DICOM PS3.17 2021e - Explanatory Information

TTTT.3.2.3 Potential workflow for the display of lesion tracking

Steps:

  1. A user displays a dermoscopic study on image display / evidence creator actor, and invokes the opening of the lesion tracking reporting window, which invokes a DICOM query / retrieve of all individual DICOM Structured Report Measurement Reports for that patient that meet a criterion (e.g., (121058, DCM, "Procedure reported") = (446078004, SCT, "Dermoscopic photograph")).

  2. The lesion tracking reporting window displays images and measurements and derived measurements from one or more DICOM Structured Report objects in the lesion tracking reporting window (see Figure TTTT.3-4).

  3. The lesion tracking reporting windows may display summary information (e.g., change in size tables or graphs).

Potential Lesion Tracking Reporting Window Display

Figure TTTT.3-4. Potential Lesion Tracking Reporting Window Display


DICOM PS3.17 2021e - Explanatory Information