DICOM PS3.16 2026c - Content Mapping Resource

TID 9001 Gynecological History

This general Template collects the details of a patient's reproductive system history, such as number of births, and gynecological surgery history.

Type:

Extensible

Order:

Significant

Root:

No

Table TID 9001. Gynecological History

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (267011001, SCT, "Gynecological History")

1

M

2

>

HAS OBS CONTEXT

CODE

EV (111534, DCM, "Role of person reporting")

1

U

DCID 7450 “Person Role”

3

>

CONTAINS

DATE

EV (8665-2, LN, "Last menstrual period")

1

U

4

>

CONTAINS

NUM

EV (111518, DCM, "Age when first menstrual period occurred")

1

U

UNITS = EV (a, UCUM, "Year")

5

>

CONTAINS

NUM

EV (111519, DCM, "Age at First Full Term Pregnancy")

1

U

UNITS = EV (a, UCUM, "Year")

6

>

CONTAINS

NUM

EV (11977-6, LN, "Para")

1

U

UNITS = EV (1, UCUM, "no units")

7

>

CONTAINS

NUM

EV (11639-2, LN, "Term")

1

U

UNITS = EV (1, UCUM, "no units")

8

>

CONTAINS

NUM

EV (11637-6, LN, "Preterm")

1

U

UNITS = EV (1, UCUM, "no units")

9

>

CONTAINS

NUM

EV (11636-8, LN, "Live Births")

1

U

UNITS = EV (1, UCUM, "no units")

10

>

CONTAINS

NUM

EV (111593, DCM, "LBW or IUGR")

1

U

UNITS = EV (1, UCUM, "no units")

11

>

CONTAINS

NUM

EV (11996-6, LN, "Gravida")

1

U

UNITS = EV (1, UCUM, "no units")

12

>

CONTAINS

NUM

EV (11612-9, LN, "Abortus")

1

U

UNITS = EV (1, UCUM, "no units")

13

>

CONTAINS

NUM

EV (33065-4, LN, "Ectopic Pregnancies")

1

U

UNITS = EV (1, UCUM, "no units")

14

>

CONTAINS

NUM

EV (111520, DCM, "Age at Menopause")

1

U

UNITS = EV (a, UCUM, "Year")

15

>

CONTAINS

NUM

EV (111521, DCM, "Age when hysterectomy performed")

1

U

UNITS = EV (a, UCUM, "Year")

16

>>

HAS CONCEPT MOD

CODE

EV (255590007, SCT, "Extent")

1

U

EV (255594003, SCT, "Complete")

EV (255609007, SCT, "Partial")

17

>

CONTAINS

NUM

EV (111522, DCM, "Age when left ovary removed")

1

U

UNITS = EV (a, UCUM, "Year")

18

>

CONTAINS

NUM

EV (111523, DCM, "Age when right ovary removed")

1

U

UNITS = EV (a, UCUM, "Year")

19

>

CONTAINS

CODE

EV (111543, DCM, "Breast feeding history")

1

U

DCID 230 “Yes-No”

20

>>

HAS PROPERTIES

NUM

EV (111544, DCM, "Average breast feeding period")

1

U

UNITS = EV (wk, UCUM, "Week")

21

>

CONTAINS

CODE

EV (364320009, SCT, "Pregnancy observable")

1

U

DCID 6096 “Pregnancy Status”

22

>

CONTAINS

CODE

EV (111391, DCM, "Menstrual Cycle Phase")

1

U

DCID 6163 “Menstrual Cycle Phase”


DICOM PS3.16 2026c - Content Mapping Resource