Measurement Type = Direct
|
PV S-wave peak velocity
|
LN: 79917-1
|
(430757002, SCT, "Pulmonary Vein")
|
(20355-4, LN, "Peak Blood Velocity")
|
PW Dop
|
(444371003, SCT, "S-wave")
|
|
PV D-wave peak velocity
|
LN: 79916-3
|
Pulmonary Vein
|
Peak Blood Vel
|
PW Dop
|
D-wave
|
|
IVC S-wave peak velocity
|
DCM: 131062
|
Inferior Vena Cava
|
Peak Blood Flow
|
PW Dop
|
S-wave
|
|
Mitral valve annulus diameter
|
DCM: 131060
|
Mitral Valve Annulus
|
Diameter
|
2D
|
Diastole
|
|
Tricuspid valve annulus diameter
|
DCM: 131061
|
Tricuspid Valve Annulus
|
Diameter
|
2D
|
Diastole
|
|
Right ventricular inlet length
|
DCM: 131017
|
Right Ventricle
|
Length
|
2D
|
End Diastole
|
Method=Inlet Included
|
Left ventricular inlet length
|
DCM: 131018
|
Left Ventricle
|
Length
|
2D
|
End Diastole
|
Method=Inlet Included
|
Mitral a-wave peak velocity
|
LN: 80066-4
|
Mitral Valve
|
Peak Blood Vel
|
PW Dop
|
A-wave
|
|
Tricuspid a-wave peak velocity
|
LN: 79923-9
|
Tricuspid Valve
|
Peak Blood Vel
|
PW Dop
|
A-wave
|
|
IVC a-wave peak velocity
|
DCM: 131063
|
Inferior Vena Cava
|
Peak Blood Flow
|
PW Dop
|
A-wave
|
|
Mitral E-wave peak velocity
|
LN: 80070-6
|
Mitral Valve
|
Peak Blood Vel
|
PW Dop
|
E-wave
|
|
Tricuspid E-wave peak velocity
|
LN: 79925-4
|
Tricuspid Valve
|
Peak Blood Vel
|
PW Dop
|
E-wave
|
|
Mitral septal e' peak velocity
|
LN: 78185-6
|
Medial Mitral Annulus
|
Peak Tissue Vel
|
TDI
|
E-wave
|
|
Mitral septal a' peak velocity
|
LN: 81396-4
|
Medial Mitral Annulus
|
Peak Tissue Vel
|
TDI
|
A-wave
|
|
Mitral septal s' peak velocity
|
LN: 78187-2
|
Medial Mitral Annulus
|
Peak Tissue Vel
|
TDI
|
S-wave
|
|
Mitral lateral e' peak velocity
|
LN: 78186-4
|
Lateral Mitral Annulus
|
Peak Tissue Vel
|
TDI
|
E-wave
|
|
Mitral lateral a' peak velocity
|
LN: 81397-2
|
Lateral Mitral Annulus
|
Peak Tissue Vel
|
TDI
|
A-wave
|
|
Mitral lateral s' peak velocity
|
LN: 78188-0
|
Lateral Mitral Annulus
|
Peak Tissue Vel
|
TDI
|
S-wave
|
|
LVOT VTI
|
LN: 80030-0
|
LV Outflow Tract
|
VTI
|
PW Dop
|
Systole
|
Flow=Antegrade
|
RVOT VTI
|
LN: 80089-6
|
RV Outflow Tract
|
VTI
|
PW Dop
|
Systole
|
Flow=Antegrade
|
LV Stroke Volume
|
LN: 8769-2
|
Left Ventricle
|
Stroke Volume
|
PW Dop
|
Systole
|
Method=Doppler Volume Flow
|
RV Stroke Volume
|
LN: 8779-1
|
Right Ventricle
|
Stroke Volume
|
PW Dop
|
Systole
|
Method=Doppler Volume Flow
|
Left Ventricle Cardiac Output
|
LN: 8735-3
|
Left Ventricle
|
Cardiac Output
|
PW Dop
|
Systole
|
To index by fetal weight, Measurement Type would be Indexed, and Measurement Divisor would be Fetal Weight, the value of which would be recorded elsewhere.
|
Right Ventricle Cardiac Output
|
DCM: 131053
|
Right Ventricle
|
Cardiac Output
|
PW Dop
|
Systole
|
|
Combined Cardiac Output
|
DCM: 131054
|
Heart
|
Cardiac Output
|
PW Dop
|
Systole
|
|
Descending Aorta Diameter
|
LN: 18013-3
|
Descending Aorta
|
Diameter
|
B-mode
|
End Systole
|
|
UA Resistivity Index
|
LN: 12018-8
|
(50536004, SCT, "Umbilical artery")
|
Resistivity index
|
PW Dop
|
Full Cycle
|
Method = Free Cord Loop
|
Fetal ACA Resistivity Index
|
LN: 12012-1
|
(60176003, SCT, "Anterior Cerebral Artery")
|
Resistivity index
|
PW Dop
|
Full Cycle
|
|
Fetal MCA Resistivity Index
|
LN: 12014-7
|
(17232002, SCT, "Middle Cerebral Artery")
|
Resistivity index
|
PW Dop
|
Full Cycle
|
|
UA Pulsatility Index
|
LN: 12003-0
|
(50536004, SCT, "Umbilical artery")
|
Pulsatility Index
|
PW Dop
|
Full Cycle
|
Method = Free Cord Loop
|
MCA Pulsatility Index
|
LN: 11999-0
|
(17232002, SCT, "Middle Cerebral Artery")
|
Pulsatility Index
|
PW Dop
|
Full Cycle
|
|
DV Pulsatility Index in Veins
|
DCM: 131014
|
(367624001, SCT, "Ductus Venosus")
|
Pulsatility Index
|
PW Dop
|
Full Cycle
|
|
DV Peak Velocity Index in Veins
|
DCM: 131015
|
(367624001, SCT, "Ductus Venosus")
|
Peak Velocity Index
|
PW Dop
|
Full Cycle
|
|
PV VTI Forward
|
DCM: 131050
|
Pulmonary Vein
|
VTI
|
PW Dop
|
Full Cycle
|
Flow=Antegrade
|
PV VTI Reverse
|
DCM: 131051
|
Pulmonary Vein
|
VTI
|
PW Dop
|
A-Wave
|
Flow=Retrograde
|
Measurement Type = Ratio
|
PV VTIR/VTIF ratio
|
DCM: 131052
|
Pulmonary Vein
|
VTI
|
PW Dop
|
A-Wave
|
Measurement Divisor = PV VTI Forward
|
Mitral Septal E/e' ratio
|
LN: 78189-8
|
Mitral Valve
|
Peak Blood Vel
|
PW Dop
|
E-Wave
|
Measurement Divisor = Mitral Septal e' peak velocity
|
Mitral Lateral E/e' ratio
|
LN: 78190-6
|
Mitral Valve
|
Peak Blood Vel
|
PW Dop
|
E-Wave
|
Measurement Divisor = Mitral Lateral e' peak velocity
|
Cerebroplacental ratio
|
DCM: 131009
|
(17232002, SCT, "Middle Cerebral Artery")
|
Pulsatility Index
|
PW Dop
|
Full Cycle
|
Measurement Divisor = Umbilical Artery Pulsatility Index
|
Umbilicocerebral ratio
|
DCM: 131010
|
(50536004, SCT, "Umbilical artery")
|
Pulsatility Index
|
PW Dop
|
Full Cycle
|
Measurement Divisor = MCA Pulsatility Index
Method = Free Cord Loop Method
|
IVC preload index
|
DCM: 131011
|
Inferior Vena Cava
|
Peak Blood Vel
|
PW Dop
|
A-Wave
|
Flow=Retrograde (during numerator)
Measurement Divisor = IVC S-wave peak velocity
|
IVC S/a
|
DCM: 131012
|
Inferior Vena Cava
|
Peak Blood Vel
|
PW Dop
|
S-wave
|
Flow=Antegrade (during numerator)
Measurement Divisor = IVC a-wave peak velocity
|