DICOM PS3.16 2026d - Content Mapping Resource

TID 3926 Myocardial Perfusion Analysis

Myocardial perfusion analysis results.

Perfusion measurements may be performed either for one or more ventricular segments (Row 4) or for substructures inside ventricular segments (Row 14)

Type:

Extensible

Order:

Significant

Root:

No

Table TID 3926. Myocardial Perfusion Analysis

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINS

CONTAINER

EV (59776-5, LN, "Findings")

1

M

2

>

HAS CONCEPT MOD

CODE

EV (111004, DCM, "Analysis Performed")

1

M

EV (122602, DCM, "Myocardial Perfusion Analysis")

3

>

CONTAINS

CONTAINER

EV (59776-5, LN, "Findings")

1-n

M

4

>>

HAS CONCEPT MOD

CODE

EV (363698007, SCT, "Finding Site")

1-n

MC

XOR Row 6

DCID 3717 “Left Ventricle Myocardial Wall 17 Segment Model”

5

>>>

HAS CONCEPT MOD

CODE

EV (106233006, SCT, "Topographical Modifier")

1

U

DCID 3843 “Myocardial Subsegment”

6

>>

HAS CONCEPT MOD

TEXT

EV (363698007, SCT, "Finding Site")

1

MC

XOR Row 4

7

>>

HAS ACQ CONTEXT

CODE

EV (109054, DCM, "Patient State")

1

U

DCID 3101 “Cardiac Procedural State Value”

8

>>

HAS ACQ CONTEXT

INCLUDE

DTID 3106 “Drugs/Contrast Administered”

1-n

U

9

>>

CONTAINS

TEXT

EV (122627, DCM, "Curve Fit Method")

1

U

10

>>

CONTAINS

INCLUDE

DTID 3909 “Best Illustration of Findings”

1-n

U

11

>>

CONTAINS

TEXT

EV (122628, DCM, "Baseline Result Correction")

1

U

12

>>

CONTAINS

INCLUDE

DTID 300 “Measurement”

1-n

U

$Measurement = DCID 3836 “Time-based Perfusion Measurement”

$Units = EV (s, UCUM, "s")

13

>>

CONTAINS

NUM

EV (122640, DCM, "Image Interval")

1

U

UNITS = EV (ms, UCUM, "ms")

14

>>

CONTAINS

NUM

EV (122635, DCM, "MR Perfusion Peak")

1

U

UNITS = DT (1, UCUM, "No units")

15

>>

CONTAINS

NUM

EV (122636, DCM, "MR Perfusion Slope")

1

U

UNITS = DT (1, UCUM, "No units")

16

>>

CONTAINS

NUM

EV (122637, DCM, "MR Perfusion Time Integral")

1

U

UNITS = DT (1, UCUM, "No units")

17

>>

CONTAINS

CONTAINER

EV (125007, DCM, "Measurement Group")

1-n

U

18

>>>

CONTAINS

INCLUDE

DTID 300 “Measurement”

1-n

U

$Measurement = DCID 3836 “Time-based Perfusion Measurement”

$Units = EV (s, UCUM, "s")

19

>>>

CONTAINS

NUM

EV (122635, DCM, "MR Perfusion Peak")

1

U

UNITS = DT (1, UCUM, "No units")

20

>>>

CONTAINS

NUM

EV (122636, DCM, "MR Perfusion Slope")

1

U

UNITS = DT (1, UCUM, "No units")

21

>>>

CONTAINS

NUM

EV (122637, DCM, "MR Perfusion Time Integral")

1

U

UNITS = DT (1, UCUM, "No units")

22

>>

CONTAINS

CODE

EV (122664, DCM, "Late Contrast Enhancement")

1

U

DCID 230 “Yes-No”

23

>>>

HAS PROPERTIES

NUM

EV (122665, DCM, "Time interval since injection of contrast media")

1

M

UNITS = DT (s, UCUM, "s")

24

>>>

HAS PROPERTIES

NUM

EV (122668, DCM, "Time interval since detection of contrast bolus")

1

U

UNITS = DT (s, UCUM, "s")


Content Item Descriptions

Row 12

Image Interval is appropriate only for equally time-spaced images

Rows 23, 24

Previously, the relationship was specified as HAS ACQ CONTEXT rather than HAS PROPERTIES, which is not permitted by the Enhanced or Comprehensive SR IOD Relationship Constraints. The usage of HAS ACQ CONTEXT for these Rows has been retired. See PS3.16-2025c.