DICOM PS3.16 2022b - Content Mapping Resource

CID 7140 Brain Structures for Volumetric Measurements

Resources:

HTML | FHIR JSON | FHIR XML | IHE SVS XML

Type:

Extensible

Version:

20220402

UID:

1.2.840.10008.6.1.967

Table CID 7140. Brain Structures for Volumetric Measurements

Coding Scheme Designator

Code Value

Code Meaning

SNOMED-RT ID

UMLS Concept Unique ID

SCT

4958002

Amygdala

T-A3230

C0002708

SCT

119238007

Brain Stem

T-D0558

C1268144

SCT

11000004

Caudate Nucleus

T-A3200

C0007461

SCT

25991003

Cerebellar Cortex

T-A6040

C0007759

SCT

33060004

Cerebellar White Matter

T-A6080

C0152381

SCT

113305005

Cerebellum

T-A6000

C0007765

SCT

40146001

Cerebral Gray Matter

T-A2020

C0007776

SCT

68523003

Cerebral White Matter

T-A2030

C0152295

SCT

1101003

Cranial Cavity

T-D1400

C0230041

SCT

33930006

Cranial Subarachnoid Space

T-A1502

C0228145

SCT

74968005

Cavum of septum pellucidum

T-A1630

C0228158

SCT

35918002

Fourth Ventricle

T-A1820

C0149556

SCT

14738005

Globus Pallidus

T-A3500

C0017651

SCT

5366008

Hippocampus

T-A2570

C0019564

SCT

263972004

Cerebellar Subarachnoid Space

T-A1509

C0446676

SCT

53118009

Inferior Horn of Lateral Ventricle

T-A1720

C0152283

SCT

66720007

Lateral Ventricle

T-A1650

C0152279

SCT

427667007

Nucleus Accumbens

T-A0149

C0028633

SCT

128319008

Intracranial structure

T-A0190

C1267697

SCT

89278009

Putamen

T-A3400

C0034169

SCT

119406000

Thalamus

T-D0593

C0458271

SCT

49841001

Third ventricle

T-A1740

C0149555

DCM

110700

Ventral Diencephalon

DCM

110701

White Matter T1 Hypointensity

DCM

110702

White Matter T2 Hyperintensity


Note

  1. (1101003, SCT, "Cranial Cavity") may be used to describe the volume of the entire intra-cranial space (intra-cranial volume or ICV) though the coded concept used is "structure of" rather than "entire" to be consistent with normal DICOM practice.

  2. (25991003, SCT, "Cerebellar Cortex") is the gray matter of the cerebellum (as distinct from (33060004, SCT, "Cerebellar white matter")).

  3. (33930006, SCT, "Cranial Subarachnoid Space") may be used to describe the volume of the exterior CSF (surrounding the brain, excluding the ventricles).

  4. (263972004, SCT, "Cerebellar Subarachnoid Space") may be used to describe the volume of the inferior intracranial CSF space (infra-tentorial).

DICOM PS3.16 2022b - Content Mapping Resource