| DICOM PS3.17 2026c - Explanatory Information |
|---|
The HL7 Implementation Guides have imaging order examples of FHIR, V2, and CDA documents with their gender model encodings. These can be found at:
http://hl7.org/xprod/ig/uv/gender-harmony/informative1/v2dicom_use_case.html
These might be mapped onto the DICOM Patient and Patient Study Module attributes as shown below. These mappings are just illustrative.
The following HL7 v2.9.1 message is an order for a "PET Myocardial Perfusion, Rest and Stress" imaging procedure.
The administrative sex is female based on prior admissions. The patient was given a gender of female at birth in 1978. At admission on July 15, 2022, the patient informed the admitting staff that they now identify as male and are taking hormonal treatment.
The PET imaging procedure uses creatinine reference ranges to determine details of the procedure. Creatinine reference ranges are sex related. Hormonal treatment for gender changes also affects creatinine reference ranges. At this hospital the medical protocol for patients taking hormonal treatment is to use affirmed gender creatinine reference ranges.
The Sex Parameters for Clinical Use category (SPCU) for the current procedure is set as Male-typical, with the comment that due to hormonal treatment Male-typical creatinine reference ranges should be used. The SPCU at birth is also provided in the order for use by equipment that might find that useful (the SPCU at birth is not needed by the PET/CT system but might be needed by subsequent analysis systems.)
Note that the HL7 model does not specify how the effective start and stop datetimes are chosen. That is left to the local policies and procedures. DICOM systems will usually obtain these from the HL7 messages and are unlikely to modify them.
MSH|^~\&|||||20220715142240||OMI^O23|WSA5mY0UBuCGrytRTAFR8UWJ|P|2.9.1
PID|||patientID^^^^MR||Smith^Janet^^^^^B~Smith^John^^^^^N||19780328000000|F
GSP|1|S||76691-5^Gender identity^LN|446151000124109^Identifies as male gender^SCT|20220715010000
GSC|1|S||Male-typical^Male typical parameters^SexParameterForClinicalUse||OBR^4|20220715090000|
Due to hormonal treatment, use Male-typical Creatinine reference ranges
GSC|2|S||Female-typical^Female typical parameters^SexParameterForClinicalUse|197803280000^20220715090000|
OBR^4||Sex at Birth
ORC|NW
OBR||||241439007^PET heart study^SCT|||||||||||||||||||||||||||||||||||||||||82800-4^PET+CT Heart W contrast IV^LN
IPC|accessionNum|procedureID|studyInstanceUID|schProcedureStepId|
PT^Positron emission tomography^DCM|122793^PET Myocardial Perfusion, Rest and Stress^DCM
This message maps to DICOM Modality Worklist content as shown in Table FFFFF.4-1.
Table FFFFF.4-1. Mapping HL7 v2.9.1 OMI to DICOM Modality Worklist
| DICOM PS3.17 2026c - Explanatory Information |
|---|