DICOM PS3.16 2021e - Content Mapping Resource

TID 4301 Genitourinary Patient History

This disease-specific template collects the details of a patient's genitourinary system history, such as those relevant in the context of prostate cancer screening, including abdominal surgeries, history of androgen deprivation therapy, digital rectal examination, and relevant labs.

Type:

Extensible

Order:

Significant

Root:

No

Table TID 4301. Genitourinary Patient History

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (130548, DCM, "Genitourinary History")

1

M

2

>

CONTAINS

TEXT

EV (11329-0, LN, "History")

1

U

3

>

CONTAINS

CONTAINER

DT (11450-4, LN, "Problem List")

1

U

4

>>

CONTAINS

TEXT

DCID 3769 “Concern Types”

1-n

U

5

>>

CONTAINS

INCLUDE

DTID 3829 “Problem Properties”

1-n

U

$Problem = DCID 6313 “History of Prostate Disease”

$Therapy = DCID 6323 “Prostate Cancer Therapy”

6

>

CONTAINS

CONTAINER

DT (29762-2, LN, "Social History")

1

U

7

>>

CONTAINS

TEXT

EV (160476009, SCT, "Social History")

1

U

8

>>

CONTAINS

CODE

EV (365981007, SCT, "Tobacco Smoking Behavior")

1

U

DCID 3724 “Smoking History”

9

>

CONTAINS

CONTAINER

DT (10167-5, LN, "Past Surgical History")

1

U

10

>>

CONTAINS

TEXT

EV (11329-0, LN, "History")

1-n

U

11

>>

CONTAINS

INCLUDE

DTID 3830 “Procedure Properties”

1-n

U

$ProcType = DCID 6319 “Abdominal Intervention Types”

$Procedure = DCID 6320 “Abdominal Interventions”

12

>

CONTAINS

CONTAINER

DT (30954-2, LN, "Relevant Diagnostic Tests and/or Laboratory Data")

1

U

13

>>

CONTAINS

TEXT

EV (11329-0, LN, "History")

1-n

U

14

>

CONTAINS

CONTAINER

DT (103693007, SCT, "Diagnostic procedure")

1-n

U

15

>>

CONTAINS

INCLUDE

DTID 1700 “Generic Blood Lab Measurements”

1-n

U

$Measurement = DCID 6352 “Prostate Cancer Diagnostic Blood Lab Measurements”

16

>>

CONTAINS

INCLUDE

DTID 3830 “Procedure Properties”

1-n

U

$ProcType = DT (103693007, SCT, "Diagnostic procedure")

$Procedure = DCID 6321 “Prostate Cancer Diagnostic Procedures”

ProcedureResult = DCID 242 “Normal-Abnormal”

17

>

CONTAINS

CONTAINER

DT (10160-0, LN, "History of Medication Use")

1

U

18

>>

CONTAINS

TEXT

DT (111516, DCM, "Medication Type")

1-n

U

19

>>>

HAS PROPERTIES

CODE

DT (33999-4, LN, "Status")

1

U

DCID 3773 “Use Status”

20

>>

CONTAINS

CODE

DT (111516, DCM, "Medication Type")

1-n

U

21

>>>

HAS PROPERTIES

NUM

DT (260911001, SCT, "Dosage")

1

U

22

>>>

HAS PROPERTIES

CODE

DT (33999-4, LN, "Status")

1

U

DCID 3773 “Use Status”

23

>

CONTAINS

CONTAINER

DT (10157-6, LN, "History of Family Member Diseases")

1

U

24

>>

CONTAINS

TEXT

EV (11329-0, LN, "History")

1-n

U

25

>>

CONTAINS

CODE

EV (416471007, SCT, "Family history of clinical finding")

1-n

U

DCID 6322 “Prostate Cancer Family History”

26

>>>

HAS PROPERTIES

CODE

EV (408732007, SCT, "Subject relationship")

1

M

DCID 7451 “Family Member”


DICOM PS3.16 2021e - Content Mapping Resource