DICOM PS3.20 2022b - Imaging Reports using HL7 Clinical Document Architecture |
---|
The Procedure Technique entry allows the encoding of various parameters of the image acquisition. Other details may be found in other entries (e.g., procedural medication). |
|
Included in 9.3 Imaging Procedure Description and 9.4 Comparison Study |
|
ValueSet CID 29 “Acquisition Modality” |
||||||||
ValueSet CID 244 “Laterality” |
||||||||
Example 10.4-1. Procedure Technique template example
<procedure moodCode="EVN" classCode="PROC"> <templateId root="1.2.840.10008.9.14"/> <id root="1.2.840.6544.33.9100653988998717.997527582345600170"/> <code code="RPID465" displayName="MR NECK ANGIOGRAPHY" codeSystem="2.16.840.1.113883.6.256" codeSystemName="RadLex"/> <text><reference value="#proc"/></text> <effectiveTime value="20140913222400"/> <methodCode code="MR" displayName="Magnetic Resonance" codeSystem="1.2.840.10008.2.16.4" codeSystemName="DCM"/> <targetSiteCode code="45048000" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED CT" displayName="Neck (structure)"> </targetSiteCode> </procedure>
DICOM PS3.20 2022b - Imaging Reports using HL7 Clinical Document Architecture |
---|