<book xmlns="http://docbook.org/ns/docbook" xmlns:xhtml="http://www.w3.org/1999/xhtml" xmlns:xl="http://www.w3.org/1999/xlink" label="PS3.7" version="5.0" xml:id="PS3.7">
  <title>PS3.7</title>
  <subtitle>DICOM PS3.7 2026b - Message Exchange</subtitle>
  <info>
    <author>
      <orgname>DICOM Standards Committee</orgname>
    </author>
    <copyright>
      <year>2026</year>
      <holder>NEMA</holder>
    </copyright>
      <legalnotice>
          <para xml:id="para_0e39b077-b88b-4481-9131-2c29c229ecc3">A DICOM® publication</para>
      </legalnotice>
  </info>
  <chapter label="" status="1" xml:id="chapter_Notice">
    <title>Notice and Disclaimer</title>
    <para xml:id="para_ee95ce72-318a-4065-9965-0252fb976756">The information in this publication was considered technically sound by the consensus of
      persons engaged in the development and approval of the document at the time it was developed.
      Consensus does not necessarily mean that there is unanimous agreement among every person
      participating in the development of this document.</para>
    <para xml:id="para_70daf9ea-24f3-4c23-80aa-dcda1653b060">NEMA standards and guideline publications, of which the document contained herein is one,
      are developed through a voluntary consensus standards development process. This process brings
      together volunteers and/or seeks out the views of persons who have an interest in the topic
      covered by this publication. While NEMA administers the process and establishes rules to
      promote fairness in the development of consensus, it does not write the document and it does
      not independently test, evaluate, or verify the accuracy or completeness of any information or
      the soundness of any judgments contained in its standards and guideline publications.</para>
    <para xml:id="para_a67ebf04-eb6b-4bc2-9923-b116fac25cb0">NEMA disclaims liability for any personal injury, property, or other damages of any nature
      whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly
      resulting from the publication, use of, application, or reliance on this document. NEMA
      disclaims and makes no guaranty or warranty, expressed or implied, as to the accuracy or
      completeness of any information published herein, and disclaims and makes no warranty that the
      information in this document will fulfill any of your particular purposes or needs. NEMA does
      not undertake to guarantee the performance of any individual manufacturer or seller's products
      or services by virtue of this standard or guide.</para>
    <para xml:id="para_3cee07b2-05f3-4092-a66d-934cecb5fc9e">In publishing and making this document available, NEMA is not undertaking to render
      professional or other services for or on behalf of any person or entity, nor is NEMA
      undertaking to perform any duty owed by any person or entity to someone else. Anyone using
      this document should rely on his or her own independent judgment or, as appropriate, seek the
      advice of a competent professional in determining the exercise of reasonable care in any given
      circumstances. Information and other standards on the topic covered by this publication may be
      available from other sources, which the user may wish to consult for additional views or
      information not covered by this publication.</para>
    <para xml:id="para_6fff4030-d612-453d-9fb3-bf66ec11599f">NEMA has no power, nor does it undertake to police or enforce compliance with the contents
      of this document. NEMA does not certify, test, or inspect products, designs, or installations
      for safety or health purposes. Any certification or other statement of compliance with any
      health or safety-related information in this document shall not be attributable to NEMA and is
      solely the responsibility of the certifier or maker of the statement.</para>
  </chapter>
  <chapter label="" status="1" xml:id="chapter_Foreword">
    <title>Foreword</title>
    <para xml:id="para_8a77ef2c-fa98-4acb-aebb-abf2cdc38f94">This DICOM Standard was developed according to the procedures of the DICOM Standards Committee.</para>
    <para xml:id="para_7eee8c6b-a8c7-48e3-846a-f7eff9f48b79">The DICOM Standard is structured as a multi-part document using the guidelines established in <xref linkend="biblio_ISODirectives2"/>.</para>
    <para xml:id="para_e5d14809-cf0b-4a0f-a292-746843498678">DICOM® is the registered trademark of the National Electrical Manufacturers Association for its standards publications relating to digital communications of medical information, all rights reserved.</para>
    <para xml:id="para_836a4e2b-f5ac-47c9-b589-9a1888a4e719">HL7® and CDA® are the registered trademarks of Health Level Seven International, all rights reserved.</para>
    <para xml:id="para_7de7b970-2fbc-43f0-836f-8e77dc1ea3e1">SNOMED®, SNOMED Clinical Terms®, SNOMED CT® are the registered trademarks of the International Health Terminology Standards Development <foreignphrase xml:lang="en-GB">Organisation</foreignphrase> (IHTSDO), all rights reserved.</para>
    <para xml:id="para_e48e619a-16fd-4e3a-ba06-08042871a0ba">LOINC® is the registered trademark of Regenstrief Institute, Inc, all rights reserved.</para>
  </chapter>
  <chapter label="1" status="1" xml:id="chapter_1">
    <title>Scope and Field of Application</title>
  <para xml:id="para_74fed3f7-552e-4542-ac8c-c87ddc075815">This Part of the DICOM Standard specifies the DICOM Message Service Element (DIMSE). The DIMSE defines an Application Service Element (both the service and protocol) used by peer DICOM Application Entities for the purpose of exchanging medical images and related information.</para>
  <para xml:id="para_fc97dd66-473b-46c2-a594-0cf24914e078">The DIMSE provides its services by relying on the DIMSE protocol. The DIMSE protocol defines the encoding rules necessary to construct Messages. A Message is composed of a Command Set (defined in this Part of the DICOM Standard) followed by a conditional Data Set (defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>).</para>
  <para xml:id="para_6703a7d3-0abe-4776-90ec-6f80164b40cb">This Part specifies:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_38963d05-73c1-4e1f-bfdf-629ab9d06ad5">a set of service primitives provided by the DIMSE Application Service Element</para>
</listitem>
  <listitem>
<para xml:id="para_8d25257f-3182-4f78-873f-c46d570d880c">the parameters that are passed in each service primitive</para>
</listitem>
  <listitem>
<para xml:id="para_f860e096-01aa-4908-b9bd-fb8c68e6037e">any necessary information for the semantic description of each service primitive</para>
</listitem>
  <listitem>
<para xml:id="para_7af0b202-a1c1-4c6b-8996-de481bc2541e">the procedures applicable to the service primitives</para>
</listitem>
  <listitem>
<para xml:id="para_41e8e502-da69-4794-aa88-29c17b4996cb">the Abstract Syntax of the DICOM composite and normalized command protocol and the associated encoding rules to be applied</para>
</listitem>
  <listitem>
<para xml:id="para_feeea80f-c11a-42e1-ab58-dfacf1d9eb88">procedures for the correct interpretation of protocol control information</para>
</listitem>
  <listitem>
<para xml:id="para_ca2a9a4d-7dcd-4420-b0d7-2e5118d5168b">the conformance requirements to be met by implementation of this Part of the Standard</para>
</listitem>
  <listitem>
<para xml:id="para_2279c1f4-2eea-4df9-a2ae-c032b15f1bbb">the Application Context required for DICOM Application Entities</para>
</listitem>
  <listitem>
<para xml:id="para_61b7f792-851e-4fb7-977d-a408750a120e">the Association requirements of DICOM Application Entities</para>
</listitem>
  <listitem>
<para xml:id="para_22b41839-a462-46c7-a70e-0323e9d26a07">the Application Association Information for DICOM Application Entities</para>
</listitem>
</itemizedlist>
  <para xml:id="para_1c4f1279-93dc-4fa5-af41-785d2db80d0f">This Part is related to other parts of the DICOM Standard in that:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_244fed27-b905-4d5a-babe-abb19185bba0">
<olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>, Information Object Definitions, specifies the set of Information Object Definitions to which the services defined in this Part may be applied</para>
</listitem>
  <listitem>
<para xml:id="para_8f610fbf-9ebe-4a85-86b8-e9d3c2512dfb">
<olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>, Data Structure and Encoding, addresses the encoding rules necessary to construct a conditional Data Set that is conveyed in a Message as specified in this Part</para>
</listitem>
  <listitem>
<para xml:id="para_53af4d78-bf11-4dd9-9645-24a9a3b65852">This Part defines the protocols and services required to accomplish the Service Classes described in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>
</para>
</listitem>
</itemizedlist>
  </chapter>
<chapter label="2" status="1" xml:id="chapter_2">
    <title>Normative References</title>
  
  <para xml:id="para_de530570-903f-4e31-9c12-e214cc763c37">The following Standards contain provisions that, through reference in this text, constitute provisions of this Standard. At the time of publication, the editions indicated were valid. All Standards are subject to revision, and parties to agreements based on this Standard are encouraged to investigate the possibilities of applying the most recent editions of the Standards indicated below.</para>
  <bibliography>
    <biblioentry xml:id="biblio_ISODirectives2">
      <abbrev>ISO/IEC Directives, Part 2</abbrev>
      <author>
        <orgname>ISO/IEC</orgname>
      </author>
      <date>2021</date>
      <edition>9.0</edition>
      <title>Rules for the structure and drafting of International Standards</title>
      <bibliosource>
        <link xl:href="http://www.iso.org/sites/directives/current/part2/index.xhtml"/>
      </bibliosource>
    </biblioentry>
      <biblioentry xml:id="biblio_ISO7498-1">
          <abbrev>ISO 7498-1</abbrev>
          <author>
              <orgname>ISO</orgname>
          </author>
          <date>1994</date>
          <title>Information Processing Systems - Open Systems Interconnection - Basic Reference Model</title>
      </biblioentry>
      <biblioentry xml:id="biblio_ISO8509">
          <abbrev>ISO/TR 8509</abbrev>
          <author>
              <orgname>ISO</orgname>
          </author>
          <title>Information Processing Systems - Open Systems Interconnection - Service Conventions</title>
          <releaseinfo>
              <remark>ISO/TR 8509 has been withdrawn. See ISO/IEC 2382-26:1993 Information technology - Vocabulary - Part 26: Open systems interconnection</remark>
          </releaseinfo>
      </biblioentry>
      <biblioentry xml:id="biblio_ISO8649">
          <abbrev>ISO 8649</abbrev>
          <author>
              <orgname>ISO</orgname>
          </author>
          <date>1988</date>
          <title>Information processing systems - Open Systems Interconnection - Service definition for the Association Control Service Element (ACSE)</title>
      </biblioentry>
      <biblioentry xml:id="biblio_ISO8822">
          <abbrev>ISO 8822</abbrev>
          <author>
              <orgname>ISO</orgname>
          </author>
          <date>1988</date>
          <title>Information processing systems - Open Systems Interconnection - Connection oriented presentation service definition</title>
      </biblioentry>
      <biblioentry xml:id="biblio_ISOIEC9595">
          <abbrev>ISO/IEC 9595</abbrev>
          <author>
              <orgname>ISO</orgname>
          </author>
          <date>1991</date>
          <title>Information processing systems - Open Systems Interconnection - Common Management Information Service Definition</title>
      </biblioentry>
      <biblioentry xml:id="biblio_ISOIEC9834-1">
          <abbrev>ISO/IEC 9834-1</abbrev>
          <author>
              <orgname>ISO</orgname>
          </author>
          <date>2012</date>
          <title>Information processing systems - Open Systems Interconnection - Procedures for the operation of OSI Registration Authorities: General procedures and top arcs of the ASN.1 Object Identifier tree</title>
      </biblioentry>
      <biblioentry xml:id="biblio_RFC_1510">
          <abbrev>RFC1510</abbrev>
          <author>
              <orgname>IETF</orgname>
          </author>
          <date>September 1993</date>
          <title>The Kerberos Network Authentication Service (V5)</title>
          <bibliosource>
              <link xl:href="http://tools.ietf.org/html/rfc1510"/>
          </bibliosource>
      </biblioentry>
      <biblioentry xml:id="biblio_RFC_2289">
          <abbrev>RFC2289</abbrev>
          <author>
              <orgname>IETF</orgname>
          </author>
          <date>February 1998</date>
          <title>A One-Time Password System</title>
          <bibliosource>
              <link xl:href="http://tools.ietf.org/html/rfc2289"/>
          </bibliosource>
      </biblioentry>
      <biblioentry xml:id="biblio_RFC_6750">
          <abbrev>RFC6750</abbrev>
          <author>
              <orgname>IETF</orgname>
          </author>
          <date>October 2012</date>
          <title>The OAuth 2.0 Authorization Framework: Bearer Token Usage</title>
          <bibliosource>
              <link xl:href="http://tools.ietf.org/html/rfc6750"/>
          </bibliosource>
      </biblioentry>
      <biblioentry xml:id="biblio_RFC_7519">
          <abbrev>RFC7519</abbrev>
          <author>
              <orgname>IETF</orgname>
          </author>
          <date>May 2015</date>
          <title>JSON Web Token (JWT)</title>
          <bibliosource>
              <link xl:href="http://tools.ietf.org/html/rfc7519"/>
          </bibliosource>
      </biblioentry>
      <biblioentry xml:id="biblio_RFC_7662">
          <abbrev>RFC7662</abbrev>
          <author>
              <orgname>IETF</orgname>
          </author>
          <date>October 2015</date>
          <title>OAuth 2.0 Token Introspection</title>
          <bibliosource>
              <link xl:href="http://tools.ietf.org/html/rfc7662"/>
          </bibliosource>
      </biblioentry>
      <biblioentry xml:id="biblio_OASIS_SAML_V2">
          <abbrev>SAML</abbrev>
          <author>
              <orgname>OASIS</orgname>
          </author>
          <date>15 March 2005</date>
          <title>SAML Assertions and Protocols for the OASIS Security Assertion Markup Language (SAML) V2.0 OASIS Standard</title>
          <bibliosource>
              <link xl:href="https://docs.oasis-open.org/security/saml/v2.0/saml-core-2.0-os.pdf"/>
          </bibliosource>
      </biblioentry>
  </bibliography>
</chapter>
    <chapter label="3" status="1" xml:id="chapter_3">
        <title>Definitions</title>
        <para xml:id="para_4ea492c9-0785-4902-b433-80bd1297f19d">For the purposes of this Standard the following definitions apply.</para>
        <glossary>
            <glossdiv label="3.1" status="2" xml:id="sect_3.1">
                <title>Reference Model Definitions</title>
                <para xml:id="para_2a040a14-5443-47a9-b6f7-95992936b9a5">This Part of the Standard is based on the concepts developed in <xref linkend="biblio_ISO7498-1"/> and makes use of the following terms defined in it:</para>
                <glossentry xml:id="glossentry_ApplicationEntity" xreflabel="Application Entity">
                    <glossterm>ApplicationEntity</glossterm>
                    <glossdef>
                        <para xml:id="para_4d466cc9-244c-48de-af2b-9bb2984d0a9c">See <xref linkend="biblio_ISO7498-1"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_ApplicationProcess" xreflabel="Application Process">
                    <glossterm>Application Process</glossterm>
                    <glossdef>
                        <para xml:id="para_f9c5cb06-d72f-4bca-8fde-c0b9b2fdf320">See <xref linkend="biblio_ISO7498-1"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_Protocol" xreflabel="Protocol">
                    <glossterm>Protocol</glossterm>
                    <glossdef>
                        <para xml:id="para_6fdf6ab7-57bf-4012-ab47-12bbdc0a1e59">See <xref linkend="biblio_ISO7498-1"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_ProtocolDataUnit" xreflabel="Protocol Data Unit">
                    <glossterm>Protocol Data Unit</glossterm>
                    <glossdef>
                        <para xml:id="para_ac8d4f62-489e-43ef-9e19-8bbcd044f102">See <xref linkend="biblio_ISO7498-1"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_Service" xreflabel="Service">
                    <glossterm>Service</glossterm>
                    <glossdef>
                        <para xml:id="para_6c72fbb6-d81d-44b7-81d2-b3b067b54971">See <xref linkend="biblio_ISO7498-1"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_TransferSyntax" xreflabel="Transfer Syntax">
                    <glossterm>Transfer Syntax</glossterm>
                    <glossdef>
                        <para xml:id="para_34906243-9af5-4d4a-bf25-921a15cc6fe2">See <xref linkend="biblio_ISO7498-1"/>.</para>
                    </glossdef>
                </glossentry>
            </glossdiv>
            <glossdiv label="3.2" status="2" xml:id="sect_3.2">
                <title>Service Conventions Definitions</title>
                <para xml:id="para_707e45a7-1bfa-4b48-a91e-9372d01c976e">This Part of the Standard makes use of the following terms defined in <xref linkend="biblio_ISO8509"/>:</para>
                <glossentry xml:id="glossentry_ServiceProvider" xreflabel="Service Provider">
                    <glossterm>Service Provider</glossterm>
                    <glossdef>
                        <para xml:id="para_5ca98cca-2c6c-4a61-aee5-32b95578d09a">See <xref linkend="biblio_ISO8509"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_ServiceUser" xreflabel="Service User">
                    <glossterm>Service User</glossterm>
                    <glossdef>
                        <para xml:id="para_28d7ea77-addb-4a4d-8de9-842754e2b1fa">See <xref linkend="biblio_ISO8509"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_ConfirmedService" xreflabel="Confirmed Service">
                    <glossterm>Confirmed Service</glossterm>
                    <glossdef>
                        <para xml:id="para_b978b81b-5033-46e2-b563-3f65f9865f97">See <xref linkend="biblio_ISO8509"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_NonConfirmedService" xreflabel="Non-confirmed Service">
                    <glossterm>Non-confirmed Service</glossterm>
                    <glossdef>
                        <para xml:id="para_fca584ed-5364-4033-adff-bd7819c530de">See <xref linkend="biblio_ISO8509"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_Primitive" xreflabel="Primitive">
                    <glossterm>Primitive</glossterm>
                    <glossdef>
                        <para xml:id="para_c0d3f378-d0fd-4390-b58f-2d9c5750814b">See <xref linkend="biblio_ISO8509"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_RequestPrimitive" xreflabel="Request (Primitive)">
                    <glossterm>Request (Primitive)</glossterm>
                    <glossdef>
                        <para xml:id="para_ae6f7b3c-85f6-4ba8-b162-4c44f6b8d0f8">See <xref linkend="biblio_ISO8509"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_IndicationPrimitive" xreflabel="Indication (Primitive)">
                    <glossterm>Indication (Primitive)</glossterm>
                    <glossdef>
                        <para xml:id="para_015c8578-c037-4320-baee-0db9b7d01394">See <xref linkend="biblio_ISO8509"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_ResponsePrimitive" xreflabel="Response (Primitive)">
                    <glossterm>Response (Primitive)</glossterm>
                    <glossdef>
                        <para xml:id="para_9d973305-82ad-43d9-b675-26c22ad359d9">See <xref linkend="biblio_ISO8509"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_ConfirmPrimitive" xreflabel="Confirm (Primitive)">
                    <glossterm>Confirm (Primitive)</glossterm>
                    <glossdef>
                        <para xml:id="para_15d662e6-8229-480c-a62f-ef85825e7ec6">See <xref linkend="biblio_ISO8509"/>.</para>
                    </glossdef>
                </glossentry>
            </glossdiv>
            <glossdiv label="3.3" status="2" xml:id="sect_3.3">
                <title>Presentation Service Definitions</title>
                <para xml:id="para_bc785b16-8d69-4bfb-b59e-d010bb5d0b35">This Part of the Standard makes use of the following terms defined in <xref linkend="biblio_ISO8822"/>:</para>
                <glossentry xml:id="glossentry_AbstractSyntax" xreflabel="Abstract Syntax">
                    <glossterm>Abstract Syntax</glossterm>
                    <glossdef>
                        <para xml:id="para_6d85578e-d13f-4df4-bd6e-e1fbebfe48cc">See <xref linkend="biblio_ISO8822"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_AbstractSyntaxName" xreflabel="Abstract Syntax Name">
                    <glossterm>Abstract Syntax Name</glossterm>
                    <glossdef>
                        <para xml:id="para_13c3ff04-56f1-4b64-8f7a-02f505a17586">See <xref linkend="biblio_ISO8822"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_PresentationContext" xreflabel="Presentation Context">
                    <glossterm>Presentation Context</glossterm>
                    <glossdef>
                        <para xml:id="para_9a252d2f-2fce-404c-b81e-0b3ad8c492df">See <xref linkend="biblio_ISO8822"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_PresentationDataValue" xreflabel="Presentation Data Value">
                    <glossterm>Presentation Data Value</glossterm>
                    <glossdef>
                        <para xml:id="para_8c51bbbb-d6e0-48a4-bf6a-1189b7175c92">See <xref linkend="biblio_ISO8822"/>.</para>
                    </glossdef>
                </glossentry>
            </glossdiv>
            <glossdiv label="3.4" status="2" xml:id="sect_3.4">
                <title>ACSE Service Definitions</title>
                <para xml:id="para_3714ab81-d3aa-4905-88ca-ec01f141b7c2">This Part of the Standard makes use of the following terms defined in <xref linkend="biblio_ISO8649"/>:</para>
                <glossentry xml:id="glossentry_Association" xreflabel="Association or Application Association">
                    <glossterm>Association</glossterm>
                    <glossdef>
                        <para xml:id="para_371b7101-1933-4207-90a6-afd57f13c414">See <xref linkend="biblio_ISO8649"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_ApplicationContext" xreflabel="Application Context">
                    <glossterm>Application Context</glossterm>
                    <glossdef>
                        <para xml:id="para_c5b61fe5-eba6-43ee-9cd5-103931370373">See <xref linkend="biblio_ISO8649"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_AssociationControlServiceElement" xreflabel="Association Control Service Element (ACSE)">
                    <glossterm>Association Control Service Element</glossterm>
                    <acronym>ACSE</acronym>
                    <glossdef>
                        <para xml:id="para_c2154f7c-b2ef-472a-86a2-924e3e0dd42d">See <xref linkend="biblio_ISO8649"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_AssociationInitiator" xreflabel="Association Initiator">
                    <glossterm>Association Initiator</glossterm>
                    <glossdef>
                        <para xml:id="para_a814cde1-5fbe-4469-b5f4-3fb1978cc7c2">See <xref linkend="biblio_ISO8649"/>.</para>
                    </glossdef>
                </glossentry>
            </glossdiv>
            <glossdiv label="3.5" status="2" xml:id="sect_3.5">
                <title>CMIS Service Definitions</title>
                <para xml:id="para_95777557-f4a5-44ca-8feb-234da086f127">This Part of the Standard makes use of the following terms defined in <xref linkend="biblio_ISOIEC9595"/>:</para>
                <glossentry xml:id="glossentry_FunctionalUnit" xreflabel="Functional Unit">
                    <glossterm>Functional Unit</glossterm>
                    <glossdef>
                        <para xml:id="para_d536804a-21ef-489c-a058-f475dca66482">See <xref linkend="biblio_ISOIEC9595"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_KernelFunctionalUnit" xreflabel="Kernel Functional Unit">
                    <glossterm>Kernel Functional Unit</glossterm>
                    <glossdef>
                        <para xml:id="para_783a7a63-dbf0-454d-b75e-f6675608897a">See <xref linkend="biblio_ISOIEC9595"/>.</para>
                    </glossdef>
                </glossentry>
            </glossdiv>
            <glossdiv label="3.6" status="2" xml:id="sect_3.6">
                <title>DICOM Introduction and Overview Definitions</title>

                <para xml:id="para_ed764051-6399-4653-a6cc-570200b9a820">This Part of the Standard makes use of the following terms defined in <olink targetdoc="PS3.1" targetptr="PS3.1" xrefstyle="select: labelnumber"/>:</para>

                <glossentry xml:id="glossentry_Attribute" xreflabel="Attribute">
                    <glossterm>Attribute</glossterm>
                    <glossdef>
                        <para xml:id="para_cf1c950d-06cd-4d93-bb87-08c5681125ee">
<olink targetdoc="PS3.1" targetptr="glossentry_Attribute" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_Command" xreflabel="Command">
                    <glossterm>Command</glossterm>
                    <glossdef>
                        <para xml:id="para_9c77bff1-6371-4397-9e6b-042b7ad6277e">
<olink targetdoc="PS3.1" targetptr="glossentry_Command" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_CommandStream" xreflabel="Command Stream">
                    <glossterm>Command Stream</glossterm>
                    <glossdef>
                        <para xml:id="para_d4e06e32-9ad2-42ee-b332-391260946139">
<olink targetdoc="PS3.1" targetptr="glossentry_CommandStream" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_DataStream" xreflabel="Data Stream">
                    <glossterm>Data Stream</glossterm>
                    <glossdef>
                        <para xml:id="para_e5fb897a-5aba-4911-997d-88a634a48dd5">
<olink targetdoc="PS3.1" targetptr="glossentry_DataStream" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_Message" xreflabel="Message">
                    <glossterm>Message</glossterm>
                    <glossdef>
                        <para xml:id="para_3f8985fa-4622-4005-bb67-05cb04ac49fb">
<olink targetdoc="PS3.1" targetptr="glossentry_Message" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_ServiceObjectPairClass" xreflabel="Service-Object Pair Class (SOP Class)">
                    <glossterm>Service-Object Pair Class</glossterm>
                    <acronym>SOP Class</acronym>
                    <glossdef>
                        <para xml:id="para_d817266c-7b16-4f0d-b445-1cc5ac471535">
<olink targetdoc="PS3.1" targetptr="glossentry_ServiceObjectPairClass" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>

            </glossdiv>
            <glossdiv label="3.7" status="2" xml:id="sect_3.7">
                <title>DICOM Upper Layer Service Definitions</title>
                <para xml:id="para_c4579257-7cda-44d3-8856-ec877fe046d4">This Part of the Standard makes use of the following terms defined in <olink targetdoc="PS3.8" targetptr="PS3.8" xrefstyle="select: labelnumber"/>:</para>
                <glossentry xml:id="glossentry_DICOMUpperLayerService" xreflabel="DICOM Upper Layer Service">
                    <glossterm>DICOM Upper Layer Service</glossterm>
                    <glossdef>
                        <para xml:id="para_cbe60261-1d0b-4e56-9976-7a46e9d64e64">
<olink targetdoc="PS3.8" targetptr="glossentry_DICOMUpperLayerService" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
            </glossdiv>
            <glossdiv label="3.8" status="2" xml:id="sect_3.8">
                <title>DICOM Service Class Definitions</title>
                <para xml:id="para_8e32933e-0329-4cc7-8db0-c6d1d49d1e87">This Part of the Standard makes use of the following terms defined in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>:</para>

                <glossentry xml:id="glossentry_ServiceClass" xreflabel="Service Class">
                    <glossterm>Service Class</glossterm>
                    <glossdef>
                        <para xml:id="para_8eaf6120-8fa9-462b-83ea-17ca2a1ae13f">
<olink targetdoc="PS3.4" targetptr="glossentry_ServiceClass" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_ServiceClassUser" xreflabel="Service Class User (SCU)">
                    <glossterm>Service Class User</glossterm>
                    <acronym>SCU</acronym>
                    <glossdef>
                        <para xml:id="para_64e262c0-ca44-4150-8964-65be3bb7602c">
<olink targetdoc="PS3.4" targetptr="glossentry_ServiceClassUser" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_ServiceClassProvider" xreflabel="Service Class Provider (SCP)">
                    <glossterm>Service Class Provider</glossterm>
                    <acronym>SCP</acronym>
                    <glossdef>
                        <para xml:id="para_d9b29f4d-7253-4a1c-be92-acbc14a9c36a">
<olink targetdoc="PS3.4" targetptr="glossentry_ServiceClassProvider" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_ServiceObjectPairInstance" xreflabel="Service-Object Pair Instance (SOP Instance)">
                    <glossterm>Service-Object Pair Instance</glossterm>
                    <acronym>SOP Instance</acronym>
                    <glossdef>
                        <para xml:id="para_2e7e6955-0206-4cc4-94c7-88f02c7fe363">
<olink targetdoc="PS3.4" targetptr="glossentry_ServiceObjectPairInstance" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_RelatedGeneralSOPClass" xreflabel="Related General SOP Class">
                    <glossterm>Related General SOP Class</glossterm>
                    <glossdef>
                        <para xml:id="para_f3a04b8a-0ff4-4fea-9dd2-a7df569f63b3">
<olink targetdoc="PS3.4" targetptr="glossentry_RelatedGeneralSOPClass" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
            </glossdiv>
            <glossdiv label="3.9" status="2" xml:id="sect_3.9">
                <title>DICOM Data Structures and Encoding Definitions</title>
                <para xml:id="para_eaf0b06f-d3b5-4a2b-84f5-6bfb59ef881d">This Part of the Standard makes use of the following terms defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>:</para>

                <glossentry xml:id="glossentry_DataElement" xreflabel="Data Element">
                    <glossterm>Data Element</glossterm>
                    <glossdef>
                        <para xml:id="para_df12b47e-bab1-4176-a433-2b31e9f92a91">
<olink targetdoc="PS3.5" targetptr="glossentry_DataElement" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_DataSet" xreflabel="Data Set">
                    <glossterm>Data Set</glossterm>
                    <glossdef>
                        <para xml:id="para_25abcf40-abfa-48dc-a604-66c17e1642a5">
<olink targetdoc="PS3.5" targetptr="glossentry_DataSet" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_DefaultCharacterRepertoire" xreflabel="Default Character Repertoire">
                    <glossterm>Default Character Repertoire</glossterm>
                    <glossdef>
                        <para xml:id="para_00da5aeb-8c31-4dba-be76-b5229c8d908c">
                            <olink targetdoc="PS3.5" targetptr="glossentry_DefaultCharacterRepertoire" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_ElementNumber" xreflabel="Element Number">
                    <glossterm>Element Number</glossterm>
                    <glossdef>
                        <para xml:id="para_bd8a253f-8f2b-456d-93bb-412a6a97c149">
                            <olink targetdoc="PS3.5" targetptr="glossentry_ElementNumber" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_GroupNumber" xreflabel="Group Number">
                    <glossterm>Group Number</glossterm>
                    <glossdef>
                        <para xml:id="para_756a0805-3a59-446a-84f0-131d48b316d1">
                            <olink targetdoc="PS3.5" targetptr="glossentry_GroupNumber" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_ImplicitVR" xreflabel="Implicit VR">
                    <glossterm>Implicit VR</glossterm>
                    <glossdef>
                        <para xml:id="para_16b9d027-45a3-4389-8d5a-b896536e0f5f">
                            <olink targetdoc="PS3.5" targetptr="glossentry_ImplicitVR" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_LittleEndian" xreflabel="Little Endian">
                    <glossterm>Little Endian</glossterm>
                    <glossdef>
                        <para xml:id="para_9cf1a424-0608-41c7-adf5-b29a44845492">
                            <olink targetdoc="PS3.5" targetptr="glossentry_LittleEndian" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_UniqueIdentifier" xreflabel="Unique Identifier (UID)">
                    <glossterm>Unique Identifier</glossterm>
                    <acronym>UID</acronym>
                    <glossdef>
                        <para xml:id="para_1093a8dd-2fe3-4fbc-aae7-763f86229b9a">
                            <olink targetdoc="PS3.8" targetptr="glossentry_UniqueIdentifier" xrefstyle="template:See %t in %o"/>.</para>
                    </glossdef>
                </glossentry>

            </glossdiv>
            <glossdiv label="3.10" status="2" xml:id="sect_3.10">
                <title>DICOM Message Exchange Definitions</title>
                <para xml:id="para_19ffe727-a194-448d-b5bd-5afa1e30dc5c">The following definitions are commonly used in this Part of the Standard:</para>
                <glossentry xml:id="glossentry_DICOMMessageServiceElement" xreflabel="DICOM Message Service Element (DIMSE)">
                    <glossterm>DICOM Message Service Element</glossterm>
                    <acronym>DIMSE</acronym>
                    <glossdef>
                        <para xml:id="para_12379fb6-e076-4f6f-9339-1311be1b195a">The particular Application Service Element defined in this Part of the DICOM Standard.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_DIMSECServices" xreflabel="DIMSE-C Services">
                    <glossterm>DIMSE-C Services</glossterm>
                    <glossdef>
                        <para xml:id="para_321391c2-f77b-4023-8dbe-bef5176d3059">A subset of the DIMSE services that supports operations on Composite SOP Instances related to composite Information Object Definitions with peer DIMSE Service Users.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_DIMSENServices" xreflabel="DIMSE-N Services">
                    <glossterm>DIMSE-N Services</glossterm>
                    <glossdef>
                        <para xml:id="para_1d5e49de-14a7-47de-b824-1f89f32ea55c">A subset of the DIMSE services that supports operations and notifications on Normalized SOP Instances related to Normalized Information Object Definitions with peer DIMSE Service Users.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_DIMSEServiceGroup" xreflabel="DIMSE Service Group (DSG)">
                    <glossterm>DIMSE Service Group</glossterm>
                    <acronym>DSG</acronym>
                    <glossdef>
                        <para xml:id="para_f5e3f25b-4276-41b3-9091-f62872551702">A specific set of one or more DIMSE Services that define the operations and/or notifications that can be performed on a data structure.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_DIMSEServiceProvider" xreflabel="DIMSE Service Provider">
                    <glossterm>DIMSE Service Provider</glossterm>
                    <glossdef>
                        <para xml:id="para_9f7017d7-16a8-474b-b533-f3045a20d1d0">An abstraction of the totality of those entities that provide DIMSE services to peer DIMSE Service Users.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_DIMSEServiceUser" xreflabel="DIMSE Service User">
                    <glossterm>DIMSE Service User</glossterm>
                    <glossdef>
                        <para xml:id="para_973f503a-f410-43ea-8f97-01d98d892feb">That part of an Application Entity that makes use of the DICOM Message Service Element.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_ExtendedNegotiation" xreflabel="Extended Negotiation">
                    <glossterm>Extended Negotiation</glossterm>
                    <glossdef>
                        <para xml:id="para_6d33b411-dcc6-4fcc-957c-743aee5a1408">Exchange of application information by peer DICOM AEs at Association establishment, defined by specific Service Class specifications.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_ImplementationClassUID" xreflabel="Implementation Class UID">
                    <glossterm>Implementation Class UID</glossterm>
                    <glossdef>
                        <para xml:id="para_12058e87-df96-4465-b739-06752418a0bc">The unique identifier of a specific class of implementation.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_InvokingDIMSEServiceUser" xreflabel="Invoking DIMSE Service User">
                    <glossterm>Invoking DIMSE Service User</glossterm>
                    <glossdef>
                        <para xml:id="para_9b685f6e-f3c0-4fe3-80c7-fa469239cb63">The DIMSE Service User that invokes a DIMSE operation or notification.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_PerformingDIMSEServiceUser" xreflabel="Performing DIMSE Service User">
                    <glossterm>Performing DIMSE Service User</glossterm>
                    <glossdef>
                        <para xml:id="para_22bc9d7f-6395-49ec-9138-5af07d323920">The DIMSE Service User that performs a DIMSE operation or notification invoked by a peer DIMSE Service User.</para>
                    </glossdef>
                </glossentry>
            </glossdiv>
        </glossary>
    </chapter>
<chapter label="4" status="1" xml:id="chapter_4">
    <title>Symbols and Abbreviations</title>
  
  <para xml:id="para_d666c369-a42e-474a-ae6d-e255f5783731">The following symbols and abbreviations are used in this Part of the Standard.</para>
  <variablelist>
  <varlistentry>
<term>ACR</term>
<listitem>
<para xml:id="para_e8c42beb-f1cc-4c96-8969-bf5a41ff412c">American College of Radiology</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>ACSE</term>
<listitem>
<para xml:id="para_f6067cce-a64f-468f-b61d-774e45760851">Association Control Service Element</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>ASCII</term>
<listitem>
<para xml:id="para_5ad22941-a44b-4e37-87fc-b5827ce0d2d3">American Standard Code for Information Interchange</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>AE</term>
<listitem>
<para xml:id="para_caadd91f-71ba-445c-8c5b-21e377c628a4">Application Entity</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>ANSI</term>
<listitem>
<para xml:id="para_b29730ac-18dc-44f1-a08c-79c534e639df">American National Standards Institute</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>CEN TC251</term>
<listitem>
<para xml:id="para_d43265fe-52bc-4ab8-a3d2-e7f320f00284">Comite Europeen de Normalisation - Technical Committee 251 - Medical Informatics</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>CMIS</term>
<listitem>
<para xml:id="para_3c6a1bfc-5e89-42d7-afac-4ff5cc7256a6">Common Management Information Service</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>CMISE</term>
<listitem>
<para xml:id="para_2bf7b07c-e8c6-4477-a5f8-b478fbc23817">Common Management Information Service Element</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>DICOM</term>
<listitem>
<para xml:id="para_d9a60e07-97d5-499f-8242-8acf0e22c710">Digital Imaging and Communications in Medicine</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>DIMSE</term>
<listitem>
<para xml:id="para_745511f7-509d-4f69-81d6-71112b566ceb">DICOM Message Service Element</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>DIMSE-C</term>
<listitem>
<para xml:id="para_5b801112-33de-4b5c-b707-b956eb22a00d">DICOM Message Service Element - Composite</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>DIMSE-N</term>
<listitem>
<para xml:id="para_eeb14ec7-283e-49e5-9def-10452deac347">DICOM Message Service Element - Normalized</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>HL7</term>
<listitem>
<para xml:id="para_f7031868-d75e-4fd4-814c-25feb319c891">Health Level 7</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>IEEE</term>
<listitem>
<para xml:id="para_21c81654-1f70-40e6-98e9-e9d928af8fc5">Institute of Electrical and Electronics Engineers</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>ISO</term>
<listitem>
<para xml:id="para_6b5b7a11-0b73-420c-9ee1-802f92a48780">International Standards Organization</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>JIRA</term>
<listitem>
<para xml:id="para_98869a2b-7863-4e6f-a376-6d5deb8c6efc">Japan Medical Imaging and Radiological Systems Industries Association</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>NEMA</term>
<listitem>
<para xml:id="para_5a081ca2-9794-43eb-b519-1a3079f1ecfd">National Electrical Manufacturers Association</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>OSI</term>
<listitem>
<para xml:id="para_6e1d0a99-24a4-49e6-bbca-f52b28fee240">Open Systems Interconnection</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>PDU</term>
<listitem>
<para xml:id="para_d20920f4-cb98-4f29-8da8-d0f8f89c92e2">Protocol Data Unit</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>PDV</term>
<listitem>
    <para xml:id="para_4e6c9796-0342-4afd-b2a3-34b137b64eef">Presentation Data Value</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>SOP</term>
<listitem>
<para xml:id="para_c30af054-3ed3-45f8-b3c0-4106620248ed">Service-Object Pair</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>TCP/IP</term>
<listitem>
<para xml:id="para_0a919737-328f-4171-9659-3d5f37e9414b">Transmission Control Protocol/Internet Protocol</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>VM</term>
<listitem>
<para xml:id="para_83a0d31c-b3b8-4dad-bc87-cab033fd20aa">Value Multiplicity</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>VR</term>
<listitem>
<para xml:id="para_a5ea74e0-f980-4281-900f-94c562818d24">Value Representation</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>UID</term>
<listitem>
<para xml:id="para_0116fe4a-a561-4dc7-82ba-50c83639e317">Unique Identifier</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>UL</term>
<listitem>
<para xml:id="para_d62d31a3-46d9-47ec-845d-b09cc4ff62a1">Upper Layer</para>
</listitem>
</varlistentry>
  </variablelist>
</chapter>
<chapter label="5" status="1" xml:id="chapter_5">
    <title>Conventions</title>
  
  <para xml:id="para_f97d881f-efbb-4961-b36d-022bcc2488f4">The following conventions are used for the service description tables shown in this Part of the Standard.</para>
  <variablelist>
  <varlistentry>
<term>(=)</term>
<listitem>
<para xml:id="para_3ef32782-146d-4b0b-8e88-5ad253c9e190">The value of the parameter is equal to the value of the parameter in the column to the left.</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>-</term>
<listitem>
<para xml:id="para_7d3012d4-f246-49a8-8dd9-3e435217a13b">Not applicable. The parameter shall not be present.</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>C</term>
<listitem>
<para xml:id="para_ded6bcf3-f582-4eaa-b28f-93ec20acb190">The parameter is conditional. The condition(s) are defined by the text that describes the parameter.</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>M</term>
<listitem>
<para xml:id="para_487727e6-49dc-4c09-a60d-e421d6c9c990">Mandatory usage</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>MF</term>
<listitem>
<para xml:id="para_105bda57-775a-4183-918e-cbc74437ce43">Mandatory with a fixed value</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>U</term>
<listitem>
<para xml:id="para_c8e841bf-1544-4c7d-b0a3-56d98bf3271b">The use of this parameter is a DIMSE Service User option</para>
</listitem>
</varlistentry>
  <varlistentry>
<term>UF</term>
<listitem>
<para xml:id="para_aa58a902-e75a-4ba3-9293-a6deed153cc8">User Option with a fixed value</para>
</listitem>
</varlistentry>
  </variablelist>
  </chapter>
<chapter label="6" status="1" xml:id="chapter_6">
    <title>Service Context</title>
  
  <para xml:id="para_dcf0885f-d38a-4be6-8f62-8f493e2b5b19">This section defines the DICOM Message Service Element and Protocol within the context of the DICOM Application Entity. Specifically, this section provides a model to clarify a number of concepts for digital imaging and communications and introduces key terms used throughout the Standard. This model has been used to partition the Application Layer of the DICOM Standard into separate parts.</para>
  <section label="6.1" status="2" xml:id="sect_6.1">
      <title>DICOM Communication Model for Message Exchange</title>
      <para xml:id="para_5c35538f-2812-452c-a224-9e65ff5b1805">
<olink targetdoc="PS3.1" targetptr="figure_5-1" xrefstyle="select: docname label"/> presents the general communication model of the DICOM Standard, which spans both network (on-line) and storage media interchange (off-line) communications.
          Application Entities may utilize any of the following transport mechanisms:</para>
      <itemizedlist>
          <listitem>
              <para xml:id="para_168e81ad-b03c-47db-9fd4-9260b97a465c">the DICOM Message Service and Upper Layer Service, which provides independence from specific physical networking communication support and protocols such as TCP/IP,</para>
          </listitem>
          <listitem>
              <para xml:id="para_67456292-d103-484c-a998-8444e64544ec">the DICOM Web Service API and HTTP Service, which allows use of common hypertext and associated protocols for transport of DICOM services,</para>
          </listitem>
          <listitem>
              <para xml:id="para_f3864a75-5bc3-47fd-a2a7-ed2d35ec99b5">the Basic DICOM File Service, which provides access to Storage Media independently from specific physical media storage formats and file structures, or</para>
          </listitem>
          <listitem>
              <para xml:id="para_ccc9facf-8efc-4ba0-9f83-3b35987de5da">DICOM Real-Time Communication, which provides real-time transport of DICOM metadata based on SMPTE and RTP.</para>
          </listitem>
      </itemizedlist>
      <para xml:id="para_b6116be0-8f53-48fe-a1e0-55564662e507">PS3.7 focuses on the DICOM Message Service and here the OSI Basic Reference Model is used to model the interconnection of medical imaging equipment.
          As shown in <xref linkend="figure_6.1-1" xrefstyle="select: label"/> several layers of communication protocols are distinguished. DICOM uses the OSI Upper Layer Service to separate the exchange of DICOM Messages at the Application Layer from the communication support provided by the lower layers.</para>
  <para xml:id="para_1c40cb20-5f79-41a3-9d5d-ff40ca121e9d">This OSI Upper Layer Service boundary allows peer Application Entities to establish Associations, transfer Messages and terminate Associations. For this boundary, DICOM has adopted the OSI Standards (Presentation Service augmented by the Association Control Service Element). It is a simple service that isolates the DICOM Application Layer from the specific stack of protocols used in the communication support layers.</para>
  <para xml:id="para_7257243f-a986-4e3b-8694-c55dc8436a16">The DICOM Upper Layer protocol augments TCP/IP. It combines the OSI upper layer protocols into a simple-to-implement single protocol while providing the same services and functions offered by the OSI stack.</para>
  <para xml:id="para_97efb1db-73e7-4924-89a6-47201d44de1f">The DICOM Upper Layer Service is defined in <olink targetdoc="PS3.8" targetptr="PS3.8" xrefstyle="select: labelnumber"/>.</para>
  <para xml:id="para_3a06082b-812e-40c7-86b1-5da7f53ee2a0">
<figure label="6.1-1" pgwide="1" xml:id="figure_6.1-1">
    <title>DICOM Communication Model for Message Exchange</title>
<mediaobject>
<imageobject>
<imagedata fileref="figures/PS3.7_6.1-1.svg"/>
<!--<imagedata fileref="part07_fromword_files/image002.png"/>-->
</imageobject>
</mediaobject>
</figure>
</para>
  </section>
<section label="6.2" status="2" xml:id="sect_6.2">
    <title>The DICOM Application Layer Structure</title>
  
  <para xml:id="para_1de6b582-1346-4b7c-9853-ae467e489f11">A DICOM Application Entity and the Service Elements it includes are shown in <xref linkend="figure_6.2-1" xrefstyle="select: label"/>.</para>
  <note>
    <para xml:id="para_3116ce89-7bc6-4dd5-b4b2-47483ab243d1">Annexes of this Part define certain aspects of the DICOM Application Entity.</para>
  </note>
  <para xml:id="para_af16197d-bc77-4e45-ba74-a99015789616">The heart of any DICOM Application Entity is specified by the following parts of the DICOM Standard:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_c27c7660-6be0-423d-9859-f7df12c2ffdf">
<olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>, Information Object Definitions, which provides data models and Attributes used as a basis for defining SOP Instances that are operated upon by the services defined in this [art. Such SOP Instances are used to represent real-world occurrences of images, studies, patients, etc.</para>
</listitem>
  <listitem>
<para xml:id="para_d9bbefdd-c5cc-4fd3-baa0-05a44fdae7c5">
<olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>, Service Class Specifications, which defines the set of operations that can be performed on SOP Instances. Such operations may include the storage, retrieval of information, printing, etc.</para>
</listitem>
  <listitem>
<para xml:id="para_afc1b2c2-7822-4363-b99f-ebe1eb36327c">
<olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>, Data Structure and Encoding, which addresses the encoding of the Data Sets exchanged to accomplish the above services</para>
</listitem>
  <listitem>
<para xml:id="para_23899180-31ae-4b19-9f50-f3ff5205f889">
<olink targetdoc="PS3.6" targetptr="PS3.6" xrefstyle="select: labelnumber"/>, Data Dictionary, which contains the registry of DICOM Data Elements used to represent Attributes of SOP Classes</para>
</listitem>
</itemizedlist>
  <para xml:id="para_4e3d49eb-8d13-4566-aa28-84b2bb21fe24">The DICOM Application Entity uses the Association and Presentation data services of the OSI Upper Layer Service defined in <olink targetdoc="PS3.8" targetptr="PS3.8" xrefstyle="select: labelnumber"/>. The Association Control Service Element (ACSE) augments the Presentation Layer Service with Association establishment and termination services. In the case of TCP/IP, the full equivalent of ACSE is provided by the DICOM Upper Layer Service. For the DICOM point-to-point stack, a minimum subset of ACSE is provided by the Session/Transport/Network Service.</para>
  <para xml:id="para_e90bc4f7-8560-4b41-bf3f-28050ac37413">The DICOM Application Entity uses the services provided by the DICOM Message Service Element. The DICOM Message Service Element specifies two sets of services.</para>
<itemizedlist>
  <listitem>
<para xml:id="para_5f41f37e-6545-4093-9edd-1ebbae6eeec2">DIMSE-C supports operations associated with composite SOP Classes and provides effective compatibility with the previous versions of the DICOM Standard.</para>
</listitem>
  <listitem>
<para xml:id="para_a93f6e73-1abe-409b-8033-160a07a9fa06">DIMSE-N supports operations associated with normalized SOP Classes and provides an extended set of object-oriented operations and notifications. It is based on the OSI System Management Model and more specifically on the OSI Common Management Information Services (CMIS) Service definition.</para>
</listitem>
</itemizedlist>
  <para xml:id="para_12cd5af9-318d-48d6-94a5-8a6010db92c4">
<figure label="6.2-1" pgwide="1" xml:id="figure_6.2-1">
<title>DICOM Application Layer Structure</title>
<mediaobject>
<imageobject>
<imagedata fileref="figures/PS3.7_6.2-1.svg"/>
<!--<imagedata fileref="part07_fromword_files/image004.png"/>-->
</imageobject>
</mediaobject>
</figure>
</para>
  <para xml:id="para_af05bb0e-07fd-4620-b304-40b7db16d8d0">The DIMSE-C and DIMSE-N services are supported by a single DIMSE protocol that uses the DICOM-specific Message formatting and encoding.</para>
  </section>
<section label="6.3" status="2" xml:id="sect_6.3">
    <title>DICOM Message Structure and Command Set</title>
  
  <para xml:id="para_31224615-902d-4978-8ab9-2994f6660f10">Information is communicated across the DICOM network interface in a DICOM Message. A Message is composed of a Command Set followed by a conditional Data Set (see <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/> for the definition of a Data Set). The Command Set is used to indicate the operations/notifications to be performed on or with the Data Set.</para>
  <para xml:id="para_75120d4f-b6b3-4c06-b5fe-7d8955804977">A Command Set is constructed of Command Elements. Command Elements contain the encoded values for each individual field of the Command Set per the semantics specified in the DIMSE protocol (see <xref linkend="sect_9.2" xrefstyle="select: label"/> and <xref linkend="sect_10.2" xrefstyle="select: label"/>). Each Command Element is composed of an explicit Tag, a Value Length, and a Value Field.</para>
  <para xml:id="para_58a045b0-db1f-4015-a0d8-bda26f88c2be">The overall structure of a DICOM Message is shown in <xref linkend="figure_6.3-1" xrefstyle="select: label"/>.</para>
  <para xml:id="para_0a554609-d411-4e99-86c8-4b6f6790bbf1">
<figure label="6.3-1" pgwide="1" xml:id="figure_6.3-1">
<title>DICOM Message Structure</title>
<mediaobject>
<imageobject>
<imagedata fileref="figures/PS3.7_6.3-1.svg"/>
<!--<imagedata fileref="part07_fromword_files/image006.png"/>-->
</imageobject>
</mediaobject>
</figure>
</para>
  <section label="6.3.1" status="3" xml:id="sect_6.3.1">
    <title>Command Set Structure</title>
  
  <para xml:id="para_4cc765d2-2901-45ce-a1b1-66dfeca56107">The Command Elements in a Command Set shall be ordered by increasing Command Element Tag number. A Command Element Tag uniquely identifies a Command Element and shall occur at most once in a Command Set. The encoding of the Command Set shall be Little Endian Byte Ordering as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>. The requirements for the existence of a Command Element in a Command Set are defined in the DIMSE protocol.</para>
  <note>
    <orderedlist numeration="arabic">
      <listitem>
        <para xml:id="para_faeaca4a-ef34-491f-bc4c-21e7c93a596e">The use of Private Command Elements has been retired in this version of the DICOM Standard.</para>
      </listitem>
      <listitem>
        <para xml:id="para_f15cf297-42d5-4338-beeb-4dad66398c6b">The encoding corresponds to the Implicit VR Data Element encoding defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>.</para>
      </listitem>
    </orderedlist>
  </note>
  <para xml:id="para_08cffd03-5993-40a8-bfea-c0aa484ccee2">A Command Element is composed of three fields; a Command Element Tag, a Value Length, and a Value Field.</para>
  <para xml:id="para_dbb4fb5f-46fe-452d-b2ba-9d02b1493369">Command Element Tag: An ordered pair of 16-bit unsigned integers representing the Group Number followed by the Element Number.</para>
  <note>
      <orderedlist>
          <listitem>
              <para xml:id="para_eafd7243-b6cc-45be-8ae6-d1e94a50f8f0">All Command Element Tags have the Group Number 0000.
                  See <xref linkend="chapter_E" xrefstyle="template:Annex %n"/> for the Registry of Command Elements, which provides a complete list of all Command Elements that can be used for the Command Set.</para>
          </listitem>
          <listitem>
              <para xml:id="para_4d79cd98-a177-4295-8dad-a09f45831688">In particular, the Command Set is not permitted to contain any Data Elements, such as those listed in <olink targetdoc="PS3.6" targetptr="PS3.6" xrefstyle="select: labelnumber"/>.</para>
          </listitem>
      </orderedlist>
  </note>
  <para xml:id="para_9ba310a8-e275-4d71-a838-a3b94af7c635">Value Length: A 32-bit unsigned integer representing the explicit Length as the number of bytes (even) that make up the Value. It does not include the length of the Command Element Tag or Value Length fields.</para>
  <para xml:id="para_39279bc6-132e-440f-be3a-d189e473ac4a">Value Field: An even number of bytes containing the Value(s) of the Command Element.</para>
  <para xml:id="para_304e987b-fd10-4710-94d9-10a43342f009">The command type of Value(s) stored in this field is specified by the Command Element's Value Representation (VR). The VR for a given Command Element can be determined using the Command Dictionary in <xref linkend="chapter_E" xrefstyle="template:Annex %n"/>. The VR of Command Elements shall agree with those specified in the Command Dictionary. The VR definitions can be found in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>
</para>
  <para xml:id="para_0906e49b-8c70-454e-a273-45c35c272798">The Value Multiplicity (VM) specifies how many Values with the VR can be placed in the Value Field. If the VM is greater than one, multiple Values shall be delimited within the Value Field as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>. The VM for a given Command Element can be determined using the Command Dictionary in <xref linkend="chapter_E" xrefstyle="template:Annex %n"/>.</para>
  <note>
    <orderedlist numeration="arabic">
      <listitem>
        <para xml:id="para_88cfe637-0efb-4a8a-b5fd-7e0423a2a714">The Command Length to End (0000,0001) Command Element is retired. Implementations may choose to send it for backward compatibility reasons. DICOM V3.0 conformant implementations must not rely on its presence for their operation.</para>
      </listitem>
      <listitem>
        <para xml:id="para_9d012a83-514c-42e2-a856-035df88f6ff3">The delimitation of the Message length is actually achieved by relying on the fact that the Presentation Data Value (conveying each Message fragment) is delimited as defined by the OSI Upper Layer Service and the associated Message Control Header (see <olink targetdoc="PS3.8" targetptr="PS3.8" xrefstyle="select: labelnumber"/>). This results from the fact that the DICOM V3.0 UL protocol or the OSI Presentation protocol explicitly conveys the length of a PDV.</para>
      </listitem>
    </orderedlist>
  </note>
  </section>
</section>
</chapter>
<chapter label="7" status="1" xml:id="chapter_7">
    <title>Service Overview</title>
  
  <para xml:id="para_2dc59a59-000b-4991-a2dd-efcd4b96a6dd">The DICOM Message Service Element supports communication between peer DIMSE Service Users. A DIMSE Service User acts in one of two roles:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_0a62b329-9560-42fd-9f5f-fc37ba1508b7">Invoking DIMSE Service User</para>
</listitem>
<listitem>
<para xml:id="para_dcdd6afc-fbfb-4d18-bbc4-9d1f8890267f">Performing DIMSE Service User</para>
</listitem>
</orderedlist>
  <para xml:id="para_f66b6cc9-89c0-4a1e-963b-d30a8dd0712a">DIMSE Service Users make use of service primitives that are provided by the DIMSE Service Provider. The DIMSE Service Provider is an abstraction of the totality of those entities that provide DIMSE services to peer DIMSE Service Users. A service primitive shall be one of the following types:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_a655da7d-a254-4cdd-82c5-47b259752bb7">Request primitive</para>
</listitem>
<listitem>
<para xml:id="para_19554dae-a682-467d-bc3f-cc4fa535ea7e">indication primitive</para>
</listitem>
<listitem>
<para xml:id="para_584f9942-fd8a-4b66-9432-57ca7220945f">response primitive</para>
</listitem>
<listitem>
<para xml:id="para_3c7a3a61-0bbb-487f-9900-2a2dae67ddc0">confirmation primitive</para>
</listitem>
</orderedlist>
  <para xml:id="para_2e0c0cf3-980c-476b-8aca-c743d20f9d27">These primitives (which are shown in <xref linkend="figure_7-1" xrefstyle="select: label"/>) are used as follows to successfully complete a DIMSE service:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_b6610ef8-76b7-4ea7-adc8-4d1c5bae3046">The Invoking DIMSE Service User issues a Request primitive to the DIMSE Service Provider.</para>
</listitem>
  <listitem>
<para xml:id="para_dd2f8abc-cb19-487b-8bac-687bd4f3fe33">The DIMSE Service Provider receives the Request primitive from the Invoking DIMSE Service User and issues an indication primitive to the Performing DIMSE Service User.</para>
</listitem>
  <listitem>
<para xml:id="para_0781b798-e1a8-4586-8fbf-37675b369dbe">The Performing DIMSE Service User receives the indication primitive from the DIMSE Service Provider and performs the requested service.</para>
</listitem>
  <listitem>
<para xml:id="para_2401321e-39f1-4272-915f-652829b58c30">The Performing DIMSE Service User issues a response primitive to the DIMSE Service Provider.</para>
</listitem>
  <listitem>
<para xml:id="para_15df5d8c-e1c4-4977-8ad8-34419ec67298">The DIMSE Service Provider receives the response primitive from the Performing DIMSE Service User and issues a confirmation primitive to the Invoking DIMSE Service User.</para>
</listitem>
  <listitem>
<para xml:id="para_4afc3a13-35dd-4560-b088-0c635234967e">The Invoking DIMSE Service User receives the confirmation primitive from the DIMSE Service Provider completing the DIMSE service.</para>
</listitem>
</itemizedlist>
  <section label="7.1" status="2" xml:id="sect_7.1">
    <title>Service Types</title>
  
  <para xml:id="para_bb60924e-fe0e-4262-bc23-257c1adf5ee1">DIMSE provides two types of information transfer services that are used by DICOM Application Entities:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_767d6318-943d-4a3f-b98e-d3031970fd7a">a notification service</para>
</listitem>
<listitem>
<para xml:id="para_37931404-2562-4967-9d70-1153b963a1e9">an operation service</para>
</listitem>
</orderedlist>
  <para xml:id="para_4271407f-e8a6-4201-9051-142d1323546a">
<figure label="7-1" pgwide="1" xml:id="figure_7-1">
<title>DIMSE Service Primitives</title>
<mediaobject>
<imageobject>
  <imagedata fileref="figures/PS3.7_7-1.svg"/>
<!--<imagedata fileref="part07_fromword_files/image008.png"/>-->
</imageobject>
</mediaobject>
</figure>
</para>
  <para xml:id="para_37c1671a-de66-4f68-bd2e-35b58b2121a3">Notification services enable one DICOM Application Entity to notify another about the occurrence of an event or change of state. The definition of the notification and the consequent behavior of the Application Entities is dependent upon the Service Class and Information Object Definitions. See <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/> and <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>.</para>
  <para xml:id="para_09154a57-7aa8-45ad-b67e-1fb0b3f2b5de">Operation services enable one DICOM Application Entity to explicitly request an operation to be performed upon a SOP Instance managed by another DICOM Application Entity.</para>
  </section>
<section label="7.2" status="2" xml:id="sect_7.2">
    <title>DIMSE Service User Interaction</title>
  
  <para xml:id="para_ee619ba0-8a78-4c62-9296-1b6d3776ff85">The DICOM Message Service Element receives notification and operation requests and their related information from the DIMSE Service User. Two DICOM Application Entities take the roles as peer DIMSE Service Users in order to exchange notifications and operations.</para>
  <para xml:id="para_c9e4f108-28c6-4960-b4a8-9a19feaeb034">A notification or operation is implemented as a request/response interaction carried out within the context of an established application Association. Typically, one DIMSE Service User requests that a particular operation be performed (or notification be processed) and the other DIMSE Service User attempts to perform the operation (or process the notification) and then reports the outcome of the attempt.</para>
  <para xml:id="para_670bc20c-9051-418c-a124-90d3ba2dc775">When engaging in the operations or notifications, the DIMSE Service User takes on one of two roles:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_e6a8e7a8-5fb4-4fc0-9efc-e374fb32bd11">it performs operations (on SOP Instances for which it has responsibility) that were invoked by a peer DIMSE Service User. It may also emit change-of-state notifications for SOP Instances to one or more peer DIMSE Service Users. These notifications may be invoked as a result of operations initiated by other DIMSE Service Users.</para>
</listitem>
<listitem>
<para xml:id="para_07fad20a-b3a8-4b05-9f01-93de33f8024f">it invokes the performance of an operation on a peer DIMSE Service User. It may also receive notifications from a peer DIMSE Service User.</para>
</listitem>
</orderedlist>
  <para xml:id="para_ec9253e1-e2d4-42f0-9fc3-9d969fcc4ece">These roles are depicted in <xref linkend="figure_7.2-1" xrefstyle="select: label"/>.</para>
  <note>
    <orderedlist numeration="arabic">
      <listitem>
        <para xml:id="para_723450d9-4c60-4975-b298-0cfdc10f6fe6">Role a) (called the Agent role in ISO terminology) is used by an implementation that conforms to a DICOM Service Class as an SCP.</para>
      </listitem>
      <listitem>
        <para xml:id="para_7ff823c7-2875-403d-9d25-1c72a0be01aa">Role b) (called the Manager role in ISO terminology) is used by an implementation that conforms to a DICOM Service Class as an SCU.</para>
      </listitem>
    </orderedlist>
  </note>
  <para xml:id="para_2fdb23f6-524e-4772-bbee-c280b0858379">
<figure label="7.2-1" pgwide="1" xml:id="figure_7.2-1">
<title>Operation and Notification Flow</title>
<mediaobject>
<imageobject>
<imagedata fileref="figures/PS3.7_7.2-1.svg"/>
<!--<imagedata fileref="part07_fromword_files/image010.png"/>-->
</imageobject>
</mediaobject>
</figure>
</para>
  </section>
<section label="7.3" status="2" xml:id="sect_7.3">
    <title>Service Modes</title>
  
  <para xml:id="para_38644787-e028-44ed-a1c9-7fcf0247c3a6">Operations and notifications, on an Association, are used in one of the following two modes:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_8b8e8cfe-3c5d-4996-b18f-e51d3cac22d0">synchronous</para>
</listitem>
<listitem>
<para xml:id="para_f9defa15-7a7f-42c1-84ae-ca2ba47464ca">asynchronous</para>
</listitem>
</orderedlist>
  <para xml:id="para_b0b4137b-a1e9-4b03-b711-92f9e96237af">In the synchronous mode, the Invoking DIMSE Service User, on an established Association, requires a response from the Performing DIMSE Service User before invoking another operation or notification.</para>
  <para xml:id="para_77ac80cf-ec8d-419f-b7df-831ce4cecfa1">In the asynchronous mode, the Invoking DIMSE Service User, on an established Association, may continue to invoke further operations or notifications to the Performing DIMSE Service User without awaiting a response. In the asynchronous mode, the Performing DIMSE Service User may respond to the operations or notifications in a different order than they were received.</para>
  <para xml:id="para_fc259c71-3f49-4826-93fe-04486c22d36e">The mode selection (synchronous or asynchronous) is determined at Association establishment time. The synchronous mode serves as the default mode and shall be supported by all DIMSE Service Users. The asynchronous mode is optional and the maximum number of outstanding operations/notifications is negotiated during Association establishment. This negotiation is accomplished by Application Association Information as defined in <xref linkend="chapter_D" xrefstyle="template:Annex %n"/>.</para>
  </section>
<section label="7.4" status="2" xml:id="sect_7.4">
    <title>Association Services</title>
  
  <para xml:id="para_8275e01a-c08f-49c2-9aea-7b4b1d3a6617">The DICOM Message Service Element does not provide separate services for the establishment and termination of application Associations. This section provides an overview of how an Application Entity using the DIMSE service uses the Association Services defined in <olink targetdoc="PS3.8" targetptr="PS3.8" xrefstyle="select: labelnumber"/>.</para>
  <para xml:id="para_889b702b-e4f8-46e8-ac1f-d2a2a3bec933">During the Association establishment phase, a DIMSE Service User shall exchange initialization information using parameters of the A-ASSOCIATE Upper Layer Service (see <xref linkend="figure_7.4-1" xrefstyle="select: label"/>) that include:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_700775e2-abb3-42f4-b81c-738a7dff1f14">Application context</para>
</listitem>
  <listitem>
<para xml:id="para_46258eaf-d82d-47e8-bb9f-d1e6d5f8a018">Presentation and session requirements</para>
</listitem>
  <listitem>
<para xml:id="para_cf6f9d7c-7a1d-45e6-889c-44594fe8ad7e">DIMSE-specific user information</para>
</listitem>
  <listitem>
<para xml:id="para_ac8054ee-7873-4e67-a328-db7ba100534b">Application Association Information</para>
</listitem>
</itemizedlist>
  <para xml:id="para_3fdee113-1092-45c3-8bd9-032f965c5793">The A-RELEASE and A-ABORT Services defined in <olink targetdoc="PS3.8" targetptr="PS3.8" xrefstyle="select: labelnumber"/> shall be used for the termination of an Association.</para>
  <note>
    <para xml:id="para_2b86888e-ca53-4d03-b29e-a344f2cd0c90">The rules defining how the Association Services are used by a DIMSE Service User are defined in <xref linkend="chapter_D" xrefstyle="template:Annex %n"/>.</para>
  </note>
  <section label="7.4.1" status="3" xml:id="sect_7.4.1">
    <title>Association Establishment</title>
  
  <para xml:id="para_0dffd010-3523-49cc-8bba-05f6e843d445">The A-ASSOCIATE Service is invoked by a DIMSE Service User to establish an Association with a peer DIMSE Service User. Association establishment is always the first phase of DICOM Message Exchange.</para>
  <para xml:id="para_0475c4fe-5c5b-45f7-8ec3-5c100548f1ed">The initiating DIMSE Service User and the responding DIMSE Service User shall include Application Association Information on the request and response primitive respectively. The meaning of this parameter is Application Context specific. For more information on the use of the Application Association Information, see <xref linkend="chapter_D" xrefstyle="template:Annex %n"/>.</para>
  </section>
<section label="7.4.2" status="3" xml:id="sect_7.4.2">
    <title>Association Release</title>
  
  <para xml:id="para_a35abaee-439f-4405-834c-7d8b8f955e97">The A-RELEASE Service is invoked by a DIMSE Service User to request the orderly termination of an Association between peer DIMSE Service Users. This Part of the Standard does not specify any use of the parameters of the A-RELEASE service.</para>
  <para xml:id="para_f2063f36-ca00-4181-9186-ad0a7a9b2e25">
<figure label="7.4-1" pgwide="1" xml:id="figure_7.4-1">
<title>DICOM Application Entity and Association</title>
<mediaobject>
<imageobject>
<imagedata fileref="figures/PS3.7_7.4-1.svg"/>
<!--<imagedata fileref="part07_fromword_files/image012.png"/>-->
</imageobject>
</mediaobject>
</figure>
</para>
  <para xml:id="para_a7d82eaa-604c-45b2-9f24-0d9ffb226898">The A-ABORT Service is invoked by a DIMSE Service User to request the abrupt termination of the Association between peer DIMSE Service Users. The A-ABORT Invoking DIMSE Service User shall include (within the A-ABORT user information field) the Abort Source parameter. The Abort Source parameter indicates the initiating source of the abort. It takes one of the following symbolic values:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_754c7032-daa6-4aff-b695-4fc4893ee5dd">DIMSE Service Provider</para>
</listitem>
  <listitem>
<para xml:id="para_78a78d60-7ec0-4158-8cfb-550e239f6b7f">DIMSE Service User</para>
</listitem>
</itemizedlist>
  <para xml:id="para_be998645-a42a-4781-813f-ae9dc8fce203">Reference <olink targetdoc="PS3.8" targetptr="PS3.8" xrefstyle="select: labelnumber"/> for more information on the A-RELEASE and A-ABORT services.</para>
  </section>
</section>
<section label="7.5" status="2" xml:id="sect_7.5">
    <title>DIMSE Services</title>
  
  <para xml:id="para_c2b450ae-34bf-4b1d-b91d-864e9a139455">Because the manner in which operations applied to Composite SOP Instances differ from operations and notifications applied to Normalized SOP Instances, two groups of DIMSE services are defined:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_3fcad219-ff46-4e65-bff7-0fb31469ad7e">DIMSE-N: those services applicable to Normalized SOP Instances</para>
</listitem>
  <listitem>
<para xml:id="para_873b7323-b787-40e9-8ac6-4cb2f3e49142">DIMSE-C: those services applicable to Composite SOP Instances</para>
</listitem>
</itemizedlist>
    <table frame="box" label="7.5-1" rules="all" xml:id="table_7.5-1">
    <caption>DIMSE Services</caption>
    <thead>
      <tr valign="top">
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_712417c1-7eb2-47a9-acc8-e1c45ec50070">
            <emphasis role="bold">Name</emphasis>
          </para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_6380b3fb-64e3-4d06-bc36-8f9e20c54767">
            <emphasis role="bold">Group</emphasis>
          </para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_4a7df110-5d6e-4ac5-894b-e0c8d372b791">
            <emphasis role="bold">Type</emphasis>
          </para>
        </td>
      </tr>
      
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_02f773c9-0201-4701-9e7c-0b2f3b9a661a">C-STORE</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5b937473-cd69-49b2-8f8d-af6396c12392">DIMSE-C</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c56bef1c-ed58-44c6-9e19-2758b8422d75">operation</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_418822b0-f1c9-4898-b7e2-cac824f78f92">C-GET</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e24ddfab-f627-4fbe-b0e1-fb0d6a1ebcf2">DIMSE-C</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_714a63d7-cb22-4b90-be50-640fd4341b93">operation</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_038d1f15-cf85-4b0f-94ed-4348841f9d54">C-MOVE</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3c308a99-bc48-4283-99ff-ebe8062f5736">DIMSE-C</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_4027f3e7-1e5f-49d6-b18b-7754765b4610">operation</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3e46d378-0454-4212-ac42-517e36ae4a11">C-FIND</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_06a83569-5615-4aad-98f5-7206daddec3a">DIMSE-C</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6943864d-bff0-48d8-9ddc-af78f1d66c8f">operation</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_eea60d93-7ac1-4ff9-a571-d826699fd6e2">C-ECHO</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_36079dbb-44b9-41e8-812f-00e155481f81">DIMSE-C</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_24cd5a6b-152b-4853-86b3-0541d73eef36">operation</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a0d53837-5c2e-4547-927c-c0592c5d68af">N-EVENT-REPORT</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c7da560a-b224-438f-9e40-b6ef9d37e647">DIMSE-N</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a14a2ed6-c023-422e-9958-07b2bdbb5b63">notification</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d4d4b516-ff55-4a45-a529-c9756667a7dc">N-GET</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_94903582-aaf5-45ae-b3aa-a5143ae41fc6">DIMSE-N</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_2980f612-b9fc-4c61-8b0e-6d2227bf567c">operation</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d7e38f86-939c-450f-be29-8eaaee00dec0">N-SET</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_917b4f41-e14d-4256-b506-87b66c5566d8">DIMSE-N</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_90518566-b370-4edf-b0b5-477fd2220d9a">operation</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a1dc5f9e-627e-438e-903d-f989df255c16">N-ACTION</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a20f422b-cd6e-4640-a5c3-1c5fa0623bcc">DIMSE-N</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_04b3ae9e-0f5c-4867-933a-601c83fc790c">operation</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0069fd30-20cf-488b-a3dd-31f8b65eaad2">N-CREATE</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_71f5b278-c99b-4684-a586-2e0692bbca1b">DIMSE-N</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_204ded14-a445-45b2-97e6-519798b57322">operation</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3f1a75e6-e82d-43d9-970e-640261ac2ad5">N-DELETE</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_956264a6-78ce-4704-9165-45ed2395ca5c">DIMSE-N</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_7e173690-a962-4e82-8ab4-ca8fac0408f5">operation</para>
      </td>
    </tr>
    </tbody>
  </table>
  <note>
    <para xml:id="para_04b483f3-8940-41d4-9e48-d950ec1d6372">Use of the Dialog command, supported in previous versions of this Standard, has been retired.</para>
  </note>
  <section label="7.5.1" status="3" xml:id="sect_7.5.1">
    <title>DIMSE-C Services</title>
  
  <para xml:id="para_bc588002-b8f1-4cd3-88d5-7e1754cc8c7d">The DIMSE-C services allow a DICOM Application Entity to explicitly request an operation by another DICOM Application Entity on Composite SOP Instances. The operations allowed are intended to be effectively compatible with those provided by previous versions of this Standard. DIMSE-C provides only operation services.</para>
  <section label="7.5.1.1" status="4" xml:id="sect_7.5.1.1">
    <title>Operation Services</title>
  
  <para xml:id="para_332f970f-a1c4-4272-a553-0d3dc0e38620">DIMSE-C provides the following operation services that are all confirmed services and as such a response is expected:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_6d95bfc3-9847-4fac-905b-4fa7ccbfe4fe">The C-STORE service is invoked by a DIMSE Service User to request the storage of Composite SOP Instance information by a peer DIMSE Service User.</para>
</listitem>
<listitem>
<para xml:id="para_ce83afed-785f-4fcf-b219-25424e493798">The C-FIND service is invoked by a DIMSE Service User to match a series of Attribute strings against the Attributes of the set of SOP Instances managed by a peer DIMSE Service User. The C-FIND service returns for each match a list of requested Attributes and their values.</para>
</listitem>
<listitem>
<para xml:id="para_bfe41d45-f52f-4493-b9c4-461bf826c52c">The C-GET service is invoked by a DIMSE Service User to fetch the information for one or more Composite SOP Instances from a peer DIMSE Service User, based upon the Attributes supplied by the Invoking DIMSE Service User.</para>
</listitem>
<listitem>
<para xml:id="para_cd21c4b9-7c4c-4cbb-8f75-60c079ba7148">The C-MOVE service is invoked by a DIMSE Service User to move the information for one or more Composite SOP Instances from a peer DIMSE Service User, to a third party DIMSE Service User, based upon the Attributes supplied by the Invoking DIMSE Service User</para>
</listitem>
<listitem>
<para xml:id="para_672bd5a9-05f8-47aa-8fbf-6db3ab07c5a4">The C-ECHO service is invoked by a DIMSE Service User to verify end-to-end communications with a peer DIMSE Service User.</para>
</listitem>
</orderedlist>
  <note>
    <orderedlist>
      <listitem>
        <para xml:id="para_1299c4d4-9ace-4df6-be01-ca7b845c7160">The major differences between a C-GET and a C-MOVE operation are that the:</para>
        <orderedlist numeration="loweralpha">
          <listitem>
<para xml:id="para_ec36a73e-366f-4dc9-9b51-722b4cb070e3">C-STORE sub-operations resulting from a C-GET are performed on the same Association as the C-GET. With a C-MOVE, the resulting C-STORE sub-operations are performed on a separate Association.</para>
</listitem>
          <listitem>
<para xml:id="para_89a4a910-0a0f-4aa2-b2de-4ad8593f67f4">C-MOVE operation supports C-STORE sub-operations being performed with an Application Entity that is not the one that initiated the C-MOVE (third party move).</para>
</listitem>
        </orderedlist>
      </listitem>
      <listitem>
<para xml:id="para_782c2f63-8153-4bbd-9971-84860c7e5162">In the case where an Application Entity wishes to request that it receives one or more images for storage, it may use either a C-GET operation or a C-MOVE to itself. It is expected that in most environments the C-MOVE is a simpler solution despite the fact that two Associations are required. The use of the C-GET service may not be widely implemented. It may be implemented in special cases where a system does not support multiple Associations. It was left in this version of the Standard for backward compatibility with previous versions of the Standard.</para>
      </listitem>
    </orderedlist>
  </note>
    </section>
</section>
<section label="7.5.2" status="3" xml:id="sect_7.5.2">
    <title>DIMSE-N Services</title>
  
  <para xml:id="para_002a473d-0e31-453a-9ad2-9c4fd002a9e0">The DIMSE-N services provide both notification and operation services applicable to Normalized SOP Instances.</para>
  <section label="7.5.2.1" status="4" xml:id="sect_7.5.2.1">
    <title>Notification Service</title>
  
  <para xml:id="para_c61f692b-5712-414b-a706-c0db03815ad7">DIMSE-N provides a single Notification Service, the N-EVENT-REPORT. The N-EVENT-REPORT service is invoked by a DIMSE Service User to report an event about a SOP Instance to a peer DIMSE Service User. This service is a confirmed service and a response is expected.</para>
  </section>
<section label="7.5.2.2" status="4" xml:id="sect_7.5.2.2">
    <title>Operation Services</title>
  
  <para xml:id="para_82931059-8653-420f-93d5-977952e377b5">DIMSE-N provides the following operation services that are all confirmed services and as such a response is expected:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_9134bdbe-6928-42e8-8c8b-cb559641f096">The N-GET service is invoked by a DIMSE Service User to request the retrieval of information from a peer DIMSE Service User.</para>
</listitem>
<listitem>
<para xml:id="para_f5efaa50-3885-4ecd-84f4-411e9b2de3f9">The N-SET service is invoked by a DIMSE Service User to request the modification of information by a peer DIMSE Service User.</para>
</listitem>
<listitem>
<para xml:id="para_0400c2f3-d0c0-4860-ae32-31b6646c619d">The N-ACTION service is invoked by a DIMSE Service User to request a peer DIMSE Service User to perform an action.</para>
</listitem>
<listitem>
<para xml:id="para_6fa51a38-8acd-4d65-837d-4659fb010003">The N-CREATE service is invoked by a DIMSE Service User to request a peer DIMSE Service User to create an instance of a SOP Class.</para>
</listitem>
<listitem>
<para xml:id="para_bca3a99a-4e35-44ce-a696-2a8dce874091">The N-DELETE service is invoked by a DIMSE Service User to request a peer DIMSE Service User to delete an instance of a SOP Class.</para>
</listitem>
</orderedlist>
  </section>
</section>
<section label="7.5.3" status="3" xml:id="sect_7.5.3">
    <title>DIMSE Procedures</title>
  
  <para xml:id="para_2992c482-6dfe-4deb-aca4-18a720dce02c">All DIMSE operations and notifications are confirmed services. The Performing DIMSE Service User shall report the response of each operation or notification over the same Association on which the operation or notification was invoked.</para>
  <para xml:id="para_b525b236-e592-4fe6-96fc-02d391edd07b">Each DIMSE service is accomplished through the use of one or more service primitives. How the peer DIMSE Service Users utilize and react to the service primitives are defined by the service procedures.</para>
  <section label="7.5.3.1" status="4" xml:id="sect_7.5.3.1">
    <title>Sub-Operations</title>
  
  <para xml:id="para_ace441f2-e460-4179-a7a7-4610c97796d2">Some DIMSE services are atomic in that the service is performed by one operation or notification. In such a case the DIMSE service primitives are used by peer DIMSE Service Users to invoke and perform the operation or notification.</para>
  <para xml:id="para_c2b1cb69-154f-45a8-8670-d5b47a540f74">Other DIMSE services require the use of one or more sub-operations to perform the service. In such cases DIMSE service primitives are used by peer DIMSE Service Users to invoke and perform each sub-operation. How and when the sub-operation service primitives are used is defined by the procedures for the DIMSE service.</para>
  </section>
<section label="7.5.3.2" status="4" xml:id="sect_7.5.3.2">
    <title>Multiple Responses</title>
  
  <para xml:id="para_8eede626-1987-43e5-b0a8-64d646b2a515">Each DIMSE service requires one or more response primitives as a result of the invocation of the service. How and when the multiple response primitives are used is defined by the procedures for the DIMSE service. Whether multiple responses are returned is conditional upon the information included in the Request primitive by the DIMSE Service User.</para>
  </section>
<section label="7.5.3.3" status="4" xml:id="sect_7.5.3.3">
    <title>Cancellation</title>
  
  <para xml:id="para_60aea90c-2749-44c8-9c36-2404b8dade1e">Certain DIMSE services permit the cancellation of the service through the use of service primitives. This allows an Invoking DIMSE Service User to request termination of a DIMSE service after completion of the request service primitive but prior to completion of the confirm service primitive.</para>
  <para xml:id="para_940385fe-d4d8-4ea7-aaba-8a1d6e973db4">
<xref linkend="table_7.5-2" xrefstyle="select: label"/> lists each DIMSE service and its related procedure information. The complete specifications for the service procedures are defined in Sections 9 and 10 for DIMSE-C and DIMSE-N respectively.</para>
    <table frame="box" label="7.5-2" rules="all" xml:id="table_7.5-2">
    <caption>DIMSE Services and Procedures</caption>
    <thead>
      <tr valign="top">
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_1e50547e-848b-4964-83bd-b865cfcd1688">
            <emphasis role="bold">Name</emphasis>
          </para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_e06af51d-c9d9-40af-8199-dbb68c97bb25">
            <emphasis role="bold">Sub-Operations</emphasis>
          </para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_d4656981-b6f4-4fd8-9782-a63ec1dea805">
            <emphasis role="bold">Multiple Responses</emphasis>
          </para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_85c33a1e-d092-4a4b-8cb2-cdc8548b2e72">
            <emphasis role="bold">Cancel</emphasis>
          </para>
        </td>
      </tr>
      
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_79fbebc6-0d8d-4a4f-afe8-4f15735e9cbf">C-STORE</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9ade4462-19eb-4c1d-8d04-04dcb4a59c5f">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_758ffbeb-12ac-4920-a518-3642cda1ccf2">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d3ce77a5-792d-4169-b7ce-ade11ba69a68">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_03ac4a08-8679-49bb-8c2f-60bfce2b2321">C-GET</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_3a9b4a34-3a9a-45f0-8fe3-2f1d1795d1c4">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_bdbcfe0a-05df-4253-babc-05a1b9d0a993">C</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_43476af8-5b1e-40a2-a53f-b73a85d47496">M</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_054e7321-7dbc-40db-82e9-5587ca58612e">C-MOVE</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6cbe1892-4c10-4def-96ca-1f40bb8e6a67">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_10c2b62c-eb75-44fb-9816-fcc1f8397c98">C</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1a88e244-a251-4df1-a4c9-8f18f40a6190">M</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_962929bb-063d-42bb-9992-9cd73b5288a1">C-FIND</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d23c1422-81c4-4b9c-847a-f666a05a1196">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e180b5d2-da7a-48a9-b5e3-263f89258b34">C</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a4d96144-b4ce-448a-aee5-eb7bdbe8f569">M</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_bd0bc196-9308-4b15-9ba3-9cd397682499">C-ECHO</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b4496bbb-7e1e-4e56-a14b-13ca7d610fe5">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4b4ebdf3-b9bc-4c2c-bc7b-d25ce477f384">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_14ca7e0f-772e-4ba7-a31c-2f08dc8d9187">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_aedebd53-1964-48c3-979c-ba90443289bf">N-EVENT-REPORT</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0ad964ad-021d-42cf-a942-8879db36b7bc">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_bae4288f-e871-4f7f-be5c-a479a65803d4">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4c28b558-3ac0-48c9-8e3d-3826efcfe7cb">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_86f69b16-c89b-4184-8928-10307a6bbfea">N-GET</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_92dbfe1c-4dfe-4dfe-9839-5267bedf1b3d">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b7e90959-fe1a-4c42-a066-7f7f16cdce0e">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_91232517-0a0d-4c88-92d8-3ef96b0e389f">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e378e2d0-0772-4645-b29d-c3a698f97a7a">N-SET</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2e3cd47a-6c9b-42d2-8571-2185b9a2c6ab">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8ea5bf8e-5333-438b-b151-4358a5530631">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9df4e07b-73f3-4cd6-bff7-a4c8cf21128a">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3df58131-93d2-4537-8458-3c2f988f0a5c">N-ACTION</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_3966f5b8-2154-4e27-acfe-944d5148bfa2">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_098fb3c8-7dd9-44a1-a151-4187398e8338">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f90ff958-32c4-465d-b458-abd153689fa1">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_7811ec07-99b5-4b10-be63-cd75c4b3081a">N-CREATE</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e2d8285f-1799-44c0-9091-91a622ea6083">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9092357e-8dc2-4ad6-9b50-d70e3e43ffbf">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_30aa1780-720f-4968-a9f1-63ee7ce09727">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_662d56d6-6ae3-4205-aa8d-a0a499a5cee6">N-DELETE</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_86d03fca-33f2-4ae2-8aeb-4bb2c1cac7c6">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_13f5bd88-e241-4d7b-a40b-2b122e05aec8">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_62964e29-4db3-4d3e-907d-a2937600472f">-</para>
      </td>
    </tr>
    </tbody>
  </table>
  </section>
</section>
</section>
</chapter>
<chapter label="8" status="1" xml:id="chapter_8">
    <title>Protocol Overview</title>
  
  <section label="8.1" status="2" xml:id="sect_8.1">
    <title>DIMSE Protocol</title>
  
  <para xml:id="para_c66694bf-3a2d-4f9c-b7e6-08c56a845be6">This Section provides an overview of the DIMSE protocol machine. The DIMSE protocol machine defines the procedures and the encoding rules necessary to construct Messages used to exchange command requests and responses between peer DIMSE Service Users (e.g., two DICOM Application Entities). The relationship between Messages and the different types of service primitives is shown in <xref linkend="figure_7-1" xrefstyle="select: label"/>.</para>
  <para xml:id="para_bc84b0e6-5faa-4b2e-a97c-2a05bb721bcb">The DIMSE protocol machine accepts DIMSE Service User request and response service primitives and constructs Messages defined by the procedures defined in 9.3 and 10.3. The DIMSE protocol machine accepts Messages and passes them to the DIMSE Service User by the means of indication and confirmation service primitives.</para>
  <para xml:id="para_9c43318d-5e77-42d3-b525-68ba017a00dd">Procedures define the rules for the transfer of Messages that convey command requests and responses. These rules define interpretation of the various fields in the command part of the Message. They do not define what an Invoking DIMSE Service User should do with the information (the Data Set part of the Message) it requested nor how a Performing DIMSE Service User should process the operation.</para>
  <para xml:id="para_e50f4a3a-972c-4f40-84eb-634d9a396a41">Messages may be fragmented. The fragmentation of Messages exchanged between peer DICOM Application Entities and the P-DATA service used to exchange these Message fragments are defined in <xref linkend="chapter_F" xrefstyle="template:Annex %n"/>.</para>
  <note>
    <para xml:id="para_29e49108-4b41-4c2a-87fb-bad1f0b32d43">These Message fragments are called Application Protocol Data Units (APDUs) by the OSI construct.</para>
  </note>
  <para xml:id="para_c8b4baf3-3a05-4644-9eb0-5e9f0ff576f3">The Invoking DIMSE Service User Request primitive results in a Message carrying a Command Request (with an optional associated Data Set). Each Message induces an indication primitive to the Performing DIMSE Service User.</para>
  <para xml:id="para_994a5be8-4b07-48f9-b522-66ebb0a81953">The Performing DIMSE Service User response primitives result in a Message carrying a Command Response (with an optional associated Data Set). Each Message induces a confirmation primitive to the Invoking DIMSE Service User.</para>
  </section>
<section label="8.2" status="2" xml:id="sect_8.2">
    <title>Association Protocol</title>
  
  <para xml:id="para_7dddd977-4921-45ac-a73f-a9a77770ab1f">The establishment of an Association involves two DIMSE Service Users, one that is the Association-requestor and one that is the Association-acceptor. A DIMSE Service User may initiate an Association establishment by using the A-ASSOCIATE service described in <olink targetdoc="PS3.8" targetptr="PS3.8" xrefstyle="select: labelnumber"/>.</para>
  <para xml:id="para_f5e4307f-c8a2-4bf9-9ba6-4997ca3a64ea">Included in the parameters of the A-ASSOCIATE service is the Application Context that specifies, among other things, the rules required for the coordination of initialization information corresponding to different DICOM Application Entities. The Application Contexts permitted for DIMSE are specified in <xref linkend="chapter_A" xrefstyle="template:Annex %n"/>.</para>
  </section>
<section label="8.3" status="2" xml:id="sect_8.3">
    <title>Conformance</title>
  
  <para xml:id="para_bf47f3b1-2e2d-4271-bfa2-c45ba89901d8">Implementers conform to the DIMSE protocol only by conformance to a SOP class as defined in <olink targetdoc="PS3.2" targetptr="PS3.2" xrefstyle="select: labelnumber"/> and <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>. Implementers do not conform directly to the DIMSE protocol, and are not required to include a statement about DIMSE conformance in conformance statements except as required in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>.</para>
  </section>
</chapter>
<chapter label="9" status="1" xml:id="chapter_9">
    <title>DIMSE-C</title>
  
  <section label="9.1" status="2" xml:id="sect_9.1">
    <title>Services</title>
  
  <section label="9.1.1" status="3" xml:id="sect_9.1.1">
    <title>C-STORE Service</title>
  
  <para xml:id="para_d31b46af-b77d-4d09-9acb-5b74bafe5041">The C-STORE service is used by a DIMSE Service User to store a composite SOP Instance on a peer DIMSE Service User. It is a confirmed service.</para>
  <section label="9.1.1.1" status="4" xml:id="sect_9.1.1.1">
    <title>C-STORE Parameters</title>
  
  <para xml:id="para_f3e807d5-1075-4435-99b7-10da6eb9dc8f">
<xref linkend="table_9.1-1" xrefstyle="select: label"/> lists the parameters of this service.</para>
    <table frame="box" label="9.1-1" rules="all" xml:id="table_9.1-1">
    <caption>C-STORE Parameters</caption>
    <thead>
      <tr valign="top">
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_6dcffa4d-a830-47ab-b84a-6e7b9ce476e2">
            <emphasis role="bold">DIMSE-C Parameter Name</emphasis>
          </para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_3dc49ebf-ffa2-4933-b9ca-f96aa348dfe6">
            <emphasis role="bold">Req/Ind</emphasis>
          </para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_0835746c-b8ae-4e09-b0cb-9da9fd70cd53">
            <emphasis role="bold">Rsp/Conf</emphasis>
          </para>
        </td>
      </tr>
      
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_82967186-140a-4a46-80a2-75f21c656f09">Message ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4de6627d-9873-447f-97b6-0b6700f93b5e">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f4ecc66f-7a24-49f6-9c30-0fc9e852b121">U</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b0d39bb0-929d-4d63-8755-de28d7caf8a2">Message ID Being Responded To</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_19e47cf2-88ab-4259-aeeb-0159319f01f5">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e7afd735-1034-4557-9671-c9b4b1120731">M</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_08e62272-18c8-4504-907a-1e840e1c7c1d">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0ec93aa1-c720-41b5-a8b8-a26954fdf60d">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_eacb393c-1f6b-4d45-ae72-76604b3964ac">U(=)</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f747b343-160a-4bf3-af45-af8adb1e956c">Affected SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_31d11b86-0c74-49f8-8c2d-7418057329cd">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b5752280-2874-4388-8f41-4164c5553ff3">U(=)</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_7b210854-7ad0-4047-b325-10ad1ecd0902">Priority</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a0c831b7-390f-4736-911c-57432db34a68">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9bf0aade-ad06-482f-9379-fa97768b192e">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_014d88d8-5c8c-42a6-a784-c1fe3b953a24">Move Originator Application Entity Title</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6250f2c1-45ee-4702-89ff-0d9ce7c1eebc">U</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6a5bc8a3-99ce-4bec-933f-aef7bd53b706">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_bbe4f730-41c4-4908-9c9b-8c05e9bfcafc">Move Originator Message ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_23108d91-7f59-4473-96b6-2756aa63fd53">U</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_24d15ea4-385e-4b22-a6ca-0ab05580cfe0">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1177cf0a-9a81-497c-a579-8ad77ec19c8c">Data Set</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1eb13a93-8109-4642-8396-1ac2fc8d9a01">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f51f44f0-0ffc-482e-8567-d6ae00fedfdd">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_15b506fb-960d-4555-baee-2c6c0044cf9a">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1d82ec38-d602-48d8-bae0-219657a1a668">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e21bcbd6-fb8c-40f6-b720-4b9fea759061">M</para>
      </td>
    </tr>
    </tbody>
  </table>
  <section label="9.1.1.1.1" status="5" xml:id="sect_9.1.1.1.1">
    <title>Message ID</title>
  
  <para xml:id="para_8dcb383f-4df7-4b8a-a8e6-a35cdd9fc0bc">This parameter identifies the operation. It is used to distinguish this operation from other notifications or operations that the DIMSE Service Provider may have in progress. No two identical values for the Message ID (0000,0110) shall be used for outstanding operations or notifications.</para>
  <note>
    <orderedlist numeration="arabic">
      <listitem>
        <para xml:id="para_e0c9fb9e-25fd-406b-a9b1-713ca5405597">Inclusion of this parameter in the confirmation was permitted in previous versions of this Standard but this mode of use is now retired. This parameter may be included in the confirmation but in such a case the Invoking DIMSE Service User should not attach any semantic significance to this parameter.</para>
      </listitem>
      <listitem>
        <para xml:id="para_4c1d3205-b30b-4733-b808-19eb634063d5">The Message ID (0000,0110) is recommended to be unique within the scope of an Association, to support debug procedures.</para>
      </listitem>
    </orderedlist>
  </note>
  </section>
<section label="9.1.1.1.2" status="5" xml:id="sect_9.1.1.1.2">
    <title>Message ID Being Responded To</title>
  
  <para xml:id="para_aa89812b-812f-4027-8269-5702a727e52b">This parameter specifies the Message ID (0000,0110) of the operation request/indication to which this response/confirmation applies.</para>
  </section>
<section label="9.1.1.1.3" status="5" xml:id="sect_9.1.1.1.3">
    <title>Affected SOP Class UID</title>
  
  <para xml:id="para_a1389c32-7ebc-41cb-96e4-277b57a433f4">For the request/indication, this parameter specifies the SOP Class for the storage. It may be included in the response/confirmation. If included in the response/confirmation, this parameter shall be equal to the value in the request/indication.</para>
  </section>
<section label="9.1.1.1.4" status="5" xml:id="sect_9.1.1.1.4">
    <title>Affected SOP Instance UID</title>
  
  <para xml:id="para_4e8185ac-67f7-4a41-8304-08f1aa565bee">For the request/indication, this parameter specifies the SOP Instance to be stored. It may be included in the response/confirmation. If included in the response/confirmation, this parameter shall be equal to the value in the request/indication.</para>
  </section>
<section label="9.1.1.1.5" status="5" xml:id="sect_9.1.1.1.5">
    <title>Priority</title>
  
  <para xml:id="para_604db541-752f-4207-8612-d013e44144b6">This parameter specifies the priority of the C-STORE operation. It shall be one of LOW, MEDIUM, or HIGH.</para>
  </section>
<section label="9.1.1.1.6" status="5" xml:id="sect_9.1.1.1.6">
    <title>Move Originator Application Entity Title</title>
  
  <para xml:id="para_3d515113-f1a0-46be-a8d1-dbf9d56278b0">This parameter specifies the DICOM AE Title of the DICOM AE that invoked the C-MOVE operation from which this C-STORE sub-operation is being performed.</para>
  </section>
<section label="9.1.1.1.7" status="5" xml:id="sect_9.1.1.1.7">
    <title>Move Originator Message ID</title>
  
  <para xml:id="para_59084a6a-f61a-4e96-815d-c5719a0fa745">This parameter specifies the Message ID (0000,0110) of the C-MOVE request/indication primitive from which this C-STORE sub-operation is being performed.</para>
  </section>
<section label="9.1.1.1.8" status="5" xml:id="sect_9.1.1.1.8">
    <title>Data Set</title>
  
  <para xml:id="para_f570cef7-b8b2-4a1c-8b7a-272884052346">The Data Set accompanying the C-STORE primitive contains the Attributes of the Composite SOP Instance to be stored.</para>
  </section>
<section label="9.1.1.1.9" status="5" xml:id="sect_9.1.1.1.9">
    <title>Status</title>
  
  <para xml:id="para_98793424-a21b-4a97-b815-a440c853491a">This parameter contains the error or success notification for the operation. It shall be included by the Performing DIMSE Service User in the response/confirmation. The following types of status may occur in a response/confirmation (see also <xref linkend="chapter_C" xrefstyle="template:Annex %n"/>):</para>
  <orderedlist numeration="loweralpha">
    <listitem>
      <para xml:id="para_93acf72d-d182-4d55-b80f-d725e50785dc">Refused: Out of resources (Status value is Service Class specific) - This indicates that the Performing DIMSE Service User was unable to store the composite SOP Instance because it was out of resources.</para>
</listitem>
    <listitem>
        <para xml:id="para_1416a945-3d5a-4aac-ba7a-ce3ace5eb943">Refused: SOP Class not supported (0122H) - This indicates that the Performing DIMSE Service User was unable to store the composite SOP Instance because the SOP Class is not supported.</para>
</listitem>
    <listitem>
      <para xml:id="para_6ddd8166-0685-4651-a0bf-41fe6b7afad1">Error: Cannot understand (Status value is Service Class specific) - This indicates that the Performing DIMSE Service User was unable to store the composite SOP Instance because it cannot understand certain Data Elements.</para>
</listitem>
    <listitem>
      <para xml:id="para_dc33a875-cae2-47bb-85be-6b78fc9bf764">Error: Data Set does not match SOP Class (Status value is Service Class specific) - This indicates that the Performing DIMSE Service User was unable to store the composite SOP Instance because the Data Set does not match the SOP Class.</para>
</listitem>
    <listitem>
      <para xml:id="para_a376c585-c35c-49c1-930b-09dc86df386f">Warning (Status value is Service Class specific) - This indicates that the Performing DIMSE Service User was able to store the composite SOP Instance, but detected a probable error.</para>
</listitem>
    <listitem>
<para xml:id="para_eefa62e5-cff0-47ab-838d-5db3c36a6231">Success (0000H) - This indicates that the composite SOP Instance was successfully stored.</para>
</listitem>
    <listitem>
      <para xml:id="para_d1f7dcbf-2bcc-4f38-9f06-66d6cabe54d6">Duplicate invocation (0210H) - This indicates that the Message ID (0000,0110) specified is allocated to another notification or operation.</para>
</listitem>
    <listitem>
      <para xml:id="para_bacadf2e-81fa-4aaa-abdc-640104faf686">Invalid SOP Instance (0117H) - This indicates that the SOP Instance UID specified implied a violation of the UID construction rules.</para>
</listitem>
    <listitem>
      <para xml:id="para_a1b99766-e2a1-492f-8dbc-c8711cc65e37">Mistyped argument (0212H) - This indicates that one of the parameters supplied has not been agreed for use on the Association between the DIMSE Service Users.</para>
</listitem>
    <listitem>
      <para xml:id="para_99679638-34b6-43fd-9759-9ea9c2a5d107">Unrecognized operation (0211H) - This indicates that the operation is not one of those agreed between the DIMSE Service Users.</para>
</listitem>
    <listitem>
      <para xml:id="para_e2068937-12cc-46f6-bfb5-347457b4915f">Refused: Not authorized (0124H) - This indicates that the peer DIMSE Service User was not authorized to store the composite SOP Instance.</para>
</listitem>
  </orderedlist>
</section>
</section>
<section label="9.1.1.2" status="4" xml:id="sect_9.1.1.2">
    <title>C-STORE Service Procedures</title>
  
  <para xml:id="para_f1b8c81a-6aff-4f47-885d-7c2fd8b8937e">The following C-STORE procedures apply:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_ee167a97-851b-4859-b4c5-3be784e6a2b3">The Invoking DIMSE Service User requests that the Performing DIMSE Service User store a composite SOP Instance by issuing a C-STORE Request primitive to the DIMSE Service Provider.</para>
</listitem>
<listitem>
<para xml:id="para_7955778d-b2ff-41fa-97dd-4f8727c5e792">The DIMSE Service Provider issues a C-STORE indication primitive to the Performing DIMSE Service User.</para>
</listitem>
<listitem>
<para xml:id="para_cc6ab7f6-c953-46cf-8976-6a3f247cfca0">The Performing DIMSE Service User reports acceptance or rejection of the C-STORE Request primitive by issuing a C-STORE response primitive to the DIMSE Service Provider,</para>
</listitem>
<listitem>
<para xml:id="para_42ae4879-094a-45c0-8b33-3579c174c8d2">The DIMSE Service Provider issues a C-STORE confirmation primitive to the Invoking DIMSE Service User, completing the C-STORE operation.</para>
</listitem>
</orderedlist>
  <para xml:id="para_3e8e2593-d8f9-41ca-a09a-6812d7d60ee6">The Performing DIMSE Service User may return a C-STORE response primitive with the status of Failed or Refused before the entire C-STORE indication (Data Set) has been completely transmitted by the Invoking DIMSE Service User. A C-STORE response primitive with the status of Success or Warning shall not be returned until the entire C-STORE indication has been received by the Performing DIMSE Service User.</para>
  <note>
    <para xml:id="para_b0a19ff2-5e34-48d5-9aee-142d3b6f7eea">Such an occurrence of a "Failed" response is often called an early failed response.</para>
  </note>
  </section>
</section>
<section label="9.1.2" status="3" xml:id="sect_9.1.2">
    <title>C-FIND Service</title>
  
  <para xml:id="para_9442daac-41a5-4af2-af23-bcb52bf46c5c">The C-FIND service is used by a DIMSE Service User to match a set of Attributes against the Attributes of a set of composite SOP Instances maintained by a peer DIMSE Service User. It is a confirmed service.</para>
  <section label="9.1.2.1" status="4" xml:id="sect_9.1.2.1">
    <title>C-FIND Parameters</title>
  
  <para xml:id="para_d7297d64-882b-4d9f-bf56-445d3e72061b">See <xref linkend="table_9.1-2" xrefstyle="select: label"/>.</para>
    <table frame="box" label="9.1-2" rules="all" xml:id="table_9.1-2">
    <caption>C-FIND Parameters</caption>
    <thead>
      <tr valign="top">
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_a429a676-f1ca-4490-be23-b6e49829a31e">
            <emphasis role="bold">DIMSE-C Parameter Name</emphasis>
          </para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_e015cd10-b8be-4881-aa74-94ed70c1f82e">
            <emphasis role="bold">Req/Ind</emphasis>
          </para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_ad912909-b32d-4132-84fb-7f01fbd847f0">
            <emphasis role="bold">Rsp/Conf</emphasis>
          </para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_8b91810c-b7f7-4952-8fb3-ed63a297a9c2">
            <emphasis role="bold">CnclReq/CnclInd</emphasis>
          </para>
        </td>
      </tr>
      
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c4d5d20a-200a-4b40-b9b9-935b9686ee93">Message ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c6300d55-3d39-429f-b566-6d6341c26891">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6b57a42f-eff0-4ebf-a0b4-030603e2ba6f">U</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4222a75b-a53e-4a39-8ec9-82408b245802">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_03de63e6-ed79-44ba-afa4-20339b48eeaa">Message ID Being Responded To</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9e16fb3c-1ad8-492a-95b0-9dd52bc2af25">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d57a9c99-95a8-416e-9909-4bb263a095a0">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_abcb94be-13da-470f-b1db-ae3ddfaec5fa">M</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6a58d1cc-848d-4df1-8da0-d97a789db5e9">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2f532543-8bd0-46a4-97e4-e3b6b1a7bf1d">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_fa946ae5-c3ae-409c-9e85-79207369fbd0">U(=)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7f1b88ea-e0d7-4934-936c-9ef9f404d659">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_717dc0a7-4167-4747-ba1d-8fb32f9e389c">Priority</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_75381a63-aa03-4f31-ade8-43046be2bea4">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8a62e230-6c40-4ada-8c7d-cbb50425bfc7">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0709601a-88a1-4f47-939b-68d7a4e16489">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_8a609849-e891-4ebb-983b-f5492c85f59b">Identifier</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_cfdf9a62-d5c5-4218-a65f-7e6d22e38e2c">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_befc85ec-f809-4dda-8d5f-16d0d105667f">C</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_44724ec1-272e-4d36-80dc-ad3f7cb96907">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_24e170bd-7f1a-48c9-aa6b-2d204a0501e1">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c1ef5901-7669-4e23-a6a0-5008f6ad35a6">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_67c0b455-a6ba-4f66-be07-a743c467c74b">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ca9edb1c-ff00-4f3b-8466-44af4e28aeed">-</para>
      </td>
    </tr>
    </tbody>
  </table>
  <section label="9.1.2.1.1" status="5" xml:id="sect_9.1.2.1.1">
    <title>Message ID</title>
  
  <para xml:id="para_a542d21a-9269-4a59-b63f-2b92eb38dc98">This parameter identifies the operation. It is used to distinguish this operation from other notifications or operations that the DIMSE Service Provider may have in progress. No two identical values for the Message ID (0000,0110) shall be used for outstanding operations or notifications.</para>
  <note>
    <orderedlist numeration="arabic">
      <listitem>
        <para xml:id="para_18bae427-e085-406d-8aae-02adf343f64f">Inclusion of this parameter in the confirmation was permitted in previous versions of this Standard but this mode of use is now retired. This parameter may be included in the confirmation but in such a case the Invoking DIMSE Service User should not attach any semantic significance to this parameter.</para>
      </listitem>
      <listitem>
        <para xml:id="para_1b84084f-4deb-44e6-9c98-68ec3611565f">The Message ID (0000,0110) is recommended to be unique within the scope of an Association, to support debug procedures.</para>
      </listitem>
    </orderedlist>
  </note>
  </section>
<section label="9.1.2.1.2" status="5" xml:id="sect_9.1.2.1.2">
    <title>Message ID Being Responded To</title>
  
  <para xml:id="para_007e8f6d-4ea4-4c94-b37b-d809e585c390">This parameter specifies the Message ID (0000,0110) of the request/indication to which this response/confirmation applies.</para>
  </section>
<section label="9.1.2.1.3" status="5" xml:id="sect_9.1.2.1.3">
    <title>Affected SOP Class UID</title>
  
  <para xml:id="para_df7d0748-f9b2-400e-9e2f-3f463005830b">For the request/indication, this parameter specifies the SOP Class of the Information Model for the query. It may be included in the response/confirmation. If included in the response/confirmation, this parameter shall be equal to the value in the request/indication.</para>
  </section>
<section label="9.1.2.1.4" status="5" xml:id="sect_9.1.2.1.4">
    <title>Priority</title>
  
  <para xml:id="para_b56e7e01-a96c-4569-8b3d-33aed2a0b74d">This parameter specifies the priority of the C-FIND operation. It shall be one of LOW, MEDIUM, or HIGH.</para>
  </section>
<section label="9.1.2.1.5" status="5" xml:id="sect_9.1.2.1.5">
    <title>Identifier</title>
  <para xml:id="para_1b750584-76b2-42be-b605-3358c5360858">In the request/indication, this is a list of Attributes to be matched against the values of the Attributes in the instances of the composite objects known to the Performing DIMSE Service User.</para>
  <para xml:id="para_ba93d3f7-6fa3-4590-9a54-ca0a527b01af">In the response/confirmation, this is the same list of Attributes with values of these Attributes in a particular composite SOP Instance that matched. It shall be sent only when that Status (0000,0900) is equal to Pending (not permitted for other statuses).</para>
  <para xml:id="para_f19650f6-32f5-4920-bb9f-d8eb394accb2">The list of Attributes and the rules for construction are specified in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>.</para>
</section>
      <section label="9.1.2.1.6" status="5" xml:id="sect_9.1.2.1.6">
          <title>Status</title>
          <para xml:id="para_60f1880e-1091-4e69-b7d0-d4a343e9a4ea">Indicates the status of the response. It may have any of the following values (see also <xref linkend="chapter_C" xrefstyle="template:Annex %n"/>):</para>
          <orderedlist numeration="loweralpha">
              <listitem>
                  <para xml:id="para_d6ff579c-1753-44af-92cb-bc059ded21bb">Success (0000H) - This indicates that processing of the matches is complete. It shall not contain a matching Identifier.</para>
              </listitem>
              <listitem>
                  <para xml:id="para_8850be41-96bd-42b7-8c55-990bc880b5a4">Pending (Status value is Service Class specific) - This indicates that processing of the matches is initiated or continuing. It shall contain a matching Identifier.</para>
              </listitem>
              <listitem>
                  <para xml:id="para_a05b8cfe-0a23-4309-a58c-a5fb37a639f0">Refused: Out of resources (Status value is Service Class specific) - This indicates that processing of the C-FIND operation has been terminated because it was out of resources. This may be the initial response to the C-FIND, or may be sent after a number of pending C-FIND responses. This response shall not contain a matching Identifier.</para>
              </listitem>
              <listitem>
                  <para xml:id="para_1579ffc7-0ec3-4a73-abb2-ff1b6d2fe939">Refused: SOP Class not supported (0122H) - This indicates that processing of the C-FIND operation has been terminated because the SOP Class was not supported. This response shall not contain a matching Identifier.</para>
              </listitem>
              <listitem>
                  <para xml:id="para_43499368-f3cb-44f1-b2bd-cd176d7b6266">Cancel (FE00H) - This indicates that the processing of the C-FIND operation has been terminated due to a C-FIND Cancel Indication primitive. The response shall not contain an Identifier.</para>
              </listitem>
              <listitem>
                  <para xml:id="para_9a20b99a-9bc1-4bda-84c9-79dd62b6cba5">Failed (Status value is Service Class specific) - This indicates that the C-FIND operation failed at the Performing DIMSE Service User.</para>
              </listitem>
              <listitem>
                  <para xml:id="para_01241beb-78f1-46ea-89e6-5e10741796e7">Warning (Status value is Service Class specific) - This indicates that the Performing DIMSE Service User has terminated the C-FIND operation, and the set of returned matching Identifiers may not be complete.</para>
              </listitem>
              <listitem>
                  <para xml:id="para_d7f8a32e-109a-4b8d-83ab-08bcd0807eef">Refused: Not authorized (0124H) - This indicates that the peer DIMSE Service User was not authorized to invoke the C-FIND operation.</para>
              </listitem>
              <listitem>
                  <para xml:id="para_6efba805-e4d1-4efd-b615-680ef2eb52e5">Duplicate invocation (0210H) - This indicates that the Message ID (0000,0110) specified is allocated to another notification or operation.</para>
              </listitem>
              <listitem>
                  <para xml:id="para_ecf9851a-7ea8-4c6a-a9ab-949051e619b2">Unrecognized operation (0211H) - This indicates that the operation is not one of those agreed between the DIMSE Service Users.</para>
              </listitem>
              <listitem>
                  <para xml:id="para_59ef6b44-84da-45db-8b78-a613e8a41803">Mistyped argument (0212H) - This indicates that one of the parameters supplied has not been agreed for use on the Association between the DIMSE Service Users.</para>
              </listitem>     
          </orderedlist>
      </section>
</section>
<section label="9.1.2.2" status="4" xml:id="sect_9.1.2.2">
    <title>C-FIND Service Procedures</title>
  
  <para xml:id="para_d9bacc7a-288c-466e-813d-b422889f772c">The following C-FIND service procedures apply to the invoking DIMSE-service user:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_470300cc-c013-4bc7-a182-b2c7fbb1604f">The Invoking DIMSE Service User requests a Performing DIMSE Service User to match an Identifier against the Attributes of all SOP Instances known to the Performing DIMSE Service User by issuing a C-FIND Request primitive to the DIMSE Service Provider. If the request is rejected by the DIMSE Service Provider, the following procedures do not apply.</para>
</listitem>
<listitem>
<para xml:id="para_85592a1f-9b16-4335-ac02-fefc9bfa4e31">At any time before receiving a C-FIND confirmation primitive with a status unequal to Pending, the Invoking DIMSE Service User may request the Performing DIMSE Service User to cancel the service by issuing a C-FIND Cancel Request primitive to the DIMSE Service Provider.</para>
</listitem>
<listitem>
<para xml:id="para_613b21a0-b156-4000-967e-7d5b087e475d">The Invoking DIMSE Service User receives a C-FIND confirmation primitive for each unique match of the Identifier to a set of composite SOP Instance Attributes.</para>
</listitem>
<listitem>
<para xml:id="para_f256fab3-700e-4d5a-9ccc-afa9b52ec6dd">The Invoking DIMSE Service User receives a final C-FIND confirmation primitive.</para>
</listitem>
</orderedlist>
  <note>
    <para xml:id="para_88ebd7a7-a41c-4cb4-90ae-5bd5a0e44f19">In the above procedures, (c) may precede (b).</para>
  </note>
  <para xml:id="para_8fdd8993-e04f-478d-b9c7-fd57f45e97bf">The following C-FIND service procedures apply to the Performing DIMSE Service User:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_574117a8-b3a2-4b96-833e-8e522db0b16d">When the Performing DIMSE Service User receives a C-FIND indication from the DIMSE Service Provider, it matches the Identifier against the Attributes of known composite SOP Instances.</para>
</listitem>
<listitem>
<para xml:id="para_f7e34f42-51d0-4593-8dcf-730a4f157437">At any time following the C-FIND indication, the Performing DIMSE Service User may receive a C-FIND Cancel Indication.</para>
</listitem>
<listitem>
<para xml:id="para_92133708-bd4a-4aae-b58a-5452d9904a7c">If the C-FIND Cancel Indication is received before the processing of the C-FIND indication has completed, then the C-FIND operation is aborted; otherwise the following procedure does not apply.</para>
</listitem>
<listitem>
<para xml:id="para_e79aee55-7138-4f05-892c-dc02f1d8c862">The Performing DIMSE Service User issues a C-FIND response with a status of Cancel to the DIMSE Service Provider to indicate that the C-FIND operation has been canceled. The following procedures do not apply.</para>
</listitem>
<listitem>
<para xml:id="para_cf45e4ab-f1cf-4420-b2a1-364ba6851896">For each match, the Performing DIMSE Service User issues a C-FIND response with the status set to Pending and a matching Identifier.</para>
</listitem>
<listitem>
    <para xml:id="para_9d955709-5377-4e58-9bb1-d55051b12f54">When the C-FIND operation completes (either in success or in failure), the Performing DIMSE Service User issues a C-FIND response with the status set to either Refused, Failed, Warning, or Success to the DIMSE Service Provider.</para>
</listitem>
</orderedlist>
  <para xml:id="para_c3a574c8-8777-4363-9536-27d7361bc48b">The following C-FIND service procedures apply to the DIMSE Service Provider:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_7c3df0c7-320d-44e1-b4a7-7a1166ebcd93">When the DIMSE Service Provider receives a C-FIND Request primitive from the Invoking DIMSE Service User, it issues a C-FIND indication primitive to the Performing DIMSE Service User.</para>
</listitem>
<listitem>
<para xml:id="para_e8f219ff-61b1-421a-91e0-92d7c4e6ad1e">When the DIMSE Service Provider receives a C-FIND Cancel Request primitive from the Invoking DIMSE Service User, it issues a C-FIND Cancel Indication to the Performing DIMSE Service User.</para>
</listitem>
<listitem>
<para xml:id="para_eed356b7-b4cc-4ca2-bb04-b8f3e8e4a377">When the DIMSE Service Provider receives a C-FIND response primitive from the Performing DIMSE Service User, it issues a C-FIND confirmation primitive to the Invoking DIMSE Service User.</para>
</listitem>
</orderedlist>
  <para xml:id="para_56bd4351-0b9f-4fa5-abd9-0b1b1dcecf4b">The Performing DIMSE Service User may return a C-FIND response primitive with the status of Failed or Refused before the entire C-FIND indication (Data Set) has been completely transmitted by the Invoking DIMSE Service User. A C-FIND response primitive with the status of Success or Warning shall not be returned until the entire C-FIND indication has been received by the Performing DIMSE Service User.</para>
  <note>
    <para xml:id="para_37f54fc5-07d8-4e22-93a2-bd23e12c6d70">Such an occurrence of a "Failed" response is often called an early failed response.</para>
  </note>
  </section>
</section>
<section label="9.1.3" status="3" xml:id="sect_9.1.3">
    <title>C-GET Service</title>
  
  <para xml:id="para_78f008ce-75b0-427c-b17d-35b81243dfc3">The C-GET service is used by a DIMSE Service User to match a set of Attributes against the Attributes of a set of composite SOP Instances maintained by a peer DIMSE Service User, and retrieve all composite SOP Instances that match. It triggers one or more C-STORE sub-operations on the same Association. It is a confirmed service.</para>
  <section label="9.1.3.1" status="4" xml:id="sect_9.1.3.1">
    <title>C-GET Parameters</title>
  
  <para xml:id="para_36823e36-3e81-4a67-92d9-3c74344f0158">See <xref linkend="table_9.1-3" xrefstyle="select: label"/>.</para>
    <table frame="box" label="9.1-3" rules="all" xml:id="table_9.1-3">
    <caption>C-GET Parameters</caption>
    <thead>
      <tr valign="top">
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_021c0580-7be5-441d-97a8-26563c3560e8">
            <emphasis role="bold">DIMSE-C Parameter Name</emphasis>
          </para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_05a8eec7-2c4b-4d1e-9d8f-ccd956ca03d1">
            <emphasis role="bold">Req/Ind</emphasis>
          </para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_47e055c0-9b24-430c-b926-54b4fa0a7745">
            <emphasis role="bold">Rsp/Conf</emphasis>
          </para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_854dd306-d844-4e74-b9d3-9b0f60e439b1">
            <emphasis role="bold">CnclReq/CnclInd</emphasis>
          </para>
        </td>
      </tr>
      
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_25d10051-fd5c-401f-8296-7bce9474682f">Message ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_de1a4255-452d-459c-ba7a-b31e5f901e85">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c8d1ad64-2ada-4822-8baf-3b2b9ee1a373">U</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c00cb904-e3ac-4c42-adc5-fe09e6b3eb35">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_93da989d-75c6-4510-9827-1fc8be0614f1">Message ID Being Responded To</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_27d10862-6614-4529-a3c5-a00739910bdd">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ac133e54-4811-4372-a9fe-1b1718b780c4">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4cba9245-717a-42b3-bcd0-7a386aa227eb">M</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_bbf2f1b8-e014-472d-a1d2-9d3ae83cdf31">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2e94bf67-0564-49df-a6fe-95180e30915e">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e49b62d9-38c1-478c-9ea7-0e37ebbacd8b">U(=)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ce76d59e-4cb4-4fb8-8896-3aba3d5439c3">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3e1210ce-3cb3-4f25-8fd9-39c4e20ce57c">Priority</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e9f43396-9727-4718-9b39-d821ca6ca2fd">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e7fca062-85a3-412f-85f5-0175843eac87">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_10d8bc9a-39d9-44ac-bd99-1a00529e0d17">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c0c0dd4e-c936-4081-8100-680e08c2da30">Identifier</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5eefb6f0-7be8-44bf-ace9-49744a084578">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7c5a9582-e2a8-489b-9970-2e8969aa099f">U</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ae57cfc5-4787-4281-b139-e84b2eff2c4e">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3ded8327-739e-4348-a471-0b5d0afa726b">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2e0a4329-30ae-47b2-8f86-6e8cd3afd1f5">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5611c59e-59f9-462f-b6e3-1dec91a019fa">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c5ffec36-663f-4eee-88d7-43a0484d90d4">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_18fc03ea-b71f-4709-a50b-a4b0dbcb30e9">Number of Remaining Sub-operations</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9cf1eaf6-d564-4b0f-b9b7-62dee7d7722b">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7b2efcb9-7387-4de7-896d-f8a2ffb784b7">C</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f92a2231-fd9d-4d84-9020-55dbeba59fb8">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_ad332490-3edb-46ef-802e-2b2a8652a702">Number of Completed Sub-operations</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b9a1bf67-0ab2-4fac-af6b-61a19739d049">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2a75bd91-c834-4288-b83f-dc819bfbcb25">C</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5c745ec6-b8b6-4ec6-a745-11e0fbe793f2">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_53b94613-be0a-4203-bc54-d80275d0b63b">Number of Failed Sub-operations</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f978243d-d1b9-40ed-b2e1-2054a30b09a9">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5c771981-d9b3-494d-bd81-987ce546c532">C</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8eff86fd-0d3a-432d-b766-468f2720cb68">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_8c82a38f-2520-4efa-967d-7599e383b467">Number of Warning Sub-operations</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_acf3d121-f066-4d56-b430-0837b2f4400f">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_38fd86dc-c0a6-40b9-af56-74c7395fcb0b">C</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1f235fdb-64a4-4d3a-b7de-8cbf7da0a4ab">-</para>
      </td>
    </tr>
    </tbody>
  </table>
  <section label="9.1.3.1.1" status="5" xml:id="sect_9.1.3.1.1">
    <title>Message ID</title>
  
  <para xml:id="para_06c50a4d-5398-4e65-a92a-b4a9c3f11cb7">This parameter identifies the operation. It is used to distinguish this operation from other notifications or operations that the DIMSE Service Provider may have in progress. No two identical values for the Message ID (0000,0110) shall be used for outstanding operations or notifications.</para>
  <note>
    <orderedlist numeration="arabic">
      <listitem>
        <para xml:id="para_0e87916d-c0c6-4d21-a254-44b807f33a39">Inclusion of this parameter in the confirmation was permitted in previous versions of this Standard but this mode of use is now retired. This parameter may be included in the confirmation but in such a case the Invoking DIMSE Service User should not attach any semantic significance to this parameter.</para>
      </listitem>
      <listitem>
        <para xml:id="para_7c63ee63-7951-40ea-a968-5dd395341044">The Message ID (0000,0110) is recommended to be unique within the scope of an Association, to support debug procedures.</para>
      </listitem>
    </orderedlist>
  </note>
  </section>
<section label="9.1.3.1.2" status="5" xml:id="sect_9.1.3.1.2">
    <title>Message ID Being Responded To</title>
  
  <para xml:id="para_876bf84a-a351-41d7-b79b-e92d00139c51">This parameter specifies the Message ID (0000,0110) of the request/indication to which this response/confirmation applies.</para>
  </section>
<section label="9.1.3.1.3" status="5" xml:id="sect_9.1.3.1.3">
    <title>Affected SOP Class UID</title>
  
  <para xml:id="para_ec5439ab-72c3-401b-b3e9-9a4fd3dae29a">For the request/indication, this parameter specifies the SOP Class of the Information Model for the retrieve. It may be included in the response/confirmation. If included in the response/confirmation, this parameter shall be equal to the value in the request/indication.</para>
  </section>
<section label="9.1.3.1.4" status="5" xml:id="sect_9.1.3.1.4">
    <title>Priority</title>
  
  <para xml:id="para_a9ae1faa-9a69-4e40-b27d-aeda57e56ea3">This parameter specifies the priority of the C-GET operation. It shall be one of LOW, MEDIUM or HIGH. This priority shall also be the priority used for all sub-operations.</para>
  </section>
<section label="9.1.3.1.5" status="5" xml:id="sect_9.1.3.1.5">
    <title>Identifier</title>
  
  <para xml:id="para_a548a304-f25b-4863-8e4c-92df79fbbcf5">In the request/indication, this is a list of Attributes to be matched against the values of the Attributes of known composite SOP Instances of the Performing DIMSE Service User. The list of Attributes allowed and the rules for the construction are specified in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>.</para>
  <note>
    <para xml:id="para_05ba2762-24f6-4876-99d8-9ffd4887d375">The Identifier is specified as U in the Response/Confirmation, but Services defined in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/> that use this primitive may impose mandatory or conditional requirements on its presence.</para>
  </note>
  <para xml:id="para_fa79fb3a-45f4-4327-9a20-0b1e23ca1d96">In the response/confirmation, this is a list of Attributes that provide status information about the C-GET operation. The list of Attributes allowed and the rules that define the usage of the Identifier are specified in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>.</para>
  </section>
<section label="9.1.3.1.6" status="5" xml:id="sect_9.1.3.1.6">
    <title>Status</title>
  <para xml:id="para_e5ad28f0-62a5-4cc8-a934-a2b662e80e71">Indicates the status of the response. It may have any of the following values (see also <xref linkend="chapter_C" xrefstyle="template:Annex %n"/>):</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_dfd9b94b-f8dc-4824-a455-d1b9ca6732c6">Success (0000H) - This indicates that processing of the matches and all sub-operations are complete.</para>
</listitem>
<listitem>
  <para xml:id="para_69f09355-8e78-4f62-8d63-9039d529857b">Pending (Status value is Service Class specific) - This indicates that processing of the matches and sub-operations is initiated or continuing.</para>
</listitem>
<listitem>
  <para xml:id="para_68c10ed1-de9e-484c-be20-4504e2568bfd">Refused: Out of resources (Status value is Service Class specific) - This indicates that processing of the C-GET operation has been terminated because it was out of resources. This may be the initial response to the C-GET request or may be sent after a number of Pending statuses.</para>
</listitem>
<listitem>
  <para xml:id="para_57aa15b9-133c-494a-b46d-47a2b6a0c5fb">Refused: SOP Class not supported (0122H) - This indicates that processing of the C-GET operation has been terminated because the SOP Class was not supported.</para>
</listitem>
<listitem>
  <para xml:id="para_54b84554-c8b7-4c68-afd3-80dc23b79bed">Cancel (FE00H) - This indicates that processing of the C-GET operation has been terminated due to a C-GET Cancel indication primitive.</para>
</listitem>
<listitem>
  <para xml:id="para_d9670778-ee08-44c8-b8dd-5d285e6c271c">Failed (Status value is Service Class specific) - This indicates that the C-GET operation failed at the Performing DIMSE Service User.</para>
</listitem>
<listitem>
  <para xml:id="para_4309e45c-2baf-4fbf-baf0-7dd808f8194e">Duplicate invocation (0210H) - This indicates that the Message ID (0000,0110) specified is allocated to another notification or operation.</para>
</listitem>
<listitem>
  <para xml:id="para_74a4c4f3-28c4-4018-980b-83fa3e247db9">Mistyped argument (0212H) - This indicates that one of the parameters supplied has not been agreed for use on the Association between the DIMSE Service Users.</para>
</listitem>
<listitem>
  <para xml:id="para_46a99c07-6782-456a-99ce-adbdba467778">Unrecognized operation (0211H) - This indicates that the operation is not one of those agreed between the DIMSE Service Users.</para>
</listitem>
<listitem>
    <para xml:id="para_960782bd-f9f4-4d1f-a047-d479a890ca94">Refused: Not authorized (0124H) - This indicates that the peer DIMSE Service User was not authorized to invoke the C-GET operation.</para>
</listitem>
    <listitem>
      <para xml:id="para_32b6e760-0652-40f1-8b97-5d8cf8dcfd56">Warning (Status value is Service Class specific) - This indicates that the Performing DIMSE Service User was able to perform sub-operations but detected a probable error with one or more of them.</para>
    </listitem>
</orderedlist>
  </section>
<section label="9.1.3.1.7" status="5" xml:id="sect_9.1.3.1.7">
    <title>Number of Remaining Sub-Operations</title>
  
  <para xml:id="para_ae9f5369-523d-4a42-b0b5-7f62623ff8ba">This specifies the number of remaining C-STORE sub-operations to be invoked by this C-GET operation. It may be included in any response/confirmation and shall be included if the status is equal to Pending.</para>
  </section>
<section label="9.1.3.1.8" status="5" xml:id="sect_9.1.3.1.8">
    <title>Number of Completed Sub-Operations</title>
  
  <para xml:id="para_fd2f0b72-8cb0-4848-bf30-31459af469bb">This specifies the number of C-STORE sub-operations invoked by this C-GET operation that have completed successfully. It may be included in any response/confirmation and shall be included if the status is equal to Pending.</para>
  </section>
<section label="9.1.3.1.9" status="5" xml:id="sect_9.1.3.1.9">
    <title>Number of Failed Sub-Operations</title>
  
  <para xml:id="para_5aa62307-88e8-4dea-8de6-62d063ef349a">This specifies the number of C-STORE sub-operations invoked by this C-GET operation that have failed. It may be included in any response/confirmation and shall be included if the status is equal to Pending.</para>
  </section>
<section label="9.1.3.1.10" status="5" xml:id="sect_9.1.3.1.10">
    <title>Number of Warning Sub-Operations</title>
  
  <para xml:id="para_d3615dae-7ba1-46e5-8473-084a58f6595e">This specifies the number of C-STORE sub-operation invoked by this C-GET operation that generated Warning responses. It may be included in any response/confirmation and shall be included if the status is equal to Pending.</para>
  </section>
</section>
<section label="9.1.3.2" status="4" xml:id="sect_9.1.3.2">
    <title>C-GET Service Procedures</title>
  
  <para xml:id="para_d1c0016f-6152-4919-9283-7b81f0e24ec5">The following C-GET service procedures apply to the invoking DIMSE-service user:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_10857fd7-48b6-4994-8aa8-4320d23557c1">The Invoking DIMSE Service User requests a Performing DIMSE Service User to match an Identifier against the Attributes of all SOP Instances known to the Performing DIMSE Service User and generate a C-STORE sub-operation for each match. This request is made by issuing a C-GET Request primitive to the DIMSE Service Provider. If the request is rejected by the DIMSE Service Provider, the following procedures do not apply.</para>
</listitem>
<listitem>
<para xml:id="para_0c5c480c-daf4-4f36-b255-8b56eba18abf">At any time before receiving a C-GET confirmation primitive with status unequal to Pending, the Invoking DIMSE Service User may request the Performing DIMSE Service User to cancel the service by issuing a C-GET Cancel Request primitive to the DIMSE Service Provider.</para>
</listitem>
<listitem>
<para xml:id="para_0dcda153-f567-4e21-a826-0e41389bbc04">The Invoking DIMSE Service User may receive C-GET confirmation primitives with status of Pending during the processing of the C-GET operation.</para>
</listitem>
<listitem>
<para xml:id="para_af3734c6-aa9d-4c46-9b8f-bcbbd69c1591">The Invoking DIMSE Service User receives a final C-GET confirmation primitive.</para>
</listitem>
</orderedlist>
  <note>
    <para xml:id="para_62e47045-234e-4c59-90f2-a9f4d40eebef">In the above procedures, (c) may precede (b).</para>
  </note>
  <para xml:id="para_ec0b65fc-c3f5-42ef-829b-435faa297991">The following C-GET service procedures apply to the Performing DIMSE Service User:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_c2f516c5-b320-4dbc-adc5-1168ca7eaba1">When the Performing DIMSE Service User receives a C-GET indication from the DIMSE Service Provider it matches the Identifier against the Attributes of known composite SOP Instances and generates a C-STORE sub-operation for each match.</para>
</listitem>
<listitem>
<para xml:id="para_9073dfb0-841b-4e69-bd71-3387f672f5a7">At any time following the C-GET indication, the Performing DIMSE Service User may receive a C-GET Cancel indication.</para>
</listitem>
<listitem>
<para xml:id="para_ff1ab614-d8b5-4318-864c-f0fcdc7bc97a">If the C-GET Cancel indication is received before the processing of the C-GET indication has completed, then the C-GET operation is terminated; otherwise the following procedure does not apply.</para>
</listitem>
<listitem>
<para xml:id="para_675ec671-e5bd-47ed-8b1c-dead1119376c">The Performing DIMSE Service User issues a C-GET response with a status of Cancel to the DIMSE Service Provider to indicate that the C-GET operation has been canceled. The following procedures do not apply.</para>
</listitem>
<listitem>
<para xml:id="para_7117d8c7-9651-4589-92e9-9b4c18c24814">For each match, the Performing DIMSE Service User initiates a C-STORE sub-operation on the same Association as the C-GET. In this sub-operation, the C-GET Performing DIMSE Service User becomes the C-STORE Invoking DIMSE Service User. The C-STORE Performing DIMSE Service User is the C-GET Invoking DIMSE Service User.</para>
</listitem>
<listitem>
<para xml:id="para_18e8fe8f-df3a-401d-b944-2dd141f67252">During the processing of the C-GET operation, the Performing DIMSE Service User may issue C-GET response primitives with a status of Pending.</para>
</listitem>
<listitem>
<para xml:id="para_1a873f1c-59c5-4432-a505-957956d57116">When the C-GET operation completes (either in success or in failure), the Performing DIMSE Service User issues a C-GET response with the status set to either refused, failed or success to the DIMSE Service Provider.</para>
</listitem>
</orderedlist>
  <para xml:id="para_94636c71-b221-4592-88c5-6b5a55106be3">The following C-GET service procedures apply to the DIMSE Service Provider:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_b10ecd8b-58e0-48dc-a858-9e6d29d4fea6">When the DIMSE Service Provider receives a C-GET Request primitive from the Invoking DIMSE Service User, it issues a C-GET indication primitive to the Performing DIMSE Service User.</para>
</listitem>
<listitem>
<para xml:id="para_c52de732-f548-420c-962d-69912e82a739">When the DIMSE Service Provider receives a C-GET Cancel Request primitive from the Invoking DIMSE Service User, it issues a C-GET Cancel indication to the Performing DIMSE Service User.</para>
</listitem>
<listitem>
<para xml:id="para_ee426b52-0a44-4a10-aef2-0143f29014d2">When the DIMSE Service Provider receives a C-GET response primitive from the Performing DIMSE Service User, it issues a C-GET confirmation primitive to the Invoking DIMSE Service User.</para>
</listitem>
</orderedlist>
  <para xml:id="para_7095ebe9-0129-4630-b3c1-1a2448430272">The Performing DIMSE Service User may return a C-GET response primitive with the status of Failed or Refused before the entire C-GET indication (Data Set) has been completely transmitted by the Invoking DIMSE Service User. A C-GET response primitive with the status of Success or Warning shall not be returned until the entire C-GET indication has been received by the Performing DIMSE Service User.</para>
  <note>
    <para xml:id="para_e4f7e9e6-4a1d-4c1f-a87c-2c94c210610b">Such an occurrence of a "Failed" response is often called an early failed response.</para>
  </note>
  </section>
</section>
<section label="9.1.4" status="3" xml:id="sect_9.1.4">
    <title>C-MOVE Service</title>
  
  <para xml:id="para_1a4f4114-03ce-4ec8-a721-01426a6bc988">The C-MOVE service is used by a DIMSE Service User to match a set of Attributes against the Attributes of a set of composite SOP Instances maintained by a peer DIMSE Service User, and retrieve all composite SOP Instances that match. It triggers one or more C-STORE sub-operations on a separate Association. It is a confirmed service.</para>
  <section label="9.1.4.1" status="4" xml:id="sect_9.1.4.1">
    <title>C-MOVE Parameters</title>
  
  <para xml:id="para_78202e41-fb7e-4b70-8153-1a5c02305ed3">See <xref linkend="table_9.1-4" xrefstyle="select: label"/>.</para>
    <table frame="box" label="9.1-4" rules="all" xml:id="table_9.1-4">
    <caption>C-MOVE Parameters</caption>
    <thead>
      <tr valign="top">
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_0bbebae2-4821-4109-aac1-1523c19e5a0d">
            <emphasis role="bold">DIMSE-C Parameter Name</emphasis>
          </para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_6d3ec145-3527-4962-8625-384b1ab19e17">
            <emphasis role="bold">Req/Ind</emphasis>
          </para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_caad6e0f-b767-4c58-a46a-ea49102af268">
            <emphasis role="bold">Rsp/Conf</emphasis>
          </para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_52ff38b7-863a-40e8-a41e-df2361cebc1f">
            <emphasis role="bold">CnclReq/CnclInd</emphasis>
          </para>
        </td>
      </tr>
      
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a6186fe6-b1ab-4038-9d73-f2658d624799">Message ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ad212e16-0e26-4a49-aeae-5a0336198ed5">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4ee0902c-5c08-478c-a02e-b00da8c5efbb">U</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_bb57de83-2f76-4d59-8f2b-821967c7b209">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f2b6a0bb-9467-47c4-b8c9-1921b9319243">Message ID Being Responded To</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ac505f67-768a-45b2-97fb-72bea4d18e60">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_365e958b-54b2-4c5e-8065-b82698e936c1">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6ea3e27b-c4a4-490a-8805-83a9a1461ce7">M</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1ae21d44-1340-4716-84b1-027de02def11">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_22791bf8-225f-4117-ad23-25c56e79b38c">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_65093532-40ba-42b1-b68e-08ab257111a3">U(=)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ac36e7b4-d919-45c6-a9be-a59b1e60c070">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a6f6fe7a-8f85-4f26-abac-09159465994a">Priority</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_bbeba7f8-ff0e-4ed5-ab58-8d87f8469931">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e355073d-20e7-4425-b906-637b9139fbf0">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0b48f141-6422-4b78-bd39-a4ed8af0fba0">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_7153ce8c-37fb-4a2e-ac05-929933b8fde8">Move Destination</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6b9c0dbf-cf77-488d-9ea1-569cda571f89">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_df46e5f3-9fdf-4874-a295-bdfac090b2b2">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7e68dede-bd68-4813-bbaa-964d2cb7c71a">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_192036c5-65a4-46f4-85fb-6c9eb6e41469">Identifier</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_115408f0-0058-4faa-b08a-dabf7651d2d7">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a0ee7545-4cb3-4bb7-a3a0-9fa0016f9b35">U</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b5386c1b-59f9-4e63-a4a4-7f0a3643f84e">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_83d72249-b2b0-4300-8985-628b6b9ee0be">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e52d2be0-640e-40e1-9af4-77cf24042e87">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_3c0ec8f6-7edd-428b-b26b-b0da4cef7b4a">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_bb2d14c8-395d-407f-9b22-8460eea97115">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6dfa5bc5-7f2e-4c5d-94ea-8a9254ee093d">Number of Remaining Sub-operations</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e7c035f7-c60a-40fb-ac33-4c451091da25">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_bfbd7978-951e-40b1-9d5f-671d45b6260f">C</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_64ba6dff-1b64-471d-b5e2-a043f1a36ecb">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_60290fa7-c8ad-4266-a84f-0ab406e56a83">Number of Completed Sub-operations</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4c4924a0-150b-4d3a-abc6-c7a2cb91ba53">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b2ce3b72-4e20-42ae-bca3-13a0bc291173">C</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_931199a8-50fc-4528-abd5-7f74d52d36a3">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_645542f9-b436-4b72-9c18-40256ee6be4d">Number of Failed Sub-operations</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8802a3df-d8c7-40ca-a551-40a5f428df0a">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f50cc85b-7a1d-408c-9a4d-b08571407077">C</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_41eadf76-2be8-4850-96f8-17a1bf5d7fcd">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3db54430-6c1a-4375-841d-a08e2a0f362d">Number of Warning Sub-operations</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c9c02926-976d-4655-a338-3a174aa76a08">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f791d12e-e474-4518-b02c-27d66799f921">C</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c8426494-6242-4673-bc71-528b5fff6b35">-</para>
      </td>
    </tr>
    </tbody>
  </table>
  <section label="9.1.4.1.1" status="5" xml:id="sect_9.1.4.1.1">
    <title>Message ID</title>
  
  <para xml:id="para_0188002d-119c-429d-921a-a1e76fa8b642">This parameter identifies the operation. It is used to distinguish this operation from other notifications or operations that the DIMSE Service Provider may have in progress. No two identical values for the Message ID (0000,0110) shall be used for outstanding operations or notifications.</para>
  <note>
    <orderedlist numeration="arabic">
      <listitem>
        <para xml:id="para_d0e5a233-805e-4787-9cb2-7ba5e6d6d2e0">Inclusion of this parameter in the confirmation was permitted in previous versions of this Standard but this mode of use is now retired. This parameter may be included in the confirmation but in such a case the Invoking DIMSE Service User should not attach any semantic significance to this parameter.</para>
      </listitem>
      <listitem>
        <para xml:id="para_4eb62f03-1cd2-44df-9c47-79a346029030">The Message ID (0000,0110) is recommended to be unique within the scope of an Association, to support debug procedures.</para>
      </listitem>
    </orderedlist>
  </note>
  </section>
<section label="9.1.4.1.2" status="5" xml:id="sect_9.1.4.1.2">
    <title>Message ID Being Responded To</title>
  
  <para xml:id="para_b80d1a56-f65b-4833-9e5e-1b6200b9e8a0">This parameter specifies the Message ID (0000,0110) of the request/indication to which this response/confirmation applies.</para>
  </section>
<section label="9.1.4.1.3" status="5" xml:id="sect_9.1.4.1.3">
    <title>Affected SOP Class UID</title>
  
  <para xml:id="para_50236b8a-237d-49a9-ae10-4beb0dacaec1">For the request/indication, this parameter specifies the SOP Class of the Information Model for the retrieve. It may be included in the response/confirmation. If included in the response/confirmation, this parameter shall be equal to the value in the request/indication.</para>
  </section>
<section label="9.1.4.1.4" status="5" xml:id="sect_9.1.4.1.4">
    <title>Priority</title>
  
  <para xml:id="para_8d276e50-81eb-4ebd-90de-c145121eba9e">This parameter specifies the priority of the C-MOVE operation. It shall be one of LOW, MEDIUM or HIGH . This priority shall also be the priority used for all sub-operations.</para>
  </section>
<section label="9.1.4.1.5" status="5" xml:id="sect_9.1.4.1.5">
    <title>Move Destination</title>
  
  <para xml:id="para_c1b0a7cf-4ebe-474c-b9a9-9b1c74009ea9">This parameter specifies the DICOM AE Title of the destination DICOM AE to which the C-STORE sub-operations are being performed.</para>
  </section>
<section label="9.1.4.1.6" status="5" xml:id="sect_9.1.4.1.6">
    <title>Identifier</title>
  
  <para xml:id="para_f0b1dcd0-cb63-488d-b388-da0edf0de3ec">In the request/indication, this is a list of Attributes to be matched against the values of the Attributes of known composite SOP Instances of the Performing DIMSE Service User. The list of Attributes allowed and the rules for the construction are in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>.</para>
  <note>
    <para xml:id="para_1432f465-1c70-4dd7-ad22-33ff438ad70f">The Identifier is specified as U in the Response/Confirmation, but Services defined in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/> that use this primitive may impose mandatory or conditional requirements on its presence.</para>
  </note>
  <para xml:id="para_caf64ee9-3089-40c1-99ec-297ab699c689">In the response/confirmation, this is a list of Attributes that provide status information about the C-MOVE operation. The list of Attributes allowed and the rules that define the usage of the Identifier are specified in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>.</para>
  </section>
<section label="9.1.4.1.7" status="5" xml:id="sect_9.1.4.1.7">
    <title>Status</title>
  <para xml:id="para_3167dc22-d371-40b1-88fc-662a1ff197a7">Indicates the status of the response. It may have any of the following values (see also <xref linkend="chapter_C" xrefstyle="template:Annex %n"/>):</para>
  <orderedlist numeration="loweralpha">
<listitem>
  <para xml:id="para_0e204a8a-fc83-4c6a-a1aa-e9363bbec73b">Success (0000H) - This indicates that processing of the matches and all sub-operations are complete.</para>
</listitem>
<listitem>
  <para xml:id="para_7edfbf9d-cbf7-4a20-86be-b9c19f11e20d">Pending (Status value is Service Class specific) - This indicates that procession of the matches and sub-operations is initiated or continuing.</para>
</listitem>
<listitem>
  <para xml:id="para_cfe66527-6476-4e3c-bb5f-0dde5ec2bfcd">Refused: Out of resources (Status value is Service Class specific) - This indicates that processing of the C-MOVE operation has been terminated because it was out of resources. This may be the initial response to the C-MOVE or may be sent after a number of Pending statuses.</para>
</listitem>
<listitem>
  <para xml:id="para_a539ad29-f10f-407e-9ba8-18bbb5d808f4">Refused: SOP Class not supported (0122H) - This indicates that processing of the C-MOVE operation has been terminated because the SOP Class was not supported.</para>
</listitem>
<listitem>
  <para xml:id="para_c7ccff60-ca2d-496c-b7c6-d442401adf97">Refused: Move Destination unknown (Status value is Service Class specific) - This indicates that processing of the C-MOVE operation has been terminated because the Move Destination was unknown.</para>
</listitem>
<listitem>
  <para xml:id="para_5d3d21ab-5466-43dc-80de-9b888f928594">Cancel (FE00H) - This indicates that processing of the C-MOVE operation has been terminated due to a C-MOVE Cancel indication primitive.</para>
</listitem>
<listitem>
  <para xml:id="para_7737dbe2-f7a1-40e0-89a1-164c4a417f06">Failed (Status value is Service Class specific) - This indicates that the C-MOVE operation failed at the Performing DIMSE Service User.</para>
</listitem>
<listitem>
  <para xml:id="para_147d02b7-b271-4783-89ae-a5349ee2b7ac">Duplicate invocation (0210H) - This indicates that the Message ID (0000,0110) specified is allocated to another notification or operation.</para>
</listitem>
<listitem>
  <para xml:id="para_b54110d0-1154-4026-b0fb-0eb0b940e05e">Mistyped argument (0212H) - This indicates that one of the parameters supplied has not been agreed for use on the Association between the DIMSE Service Users.</para>
</listitem>
<listitem>
  <para xml:id="para_893c6c5d-f4fb-4c32-b51b-7b89be2bfef8">Unrecognized operation (0211H) - This indicates that the operation is not one of those agreed between the DIMSE Service Users.</para>
</listitem>
<listitem>
  <para xml:id="para_7b3eb0f7-e411-464e-ad20-b57618467419">Refused: Not authorized (0124H) - This indicates that the peer DIMSE Service User was not authorized to invoke the C-MOVE operation.</para>
</listitem>
    <listitem>
      <para xml:id="para_f72fbcac-98b7-4181-9436-70f7713ecad2">Warning (Status value is Service Class specific) - This indicates that the Performing DIMSE Service User was able to perform sub-operations but detected a probable error with one or more of them.</para>
    </listitem>
</orderedlist>
  </section>
<section label="9.1.4.1.8" status="5" xml:id="sect_9.1.4.1.8">
    <title>Number of Remaining Sub-Operations</title>
  
  <para xml:id="para_351c78d3-9c6e-48c6-9865-dc449dad1a76">This specifies the number of remaining C-STORE sub-operations to be invoked by this C-MOVE operation. It may be included in any response/confirmation and shall be included if the status is equal to Pending.</para>
  </section>
<section label="9.1.4.1.9" status="5" xml:id="sect_9.1.4.1.9">
    <title>Number of Completed Sub-Operations</title>
  
  <para xml:id="para_774dc96f-e29e-4cb7-a71e-d97ada548331">This specifies the number of C-STORE sub-operations invoked by this C-MOVE operation that have completed successfully. It may be included in any response/confirmation and shall be included if the status is equal to Pending.</para>
  </section>
<section label="9.1.4.1.10" status="5" xml:id="sect_9.1.4.1.10">
    <title>Number of Failed Sub-Operations</title>
  
  <para xml:id="para_3a1ac073-9e55-4c31-a9d7-6c0b4d5ef797">This specifies the number of C-STORE sub-operations invoked by this C-MOVE operation that have failed. It may be included in any response/confirmation and shall be included if the status is equal to Pending.</para>
  </section>
<section label="9.1.4.1.11" status="5" xml:id="sect_9.1.4.1.11">
    <title>Number of Warning Sub-Operations</title>
  
  <para xml:id="para_f3e65ce9-d76c-4a5c-84e6-61c491896a59">This specifies the number of C-STORE sub-operations invoked by this C-MOVE operation that generated Warning responses. It may be included in any response/confirmation and shall be included if the status is equal to Pending.</para>
  </section>
</section>
<section label="9.1.4.2" status="4" xml:id="sect_9.1.4.2">
    <title>C-MOVE Service Procedures</title>
  
  <para xml:id="para_a946e5da-781f-4cb3-934f-52b48ce89e96">The following C-MOVE service procedures apply to the invoking DIMSE-service user:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_da52177f-39f7-47f1-a34a-3d6ef7cabcfe">The Invoking DIMSE Service User requests a Performing DIMSE Service User to match an Identifier against the Attributes of all SOP Instances known to the Performing DIMSE Service User and generate a C-STORE sub-operation for each match. This request is made by issuing a C-MOVE Request primitive to the DIMSE Service Provider. If the request is rejected by the DIMSE Service Provider, the following procedures do not apply.</para>
</listitem>
<listitem>
<para xml:id="para_ce6ed009-2a6e-484e-8838-7e372a40e8a5">At any time before receiving a C-MOVE confirmation primitive with status unequal to Pending, the Invoking DIMSE Service User may request the Performing DIMSE Service User to cancel the service by issuing a C-MOVE Cancel Request primitive to the DIMSE Service Provider.</para>
</listitem>
<listitem>
<para xml:id="para_0bd38dc7-30d3-42e6-8b75-fa98ff05d932">The Invoking DIMSE Service User may receive C-MOVE confirmation primitives with status of Pending during the processing of the C-MOVE operation.</para>
</listitem>
<listitem>
<para xml:id="para_a187ed92-78db-4404-967d-33a8dab1ddb3">The Invoking DIMSE Service User receives a final C-MOVE confirmation primitive.</para>
</listitem>
</orderedlist>
  <note>
    <para xml:id="para_4447f046-e943-447c-a8ff-92c0b0ae95c4">in the above procedures, (c) may precede (b).</para>
  </note>
  <para xml:id="para_5411107b-57d7-44b5-86c4-226227b95629">The following C-MOVE service procedures apply to the Performing DIMSE Service User:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_c87846a8-2921-4357-9cdb-e6c4c70333ff">When the Performing DIMSE Service User receives a C-MOVE indication from the DIMSE Service Provider it matches the Identifier against the Attributes of known composite SOP Instances and generates a C-STORE sub-operation for each match.</para>
</listitem>
<listitem>
<para xml:id="para_b8ecf526-6cc4-4a92-a890-1c74784a041a">At any time following the C-MOVE indication, the Performing DIMSE Service User may receive a C-MOVE Cancel indication.</para>
</listitem>
<listitem>
<para xml:id="para_ea486470-bf58-4177-ada2-8a73d8ded2c2">If the C-MOVE Cancel indication is received before the processing of the C-MOVE request has completed, then the C-MOVE operation is terminated; otherwise the following procedure does not apply.</para>
</listitem>
<listitem>
<para xml:id="para_be646ff8-45e5-4211-a30a-93519b7c1bd3">The Performing DIMSE Service User issues a C-MOVE response with a status of Cancel to the DIMSE Service Provider to indicate that the C-MOVE operation has been canceled. The following procedures do not apply.</para>
</listitem>
<listitem>
<para xml:id="para_76c08a27-70c9-4681-8048-c254d8326185">For each matching composite SOP Instance, the C-MOVE Performing DIMSE Service User initiates a C-STORE sub-operation on a different Association than the C-MOVE. In this sub-operation, the C-MOVE Performing DIMSE Service User becomes the C-STORE Invoking DIMSE Service User. The C-STORE Performing DIMSE Service User may or may not be the C-MOVE Invoking DIMSE Service User.</para>
</listitem>
<listitem>
<para xml:id="para_cf66ae2f-a0d1-47c9-b599-826ba95999bb">During the processing of the C-MOVE operation, the Performing DIMSE Service User may issue C-MOVE response primitives with a status of Pending.</para>
</listitem>
<listitem>
<para xml:id="para_f0647c24-5dda-4147-8ac6-29afb96f9e23">When the C-MOVE operation completes (either in success or in failure), the Performing DIMSE Service User issues a C-MOVE response with the status set to either Refused, Failed, or Success to the DIMSE Service Provider.</para>
</listitem>
</orderedlist>
  <para xml:id="para_6de71181-1e81-4638-b4e1-b4a879ee81a9">The following C-MOVE service procedures apply to the DIMSE Service Provider:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_9e84d352-78d3-4e6f-97bb-dbad7896beb3">When the DIMSE Service Provider receives a C-MOVE Request primitive from the Invoking DIMSE Service User, it issues a C-MOVE indication primitive to the Performing DIMSE Service User.</para>
</listitem>
<listitem>
<para xml:id="para_f8ec6560-678c-4674-afd5-7fe362057526">When the DIMSE Service Provider receives a C-MOVE Cancel Request primitive from the Invoking DIMSE Service User, it issues a C-MOVE Cancel indication to the Performing DIMSE Service User.</para>
</listitem>
<listitem>
<para xml:id="para_eb3e974b-f8e9-4f34-a5a4-4b809b1d232d">When the DIMSE Service Provider receives a C-MOVE response primitive from the Performing DIMSE Service User, it issues a C-MOVE confirmation primitive to the Invoking DIMSE Service User.</para>
</listitem>
</orderedlist>
  <para xml:id="para_c4ad8ab5-9752-46ef-a809-90e282910864">The Performing DIMSE Service User may return a C-MOVE response primitive with the status of Failed or Refused before the entire C-MOVE indication (Data Set) has been completely transmitted by the Invoking DIMSE Service User. A C-MOVE response primitive with the status of Success or Warning shall not be returned until the entire C-MOVE indication has been received by the Performing DIMSE Service User.</para>
  <note>
    <orderedlist>
      <listitem>
        <para xml:id="para_7400bff8-d644-4b1e-b584-b675c5dc2300">Notes: Such an occurrence of a "Failed" response is often called an early failed response.</para>
      </listitem>
    </orderedlist>
  </note>
  </section>
</section>
<section label="9.1.5" status="3" xml:id="sect_9.1.5">
    <title>C-ECHO Service</title>
  
  <para xml:id="para_26464b74-8b41-4b06-9b43-c50f949240b6">The C-ECHO service is invoked by a DIMSE Service User to verify end-to-end communications with a peer DIMSE Service User. It is a confirmed service.</para>
  <section label="9.1.5.1" status="4" xml:id="sect_9.1.5.1">
    <title>C-ECHO Parameters</title>
  
    <table frame="box" label="9.1-5" rules="all" xml:id="table_9.1-5">
    <caption>C-ECHO Parameters</caption>
    <thead>
      <tr valign="top">
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_333aaa6e-1a05-40b3-ab49-173b6e4f085f">
            <emphasis role="bold">DIMSE-C Parameter Name</emphasis>
          </para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_2b246651-5bbc-4fb1-aed2-32d50366ccca">
            <emphasis role="bold">Req/Ind</emphasis>
          </para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_77e958a2-9b38-41bb-affe-8ec3e4b5ed3c">
            <emphasis role="bold">Rsp/Conf</emphasis>
          </para>
        </td>
      </tr>
      
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b2e1f8c5-fc5a-4be6-a230-20ece2c495bd">Message ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b045093f-7f36-411c-9ecc-3a57a2f5aeef">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ef8c8179-105e-4bba-9fee-ac50f09149c8">U</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_76d4be3c-46b6-4611-b9b7-6c51793b47d0">Message ID Being Responded To</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_184443d9-9057-4d2b-9359-e84589b3de64">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6c84b85f-c66c-4a0f-a2ad-f3ed26f1fcfb">M</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0afcf2c1-acc2-40eb-b554-3729650d6055">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_93b30ee8-59f8-4658-ba51-3baad2cbc6d8">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_db786ec1-f2a7-493f-b5e9-e41a4bc163b9">U(=)</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5c4d5223-8b04-4d60-8e86-cadb5d515477">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7e50b183-3115-4450-934d-8e3b25dd0da2">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_cc24b7c8-76d1-4d43-af77-36b020444aad">M</para>
      </td>
    </tr>
    </tbody>
  </table>
  <section label="9.1.5.1.1" status="5" xml:id="sect_9.1.5.1.1">
    <title>Message ID</title>
  
  <para xml:id="para_8d21e1ac-c0d1-4213-b594-976e9e04933e">This parameter identifies the operation. It is used to distinguish this operation from other notifications or operations that the DIMSE Service Provider may have in progress. No two identical values for the Message ID (0000,0110) shall be used for outstanding operations or notifications.</para>
  <note>
    <orderedlist numeration="arabic">
      <listitem>
        <para xml:id="para_f88d843a-05db-4c98-9270-943e541d0d3e">Inclusion of this parameter in the confirmation was permitted in previous versions of this Standard but this mode of use is now retired. This parameter may be included in the confirmation but in such a case the Invoking DIMSE Service User should not attach any semantic significance to this parameter.</para>
      </listitem>
      <listitem>
        <para xml:id="para_4b8e14bc-5566-4eea-898a-60d0136b8642">The Message ID (0000,0110) is recommended to be unique within the scope of an Association, to support debug procedures.</para>
      </listitem>
    </orderedlist>
  </note>
  </section>
<section label="9.1.5.1.2" status="5" xml:id="sect_9.1.5.1.2">
    <title>Message ID Being Responded To</title>
  
  <para xml:id="para_3c6c0404-0f4a-4c8b-a0f1-3bbd78a9c7bd">This parameter specifies the Message ID (0000,0110) of the request/indication to which this response/ confirmation applies.</para>
  </section>
<section label="9.1.5.1.3" status="5" xml:id="sect_9.1.5.1.3">
    <title>Affected SOP Class UID</title>
  
  <para xml:id="para_72c89d58-27c5-4d7e-9281-85e107103a4f">For the request/indication, this parameter specifies the SOP Class of the SOP Instance for the verification. It may be included in the response/confirmation. If included in the response/confirmation, this parameter shall be equal to the value in the request/indication.</para>
  </section>
<section label="9.1.5.1.4" status="5" xml:id="sect_9.1.5.1.4">
    <title>Status</title>
  <para xml:id="para_db38ffbd-9fca-41c8-a5d9-35d1aa75f87f">Indicates the status of the response. It may have any of the following values (see also <xref linkend="chapter_C" xrefstyle="template:Annex %n"/>):</para>
  <orderedlist numeration="loweralpha">
<listitem>
    <para xml:id="para_b9bf63c7-79c5-4356-963b-981f8a5eb492">Success (0000H) - This indicates a successful operation.</para>
</listitem>
<listitem>
  <para xml:id="para_79c6de52-7146-4b91-b0de-acbaf8472971">Refused: SOP Class not supported (0122H) - This indicates that a different SOP Class than the Verification SOP Class was specified, which was not supported.</para>
</listitem>
<listitem>
  <para xml:id="para_f40859ce-07a4-439c-b30d-4989baacfebf">Duplicate invocation (0210H) - This indicates that the Message ID (0000,0110) specified is allocated to another notification or operation.</para>
</listitem>
<listitem>
  <para xml:id="para_2da0f57e-bf80-4a35-a1b7-f1d336e0733a">Mistyped argument (0212H) - This indicates that one of the parameters supplied has not been agreed for use on the Association between the DIMSE Service Users.</para>
</listitem>
<listitem>
  <para xml:id="para_8e8de79d-d546-47d8-a989-cdbc8488f374">Unrecognized operation (0211H) - This indicates that a different SOP Class than the Verification SOP Class was specified, which does not recognize a C-ECHO operation.</para>
</listitem>
</orderedlist>
  </section>
</section>
<section label="9.1.5.2" status="4" xml:id="sect_9.1.5.2">
    <title>C-ECHO Service Procedures</title>
  
  <para xml:id="para_7a4a982d-5959-401e-a0e4-798722e41d80">The following C-ECHO procedures apply:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_6b0a6bb6-03a6-40ef-91b7-08258b5a6d3d">The Invoking DIMSE Service User requests verification of communication to the Performing DIMSE Service User by issuing a C-ECHO Request primitive to the DIMSE Service Provider.</para>
</listitem>
<listitem>
<para xml:id="para_fd926eed-b08b-40a1-b046-b70ba84cafdc">The DIMSE Service Provider issues a C-ECHO indication primitive to the Performing DIMSE Service User.</para>
</listitem>
<listitem>
<para xml:id="para_591de41e-19fb-4052-8e39-c9d181a56789">The Performing DIMSE Service User verifies communication by issuing a C-ECHO response primitive to the DIMSE Service Provider.</para>
</listitem>
<listitem>
<para xml:id="para_6213c7a8-04cd-4cfd-b255-f2d82d7756cb">The DIMSE Service Provider issues a C-ECHO confirmation primitive to the Invoking DIMSE Service User, completing the C-ECHO operation.</para>
</listitem>
</orderedlist>
  </section>
</section>
</section>
<section label="9.2" status="2" xml:id="sect_9.2">
    <title>Sequencing</title>
  
  <section label="9.2.1" status="3" xml:id="sect_9.2.1">
    <title>Types of Services</title>
  
  <para xml:id="para_debad837-e739-4305-a0d9-823812557454">All operation and notifications shall be confirmed services.</para>
  </section>
<section label="9.2.2" status="3" xml:id="sect_9.2.2">
    <title>Usage Restrictions</title>
  
  <para xml:id="para_4db7de11-de96-46f8-b390-39a24da94820">These services may only be invoked within the context of an established Association.</para>
  </section>
<section label="9.2.3" status="3" xml:id="sect_9.2.3">
    <title>Disrupted Procedures</title>
  
  <para xml:id="para_9ef4889b-2f49-46de-bd73-8ae806fbd455">These services do not disrupt any other service procedure.</para>
  </section>
<section label="9.2.4" status="3" xml:id="sect_9.2.4">
    <title>Disrupting Procedures</title>
  
  <para xml:id="para_10be78da-cd47-4aec-ae7a-dd5e93289dcd">These services are disrupted by the A-ABORT service procedure.</para>
  </section>
</section>
<section label="9.3" status="2" xml:id="sect_9.3">
    <title>Protocol</title>
  
  <para xml:id="para_4f188dab-e7ed-4092-92f7-59e2b5e7350b">This section specifies the protocol necessary to perform the set of DIMSE-C operations. The Value Representations (VR) specified in the following tables shall be encoded as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>.</para>
  <section label="9.3.1" status="3" xml:id="sect_9.3.1">
    <title>C-STORE Protocol</title>
  
      <para xml:id="para_025dd681-b27e-4d02-84a2-189a02f2838d">The information necessary for the C-STORE Request and C-STORE Indication DIMSE-C primitives are conveyed in the C-STORE-RQ Message. The information necessary for the C-STORE response and confirmation DIMSE-C primitives are conveyed in the C-STORE-RSP Message.</para>
  <section label="9.3.1.1" status="4" xml:id="sect_9.3.1.1">
    <title>C-STORE-RQ</title>
  
  <para xml:id="para_b89c8c7f-62f6-4385-b3b8-034a92557f3c">The C-STORE-RQ Message contains fields as defined in <xref linkend="table_9.3-1" xrefstyle="select: label"/>. Each field shall conform to DICOM encoding and Value Representation as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>. Fields are required as specified in the C-STORE service definition unless otherwise noted in <xref linkend="table_9.3-1" xrefstyle="select: label"/>. Fields not specified in the C-STORE service definition but present in <xref linkend="table_9.3-1" xrefstyle="select: label"/> are required by the DIMSE-C protocol.</para>
    <table frame="box" label="9.3-1" rules="all" xml:id="table_9.3-1">
    <caption>C-STORE-RQ Message Fields</caption>
    <thead>
      <tr valign="top">
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_9af55997-ec9b-4a3c-8d1a-d4df03c34570">
            <emphasis role="bold">Message Field</emphasis>
          </para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_694dddc3-3a56-41d0-b477-e8b170640e00">
            <emphasis role="bold">Tag</emphasis>
          </para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_332dcade-bb2c-4edb-94d6-70b5735b48fa">
            <emphasis role="bold">VR</emphasis>
          </para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_ace6b125-fead-458a-8ffb-7b39e63ca725">
            <emphasis role="bold">VM</emphasis>
          </para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_2049fb72-522f-4a03-bf88-8a3c850ec205">
            <emphasis role="bold">Description of Field</emphasis>
          </para>
        </td>
      </tr>
      
    </thead>
    <tbody>

     <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_474547c4-8b7e-4f6c-8377-11153daeb11f">Command Group Length</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7498ddcb-c9b6-45ce-87e0-f406c66429b4">(0000,0000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_40291b0d-3cd8-495f-b362-333e765d2e2d">UL</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_3fbef2ef-a4bd-418e-814c-03fe06ae07a8">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_cc69f0a2-5178-45bc-b090-55a34815315e">The even number of bytes from the end of the value field to the beginning of the next group.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_56777179-77bb-4437-ace0-558e81034d3f">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_19aebc77-7ce9-4117-9a45-ac29677f76dd">(0000,0002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_47796c07-39b2-42aa-8838-f43228ec0696">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6c9f22c0-a58f-4f8f-8f0f-0203a7d6be98">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_8bfaa5d2-4b5a-4ab4-8b07-be85eabf37d2">SOP Class UID of the SOP Instance to be stored.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6ecb8f43-47a3-431b-8130-acefc703976e">Command Field</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c06d04df-56af-4005-85bf-ed2201e52ac1">(0000,0100)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ab158eea-5f21-4fbf-8d93-657a102f3657">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_dfb4bab1-fdbf-4c32-ba71-8de236e6d175">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a210557c-5723-41de-a35e-51bd84f5ff2b">This field distinguishes the DIMSE-C operation conveyed by this Message. The value of this field shall be set to 0001H for the C-STORE-RQ Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d62f29c9-7827-45a0-9592-65620e3ac480">Message ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_bead5908-a464-4366-966f-2d8c2be836d0">(0000,0110)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_84832b0b-d65d-4fc9-88b1-c9200399ceaa">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e164cb00-6ace-44ba-938e-7daf32b0c5af">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_8ff1d9dd-53d1-4d18-80e8-e6a0d09e1d11">Implementation-specific value. It distinguishes this Message from other Messages.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_cc554d1b-55de-47ad-ba6b-ba21318a2ec8">Priority</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_3e84e7f7-14a4-47ec-96ab-e95500d704fb">(0000,0700)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_aa4ccf75-9f70-46bb-a47f-f8970bf76552">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e4ec6dec-e027-485d-8eda-fa1a9df05f7b">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a5916ddc-fe26-4514-84a2-1277b19463b2">The priority shall be set to one of the following values:</para>
        <para xml:id="para_419a9d87-ffd4-4123-9f8a-a033ac2369bb">LOW = 0002H</para>
        <para xml:id="para_09588b44-3ceb-45b1-b623-e28c39a84654">MEDIUM = 0000H</para>
        <para xml:id="para_9e7227da-34bf-4bd8-a14c-5cb86b922ea4">HIGH = 0001H</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3c9972f2-d03c-44e7-b280-6a2d0e2a3576">Command Data Set Type</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8c34cf48-216f-4863-a3aa-a0cbadfaa3f1">(0000,0800)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c9e3f007-d436-4691-adc4-575f8fcfd7aa">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_79e0ab2a-0c9c-4b3d-add8-5addb5b97e0a">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_34c3fc4d-f1a9-4f72-a088-c0a1005fb20a">This field indicates that a Data Set is present in the Message. It shall be set to any value other than 0101H (Null).</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b061bb73-8899-4cec-a465-f7bb278966e8">Affected SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7d9bf85d-a11b-4e37-8f01-ccae0a57e4ce">(0000,1000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8da881f8-8b1c-48f5-8b80-b8ff0fd7d431">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4982d71d-2609-409e-9876-4b276e9273e5">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5d24c202-48e6-4eb8-8225-382780a1014a">Contains the UID of the SOP Instance to be stored.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3354375e-30e8-4f05-b9bb-26e592231163">Move Originator Application Entity Title</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_495f8c2b-6b1f-4af8-85e1-110643b6c564">(0000,1030)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9c40dacd-09a2-493f-b8da-d41e5ac3c2b2">AE</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_db2c0bbf-90a7-433a-8f5e-b9edabe214fb">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_91fad5dd-93f1-42c5-8cae-4363fe4c684f">Contains the DICOM AE Title of the DICOM AE that invoked the C-MOVE operation from which this C-STORE sub-operation is being performed.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0d1266d5-7dde-4702-8ceb-51c236faecf7">Move Originator Message ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_42509ad3-8b0d-4b9e-9bf7-ced00b9174ae">(0000,1031)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ffaee058-d655-4311-a6a8-430573a8262d">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e749f635-7e6d-425d-93e0-cc31b0a61c84">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1be1e178-6be5-4492-ba00-33d98b61b1d7">Contains the Message ID (0000,0110) of the C-MOVE-RQ Message from which this C-STORE sub-operations is being performed.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3bbb7491-12df-4450-946f-7e7265770720">Data Set</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_85720fca-52df-4fe8-9b11-99cdefaff3f8">(no tag)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e4e0377a-fa88-4b4d-9111-f91df4ce80e0">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c3117455-8782-40d5-b8d6-74d3f3277c28">-</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0459d4d9-ecb0-4206-af50-00366008408e">Application-specific Data Set.</para>
      </td>
    </tr>
    </tbody>
  </table>
  <note>
    <para xml:id="para_48252b33-fe7f-4748-a31b-9a35279c1f9f">The contents of Composite Information Object Definitions, encoded as a series of Data Elements, are defined in <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/> and <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>
</para>
  </note>
  </section>
<section label="9.3.1.2" status="4" xml:id="sect_9.3.1.2">
    <title>C-STORE-RSP</title>
  
  <para xml:id="para_aa062dad-2151-4b2a-b099-feabc0898c11">The C-STORE-RSP Message contains fields as defined in <xref linkend="table_9.3-2" xrefstyle="select: label"/> and in <xref linkend="chapter_C" xrefstyle="template:Annex %n"/>. Each field shall conform to DICOM encoding and Value Representation as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/> of the DICOM Standard. Fields are required as specified in the C-STORE service definition unless otherwise noted in <xref linkend="table_9.3-2" xrefstyle="select: label"/>. Fields not specified in the C-STORE service definition but present in <xref linkend="table_9.3-2" xrefstyle="select: label"/> are required by the DIMSE-C protocol.</para>
    <table frame="box" label="9.3-2" rules="all" xml:id="table_9.3-2">
    <caption>C-STORE-RSP Message Fields</caption>
    <thead>
      <tr valign="top">
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_a812e995-3970-41d5-92d5-3146f07221ba">
            <emphasis role="bold">Message Field</emphasis>
          </para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_fac27d24-dcb8-4b5b-af19-0b2cc9a7e494">
            <emphasis role="bold">Tag</emphasis>
          </para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_77d79c3e-1703-44fc-b741-18209892b2f4">
            <emphasis role="bold">VR</emphasis>
          </para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_517921b4-cb3a-492f-8331-c8bcca1e510e">
            <emphasis role="bold">VM</emphasis>
          </para>
        </td>
        <td align="center" colspan="1" rowspan="1">
          <para xml:id="para_29a787ac-f57f-4b8d-8f2d-efe50521948e">
            <emphasis role="bold">Description of Field</emphasis>
          </para>
        </td>
      </tr>
      
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_848ee563-763c-4ca2-a2e0-92a1636323d9">Command Group Length</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4ee4e6c6-19b7-4a36-a42f-2b063adcf4e0">(0000,0000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9a4702d4-77a1-4e74-8c16-e11d15d41514">UL</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_bcc72911-dd51-47fe-9760-f1a237f84992">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0b1b83df-1d69-40e9-a390-e1cb37f56973">The even number of bytes from the end of the value field to the beginning of the next group.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_26622104-41b2-4897-b039-38d6b352d803">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0a921457-90a8-4a00-a60b-748b2e1018fe">(0000,0002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_eca00dc6-91bf-4ceb-8f94-0555fec1fa4f">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_627f368d-a240-490f-8f4a-5fee24dc1c3e">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_59086497-8c51-4cb9-8fe8-695d9ddf8748">Contains the SOP Class of the SOP Instance stored.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_90c716cf-fc69-49bd-9583-3dedad33644b">Command Field</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0d8d0b8e-e088-412c-9dc9-45bf8285f2cc">(0000,0100)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8b99b350-49ff-4206-bc52-496c844913bd">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f3451de3-e4ee-46b5-ae99-7b63b76377aa">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e8a26897-448d-45a6-a0b3-0724524e2717">This field distinguishes the DIMSE-C operation conveyed by this Message. The value of this field shall be set to 8001H for the C-STORE-RSP Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b041bdf6-a944-4306-b7ce-c4371a944599">Message ID Being Responded To</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_33255427-97cc-4ce8-b822-18fb1ea042c0">(0000,0120)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_438dfede-c01a-4305-af3c-a12c3da4689a">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_073ade58-2f89-498e-a6e0-3529e1a95cec">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6683ac19-db14-4be4-af87-1e0abdc7f4e7">Shall be set to the value of the Message ID (0000,0110) field used in associated C-STORE-RQ Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e46267e6-85c4-456b-aa19-fee12aaac8c1">Command Data Set Type</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1b92b471-f5ea-4694-b832-eed9d2456cb9">(0000,0800)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2d937dd0-60ff-4e50-ae9e-3cd20c547bf9">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9c731929-dafa-49fd-832a-391a4e22489e">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_70f405e0-79e7-4bf0-a7dd-8217ad57660b">This field indicates that no Data Set is present in the Message and shall be set to a value of 0101H (Null).</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_158166c0-9f1b-4c36-aa3e-4ea8cc7bae90">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6bed570d-a1ed-4ce8-bdb3-8e01627de759">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_154a3a6c-a109-47a0-acb2-14c878e539ff">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e942fec7-0988-4fb1-a97c-79aef1c96abf">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_96dbc267-8ffb-4fa7-94d4-bc09e3bae5e8">The value of this field depends upon the status type. <xref linkend="chapter_C" xrefstyle="template:Annex %n"/> defines the encoding of the status types defined in the service definition.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_baebcad3-6a9b-488f-8661-a95a2c5ef094">Affected SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_888375f1-e0ed-437e-a24a-10396bd96aa7">(0000,1000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e5712029-afee-4817-8c66-e85161c6c2be">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8d1b5236-a0d8-497f-80f5-102b4deb05bb">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_ef9e99ec-384c-46e1-a2bd-be4e80ad237f">Contains the UID of the SOP Instance stored.</para>
      </td>
    </tr>
    </tbody>
  </table>
  </section>
<section label="9.3.1.3" status="4" xml:id="sect_9.3.1.3">
    <title>C-STORE Protocol Procedures</title>
  
  <para xml:id="para_010ed68b-9d07-48cf-bb58-62729bf12b7a">The C-STORE procedures are initiated by the Invoking DIMSE Service User issuing a C-STORE Request primitive. On receipt of the C-STORE Request primitive the DIMSE-C protocol machine shall:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_bd0f09b5-16e6-4e30-be1d-f9156a641143">construct a Message conveying the C-STORE-RQ</para>
</listitem>
  <listitem>
<para xml:id="para_7de75aff-6b1c-4caa-97bc-c266744d7fda">send the Message using the P-DATA request service (see 8.1)</para>
</listitem>
</itemizedlist>
  <para xml:id="para_5a55ffa7-1c4a-47ee-98dc-6535e89a90f0">On receipt of a Message conveying a C-STORE-RQ the DIMSE-C protocol machine shall issue a C-STORE indication primitive to the Performing DIMSE Service User.</para>
  <para xml:id="para_24a8f232-832d-4bd3-89e6-a43fb0dab093">On receipt of the C-STORE response primitive, issued by the Performing DIMSE Service User, the DIMSE-C protocol machine shall:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_a9ee6be6-b7d5-4753-b925-480d94e498f4">construct a Message conveying the C-STORE-RSP</para>
</listitem>
  <listitem>
<para xml:id="para_d5cc6ef3-1fdf-495b-b04b-8fcb40b1a5cd">send the Message using the P-DATA request service (see 8.1)</para>
</listitem>
</itemizedlist>
  <para xml:id="para_e5d0172f-2deb-409f-9f95-6ae8ac48c972">On receipt of a Message conveying a C-STORE-RSP the DIMSE-C protocol machine shall issue a C-STORE confirmation primitive to the Invoking DIMSE Service User, thus completing the C-STORE procedure.</para>
  <para xml:id="para_89be2cc1-b8ed-4e2d-aca8-20d51a33501b">The Performing DIMSE Service User may return a C-STORE-RSP with the status of Failed or Refused before the complete C-STORE-RQ request Message has been completely transmitted by the Invoking DIMSE Service User (this is called an early failed response). Upon receipt of this Failed or Refused C-STORE-RSP the Invoking DIMSE Service User may terminate the Message before it is completely sent (i.e., set the Last Fragment bit to 1 in a Data PDV for this Message, see <xref linkend="chapter_F" xrefstyle="template:Annex %n"/>). Following this, it may invoke another operation or notification. It is a protocol violation for an Invoking DIMSE Service User to set the Last Fragment bit to 1 before a C-STORE-RQ Message has been completely transmitted if it has not received a Failed or Refused C-STORE-RSP to that request.</para>
  <note>
    <para xml:id="para_73e8ad18-0961-45b7-af6a-f6cb7a8ac332">When an Association is operating in asynchronous mode, it is possible for an Invoking DIMSE Service User to transmit several Messages before a response. Therefore, while sending a Message it may receive a response to a previously transmitted Message. In this case this response is not an early failed response because the related Message has already been sent.</para>
  </note>
  </section>
</section>
<section label="9.3.2" status="3" xml:id="sect_9.3.2">
    <title>C-FIND Protocol</title>
  
    <para xml:id="para_054c72ac-f638-415c-beeb-e18f7267937c">The information necessary for the C-FIND Request and C-FIND Indication DIMSE-C primitives are conveyed in the C-FIND-RQ Message. The information necessary for the C-FIND response and confirmation DIMSE-C primitives are conveyed in the C-FIND-RSP Message. The information necessary for the C-FIND Cancel Request and C-FIND Cancel Indication primitives are conveyed in the C-CANCEL-FIND-RQ Message.</para>
  <section label="9.3.2.1" status="4" xml:id="sect_9.3.2.1">
    <title>C-FIND-RQ</title>
  
  <para xml:id="para_e7a0e761-981f-495d-9ec7-d2998faa6688">The C-FIND-RQ Message contains fields as defined in <xref linkend="table_9.3-3" xrefstyle="select: label"/>. Each field shall conform to DICOM encoding and Value Representation as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>. Fields are required as specified in the C-FIND service definition unless otherwise noted in <xref linkend="table_9.3-3" xrefstyle="select: label"/>. Fields not specified in the C-FIND service definition but present in <xref linkend="table_9.3-3" xrefstyle="select: label"/> are required by the DIMSE-C protocol.</para>
    <table frame="box" label="9.3-3" rules="all" xml:id="table_9.3-3">
    <caption>C-FIND-RQ Message Fields</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_3f128c92-4ab0-45c9-aeea-225fc8fb1397">
          <emphasis role="bold">Message Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_04cb37df-2b76-49f5-ac76-608787923ceb">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_b0115c0a-1844-42c5-8fab-e7f1d4d8fdee">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_422b439a-186b-4da2-af0d-9089c7828318">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_a0237e6d-b8b4-4c97-883a-8076a51a6234">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_be1ba7e0-a3a1-4794-b025-596af9b1bb94">Command Group Length</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9cd943c2-eb99-4139-a605-14e5fabbff94">(0000,0000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e2968cc6-15be-4c7c-9c34-1a0934915db4">UL</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0de6d63b-4b83-4517-8b44-be23fd259de7">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_2ca44725-3fe8-4964-95b2-c371c5a4bb45">The even number of bytes from the end of the value field to the beginning of the next group.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b101bd50-9cff-4f5b-96c3-8b5b63621440">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c8be038f-5149-412c-ba61-7e6ee0ab4526">(0000,0002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1a1c88e8-13e1-4d46-a1fc-221747be507b">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d2f656be-eb7a-4e27-8946-895a3138512f">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_2298c8a4-8748-48b7-be60-a7371375a68d">SOP Class UID associated with this operation.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b3e683ee-9f59-41a1-bf53-bd30a570454f">Command Field</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_93aea051-9a7a-4773-bcb6-81b4e8eb091e">(0000,0100)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_492179e7-e7dd-4cd5-8141-d498c5e16bbf">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f089f1a7-2049-43b6-8364-697bfa75afaa">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_4237e878-88d9-4174-bce0-500e1c9ed7ae">This field distinguishes the DIMSE-C operation conveyed by this Message. The value of this field shall be set to 0020H for the C-FIND-RQ Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9750fead-ccb1-4b64-89b6-b08d93ac1d98">Message ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ae431488-266b-4d5a-a3fa-b7d9c1728dc1">(0000,0110)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_441a1f7b-882c-42d0-a12c-0b94c9238301">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_677a6b3f-4049-4077-8627-3aaad50322a2">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_909d692d-6e2b-44b2-92e8-5395011ebd0f">Implementation-specific value that distinguishes this Message from other Messages.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_509a3f2a-001a-4d17-9f2c-ad2588b1da86">Priority</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_70694367-10e5-474e-bbfe-575b62c1cc0b">(0000,0700)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_50eabbe1-2291-4d1e-8b91-08c81a4e0ae0">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2e6ef3c9-22cf-47de-ba67-52f4ac54732a">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_10d9547a-277f-41da-9b65-448002605369">The priority shall be set to one of the following values:</para>
        <para xml:id="para_64cbea2d-e2eb-476a-b41f-dbdb44823152">LOW = 0002H</para>
        <para xml:id="para_d3c9aaa5-94d1-47ca-8851-96c16ebc8191">MEDIUM = 0000H</para>
        <para xml:id="para_857635bf-05d0-4562-a9b1-cca15347d7de">HIGH = 0001H</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_7cab38b7-9657-4100-9a66-e39a9ddb9b14">Command Data Set Type</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c5bbe940-2514-4154-a166-5067c1815962">(0000,0800)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ac3ee802-9035-4e14-954b-3f435ceabe3f">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ad71c19a-21cd-4316-a1ea-cc8d6dc551a6">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a3008823-b807-400b-89a0-08991cd872ff">This field indicates that a Data Set is present in the Message. It shall be set to any value other than 0101H (Null).</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c37f6f91-d2de-48f1-a52b-a3f4c6275a33">Identifier</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_55c2a7d3-52ab-49ac-b0d9-d4e90e15d816">(no tag)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f27426d9-9663-4110-86e4-31db2a83d578">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2c13a3dc-a573-48ad-a126-914f19c07d6c">-</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a237c53a-740e-4cd8-b815-4d7b6aec8616">A Data Set that encodes the Identifier to be matched. See <xref linkend="sect_9.1.2.1.5" xrefstyle="select: label"/>.</para>
      </td>
    </tr>
    </tbody>
  </table>
  <note>
    <para xml:id="para_29923076-96d0-42d7-b0b4-aaadbedf2c30">Implementations that require compatibility to previous versions of this Standard must set the Command Data Set Type (0000,0800) Field to 0102H (Identifier).</para>
  </note>
  </section>
<section label="9.3.2.2" status="4" xml:id="sect_9.3.2.2">
    <title>C-FIND-RSP</title>
  
  <para xml:id="para_6592f37e-0a90-4581-8eab-27f808a51c4b">The C-FIND-RSP Message contains fields as defined in <xref linkend="table_9.3-4" xrefstyle="select: label"/> and in <xref linkend="chapter_C" xrefstyle="template:Annex %n"/>. Each field shall conform to DICOM encoding and Value Representation as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>. Fields are required as specified in the C-FIND service definition unless otherwise noted in <xref linkend="table_9.3-4" xrefstyle="select: label"/>. Fields not specified in the C-FIND service definition but present in <xref linkend="table_9.3-4" xrefstyle="select: label"/> are required by the DIMSE-C protocol.</para>
    <table frame="box" label="9.3-4" rules="all" xml:id="table_9.3-4">
    <caption>C-FIND-RSP Message Fields</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_1e098ebe-8895-420a-993e-af94a517ea9a">
          <emphasis role="bold">Message Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_8b6ba828-40dd-430d-bdc8-f1d1348b1af6">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_182a558c-8090-4928-91ce-b4f34dfb40f7">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_31ef5eb3-6cc9-43d9-94bc-07806a82a4aa">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_e30b9f35-0dfe-46f8-b8e5-5eb870523aa6">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_336f5636-d668-40e0-9829-5a873f9d1e3a">Command Group Length</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_247d0623-1404-4f95-a123-53e211fc0e9b">(0000,0000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_546b7756-bc0b-474c-8f0a-52b8fd7228d4">UL</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0fee9355-da0c-409d-bec2-4ce89ad4bb55">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_8ef5fd11-05f1-40e4-9e0c-5e6d7243e1bd">The even number of bytes from the end of the value field to the beginning of the next group.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_794d5eca-1d35-4118-b556-de45ac3a8304">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_86743425-7535-415d-9ce2-076ecd44832a">(0000,0002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c5f6ac48-2d9e-42bd-8420-1b5b90275647">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_941e3877-8a15-428e-a4e1-25347bd65c1d">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_49de2d19-b121-40a1-919a-878c6cac82e9">SOP Class UID associated with the operation.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d89424e9-c048-406d-9e83-f24f55706594">Command Field</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f30e307c-e2bb-4e17-a7ea-8d570918339e">(0000,0100)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_343dd205-63a1-487e-851d-34463ddbce78">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8a1bd143-7b76-4e96-b475-a515f27ffc5b">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_870b94f4-74bb-4430-aacb-c547fa08bc09">This field distinguishes the DIMSE-C operation conveyed by this Message. The value of this field shall be set to 8020H for the C-FIND-RSP Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_bb6085a9-e356-4276-8fd9-21c80ec87f4e">Message ID Being Responded To</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9340da8c-f7a0-4e57-89dc-a153c4b00da0">(0000,0120)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_441e04e5-0984-4c8d-9290-f5275ce84090">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b4b9da95-06fb-4cc4-8ebe-41ba2980892d">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6a784bab-4615-4278-80e5-763fb3d2e5fd">Shall be set to the value of the Message ID (0000,0110) field used in associated C-FIND-RQ Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_24bf21b1-f53d-4302-a7b9-c09ad0a59780">Command Data Set Type</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_59fb3bcf-4e02-499c-93f7-e4ae709c1d17">(0000,0800)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2eac08ed-e51d-4229-b61d-a15ce10e4c64">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d4b846f4-6e79-49c9-8975-840715c5a43f">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_216cc39f-6fde-40a4-9687-e334181169e4">This field indicates if a Data Set is present in the Message. This field shall be set to the value of 0101H (Null) if no Data Set is present; any other value indicates a Data Set is included in the Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_7d6d2018-c005-4360-ac35-083890a37964">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c8657ecd-65dd-46ec-925c-3d09e52b7bfe">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2c80805a-a549-4cad-a38a-466da4d04031">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c97f4efd-1405-4eb4-98fe-7c003f6fac2e">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_627c3cad-38a5-460d-90de-7d37e3d0d84b">The value of this field depends upon the status type. <xref linkend="chapter_C" xrefstyle="template:Annex %n"/> defines the encoding of the status types defined in the service definition.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0985859e-0cef-46a6-8c41-99ed04fd7ff1">Identifier</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e2dbd7cc-b214-4e34-9815-87f1bff2307b">(no tag)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_68fba8f4-4b2b-4009-be58-3c29c49be1b1">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_71d1b5d6-eb10-475e-b7ab-929c2e5fe696">-</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_bac00488-33b3-47f7-bf7c-0c5495772172">A Data Set that encodes the Identifier that was matched. See <xref linkend="sect_9.1.2.1.5" xrefstyle="select: label"/>.</para>
      </td>
    </tr>
    </tbody>
  </table>
  </section>
<section label="9.3.2.3" status="4" xml:id="sect_9.3.2.3">
    <title>C-CANCEL-FIND-RQ</title>
  
  <para xml:id="para_d5bd2253-55bd-4623-a4ea-3b8ad54ec25b">The C-CANCEL-FIND-RQ Message contains fields as defined in <xref linkend="table_9.3-5" xrefstyle="select: label"/>. Each field shall conform to DICOM encoding and Value Representation as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>. Fields are required as specified in the C-FIND service definition unless otherwise noted in <xref linkend="table_9.3-5" xrefstyle="select: label"/>. Fields not specified in the C-FIND service definition but present in <xref linkend="table_9.3-5" xrefstyle="select: label"/> are required by the DIMSE-C protocol.</para>
    <table frame="box" label="9.3-5" rules="all" xml:id="table_9.3-5">
    <caption>C-CANCEL-FIND-RQ Message Fields</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_2e5bfdf8-c9b4-4d33-a497-d6a28505e12f">
          <emphasis role="bold">Message Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_ba151265-0048-4f37-8311-7b2fed5ca700">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_b7e84181-0632-4ae9-b1b2-300ded325288">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_071ec967-ea09-4c05-8705-433871cd983c">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_082dac08-e877-43e1-9ef1-bd02e3bfd24e">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_84b2c998-ca2e-4def-99d1-f59312fb61e0">Command Group Length</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0e0572cc-c331-4935-ada1-68f24cd1fcb0">(0000,0000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7d9bc730-62e9-4373-abad-93590d317666">UL</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_07df37c5-6eeb-48c2-8016-df6405f4bfaa">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9661bcf0-fe85-4d4a-a459-a2a003ee3c66">The even number of bytes from the end of the value field to the beginning of the next group.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_4650be78-66f5-42b2-ac86-2bbd3ee345f4">Command Field</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8ccf10af-18a2-44d1-95bf-232f22699092">(0000,0100)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f68d6166-94bd-4908-8abc-44ae996b11ef">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b7f978d5-386a-41f2-8ec9-48f5f8fc8b37">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_7e3a2be2-6a3c-4b10-b8a7-3e7a054c6ddd">This field distinguishes the DIMSE-C operation conveyed by this Message. The value of this field shall be set to 0FFFH for the C-CANCEL-FIND-RQ Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_91e24017-b11d-4ba4-aaef-452521c922ca">Message ID Being Responded To</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ce10819e-ef8c-4447-a39b-d28b9c8d4f6a">(0000,0120)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b175fdb4-ffcc-41bb-ae36-35dc93bddbc2">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_bfee3c2e-40b7-4721-b2d1-85cb303661a7">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_fa23b509-cf79-476f-a77e-1bed71fe9c90">Shall be set to the value of the Message ID (0000,0110) field used in associated C-FIND-RQ Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1b71a89b-f9e5-4f8e-bd92-0ac5b28dadd6">Command Data Set Type</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_46040c9a-1c34-492e-9cf5-93db1bba0eb6">(0000,0800)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0f9f29d2-7c49-4626-8b9d-9b07c3eb4d62">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ecb9d2fd-1ebd-4281-860b-4151bf55b7c5">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_cdeedb03-e6eb-4452-ab5e-809c96ae88f1">This field indicates that no Data Set is present in the Message and shall be set to a value of 0101H.</para>
      </td>
    </tr>
    </tbody>
  </table>
  </section>
<section label="9.3.2.4" status="4" xml:id="sect_9.3.2.4">
    <title>C-FIND Protocol Procedures</title>
  
  <para xml:id="para_cb66fa43-9c92-4160-bd03-1b2bdcf240c3">The C-FIND procedures are initiated by the Invoking DIMSE Service User issuing a C-FIND Request primitive. On receipt of the C-FIND Request primitive the DIMSE-C protocol machine shall:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_eb0d75db-c08f-48e4-8664-dbb1cc327d60">construct a Message conveying the C-FIND-RQ</para>
</listitem>
  <listitem>
<para xml:id="para_cc425e9d-951b-42a7-b140-5745222b0713">send the Message using the P-DATA request service (see 8.1)</para>
</listitem>
</itemizedlist>
  <para xml:id="para_de391f4c-8419-4325-bcac-2010d4c75c80">On receipt of a Message conveying a C-FIND-RQ the DIMSE-C protocol machine shall issue a C-FIND indication primitive to the Performing DIMSE Service User.</para>
  <para xml:id="para_39cffcbb-8e0f-4a72-a264-800bd2481746">The DIMSE-C protocol machine shall:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_95b7915c-bdb3-4220-9bbf-ceb78508e12b">accept zero or more C-FIND response primitives containing the status of Pending, issued by the Performing DIMSE Service User, followed by a single C-FIND response primitive containing the final status</para>
</listitem>
  <listitem>
    <para xml:id="para_0e6faeb7-4b82-41a7-8d57-843129261530">for each C-FIND response primitive containing the Pending status the DIMSE-C protocol machine shall:</para>
    <orderedlist numeration="loweralpha">
      <listitem>
<para xml:id="para_1a7f75f4-3bac-4929-8270-c9f7e74f1726">construct a Message conveying the (Pending) C-FIND-RSP</para>
</listitem>
      <listitem>
<para xml:id="para_a3b934ba-3007-4f46-9a6e-68a9ab638424">send the Message using the P-DATA request service (see 8.1)</para>
</listitem>
    </orderedlist>
  </listitem>
  <listitem>
    <para xml:id="para_fa83f571-8f82-49c2-92f4-a3a70cb88702">for the C-FIND response primitive containing the final status the DIMSE-C protocol machine shall:</para>
    <orderedlist numeration="loweralpha">
      <listitem>
<para xml:id="para_40781e42-2299-4921-9a3f-8efa9d4e664f">construct a Message conveying the (final) C-FIND-RSP</para>
</listitem>
      <listitem>
<para xml:id="para_a0274280-4b99-4714-b056-b02e011c8c59">send the Message using the P-DATA request service (see 8.1)</para>
</listitem>
    </orderedlist>
  </listitem>
</itemizedlist>
  <para xml:id="para_9a28b5ba-e18e-4f23-8209-92789780a1f9">On receipt of a Message conveying a C-FIND-RSP the DIMSE-C protocol machine shall:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_7e8a60d9-8c64-4fb5-b6fa-bd01b276cf3e">if the Message indicates the status of Pending, issue a C-FIND confirmation primitive to the Invoking DIMSE Service User with a Pending status</para>
</listitem>
  <listitem>
<para xml:id="para_b7a32a67-5f7f-4885-9377-64e6069f74c4">if the Message indicates a final status, issue a C-FIND confirmation primitive to the Invoking DIMSE Service User with a final status, thus completing the C-FIND procedure</para>
</listitem>
</itemizedlist>
  <note>
    <para xml:id="para_d4c81286-e14a-4d9d-857c-93d9b14ae8e2">The C-FIND procedures can be canceled at any time by the Invoking DIMSE Service User. This is accomplished by the Invoking DIMSE Service User issuing a C-CANCEL Request primitive.</para>
  </note>
  <para xml:id="para_64604cf2-ce70-49cf-81ca-5962700478c1">The Performing DIMSE Service User may return a C-FIND-RSP with the status of Failed or Refused before the complete C-FIND-RQ request Message has been completely transmitted by the Invoking DIMSE Service User (this is called an early failed response). Upon receipt of this Failed or Refused C-FIND-RSP the Invoking DIMSE Service User may terminate the Message before it is completely sent (i.e., set the Last Fragment bit to 1 in a Data PDV for this Message, see <xref linkend="chapter_F" xrefstyle="template:Annex %n"/>). Following this, it may invoke another operation or notification. It is a protocol violation for an Invoking DIMSE Service User to set the Last Fragment bit to 1 before a C-FIND-RQ Message has been completely transmitted if it has not received a Failed or Refused C-FIND-RSP to that request.</para>
  <note>
    <para xml:id="para_f6d73c39-be86-41da-93ce-e681f269b14a">When an Association is operating in asynchronous mode, it is possible for an Invoking DIMSE Service User to transmit several Messages before a response. Therefore, while sending a Message it may receive a response to a previously transmitted Message. In this case this response is not an early failed response because the related Message has already been sent.</para>
  </note>
  </section>
</section>
<section label="9.3.3" status="3" xml:id="sect_9.3.3">
    <title>C-GET Protocol</title>
  
    <para xml:id="para_4e00e03e-f55e-41ec-aa61-49c10960e37b">The information necessary for the C-GET Request and C-GET Indication DIMSE-C primitives are conveyed in the C-GET-RQ Message. The information necessary for the C-GET response and confirmation DIMSE-C primitives are conveyed in the C-GET-RSP Message. The information necessary for the C-GET Cancel Request and Cancel Indication primitives are conveyed in the C-CANCEL-GET-RQ Message.</para>
  <section label="9.3.3.1" status="4" xml:id="sect_9.3.3.1">
    <title>C-GET-RQ</title>
  
  <para xml:id="para_d8a0657d-9782-41cf-86c7-d5799a1be0d9">The C-GET-RQ Message contains fields as defined in <xref linkend="table_9.3-6" xrefstyle="select: label"/>. Each field shall conform to DICOM encoding and Value Representation as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>. Fields are required as specified in the C-GET service definition unless otherwise noted in <xref linkend="table_9.3-6" xrefstyle="select: label"/>. Fields not specified in the C-GET service definition but present in <xref linkend="table_9.3-6" xrefstyle="select: label"/> are required by the DIMSE-C protocol.</para>
    <table frame="box" label="9.3-6" rules="all" xml:id="table_9.3-6">
    <caption>C-GET-RQ Message Fields</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_990d8ddf-c85e-42a2-a3fc-7f09d4caf17d">
          <emphasis role="bold">Message Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_fded08f0-9b16-45ff-a8f3-5eba13d65c61">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_f6ecae12-c00d-4bde-84b6-057ebceb2b1b">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_fe0694ad-b318-4c82-afd1-f43cdeebae91">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_37039ef4-f5b4-448b-ba27-2c70ac433ad6">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_bc40ef42-da9a-4e22-a17e-298ecf598970">Command Group Length</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_457c0565-ab3e-4a6c-aeac-8e24f065c1d5">(0000,0000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6108eb98-294a-4b33-8192-429a94090282">UL</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7bec5b88-c6f8-4bcb-a5e7-7324a90f7ccc">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_ac4cd192-de62-4d6a-a3bc-3f5dcbd59801">The even number of bytes from the end of the value field to the beginning of the next group.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_73457fb3-29dd-422c-89d4-ffd6e9f737a4">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_cee76ca8-0491-4751-8ec7-82f6caed2c09">(0000,0002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8fb892f5-bb37-49f8-ac39-4a005f131095">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_eb9a928f-850e-4839-bf26-1cf5c67d5e8d">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_640e60e0-4467-479b-ad43-0fd4d4b54731">SOP Class UID associated with this operation.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3fa2dfca-e844-4dfa-838a-b7673f646226">Command Field</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c8f09f1c-90c7-4305-a281-60f662fc985f">(0000,0100)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8506ca4b-0af0-458c-b703-33e934c5726a">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2eefecb7-6856-464d-aff1-6942b4964c1c">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a6a49397-f7b4-4842-b513-d7cde3b72ed0">This field distinguishes the DIMSE-C operation conveyed by this Message. The value of this field shall be set to 0010H for the C-GET-RQ Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_ba3eab70-23fa-4637-896a-ec0dd0e42c97">Message ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_20910633-08b8-48a1-b9d7-9f281f9ddb80">(0000,0110)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_80287b6f-5346-4564-a42c-4f2cb4a9ee69">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b7912a1f-8611-4476-ae81-722884cf6ed2">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b52b92f5-f9f9-4c14-ae81-58ce59e668b6">Implementation-specific value that distinguishes this Message from other Messages.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_090f7dc1-3fea-46f5-8699-667b1be93a92">Priority</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_81449eb1-352b-458e-ae18-a8423f22b565">(0000,0700)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e8ca5f3a-5b92-49c3-a72b-43f182543522">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_16541dd2-e980-4e17-9869-4947f16c6129">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f2ebdda1-0838-48f1-b725-763d6ec961be">The priority shall be set to one of the following values:</para>
        <para xml:id="para_2a0bc194-5c69-4af9-b191-2f1637fbfe08">LOW = 0002H</para>
        <para xml:id="para_ddf16570-3177-401a-a552-33499e517671">MEDIUM = 0000H</para>
        <para xml:id="para_b2b771eb-c5f5-4a5c-99a7-722d568f59b3">HIGH = 0001H</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f715a096-7143-41e0-8d84-b4dfdd61ced0">Command Data Set Type</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_632c7983-bd57-44ac-bdd7-80bacf523114">(0000,0800)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2af920bb-12f4-422a-8a20-4951105aa00b">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d4fe24ba-9650-468d-a415-25254e32016e">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d7d88c7c-de61-4f82-9012-dd8e60722769">This field indicates that a Data Set is present in the Message. It shall be set to any value other than 0101H (Null).</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0f88f865-107f-4cb0-b685-5bf66d3d2557">Identifier</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7c5078c1-bcd2-4675-8a40-9928c72e9a7d">(no tag)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0def4a58-47a5-4790-9df5-48e092c4619a">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9c65aec0-5500-4b68-8a8a-1c0ecb9c1115">-</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f6160e4a-9a57-4ee6-b046-58d690eb7bd0">A Data Set that encodes attributes providing status information about the C-GET operation. See <xref linkend="sect_9.1.3.1.5" xrefstyle="select: label"/>.</para>
      </td>
    </tr>
    </tbody>
  </table>
  <note>
    <para xml:id="para_967dde88-d344-49e6-8bd3-9e7d85126835">Implementations that require compatibility to previous versions of this Standard must set the Command Data Set Type (0000,0800) Field to 0102H (Identifier).</para>
  </note>
  </section>
<section label="9.3.3.2" status="4" xml:id="sect_9.3.3.2">
    <title>C-GET-RSP</title>
  
  <para xml:id="para_ab889526-6fe2-43ad-b782-125a17ab5b1e">The C-GET-RSP Message contains fields as defined in <xref linkend="table_9.3-7" xrefstyle="select: label"/> and in <xref linkend="chapter_C" xrefstyle="template:Annex %n"/>. Each field shall conform to DICOM encoding and Value Representation as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>. Fields are required as specified in the C-GET service definition unless otherwise noted in <xref linkend="table_9.3-7" xrefstyle="select: label"/>. Fields not specified in the C-GET service definition but present in <xref linkend="table_9.3-7" xrefstyle="select: label"/> are required by the DIMSE-C protocol.</para>
    <table frame="box" label="9.3-7" rules="all" xml:id="table_9.3-7">
    <caption>C-GET-RSP Message Fields</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_27eeecd4-76d2-4b44-8cb3-ca2b3e0862ac">
          <emphasis role="bold">Message Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_7b7e1845-a66a-4163-b24e-d357985d721d">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_20e29c41-bd8e-4ed8-ae88-9031fcc8851c">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_9455b731-972e-4ced-9eb0-cadf89984606">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_b07b1a0d-c245-4536-9761-7118af3b73bf">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6fc9da19-fe2f-4f67-bb90-2792d4a6792b">Command Group Length</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9d288879-b032-41c2-aefd-88f330e695a1">(0000,0000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_52cf60e4-de4f-4a09-867f-c76b12507c4e">UL</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b8e317ce-1f09-4f72-8634-2bd76c941121">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_37ac35cd-e062-46e9-886e-3880d9bd8da8">The even number of bytes from the end of the value field to the beginning of the next group.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_423aa836-37b9-4611-a492-1baf99da60e7">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_bc71fd41-69a1-4cdd-8cff-062a81d4df0c">(0000,0002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f7da6c42-73f5-4cfd-a569-cb988e9c2462">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_74fe733f-f0af-4ae4-aa9a-ca2ec0b97eb8">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_34b0ffd0-3671-4ef6-8ad9-4ad622b9f829">SOP Class UID associated with the operation.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_48b50b56-2059-4edc-a62f-44107782b16f">Command Field</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8261f783-3a00-470f-9ab6-dfd76b177358">(0000,0100)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0a2d47e8-4332-4a4d-a04b-fed50b568644">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a0bf5ff6-61bf-4113-ac40-c2c1e22d07d4">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5af61ef5-6d51-45cd-ba95-4da28f61d3ad">This field distinguishes the DIMSE-C operation conveyed by this Message. The value of this field shall be set to 8010H for the C-GET-RSP Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_19fed2d1-cdfa-432a-9ffd-0fe4a1eac73a">Message ID Being Responded To</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_dcad7e5d-9e61-42f7-b555-9969da546d1a">(0000,0120)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5f4077b5-5f20-4816-a4c9-3103697149ab">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_99dcd9ae-6783-4d7e-9063-c08e18272c6c">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_ffca911b-d882-4bbe-8631-b4bb08228e83">Shall be set to the value of the Message ID (0000,0110) field used in associated C-GET-RQ Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_12b2ab25-38e6-4848-bb95-e727036c1ee7">Command Data Set Type</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_780f3249-8c3e-4556-b512-91a287eba485">(0000,0800)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7d2bf4ea-294a-45e5-b184-da1e75f8a052">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d198f699-34db-48e9-aa1a-a373c4ab4572">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5d64faeb-ce94-45b6-bc02-93a25997feb8">This field indicates if a Data Set is present in the Message. This field shall be set to the value of 0101H (Null) if no Data Set is present; any other value indicates a Data Set is included in the Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_cced49eb-80e9-4daa-9b2e-9bfd08ecbfa6">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_26dd2ce6-93f0-4931-8eaa-6fb13a1a4dd1">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_91fe549a-b912-4a79-b92f-bd1652188bdb">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2ee40221-ff47-45e8-a4a9-90b5bd19a037">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1a4d9693-4d05-4539-b1ae-a7629e71961d">The value of this field depends upon the status type. <xref linkend="chapter_C" xrefstyle="template:Annex %n"/> defines the encoding of the status types defined in the service definition.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c4592b42-af3e-4cd0-8b88-d858f9f572c8">Number of Remaining Sub-operations</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a9139d27-24f8-49d9-aad1-046f742c7596">(0000,1020)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f6dda4a6-7398-482e-8c18-888981e8a921">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e4f36e82-0102-44c5-9a2e-5c791f91c0b8">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_49919401-4daa-48a5-9686-dde2a75f2e60">The number of remaining C-STORE sub-operations to be invoked for this C-GET operation.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f8fc96bd-a584-45bc-bff3-56db874a3336">Number of Completed Sub-operations</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_17aabfae-11b8-4ba5-afd0-066476f8c8dd">(0000,1021)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d1d33843-dd6f-4698-8f6f-d0f79b2f80bc">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_738f2430-3fb4-46a6-ab07-f81521e498eb">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a6f326b9-2d06-4660-82a4-0da9fcf41eb7">The number of C-STORE sub-operations invoked by this C-GET operation that have completed successfully.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6fac74aa-0104-4096-a112-48aa7d4c257c">Number of Failed Sub-operations</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b4b3ae6b-9cd9-4519-87f4-925f394b947c">(0000,1022)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f661a85f-04a3-481b-8d32-5328a1c02c20">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_95dbebc1-5ffc-44c7-a129-13b2589f10d2">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1d639433-1255-464e-b9f5-ef4e633f6f95">The number of C-STORE sub-operations invoked by this C-GET operation that have failed.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a328f3fd-dd1a-4d52-a557-de3b085fb52f">Number of Warning Sub-operations</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f9235aa7-e052-41cc-9c95-690ed3bc8560">(0000,1023)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_20cf1f17-bcbc-4690-bf0c-87f20caf3e3c">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_48ec6053-3609-4fe6-924d-44459c75f68f">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0497a642-bac4-417f-8117-c11a443706ac">The number of C-STORE sub-operations invoked by this C-GET operation that generated warning responses.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d6281c5c-86fa-4aeb-aa00-54310b686449">Identifier</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_16236bb7-1a17-4416-a19b-b202a08b8c8f">(no tag)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ed23d53d-29eb-4a0b-9447-d2499e03e990">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_62453379-82b6-4a1c-8be5-3672a647560c">-</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d936ff99-12f1-41fa-ac1f-6f4871648415">A Data Set that encodes the Identifier that was matched. See <xref linkend="sect_9.1.3.1.5" xrefstyle="select: label"/>.</para>
      </td>
    </tr>
    </tbody>
  </table>
  <note>
    <para xml:id="para_14e966dd-dfd3-4484-ab84-af4f4202c201">The list of Attributes allowed and the rules that define the usage of the Identifier are specified in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>.</para>
  </note>
  </section>
<section label="9.3.3.3" status="4" xml:id="sect_9.3.3.3">
    <title>C-CANCEL-GET-RQ</title>
  
  <para xml:id="para_7d2d07cd-1fd2-4af2-9336-456000940b68">The C-CANCEL-GET-RQ Message contains fields as defined in <xref linkend="table_9.3-8" xrefstyle="select: label"/>. Each field shall conform to DICOM encoding and Value Representation as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>. Fields are required as specified in the C-GET service definition unless otherwise noted in <xref linkend="table_9.3-8" xrefstyle="select: label"/>. Fields not specified in the C-GET service definition but present in <xref linkend="table_9.3-8" xrefstyle="select: label"/> are required by the DIMSE-C protocol.</para>
    <table frame="box" label="9.3-8" rules="all" xml:id="table_9.3-8">
    <caption>C-CANCEL-GET-RQ Message Fields</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_dd339936-13c0-4e0f-ba44-98efb00b3af0">
          <emphasis role="bold">Message Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_3b838e77-d2b2-46db-a4d9-b439ae674e7b">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_4a70ff06-0d96-4250-9547-6ca83fb2834f">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_873ba7bb-b28d-48d3-9ab4-54b558ee8f21">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_c6acf9a4-d643-480a-8ab3-ecdb8093e93b">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d7d95ab8-55a9-4cf2-8ab2-1eb5889dc35e">Command Group Length</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8ebffeaf-31cb-4976-a62b-64b02188ea07">(0000,0000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d21c33fe-cd68-4769-95d0-223d37f49695">UL</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_67e1947e-f4cd-45f0-94ba-e569961cbb6e">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b6366900-c853-4e6d-8a55-a32284018542">The even number of bytes from the end of the value field to the beginning of the next group.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6eaa7556-49bc-4c2b-a64f-5380ccbdf0c4">Command Field</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9c0dfdb9-280b-40fd-a347-acdc653b69ad">(0000,0100)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5eabec13-ec4b-40cd-ae03-5a4d266bf9b1">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b2cd731f-f434-4999-b8b2-a998012f5172">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f012a793-ed4e-486b-b2dc-1e36893970f3">This field distinguishes the DIMSE-C operation conveyed by this Message. The value of this field shall be set to 0FFFH for the C-CANCEL-GET-RQ Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_4e2e9008-7f72-4480-9372-5beb21ca00e6">Message ID Being Responded To</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f04fbd9b-45e4-4728-bd22-bc6551bab65d">(0000,0120)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_812eec46-9439-4519-a009-ba975a8343d7">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_180cbb98-87c5-415a-92c3-a16c49db35d9">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3cc02f74-2543-4e8c-afba-e76bb1880d54">Shall be set to the value of the Message ID (0000,0110) field used in associated C-GET-RQ Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_96750b96-75b7-4f6b-a162-c3d0cf4f4575">Command Data Set Type</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_862a7c90-0b59-4363-a685-f1f6ea981ac9">(0000,0800)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_03085ac5-cf41-46d4-9c31-713a9f110df1">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_be9b0d72-ed19-40fa-8b76-148a1abde3f0">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a519ed2b-2476-4b68-8d96-1973cc70a0ba">This field indicates that no Data Set is present in the Message and shall be set to a value of 0101H.</para>
      </td>
    </tr>
    </tbody>
  </table>
  </section>
<section label="9.3.3.4" status="4" xml:id="sect_9.3.3.4">
    <title>C-GET Protocol Procedures</title>
  
  <para xml:id="para_16e8a08b-ec2e-4f2b-9797-ac2e803dc6e8">The C-GET procedures are initiated by the Invoking DIMSE Service User issuing a C-GET Request primitive. On receipt of the C-GET Request primitive the DIMSE-C protocol machine shall:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_79450da9-f2ae-432c-b509-b527e19b6fce">construct a Message conveying the C-GET-RQ</para>
</listitem>
  <listitem>
<para xml:id="para_ac02c881-4aba-4202-baf5-b6494f08649b">send the Message using the P-DATA request service (see 8.1).</para>
</listitem>
</itemizedlist>
  <para xml:id="para_d41652f0-1dba-442e-b9c9-21f2a0510f49">On receipt of a Message conveying a C-GET-RQ the DIMSE-C protocol machine shall issue a C-GET indication primitive to the Performing DIMSE Service User.</para>
  <para xml:id="para_f461afe6-f692-41f3-b197-75db19e05f2d">The DIMSE-C protocol machine shall:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_21acbcb0-9386-4771-917e-6f855639d86f">accept zero or more C-GET response primitives containing the status of Pending, issued by the Performing DIMSE Service User, followed by a single C-GET response primitive containing the final status</para>
</listitem>
  <listitem>
    <para xml:id="para_03506739-e162-4910-bdb4-59753e2bc38a">for each C-GET response primitive containing the Pending status the DIMSE-C protocol machine shall:</para>
    <orderedlist numeration="loweralpha">
      <listitem>
<para xml:id="para_b18835ec-d02f-4e79-97cc-1c496500be2b">construct a Message conveying the (Pending) C-GET-RSP</para>
</listitem>
      <listitem>
<para xml:id="para_e6bce3db-9adb-45e1-a031-7017a484d1f3">send the Message using the P-DATA request service (see 8.1)</para>
</listitem>
    </orderedlist>
  </listitem>
  <listitem>
    <para xml:id="para_52483e07-52c7-4e44-a724-d0c87b249fc3">for the C-GET response primitive containing the final status the DIMSE-C protocol machine shall:</para>
    <orderedlist numeration="loweralpha">
      <listitem>
<para xml:id="para_2114ae26-b3e5-4af9-9f02-a43a6789ee09">construct a Message conveying the (final) C-GET-RSP</para>
</listitem>
      <listitem>
<para xml:id="para_6814d379-275b-4a0a-a199-04aeb85986dd">send the Message using the P-DATA request service (see 8.1)</para>
</listitem>
    </orderedlist>
  </listitem>
</itemizedlist>
  <note>
    <para xml:id="para_af356773-ef4d-45d4-b303-37db283d37ea">The C-GET indication primitive initiates a sub-operation identical to the C-STORE operation. However, for the C-STORE sub-operation the DIMSE Service Users switch their invoking and performing roles (i.e., the Invoking DIMSE Service User becomes the Performing DIMSE Service User, etc.).</para>
  </note>
  <para xml:id="para_1fa8dea9-4564-45c5-b573-2723466b3b82">On receipt of a Message conveying a C-GET-RSP the DIMSE-C protocol machine shall:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_64a71b60-06ac-402c-b54e-88741aa65ad7">if the Message indicates the status of Pending, issue a C-GET confirmation primitive to the Invoking DIMSE Service User with a Pending status</para>
</listitem>
  <listitem>
<para xml:id="para_7ad5d429-3960-4037-bd9e-1a84ffc90efd">if the Message indicates a final status, issue a C-GET confirmation primitive to the Invoking DIMSE Service User with a final status, thus completing the C-GET procedure</para>
</listitem>
</itemizedlist>
  <note>
    <para xml:id="para_d4e7f81f-9cab-403d-93a6-ad7b9820155f">The C-GET procedures can be canceled at any time by the Invoking DIMSE Service User. This is accomplished by the Invoking DIMSE Service User issuing a C-CANCEL Request primitive.</para>
  </note>
  <para xml:id="para_39223cf3-72ae-4a39-b151-d403394d296e">The Performing DIMSE Service User may return a C-GET-RSP with the status of Failed or Refused before the complete C-GET-RQ request Message has been completely transmitted by the Invoking DIMSE Service User (this is called an early failed response). Upon receipt of this Failed or Refused C-GET-RSP the Invoking DIMSE Service User may terminate the Message before it is completely sent (i.e., set the Last Fragment bit to 1 in a Data PDV for this Message, see <xref linkend="chapter_F" xrefstyle="template:Annex %n"/>). Following this, it may invoke another operation or notification. It is a protocol violation for an Invoking DIMSE Service User to set the Last Fragment bit to 1 before a C-GET-RQ Message has been completely transmitted if it has not received a Failed or Refused C-GET-RSP to that request.</para>
  <note>
    <para xml:id="para_df02ae99-738e-47ac-a900-0466bc3dc87a">When an Association is operating in asynchronous mode, it is possible for an Invoking DIMSE Service User to transmit several Messages before a response. Therefore, while sending a Message it may receive a response to a previously transmitted Message. In this case this response is not an early failed response because the related Message has already been sent.</para>
  </note>
  </section>
</section>
<section label="9.3.4" status="3" xml:id="sect_9.3.4">
    <title>C-MOVE Protocol</title>
  
    <para xml:id="para_84d7822b-2305-48be-8ff4-7effec5aef55">The information necessary for the C-MOVE Request and C-MOVE Indication DIMSE-C primitives are conveyed in the C-MOVE-RQ Message. The information necessary for the C-MOVE response and confirmation DIMSE-C primitives are conveyed in the C-MOVE-RSP Message. The information necessary for the C-MOVE Cancel request and Cancel indication primitives are conveyed in the C-CANCEL-MOVE-RQ Message.</para>
  <section label="9.3.4.1" status="4" xml:id="sect_9.3.4.1">
    <title>C-MOVE-RQ</title>
  
  <para xml:id="para_bd38a17f-edf5-4aaf-aa74-c3e4140c11c3">The C-MOVE-RQ Message contains fields as defined in <xref linkend="table_9.3-9" xrefstyle="select: label"/>. Each field shall conform to DICOM encoding and Value Representation as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>. Fields are required as specified in the C-MOVE service definition unless otherwise noted in <xref linkend="table_9.3-9" xrefstyle="select: label"/>. Fields not specified in the C-GET-MOVE service definition but present in <xref linkend="table_9.3-9" xrefstyle="select: label"/> are required by the DIMSE-C protocol.</para>
    <table frame="box" label="9.3-9" rules="all" xml:id="table_9.3-9">
    <caption>C-MOVE-RQ Message Fields</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_d20177fc-99d1-4779-b5e1-eaac29505229">
          <emphasis role="bold">Message Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_bdb2a329-62ca-4b4d-8618-7a1103f1c259">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_fc6c9afb-9239-4562-aec7-2f78cb3edcca">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_5c70d511-878d-4733-b009-db01ac2f6921">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_60e9ba32-2a29-4ff2-b13b-f4f68c56ba24">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f5a86fa2-9457-4650-abb6-5f31075fc69c">Command Group Length</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_faed338d-508e-435b-b196-d7c5573f81b2">(0000,0000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ac791a1d-2a9c-4227-8da6-6468d2775410">UL</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_3b8de319-1794-4067-a426-ba898690f428">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f2ed1028-1298-4145-8f5f-d49439796a4a">The even number of bytes from the end of the value field to the beginning of the next group.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_20967a8e-3682-44a6-a183-f052969d576b">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_82708a0f-87e6-4a60-8261-0ad3c2d1e080">(0000,0002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0b3d1582-0493-4108-a78a-691bd9ff9c16">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_bfa0a4e4-27f3-432f-aaf4-83d3456a9083">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a194fbed-1a0e-4292-a2fe-326279a248e0">SOP Class UID associated with this operation.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_20f34f9d-67b0-44a0-82a6-71063da4f845">Command Field</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_09b69c27-e8de-42a6-88a0-5bdf30531cfa">(0000,0100)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b6b95e6c-7b1c-4a89-9241-9b3ba40c6a26">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_18987859-f6f4-4911-a5fb-575f1f44ad7d">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e76aa8ce-f153-4989-91af-a4c00ba5e7ef">This field distinguishes the DIMSE-C operation conveyed by this Message. The value of this field shall be set to 0021H for the C-MOVE-RQ Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_890445bb-3eff-4ef1-b192-420662521302">Message ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1fd74a8a-5091-4e68-adf3-d8edf12e7887">(0000,0110)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e234b6be-9e08-4cd6-971e-ab8f9142305f">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_267925c7-a3d4-4e38-8745-9e100a8192ce">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_87755294-8a93-4d34-b963-9ca77b2eea98">Implementation-specific value that distinguishes this Message from other Messages.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_22c80b99-506b-4b90-8984-fea6c6fcadd6">Priority</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e059d554-0e4c-41a9-aebe-353c359fe1b1">(0000,0700)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9c5193bf-a72a-4c99-802a-9a1186798d97">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_245278bb-22ef-486c-866e-144240044a02">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1534aafc-6d40-46ab-8a4a-de29f9c93c42">The priority shall be set to one of the following values:</para>
        <para xml:id="para_02618b6c-77ed-4429-9487-6a280859e149">LOW = 0002H</para>
        <para xml:id="para_0f6929ce-6340-44b2-914f-071ecbd76b37">MEDIUM = 0000H</para>
        <para xml:id="para_59ac3c52-e155-42cb-bf94-de8e90b355f0">HIGH = 0001H</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a7b30b8a-609a-4f02-bb58-15f163df69bf">Command Data Set Type</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_832b2cc0-517a-4aac-b810-b736a5633ff6">(0000,0800)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4bf32d3c-003c-41e4-ad9e-b0d17799f0d8">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e3edc6e4-e0b2-4e1d-bd31-9a12b8abbb91">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_887a3ba1-fef6-4639-94e1-439445e83deb">This field indicates that a Data Set is present in the Message. It shall be set to any value other than 0101H (Null).</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6a71d7ae-4a75-42f0-8efa-7fc612df4fc7">Move Destination</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_81e96fe1-3572-4d90-9dab-b4f51cc91ee6">(0000,0600)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8a3477d4-9e13-42a9-bdf6-786c3d2958c8">AE</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_00ca9df3-22ad-4783-ab90-7185eb9adb84">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_97d8e39e-4498-4022-af71-b5436578e9f3">Shall be set to the DICOM AE Title of the destination DICOM AE to which the C-STORE sub-operations are being performed.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_34930d30-5408-4fed-828c-a148d2bb1f9e">Identifier</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_fa1081d8-d8eb-499c-981f-16ec032628c0">(no tag)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_3efbc70c-e2fc-4b42-89d3-fa27f8d64777">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a9b826bd-ea6a-40bc-93c8-4bef18c3a64d">-</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b03c77fb-d9c7-40bf-844e-b3cb65435fbe">A Data Set that encodes the Identifier to be matched. See <xref linkend="sect_9.1.4.1.6" xrefstyle="select: label"/>.</para>
      </td>
    </tr>
    </tbody>
  </table>
  <note>
    <para xml:id="para_105ee44a-61c8-4a0a-8e09-a76b37ed5590">Implementations that require compatibility to previous versions of this Standard must set the Command Data Set Type (0000,0800) Field to 0102H (Identifier).</para>
  </note>
  </section>
<section label="9.3.4.2" status="4" xml:id="sect_9.3.4.2">
    <title>C-MOVE-RSP</title>
  
  <para xml:id="para_047b015c-17fe-4bfe-8c29-ea86ffbcf1b4">The C-MOVE-RSP Message contains fields as defined in <xref linkend="table_9.3-10" xrefstyle="select: label"/> and in <xref linkend="chapter_C" xrefstyle="template:Annex %n"/>. Each field shall conform to DICOM encoding and Value Representation as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>. Fields are required as specified in the C-MOVE service definition unless otherwise noted in <xref linkend="table_9.3-10" xrefstyle="select: label"/>. Fields not specified in the C-MOVE service definition but present in <xref linkend="table_9.3-10" xrefstyle="select: label"/> are required by the DIMSE-C protocol.</para>
    <table frame="box" label="9.3-10" rules="all" xml:id="table_9.3-10">
    <caption>C-MOVE-RSP Message Fields</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_5f5f94e9-e37f-4f64-baad-a782237b1ffc">
          <emphasis role="bold">Message Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_5196f554-6c7d-44bf-b7f7-b3799c5bc8d4">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_a7509284-8ac9-4171-bb14-6bb009888ee8">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_10eddd6a-b281-48b8-8d2e-ed711f41aa00">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_655485d2-03a6-4110-8365-847dd8ffec69">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_49eb9a11-a606-4a81-aeeb-6effed53695c">Command Group Length</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_97a4ac90-855c-462a-84f1-da4747bd74ea">(0000,0000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_34ae0ed4-a757-41a8-b795-dd77aaa7d1a0">UL</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a58aa77d-b102-4ac3-b06b-2e27582687ae">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9e19c0fa-e3ba-4867-8745-e37efc05f528">The even number of bytes from the end of the value field to the beginning of the next group.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9845dc78-f8ca-4949-9326-ddb37077d9ee">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_aea2e51d-46af-40b0-90c4-d3dc997c9ce9">(0000,0002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_96fe3632-5ea4-4cc1-8efd-d2917ea4219a">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_962e86fa-4e59-4df3-ae7c-af57c33a05f6">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f96baad1-6b11-426a-9f7d-3863f179c045">SOP Class UID associated with the operation.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_05e28b48-f609-4e62-9433-0638c3e02c4c">Command Field</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6f3e922c-8da6-46df-bd6d-3b773e52ed16">(0000,0100)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_796f99df-e470-4a93-b7f6-f6a48da690f6">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f2c6eec0-7ff2-4ba8-926d-2158bc824a9b">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_7b31421c-106a-4af7-bb9f-1215652be57b">This field distinguishes the DIMSE-C operation conveyed by this Message. The value of this field shall be set to 8021H for the C-MOVE-RSP Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1e0702a4-0f3e-4445-bd93-dab8da83aaf3">Message ID Being Responded To</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_fe7c4384-4d79-4086-8788-b734ebad0737">(0000,0120)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2105f025-109a-4b95-be43-bb5fc7341c3d">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_44366643-fd4c-4192-9cf2-65b8122f5190">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c738b73c-31c2-4a8d-b4f7-beee546b202f">Shall be set to the value of the Message ID (0000,0110) field used in associated C-MOVE Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_fc549ad7-31c4-4a7b-b767-398524838104">Command Data Set Type</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_dd84abaf-9232-4687-94f5-0d365cef0416">(0000,0800)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_41f1f2d4-4df8-4233-8825-4392625129eb">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f7baa143-302d-4d59-9b8a-e34f77c79ac8">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_8513a891-8862-4224-b2b6-915663357784">This field indicates if a Data Set is present in the Message. This field shall be set to the value of 0101H (Null) if no Data Set is present; any other value indicates a Data Set is included in the Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_918cd985-a4a0-4647-84ce-bc7a12b8ff03">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_87d387f1-b744-42a0-a976-21b44c381827">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a482c82b-f62f-4dfc-bb5a-c562fea2ddba">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4fce2401-6b63-4f10-aa71-b73f6d49b61b">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d6aa5ab3-9312-4ffb-a9bd-8ffbac155908">The value of this field depends upon the status type. <xref linkend="chapter_C" xrefstyle="template:Annex %n"/> defines the encoding of the status types defined in the service definition.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1e036a88-e897-45ff-a393-718f6cd72bc7">Number of Remaining Sub-operations</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6d6deb3f-c429-43d4-8dc5-f41211781b09">(0000,1020)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0823fae0-2544-4e2b-aadb-3f4faee3b231">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5722b983-3433-4ecd-a233-659ce452f628">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
          <para xml:id="para_41403a87-8efe-4006-921f-1c2220586368">The number of remaining C-STORE sub-operations to be invoked for this C-MOVE operation.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c6e3fec0-cdb0-4391-9bc4-9bc622067664">Number of Completed Sub-operations</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9055022a-4713-42ea-a578-63747a9ddbc8">(0000,1021)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6abcbf8d-df99-4b56-9a05-8c2ec700d396">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1d55d359-c2e8-4022-aa39-3150a7d445c3">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e8e42acb-8379-4e41-af5d-fc65fe0c359e">The number of C-STORE sub-operations invoked by this C-MOVE operation that have completed successfully.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b43cab53-63e1-4b59-a22f-5fd6faebb0f2">Number of Failed Sub-operations</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f55cfa01-8ce9-4f5d-9664-abd1ac99ea0e">(0000,1022)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6d2ab01d-fb84-4346-9060-24c3a3a863c3">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_bd37b157-93f5-4ec8-abd9-0fad778b0b1f">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_58145124-638a-44b8-88a0-42d94cf4300f">The number of C-STORE sub-operations invoked by this C-MOVE operation that have failed.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_bf7f0e31-769a-45db-bb8f-981bf5aa224b">Number of Warning Sub-operations</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_46fac9f9-e742-46e2-a736-38cfcd056f30">(0000,1023)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6deb18e3-0c02-41db-aef8-7dfc485e78a1">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4c9880af-ef19-4f17-a1c6-a3f4ac0f825b">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d270c984-a391-40f1-ac55-95704a7abcf5">The number of C-STORE sub-operations invoked by this C-MOVE operation that generated warning responses.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0da7401c-5ac2-4a1f-a898-1f4dc6023eaf">Identifier</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_81fe1bc8-25d3-49b4-947a-74bf42f4c9b3">(no tag)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_eb9c76c8-bdd2-4e58-8cb1-94180e8b084e">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7eae5c56-145f-49ea-8230-98a7030d31fc">-</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f0767baa-5a4d-4215-bd1d-c0ceba193a4a">A Data Set that encodes attributes providing status information about the C-MOVE operation. See <xref linkend="sect_9.1.4.1.6" xrefstyle="select: label"/>.</para>
      </td>
    </tr>
    </tbody>
  </table>
  </section>
<section label="9.3.4.3" status="4" xml:id="sect_9.3.4.3">
    <title>C-CANCEL-MOVE-RQ</title>
  
  <para xml:id="para_358a0d12-6311-4890-ac13-0d8198e58e39">The C-CANCEL-MOVE-RQ Message contains fields as defined in <xref linkend="table_9.3-11" xrefstyle="select: label"/>. Each field shall conform to DICOM encoding and Value Representation as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>. Fields are required as specified in the C-MOVE service definition unless otherwise noted in <xref linkend="table_9.3-11" xrefstyle="select: label"/>. Fields not specified in the C-MOVE service definition but present in <xref linkend="table_9.3-11" xrefstyle="select: label"/> are required by the DIMSE-C protocol.</para>
    <table frame="box" label="9.3-11" rules="all" xml:id="table_9.3-11">
    <caption>C-CANCEL-MOVE-RQ Message Fields</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_b948b5c4-3246-4b86-8266-ffe13405bd36">
          <emphasis role="bold">Message Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_f6b4fe3c-19e1-461c-af10-271ddb7767db">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_9a957a92-1617-41d4-91b7-5a88334c7a75">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_4f1adc0e-502a-44e5-ae09-3240c77ecf08">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_0f6f38fb-1e00-4f58-b896-fa6bdea288b8">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5dcbfd6d-dc68-4e0e-bf2c-f5a8f500da40">Command Group Length</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9d93136d-11cb-4fc4-9229-5f32f76b6fdd">(0000,0000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d4b2deb9-7267-4dc3-8adc-e8a275f58a08">UL</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_702ddf23-6728-4ba9-9031-017cfd622936">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_044c63df-1c2f-46a8-ad05-1640d0f17098">The even number of bytes from the end of the value field to the beginning of the next group.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_8ab9eb4b-1f32-4a65-979d-70b19eaad740">Command Field</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4b185668-e5ee-4765-a3ed-14ea589888de">(0000,0100)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_10f5cc32-c3fd-4611-80b0-b9bd9e52f9f7">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_539144ef-9e7c-423e-b0d5-fa900043f196">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_ef12958e-808c-489f-978f-aeb20053270a">This field distinguishes the DIMSE-C operation conveyed by this Message. The value of this field shall be set to 0FFFH for the C-CANCEL-MOVE-RQ Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d1c0ad57-0ac4-4d83-a123-82c28baa03b3">Message ID Being Responded To</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1cae89ce-426b-40ae-8d17-025da0e44d53">(0000,0120)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_503c5bfd-57ce-424a-ada0-fc573ad11815">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_60dec259-2ff1-4c4c-a025-35beadf789c8">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_593bc413-ada2-43ff-ba3a-0bc6babb2c06">Shall be set to the value of the Message ID (0000,0110) field used in associated C-MOVE-RQ Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e240f8e7-e84b-452e-82b0-19d920dd7d8a">Command Data Set Type</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_04208465-a8c4-4898-9b5b-b44d7bbcca30">(0000,0800)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_179a4432-ddeb-4793-9e7e-ce4dd35ad238">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0cbe72d9-20e9-4b4f-a921-a2e7913e3eac">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_7b783e07-0dcc-44da-9b7f-fd2f04e29a98">This field indicates that no Data Set is present in the Message and shall be set to a value of 0101H.</para>
      </td>
    </tr>
    </tbody>
  </table>
  </section>
<section label="9.3.4.4" status="4" xml:id="sect_9.3.4.4">
    <title>C-MOVE Protocol Procedures</title>
  
  <para xml:id="para_d90c4d40-03fb-46cd-960c-d7bdf1a5a146">The C-MOVE procedures are initiated by the Invoking DIMSE Service User issuing a C-MOVE Request primitive. On receipt of the C-MOVE Request primitive the DIMSE-C protocol machine shall:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_9de0edd6-6985-4791-940d-30348e1c18c1">construct a Message conveying the C-MOVE-RQ</para>
</listitem>
  <listitem>
<para xml:id="para_1df8271a-cac2-435b-a016-d2081ee7d667">send the Message using the P-DATA request service (see 8.1)</para>
</listitem>
</itemizedlist>
  <para xml:id="para_ff2d8d13-e56d-473e-b954-0f6d1febea09">On receipt of a Message conveying a C-MOVE-RQ the DIMSE-C protocol machine shall issue a C-MOVE indication primitive to the Performing DIMSE Service User.</para>
  <para xml:id="para_b48198da-e942-40e6-8638-96f38ab0fcb0">The DIMSE-C protocol machine shall:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_c08add66-e7e8-4be3-a849-3bee14272c41">accept zero or more C-MOVE response primitives containing the status of Pending, issued by the Performing DIMSE Service User, followed by a single C-MOVE response primitive containing the final status</para>
</listitem>
  <listitem>
    <para xml:id="para_b58f1e04-8844-434f-96cb-fefe3f9c1f48">for each C-MOVE response primitive containing the Pending status the DIMSE-C protocol machine shall:</para>
    <orderedlist numeration="loweralpha">
      <listitem>
<para xml:id="para_cff1c636-cf11-4695-9a34-efb498775d20">construct a Message conveying the (Pending) C-MOVE-RSP</para>
</listitem>
      <listitem>
<para xml:id="para_4736791d-8703-43e2-b32e-4f7f9bf1a8e1">send the Message using the P-DATA request service (see 8.1)</para>
</listitem>
    </orderedlist>
  </listitem>
  <listitem>
    <para xml:id="para_44fad1ba-9b7c-4c5d-b8bb-6641f77cc095">for the C-MOVE response primitive containing the final status the DIMSE-C protocol machine shall:</para>
    <orderedlist numeration="loweralpha">
      <listitem>
<para xml:id="para_0c6ce495-cd0f-4eb1-8aa1-ac954a40adb4">construct a Message conveying the (final) C-MOVE-RSP</para>
</listitem>
      <listitem>
<para xml:id="para_c680e91a-a27d-4289-9d27-a0924ee0a090">send the Message using the P-DATA request service (see 8.1)</para>
</listitem>
    </orderedlist>
  </listitem>
</itemizedlist>
  <note>
    <para xml:id="para_943ab1d5-56a0-4f13-b9ad-6b2ec76182e7">The C-MOVE indication primitive initiates a sub-operation identical to the C-STORE operation.</para>
  </note>
  <para xml:id="para_4fcfbf69-e014-417d-b9e7-7756e0038a9b">On receipt of a Message conveying a C-MOVE-RSP the DIMSE-C protocol machine shall:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_3cc3f347-b3df-44e8-b279-331e8eb3f8be">if the Message indicates the status of Pending, issue a C-MOVE confirmation primitive to the Invoking DIMSE Service User with a Pending status;</para>
</listitem>
  <listitem>
<para xml:id="para_ce1ac4e4-bb04-4819-8fea-61260b037ac9">if the Message indicates a final status, issue a C-MOVE confirmation primitive to the Invoking DIMSE Service User with a final status, thus completing the C-MOVE procedure</para>
</listitem>
</itemizedlist>
  <note>
    <para xml:id="para_cbfef3ce-f09c-4863-ba4a-11acd2797815">The C-MOVE procedures can be canceled at any time by the Invoking DIMSE Service User. This shall be accomplished by the Invoking DIMSE Service User issuing a C-CANCEL Request primitive.</para>
  </note>
  <para xml:id="para_9b39a2b2-2e2c-4b0a-8e29-a63c4c0d794d">The Performing DIMSE Service User may return a C-MOVE-RSP with the status of Failed or Refused before the complete C-MOVE-RQ request Message has been completely transmitted by the Invoking DIMSE Service User (this is called an early failed response). Upon receipt of this Failed or Refused C-MOVE-RSP the Invoking DIMSE Service User may terminate the Message before it is completely sent (i.e., set the Last Fragment bit to 1 in a Data PDV for this Message, see <xref linkend="chapter_F" xrefstyle="template:Annex %n"/>). Following this, it may invoke another operation or notification. It is a protocol violation for an Invoking DIMSE Service User to set the Last Fragment bit to 1 before a C-MOVE-RQ Message has been completely transmitted if it has not received a Failed or Refused C-MOVE-RSP to that request.</para>
  <note>
    <para xml:id="para_ef6a6264-3cbd-48aa-9465-8698303c78c8">When an Association is operating in asynchronous mode, it is possible for an Invoking DIMSE Service User to transmit several Messages before a response. Therefore, while sending a Message it may receive a response to a previously transmitted Message. In this case this response is not an early failed response because the related Message has already been sent.</para>
  </note>
  </section>
</section>
<section label="9.3.5" status="3" xml:id="sect_9.3.5">
    <title>C-ECHO Protocol</title>
  
    <para xml:id="para_fb7b70b6-a97f-4ac3-9063-ca24305fcda3">The information necessary for the C-ECHO Request and C-ECHO Indication DIMSE-C primitives are conveyed in the C-ECHO-RQ Message. The information necessary for the C-ECHO response and confirmation DIMSE-C primitives are conveyed in the C-ECHO-RSP Message.</para>
  <section label="9.3.5.1" status="4" xml:id="sect_9.3.5.1">
    <title>C-ECHO-RQ</title>
  
  <para xml:id="para_b7f4a1a5-3c38-49c4-a807-2404aecd2ea1">The C-ECHO-RQ Message contains fields as defined in <xref linkend="table_9.3-12" xrefstyle="select: label"/>.
      Each field shall conform to DICOM encoding and Value Representation as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>.
      Fields are required as specified in the C-ECHO service definition unless otherwise noted in <xref linkend="table_9.3-12" xrefstyle="select: label"/>.
      Fields not specified in the C-ECHO service definition but present in <xref linkend="table_9.3-12" xrefstyle="select: label"/> are required by the DIMSE-C protocol.</para>
    <table frame="box" label="9.3-12" rules="all" xml:id="table_9.3-12">
    <caption>C-ECHO-RQ Message Fields</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_2ce4fbb0-ab1c-42a8-87c2-e3e1b95476a5">
          <emphasis role="bold">Message Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_9c459669-abc4-4766-a434-6cb3ea27dbc8">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_aeaf885d-bb92-4e70-886a-7c8d303e5908">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_f372df36-686b-4b33-88c4-2f06c77d81e5">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_bbf6191e-73d0-4b7d-bb6e-c8b06c1cc4d1">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_add4afb2-5a67-4c1a-b328-2d0af434d2ae">Command Group Length</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5d19aac7-7095-4dad-9e93-b12392df817b">(0000,0000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8b8f231b-9f03-4a15-9f60-134d614c6785">UL</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_14b42066-daf3-468d-9967-ab9e4621494d">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3c17ba20-fa8a-4ba1-98c8-edb84f903571">The even number of bytes from the end of the value field to the beginning of the next group.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5658f220-a500-415b-bec0-228311dd260f">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_36049e8f-58c4-4093-983c-58cf2c5c844d">(0000,0002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_84b85e83-65ee-4d00-bb21-23e731e3f10e">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b98c2a45-8d63-4cc6-8b0c-607895f5522e">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_81b8cfd1-1a03-48b0-a89b-41bdd36d554c">SOP Class UID associated with this operation.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_61baf85a-dc43-4ddd-81a1-ec3f8d0bc680">Command Field</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b10634cc-f48c-4f4c-8f14-6b4a368230e3">(0000,0100)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_bbca1594-a2f1-4781-9d44-0a622f9de9e0">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4cd11d1f-c6e3-44ce-93cd-47ea84e54265">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_90ae5f78-f702-49b3-bef1-c13141f55865">This field distinguishes the DIMSE-C operation conveyed by this Message. The value of this field shall be set to 0030H for the C-ECHO-RQ Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9831edb2-d32b-4b67-9f1d-3712175c8d8d">Message ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_47e07d52-babf-4baf-93f2-5776f23a9251">(0000,0110)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_81cd5d68-c78a-4dc2-9c22-be32cf581ac1">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_43ecf291-be72-4db0-95ea-d0a935c1e37f">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e3fd1448-128b-4994-83b8-083ad6255985">Implementation-specific value that distinguishes this Message from other Messages.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_fc93ccc8-5a04-4164-aa13-aebf5187635b">Command Data Set Type</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b11bab49-73ae-4666-853c-e8ffdb57f31e">(0000,0800)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_84829d5a-7c87-4d34-9f6d-94c84070d022">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f7be0c35-26d4-4e46-b2bd-6619aa419ee3">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a15dc20e-8766-40a6-8d4e-432349859fdf">This field indicates that no Data Set is present in the Message and shall be set to a value of 0101H.</para>
      </td>
    </tr>
    </tbody>
  </table>
  </section>
<section label="9.3.5.2" status="4" xml:id="sect_9.3.5.2">
    <title>C-ECHO-RSP</title>
  
  <para xml:id="para_8a1ac252-13ca-47ab-a325-7aa67924dfd9">The C-ECHO-RSP Message contains fields as defined in <xref linkend="table_9.3-13" xrefstyle="select: label"/> and in <xref linkend="chapter_C" xrefstyle="template:Annex %n"/>. Each field shall conform to DICOM encoding and Value Representation as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>. Fields are required as specified in the C-ECHO service definition unless otherwise noted in <xref linkend="table_9.3-13" xrefstyle="select: label"/>. Fields not specified in the C-ECHO service definition but present in <xref linkend="table_9.3-13" xrefstyle="select: label"/> are required by the DIMSE-C protocol.</para>
    <table frame="box" label="9.3-13" rules="all" xml:id="table_9.3-13">
    <caption>C-ECHO-RSP Message Fields</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_cf5dc574-6e6e-41de-b0ee-f6c5e66b0105">
          <emphasis role="bold">Message Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_95bcf5f7-9bb1-4e5a-a124-dc65770c7cc4">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_f317f2fb-4956-4872-8a1e-847b0850353a">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_1dbe47af-883b-4d59-bae5-4e1bd6adf245">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_c29566ca-d1e7-4d96-91a5-902e5cdeb86c">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6c85ee3c-ffd6-4834-893b-8f0ae45d304a">Command Group Length</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_cb2a3e54-b082-49da-b866-2d19e7049a3c">(0000,0000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_51dc89c3-6541-45b3-ac17-1e49d59e9d14">UL</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_3e05bc71-dbea-4c9c-b9cb-668af8914f2a">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_cb0fc5b5-b074-40fb-bc6b-50b8289a541a">The even number of bytes from the end of the value field to the beginning of the next group.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_81b24233-fed2-4780-afa5-f335a3fc3d3c">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_21dced28-d5a6-4ffe-8557-40c302bac05f">(0000,0002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f862633f-fb27-42f9-85d2-84b189ead4d1">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_16cb10d7-a23b-48b8-a456-817cda020f8d">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6e879209-13d9-4375-8ca0-bbab30722536">SOP Class UID associated with the operation.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_dc0124b1-d931-44ff-85da-a4f2343fbc8d">Command Field</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_3c7addbf-fdf6-4d13-9fe9-c563b25b46b5">(0000,0100)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d520458d-f51e-42ae-bd9e-2de4724e980a">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_63131c80-02da-48b4-b277-59ff302dd53e">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_10f2645b-57b2-42ff-8f82-678093b3cdae">This field distinguishes the DIMSE-C operation conveyed by this Message. The value of this field shall be set to 8030H for the C-ECHO-RSP Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d8c00ecb-d57c-4576-94bf-363683a847aa">Message ID Being Responded To</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_dbed42a5-1d4e-457c-aac6-71579d719829">(0000,0120)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_3e7d5f84-bb4b-4ecf-82c6-5a311a131397">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d60150dd-51dc-468b-abcf-c5cb9beb3698">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5d6c0b1e-768b-4f95-b9e2-cc82a7695a33">Shall be set to the value of the Message ID (0000,0110) field used in associated C-ECHO-RQ Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b68fce44-ab0b-4c9e-8077-f86f4e789395">Command Data Set Type</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b468c309-4cdc-4cf3-9fc7-51f0174c6cbd">(0000,0800)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_79752315-5756-4b33-8f08-6d189f441821">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e6c5c773-01fe-40b4-9c4f-7600fd5024cf">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_424e0cf6-57f9-468b-a7b7-61fd603850d5">This field indicates that no Data Set is present in the Message and shall be set to a value of 0101H.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_40a292ce-11a2-4f19-bef0-11bec8b65542">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_59cdb946-9317-4436-884c-567de2602858">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_79f06004-ad1d-409e-8a60-282e5fd50586">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1f421b88-24be-4b03-a7aa-526e1e38f20d">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9bf70e1e-fa0a-475f-8c65-0bc57d38d8f4">Indicates the status of the response. It shall have a value of Success.</para>
      </td>
    </tr>
    </tbody>
  </table>
  </section>
<section label="9.3.5.3" status="4" xml:id="sect_9.3.5.3">
    <title>C-ECHO Protocol Procedures</title>
  
  <para xml:id="para_19241edf-a585-4629-a0c6-ded8b538881f">The C-ECHO procedures are initiated by the Invoking DIMSE Service User issuing a C-ECHO Request primitive. On receipt of the C-ECHO Request primitive the DIMSE-C protocol machine shall:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_53e80872-3e2e-4c9a-a68d-f013c38149bc">construct a Message conveying the C-ECHO-RQ</para>
</listitem>
  <listitem>
<para xml:id="para_1e12ccaf-265b-4dbd-8d21-6cec6dc1cb37">send the Message using the P-DATA request service (see 8.1)</para>
</listitem>
</itemizedlist>
  <para xml:id="para_54471e04-3870-4885-baac-01e3b03358bf">On receipt of a Message conveying a C-ECHO-RQ the DIMSE-C protocol machine shall issue a C-ECHO indication primitive to the Performing DIMSE Service User.</para>
  <para xml:id="para_e53f1d6a-8707-4250-ac71-f7a756d2ecab">On receipt of a C-ECHO response primitive, issued by the Performing DIMSE Service User, the DIMSE-C protocol machine shall:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_0565fac9-cd01-4c26-87b1-daf92d6cb367">construct a Message conveying the C-ECHO-RSP</para>
</listitem>
  <listitem>
<para xml:id="para_d7dc17b6-ba58-41c3-afa0-81aec8ab4907">send the Message using the P-DATA request service (see 8.1)</para>
</listitem>
</itemizedlist>
  <para xml:id="para_970fb0c8-0be9-48cd-9e3e-fc6d30ec5789">On receipt of a Message conveying a C-ECHO-RSP the DIMSE protocol machine shall issue a C-ECHO confirmation primitive to the Invoking DIMSE Service User, thus completing the C-ECHO procedure.</para>
  </section>
</section>
</section>
</chapter>
<chapter label="10" status="1" xml:id="chapter_10">
    <title>DIMSE-N</title>
  
  <section label="10.1" status="2" xml:id="sect_10.1">
    <title>Services</title>
  
  <para xml:id="para_0a03c544-27cb-4a23-914e-97c488bc9ddf">The following sections describe the DIMSE-N Services. The behavior of these services is also described in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>. The Affected SOP Class UID in the DIMSE-N command need not match the SOP Class UID in the Presentation Context negotiated for the association over which the DIMSE-N command has been sent. <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/> specifies which combinations are valid.</para>
  <section label="10.1.1" status="3" xml:id="sect_10.1.1">
    <title>N-EVENT-REPORT Service</title>
  
  <para xml:id="para_0aa74a97-5bd6-44fe-8ce9-d2bfee5f69d1">The N-EVENT-REPORT service is used by a DIMSE Service User to report an event to a peer DIMSE Service User. It is a confirmed service.</para>
  <section label="10.1.1.1" status="4" xml:id="sect_10.1.1.1">
    <title>N-EVENT-REPORT Parameters</title>
  
  <para xml:id="para_dd51617d-a49d-4573-8e22-dc2e075ec463">
<xref linkend="table_10.1-1" xrefstyle="select: label"/> lists the parameters for this service.</para>
    <table frame="box" label="10.1-1" rules="all" xml:id="table_10.1-1">
    <caption>N-EVENT-REPORT Parameters</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_72215221-de0d-455e-9278-e558b98c2d5f">
          <emphasis role="bold">DIMSE Parameter Name</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_3237eb1d-d1ab-43d7-be4f-1f65381a0b5a">
          <emphasis role="bold">Req/Ind</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_542417ef-b613-47ee-ae72-6ce86fd9df90">
          <emphasis role="bold">Rsp/Conf</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0d893e53-86de-46bc-af59-f7c665bb3dca">Message ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_07df1143-6aba-4669-b3d9-70744416fa78">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_92384e83-b3d5-425b-8abb-2e460c219344">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_407abdfc-e145-426a-9999-d1c5b0aeaeb6">Message ID Being Responded To</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_408091ca-23a1-4d70-bee6-e654be347c87">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e1b963b6-3258-45d3-8fd3-b67f1042fc4a">M</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_bc0125a5-8022-4424-bf9e-d99176b8ca7b">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_538d16d6-e7bf-427d-b6b0-a0582ea83518">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1b14715b-c615-4fbd-afbc-5a77c0ec46aa">U(=)</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_29d75750-fdb9-4d2f-a079-09b44a7d0b70">Affected SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1393f240-d8bf-45ca-88b0-0bde5d55cfbe">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8867a36f-478b-47db-90ec-260183593668">U(=)</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1b50a7ae-def6-4ed0-9f6a-dfb534c06dfd">Event Type ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4071aaf7-ab2f-4d28-83b2-4050f1877e66">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9b0020f1-4549-495a-9e38-8299f49c1e3c">C(=)</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_31e6cf30-a938-4e53-a80a-2fe1f4a8587e">Event Information</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d335553a-2e69-4dc5-a4e3-d825ed316f88">U</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0a8e4eef-a765-46d9-bce1-246261badbfa">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_44b6fa18-ad47-46a6-9209-d392e78a4cf1">Event Reply</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_38baf012-fcb6-4a10-9a45-9f57e42154ea">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8f6f8f76-552c-401c-8bca-62d6a3b173ac">C</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_cc5f686a-90b0-43d5-833f-9ce398de3d73">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_eec0983c-f247-477c-8938-f8bd005fe28f">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a6120c7b-b877-4989-b75d-f0ce99c328b6">M</para>
      </td>
    </tr>
    </tbody>
  </table>
  <section label="10.1.1.1.1" status="5" xml:id="sect_10.1.1.1.1">
    <title>Message ID</title>
  
  <para xml:id="para_c0478012-fcd2-424b-9791-ea6fe0eba84f">This parameter identifies the operation. It is used to distinguish this operation from other notifications or operations that the DIMSE Service Provider may have in progress. No two identical values for the Message ID (0000,0110) shall be used for outstanding operations or notifications.</para>
  <note>
    <para xml:id="para_65b8ac07-478b-4749-af66-83e374344cc0">The Message ID (0000,0110) is recommended to be unique within the scope of an Association, to support debug procedures.</para>
  </note>
  </section>
<section label="10.1.1.1.2" status="5" xml:id="sect_10.1.1.1.2">
    <title>Message ID Being Responded To</title>
  
  <para xml:id="para_d9c50ed2-0b4b-449b-aa5c-fc65f19ee3c1">This parameter specifies the Message ID (0000,0110) of the notification request/indication to which this response/confirmation applies.</para>
  </section>
<section label="10.1.1.1.3" status="5" xml:id="sect_10.1.1.1.3">
    <title>Affected SOP Class UID</title>
  
  <para xml:id="para_369b98e3-16f7-42ee-ae2e-88941455d403">For the request/indication, this parameter specifies the SOP Class of the SOP Instance for the event. It may be included in the response/confirmation. If included in the response/confirmation, this parameter shall be equal to the value in the request/indication.</para>
  </section>
<section label="10.1.1.1.4" status="5" xml:id="sect_10.1.1.1.4">
    <title>Affected SOP Instance UID</title>
  
  <para xml:id="para_0cb8c539-01cd-49c1-a4b7-1360dadfdbf8">For the request/indication, this parameter specifies the SOP Instance for the event. It may be included in the response/confirmation. If included in the response/confirmation, this parameter shall be equal
  <emphasis role="bold">to the</emphasis>value in the request/indication.</para>
  </section>
<section label="10.1.1.1.5" status="5" xml:id="sect_10.1.1.1.5">
    <title>Event Type ID</title>
  
  <para xml:id="para_7527cfac-6c3a-4efc-b2b2-16ea517df6f3">This parameter specifies the type of event being reported. It may be included in the success response/confirmation and shall be included if the Event Reply parameter is included.</para>
  <note>
    <para xml:id="para_d4265da3-4047-4e66-befd-222a29ccbebb">Service Class Specifications contained in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/> defines any application usage of the Event Type ID parameter.</para>
  </note>
  </section>
<section label="10.1.1.1.6" status="5" xml:id="sect_10.1.1.1.6">
    <title>Event Information</title>
  
  <para xml:id="para_0a926edc-df67-4f1b-8d18-fa1c071150c2">This application-specific parameter contains information that the Invoking DIMSE Service User is able to supply about the event.</para>
  <note>
    <para xml:id="para_34d8944f-2fc9-473c-8f2a-e2f9690a8d2a">Service Class Specifications contained in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/> defines any application usage of the Event Information parameter.</para>
  </note>
  </section>
<section label="10.1.1.1.7" status="5" xml:id="sect_10.1.1.1.7">
    <title>Event Reply</title>
  
  <para xml:id="para_fecca05c-f125-4f52-9599-9bf41ef1390f">This application-specific parameter contains the optional reply to the event report. It may only be included in the success response/confirmation.</para>
  <note>
    <para xml:id="para_b5e1d6e1-c38b-4774-9a2b-4ab3126f4ef6">Service Class Specifications contained in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/> defines any application usage of the Event Reply parameter.</para>
  </note>
  </section>
<section label="10.1.1.1.8" status="5" xml:id="sect_10.1.1.1.8">
    <title>Status</title>
  <para xml:id="para_74783bdc-98ef-4a66-8e64-31a37df6b54c">This parameter contains the error or success notification for the operation. It shall be included by the Performing DIMSE Service User in any response/confirmation. The following types of status may occur (see also <xref linkend="chapter_C" xrefstyle="template:Annex %n"/>):</para>
<itemizedlist>
  <listitem>
<para xml:id="para_2a089c8b-456c-4283-9f86-00190a7e3a40">Class-Instance conflict (0119H) - This indicates that the specified SOP Instance is not a member of the specified SOP class.</para>
</listitem>
  <listitem>
<para xml:id="para_df0d2602-b28d-4a11-ba6a-5654f9fe54e0">Duplicate invocation (0210H) - This indicates that the Message ID (0000,0110) specified is allocated to another notification or operation.</para>
</listitem>
  <listitem>
<para xml:id="para_f59887e8-5a44-4c67-b1a5-15bc4218af95">Invalid argument value (0115H) - This indicates that the event information value specified was out of range or otherwise inappropriate.</para>
</listitem>
  <listitem>
<para xml:id="para_115fd909-aa9c-4792-81b7-2aba8f917c68">Invalid SOP Instance (0117H) - This indicates that the SOP Instance UID specified implied a violation of the UID construction rules.</para>
</listitem>
  <listitem>
<para xml:id="para_07b20026-aada-4ec3-ae52-c0c9d43bf33d">Mistyped argument (0212H) - This indicates that one of the parameters supplied has not been agreed for use on the Association between the DIMSE Service Users.</para>
</listitem>
  <listitem>
<para xml:id="para_87c94342-6343-4fcb-9603-e75c1e9cfe0b">No such argument (0114H) - This indicates that the event information specified was not recognized.</para>
</listitem>
  <listitem>
<para xml:id="para_a4121313-d338-49b8-a2b4-0fbfff56ab50">No such Event Type (0113H) - This indicates that the Event Type specified was not recognized.</para>
</listitem>
  <listitem>
<para xml:id="para_2832575e-a803-4da4-88c9-4905ae57e53e">No such SOP Class (0118H) - This indicates that the SOP Class was not recognized.</para>
</listitem>
  <listitem>
<para xml:id="para_f7cdf78c-f4a0-4297-acbe-35b4c9ce005b">No such SOP Instance (0112H) - This indicates that the SOP Instance was not recognized.</para>
</listitem>
  <listitem>
<para xml:id="para_6d42bb01-7272-49be-9b47-a6ae3061b34a">Processing Failure (0110H) - This indicates that a general failure in processing the operation was encountered.</para>
</listitem>
  <listitem>
<para xml:id="para_c32e3ada-bc20-4c26-b16a-145546e5f880">Resource limitation (0213H) - This indicates that the operation was not performed due to resource limitation.</para>
</listitem>
  <listitem>
<para xml:id="para_aa33f5b9-a799-4825-9b24-abc0cae92509">Success (0000H) - This indicates that successful notification.</para>
</listitem>
  <listitem>
<para xml:id="para_7126e6f1-17da-4047-b0ed-5066286ca3b9">Unrecognized operation (0211H) - This indicates that the operation is not one of those agreed between the DIMSE Service Users.</para>
</listitem>
</itemizedlist>
  </section>
</section>
<section label="10.1.1.2" status="4" xml:id="sect_10.1.1.2">
    <title>N-EVENT-REPORT Service Procedures</title>
  
  <para xml:id="para_d73219a0-c11b-40eb-a74a-df254c62bf22">The following N-EVENT-REPORT procedures apply:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_7659ccc7-324c-4528-b9f5-87a32d0bfe97">The Invoking DIMSE Service User reports an event to the Performing DIMSE Service User by issuing an N-EVENT-REPORT Request primitive to the DIMSE Service Provider.</para>
</listitem>
<listitem>
<para xml:id="para_0ad986d9-c250-4f7a-afe9-9142fa897e05">The DIMSE Service Provider issues an N-EVENT-REPORT indication primitive to the Performing DIMSE Service User.</para>
</listitem>
<listitem>
<para xml:id="para_801868fd-42d8-4cd7-be00-ffad96ce2486">The Performing DIMSE Service User reports acceptance or rejection of the N-EVENT-REPORT Request primitive by issuing an N-EVENT-REPORT response primitive to the DIMSE Service Provider.</para>
</listitem>
<listitem>
<para xml:id="para_32c058a3-14fa-41d8-a821-9948a3d06e36">The DIMSE Service Provider issues an N-EVENT-REPORT confirmation primitive to the Invoking DIMSE Service User, completing the N-EVENT-REPORT notification.</para>
</listitem>
</orderedlist>
  <para xml:id="para_47b5b821-1930-41d8-b672-4012c8ceffea">The Performing DIMSE Service User may return an N-EVENT-REPORT response primitive with the status of Failed or Refused before the entire N-EVENT-REPORT indication (Data Set) has been completely transmitted by the Invoking DIMSE Service User. A N-EVENT-REPORT response primitive with the status of Success or Warning shall not be returned until the entire N-EVENT-REPORT indication has been received by the Performing DIMSE Service User.</para>
  <note>
    <para xml:id="para_defaee64-7cdb-49d8-ad85-f91f2ed326a6">Such an occurrence of a "Failed" response is often called an early failed response.</para>
  </note>
  </section>
</section>
<section label="10.1.2" status="3" xml:id="sect_10.1.2">
    <title>N-GET Service</title>
  
  <para xml:id="para_3c96fc65-282d-48f9-b676-7fbe7eee5c31">The N-GET service is used by a DIMSE Service User to retrieve Attribute Values from a peer DIMSE Service User. It is a confirmed service.</para>
  <section label="10.1.2.1" status="4" xml:id="sect_10.1.2.1">
    <title>N-GET Parameters</title>
  
  <para xml:id="para_25fc56f9-ecf9-49b2-924e-af064495770a">
<xref linkend="table_10.1-2" xrefstyle="select: label"/> lists the parameters for this service.</para>
    <table frame="box" label="10.1-2" rules="all" xml:id="table_10.1-2">
    <caption>N-GET Parameters</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_84b21a8b-8080-435e-a7e5-5a77516f1f69">
          <emphasis role="bold">DIMSE Parameter Name</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_8d05dbdc-818c-44b9-b8da-f715ae8fbb17">
          <emphasis role="bold">Req/Ind</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_8b27eead-7df1-41a4-8a61-ede76b5bc002">
          <emphasis role="bold">Rsp/Conf</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5a24535b-d901-4171-8ee6-edd7389c42f9">Message ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_65234215-9497-4216-a057-0d7f181cce15">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e5711abe-4004-4df3-bb66-16761477e7cd">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_409d49cd-dd4d-43c0-a6be-053d1cdf6e9e">Message ID Being Responded To</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b45e4ec1-7e14-4f9b-8230-7b79fcf9ebef">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c336a5c2-1847-4817-a255-a90839fa59e6">M</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e01d723b-3312-4484-a2ac-d498fe640ca5">Requested SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0ba52379-b2b9-4b3c-8f51-827ab3bbf8a5">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_571e0897-f203-4b86-b145-c514e161d45c">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_34d8f775-0ca5-42cd-98be-50fd57a8535d">Requested SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d058f98f-093c-4c66-984d-06373c78dba1">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a56ff596-6214-4e87-9737-7f717f44d30e">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_2e54d49c-c871-42f7-bf54-9bf1c8ba32d5">Attribute Identifier List</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7f0ecf94-bc72-44f0-bd80-606514ac2582">U</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6adbfa0d-ce7b-47de-9e94-882b1e580f88">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b4a7f13d-180b-4560-9cde-0f944ee33abc">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ccee23f6-584f-4242-ba00-30cdf59e5603">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0f708d75-38a5-4be4-af9a-509b768bd2c5">U</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_352b9e9c-84e0-4f38-a2c7-a3770378351f">Affected SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_87a677c4-ddb1-474b-8ee0-d1cf402f2b70">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2a826882-a2de-4b0d-b8f7-09b27c0b0126">U</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_34d68df5-220a-4098-a104-0d7e9f3183a2">Attribute List</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_cc6a0a59-f119-4ca1-82ce-f02b52cb998d">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_72beb95f-5963-43f7-b41f-f2277bc54fa4">C</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c0346880-acf5-47d7-8db7-8b9551cf9f6b">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4934f6b4-33bd-428b-a3c6-3e85c7118604">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_15523844-524d-46ec-a572-469b925b68c0">M</para>
      </td>
    </tr>
    </tbody>
  </table>
  <section label="10.1.2.1.1" status="5" xml:id="sect_10.1.2.1.1">
    <title>Message ID</title>
  
  <para xml:id="para_4e4c4a55-e81c-407f-812f-ce61de14fda6">This parameter identifies the operation. It is used to distinguish this operation from other notifications or operations that the DIMSE Service Provider may have in progress. No two identical values for the Message ID (0000,0110) shall be used for outstanding operations or notifications.</para>
  <note>
    <para xml:id="para_5eee1420-75c7-40f5-90d2-8ddba18778ec">The Message ID (0000,0110) is recommended to be unique within the scope of an Association, to support debug procedures.</para>
  </note>
  </section>
<section label="10.1.2.1.2" status="5" xml:id="sect_10.1.2.1.2">
    <title>Message ID Being Responded To</title>
  
  <para xml:id="para_49e71530-e9ac-4e5f-bd53-2b4ce99b8955">This parameter specifies the Message ID (0000,0110) of the operation request/indication to which this response/confirmation applies.</para>
  </section>
<section label="10.1.2.1.3" status="5" xml:id="sect_10.1.2.1.3">
    <title>Requested SOP Class UID</title>
  
  <para xml:id="para_0d4b0efe-e0ba-4843-999f-5df23a7d1a6a">This parameter specifies the SOP Class for which Attribute Values are to be retrieved.</para>
  </section>
<section label="10.1.2.1.4" status="5" xml:id="sect_10.1.2.1.4">
    <title>Requested SOP Instance UID</title>
  
  <para xml:id="para_80b043b3-c597-4af1-bfe5-4fb45f4d73d0">This parameter specifies the SOP Instance for which Attribute Values are to be retrieved.</para>
  </section>
<section label="10.1.2.1.5" status="5" xml:id="sect_10.1.2.1.5">
    <title>Attribute Identifier List</title>
  
  <para xml:id="para_cd77d80e-7f04-419c-b570-a33f6de1169d">This parameter contains a set of Attribute identifiers for which the Attribute Values are to be returned by the Performing DIMSE Service User. If this parameter is omitted, all Attribute identifiers are assumed. The definitions of the Attributes are found in the specification of the Information Object Definition in <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>.</para>
  </section>
<section label="10.1.2.1.6" status="5" xml:id="sect_10.1.2.1.6">
    <title>Affected SOP Class UID</title>
  
  <para xml:id="para_e022199c-4710-42bc-8355-058300c86cc5">This parameter may be included in the response/confirmation. If included in the response/confirmation, this parameter shall be equal to the Requested SOP Class UID parameter value used in the request/indication.</para>
  </section>
<section label="10.1.2.1.7" status="5" xml:id="sect_10.1.2.1.7">
    <title>Affected SOP Instance UID</title>
  
  <para xml:id="para_d31eabfc-f90e-4232-aeac-da720e1a15e7">This parameter specifies the SOP Instance for which Attribute Values are returned. It may be included in any response/confirmation and when included shall be equal to the Requested SOP Instance UID (0000,1001) parameter value used in the invocation.</para>
  </section>
<section label="10.1.2.1.8" status="5" xml:id="sect_10.1.2.1.8">
    <title>Attribute List</title>
  
  <para xml:id="para_cf6b42ec-be8a-457a-b888-be9ea36c9ced">This parameter contains the set of Attribute identifiers and values that are returned by the Performing DIMSE Service User. It shall be included in the success response/confirmation.</para>
  </section>
<section label="10.1.2.1.9" status="5" xml:id="sect_10.1.2.1.9">
    <title>Status</title>
  
  <para xml:id="para_0d753bbb-9e15-4e72-8ddb-d8a6ca195807">This parameter contains the error or success notification for the operation. It shall be included by the Performing DIMSE Service User in any response/confirmation. The following types of status may occur (see also <xref linkend="chapter_C" xrefstyle="template:Annex %n"/>):</para>
<itemizedlist>
  <listitem>
<para xml:id="para_45dfd1c5-2ad6-4247-b826-40e5c68c4326">Attribute List warning (0107H) - This indicates that one or more Attribute Values were not read because the specified Attribute was not recognized. The Attribute Values that could be read are returned.</para>
</listitem>
  <listitem>
<para xml:id="para_dd119344-f551-42d2-a916-68eb919d7073">Class-Instance conflict (0119H) - This indicates that the specified SOP Instance is not a member of the specified SOP Class.</para>
</listitem>
  <listitem>
<para xml:id="para_bbf7d00d-ac88-45e8-9210-941f21c45345">Duplicate invocation (0210H) - This indicates that the Message ID (0000,0110) specified is allocated to another notification or operation.</para>
</listitem>
  <listitem>
<para xml:id="para_5387994d-ab5c-4aa8-a606-104bc38cae37">Invalid SOP Instance (0117H) - This indicates that the SOP Instance UID specified implied a violation of the UID construction rules.</para>
</listitem>
  <listitem>
<para xml:id="para_eecc7b07-aa17-4dc0-b55a-abf02b9c8783">Mistyped argument (0212H) - This indicates that one of the parameters supplied has not been agreed for use on the Association between the DIMSE Service Users.</para>
</listitem>
  <listitem>
<para xml:id="para_68eabf53-8ca0-41fc-952e-cd059e272694">No such SOP Class (0118H) - This indicates that the SOP Class was not recognized.</para>
</listitem>
  <listitem>
<para xml:id="para_d7e4fcf1-fa28-4d52-b6ba-beb13481d385">No such SOP Instance (0112H) - This indicates that the SOP Instance was not recognized.</para>
</listitem>
  <listitem>
<para xml:id="para_5e4c546a-5394-4a81-9b35-f3e7b37dbdf7">Processing Failure (0110H) - This indicates that a general failure in processing the operation was encountered.</para>
</listitem>
  <listitem>
<para xml:id="para_af60831d-070f-44a8-bfe2-0cefdcbe25c5">Resource limitation (0213H) - This indicates that the operation was not performed due to resource limitation.</para>
</listitem>
  <listitem>
<para xml:id="para_a26ba732-aae9-4ed4-ba22-cfb920a35973">Success (0000H) - This indicates a successful operation.</para>
</listitem>
  <listitem>
<para xml:id="para_8b5fc79d-4e83-4f04-b0ea-ea5af72a7be2">Unrecognized operation (0211H) - This indicates that the operation is not one of those agreed between the DIMSE Service Users.</para>
</listitem>
  <listitem>
<para xml:id="para_1ab7d7ce-a777-4341-9c69-396146626e6d">Refused: Not authorized (0124H) - This indicates that the peer DIMSE Service User was not authorized to invoke the operation.</para>
</listitem>
  <listitem>
      <para xml:id="para_ffb2da4b-bb72-4599-955b-4e0f65ef39c2">Warning (Status value is Service Class specific) - This indicates that not all optional Attributes were returned by the Performing DIMSE Service User.</para>
</listitem>
  <listitem>
      <para xml:id="para_f7f37687-f5ed-4700-8266-e0a92654c8b5">Failed (Status value is Service Class specific) - This indicates that the Performing DIMSE Service User failed to complete the operation.</para>
</listitem>
</itemizedlist>
</section>
</section>
<section label="10.1.2.2" status="4" xml:id="sect_10.1.2.2">
    <title>N-GET Service Procedures</title>
  
  <para xml:id="para_a091d64e-c186-4065-b7ca-834ee18aba2e">The following N-GET procedures apply;</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_b69bad1e-1f90-40b5-a134-e4ab4bf915a0">The Invoking DIMSE Service User requests the Performing DIMSE Service User to retrieve Attribute Value(s) by issuing an N-GET Request primitive to the DIMSE Service Provider.</para>
</listitem>
<listitem>
<para xml:id="para_e4499a22-a2cd-456a-93e6-a652994980f5">The DIMSE Service Provider issues an N-GET indication primitive to the Performing DIMSE Service User.</para>
</listitem>
<listitem>
<para xml:id="para_ea1488fd-622b-4f90-97de-4c09b93aa53d">If the operation can be performed, then the Performing DIMSE Service User retrieves the requested Attribute Value(s) and generates a response indicating acceptance of the N-GET Request primitive by issuing an N-GET response primitive to the DIMSE Service Provider. In this case the following procedure does not apply.</para>
</listitem>
<listitem>
<para xml:id="para_79d81fcb-1f3d-405c-a67e-d40e34bed585">If the operation cannot be performed, then the Performing DIMSE Service User rejects the N-GET request by issuing an N-GET response primitive with the appropriate error code to the DIMSE Service Provider.</para>
</listitem>
<listitem>
<para xml:id="para_da755fdc-a993-4776-b2a0-94e2882f7f25">The DIMSE Service Provider issues an N-GET confirmation primitive to the Invoking DIMSE Service User, completing the N-GET operation.</para>
</listitem>
</orderedlist>
  </section>
</section>
<section label="10.1.3" status="3" xml:id="sect_10.1.3">
    <title>N-SET Service</title>
  
  <para xml:id="para_c45be476-3e91-4488-893e-fde25fd191b1">The N-SET service is used by a DIMSE Service User to request the modification of Attribute Values from a peer DIMSE Service User. It is a confirmed service.</para>
  <section label="10.1.3.1" status="4" xml:id="sect_10.1.3.1">
    <title>N-SET Parameters</title>
  
  <para xml:id="para_38a130c1-ae00-444a-9e71-66ced966e6ee">
<xref linkend="table_10.1-3" xrefstyle="select: label"/> lists the parameters for this service.</para>
    <table frame="box" label="10.1-3" rules="all" xml:id="table_10.1-3">
    <caption>N-SET Parameters</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_30b188fd-8203-4954-9720-0845b2f77093">
          <emphasis role="bold">DIMSE Parameter Name</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_ebe697db-d60f-4752-b2c4-90013a63fe07">
          <emphasis role="bold">Req/Ind</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_3fdf7ea3-de20-4752-a865-a398d7cdf406">
          <emphasis role="bold">Rsp/Conf</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_173ccf22-eedb-4924-bf66-a0225df13a0b">Message ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6e7d1235-dd6c-43b9-8868-98b983a652c8">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4eebb42e-6e1e-477a-987d-778caaed6400">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_aeed5bc4-e4ea-4e41-90da-7751b1956f5f">Message ID Being Responded To</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2a6dc30b-4275-40ca-a2a7-1ec50f9c7c1b">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_13ae3e61-b6f5-406f-a6aa-c9487b3d6140">M</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_dcd51a73-134e-4d1e-88ff-a3e63f075b42">Requested SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_75fbe727-f420-4b6a-98dc-bf9d4063ab1f">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b9e8b0b9-0459-487a-aeb4-ff13b236d6c6">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_61c06a6b-f6a3-49d1-b813-1e249fbfbbc0">Requested SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_3b958665-d8f8-400e-948b-60dd4c0f72ef">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c9f1ef69-b8bd-4f72-b9a8-dd414cb63c97">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b0106772-b016-491e-9dba-e12e25348631">Modification List</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e62b2235-c683-48ac-9118-f7d6400279b1">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c3dd789c-a3a9-4824-9794-0649deffcd89">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9e218d52-e48a-4337-b87b-c1c588fcc250">Attribute List</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_782f2fab-b551-47d8-ae3d-2adc8c00c7dd">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_eee1835c-007f-487d-928f-ed4b3964070d">U</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d254cf47-96b6-45d8-a341-b0922fc1ea2a">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a82467f1-fb55-4b02-bbcf-f35b9a7d69df">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0bff1321-2f6c-4134-9a39-3a14f59d58d9">U</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e14cb66d-c522-4e79-a746-68a8395c90ca">Affected SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_cd1ae15d-56f1-4e16-9d47-34439fd532f9">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0032a0b6-d3d0-4944-99b1-1f11ea9d4240">U</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9178acdc-172c-4c54-9055-54124335ddd7">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b3f79fff-4046-444c-ba77-86bd599ea755">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6963f926-77e3-44e8-844b-33af71fc68a2">M</para>
      </td>
    </tr>
    </tbody>
  </table>
  <section label="10.1.3.1.1" status="5" xml:id="sect_10.1.3.1.1">
    <title>Message ID</title>
  
  <para xml:id="para_43ff158d-a1bf-4cf4-a7d7-a68277e97b28">This parameter identifies the operation. It is used to distinguish this operation from other notifications or operations that the DIMSE Service Provider may have in progress. No two identical values for the Message ID (0000,0110) shall be used for outstanding operations or notifications.</para>
  <note>
    <para xml:id="para_f881eb90-5214-4b99-b8ea-3bbe036a7512">The Message ID (0000,0110) is recommended to be unique within the scope of an Association, to support debug procedures.</para>
  </note>
  </section>
<section label="10.1.3.1.2" status="5" xml:id="sect_10.1.3.1.2">
    <title>Message ID Being Responded To</title>
  
  <para xml:id="para_e97552f3-c6ac-4c21-98ff-fa36dbf94460">This parameter specifies the Message ID (0000,0110) of the operation request/indication to which this response/confirmation applies.</para>
  </section>
<section label="10.1.3.1.3" status="5" xml:id="sect_10.1.3.1.3">
    <title>Requested SOP Class UID</title>
  
  <para xml:id="para_e581d14e-2be0-4d73-9b74-bc1daf0237d3">This parameter specifies the SOP Class for which Attribute Values are to be modified.</para>
  </section>
<section label="10.1.3.1.4" status="5" xml:id="sect_10.1.3.1.4">
    <title>Requested SOP Instance UID</title>
  
  <para xml:id="para_fc325163-3c1b-44cb-9fd6-cd172458eadf">This parameter specifies the SOP Instance for which Attribute Values are to be modified.</para>
  </section>
<section label="10.1.3.1.5" status="5" xml:id="sect_10.1.3.1.5">
    <title>Modification List</title>
  
  <para xml:id="para_609328cf-2e29-4dc0-aac8-42f14c9a819a">This parameter contains the set of Attribute identifiers and values that are to be used by the Performing DIMSE Service User to replace the current values of the Attributes specified.</para>
  </section>
<section label="10.1.3.1.6" status="5" xml:id="sect_10.1.3.1.6">
    <title>Attribute List</title>
  
  <para xml:id="para_991045f3-96bc-4d58-9ee6-ddb303ebdc13">This parameter contains the set of Attribute identifiers and values that were used by the Performing DIMSE Service User to replace the values of the Attributes specified. It may be included in the success response/confirmation.</para>
  </section>
<section label="10.1.3.1.7" status="5" xml:id="sect_10.1.3.1.7">
    <title>Affected SOP Class UID</title>
  
  <para xml:id="para_df3a8aa4-fd46-45b4-8c30-62dd1896ea38">This parameter may be included in the response/confirmation. If included in the response/confirmation, this parameter shall be equal to the Requested SOP Class UID parameter value used in the request/indication.</para>
  </section>
<section label="10.1.3.1.8" status="5" xml:id="sect_10.1.3.1.8">
    <title>Affected SOP Instance UID</title>
  
  <para xml:id="para_b69cefef-4398-4a6e-93ff-86e5d26e5f19">This parameter specifies the SOP Instance for which Attribute Values were modified. It may be included in any response/confirmation and when included shall be equal to the Requested SOP Instance UID (0000,1001) parameter value used in the invocation.</para>
  </section>
<section label="10.1.3.1.9" status="5" xml:id="sect_10.1.3.1.9">
    <title>Status</title>
  
  <para xml:id="para_9c1720f0-5caa-4a3e-a479-0add7462b9b9">This parameter contains the error or success notification for the operation. It shall be included by the Performing DIMSE Service User in any response/confirmation. The following types of status may occur (see also <xref linkend="chapter_C" xrefstyle="template:Annex %n"/>):</para>
<itemizedlist>
  <listitem>
<para xml:id="para_14650a81-a258-4635-a10a-f62fc31d4efc">Class-Instance conflict (0119H) - This indicates that the specified SOP Instance is not a member of the specified SOP Class.</para>
</listitem>
  <listitem>
<para xml:id="para_743e5948-4eb2-449b-9786-88b3a8444580">Duplicate invocation (0210H) - This indicates that the Message ID (0000,0110) specified is allocated to another notification or operation.</para>
</listitem>
  <listitem>
<para xml:id="para_c9950a0a-5896-4225-8237-cf173834163c">Invalid Attribute Value (0106H) - This indicates that the Attribute Value specified was out of range or otherwise inappropriate.</para>
</listitem>
  <listitem>
<para xml:id="para_88804362-6630-4641-9948-752af79c0202">Attribute Value out of range (0116H) - This indicates that the Attribute Value specified was out of range or otherwise inappropriate. The Attribute Values that could be modified were modified.</para>
</listitem>
  <listitem>
<para xml:id="para_353e60fc-c1e1-4f57-9aeb-6336a9f4b4fd">Mistyped argument (0212H) - This indicates that one of the parameters supplied has not been agreed for use on the Association between the DIMSE Service Users.</para>
</listitem>
  <listitem>
<para xml:id="para_54108f35-2a51-45a7-b652-20410b7c19a6">Invalid SOP Instance (0117H) - This indicates that the SOP Instance UID specified implied a violation of the UID construction rules.</para>
</listitem>
  <listitem>
<para xml:id="para_8cf32770-204d-4f4c-a7bf-14e33324223b">Missing Attribute Value (0121H) - This indicates that a required Attribute Value was not supplied.</para>
</listitem>
  <listitem>
<para xml:id="para_2f468e80-65f3-46c9-a0c6-476b313597f1">No such Attribute (0105H) - This indicates that the Tag for the specified Attribute was not recognized.</para>
</listitem>
  <listitem>
<para xml:id="para_62ebb814-3b53-4ce4-b6dc-8c839c21465f">Attribute List warning (0107H) - This indicates that one or more Attribute Values were not modified because the specified Attributes were not recognized. The Attribute Values that could be modified were modified.</para>
</listitem>
  <listitem>
<para xml:id="para_8fe69bf5-5f8f-4f75-8079-f8f621225735">No such SOP Class (0118H) - This indicates that the SOP Class was not recognized.</para>
</listitem>
  <listitem>
<para xml:id="para_9eb61f30-7a32-4ff9-9e51-f122181575c2">No such SOP Instance (0112H) - This indicates that the SOP Instance was not recognized.</para>
</listitem>
  <listitem>
<para xml:id="para_dadf18c4-e7c9-471b-8d49-a2b0d77c530d">Processing Failure (0110H) - This indicates that a general failure in processing the operation was encountered.</para>
</listitem>
  <listitem>
<para xml:id="para_a4372fbd-d880-48bc-b6c8-4494aebbdcaf">Resource limitation (0213H) - This indicates that the operation was not performed due to resource limitation.</para>
</listitem>
  <listitem>
<para xml:id="para_b6023420-18b6-48a9-8bef-d622216f3b86">Success (0000H) - This indicates a successful operation.</para>
</listitem>
  <listitem>
<para xml:id="para_afb11504-5158-4095-8fd2-1a6356755656">Unrecognized operation (0211H) - This indicates that the operation is not one of those agreed between the DIMSE Service Users.</para>
</listitem>
  <listitem>
<para xml:id="para_a0a5543f-19e5-47b4-8afe-8d07f994ceef">Refused: Not authorized (0124H) - This indicates that the peer DIMSE Service User was not authorized to invoke the operation.</para>
</listitem>
  <listitem>
    <para xml:id="para_2b9cfe2f-677f-400b-a036-1db67c4a83b2">Failed (Status value is Service Class specific) - This indicates that the operation was not performed as certain conditions for operation were not met.</para>
  </listitem>
  <listitem>
    <para xml:id="para_83e480ff-9e60-4fee-a4a7-ffe8b9845e00">Warning (Status value is Service Class specific) - This indicates that the operation was performed partially or with modified conditions.</para>
  </listitem>
</itemizedlist>
</section>
</section>
<section label="10.1.3.2" status="4" xml:id="sect_10.1.3.2">
    <title>N-SET Service Procedures</title>
  
  <para xml:id="para_bce4a269-f883-46d4-b5ac-82f4be90ebab">The following N-SET procedures apply:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_42a5a6f6-e1e1-4bca-8f56-96ce585d3280">The Invoking DIMSE Service User requests the Performing DIMSE Service User to modify Attribute Value(s) by issuing an N-SET Request primitive to the DIMSE Service Provider.</para>
</listitem>
<listitem>
<para xml:id="para_e5d144e3-74bd-4afc-be78-1ce4d1a36c03">The DIMSE-service provider issues an N-SET indication primitive to the Performing DIMSE Service User.</para>
</listitem>
<listitem>
<para xml:id="para_44d6b0c8-dcde-4b04-81fe-0f1d07cf959c">If the operation can be performed, then the Performing DIMSE Service User modifies the requested Attribute Value(s) and generates a response indicating acceptance of the N-SET Request primitive by issuing an N-SET response primitive to the DIMSE Service Provider. In this case the following procedure does not apply.</para>
</listitem>
<listitem>
<para xml:id="para_15a33d64-2ce6-4a3b-b4b0-48b1b3fb0ed4">If the operation cannot be performed, then the Performing DIMSE Service User rejects the N-SET request by issuing an N-SET response primitive with the appropriate error code to the DIMSE Service Provider.</para>
</listitem>
<listitem>
<para xml:id="para_d599ef42-3656-4eca-9d7c-38819dcc0343">The DIMSE Service Provider issues an N-SET confirmation primitive to the Invoking DIMSE Service User, completing the N-SET operation.</para>
</listitem>
</orderedlist>
  <para xml:id="para_7bcb33f6-942c-4b0f-b9ce-1f79f221f809">The Performing DIMSE Service User may return an N-SET response primitive with the status of Failed or Refused before the entire N-SET indication (Data Set) has been completely transmitted by the Invoking DIMSE Service User. A N-SET response primitive with the status of Success or Warning shall not be returned until the entire N-SET indication has been received by the Performing DIMSE Service User.</para>
  <note>
    <para xml:id="para_44891dad-efb7-4b55-a96c-b7dfc0e58fad">Such an occurrence of a "Failed" response is often called an early failed response.</para>
  </note>
  </section>
</section>
<section label="10.1.4" status="3" xml:id="sect_10.1.4">
    <title>N-ACTION Service</title>
  
  <para xml:id="para_565f7b63-cb66-4fa5-8217-573916676ea6">The N-ACTION service is used by a DIMSE Service User to request an action by a peer DIMSE Service User. It is a confirmed service.</para>
  <section label="10.1.4.1" status="4" xml:id="sect_10.1.4.1">
    <title>N-ACTION Parameters</title>
  
  <para xml:id="para_bac3adb7-90fb-428b-9935-98acf05e9628">
<xref linkend="table_10.1-4" xrefstyle="select: label"/> lists the parameters for this service.</para>
    <table frame="box" label="10.1-4" rules="all" xml:id="table_10.1-4">
    <caption>N-ACTION Parameters</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_6cedf7b9-41ec-4030-85bf-9e444dd1f0c1">
          <emphasis role="bold">DIMSE Parameter Name</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_76d5545c-27b8-4fe2-b74a-95b863baf18b">
          <emphasis role="bold">Req/Ind</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_80735f66-274a-46b6-9be5-e8ab441f9290">
          <emphasis role="bold">Rsp/Conf</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9d8d01b1-87d2-4484-a051-f54e64cee3b4">Message ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_94eac5d6-1e9a-4ff6-9409-26e8983dce83">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_434449f3-c770-4765-9e0e-8c34dad7f481">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b48c7d04-3bc9-4973-9286-d6ef986bfe83">Message ID Being Responded To</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5091951d-da99-47ee-8bda-1da4f5a1a80f">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6a9438d0-0e0e-46b1-800f-3bd3b6c965e6">M</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d222b4c0-658c-4ad1-b7da-a30d7fcaea1c">Requested SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_62560664-b5cd-49d7-8465-212b99ecc10e">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7c26b3bf-acbe-48a8-9f69-6a71e3aecca8">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_4b2882a2-34c0-40bd-b997-3036188f3e93">Requested SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_34a78051-accb-40cc-a317-e3de81539944">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c17902c0-7538-411c-8692-913638d0c771">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_7fdca1ab-601d-458c-8648-80530e5c1564">Action Type ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_264766c4-b6ca-4b96-8329-4069d00c3b1f">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_3eda74b5-7806-474e-8c01-96d22c6086dc">C(=)</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3c924261-0c29-470e-8c7f-3e50f9ff245a">Action Information</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_926ef40e-829e-4017-964e-17874cf2bd72">U</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b2feaa4a-7906-4f89-9398-62dfa016ab1f">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_cba5e7d2-d729-44e8-9fad-a1317206b59b">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2ee578a4-e76f-48c5-90f3-e245094c8f78">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_00002c45-d8de-49b0-9e0f-ac6c33e8313d">U</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_bfe4888e-1d54-4cf7-a47a-e6f23ce1fcd7">Affected SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5776d4d6-67b2-4b72-8421-14db66e2b427">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_43104983-b502-4a3a-8adf-e72cc457cfba">U</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c6cce66c-a741-41cc-94cb-da77bf608a64">Action Reply</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_353a6552-9a2b-4cae-815a-046418756522">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_fe9aebe9-3c0f-4978-9aaf-e299000c7051">C</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_491b173a-14a9-40de-a03b-df1b1d677108">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_416b185e-5e42-4c87-82cd-9e4969d5a273">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_95524d32-575a-48dc-8a3a-74fb291cfd7c">M</para>
      </td>
    </tr>
    </tbody>
  </table>
  <section label="10.1.4.1.1" status="5" xml:id="sect_10.1.4.1.1">
    <title>Message ID</title>
  
  <para xml:id="para_b323269d-b72d-4e4e-bf79-89e83e96f4e6">This parameter identifies the operation. It is used to distinguish this operation from other notifications or operations that the DIMSE Service Provider may have in progress. No two identical values for the Message ID (0000,0110) shall be used for outstanding operations or notifications.</para>
  <note>
    <para xml:id="para_3d0c5ec5-4007-4d46-ac1a-3e03d3508e71">The Message ID (0000,0110) is recommended to be unique within the scope of an Association, to support debug procedures.</para>
  </note>
  </section>
<section label="10.1.4.1.2" status="5" xml:id="sect_10.1.4.1.2">
    <title>Message ID Being Responded To</title>
  
  <para xml:id="para_8daf61b5-573f-44b9-9342-93e9edc1c29d">This parameter specifies the Message ID (0000,0110) of the operation request/indication to which this response/confirmation applies.</para>
  </section>
<section label="10.1.4.1.3" status="5" xml:id="sect_10.1.4.1.3">
    <title>Requested SOP Class UID</title>
  
  <para xml:id="para_8f9d398a-f271-49b2-b08a-343ddb08efdf">This parameter specifies the SOP Class for which the action is to be performed.</para>
  </section>
<section label="10.1.4.1.4" status="5" xml:id="sect_10.1.4.1.4">
    <title>Requested SOP Instance UID</title>
  
  <para xml:id="para_fc8a19b7-6955-44b1-b78b-91f4586984dd">This parameter specifies the SOP Instance on which the action is to be performed.</para>
  </section>
<section label="10.1.4.1.5" status="5" xml:id="sect_10.1.4.1.5">
    <title>Action Type ID</title>
  
  <para xml:id="para_6165af41-c343-4500-bfa4-c5726a15ea94">This parameter specifies a particular action that is to be performed. It may be included in the success response/confirmation and shall be included if the action reply parameter is included.</para>
  <note>
    <para xml:id="para_79dc4900-522c-42ae-bf41-d3a7c0c45fb2">Service Class Specifications contained in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/> defines any application usage of the Action Type ID (0000,1008) parameter.</para>
  </note>
  </section>
<section label="10.1.4.1.6" status="5" xml:id="sect_10.1.4.1.6">
    <title>Action Information</title>
  
  <para xml:id="para_c4e017d1-0c08-4302-b06e-61c32dfa3e7f">This parameter specifies extra application-specific information when necessary to further define the nature, variations, or operands of the action to be performed. The syntax and semantics of the parameter depend upon the action requested. It may only be included in the request/indication.</para>
  <note>
    <para xml:id="para_46f5e70b-235c-466b-a42b-9f03a0e1c026">Service Class Specifications contained in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/> defines any application usage of the Action Information parameter.</para>
  </note>
  </section>
<section label="10.1.4.1.7" status="5" xml:id="sect_10.1.4.1.7">
    <title>Affected SOP Class UID</title>
  
  <para xml:id="para_14bd4e6d-d144-4140-b9d7-7922c2a1f73a">This parameter may be included in the response/confirmation. If included in the response/confirmation, this parameter shall be equal to the Requested SOP Class UID parameter value used in the request/indication.</para>
  </section>
<section label="10.1.4.1.8" status="5" xml:id="sect_10.1.4.1.8">
    <title>Affected SOP Instance UID</title>
  
  <para xml:id="para_8b25c11a-d1e8-4a85-b93f-85546a22331f">This parameter specifies the SOP Instance on which the action is to be performed. It may be included in any response/confirmation and when included shall be equal to the Requested SOP Instance UID (0000,1001) parameter value used in the invocation.</para>
  </section>
<section label="10.1.4.1.9" status="5" xml:id="sect_10.1.4.1.9">
    <title>Action Reply</title>
  
  <para xml:id="para_eea1f95c-c2c9-445b-9230-014063f4b8d6">This parameter contains the application-specific reply to the action. It may be included in the success response/confirmation.</para>
  <note>
    <para xml:id="para_ade4351a-31f8-4678-bdc4-37a8daab320d">Service Class Specifications contained in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/> defines any application usage of the Action Reply parameter.</para>
  </note>
  </section>
<section label="10.1.4.1.10" status="5" xml:id="sect_10.1.4.1.10">
    <title>Status</title>
  
  <para xml:id="para_a03f6014-8875-46b2-a1cc-9fa84fa773ff">This parameter contains the error or success notification for the operation. It shall be included by the Performing DIMSE Service User in any response/confirmation. The following type of status may occur (see also <xref linkend="chapter_C" xrefstyle="template:Annex %n"/>):</para>
<itemizedlist>
  <listitem>
<para xml:id="para_f7ed75e0-39e5-48b5-9157-bc326b9c0b92">Class-Instance conflict (0119H) - This indicates that the specified SOP Instance is not a member of the specified SOP Class.</para>
</listitem>
  <listitem>
<para xml:id="para_4576723e-5649-4bee-9209-139beb0f2b8d">Duplicate invocation (0210H) - This indicates that the Message ID (0000,0110) specified is allocated to another notification or operation.</para>
</listitem>
  <listitem>
<para xml:id="para_9ca89caa-47e2-4580-ba77-6a1e9f68cfa9">Invalid argument value (0115H) - This indicates that the action information value specified was out of range or otherwise inappropriate.</para>
</listitem>
  <listitem>
<para xml:id="para_94ca31d0-79f6-44a6-89cf-bf8114d98a7a">Invalid SOP Instance (0117H) - This indicates that the SOP Instance UID specified implied a violation of the UID construction rules.</para>
</listitem>
  <listitem>
<para xml:id="para_bcee84f8-a022-4a15-a6e5-0fc497810276">Mistyped argument (0212H) - This indicates that one of the parameters supplied has not been agreed for use on the Association between the DIMSE Service Users.</para>
</listitem>
  <listitem>
<para xml:id="para_05cc88cc-e4df-47d0-8148-28866062a334">No such Action (0123H) - This indicates that the Action Type specified was not supported.</para>
</listitem>
  <listitem>
<para xml:id="para_7a2a544e-eb1f-454d-85e8-9ffbadf648e3">No such argument (0114H) - This indicates that the action information specified was not supported.</para>
</listitem>
  <listitem>
<para xml:id="para_50c4307b-b743-42b3-a726-506cc435de7a">No such SOP Class (0118H) - This indicates that the SOP Class was not recognized.</para>
</listitem>
  <listitem>
<para xml:id="para_42fd5646-20e6-466c-a886-44d6f6df87b5">No such SOP Instance (0112H) - This indicates that the SOP Instance was not recognized.</para>
</listitem>
  <listitem>
<para xml:id="para_a25015fa-ef5f-4236-9075-5596df935b83">Processing Failure (0110H) - This indicates that a general failure in processing the operation was encountered.</para>
</listitem>
  <listitem>
<para xml:id="para_17023b88-a5b2-4b01-8c25-450ad3631bd3">Resource limitation (0213H) - This indicates that the operation was not performed due to resource limitation.</para>
</listitem>
  <listitem>
<para xml:id="para_77175464-c2fe-4872-9f0a-e8d2601a6580">Success (0000H) - This indicates a successful operation.</para>
</listitem>
  <listitem>
<para xml:id="para_5e84ff0d-6ab4-4ed4-afb9-ab1b49e73988">Unrecognized operation (0211H) - This indicates that the operation is not one of those agreed between the DIMSE Service Users.</para>
</listitem>
  <listitem>
<para xml:id="para_357cefe1-f5d7-48d1-af5e-2703d2930529">Refused: Not authorized (0124H) - This indicates that the peer DIMSE Service User was not authorized to invoke the operation.</para>
</listitem>
  <listitem>
      <para xml:id="para_2f079914-3e42-4676-964b-4adb9f4eb204">Failed (Status value is Service Class specific) - This indicates that the operation was not performed as certain conditions for operation were not met.</para>
  </listitem>
  <listitem>
      <para xml:id="para_7100ec47-bb3f-4368-9fd8-97f1a5320407">Warning (Status value is Service Class specific) - This indicates that the operation was performed partially or with modified conditions.</para>
  </listitem>
  </itemizedlist>
</section>
</section>
<section label="10.1.4.2" status="4" xml:id="sect_10.1.4.2">
    <title>N-ACTION Service Procedures</title>
  
  <para xml:id="para_c9c9c515-bce3-41e0-8b58-ef729c5ce15b">The following N-ACTION procedures apply:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_0910f97d-3734-4fb6-a836-c1d432005f7d">The Invoking DIMSE Service User requests the Performing DIMSE Service User to perform an action on a managed SOP Instance by issuing an N-ACTION Request primitive to the DIMSE Service Provider.</para>
</listitem>
<listitem>
<para xml:id="para_70bc3611-de5b-4cb9-b330-4dcb526fa710">The DIMSE-service provider issues an N-ACTION indication primitive to the Performing DIMSE Service User.</para>
</listitem>
<listitem>
<para xml:id="para_0c355174-12a9-4883-b11b-da1fa3982dd0">If the operation can be performed, the Performing DIMSE Service User applies the action to the specified SOP Instance and generates a response indicating acceptance of the N-ACTION Request primitive by issuing an N-ACTION response primitive to the DIMSE Service Provider. In this case the following procedure does not apply. The Action Reply may be included in a successful response.</para>
</listitem>
<listitem>
<para xml:id="para_8ceeb8c3-f911-44ea-b037-227354a600d1">If the operation cannot be performed, then the Performing DIMSE Service User rejects the N-ACTION request by issuing an N-ACTION response primitive with the appropriate error code to the DIMSE Service Provider.</para>
</listitem>
<listitem>
<para xml:id="para_456c537b-16d6-41a2-a4c0-337c5628fea4">The DIMSE Service Provider issues an N-ACTION confirmation primitive to the Invoking DIMSE Service User, completing the N-ACTION operation.</para>
</listitem>
</orderedlist>
  <para xml:id="para_faeea985-6774-4da0-b8f9-2716b3925469">The Performing DIMSE Service User may return an N-ACTION response primitive with the status of Failed or Refused before the entire N-ACTION indication (Data Set) has been completely transmitted by the Invoking DIMSE Service User. A N-ACTION response primitive with the status of Success or Warning shall not be returned until the entire N-ACTION indication has been received by the Performing DIMSE Service User.</para>
  <note>
    <para xml:id="para_a46e3897-9e57-4b89-9d76-16902888213c">Such an occurrence of a "Failed" response is often called an early failed response.</para>
  </note>
  </section>
</section>
<section label="10.1.5" status="3" xml:id="sect_10.1.5">
    <title>N-CREATE Service</title>
  
  <para xml:id="para_6616d975-1c4b-49ac-9be5-f30fed0b4b48">The N-CREATE service is used by a DIMSE Service User to request a peer DIMSE Service User to create a new managed SOP Instance, complete with its identification and the values of its associated Attributes, and simultaneously to register its identification. It is a confirmed service.</para>
  <section label="10.1.5.1" status="4" xml:id="sect_10.1.5.1">
    <title>N-CREATE Parameters</title>
  
  <para xml:id="para_6cc90744-1c1c-40dc-b4b2-9635e8ad1774">
<xref linkend="table_10.1-5" xrefstyle="select: label"/> lists the parameters for this service.</para>
    <table frame="box" label="10.1-5" rules="all" xml:id="table_10.1-5">
    <caption>N-CREATE Parameters</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_1e9d0fe9-fff5-42dd-bc86-e8003cfc0d54">
          <emphasis role="bold">DIMSE Parameter Name</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_cbf1df9a-3eeb-4858-9b4c-789202afcdfd">
          <emphasis role="bold">Req/Ind</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_e08140b2-d369-47c8-a16b-044dbbf654e9">
          <emphasis role="bold">Rsp/Conf</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b3eebf57-8268-4b14-8b43-a7a9446fb203">Message ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1f45eb2b-0718-4ded-baba-75c4dfc38c80">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1b97286d-fbfe-4912-9da1-22ee8466544a">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3ac46768-27a3-4d06-93d9-964b14cf3e96">Message ID Being Responded To</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1ac753bb-832f-423c-acc2-5740079656dd">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8e87bd92-cf90-4f01-b51b-9b6b4d4e1d60">M</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c176df9d-3af1-40d1-8710-e5c2c308893a">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_62d1e8b5-d876-4563-baa4-ab1655f2c8a1">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ce4b8b90-6852-45ca-8a9c-93e154db0fca">U(=)</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a31f3598-0eab-4dac-90b8-50eeb3b1fb4c">Affected SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f28ec01c-fde8-46a2-b436-dcad365d7627">U</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f0b66ea6-e116-44d2-8893-d7dd32d38852">C</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5aadfdb8-fee7-4b27-bb52-d5aa324e4587">Attribute List</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a6bfdd9a-31e4-4f8f-9fb9-e7de3923f565">U</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_866c6752-bbe8-4c8a-b2d6-e4b3b23c9a01">U</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c0158929-e8dd-4e73-9614-f8cd63d2bee0">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_64647373-1a7c-44b3-9a50-14b7f3fe48f1">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f888c7a6-8856-4563-ab32-f5c49af98785">M</para>
      </td>
    </tr>
    </tbody>
  </table>
  <section label="10.1.5.1.1" status="5" xml:id="sect_10.1.5.1.1">
    <title>Message ID</title>
  
  <para xml:id="para_5537cbef-4e18-40da-84b2-a6b3fb9dabfb">This parameter identifies the operation. It is used to distinguish this operation from other notifications or operations that the DIMSE Service Provider may have in progress. No two identical values for the Message ID (0000,0110) shall be used for outstanding operations or notifications.</para>
  <note>
    <para xml:id="para_4acdd52c-19a8-4614-93cc-a052687b8c9b">The Message ID (0000,0110) is recommended to be unique within the scope of an Association, to support debug procedures.</para>
  </note>
  </section>
<section label="10.1.5.1.2" status="5" xml:id="sect_10.1.5.1.2">
    <title>Message ID Being Responded To</title>
  
  <para xml:id="para_dca2bc08-0446-4a86-980e-7f928947f135">This parameter specifies the Message ID (0000,0110) of the operation request/indication to which this response/confirmation applies.</para>
  </section>
<section label="10.1.5.1.3" status="5" xml:id="sect_10.1.5.1.3">
    <title>Affected SOP Class UID</title>
  
  <para xml:id="para_b1b85388-60db-4418-8b81-fd022de75839">For the request/indication, this parameter specifies the SOP Class of the new SOP Instance that is to be created by the Performing DIMSE Service User. The Performing DIMSE Service User assigns to the new SOP Instance, a set of Attribute Values as specified by the definition of its SOP Class. For the response/confirmation, this parameter specifies the SOP class of the SOP Instance that was created. It may be included in the response/confirmation. If included in the response/confirmation, this parameter shall be equal to the value in the request/indication.</para>
  </section>
<section label="10.1.5.1.4" status="5" xml:id="sect_10.1.5.1.4">
    <title>Affected SOP Instance UID</title>
  
  <para xml:id="para_6d4fa260-c994-4bad-8b8c-86254007eb21">For the request/indication, this parameter specifies the SOP Instance that is used by the Performing DIMSE Service User. If the SOP Instance UID is not supplied by the Invoking DIMSE Service User, then the Performing DIMSE Service User assigns a value to this identification of instance. For the response/confirmation, this parameter may only be included in the success response/confirmation and shall be included if it is not supplied by the Invoking DIMSE Service User.</para>
  </section>
<section label="10.1.5.1.5" status="5" xml:id="sect_10.1.5.1.5">
    <title>Attribute List</title>
  
  <para xml:id="para_69f2b2d4-9686-446e-a503-85f679344484">When this parameter is supplied by the Invoking DIMSE Service User, it contains a set of Attribute identifiers and values that the Performing DIMSE Service User is to assign to the new managed SOP Instance. When returned by the Performing DIMSE Service User in the success response/confirmation, this parameter contains the complete list of all Attribute identifiers and values that were assigned to the new managed SOP Instance.</para>
  </section>
<section label="10.1.5.1.6" status="5" xml:id="sect_10.1.5.1.6">
    <title>Status</title>
  
  <para xml:id="para_a091bbd0-43b4-4cca-a376-6dfdfc6ac5a4">This parameter contains the error or success notification for the operation. It shall be included by the Performing DIMSE Service User in any response/confirmation. The following type of status may occur (see also <xref linkend="chapter_C" xrefstyle="template:Annex %n"/>):</para>
<itemizedlist>
  <listitem>
<para xml:id="para_d7a4d438-ac76-4da0-b101-31b0f64687e2">Duplicate invocation (0210H) - This indicates that the Message ID (0000,0110) specified is allocated to another notification or operation.</para>
</listitem>
  <listitem>
<para xml:id="para_5fef87c0-98a0-460a-aa3c-7627aea879d9">Duplicate SOP Instance (0111H) - This indicates that the new managed SOP Instance Value supplied by the Invoking DIMSE Service User was already registered for a managed SOP Instance of the specified SOP Class.</para>
</listitem>
  <listitem>
<para xml:id="para_95c8155f-de45-4be3-86ee-fb827c0e039b">Invalid Attribute Value (0106H) - This indicates that the Attribute Value specified was out of range or otherwise inappropriate.</para>
</listitem>
  <listitem>
<para xml:id="para_f5022213-1479-440b-902f-3ea674a205f1">Attribute Value out of range (0116H) - This indicates that the Attribute Value specified was out of range or otherwise inappropriate. The SCP will apply a default value or will not include the attribute in the created instance.</para>
</listitem>
  <listitem>
<para xml:id="para_ccc14c5e-ab2c-4c5a-a488-ce7aca0eb0b8">Invalid SOP Instance (0117H) - This indicates that the SOP Instance UID specified implied a violation of the UID construction rules.</para>
</listitem>
  <listitem>
<para xml:id="para_1a21ad5f-6900-44af-8981-b4abd5c588cb">Missing Attribute (0120H) - This indicates that a required Attribute was not supplied.</para>
</listitem>
  <listitem>
<para xml:id="para_e1970518-5e99-4937-bd5d-68e593a7299f">Missing Attribute Value (0121H) - This indicates that a required Attribute Value was not supplied and a default value was not available.</para>
</listitem>
  <listitem>
<para xml:id="para_9145ed6c-e06d-4c85-930a-736dbe0a74b5">Mistyped argument (0212H) - This indicates that one of the parameters supplied has not been agreed for use on the Association between the DIMSE Service Users.</para>
</listitem>
  <listitem>
<para xml:id="para_e0862c63-426e-4d37-b2a4-b16fdf4a268c">No such Attribute (0105H) - This indicates that the Tag for the specified Attribute was not recognized.</para>
</listitem>
  <listitem>
<para xml:id="para_d1963d97-d707-4e70-a618-f2a60870f238">Attribute List warning (0107H) - This indicates that one or more specified Attributes were not recognized and not included in the created instance.</para>
</listitem>
  <listitem>
<para xml:id="para_2214f90c-300c-4a89-b3a2-35bba4bf66bb">No such SOP Class (0118H) - This indicates that the SOP Class was not recognized.</para>
</listitem>
  <listitem>
<para xml:id="para_b9e95c90-5d8f-41cd-a09a-e723d201977c">Processing Failure (0110H) - This indicates that a general failure in processing the operation was encountered.</para>
</listitem>
  <listitem>
<para xml:id="para_994643c9-8011-4265-af0c-abf4de393180">Resource limitation (0213H) - This indicates that the operation was not performed due to resource limitation.</para>
</listitem>
  <listitem>
<para xml:id="para_dcdb980a-b108-4d68-9fae-c4eead16ac1c">Success (0000H) - This indicates q successful operation.</para>
</listitem>
  <listitem>
<para xml:id="para_31c3a6b6-ed51-4845-bc52-c346b59526bc">Unrecognized operation (0211H) - This indicates that the operation is not one of those agreed between the DIMSE Service Users.</para>
</listitem>
  <listitem>
<para xml:id="para_3d8ff9f6-f989-4107-bdaa-f617ac6c1f54">Refused: Not authorized (0124H) - This indicates that the peer DIMSE Service User was not authorized to invoke the operation.</para>
</listitem>
  <listitem>
      <para xml:id="para_5730b3b7-708b-4f6b-be71-dedb38e32078">Failed (Status value is Service Class specific) - This indicates that no instance was created by the Performing DIMSE Service User.</para>
  </listitem>
  <listitem>
      <para xml:id="para_42d0b9db-8c3d-4eba-a782-1b5e54e84b1b">Warning (Status value is Service Class specific) - This indicates that the Performing DIMSE Service User created an Instance but did not perform all specified operations.</para>
  </listitem>
  </itemizedlist>
</section>
</section>
<section label="10.1.5.2" status="4" xml:id="sect_10.1.5.2">
    <title>N-CREATE Service Procedures</title>
  
  <para xml:id="para_d878b9db-ed00-45d0-91b2-140481494667">The following N-CREATE procedures apply:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_1b6c1067-9e30-461e-97d4-5c341e8a4253">The Invoking DIMSE Service User requests the creation and registration of a new managed SOP Instance by issuing an N-CREATE Request primitive to the DIMSE Service Provider.</para>
</listitem>
<listitem>
<para xml:id="para_767984a6-61e1-41bf-aad2-a9693fe5716e">The DIMSE-service provider issues an N-CREATE indication primitive to the Performing DIMSE Service User.</para>
</listitem>
<listitem>
<para xml:id="para_98c4d99e-e556-4818-a199-21c8f8572622">If the operation can be performed, the Performing DIMSE Service User creates and registers the new managed SOP Instance and generates a response indicating acceptance of the N-CREATE Request primitive by issuing an N-CREATE response primitive to the DIMSE Service Provider. In this case the following procedure does not apply.</para>
</listitem>
<listitem>
<para xml:id="para_eb5e8867-89f4-4bfd-8121-76a8089aa97d">If the operation cannot be performed, then the Performing DIMSE Service User rejects the N-CREATE request by issuing an N-CREATE response primitive with the appropriate error code to the DIMSE Service Provider.</para>
</listitem>
<listitem>
<para xml:id="para_fab6bfd7-e2c5-4d8a-8b6c-fa6c579aa782">The DIMSE Service Provider issues an N-CREATE confirmation primitive to the Invoking DIMSE Service User, completing the N-CREATE operation.</para>
</listitem>
</orderedlist>
  <para xml:id="para_0f8a593d-cbfc-495d-bbd0-7e4a4d1f908a">The Performing DIMSE Service User may return an N-CREATE response primitive with the status of Failed or Refused before the entire N-CREATE indication (Data Set) has been completely transmitted by the Invoking DIMSE Service User. A N-CREATE response primitive with the status of Success or Warning shall not be returned until the entire N-CREATE indication has been received by the Performing DIMSE Service User.</para>
  <note>
    <para xml:id="para_e713b3ab-d5af-4385-8245-573c7f90a23b">Such an occurrence of a "Failed" response is often called an early failed response.</para>
  </note>
  </section>
</section>
<section label="10.1.6" status="3" xml:id="sect_10.1.6">
    <title>N-DELETE Service</title>
  
  <para xml:id="para_fab1cbd6-fac7-4473-a1ca-67fb7d212cf7">The N-DELETE service is used by an Invoking DIMSE Service User to request a peer DIMSE Service User to delete a managed SOP Instance and to de-register its identification. It is a confirmed service.</para>
  <section label="10.1.6.1" status="4" xml:id="sect_10.1.6.1">
    <title>N-DELETE Parameters</title>
  
  <para xml:id="para_6f3e7337-31db-4530-937a-8cbf931d1a54">
<xref linkend="table_10.1-6" xrefstyle="select: label"/> lists the parameters for this service.</para>
    <table frame="box" label="10.1-6" rules="all" xml:id="table_10.1-6">
    <caption>N-DELETE Parameters</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_0cf1df91-150b-4bfe-9a12-e2b1150c7909">
          <emphasis role="bold">DIMSE Parameter Name</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_1aaac5d7-803d-4b37-9ad3-e8c999a4b992">
          <emphasis role="bold">Req/Ind</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_e68a89f3-502d-422e-abd9-70ca8f67ed5b">
          <emphasis role="bold">Rsp/Conf</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3163868a-86d3-4072-b1d7-3f47cb15ef0f">Message ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6ab2e006-2de6-4160-8239-3f4dc819ee7d">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_99348543-37be-48d0-a56b-f9da5c725b84">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_70580e02-ff6d-4192-bf63-eb581afea73d">Message ID Being Responded To</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0dc919ba-9ce4-49da-a6ea-27aa4227f498">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d7bd8810-f286-4b6a-ac30-7136100b635e">M</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_90771057-7623-47c8-8cd8-4ac254b7eab4">Requested SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_fb38a99c-9c0b-4c41-99ed-2511e0a60ad0">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8890c50c-8098-40bb-8ec7-79c4af73f50f">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6545bac2-6a07-48de-8643-ae407cc5cc17">Requested SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b4485f40-639d-4a06-9883-31b31a29ce15">M</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4aa11dff-2dc2-4e95-8d7b-7e115ab834ad">-</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_4f609ae7-c070-442d-8707-e34e104e90e9">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_57a25bc5-810e-4ee7-90c1-d12f25e07d67">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8e8ea90d-892b-413b-8dcd-d24faabddcce">U</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e2f8f13d-dde6-412c-ac7c-b4f6fbe1debd">Affected SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5103741d-29e7-4088-a819-41074fc41e8c">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8fdf37c7-55d5-423f-8853-4357470c8510">U</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_edf83d78-bd88-4c5e-8361-efdf63fbb5c8">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4f69d449-6b9a-41a8-aeb2-ef74e0305818">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b4eb2c93-14eb-4ce9-a086-0d881d889242">M</para>
      </td>
    </tr>
    </tbody>
  </table>
  <section label="10.1.6.1.1" status="5" xml:id="sect_10.1.6.1.1">
    <title>Message ID</title>
  
  <para xml:id="para_c7fd55d5-f8b1-486e-b08e-b44c488ca344">This parameter identifies the operation. It is used to distinguish this operation from other notifications or operations that the DIMSE Service Provider may have in progress. No two identical values for the Message ID (0000,0110) shall be used for outstanding operations or notifications.</para>
  <note>
    <para xml:id="para_c516a6ba-88da-4be0-b8fc-d734d7e07828">The Message ID (0000,0110) is recommended to be unique within the scope of an Association, to support debug procedures.</para>
  </note>
  </section>
<section label="10.1.6.1.2" status="5" xml:id="sect_10.1.6.1.2">
    <title>Message ID Being Responded To</title>
  
  <para xml:id="para_e8aa87aa-6862-4aa9-abb9-cc57a1e1e23c">This parameter specifies the Message ID (0000,0110) of the operation request/indication to which this response/confirmation applies.</para>
  </section>
<section label="10.1.6.1.3" status="5" xml:id="sect_10.1.6.1.3">
    <title>Requested SOP Class UID</title>
  
  <para xml:id="para_d19d60e7-8e82-406c-b619-9b1f97a79b01">This parameter specifies the SOP Class that is to be deleted.</para>
  </section>
<section label="10.1.6.1.4" status="5" xml:id="sect_10.1.6.1.4">
    <title>Requested SOP Instance UID</title>
  
  <para xml:id="para_c48fe560-1d19-4e6e-8884-e75d8aef4f20">This parameter specifies the SOP Instance that is to be deleted.</para>
  </section>
<section label="10.1.6.1.5" status="5" xml:id="sect_10.1.6.1.5">
    <title>Affected SOP Class UID</title>
  
  <para xml:id="para_56f30fab-c05d-4fca-9997-90aa9102ce04">This parameter may be included in the response/confirmation. If included in the response/confirmation, this parameter shall be equal to the parameter value used in the request/indication.</para>
  </section>
<section label="10.1.6.1.6" status="5" xml:id="sect_10.1.6.1.6">
    <title>Affected SOP Instance UID</title>
  
  <para xml:id="para_6341ba63-2b78-4105-a47a-d91b85386a78">This parameter specifies the SOP Instance that was deleted. It may be included in any response/confirmation and when included shall be equal to the Requested SOP Instance UID (0000,1001) parameter value used in the invocation.</para>
  </section>
<section label="10.1.6.1.7" status="5" xml:id="sect_10.1.6.1.7">
    <title>Status</title>
  
  <para xml:id="para_b20afe09-91e6-42f4-a46a-896c3434982e">This parameter contains the error or success notification for the operation. It shall be included by the Performing DIMSE Service User in any response/confirmation. The following types of status may occur (see also <xref linkend="chapter_C" xrefstyle="template:Annex %n"/>):</para>
<itemizedlist>
  <listitem>
<para xml:id="para_946ab28d-f4a6-4ffc-a0d8-5fca8f3c2931">Class-Instance conflict (0119H) - This indicates that the specified SOP Instance is not a member of the specified SOP Class</para>
</listitem>
  <listitem>
<para xml:id="para_7c74ca7b-23ab-409e-8bcd-c07acedaa703">Duplicate invocation (0210H) - This indicates that the Message ID (0000,0110) specified is allocated to another notification or operation</para>
</listitem>
  <listitem>
<para xml:id="para_de29b350-bbf7-4e15-91ea-8fc1673edc3e">Invalid SOP Instance (0117H) - This indicates that the SOP Instance UID specified implied a violation of the UID construction rules</para>
</listitem>
  <listitem>
<para xml:id="para_711c5fdb-903a-45c2-8362-91565198cf57">Mistyped argument (0212H) - This indicates that one of the parameters supplied has not been agreed for use on the Association between the DIMSE Service Users</para>
</listitem>
  <listitem>
<para xml:id="para_f98ec44e-809f-4c5e-9ef6-8520764fd5a8">No such SOP Class (0118H) - This indicates that the SOP Class was not recognized</para>
</listitem>
  <listitem>
<para xml:id="para_1e6ea131-1b46-43b0-a02c-b9c630f05777">No such SOP Instance (0112H) - This indicates that the SOP Instance was not recognized</para>
</listitem>
  <listitem>
<para xml:id="para_236dee26-8cce-4ee1-83eb-ccf04bce8b8c">Processing Failure (0110H) - This indicates that a general failure in processing the operation was encountered</para>
</listitem>
  <listitem>
<para xml:id="para_c34a8d3e-71a1-43cd-9ddd-d8a98de9462a">Resource limitation (0213H) - This indicates that the operation was not performed due to resource limitation</para>
</listitem>
  <listitem>
<para xml:id="para_fccef240-ce91-4893-9dd1-db69c42e55dd">Success (0000H) - This indicates a successful operation</para>
</listitem>
  <listitem>
<para xml:id="para_f2a6a785-3ea7-464b-9bf2-16cc4043cb39">Unrecognized operation (0211H) - This indicates that the operation is not one of those agreed between the DIMSE Service Users</para>
</listitem>
  <listitem>
      <para xml:id="para_6a277702-e912-4973-ad75-35ac2927655e">Refused: Not authorized (0124H) - This indicates that the peer DIMSE Service User was not authorized to invoke the operation.</para>
</listitem>
</itemizedlist>
  </section>
</section>
<section label="10.1.6.2" status="4" xml:id="sect_10.1.6.2">
    <title>N-DELETE Service Procedures</title>
  
  <para xml:id="para_645c9446-75ff-44a0-9c09-453390130188">The following N-DELETE procedures apply:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_33442511-81ee-49ff-a3cc-4bd65b493995">The Invoking DIMSE Service User requests the Performing DIMSE Service User to delete a managed SOP Instance by issuing an N-DELETE Request primitive to the DIMSE Service Provider.</para>
</listitem>
<listitem>
<para xml:id="para_bcbd346a-c128-46a7-adac-f2ceff141068">The DIMSE-service provider issues an N-DELETE indication primitive to the Performing DIMSE Service User.</para>
</listitem>
<listitem>
<para xml:id="para_4fd98e52-7981-4453-8485-b8613fb9cc81">If the operation can be performed, the Performing DIMSE Service User deletes the specified managed SOP Instance and generates a response indicating acceptance of the N-DELETE Request primitive by issuing an N-DELETE response primitive to the DIMSE Service Provider. In this case the following procedure does not apply.</para>
</listitem>
<listitem>
<para xml:id="para_d8bc6bc3-5768-4591-bf8b-f824d492b47f">If the operation cannot be performed, then the Performing DIMSE Service User rejects the N-DELETE request by issuing an N-DELETE response primitive with the appropriate error code to the DIMSE Service Provider.</para>
</listitem>
<listitem>
<para xml:id="para_3f12aa17-47c8-48c5-84ab-443e8476e015">The DIMSE Service Provider issues an N-DELETE confirmation primitive to the Invoking DIMSE Service User, completing the N-DELETE operation.</para>
</listitem>
</orderedlist>
  </section>
</section>
</section>
<section label="10.2" status="2" xml:id="sect_10.2">
    <title>Sequencing</title>
  
  <section label="10.2.1" status="3" xml:id="sect_10.2.1">
    <title>Types of Services</title>
  
  <para xml:id="para_ff8234dc-9140-489d-96e1-71277c71b18d">All operation and notifications shall be confirmed services.</para>
  </section>
<section label="10.2.2" status="3" xml:id="sect_10.2.2">
    <title>Usage Restrictions</title>
  
  <para xml:id="para_10efc674-068f-4f47-a284-22b3191901d6">These services may only be invoked within the context of an established Association.</para>
  </section>
<section label="10.2.3" status="3" xml:id="sect_10.2.3">
    <title>Disrupted Procedures</title>
  
  <para xml:id="para_4efbd20d-6ddd-4f9c-9a4f-1903bc751f3f">These services do not disrupt any other service procedure.</para>
  </section>
<section label="10.2.4" status="3" xml:id="sect_10.2.4">
    <title>Disrupting Procedures</title>
  
  <para xml:id="para_85ee5105-7567-42b1-895c-23d87e3fb8ec">These services are disrupted by the A-ABORT service procedure.</para>
  </section>
</section>
<section label="10.3" status="2" xml:id="sect_10.3">
    <title>Protocol</title>
  
  <para xml:id="para_cc9aaa8d-18d6-4116-8fd3-9bd73ab2c61f">This section specifies the protocol necessary to perform the set of DIMSE-N operations and notifications. The Value Representations (VR) specified in the following tables shall be encoded as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>.</para>
  <section label="10.3.1" status="3" xml:id="sect_10.3.1">
    <title>N-EVENT-REPORT Protocol</title>
  
      <para xml:id="para_e2803b81-0d2a-41e5-8698-df13861a82e7">The information necessary for the N-EVENT-REPORT Request and N-EVENT-REPORT Indication DIMSE-N primitives are conveyed in the N-EVENT-REPORT-RQ Message. The information necessary for the N-EVENT-REPORT response and confirmation DIMSE-N primitives are conveyed in the N-EVENT-REPORT-RSP Message.</para>
  <section label="10.3.1.1" status="4" xml:id="sect_10.3.1.1">
    <title>N-EVENT-REPORT-RQ</title>
  
  <para xml:id="para_2644673f-3913-486a-9508-ae4abe13f271">The N-EVENT-REPORT-RQ Message contains fields as defined in <xref linkend="table_10.3-1" xrefstyle="select: label"/>. Each field shall conform to DICOM encoding and Value Representation as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>. Fields are required as specified in the N-EVENT-REPORT service definition unless otherwise noted in <xref linkend="table_10.3-1" xrefstyle="select: label"/>. Fields not specified in the N-EVENT-REPORT service definition but present in <xref linkend="table_10.3-1" xrefstyle="select: label"/> are required by the DIMSE-N protocol.</para>
    <table frame="box" label="10.3-1" rules="all" xml:id="table_10.3-1">
    <caption>N-EVENT-REPORT-RQ Message Fields</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_81aad79b-e5eb-4cf2-8cfa-645c809933d5">
          <emphasis role="bold">Message Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_b0212f6b-387b-4f79-aeb4-bc110cae1db1">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_f5a5397e-ee2a-4e5d-bc10-ad8e2dd66eac">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_2d9666f4-c211-43b7-8dc4-0f520b2cae08">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_01d50297-4d29-4054-951c-d5df1e9f7c1d">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_ef20af84-4180-4310-a9e6-9d48f479c7d1">Command Group Length</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_473227ec-2579-438f-a2d0-fe7feae83b7d">(0000,0000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_acaddf5f-0edd-4a3b-8dfd-cff50fea68e0">UL</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_aa001eae-2baf-48d3-996c-78a76dd6b888">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_bb525c15-c623-4a95-9fb9-7d6bf8a91ed5">The even number of bytes from the end of the value field to the beginning of the next group.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d5d797fb-425b-4796-8249-920ba5fa1adb">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_463d4282-ea35-4005-8ecd-221d5d25496d">(0000,0002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_62784b79-85b6-49cf-93ab-832aebcdaaf1">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7069fa03-8610-4325-98be-74e3fea119f7">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_19fc6e69-425e-4ed8-94b2-4222501b1368">SOP Class UID of the SOP Instance for which this event occurred.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_57181c56-e502-4cdc-a01a-5621a410db3f">Command Field</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a20971e1-7904-4faf-82fd-0c88dafba016">(0000,0100)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7721a05c-fd68-4faf-92e0-7010904f1527">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e2db4dd2-6a2c-487a-a2f6-282d511ecf73">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_406edbab-5c75-4073-99fe-ce11a6e5ef75">This field distinguishes the DIMSE-N notification conveyed by this Message. The value of this field shall be set to 0100H for the N-EVENT-REPORT-RQ Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_07f8483a-f76b-4c54-9283-89c978944d1e">Message ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9dbc91a6-62ce-4d62-8401-7b6c7bffd880">(0000,0110)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e13b68ca-efaa-4230-982d-28176d076ebc">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_80dc50e2-5857-4b5d-88a6-0ca0dbcdef19">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_765c1c8c-ad42-49a8-89d8-dc3a0af1cb23">Implementation-specific value that distinguishes this Message from other Messages.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e8dd7620-6d0c-4180-8237-25d440106608">Command Data Set Type</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_76f06e94-2af6-4ab7-9ba6-10a30bb010a1">(0000,0800)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5055baf9-4c49-4b9c-bc27-7590d6dd40d3">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6e97f801-5c56-4acf-9c38-afc44aa59103">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f3b386e1-f64f-4134-8b7e-c1665057dfcf">This field indicates if a Data Set is present in the Message. This field shall be set to the value of 0101H if no Data Set is present; any other value indicates a Data Set is included in the Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_dad87a0f-618b-46e3-9908-4e1aaca66133">Affected SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_32552e5f-5854-4e1f-92de-13d1f58b6715">(0000,1000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_97f59a7c-2f2e-45c6-ace6-ad6e9625b6cf">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_437a2538-876b-43e8-942c-b1099d83a046">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c33a7987-acaa-4d86-8377-1b6135c96879">Contains the UID of the SOP Instance for which this event occurred.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_ffb457da-fe82-48f8-9283-e8a7228c00a5">Event Type ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_866329ed-4c10-40fe-9de6-8964a1844123">(0000,1002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6e162b51-4747-4eea-bd13-5bd8af184686">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_04b6187b-f220-493c-b616-186634faafbd">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0c12555c-4a15-4e8a-acf0-cf20e4e6165f">Values for this field are application-specific.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_8220d2a7-e16c-4605-a2de-3f4e80cd8f85">Event Information</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_bffa2d2b-f466-4f41-b5ef-2b87894bb346">(no tag)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_12c250a5-e299-42f3-b8d2-728afae94504">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ea7b8d8b-5b6b-46ae-897f-67c979fa1e59">-</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0c25ec3d-ebca-4ece-9fe4-081c6e4e30ae">Application-specific Data Set containing additional information related to the operation.</para>
      </td>
    </tr>
    </tbody>
  </table>
  <note>
    <orderedlist numeration="arabic">
      <listitem>
        <para xml:id="para_2402205a-07a0-4a7f-8365-d1ba730a3902">Service Class Specifications contained in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/> defines the values needed for the Event Type ID parameter.</para>
      </listitem>
      <listitem>
        <para xml:id="para_c3747c05-4ac0-4eaa-8dfe-947c641545c3">Service Class Specifications contained in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/> defines the Data Set needed for the Event Information parameter.</para>
      </listitem>
    </orderedlist>
  </note>
  </section>
<section label="10.3.1.2" status="4" xml:id="sect_10.3.1.2">
    <title>N-EVENT-REPORT-RSP</title>
  
  <para xml:id="para_a935c13d-555d-44c1-aa60-83de051c9dd5">The N-EVENT-REPORT-RSP Message contains fields as defined in <xref linkend="table_10.3-2" xrefstyle="select: label"/> and <xref linkend="chapter_C" xrefstyle="template:Annex %n"/>. Each field shall conform to DICOM encoding and Value Representation as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>. Fields are required as specified in the N-EVENT-REPORT service definition unless otherwise noted in <xref linkend="table_10.3-2" xrefstyle="select: label"/>. Fields not specified in the N-EVENT-REPORT service definition but present in <xref linkend="table_10.3-2" xrefstyle="select: label"/> are required by the DIMSE-N protocol.</para>
    <table frame="box" label="10.3-2" rules="all" xml:id="table_10.3-2">
    <caption>N-EVENT-REPORT-RSP Message Fields</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_226a0c07-9051-48a5-a7bc-38d44fdd7175">
          <emphasis role="bold">Message Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_66ab0861-8225-4ee2-bcc5-678f2963117e">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_86911630-f9c3-4239-a684-b45279c325ff">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_33a87a27-0d8d-44b3-bced-bf26f51384f6">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_f26b5f93-5b8b-4428-8a59-68cfe946a17c">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_da88411b-0e3b-4cc2-9494-1c2640237736">Command Group Length</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b523b9df-05b3-4b52-99a9-1d54bac429a1">(0000,0000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c1391b03-4a51-448d-9cbd-b07747d9da42">UL</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4088ad71-6c8e-42c7-aab1-def0ac88d67a">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e68a246e-0f24-4783-b8b2-e48aafbb5967">The even number of bytes from the end of the value field to the beginning of the next group.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6bb13197-2c9c-48e7-aab3-db7cd406e028">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b5021d7d-7d0f-44e1-996b-b51890993232">(0000,0002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ebab19eb-14b9-49aa-bf56-365eb8600e4a">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5dd77970-6a82-48cf-b747-2f7d3fbd5fc8">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_daa233ed-1468-4b67-8292-da24ce2ddbed">SOP Class UID of the SOP Instance for which this event occurred.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_38101f3d-d185-4de5-bee5-36bb06d3a928">Command Field</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b0e9f4d1-6962-4177-ba17-9a3c9da3f3c7">(0000,0100)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_78876f4e-3837-4ba4-9fd5-e99ef7bfac1c">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_410ea04a-2de2-4dff-b916-b21136374a53">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_2b4a2691-dbe6-49c6-bc88-6b188ffd1946">This field distinguishes the DIMSE-N operation conveyed by this Message. The value of this field shall be set to 8100H for the N-EVENT-REPORT-RSP Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5ba436a8-eb8c-470f-adce-86103e427cb9">Message ID Being Responded To</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0507d8a3-a1d7-4cc7-8418-008facff021e">(0000,0120)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6670d3ed-839f-4d42-bdcb-160a24241f64">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_69d33b9c-8038-4722-b334-d4547d1e8955">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_8ac01ba0-92b7-465c-b691-76408f7eac3e">Shall be set to the value of the Message ID (0000,0110) field used in associated N-EVENT-REPORT-RQ Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_2f63815e-a960-4315-9339-f5084060e942">Command Data Set Type</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_06f53d57-93a1-45a3-bbe4-a06e3926b004">(0000,0800)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0f2bd334-f1f1-4ddf-8183-5acb97077984">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8da33604-d2d8-4e93-ac22-ff636a6b217e">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_941a5170-0c03-4e72-9239-508ffca2049d">This field indicates if a Data Set is present in the Message. This field shall be set to the value of 0101H if no Data Set is present; any other value indicates a Data Set is included in the Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_44b7be78-ee16-4f2e-a33e-44416ea49219">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9222091c-7c80-4667-a210-63f117451fd0">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_86754ab1-cef5-4d42-8fac-805fc62c7dbb">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c8467fde-6089-4645-8295-e716a0c95dfd">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_17be20e4-79b8-4675-bd7b-5b25809670e5">The value of this field depends upon the status type. <xref linkend="chapter_C" xrefstyle="template:Annex %n"/> defines the encoding of the status types defined in the service definition.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_7555ae88-7a8b-43c3-86e9-0c85c4536f34">Affected SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0c01db93-6f1d-403b-9fcb-bf540d81a32e">(0000,1000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a5faddbb-3a10-46db-abe1-7c4dbcd2b2ed">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_014be727-16d7-496b-858f-0003878224e3">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a62cef32-4688-4190-88ee-a5fb72e46ea2">Contains the UID of the SOP Instance for which this event occurred.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5b7247c6-0059-45c9-aa6b-33fe32ad1ab3">Event Type ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_aee6acee-b404-4395-a941-2db0ad28155d">(0000,1002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d5f4806a-28e7-485b-a944-2c5c77b473ae">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8b85a74a-58d8-43f3-b391-5e6a745fdc1c">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_2e635cf1-e96e-420f-aba3-68d4136d3fa6">Values for this field are application-specific.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5971afe3-9398-4ee9-a2f3-4a0d853be9e6">Event Reply</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a3d5c5ef-9913-4d02-9f0e-92e440e7c9a4">(no tag)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ad6ad654-8411-4e0b-b54c-cba84e993668">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_30d62825-1637-469b-8e8f-1d2f6d3d7804">-</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d47edb5e-7a35-497e-add3-baca631bf407">Application-specific Data Set containing additional information related to the operation.</para>
      </td>
    </tr>
    </tbody>
  </table>
  <note>
    <orderedlist numeration="arabic">
      <listitem>
        <para xml:id="para_17d9fc4c-ab9f-4075-afda-0318fc37416a">Service Class Specifications contained in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/> defines the values needed for the Event Type ID parameter.</para>
      </listitem>
      <listitem>
        <para xml:id="para_66a0dc79-d7ec-459b-9eac-0a637de292fe">Service Class Specifications contained in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/> defines the Data Set needed for the Event Reply parameter related to each defined Event Type ID.</para>
      </listitem>
    </orderedlist>
  </note>
  </section>
<section label="10.3.1.3" status="4" xml:id="sect_10.3.1.3">
    <title>N-EVENT-REPORT Protocol Procedures</title>
  
  <para xml:id="para_01a27337-cbc3-4625-b8ed-e6597ed9beb8">The N-EVENT-REPORT reporting procedures are initiated by the Invoking DIMSE Service User issuing an N-EVENT-REPORT Request primitive. On receipt of the N-EVENT-REPORT Request primitive the DIMSE-N protocol machine shall:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_2bf4cc25-ac63-4022-818a-59c9e59b4c69">construct a Message conveying the N-EVENT-REPORT-RQ</para>
</listitem>
  <listitem>
<para xml:id="para_1702c17b-2a55-49a6-9bd9-d0a8b7c5aa86">send the Message using the P-DATA request service (see 8.1)</para>
</listitem>
</itemizedlist>
  <para xml:id="para_be837c84-06c3-4687-8f79-cfccf3de42ce">On receipt of a Message conveying an N-EVENT-REPORT-RQ the DIMSE-N protocol machine shall issue an N-EVENT-REPORT indication primitive to the Performing DIMSE Service User.</para>
  <para xml:id="para_2c97e99e-1c4b-40bf-b019-e9cdb46b799a">On receipt of the N-EVENT-REPORT response primitive issued by the Performing DIMSE Service User
  <emphasis role="bold">,</emphasis>the DIMSE-N protocol machine shall:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_7ae1d05e-842f-4d44-92fe-b20021facd28">construct a Message conveying the N-EVENT-REPORT-RSP</para>
</listitem>
  <listitem>
<para xml:id="para_66c99201-0363-4c2a-beeb-2514b90c8f67">send the Message using the P-DATA request service (see <xref linkend="sect_8.1" xrefstyle="select: label"/>)</para>
</listitem>
</itemizedlist>
  <para xml:id="para_d3396415-96f1-4563-a8c1-cd3b68b0f71f">On receipt of a Message conveying an N-EVENT-REPORT-RSP the DIMSE-N protocol machine shall issue an N-EVENT-REPORT confirmation primitive to the Invoking DIMSE Service User, thus completing the notification procedure.</para>
  <para xml:id="para_984c7abd-e375-4136-8c85-9b094332eef6">The Performing DIMSE Service User may return an N-EVENT-REPORT-RSP with the status of Failed or Refused before the complete N-EVENT-REPORT-RQ request Message has been completely transmitted by the Invoking DIMSE Service User (this is called an early failed response). Upon receipt of this Failed or Refused N-EVENT-REPORT-RSP the Invoking DIMSE Service User may terminate the Message before it is completely sent (i.e., set the Last Fragment bit to 1 in a Data PDV for this Message, see <xref linkend="chapter_F" xrefstyle="template:Annex %n"/>). Following this, it may invoke another operation or notification. It is a protocol violation for an Invoking DIMSE Service User to set the Last Fragment bit to 1 before an N-EVENT-REPORT-RQ Message has been completely transmitted if it has not received a Failed or Refused N-EVENT-REPORT-RSP to that request.</para>
  <note>
    <para xml:id="para_292cf5a2-5d60-456f-866c-436c980103fc">When an Association is operating in asynchronous mode, it is possible for an Invoking DIMSE Service User to transmit several Messages before a response. Therefore, while sending a Message it may receive a response to a previously transmitted Message. In this case this response is not an early failed response because the related Message has already been sent.</para>
  </note>
  </section>
</section>
<section label="10.3.2" status="3" xml:id="sect_10.3.2">
    <title>N-GET Protocol</title>
  
    <para xml:id="para_5f272152-fc90-4c27-9f34-2b76dddbf931">The information necessary for the N-GET Request and N-GET Indication DIMSE-N primitives are conveyed in the N-GET-RQ Message. The information necessary for the N-GET response and confirmation DIMSE-N primitives are conveyed in the N-GET-RSP Message.</para>
  <section label="10.3.2.1" status="4" xml:id="sect_10.3.2.1">
    <title>N-GET-RQ</title>
  
  <para xml:id="para_ccee64d3-cce5-463f-ad8d-0df01a55b5be">The N-GET-RQ Message contains fields as defined in <xref linkend="table_10.3-3" xrefstyle="select: label"/>. Each field shall conform to DICOM encoding and Value Representation as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>. Fields are required as specified in the N-GET service definition unless otherwise noted in <xref linkend="table_10.3-3" xrefstyle="select: label"/>. Fields not specified in the N-GET service definition but present in <xref linkend="table_10.3-3" xrefstyle="select: label"/> are required by the DIMSE-N protocol.</para>
    <table frame="box" label="10.3-3" rules="all" xml:id="table_10.3-3">
    <caption>N-GET-RQ Message Fields</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_3ea4dfff-183f-4cea-a434-36b4ae105120">
          <emphasis role="bold">Message Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_7f0447df-0c22-4008-a89f-0df023e56e3c">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_115100f8-e46b-465a-9a6d-360af007e00c">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_48ac039d-98da-448e-ae80-c92cf5de27ec">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_ae70ffa1-a2d0-4d3c-8787-ad7085c185ba">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_48fc38f3-3a7d-4925-ba13-cb4c043d658d">Command Group Length</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_3d81b70f-5ed9-4974-87d3-e7576ab2f011">(0000,0000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_3164c1db-a343-4126-8f1e-25a8817fe411">UL</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7f7ccc1c-19f9-42d2-9346-6242e51fe01c">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_8a55a035-c8c4-487f-8068-975554ad3b04">The even number of bytes from the end of the value field to the beginning of the next group.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_61cf7275-0705-4e26-b176-a4a0a436eda8">Requested SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_31eb9896-e9bd-4f60-8515-74095be4a259">(0000,0003)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5211b0e3-bf3c-4019-b75d-85f776177190">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2c400ae9-a6d1-4b4b-b4ad-7dd38475771f">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_ba9d273b-0913-49af-85a7-4031914f0cec">SOP Class UID of the SOP Instance for which Attribute Values are to be retrieved.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_273b8a88-6c56-4ddd-b471-3475abe96974">Command Field</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7f6fb227-01f6-4c6d-a69c-b8db7212f930">(0000,0100)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1847e406-ae88-4b32-a9ec-6ddfcde288f8">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6fb51d2b-a632-4c47-aa08-83ae60a38468">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a63b93b7-33da-43a1-972a-fed2d5874597">This field distinguishes the DIMSE-N operation conveyed by this Message. The value of this field shall be set to 0110H for the N-GET-RQ Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_85c3be46-34b2-4bc3-92c1-a3bf179603c8">Message ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_461382d9-fe37-4b3a-8b8d-31ab04007ff5">(0000,0110)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d5ce6696-b018-4c5d-844f-97b008f13100">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f8c57da6-4786-47bb-aace-7e946d3a44a4">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0aff7d60-d308-4d3d-9da4-654234f2492f">Implementation-specific value that distinguishes this Message from other Messages.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_456258ba-a3a8-474e-a2e3-672b3baaef16">Command Data Set Type</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2fd1a0f5-9c09-4a2f-b0b7-1de3ebe80e3a">(0000,0800)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_90c3b999-1d76-4dad-90aa-7a869afa0078">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_14443421-5206-4b62-b955-868af7566536">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_87308808-f6e2-4357-a60d-5f0740342315">This field indicates that no Data Set shall be present in the Message. This field shall be set to the value of 0101H).</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1364a9b8-ddb7-4dda-87cb-5c42ddc6dbf8">Requested SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1e1c783b-c598-479b-9423-182947dc475a">(0000,1001)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_41b784ef-99de-4783-b299-a2eb4b0e502e">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_966256c0-775e-4056-8b78-48f64956e134">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f1688ca5-12e1-43b3-8fdf-85d4eb9611d8">Contains the UID of the SOP Instance for which Attribute Values are to be retrieved.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_dc800d9c-542c-4c3f-b069-6f0b4a70cd9e">Attribute Identifier List</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1bcbea2e-192c-47dc-a2a1-bf44c47b7d3f">(0000,1005)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ee719548-839a-4a6a-9dcb-e6a35a6b517b">AT</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4bbd0899-269e-4ad7-9e6e-284e819e9fa2">1-n</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3eb439d0-d6f3-4f0a-86d0-7f5948190751">This field contains an Attribute Tag for each of the n Attributes applicable to the N-GET operation.</para>
      </td>
    </tr>
    </tbody>
  </table>
  </section>
<section label="10.3.2.2" status="4" xml:id="sect_10.3.2.2">
    <title>N-GET-RSP</title>
  
  <para xml:id="para_38124a53-6775-4aab-bbb7-c55c3b397370">The N-GET-RSP Message contains fields as defined in <xref linkend="table_10.3-4" xrefstyle="select: label"/> and <xref linkend="chapter_C" xrefstyle="template:Annex %n"/>. Each field shall conform to DICOM encoding and Value Representation as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>. Fields are required as specified in the N-GET service definition unless otherwise noted in <xref linkend="table_10.3-4" xrefstyle="select: label"/>. Fields not specified in the N-GET service definition but present in <xref linkend="table_10.3-4" xrefstyle="select: label"/> are required by the DIMSE-N protocol.</para>
    <table frame="box" label="10.3-4" rules="all" xml:id="table_10.3-4">
    <caption>N-GET-RSP Message Fields</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_69ef56c1-df5e-4e2c-9d86-fdbc7cfe5895">
          <emphasis role="bold">Message Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_8dbc26a0-41db-402a-8b6d-fe00fea96ab9">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_e2ea2b66-6611-44dc-a52a-f4cf33a4ea6d">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_a72aa6d6-2661-4cd2-8dbe-6489cbbe8bc2">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_c10884b4-770c-49be-a884-9b4b5c30d5de">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c6b12fb2-cf22-4ea5-a7f9-287023360d6f">Command Group Length</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_81ae793e-8bbe-46f7-ba0d-ef0a2257dde2">(0000,0000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5f4e44ed-8028-49c0-8a21-8d632d14022d">UL</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f12aad4e-6d7f-450e-ab5f-651b0b4bbb63">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_90ef74e0-75f2-459d-85bd-8c64134310f2">The even number of bytes from the end of the value field to the beginning of the next group.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_90f24705-9f43-493e-8d2b-9bfd7f843fa6">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ef5dab26-8808-45f2-8981-8ffe7c69c027">(0000,0002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_624c8520-5712-4b8c-8a48-3545158fcf0c">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_eded2031-1179-4a43-81fa-4ef3327d7384">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_7b2b660f-f22f-41c7-bfde-eb75dbc3a767">SOP Class UID of the SOP Instance for which Attribute Values are returned.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e65b81f7-a54e-4357-8810-8b108e6fb11e">Command Field</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8f2a1d2a-8dd5-4743-baa2-3fba93789652">(0000,0100)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_94a3d3fd-0a48-4055-a01c-2dd4b2545bce">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7699ec53-9fd6-4504-b70e-b94ef66d3b4d">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_dc7ab87a-cc66-4ace-b9b8-0a00b1f6446b">This field distinguishes the DIMSE-N operation conveyed by this Message. The value of this field shall be set to 8110H for the N-GET-RSP Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_2165d189-6466-4536-aebf-20f39337b118">Message ID Being Responded To</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5d6edb90-ea26-478d-a19a-7f19dd7f495f">(0000,0120)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_fd920cce-6e73-45a8-b9ee-9101652e318e">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_83c9415b-de4e-4127-8acc-b1f4bea2a53e">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5896e5d5-5a98-4af0-8513-d011dd30eb1d">Shall be set to the value of the Message ID (0000,0110) field used in associated N-GET-RQ Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_cb982724-e995-469f-b4f6-eafe87b18e69">Command Data Set Type</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f9780e39-39a5-473c-949a-0b292db17b50">(0000,0800)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f4c4f6b2-3452-4f56-94c0-102dc03a4621">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8ddcf6c3-98b6-4c58-9ca4-d1a6ef6c459e">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_fb63001e-a615-4760-a168-0758748287a0">This field indicates if a Data Set is present in the Message. This field shall be set to the value of 0101H if no Data Set is present; any other value indicates a Data Set is included in the Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_7f1a8698-4381-432e-9015-7d59afe19b99">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6d9b3f21-15cc-4eea-9b16-d3130c56e72e">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9ad44d18-136a-42ae-b436-2a32c6df11ae">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e5609b6b-9403-41b8-8e1c-58da3e99a64f">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d07bcf63-e926-4852-b960-93522aac68f0">The value of this field depends upon the status type. <xref linkend="chapter_C" xrefstyle="template:Annex %n"/> defines the encoding of the status types defined in the service definition.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_68d03bf5-e168-4a67-8c82-7719ff806829">Affected SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_62b0f5b4-1293-47fd-ae5d-04cc1d872308">(0000,1000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ae08ec96-1190-49e9-9cbf-a274212f3add">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_148ef363-774e-48de-80ff-b92b99c7c472">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_46f391b2-0e22-4c9f-ab03-0bd575522d14">Contains the UID of the SOP Instance for which Attribute Values are returned.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9879938b-237b-4395-a54d-a3abb9b1bb82">Attribute List</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_187eba59-5e09-48f3-a816-6db7653617dd">(no tag)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4e57e2a4-e095-40dd-a0f4-38f8ceb20ce2">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_deafbcb0-3ae8-4378-9c59-3f7d9c4fc0d3">-</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e6a81e67-b63d-4c7e-829b-68defd776721">T his field is encoded as a Data Set. One Data Element is encoded for each Attribute Value returned.</para>
      </td>
    </tr>
    </tbody>
  </table>
  <note>
    <para xml:id="para_e4643cc7-2a13-4865-a00e-97f4256c942d">The permitted contents of Attribute List, encoded as a series of Data Elements, are defined in the Information Object Definition (<olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>) and Service Class Specifications (<olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>).</para>
  </note>
  </section>
<section label="10.3.2.3" status="4" xml:id="sect_10.3.2.3">
    <title>N-GET Protocol Procedures</title>
  
  <para xml:id="para_eca98c04-e113-40b5-99ae-3cb6f0495d5d">The N-GET procedures are initiated by the Invoking DIMSE Service User issuing an N-GET Request primitive. On receipt of the N-GET Request primitive the DIMSE-N protocol machine shall:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_7a36f953-3741-476f-82ed-08a8694e3881">construct a Message conveying the N-GET-RQ</para>
</listitem>
  <listitem>
<para xml:id="para_84775074-42c3-4aac-bc90-82ed2368fbb5">send the Message using the P-DATA request service (see 8.1)</para>
</listitem>
</itemizedlist>
  <para xml:id="para_9fd7d844-d910-4ac8-aafc-87bb9ea9e776">On receipt of a Message conveying an N-GET-RQ the DIMSE-N protocol machine shall issue an N-GET indication primitive to the Performing DIMSE Service User.</para>
  <para xml:id="para_7e38d795-60d2-49d8-bf05-fa52806f29f1">On receipt of the N-GET response primitive, issued by the Performing DIMSE Service User, the DIMSE-N protocol machine shall:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_844752a3-5ec3-45fd-bad5-8dca265e6fbf">construct a Message conveying the N-GET-RSP</para>
</listitem>
  <listitem>
<para xml:id="para_f5533750-1a54-4ff8-8bd1-679b5da98bae">send the Message using the P-DATA request service (see 8.1)</para>
</listitem>
</itemizedlist>
  <para xml:id="para_5bd3b659-2101-482e-87c7-f9c73ca40861">On receipt of a Message conveying an N-GET-RSP the DIMSE-N protocol machine shall issue an N-GET confirmation primitive to the Invoking DIMSE Service User, thus completing the N-GET procedure.</para>
  </section>
</section>
<section label="10.3.3" status="3" xml:id="sect_10.3.3">
    <title>N-SET Protocol</title>
  
    <para xml:id="para_92c8161d-d35d-41ed-8398-afb526d7b3de">The information necessary for the N-SET Request and N-SET Indication DIMSE-N primitives are conveyed in the N-SET-RQ Message. The information necessary for the N-SET response and confirmation DIMSE-N primitives are conveyed in the N-SET-RSP Message. Fields not specified in the N-SET service definition but present in <xref linkend="table_10.3-3" xrefstyle="select: label"/> are required by the DIMSE-N protocol.</para>
  <section label="10.3.3.1" status="4" xml:id="sect_10.3.3.1">
    <title>N-SET-RQ</title>
  
  <para xml:id="para_88ec2b5b-f364-4d43-997c-e2dd542dc73c">The N-SET-RQ Message contains fields as defined in <xref linkend="table_10.3-5" xrefstyle="select: label"/>. Each field shall conform to DICOM encoding and Value Representation as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>. Fields are required as specified in the N-SET service definition unless otherwise noted in <xref linkend="table_10.3-5" xrefstyle="select: label"/>. Fields not specified in the N-SET service definition but present in <xref linkend="table_10.3-5" xrefstyle="select: label"/> are required by the DIMSE-N protocol.</para>
    <table frame="box" label="10.3-5" rules="all" xml:id="table_10.3-5">
    <caption>N-SET-RQ Message Fields</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_3b3a0aa5-49e6-4596-8cb7-e360ff218e94">
          <emphasis role="bold">Message Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_bed52819-c23e-4371-aeff-8f0534bc740a">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_0399d1f3-129b-4561-8488-229423bf47f0">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_14f0f6d9-e2f1-495d-94a1-560826c1d3ab">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_3d944d2d-e2f4-442a-962a-2b9ea91a2aee">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d2db940b-2e2a-4fa6-a050-0a0d1bdef53a">Command Group Length</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0cbb3083-52bb-41a4-ac81-8f146c41d743">(0000,0000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_de600011-f27b-453f-8975-fae242545f75">UL</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_59764069-0c51-48b5-8b16-086d212c475d">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_11c05321-6881-46d1-8307-2949944c86ff">The even number of bytes from the end of the value field to the beginning of the next group.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f00874c3-2eb8-47c7-ae43-5b3007cc9722">Requested SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e885f3b0-0475-448e-8bfa-d266826e5c63">(0000,0003)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7af54661-13f7-4f08-9465-1704959be611">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_269616f7-aeb7-4369-af1c-a8cb86be0ecd">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_18deb029-8805-4bd5-922b-9c871685694c">SOP Class UID of the SOP Instance for which Attribute Values are to be modified.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0b051dc8-5aab-4576-b7a2-0b77c1cab96f">Command Field</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a703bb28-effe-476f-a990-3953ac4c920f">(0000,0100)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ec8cd5a9-3de7-4240-b7e4-72d308b97f81">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2f0d5f8b-fd03-4cef-9804-ef690b6ddea3">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_76a73803-1d21-4cfa-b451-d8b6dde90fd4">This field distinguishes the DIMSE-N operation conveyed by this Message. The value of this field shall be set to 0120H for the N-SET-RQ Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3683a4e2-903a-492d-ac43-b3cb918e270b">Message ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9a99d9ce-fc73-4a3c-9770-2596de750c61">(0000,0110)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ca58dfe3-2b39-4d78-b62e-40bd1a2aba89">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ff1ee1e8-8039-4638-aa5c-78e76a7a0e6a">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_ef6f7d64-4f1c-4c6e-be32-6e925e1159ca">Implementation-specific value that distinguishes this Message from other Messages.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_2067ef85-c2e5-4c9b-b09d-219cb9e44e3a">Command Data Set Type</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9610a855-08c3-4ebc-9362-6a8c576d7ec9">(0000,0800)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_89591021-d6b1-42cf-8858-bd6298d82281">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_11da36f6-0b07-4397-ae67-08af9f500416">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_33ec4fe5-cccb-4c04-b2a0-5ffb1fc6e585">This field indicates that a Data Set is present in the Message. It shall be set to any value other than 0101H (Null).</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0a71e3ec-ba22-45c7-b8da-4524179283fc">Requested SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ca7f773f-4c90-4922-a377-b3f358c4f932">(0000,1001)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5e2bf831-1bc3-4035-a13a-5688fddfc31c">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_771e7ba1-31bd-44b5-9361-261e06a503c6">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_258e847e-b930-44bb-a304-4c2dd7d8a62a">Contains the UID of the SOP Instance for which Attribute Values are to be modified.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_20c69a6b-ddcd-4ed0-94c7-42f853a6f00c">Modification List</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7de79c7b-c616-44d1-bae3-d7b055c79c4e">(no tag)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d88a075c-a467-493b-8b12-e1e7c22ca4c5">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_aea80f2d-a055-4915-8843-148f98ceb661">-</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_81eb7ef8-b594-45d5-97f2-1956ad0190d7">This field is encoded as a Data Set. One Data Element is encoded for each Attribute and Attribute Value applicable to the operation.</para>
      </td>
    </tr>
    </tbody>
  </table>
  <note>
    <para xml:id="para_33f68a73-7f80-4b62-916e-d0057df5dc70">The permitted contents of Modification List, encoded as a series of Data Elements, are defined in the Information Object Definition (<olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>) and Service Class Specifications (<olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>).</para>
  </note>
  </section>
<section label="10.3.3.2" status="4" xml:id="sect_10.3.3.2">
    <title>N-SET-RSP</title>
  
  <para xml:id="para_3cbf1b3e-21bb-4582-9af9-e067a5377868">The N-SET-RSP Message contains all fields as defined in <xref linkend="table_10.3-6" xrefstyle="select: label"/> and in <xref linkend="chapter_C" xrefstyle="template:Annex %n"/>. Each field shall conform to DICOM encoding and Value Representation as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>. Fields are required as specified in the N-SET service definition unless otherwise noted. Fields not specified in the N-SET service definition but present in <xref linkend="table_10.3-6" xrefstyle="select: label"/> are required by the DIMSE-N protocol.</para>
    <table frame="box" label="10.3-6" rules="all" xml:id="table_10.3-6">
    <caption>N-SET-RSP Message Fields</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_78da1291-2405-4997-b64e-ba4dbc1e4c80">
          <emphasis role="bold">Message Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_9c796b7c-91b9-40f8-900e-a93725041590">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_a4c10dd8-11f7-411a-8aaf-748521fb42a0">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_41411f45-ebb2-4061-a25a-708738533225">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_acfd8e2e-cc0e-4a23-b577-3e46634d8d3e">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_fa933fc0-4fe4-4b77-90cf-01cbad65dc79">Command Group Length</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_86b19a50-0a87-49ed-a516-8f479969c29b">(0000,0000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a9b35cc8-5eb9-4a41-8257-03cf9cb996da">UL</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_05c68dd7-7b40-4bc0-9736-4186051580be">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e54cd195-3567-49e0-9ff9-a3e4f67da3e8">The even number of bytes from the end of the value field to the beginning of the next group.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_603a36f3-92f2-4004-95b3-8947f8fdfa2d">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_800328bd-bf7f-43e2-b39d-7b4b15d87b29">(0000,0002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2ba9a954-b069-46e6-931b-9e63994a81c9">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_be20e100-4091-466c-a30a-fa4803f48b7c">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d965bfa5-870d-4afa-9ed7-3e9fe8fed382">SOP Class UID of the SOP Instance for which Attribute Values were modified.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d6122d05-cefa-4575-8ad0-e205114409f0">Command Field</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2eff9368-d7bc-4df2-a963-6e45a979a9d5">(0000,0100)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7d0976bc-b510-4476-b7f6-574435d9f728">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_39f6d09f-3aa4-48da-bf38-27931f53fb93">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_aadbcbc7-7520-4e92-8850-a2b116c1bddb">This field distinguishes the DIMSE-N operation conveyed by this Message. The value of this field shall be set to 8120H for the N-SET-RSP Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_115e3a97-3075-47a3-a88a-5ee156e82442">Message ID Being Responded To</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_79a73ef2-dec4-464a-a929-b88de041d98e">(0000,0120)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5da58d7e-6be5-4594-bda8-9a8f5c75120e">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_951d11f1-cc27-403a-892e-aaa73b43e6c0">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_fb68b01d-cc81-45f7-8050-19548fdfacf3">Shall be set to the value of the Message ID (0000,0110) field used in associated N-SET-RQ Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_8fd9ccbb-bf47-491e-96b8-4fd77347caa1">Command Data Set Type</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0b73ccc6-87dd-4278-a031-0de06e3b6d2c">(0000,0800)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b60bedcc-6a6a-42b4-9dad-3ce33c7f187b">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_12c0fbf3-903a-4f6c-b293-df101462eb29">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_fdeac7e4-570f-48b0-bea3-adad5aeea161">This field indicates if a Data Set is present in the Message. This field shall be set to the value of 0101H if no Data Set is present; any other value indicates a Data Set is included in the Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_64891977-fd01-4234-acaa-ff54f77e8a91">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a3660d4e-c213-4939-9dfa-71a474b78c13">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_04fabde3-9e78-4636-a8fb-cd523e22d802">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d9e34883-aec3-47d5-89c1-fd556e7b1ed6">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b0cd8034-3f40-4cb3-916f-fd346809a2be">The value of this field depends upon the status type. <xref linkend="chapter_C" xrefstyle="template:Annex %n"/> defines the encoding of the status types defined in the service definition.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_148e2e2b-42e9-4d8a-b787-afb7dc5a9e82">Affected SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_461494cd-35c1-463f-95f6-07509e258006">(0000,1000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_3b65ac74-801d-433d-977d-3026e0fe32b2">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b9eca593-afb8-460e-b943-e20b9b27dbab">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0e7abb80-6194-48f2-a414-73ac0d395968">Contains the UID of the SOP Instance for which Attribute Values were modified.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_96b08da5-0c96-4d31-8650-0113455d6c0a">Attribute List</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a70747a5-6ead-4e6b-880c-474f322c8609">(no tag)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_82721de9-b26f-42ba-aaf9-d70d997c9708">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_141c8692-d19a-4781-8820-072516d713ea">-</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1354eeda-2c51-4e3b-9ed3-f8265f11fc10">This field is encoded as a Data Set. One Data Element is encoded for each Attribute and Attribute Value applicable to the operation.</para>
      </td>
    </tr>
    </tbody>
  </table>
  <note>
    <para xml:id="para_ce326ef2-97c2-45e1-bcf7-4e92a298f48a">The permitted contents of Attribute List, encoded as a series of Data Elements, are defined in the Information Object Definition (<olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>) and Service Class Specifications (<olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>).</para>
  </note>
  </section>
<section label="10.3.3.3" status="4" xml:id="sect_10.3.3.3">
    <title>N-SET Protocol Procedures</title>
  
  <para xml:id="para_89e065c3-8438-486c-8934-6413c3aa2c1b">The N-SET procedures are initiated by the Invoking DIMSE Service User issuing an N-SET Request primitive. On receipt of the N-SET Request primitive the DIMSE-N protocol machine shall:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_f1319e80-6c3a-426e-88b2-56dc1bb1269c">construct a Message conveying the N-SET-RQ</para>
</listitem>
  <listitem>
<para xml:id="para_8a8da807-c2cf-4136-9c0e-155305c5cc44">send the Message using the P-DATA request service (see 8.1)</para>
</listitem>
</itemizedlist>
  <para xml:id="para_afeb8d38-de77-4fe3-874c-0bd1336633b7">On receipt of a Message conveying an N-SET-RQ the DIMSE-N protocol machine shall issue an N-SET indication primitive to the Performing DIMSE Service User.</para>
  <para xml:id="para_19dd1fbf-ce23-46c9-b6dc-cd77caefc9c9">On receipt of the N-SET response primitive, issued by the Performing DIMSE Service User, the DIMSE-N protocol machine shall:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_b7e9d41c-623b-4eb9-8064-afb26668e244">construct a Message conveying the N-SET-RSP</para>
</listitem>
  <listitem>
<para xml:id="para_d666494d-b3e6-48ee-be5b-b00583461a9c">send the Message using the P-DATA request service (see 8.1)</para>
</listitem>
</itemizedlist>
  <para xml:id="para_1b7e584d-58d9-44b7-b6ce-79dcaf22dff8">On receipt of a Message conveying an N-SET-RSP the DIMSE-N protocol machine shall issue an N-SET confirmation primitive to the Invoking DIMSE Service User, thus completing the N-SET procedure.</para>
  <para xml:id="para_6c0fa8e4-50e7-4f75-a96e-3b879632eaa7">The Performing DIMSE Service User may return an N-SET-RSP with the status of Failed or Refused before the complete N-SET-RQ request Message has been completely transmitted by the Invoking DIMSE Service User (this is called an early failed response). Upon receipt of this Failed or Refused N-SET-RSP the Invoking DIMSE Service User may terminate the Message before it is completely sent (i.e., set the Last Fragment bit to 1 in a Data PDV for this Message, see <xref linkend="chapter_F" xrefstyle="template:Annex %n"/>). Following this, it may invoke another operation or notification. It is a protocol violation for an Invoking DIMSE Service User to set the Last Fragment bit to 1 before an N-SET-RQ Message has been completely transmitted if it has not received a Failed or Refused N-SET-RSP to that request.</para>
  <note>
    <para xml:id="para_85715800-6878-431a-8d50-dd099cb70c64">When an Association is operating in asynchronous mode, it is possible for an Invoking DIMSE Service User to transmit several Messages before a response. Therefore, while sending a Message it may receive a response to a previously transmitted Message. In this case this response is not an early failed response because the related Message has already been sent.</para>
  </note>
  </section>
</section>
<section label="10.3.4" status="3" xml:id="sect_10.3.4">
    <title>N-ACTION Protocol</title>
  
    <para xml:id="para_ebfb6c5d-2133-4916-9ed3-ba275530b34b">The information necessary for the N-ACTION Request and N-ACTION Indication DIMSE-N primitives are conveyed in the N-ACTION-RQ Message. The information necessary for the N-ACTION response and confirmation DIMSE-N primitives are conveyed in the N-ACTION-RSP Message.</para>
  <section label="10.3.4.1" status="4" xml:id="sect_10.3.4.1">
    <title>N-ACTION-RQ</title>
  
  <para xml:id="para_d506a0f8-9b80-4102-b523-dca259e1280f">The N-ACTION-RQ Message contains fields as defined in <xref linkend="table_10.3-7" xrefstyle="select: label"/>. Each field shall conform to DICOM encoding and Value Representation as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>. Fields are required as specified in the N-ACTION service definition unless otherwise noted in <xref linkend="table_10.3-7" xrefstyle="select: label"/>. Fields not specified in the N-ACTION service definition but present in <xref linkend="table_10.3-7" xrefstyle="select: label"/> are required by the DIMSE-N protocol.</para>
    <table frame="box" label="10.3-7" rules="all" xml:id="table_10.3-7">
    <caption>N-ACTION-RQ Message Fields</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_d4febc47-817d-4915-ab02-1ebf94f0d235">
          <emphasis role="bold">Message Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_521a4880-86fc-43d8-a6de-1670134fff14">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_66de1cef-f356-45e3-b77b-b8d4d6f29509">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_3857d7ff-cfa5-4f35-8099-d9c77229f0d9">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_52a74d4b-9775-4a76-b8b3-b2e6acc42a64">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3423c789-5bdd-4e70-9d7b-c4f8c4d2378c">Command Group Length</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8400a7d6-eb62-42dd-ade6-f4767297e93a">(0000,0000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_873ac9ed-c383-4126-938a-aaeebf919923">UL</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_71c084d2-3794-4ef8-9d15-7a3199163f9c">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1962e12d-1d3e-4287-b81c-2fe584fb7c9d">The even number of bytes from the end of the value field to the beginning of the next group.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_dee0e5c1-0c96-4051-b2d6-962e8d117bfa">Requested SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_448a5c32-23c4-41a7-9465-4cdbb54b5c84">(0000,0003)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_80f3631a-afe2-45aa-9e69-b67add4161da">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_42238f2b-df8d-4d2a-ad47-45495ae85824">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6be1cd25-aaed-41cd-aa1b-d23210ba5d89">SOP Class UID of the SOP Instance for which the action is to be performed.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c21d7a9c-0c26-4153-8449-25df146ce086">Command Field</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1898de7b-acfa-4997-9559-d911c3096ddb">(0000,0100)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_693caf48-14b4-4ae2-b059-2c4cfd8dcdf2">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f2427e0f-c31c-4a67-9c49-c07bd455a8f7">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_ee2127c8-fd1a-40eb-867d-7d6a5d65e4f1">This field distinguishes the DIMSE-N operation conveyed by this Message. The value of this field shall be set to 0130H for the N-ACTION-RQ Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a4a3f6e1-5a8d-411c-8b79-2839a7fa1540">Message ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e12317d6-c91a-4a78-96f6-465dc691fad3">(0000,0110)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_884135fc-60bf-4e4f-86a0-8976c7e0447f">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_64fc2b11-7767-4578-bd4a-262704ee9d5d">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d9281508-fdea-458a-b9cd-d6e86b0b82f1">Implementation-specific value that distinguishes this Message from other Messages.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_638583d9-c102-4091-9502-b0a629717659">Command Data Set Type</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_66faab7a-7fe9-4b9d-bc26-c5a2ad8538b0">(0000,0800)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5849b062-e394-4354-894c-9e8ddfc0f856">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_cda93cae-f9f2-4a08-853e-8ec48af54a9c">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6677a2d4-c47c-4076-859f-736454ada5ca">This field indicates if a Data Set is present in the Message. This field shall be set to the value of 0101H if no Data Set is present; any other value indicates a Data Set is included in the Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1c37ea65-3415-41b2-ab66-4f1102a4c8b8">Requested SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ff527c2a-330c-4598-b610-bd24695efc10">(0000,1001)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_877c8e11-513a-44d8-a38a-ec330f54a4fe">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_419fafe2-781e-47dc-a23a-d9cba902d404">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0665730d-dac4-49a0-8125-1ce7e0dcc755">Contains the UID of the SOP Instance for which the action is to be performed.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_66311776-f48d-488c-b96c-ce6b15e8210e">Action Type ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f2adef1b-6135-46d0-ae75-d91eebdc1bd0">(0000,1008)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_19d8f83a-986d-4aea-b1ea-702dc35e4ee5">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ee428b2c-c056-427f-86bb-08efed27bb29">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_88c57560-ba34-406d-ad12-97df30b01567">Values for this field are application-specific.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0c00db0a-d26c-47a6-a0b4-d5d798a97a99">Action Information</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_00c405af-3052-4b76-8b5b-dd22e20ab666">(no tag)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9f92d912-b764-42b3-b42e-b93c5f7058d4">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1745be42-0a66-46fd-92a4-acb52ddaa1ab">-</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_28f1fc95-b8c3-405c-9968-00dc1c39696b">Application-specific Data Set containing additional information related to the operation.</para>
      </td>
    </tr>
    </tbody>
  </table>
  <note>
    <orderedlist numeration="arabic">
      <listitem>
        <para xml:id="para_bd3dc944-f959-446f-b33f-b2de105ff6c8">Service Class Specifications contained in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/> define the values needed for the Action Type ID (0000,1008) parameter.</para>
      </listitem>
      <listitem>
        <para xml:id="para_b692d503-5393-4d7c-bdd3-5d5dc81503b4">Service Class Specifications contained in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/> define the Data Set needed for the Action Information parameter.</para>
      </listitem>
    </orderedlist>
  </note>
  </section>
<section label="10.3.4.2" status="4" xml:id="sect_10.3.4.2">
    <title>N-ACTION-RSP</title>
  
  <para xml:id="para_b305230d-738a-489f-b912-bafc58455ca7">The N-ACTION-RSP Message contains fields as defined in <xref linkend="table_10.3-8" xrefstyle="select: label"/> and <xref linkend="chapter_C" xrefstyle="template:Annex %n"/>. Each field shall conform to DICOM encoding and Value Representation as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>. Fields are required as specified in the N-ACTION service definition unless otherwise noted in <xref linkend="table_10.3-8" xrefstyle="select: label"/>. Fields not specified in the N-ACTION service definition but present in <xref linkend="table_10.3-8" xrefstyle="select: label"/> are required by the DIMSE-N protocol.</para>
    <table frame="box" label="10.3-8" rules="all" xml:id="table_10.3-8">
    <caption>N-ACTION-RSP Message Fields</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_52cab110-cb8c-4116-b7fa-6bcc7f755ac9">
          <emphasis role="bold">Message Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_c68486dc-7cc7-4152-88fc-26d83723d25a">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_089be7d9-dc67-4b1b-87ee-ca5b6fdb4146">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_6c67ef7d-e27b-4aa2-89c8-0384a23a6073">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_033262db-1015-4288-86ab-6ec57f93686a">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d53e023d-eebe-481f-a13b-2a9b8e1db30f">Command Group Length</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6dd561cf-df98-45e6-840a-d16ec01f1f7c">(0000,0000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_98bca3a2-e5cf-49d9-9c2c-49a0dedf4620">UL</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a06789a6-d49d-471a-97d5-3902d8393562">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a6b6f502-2307-48df-be32-c2630148cd38">The even number of bytes from the end of the value field to the beginning of the next group.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d0430987-f221-4c83-b3ed-0a24ef3de3b1">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7b28235e-46b4-4568-b923-0cba5951a481">(0000,0002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4a3e71eb-fe7b-431f-8b96-9a50364fe3e4">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_bbdb659a-89a8-4b7d-b806-d49a22ee640e">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d7f5d3df-9932-4abc-b966-2335d03ab82c">SOP Class UID of the SOP Instance for which the action was performed.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5887dd5c-a0bd-47c2-a3eb-24be37cab165">Command Field</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f2f72235-9099-46a2-99ee-48772de3dfea">(0000,0100)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a22c25d9-166d-4729-9e57-6ebcb86dad5d">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8021b0c8-13b4-4f88-8173-53178976fb57">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f38364a3-ced4-4ade-983e-10425c0806ea">This field distinguishes the DIMSE-N operation conveyed by this Message. The value of this field shall be set to 8130H for the N-ACTION-RSP Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_21585073-8603-444c-b05f-8709d1ea448f">Message ID Being Responded To</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ccfdd296-a5b3-4a79-9685-f8ad89101e60">(0000,0120)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1da4a257-5056-4edd-8e73-b1c143c85356">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_076dcf4e-51cc-47bb-a5a2-9dcab2983822">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_df01d958-b286-497f-bfb7-a849330eb307">Shall be set to the value of the Message ID (0000,0110) field used in associated N-ACTION-RQ Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d1ef6408-7b2d-401e-a79d-4b6c2dbf84a3">Command Data Set Type</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5a6e6104-f8f8-481a-b934-26a2310c1d08">(0000,0800)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b934e33c-1207-48ba-a681-ef2d1ddfd2f5">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c3171580-8edb-4558-a8cd-50f032b9e188">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e387c9d5-f0da-4e8f-b214-b613b041112e">This field indicates if a Data Set is present in the Message. This field shall be set to the value of 0101H if no Data Set is present; any other value indicates a Data Set is included in the Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_be9e7e37-926f-4af6-950c-8cc262be0ac4">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d37ec1b7-ea83-494d-88e1-c2833235ae7b">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f6ff3a50-0c12-4d30-949f-ce3d678e6c11">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_441f194c-44a6-404a-970f-fe8166681685">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_bd3835fd-503d-4b1d-ae03-aa3ff4fff11d">The value of this field depends upon the status type. <xref linkend="chapter_C" xrefstyle="template:Annex %n"/> defines the encoding of the status types defined in the service definition.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_04f6820c-82d0-407e-ad5c-69ca23d1ee91">Affected SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_aa22a30a-a8a3-4c3e-9f9b-186c4cbb13b8">(0000,1000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_26ec26df-06e1-4562-9d38-776efe9a141a">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8d0f9fab-4b99-4f86-883f-4dad97fdd011">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_803f1039-7f91-4144-8897-ee5a0a5fd6fa">Contains the UID of the SOP Instance for which the action was performed.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_50300d75-0b41-43c5-a0b7-a2c32dca41ba">Action Type ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9e1bb940-b3ff-4a0f-b6cc-5a79c5065773">(0000,1008)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b3bfb05f-1bba-4ed6-bac1-ea80795117a8">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6040cd06-90c1-4736-965e-35b5380d48c2">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_530bb546-a70e-4448-99f9-70f1aae47066">Values for this field are application-specific.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_fd70c84e-2b3d-43d9-8204-4ae411e0988e">Action Reply</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a554d1ec-92ad-49da-b4df-1b82c3f805c5">(no tag)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_46d6f9b7-e71c-4866-8f66-f2a04a5a26c3">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_004781d6-6645-48b8-89a2-bf446e9589d9">-</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6e42c6fd-f7d2-43f0-b61c-ad9fb2827155">Application-specific Data Set containing additional information related to the operation.</para>
      </td>
    </tr>
    </tbody>
  </table>
  <note>
    <orderedlist numeration="arabic">
      <listitem>
        <para xml:id="para_f2936a3c-c92e-4c45-8a56-2ee9dea7b62d">Service Class Specifications contained in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/> define the values needed for the Action Type ID (0000,1008) parameter.</para>
      </listitem>
      <listitem>
        <para xml:id="para_8fc5896b-f65b-4360-bb52-8edc89ab3e29">Service Class Specifications contained in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/> define the Data Set needed for the Action Reply parameter related to each defined Action Type ID.</para>
      </listitem>
      <listitem>
        <para xml:id="para_54f5685f-4a50-4797-ae39-280b76405604">Service Class Specifications contained in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/> define the encoding of the Action Reply parameter.</para>
      </listitem>
    </orderedlist>
  </note>
  </section>
<section label="10.3.4.3" status="4" xml:id="sect_10.3.4.3">
    <title>N-ACTION Protocol Procedures</title>
  
  <para xml:id="para_c77c36f1-f07c-4063-b1c6-473a56bf1dbd">The N-ACTION procedures are initiated by the Invoking DIMSE Service User issuing an N-ACTION Request primitive. On receipt of the N-ACTION Request primitive the DIMSE-N protocol machine shall:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_ba10f1a7-9e84-4847-8609-4b7cefc93858">construct a Message conveying the N-ACTION-RQ</para>
</listitem>
  <listitem>
<para xml:id="para_6c93691e-b49b-4b38-9e4a-22a78e4b66e6">send the Message using the P-DATA request service (see 8.1)</para>
</listitem>
</itemizedlist>
  <para xml:id="para_a565c4b6-6652-425e-ad98-f06d14fb9803">On receipt of a Message conveying an N-ACTION-RQ the DIMSE-N protocol machine shall issue an N-ACTION indication primitive to the Performing DIMSE Service User.</para>
  <para xml:id="para_15bfb024-5253-406b-ac62-400e132fdfa3">On receipt of the N-ACTION response primitive, issued by the Performing DIMSE Service User, the DIMSE-N protocol machine shall:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_3e098a2f-a88b-4837-aedc-c6939543276a">construct a Message conveying the N-ACTION-RSP</para>
</listitem>
  <listitem>
<para xml:id="para_440623fa-c4ab-44c6-8bf9-490a9178dd18">send the Message using the P-DATA request service (see 8.1)</para>
</listitem>
</itemizedlist>
  <para xml:id="para_c0a6b4d0-3b98-454b-bba2-e68d42a22598">On receipt of a Message conveying an N-ACTION-RSP the DIMSE-N protocol machine shall issue an N-ACTION confirmation primitive to the Invoking DIMSE Service User, thus completing the N-ACTION procedure.</para>
  <para xml:id="para_e861a433-f7c1-4e36-9ee3-0a3aa3621a41">The Performing DIMSE Service User may return an N-ACTION-RSP with the status of Failed or Refused before the complete N-ACTION-RQ request Message has been completely transmitted by the Invoking DIMSE Service User (this is called an early failed response). Upon receipt of this Failed or Refused N-ACTION-RSP the Invoking DIMSE Service User may terminate the Message before it is completely sent (i.e., set the Last Fragment bit to 1 in a Data PDV for this Message, see <xref linkend="chapter_F" xrefstyle="template:Annex %n"/>). Following this, it may invoke another operation or notification. It is a protocol violation for an Invoking DIMSE Service User to set the Last Fragment bit to 1 before an N-ACTION-RQ Message has been completely transmitted if it has not received a Failed or Refused N-ACTION-RSP to that request.</para>
  <note>
    <para xml:id="para_f8f60263-ecce-429a-a0f9-afdbdbe2c7bc">When an Association is operating in asynchronous mode, it is possible for an Invoking DIMSE Service User to transmit several Messages before a response. Therefore, while sending a Message it may receive a response to a previously transmitted Message. In this case this response is not an early failed response because the related Message has already been sent.</para>
  </note>
  </section>
</section>
<section label="10.3.5" status="3" xml:id="sect_10.3.5">
    <title>N-CREATE Protocol</title>
  
    <para xml:id="para_9044885f-97f4-4f8a-a92d-f4164eb74c17">The information necessary for the N-CREATE Request and -CREATE Indication DIMSE-N primitives are conveyed in the N-CREATE-RQ Message. The information necessary for the N-CREATE response and confirmation DIMSE-N primitives are conveyed in the N-CREATE-RSP Message.</para>
  <section label="10.3.5.1" status="4" xml:id="sect_10.3.5.1">
    <title>N-CREATE-RQ</title>
  
  <para xml:id="para_4e8ea3d4-192a-41e2-bf9d-07d39d155c79">The N-CREATE-RQ Message contains fields as defined in <xref linkend="table_10.3-9" xrefstyle="select: label"/>. Each field shall conform to DICOM encoding and Value Representation as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>. Fields are required as specified in the N-CREATE service definition unless otherwise noted in <xref linkend="table_10.3-9" xrefstyle="select: label"/>. Fields not specified in the N-CREATE service definition but present in <xref linkend="table_10.3-9" xrefstyle="select: label"/> are required by the DIMSE-N protocol.</para>
    <table frame="box" label="10.3-9" rules="all" xml:id="table_10.3-9">
    <caption>N-CREATE-RQ Message Fields</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_4c89b451-19a0-4304-88ac-8df3d4849cc8">
          <emphasis role="bold">Message Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_9bf34b55-3174-4e32-8c33-ffd599ea5578">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_6ff8c523-b59e-4db3-8e69-44bc42f35c5b">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_5cf7e6b4-04ba-44c8-b952-a8dbb1c948b6">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_7d75c87d-f10d-430b-a276-0f5bb372b153">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_2539db62-1cc3-426c-a147-b8305f8d91cf">Command Group Length</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f298072f-7e26-465e-8aa2-dd1403056630">(0000,0000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f897a569-7ebd-4d46-a2ba-30a4d13a7560">UL</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ab27463d-49ad-4fc4-94a7-55e383141f19">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d8ef048d-c5b5-4c17-8742-b0b5d1046bbf">The even number of bytes from the end of the value field to the beginning of the next group.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_da28b6c6-e375-4190-a2e7-7236d77e717b">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7995fbf7-999d-4538-a914-507a872d0213">(0000,0002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ac64617a-16de-42d3-9ee0-9eba752eb474">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c1f8d873-ed54-475c-a35f-c0619dd129e1">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_4da7ac0e-e3b1-4ea5-9574-6ebf3f5119bb">SOP Class UID of the SOP Instance to be created.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f08eed45-ad0e-47e2-a188-e7ea3aa7a990">Command Field</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e7072998-d21d-43a9-a39e-b0784b2222f8">(0000,0100)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_61ad58f9-4d36-4896-a5bb-5ca124362290">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e3734115-3548-47a6-b2ee-281b88490ef0">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5065dbb6-d9dd-41d6-a6b5-49802ebdcdf4">This field distinguishes the DIMSE-N operation conveyed by this Message. The value of this field shall be set to 0140H for the N-CREATE-RQ Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5fb0a3cb-a1ca-498c-8981-a042f10def53">Message ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_85504b68-676e-4304-9d28-e5300fda3655">(0000,0110)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_cd7147db-c2aa-4d3d-af2c-56c61533f70c">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_60c5932c-5540-46a2-a8de-0a932722c613">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_24ae4d46-c793-441b-a8d2-0315d9c5f97a">Implementation-specific value that distinguishes this Message from other Messages.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_19db0cfe-b0ea-4985-afb3-447b0fec9e77">Command Data Set Type</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_30538e0a-240f-4f2b-82ef-4206f9817d44">(0000,0800)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_76929a2f-9963-473a-8ad2-17eb7b92a03f">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7a6864a0-e302-4cf9-ac2f-adc4408d6c4f">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a64f5d8e-d21a-46bd-96ea-6f073ad73fcf">This field indicates that if a Data Set is present in the Message. This field shall be set to the value of 0101H if no Data Set is present; any other value indicates a Data Set is included in the Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_70047d97-9057-41c8-890c-447cc5552492">Affected SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5417ba18-5a4d-4dba-9300-d62da2e9a33b">(0000,1000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_cb10a9b0-255d-4615-9cbc-5702036dfb69">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_bde0eb1a-9d46-4ba3-8d54-2cf599d04017">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e84238d5-ae21-4338-a69c-89668ee88de8">Contains the UID of the SOP Instance to be created.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_8d017045-1f36-4e20-aadf-d8fcdb58e766">Attribute List</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_69c5a73f-c03c-4a80-85f5-ab447dd929c7">(no tag)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9d03ce24-647a-42b1-9275-158b0f42d69e">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7f7c7a0d-679b-46cb-9e1e-3a2fef9d61e4">-</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_200a873e-d0be-4de4-ac11-b183685e6077">This field is encoded as a Data Set. One Data Element is encoded for each Attribute and Attribute Value applicable to the operation.</para>
      </td>
    </tr>
    </tbody>
  </table>
  <note>
    <para xml:id="para_78098816-8094-4713-82f0-bd354d992268">The permitted contents of Attribute List, encoded as a series of Data Elements, are defined in the Information Object Definition (<olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>) and Service Class Specifications (<olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>).</para>
  </note>
  </section>
<section label="10.3.5.2" status="4" xml:id="sect_10.3.5.2">
    <title>N-CREATE-RSP</title>
  
  <para xml:id="para_f61dd6ba-aa21-4400-a29a-ec1a03c29264">The N-CREATE-RSP Message contains fields as defined in <xref linkend="table_10.3-10" xrefstyle="select: label"/> and <xref linkend="chapter_C" xrefstyle="template:Annex %n"/>. Each field shall conform to DICOM encoding and Value Representation as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>. Fields are required as specified in the N-CREATE service definition unless otherwise noted in Table10.3-10. Fields not specified in the N-CREATE service definition but present in <xref linkend="table_10.3-10" xrefstyle="select: label"/> are required by the DIMSE-N protocol.</para>
    <table frame="box" label="10.3-10" rules="all" xml:id="table_10.3-10">
    <caption>N-CREATE-RSP Message Fields</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_b2d34340-7c8c-4d3f-8484-f5a552e74358">
          <emphasis role="bold">Message Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_3c2862ad-ec3b-4109-bb0a-c92f838ffafc">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_1ebcb352-648a-430e-97cc-6e2c9ff0538a">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_721e2a35-72a4-4b67-8f41-b250e61e1443">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_664e2c80-a86c-4591-aa0a-d4a46e636ac3">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6676140d-6921-4169-b11f-9210e7087a15">Command Group Length</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_dd7e236f-e0d3-40bc-b2ee-4332756b456f">(0000,0000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c254f330-5a73-4aac-8545-bc0e2c844eb4">UL</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f8070fed-56fc-4a67-87a2-e764a3136eb8">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_afe9adb3-465a-47f6-8071-44072a62dad3">The even number of bytes from the end of the value field to the beginning of the next group.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b7b77825-4236-45d2-972d-044498f22e78">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_958cdf13-4cd5-4017-b953-645c87a4a1dc">(0000,0002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_aee4fb41-8811-4f49-8afd-13e950775122">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_70834ba8-7cf9-48bc-a9b2-3b06944ee14f">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_55c92f11-964a-46bf-8602-14e758dd28a5">SOP Class UID of the SOP Instance that was created.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c508576e-28ec-45b3-bb90-c9559a05aea1">Command Field</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d5c8ea68-a976-42fb-be52-4324f7122301">(0000,0100)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c8d14e63-aabb-4ed7-ad9f-385d6d222ae0">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9f153353-61c5-4100-a7c5-6e9f9f47036e">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d4e58154-ae07-4b1e-a18e-917a89087a3f">This field distinguishes the DIMSE-N operation conveyed by this Message. The value of this field shall be set to 8140H for the N-CREATE-RSP Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_53b7f759-462c-45fb-8d81-dcddbaf5f982">Message ID Being Responded To</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4819bda1-002b-4801-a6ba-6a0022749f58">(0000,0120)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_cf690db5-978c-4abf-8438-b4342b2e332a">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_05a4f409-99ce-49de-9267-d6be9719751f">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_2fcbaff9-1958-439d-ade4-523dc8dd1a01">Shall be set to the value of the Message ID (0000,0110) field used in associated N-CREATE-RQ Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a6f9317c-6944-4052-9a9e-eb3933426f6e">Command Data Set Type</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c6a2ee10-0a6d-44af-9dda-4452172311d3">(0000,0800)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9ca33be1-4462-4479-9721-0b377b4b8957">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_65a2adcd-c207-47ac-847e-5f0b3da7d09f">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1900ab0d-6286-4306-b122-bc79f6189345">This field indicates if a Data Set is present in the Message. This field shall be set to the value of 0101H if no Data Set is present; any other value indicates a Data Set is included in the Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_8f842cb8-3cdd-4538-adc0-fc10637c06e2">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ceee7a07-6ca6-4e67-94f8-4aebedf2a4e7">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_cfa46154-64f3-491b-a0af-889c9b577be6">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d0d51aad-c63b-4304-8e5d-31e179b89e8d">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6bd816d6-82ee-415d-a7cc-762c189774d4">The value of this field depends upon the status type. <xref linkend="chapter_C" xrefstyle="template:Annex %n"/> defines the encoding of the status types defined in the service definition.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_96d1b40e-64d3-4c44-9525-24dcfa68d3b4">Affected SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5264c614-6cfd-4110-903e-cf1363737831">(0000,1000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_89b1471b-5b6c-4e86-a155-d7186f082593">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_327aa9b7-9ae0-4211-9018-b2658f9e8eb2">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_287f4423-c939-41ea-a38d-da1f22cae79f">Contains the UID of the SOP Instance that was created.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5dfef6f6-f352-416f-92a6-3982864b2eb3">Attribute List</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b75520ad-fd24-47ee-b7b2-18faab885b5a">(no tag)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_12280639-491b-420e-8119-0391f9bcbe34">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f4b9377f-aa0b-403b-8e69-b31a8fdcd55e">-</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_abb5d72b-6d93-4c87-9453-08d397b179e3">This field is encoded as a Data Set. One Data Element is encoded for each Attribute and Attribute Value applicable to the operation.</para>
      </td>
    </tr>
    </tbody>
  </table>
  <note>
    <para xml:id="para_d1273667-4085-4a55-96e0-48cecd9522d0">The permitted contents of Attribute List, encoded as a series of Data Elements, are defined in the Information Object Definition (<olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>) and Service Class Specifications (<olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>).</para>
  </note>
  </section>
<section label="10.3.5.3" status="4" xml:id="sect_10.3.5.3">
    <title>N-CREATE Protocol Procedures</title>
  
  <para xml:id="para_2cd4ea57-7d66-4c5d-9441-a67ede641191">The N-CREATE procedures are initiated by the Invoking DIMSE Service User issuing an N-CREATE Request primitive. On receipt of the N-CREATE Request primitive the DIMSE-N protocol machine shall:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_ec970bd1-6572-47a8-8729-22e6904a0d1f">construct a Message conveying the N-CREATE-RQ</para>
</listitem>
  <listitem>
<para xml:id="para_739ea1dc-56fe-4594-a242-285df55f85dd">send the Message using the P-DATA request service (see 8.1)</para>
</listitem>
</itemizedlist>
  <para xml:id="para_61ee714a-bef1-413b-86dd-50a6353cf7bb">On receipt of a Message conveying an N-CREATE-RQ the DIMSE-N protocol machine shall issue an N-CREATE indication primitive to the Performing DIMSE Service User.</para>
  <para xml:id="para_7f3ef43b-05be-4382-8e23-40704e5f40e4">On receipt of the N-CREATE response primitive, issued by the Performing DIMSE Service User, the DIMSE-N protocol machine shall:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_4f1087ac-c747-4b14-9672-007b941f2aad">construct a Message conveying the N-CREATE-RSP</para>
</listitem>
  <listitem>
<para xml:id="para_93a6f802-2e5a-4b68-ac58-ee09e4111755">send the Message using the P-DATA request service (see 8.1)</para>
</listitem>
</itemizedlist>
  <para xml:id="para_5973c9f7-7ddf-4edf-933b-7c018342ab73">On receipt of a Message conveying an N-CREATE-RSP the DIMSE-N protocol machine shall issue an N-CREATE confirmation primitive to the Invoking DIMSE Service User, thus completing the N-CREATE procedure.</para>
  <para xml:id="para_5f9e9d51-bc3c-4961-8185-ff194cb2c28f">The Performing DIMSE Service User may return an N-CREATE-RSP with the status of Failed or Refused before the complete N-CREATE-RQ request Message has been completely transmitted by the Invoking DIMSE Service User (this is called an early failed response). Upon receipt of this Failed or Refused N-CREATE-RSP the Invoking DIMSE Service User may terminate the Message before it is completely sent (i.e., set the Last Fragment bit to 1 in a Data PDV for this Message, see <xref linkend="chapter_F" xrefstyle="template:Annex %n"/>). Following this, it may invoke another operation or notification. It is a protocol violation for an Invoking DIMSE Service User to set the Last Fragment bit to 1 before an N-CREATE-RQ Message has been completely transmitted if it has not received a Failed or Refused N-CREATE-RSP to that request.</para>
  <note>
    <para xml:id="para_794c3336-508c-42ae-8f12-78acd25778ca">When an Association is operating in asynchronous mode, it is possible for an Invoking DIMSE Service User to transmit several Messages before a response. Therefore, while sending a Message it may receive a response to a previously transmitted Message. In this case this response is not an early failed response because the related Message has already been sent.</para>
  </note>
  </section>
</section>
<section label="10.3.6" status="3" xml:id="sect_10.3.6">
    <title>N-DELETE Protocol</title>
  
    <para xml:id="para_e5fa4be0-e11c-40be-acb6-181babd33391">The information necessary for the N-DELETE Request and N-DELETE Indication DIMSE-N primitives are conveyed in the N-DELETE-RQ Message. The information necessary for the N-DELETE response and confirmation DIMSE-N primitives are conveyed in the N-DELETE-RSP Message.</para>
  <section label="10.3.6.1" status="4" xml:id="sect_10.3.6.1">
    <title>N-DELETE-RQ</title>
  
  <para xml:id="para_e7831dd2-2d76-4e79-8240-d5b929161442">The N-DELETE-RQ Message contains fields as defined in <xref linkend="table_10.3-11" xrefstyle="select: label"/>. Each field shall conform to DICOM encoding and Value Representation as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>. Fields are required as specified in the N-DELETE service definition unless otherwise noted in <xref linkend="table_10.3-11" xrefstyle="select: label"/>. Fields not specified in the N-DELETE service definition but present in <xref linkend="table_10.3-11" xrefstyle="select: label"/> are required by the DIMSE-N protocol.</para>
    <table frame="box" label="10.3-11" rules="all" xml:id="table_10.3-11">
    <caption>N-DELETE-RQ Message Fields</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_969f6470-47da-4ec8-a0fb-d636b8bc3d2f">
          <emphasis role="bold">Message Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_332e025a-0e83-4e10-9813-8f24372627b7">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_bd11300d-14ff-41b2-b4d3-9c83ab5268f8">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_6c7339a4-dff5-4b5a-ae05-30e6b046f0cb">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_0ebd2bb5-61cf-41fb-bbd0-a6c8855c14c6">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_85eafdbe-3d0f-42a3-8b1a-306113835cda">Command Group Length</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4fb1048f-5553-4d8f-a8b2-536ab1c86feb">(0000,0000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_959a6ad9-189f-4aa2-b2ef-827e07737700">UL</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1b81a29e-c4aa-4517-bf7e-814643eb5799">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c727b9fe-7dbd-47a6-b9cc-ebb8f4d9954b">The even number of bytes from the end of the value field to the beginning of the next group.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_afd21ce8-c13e-442b-927d-7a92ed007cfd">Requested SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6475e172-1a32-457f-aa08-547ea5fd6d6e">(0000,0003)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_911c3bc4-a27e-45d6-b215-aae9b942b96b">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_fd6b306f-1eff-455c-8be9-da1f5fb76845">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f9d54d29-e371-4a2c-b570-ef36e40387e3">SOP Class UID of the SOP Instance to be deleted.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_2bc5f910-8d1b-4372-8d81-94b2352e004b">Command Field</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9734102b-e920-4b3f-baf5-7e1a69370bf5">(0000,0100)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_11d0e914-3141-43d6-b11c-8dac0afad30e">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d9ecfa91-75f8-4f31-9735-71fa2c777262">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1bd5ad13-acb2-417e-8619-b3416f5e9ea0">This field distinguishes the DIMSE-N operation conveyed by this Message. The value of this field shall be set to 0150H for the N-DELETE-RQ Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e6ae4b9f-0479-4e93-8263-c35b13da5bb4">Message ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6ce4fad2-f2b6-4fd4-a3e3-e33017f9da5f">(0000,0110)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_de6912ff-d537-46eb-8097-5545d2a10d68">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_961edcf6-2aa9-4f4f-9ee8-f62d74ffc9e6">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f7d13d27-bcec-4c9a-9ddb-67ba609fa4c3">Implementation-specific value that distinguishes this Message from other Messages.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d2d7cf2a-3e53-4bd3-82ec-e56587ffc0b8">Command Data Set Type</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8e33f927-8f3f-41de-be2a-76c4141c1024">(0000,0800)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_dd3b2ba8-f254-44bf-9901-679a9bfe4f68">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_732a120d-8f06-4e59-9373-5445de6465b9">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_cf42407f-520f-4eb5-8bea-86331667bc00">This field indicates that no Data Set is present in the Message. It shall be set to the value of 0101H.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_2af2ee0a-00b6-4a93-b56b-12699fa81281">Requested SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1035b056-ba6f-49a0-9a85-912b5eb03b63">(0000,1001)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_bc1ce911-0fab-496e-9d0e-9ca068c3cf17">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ab28715b-9078-44bc-93fc-16ce8ccbb882">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_245aff04-42bc-4d86-8ca7-b9dc0f8ada82">Contains the UID of the SOP Instance to be deleted.</para>
      </td>
    </tr>
    </tbody>
  </table>
  </section>
<section label="10.3.6.2" status="4" xml:id="sect_10.3.6.2">
    <title>N-DELETE-RSP</title>
  
  <para xml:id="para_0697bbbd-8d14-429b-89a2-65add7993766">The N-DELETE-RSP Message contains fields as defined in <xref linkend="table_10.3-12" xrefstyle="select: label"/> and <xref linkend="chapter_C" xrefstyle="template:Annex %n"/>. Each field shall conform to DICOM encoding and Value Representation as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>. Fields are required as specified in the N-DELETE service definition unless otherwise noted in <xref linkend="table_10.3-12" xrefstyle="select: label"/>. Fields not specified in the N-DELETE service definition but present in <xref linkend="table_10.3-12" xrefstyle="select: label"/> are required by the DIMSE-N protocol.</para>
    <table frame="box" label="10.3-12" rules="all" xml:id="table_10.3-12">
    <caption>N-DELETE-RSP Message Fields</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_af143cf9-1d04-4a0a-b716-5ebce76a847d">
          <emphasis role="bold">Message Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_45d0621a-0857-4918-a644-198f50fd70e8">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_998dfad8-6c41-4528-a9bc-af160527c65a">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_39b4b588-3c78-40dd-9205-d1776e0184c4">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_982622e2-0a6f-408d-9b34-993e6d2f2061">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_95c20a7a-a24e-4116-abcc-fdca26fb4964">Command Group Length</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a4773beb-ce56-4204-858b-09321da11434">(0000,0000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_85fda1b0-67ec-4228-8d3a-b279a9551205">UL</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_db7c3137-4f31-4193-92b7-f431dd482c66">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_658b1a70-2c45-40a8-b66f-aec0cce03ce9">The even number of bytes from the end of the value field to the beginning of the next group.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0b315c41-b046-4daa-bd0e-382cce6705db">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b2ae7ca8-6127-41e7-a858-01ad300a9474">(0000,0002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c4749f5f-6025-453b-ae98-acf1a79dfc95">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_653dd34b-5690-4060-af2a-787ec9352b61">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9bc8df64-b7e1-4a1c-9f30-f7b400f25568">SOP Class UID of the SOP Instance that was deleted.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_4e27b131-9140-43ec-ac2d-e01fe37ad753">Command Field</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1f2666b2-9e1f-4265-bc7c-646cff0aab64">(0000,0100)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b706f5bb-e804-4e79-b275-d51fb60c2b90">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_14a580f7-1cd8-4073-bfbd-c29c249213f1">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a383b9ce-8988-43b5-8f42-5b4636416464">This field distinguishes the DIMSE-N operation conveyed by this Message. The value of this field shall be set to 8150H for the N-DELETE-RSP Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3e31e689-a60e-4901-b49d-b80b30ecd319">Message ID Being Responded To</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_19f67af0-121c-4c06-8be4-dbdfb284a23b">(0000,0120)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_eebac39d-3dc6-4edc-b7b4-4dcbf84e4fce">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8c05a804-f50f-4821-b9a2-9042cdc29e74">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_4534abb9-4bb7-4e54-860e-7c209ffbcc4f">Shall be set to the value of the Message ID (0000,0110) field used in associated N-DELETE-RQ Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_92e522e2-01f7-428a-8562-e19bb232b6af">Command Data Set Type</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f53f390d-65a7-4e90-b178-2e872865b6af">(0000,0800)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_cb59ec66-d05c-44fa-8567-5f60cf5b65e5">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_daed31dd-0809-4f96-a461-c9c2bf0bdf20">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_dd951646-5521-4eb1-9fc8-40b5ad621e50">This field indicates that no Data Set is present in the Message. This field shall be set to the value of 0101H).</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_78c588f4-b8c2-4b3c-a31a-6ff5a919f0e0">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e8c86738-bb0d-4dcc-a0de-1fcfc51c7032">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_48f6fd25-bd7f-48af-b997-b29925823901">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5c31af56-81a3-40a9-be1c-5f7b0bb5b46d">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9653c78b-9977-4f0b-9ef0-8c5795c03a5d">The value of this field depends upon the status type. <xref linkend="chapter_C" xrefstyle="template:Annex %n"/> defines the encoding of the status types defined in the service definition.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_293475cd-e409-4920-86f8-8dc1b1dad135">Affected SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_aa216ce9-a1b4-42da-884d-4e9bfa0652c8">(0000,1000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_657fa36d-a5c1-4e3f-bcae-692330c9d2b2">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_843cd62b-1ee6-4886-8077-12240721aec6">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_fb54e084-ac71-4727-983f-3399be517bb4">Contains the UID of the SOP Instance that was deleted.</para>
      </td>
    </tr>
    </tbody>
  </table>
  </section>
<section label="10.3.6.3" status="4" xml:id="sect_10.3.6.3">
    <title>N-DELETE Protocol Procedures</title>
  
  <para xml:id="para_18a22519-4d5b-4653-8b6d-dc53f5287c7b">The N-DELETE procedures are initiated by the Invoking DIMSE Service User issuing an N-DELETE Request primitive. On receipt of the N-DELETE Request primitive the DIMSE-N protocol machine shall:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_21497005-a07c-4013-b2e4-6ea3720a5e0d">construct a Message conveying the N-DELETE-RQ</para>
</listitem>
  <listitem>
<para xml:id="para_c2c7a4d9-9f18-427f-a95c-c376b74aca13">end the Message using the P-DATA request service (see 8.1)</para>
</listitem>
</itemizedlist>
  <para xml:id="para_dcec5a9b-d863-428f-98e4-c76c0a2ecd24">On receipt of a Message conveying an N-DELETE-RQ the DIMSE-N protocol machine shall issue an N-DELETE indication primitive to the Performing DIMSE Service User.</para>
  <para xml:id="para_74e47a95-441f-475a-b78c-a251c53f95f0">On receipt of the N-DELETE response primitive, issued by the Performing DIMSE Service User, the DIMSE-N protocol machine shall:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_425971a2-345c-4cbe-9f6f-07d19ce98c49">construct a Message conveying the N-DELETE-RSP</para>
</listitem>
  <listitem>
<para xml:id="para_54a1096b-e6c1-4dd2-ac03-91bad35c4e0e">send the Message using the P-DATA request service (see 8.1)</para>
</listitem>
</itemizedlist>
  <para xml:id="para_43f26886-1d97-42a2-8099-8f9cf74cd3bb">On receipt of a Message conveying an N-DELETE-RSP the DIMSE-N protocol machine shall issue an N-DELETE confirmation primitive to the Invoking DIMSE Service User, thus completing the N-DELETE procedure.</para>
  
  </section>
</section>
</section>
</chapter>
<chapter label="A" status="1" xml:id="chapter_A">
    <title>Application Context Usage (Normative)</title>
  
  <section label="A.1" status="2" xml:id="sect_A.1">
    <title>Application Context Definition</title>
  
  <para xml:id="para_520d19a5-b440-4f5a-a397-73c0b93c8075">An Application Context explicitly defines the set of application service elements, related options and any other information necessary for the inter working of Application Entities on an Association; in particular, it specifies the DIMSE Protocol used by the Application Layer.</para>
  <para xml:id="para_d5d3f029-caf1-428a-babf-92108a0a7d9e">Two Application Entities establish an Association by agreeing on an Application Context. The requestor of an Association proposes an Application Context Name and the acceptor returns either the same or a different Application Context Name. The returned name specifies the Application Context to be used for this Association. The offer of an alternate Application Context by the acceptor provides a mechanism for limited negotiation. If the requestor cannot operate in the acceptor's Application Context, it shall issue an A-Abort Request primitive. Such a negotiation will facilitate the introduction of new versions of the DICOM Message Exchange Protocol in the future.</para>
  </section>
<section label="A.2" status="2" xml:id="sect_A.2">
    <title>DICOM Application Context Name Encoding and Registration</title>
  
  <para xml:id="para_ce277e09-c8dc-4d44-9ea6-adb1edd9a9ab">The Application Context Name structure is based on the OSI Object Identification (numeric form) as defined by ISO 8824. Specific rules are defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>. Application Context Names are registered values as defined by ISO 9834-1 to ensure global uniqueness. Application Context Names shall be encoded as defined in <olink targetdoc="PS3.8" targetptr="PS3.8" xrefstyle="select: labelnumber"/>.</para>
  <section label="A.2.1" status="3" xml:id="sect_A.2.1">
    <title>DICOM Registered Application Context Names</title>
  
  <para xml:id="para_0eaa7e46-94f8-4ff1-b63d-4291fe243402">The organization responsible for the definition and registration of DICOM Application Context Names is ACR-NEMA. ACR-NEMA guarantees uniqueness for all DICOM Application Context Names. A choice of DICOM registered Application Context Names related to a specific version of DIMSE, as well as the associated negotiation rules, are defined in this annex.</para>
  <para xml:id="para_a3748c44-9f37-4e14-888f-ae7bab18aa8a">A single DICOM Application Context Name is defined for this version of this Standard. This name is "1.2.840.10008.3.1.1.1"</para>
  </section>
<section label="A.2.2" status="3" xml:id="sect_A.2.2">
    <title>Privately Defined Application Context Names</title>
  
  <para xml:id="para_bb9d9d62-5d3e-4b94-8d2b-319306935dbd">Privately defined Application Context Names may also be used, but they will not be registered by ACR-NEMA. Organizations that define private Application Context Names are responsible to obtain their proper registration as defined for OSI Object Identifiers. National Standards Organizations representing a number of countries (e.g., UK, France, Germany, Japan, USA, etc.) to the International Standards Organization act as a registration authority as defined by ISO 9834-1.</para>
  <note>
    <para xml:id="para_248e36f5-b075-4b9b-af26-53f4b7eef2a0">For example, in the USA, ANSI assigns Organization Identifiers to any requesting organization. This identifier is made of a series of four numeric elements; 1 (identifies ISO), 2 (identifies the ISO member bodies branch), 840 (identifies ANSI as the ISO member body representing the USA), and xxxxxx (identifies a specific organization and is issued by ANSI). Such an identifier may be used by the identified organization as a root to which it may add a suffix made of one or more numeric elements. The identified organization accepts the responsibility to properly register these suffixes to ensure uniqueness.</para>
  </note>
  <para xml:id="para_f69b248c-f080-4377-b61e-19deb5a61d62">Privately defined Application Context Names shall be encoded as defined in <olink targetdoc="PS3.8" targetptr="PS3.8" xrefstyle="select: labelnumber"/>. The Organization identifier "1.2.840.10008" is reserved for DICOM and shall not be used for privately defined Application Context Names.</para>
  </section>
</section>
<section label="A.3" status="2" xml:id="sect_A.3">
    <title>Association Initialization for DICOM Application Entity</title>
  
  <para xml:id="para_69e24d1e-38c8-499b-a3fa-e5a01dfeef89">The establishment of an Association involves two DICOM AEs, one that is the Association-requestor and one that is the Association-acceptor.</para>
  <para xml:id="para_1bcfe078-d216-4a45-bcf0-99c953972d94">A DICOM AE shall initiate an Association establishment by using the A-ASSOCIATE request service defined in <olink targetdoc="PS3.8" targetptr="PS3.8" xrefstyle="select: labelnumber"/>. It shall provide the Application Association Information as defined by <xref linkend="chapter_D" xrefstyle="template:Annex %n"/>.</para>
  </section>
<section label="A.4" status="2" xml:id="sect_A.4">
    <title>Operation/Notification for DICOM Application Entity</title>
  
  <para xml:id="para_0363dba7-d41c-410a-918e-75baf0bd6702">Operations and notifications are only used on an Association. They result in Messages exchanged by using the P-DATA request service defined in <olink targetdoc="PS3.8" targetptr="PS3.8" xrefstyle="select: labelnumber"/>.</para>
  <para xml:id="para_28b47c00-0059-478f-937e-5189e6ea1fb6">All operations and notifications invoked over an Association shall be confirmed. The performing DICOM AE shall report the response of each operation or notification over the same Association by means of which the operation or notification was invoked. No recovery shall be performed using multiple Associations.</para>
  <para xml:id="para_e1c1bbaa-905c-46b2-8be7-fb4109d2f3cc">Operations and notifications, on an Association, shall use one of the following two modes:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_9e107bea-26b3-49fb-a168-be8673d73a76">synchronous, where the invoking DICOM AE, on a established Association, requires a response from the performing DICOM AE before invoking another operation or notification</para>
</listitem>
  <listitem>
<para xml:id="para_eccb0f0b-a33e-4b7e-954e-43860abce621">asynchronous, where the invoking DICOM AE, on a established Association, may continue to invoke further operations or notifications to the performing DICOM AE without awaiting a response</para>
</listitem>
</itemizedlist>
  <note>
    <para xml:id="para_1beb8451-b7c5-49e1-a785-2d974a3f6f3b">The synchronous/asynchronous mode is defined within the scope of one Application Entity and not within the scope of the association between two Application Entities. The communication mode on the association may be bi-directional if agreed upon during association negotiation (i.e., both operation and notifications are simultaneously supported, etc.). Following is an example of synchronous mode, DICOM AE A may send an operation request to DICOM AE B and DICOM AE B may send a notification request to DICOM AE A before responding to the operation request from AE A. This is considered as synchronous mode because each AE has only one outstanding operation or notification.</para>
  </note>
  <para xml:id="para_e6f84eb2-7bb4-476e-b504-9e8bd8ee6b25">The mode selected (synchronous or asynchronous) is determined at Association establishment time. The synchronous mode serves as the default mode and shall be supported by all DICOM AEs. The asynchronous mode is optional and the maximum number of outstanding operations or notifications is negotiated during Association establishment. This negotiation is accomplished by the Asynchronous Operations Window sub-item structure as defined in <xref linkend="chapter_D" xrefstyle="template:Annex %n"/>.</para>
  </section>
<section label="A.5" status="2" xml:id="sect_A.5">
    <title>Association Release for DICOM AE</title>
  
  <para xml:id="para_91a4e5d8-6a9f-4bca-b4a9-7ce85ffcbaed">Only the DICOM AE Association-requestor may initiate an orderly release of the Association. This shall be accomplished by using the A-RELEASE service defined in <olink targetdoc="PS3.8" targetptr="PS3.8" xrefstyle="select: labelnumber"/>.</para>
  <para xml:id="para_44f5f234-ac38-43ac-8bee-59367aaba4fc">The DICOM AE Association-requestor shall not release the Association until all operations invoked have been confirmed.</para>
  </section>
<section label="A.6" status="2" xml:id="sect_A.6">
    <title>Association Abort for DICOM AE</title>
  
  <para xml:id="para_90e34f74-1b78-4cbd-80d2-f1fa7b8d716e">Either DICOM AE may initiate an abrupt termination of an Association. This shall be accomplished by using the A-ABORT service defined in <olink targetdoc="PS3.8" targetptr="PS3.8" xrefstyle="select: labelnumber"/>.</para>
  <para xml:id="para_eac788fb-74bf-48dc-9fd0-8395336cfd94">Upon receiving or issuing the A-ABORT service primitive, the DICOM AE Association-requestor and DICOM AE Association-acceptor shall fail any operation that is outstanding.</para>
  <note>
    <para xml:id="para_23d4e095-3059-41c5-96cc-57227dbf4dd8">The Association services and presentation services defined in the Upper Layer Service in <olink targetdoc="PS3.8" targetptr="PS3.8" xrefstyle="select: labelnumber"/> are a fully conformant subset of the services offered by the ACSE and the OSI Presentation Layer.</para>
  </note>
  
  </section>
</chapter>
<chapter label="B" status="1" xml:id="chapter_B">
    <title>Index to Application Context Name UIDs (Informative)</title>
  
  <para xml:id="para_d02606ed-1092-4e5c-b26a-26f172166eb9">Retired.</para>
  
  </chapter>
<chapter label="C" status="1" xml:id="chapter_C">
    <title>Status Type Encoding (Normative)</title>
  
  <para xml:id="para_be9eff79-eeca-42b0-bc00-5a7a46af4cd3">The following sections define the encoding for the Status Types supported by the DIMSE services. The applicability and semantics for each Status Type (i.e., Attribute List warning, etc.) are defined in the DIMSE Services. Each Status Type is categorized in a Status Class and represents certain Status Meaning within the Status Class.</para>
  <note>
    <para xml:id="para_59b902cd-eb56-4872-bf4a-f68b719a4d70">The Status (0000,0900) Command Element is required for all Status Types.</para>
  </note>
  <para xml:id="para_ee0ea824-ffe0-4116-86b1-e072ac9ac114">All Status Codes are assigned according to the following Status Class convention:</para>
  <informaltable frame="box" rules="all">
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_770c1afb-3721-46d3-88b1-21d302f06dc0">Success</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f114bb1e-0787-42b9-b48c-12e00ae1889c">0000</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_fec1cca0-1dcc-4393-aa1c-ccc7e5374094">Warning</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_46556559-c937-4060-9549-016a558825cc">0001 or Bxxx or 0107 or 0116</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c5a498a4-5090-40ae-8825-ea87dee951f2">Failure</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a09491cd-a584-4212-a160-fed36772dca4">Axxx or Cxxx or 01xx (except 0107 and 0116) or 02xx</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b63554c8-c6f6-43d9-8b96-bade1172c73f">Cancel</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8a752f53-516c-4070-ab95-f7b4bf2aa3d7">FE00</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_4782d556-3659-4bef-86e8-e43a96266ea9">Pending</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2ce4d202-210b-40ed-bc62-3a0c3a3474c6">FF00 and FF01</para>
      </td>
    </tr>
   </tbody>
  </informaltable>
  <para xml:id="para_6b754cb7-48ba-4d68-a37d-9d2634c5daa1">Status Codes with values 01xx and 02xx are reserved for assignment by DICOM Standard. These Status Codes have standard status meanings for DIMSE Services that shall not be modified by a Service Class definition or an implementation.</para>
  <para xml:id="para_2eaf3870-dde7-49c0-8024-d4b844206ed0">Status Codes with values Axxx, Bxxx, and Cxxx may be assigned by the DICOM Standard or by an implementation according to the definition of a Service Class in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>.</para>
  <para xml:id="para_55bf46ef-d5c4-49b3-adb1-5b5a4855c75d">Implementations shall not use Status Codes with values not listed in the table above.</para>
  <section label="C.1" status="2" xml:id="sect_C.1">
    <title>Success Status Class</title>
  
  <para xml:id="para_3817868d-fbc9-435d-9b29-b2158df95094">Statuses in this Status Class convey that the operation/notification completed successfully.</para>
  <section label="C.1.1" status="3" xml:id="sect_C.1.1">
    <title>Success</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_dd48f405-cdb8-4491-8931-91ad1a2f9482">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_1ce8681b-cf11-4eee-a63e-66542f5abba8">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_22de2f22-c09b-4745-822c-e0875c1bb734">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_447162e1-967d-4971-aae6-c9fe5c073f15">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_801d019d-9207-46cd-8186-4354ec7baf37">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a215f902-f00c-4bdc-ad20-619a3b894ee6">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7267a064-8010-4053-ab25-fb1f80f21757">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_96b56c1b-a874-4706-a51d-26f1fc26ce26">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b5b22578-4881-4c20-a728-5d7668b2765f">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a8d0e29e-063f-4ef7-bf87-8256dbdb5b79">Confirmation status of the operation. The value of this required field shall be set to 0000H.</para>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
</section>
<section label="C.2" status="2" xml:id="sect_C.2">
    <title>Pending Status Class</title>
  
  <para xml:id="para_790beff3-d7ca-4b52-a9e6-6996217c4264">Statuses in this Status Class convey that the operation/notification is continuing and additional Statuses are expected.</para>
  <section label="C.2.1" status="3" xml:id="sect_C.2.1">
    <title>Pending</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_678e7374-a2ed-42c0-aadc-f6dcdb362be7">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_7becb56d-adcc-436c-86ed-7774f2e40b80">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_8fc54274-5926-4711-8eb2-043f11165f0a">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_7077b71b-c759-4da9-afbf-bac15c325caa">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_05d998b6-97e6-477f-b272-96badb05c3d2">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_eae674dd-c713-40b6-b845-c270a4fd2ae0">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_32d91373-f113-46c5-b478-a031acb0d958">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_58194f34-07e7-4232-a571-a0181f96bea7">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4e1ff789-caf1-48c6-85ab-43bcacb5c7bb">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d5792d61-0a3a-45e9-af54-4391f5515703">Confirmation status of the operation. The value of this required field is Service Class specific and defined in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>.</para>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
</section>
<section label="C.3" status="2" xml:id="sect_C.3">
    <title>Cancel Status Class</title>
  
  <para xml:id="para_c41c5ebe-5ad3-4088-9a82-aa9b1b69fc80">Statuses in this Status Class convey that the operation/notification has been canceled.</para>
  <section label="C.3.1" status="3" xml:id="sect_C.3.1">
    <title>Cancel</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_f8ad3d09-f585-44d8-a147-d2a198ca2a26">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_8c1b4027-08eb-4f59-9209-17410b3d94f5">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_b6112612-93c3-4d99-b5b9-4f22c7a9d9ee">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_fee86bb0-1e3b-44d8-a522-107d7612545c">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_ab426a30-c062-4cd7-8169-f4a2a6d8e1b0">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c9ea30ec-6cdd-4cc5-9692-9b98ca584231">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_beb29ab7-2f93-4359-b7a0-d555affb0900">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a45e24f7-1a66-4e8a-938d-a7ec1d2949e9">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5668c86e-a32b-4419-b610-663893a2aaa0">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3c1ee081-3d6e-4a27-bab4-1887a301ed1a">Confirmation status of the operation. The value of this required field shall be set to FE00H.</para>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
</section>
<section label="C.4" status="2" xml:id="sect_C.4">
    <title>Warning Status Class</title>
    <para xml:id="para_6356ac33-b862-492c-b03e-373c7f18514a">Statuses in this Status Class convey that the operation/notification has completed, but a deviation was detected that is reported as a warning.
      The semantics and behavior of these Statuses are defined in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>.</para>
  <section label="C.4.1" status="3" xml:id="sect_C.4.1">
    <title>Warning</title>
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_b623e010-6d39-4e70-973e-5fa53e8597da">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_31f87312-3925-4ba1-a4cc-e9dde9a9b59f">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_6879076f-7d5b-4085-bbba-703424fc3ecd">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_b0a02651-20ff-46af-b882-4a9d25e628f7">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_f2155034-d9e8-4d37-b083-7fc93b6003e3">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_2f1d0247-3c43-4127-ba03-24b31b5e6ac1">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2a7cc868-841c-4384-a5e9-59c98a9e29c4">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_3323ef0a-9247-427c-bc6a-9cb6d24fb5ba">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7d8614e3-8ea0-41c2-991b-307a4a31bc5e">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f873084c-2497-412b-9958-26967b62c598">Confirmation status of the operation. The value of this required field is Service Class specific and defined in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1dd53563-684f-43d0-b99a-a70d31bfd6e3">Offending Element</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_83b60211-272f-439a-8adb-1980fd71198b">(0000,0901)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4494ad1e-9387-4958-95ef-388b5dc5b1cd">AT</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6c9dcfc9-ce7d-4d11-9116-6ac49a369d1c">1-n</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_2c728c6f-7138-406c-8f47-50d0c54b534a">This optional field contains a list of the elements in which the error was detected.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_fbd4670c-270d-4671-9232-805174533867">Error Comment</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_790f1a91-38fb-4d32-8ebe-be2eb7110e51">(0000,0902)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f7546e72-4c7b-481e-acb3-54736bd7c0d4">LO</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5fffd454-be8e-4888-8641-9c5593f74f09">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_7422e51d-1603-44a5-9b21-3286e9c0a9e3">This optional field contains an application-specific text description of the error detected.</para>
          <note>
              <para xml:id="para_f88ca781-273a-4732-a8e9-a53328d3b9c1">Only characters from the Default Character Repertoire may be used.</para>
          </note>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
<section label="C.4.2" status="3" xml:id="sect_C.4.2">
    <title>Attribute List warning</title>
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_d341dc93-10e0-4050-8931-b099373b55f0">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_f13e2669-c1f6-4f28-aa84-5f1a4987203c">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_df95808e-5998-4d97-abfe-ecb5d2116e75">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_e9ef74a3-b549-4258-9702-d738bf8ef24d">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_68c7dbd6-d8f3-4dfb-8230-843423a3a32d">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0f4642ea-ac26-4388-8183-ef61dd300e02">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_783e32f0-eb06-4d5f-b4cd-062946a91ac3">(0000,0002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_32f94326-b66c-4249-a8e4-8c8a2d1a5468">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4a77741a-c650-48b1-a4bf-7a73c061cbc2">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_65ac4f59-9672-4d20-bf50-4aae2cb3d74f">This optional field contains the SOP Class UID for which Attributes were not recognized.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_25481777-354f-4b7e-a947-683b70a56feb">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b3cf29b4-5d3b-4b46-884e-70eac0758c88">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8d8e8a90-903f-433a-85ce-9bda8623b856">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5a26d26e-268a-4341-a369-770fc6770ddb">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e8d127ff-3c36-4621-89a2-4f16679c028c">Confirmation status of the operation. The value of this required field shall be set to 0107H.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f2628416-484a-4924-81a0-a7c83338097d">Affected SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e98c1aa5-002a-4ef2-9cf2-b91d8e0f0185">(0000,1000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2a45d33b-c159-40f2-b79d-902d29f06837">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a4b8df3c-83d4-4aa1-8ba6-93778a62e5ed">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_83fd2a12-1ea0-461e-acb3-086fee9e8052">This optional field contains the UID of the SOP Instance for which Attributes were not recognized.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1080a59a-40ee-4104-98b6-9dd179d7a990">Attribute Identifier List</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_863cb1ef-aa7c-483b-84c4-1f00cbba69d8">(0000,1005)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0a2be9bb-fb91-4d8f-a3fc-b7510c89214f">AT</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5de4b07a-b890-4f17-94ad-449c49923f1e">1-n</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e2c64014-8316-4ef9-a46b-bb854f547b38">This optional field contains an Attribute Tag for each Attribute that was not recognized.</para>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
<section label="C.4.3" status="3" xml:id="sect_C.4.3">
    <title>Attribute Value out of range</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_fff719a6-8423-45d5-8318-5e02e26a17ea">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_e0742d9b-b76d-42da-802f-b36a9a96769e">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_d6849466-21cc-49c1-9051-c6db056322fa">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_adee251f-1bb6-4f56-a753-7e4c0aa21861">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_4c10ea24-d1e6-4aee-9048-1fb6bb3c8f9a">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_85bd0f68-118f-4643-95db-c1a7899ae011">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_09b30346-4663-4e47-a238-82a9a5a5cf4f">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e2582b68-4ce4-4043-84ef-8ab574bc45ae">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_cf200aec-cf8c-43a4-857d-c80339ffd713">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_2747f7b1-ca17-477e-9f34-d2a27eadea64">Confirmation status of the operation. The value of this required field shall be set to 0116H.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_64365d73-53aa-43e2-811c-744b3ce572e4">Modification List/Attribute List</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2773aa8d-7952-4a77-8adf-057a5681ac45">(no tag)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_024b22fe-0821-4856-842a-8fc73c8f243f">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_bf28c202-bfc7-447a-9708-62255da8b3ef">-</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_80886a1e-f186-4e4e-9af7-2e6cc0b79b4f">Optionally contains the application specific Data Set to only encode the invalid Attribute Values conveyed in the Modification List of the N-SET-RQ or the Attribute List of the N-CREATE-RQ.</para>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
</section>
<section label="C.5" status="2" xml:id="sect_C.5">
    <title>Failure Status Class</title>
  
  <para xml:id="para_7cd9660c-8a13-40f5-9d7a-4b91d7d972a1">Statuses in this Status Class convey that the operation/notification failed and was not performed.</para>
  <section label="C.5.1" status="3" xml:id="sect_C.5.1">
    <title>Error: Cannot understand</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_c4c5ce71-a77d-4c9f-b837-5e3bc3fcbfa2">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_948f1fa4-50e6-4896-834a-e8562ec3c609">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_d60dacec-f979-4607-a155-bb2661fd6493">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_446ae966-5138-46c8-a682-04b932217003">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_c41f45c0-03c4-48ec-b5a5-f60394818cab">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6560c1bc-5c04-4673-bce7-ff0969efaf2d">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_91792d9c-9d7a-49cc-b20c-f1b19cb3cb54">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5b4ddd21-fedb-48bf-9f36-a7c79b27600c">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_31020cd1-b847-47c9-a982-3fcc1a88b23b">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_ac511715-2850-47f7-9f65-9ca0d349eba4">Confirmation status of the operation. The value of this required field is Service Class specific and defined in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3efb4af9-3210-4f7a-a548-c657a9d50827">Offending Element</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_57bc16e6-65fa-4440-bf45-f97656e0da74">(0000,0901)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_92a7dd56-d411-4e2c-bd20-5be4d216d94a">AT</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_28d12758-b26a-433d-824d-4cec326d136a">1-n</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_43b996a5-803e-422a-acdb-6b76abfc57a3">This optional field contains a list of the elements in which the error was detected.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_57d5687f-c2f7-4688-8ffb-e1987f29702c">Error Comment</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_748bf8be-4d04-4ab6-bdc2-619ae5f55305">(0000,0902)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2519ba67-faed-4f06-a837-7d53a060ddc2">LO</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_cfe562aa-ee08-48e7-a206-a1ccba3d7ff0">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_fbef4775-c90d-47cd-b516-69b2846b4d7e">This optional field contains an application-specific text description of the error detected.</para>
          <note>
              <para xml:id="para_478ad0e5-351d-4c33-b796-eb8128ca76ca">Only characters from the Default Character Repertoire may be used.</para>
          </note>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
<section label="C.5.2" status="3" xml:id="sect_C.5.2">
    <title>Error: Data Set does not match SOP Class</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_81fa6cd3-0241-4eb8-84d4-cd7f568173c9">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_84657df7-e3a3-4ff1-a4b5-109762a94ff0">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_224a4a7e-878a-4b24-bb4a-02ec155c72f0">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_59c9190c-a0b0-4506-a4b7-a9813e7979d5">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_8053c7d1-e137-4a66-bf2d-e533709ef355">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a56d5dd4-156d-4002-8d5d-1121cab59aa2">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ff5933c9-eaef-4f19-861a-81e97b6b2ba9">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a396193a-0a21-4ebb-bd38-f4956559b2f9">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5c674c90-5091-4133-ab2a-290697edf4fb">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1e107f97-44ee-44f5-8230-605550a82932">Confirmation status of the operation. The value of this required field is Service Class specific and defined in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_aef87519-dd69-4730-8dde-77ac05127d6b">Offending Element</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8c70361a-59ba-41d8-aad5-c181a685aa98">(0000,0901)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1775672c-b646-4660-bd04-66c302a871b3">AT</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_08b17286-a752-4cfe-b9de-aafd40ab3c00">1-n</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_cd6fbe33-34fd-4048-86cd-329d6c9a3171">This optional field contains a list of the elements in which the error was detected.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a780951a-b171-4d9f-9d7b-40adc00077b7">Error Comment</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d9911cac-59f9-4c85-91d4-127947dde0e4">(0000,0902)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_678a12e1-fd37-49e6-b965-e347b69ac70a">LO</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_02266cfb-c352-4e50-933b-4d629de32951">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_7665822a-f455-4ec8-8320-54a11ce01f07">This optional field contains an application-specific text description of the error detected.</para>
          <note>
              <para xml:id="para_68e1a14d-33eb-434f-9218-cbcf2a5d966e">Only characters from the Default Character Repertoire may be used.</para>
          </note>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
<section label="C.5.3" status="3" xml:id="sect_C.5.3">
    <title>Failed</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_593cb410-d3e4-4dac-b21c-821b878692b4">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_13e483c5-4693-4a7b-918c-8ece296167c0">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_cfbf2353-b766-4eea-9ded-81d81c7e08ee">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_7edeaee0-cc1e-49de-b5c2-1f9b8e009c93">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_f307e8bc-bbb2-4037-8490-e76134f48496">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_021a9392-2ffa-43c0-b9fd-bb1746776325">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5c522abe-d7c6-4689-b64e-ca0d08fa6402">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e012c713-6171-42bf-b141-79914fd511ed">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e84425e1-1691-4736-8b7b-944ee082e33c">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c64a4d81-b5ea-4607-a75f-84b89b313279">Confirmation status of the operation. The value of this required field is Service Class specific and defined in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_abcaf499-da1f-4ab5-b5f7-17e605830c37">Offending Element</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8ba2541f-bf45-4e68-994d-eb3c97a495f2">(0000,0901)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0d32d16d-fdfc-465c-a60d-0c7c06bcd020">AT</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f723e93d-93fc-4e1e-84f8-09ec5005c343">1-n</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_db34902a-f793-431e-a7de-ce9bd08a1886">This optional field contains a list of the elements in which the error was detected.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0e86e200-a899-4529-86f4-fa79e9e55023">Error Comment</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d585f6ac-9f84-4731-abc3-5409ea29b2ee">(0000,0902)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5352b9b1-074f-402e-8807-0ee95abd6540">LO</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_94795f6e-0b26-4cd5-9e7c-aed305f34818">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_537d633e-0e53-48d6-b389-9a991ace83ba">This optional field contains an application-specific text description of the error detected.</para>
          <note>
              <para xml:id="para_614899f8-9374-4787-a45d-9e93f9c57fba">Only characters from the Default Character Repertoire may be used.</para>
          </note>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
<section label="C.5.4" status="3" xml:id="sect_C.5.4">
    <title>Refused: Move Destination unknown</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_3c6e35a3-9f0e-4ca2-9768-c19804e66275">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_1e8e4698-7513-44a7-9fed-3f465734b8a3">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_236cbae7-1203-4308-a0d4-6274963028b0">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_57fb5d79-b942-4a5b-910e-4ba873658bc6">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_7e4b80ab-2ffe-4253-82d7-fd6a9580961c">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3b380706-40aa-43ee-9cb4-d4eb328e9edb">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_227b215c-f730-4b84-adb9-bc8ab376fb4c">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_79401989-ad0c-412b-92bf-bbd1b1fbf6e2">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_aa0fbe4d-8be4-4a49-a358-d2ab9d8f1e9e">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c6f3f5bf-504d-4fa4-8350-980323d3a620">Confirmation status of the operation. The value of this required field is Service Class specific and defined in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_2580afff-5064-445a-b6ca-9015c71b814b">Error Comment</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d005b57c-ff8f-42e3-a934-076300cf302a">(0000,0902)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_25151299-ad3e-45bb-9ea1-3986db06d638">LO</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f4a1a7d7-671b-44a2-b9fc-5a59edefa558">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0f5e3abb-a664-41c1-8922-78a3878d43c5">This optional field contains an application-specific text description of the error detected.</para>
          <note>
              <para xml:id="para_6224e57e-e015-4fee-90fb-f7ac3e4cbf6d">Only characters from the Default Character Repertoire may be used.</para>
          </note>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
<section label="C.5.5" status="3" xml:id="sect_C.5.5">
    <title>Refused: Out of resources</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_4b009109-bdff-4d0f-b61a-cd3e3322c525">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_4db9b7ac-5138-41eb-b6a0-22b3b084648f">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_fe1e42af-c21a-4b35-aacc-dea9ae71cdd8">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_9aca9297-5481-4a3f-beb6-979edec0a244">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_1d29e651-b4fc-4645-9bf1-36fad7b9a1ed">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_81d4fbbe-87cc-4ce0-b416-ac00c75e6f8f">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_dc3640b3-c043-421e-abe0-1aedc0828acf">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_3bf4ef3f-0455-4de3-a495-0f5a25f5ab8e">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_eee03828-6a3b-4466-b2e7-b49f6205bdb4">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_04b7fec4-7cbb-40b4-ba66-3d6409b7e049">Confirmation status of the operation. The value of this required field is Service Class specific and defined in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c1c85b85-2221-4961-ba36-eb1a9defe537">Error Comment</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0e2f29d5-8168-4ce4-8bc6-81369c9ac19e">(0000,0902)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6af97d05-0a0a-4dfa-b2f3-34d60bbcc27e">LO</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0c678bc2-abdd-42a6-9d97-5aab1234ed94">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f3816abd-0f8d-449b-b3fa-ea7ded789d2b">This optional field contains an application-specific text description of the error detected.</para>
          <note>
              <para xml:id="para_3e988353-cdc1-477c-81c3-42104cd9dd85">Only characters from the Default Character Repertoire may be used.</para>
          </note>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
<section label="C.5.6" status="3" xml:id="sect_C.5.6">
    <title>Refused: SOP Class not supported</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_279820ba-07a5-4c43-87ad-e878e88e99eb">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_1c283258-45ba-4035-9a4b-4b6e574121ec">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_8051e2fb-bef9-4f2a-879a-d7c17a98f3b9">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_daa518cc-4ea4-42d2-82f3-f4c5451c8d45">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_cacc8505-0d9b-4f79-8e79-48f42e35f179">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_7cdc0eff-a5d4-4fd9-b4ff-4ea3aa53b9f6">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2a263261-5102-42a5-b257-60bd0550a2a1">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_612d3e0e-2f0f-4b64-b931-310fcc1d00a7">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_3218c84f-02ba-467e-8581-bf517b2e863b">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6bac15d8-cda3-4b43-a0f5-030a9a607a5e">Confirmation status of the operation. The value of this required field shall be set to 0122H.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_4517ce72-e305-4cbb-a558-b601e7552fc8">Error Comment</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6d5b0449-b62e-4067-bf59-24c177fd454d">(0000,0902)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e2aa6c41-cc15-450b-b007-837d23b1c647">LO</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_60ba93e8-6d94-404e-8cb5-e8abf61e9638">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_744f2e51-5cb1-49d7-868e-a9d72099fa1b">This optional field contains an application-specific text description of the error detected.</para>
          <note>
              <para xml:id="para_3e524dd5-a6d3-4783-b8e8-b7714988f31b">Only characters from the Default Character Repertoire may be used.</para>
          </note>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
<section label="C.5.7" status="3" xml:id="sect_C.5.7">
    <title>Class-Instance conflict</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_02ff8677-5e3e-4f78-9cfd-d33c4fb6671c">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_06c08ce7-8c20-492b-b433-8a9ffe1e8eeb">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_a212018f-eedd-43a0-bdde-2e43fe7c3084">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_9cb465f4-6cea-4c71-8b3c-e0ec163dc016">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_5d3162f2-4b53-4d57-bafc-cdef3bfe73f5">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_8d537a32-224d-41fa-9ab6-47fa806669c3">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_865ab170-85eb-4097-a887-cc6b4e7aa78b">(0000,0002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b198a6e4-bee9-4495-9e7a-3886888ad716">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_027e6826-b971-4c10-af86-2daa32a51465">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9914f4d2-7742-4787-bf84-9af737481b74">This optional field contains the SOP Class UID for which the SOP Instance was not a member.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_724ef585-9d30-4a6c-a193-a3f9320e122f">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_56ed36a8-dc42-49fe-b844-6e414bbc8684">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9b6eff8e-cdd8-4648-bed4-07274af8f500">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_3976566d-6677-4db6-999a-5e258e688208">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_72f8a154-708b-43ae-9794-c4379abc1b22">Confirmation status of the operation. The value of this required field shall be set to 0119H.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5e320196-e84d-4df3-924a-70e0dac91079">Affected SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4db2ea81-d604-4486-a4ce-88bae4829ee4">(0000,1000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f0c7dc7d-984f-4c7d-8598-bc1793b96c9e">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_62c6bbe8-1385-4e82-8e78-8063c71c58b5">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_cbbfaeaa-cfc9-4de3-970c-a7cff017f8e9">This optional field contains the SOP Instance that was not a member of the specified SOP Class.</para>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
<section label="C.5.8" status="3" xml:id="sect_C.5.8">
    <title>Duplicate SOP Instance</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_b32759b5-7c65-4bd6-8dae-9d3e1b64fbdb">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_e044794e-fd4f-45ac-ab4a-ee1068bbf9b7">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_524caabb-5fd1-4a26-aa35-fb040d5e5d72">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_41735f8a-953c-4b6d-b032-466b2448be14">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_ec3cdf2b-d9b2-4060-8d29-cf157232ee40">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e71d68f7-1518-432d-a331-2aee8d755945">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_84d273aa-c815-4606-9ec6-592ff24fb0b4">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a6bbeccc-a464-4ecd-83b8-2f6edf67b5d1">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_068a3971-3cd6-4995-b47e-39b62e5ddde5">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_ccac300f-22cd-4410-a1f2-fd65260b4346">Confirmation status of the operation. The value of this required field shall be set to 0111H.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_656ce91c-81cf-4807-842f-a383cab9e57d">Affected SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4f395c78-d90b-4152-bf92-8bcafaf4e1e0">(0000,1000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8ce9798b-3871-4f94-8c6a-759212d71c0d">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_46d84843-85d0-47d3-a30b-2a52456faa60">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_fea151b8-1102-4f7d-93b7-6c3c07130920">This optional field contains the SOP Instance UID that was already allocated to another SOP Instance.</para>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
<section label="C.5.9" status="3" xml:id="sect_C.5.9">
    <title>Duplicate invocation</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_9bd8f771-57d1-475a-9253-850b42d575f9">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_78fde120-e674-4910-a91d-bb1376982bbd">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_b1887aab-5181-48b9-8f47-48bc5f440f07">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_9dd1ed79-5ab8-4a72-a48c-5de7d912a376">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_7da44b02-1b9d-47d8-8acf-16da94bd1c2d">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_8f0ba854-31cd-4803-8807-854544b20db9">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_195a2876-c55f-4c65-9f2f-fa4551bb626c">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_40345201-b883-4e6d-be8c-ecbe5e01dfc8">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_97906316-b262-41bb-951d-502544c293de">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5e0b7d76-f8e7-4d10-bf4c-68344aa62f9a">Confirmation status of the operation. The value of this required field shall be set to 0210H.</para>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
<section label="C.5.10" status="3" xml:id="sect_C.5.10">
    <title>Invalid argument value</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_9a66a837-c30d-40b6-ac68-585827a3f3bf">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_2cebe675-c084-4da2-952e-6a8814238cc4">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_d6332847-be35-4f2b-8786-8dce8da929b8">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_839cd713-8e67-43b4-b1fd-f0c0c5358b21">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_81ec5275-cfce-4b3d-9530-e593a081b942">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_8f6fab46-3365-4d8e-8a1f-61e9240ba52f">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c3f05c28-1b86-40bc-9b75-e9d2e2dea745">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_fa117535-d85a-4ab0-9918-f4300b10b57e">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9ed937cf-074f-456c-8213-a4489fe910e4">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_344fbcb7-ee40-468f-a276-8d95b63cd0b7">Confirmation status of the operation. The value of this required field shall be set to 0115H.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_4461ff3c-6a32-475d-adb3-f82b907d6a9a">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_44ceac5c-c75b-4078-b6d5-e9c4687352a8">(0000,0002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_590685f8-7990-4e3a-816a-6f118f0892f0">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c2625bf4-5846-4a2d-8018-89954ad36145">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1f1926ac-882b-4ebe-98c7-ab288177566a">This optional field contains the SOP Class UID for which an argument value was in error.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_2cca4365-44af-48f5-be65-29949fa68a96">Affected SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_733c4a17-8250-47ec-80ac-591688a13cac">(0000,1000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7e8af4db-8fe0-4969-ba3e-5d9461f6817e">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4848cadf-c443-48bb-9940-c643ef6a7550">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a59c4045-2207-4b96-9dba-26368fec892a">This optional field contains the ID of the SOP Instance for which an argument value was in error.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_4420d9e5-27f7-4feb-9442-a42b08d6ff79">Event Type ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6a8b07c4-57f1-4021-9aaf-061c32e22f1a">(0000,1002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d61174f5-295c-493c-a372-ce3871bf1dc6">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_03619ed5-5a64-4b93-9009-7848be2cff2f">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f83df52d-6501-4818-a3cf-436c2b6dfc1f">This optional field contains the UID of the Event Type that was not recognized. Permitted only in the N-EVENT-RSP.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_7e8e422e-120b-4b8b-a442-34fa8472c32e">Event Information</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_72480e26-1952-4f83-b0a9-686c0df13bbb">(no tag)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_060d2f0a-e637-448e-92c2-b02031d54f27">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2190d68b-dfe0-4ff7-ac22-6a9394830684">-</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_20eace81-c163-488a-af48-9dbd2eabe58a">Optionally contains the application specific Data Set to only encode the invalid argument values conveyed in the Event Information of the request. Permitted only in the N-EVENT-REPORT-RSP.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_95ed15cc-21fc-44a3-adf8-c540997ba71a">Action Type ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1c762442-7986-4072-bf09-2a9f639ae18b">(0000,1008)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_cf220266-ef1b-49ef-a667-f211d5ee57b8">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_af546bfd-9c58-49c2-a736-77bc570cd4a4">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_7e8179ef-63a6-49ff-b329-7eeb817a759b">This optional field contains the ID of the Action Type that was not recognized. Permitted only in the N-ACTION-RSP.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_ea8658b8-14df-4c38-91ce-5c1c8d6aca27">Action Information</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d683bac5-e993-4bad-9432-7d1c4b7763e3">(no tag)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9b890d0b-e0b4-4f96-9029-07408f29b886">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2738c9a5-037d-451c-b25d-ad22fdeb343c">-</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d9cad485-12f1-4ae3-8ab5-29b43c65acf4">Optionally contains the application specific Data Set to only encode the invalid argument values conveyed in the N-ACTION-RQ. Permitted only in the N-ACTION-RSP.</para>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
<section label="C.5.11" status="3" xml:id="sect_C.5.11">
    <title>Invalid Attribute Value</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_4190b84a-bc89-4932-9ae0-a9785aaf5ac1">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_90d883f6-64eb-4cee-814f-7f9d615b655f">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_87a0d257-f795-430f-b7c5-65c72f0c010b">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_c379f42b-e83e-4fcb-8734-10853aef4b98">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_cac7f44a-f2e0-42d0-b31d-f62b8a1a1e03">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_7e6a65bc-ff6c-4c1a-b18a-dfcbeda3d593">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_24de4e2f-6906-4d5d-b4ee-f551a45c55ff">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_796b1ac0-abd1-4bc1-8275-98afd286a8ff">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a0a7d262-506a-4a47-85ec-990ecb267ce0">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_40158044-f068-4a81-af3d-720d469624ae">Confirmation status of the operation. The value of this required field shall be set to 0106H.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_eaf52c60-d09c-476f-816a-9ea0a151df5c">Modification List/Attribute List</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_763f378c-f4db-4a6b-bef6-f499cb19ed82">(no tag)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a22be5e0-dafb-40f9-aa9e-478c70e801c0">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_aa1029f8-3bdd-4a59-8dad-04dd83f4a944">-</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_bac82d15-434c-49c6-adfa-63396a25ed3a">Optionally contains the application specific Data Set to only encode the invalid Attribute Values conveyed in the Modification List of the N-SET -RQ or the Attribute List of the N-CREATE-RQ.</para>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
<section label="C.5.12" status="3" xml:id="sect_C.5.12">
    <title>Invalid SOP Instance</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_81187296-a0ac-4616-bc75-61f012264476">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_7693a3d4-d40c-41cc-8f53-40c3688fc753">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_a5f80cfb-d70e-44d3-a24c-33a9c5c23b8c">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_e219bbca-28ef-4a25-9134-1e95a4646b1e">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_93d61aa1-0cff-498e-bea3-f10f97397e29">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6932d101-f318-4f39-8429-fe61532ed7e3">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_df3c36fd-16d5-4be0-a969-94f11f6cce5f">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_af23835e-0d08-4df2-90ce-b4b2ab572f1a">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e07676ab-9aef-4679-b3d5-6c7cff2006ec">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b422e9e7-0afb-418f-82ac-fc390cb1697d">Confirmation status of the operation. The value of this required field shall be set to 0117H.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f041f747-5236-40f1-89eb-9d83df732c07">Affected SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_133502cf-568c-4e34-8526-35d87858309e">(0000,1000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_16a04b91-782d-4613-a9c1-738486b92653">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f60a01d8-1e6b-43f2-8e54-ea0a07d252ef">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a4f7c8a9-cbe0-4119-9251-92de4ab3bb92">This optional field contains the SOP Instance UID that violated the UID construction rules.</para>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
<section label="C.5.13" status="3" xml:id="sect_C.5.13">
    <title>Missing Attribute</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_6ba026fe-3cb7-400a-8f41-a7d1156fb9c6">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_8aedb07c-0ea4-4cf1-8559-573ee932ed73">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_7211d9de-6cc7-45d3-8f22-c391bb1d96e0">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_8afa3981-57af-4f03-95e3-9752c5895b9c">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_691b3588-bee9-41c6-8da8-622f27d7754a">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_53b2a3cf-cbc4-4875-9906-e0f6c9f5723a">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_453a31ac-3362-48e0-ac57-6e21a7bb3654">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6d05c8bc-0d33-45a7-a3c1-6b9fd7c33ab5">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f5922671-e7ee-4b6c-a70b-6adc9ab62219">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b61c6f94-2a00-4e4d-8040-03692ca60140">Confirmation status of the operation. The value of this required field shall be set to 0120H.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f23b5d24-dfb6-4823-b300-90856e8ca657">Attribute Identifier List</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9bd2ff69-ff89-421e-bbdd-a3aa509de6be">(0000,1005)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7a45fa34-70b9-43c0-873c-22cf467fc81f">AT</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b506eaa3-bd32-4a8d-af26-13372fe8452d">1-n</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d9c33064-7881-4efb-bdf8-2194cabadd53">This optional field contains an Attribute Tag for each Attribute that was not recognized.</para>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
<section label="C.5.14" status="3" xml:id="sect_C.5.14">
    <title>Missing Attribute Value</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_ebbdb637-bd84-49c7-bb98-cd96a481f02c">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_693cb62e-4063-46ce-9de6-7b18737f5621">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_6f4c4d94-1fba-4da6-a2a5-3fffaefee687">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_4f5fc035-c530-4eaf-bee5-a47f609dd6d3">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_82620779-ff42-42e8-b0d7-0cbbe00c65e2">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c1cc2328-8959-42d4-8557-4d223cdd47fd">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6e8c9141-4e2f-4cca-93e0-1b5308884d9c">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6c975902-2a2f-477a-ba7c-5cd63eba0eeb">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7eda7ea3-54c1-4ce0-b127-f8847611fcf3">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_4bf998c7-63e5-4192-a41b-5d16e6299691">Confirmation status of the operation. The value of this required field shall be set to 0121H.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_bdeaf392-3772-4423-a863-2ba7c61dd00c">Modification List/Attribute List</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e89ce29b-b3b0-4a5f-9fab-dbbb70c17ce0">(no tag)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9cdb6319-34cb-4422-b239-bccd9ed8a092">-</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d0c98aeb-8b33-4bff-a74e-8efc7cbec0bd">-</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a7a2be4a-a553-4fb8-8f36-68018f3339d9">Optionally contains the application specific Data Set to only encode missing Attribute Values conveyed Modification List of the N-SET -RQ or the Attribute List of the N-CREATE-RQ..</para>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
<section label="C.5.15" status="3" xml:id="sect_C.5.15">
    <title>Mistyped argument</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_b7242c67-5799-4c65-baac-3fff5d51060e">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_20cfc71a-98d6-48e0-9564-f06d446132e7">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_e7b13add-29e1-4120-a7f2-670e8f08c1b9">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_8ca1f5a9-d286-4d63-aa48-b7e0f1781e79">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_10786341-6854-4f67-aa3f-85b09df49d67">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_8ef37154-d4b2-4221-8bd6-8ef9fe3c3882">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_863f3393-8ec3-4dab-b5e1-b26354facc84">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4cd882e1-d9df-4858-b56b-f8979c3b03c6">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5c741c34-e299-4e91-8aa2-4707ad02185a">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1159812c-faca-478f-abc6-df030e11a34f">Confirmation status of the operation. The value of this required field shall be set to 0212H.</para>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
<section label="C.5.16" status="3" xml:id="sect_C.5.16">
    <title>No such argument</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_a44b3461-a1f3-4e2a-863d-6d234c23d919">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_bd086421-ae6e-4299-ad35-1b56085bc06a">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_a5d9d822-a4ec-47c1-a3f6-da59b5ebce72">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_17d28939-f06a-41e3-afd2-a3ed4cedf108">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_33621bcb-11fb-49f7-acb2-1bee25352712">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_bacca813-0128-489f-bd23-5bc8033c5e72">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_df58e9d9-72c0-48ff-b254-a2c90b023b30">(0000,0002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9498ad00-f205-4add-8002-e623d59a3f6a">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_39fbab2e-72e2-4d26-a68d-408948fa01c1">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_16b2906e-ce96-4a9d-a84c-ae4100382dd6">This optional field shall optionally contain the SOP Class UID for which the argument does not exist.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a601582f-c104-44e7-9263-2b9d6b2fe637">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8a0a2f50-f6c6-4b78-b8d3-4c82843465af">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8d5064ce-6dd3-485e-a54b-8fb496ded858">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_029f5513-a3ff-4e4e-a3ed-51f489677dc2">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9918996d-3a1b-462d-9e74-fa3e3cff482e">Confirmation status of the operation. The value of this required field shall be set to 0114H.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6dacf487-1385-4033-bf8d-d811ce23f272">Event Type ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_3f1c3158-39ee-463e-8612-2d5d6c60e3bd">(0000,1002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b9330eb7-eaef-4a69-8fc5-8218db1bd78b">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a1046aba-6ec5-4357-83cf-4ab10e2ef1c7">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_61278477-bbb4-4266-bf61-5000775bc9a1">This optional field contains the ID of the Event Type for which the argument does not exist. Permitted only in the N-EVENT-REPORT-RSP.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0f079465-ddf8-4484-a8a6-9ffb2936b407">Action Type ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ff357e2b-e52a-4c02-b386-c4a9721a96ee">(0000,1008)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_3c172bb7-7f93-44dc-8321-e8ea6cc80dff">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d05fb2a4-08f3-4995-b40d-381120600427">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_4ace67e7-4b35-4a6d-bc01-362e490004aa">This optional field contains the ID of the Action Type for which the argument does not exist. Permitted only in the N-ACTION-RSP.</para>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
<section label="C.5.17" status="3" xml:id="sect_C.5.17">
    <title>No such Attribute</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_05d55bae-271b-4b49-b395-11d162cba0c3">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_f5cf8c73-9d24-40f6-82d0-e9f5f1a2394c">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_aa26c958-158f-4393-80b3-41d62dae6913">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_e3d4f892-06ea-41c3-9591-c729c4678074">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_c0a688c7-0b34-46f8-85ab-bb2b93fed315">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d126e569-5038-4bc6-9112-2fee6be0c992">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8b0e777a-4193-4ea1-8e61-e24cf851153f">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_43372803-5ebf-4154-8894-f7c5dbac5da0">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f55b957b-57f6-419c-b7ee-f3b3e9080875">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c931afcf-16f6-4939-bb02-6e13be725c42">Confirmation status of the operation. The value of this required field shall be set to 0105H.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f824e09c-5558-4ba3-86a3-57c911a285c2">Attribute Identifier List</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ca143934-3646-4fa5-a677-6d1b67883b28">(0000,1005)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ecee021e-14a3-4190-98b0-4e0339799984">AT</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c4918b4c-e959-4633-a700-c85797a235bc">1-n</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_be057620-daaf-42b4-b905-d70dad9bb4f1">This optional field contains an Attribute Tag for each Attribute that was not recognized.</para>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
<section label="C.5.18" status="3" xml:id="sect_C.5.18">
    <title>No such Event Type</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_94d71a64-6836-4d61-aad6-2a00f1f4dec9">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_d2dc10dc-2612-4fee-bc75-6b720dc84b1a">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_4fd80dff-714e-4d12-9fcd-4ef669ba0ffe">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_f8f79069-ea67-4c5d-94cb-e72940ea6f54">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_8fa25637-3b3e-44a3-a0b5-d917b62f0241">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e9a3c4ca-29e3-4512-a526-27065a2cd638">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e34eab52-fb6d-4d02-acf5-5ad5bc8f4de3">(0000,0002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d664a3b8-f871-4deb-943b-a43ddf7afdbd">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_3ddc7e73-f9e9-465a-87c4-f1735c251a2a">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_348f0d4a-c175-4e01-916f-dc5b53187b62">This optional field contains the SOP Class UID for which the Event Type does not exist.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_ec9a7971-3f4a-4d21-97e7-5dcd60ad4c22">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_90265bf6-2f4b-4559-869b-ae31bed7b4b4">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0e348c6c-3e24-4e3b-91e2-e35c21ba30dc">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4c017daf-87b3-4c76-9df2-d2f3636b2a98">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d69355d1-e106-4b7e-a4a3-cdd6af95c4f1">Confirmation status of the operation. The value of this required field shall be set to 0113H.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5d191485-8ffe-4459-ae81-dfb8f748eb6b">Event Type ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a1726d86-7989-4b04-9382-2748f105ed2c">(0000,1002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_3140312e-7d2d-4a63-9a72-9dbd6d064e26">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0a8a300b-f332-4fb8-9e68-77c3de66598b">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_69186a45-3a8e-46a9-a00d-254812c5b301">This optional field contains the ID of the Event Type that does not exist.</para>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
<section label="C.5.19" status="3" xml:id="sect_C.5.19">
    <title>No such SOP Instance</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_031cd963-09b7-439c-95dc-2a388828b73f">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_2104b313-6cb3-42f1-bc4b-8a71531d5cbd">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_ce65ad82-79af-4d0e-863b-c0da466d6d07">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_0f01fdfa-d3da-4237-8433-bb2db3152995">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_054d1ca7-7bfc-4930-b45d-41a035bb0fff">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_516d99f1-1d78-4658-b4a3-1ec513189d25">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f9c952f7-fba2-4fae-b8f0-b7c4b1964aa2">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5980d1ed-830f-4ba8-84b7-718d24668f5a">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_909b24b6-c858-4d6c-adb6-44c5753415d6">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6d47fef5-b8b6-4ba4-b2a3-7883236b066e">Confirmation status of the operation. The value of this required field shall be set to 0112H.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_50dbcdce-5a32-4f41-8e7e-0550ed6a8ba6">Affected SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_aea36610-119b-4e3f-a796-c2b831b34ead">(0000,1000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_99739d65-fab1-4288-ac61-67e97cf98d90">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_fbdcaba3-3cb7-46b8-848e-0f4f39856f6f">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_296fb8b8-29b7-47bb-aef8-f9472494d15d">This optional field contains the SOP Instance UID that did not exist.</para>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
<section label="C.5.20" status="3" xml:id="sect_C.5.20">
    <title>No such SOP Class</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_f7d3434e-0836-48d5-98fc-8843c97a4303">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_b599c3d5-e452-4d85-90f6-c5b211d50672">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_2d27881b-bb69-44e2-94c9-6a66fa9c47d2">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_16e1ad8a-7c95-4e50-bcd9-59a948709b17">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_e9e1b8aa-52f0-4dda-99cf-29febc63f7eb">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_4e34626c-2e57-4859-97d4-8a57b1c9b555">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_40dc0225-7ba4-43ce-bd64-8091904fe281">(0000,0002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_19d8e045-e052-442d-89fc-4803ef9c451b">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_39800c6b-45d6-4eff-8de7-e17565311c1d">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9876af7b-68a5-47a1-8940-e42339b98fa5">This optional field contains the SOP Class UID that does not exist.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_4d84b7de-7e1d-43b9-b62d-34a983a2d3f1">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6d1acea6-8411-48ff-a517-6d63c8e4d7eb">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_876c15a5-e952-4ffe-b4db-cf9018dfeae9">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_74b4b9ba-1912-40d3-8464-e54c27510cf0">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_104fe34c-7f0a-4978-92bb-d73739551e88">Confirmation status of the operation. The value of this required field shall be set to 0118H.</para>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
<section label="C.5.21" status="3" xml:id="sect_C.5.21">
    <title>Processing Failure</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_78c0baca-f8d9-455d-bfad-d131c0817a13">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_3e4ff106-d56d-4f87-b510-6455eb1881a4">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_6ac75e0a-8199-4bc4-a8f0-f63e5d2fe483">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_75449e1e-7003-46e0-9811-fb352f74e054">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_8cbfe5ca-7309-45f6-b650-e5520a36519d">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_aece6773-baa4-43ee-bcea-1f4ddb86d0d2">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b709575a-36b4-439c-a0fe-3c35c865780a">(0000,0002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_90519d0e-461a-45d0-83e7-ca60cf7bad1d">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7e091cb7-3ccf-471b-94ea-72763dfad781">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3afc9dd5-017d-461c-8d1f-61800169de13">This optional field contains the SOP Class UID on which the processing failure occurred.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a26119fe-17f6-4c38-b267-5c9538f60620">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_cbbf731a-f1a6-4ed7-8ef9-b30012baa371">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7857ee12-e898-4480-961f-9f0d9c5eed46">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2304959e-d5a1-4cbc-9073-089ecdd629ed">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c96e3efc-a06f-4ab5-8a9c-e872293f069e">Confirmation status of the operation. The value of this required field shall be set to 0110H.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_ac59b52c-80b8-4d4d-9aad-e5b73b259dd1">Error Comment</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8505706f-ea2d-4710-b7c9-e152565ba985">(0000,0902)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_32736299-9d3a-410b-a7f4-646bd733db0e">LO</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a31bcfcc-da30-429b-8834-501d33c36e0d">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e179ea8d-4dc0-495e-b32b-45e748abd9fc">This optional field contains an application-specific text description of the error detected.</para>
          <note>
              <para xml:id="para_9aa9169d-2ed8-41b7-bf53-49ae428c5838">Only characters from the Default Character Repertoire may be used.</para>
          </note>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0cabd499-d1fe-4dc7-bd04-9c57ee93b4e8">Error ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0880d308-d571-4a01-aa41-df52ce2a0b84">(0000,0903)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_848ec87b-07dd-4601-b9de-71a547d8bca3">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f0b7282d-291b-4adf-8cc1-15ed8bbf44d8">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_363a8669-b158-4a3d-b612-893e4bf01de8">This optional field contains an application-specific error code.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_fae725c9-6466-404d-9245-fbf2ec367c1d">Affected SOP Instance UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_79c05c53-c564-4938-9063-597d0ec440d2">(0000,1000)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2b00698b-bdd2-4652-8aa4-378696206800">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_dced4d59-b4e0-46cd-bed3-a39d2b0e128a">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_69b2da0f-0977-4a55-99b2-45823c7d88c2">This optional field shall optionally contain the UID of the SOP Instance on which the processing failure occurred.</para>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
<section label="C.5.22" status="3" xml:id="sect_C.5.22">
    <title>Resource limitation</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_1452d899-0643-433d-bfb9-e8c6cd532820">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_a231070d-14d5-4bc0-87f9-371664fec5e6">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_b3ffc6ff-a688-4dfe-a1b1-11b0a0e97aee">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_12fced92-c5df-49c3-9801-050681b48f96">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_27f72689-96d1-4b8c-921c-86f84313509d">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b482e68f-6a8e-4857-afb8-2f34db9a66e1">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5e1bc8e4-b3e9-43c0-bfee-2ca5de6fd2dd">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_43a2bd26-90a5-4e91-b1f9-ada311b50e0e">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ade353bd-3455-4d78-9eed-ca44d73724ee">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_2a5dfcfc-8c24-4e63-b76c-a0d540420286">Confirmation status of the operation. The value of this required field shall be set to 0213H.</para>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
<section label="C.5.23" status="3" xml:id="sect_C.5.23">
    <title>Unrecognized operation</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_4c7180b2-68b8-40bc-af4b-1c85c0db72b7">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_26bc2495-fa03-4211-bff3-9490de0806a5">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_3616302d-ef55-4b58-b61e-b77a7294b6cc">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_a12ef988-12d1-480c-bf3b-a33276b93bd4">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_7dc7399f-7877-499b-a991-61289e58eefc">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f6ca840f-5b6d-42b7-a7f7-e429f5a9a70f">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a2c9d5fa-4279-4b1c-8c19-d50d875c9ddc">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_3d1af98e-180f-4839-b888-a49975fc7434">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ffa8b18a-8f92-47ab-aba7-f6396ccfbdd7">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9305e8da-75b6-4b74-b496-70bc7f8bb0fa">Confirmation status of the operation. The value of this required field shall be set to 0211H.</para>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
<section label="C.5.24" status="3" xml:id="sect_C.5.24">
    <title>No such Action Type</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_d3ee97d3-d532-4c6f-9c8b-40e55915567b">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_5c5f7c1e-10f6-4a28-993b-d42caa014e8e">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_5e898819-71a8-40c5-a0c2-224bfebda2a2">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_5543cb3e-e950-4053-a28f-e6171c351433">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_d4f4daa4-e00e-4b7e-88c6-593ff284737e">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_10785bbd-294c-475f-b180-53ef3b3b6e2d">Affected SOP Class UID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_66139288-f22d-44de-9ad6-51e76ed06423">(0000,0002)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_21bbe672-2894-49c8-b3dd-09b6bb166145">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4fe8214f-a488-4726-83ca-7eec4f175a8d">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a99d5159-f5ce-4ab5-a785-1523435ef903">This optional field contains the SOP Class UID for which the Action Type does not exist.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3bdd14e3-5fab-4ca4-8ba1-26b4d0e0bb12">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_dcfa20b8-5706-417b-bb78-65d03d396181">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_bea0ff2a-f0b4-4195-81b7-f3d9ebe3b1e2">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d36f0b37-3342-4881-89b7-54985c77d518">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5a8feff4-7b2e-42ee-aef8-4bed0be0bb2e">Confirmation status of the operation. The value of this required field shall be set to 0123H.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_ad6715f0-5d03-429b-869e-ab58f90a974a">Action Type ID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a4acee5d-bde5-43b4-ae82-22cfb78c0c93">(0000,1008)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_10dfd9fd-5f96-4246-b605-d4f370c189e5">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1b53571b-39b7-4803-adb9-bf0aed20e6d1">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_186b0658-ec0a-4be8-8fb1-40344d072537">This optional field contains the ID of the Action Type that does not exist.</para>
      </td>
    </tr>
   </tbody>
  </informaltable>


  </section>
<section label="C.5.25" status="3" xml:id="sect_C.5.25">
    <title>Refused: Not authorized</title>
  
  <informaltable frame="box" rules="all">
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_54e59dbe-33fd-4e43-80a9-1655fec1688b">
          <emphasis role="bold">Status Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_59d8a8aa-8a38-48be-91b3-3a6688063cb8">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_67cefed2-4a28-437f-8c42-e7bac329275e">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_ac89d7ed-6f8f-4441-90e7-20b272219e2f">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_c0d11303-7e3f-4857-af59-d3922f38487a">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_11eee1cf-a3da-4060-869e-72799e0e0be0">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b22851c1-b910-4714-a04d-d8c0cb97f31f">(0000,0900)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_3a2c6402-0725-4d9d-8105-d479a42185fa">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6359975c-db19-4b6b-ac8c-4d5f99beb120">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_bed991ea-c003-401f-aa17-fde6feb0178e">Confirmation status of the operation. The value of this required field shall be set to 0124H.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_4874ae66-7c4c-4222-941c-c2dad65bc8ee">Error Comment</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ea9ea97d-5a28-45e7-b157-b10c921ef08a">(0000,0902)</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e1035f36-5f63-4b65-910a-e3098c8ac49e">LO</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ccfeef0a-bb38-4910-9373-eeec323c68ba">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_342ee7f1-0f82-4500-b0f4-f2f8c5f821df">This optional field contains an application-specific text description of the error detected.</para>
          <note>
              <para xml:id="para_ea43a0b8-9a1f-4109-8b6c-eef35130e0f6">Only characters from the Default Character Repertoire may be used.</para>
          </note>
      </td>
    </tr>
   </tbody>
  </informaltable>


  
  </section>
</section>
</chapter>
<chapter label="D" status="1" xml:id="chapter_D">
    <title>Association Negotiation (Normative)</title>
  
  <para xml:id="para_ba715653-caf0-43fc-b9d4-c6dd7a341903">Association establishment is the first phase of any instance of communication between peer DICOM AEs. The AEs use the Association establishment to negotiate how data will be encoded and the type of data to be exchanged. This Annex provides an overview of the negotiation mechanisms plus a discussion of each concept, its objectives, relationships, usage principles and specifications.</para>
  <section label="D.1" status="2" xml:id="sect_D.1">
    <title>Abstract Syntax</title>
  
  <para xml:id="para_314f206f-f939-4947-9437-9586a3963bcf">Abstract Syntaxes specify the Application Layer Data Elements and Application Layer protocol control information (with associated semantics) that are independent of the encoding technique used to represent them.</para>
  <para xml:id="para_a62e83fa-d730-4112-8ff3-ddcf2c83bdac">Each Abstract Syntax shall be identified by an Abstract Syntax Name in the form of a UID. DICOM AEs use the Abstract Syntax Name to identify and negotiate which SOP Classes and related options are supported on a specific Association. Abstract Syntax Names shall be defined in the Service Class Definitions specified in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>. Each Abstract Syntax Name defined shall have a value of either</para>
<itemizedlist>
  <listitem>
<para xml:id="para_d7f405ac-ddd9-40c7-9b60-916efdac8278">a Service-Object Pair Class UID</para>
</listitem>
  <listitem>
<para xml:id="para_52e7bb2e-158d-4eb9-a88a-f41a67967ffd">a Meta Service-Object Pair Group UID</para>
</listitem>
</itemizedlist>
  <section label="D.1.1" status="3" xml:id="sect_D.1.1">
    <title>Service-Object Pair Class UID</title>
  
  <para xml:id="para_1ae8e229-8a8f-4ec5-8200-5cb5870a953f">Each Service Class Definition defines one or more functionally-related Service-Object Pair (SOP) Class definitions that specify well-defined operations and/or notifications that may be performed between peer DICOM Application Entities to provide an application-level service. Each SOP Class, identified by a SOP Class UID, is defined by the union of one Information Object Definition (IOD) and a specific set of one or more DIMSE Services called the DIMSE Service Group (DSG) in that</para>
<itemizedlist>
  <listitem>
<para xml:id="para_441291da-5247-4054-855d-7a48b7979ac6">The IOD defines the data structures</para>
</listitem>
  <listitem>
<para xml:id="para_7265cb97-432d-401a-8d42-97f4a80a990a">The DSG defines the operations and/or notifications that can be performed on this data structure.</para>
</listitem>
</itemizedlist>
    <para xml:id="para_a4915ae9-d871-474c-b5e9-8722997eb9b6">Two SOP Classes defined by a single Service Class Definition may differ by the IOD, the DSG or both. Two different IODs shall not, however, be part of the same SOP Class. <xref linkend="figure_D.1-1" xrefstyle="select: label"/> shows the relationships between Service Classes, IODs, DSGs and SOP Classes.</para>
  <para xml:id="para_347e01f0-a185-4070-b7ae-bd938f7d6698">
  <figure label="D.1-1" pgwide="1" xml:id="figure_D.1-1">
    <title>Service Class, IOD, DSG and SOP Class Relationships</title>
    <mediaobject>
      <imageobject>
        <imagedata fileref="figures/PS3.7_D.1-1.svg"/>
       <!--<imagedata fileref="part07_fromword_files/image014.png"/>-->
      </imageobject>
    </mediaobject>
  </figure>
</para>
  <note>
    <orderedlist>
      <listitem>
        <para xml:id="para_5c70a0e8-1905-4e1d-b69c-156ab5b1bdb2">Two examples of Service Classes are the Storage and Study Management Service Classes. The Storage Service Class relates to image Information Object Definitions such as CT, MR etc. and the Study Management Service Class relates to the Study Information Object Definition.</para>
      </listitem>
      <listitem>
        <para xml:id="para_50041eec-6fd1-4a0c-b765-8a9fe8eca36e">For readers familiar with OSI terminology, the concept of the Managed Object Class is the equivalent to the DICOM Service-Object Pair Class. The SOP Class specifies both the data (Attributes defined in the Information Object Definition) and the methods (Operations and Notifications (DSG) defined in the Service Class).</para>
      </listitem>
    </orderedlist>
  </note>
  <para xml:id="para_b44a69f9-cc12-4022-acbf-9612f1585e06">By setting the Abstract Syntax Name to a specific SOP Class UID value, DICOM Application Entities may negotiate Service Class operations and/or notifications for each defined SOP Class individually.</para>
  </section>
<section label="D.1.2" status="3" xml:id="sect_D.1.2">
    <title>Meta Service-Object Pair Group UID</title>
  
  <para xml:id="para_84f7c7c3-9c9d-4006-a2e1-77a4d9075d6e">Each Service Class Definition may optionally define one or more Meta Service-Object Pair Classes each being identified by a Meta SOP Class UID. Each Meta SOP Class represents the union of a set of SOP Classes defined in the Service Class.</para>
  <para xml:id="para_de9dbfe6-2c2d-4d47-8c90-4769cbcafa31">By setting the Abstract Syntax Name to a specific Meta SOP Class UID value, DICOM Application Entities may negotiate Service Class operations and/or notifications for a set of defined SOP Classes using a single Abstract Syntax. <xref linkend="figure_D.1-2" xrefstyle="select: label"/> depicts this.</para>
  <para xml:id="para_72d1a73c-4ed8-4491-be7f-42bed2542703">
<figure label="D.1-2" pgwide="1" xml:id="figure_D.1-2">
<title>SOP Class UIDs and Meta SOP Class UIDs and Abstract Syntax Names</title>
<mediaobject>
<imageobject>
<imagedata fileref="figures/PS3.7_D.1-2.svg"/>
<!--<imagedata fileref="part07_fromword_files/image016.png"/>-->
</imageobject>
</mediaobject>
</figure>
</para>
  </section>
</section>
<section label="D.2" status="2" xml:id="sect_D.2">
    <title>Transfer Syntaxes</title>
  
  <para xml:id="para_77628325-4988-4645-88e7-975055a23089">Transfer Syntaxes define a set of encoding rules used to unambiguously represent one or more Abstract Syntaxes. It allows communicating DICOM AEs to negotiate the encoding techniques they are able to support (e.g., byte ordering, compression, etc.).</para>
  </section>
<section label="D.3" status="2" xml:id="sect_D.3">
    <title>Association Establishment</title>
  
  <para xml:id="para_4c7642aa-cb7a-41ab-a731-d0203f9579d5">Association establishment is used to negotiate the type of data to be exchanged and how the data will be encoded. DICOM AEs establish Associations by using the ACSE A-ASSOCIATE Service as defined by Part 8 of the DICOM Standard. Three key parameters conveyed in the A-ASSOCIATE Service are the Application Context, Presentation Context, and the User Information Items. The following section discusses these negotiation parameters.</para>
  <para xml:id="para_e8d3f5bf-f84d-4e1e-b5a3-bb6cbd8bd0b0">Note: The A-ASSOCIATE Service is performed only once at Association established time. The examples shown in this Section separate the negotiation parameters for clarification purposes only. Readers should remember that only one A-ASSOCIATE request is offered for each Association and it contains all of the negotiation parameters.</para>
  <section label="D.3.1" status="3" xml:id="sect_D.3.1">
    <title>Application Context</title>
  
  <para xml:id="para_09b9bc10-a70b-45f5-8f21-181e44503596">An Application Context explicitly defines the set of Application Service Elements, related options and any other information necessary for the inter-working of DICOM AEs on an Association.</para>
  <para xml:id="para_74971a5c-069d-4d17-9f26-72431b67909e">The Application Context provides the highest level of negotiation, therefore, a very high level definition. Only one Application Context shall be offered per Association. DICOM specifies a single Application Context Name that defines the DICOM Application Context (applicable for this Standard and potentially later versions).</para>
  <note>
    <para xml:id="para_bbb29c3d-3811-4912-8ab7-a39dcb2eea48">For complete specification see <xref linkend="chapter_A" xrefstyle="template:Annex %n"/>.</para>
  </note>
  </section>
<section label="D.3.2" status="3" xml:id="sect_D.3.2">
    <title>Presentation Contexts Negotiation</title>
  
  <para xml:id="para_8c9ff88d-a779-4c55-bcfe-d1eb8851b09f">A Presentation Context defines the presentation of the data on an Association. It provides a lower level of negotiation and one or more Presentation Contexts can be offered and accepted per Association.</para>
  <para xml:id="para_cab30c07-76b2-42f7-84df-12bdebac63b9">A Presentation Context consists of three components, a Presentation Context ID, an Abstract Syntax Name, and a list of one or more Transfer Syntax Names.</para>
  <para xml:id="para_e5fe359c-8227-4643-ae65-f870041f81df">Only one Abstract Syntax shall be offered per Presentation Context. However, multiple Transfer Syntaxes may be offered per Presentation Context, but only one shall be accepted.</para>
  <para xml:id="para_819e4fab-7817-4b50-875f-b343af1e3c3a">For each SOP Class or Meta SOP Class a Presentation Context must be negotiated such that this Presentation Context supports the associated Abstract Syntax and a suitable Transfer Syntax. Presentation Contexts will be identified within the scope of a specific Association by a Presentation Context ID.</para>
  <para xml:id="para_7bf6da4d-605a-4731-8ff0-e2c747ee5510">
<xref linkend="figure_D.3-1" xrefstyle="select: label"/> provides an illustration of Presentation Context Negotiation with the key points as follows:</para>
  <orderedlist numeration="loweralpha">
<listitem>
<para xml:id="para_906d97aa-10e2-4bc1-a880-3900ae0719b2">the Association-requestor may offer multiple Presentation Contexts per Association.</para>
</listitem>
<listitem>
<para xml:id="para_c8e6a72d-5d48-4b1d-a1fc-05f7f31a2d61">each Presentation Context supports one Abstract Syntax (related to a SOP Class or Meta SOP Class) and one or more Transfer Syntaxes.</para>
</listitem>
<listitem>
<para xml:id="para_b556c769-65c9-411c-8626-cc9bac99e481">the Association-acceptor may accept or reject each Presentation Context individually.</para>
</listitem>
<listitem>
<para xml:id="para_efbdd4a0-4190-4d4d-b95a-4af508610e21">the Association-acceptor selects a suitable Transfer Syntax for each Presentation Context accepted.</para>
</listitem>
</orderedlist>
  <para xml:id="para_67ccf832-1050-4c1b-a9b3-b600e9efa457">
  <figure label="D.3-1" pgwide="1" xml:id="figure_D.3-1">
    <title>Presentation Contexts Negotiation</title>
    <mediaobject>
      <imageobject>
        <imagedata fileref="figures/PS3.7_D.3-1.svg"/>
       <!--<imagedata fileref="part07_fromword_files/image018.png"/>-->
      </imageobject>
    </mediaobject>
  </figure>
</para>
  </section>
<section label="D.3.3" status="3" xml:id="sect_D.3.3">
    <title>DICOM Application Association Information</title>
  
  <para xml:id="para_8b43863a-f801-442d-9621-d9c6a0f34571">Peer DICOM AEs negotiate, at Association establishment, a number of features related to the DIMSE protocol by using the ACSE User Information Item of the A-ASSOCIATE request. This Section discusses these features.</para>
  <para xml:id="para_f0e78cd6-302a-4138-8275-27174d00b854">When the Association is established between peer DIMSE Service Users the Kernel Functional Unit shall be assumed; therefore, the Kernel Functional Unit shall not be included in the A-ASSOCIATE User Information item.</para>
  <section label="D.3.3.1" status="4" xml:id="sect_D.3.3.1">
    <title>Maximum Length Application PDU Notification</title>
  
  <para xml:id="para_c2249232-92cd-48ed-a3fb-7844abf42ba0">The Maximum Length notification allows communicating AEs to limit the size of the data for each P-DATA indication. Each DICOM AE defines the maximum PDU size it can receive on this Association. Therefore, different maximum lengths can be specified for each direction of data flow on an Association. This notification is required. <xref linkend="figure_D.3-2" xrefstyle="select: label"/> illustrates the Maximum Length notification.</para>
  <note>
    <para xml:id="para_ed381be5-fca5-4f45-9a75-b8af0e31b0bc">For complete specification see <olink targetdoc="PS3.8" targetptr="PS3.8" xrefstyle="select: labelnumber"/>.</para>
  </note>
  <para xml:id="para_d43c4c5f-2dd7-4481-b349-1f2ea935cbbc">
<figure label="D.3-2" pgwide="1" xml:id="figure_D.3-2">
<title>Maximum Length PDU Negotiation</title>
<mediaobject>
<imageobject>
<imagedata fileref="figures/PS3.7_D.3-2.svg"/>
<!--<imagedata fileref="part07_fromword_files/image020.png"/>-->
</imageobject>
</mediaobject>
</figure>
</para>
  </section>
<section label="D.3.3.2" status="4" xml:id="sect_D.3.3.2">
    <title>Implementation Identification Notification</title>
  <para xml:id="para_6250c484-5e61-4f7f-ac0c-64e3689c2df0">The implementation identification notification allows implementations of communicating AEs to identify each other at Association establishment time. It is intended to provide respective (each network node knows the other's implementation identity) and non-ambiguous identification in the event of communication problems encountered between two nodes. This negotiation is required.</para>
  <para xml:id="para_42753b17-f6e9-4a84-bc3d-bb76e03a0fe0">Implementation identification relies on two pieces of information:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_ea70dd5d-c3ee-4b99-ba80-b3ab652b77bd">Implementation Class UID (required)</para>
</listitem>
  <listitem>
<para xml:id="para_5596f90e-bc03-4f92-8792-58836dc498ea">Implementation Version Name (optional)</para>
</listitem>
</itemizedlist>
  <para xml:id="para_be0cd668-569d-4abc-91a5-c8633663dd59">The Implementation Class UID identifies in a unique manner a specific class of implementation. Each node claiming Conformance to this Standard shall be assigned an Implementation Class UID to distinguish its implementation environment from others. Such Implementation Class UIDs shall be registered by the implementing organization per the policies defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>. This Standard does not specify the policies associated with assigning such a UID.</para>
  <para xml:id="para_a8cb0898-8d23-45d3-ac79-a3fc688d6fbd">Different equipment of the same type or product line (but having different serial numbers) shall use the same Implementation Class UID if they share the same implementation environment (i.e., software).</para>
  <para xml:id="para_0417dfb7-e39f-4bbe-90c3-3ed56ce7340a">The notification by Association requestors and acceptors of their respective Implementation Class UID is required for all implementations conforming to this Standard. <xref linkend="figure_D.3-3" xrefstyle="select: label"/> illustrates the Implementation Class UID notification.</para>
  <para xml:id="para_967849e6-4745-49d9-81a2-c1bf98d38f4a">
<figure label="D.3-3" pgwide="1" xml:id="figure_D.3-3">
<title>Implementation Class UID Notification</title>
<mediaobject>
<imageobject>
<imagedata fileref="figures/PS3.7_D.3-3.svg"/>
<!--<imagedata fileref="part07_fromword_files/image022.png"/>-->
</imageobject>
</mediaobject>
</figure>
</para>
  <para xml:id="para_b06d3960-d108-4e29-8b9b-bfd86fa90211">In addition to the Implementation Class UID, an option is provided to convey an Implementation Version Name of up to 16 characters,
      which identifies a version of an implementation for an Implementation Class UID.
      <xref linkend="figure_D.3-4" xrefstyle="select: label"/> illustrates the Implementation Version Name notification.
      This Standard does not specify the structure and policies associated with such an Implementation Version Name.
      The absence of the Implementation Version Name requires that the use of the same Implementation Class UID by two nodes guarantees that these use the same version of implementation.</para>
  <note>
      <orderedlist>
          <listitem>
              <para xml:id="para_e71f5d8f-0b7f-4f3a-9c2e-7ed0c9028da8">As the UID shall not be parsed (their structure is not intended to convey any semantic significance beyond uniqueness), this optional Implementation Version Name provides an adequate mechanism to distinguish two versions of the same implementation (same Implementation Class UID).</para>
          </listitem>
          <listitem>
              <para xml:id="para_3caa1ef1-d0bd-46a8-b4ea-d35c2deb215c">It is expected that if the Implementation Version Name is present, it will will include version information in addition to the name of the implementation.
                  The Implementation Version Name is expected to be more specific than the Implementation Class UID, and not less;
                  i.e., the Implementation Version Name will not have the same value when there are different values of the Implementation Class UID.</para>
          </listitem>
      </orderedlist>
  </note>
  <section label="D.3.3.2.1" status="5" xml:id="sect_D.3.3.2.1">
    <title>Implementation Class UID Sub-Item Structure (A-ASSOCIATE-RQ)</title>
  
  <para xml:id="para_256e1ffd-961b-4b4c-905b-5ec55f0d7ca0">The Implementation Class UID Sub-Item shall be made of a sequence of mandatory fixed length fields followed by a variable field. Only one Implementation Class UID Sub-Item shall be present in the User Data Item of the A-ASSOCIATE-RQ. <xref linkend="table_D.3-1" xrefstyle="select: label"/> shows the sequence of the mandatory fields.</para>
  <para xml:id="para_25ea1f90-e547-4d6a-b519-42e5224fe17e">
<figure label="D.3-4" pgwide="1" xml:id="figure_D.3-4">
<title>Implementation Version Name Notification</title>
<mediaobject>
<imageobject>
<imagedata fileref="figures/PS3.7_D.3-4.svg"/>
<!--<imagedata fileref="part07_fromword_files/image024.png"/>-->
</imageobject>
</mediaobject>
</figure>
</para>
    <table frame="box" label="D.3-1" rules="all" xml:id="table_D.3-1">
    <caption>Implementation Class UID Sub-Item Fields (A-ASSOCIATE-RQ)</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_19cfe3f5-edfd-4aca-93e9-783ac1148473">
          <emphasis role="bold">Item Bytes</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_13b9c265-faa5-478f-82f7-78f6889c2f3e">
          <emphasis role="bold">Field Name</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_c01e9d8c-a9d0-4a6f-92cb-481ce9759a07">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7079a8be-708d-4464-a047-abbc91832459">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_24a64e64-d850-47fd-9b78-1efe2195e07f">Item-type</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_30e65fc0-fdc4-4e66-9bb5-eace730d50d4">52H</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_dc76fdd6-5b25-4b77-944b-839d167bea8d">2</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5a8a2946-7add-4a67-8f42-a4d5b83af697">Reserved</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_81434078-e8a1-42e0-8f1b-889961a424f2">This reserved field shall be sent with a value 00H but not tested to this value when received.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_96293b78-0e23-43a1-a801-9bf345e46d24">3-4</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9786cfe5-964d-4e1a-ab05-9eff1efeaf0e">Item-length</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3b419c1b-2005-41c7-bc69-6403bca12022">This Item-length shall be the number of bytes from the first byte of the following field to the last byte of the Implementation-class-uid field. It shall be encoded as an unsigned binary number.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e70e160c-dbaf-452d-8dd3-f3910d036200">5-xxx</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_de73b646-b331-4923-b426-a27792d445f7">Implementation-class-uid</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_8755f80e-976f-4f72-b17b-7bc957bd18e8">This variable field shall contain the Implementation-class-uid of the Association-requestor as defined in <xref linkend="sect_D.3.3.2" xrefstyle="select: label"/>. The Implementation-class-uid field is structured as a UID as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>.</para>
      </td>
    </tr>
    </tbody>
  </table>
  </section>
<section label="D.3.3.2.2" status="5" xml:id="sect_D.3.3.2.2">
    <title>Implementation Class UID Sub-Item Structure (A-ASSOCIATE-AC)</title>
  
  <para xml:id="para_5740ae9c-e451-417e-be16-c0e57eba0ccf">The Implementation Class UID Sub-Item shall be made of a sequence of mandatory fixed length fields followed by a variable field. Only one Implementation Class UID Sub-Item shall be present in the User Data Item of the A-ASSOCIATE-AC. <xref linkend="table_D.3-2" xrefstyle="select: label"/> shows the sequence of the mandatory fields.</para>
    <table frame="box" label="D.3-2" rules="all" xml:id="table_D.3-2">
    <caption>Implementation UID Sub-Item Fields (A-ASSOCIATE-AC)</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_766cc5e2-c57d-461e-b0df-2c6c37256576">
          <emphasis role="bold">Item Bytes</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_bb0c633d-2ecc-4f0d-a4a9-35b76a015243">
          <emphasis role="bold">Field Name</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_cb3d5524-456f-4e90-8054-f81c852cd76e">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c32ae3a0-c2bc-45e9-90c5-aa91cc554889">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_92d8005e-c250-4e1e-a089-49a7ea831b31">Item-type</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_ba20eb7c-bd09-48b9-b049-d5b7ce270bc4">52H</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_687ff6e0-b7c8-4d83-b5af-01657f90d917">2</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_00c73f37-9a6b-4243-9d95-e9b21e3a4bd4">Reserved</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_59ebb730-9437-48e8-8fb2-3af20a8a2e49">This reserved field shall be sent with a value 00H but not tested to this value when received.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2f76f2fc-1587-4cc0-ad5b-ffd1532515c7">3-4</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_559da400-bd4e-4195-9748-47321000b05a">Item-length</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_35f05f89-a295-4160-a62d-d345142c38c9">This Item-length shall be the number of bytes from the first byte of the following field to the last byte of the Implementation-class-uid field. It shall be encoded as an unsigned binary number.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_24c91acd-c87d-46b6-8a67-24a7664331d8">5-xxx</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_fae041bc-8a0d-46f1-897b-b22f362ff9d9">Implementation-class-uid</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b52ade42-7bad-43a3-85e7-906fcbf5bfc6">This variable field shall contain the Implementation-class-uid of the Association-acceptor as defined in <xref linkend="sect_D.3.3.2" xrefstyle="select: label"/>. The Implementation-class-uid field is structured as a UID as defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>.</para>
      </td>
    </tr>
    </tbody>
  </table>
  </section>
<section label="D.3.3.2.3" status="5" xml:id="sect_D.3.3.2.3">
    <title>Implementation Version Name Structure (A-ASSOCIATE-RQ)</title>
  
  <para xml:id="para_fccc37e7-1699-4f2f-a157-e396ccef5aa6">The Implementation Version Name Sub-Item shall be made of a sequence of mandatory fixed length fields followed by a variable field. Only one Implementation Version Name Sub-Item shall be present in the User Data Item of the A-ASSOCIATE-RQ. <xref linkend="table_D.3-3" xrefstyle="select: label"/> shows the sequence of the mandatory fields.</para>
    <table frame="box" label="D.3-3" rules="all" xml:id="table_D.3-3">
    <caption>Implementation Version Name Sub-Item Fields (A-ASSOCIATE-RQ)</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_b5bd9b57-ffe3-4e07-b2f6-62ad22efe40b">
          <emphasis role="bold">Item Bytes</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_d2c1fbea-ab62-47f0-b37e-ef96874de615">
          <emphasis role="bold">Field Name</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_f8af5742-3133-4deb-9f5a-40b3bf41de75">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_88c4cbbe-5b06-4125-83e2-968e06ce68ed">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_45b21112-fb33-4d42-af92-dc00ba7f78c7">Item-type</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d2ac293f-46ae-4b4f-a25e-a9e8ebc1a9d0">55H</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_83490f64-ef77-4f2d-b5c6-2e135d01ae13">2</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3557c9a5-cd5a-4f65-9d21-ddb3e0cfb0c0">Reserved</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_75b2c8f7-4475-4f4a-944c-f7a89b7c60fe">This reserved field shall be sent with a value 00H but not tested to this value when received.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8b57661b-68c0-4b0f-b5d5-2ad5009cfaac">3-4</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_dddde33a-6bc7-44c8-9c98-a6267fdd4781">Item-length</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1a3e4036-c70a-48bd-992e-4f7432f6940e">This Item-length shall be the number of bytes from the first byte of the following field to the last byte of the Implementation-version-name field. It shall be encoded as an unsigned binary number.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d52001da-f223-4e74-8c04-581539afd52b">5-xxx</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0d131830-16d8-4329-9144-4139e0134673">Implementation-version-name</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_365c39f2-50c6-4f79-99ca-57e0df543fe6">This variable field shall contain the Implementation-version-name of the Association-requestor as defined in <xref linkend="sect_D.3.3.2" xrefstyle="select: label"/>. It shall be encoded as a string of 1 to 16 ISO 646:1990 (basic G0 set) characters.</para>
      </td>
    </tr>
    </tbody>
  </table>
  </section>
<section label="D.3.3.2.4" status="5" xml:id="sect_D.3.3.2.4">
    <title>Implementation Version Name Structure (A-ASSOCIATE-AC)</title>
  
  <para xml:id="para_670cb0ee-363f-4cf3-93cc-57567af68517">The Implementation Version Name Sub-Item shall be made of a sequence of mandatory fixed length fields followed by a variable field. Only one Implementation Version Name Sub-Item shall be present in the User Data Item of the A-ASSOCIATE-AC. <xref linkend="table_D.3-4" xrefstyle="select: label"/> shows the sequence of the mandatory fields.</para>
    <table frame="box" label="D.3-4" rules="all" xml:id="table_D.3-4">
    <caption>Implementation Version Name Sub-Item Fields (A-ASSOCIATE-AC)</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_22ab14e3-b504-4adc-9b26-c7e2904b6b13">
          <emphasis role="bold">Item Bytes</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_bec67f92-d1ce-436a-be83-330c8d5df3f9">
          <emphasis role="bold">Field Name</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_7da2505a-9e17-42ec-aae9-60eccabdf585">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6033058a-bf7c-4547-80c6-61de2fdffaf6">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c6435e36-a415-466c-ac9f-334700d8bcba">Item-type</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3090ad4e-9217-4f84-bb9f-b12f9b4f8c3c">55H</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_22febfdc-272c-4266-9098-8efa28ac846b">2</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9ca6743b-d92e-4c2b-97cc-35ac3a0b8aa0">Reserved</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_49f91379-cd10-4c13-a667-93fa7e25fc52">This reserved field shall be sent with a value 00H but not tested to this value when received.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_45b8b71a-b785-41b7-82b7-b1192d826b7c">3-4</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_83cb6b91-2838-451d-b24c-3a0b89cefba1">Item-length</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6c469f40-d7be-411b-941b-45644825c727">This Item-length shall be the number of bytes from the first byte of the following field to the last byte of the Implementation-version-name field. It shall be encoded as an unsigned binary number.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_866b3a53-16d9-4e68-a5d5-40dd82f9bbec">5-xxx</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1c8c5a54-1c72-416c-99eb-bb96894d0ad9">Implementation-version-name</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9a168741-56dd-4111-bf2b-546eb22273fa">This variable field shall contain the Implementation-version-name of the Association-acceptor as defined in <xref linkend="sect_D.3.3.2" xrefstyle="select: label"/>. It shall be encoded as a string of 1 to 16 ISO 646:1990 (basic G0 set) characters.</para>
      </td>
    </tr>
    </tbody>
  </table>
  </section>
</section>
<section label="D.3.3.3" status="4" xml:id="sect_D.3.3.3">
    <title>Asynchronous Operations (And Sub-Operations) Window Negotiation</title>
  
  <para xml:id="para_f5c2eda1-19b4-4574-8c81-e1ad78efbf1a">The Asynchronous Operations Window is used to negotiate the maximum number of outstanding operation or sub-operation requests (i.e., command requests) for each direction. The synchronous operations mode is the default mode and shall be supported by all DICOM AEs. This negotiation is optional.</para>
  <para xml:id="para_0d523164-c3de-45b4-b8f4-8f09cf7dca68">The Association-requestor conveys in the A-ASSOCIATE request:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_3fa86715-9353-40df-80ee-9230d225f0f4">when negotiating the SCU role for operations, the maximum number of outstanding operations it may invoke asynchronously; when negotiating the SCP role for operations, the maximum number of outstanding sub-operations it may invoke asynchronously; when negotiating the SCP role for notifications, the maximum number of notifications it may invoke asynchronously</para>
</listitem>
  <listitem>
<para xml:id="para_d55385a4-c5d9-4544-8c4b-ef4a3eb37ba5">when negotiating the SCP role for operations, the maximum number of outstanding operations it may invoke asynchronously; when negotiating the SCU role for operations, the maximum number of outstanding sub-operations it may perform asynchronously; when negotiating the SCU role for notifications, the maximum number of notifications it may perform asynchronously when negotiating the SCP role</para>
</listitem>
</itemizedlist>
  <para xml:id="para_c8dbc17e-73af-4244-9052-79eb101e9c36">A value of zero indicates that the above parameters are unlimited.
      A value of one indicates that there is no Asynchronous Operations support.
      If the Asynchronous Operations Window is absent the default for the above parameters shall be equal to one.</para>
  <para xml:id="para_a1bee3e4-adaf-45e9-912b-c94b3ba453f2">The Association-acceptor conveys in the A-ASSOCIATE response:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_517295fc-18cb-4e69-a11f-dd3d2353f3bd">when negotiating the SCP role for operations, the maximum number of outstanding operations; when negotiating the SCU role for operations, the maximum number of sub-operations it allows the Association-requestor to invoke asynchronously; when negotiating the SCU role for notifications, the maximum number of outstanding notifications it allows the Association-requestor to invoke asynchronously when negotiating the SCU role. This number shall be equal or less than the number of outstanding notifications, operations and/or sub-operations the Association-requestor offers to invoke (by the A-ASSOCIATE indication).</para>
</listitem>
  <listitem>
<para xml:id="para_fa94c939-ba09-4e2f-ac61-230fc3dd4355">when negotiating the SCU role for operations, the maximum number of outstanding operations; when negotiating the SCP role for operations, the maximum number of sub-operations it allows the Association-requestor to perform asynchronously; when negotiating the SCP role for notifications, the maximum number of outstanding notifications it allows the Association-requestor to perform asynchronously. This number shall be equal or less than the number of outstanding notifications, operations and/or sub-operations the Association-requestor offers to perform (by the A-ASSOCIATE indication).</para>
</listitem>
</itemizedlist>
  <para xml:id="para_c2b260ec-b0c5-447d-9957-ac82ccb34bf4">A value of zero indicates that the above parameters are unlimited. If the Asynchronous Operations Window is absent the default for the above parameters shall be equal to one. Figures D.3-5 and D.3-6 illustrate examples of Asynchronous Operations Window negotiation.</para>
  <para xml:id="para_6dc8d08d-2763-4c45-a743-32b2a8a5bab9">If this negotiation is not present in the A-ASSOCIATE indication it shall be omitted in the A-ASSOCIATE response.</para>
  <note>
    <para xml:id="para_1eae59f1-14f6-4849-af72-2c070e3bfa59">The case where the Association-requestor offers the value of zero (which indicates unlimited operations), the Association-acceptor may return zero (agreeing to unlimited operations) or negotiate the parameter down by conveying a value other than zero.</para>
  </note>
  <para xml:id="para_1171c173-4014-4c0d-adbe-1435203cf4ee">
<figure label="D.3-5" pgwide="1" xml:id="figure_D.3-5">
<title>Asynchronous Operations Window Negotiation (Window Being Negotiated Down By DICOM Application Entity "B")</title>
<mediaobject>
<imageobject>
<imagedata fileref="figures/PS3.7_D.3-5.svg"/>
<!--<imagedata fileref="part07_fromword_files/image026.png"/>-->
</imageobject>
</mediaobject>
</figure>
</para>
  <para xml:id="para_514e9a83-8cd1-4a1d-9661-0ff903471a39">
<figure label="D.3-6" pgwide="1" xml:id="figure_D.3-6">
<title>Asynchronous Operations Window Negotiation (Window Being Defaulted to 1, 1 By DICOM Application Entity "B")</title>
<mediaobject>
<imageobject>
<imagedata fileref="figures/PS3.7_D.3-6.svg"/>
<!--<imagedata fileref="part07_fromword_files/image028.png"/>-->
</imageobject>
</mediaobject>
</figure>
</para>
  <section label="D.3.3.3.1" status="5" xml:id="sect_D.3.3.3.1">
    <title>Asynchronous Operations Window Sub-Item Structure (A-ASSOCIATE-RQ)</title>
  
  <para xml:id="para_78b94334-53e6-4c58-a0db-7aede92622b4">The Asynchronous Operations Window Sub-Item shall be made of a sequence of mandatory fixed length fields. This Sub-Item is optional and if supported, only one Asynchronous Operations Window Sub-Item shall be present in the User Data Item of the A-ASSOCIATE-RQ. <xref linkend="table_D.3-7" xrefstyle="select: label"/> shows the sequence of the mandatory fields.</para>
    <table frame="box" label="D.3-7" rules="all" xml:id="table_D.3-7">
    <caption>Asynchronous Operations Window Sub-Item Fields (A-ASSOCIATE-RQ)</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_1855c251-c19d-4b7b-8559-b8aafdca8650">
          <emphasis role="bold">Item Bytes</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_73b674f2-2ba6-4cb0-bed8-a466e63e6815">
          <emphasis role="bold">Field Name</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_acc35c8a-8ee4-452a-9f5c-268aadd2ab8b">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8f6a9237-a6bf-4a55-9957-907166f93664">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_552d7807-8305-40ed-9697-857c77d6a5f2">Item-type</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_8d9ffcbc-0850-46ff-b976-597a05872e0f">53H</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_66eaf02a-367b-4431-aa00-8f9de85230d6">2</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_94148972-3f82-4332-bd1a-a506d5646d8a">Reserved</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_8779ef8f-c786-48d3-b0f3-b9217ab79fc6">This reserved field shall be sent with a value 00H but not tested to this value when received.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_af7c9a1f-ddf7-485d-919b-ae5c66db693a">3-4</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5b972829-32f9-40de-ab00-3c61a3d2a5a9">Item-length</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5370be8b-99d1-4657-a6b2-46e23d133160">This Item-length shall be the number of bytes from the first byte of the following field to the last byte of the Maximum-number-operations-performed field. In the case of this Sub-Item, it shall have the fixed value of 00000004H encoded as an unsigned binary number.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_aa670df5-b5e7-4f24-a34d-8186af264fba">5-6</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_15171cc3-84cd-41bf-a141-ae1c2be87715">Maximum-number-operations-invoked</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_2172db9c-445b-4310-a50e-ca10e37bdc1e">This field shall contain the Maximum-number-operations-invoked as defined for the Association-requestor in <xref linkend="sect_D.3.3.3" xrefstyle="select: label"/>. It shall be encoded as an unsigned binary number.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_204cef34-0479-4caa-a21e-c26c5448dfcc">7-8</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e713bfd9-1b23-499b-a5da-58c46fd4c8e1">Maximum-number-operations-performed</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_df3df07e-4003-43ea-85ea-6e226f4f209e">This field shall contain the Maximum-number-operations-performed as defined for the Association-requestor in <xref linkend="sect_D.3.3.3" xrefstyle="select: label"/>. It shall be encoded as an unsigned binary number.</para>
      </td>
    </tr>
    </tbody>
  </table>
  </section>
<section label="D.3.3.3.2" status="5" xml:id="sect_D.3.3.3.2">
    <title>Asynchronous Operations Window Sub-Item Structure (A-ASSOCIATE-AC)</title>
  
  <para xml:id="para_6b718189-c899-48da-8d08-b5b2ed50deef">The Asynchronous Operations Window Sub-Item shall be made of a sequence of mandatory fixed length fields. This Sub-Item is optional and if supported, only one Asynchronous Operations Window Sub-Item shall be present in the User Data Item of the A-ASSOCIATE-AC. <xref linkend="table_D.3-8" xrefstyle="select: label"/> shows the sequence of the mandatory fields.</para>
    <table frame="box" label="D.3-8" rules="all" xml:id="table_D.3-8">
    <caption>Asynchronous Operations Window Sub-Item Fields (A-ASSOCIATE-AC)</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_a982face-d37f-43eb-acff-bc966aebf281">
          <emphasis role="bold">Item Bytes</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_eba51b2f-d950-4ae5-8f6e-3d6549ce5970">
          <emphasis role="bold">Field Name</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_829c0ba2-bf4f-47bb-9177-b3d9c57416c0">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_69f85e03-c6ed-4cbf-832d-94a5d114f730">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_91f1f8d8-9193-48e0-b210-e1b44275a4bb">Item-type</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_69309a21-867b-4867-9ee8-929d92ca5a1a">53H</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_49daf7ab-b280-4a85-8e9b-8b2a785bb76d">2</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_7019f33b-c169-4c3b-8e67-84d0d0db79d1">Reserved</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_79ca7e64-dcef-4263-b1af-1d2e30653f02">This reserved field shall be sent with a value 00H but not tested to this value when received.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_bd93be07-6341-468a-9e38-509a0999b9f7">3-4</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_09ac443b-e0f5-4ea8-b6e3-7916b1dfd322">Item-length</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_408b9275-21a8-4f1e-bda4-c830441c73bd">This Item-length shall be the number of bytes from the first byte of the following field to the last byte of the Maximum-number-operations-performed field. In the case of this Sub-Item, it shall have the fixed value of 00000004H encoded as an unsigned binary number.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9ffbc4d5-6bfc-4be8-9672-a070f6d23330">5-6</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c7571ecf-f410-492a-ad78-8059d938029e">Maximum-number-operations-invoked</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b6f53ef1-ce83-486f-b98a-3627873ea108">This field shall contain the Maximum-number-operations-invoked as defined for the Association-acceptor in <xref linkend="sect_D.3.3.3" xrefstyle="select: label"/> It shall be encoded as an unsigned binary number.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c332ee15-6d2b-485b-b835-9d3ddb37e0a9">7-8</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_18f00636-2303-4a7a-84be-9e7d2f7fc883">Maximum-number-operations-performed</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b3b94934-daf8-4b87-89c9-f6983331a11a">This field shall contain the Maximum-number-operations-performed as defined for the Association-acceptor in <xref linkend="sect_D.3.3.3" xrefstyle="select: label"/>. It shall be encoded as an unsigned binary number.</para>
      </td>
    </tr>
   </tbody>
  </table>


  </section>
</section>
<section label="D.3.3.4" status="4" xml:id="sect_D.3.3.4">
    <title>SCP/SCU Role Selection Negotiation</title>
  
  <para xml:id="para_b557f018-3b8e-481b-98b2-1c3e7d8af750">The SCP/SCU Role Selection Negotiation allows peer AEs to negotiate the roles in which they will serve for each SOP Class or Meta SOP Class supported on the Association. This negotiation is optional.</para>
  <para xml:id="para_13a813d8-4463-4f40-9c6e-2b050415cc54">The Association-requestor, for each SOP Class UID or Meta SOP Class UID, may use one SCP/SCU Role Selection item. The SOP Class or Meta SOP Class shall be identified by its corresponding Abstract Syntax Name followed by one of the three role values:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_85ebcc95-6b8b-4bba-89b6-8f3cc8517db1">Association-requestor is SCU only</para>
</listitem>
  <listitem>
<para xml:id="para_7260706a-d509-40dd-9e97-e8f7293d217e">Association-requestor is SCP only</para>
</listitem>
  <listitem>
<para xml:id="para_761d216f-7704-4265-a695-041155f46a78">Association-requestor is both SCU and SCP</para>
</listitem>
</itemizedlist>
  <para xml:id="para_b7de055c-3e50-427e-ad0b-f69a6ac9fd40">If the SCP/SCU Role Selection item is absent the default role of the Association-requestor shall be SCU and the default role of the Association-acceptor shall be SCP.</para>
  <para xml:id="para_40cf24e8-2bff-4bb7-b1d0-df3bbb754804">The Association-acceptor, for each SCP/SCU Role Selection item offered, either accepts the Association-requestor proposal by returning the same value (1) or turns down the proposal by returning the value (0). The Association-acceptor shall not return the value (1) if the Association-requestor has not proposed the role, i.e., it has sent a value (0). The Association-requestor shall ignore the response if it has not proposed the role.</para>
  <para xml:id="para_3745c745-d4a1-4cde-8fb7-e39265a1c212">If the SCP/SCU Role Selection item is not returned by the Association-acceptor then the role of the Association-requestor shall be SCU and the role of the Association-acceptor shall be SCP. <xref linkend="figure_D.3-7" xrefstyle="select: label"/> illustrates the SCP/SCU Role Selection Negotiation.</para>
  <para xml:id="para_203f3f14-1a13-4e03-9923-a1e6e7ba065d">If the SCP/SCU Role Selection items do not exist in the A-ASSOCIATE indication they shall be omitted in the A-ASSOCIATE response.</para>
  <note>
    <orderedlist numeration="arabic">
      <listitem>
        <para xml:id="para_c8253ecd-389d-4a34-bcd8-36dc84a07fad">The choices made for the default roles are based on clarification made to previous versions of the Standard. Association-requestors that wish to offer Abstract Syntax Names using the SCP role must support this item. Association-acceptors that wish to accept Abstract Syntax Names using the SCU role must support this item.</para>
      </listitem>
      <listitem>
        <para xml:id="para_8ed7bad9-2b19-4b3a-855a-c2ec0b6ae329">If an Association-requestor offers an SCP/SCU Role Selection item for an Abstract Syntax Name but the Association-acceptor does not return an SCP/SCU Role Selection item for the same Abstract Syntax Name then the proposed roles have not been accepted and the default roles apply (i.e., Association-requestor is SCU and Association-acceptor is SCP).</para>
      </listitem>
    </orderedlist>
  </note>
  <para xml:id="para_72ae98b9-8a75-434c-a0b4-5f8eece54cad">
<figure label="D.3-7" pgwide="1" xml:id="figure_D.3-7">
    <title>SCU/SCP Role Selection Negotiation</title>
<mediaobject>
<imageobject>
<imagedata fileref="figures/PS3.7_D.3-7.svg"/>
<!--<imagedata fileref="part07_fromword_files/image030.png"/>-->
</imageobject>
</mediaobject>
</figure>
</para>
  <note>
    <orderedlist numeration="arabic">
      <listitem>
<para xml:id="para_b7ce6ec6-faff-410d-83a0-cd360db4d46e">DICOM AE "B" accepts DICOM AE "A"'s proposed role as an SCU for the Storage-MR SOP; therefore, DICOM AE "B" will perform in the SCP role. DICOM AE "B" turns down the SCP proposal from DICOM AE "A".</para>
      </listitem>
      <listitem>
<para xml:id="para_1cd1b08a-bd44-4306-9e8f-1a79f20c72a9">Both DICOM AEs may be SCU and SCP for the Storage-CT SOP.</para>
      </listitem>
      <listitem>
<para xml:id="para_64af5f51-1b81-4af5-913b-638d1dabaa81">DICOM AE "B" accepts DICOM AE "A"'s proposed role as an SCU for the Print-SOP; therefore, DICOM AE "B" will perform in the SCP role.</para>
      </listitem>
    </orderedlist>
  </note>
  <section label="D.3.3.4.1" status="5" xml:id="sect_D.3.3.4.1">
    <title>SCP/SCU Role Selection Sub-Item Structure (A-ASSOCIATE-RQ)</title>
  
  <para xml:id="para_fdf0743d-03b5-4604-a4a2-805d7e5743a3">The SCP/SCU Role Selection Sub-Item shall be made of a sequence of mandatory fields. This Sub-Item is optional and if supported, one or more SCP/SCU Role Selection Sub-Items may be present in the User Data Item of the A-ASSOCIATE-RQ. The Association-requestor may only offer one SOP Class SCP/SCU Role Selection Sub-Item for each SOP Class UID or Meta SOP Class that is present in the A-ASSOCIATE request. <xref linkend="table_D.3-9" xrefstyle="select: label"/> shows the sequence of the mandatory fields.</para>
    <table frame="box" label="D.3-9" rules="all" xml:id="table_D.3-9">
    <caption>SCP/SCU Role Selection Sub-Item Fields (A-ASSOCIATE-RQ)</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_046a742d-7a71-4ce0-98bc-2bf2321805aa">
          <emphasis role="bold">Item Bytes</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_e62d1e43-4cc9-473c-a625-7f3a220231ef">
          <emphasis role="bold">Field Name</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_1c761cc8-4716-4417-a3ee-c7fd2bced738">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_bd0ae0f2-218f-49fd-87d3-78873b303d72">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_03bbe1f0-8772-4872-837e-dac23f34a4b3">Item-type</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6b0ce6e4-22e6-4e9b-9ce1-a9c6bdc8ea1d">54H</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_539e1d27-c57f-4622-8272-a34a2e734aa1">2</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a6d48460-d5da-46b0-b0ec-5cd203fa8b5a">Reserved</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d932f65f-db20-48d3-a0b4-4c6c12c7d72a">This reserved field shall be sent with a value 00H but not tested to this value when received.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ae59a743-aabc-4630-8222-8d1f7af99fb9">3-4</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0ecf0e44-ade3-40bf-9414-b022484238d9">Item-length</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_dc8e4956-bfb3-4dde-9f8c-2d187bb2aed3">This Item-length shall be the number of bytes from the first byte of the following field to the last byte of the SCP Role field. It shall be encoded as an unsigned binary number.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_89f1d0f2-4ae1-4c10-9c0e-03b0b04b0ae2">5-6</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_171caf1a-dc01-4d8a-b9ab-d2e89c8019c5">UID-length</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_986979e2-ad58-4f3d-bba8-110a8a4cede0">This UID-length shall be the number of bytes from the first byte of the following field to the last byte of the SOP-class-uid field. It shall be encoded as an unsigned binary number.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_be9716ef-5c16-4122-8c06-3fdb70416dcf">7 -xxx</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c608f09a-00dd-46d0-905d-a228c5a0dce2">SOP-class-uid</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_97dba67d-c728-4745-9b91-aedb52d29550">This variable field shall contain the SOP Class UID or Meta SOP Class UID that may be used to identify the corresponding Abstract Syntax for which this Sub-Item pertains. It shall be encoded as a UID as defined in <olink targetdoc="PS3.5" targetptr="chapter_9" xrefstyle="template:Section %n “%t” in PS3.5"/>.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b31466aa-d6ea-4a5d-b580-f3664022fca1">xxx</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_29659ae2-8a4b-4b0b-8e7e-8429a8ae262d">SCU-role</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_26414a13-e956-45cd-8eca-40383c1d67c1">This byte field shall contain the SCU-role as defined for the Association-requestor in <xref linkend="sect_D.3.3.4" xrefstyle="select: label"/>. It shall be encoded as an unsigned binary and shall use one of the following values:</para>
        <para xml:id="para_ce83748c-077f-4bd8-9d26-fe35014dc5b3">0 - non support of the SCU role</para>
        <para xml:id="para_a3068a65-9e0a-4661-b0ff-e160cc451777">1 - support of the SCU role</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_519a9df1-e8fa-402e-a2ab-754b94ec33a3">xxx</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f25d4130-a412-4855-9ea8-f08903a4b3e2">SCP-role</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e76d909d-6b8f-46b9-b2c8-337a8439454b">This byte field shall contain the SCP-role as defined for the Association-requestor in <xref linkend="sect_D.3.3.4" xrefstyle="select: label"/>. It shall be encoded as an unsigned binary and shall use one of the following values:</para>
        <para xml:id="para_0784015d-0e01-4ead-b779-18d1f30cc956">0 - non support of the SCP role</para>
        <para xml:id="para_2e34636c-e932-4354-ae04-2ebe0260aa81">1 - support of the SCP role.</para>
      </td>
    </tr>
   </tbody>
  </table>


  </section>
<section label="D.3.3.4.2" status="5" xml:id="sect_D.3.3.4.2">
    <title>SCP/SCU Role Selection Sub-Item Structure (A-ASSOCIATE-AC)</title>
  
  <para xml:id="para_b803967c-fbb6-4991-ac35-423a372b3402">The SCP/SCU Role Selection Sub-Item shall be made of a sequence of mandatory fields. This Sub-Item is optional and if supported, one or more SCP/SCU Role Selection Sub-Items may be present in the User Data Item of the A-ASSOCIATE-AC. <xref linkend="table_D.3-10" xrefstyle="select: label"/> shows the sequence of the mandatory fields.</para>
    <table frame="box" label="D.3-10" rules="all" xml:id="table_D.3-10">
    <caption>SCP/SCU Role Selection Sub-Item Fields (A-ASSOCIATE-AC)</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_3938c23f-bc09-438a-a71f-1362affb2934">
          <emphasis role="bold">Item Bytes</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_e5ac7850-8fef-492f-a3fa-be2fa3d82842">
          <emphasis role="bold">Field Name</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_301b4a81-1341-47d4-9038-78fbc12ef99b">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d3e1ae2a-d617-4d25-a0d7-e4a1bcba2b06">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_75357e0c-8480-40d0-acd7-1a138c37fabd">Item-type</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_247ed18e-c5e1-45cb-91ba-c07653fc53d6">54H</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_59f7d0c0-04f1-43f5-944f-b219c32c90fe">2</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a8446110-8cb9-4f83-b381-4165ef4387c2">Reserved</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9c241ff4-f65a-4ff0-b20a-aa10d580c5eb">This reserved field shall be sent with a value 00H but not tested to this value when received.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b5aa5489-a654-4c4f-884e-bb9ce714f6bc">3-4</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3a995129-b81f-44ed-b3df-e08596c7438b">Item-length</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0b3f4fc8-078f-4b6b-b7a1-eaa904e9f654">This Item-length shall be the number of bytes from the first byte of the following field to the last byte of the SCP Role field. It shall be encoded as an unsigned binary number.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ba698302-37a9-4819-b9c4-f048888f4873">5-6</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_aef07b1e-2aa8-4e9c-a92b-c0ef7b1693bc">UID-length</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_028695ed-76a0-4cbf-98bc-b1a38f36e0c5">This UID-length shall be the number of bytes from the first byte of the following field to the last byte of the SOP-class-uid field. It shall be encoded as an unsigned binary number.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_62910964-46f9-424a-b906-40aa52d2c019">7-xxx</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f0efbdf1-fa4f-49f7-b81c-c578b7947a13">SOP-class-uid</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1ffd380b-9a03-4c96-bd6c-bcc2c3a29d8a">This variable field shall contain the SOP Class UID or Meta SOP Class UID that may be used to identify the corresponding Abstract Syntax for which this Sub-Item pertains. It shall be encoded as a UID as defined in <olink targetdoc="PS3.5" targetptr="chapter_9" xrefstyle="template:Section %n “%t” in PS3.5"/>.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0cc851b4-fcac-4dbd-9839-0f32c71fb949">xxx</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_fce3d914-0a31-410a-a7d1-135bb2b64102">SCU-role</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_65822dbd-89d8-4be3-9386-44547813e961">This byte field shall contain the SCU-role as defined in <xref linkend="sect_D.3.3.4" xrefstyle="select: label"/>. It shall be encoded as an unsigned binary and shall use one of the following values:</para>
        <para xml:id="para_adb8d2bd-7743-4b78-a1cb-dff23e013521">0 - The Association-acceptor rejects the Association-requestor's proposal of the SCU role selection</para>
        <para xml:id="para_eacbd064-f29c-405c-b3a5-e552a61be15c">1 - The Association-acceptor accepts the Association-requestor's proposal of the SCU role selection</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1f063b52-b71e-479a-a373-26d046b4613c">xxx</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_39afbcef-ceac-4c9d-b0d5-ddcd9aabd6ea">SCP-role</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_67451cde-f1c2-4a3f-a20e-1a7dda245ebf">This byte field shall contain the SCP-role as defined for the Association-acceptor in <xref linkend="sect_D.3.3.4" xrefstyle="select: label"/>. It shall be encoded as an unsigned binary and shall use one of the following values:</para>
        <para xml:id="para_7c4b6838-4e41-4e85-a3b1-47246dba060e">0 - The Association-acceptor rejects the Association-requestor's proposal of the SCP role selection</para>
        <para xml:id="para_9b48ad11-09f8-4db2-847b-52cbc03918db">1 - The Association-acceptor accepts the Association-requestor's proposal of the SCP role selection</para>
      </td>
    </tr>
   </tbody>
  </table>


  </section>
</section>
<section label="D.3.3.5" status="4" xml:id="sect_D.3.3.5">
    <title>Service-Object Pair (SOP) Class Extended Negotiation</title>
  
  <para xml:id="para_d7b0078e-e3d6-4e48-b472-1d4084889eac">The SOP Class Extended Negotiation allows, at Association establishment, peer DICOM AEs to exchange application information defined by specific Service Class specifications. This is an optional feature that various Service Classes may or may not choose to support.</para>
  <para xml:id="para_667f0bfd-e0ef-43a5-b213-aa3a72bfab54">Each Service Class specification is required to document, as part of its SOP Class or Meta SOP Class, the application information it supports and how this information is negotiated between SCUs and SCPs. Service Class specifications shall specify, for both the SCU and SCP roles, the following:</para>
<itemizedlist>
  <listitem>
<para xml:id="para_1e60196c-e65e-4ad5-b6d4-ab4772fb44fd">semantics of the application information (including the negotiation rules)</para>
</listitem>
  <listitem>
<para xml:id="para_25431786-b5b5-41cc-bb6b-b5da80ab28d2">encoding of the application information</para>
</listitem>
  <listitem>
<para xml:id="para_dbe018b8-1cee-4c0e-a9bf-9f9707c867fa">conditions for which the application information is mandatory and/or optional</para>
</listitem>
  <listitem>
<para xml:id="para_e347003c-1bbc-4376-a09b-681ebbb72325">default conditions of the application information</para>
</listitem>
</itemizedlist>
  <note>
    <para xml:id="para_3a13094c-f617-4958-a275-f1c849b804f9">The use of the SOP Class Extended Negotiation is not limited to Service Classes defined by this Standard. It may also be used for privately defined Service Classes.</para>
  </note>
  <para xml:id="para_3d0d0aec-0c16-45dc-97ee-f1a49f3f3c1a">The Association-requestor may only offer one SOP Class Extended Negotiation Sub-Item for each SOP Class UID or Meta SOP Class that is present in the A-ASSOCIATE request.</para>
  <para xml:id="para_f401f31e-34f0-46fb-83d1-4975d488ff15">If the SOP Class Extended Negotiation Sub-Items do not exist in the A-ASSOCIATE indication they shall be omitted in the A-ASSOCIATE response.</para>
  <section label="D.3.3.5.1" status="5" xml:id="sect_D.3.3.5.1">
    <title>SOP Class Extended Negotiation Sub-Item Structure (A-ASSOCIATE-RQ)</title>
  
  <para xml:id="para_b4b2a3ff-b867-46d3-a89f-cac960f09a7b">The SOP Class Extended Negotiation Sub-Item shall be made of a sequence of mandatory fields followed by the Service-class-application-information field (specific for each Service Class specification). This Sub-Item is required per the specific Service Class specifications. Multiple SOP Class Extended Negotiation Sub-Items may be present in the User Data Item of the A-ASSOCIATE-RQ, however, only one Sub-Item per SOP Class UID shall be present. <xref linkend="table_D.3-11" xrefstyle="select: label"/> shows the sequence of mandatory fields.</para>
    <table frame="box" label="D.3-11" rules="all" xml:id="table_D.3-11">
    <caption>SOP Class Extended Negotiation Sub-Item Fields (A-ASSOCIATE-RQ and A-ASSOCIATE-AC)</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_1412599c-ac1b-43f9-9804-61e55bd0d495">
          <emphasis role="bold">Item Bytes</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_18758c3b-fd6a-4bf5-badd-08f36b365df4">
          <emphasis role="bold">Field Name</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_ae42f77a-8f48-4389-b854-6fa51c6a95cd">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ced2acaf-0a22-47af-b107-92f9e53d7dc3">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1af1ef36-d48a-4f6b-a290-9629a918bca0">Item-type</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_99efd992-10e5-428b-9790-a0df1bc42ab9">56H</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1778aebf-be4d-4955-b523-cc33b43b630e">2</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f0e2bb86-e7ab-458a-846e-e262dd4f16ed">Reserved</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_abee2e98-5c30-4fdf-91bf-9db9d2220a34">This reserved field shall be sent with a value 00H but not tested to this value when received.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5216705b-23ee-460d-84b4-48e601be533d">3-4</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5c33ea9c-70f4-4425-bbcc-1082b7fa81fa">Item-Length</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_20413e4f-8f0c-462a-90c4-24b008ef7c2d">This Item-length shall be the number of bytes from the first byte of the following field to the last byte of the Service-class-application-information field. It shall be encoded as an unsigned binary number.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5e5d1795-88b2-4a3a-a79b-b907ea297b42">5-6</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_ee58c92a-1a26-4a84-b200-4d32a72d940f">SOP-class-uid-length</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e7b886e3-13bd-46f1-a1bd-691fa25f3ac2">The SOP-class-uid-length shall be the number of bytes from the first byte of the following field to the last byte of the SOP-class-uid field. It shall be encoded as an unsigned binary number.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a70241c9-54a4-4f5f-91c5-c3a426128c45">7-xxx</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_46041e4e-5439-4115-9f3f-bff0ccb31581">SOP-class-uid</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_80d0f1f3-bd27-4969-9d18-124d3e24366d">The SOP Class or Meta SOP Class identifier encoded as a UID as defined in <olink targetdoc="PS3.5" targetptr="chapter_9" xrefstyle="template:Section %n “%t” in PS3.5"/>.</para>
      </td>
    </tr>
    <tr valign="top">
        <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_3354e654-f1d6-4867-9180-f519b5162ac6">xxx-xxx</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_05c32409-57cc-4ff2-a613-caf143887ff9">Service-class-application-information</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_bdf326ea-b4f3-4d97-871d-672b5ddc22f8">This field shall contain the application information specific to the Service Class specification identified by the SOP-class-uid. The semantics and value of this field is defined in the identified Service Class specification.</para>
      </td>
    </tr>
   </tbody>
  </table>


  </section>
<section label="D.3.3.5.2" status="5" xml:id="sect_D.3.3.5.2">
    <title>SOP Class Extended Negotiation Sub-Item Structure (A-ASSOCIATE-AC)</title>
  
  <para xml:id="para_652ca81e-898c-4ca6-aacd-6126a5778084">The SOP Class Extended Negotiation Sub-Item shall be made of a sequence of mandatory fields followed by the Service-class-application-information field (specific for each Service Class specification). This Sub-Item is required per the specific Service Class specifications. Multiple SOP Class Extended Negotiation Sub-Items may be present in the User Data Item of the A-ASSOCIATE-AC, however, only one Sub-Item per SOP Class UID shall be present. <xref linkend="table_D.3-11" xrefstyle="select: label"/> shows the sequence of mandatory fields.</para>
  </section>
</section>
<section label="D.3.3.6" status="4" xml:id="sect_D.3.3.6">
    <title>Service-Object Pair (SOP) Class Common Extended Negotiation</title>
  
  <para xml:id="para_31aef017-4efe-427c-aed9-8e73d8e2adce">The SOP Class Common Extended Negotiation allows, at Association establishment, peer DICOM AEs to exchange application information, the form of which is generic, and not specific to individual Service Classes, as compared to the information defined in D.3.3.5. This is an optional feature that Association-requestors and Association-acceptors may or may not choose to support.</para>
  <para xml:id="para_1112a3d6-e978-4d89-ba35-29379a13ae8a">The information included for each SOP Class for which a sub-item is present consists of a Service Class UID and (optionally) a Related General SOP Class UID.</para>
  <para xml:id="para_e93d0c95-8354-4562-aadd-6d8915d628d0">The Service Class UID conveys the Service Class of the SOP Class.</para>
  <note>
    <para xml:id="para_83421938-ecf6-4697-9c1f-cff5479f199b">Explicit conveyance of the Service Class may allow the selection of the proper format for the Service-class-application-information of the SOP Class Extended Negotiation Sub-Item.</para>
  </note>
  <para xml:id="para_df79db08-d4d7-4b5f-94f6-df970268ae99">The Related General SOP Class UID conveys zero or more Related General SOP Class for the SOP Class.</para>
  <note>
    <orderedlist>
      <listitem>
        <para xml:id="para_bb3042a5-8bba-4839-913e-9a25292b34ea">Consider the example of negotiation of support for a Procedure Log Storage SOP Class. That SOP Class is of the Storage Service Class. The encoding of the IOD would be compatible with the more general Enhanced SR Storage SOP Class. Therefore, the following common Extended Negotiation sub-item could optionally be included:</para>
        <itemizedlist mark="none">
          <listitem>
<para xml:id="para_73d2309e-dbd7-4ba4-bece-6c515aaaaeae">SOP Class UID: 1.2.840.10008.5.1.4.1.1.88.40 Procedure Log</para>
</listitem>
          <listitem>
<para xml:id="para_75fcea33-0283-4907-83c5-c0d93bee36e4">Service Class UID: 1.2.840.10008.4.2 Storage Service Class</para>
</listitem>
          <listitem>
<para xml:id="para_f3603dd6-88b9-416b-988c-d83017e1265a">Related General SOP Class UID: 1.2.840.10008.5.1.4.1.1.88.22 Enhanced SR</para>
</listitem>
        </itemizedlist>
        
        
        
      </listitem>
      <listitem>
        <para xml:id="para_dcd404ab-f638-41c9-bbf3-2872529751b6">The Related SOP Class may be absent, though the Service Class may still be included. For example, there may be a new image storage SOP Class without a Related SOP Class defined in <olink targetdoc="PS3.4" targetptr="PS3.4" xrefstyle="select: labelnumber"/>, yet it is still useful to an Association-acceptor to be informed that the new SOP Class is of the Storage Service Class:</para>
        <itemizedlist mark="none">
          <listitem>
<para xml:id="para_f03a3c31-7aaa-439e-bbdd-84287eae7853">SOP Class UID: 1.2.840.10008.5.1.4.1.1.7.1 MF Single Bit SC Image Storage</para>
</listitem>
          <listitem>
<para xml:id="para_e0b5399a-41b7-4eff-b1da-4d1d1c6e84ae">Service Class UID: 1.2.840.10008.4.2 Storage Service Class</para>
</listitem>
          <listitem>
<para xml:id="para_d17913e6-d0b2-4646-8d2c-94a92d0e565f">Related General SOP Class UID: (none)</para>
</listitem>
        </itemizedlist>
        
        
        
      </listitem>
    </orderedlist>
  </note>
  <para xml:id="para_f4662e06-8779-4663-abb4-1cf8103deba1">The Association-requestor may only offer one SOP Class Common Extended Negotiation Sub-Item for each SOP Class UID that is present in the A-ASSOCIATE request.</para>
  <para xml:id="para_9ec8279a-4d21-424e-bd44-42e3a63dce41">No response is necessary, hence the SOP Class Common Extended Negotiation Sub-Items shall be omitted in the A-ASSOCIATE response.</para>
  <section label="D.3.3.6.1" status="5" xml:id="sect_D.3.3.6.1">
    <title>SOP Class Common Extended Negotiation Sub-Item Structure (A-ASSOCIATE-RQ)</title>
  
  <para xml:id="para_613eb9e5-f931-4741-aa6e-25ff06f43252">The SOP Class Common Extended Negotiation Sub-Item shall be made of a sequence of mandatory fields, the last two of which may be zero-length. Multiple SOP Class Common Extended Negotiation Sub-Items may be present in the User Data Item of the A-ASSOCIATE-RQ, however, only one Sub-Item per SOP Class UID shall be present. <xref linkend="table_D.3-12" xrefstyle="select: label"/> shows the sequence of mandatory fields.</para>
    <table frame="box" label="D.3-12" rules="all" xml:id="table_D.3-12">
    <caption>SOP Class Common Extended Negotiation Sub-Item Fields (A-ASSOCIATE-RQ)</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_5c2c7f30-2c29-4bb0-a5e8-d36aceee8d28">
          <emphasis role="bold">Item Bytes</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_2f24ad0e-180a-4cb0-a313-0835fea1901b">
          <emphasis role="bold">Field Name</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_b0bd2f97-488d-45e0-8be7-000de9e8274e">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6be4075b-f59a-489e-866d-5fc7058c8bc8">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f2e37a98-13e7-45e0-be5a-07f30f4af5d1">Item-type</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0c9f61a5-9bad-4363-9194-a5b5e543c1af">57H</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7a724c10-51da-4340-a298-8dde894b9ec2">2</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c2fa92a0-8d0e-4a0d-af39-17918524d660">Sub-Item-version</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_7001f685-5e49-490d-9964-2beca1b28ed5">This field indicates the version of the Sub-Item. Fields added to the Sub-Item definition in succeeding editions of the Standard will not affect the semantics of previously defined fields. The version of the Sub-Item defined in this edition of the Standard is 0.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d3c6d8d6-a1af-406f-a9e0-6a19a683efee">3-4</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6b23d28c-bd68-4aef-bdb0-c1ed5ed704dc">Item-Length</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_ebbbee73-e4e4-4c67-89a9-b10679fe3373">This Item-length shall be the number of bytes from the first byte of the following field to the last byte of the Reserved field. It shall be encoded as an unsigned binary number.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_dee7a604-f0a1-4f59-9743-7d4d47bc7e30">5-6</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d55badad-324e-4fa0-97f2-ce33c46a5cb4">SOP-class-uid-length</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_28d01bc4-fe83-42b0-af9a-b4c1957cb909">The SOP-class-uid-length shall be the number of bytes in the SOP-class-uid field. It shall be encoded as an unsigned binary number.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_07a9340e-f6e5-4eff-a290-492f7cee3403">7-x</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_17ee4fde-a1ed-4134-a52e-244ec9821eb6">SOP-class-uid</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_074f4df0-0251-4831-bf56-59973a5fcfcf">The SOP Class identifier encoded as a UID as defined in <olink targetdoc="PS3.5" targetptr="chapter_9" xrefstyle="template:Section %n “%t” in PS3.5"/>.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_7e382799-6d07-4556-80c2-499bf6f7d74f">(x+1) - (x+2)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e5acd048-cf0c-4613-be46-db3ff82659b6">Service-class-uid-length</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0485f7e2-2dff-457b-b1c0-9dd3afba5f4a">The Service-class-uid-length shall be the number of bytes in the Service-class-uid field. It shall be encoded as an unsigned binary number.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_69469153-8b63-49ac-90cf-2e8e983cf9ef">(x+3) - y</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_dc308de3-1a1e-4a88-a760-4677759a081c">Service-class-uid</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_397240b0-9b52-4948-9b97-438100981009">The Service Class identifier encoded as a UID as defined in <olink targetdoc="PS3.5" targetptr="chapter_9" xrefstyle="template:Section %n “%t” in PS3.5"/>.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_aa220aab-9bc0-4abf-a5aa-4193705f0c0f">(y+1) - (y+2)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_8eb9d61e-12a7-4316-8998-6fa62be5d3b9">Related-general-sop-class-identification-length</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_22fd0195-d8cd-45f7-882a-8cd74275e100">The Related-general-sop-class-identification-length shall be the number of bytes in the Related-general-sop-class-identification field. Shall be zero if no Related General SOP Classes are identified.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8cd5d52f-fee5-4dd8-acc8-c89f1d832a25">(y+3) - z</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_141bea82-729e-4702-aa74-8bb61d295f9b">Related-general-sop-class-identification</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1062e2e2-2fce-4631-a804-65025851abec">The Related-general-sop-class-identification is a sequence of pairs of length and UID sub-fields. Each pair of sub-fields shall be formatted in accordance with <xref linkend="table_D.3-13" xrefstyle="select: label"/>
</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_04a206a5-ce99-44d8-9eac-fb865d027d83">(z+1) - k</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6f17e2d3-a39e-432f-ba08-f1fce2a1e874">Reserved</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a6ab5804-3c99-40f4-b546-1025d1bf669b">Reserved for additional fields of the sub-item. Shall be zero-length for Version 0 of Sub-Item definition.</para>
      </td>
    </tr>
   </tbody>
  </table>
    <table frame="box" label="D.3-13" rules="all" xml:id="table_D.3-13">
    <caption>Related-General-SOP-Class-Identification Sub-Fields</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_47ba6277-ad11-4021-a9f2-57016f762606">
          <emphasis role="bold">Bytes</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_ada6aaea-fb3e-4512-b7e0-78689e75ac9f">
          <emphasis role="bold">Sub-Field Name</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_a71aa9cb-7d5f-4d7e-aa20-272d7e934512">
          <emphasis role="bold">Description of Sub-Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f49d8354-21f6-4b80-ab80-b5a4cd5c7102">1-2</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a10a8e54-5309-49cd-8d5e-e24d7d35bbe9">Related-general-sop-class-uid-length</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_596635e3-6ff7-4fb8-87d9-ecb7b47cf07c">The Related-general-sop-class-uid-length shall be the number of bytes in the Related-general-sop-class-uid sub-field. It shall be encoded as an unsigned binary number.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8dd568f3-8496-46fe-a7f7-f658cbb371d6">3-n</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_33356b54-196e-4214-8c19-3d249e1ce097">Related-general-sop-class-uid</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
          <para xml:id="para_2e95f653-0c7a-4048-bc93-c23c86d179c2">The Related General SOP Class identifier encoded as a UID as defined in <olink targetdoc="PS3.5" targetptr="chapter_9" xrefstyle="template:Section %n “%t” in PS3.5"/>.</para>
      </td>
    </tr>
   </tbody>
  </table>
  </section>
</section>
<section label="D.3.3.7" status="4" xml:id="sect_D.3.3.7">
    <title>User Identity Negotiation</title>
  
  <para xml:id="para_c76d31f1-77e6-442b-a30d-5d1dab8537a8">The User Identity Negotiation is used to notify the association acceptor of the user identity of the association requestor. It may also request that the association acceptor respond with the server identity. This negotiation is optional. If this sub-item is not present in the A-ASSOCIATE request the A-ASSOCIATE response shall not contain a user identity response sub-item.</para>
  <para xml:id="para_f091ab35-d0f1-4f10-8a5b-c4c1338240d7">The Association-requestor conveys in the A-ASSOCIATE request:</para>
<itemizedlist>
  <listitem>
    <para xml:id="para_df2b7b69-7b34-4e4a-a627-a88c6cd6f2dd">the form of user identity being provided, either a username, username and passcode, a Kerberos service ticket, a SAML assertion, or a JSON Web Token (JWT).</para>
</listitem>
  <listitem>
<para xml:id="para_b779f9d1-556e-4ba4-9978-e82730302c0b">an indication whether a positive server response is requested.</para>
</listitem>
</itemizedlist>
  <para xml:id="para_16475d05-c582-4e73-8195-556032c4b470">The Association-acceptor does not provide an A-ASSOCIATE response unless a positive response is requested and user authentication succeeded. If a positive response was requested, the A-ASSOCIATE response shall contain a User Identity sub-item. If a Kerberos ticket is used the response shall include a Kerberos server ticket.</para>
  <para xml:id="para_08c20b0b-cbba-475d-ba82-63ff1ca56e88">Since a system may ignore request sub-items, the positive response must be requested if the association requestor requires confirmation. If the association acceptor does not support user identification it will accept the association without making a positive response. The association requestor can then decide whether to proceed.</para>
  <para xml:id="para_f7d8429f-722e-4793-ac68-7d975c56b89a">The association acceptor may utilize the User Identity information provided during the association negotiation to populate the user information fields in DICOM audit trail messages. The association acceptor may utilize the User Identity information provided during the association negotiation to perform authorization controls during the performance of other DIMSE transactions on the same association. The user identity information may also be used to modify the performance of DIMSE transactions for other purposes, such as workflow optimizations.</para>
  <note>
    <orderedlist>
      <listitem>
        <para xml:id="para_3d58d59a-44a3-4507-a671-ca2ede3f6f84">User identity authorization controls may be simple "allow/disallow" rules, or they can be more complex scoping rules.
            For example, a query could be constrained to apply only to return information about patients that are associated with the identified user.
            The issues surrounding authorization controls can become very complex.
            The User Identity Negotiation conveys user identity to support uses such as authorization controls and audit controls.
            It does not specify their behavior.</para>
      </listitem>
      <listitem>
          <para xml:id="para_25be324b-a5b9-4a62-8a61-9cfa8186b8e2">The option to include a passcode along with the user identity enables a variety of non-Kerberos secure interfaces. Sending passwords in the clear is insecure, but there are single use password systems such as <xref linkend="biblio_RFC_2289"/> and the various smart tokens that do not require protection. The password might also be protected by TLS or other mechanisms.</para>
      </listitem>
      <listitem>
          <para xml:id="para_e0a4881e-8cfa-43cb-81d8-c7ae30de7853">For JSON Web Tokens (JWTs), <xref linkend="biblio_RFC_7519"/> specifies minimal requirements for encryption, MAC and signature algorithms;
          others may be supported as described in the DICOM Conformance Statement.
          The encoded format in the Primary-field of the A-ASSOCIATE-RQ is the same as what might be included in an HTTP Authorization: Bearer header field
          per <xref linkend="biblio_RFC_6750"/> when accessing a Protected Resource on a Resource Server.
          If the same trust mechanisms are used by both the DIMSE SCP and the Resource Server, the contents of the Primary-field can be the same as the value of the HTTP Authorization: Bearer field, avoiding the need to perform a conversion of the contents.</para>
      </listitem>
        <listitem>
            <para xml:id="para_aff0690e-b8f5-4752-8e3b-fc4f1be50bbd">Care should be taken to not include unnecessary protected content from the User Identity Negotiation into audit log messages.
                For example, the password, SAML Assertion, and JSON Web Token (JWT) could be disclosed if included in a log message.
                A service such as the OAuth Introspection Service (<xref linkend="biblio_RFC_7662"/>) might be needed to obtain unprotected user identity information from a SAML Assertion or JWT.</para>
        </listitem>
    </orderedlist>
  </note>
      <para xml:id="para_a34023c6-fe58-40d1-841e-6aabb30b3c74">
<figure label="D.3-8" pgwide="1" xml:id="figure_D.3-8">
<title>User Identity Negotiation (With Server Positive Response Requested)</title>
<mediaobject>
<imageobject>
<imagedata fileref="figures/PS3.7_D.3-8.svg"/>
<!--<imagedata fileref="part07_fromword_files/image032.png"/>-->
</imageobject>
</mediaobject>
</figure>
</para>
  <para xml:id="para_1a53230a-b3ff-45ac-90d3-522c056b4870">
<figure label="D.3-9" pgwide="1" xml:id="figure_D.3-9">
<title>User Identity Negotiation (Application Entity "A" Provides Username Identity)</title>
<mediaobject>
<imageobject>
<imagedata fileref="figures/PS3.7_D.3-9.svg"/>
<!--<imagedata fileref="part07_fromword_files/image034.png"/>-->
</imageobject>
</mediaobject>
</figure>
</para>
  <section label="D.3.3.7.1" status="5" xml:id="sect_D.3.3.7.1">
    <title>User Identity Sub-Item Structure (A-ASSOCIATE-RQ)</title>
  
  <para xml:id="para_66fe0dcb-c842-46fe-8fe3-1a7920b6548e">The User Identity Negotiation Sub-Item shall be made of a sequence of mandatory fixed and variable length fields. This Sub-Item is optional and if supported, only one User Identity Negotiation Sub-Item shall be present in the User Data Item of the A-ASSOCIATE-RQ. <xref linkend="table_D.3-14" xrefstyle="select: label"/> shows the sequence of the mandatory fields.</para>
    <table frame="box" label="D.3-14" rules="all" xml:id="table_D.3-14">
    <caption>User Identity Negotiation Sub-Item Fields (A-ASSOCIATE-RQ)</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_cd79f7fd-4284-4048-926d-c8876620d437">
          <emphasis role="bold">Item Bytes</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_dde78d9e-b050-48c9-9d99-0668334be29b">
          <emphasis role="bold">Field Name</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_1b9b9811-e0d5-465f-9558-4e087b56f7fd">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c34b5580-f1d1-4ce5-908f-5da2ce06b197">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_4ce3acd5-0852-49cd-86fc-8e22972ad86f">Item-type</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a847689b-6e45-4474-b302-b3de9826aeac">58H</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_86b6e57a-e23a-47f1-88fe-ad6f90d7acc2">2</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_134f44ba-23f1-435a-8050-27bc96df3787">Reserved</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_07ab309a-475d-42b7-99be-7204d7933438">This reserved field shall be sent with a value 00H but not tested to this value when received.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d61fe0fa-bfa7-4d45-8fd0-257ce1c5c649">3-4</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f6e65b9d-9e24-4f20-b01d-f4f0038cc7b4">Item-length</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_191afbc3-3722-4792-8075-146f2fe6dd0b">This Item-length shall be the number of bytes from the first byte of the following field to the last byte of the last field sent. It shall be encoded as an unsigned binary number.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e38a92f3-ad2d-4bde-ae28-d65ec405ceb2">5</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_7046e441-c86c-4e31-917d-aa42236003ba">User-Identity-Type</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_276328ba-b1b2-4841-b8d1-612735e34600">Field value shall be in the range 1 to 5 with the following meanings:</para>
        <para xml:id="para_4e42d526-3c88-415e-ab36-ace6943a17ee">1 - Username as a string in UTF-8</para>
        <para xml:id="para_3f5dda40-8c82-4a32-8b37-43ecd740a261">2 - Username as a string in UTF-8 and passcode</para>
        <para xml:id="para_7279eb99-7d15-4c8c-9493-9d33ce1e16f7">3 - Kerberos Service ticket</para>
        <para xml:id="para_28d78e48-430a-434e-bad4-0bc80493c981">4 - SAML Assertion</para>
        <para xml:id="para_c43bc73a-22b9-4a4f-848b-55ba68f10b10">5 - JSON Web Token (JWT)</para>
        <para xml:id="para_00a0a098-3fe2-457d-983a-86d07afa0b3e">Other values are reserved for future standardization.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d6c2d595-167f-48c2-b53d-41b34d39b3f7">6</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3ccb512b-cbe7-4ea0-8dc2-b576e82ad31a">Positive-response-requested</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_284c25b8-3ac0-48f8-bfcf-3d52030e362c">Field value:</para>
        <para xml:id="para_1c377ddd-da50-4c39-8f9a-969c236a163c">0 - no response requested</para>
        <para xml:id="para_b355d9d8-0d0f-43f0-a3b7-63cfa0546593">1 - positive response requested</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_fa96cc4d-26f8-4b8d-bfa3-4b9759a7c2fb">7-8</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_ce309a27-26ee-4ad8-ab77-3b9e243ce887">Primary-field-length</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_eecfa7a3-81a1-4a24-8a40-6af305d32691">The User-Identity-Length shall contain the length of the User-Identity value.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_493e2b34-3a25-4c05-8a76-596cd1c61a6a">9-n</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_357a710b-ee5f-444d-90dd-c228ec8fb24b">Primary-field</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
          <para xml:id="para_c9e1766b-5a4c-4c9c-aa6a-da3d65f7a7c9">This field shall convey the user identity, either the username as a series of characters, or the Kerberos Service ticket encoded in accordance with <xref linkend="biblio_RFC_1510"/>,
              or the JWT encoded in accordance with <xref linkend="biblio_RFC_7519"/> using base64url encoded parts.</para>
      </td>
    </tr>
    <tr valign="top">
        <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c10f8178-8054-4be8-9409-ab736c53f734">n+1-n+2</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b2935ebc-e298-48f2-ad41-3fee750a8f2d">Secondary-field-length</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_4a564ccc-99e9-45f7-bf48-c4ff9852112d">This field shall be non-zero only if User-Identity-Type has the value 2. It shall contain the length of the secondary-field.</para>
      </td>
    </tr>
    <tr valign="top">
        <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_97dec233-6693-4624-83f2-c7f727786604">n+3-m</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a8f9d8b8-90f0-4082-9714-49b60458acfa">Secondary-field</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_50df7480-a400-4fde-8e47-3a4a73366b26">This field shall be present only if User-Identity-Type has the value 2. It shall contain the Passcode value.</para>
      </td>
    </tr>
   </tbody>
  </table>


  </section>
<section label="D.3.3.7.2" status="5" xml:id="sect_D.3.3.7.2">
    <title>User Identity Sub-Item Structure (A-ASSOCIATE-AC)</title>
  
  <para xml:id="para_80c88f20-7f55-424a-9bc4-161717932a9c">The User Identity Sub-Item shall be made of a sequence of mandatory fixed and variable length fields. This Sub-Item is optional and if supported, only one User Identity Sub-Item shall be present in the User Data Item of the A-ASSOCIATE-AC. <xref linkend="table_D.3-15" xrefstyle="select: label"/> shows the sequence of the mandatory fields.</para>
    <table frame="box" label="D.3-15" rules="all" xml:id="table_D.3-15">
    <caption>User Identity Negotiation Sub-Item Fields (A-ASSOCIATE-AC)</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_92afa1d4-14be-4c99-91df-db8e9ab7e62c">
          <emphasis role="bold">Item Bytes</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_d906d76d-66c6-458f-b15e-2de61ac1d30b">
          <emphasis role="bold">Field Name</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_e53563a6-2ab8-4969-a1ea-0c9d7ca7fc7b">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d7cc2bc4-3eea-4860-be6e-d93b4cecae4e">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_7cf17edf-e40c-4a59-ad15-22dfac19a153">Item-type</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_30952e18-52b0-4d90-bdb6-30ab99514b44">59H</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9c52505f-1c05-4ee4-8b25-c0b30186ae73">2</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_97a4f1a0-bbd9-4a6c-a0e8-447f1515bd1f">Reserved</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_955d17ee-68f6-4d35-8cda-f9849522653d">This reserved field shall be sent with a value 00H but not tested to this value when received.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c845ab52-4ad9-4523-ba75-47c01be2fa56">3-4</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_21081b99-c89e-4a56-a9e4-79a39e3d231f">Item-length</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_60b16db0-959d-4e02-b124-79e59e9182dc">This Item-length shall be the number of bytes from the first byte of the following field to the last byte of the final field. It shall be encoded as an unsigned binary number.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_09e278c6-937a-4289-a226-34d9fe20500b">5-6</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_952dab6e-36b8-43fd-9538-8604bfa6901a">Server-response-length</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a257685c-12fe-4161-af1e-82c71fe38bc0">This field shall contain the number of bytes in the Server-response. May be zero.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_43e2ce62-a3ac-4cdd-bcfa-3a993de823b3">7-n</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_612107a4-e4b1-4054-b7f8-d364252c4021">Server-response</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
          <para xml:id="para_85393e83-e311-47f8-94f2-a0971f58a549">This field shall contain the Kerberos Server ticket, encoded in accordance with <xref linkend="biblio_RFC_1510"/>, if the User-Identity-Type value in the A-ASSOCIATE-RQ was 3. This field shall contain the SAML response if the User-Identity-Type value in the A-ASSOCIATE-RQ was 4. This field shall be zero length if the value of the User-Identity-Type in the A-ASSOCIATE-RQ was 1 or 2.</para>
      </td>
    </tr>
   </tbody>
  </table>


  <para xml:id="para_498461f3-a2e1-4c1c-be00-c167976c315f">If the Association-Requestor has requested a positive acknowledgment, the Server-response shall be returned with the Kerberos Server ticket when User-Identity-Type is Kerberos Service ticket (3).</para>
  </section>
<section label="D.3.3.7.3" status="5" xml:id="sect_D.3.3.7.3">
    <title>User Identity Rejection</title>
  
  <para xml:id="para_a1290099-b8d1-41f9-8d4a-1beacd968dd8">The association acceptor may utilize the username or username and passcode information to determine whether the user is permitted to establish an association. If the Kerberos mechanism is chosen, the association acceptor shall utilize the Kerberos service ticket to determine whether the user is permitted to establish an association.</para>
  <para xml:id="para_075a639b-1222-41fb-9b42-4e0d0c47bc2c">If the association acceptor rejects the association because of an authorization failure, the rejection shall be indicated to be rejected-permanent (see <olink targetdoc="PS3.8" targetptr="PS3.8" xrefstyle="select: labelnumber"/>). The source shall be value (2) "DICOM UL service provided (ACSE related function) ". The rejection is indicated to be rejected-permanent because retries with the same user identity fields will continue to be rejected. A different and valid username, username and passcode, or Kerberos ticket must be provided.</para>
  <para xml:id="para_b4ca9ef8-691e-4df0-9688-44c33da0be03">This Standard does not define how the association acceptor performs authentication or what rules apply to this authentication.</para>
  
  </section>
</section>
</section>
</section>
</chapter>
<chapter label="E" status="1" xml:id="chapter_E">
    <title>Command Dictionary (Normative)</title>
  
  <section label="E.1" status="2" xml:id="sect_E.1">
    <title>Registry of DICOM Command Elements</title>
  
    <table frame="box" label="E.1-1" rules="all" xml:id="table_E.1-1">
    <caption>Command Fields</caption>
    <thead>
   <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_dc41cdd3-1cf8-4093-a749-3efb1a95bcf2">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_1c62e73c-ed73-4e13-953d-3985745fd5df">
          <emphasis role="bold">Message Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_098214f2-d180-4bcc-be16-994fa0d28765">
          <emphasis role="bold">Keyword</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_4f262ed6-6784-48a1-903f-39e318f2622f">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_ca27c3bb-b6fa-42c9-adbd-1734d3588913">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_58221eb2-0e57-445c-90fd-6688b0632fec">
          <emphasis role="bold">Description of Field</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

     <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_32d86c00-f704-4787-bac6-df4f967a974a">(0000,0000)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_8cda3b1e-ef71-4c3b-bd46-7ef58695edf2">Command Group Length</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_773d4b16-a32b-4105-b552-e23c57c2c558">CommandGroupLength</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6d75a9e5-2efd-44fc-abf1-99962a415258">UL</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f64bd98c-a369-471a-a0e9-218092c12453">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3ccfa4fc-0261-4383-a8f2-18098a986eef">The even number of bytes from the end of the value field to the beginning of the next group.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a3bbe4ca-1beb-45c2-baed-5a52b002cfe5">(0000,0002)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5381f34d-82ac-47b0-b373-fc9935e034d3">Affected SOP Class UID</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_329e1ce6-0b4b-422f-9336-f430afae38ad">AffectedSOPClassUID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1faf918a-87c9-4d1f-827b-66188e9ee968">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_37aec0f4-5ce5-42cf-b784-d9906b0c3444">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_dae1a52c-f122-4e47-b305-383a58aa8d91">The affected SOP Class UID associated with the operation.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_88c0d9c4-eefa-413d-9735-dc5ac502a305">(0000,0003)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0ffce336-2a1b-474f-9029-0a7839ac0625">Requested SOP Class UID</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c7a66a01-ad53-4466-92e1-55d973c71089">RequestedSOPClassUID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ffebd717-0546-4d67-a985-ca09c403e673">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a3c81162-2e7b-4a64-ae9d-91da52c4d513">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1f628968-9bbb-429e-8dde-e22c0567db19">The requested SOP Class UID associated with the operation.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c2f1b58d-3b30-4dd1-bb69-32d7672116e9">(0000,0100)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_11b7ca51-898e-4806-a969-45b0ec78944e">Command Field</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_49954f6c-075f-45d7-87fc-00147bc52b04">CommandField</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4201812b-4a7f-42d9-aabe-d655ce90feed">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f1b61919-254d-415e-ac40-04caedf8c8ec">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0f783436-6289-4d20-a19b-3c3a806c53e7">This field distinguishes the DIMSE operation conveyed by this Message. This field shall be set to one of the following values:</para>
        <para xml:id="para_173495ad-5024-412d-9ad4-5ccc4d527b30">0001H C-STORE-RQ</para>
        <para xml:id="para_ff9d05c1-e853-4815-a37b-04dbec212732">8001H C-STORE-RSP</para>
        <para xml:id="para_73d79fae-95a3-487e-8487-5212590e9f67">0010H C-GET-RQ</para>
        <para xml:id="para_44eca31a-b206-4f3d-87a4-7d7683a2205f">8010H C-GET-RSP</para>
        <para xml:id="para_42938c88-86dd-445f-ae54-0d1f1d81bc23">0020H C-FIND-RQ</para>
        <para xml:id="para_a3053ce3-51cf-40ed-bb53-8ea272f6c893">8020H C-FIND-RSP</para>
        <para xml:id="para_af78a437-ef60-40cb-a1b2-2a859d8a03d6">0021H C-MOVE-RQ</para>
        <para xml:id="para_add6bdd9-8366-40be-b532-f282aa28600c">8021H C-MOVE-RSP</para>
        <para xml:id="para_e64d57df-2e03-437a-b831-3a79b027cdb1">0030H C-ECHO-RQ</para>
        <para xml:id="para_7e31dd3d-b98f-45b3-b4f1-10278760dafe">8030H C-ECHO-RSP</para>
        <para xml:id="para_07ea6c20-ea0f-47b6-af2f-f7a3787e0d3e">0100H N-EVENT-REPORT-RQ</para>
        <para xml:id="para_99506906-7cbc-4a5c-b916-12abe99dfb06">8100H N-EVENT-REPORT-RSP</para>
        <para xml:id="para_4250a288-c4f7-484f-9597-658dc3ecbb1b">0110H N-GET-RQ</para>
        <para xml:id="para_54af94b2-5fdd-48fa-9197-0f314e251ff3">8110H N-GET-RSP</para>
        <para xml:id="para_47f3f781-3aa1-496d-ae15-3bd29cc79ee0">0120H N-SET-RQ</para>
        <para xml:id="para_2aac26d6-2999-4153-bc01-daa8166354b5">8120H N-SET-RSP</para>
        <para xml:id="para_c4a9e35f-040a-4c31-bba7-3e54b2ab5ce7">0130H N-ACTION-RQ</para>
        <para xml:id="para_e29a9334-4849-4648-bb6b-7c9d9df69955">8130H N-ACTION-RSP</para>
        <para xml:id="para_ea288910-c966-4369-8f70-3c2bc895b843">0140H N-CREATE-RQ</para>
        <para xml:id="para_988f400b-4459-4d33-a5a1-bf37ebd9c474">8140H N-CREATE-RSP</para>
        <para xml:id="para_6e65ff6b-1e54-4ed0-b780-d5af4cd47c0d">0150H N-DELETE-RQ</para>
        <para xml:id="para_1bc83add-e044-4243-8eb4-0812cabc03f1">8150H N-DELETE-RSP</para>
        <para xml:id="para_bb450519-568b-46b5-9605-e34e76af564b">0FFFH C-CANCEL-RQ</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e580202e-8922-4972-b1b7-e38f6d4b8fd6">(0000,0110)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_4e237ae8-aaca-429c-b32e-b33e5696386e">Message ID</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_474b4448-b3f4-4f01-b146-0891348fa779">MessageID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ef1845e4-6502-4290-8c6e-358fae049a01">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0e3550b6-9490-40de-a557-f2990bb739bd">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b03e16a8-2265-408e-8d1b-5cdf068e7650">Implementation-specific value that distinguishes this Message from other Messages.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_db92661c-c83e-437b-944b-1b44799e04b4">(0000,0120)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_543f1830-88bd-4690-aca5-1ecb57cf1417">Message ID Being Responded To</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_39636775-93ce-428d-902b-2bd40296023a">MessageIDBeingRespondedTo</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_eb439084-5c66-4632-a43e-2f24b78257a4">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0d53e37b-c372-4685-a1af-7e233dce529d">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0bf69a17-aada-4dc0-827e-62e3b3ac5d5e">Shall be set to the value of the Message ID (0000,0110) field used in associated request Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a57a4167-eff1-4cbf-8581-55b80d704a4b">(0000,0600)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_da4fb8e2-a2b8-4d55-8e5e-815095b1b7cd">Move Destination</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_62271c74-7e1f-4e29-b79a-bb9601d162e9">MoveDestination</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_9448cd65-d01b-4051-87a7-f2a37dcbc1b9">AE</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b670f71b-0e15-4db5-b281-e7910ae63194">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c45299c9-8cdf-44b6-bf02-7af34506a095">Shall be set to the DICOM AE Title of the destination DICOM AE to which the C-STORE sub-operations are being performed.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e02aea61-b8e3-4f30-8927-d5a54dd77b78">(0000,0700)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_903676df-e0fb-44a1-9bf5-4587d8b782aa">Priority</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_41725d49-379b-4c97-824f-cdefab2817eb">Priority</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6b2cc5e9-0070-449e-ab02-cbfe8278577e">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_163ff1da-7e95-4854-87fa-fc103465c051">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_96a1d5fe-3617-4478-84ca-541b6f79309d">The priority shall be set to one of the following values:</para>
        <para xml:id="para_6ef56b87-2d03-4b71-8a23-5be606a7545f">LOW = 0002H</para>
        <para xml:id="para_069c3de5-f75a-4b0b-bba1-223a3ca35ad1">MEDIUM = 0000H</para>
        <para xml:id="para_066374cb-35fc-4053-8fb7-e84119734d9f">HIGH = 0001H</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ea7fe44f-fec8-427e-a4a0-3094fcfd2485">(0000,0800)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e7651a93-9e4f-4951-b5ff-d6b28fe498a5">Command Data Set Type</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_280ce12c-b4c6-407d-acdc-de85b4e17b92">CommandDataSetType</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_25f969a6-9481-48c8-8bb3-dd95334b877e">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a2aee880-f00d-4538-a3a0-0c9007b6b69f">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_2f8bf0d3-2058-4b45-aa2b-8e9985751a1c">This field indicates if a Data Set is present in the Message. This field shall be set to the value of 0101H if no Data Set is present; any other value indicates a Data Set is included in the Message.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ccd1bc9b-246c-46cf-8b9c-7c606bf7e70c">(0000,0900)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_802f5064-5138-4919-a9fb-dc296afa81c8">Status</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_2b36a6d1-7f9f-41b4-b381-dc86d93809d0">Status</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_811086fe-925c-4013-8681-674655ca1486">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0fd14a2e-8449-428f-a742-bfc55763b3d4">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f86b8ed6-2872-4130-b39a-c6ccdb35ea5c">Confirmation status of the operation. See <xref linkend="chapter_C" xrefstyle="template:Annex %n"/>.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_81ec99a4-cb73-466c-8ffb-9f835a699635">(0000,0901)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_768acad2-8661-4165-852b-5749e29dfda6">Offending Element</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_58d21a0f-6355-4073-aee2-e2bcf77a3926">OffendingElement</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_124c0703-8e70-4bdf-b0f0-2d6075319514">AT</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_179d8de6-c358-4dfe-a422-46db6d7e973d">1-n</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d8fad49c-d710-4622-a8a9-41f2d93ea8f8">If status is Cxxx, then this field contains a list of the elements in which the error was detected.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e34a29b0-eed2-4dbc-8a97-832ccf95fd15">(0000,0902)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_5eab9f12-3932-434b-b057-df0f12e4d483">Error Comment</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_31b9ebc3-c5d0-4e18-b674-f837fa46c06c">ErrorComment</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_28e76e30-93db-4f7f-bcc3-8d244c227e24">LO</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_dabb8e56-f107-428f-b90a-6ae2d89bf4ef">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9162584b-219c-44f7-946e-237f41ca2624">This field contains an application-specific text description of the error detected.</para>
          <note>
              <para xml:id="para_ede63766-e4b5-4ab3-acbd-e47e388a2325">Only characters from the Default Character Repertoire may be used.</para>
          </note>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_76429fa4-1d5c-4114-b1c6-7850cbac2e9a">(0000,0903)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_4dc406e7-4644-47c4-848d-545470a24bf4">Error ID</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d5978c46-1bcb-42f3-9428-2254ca363e1b">ErrorID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5f39deac-60fe-4902-8765-56e085f1d630">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c18f37b4-aa60-4374-831f-6c8b418f37e9">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_863b273c-f9f4-4602-9e89-db9891ab9c87">This field shall optionally contain an application-specific error code.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_323a449f-6450-4c59-894c-db44db613ddd">(0000,1000)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_85514886-88ea-4bef-9301-16caad12c0d4">Affected SOP Instance UID</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_142cee3c-d5ff-48f7-aa17-c1f31ed12df7">AffectedSOPInstanceUID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b2b1f635-2ffa-44cc-b86f-ae7d56923866">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_95a9be57-9b96-481d-9e81-7c735be1abad">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_db6bac27-e061-4d6f-bf49-d941cc140313">Contains the UID of the SOP Instance for which this operation occurred.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b9c62755-c904-4eb1-b038-76054f6550d5">(0000,1001)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6483285b-ecbd-436b-990f-6718b939899a">Requested SOP Instance UID</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9d7a0c11-f112-4a9f-a52e-73a0076e7cae">RequestedSOPInstanceUID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1c626c15-f9a2-44a5-a5e7-ba3157b33c4d">UI</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d8364fbd-6543-4516-bea1-e1581b22329d">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c50450f8-346c-4e07-963d-cccdfcc7cf63">Contains the UID of the SOP Instance for which this operation occurred.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_17521a81-49b7-4604-b5bc-bd07ee15b1fc">(0000,1002)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0dc03ec6-3b6b-4b9b-b981-77a9ae32ea78">Event Type ID</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_2ae26a8e-8d59-4d11-9a57-7ae7691d5406">EventTypeID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d45b6115-3b37-4c0f-97da-60acfb15d231">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c3b693d9-e9af-4075-a394-49f9a1ad1523">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_78ef024d-cd7e-442e-bb28-4ccf7bd8646a">Values for this field are application-specific.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8de45b5b-7d92-4e29-b068-654a3933da74">(0000,1005)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_841fdda8-3385-48e7-9c73-6d05c561ca1d">Attribute Identifier List</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_13e6f54e-4bf1-4225-b73d-495d0b777e46">AttributeIdentifierList</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_15fb9274-ef04-496d-929e-3fe1aba50003">AT</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e9a019f6-9382-4a58-a0ac-ac0a375019bf">1-n</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_bea52dc8-4f02-4b58-b665-0784fd57c425">This field contains an Attribute Tag for each of the n Attributes applicable.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_781fb240-691e-42fb-9759-78e476eac5ff">(0000,1008)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_54f7d6e0-6b56-4416-a1bc-ccbe288d7c5a">Action Type ID</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_4eb3a75a-2d25-47d5-bdf3-ca6a85f14348">ActionTypeID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0b454b15-70cf-4064-ad20-bf146434bb96">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c8b64663-6d55-47df-af77-7d8fa377888d">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1f6fd621-6d1f-422d-a793-84264e80fe3d">Values for this field are application-specific.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_13472cde-e4ef-40f2-9079-57b77f9c949f">(0000,1020)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1a1608f3-d8cf-44b4-a4d9-448bb302d278">Number of Remaining Sub-operations</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9cfe593e-c2dd-4272-8a54-74ccdd51386f">NumberOfRemainingSuboperations</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b3f80dd2-e207-4bd3-90f3-8516a96b15f9">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ff6e91fd-24ea-4856-90f2-596b14277537">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_dba55a4a-45b1-49d9-b842-9a4e7f82ee9d">The number of remaining C-STORE sub-operations to be invoked for the operation.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a241183b-7e38-4973-b396-2a3dc3c99fea">(0000,1021)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b184e65f-609c-4350-8c5c-b77a6d873285">Number of Completed Sub-operations</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_82652e3d-e24d-471b-998b-671a2c7a1001">NumberOfCompletedSuboperations</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_64cb3980-c948-458f-ab53-a33a90a8a577">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_74974b4d-be11-46b9-bbe1-ab74e1f6bf8f">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9e476730-d983-41f4-aa7e-6379171b4985">The number of C-STORE sub-operations associated with this operation that have completed successfully.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_003ecf48-180f-46d4-b5d3-f5d9bd490587">(0000,1022)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_aa682b4b-a0dc-47fd-8ad8-5631d0ae23ee">Number of Failed Sub-operations</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_fed72179-335d-4118-aeb5-9ef4212429c5">NumberOfFailedSuboperations</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_74205870-d649-44bc-b9c8-c2ad4c26ffba">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d4885a31-f759-492b-ab5c-4e297de966f8">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_3dda6818-2101-4fde-8c29-6c2c4c265faa">The number of C-STORE sub-operations associated with this operation that have failed.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5d48acdb-781f-48d3-b893-de64305e39fc">(0000,1023)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_188772d7-9b4a-47ea-99c2-59b7afa791a9">Number of Warning Sub-operations</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_0808d305-f9df-4ea9-9b03-16b4ecaaeb30">NumberOfWarningSuboperations</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_152f61e0-aaea-49db-be5d-b750e86802b2">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_bb6ed7fa-4dd3-4acc-aa54-86e745da5bba">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_cf2e641c-4dfd-4f27-9f71-ccd1eac5310e">The number of C-STORE sub-operations associated with this operation that generated warning responses.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_38d1fb92-ad7e-4a51-8d49-dc43ff89d0c2">(0000,1030)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f410beb5-dddf-42ea-b0cc-c3181e6ccac4">Move Originator Application Entity Title</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_785ce2d3-0f49-43e1-839e-79843e2f3fc3">MoveOriginatorApplicationEntityTitle</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ea15656a-084a-40eb-a923-8447b6d9ee78">AE</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ec88c0a0-0318-4a83-ad66-87a6288dfd74">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d285ecd7-3232-43c5-8e90-68ac79a9f8cf">Contains the DICOM AE Title of the DICOM AE that invoked the C-MOVE operation from which this C-STORE sub-operation is being performed.</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_fd9ab755-7e76-436b-ab41-1db63fb83442">(0000,1031)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f340ccee-4c58-466b-a5b3-9b1643387418">Move Originator Message ID</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_4ddd66f9-7b07-440d-b32f-3d8d9581c50e">MoveOriginatorMessageID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a0a68540-34d9-41ce-81e1-15625a045a60">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0837d2f7-b0d4-467a-9aaf-60ba4c75c33c">1</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e7cefe15-aa31-4353-a035-be54f457df9f">Contains the Message ID (0000,0110) of the C-MOVE-RQ Message from which this C-STORE sub-operation is being performed.</para>
      </td>
    </tr>
   </tbody>
  </table>


  </section>
<section label="E.2" status="2" xml:id="sect_E.2">
    <title>Retired Command Fields</title>
  
  <para xml:id="para_191ab995-631b-440c-af47-04080601b295">The following command fields have been retired but are listed here for compatibility with previous versions of this Standard. Reference <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/> for more information on retired Data Elements and Command Elements.</para>
    <table frame="box" label="E.2-1" rules="all" xml:id="table_E.2-1">
    <caption>Retired Command Fields</caption>
    <thead>
    <tr valign="top">
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_d62f2f11-09d3-4e23-a529-eb45dcfec2f4">
          <emphasis role="bold">Tag</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_56094014-9d25-44fa-8b4a-797bd9aa24ba">
          <emphasis role="bold">Message Field</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_7d8e9d06-73da-46a3-b583-0880d97482f9">
          <emphasis role="bold">Keyword</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_9b80c358-f4e3-42fa-a9a0-b4ff04853f35">
          <emphasis role="bold">VR</emphasis>
        </para>
      </th>
      <th align="center" colspan="1" rowspan="1">
        <para xml:id="para_76de7f2a-456b-4810-9f5f-d21a085d9116">
          <emphasis role="bold">VM</emphasis>
        </para>
      </th>
    </tr>
    </thead>
    <tbody>

    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_da6567cc-2477-4483-a5d9-03c669e57d53">(0000,0001)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_fbff5d25-a4ae-4339-afe3-f728e60b63a5">Command Length to End</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_af6f9684-fc12-470c-a164-c85791d153fb">CommandLengthToEnd</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_979ec487-397c-4829-bf4d-fc3e120a4416">UL</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e1276e64-287f-4f9e-8ba7-7de903bd8939">1</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_54c37c22-42c6-4d4f-9849-f582f68152f1">(0000,0010)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b1e2d8cc-4a08-4055-9065-fcde03e263fe">Command Recognition Code</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a811bc97-e22a-4586-9adf-6ceb31a9e4b5">CommandRecognitionCode</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_aee63473-c2f2-4dd6-aa22-9049a4aa7a54">SH</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_682c8a2f-5452-4f77-a3e8-173aed19f5c8">1</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c93a5bf4-710b-4c3b-827f-ed0de2c207c6">(0000,0200)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_2cc76553-c9a8-4e52-a739-3dee7c79006c">Initiator</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_36960641-5ada-4a76-a485-72b2dc3a1404">Initiator</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a527410c-b57c-4e99-9e6d-32a313f92b6f">AE</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_0b9cb1d3-79e8-4c05-99df-ca5821f57af4">1</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a6a6f94a-1a6b-4577-b0b1-d77faece0de8">(0000,0300)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_cc675d33-03f6-4b66-b318-db2c9f85a0b3">Receiver</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a0fb4872-4e38-41c4-867d-10c0e65ced39">Receiver</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c36a56d1-10dc-4066-bd5a-1762b057786e">AE</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_abe5cc26-01de-4e1f-85f0-5e766c476abe">1</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b9c3c032-685e-4a88-87b0-637d25c5157a">(0000,0400)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_8d08cf03-bdfe-446d-8619-14cb190d1cc9">Find Location</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c8f361b2-0412-4ae9-bf36-55923ec1cca7">FindLocation</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4e0ad9d1-ad52-470d-9811-45bae75a1c70">AE</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e0c34186-fa8d-4f54-9dcd-6b4d16771e54">1</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_62de4899-be86-4417-a906-2423935028ed">(0000,0850)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_42ae8f2f-bd99-4f8b-b4d2-687b5816b341">Number of Matches</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_140b978c-d789-47c2-a8c7-7c5ebe15b581">NumberOfMatches</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_2d8734ea-3dad-4523-930c-e6d607b9082c">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f103eedc-c28a-45a2-bc8f-24da6a064115">1</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_fb33b63e-102e-4866-b3dc-7e20e6c90877">(0000,0860)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_fb3b5250-fc91-4bd1-b7ec-1b519c3a0650">Response Sequence Number</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_cca31998-1248-4b90-841d-7dd0a351548d">ResponseSequenceNumber</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_19ba340d-e3de-4965-a861-8edb5edc42f3">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c4745076-bab1-4c16-b2b5-86888c2b8324">1</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e81ad275-68ed-45ef-9c7a-923aebcaadb7">(0000,4000)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6d52a48c-03c9-4a56-a546-f461805fc61d">Dialog Receiver</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_df2dba12-c2c1-41b8-8215-e2da05fb725f">DialogReceiver</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_24fc8e39-05a5-4d34-8280-8cca725657a8">LT</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_09e99551-1d81-4148-b22b-bbc30c60f276">1</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c90333c8-e58e-4f46-aca0-36ca0441f9f3">(0000,4010)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c431c88d-6e50-4574-9475-3efb6d9c7776">Terminal Type</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_1df9a142-53ee-475d-9c5b-806a30aac19e">TerminalType</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f36b9fe3-d321-4fc2-b771-fafd773206d6">LT</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_cda6aaa5-c298-4bfd-becd-5762f66f8973">1</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d8810bc5-729d-4deb-9143-169a257d8236">(0000,5010)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_cf09308f-4549-447c-b208-c256bce530f3">Message Set ID</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_12ef7603-249b-41b9-9bb6-8175e1a8922b">MessageSetID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ee41fc6b-fd96-4a0c-8a59-e6021549153b">SH</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_61e7389d-89b1-4cdc-802a-5e8d46870f04">1</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_ac074797-9dc9-4473-b957-b4841daa5e26">(0000,5020)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9c5484e4-30cb-4aa3-8797-6ecdff8978cc">End Message ID</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_43b06c87-e0d3-4722-b4a0-fd4d67886fd4">EndMessageID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_135b3d1c-e00d-418e-995f-2df9da8bbd13">SH</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a5754dc8-4728-4284-9e3f-a76bc286e7fc">1</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_1e6631aa-92de-4004-b497-6d79f5927cf1">(0000,5110)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_fa523a64-a65a-4cba-9de8-04952163ad7c">Display Format</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_42ceb578-4c5e-4c67-b30e-417aec316e75">DisplayFormat</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_f0fc5910-9ab1-4861-933c-1a588012274b">LT</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5452f50c-628d-476a-a16e-7cf822d0cb82">1</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_22f3f711-71da-4ba3-8cf2-be413c1d7e4f">(0000,5120)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_adcabfb4-dda6-4a64-9200-ee5c36221266">Page Position ID</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_284651d7-a401-42e4-bc42-c4b0bf7ebe2b">PagePositionID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_b804dcad-46e7-47f0-b374-01a198c81681">LT</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_09d06530-f1a7-4681-bba7-08505872ed73">1</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_403e8e6c-cf04-4036-bde8-315bc0c7f7ae">(0000,5130)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_9e5bd33b-f8df-4dae-99ba-54b6396bbb98">Text Format ID</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_64382e16-2aac-4fa2-8192-00ba6af9668d">TextFormatID</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_e342d1bd-3a3a-4548-b388-b726a72ff943">CS</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_32a7d2cc-7211-4e26-9cbd-23396e5ecaf3">1</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a9aabfd6-0fd3-4e2d-8fe8-03d1d42946b1">(0000,5140)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_c909c378-5bf1-4e3b-8c48-7549f4a2d30f">Normal/Reverse</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_833d37b5-1253-4656-88dc-7993d1293785">NormalReverse</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_97cd484d-1bbf-48a2-9942-0a111b9186b4">CS</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_df72f13c-5262-45c4-a64f-ea30d9c800e6">1</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_8fb20155-60bb-488c-a63a-b3a2472c8799">(0000,5150)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e7c9c2c7-d130-4965-81a6-f661a79a183e">Add Gray Scale</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_4c58740d-fd5b-4a3f-9164-4748374c98ad">AddGrayScale</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_5202a818-2456-4659-bd8a-f3208f62959e">CS</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_fb863f1e-4638-4414-852e-f67ca8852963">1</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_850207dd-5d0f-439d-918e-8ff057c52eb2">(0000,5160)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_a064fd4a-bb25-4103-930f-9100b0ea5f3d">Borders</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_d678ddb8-40af-4f70-b849-da7d843b2732">Borders</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_91fff9f3-4282-43c0-93d6-ba68bc74b7c1">CS</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d80afee5-0f95-4f75-b706-b0bb63da6932">1</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_16f2ae89-76f1-4bca-81c4-6a926d07e9a6">(0000,5170)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_ad847ffc-8c28-4d84-ae85-0bcdee76d596">Copies</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_48cfa0fe-d73b-4058-a4c5-b5cd9bd3faee">Copies</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d79b730c-1f97-4810-83d4-14b629573a32">IS</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_221ffb8a-3a11-42f0-a0aa-b107d1769760">1</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a6c89f52-f229-4094-879a-b17b989e0cfc">(0000,5180)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6b3fb079-55d4-4829-8a0f-d1c44fa94110">Command Magnification Type</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_01bc7560-e36e-4a00-8725-5c099b8fb6f5">CommandMagnificationType</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_244fea60-e5b7-464a-a9d1-1e047b3d416b">CS</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_df998b12-2425-46fd-874b-6d6a89277a3a">1</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6d562b10-b5ea-40d1-a920-97926e052720">(0000,5190)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_be065eef-55c2-41b5-887a-9d65b59503cf">Erase</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e89e7b42-a71d-4371-bac6-dd97018510c4">Erase</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_aabcadd7-f93f-4a52-868d-8cd7224b1bf7">CS</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_58078088-3a98-47d6-ab7e-1137086f4ddb">1</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_a2ee2df9-f7a6-43f6-8f73-10874234e57d">(0000,51A0)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_f4f1a57d-43b7-4d34-bbc1-e3cd5198af8a">Print</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b1211181-13b3-4311-a80f-c64c5874c405">Print</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_4e1156ea-fd80-44d8-8c16-83c16451d064">CS</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_c2fd3783-2364-4ce6-89d5-e72ba15bb95e">1</para>
      </td>
    </tr>
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_d85c6457-d6c0-4e3b-8f67-3814e6b688f2">(0000,51B0)</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_6c3c5965-a068-4585-bfc6-7c3041fc4793">Overlays</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_e92acfce-5e03-4692-b1a5-b565d5548c35">Overlays</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_6f163844-e9f8-4a58-ae7f-740e63716f72">US</para>
      </td>
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="para_65a1e9b0-87ff-4820-9d6f-db76b0a77ecb">1-n</para>
      </td>
    </tr>
   </tbody>
  </table>


  <note>
    <para xml:id="para_6bc4ccd5-d3d0-4415-9c0e-4c7259e6e385">For attributes that were present in ACR-NEMA 1.0 and 2.0 and that have been retired, the specifications of Value Representation and Value Multiplicity provided are recommendations for the purpose of interpreting their values in objects created in accordance with earlier editions of this Standard. These recommendations are suggested as most appropriate for a particular attribute; however, there is no guarantee that historical objects will not violate some requirements or specified VR and/or VM.</para>
  </note>
  
  </section>
</chapter>
<chapter label="F" status="1" xml:id="chapter_F">
    <title>Usage of the P-DATA Service By the DICOM Application Entity (Normative)</title>
  
  <para xml:id="para_0da63733-85d0-41e6-922f-b21d3652b36a">How DICOM messages are encapsulated into the P-DATA Service by the DICOM Application Entity is specified in <olink targetdoc="PS3.8" targetptr="PS3.8" xrefstyle="select: labelnumber"/>.</para>
  <note>
    <para xml:id="para_1a585e72-1b4d-469c-ac69-6a2af824fc71">Identical text to that in <olink targetdoc="PS3.8" targetptr="PS3.8" xrefstyle="select: labelnumber"/> was formerly duplicated here.</para>
  </note>
</chapter>