DICOM PS3.16 2022b - Content Mapping Resource |
---|
The Procedure Log Template is intended for the representation of reports or logs of time-stamped events occurring during an image-guided interventional or other procedure.
This Template does not require a particular ordering of the subsidiary Content Items.
The Procedure Log IOD (PS3.3) requires ordering by Observation DateTime; thus log entries of different types (i.e., specified by different Rows in the Template) may appear in any order.
While this Template is extensible, the Procedure Log IOD forbids Container Content Items subsidiary to the top level Container.
Includes TID 1002 “Observer Context”, which shall be used to record the identity of the person responsible for recording the log, as well as all other participants in the procedure, even though these personnel may not technically be "observers" of the Procedure Log. As participants in the procedure, they are potential sources for events and observations recorded in the Log. TID 1002 “Observer Context” allows the specification of the person's role in the organization (e.g., physician, nurse), as well as the role in the procedure (e.g., circulating, performing, etc.). |
|
Shall be used to record the identity of the major equipment used in the procedure. |
|
May be used to record any event not covered by a specific log entry Template. |
DICOM PS3.16 2022b - Content Mapping Resource |
---|