1
|
|
|
CONTAINER
|
DCID 12245 “Cardiac Ultrasound Report Titles”
|
1
|
M
|
|
Root node
|
2
|
>
|
HAS CONCEPT MOD
|
INCLUDE
|
DTID 1204 “Language of Content Item and Descendants”
|
1
|
M
|
|
|
3
|
>
|
HAS OBS CONTEXT
|
INCLUDE
|
DTID 1001 “Observation Context”
|
1
|
M
|
|
|
4
|
>
|
CONTAINS
|
CONTAINER
|
EV (18785-6, LN, "Indications for Procedure")
|
1
|
U
|
|
|
5
|
>>
|
CONTAINS
|
CODE
|
EV (121071, DCM, "Finding")
|
1-n
|
U
|
|
DCID 12246 “Cardiac Ultrasound Indication for Study”
|
6
|
>>
|
CONTAINS
|
TEXT
|
EV (121071, DCM, "Finding")
|
1
|
U
|
|
|
7
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3802 “Cardiovascular Patient History”
|
1
|
U
|
|
|
8
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3602 “Cardiovascular Patient Characteristics”
|
1
|
U
|
|
|
9
|
>
|
CONTAINS
|
INCLUDE
|
DTID 5225 “Cardiac Ultrasound Fetal Characteristics”
|
1-n
|
U
|
|
No more than one inclusion per fetus
|
10
|
>
|
CONTAINS
|
INCLUDE
|
DTID 5226 “Cardiac Ultrasound Summary Section”
|
1
|
U
|
|
|
11
|
>
|
CONTAINS
|
INCLUDE
|
DTID 5227 “Cardiac Ultrasound Fetal Summary Section”
|
1-n
|
U
|
|
No more than one inclusion per fetus
|
12
|
>
|
CONTAINS
|
CONTAINER
|
EV (111028, DCM, "Image Library")
|
1
|
U
|
|
|
13
|
>>
|
CONTAINS
|
IMAGE
|
|
1-n
|
M
|
|
|
14
|
>
|
CONTAINS
|
INCLUDE
|
DTID 5221 “Cardiac Ultrasound Pediatric Echo Measurement Section”
|
1
|
U
|
|
|
15
|
>
|
CONTAINS
|
INCLUDE
|
DTID 5228 “Cardiac Ultrasound Fetal Measurement Section”
|
1-n
|
UC
|
For Fetal Report only.
|
No more than one inclusion per fetus
|