DICOM PS3.16 2026d - Content Mapping Resource

TID 2121 Visual Field Key Measurements

Type:

Extensible

Order:

Non-Significant

Root:

Yes

Table TID 2121. Visual Field Key Measurements

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (131240, DCM, "Visual Field Key Measurements")

1

M

2

>

HAS CONCEPT MOD

INCLUDE

DTID 1204 “Language of Content Item and Descendants”

1

U

3

>

HAS OBS CONTEXT

INCLUDE

DTID 1002 “Observer Context”

1-n

U

4

>

HAS OBS CONTEXT

INCLUDE

DTID 4019 “Algorithm Identification”

1

U

5

>

CONTAINS

CONTAINER

EV (125007, DCM, "Measurement Group")

1-n

M

6

>>

HAS CONCEPT MOD

CODE

EV (363698007, SCT, "Finding Site")

1

M

EV (81745001, SCT, "Eye")

7

>>>

HAS CONCEPT MOD

CODE

EV (272741003, SCT, "Laterality")

1

M

DCID 247 “Laterality Left-Right Only”

8

>>

HAS CONCEPT MOD

CODE

EV (370129005, SCT, "Measurement Method")

1

M

DCID 4250 “Visual Field Static Perimetry Test Pattern”

9

>>

HAS ACQ CONTEXT

CODE

EV (246501002, SCT, "Technique")

1

M

DCID 4251 “Visual Field Static Perimetry Test Strategy”

10

>>

HAS OBS CONTEXT

INCLUDE

DTID 4108 “Tracking Identifier”

1

U

11

>>

CONTAINS

INCLUDE

DTID 300 “Measurement”

1

M

$Measurement = EV (131248, DCM, "Visual Field Global Deviation from Normal")

$Units = EV (dB, UCUM, "dB")

12

>>

CONTAINS

INCLUDE

DTID 300 “Measurement”

1

M

$Measurement = EV (131249, DCM, "Visual Field Localized Deviation From Normal")

$Units = EV (dB, UCUM, "dB")

13

>>

CONTAINS

INCLUDE

DTID 300 “Measurement”

1

U

$Measurement = BCID 4280 “Visual Field Measurements”

14

>>

CONTAINS

INCLUDE

DTID 314 “Ratio”

1

MC

IF Row 15 not present

$Measurement = EV (131250, DCM, "Fixation false positive ratio")

$NumUnits = EV ({false positives}, UCUM, "false positives")

$DenomUnits = EV ({trials}, UCUM, "trials")

15

>>

CONTAINS

INCLUDE

DTID 300 “Measurement”

1

MC

IF Row 14 not present

$Measurement = EV (131251, DCM, "Fixation false positive percent")

$Units = EV (%, UCUM, "%")

16

>>

CONTAINS

INCLUDE

DTID 314 “Ratio”

1

MC

IF Row 17 not present

$Measurement = EV (131252, DCM, "Fixation false negative ratio")

$NumUnits = EV ({false negatives}, UCUM, "false negatives")

$DenomUnits = EV ({trials}, UCUM, "trials")

17

>>

CONTAINS

INCLUDE

DTID 300 “Measurement”

1

MC

IF Row 16 not present

$Measurement = EV (131253, DCM, "Fixation false negative percent")

$Units = EV (%, UCUM, "%")

18

>>

CONTAINS

INCLUDE

DTID 314 “Ratio”

1

M

$Measurement = EV (131254, DCM, "Fixation losses ratio")

$NumUnits = EV ({fixation losses}, UCUM, "fixation losses")

$DenomUnits = EV ({trials}, UCUM, "trials")

19

>>

CONTAINS

CODE

EV (111855, DCM, "Glaucoma Hemifield Test Analysis")

1

U

DCID 4254 “Visual Field Static Perimetry Test Analysis Result”

20

>>

CONTAINS

COMPOSITE

EV (121112, DCM, "Source of Measurement")

1

U

21

>>

CONTAINS

IMAGE

EV (130401, DCM, "Visual explanation")

1

U

22

>>

CONTAINS

COMPOSITE

EV (130401, DCM, "Visual explanation")

1

U

23

>>

CONTAINS

TEXT

EV (121106, DCM, "Comment")

1

U


Content Item Descriptions

Row 5

For example, the Measurement Group CONTAINER may be instantiated once for each eye, or multiple times for a trend series for a single eye.

Row 20

May be a reference to an Ophthalmic Visual Field Static Perimetry Measurements SOP Instance.

Rows 21, 22

May be a reference to a Secondary Capture Image (row 21) or Encapsulated PDF (row 22) rendering of the set of measurements and findings encoded in this Measurement Group, and possibly additional data.

DICOM PS3.16 2026d - Content Mapping Resource