DICOM PS3.16 2026a - Content Mapping Resource

TID 5222 Pediatric, Fetal and Congenital Cardiac Ultrasound Section

This is a generic section heading Template for any of the anatomical headings. Measurements within a section heading appear as groups (by image mode or acquisition protocol).

Table TID 5222. Parameters

Parameter Name

Parameter Usage

$SectionSubject

The subject modifier of the section heading container

$MeasType

The concept name of the measurement


Type:

Extensible

Order:

Significant

Root:

No

Table TID 5222. Pediatric, Fetal and Congenital Cardiac Ultrasound Section

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (59776-5, LN, "Findings")

1

M

2

>

HAS CONCEPT MOD

CODE

EV (363698007, SCT, "Finding Site")

1

M

$SectionSubject

3

>>

HAS CONCEPT MOD

CODE

EV (307279007, SCT, "Prosthetic replacement of heart valve")

1

U

DCID 230 “Yes-No”

4

>

CONTAINS

CONTAINER

DT (125007, DCM, "Measurement Group")

1-n

M

5

>>

HAS CONCEPT MOD

CODE

EV (399264008, SCT, "Image Mode")

1

U

BCID 12224 “Ultrasound Image Mode”

6

>>

HAS CONCEPT MOD

TEXT

DT (125203, DCM, "Acquisition Protocol")

1

U

7

>>

CONTAINS

INCLUDE

DTID 5223 “Pediatric, Fetal and Congenital Cardiac Ultrasound Measurement”

1-n

M

$Measurement = $MeasType

$Method = CID 12227 “Echocardiography Measurement Method”


DICOM PS3.16 2026a - Content Mapping Resource