DICOM PS3.18 2026a - Web Services

B.41 Bi-directional Proxies For Searching The Modality Scheduled Procedure Steps

The DICOMweb Modality Scheduled Procedure Step Service may be deployed in a hybrid environment, i.e., an environment in which both DICOMweb and DIMSE are used. In such a hybrid environment, a proxy can broker Transactions from one service to the other, allowing a DICOMweb origin server or a DIMSE SCP to support workflow primitives for a mixed set of DICOMweb user agents and DIMSE SCUs.

DICOM does not require an implementation of proxies; however, since they would be very useful in a hybrid environment, the examples in this section show how this could be done.

Figure B.41-1 shows how a proxy could facilitate a request for searching modality scheduled procedure steps from a DIMSE SCU to a DICOMweb origin server.

Modality Scheduled Procedure Step DIMSE Proxy for DICOMweb Origin Server

Figure B.41-1. Modality Scheduled Procedure Step DIMSE Proxy for DICOMweb Origin Server


Figure B.41-2 shows how a proxy could facilitate a request for searching modality scheduled procedure steps from a DICOMweb user agent to a DIMSE SCP.

Modality Scheduled Procedure Step DICOMweb Proxy for DIMSE SCP

Figure B.41-2. Modality Scheduled Procedure Step DICOMweb Proxy for DIMSE SCP


DICOM PS3.18 2026a - Web Services