DICOM PS3.16 2026d - Content Mapping Resource

TID 8110 Biosafety Conditions

This template encodes a description of the biosafety conditions applicable to research small animals.

Type:

Extensible

Order:

Non-Significant

Root:

No

Table TID 8110. Biosafety Conditions

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (127010, DCM, "Biosafety conditions")

1

M

2

>

CONTAINS

CODE

EV (409599009, SCT, "Biosafety level")

1

U

DCID 601 “Biosafety Level”

3

>

CONTAINS

CODE

EV (127011, DCM, "Reason for biosafety controls")

1

U

DCID 602 “Biosafety Control Reason”

4

>

CONTAINS

TEXT

EV (121106, DCM,"Comment")

1

U


Content Item Descriptions

Row 4

A brief description of any pertinent or unusual biosafety requirements.