DICOM PS3.16 2026c - Content Mapping Resource

CID 3230 ECG Finding

Note

MDC Codes reprinted by permission of IEEE, Copyright 2004 by IEEE. ISO/IEEE 11073-10102 available through http://standards.ieee.org/.

Resources:

HTML | FHIR JSON | FHIR XML | IHE SVS XML

Keyword:

ECGFinding

FHIR Keyword:

dicom-cid-3230-ECGFinding

Type:

Extensible

Version:

20230630

UID:

1.2.840.10008.6.1.776

Table CID 3230. ECG Finding

Coding Scheme Designator

Code Value

Code Meaning

SNOMED-RT ID

UMLS Concept Unique ID

ISO/IEEE 11073 MDC Equivalent Reference ID (Informative)

SCT

164854000

Normal

F-000B7

C0522054

MDC_ECG_BEAT_NORMAL

SCT

284470004

Atrial premature contraction

D3-30A03

C0033036

MDC_ECG_BEAT_ATR_P_C

SCT

251175005

Ventricular premature contraction

D3-30904

C0151636

MDC_ECG_BEAT_V_P_C

SCT

49436004

Atrial Fibrillation

D3-31520

C0004238

MDC_ECG_RHY_ATR_FIB

SCT

6456007

Supraventricular Tachycardia

D3-31290

C0039240

MDC_ECG_RHY_SV_TACHY

SCT

66657009

Non-sustained ventricular tachycardia

D3-31710

C0030591

MDC_ECG_RHY_V_TACHY_PAROX

SCT

25569003

Ventricular tachycardia

D3-31700

C0042514

MDC_ECG_RHY_V_TACHY

SCT

71908006

Ventricular fibrillation

D3-31720

C0042510

MDC_ECG_RHY_V_FIB

SCT

4554005

Intraventricular conduction disturbance

D3-33000

C0264909

MDC_ECG_BEAT_BLK_IVCD

SCT

63467002

Left bundle branch block

D3-33120

C0023211

MDC_ECG_BEAT_LBB_BLK_COMP

SCT

59118001

Right bundle branch block

D3-33110

C0085615

MDC_ECG_BEAT_RBB_BLK_COMP

SCT

251120003

Incomplete Left bundle branch block

D3-33122

C0281878

MDC_ECG_BEAT_LBB_BLK_INCOMP

SCT

251124007

Incomplete Right bundle branch block

D3-33112

C0262525

MDC_ECG_BEAT_RBB_BLK_INCOMP

SCT

74021003

Bifascicular Block

D3-33200

C0264914

MDC_ECG_BEAT_BLK_BIFASC

SCT

37760005

Left anterior fascicular block

D3-33140

C0264912

MDC_ECG_BEAT_BLK_ANT_L_HEMI

SCT

62026008

Left posterior fascicular block

D3-33150

C0264913

MDC_ECG_BEAT_BLK_POS_L_HEMI

SCT

270492004

First degree Atrioventricular block

D3-30001

C0085614

MDC_ECG_RHY_AV_HEART_BLK_DEG_1

SCT

195042002

Second degree Atrioventricular block

R-F81AE

C0264906

MDC_ECG_RHY_AV_HEART_BLK_DEG_2

SCT

27885002

Third degree Atrioventricular block

D3-32102

C0151517

MDC_ECG_RHY_AV_HEART_BLK_DEG_3

SCT

195060002

Ventricular pre-excitation

D3-31351

C0559106

MDC_ECG_BEAT_PREX

SCT

26141007

ST depression

F-38278

C0520887

SCT

76388001

ST elevation

F-38277

C0520886

SCT

428417006

Early repolarization

F-380B3

C1997354

SCT

428750005

Nonspecific ST-T abnormality

F-38794

C1997940

SCT

428549008

Secondary ST-T abnormality

F-38793

C1998291