DICOM PS3.17 2024b - Explanatory Information

WWWW.2 Application of the templates describing multiparametric MRI acquisition

This example demonstrates the use of TID 1600 “Image Library” within TID 4300 “Prostate Multiparametric MR Imaging Report” (Row 6). Note that Diffusion weighted acquisition image library group (rows 1.2.*) could be split into separate groups corresponding to the individual b-values.

Table WWWW.2-1. Application of the templates describing multiparametric MRI acquisition

Node

Code Meaning of Concept Name

Code Meaning or Example Value

TID

1

Image Library

TID 1600

1.1

Image Library Group

TID 1600

1.1.1

Modality

MR

TID 1602

1.1.2

Magnetic field strength

3 T

TID 1606

1.1.3

MR coil

Endorectal coil

TID 1606

CID 6349

1.1.4

MR signal intensity

T2 Weighted MR Signal Intensity

TID 1606

CID 6311

1.1.5

Cross-sectional scan plane orientation

Axial

TID 1606

CID 6312

1.1.6

IMAGE

TID 1601

1.1.n

IMAGE

TID 1601

1.2

Image Library Group

TID 1600

1.2.1

Modality

MR

TID 1602

1.2.2

Magnetic field strength

3 T

TID 1606

1.2.3

MR coil

Endorectal coil

TID 1606

CID 6349

1.2.4

MR signal intensity

Diffusion weighted

TID 1606

CID 6311

1.2.5

Cross-sectional scan plane orientation

Axial

TID 1606

CID 6312

1.2.6

Source image diffusion b-value

0 s/mm2

TID 1606

1.2.7

IMAGE

TID 1601

1.2.n

IMAGE

TID 1601

1.3

Image Library Group

TID 1600

1.3.1

Modality

MR

TID 1602

1.3.2

Magnetic field strength

3 T

TID 1606

1.3.3

MR coil

Endorectal coil

TID 1606

1.3.4

MR signal intensity

Diffusion weighted

TID 1606

CID 6311

1.3.5

Cross-sectional scan plane orientation

Axial

TID 1606

CID 6312

1.3.6

Source image diffusion b-value

500 s/mm2

TID 1606

1.3.7

IMAGE

TID 1601

1.3.n

IMAGE

TID 1601

1.4

Image Library Group

TID 1600

1.4.1

Modality

MR

TID 1602

1.4.2

Magnetic field strength

3 T

TID 1606

1.4.3

MR coil

Endorectal coil

TID 1606

1.4.4

MR signal intensity

Dynamic Contrast-Enhanced Acquisition

TID 1606

CID 6311

1.4.5

Cross-sectional scan plane orientation

Axial

TID 1606

CID 6312

1.4.6

Prostate DCE temporal resolution

3.5 s

TID 1608

1.4.7

IMAGE

TID 1601

1.4.n

IMAGE

TID 1601


DICOM PS3.17 2024b - Explanatory Information