DICOM PS3.16 2025a - Content Mapping Resource

TID 3922 Absolute Values of Ventricular Measurements

Ventricular measurement results related to the absolute volume of a ventricle.

Type:

Extensible

Order:

Significant

Root:

No

Table TID 3922. Absolute Values of Ventricular Measurements

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINS

CONTAINER

EV (122608, DCM, "Absolute Values Of Ventricular Measurements")

1

M

2

>

CONTAINS

INCLUDE

DTID 300 “Measurement”

1-n

U

$Measurement = DCID 3833 “Cardiac Ejection Fraction”

$ModType = DT (122670, DCM, "Papillary Muscle Included/Excluded")

$ModValue = DCID 3821 “Papillary Muscle Included/Excluded”

$Method = DCID 3807 “Volume Measurement Method”

$Units = DT (%, UCUM, "%")

3

>

CONTAINS

INCLUDE

DTID 300 “Measurement”

1-n

U

$Measurement = DCID 3835 “Cardiac Volume Measurement”

$ModType = DT (122670, DCM, "Papillary Muscle Included/Excluded")

$ModValue = DCID 3821 “Papillary Muscle Included/Excluded”

$Units = DT (ml, UCUM, "ml")

4

>

CONTAINS

INCLUDE

DTID 300 “Measurement”

1

U

$Measurement = EV (82799009, SCT, "Cardiac Output")

$ModType = DT (122670, DCM, "Papillary Muscle Included/Excluded")

$ModValue = DCID 3821 “Papillary Muscle Included/Excluded”

$Units = DT (l/min, UCUM, "l/min")

5

>

CONTAINS

INCLUDE

DTID 300 “Measurement”

1-n

U

$Measurement = EV (122447, DCM, "Wall Mass")

$ModType = DT (122670, DCM, "Papillary Muscle Included/Excluded")

$ModValue = DCID 3821 “Papillary Muscle Included/Excluded”

$Units = DT (g, UCUM, "g")

6

>>

HAS CONCEPT MOD

CODE

EV (272518008, SCT, "Cardiac Cycle Point")

1

U

DCID 12233 “Cardiac Phase”

7

>

CONTAINS

INCLUDE

DTID 300 “Measurement”

1

U

$Measurement = EV (122616, DCM, "Peak Ejection Rate")

$Units = DT (ml/s, UCUM, "ml/s")

8

>

CONTAINS

NUM

EV (122617, DCM, "Peak Ejection Time")

1

U

UNITS = EV (s, UCUM, "s")

9

>>

HAS CONCEPT MOD

CODE

EV (122611, DCM, "Reference Point")

1

M

EV (416190007, SCT, "End-Diastolic")

10

>

CONTAINS

INCLUDE

DTID 300 “Measurement”

1

U

$Measurement = EV (122618, DCM, "Peak Filling Rate")

$Units = DT (ml/s, UCUM, "ml/s")

11

>

CONTAINS

NUM

EV (122619, DCM, "Peak Filling Time")

1

U

UNITS = DT (s, UCUM, "s")

12

>>

HAS CONCEPT MOD

CODE

EV (122611, DCM, "Reference Point")

1

M

DT (109070, DCM, "End-Systolic")


DICOM PS3.16 2025a - Content Mapping Resource