DICOM PS3.16 2024c - Content Mapping Resource

TID 9007 General Relevant Patient Information

This Template collects a patient's relevant information for general purpose use. This Template, together with its subordinate Templates, describes the history of a patient's reproductive system, medications, substance use, environmental exposure, past procedures, risk factors, and indicated problems.

Table TID 9007. Parameters

Parameter Name

Parameter Usage

$ProblemList

Coded term or Context Group for value of Indicated Problem.

$RiskList

Coded term or Context Group for value of Risk List.


Type:

Extensible

Order:

Significant

Root:

No

Table TID 9007. General Relevant Patient Information

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (111517, DCM, "Relevant Patient Information")

1

M

2

>

HAS CONCEPT MOD

INCLUDE

DTID 1204 “Language of Content Item and Descendants”

1

MC

IFF TID 9007 is the Root Template for the Relevant Patient Information Query Service Class

3

>

CONTAINS

INCLUDE

DTID 3114 “Patient Assessment”

1

U

4

>

CONTAINS

INCLUDE

DTID 9002 “Medication, Substance, Environmental Exposure”

1

U

$ContainerConcept = EV (10160-0, LN, "History Of Medication Use")

$CodeConcept = EV (111516, DCM, "Medication Type")

5

>

CONTAINS

INCLUDE

DTID 9002 “Medication, Substance, Environmental Exposure”

1

U

$ContainerConcept = EV (111545, DCM, "Substance Use History")

$CodeConcept = EV (111546, DCM, "Used Substance Type")

$CodeValue = BCID 6089 “Substance”

6

>

CONTAINS

INCLUDE

DTID 9002 “Medication, Substance, Environmental Exposure”

1

U

$ContainerConcept = EV (111547, DCM, "Environmental Exposure History")

$CodeConcept = EV (111548, DCM, "Environmental Factor")

7

>

CONTAINS

INCLUDE

DTID 9003 “Previous Procedure”

1

U

$LateralityValue = BCID 244 “Laterality”

8

>

CONTAINS

INCLUDE

DTID 9004 “Indicated Problem”

1

U

$LateralityValue = BCID 244 “Laterality”

$ProblemList = $ProblemList

9

>

CONTAINS

INCLUDE

DTID 9005 “Risk Factor”

1

U

$RiskList = $RiskList

Defaults to BCID 6087 “General Risk Factor”

$FamilyList = DCID 7451 “Family Member”

10

>

CONTAINS

INCLUDE

DTID 9001 “Gynecological History”

1

U

11

>

CONTAINS

INCLUDE

DTID 9006 “Obstetric History”

1

U

12

>

CONTAINS

INCLUDE

DTID 3802 “Cardiovascular Patient History”

1

U

13

>

CONTAINS

INCLUDE

DTID 351 “Previous Reports”

1

U

14

>

CONTAINS

INCLUDE

DTID 4301 “Genitourinary Patient History”

1

U


Content Item Descriptions

Row 2

See Annex K.

Row 14

Genitourinary history is used to report findings such as those associated with the examinations that are suspicious for the presence of prostate cancer (i.e., Digital Rectal Examination, blood test results).