DICOM PS3.16 2026b - Content Mapping Resource

CID 5 Transducer Approach

Resources:

HTML | FHIR JSON | FHIR XML | IHE SVS XML

Keyword:

TransducerApproach

FHIR Keyword:

dicom-cid-5-TransducerApproach

Type:

Extensible

Version:

20220628

UID:

1.2.840.10008.6.1.3

Table CID 5. Transducer Approach

Coding Scheme Designator

Code Value

Code Meaning

SNOMED-RT ID

UMLS Concept Unique ID

SCT

24028007

Right

G-A100

C0205090

SCT

7771000

Left

G-A101

C0205091

SCT

49370004

Lateral

G-A104

C0205093

SCT

255549009

Anterior

R-404CC

C1704448

SCT

255551008

Posterior

R-404CE

C0205095

SCT

3583002

Caudal

G-A108

C0205097

SCT

255561001

Medial

R-404D5

C0205098

SCT

26216008

Central

G-A110

C0205099

SCT

14414005

Peripheral

G-A111

C0205100

SCT

261074009

External

R-40941

C0205101

SCT

260521003

Internal

R-40819

C0205102

SCT

261089000

Inferior

R-4094A

C0542339

SCT

264217000

Superior

R-42191

C1282910

SCT

62824007

Transverse

G-A117

C0205106

SCT

40415009

Proximal

G-A118

C0205107

SCT

46053002

Distal

G-A119

C0205108

SCT

43674008

Apical

G-A122

C0205111

SCT

410679008

Surface

G-A206

C0205148

SCT

79458005

Ascending

G-A599

C0205385

SCT

75294000

Descending

G-A600

C0205386

SCT

71966008

Subcutaneous tissue

T-03000

C0278403

SCT

18545000

Dura mater

T-A1120

C0013313

SCT

23180006

Pia mater

T-A1280

C0031869

SCT

102322008

External prosthesis for sonographic procedure [Stand-off]

A-2C600

C0522650

SCT

102323003

Water bag prosthesis for imaging procedure

A-2C602

C0522651

SCT

102324009

Saline bag prosthesis for imaging procedure

A-2C604

C0522652

SCT

102325005

Gel prosthesis for imaging procedure

A-2C606

C0522653

SCT

66787007

Cranial

G-A107

C0205096

SCT

261129000

Midline

G-A10A

C0441992

SCT

103342007

Mid-longitudinal

G-A188

C0522490

SCT

103343002

Parasagittal

G-A189

C0522491

SCT

264045001

Intraluminal

R-42142

C0442115

SCT

11070000

Capsular

G-A171

C0205151

SCT

113342003

Lumen

T-D0048

C0524461

SCT

11723008

Contact with

G-4022

C0332158

SCT

91772007

Parenchyma

T-D0062

C0524464

SCT

1197041002

Intercostal

SCT

264208000

Subcostal

R-4218D

C0442184

SCT

117133000

First Intercostal Space

T-D3141

C0446477

SCT

117134006

Second Intercostal Space

T-D3142

C0446478

SCT

117135007

Third Intercostal Space

T-D3143

C0446479

SCT

117136008

Fourth Intercostal Space

T-D3144

C0446480

SCT

117137004

Fifth Intercostal Space

T-D3145

C0446481

SCT

117138009

Sixth Intercostal Space

T-D3146

C0446486

SCT

117139001

Seventh Intercostal Space

T-D3147

C0446482

SCT

117140004

Eighth Intercostal Space

T-D3148

C0446483

SCT

117141000

Ninth Intercostal Space

T-D3149

C0446484

SCT

117142007

Tenth Intercostal Space

T-D314A

C0446487

SCT

117143002

Eleventh Intercostal Space

T-D314B

C0446485


Note

In a prior version of this Context Group, the codes G-A11A, G-A11B, G-A12A, G-A16A, G-A16B, G-A16C, and G-A16D were specified for various concepts. The use of some of those codes conflicts with their assignment to other concepts in SNOMED, and their use in this context is deprecated. Although there is minimal possibility of misinterpretation with SOP Instances that may include the deprecated use, receiving applications should be aware of this change; see Annex J.

DICOM PS3.16 2026b - Content Mapping Resource