1
|
|
|
CONTAINER
|
EV (111463, DCM, "Supplementary Data for Intervention")
|
1
|
M
|
|
|
2
|
>
|
CONTAINS
|
INCLUDE
|
DTID 4201 “Breast Imaging Procedure Reported”
|
1
|
M
|
|
|
3
|
>
|
CONTAINS
|
CODE
|
EV (57134006, SCT, "Instrument")
|
1
|
U
|
|
|
4
|
>>
|
HAS PROPERTIES
|
TEXT
|
EV (111465, DCM, "Needle Gauge")
|
1
|
UC
|
XOR row 5
|
|
5
|
>>
|
HAS PROPERTIES
|
CODE
|
EV (111465, DCM, "Needle Gauge")
|
1
|
UC
|
XOR row 4
|
|
6
|
>>
|
HAS PROPERTIES
|
NUM
|
EV (111467, DCM, "Needle Length")
|
1
|
U
|
|
UNITS = EV (cm, UCUM, "centimeter")
|
7
|
>
|
CONTAINS
|
NUM
|
EV (111436, DCM, "Number of passes")
|
1
|
U
|
|
UNITS = EV ({passes}, UCUM, "passes")
|
8
|
>
|
CONTAINS
|
NUM
|
EV (111437, DCM, "Number of specimens")
|
1
|
U
|
|
UNITS = EV ({specimens}, UCUM, "specimens")
|
9
|
>
|
CONTAINS
|
CODE
|
EV (111431, DCM, "Instrument Approach")
|
1-n
|
U
|
|
DCID 6065 “Instrument Approach”
|
10
|
>
|
CONTAINS
|
CODE
|
EV (111438, DCM, "Needle in target")
|
1
|
U
|
|
DCID 230 “Yes-No”
|
11
|
>
|
CONTAINS
|
NUM
|
EV (111439, DCM, "Number of needles around target")
|
1
|
U
|
|
UNITS = EV ({needles}, UCUM, "needles")
|
12
|
>
|
CONTAINS
|
CODE
|
EV (182833002, SCT, "Medication given")
|
1-n
|
U
|
|
|
13
|
>
|
CONTAINS
|
CODE
|
EV (111440, DCM, "Incision made")
|
1
|
U
|
|
DCID 230 “Yes-No”
|
14
|
>
|
CONTAINS
|
CODE
|
EV (111123, DCM, "Marker placement")
|
1
|
U
|
|
DCID 230 “Yes-No”
|
15
|
>
|
CONTAINS
|
CODE
|
EV (111442, DCM, "Confirmation of target")
|
1
|
U
|
|
DCID 6066 “Target Confirmation”
|
16
|
>
|
CONTAINS
|
CODE
|
EV (116224001, SCT, "Complication of procedure")
|
1-n
|
U
|
|
DCID 6062 “Interventional Procedure Complications”
|
17
|
>>
|
HAS PROPERTIES
|
CODE
|
EV (111466, DCM, "Severity of Complication")
|
1
|
U
|
|
DCID 251 “Severity of Complication”
|
18
|
>
|
CONTAINS
|
CONTAINER
|
EV (121027, DCM, "Specimen")
|
1-n
|
U
|
|
|
19
|
>>
|
HAS OBS CONTEXT
|
INCLUDE
|
DTID 1009 “Subject Context, Specimen”
|
1
|
U
|
|
|
20
|
>>
|
CONTAINS
|
CODE
|
EV (250431005, SCT, "Color of fluid")
|
1
|
U
|
|
DCID 6067 “Fluid Color”
|
21
|
>>
|
CONTAINS
|
CODE
|
EV (111456, DCM, "Action on fluid")
|
1
|
U
|
|
DT (111457, DCM, "Sent for analysis")
DT (111458, DCM, "Discarded")
|
22
|
>>
|
CONTAINS
|
CODE
|
EV (111455, DCM, "Occult blood test result")
|
1
|
U
|
|
DCID 250 “Positive-Negative”
|
23
|
>>
|
CONTAINS
|
INCLUDE
|
DTID 4207 “Breast Imaging Pathology Results”
|
1-n
|
U
|
|
|
24
|
>
|
CONTAINS
|
INCLUDE
|
DTID 350 “References to Supporting Evidence”
|
1
|
U
|
|
|