DICOM PS3.16 2022b - Content Mapping Resource

TID 3909 Best Illustration of Findings

Specification of images, waveforms, spatial and temporal coordinates used to illustrate findings.

Type:

Extensible

Order:

Significant

Root:

No

Table TID 3909. Best Illustration of Findings

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINS

IMAGE

EV (121080, DCM, "Best illustration of finding")

1

U

2

CONTAINS

WAVEFORM

EV (121080, DCM, "Best illustration of finding")

1

U

3

CONTAINS

SCOORD

EV (121080, DCM, "Best illustration of finding")

1

U

4

>

SELECTED FROM

IMAGE

1

M

5

CONTAINS

TCOORD

EV (121080, DCM, "Best illustration of finding")

1

U

6

>

SELECTED FROM

SCOORD

1

MC

XOR Rows 8, 9

7

>>

SELECTED FROM

IMAGE

1

M

must be a multi-frame image

8

>

SELECTED FROM

WAVEFORM

1

MC

XOR Rows 6, 9

9

>

SELECTED FROM

IMAGE

1

MC

XOR Rows 6, 8

must be a multi-frame image


Content Item Descriptions

Rows 4, 7, 8, 9

No purpose of reference is specified.

DICOM PS3.16 2022b - Content Mapping Resource