DICOM PS3.16 2026c - Content Mapping Resource

TID 3311 Stress Test Summary

Type:

Extensible

Order:

Significant

Root:

No

Table TID 3311. Stress Test Summary

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (55112-7, LN, "Summary")

1

M

2

>

CONTAINS

TEXT

EV (55112-7, LN, "Summary")

1

U

3

>

CONTAINS

INCLUDE

DTID 3312 “Physiological Summary”

1

U

4

>

CONTAINS

INCLUDE

DTID 3313 “Stress ECG Summary”

1

U

5

>

CONTAINS

INCLUDE

DTID 3317 “Stress Imaging Summary”

1

U

6

>

CONTAINS

CODE

EV (121071, DCM, "Finding")

1

U

EV (300995000, SCT, "Exercise-induced angina")

7

>>

INCLUDE

DTID 1350 “Negation Modifier, Presence of Finding”

1

M

8

>

CONTAINS

CODE

EV (121071, DCM, "Finding")

1-n

U

DCID 3220 “Stress Symptom”

9

>

CONTAINS

TEXT

EV (121071, DCM, "Finding")

1

U

10

>

CONTAINS

CODE

DT (246101005, SCT, "Reason for stopping test")

1

U

DCID 3221 “Stress Test Termination Reason”

11

>

CONTAINS

NUM

DT (122715, DCM, "Pharmacological Stress Agent Dose")

1

U

DT (mg/kg, UCUM, "mg/kg")


Content Item Descriptions

Rows 6, 7

These rows allow an explicit finding of presence or absence of exercise-induced angina through the TID 1350 “Negation Modifier, Presence of Finding” Concept Modifier "Presence of property"

DICOM PS3.16 2026c - Content Mapping Resource