DICOM PS3.16 2022b - Content Mapping Resource

TID 5221 Cardiac Ultrasound Pediatric Echo Measurement Section

Type:

Extensible

Order:

Significant

Root:

No

Table TID 5221. Cardiac Ultrasound Pediatric Echo Measurement Section

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

INCLUDE

DTID 5222 “Pediatric, Fetal and Congenital Cardiac Ultrasound Section”

1-n

U

$SectionSubject = DCID 12282 “Cardiac Ultrasound Venous Return Systemic Finding Sites”

$MeasType = DCID 12264 “Cardiac Ultrasound Venous Return Systemic Measurements”

2

INCLUDE

DTID 5222 “Pediatric, Fetal and Congenital Cardiac Ultrasound Section”

1-n

U

$SectionSubject = DCID 12283 “Cardiac Ultrasound Venous Return Pulmonary Finding Sites”

$MeasType = DCID 12263 “Cardiac Ultrasound Venous Return Pulmonary Measurements”

3

INCLUDE

DTID 5222 “Pediatric, Fetal and Congenital Cardiac Ultrasound Section”

1-n

U

$SectionSubject = DCID 12284 “Cardiac Ultrasound Atria and Atrial Septum Finding Sites”

$MeasType = DCID 12265 “Cardiac Ultrasound Atria and Atrial Septum Measurements”

4

INCLUDE

DTID 5222 “Pediatric, Fetal and Congenital Cardiac Ultrasound Section”

1-n

U

$SectionSubject = DCID 12285 “Cardiac Ultrasound Atrioventricular Valves Finding Sites”

$MeasType = DCID 12268 “Cardiac Ultrasound Atrioventricular Valves Measurements”

5

INCLUDE

DTID 5222 “Pediatric, Fetal and Congenital Cardiac Ultrasound Section”

1-n

U

$SectionSubject = DCID 12286 “Cardiac Ultrasound Interventricular Septum Finding Sites”

$MeasType = DCID 12269 “Cardiac Ultrasound Interventricular Septum Measurements”

6

INCLUDE

DTID 5222 “Pediatric, Fetal and Congenital Cardiac Ultrasound Section”

1-n

U

$SectionSubject = DCID 12287 “Cardiac Ultrasound Ventricles Finding Sites”

$MeasType = DCID 12259 “Cardiac Ultrasound Ventricles Measurements”

8

INCLUDE

DTID 5222 “Pediatric, Fetal and Congenital Cardiac Ultrasound Section”

1-n

U

$SectionSubject = DCID 12288 “Cardiac Ultrasound Outflow Tracts Finding Sites”

$MeasType = DCID 12271 “Cardiac Ultrasound Outflow Tracts Measurements”

9

INCLUDE

DTID 5222 “Pediatric, Fetal and Congenital Cardiac Ultrasound Section”

1-n

U

$SectionSubject = DCID 12289 “Cardiac Ultrasound Semilunar Valves, Annulus and Sinuses Finding Sites”

$MeasType = DCID 12272 “Cardiac Ultrasound Semilunar Valves, Annulate and Sinuses Measurements”

10

INCLUDE

DTID 5222 “Pediatric, Fetal and Congenital Cardiac Ultrasound Section”

1-n

U

$SectionSubject = DCID 12290 “Cardiac Ultrasound Pulmonary Arteries Finding Sites”

$MeasType = DCID 12260 “Cardiac Ultrasound Pulmonary Artery”

11

INCLUDE

DTID 5222 “Pediatric, Fetal and Congenital Cardiac Ultrasound Section”

1-n

U

$SectionSubject = DCID 12291 “Cardiac Ultrasound Aorta Finding Sites”

$MeasType = DCID 12274 “Cardiac Ultrasound Aorta Measurements”

12

INCLUDE

DTID 5222 “Pediatric, Fetal and Congenital Cardiac Ultrasound Section”

1-n

U

$SectionSubject = DCID 12292 “Cardiac Ultrasound Coronary Arteries Finding Sites”

$MeasType = DCID 12275 “Cardiac Ultrasound Coronary Arteries Measurements”

13

INCLUDE

DTID 5222 “Pediatric, Fetal and Congenital Cardiac Ultrasound Section”

1-n

U

$SectionSubject = DCID 12293 “Cardiac Ultrasound Aortopulmonary Connections Finding Sites”

$MeasType = DCID 12276 “Cardiac Ultrasound Aorto Pulmonary Connections Measurements”

14

INCLUDE

DTID 5222 “Pediatric, Fetal and Congenital Cardiac Ultrasound Section”

1-n

U

$SectionSubject = DCID 12294 “Cardiac Ultrasound Pericardium and Pleura Finding Sites”

$MeasType = DCID 12277 “Cardiac Ultrasound Pericardium and Pleura Measurements”


DICOM PS3.16 2022b - Content Mapping Resource