DICOM PS3.17 2024b - Explanatory Information

N.3.5 Left Ventricle Output

Name of ASE Concept

Base Measurement Concept Name

Concept or Acquisition Context Modifiers

Left Ventricular Stroke Volume

(90096001, SCT, "Stroke Volume")

Left Ventricular Stroke Volume by Doppler Volume Flow

(90096001, SCT, "Stroke Volume")

(370129005, SCT, "Measurement Method") = (125219, DCM, "Doppler Volume Flow") (363698007, SCT, "Finding Site") = (13418002, SCT, "Left Ventricle Outflow Tract")

Left Ventricular Stroke Volume by Teichholz Method

(90096001, SCT, "Stroke Volume")

(370129005, SCT, "Measurement Method") = (125209, DCM, "Teichholz")

Left Ventricular Stroke Volume by 2-D Single Plane by Method of Disks (4-Chamber)

(90096001, SCT, "Stroke Volume")

(1110321 DCM, "Image View")= (399214001, SCT, "Apical Four Chamber") (370129005, SCT, "Measurement Method") = (125208, DCM, "Method of Disks, Single Plane")

Left Ventricular Stroke Volume by 2-D Biplane by Method of Disks

(90096001, SCT, "Stroke Volume")

(370129005, SCT, "Measurement Method") = (125207, DCM, "Method of Disks, Biplane")

Left Ventricular Cardiac Output

(82799009, SCT, "Cardiac Output")

Left Ventricular Cardiac Output by Doppler Volume Outflow

(82799009, SCT, "Cardiac Output")

(370129005, SCT, "Measurement Method") = (125219, DCM, "Doppler Volume Flow") (363698007, SCT, "Finding Site") = (13418002, SCT, "Left Ventricle Outflow Tract")

Left Ventricular Cardiac Output by Teichholz Method

(82799009, SCT, "Cardiac Output")

(370129005, SCT, "Measurement Method") = (125209, DCM, "Teichholz")

Left Ventricular Cardiac Output by 2-D Single Plane by Method of Disks (4-Chamber)

(82799009, SCT, "Cardiac Output")

(111031, DCM, "Image View") = (399214001, SCT, "Apical Four Chamber") (370129005, SCT, "Measurement Method") = (125208, DCM, "Method of Disks, Single Plane")

Left Ventricular Cardiac Output by 2-D Biplane by Method of Disks

(82799009, SCT, "Cardiac Output")

(370129005, SCT, "Measurement Method") = (125207, DCM, "Method of Disks, Biplane")

Left Ventricular Cardiac Index

(54993008, SCT, "Cardiac Index")

Left Ventricular Cardiac Index by Doppler Volume Flow

(54993008, SCT, "Cardiac Index")

(370129005, SCT, "Measurement Method") = (125219, DCM, "Doppler Volume Flow")

Left Ventricular Cardiac Index by Teichholz Method

(54993008, SCT, "Cardiac Index")

(370129005, SCT, "Measurement Method") = (125209, DCM, "Teichholz")

Left Ventricular Cardiac Index by 2-D Single Plane by Method of Disks (4-Chamber)

(54993008, SCT, "Cardiac Index")

(111031, DCM, "Image View") = (399214001, SCT, "Apical Four Chamber") (370129005, SCT, "Measurement Method") = (125208, DCM, "Method Of Disks, Single Plane")

Left Ventricular Cardiac Index by 2-D Biplane by Method of Disks

(54993008, SCT, "Cardiac Index")

(370129005, SCT, "Measurement Method") = (125207, DCM, "Method of Disks, Biplane")

Note

Measurements in the Left Ventricle section have context of Left Ventricle and do not require a Finding Site modifier (363698007, SCT, "Finding Site") = (87878005, SCT, "Left Ventricle") to specify the site. The Finding Site modifier appears for more specificity.

DICOM PS3.17 2024b - Explanatory Information