DICOM PS3.16 2026b - Content Mapping Resource

CID 6117 Vascular Anatomy

Resources:

HTML | FHIR JSON | FHIR XML | IHE SVS XML

Keyword:

VascularAnatomy

FHIR Keyword:

dicom-cid-6117-VascularAnatomy

Type:

Extensible

Version:

20200309

UID:

1.2.840.10008.6.1.437

Table CID 6117. Vascular Anatomy

Coding Scheme Designator

Code Value

Code Meaning

SNOMED-RT ID

UMLS Concept Unique ID

Include CID 3015 “Coronary Artery”

SCT

57034009

Aortic arch

T-42300

C0003489

SCT

88593004

Aortic isthmus

T-42310

C0226019

DCM

112102

Aortic knob

DCM

112103

Arch of the Azygos vein

SCT

54247002

Ascending aorta

T-42100

C0003956

SCT

67937003

Axillary Artery

T-47100

C0004455

SCT

68705008

Axillary vein

T-49110

C0004456

SCT

72107004

Azygos vein

T-48340

C0004526

SCT

17137000

Brachial artery

T-47160

C0006087

SCT

12691009

Brachiocephalic trunk

T-46010

C0006094

SCT

8887007

Brachiocephalic vein

T-48620

C0006095

SCT

64468002

Bronchial artery

T-46310

C0006257

SCT

32062004

Common carotid artery

T-45100

C0162859

SCT

3159004

Costocervical trunk

T-46180

C0226273

SCT

281130003

Descending aorta

T-D0765

C0011666

SCT

91732003

Dorsal scapular artery

T-461A0

C0500583

SCT

206034008

Esophageal artery

T-4630D

C0226294

SCT

71585003

External jugular vein

T-48160

C0226543

SCT

29660000

Inferior phrenic artery

T-46940

C0226406

SCT

64131007

Inferior vena cava

T-48710

C0042458

SCT

281134007

Intercostal artery

T-D305A

C0459917

SCT

12123001

Internal jugular vein

T-48170

C0226550

SCT

69327007

Internal thoracic artery

T-46200

C0226276

SCT

3924000

Pericardiophrenic Artery

T-46210

C0226287

SCT

81040000

Pulmonary artery

T-44000

C0034052

SCT

45341000

Pulmonary trunk

T-44100

C0034052

SCT

122972007

Pulmonary vein

T-48581

C0034090

SCT

36765005

Subclavian artery

T-46100

C0038530

SCT

9454009

Subclavian vein

T-48330

C0038532

SCT

38991005

Superior phrenic artery

T-46350

C0226295

SCT

48345005

Superior vena cava

T-48610

C0042459

SCT

6538005

Thyrocervical trunk

T-46130

C0226263

SCT

85234005

Vertebral artery

T-45700

C0042559


Note

In a prior version of this Context Group the code (T-48500, SRT, "Entire pulmonary vein") rather than (122972007, SCT, "Pulmonary Vein") was defined for the concept Pulmonary Vein; this was inconsistent with the DICOM approach of selecting the "structure of" rather than "entire" concept. Although there is minimal possibility of misinterpretation with SOP Instances that may include the deprecated use, receiving applications should be aware of this change; see Annex J.

DICOM PS3.16 2026b - Content Mapping Resource