CID 3687 Electrophysiology Waveform Durations
This Context Group consists of the per-lead terms under the hierarchy of Reference ID MDC_ECG_TIME_PD in the ISO/IEEE 11073-10102 nomenclature.
The base terms from that hierarchy are included in the table below for reference. The per-lead base terms are pre-coordinated with concept discriminators for specific leads, and the code values for those pre-coordinated terms are arithmetically derived from the code values of the base terms. For the complete current list of terms and discriminator values, see the ISO/IEEE Standard. All pre-coordinated terms (measurements plus discriminators) within the identified hierarchy are part of this Context Group.
Note
-
A prior version of this context group used codes from the SCP-ECG coding system.
-
Codes reprinted by permission of IEEE, Copyright 2004 by IEEE. ISO/IEEE 11073-10102 available through http://standards.ieee.org/.
Table CID 3687. Electrophysiology Waveform Durations
Coding Scheme Designator
|
Code Value
|
Code Meaning
|
ISO/IEEE 11073 MDC Equivalent Reference ID (Informative)
|
MDC
|
2:6656
|
P duration, per lead
|
MDC_ECG_TIME_PD_P
|
MDC
|
2:4608
|
P onset to P1 duration, per lead
|
MDC_ECG_TIME_PD_P1
|
MDC
|
2:4864
|
P onset to P2 duration, per lead
|
MDC_ECG_TIME_PD_P2
|
MDC
|
2:5120
|
P onset to P3 duration, per lead
|
MDC_ECG_TIME_PD_P3
|
MDC
|
2:7168
|
P offset to QRS onset duration, per lead
|
MDC_ECG_TIME_PD_PR
|
MDC
|
2:7680
|
Q duration, per lead
|
MDC_ECG_TIME_PD_Q
|
MDC
|
2:7936
|
QRS duration, per lead
|
MDC_ECG_TIME_PD_QRS
|
MDC
|
2:8192
|
QT duration, per lead
|
MDC_ECG_TIME_PD_QT
|
MDC
|
2:11264
|
R1 duration, per lead
|
MDC_ECG_TIME_PD_R_1
|
MDC
|
2:11520
|
R2 duration, per lead
|
MDC_ECG_TIME_PD_R_2
|
MDC
|
2:11776
|
R3 duration, per lead
|
MDC_ECG_TIME_PD_R_3
|
MDC
|
2:12032
|
S1 duration, per lead
|
MDC_ECG_TIME_PD_S_1
|
MDC
|
2:12288
|
S2 duration, per lead
|
MDC_ECG_TIME_PD_S_2
|
MDC
|
2:12544
|
S3 duration, per lead
|
MDC_ECG_TIME_PD_S_3
|
MDC
|
2:11008
|
Ventricular activation time, per lead
|
MDC_ECG_TIME_PD_VENT_ACTIV
|
MDC
|
2:32768
|
PP time period, per lead
|
MDC_ECG_TIME_PD_PP
|
MDC
|
2:33024
|
RR time period, per lead
|
MDC_ECG_TIME_PD_RR
|
MDC
|
2:33280
|
PQ time period, per lead
|
MDC_ECG_TIME_PD_PQ
|
MDC
|
2:33536
|
PQ segment time period, per lead
|
MDC_ECG_TIME_PD_PQ_SEG
|
MDC
|
2:34560
|
QTU time period, per lead
|
MDC_ECG_TIME_PD_QTU
|