DICOM PS3.18 2026d - Web Services
8.3.5.3.7 Viewpoint Up

The "viewpointup" parameter specifies the vertical orientation of the camera within the Viewpoint Coordinate System (VCS). See Section C.11.30.1 in PS3.3.

The syntax of this parameter is:

%s"viewpointup =" ux "," uy "," uz

Where

ux, uy and uz

Viewpoint up direction (i.e., the direction that the top of the camera is pointing to). A vector (x,y,z) in the VCS.

Note

This corresponds to the Viewpoint Up Direction (0070,1605) attribute. See Section C.11.30 in PS3.3.

If the Target Resource is a Volumetric Presentation Stateand any orientation Query Parameters are present, the origin server shall apply the query parameter(s) instead of the geometry attributes in the Multi-Planar Reconstruction Geometry Module, or the Volume Render Geometry Module.