DICOM PS3.16 2024c - Content Mapping Resource

TID 3756 Waveform Library Entry Descriptors

This Template contains selected attributes for a waveform or a group of waveforms. The descriptive information may be copied from the waveforms or derived.

Type:

Extensible

Order:

Non-Significant

Root:

No

Table TID 3756. Waveform Library Entry Descriptors

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

HAS ACQ CONTEXT

CODE

EV (121139, DCM, "Modality")

1

U

DCID 29 “Acquisition Modality”

2

HAS ACQ CONTEXT

DATE

EV (111060, DCM, "Study Date")

1

U

3

HAS ACQ CONTEXT

TIME

EV (111061, DCM, "Study Time")

1

U

4

HAS ACQ CONTEXT

DATE

EV (111018, DCM, "Content Date")

1

U

5

HAS ACQ CONTEXT

TIME

EV (111019, DCM, "Content Time")

1

U

6

HAS ACQ CONTEXT

DATETIME

EV (130884, DCM, "Acquisition DateTime")

1

U

7

HAS ACQ CONTEXT

UIDREF

EV (130885, DCM, "Synchronization Frame of Reference UID")

1

U

8

CONTAINS

INCLUDE

DTID 3757 “Waveform Library Entry Multiplex Group Descriptors”

1-n

U