DICOM PS3.16 2026d - Content Mapping Resource

CID 6301 Prostate Sector Anatomy from PI-RADS v2

Note

From [PI-RADS].

Resources:

HTML | FHIR JSON | FHIR XML | IHE SVS XML

Keyword:

ProstateSectorAnatomyFromPIRADSv2

FHIR Keyword:

dicom-cid-6301-ProstateSectorAnatomyFromPIRADSv2

Type:

Extensible

Version:

20161106

UID:

1.2.840.10008.6.1.1139

Table CID 6301. Prostate Sector Anatomy from PI-RADS v2

Coding Scheme Designator

Code Value

Code Meaning

SNOMED-RT ID

UMLS Concept Unique ID

FMA ID

PI-RADS v2 Abbreviation

NCI Thesaurus

SCT

716901006

Central zone of left half prostate

R-FFFFC

C4273550

302475

Base L CZ

C128587

SCT

716900007

Central zone of right half prostate

R-FFFD0

C4274157

302473

Base R CZ

C128593

SCT

716937001

Left anterior apical peripheral zone of prostate

R0-00025

C4274170

328760

Apex L PZa

C128575

SCT

716931000

Left anterior apical transition zone of prostate

R-FFFE5

C4274174

328795

Apex L TZa

C128578

SCT

716905002

Left anterior basal peripheral zone of prostate

R0-00001

C4273857

328753

Base L PZa

C128588

SCT

716897000

Left anterior basal transition zone of prostate

R-FFFD6

C4274207

328785

Base L TZa

C128589

SCT

716920008

Left anterior middle peripheral zone of prostate

R-FFFB0

C4274185

328768

Mid L PZa

C128600

SCT

716914007

Left anterior middle transition zone of prostate

R0-00013

C4274190

328784

Mid L TZa

C128603

SCT

716927006

Left apical anterior fibromuscular stroma of prostate

R-FFFDF

C4274178

328772

Apex L AS

C128574

SCT

716893001

Left basal anterior fibromuscular stroma of prostate

R-FFFDC

C4274482

328758

Base L AS

C128586

SCT

716910003

Left middle anterior fibromuscular stroma of prostate

R0-00027

C4274479

328781

Mid L AS

C128599

SCT

716933002

Left posterior apical transition zone of prostate

R0-00014

C4274173

328775

Apex L TZp

C128579

SCT

716899002

Left posterior basal transition zone of prostate

R-FFFB7

C4274204

328789

Base L TZp

C128590

SCT

716916009

Left posterior middle transition zone of prostate

R-FFFAB

C4274189

328786

Mid L TZp

C128604

SCT

716939003

Left posterolateral apical peripheral zone of prostate

R-FFFDD

C4274168

328752

Apex L PZpl

C128576

SCT

716907005

Left posterolateral basal peripheral zone of prostate

R-FFFC2

C4274197

328759

Base L PZpl

C128591

SCT

716922000

Left posterolateral middle peripheral zone of prostate

R-FFFE9

C4274180

328791

Mid L PZpl

C128601

SCT

716941002

Left posteromedial apical peripheral zone of prostate

R0-0000B

C4274166

328792

Apex L PZpm

C128577

SCT

716924004

Left posteromedial middle peripheral zone of prostate

R-FFFB5

C4274183

328777

Mid L PZpm

C128602

SCT

42320003

Left seminal vesicle

T-93020

C0227980

19388

L SV

C128598

SCT

717027004

Male external urethral sphincter

R-FFFD9

C4274093

19733

US

C128612

SCT

716936005

Right anterior apical peripheral zone of prostate

R0-00003

C4274125

328779

Apex R PZa

C128581

SCT

716930004

Right anterior apical transition zone of prostate

R0-00006

C4274131

328761

Apex R TZa

C128584

SCT

716904003

Right anterior basal peripheral zone of prostate

R-FFFE2

C4274200

328798

Base R PZa

C128594

SCT

716896009

Right anterior basal transition zone of prostate

R0-00000

C4273547

328793

Base R TZa

C128596

SCT

716919002

Right anterior middle peripheral zone of prostate

R-FFFCD

C4274141

328796

Mid R PZa

C128606

SCT

716913001

Right anterior middle transition zone of prostate

R-FFFF4

C4274147

328800

Mid R TZa

C128609

SCT

716926002

Right apical anterior fibromuscular stroma of prostate

R-FFFFD

C4273870

328801

Apex R AS

C128580

SCT

716892006

Right basal anterior fibromuscular stroma of prostate

R-FFFF2

C4273849

328778

Base R AS

C128592

SCT

716909008

Right middle anterior fibromuscular stroma of prostate

R0-00004

C4273544

328783

Mid R AS

C128605

SCT

716932007

Right posterior apical transition zone of prostate

R-FFFF3

C4274099

328763

Apex R TZp

C128585

SCT

716898005

Right posterior basal transition zone of prostate

R-FFFB1

C4274205

328799

Base R TZp

C128597

SCT

716915008

Right posterior middle transition zone of prostate

R-FFFC9

C4273542

328787

Mid R TZp

C128610

SCT

716938006

Right posterolateral apical peripheral zone of prostate

R-FFFC0

C4273861

328782

Apex R PZpl

C128582

SCT

716906001

Right posterolateral basal peripheral zone of prostate

R0-0001E

C4274198

328797

Base R PZpl

C128595

SCT

716921007

Right posterolateral middle peripheral zone of prostate

R0-0000C

C4274184

328771

Mid R PZpl

C128607

SCT

716940001

Right posteromedial apical peripheral zone of prostate

R-FFFEA

C4274167

328764

Apex R PZpm

C128583

SCT

716923005

Right posteromedial middle peripheral zone of prostate

R-FFFD4

C4274181

328766

Mid R PZpm

C128608

SCT

74308000

Right seminal vesicle

T-93010

C0227979

19387

R SV

C128611


DICOM PS3.16 2026d - Content Mapping Resource