DICOM PS3.17 2026c - Explanatory Information

LLL.2.2 Presentation States

LLL.2.2.1 Presentation State Referencing Classic Image That Contains The First Slice

Nesting

Attribute

Tag

VR

VL (hex)

Value

Specific Character Set

(0008,0005)

CS

000a

ISO_IR 100

SOP Class UID

(0008,0016)

UI

001c

1.2.840.10008.5.1.4.1.1.11.1

SOP Instance UID

(0008,0018)

UI

0038

1.2.276.0.7230010.3.1.4.2989371993.3196.1272478982.1246

Study Date

(0008,0020)

DA

0008

20061230

Study Time

(0008,0030)

TM

0006

100000

Accession Number

(0008,0050)

SH

0010

2263295914110886

Modality

(0008,0060)

CS

0002

PR

Manufacturer

(0008,0070)

LO

0000

Referring Physician's Name

(0008,0090)

PN

0000

Referenced Series Sequence

(0008,1115)

SQ

ffffffff

%item

Referenced Image Sequence

(0008,1140)

SQ

ffffffff

%item

Referenced SOP Class UID

(0008,1150)

UI

001a

1.2.840.10008.5.1.4.1.1.2

Referenced SOP Instance UID

(0008,1155)

UI

003c

1.3.6.1.4.1.9328.50.1.​21169049221871725649891126757390969029

%enditem

%endseq

Series Instance UID

(0020,000e)

UI

003e

1.3.6.1.4.1.9328.50.1.​160525591228102999616019562758104412505

%enditem

%endseq

Patient's Name

(0010,0010)

PN

0008

277654^

Patient ID

(0010,0020)

LO

0010

RIDER-2357766186

Patient's Birth Date

(0010,0030)

DA

0008

19301018

Patient's Sex

(0010,0040)

CS

0000

Patient Identity Removed

(0012,0062)

CS

0004

YES

De-identification Method

(0012,0063)

LO

002a

CTP: DICOM-S142-Baseline: 20090627:021422

Body Part Examined

(0018,0015)

CS

0006

CHEST

Study Instance UID

(0020,000d)

UI

003e

1.3.6.1.4.1.9328.50.1.​331429121990566779475389049484716775937

Series Instance UID

(0020,000e)

UI

0038

1.2.276.0.7230010.3.1.3.2989371993.3196.1272478982.1245

Study ID

(0020,0010)

SH

0004

1234

Series Number

(0020,0011)

IS

0002

1

Instance Number

(0020,0013)

IS

0002

1

Rescale Intercept

(0028,1052)

DS

0006

-1024

Rescale Slope

(0028,1053)

DS

0002

1

Rescale Type

(0028,1054)

LO

0002

US

Softcopy VOI LUT Sequence

(0028,3110)

SQ

ffffffff

%item

Window Center

(0028,1050)

DS

0008

-600

Window Width

(0028,1051)

DS

0004

1200

%enditem

%endseq

Displayed Area Selection Sequence

(0070,005a)

SQ

ffffffff

%item

Displayed Area Top Left Hand Corner

(0070,0052)

SL

0008

000000b3,000000c9

Displayed Area Bottom Right Hand Corner

(0070,0053)

SL

0008

0000018c,000001a2

Presentation Size Mode

(0070,0100)

CS

0008

MAGNIFY

Presentation Pixel Spacing

(0070,0101)

DS

0012

0.732422\0.732422

Presentation Pixel Magnification Ratio

(0070,0103)

FL

0004

2.36742

%enditem

%endseq

Content Label

(0070,0080)

CS

0008

UNNAMED

Content Description

(0070,0081)

LO

0000

Presentation Creation Date

(0070,0082)

DA

0008

20100428

Presentation Creation Time

(0070,0083)

TM

0006

142302

Content Creator's Name

(0070,0084)

PN

0000

Presentation LUT Shape

(2050,0020)

CS

0008

IDENTITY

DICOM PS3.17 2026c - Explanatory Information