not present, information about the installed status of the Network Connection is inherited from the device.</para>
                </td>
              </tr>
            </tbody>
          </table>
          <para xml:id="para_4362234d-91ac-4810-832b-b48772638e2f">Inclusion of a TLS CipherSuite in a Network Connection capable of accepting associations implies that the TLS protocol must be used to successfully establish an association on the Network Connection.</para>
          <para xml:id="para_a585d181-6d7f-4c0a-9c67-6d829adf4557">A single Network AE may be available on multiple network connections. This is often done at servers for availability or performance reasons. For example, at a hospital where each floor is networked to a single hub per floor, the major servers may have direct connections to each of the hubs. This provides better performance and reliability. If the server does not change behavior based on the particular physical network connection, then it can be described as having Network AEs that are available on all of these multiple network connections. A Network AE may also be visible on multiple TCP ports on the same network hardware port, with each TCP port represented as a separate network connection. This would allow, e.g., a TLS-secured DICOM port and a classical un-secured DICOM port to be supported by the same AE.</para>
        </section>
        <section label="H.1.1.4" status="4" xml:id="sect_H.1.1.4">
          <title>Transfer Capabilities</title>

          <para xml:id="para_e36ae422-7084-4338-a9e2-67b4aebda522">Each Network AE object has one or more Transfer Capabilities. Each transfer capability specifies the SOP class that the Network AE can support, the mode that it can utilize (SCP or SCU), and the Transfer Syntax(es) that it can utilize. A Network AE that supports the same SOP class in both SCP and SCU modes will have two Transfer Capabilities objects for that SOP class.</para>
          <table frame="box" label="H.1-7" rules="all" xml:id="table_H.1-7">
            <caption>Attributes of Transfer Capability Object</caption>
            <thead>
              <tr valign="top">
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_d32d9534-cb78-4449-a20c-7910a0332711">Information Field</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_647919d0-20ad-433a-b110-4de54279cad3">Multiplicity</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_a320624f-ab8b-48af-a224-6eafab58839c">Description</para>
                </th>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_4cf5225c-3d3f-4db1-8202-aa9556952835">Common Name</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_f3f4522a-3045-4ca3-8f2f-050c385ad500">0..1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_5c0ff5bd-f666-4af4-a55f-69a1ec733c2e">An arbitrary name for the Transfer Capability object. Can be a meaningful name or any unqiue sequence of characters. Can be used as the RDN.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_7aae9bb3-bb98-4656-9e40-104b147064de">SOP Class</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_f260f23c-c301-4635-a4b1-77ab19e5652b">1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_1d1892b9-d09e-4336-a427-3c004f591c71">SOP Class UID</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_6ac7352a-fba6-4b37-88e6-61cd276b330c">Role</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_69ca0a70-3fbb-4e3b-bcc6-195cc6dd8d33">1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_188ae63a-9b9f-426d-863b-459d8cbc76a7">Either "SCU" or "SCP"</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_47562cfd-0342-490c-bde7-560a4a3d4ba3">Transfer Syntax</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_a4fc3694-ede9-401f-b5ed-6732a54d2805">1..N</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_ef9ac817-e102-41f1-8708-78d06fab155d">The transfer syntax(es) that may be requested as an SCU or that are offered as an SCP.</para>
                </td>
              </tr>
            </tbody>
          </table>
        </section>
        <section label="H.1.1.5" status="4" xml:id="sect_H.1.1.5">
          <title>DICOM Configuration Root</title>

          <para xml:id="para_99407ec8-07a8-4a08-adcf-e9b917021b0d">This structural object class represents the root of the DICOM Configuration Hierarchy. Only a single object of this type should exist within an organizational domain. Clients can search for an object of this class to locate the root of the DICOM Configuration Hierarchy.</para>
          <table frame="box" label="H.1-8" rules="all" xml:id="table_H.1-8">
            <caption>Attributes of the DICOM Configuration Root Object</caption>
            <thead>
              <tr valign="top">
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_dc14986d-eeda-45ed-a97b-726dffbd65e2">Information Field</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_76beb8c2-8909-423e-845b-8bfe8fc487f6">Multiplicity</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_45ef52f4-d185-4e9f-aad3-ff1fd318d6fc">Description</para>
                </th>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_13fbd3b7-44e1-497e-9cb1-770487a7c750">Common Name</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_ca982e59-b94d-46db-855e-94510367f4b2">1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_0e4c567b-6f58-4b59-8f5a-4abe6ca6dc7b">The Name for the Configuration Root. Should be used as the RDN. The name shall be "DICOM Configuration".</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_90e30ed4-2e3b-4630-9e91-7b86ee129e96">Description</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_e3c4fd46-b06a-4610-b437-7fa50d1def44">0..1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_4596152d-f59d-4188-bc05-816e081a56b7">Unconstrained text description.</para>
                </td>
              </tr>
            </tbody>
          </table>
          <table frame="box" label="H.1-9" rules="all" xml:id="table_H.1-9">
            <caption>Child Objects of DICOM Configuration Root Object</caption>
            <thead>
              <tr valign="top">
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_b0fed0db-c0af-41b3-82db-188526e48ef6">Information Field</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_79088e5d-ed27-44c6-b859-218697f2710e">Multiplicity</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_8a525c99-cdac-4a04-bb9e-b55a90300bfa">Description</para>
                </th>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_fff70ab0-2bd2-4be0-a4e8-239241cc2cc1">Devices Root</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_2d97fe96-3c39-4a24-87ba-b064d75ca850">1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_91adcf7a-2c66-45ea-920a-81948a3d5a2c">The root of the DICOM Devices Hierarchy</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_c01ffa01-cf80-4d5c-b449-ac440cff45ba">Unique AE Titles Registry Root</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_ea3570d0-f246-420d-a33b-896dee22a908">1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_420bd3fb-fe09-4c3c-bfee-008752605eeb">The root of the Unique AE Titles Registry</para>
                </td>
              </tr>
            </tbody>
          </table>
        </section>
        <section label="H.1.1.6" status="4" xml:id="sect_H.1.1.6">
          <title>Devices Root</title>

          <para xml:id="para_eddba9a0-7373-466a-adf7-37d6dee1e891">This structural object class represents the root of the DICOM Devices Hierarchy. Only a single object of this type should exist as a child of DICOM Configuration Root. Clients can search for an object of this class to locate the root of the DICOM Devices Hierarchy.</para>
          <table frame="box" label="H.1-10" rules="all" xml:id="table_H.1-10">
            <caption>Attributes of the Devices Root Object</caption>
            <thead>
              <tr valign="top">
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_d63cefcf-469a-4a34-a55b-3acc1275ee09">Information Field</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_f9afc451-dd5c-4b48-8623-1fadecec896f">Multiplicity</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_779ff568-a69f-4547-aed1-458eecec4d92">Description</para>
                </th>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_e82ef4d8-54d0-422d-9f8e-3e09b7ec27d3">Common Name</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_da7faaea-0f60-41b2-a3c2-c313d572623e">1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_c254d168-dc77-434c-8606-23421bff76fb">The Name for the Devices Root. Should be used as the RDN. The name shall be "Devices".</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_8ca7cdd8-c5a1-423c-a8f6-4c36f6639c08">Description</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_1340d616-4fae-41fb-826f-3481e098060e">0..1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_775a1264-fa0d-472a-8fad-5b3b6d8ba098">Unconstrained text description.</para>
                </td>
              </tr>
            </tbody>
          </table>
          <table frame="box" label="H.1-11" rules="all" xml:id="table_H.1-11">
            <caption>Child Objects of Devices Root Object</caption>
            <thead>
              <tr valign="top">
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_419e9704-35c0-4a66-9f98-1d95944f00f7">Information Field</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_7bc333f2-8554-4dbd-950f-dc8732b3d698">Multiplicity</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_032aeb28-d533-4357-9388-7c965fa5b81d">Description</para>
                </th>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_a82d3d5b-90ab-476f-98cb-0586dd10bfb3">Device</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_e3220240-af86-41ae-80b5-b4a5e2e65d06">0..N</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_f3a31668-6ef9-4cc1-bd4b-3d1e6a0757ae">The individual devices installed within this organizational domain.</para>
                </td>
              </tr>
            </tbody>
          </table>
        </section>
        <section label="H.1.1.7" status="4" xml:id="sect_H.1.1.7">
          <title>Unique AE Titles Registry Root</title>

          <para xml:id="para_19d25c42-b617-4984-bacc-cfc8d6cd0624">This structural object class represents the root of the Unique AE-Titles Registry Hierarchy. Only a single object of this type should exist as a child of the DICOM Configuration Root. Clients can search for an object of this class to locate the root of the Unique AE Titles Registry.</para>
          <table frame="box" label="H.1-12" rules="all" xml:id="table_H.1-12">
            <caption>Attributes of the Unique AE Titles Registry Root Object</caption>
            <thead>
              <tr valign="top">
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_731fa1eb-ee1e-40f8-976f-0043caf76ad8">Information Field</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_8f0d39bb-f3a3-487f-92e3-ef3406f39637">Multiplicity</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_147ea895-2d71-4a07-ace4-21e010aa9942">Description</para>
                </th>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_930397f0-91b6-4c10-88b6-1326023e6144">Common Name</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_5e00e7c4-f90e-411a-9ea0-3c396e91e5e9">1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_abd90b80-dbc6-4549-b592-b6eaa649ccf3">The Name for the Unique AE Titles Registry Root. Should be used as the RDN. The name shall be "Unique AE Titles Registry".</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_1442072a-4e3e-4879-8694-efcc52a779c4">Description</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_1e252efc-ec85-495c-a3af-85a48859ca42">0..1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_828c7508-0f41-43f0-9778-b36eef4b7b7c">Unconstrained text description.</para>
                </td>
              </tr>
            </tbody>
          </table>
          <table frame="box" label="H.1-13" rules="all" xml:id="table_H.1-13">
            <caption>Child Objects of Unique AE Titles Registry Root Object</caption>
            <thead>
              <tr valign="top">
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_ecd7e31e-b343-4480-b820-1cc1f42c4b2d">Information Field</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_e467aa9d-7772-4261-a1ae-91541d230c29">Multiplicity</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_384a17d9-a6bc-451a-8566-1e6564455413">Description</para>
                </th>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_e8196f0d-fe2e-4f70-a761-bb6ca714a86d">Unique AE Title</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_ee9febbc-85cd-40df-b8cf-bed8dfc84854">0..N</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_11fbe637-b923-4690-9cce-c735f827223a">The unique AE Titles installed within this organizational domain (see <xref linkend="sect_H.1.1.8" xrefstyle="select: label"/>)</para>
                </td>
              </tr>
            </tbody>
          </table>
        </section>
        <section label="H.1.1.8" status="4" xml:id="sect_H.1.1.8">
          <title>Unique AE Title</title>

          <para xml:id="para_cf846c01-64b7-4a2d-afcf-d2a09b19c301">This structural object class represents a Unique Application Entity Title. Objects of this type should only exist as children of the Unique AE-Titles Registry Root. The sole purpose of this object class is to enable allocation of unique AE Titles. All operational information associated with an AE Title is maintained within a separate Network AE object.</para>
          <table frame="box" label="H.1-14" rules="all" xml:id="table_H.1-14">
            <caption>Attributes of the Unique AE Title Object</caption>
            <thead>
              <tr valign="top">
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_dbc2876e-76f0-4bd8-8c34-3762514ea07e">Information Field</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_e2649d4f-b0ef-4dd3-93cb-c72bd458d3cc">Multiplicity</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_a6f3f63c-043e-4a85-9216-5401d9c37a4a">Description</para>
                </th>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_dceeea18-20f2-4f9e-a172-ced1d1f91135">AE Title</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_c589431c-415b-4593-bb68-cfaa6bc5b2e4">1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_e1f33fb5-9650-4d8c-9625-7e0c96727754">The Unique AE Titles.</para>
                </td>
              </tr>
            </tbody>
          </table>
        </section>
      </section>
<section label="H.1.2" status="3" xml:id="sect_H.1.2">
    <title>Application Configuration Data Model Hierarchy</title>
  
  <para xml:id="para_98f6fcb1-6d47-4ca4-b592-cc56df4b74e6">The LDAP structure is built upon a hierarchy of named objects. This hierarchy can vary from site to site. The DICOM configuration management function needs to find its objects within this hierarchy in a predictable manner. For this reason, three specific object classes are defined for the three objects at the top of the DICOM hierarchy. These three object classes must not be used in this tree relationship anywhere else in the LDAP hierarchy.</para>
  <para xml:id="para_69e737a1-218e-4133-bacf-4f2c8b104cb2">The DICOM portion of the hierarchy shall begin at a root object of class dicomConfigurationRoot with a Common Name of "DICOM Configuration". Below this object shall be two other objects:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_916e824f-6c0f-4496-a0cd-a76159da3046">An object of class dicomDevicesRoot with a Common Name of "Devices". This is the root of the tree of objects that correspond to the Application Configuration Data Model structure of <xref linkend="sect_H.1.1" xrefstyle="select: label"/>.</para>
</listitem>
<listitem>
<para xml:id="para_6f4fa23c-27cb-40c2-b680-17014cc66d26">An object of class dicomUniqueAETitlesRegistryRoot with a common name of "Unique AE Titles Registry". This is the root of a flat tree of objects. Each of these objects is named with one of the AE titles that are presently assigned. This is the mechanism for finding available AE titles.</para>
</listitem>
</orderedlist>
  <para xml:id="para_7f7457f9-aec3-4668-9871-93d3eb37e5c2">The three object classes dicomConfigurationRoot, dicomDevicesRoot, and dicomUniqueAETitleRegistryRoot are used by LDAP clients to establish the local root of the DICOM configuration information within an LDAP hierarchy that may be used for many other purposes.</para>
  <note>
    <para xml:id="para_03bdc62c-dfc4-46fd-a81d-b676fbc9ea66">During system startup it is likely that the DICOM configuration application will do an LDAP search for an entry of object class dicomConfigurationRoot and then confirm that it has the dicomDevicesRoot and dicomUniqueAETitlesRegistryRoot entries directly below it. When it finds this configuration, it can then save the full location within the local LDAP tree and use that as the root of the DICOM tree.</para>
  </note>
  <para xml:id="para_d9b13f27-d258-4ab4-8f4d-1c61974e2217">The objects underneath the dicomUniqueAETitlesRegistryRoot are used to provide the uniqueness required for DICOM AE-titles. The dicomUniqueAETitle objects have a single attribute representing a unique AE Title. When a new AE-Title is required, a tentative new name is selected. The new name is reserved by using the LDAP create facility to create an object of class dicomUniqueAETitle with the new name under the AE-Title object. If this name is already in use, the create will fail. Otherwise, this reserves the name. LDAP queries can be used to obtain the list of presently assigned AE-titles by obtaining the list of all names under the dicomUniqueAETitlesRegistryRoot object.</para>
  <para xml:id="para_ce78e0b3-8f79-4d89-afa1-35d81ed7737f">
  <figure label="H.1-2" pgwide="1" xml:id="figure_H.1-2">
    <title>DICOM Configuration Hierarchy</title>
    <mediaobject>
      <imageobject>
        <imagedata fileref="figures/PS3.15_H.1-2.svg"/>
        <!--<imagedata fileref="part15_fromword_files/image024.png"/>-->
      </imageobject>
    </mediaobject>
  </figure>
</para>
  <note>
    <orderedlist>
      <listitem>
        <para xml:id="para_9b065195-53e2-4b52-82fd-66ae961484d2">LDAP uses a root and relative hierarchical naming system for objects. Every object name is fully unique within the full hierarchy. This means that the names of the objects beneath "Unique AE Titles Registry" will be unique. It also means that the full names of Network AEs and Connections will be within their hierarchy context. E.g., the DN for one of the Network AEs in <xref linkend="figure_H.1-2" xrefstyle="select: label"/> would be:</para>
        <itemizedlist mark="none">
          <listitem>
<para xml:id="para_1b95f570-f120-48f8-ad75-a956f852af87">dicomAETitle=CT_01, dicomDeviceName=Special Research CT, cn=Devices, cn=DICOM Configuration, o=Sometown Hospital</para>
</listitem>
        </itemizedlist>
      </listitem>
      <listitem>
<para xml:id="para_2bc41076-b928-4f67-bec7-ec5d4f8181c2">In theory, multiple independent DICOM configuration hierarchies could exist within one organization. The LDAP servers in such a network should constrain local device accesses so that DICOM configuration clients have only one DICOM Configuration Hierarchy visible to each client.</para>
      </listitem>
      <listitem>
<para xml:id="para_96aa21b3-c784-48a5-b18f-c1ce6ba99a12">The merger of two organizations will require manual configuration management to merge DICOM Configuration hierarchies. There are likely to be conflicts in AE-titles, roles, and other conflicts.</para>
      </listitem>
    </orderedlist>
  </note>
      </section>
<section label="H.1.3" status="3" xml:id="sect_H.1.3">
    <title>LDAP Schema For Objects and Attributes</title>
  
  <para xml:id="para_9f327dca-ccb2-4e61-aa40-5578bcf5ae12">The individual LDAP attribute information is summarized in the comments at the beginning of the schema below. The formal definition of the objects and the attributes is in the schema below. This schema may be extended by defining an additional schema that defines auxiliary classes, sub-classes derived from this schema, or both.</para>
  <para xml:id="para_ecbe5fce-85e9-4c86-93e5-66dedbf435c3">The formal LDAP schema for the Application Configuration Data Model and the DICOM Configuration Hierarchy is:</para>
  <programlisting><![CDATA[# 3 Attribute Type Definitions
# 
#    The following attribute types are defined in this document:
# 
#	Name                                    Syntax    Multiplicity
#	--------------------------------        ------    ------------
#	dicomDeviceName                         string    Single
#	dicomDescription                        string    Single
#	dicomManufacturer                       string    Single
#	dicomManufacturerModelName              string    Single
#	dicomSoftwareVersion                    string    Multiple
#	dicomVendorData                         binary    Multiple
#	dicomAETitle                            string    Single
#	dicomNetworkConnectionReference         DN        Multiple
#	dicomApplicationCluster                 string    Multiple
#	dicomAssociationInitiator               bool      Single
#	dicomAssociationAcceptor                bool      Single
#	dicomHostname                           string    Single
#	dicomPort                               integer   Single
#	dicomSOPClass                           OID       Single
#	dicomTransferRole                       string    Single
#	dicomTransferSyntax                     OID       Multiple
#	dicomPrimaryDeviceType                  string    Multiple
#	dicomRelatedDeviceReference             DN        Multiple
#	dicomPreferredCalledAETitle             string    Multiple
#	dicomTLSCipherSuite                     string    Multiple
#	dicomAuthorizedNodeCertificateReference DN        Multiple
#	dicomThisNodeCertificateReference       DN        Multiple
#	dicomInstalled                          bool      Single
#	dicomStationName                        string    Single
#	dicomDeviceSerialNumber                 string    Single
#	dicomInstitutionName                    string    Multiple
#	dicomInstitutionAddress                 string    Multiple
#	dicomInstitutionDepartmentName          string    Multiple
#	dicomIssuerOfPatientID                  string    Single
#	dicomPreferredCallingAETitle            string    Multiple
#	dicomSupportedCharacterSet              string    Multiple
#	dicomInstitutionDepartmentType          string    Multiple
#


# 3.1 dicomDeviceName                     string    Single
# 
#    This attribute stores the unique name (within the scope of the LDAP database) 
#    for a DICOM Device.
#
#    It is a single-valued attribute. 
#    This attribute's syntax is 'Directory String'.
#    Its case is not significant for equality and substring matches.
# 
attributetype ( 1.2.840.10008.15.0.3.1
	NAME 'dicomDeviceName'
	DESC 'The unique name for the device'
	EQUALITY caseIgnoreMatch
	SUBSTR caseIgnoreSubstringsMatch
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.15
	SINGLE-VALUE )

# 3.2 dicomDescription                    string    Single
# 
#    This attribute stores the (unconstrained) textual description for a DICOM entity.
#
#    It is a single-valued attribute. 
#    This attribute's syntax is 'Directory String'.
#    Its case is not significant for equality and substring matches.
# 
attributetype ( 1.2.840.10008.15.0.3.2
	NAME 'dicomDescription'
	DESC 'Textual description of the DICOM entity'
	EQUALITY caseIgnoreMatch
	SUBSTR caseIgnoreSubstringsMatch
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.15
	SINGLE-VALUE )

# 3.3 dicomManufacturer                   string    Single
#
#    This attribute stores the Manufacturer name for a DICOM Device.
#    Should be identical to the Value of the DICOM attribute Manufacturer (0008,0070) [VR=LO]
#    contained in SOP Instances created by this device.
#
#    It is a single-valued attribute. 
#    This attribute's syntax is 'Directory String'.
#    Its case is not significant for equality and substring matches.
#
attributetype ( 1.2.840.10008.15.0.3.3
	NAME 'dicomManufacturer'
	DESC 'The device Manufacturer name'
	EQUALITY caseIgnoreMatch
	SUBSTR caseIgnoreSubstringsMatch
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.15
	SINGLE-VALUE )

# 3.4 dicomManufacturerModelName          string    Single
#
#    This attribute stores the Manufacturer Model Name for a DICOM Device.
#    Should be identical to the Value of the DICOM attribute Manufacturer 
#    Model Name (0008,1090) [VR=LO]
#    contained in SOP Instances created by this device.
#
#    It is a single-valued attribute. 
#    This attribute's syntax is 'Directory String'.
#    Its case is not significant for equality and substring matches.
#
attributetype ( 1.2.840.10008.15.0.3.4
	NAME 'dicomManufacturerModelName'
	DESC 'The device Manufacturer Model Name'
	EQUALITY caseIgnoreMatch
	SUBSTR caseIgnoreSubstringsMatch
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.15
	SINGLE-VALUE )

# 3.5 dicomSoftwareVersion                string    Multiple
#
#    This attribute stores the software version of the device and/or its subcomponents.
#    Should be the same as the Values of Software Versions (0018,1020) in 
#    SOP instances created by this device.
#
#    It is a multi-valued attribute. 
#    This attribute's syntax is 'Directory String'.
#    Its case is not significant for equality and substring matches.
#
attributetype ( 1.2.840.10008.15.0.3.5
	NAME 'dicomSoftwareVersion'
	DESC 'The device software version. Should be the same as the Values of Software
	      Versions (0018,1020) in SOP instances created by this device.'
	EQUALITY caseIgnoreMatch
	SUBSTR caseIgnoreSubstringsMatch
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.15 )

# 3.6 dicomVendorData                     binary    Multiple
#
#    This attribute stores vendor specific configuration information.
#
#    It is a multi-valued attribute. 
#    This attribute's syntax is 'Binary'.
#    Neither equality nor substring matches are applicable to binary data.
#
attributetype ( 1.2.840.10008.15.0.3.6
	NAME 'dicomVendorData'
	DESC 'Arbitrary vendor-specific configuration information (binary data)'
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.5 )

# 3.7 dicomAETitle                        name      Single
#
#    This attribute stores an Application Entity (AE) title.
#
#    It is a single-valued attribute. 
#    This attribute's syntax is 'IA5 String'.
#    Its case is significant.
#
attributetype ( 1.2.840.10008.15.0.3.7
	NAME 'dicomAETitle'
	DESC 'Application Entity (AE) title'
	EQUALITY caseExactIA5Match
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.26
	SINGLE-VALUE )

# 3.8 dicomNetworkConnectionReference     DN        Multiple
# 
#    This attribute stores the DN of a dicomNetworkConnection object 
#    used by an Application Entity.
#
#    It is a multi-valued attribute. 
#    This attribute's syntax is 'Distinguished Name'.
# 
attributetype ( 1.2.840.10008.15.0.3.8
	NAME 'dicomNetworkConnectionReference'
	DESC 'The DN of a dicomNetworkConnection object used by an Application Entity'
	EQUALITY distinguishedNameMatch
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.12 )

# 3.9 dicomApplicationCluster             string    Multiple
#
#    This attribute stores an application cluster name for an Application 
#    Entity (e.g., "Neuroradiology Research")
#
#    It is a multi-valued attribute. 
#    This attribute's syntax is 'Directory String'.
#    Its case is not significant for equality and substring matches.
# 
attributetype ( 1.2.840.10008.15.0.3.9
	NAME 'dicomApplicationCluster'
	DESC 'Application cluster name for an Application Entity (e.g., "Neuroradiology Research")'
	EQUALITY caseIgnoreMatch
	SUBSTR caseIgnoreSubstringsMatch
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.15 )

# 3.10 dicomAssociationInitiator          bool      Single
#
#    This attribute indicates if an Application Entity is capable of initiating 
#    network associations.
#
#    It is a single-valued attribute. 
#    This attribute's syntax is 'Boolean'.
# 
attributetype ( 1.2.840.10008.15.0.3.10
	NAME 'dicomAssociationInitiator'
	DESC 'Indicates if an Application Entity is capable of initiating network associations'
	EQUALITY booleanMatch 
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.7
	SINGLE-VALUE )

# 3.11 dicomAssociationAcceptor           bool      Single
#
#    This attribute indicates if an Application Entity is capable of accepting 
#    network associations.
#
#    It is a single-valued attribute. 
#    This attribute's syntax is 'Boolean'.
# 
attributetype ( 1.2.840.10008.15.0.3.11
	NAME 'dicomAssociationAcceptor'
	DESC 'Indicates if an Application Entity is capable of accepting network associations'
	EQUALITY booleanMatch 
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.7
	SINGLE-VALUE )

# 3.12 dicomHostname                      string    Single
#
#    This attribute stores a DNS hostname for a connection.
#
#    It is a single-valued attribute. 
#    This attribute's syntax is 'Directory String'.
#    Its case is not significant for equality and substring matches.
#
attributetype ( 1.2.840.10008.15.0.3.12
	NAME 'dicomHostname'
	DESC 'DNS hostname'
	EQUALITY caseIgnoreMatch
	SUBSTR caseIgnoreSubstringsMatch
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.15
	SINGLE-VALUE )

# 3.13 dicomPort                          integer   Single
#
#    This attribute stores a TCP port number for a connection.
#
#    It is a single-valued attribute. 
#    This attribute's syntax is 'Integer'.
#
attributetype ( 1.2.840.10008.15.0.3.13
	NAME 'dicomPort'
	DESC 'TCP Port number'
	EQUALITY  integerMatch
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.27
	SINGLE-VALUE )

# 3.14 dicomSOPClass                      OID       Single
#
#    This attribute stores a SOP Class UID
#
#    It is a single-valued attribute. 
#    This attribute's syntax is 'OID'.
#
attributetype ( 1.2.840.10008.15.0.3.14
	NAME 'dicomSOPClass'
	DESC 'A SOP Class UID'
	EQUALITY  objectIdentifierMatch
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.38
	SINGLE-VALUE )

# 3.15 dicomTransferRole                  String    Single
#
#    This attribute stores a transfer role (either "SCU" or "SCP").
#
#    It is a single-valued attribute. 
#    This attribute's syntax is 'Directory String'.
#    Its case is not significant for equality and substring matches.
#
attributetype ( 1.2.840.10008.15.0.3.15
	NAME 'dicomTransferRole'
	DESC 'Transfer role (either "SCU" or "SCP")'
	EQUALITY caseIgnoreMatch
	SUBSTR caseIgnoreSubstringsMatch
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.15
	SINGLE-VALUE )

# 3.16 dicomTransferSyntax                OID       Multiple
#
#    This attribute stores a Transfer Syntax UID
#
#    It is a multi-valued attribute. 
#    This attribute's syntax is 'OID'.
#
attributetype ( 1.2.840.10008.15.0.3.16
	NAME 'dicomTransferSyntax'
	DESC 'A Transfer Syntax UID'
	EQUALITY  objectIdentifierMatch
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.38 )

# 3.17 dicomPrimaryDeviceType             string    Multiple
#	
#    This attribute stores the primary type for a DICOM Device. 
#    Types should be selected from the list of code values (0008,0100) 
#    for Context ID 30 in DICOM Part 16 when applicable. 
#
#    It is a multiple-valued attribute. 
#    This attribute's syntax is 'IA5 String'.
#    Its case is significant.
#
attributetype ( 1.2.840.10008.15.0.3.17
	NAME 'dicomPrimaryDeviceType'
	DESC 'The device Primary Device type'
	EQUALITY caseExactIA5Match
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.26 )

# 3.18 dicomRelatedDeviceReference        DN        Multiple
#
#    This attribute stores a reference to a related device description outside 
#    the DICOM Configuration Hierachy. Can be used to link the DICOM Device object to 
#    additional LDAP objects instantiated from other schema and used for 
#    separate administrative purposes. 
#
#    This attribute's syntax is 'Distinguished Name'.
#    It is a multiple-valued attribute. 
#
attributetype ( 1.2.840.10008.15.0.3.18
	NAME 'dicomRelatedDeviceReference'
	DESC 'The DN of a related device description outside the DICOM Configuration Hierachy'
	EQUALITY distinguishedNameMatch
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.12 )

# 3.19 dicomPreferredCalledAETitle        string    Multiple
#
#    AE Title(s) to which associations may be preferably initiated. 
#
#    It is a multiple-valued attribute. 
#    This attribute's syntax is 'IA5 String'.
#    Its case is significant.
#
attributetype ( 1.2.840.10008.15.0.3.19
	NAME 'dicomPreferredCalledAETitle'
	DESC 'AE Title(s) to which associations may be preferably initiated.'
	EQUALITY caseExactIA5Match
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.26 )

# 3.20 dicomTLSCipherSuite                string    Multiple
#
#    The attribute stores the supported TLS CipherSuites.
#    TLS CipherSuites shall be described using a RFC-2246 string representation 
#    (e.g., "TLS_RSA_WITH_RC4_128_SHA").
#
#    It is a multiple-valued attribute. 
#    This attribute's syntax is 'IA5 String'.
#    Its case is significant.
# 
attributetype ( 1.2.840.10008.15.0.3.20
	NAME 'dicomTLSCipherSuite'
	DESC 'The supported TLS CipherSuites'
	EQUALITY caseExactIA5Match
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.26 )

# 3.21  dicomAuthorizedNodeCertificateReference DN Multiple
#
#    This attribute stores a reference to a TLS public certificate for a DICOM
#    node that is authorized to connect to this node. The certificate 
#    is not necessarily stored within the DICOM Hierarchy
#
#    This attribute's syntax is 'Distinguished Name'.
#    It is a multiple-valued attribute. 
#
attributetype ( 1.2.840.10008.15.0.3.21
	NAME 'dicomAuthorizedNodeCertificateReference'
	DESC 'The DN of a Certificate for a DICOM node that is authorized to connect to this node'
	EQUALITY distinguishedNameMatch
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.12 )

# 3.22 dicomThisNodeCertificateReference DN Multiple
#
#    This attribute stores a reference to a TLS public certificate for
#    this node. It is not necessarily stored as part of
#    the DICOM Configuration Hierachy.
#
#    This attribute's syntax is 'Distinguished Name'.
#    It is a multiple-valued attribute. 
#
attributetype ( 1.2.840.10008.15.0.3.22
	NAME 'dicomThisNodeCertificateReference'
	DESC 'The DN of a related device description outside the DICOM Configuration Hierachy'
	EQUALITY distinguishedNameMatch
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.12 )

# 3.23 dicomInstalled                     bool      Single
#
#    This attribute indicates whether the object is presently installed.
#
#    It is a single-valued attribute. 
#    This attribute's syntax is 'Boolean'.
# 
attributetype ( 1.2.840.10008.15.0.3.23
	NAME 'dicomInstalled'
	DESC 'Indicates if the DICOM object (device, Network AE, or Port) is presently installed'
	EQUALITY booleanMatch 
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.7
	SINGLE-VALUE )

# 3.24	dicomStationName                  string    Single
#
#    This attribute stores the station name of the device.
#    Should be the same as the value of Station Name (0008,1010) in 
#    SOP instances created by this device.
#
#    It is a single-valued attribute.
#    This attribute's syntax is 'Directory String'.
# 
attributetype ( 1.2.840.10008.15.0.3.24
	NAME 'dicomStationName'
	DESC 'Station Name of the device. Should be the same as the value of Station
	      Name (0008,1010) in SOP instances created by this device.'
	EQUALITY caseIgnoreMatch
	SUBSTR caseIgnoreSubstringsMatch
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.15
	SINGLE-VALUE)

# 3.25	dicomDeviceSerialNumber           string    Single
#
#    This attribute stores the serial number of the device.
#    Should be the same as the value of Device Serial Number (0018,1000) 
#    in SOP instances created by this device.
#
#    It is a single-valued attribute.
#    This attribute's syntax is 'Directory String'.
# 
attributetype ( 1.2.840.10008.15.0.3.25
	NAME 'dicomDeviceSerialNumber'
	DESC 'Serial number of the device. Should be the same as the value of Device Serial
	      Number (0018,1000) in SOP instances created by this device.'
	EQUALITY caseIgnoreMatch
	SUBSTR caseIgnoreSubstringsMatch
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.15
	SINGLE-VALUE)

# 3.26	dicomInstitutionName              string    Multiple
#
#    This attribute stores the institution name of the device.
#    Should be the same as the value of Institution Name (0008,0080) 
#    in SOP Instances created by this device.
#
#    It is a multi-valued attribute.
#    This attribute's syntax is 'Directory String'.
# 
attributetype ( 1.2.840.10008.15.0.3.26
	NAME 'dicomInstitutionName'
	DESC 'Institution name of the device. Should be the same as the value of Institution
	      Name (0008,0080) in SOP Instances created by this device.'
	EQUALITY caseIgnoreMatch
	SUBSTR caseIgnoreSubstringsMatch
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.15 )

# 3.27	dicomInstitutionAddress           string    Multiple
#
#    This attribute stores the institution address of the device.
#    Should be the same as the value of Institution Address (0008,0081) 
#    attribute in SOP Instances created by this device.
#
#    It is a multi-valued attribute.
#    This attribute's syntax is 'Directory String'.
# 
attributetype ( 1.2.840.10008.15.0.3.27
	NAME 'dicomInstitutionAddress'
	DESC 'Institution address of the device. Should be the same as the value of Institution
	      Address (0008,0081) attribute in SOP Instances created by this device.'
	EQUALITY caseIgnoreMatch
	SUBSTR caseIgnoreSubstringsMatch
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.15 )

# 3.28	dicomInstitutionDepartmentName    string   Multiple
#
#    This attribute stores the institution department name of the device. 
#    Should be the same as the value of Institutional Department Name (0008,1040) 
#    in SOP Instances created by this device.
#
#    It is a multi-valued attribute.
#    This attribute's syntax is 'Directory String'.
# 
attributetype ( 1.2.840.10008.15.0.3.28
	NAME 'dicomInstitutionDepartmentName'
	DESC 'Institution department name of the device. Should be the same as the value of Institutional
	      Department Name (0008,1040) in SOP Instances created by this device.'
	EQUALITY caseIgnoreMatch
	SUBSTR caseIgnoreSubstringsMatch
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.15 )

# 3.29	dicomIssuerOfPatientID            string    Single
#
#    This attribute stores the Default value for the Issuer of Patient ID (0010,0021) 
#    for SOP Instances created by this device. May be overridden by the values 
#    received in a worklist or other source.
#
#    It is a multi-valued attribute.
#    This attribute's syntax is 'Directory String'.
# 
attributetype ( 1.2.840.10008.15.0.3.29
	NAME 'dicomIssuerOfPatientID'
	DESC 'Default value for the Issuer of Patient ID (0010,0021) for SOP Instances created by this device.
	      May be overridden by the values received in a worklist or other source.'
	EQUALITY caseIgnoreMatch
	SUBSTR caseIgnoreSubstringsMatch
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.15 )

# 3.30	dicomPreferredCallingAETitle      string    Multiple
#
#    AE Title(s) to which associations may be preferably accepted. 
#
#    It is a multiple-valued attribute. 
#    This attribute's syntax is 'IA5 String'.
#    Its case is significant.
#
attributetype ( 1.2.840.10008.15.0.3.30
	NAME 'dicomPreferredCallingAETitle'
	DESC 'AE Title(s) to which associations may be preferably accepted.'
	EQUALITY caseExactIA5Match
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.26 )

# 3.31	dicomSupportedCharacterSet        string    Multiple
#
#    The Character Set(s) supported by the Network AE for Data Sets it receives. 
#    Contains one of the Defined Terms for Specific Character Set (0008,0005). 
#    If not present, this implies that the Network AE supports only the default 
#    character repertoire (ISO IR 6). 
#
#    It is a multiple-valued attribute. 
#    This attribute's syntax is 'IA5 String'.
#    Its case is significant.
#
attributetype ( 1.2.840.10008.15.0.3.31
	NAME 'dicomSupportedCharacterSet'
	DESC 'The Character Set(s) supported by the Network AE for Data Sets it receives.'
	EQUALITY caseExactIA5Match
	SYNTAX 1.3.6.1.4.1.1466.115.121.1.26 )

# 3.31 dicomInstitutionDepartmentType    string   Multiple
#
#    This attribute stores the institution department type of the device. 
#    Should be the same as the value of Institutional Department Type Code 
#    Sequence (0008,1041) in SOP Instances created by this device.
#    Types should be selected from the list of code values (0008,0100) 
#    for Context ID 7030 in DICOM Part 16 when applicable. 
#
#    It is a multi-valued attribute.
#    This attribute's syntax is 'IA5 String'.
# 
attributetype ( 1.2.840.10008.15.0.3.31
 NAME 'dicomInstitutionDepartmentType'
 DESC 'Institution department type of the device. Should be the same as the value of Institutional
       Department Type Code Sequence (0008,1041) in SOP Instances created by this device.'
 EQUALITY caseIgnoreMatch
 SUBSTR caseIgnoreSubstringsMatch
 SYNTAX 1.3.6.1.4.1.1466.115.121.1.26 )

# 4 Object Class Definitions
# 
#    The following object classes are defined in this document. All are
#    structural classes.
# 
#	Name                            Description
#	---------------------------     --------------------------
#	dicomConfigurationRoot          root of the DICOM Configuration Hierarchy
#	dicomDevicesRoot                root of the DICOM Devices Hierarchy
#	dicomUniqueAETitlesRegistryRoot	root of the Unique DICOM AE-Titles Registry Hierarchy
#	dicomDevice                     Devices
#	dicomNetworkAE                  Network AE
#	dicomNetworkConnection          Network Connections
#	dicomUniqueAETitle              Unique AE Title
#	dicomTransferCapability         Transfer Capability

# 
# 4.1 dicomConfigurationRoot
#
#    This structural object class represents the root of the DICOM Configuration Hierarchy. 
#    Only a single object of this type should exist within an organizational domain.
#    Clients can search for an object of this class to locate the root of the 
#    DICOM Configuration Hierarchy.
#
objectclass ( 1.2.840.10008.15.0.4.1
	NAME 'dicomConfigurationRoot'
	DESC 'Root of the DICOM Configuration Hierarchy'
	SUP top
	STRUCTURAL
	MUST ( cn ) 
	MAY ( description ) )

#
# 4.2 dicomDevicesRoot			
#
#    This structural object class represents the root of the DICOM Devices Hierarchy. 
#    Only a single object of this type should exist as a child of dicomConfigurationRoot.
#
objectclass ( 1.2.840.10008.15.0.4.2
	NAME 'dicomDevicesRoot'
	DESC 'Root of the DICOM Devices Hierarchy'
	SUP top
	STRUCTURAL
	MUST ( cn ) 
	MAY ( description ) )

#
# 4.3 dicomUniqueAETitlesRegistryRoot			
#
#    This structural object class represents the root of the Unique DICOM AE-Titles 
#    Registry Hierarchy. 
#    Only a single object of this type should exist as a child of dicomConfigurationRoot.
#
objectclass ( 1.2.840.10008.15.0.4.3
	NAME 'dicomUniqueAETitlesRegistryRoot'
	DESC 'Root of the Unique DICOM AE-Title Registry Hierarchy'
	SUP top
	STRUCTURAL
	MUST ( cn ) 
	MAY ( description ) )

#
# 4.4 dicomDevice
#
#    This structural object class represents a DICOM Device.
#
objectclass ( 1.2.840.10008.15.0.4.4
	NAME 'dicomDevice'
	DESC 'DICOM Device related information'
	SUP top
	STRUCTURAL
	MUST ( 
		dicomDeviceName $
		dicomInstalled ) 
	MAY  ( 
		dicomDescription $
		dicomManufacturer $
		dicomManufacturerModelName $
		dicomSoftwareVersion $
		dicomStationName $
		dicomDeviceSerialNumber $
		dicomInstitutionName $
		dicomInstitutionAddress $
		dicomInstitutionDepartmentName $
		dicomIssuerOfPatientID $
		dicomVendorData $
		dicomPrimaryDeviceType $
		dicomRelatedDeviceReference $
		dicomAuthorizedNodeCertificateReference $
		dicomThisNodeCertificateReference) )

#
# 4.5 dicomNetworkAE
#
#    This structural object class represents a Network Application Entity
#
objectclass ( 1.2.840.10008.15.0.4.5
	NAME 'dicomNetworkAE'
	DESC 'DICOM Network AE related information'
	SUP top
	STRUCTURAL
	MUST (
		dicomAETitle $ 
		dicomNetworkConnectionReference $
		dicomAssociationInitiator $
		dicomAssociationAcceptor )
	MAY ( 
		dicomDescription $
		dicomVendorData $
		dicomApplicationCluster $
		dicomPreferredCalledAETitle $
		dicomPreferredCallingAETitle $
		dicomSupportedCharacterSet $
		dicomInstalled ) )

#
# 4.6 dicomNetworkConnection
#
#    This structural object class represents a Network Connection
#
objectclass ( 1.2.840.10008.15.0.4.6
	NAME 'dicomNetworkConnection'
	DESC 'DICOM Network Connection information'
	SUP top
	STRUCTURAL
	MUST ( dicomHostname )
	MAY ( 
		cn $
		dicomPort $
		dicomTLSCipherSuite $
		dicomInstalled ) )

#
# 4.7 dicomUniqueAETitle
#
#    This structural object class represents a Unique Application Entity Title
#
objectclass ( 1.2.840.10008.15.0.4.7
	NAME 'dicomUniqueAETitle'
	DESC 'A Unique DICOM Application Entity title'
	SUP top
	STRUCTURAL
	MUST ( dicomAETitle ) )

#
# 4.8 dicomTransferCapability
#
#    This structural object class represents Transfer Capabilities for an Application Entity
#
objectclass ( 1.2.840.10008.15.0.4.8
	NAME 'dicomTransferCapability'
	DESC 'Transfer Capabilities for an Application Entity'
	SUP top
	STRUCTURAL
	MUST (
		dicomSOPClass $
		dicomTransferRole $
		dicomTransferSyntax)
	MAY (
		cn) )
]]>
  </programlisting>
</section>
<section label="H.1.4" status="3" xml:id="sect_H.1.4">
    <title>Transactions</title>
  
  <section label="H.1.4.1" status="4" xml:id="sect_H.1.4.1">
    <title>Find LDAP Server</title>
  
  <section label="H.1.4.1.1" status="5" xml:id="sect_H.1.4.1.1">
    <title>Scope</title>
  
  <para xml:id="para_43a6bd97-ebe9-4467-977d-9545c4190e6f">The <xref linkend="biblio_RFC_2782"/>
  <emphasis role="italic">A DNS RR for specifying the location of services (DNS SRV)</emphasis> specifies a mechanism for requesting the names and rudimentary descriptions for machines that provide network services. The DNS client requests the descriptions for all machines that are registered as offering a particular service name. In this case the service name requested will be "LDAP". The DNS server may respond with multiple names for a single request.</para>
  </section>
<section label="H.1.4.1.2" status="5" xml:id="sect_H.1.4.1.2">
    <title>Use Case Roles</title>
  
  <para xml:id="para_73d0a038-a358-4b03-81c4-72400f4408e6">
  <figure label="H.1-3" pgwide="1" xml:id="figure_H.1-3">
    <title>Find LDAP Server</title>
    <mediaobject>
      <imageobject>
        <imagedata fileref="figures/PS3.15_H.1-3.svg"/>
        <!--<imagedata fileref="part15_fromword_files/image026.png"/>-->
      </imageobject>
    </mediaobject>
  </figure>
</para>
  <variablelist>
    <varlistentry>
<term>DNS Server</term>
<listitem>
<para xml:id="para_4b80c8d5-8cf5-4fce-943e-b7e32e543bd3">Provides list of LDAP servers</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>LDAP Client</term>
<listitem>
<para xml:id="para_fb3de24a-c8dc-440b-b461-8a86964696ee">Requests list of LDAP servers</para>
</listitem>
</varlistentry>
  </variablelist>
</section>
<section label="H.1.4.1.3" status="5" xml:id="sect_H.1.4.1.3">
    <title>Referenced Standards</title>
  
  <para xml:id="para_21519421-9bbd-43c4-8a9d-7e77acdf3fed">
<xref linkend="biblio_RFC_2181"/> Clarifications to the DNS Specification</para>
  <para xml:id="para_c87570e3-9cb4-419f-9777-f86fa994c119">
<xref linkend="biblio_RFC_2219"/> Use of DNS Aliases for Network Services</para>
  <para xml:id="para_00f1248d-93f5-4f70-a269-a1b64eeef77a">
<xref linkend="biblio_RFC_2782"/> A DNS RR for specifying the location of services (DNS SRV)</para>
  <para xml:id="para_482df8e0-6222-4ddf-82df-1ee6ff74d8d5">other RFCs are included by reference from <xref linkend="biblio_RFC_2181"/>, <xref linkend="biblio_RFC_2219"/>, and <xref linkend="biblio_RFC_2782"/>.</para>
  </section>
<section label="H.1.4.1.4" status="5" xml:id="sect_H.1.4.1.4">
    <title>Interaction Diagram</title>
  
  <para xml:id="para_c2bf63a0-b9e8-447b-ada2-a1c91142600a">
  <figure label="H.1-4" pgwide="1" xml:id="figure_H.1-4">
    <title>Select LDAP Server</title>
    <mediaobject>
      <imageobject>
        <imagedata fileref="figures/PS3.15_H.1-4.svg"/>
        <!--<imagedata fileref="part15_fromword_files/image028.png"/>-->
      </imageobject>
    </mediaobject>
  </figure>
</para>
  <para xml:id="para_27f13bd9-56d6-4e79-8a83-e0bc1dbd34eb">The DNS client shall request a list of all the LDAP servers available. It will use the priority, capacity, and location information provided by DNS to select a server (<xref linkend="biblio_RFC_2782"/> recommends the proper use of these parameters). It is possible that there is no LDAP server, or that the DNS server does not support the SRV RR request.</para>
  <note>
    <orderedlist numeration="arabic">
      <listitem>
        <para xml:id="para_09bc1ec2-c99c-4e41-bb8b-c5648e472aa1">Multiple LDAP servers providing access to a common replicated LDAP database is a commonly supported configuration. This permits LDAP servers to be located where appropriate for best performance and fault tolerance. The DNS server response information provides guidance for selecting the most appropriate server.</para>
      </listitem>
      <listitem>
        <para xml:id="para_17dd1ac4-58d1-493c-b01f-6474ac867966">There may also be multiple LDAP servers providing different databases. In this situation the client may have to examine several servers to find the one that supports the DICOM configuration database. Similarly a single LDAP server may support multiple base DNs, and the client will need to check each of these DNs to determine which is the DICOM supporting tree.</para>
      </listitem>
    </orderedlist>
  </note>
  </section>
<section label="H.1.4.1.5" status="5" xml:id="sect_H.1.4.1.5">
    <title>Alternative Paths</title>
  
  <para xml:id="para_6d297537-19e2-4a27-a099-f0c9a1bfec3f">The client may have a mechanism for manual default selection of the LDAP server to be used if the DNS server does not provide an LDAP server location.</para>
  </section>
</section>
<section label="H.1.4.2" status="4" xml:id="sect_H.1.4.2">
    <title>Query LDAP Server</title>
  
  <section label="H.1.4.2.1" status="5" xml:id="sect_H.1.4.2.1">
    <title>Scope</title>
  
  <para xml:id="para_6c144d7a-eacb-4830-b1ea-b4b06ac9c8e3">The <xref linkend="biblio_RFC_2251"/> "Lightweight Directory Access Protocol (v3)" specifies a mechanism for making queries of a database corresponding to an LDAP schema. The LDAP client can compose requests in the LDAP query language, and the LDAP server will respond with the results for a single request.</para>
  </section>
<section label="H.1.4.2.2" status="5" xml:id="sect_H.1.4.2.2">
    <title>Use Case Roles</title>
  
  <para xml:id="para_9da57e03-9651-4d6f-a60a-f3df136b93fa">
  <figure label="H.1-5" pgwide="1" xml:id="figure_H.1-5">
    <title>Query LDAP Server</title>
    <mediaobject>
      <imageobject>
        <imagedata fileref="figures/PS3.15_H.1-5.svg"/>
        <!--<imagedata fileref="part15_fromword_files/image030.png"/>-->
      </imageobject>
    </mediaobject>
  </figure>
</para>
  <variablelist>
    <varlistentry>
<term>LDAP Server</term>
<listitem>
<para xml:id="para_d3578077-f775-44f7-b538-a9760f14cd02">Provides query response</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>LDAP Client</term>
<listitem>
<para xml:id="para_e989c85a-8f70-476a-a7f6-48c6d41fd579">Requests LDAP information</para>
</listitem>
</varlistentry>
  </variablelist>
</section>
<section label="H.1.4.2.3" status="5" xml:id="sect_H.1.4.2.3">
    <title>Referenced Standards</title>
  
  <para xml:id="para_3b5fe4d3-ea86-49af-8b3b-2cf960bc1959">
<xref linkend="biblio_RFC_2251"/> Lightweight Directory Access Protocol (v3). LDAP support requires compliance with other RFCs invoked by reference.</para>
  </section>
<section label="H.1.4.2.4" status="5" xml:id="sect_H.1.4.2.4">
    <title>Interaction Description</title>
  
  <para xml:id="para_0e4cd621-678a-4be6-a417-c84412c5efc9">The LDAP client may make a wide variety of queries and cascaded queries using LDAP. The LDAP client and server shall support the Application Configuration Data Model .</para>
  <note>
    <para xml:id="para_c6f4a098-23ec-4c9b-a99c-eab39c8ca5f3">Multiple LDAP servers providing access to a common replicated LDAP database is a commonly supported configuration. This permits LDAP servers to be located where appropriate for best performance and fault tolerance. The replications rules chosen for the LDAP servers affect the visible data consistency. LDAP permits inconsistent views of the database during updates and replications.</para>
  </note>
  </section>
</section>
<section label="H.1.4.3" status="4" xml:id="sect_H.1.4.3">
    <title>Update LDAP Server</title>
  
  <section label="H.1.4.3.1" status="5" xml:id="sect_H.1.4.3.1">
    <title>Scope</title>
  
  <para xml:id="para_1f53eca9-d8c8-4116-bff0-86c83b772b4d">The <xref linkend="biblio_RFC_2251"/> "Lightweight Directory Access Protocol (v3)" specifies a mechanism for making updates to a database corresponding to an LDAP schema. The LDAP client can compose updates in the LDAP query language, and the LDAP server will respond with the results for a single request. Update requests may be refused for security reasons.</para>
  </section>
<section label="H.1.4.3.2" status="5" xml:id="sect_H.1.4.3.2">
    <title>Use Case Roles</title>
  
  <para xml:id="para_175de3ec-77d5-4132-ab8d-269c7b418eb7">
  <figure label="H.1-6" pgwide="1" xml:id="figure_H.1-6">
    <title>Update LDAP Server</title>
    <mediaobject>
      <imageobject>
        <imagedata fileref="figures/PS3.15_H.1-6.svg"/>
        <!--<imagedata fileref="part15_fromword_files/image032.png"/>-->
      </imageobject>
    </mediaobject>
  </figure>
</para>
  <variablelist>
    <varlistentry>
<term>LDAP Server</term>
<listitem>
<para xml:id="para_7db02b94-5f89-44f1-bbc5-bfea248ad811">Maintains database</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>LDAP Client</term>
<listitem>
<para xml:id="para_367f4823-d015-4fca-8824-03dc0d81fa92">Updates LDAP information</para>
</listitem>
</varlistentry>
  </variablelist>
</section>
<section label="H.1.4.3.3" status="5" xml:id="sect_H.1.4.3.3">
    <title>Referenced Standards</title>
  
  <para xml:id="para_14e48267-aa30-4bcd-8d58-36e0368ae692">
<xref linkend="biblio_RFC_2251"/> Lightweight Directory Access Protocol (v3). LDAP support requires compliance with other RFCs invoked by reference.</para>
  </section>
<section label="H.1.4.3.4" status="5" xml:id="sect_H.1.4.3.4">
    <title>Interaction Description</title>
  
  <para xml:id="para_b83b5b28-bdcb-46c7-92e7-118680c9fde6">The LDAP client may make a request to update the LDAP database. The LDAP client shall support the data model described above. The LDAP server may choose to refuse the update request for security reasons. If the LDAP server permits update requests, is shall support the data model described above.</para>
  <note>
    <para xml:id="para_2c066488-7016-4f43-9607-5cb7c71afe9a">Multiple LDAP servers providing access to a common replicated LDAP database is a commonly supported configuration. This permits LDAP servers to be located where appropriate for best performance and fault tolerance. Inappropriate selection of replication rules in the configuration of the LDAP server will result in failure for AE-title uniqueness when creating the AE-titles objects.</para>
  </note>
  </section>
<section label="H.1.4.3.5" status="5" xml:id="sect_H.1.4.3.5">
    <title>Special Update For Network AE Creation</title>
  
  <para xml:id="para_ba35aa4a-868d-407c-a22f-cbe71c887a49">The creation of a new Network AE requires special action. The following steps shall be followed:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_e5435f08-7d40-4aff-bd6a-aa089d35a7bc">A tentative AE title shall be selected. Various algorithms are possible, ranging from generating a random name to starting with a preset name template and incrementing a counter field. The client may query the Unique AE Titles Registry sub-tree to obtain the complete list of names that are presently in use as part of this process.</para>
</listitem>
<listitem>
<para xml:id="para_837e43f0-6bfb-4088-9be0-1836975eb513">A new Unique AE Title object shall be created in the Unique AE Titles Registry portion of the hierarchy with the tentative name. The LDAP server enforces uniqueness of names at any specific point in the hierarchy.</para>
</listitem>
<listitem>
<para xml:id="para_ce7315d4-d3e9-4d04-8e93-119585e630f2">If the new object creation was successful, this shall be the AE Title used for the new Network AE.</para>
</listitem>
<listitem>
<para xml:id="para_99339cbb-2e18-452a-a2af-74e114753928">If the new object creation fails due to non-unique name, return to a) and select another name.</para>
</listitem>
</orderedlist>
  </section>
</section>
<section label="H.1.4.4" status="4" xml:id="sect_H.1.4.4">
    <title>Maintain LDAP Server</title>
  
  <para xml:id="para_bb119c87-43bb-4ad5-bce8-288ad9ac8014">The LDAP server shall support a separate manual or automated means of maintaining the LDAP database contents. The LDAP server shall support the <xref linkend="biblio_RFC_2849"/> file format mechanism for updating the LDAP database. The LDAP Client or service installation tools shall provide <xref linkend="biblio_RFC_2849"/> formatted files to update LDAP server databases manually. The LDAP server may refuse client network updates for security reasons. If this is the case, then the maintenance process will be used to maintain the LDAP database.</para>
  <para xml:id="para_0bcdca24-d4b0-4656-8382-4f72e5055d4a">The manual update procedures are not specified other than the requirement above that at least the minimal LDAP information exchange file format from <xref linkend="biblio_RFC_2849"/> be supported. The exact mechanisms for transferring this information remain vendor and site specific. In some situations, for example the creation of AE-titles, a purely manual update mechanism may be easier than exchanging files.</para>
  <para xml:id="para_419e1fa2-9f50-4eca-b428-a7532f48496a">The conformance statement shall document the mechanisms available for transferring this information. Typical mechanisms include:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_fd920a08-d75d-4bae-998f-f9ebb7c8609a">floppy disk</para>
</listitem>
<listitem>
<para xml:id="para_075814e2-1785-4fc9-a0fb-c7f3d927de26">CD-R</para>
</listitem>
<listitem>
<para xml:id="para_4bd55317-152d-4eb1-8806-4df068ae3c8f">SSH</para>
</listitem>
<listitem>
<para xml:id="para_8e3c2542-1be6-40ef-9d48-f98fce79d54b">Secure FTP</para>
</listitem>
<listitem>
<para xml:id="para_78965e0d-18a6-44c1-be5f-2cf284a56136">FTP</para>
</listitem>
<listitem>
<para xml:id="para_f3cb6b54-3a1a-47ae-b52b-9d0335b3abf9">email</para>
</listitem>
<listitem>
<para xml:id="para_6c8dfee7-82a8-4fce-8744-0c2be62f0489">HTTPS</para>
</listitem>
</orderedlist>
  <note>
    <orderedlist numeration="arabic">
      <listitem>
        <para xml:id="para_241fba00-1fd8-4d78-9809-f2959badcc26">There are many automated and semi-automatic tools for maintaining LDAP databases. Many LDAP servers provide GUI interfaces and updating tools. The specifics of these tools are outside the scope of DICOM. The LDAP <xref linkend="biblio_RFC_2849"/> requires at least a minimal data exchange capability. There are also XML based tools for creating and maintaining these files.</para>
      </listitem>
      <listitem>
        <para xml:id="para_90e6e85f-66ca-4b3c-978c-21b5d363960f">This mechanism may also be highly effective for preparing a new network installation by means of a single pre-planned network configuration setup rather than individual machine updates.</para>
      </listitem>
    </orderedlist>
  </note>
  </section>
</section>
<section label="H.1.5" status="3" xml:id="sect_H.1.5">
    <title>LDAP Security Considerations (Informative)</title>
  
  <section label="H.1.5.1" status="4" xml:id="sect_H.1.5.1">
    <title>Threat Assessment</title>
  
  <para xml:id="para_eafbd3c6-5174-40c9-9833-fc6d0883537c">The threat and value for the LDAP based configuration mechanisms fall into categories:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_a2a14b26-a87b-4516-a73c-79d9b261111c">AE-uniqueness mechanism</para>
</listitem>
<listitem>
<para xml:id="para_376f50c8-0bf9-4ca0-9ac7-39f09ddf8a8e">Finding (and updating) Network AE descriptions</para>
</listitem>
<listitem>
<para xml:id="para_5ad6120f-6322-4d29-a76c-91ebda5d30ed">Finding (and updating) device descriptions</para>
</listitem>
</orderedlist>
  <para xml:id="para_f74a79e4-0643-42a5-a868-27460c074644">These each pose different vulnerabilities to attack. These are:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_2db11e42-4a0b-4298-b61b-add60cb7fcad">Active Attacks</para>
  <orderedlist numeration="arabic">
    <listitem>
<para xml:id="para_f97d6f37-926c-4a8f-b25b-1c5ad945d099">The AE-title uniqueness mechanism could be attacked by creating vast numbers of spurious AE-titles. This could be a Denial of Service (DoS) attack on the LDAP server. It has a low probability of interfering with DICOM operations.</para>
</listitem>
    <listitem>
<para xml:id="para_d31ed3d3-38f1-4109-b82b-4d5880144ed0">The Network AE information could be maliciously updated. This would interfere with DICOM operations by interfering with finding the proper server. It could direct connections to malicious nodes, although the use of TLS authentication for DICOM connections would detect such misdirection. When TLS authentication is in place this becomes a DoS attack.</para>
</listitem>
    <listitem>
<para xml:id="para_e0ce47a3-d873-44f4-8a28-092810ecd7dc">The device descriptions could be maliciously modified. This would interfere with proper device operation.</para>
</listitem>
  </orderedlist>
 </listitem>
    <listitem>
      <para xml:id="para_e4d9c597-6305-42b9-baf0-9e6299df069b">Passive Attacks</para>
      <orderedlist numeration="arabic">
        <listitem>
<para xml:id="para_80f8b9db-82c8-42bc-bbf8-3324d90806e8">There is no apparent value to an attacker in obtaining the current list of AE-titles. This does not indicate where these AE-titles are deployed or on what equipment.</para>
</listitem>
        <listitem>
<para xml:id="para_87ffe37d-290c-419c-86b2-11aefe06fdb4">The Network AE information and device descriptions might be of value in determining the location of vulnerable systems. If it is known that a particular model of equipment from a particular vendor is vulnerable to a specific attack, then the Network AE Information can be used to find that equipment.</para>
</listitem>
      </orderedlist>
    </listitem>
  </orderedlist>
  </section>
<section label="H.1.5.2" status="4" xml:id="sect_H.1.5.2">
    <title>Available LDAP Security Mechanisms</title>
  
  <para xml:id="para_50b87901-fbed-48fd-9108-15349ce5ccd8">The security mechanisms for LDAP are highly variable in actual implementations. They are a mixture of administrative restrictions and protocol implementations. The widely available options for security methods are:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_5867124a-438b-4349-91c5-6f359ea5f116">Anonymous access, where there is no restriction on performing this function over the network.</para>
</listitem>
<listitem>
<para xml:id="para_ae69f3d5-6db5-472f-87ea-1dd178eaa9ed">Basic, where there is a username and password exchange prior to granting access to this function. The exchange is vulnerable to snooping, spoofing, and man in the middle attacks.</para>
</listitem>
<listitem>
<para xml:id="para_463b7dd1-fb94-4930-8057-f5513b506444">TLS, where there is an SSL/TLS exchange during connection establishment.</para>
</listitem>
<listitem>
<para xml:id="para_7bdac09d-751e-4da2-a98f-a863dd73f76f">Manual, where no network access is permitted and the function must be performed manually at the server, or semi-automatically at the server. The semi-automatic means permit the use of independently exchanged files (e.g., via floppy) together with manual commands at the server.</para>
</listitem>
</orderedlist>
  <para xml:id="para_b11acd57-ced3-48e6-9814-3c1b4e73d66f">The categories of functions that may be independently controlled are:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_62e71ac0-459a-4e75-a6d8-1aaebe8c7f9a">Read related, to read, query, or otherwise obtain a portion of the LDAP directory tree</para>
</listitem>
<listitem>
<para xml:id="para_607d748b-d314-4e3b-8515-ea2e0001cbfa">Update related, to modify previously existing objects in the directory tree</para>
</listitem>
<listitem>
<para xml:id="para_b0ba2b43-c67d-480e-abe7-f7551a3c2966">Create, to create new objects in the directory tree.</para>
</listitem>
</orderedlist>
  <para xml:id="para_c058c12d-8a5d-49f7-8a77-a025b1d770a6">Finally, these rules may be applied differently to different subtrees within the overall LDAP structure. The specific details of Access Control Lists (ACLs), functional controls, etc. vary somewhat between different LDAP implementations.</para>
  </section>
<section label="H.1.5.3" status="4" xml:id="sect_H.1.5.3">
    <title>Recommendations (Informative)</title>
  
  <para xml:id="para_897eeef8-48c3-4cbe-9741-bd9484df4b7a">The LDAP server should be able to specify different restrictions for the AE-Title list and for the remainder of the configuration information. To facilitate interoperability, <xref linkend="table_H.1-15" xrefstyle="select: label"/> defines several patterns for access control. They correspond to different assessments of risk for a network environment.</para>
    <table frame="box" label="H.1-15" rules="all" xml:id="table_H.1-15">
    <caption>LDAP Security Patterns</caption>
    <thead>
      <tr valign="top">
        <th align="center" colspan="1" rowspan="1"/>
        <th align="center" colspan="1" rowspan="1">
          <para xml:id="para_d59faf19-d591-4dac-a391-8ac6bbf7a90a">
            <emphasis role="bold">TLS</emphasis>
          </para>
        </th>
        <th align="center" colspan="1" rowspan="1">
          <para xml:id="para_051c4d72-628b-4a14-86df-3da35eb61be6">
            <emphasis role="bold">TLS-Manual</emphasis>
          </para>
        </th>
        <th align="center" colspan="1" rowspan="1">
          <para xml:id="para_0a2b4e22-c366-4afe-b49c-d96c3e97e9d2">
            <emphasis role="bold">Basic</emphasis>
          </para>
        </th>
        <th align="center" colspan="1" rowspan="1">
          <para xml:id="para_4ed20dfc-c9aa-469d-832b-c7aceab6c8ae">
            <emphasis role="bold">Basic-Manual</emphasis>
          </para>
        </th>
        <th align="center" colspan="1" rowspan="1">
          <para xml:id="para_4fa8f764-2e33-49a1-bb08-ed0e180b5be4">
            <emphasis role="bold">Anonymous</emphasis>
          </para>
        </th>
        <th align="center" colspan="1" rowspan="1">
          <para xml:id="para_fb0fddf6-915a-4874-b643-c2bf58c6b6ad">
            <emphasis role="bold">Anonymous-Manual</emphasis>
          </para>
        </th>
      </tr>
      
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3451a1d8-93ff-4283-8f87-5a319023ff25">
          <emphasis role="bold">Read AE-title</emphasis>
        </para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_432575e7-1dcf-48a7-a688-b05038210286">Anonymous, TLS</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1d4e2df0-8f8d-4884-b18e-4f7a57621d49">Anonymous, TLS</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_818e490f-660d-464c-80aa-2037fa5f7ccf">Anonymous, Basic</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_71629628-fb2c-43e2-9a6a-90a7cd5e4ec8">Anonymous, Basic</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_81672f3c-6eb0-4981-8ab8-f30e34a1a797">Anonymous</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_bc5a8cbf-542f-456d-b2a7-76f420ed3c0d">Anonymous</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1769b631-1b01-4f5d-8273-f9d59374a9e2">
          <emphasis role="bold">Create AE-Title</emphasis>
        </para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6dd3fa1f-0643-4bae-a139-591529f5c72c">TLS</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f521043f-1662-478f-a5d0-b7ec2c3cdb23">Manual</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_acd0574d-8c17-4eb4-ae34-1e3cb3104070">Basic</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_de38f076-dd87-4ba7-b115-fd21f40116de">Manual</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_729fe15e-3108-4244-9035-f094e48d1f47">Anonymous</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_649fd6e5-532e-4804-9f7a-a446d3c7c459">Manual</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0f16e62a-06a2-4f19-9a22-12993c5845de">
          <emphasis role="bold">Read Config</emphasis>
        </para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_da026454-0206-43f6-88c0-db64995de01f">TLS</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_988ff471-3936-43d5-9fda-5e4426af5685">TLS</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_2ae6a0a8-2e90-482e-841d-72f3e05dfc6b">Basic</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_139db8d8-3eaf-43b5-a3f1-de423ff81b75">Basic</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d30757b1-56f3-46dc-af41-d4c8c20bc122">Anonymous</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a12999fb-d894-4c97-a70b-755e8f59bc8c">Anonymous</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b10fe349-028e-4142-9846-c1bc4e11afd1">
          <emphasis role="bold">Update Config</emphasis>
        </para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_38b5f115-9175-4613-bf14-6e4faa75bf7a">TLS</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_fdbf0f39-0547-465c-b574-eaddcaef4732">Manual</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0fb50633-0414-49b5-9001-3e205192c82d">Basic</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_58aaf314-09ae-4176-93e1-40b89f730530">Manual</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_ad1eb1d8-3c3c-43f1-9286-24a26bbb11bb">Anonymous</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_efdc6874-6d6d-468c-861d-a490e4d5311c">Manual</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b1e74a65-97c4-4401-a5ee-6b20b6b516d1">
          <emphasis role="bold">Create Config</emphasis>
        </para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1c5741b2-a565-47f0-babd-c599497873b0">TLS</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_64cce470-4b94-4513-bdb7-972592fa6991">Manual</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_55c7a159-b03b-41cd-b272-5792d54a2a88">Basic</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0234c950-355a-46a4-af79-0bfb5a792a7d">Manual</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_89674b3e-b276-4d91-a91a-3ddffb0d44ec">Anonymous</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_abb81268-ebcf-476f-860b-b0ae01702397">Manual</para>
      </td>
    </tr>
  </tbody>
  </table>
  <variablelist>
<varlistentry>
<term>TLS</term>
<listitem>
<para xml:id="para_ecbe2478-8052-4e94-8831-103fd19159dd">This pattern provides SSL/TLS authentication and encryption between client and server. It requires additional setup during installation because the TLS certificate information needs to be installed onto the client machines and server. Once the certificates are installed the clients may then perform full updating operations.</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>TLS-Manual</term>
<listitem>
<para xml:id="para_4ec5598a-30f8-4431-b24f-9eeb06e8c573">This pattern provides SSL/TLS controls for read access to information and require manual intervention to perform update and creation functions.</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>Basic</term>
<listitem>
<para xml:id="para_8ce01b4d-1613-4ca3-8569-71d3edaecf34">This pattern utilizes the LDAP basic security to gain access to the LDAP database. It requires the installation of a password during client setup. It does not provide encryption protection. Once the password is installed, the client can then perform updates.</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>Basic-Manual</term>
<listitem>
<para xml:id="para_ca72834a-d808-438f-af86-bed5b1c07ada">This pattern utilizes basic security protection for read access to the configuration information and requires manual intervention to perform update and creation functions.</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>Anonymous</term>
<listitem>
<para xml:id="para_f486a1e0-92df-4ca1-9602-7d82e7eb362c">This pattern permits full read/update access to all machines on the network.</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>Anonymous-Manual</term>
<listitem>
<para xml:id="para_99826d4e-3f33-4ce7-ba05-c69fb04c8f0e">This pattern permits full read access to all machines on the network, but requires manual intervention to perform update and creation.</para>
</listitem>
</varlistentry>
  </variablelist>
  <para xml:id="para_38a6dcee-bf3a-4d34-bddb-f690e5bf8f59">A client or server implementation may be capable of being configured to support multiple patterns. This should be documented in the conformance claim. The specific configuration in use at a specific site can then be determined at installation time.</para>
  </section>
</section>
<section label="H.1.6" status="3" xml:id="sect_H.1.6">
    <title>Implementation Considerations (Informative)</title>
  
  <para xml:id="para_40e8fa3f-3943-4e89-a070-4ced3ca151c1">The LDAP database can be used as a documentation tool. Documenting the configuration for both managed and legacy machines makes upgrading easier and reduces the error rate for manually configured legacy equipment.</para>
  <para xml:id="para_c726f14f-3c3a-4ed8-b578-fcfd053bed26">There are various possible implementation strategies for clients performing lookups within the LDAP database. For example, before initiating a DICOM association to a specific AE, a client implementation could either:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_2cab6280-3f4f-4e54-bfac-9ee5d6781c60">Query the LDAP database to obtain hostname and port for the specific AE Title immediately prior to initiating a DICOM association.</para>
</listitem>
<listitem>
<para xml:id="para_cf17dbdc-57cd-483f-a99c-30c91988b3ff">Maintain a local cache of AE Title, hostname and port information and only query the LDAP database if the specific AE Title is not found in the local cache.</para>
</listitem>
</orderedlist>
  <para xml:id="para_85e5698c-2a13-42be-acae-4aba84da0e16">The advantages of maintaining a local cache include performance (by avoiding frequent lookups) and reliability (should the LDAP server be temporarily unavailable). The disadvantage of a cache is that it can become outdated over time. Client implementations should provide appropriate mechanisms to purge locally cached information.</para>
  <para xml:id="para_43a205cd-0a7b-4545-9128-715006f311a8">Client caches may cause confusion during updates. Manual steps may be needed to trigger immediate updates. LDAP database replication also may introduce delays and inconsistencies. Database replication may also require manual intervention to force updates to occur immediately.</para>
  <para xml:id="para_f3c63023-b1bc-4e1e-95c0-029effabdb7a">One strategy to reduce client cache problems is to re-acquire new DNS and LDAP information after any network association information. Often the first symptom of stale cache information is association failures due to the use of obsolete configuration information.</para>
  <para xml:id="para_93d6cd70-3e16-4f0c-a310-c2237747c788">Some LDAP servers do not support a "modify DN" operation. For example, in the case of renaming a device on such a server, a tree copy operation may be needed to create a new object tree using the new name, followed by removal of the old object tree. After such a rename the device may need to search using other attributes when finding its own configuration information, e.g., the device serial number.</para>
  </section>
<section label="H.1.7" status="3" xml:id="sect_H.1.7">
    <title>Conformance</title>
  
  <para xml:id="para_59b196ad-060d-43f6-b195-82ec7cf8e6c0">The Conformance Statement for an LDAP Client or LDAP Server implementation shall specify the security pattern(s) that it supports.</para>
  </section>
</section>
<section label="H.2" status="2" xml:id="sect_H.2">
    <title>DNS Service Discovery</title>
  
  <section label="H.2.1" status="3" xml:id="sect_H.2.1">
    <title>Scope</title>
  
  <para xml:id="para_eb59053e-d585-4813-9589-a265a7e20712">Service discovery mechanisms provide a means for devices to announce their presence and seek information about the existence of other services on the network. Many of these mechanisms are DNS-based.</para>
  <para xml:id="para_831b841c-cd6c-4cdd-ab6e-0abff7e9d0f9">The exact use of such protocols as DNS Service Discovery (DNS-SD), Multi-cast DNS (mDNS) and DNS Dynamic Updates is defined in RFCs referenced by DICOM. This section standardizes the name to be used in DNS SRV records for such purposes, and the DNS TXT records that encode accompanying parameters.</para>
  <para xml:id="para_7f29c0ba-4c52-4e19-b334-1ca98aa95d08">Security issues associated with self-discovery are out of scope. See <xref linkend="sect_F.1.1.4" xrefstyle="select: label"/> for the informative discussion on DNS Security issues.</para>
  </section>
<section label="H.2.2" status="3" xml:id="sect_H.2.2">
    <title>Use Case Roles</title>
  
  <para xml:id="para_3c3fd7e7-c8b2-421f-b0fe-6292ff76d0a9">
  <figure label="H.2-1" pgwide="1" xml:id="figure_H.2-1">
    <title>Find DICOM Service</title>
    <mediaobject>
      <imageobject>
        <imagedata fileref="figures/PS3.15_H.2-1.svg"/>
        <!--<imagedata fileref="part15_fromword_files/image034.png"/>-->
      </imageobject>
    </mediaobject>
  </figure>
</para>
  <variablelist>
    <varlistentry>
<term>DNS Server</term>
<listitem>
<para xml:id="para_605c7c2b-5b8b-4357-9a18-dba02b5af787">Provides list of DICOM Association Acceptors</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>DNS Client</term>
<listitem>
<para xml:id="para_7f5d1d6a-625c-4343-abe7-920eed1a9d08">Requests list of DICOM Association Acceptors</para>
</listitem>
</varlistentry>
  </variablelist>
</section>
            <section label="H.2.3" status="3" xml:id="sect_H.2.3">
                <title>Referenced Standards</title>

                <para xml:id="para_34b6e767-ea16-4db3-af31-8a5c2cd1aabf">
                    <xref linkend="biblio_RFC_2136"/> DNS Dynamic Updates</para>
                <para xml:id="para_a620f0d5-02c5-4543-a057-7299af7b010c">
                    <xref linkend="biblio_RFC_2181"/> Clarifications to the DNS Specification</para>
                <para xml:id="para_08fa6e11-8bc2-4bbc-a788-29ce47262885">
                    <xref linkend="biblio_RFC_2219"/> Use of DNS Aliases for Network Services</para>
                <para xml:id="para_a3bd3b28-8e2c-4918-bfbd-da44226ec0f5">
                    <xref linkend="biblio_RFC_2782"/> A DNS RR for specifying the location of services (DNS SRV)</para>
                <para xml:id="para_4176f1ce-179f-4920-9df5-317b294f09be">
                    <xref linkend="biblio_RFC_6762"/> Multicast DNS</para>
                <para xml:id="para_1bc7caba-1c2b-4509-87bc-3ca1cdbaed1a">
                    <xref linkend="biblio_RFC_6763"/> DNS-Based Service Discovery</para>
                <para xml:id="para_186d9a1c-3717-47a8-8c38-f4b24457d619">
                    <xref linkend="biblio_RFC_8553"/> DNS AttrLeaf Changes</para>
                <para xml:id="para_0ed85e47-1f58-4f0c-83bf-5a330a6f521f">
                    <xref linkend="biblio_DNSSD"/> DNS Self-Discovery </para>

                <para xml:id="para_d60d1240-2101-48da-92a3-5c5f26e02198">The name to be used in the DNS SRV to advertise DICOM Association Acceptors, regardless of the SOP Class(es) supported, shall be</para>
                <itemizedlist>
                    <listitem>
                        <para xml:id="para_74a3bc73-aac7-4631-a50b-8fd245684c5b">"dicom" for unsecured DICOM communication</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_ed2638cd-33c9-4f4e-8fd1-141bbe7a807e">"dicom-tls" for the Basic TLS Secure Transport Connection Profile</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_fec61f4e-c092-42c5-87bd-4cf8328a0094">"dicom-iscl" for ISCL Transport Connection Profile</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_872fd0d7-d7bc-4d15-bbf1-02c27f69972a">"dicomweb" for DICOM web services over unsecured http</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_6ac6baf9-64b0-4088-9195-a6abd8fa1735">"dicomweb-tls" for DICOM web services over https</para>
                    </listitem>
                </itemizedlist>
                <note>
                    <para xml:id="para_d82058b3-3695-44d5-9d2d-1e97e19b6515">These choices are consistent with the names registered with IANA to define the mapping of IP ports to services, which is conventional for this usage. The choice "dicom" is used rather than the "acr-nema" alternative for clarity. There is no implied port choice by the usage in the DNS SRV Service Type, since the port is explicitly conveyed.</para>
                </note>
                <para xml:id="para_f35e3cf8-a6e5-4bc1-ba4e-fc09056ea256">The DNS TXT record may contain the following parameters:</para>
                <itemizedlist>
                    <listitem>
                        <para xml:id="para_feca3b53-c009-4142-8d29-a1ef84cbc276">AET= <emphasis role="italic">&lt;application entity title&gt;</emphasis>, where the value <emphasis role="italic">&lt;application entity title&gt;</emphasis>is to be used as the Called Application Entity Title when initiating Associations to the device</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_ed187a3b-81d6-4444-aa22-63a2e2303bf0">PrimaryDeviceType= <emphasis role="italic">&lt;primary device type&gt;</emphasis>, where the value <emphasis role="italic">&lt;primary device type&gt;</emphasis>is as defined <xref linkend="table_H.1-2" xrefstyle="select: label"/> Attributes of Device Object</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_eafdda71-3d03-479c-baf6-70de6e10654f">DICOMWebPath= <emphasis role="italic">&lt;service&gt;</emphasis>, where the value <emphasis role="italic">&lt;service&gt;</emphasis> is the <emphasis role="italic">path</emphasis> component of the DICOM Web Service root as defined in <olink targetdoc="PS3.18" targetptr="PS3.18" xrefstyle="select: labelnumber"/>
                        </para>
                    </listitem>
                </itemizedlist>
                <para xml:id="para_6239b305-7c22-4957-ba47-ef5364e90b0c">In the absence of a DNS TXT record, or the AET parameter of the DNS TXT record, then the Instance Name preceding the Service Type in the DNS SRV record used for DICOM service discovery shall be the AET.</para>
                <note>
                    <para xml:id="para_f26c9b62-fec1-4076-b790-6980bb11c58a">Further parameters are not specified, for example to indicate the SOP Classes supported or other information, since the size of DNS records encoded as UDP datagrams is strictly limited, and furthermore, the envisaged multicast usage encourages the exchange of the minimal information necessary. The existing DICOM association negotiation mechanism can be used to explore the SOP Classes offered once the IP address, port number and AET are known. The primary device type is supplied because it is useful to indicate to users the type of device, which is not conveyed during association establishment.</para>
                </note>
            </section>
  <section label="H.2.4" status="3" xml:id="sect_H.2.4">
    <title>Examples</title>
    <para xml:id="para_f20e3ede-8d69-4ea5-b731-a8b4e215fb04">Example SRV record:</para>
    <itemizedlist>
      <listitem>
        <para xml:id="para_e4eed3ab-e7ee-4936-abf5-607cb7154e68">_dicomweb-tls._tcp. examplehospital.org 86400 IN SRV 10 60 443 dicomweb.examplehospital.org.</para>
      </listitem>
    </itemizedlist>
    <para xml:id="para_018d57eb-13ca-4e2d-ad0c-b6a03b478574">Example TXT record:</para>
    <itemizedlist>
      <listitem>
        <para xml:id="para_6b688cc4-27af-45eb-abb0-b05d2cfbd88e">dicomweb.examplehospital.org   IN   TXT   "DICOMWebPath=apps/dicom-rs"</para>
      </listitem>
    </itemizedlist>
    <para xml:id="para_29936fa1-6814-40e7-8edb-b6085b55e13a">The above examples would combine to define a DICOM web service root of:</para>
    <itemizedlist>
      <listitem>
        <para xml:id="para_d883e9ff-83a5-4b20-9804-80b0d874218a">"https://dicomweb.examplehospital.org:443/apps/dicom-rs"</para>
      </listitem>
    </itemizedlist>
  </section>
    <section label="H.2.5" status="3" xml:id="sect_H.2.5">
        <title>Conformance</title>
        <para xml:id="para_9afc5d9c-0c0b-40f1-a586-d054d5c092ca">An implementation that supports this profile shall state in its Conformance Statement whether it supports reading (DNS Client) or writing DNS (DNS Server) records.</para>
        <para xml:id="para_8ae48d53-3d2d-4414-9cad-f136f6c907a5">An implementation that supports this profile shall state in its Conformance Statement whether it supports DNSSEC <xref linkend="biblio_RFC_4033"/> <xref linkend="biblio_RFC_4034"/> <xref linkend="biblio_RFC_4035"/> for the interactions described in this profile, in which case either the options supported shall be stated or a reference provided to the DNSSEC support for this product.</para>
    </section>
</section>
</chapter>
</book>