DICOM PS3.18 2025e - Web Services
8.3.5.3.2 Match

The "match" parameter specifies common DICOM Attribute/Value pair characteristics of the Volume Data.

When the user agent identifies a Target Resource that is a superset of the intended Volume Data, it may identify Attribute/Value pairs that specify matching criteriato identify specific Instances or Frames in the Target Resource to resample as Volume Data. The resulting subset shall conform to the Volume Input Requirements for Rendered MPR Volume Resources and Rendered 3D Volume Resources (see Section C.11.23.1 in PS3.3).

See Section 8.3.4.1 for the syntax of this parameter.

The user agent may include the following Attributes in the parameter:

The origin server shall reconstruct Volume Data meeting the Volume Input Criteria.

The origin server shall return a 400 (Bad Request), and may include an appropriate Status Report, if any of the following are true:

DICOM PS3.18 2025e - Web Services