DICOM PS3.17 2024e - Explanatory Information

XXX.3.10.3 Encoding Details

XXX.3.10.3.1 Volume Presentation State Relationship Module Recommendations

Table XXX.3.10.3.1-1. Volume Presentation State Relationship Module Recommendations

Attribute Name

Tag

Comment

Volumetric Presentation Input Set Sequence

(0070,120A)

Item #1

>Volumetric Presentation Input Set UID

(0070,1209)

Set to UID1

>Presentation Input Type

(0070,1202)

Set to VOLUME

>Referenced Image Sequence

(0008,1140)

Reference to CT volume

Volumetric Presentation State Input Sequence

(0070,1201)

Item #1

>Volumetric Presentation Input Number

(0070,1207)

Set to 1

>Volumetric Presentation Input Set UID

(0070,1209)

Set to UID1, referencing the first item in the Volumetric Presentation Input Set Sequence (0070,120A)

>Include VOI LUT Macro Table C.11-2B

Set to identity

>Crop

(0070,1204)

Set to NO


DICOM PS3.17 2024e - Explanatory Information