DICOM PS3.16 2026c - Content Mapping Resource

TID 3550 Pressure Waveform Measurements

The Pressure Waveform Measurements Template is invoked by the various hemodynamic measurement Templates for recording general measurements made in conjunction with the specific required measurements for that anatomic location.

Type:

Extensible

Order:

Significant

Root:

No

Table TID 3550. Pressure Waveform Measurements

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINS

INCLUDE

DTID 300 “Measurement”

1-n

U

$Measurement = DCID 3611 “Pressure Measurement”

$Units = DCID 3500 “Pressure Unit”

2

CONTAINS

INCLUDE

DTID 300 “Measurement”

1-n

U

$Measurement = DCID 3612 “Blood Velocity Measurement”

$Units = EV (mm/s, UCUM, "mm/s")

3

CONTAINS

INCLUDE

DTID 300 “Measurement”

1-n

U

$Measurement = DCID 3613 “Hemodynamic Time Measurement”

$Units = DT (ms, UCUM, "ms")

4

CONTAINS

INCLUDE

DTID 300 “Measurement”

1

U

$Measurement = EV (82799009, SCT, "Cardiac Output")

$Units = EV (l/min, UCUM, "l/min")

5

CONTAINS

INCLUDE

DTID 300 “Measurement”

1

U

$Measurement = EV (90096001, SCT, "Stroke Volume")

$Units = DT (ml, UCUM, "ml")

6

CONTAINS

INCLUDE

DTID 300 “Measurement”

1

U

$Measurement = EV (10230-1, LN, "LV Ejection Fraction")

$Units = EV (%, UCUM, "%")

7

CONTAINS

INCLUDE

DTID 300 “Measurement”

1

U

$Measurement = EV (8867-4, LN, "Heart rate")

$Units = DT ({H.B.}/min, UCUM, "BPM")

8

CONTAINS

INCLUDE

DTID 300 “Measurement”

1

U

$Measurement = EV (86290005, SCT, "Respiration rate")

$Units = DT (/min, UCUM, "breaths/min")

9

CONTAINS

INCLUDE

DTID 300 “Measurement”

1

U

$Measurement = EV (109025, DCM, "Max dp/dt")

$Units = DT (mm[Hg]/s, UCUM, "mmHg/s")

10

CONTAINS

INCLUDE

DTID 300 “Measurement”

1

U

$Measurement = EV (109026, DCM, "Max neg dp/dt")

$Units = DT (mm[Hg]/s, UCUM, "mmHg/s")

11

CONTAINS

INCLUDE

DTID 300 “Measurement”

1

U

$Measurement = EV (122190, DCM, "Max dp/dt/P")

$Units = DT (/s, UCUM, "/s")

12

CONTAINS

INCLUDE

DTID 300 “Measurement”

1

U

$Measurement = EV (122192, DCM, "Indicator appearance time")

$Units = DT (s, UCUM, "s")

13

CONTAINS

INCLUDE

DTID 300 “Measurement”

1

U

$Measurement = EV (122193, DCM, "Maximum pressure acceleration")

$Units = DT (mm[Hg]/s2, UCUM, "mmHg/s/s")

14

CONTAINS

INCLUDE

DTID 300 “Measurement”

1-n

U

$Measurement = DCID 3617 “Valve Flow”

$Units = DT (ml/min, UCUM, "ml/min")


DICOM PS3.16 2026c - Content Mapping Resource