DICOM PS3.17 2022b - Explanatory Information

N.3.10 Pulmonary Vein

Name of ASE Concept

Base Measurement Concept Name

Concept or Acquisition Context Modifiers

Pulmonary Vein Systolic Peak Velocity

(29450-4, LN, "Pulmonary Vein Systolic Peak Velocity")

Pulmonary Vein Diastolic Peak Velocity

(29451-2, LN, "Pulmonary Vein Diastolic Peak Velocity")

Pulmonary Vein Systolic to Diastolic Ratio

(29452-0, LN, "Pulmonary Vein Systolic to Diastolic Ratio")

Pulmonary Vein Atrial Contraction Reversal Peak Velocity

(29453-8, LN, "Pulmonary Vein Atrial Contraction Reversal Peak Velocity")

Right Upper Pulmonary Vein Peak Systolic Velocity

(29450-4, LN, "Pulmonary Vein Systolic Peak Velocity")

(106233006, SCT, "Topographical Modifier") = (255499006, SCT, "Right Upper Segment")

Right Upper Pulmonary Vein Diastolic Peak Velocity

(29451-2, LN, "Pulmonary Vein Diastolic Peak Velocity")

(106233006, SCT, "Topographical Modifier") = (255499006, SCT, "Right Upper Segment")

Right Upper Pulmonary Vein Systolic to Diastolic Velocity Ratio

(29452-0, LN, "Pulmonary Vein Systolic to Diastolic Ratio")

(106233006, SCT, "Anatomic Site Modifier") = (255499006, SCT, "Right Upper Segment")

Right Lower Pulmonary Vein Peak Systolic Velocity

(29450-4, LN, "Pulmonary Vein Systolic Peak Velocity")

(106233006, SCT, "Topographical Modifier") = (255496004, SCT, "Right Lower Segment")

Right Lower Pulmonary Vein Diastolic Peak Velocity

(29451-2, LN, "Pulmonary Vein Diastolic Peak Velocity")

(106233006, SCT, "Topographical Modifier") = (255496004, SCT, "Right Lower Segment")

Right Lower Pulmonary Vein Systolic to Diastolic Velocity Ratio

(29452-0, LN, "Pulmonary Vein Systolic to Diastolic Ratio")

(106233006, SCT, "Topographical Modifier") = (255496004, SCT, "Right Lower Segment")

Left Upper Pulmonary Vein Peak Systolic Velocity

(29450-4, LN, "Pulmonary Vein Systolic Peak Velocity")

(106233006, SCT, "Topographical Modifier") = (255482005, SCT, "Left Upper Segment")

Left Upper Pulmonary Vein Velocity Peak Diastolic

(29451-2, LN, "Pulmonary Vein Diastolic Peak Velocity")

(106233006, SCT, "Topographical Modifier") = (255482005, SCT, "Left Upper Segment")

Left Upper Pulmonary Vein Systolic to Diastolic Velocity Ratio

(29452-0, LN, "Pulmonary Vein Systolic to Diastolic Ratio")

(106233006, SCT, "Topographical Modifier") = (255482005, SCT, "Left Upper Segment")

Left Lower Pulmonary Vein Peak Systolic Velocity

(29450-4, LN, "Pulmonary Vein Systolic Peak Velocity")

(106233006, SCT, "Topographical Modifier") = (264068005, SCT, "Left Lower Segment")

Left Lower Pulmonary Vein Diastolic Peak Velocity

(29451-2, LN, "Pulmonary Vein Diastolic Peak Velocity")

(106233006, SCT, "Topographical Modifier") = (264068005, SCT, "Left Lower Segment")

Left Lower Pulmonary Vein Systolic to Diastolic Velocity Ratio

(29452-0, LN, "Pulmonary Vein Systolic to Diastolic Ratio")

(106233006, SCT, "Topographical Modifier") = (264068005, SCT, "Left Lower Segment")

DICOM PS3.17 2022b - Explanatory Information