DICOM PS3.16 2026d - Content Mapping Resource

TID 5228 Cardiac Ultrasound Fetal Measurement Section

Type:

Extensible

Order:

Significant

Root:

No

Table TID 5228. Cardiac Ultrasound Fetal Measurement Section

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (125016, DCM, "Fetal Measurements")

1

M

2

>

HAS OBS CONTEXT

INCLUDE

DTID 1008 “Subject Context, Fetus”

1

MC

IF this Template is invoked more than once to describe more than one fetus.

3

>

CONTAINS

INCLUDE

DTID 300 “Measurement”

1-n

U

$Measurement = DCID 12279 “Cardiac Ultrasound Fetal General Measurement”

4

>

CONTAINS

INCLUDE

DTID 5222 “Pediatric, Fetal and Congenital Cardiac Ultrasound Section”

1-n

U

$SectionSubject = EV (4432005, SCT, "Ductus arteriosus")

$MeasType = DCID 12218 “Echocardiography Congenital Anomaly Measurement”

4a

>

CONTAINS

INCLUDE

DTID 5222 “Pediatric, Fetal and Congenital Cardiac Ultrasound Section”

1-n

U

$SectionSubject = EV (131021, DCM, "Ductus Arteriosus Arch")

$MeasType = DCID 12218 “Echocardiography Congenital Anomaly Measurement”

4b

>

CONTAINS

INCLUDE

DTID 5222 “Pediatric, Fetal and Congenital Cardiac Ultrasound Section”

1-n

U

$SectionSubject = EV (32672002, SCT, "Descending Thoracic Aorta")

$MeasType = DCID 12218 “Echocardiography Congenital Anomaly Measurement”

5

>

CONTAINS

INCLUDE

DTID 5222 “Pediatric, Fetal and Congenital Cardiac Ultrasound Section”

1-n

U

$SectionSubject = EV (367624001, SCT, "Ductus venosus")

$MeasType = DCID 12218 “Echocardiography Congenital Anomaly Measurement”

6

>

CONTAINS

INCLUDE

DTID 5222 “Pediatric, Fetal and Congenital Cardiac Ultrasound Section”

1-n

U

$SectionSubject = EV (50536004, SCT, "Umbilical artery")

$MeasType = DCID 12218 “Echocardiography Congenital Anomaly Measurement”

7

>

CONTAINS

INCLUDE

DTID 5222 “Pediatric, Fetal and Congenital Cardiac Ultrasound Section”

1-n

U

$SectionSubject = EV (367567000, SCT, "Umbilical vein")

$MeasType = DCID 12218 “Echocardiography Congenital Anomaly Measurement”

8

>

CONTAINS

INCLUDE

DTID 5222 “Pediatric, Fetal and Congenital Cardiac Ultrasound Section”

1-n

U

$SectionSubject = EV (17232002, SCT, "Middle cerebral artery")

$MeasType = DCID 12218 “Echocardiography Congenital Anomaly Measurement”

9

>

CONTAINS

INCLUDE

DTID 5221 “Cardiac Ultrasound Pediatric Echo Measurement Section”

1

U

10

>

CONTAINS

INCLUDE

DTID 5229 “Cardiac Ultrasound Post-Coordinated Measurement Section”

1-n

U

$Measurement = BCID 12314 “Common Fetal Echocardiography Measurements”


Content Item Descriptions

Row 4b

This inclusion of TID 5222 facilitates reporting the PLAS Index (Post-Left Arterial Space) which is based in part on measurements of the descending thoracic aorta.

Row 9

This inclusion of TID 5221 facilitates the use of any pediatric echo measurement(s) appropriate for fetal assessment. Some measurements might only be appropriate for late stage fetal assessment. None of the TID 5221 content is inherently pediatric-specific.

Row 10

This row permits inclusion of section containers with one or more fully post-coordinated echo measurements.