TID 2002 Report Narrative

The Report Narrative allows recording of text, code, and numeric observations. The order of Content Items in the Template is not significant; the order of Content Items in a SOP Instance may be significant to the narrative flow of the report.

Type:

Non-Extensible

Order:

Non-Significant

Root:

No

Table TID 2002. Report Narrative

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINS

CODE

BCID 7002 “Diagnostic Imaging Report Element”

1-n

U

2

>

INFERRED FROM

INCLUDE

DTID 2001 “Basic Diagnostic Imaging Report Observations”

1-n

U

3

CONTAINS

TEXT

BCID 7002 “Diagnostic Imaging Report Element”

1-n

U

4

>

INFERRED FROM

INCLUDE

DTID 2001 “Basic Diagnostic Imaging Report Observations”

1-n

U

5

CONTAINS

INCLUDE

DTID 2001 “Basic Diagnostic Imaging Report Observations”

1-n

U