1
|
|
CONTAINS
|
CONTAINER
|
EV (59776-5, LN, "Findings")
|
1
|
M
|
|
|
2
|
>
|
HAS CONCEPT MOD
|
CODE
|
EV (121058, DCM, "Procedure reported")
|
1
|
M
|
|
DT (265484009, SCT, "Left Ventriculography")
|
3
|
>
|
CONTAINS
|
CODE
|
EV (366188009, SCT, "Left Ventricular Function - Finding")
|
1
|
M
|
|
DCID 242 “Normal-Abnormal”
|
4
|
>
|
|
INCLUDE
|
DTID 300 “Measurement”
|
1
|
M
|
|
$Measurement = EV (10230-1, LN, "LV Ejection Fraction")
$Units = EV (%, UCUM, "%")
$Method = DCID 3748 “Angiographic EF Testing Method”
$Derivation = DCID 3745 “Calculation Method”
|
5
|
>
|
CONTAINS
|
CODE
|
EV (250929008, SCT, "Left Ventricular Cavity Size")
|
1
|
U
|
|
DCID 3705 “Chamber Size”
|
6
|
>
|
CONTAINS
|
CODE
|
EV (250909007, SCT, "Left Ventricular Contractility")
|
1
|
U
|
|
DCID 3706 “Overall Contractility”
|
7
|
>
|
CONTAINS
|
CODE
|
EV (121071, DCM, "Finding")
|
1
|
U
|
|
EV (30288003, SCT, "Ventricular Septal Defect")
|
8
|
>>
|
HAS PROPERTIES
|
CODE
|
EV (116676008, SCT, "Associated Morphology")
|
1
|
U
|
|
DCID 3707 “VSD Description”
|
9
|
>
|
CONTAINS
|
INCLUDE
|
DTID 3816 “Ventricular Assessment”
|
1
|
U
|
|
|
10
|
>
|
CONTAINS
|
CONTAINER
|
EV (59776-5, LN, "Findings")
|
1
|
U
|
|
|
11
|
>>
|
HAS CONCEPT MOD
|
CODE
|
EV (363698007, SCT, "Finding Site")
|
1
|
M
|
|
DT (272657006, SCT, "Myocardial Wall")
|
12
|
>>
|
CONTAINS
|
CODE
|
EV (18179-2, LN, "Wall Segment")
|
1-n
|
M
|
|
BCID 3717 “Left Ventricle Myocardial Wall 17 Segments”
|
13
|
>>>
|
HAS PROPERTIES
|
CODE
|
EV (60797005, SCT, "Cardiac Wall Motion")
|
1
|
M
|
|
DCID 3703 “Wall Motion”
|
14
|
>>>
|
HAS PROPERTIES
|
CODE
|
EV (116676008, SCT, "Associated Morphology")
|
1
|
U
|
|
DCID 3704 “Myocardium Wall Morphology Findings”
|
15
|
>>>
|
HAS PROPERTIES
|
NUM
|
DT (246262008, SCT, "Score")
|
1
|
U
|
|
|
16
|
>
|
CONTAINS
|
CONTAINER
|
EV (59776-5, LN, "Findings")
|
1
|
U
|
|
|
17
|
>>
|
HAS CONCEPT MOD
|
CODE
|
EV (363698007, SCT, "Finding Site")
|
1
|
M
|
|
DT (364091008, SCT, "Aortic Root")
|
18
|
>>
|
CONTAINS
|
CODE
|
EV (121071, DCM, "Finding")
|
1-n
|
M
|
|
DCID 3709 “Aortic Root Description”
|