DICOM PS3.16 2022b - Content Mapping Resource

TID 4202 Breast Imaging Report Narrative

This Template contains the narrative text sub-tree of the content tree of a Breast Imaging Report. The narrative summary may be subdivided into sections with section headings.

See Figure Q.1-3 “Breast Imaging Report Narrative Content Tree” in PS3.17 .

Type:

Non-Extensible

Order:

Significant

Root:

No

Table TID 4202. Breast Imaging Report Narrative

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (111412, DCM, "Narrative Summary")

1

M

2

>

CONTAINS

CONTAINER

BCID 6052 “Breast Imaging Report Section Title”

1-n

M

3

>>

HAS OBS CONTEXT

INCLUDE

DTID 1002 “Observer Context”

1-n

U

4

>>

CONTAINS

TEXT

BCID 6053 “Breast Imaging Report Elements”

1

M

5

>>>

INFERRED FROM

INCLUDE

DTID 350 “References to Supporting Evidence”

1

U