DICOM PS3.20 2026d - Imaging Reports using HL7 Clinical Document Architecture

C.4.3 Content Item Mapping

Each Content Item immediately subsidiary to a section CONTAINER shall be mapped to the corresponding entry level template, and shall be included subsidiary to the associated CDA section or subsection. This is in addition to its rendering in the section/text narrative block.

Coded concepts that are encoded in the SR using with the Coding Scheme Designator "SRT" shall be mapped to the equivalent SNOMED CT code. Mappings for value sets invoked in both SR and CDA are provided in PS3.16.

C.4.3.1 Coded Observations

SR CODE Content Items shall be mapped to Coded Observation entries.

Table C.4-6. CDA Coded Observation mapping from SR CODE

CDA Business Name

DICOM SR

CodedObservation[*]: ObsName

Concept Name Code Sequence (0040,A043)

CodedObservation[*]: ObsValue

Concept Code Sequence (0040,A168)

CodedObservation[*]: Time

Observation DateTime (0040,A032)

CodedObservation[*]: InterpretationCode

CodedObservation[*]: ActionableFindingCode

CodedObservation[*]: TargetSite

(363698007, SCT, "Finding Site")

CodedObservation[*]:Laterality

(363698007, SCT, "Finding Site") > (272741003, SCT, "Laterality")

CodedObservation[*]:TopoModifier

CodedObservation[*]:Method

CodedObservation[*]: SOPInstance

[See C.4.3.3]

CodedObservation[*]: QuantityMeasurement

[See C.4.3.4]

CodedObservation[*]: CodedObservation


The CODE observations in TID 2002 do not specifically include finding site, laterality, and topographical modifiers, but these modifiers are not forbidden in the template, and may be present in a SR SOP Instance being transformed to CDA.

DICOM PS3.20 2026d - Imaging Reports using HL7 Clinical Document Architecture