DICOM PS3.18 2026d - Web Services

F.4 DICOM JSON Model Example

// The following example is a QIDO-RS SearchForStudies response consisting 
// of two matching studies, corresponding to the example QIDO-RS request:
// GET http://qido.nema.org/studies?PatientID=12345&includefield=all&limit=2
[
    {   // Result 1
        "00080005": {
            "vr": "CS",
            "Value": [ "ISO_IR 192" ]
        },
        "00080020": {
            "vr": "DA",
            "Value": [ "20130409" ]
        },
        "00080030": {
            "vr": "TM",
            "Value": [ "131600.0000" ]
        },
        "00080050": {
            "vr": "SH",
            "Value": [ "11235813" ]
        },
        "00080056": {
            "vr": "CS",
            "Value": [ "ONLINE" ]
        },
        "00080061": {
            "vr": "CS",
            "Value": [
                "CT",
                "PET"
            ]
        },
        "00080090": {
            "vr": "PN",
            "Value": [
              {
                "Alphabetic": "^Bob^^Dr."
              }
            ]
        },
        "00081190": {
            "vr": "UR",
            "Value": [ "http://wado.nema.org/studies/
            1.2.392.200036.9116.2.2.2.1762893313.1029997326.945873" ]
        },
        "00090010": {
            "vr": "LO",
            "Value": [ "Vendor A" ]
        },
        "00091002": {
            "vr": "UN",
            "InlineBinary": "z0x9c8v7"
        },
        "00100010": {
            "vr": "PN",
            "Value": [
              {
                "Alphabetic": "Wang^XiaoDong",
                "Ideographic": "王^小東"
              }
            ]
        },
        "00100020": {
            "vr": "LO",
            "Value": [ "12345" ]
        },
        "00100021": {
            "vr": "LO",
            "Value": [ "Hospital A" ]
        },
        "00100030": {
            "vr": "DA",
            "Value": [ "19670701" ]
        },
        "00100040": {
            "vr": "CS",
            "Value": [ "M" ]
        },
        "00101002": {
            "vr": "SQ",
            "Value": [
                {
                    "00100020": {
                        "vr": "LO",
                        "Value": [ "54321" ]
                    },
                    "00100021": {
                        "vr": "LO",
                        "Value": [ "Hospital B" ]
                    }
                },
                {
                    "00100020": {
                        "vr": "LO",
                        "Value": [ "24680" ]
                    },
                    "00100021": {
                        "vr": "LO",
                        "Value": [ "Hospital C" ]
                    }
                }
            ]
        },
        "0020000D": {
            "vr": "UI",
            "Value": [ "1.2.392.200036.9116.2.2.2.1762893313.1029997326.945873" ]
        },
        "00200010": {
            "vr": "SH",
            "Value": [ "11235813" ]
        },
        "00201206": {
            "vr": "IS",
            "Value": [ 4 ]
        },
        "00201208": {
            "vr": "IS",
            "Value": [ 942 ]
        }
    },
    {   // Result 2
        "00080005": {
            "vr": "CS",
            "Value": [ "ISO_IR 192" ]
        },
        "00080020": {
            "vr": "DT",
            "Value": [ "20130309" ]
        },
        "00080030": {
            "vr": "TM",
            "Value": [ "111900.0000" ]
        },
        "00080050": {
            "vr": "SH",
            "Value": [ "11235821" ]
        },
        "00080056": {
            "vr": "CS",
            "Value": [ "ONLINE" ]
        },
        "00080061": {
            "vr": "CS",
            "Value": [
                "CT",
                "PET"
            ]
        },
        "00080090": {
            "vr": "PN",
            "Value": [
              {
                "Alphabetic": "^Bob^^Dr." 
              }
            ]
        },
        "00081190": {
            "vr": "UR",
            "Value": [ "http://wado.nema.org/studies/
            1.2.392.200036.9116.2.2.2.2162893313.1029997326.945876" ]
        },
        "00090010": {
            "vr": "LO",
            "Value": [ "Vendor A" ]
        },
        "00091002": {
            "vr": "UN",
            "InlineBinary": "z0x9c8v7"
        },
        "00100010": {
            "vr": "PN",
            "Value": [
              {
                "Alphabetic": "Wang^XiaoDong",
                "Ideographic": "王^小東" 
              }
            ]
        },
        "00100020": {
            "vr": "LO",
            "Value": [ "12345" ]
        },
        "00100021": {
            "vr": "LO",
            "Value": [ "Hospital A" ]
        },
        "00100030": {
            "vr": "DA",
            "Value": [ "19670701" ]
        },
        "00100040": {
            "vr": "CS",
            "Value": [ "M" ]
        },
        "00101002": {
            "vr": "SQ",
            "Value": [
                {
                    "00100020": {
                        "vr": "LO",
                        "Value": [ "54321" ]
                    },
                    "00100021": {
                        "vr": "LO",
                        "Value": [ "Hospital B" ]
                    }
                },
                {
                    "00100020": {
                        "vr": "LO",
                        "Value": [ "24680" ]
                    },
                    "00100021": {
                        "vr": "LO",
                        "Value": [ "Hospital C" ]
                    }
                }
            ]
        },
        "0020000D": {
            "vr": "UI",
            "Value": [ "1.2.392.200036.9116.2.2.2.2162893313.1029997326.945876" ]
        },
        "00200010": {
            "vr": "SH",
            "Value": [ "11235821" ]
        },
        "00201206": {
            "vr": "IS",
            "Value": [ 5 ]
        },
        "00201208": {
            "vr": "IS",
            "Value": [ 1123 ]
        }
    }
]
DICOM PS3.18 2026d - Web Services