DICOM PS3.16 2026b - Content Mapping Resource

CID 3031 Lead Location Near or in Muscle

This Context Group comprises the EMG lead identifiers of ISO/IEEE 11073-10101. The terms included in the table below may not constitute the complete list; see the ISO/IEEE Standard.

Note

Codes reprinted by permission of IEEE, Copyright 2004 by IEEE. ISO/IEEE 11073-10102 available through http://standards.ieee.org/.

Resources:

HTML | FHIR JSON | FHIR XML | IHE SVS XML

Keyword:

LeadLocationNearOrInMuscle

FHIR Keyword:

dicom-cid-3031-LeadLocationNearOrInMuscle

Type:

Extensible

Version:

20200623

UID:

1.2.840.10008.6.1.1329

Table CID 3031. Lead Location Near or in Muscle

Coding Scheme Designator

Code Value

Code Meaning

ISO/IEEE 11073 MDC Equivalent Reference ID (Informative)

MDC

7:252

Musculi capitis

MDC_MUSC_HEAD

MDC

7:253

Musculi capitis, left

MDC_MUSC_HEAD_L

MDC

7:254

Musculi capitis, right

MDC_MUSC_HEAD_R

MDC

7:256

Musculi bulbi

MDC_MUSC_HEAD_EYE

MDC

7:257

Musculi bulbi, left

MDC_MUSC_HEAD_EYE_L

MDC

7:258

Musculi bulbi, right

MDC_MUSC_HEAD_EYE_R

MDC

7:260

Musculus rectus superior

MDC_MUSC_HEAD_RECT_SUP

MDC

7:261

Musculus rectus superior, left

MDC_MUSC_HEAD_RECT_SUP_L

MDC

7:262

Musculus rectus superior, right

MDC_MUSC_HEAD_RECT_SUP_R

MDC

7:264

Musculus rectus inferior

MDC_MUSC_HEAD_RECT_INF

MDC

7:265

Musculus rectus inferior, left

MDC_MUSC_HEAD_RECT_INF_L

MDC

7:266

Musculus rectus inferior, right

MDC_MUSC_HEAD_RECT_INF_R

MDC

7:268

Musculus rectus medialis

MDC_MUSC_HEAD_RECT_MED

MDC

7:269

Musculus rectus medialis, left

MDC_MUSC_HEAD_RECT_MED_L

MDC

7:270

Musculus rectus medialis, right

MDC_MUSC_HEAD_RECT_MED_R

MDC

7:272

Musculus rectus lateralis

MDC_MUSC_HEAD_RECT_LAT

MDC

7:273

Musculus rectus lateralis, left

MDC_MUSC_HEAD_RECT_LAT_L

MDC

7:274

Musculus rectus lateralis, right

MDC_MUSC_HEAD_RECT_LAT_R

MDC

7:276

Musculus obliquus superior

MDC_MUSC_HEAD_OBLIQ_SUP

MDC

7:277

Musculus obliquus superior, left

MDC_MUSC_HEAD_OBLIQ_SUP_L

MDC

7:278

Musculus obliquus superior, right

MDC_MUSC_HEAD_OBLIQ_SUP_R

MDC

7:280

Musculus obliquus inferior

MDC_MUSC_HEAD_OBLIQ_INF

MDC

7:281

Musculus obliquus inferior, left

MDC_MUSC_HEAD_OBLIQ_INF_L

MDC

7:282

Musculus obliquus inferior, right

MDC_MUSC_HEAD_OBLIQ_INF_R

MDC

7:284

Musculi faciales et masticatores

MDC_MUSC_HEAD_FACIAL

MDC

7:285

Musculi faciales et masticatores, left

MDC_MUSC_HEAD_FACIAL_L

MDC

7:286

Musculi faciales et masticatores, right

MDC_MUSC_HEAD_FACIAL_R

MDC

7:288

Musculus occipitofrontalis, Venter frontalis

MDC_MUSC_HEAD_OCCIPITOFRONT_VENTER

MDC

7:289

Musculus occipitofrontalis, Venter frontalis, left

MDC_MUSC_HEAD_OCCIPITOFRONT_VENTER_L

MDC

7:290

Musculus occipitofrontalis, Venter frontalis, right

MDC_MUSC_HEAD_OCCIPITOFRONT_VENTER_R

MDC

7:292

Musculus orbicularis oculi

MDC_MUSC_HEAD_ORBIC_OCUL

MDC

7:293

Musculus orbicularis oculi, left

MDC_MUSC_HEAD_ORBIC_OCUL_L

MDC

7:294

Musculus orbicularis oculi, right

MDC_MUSC_HEAD_ORBIC_OCUL_R

MDC

7:296

Musculus orbicularis oculi, Pars orbitalis

MDC_MUSC_HEAD_ORBIC_OCUL_PARS_ORBIT

MDC

7:297

Musculus orbicularis oculi, Pars orbitalis, left

MDC_MUSC_HEAD_ORBIC_OCUL_PARS_ORBIT_L

MDC

7:298

Musculus orbicularis oculi, Pars orbitalis, right

MDC_MUSC_HEAD_ORBIC_OCUL_PARS_ORBIT_R

MDC

7:300

Musculus auricularis posterior

MDC_MUSC_HEAD_AURIC_POST

MDC

7:301

Musculus auricularis posterior, left

MDC_MUSC_HEAD_AURIC_POST_L

MDC

7:302

Musculus auricularis posterior, right

MDC_MUSC_HEAD_AURIC_POST_R

MDC

7:304

Musculus orbicularis oris

MDC_MUSC_HEAD_ORBIC_ORIS

MDC

7:305

Musculus orbicularis oris, left

MDC_MUSC_HEAD_ORBIC_ORIS_L

MDC

7:306

Musculus orbicularis oris, right

MDC_MUSC_HEAD_ORBIC_ORIS_R

MDC

7:308

Musculus depressor anguli oris

MDC_MUSC_HEAD_DEPRESSOR_ANGUL_ORIS

MDC

7:309

Musculus depressor anguli oris, left

MDC_MUSC_HEAD_DEPRESSOR_ANGUL_ORIS_L

MDC

7:310

Musculus depressor anguli oris, right

MDC_MUSC_HEAD_DEPRESSOR_ANGUL_ORIS_R

MDC

7:312

Musculus risorius

MDC_MUSC_HEAD_RISOR

MDC

7:313

Musculus risorius, left

MDC_MUSC_HEAD_RISOR_L

MDC

7:314

Musculus risorius, right

MDC_MUSC_HEAD_RISOR_R

MDC

7:316

Musculus zygomaticus major

MDC_MUSC_HEAD_ZYGOMATIC_MAJOR

MDC

7:317

Musculus zygomaticus major, left

MDC_MUSC_HEAD_ZYGOMATIC_MAJOR_L

MDC

7:318

Musculus zygomaticus major, right

MDC_MUSC_HEAD_ZYGOMATIC_MAJOR_R

MDC

7:320

Musculus zygomaticus minor

MDC_MUSC_HEAD_ZYGOMATIC_MINOR

MDC

7:321

Musculus zygomaticus minor, left

MDC_MUSC_HEAD_ZYGOMATIC_MINOR_L

MDC

7:322

Musculus zygomaticus minor, right

MDC_MUSC_HEAD_ZYGOMATIC_MINOR_R

MDC

7:324

Musculus levator labii superioris

MDC_MUSC_HEAD_LEVATOR_LAB_SUP

MDC

7:325

Musculus levator labii superioris, left

MDC_MUSC_HEAD_LEVATOR_LAB_SUP_L

MDC

7:326

Musculus levator labii superioris, right

MDC_MUSC_HEAD_LEVATOR_LAB_SUP_R

MDC

7:328

Musculus levator labii superioris alaeque nasi

MDC_MUSC_HEAD_LEVATOR_LAB_SUP_AL_NASI

MDC

7:329

Musculus levator labii superioris alaeque nasi, left

MDC_MUSC_HEAD_LEVATOR_LAB_SUP_AL_NASI_L

MDC

7:330

Musculus levator labii superioris alaeque nasi, right

MDC_MUSC_HEAD_LEVATOR_LAB_SUP_AL_NASI_R

MDC

7:332

Musculus depressor labii inferioris

MDC_MUSC_HEAD_DEPRESSOR_LAB_INF

MDC

7:333

Musculus depressor labii inferioris, left

MDC_MUSC_HEAD_DEPRESSOR_LAB_INF_L

MDC

7:334

Musculus depressor labii inferioris, right

MDC_MUSC_HEAD_DEPRESSOR_LAB_INF_R

MDC

7:336

Musculus levator anguli oris

MDC_MUSC_HEAD_LEVATOR_ANGUL_ORIS

MDC

7:337

Musculus levator anguli oris, left

MDC_MUSC_HEAD_LEVATOR_ANGUL_ORIS_L

MDC

7:338

Musculus levator anguli oris, right

MDC_MUSC_HEAD_LEVATOR_ANGUL_ORIS_R

MDC

7:340

Musculus buccinator

MDC_MUSC_HEAD_BUCCINATOR

MDC

7:341

Musculus buccinator, left

MDC_MUSC_HEAD_BUCCINATOR_L

MDC

7:342

Musculus buccinator, right

MDC_MUSC_HEAD_BUCCINATOR_R

MDC

7:344

Musculus mentalis

MDC_MUSC_HEAD_MENTAL

MDC

7:345

Musculus mentalis, left

MDC_MUSC_HEAD_MENTAL_L

MDC

7:346

Musculus mentalis, right

MDC_MUSC_HEAD_MENTAL_R

MDC

7:348

Musculus masseter

MDC_MUSC_HEAD_MASSETER

MDC

7:349

Musculus masseter, left

MDC_MUSC_HEAD_MASSETER_L

MDC

7:350

Musculus masseter, right

MDC_MUSC_HEAD_MASSETER_R

MDC

7:352

Musculus temporalis

MDC_MUSC_HEAD_TEMPOR

MDC

7:353

Musculus temporalis, left

MDC_MUSC_HEAD_TEMPOR_L

MDC

7:354

Musculus temporalis, right

MDC_MUSC_HEAD_TEMPOR_R

MDC

7:356

Musculus Pterygoideus

MDC_MUSC_HEAD_PTERYGOID

MDC

7:357

Musculus Pterygoideus, left

MDC_MUSC_HEAD_PTERYGOID_L

MDC

7:358

Musculus Pterygoideus, right

MDC_MUSC_HEAD_PTERYGOID_R

MDC

7:360

Musculus Pterygoideus lateralis

MDC_MUSC_HEAD_PTERYGOID_LAT

MDC

7:361

Musculus Pterygoideus lateralis, left

MDC_MUSC_HEAD_PTERYGOID_LAT_L

MDC

7:362

Musculus Pterygoideus lateralis, right

MDC_MUSC_HEAD_PTERYGOID_LAT_R

MDC

7:364

Musculus Pterygoideus, medialis

MDC_MUSC_HEAD_PTERYGOID_MED

MDC

7:365

Musculus Pterygoideus, medialis, left

MDC_MUSC_HEAD_PTERYGOID_MED_L

MDC

7:366

Musculus Pterygoideus, medialis, right

MDC_MUSC_HEAD_PTERYGOID_MED_R

MDC

7:368

Musculi linguae

MDC_MUSC_HEAD_LING

MDC

7:369

Musculi linguae, left

MDC_MUSC_HEAD_LING_L

MDC

7:370

Musculi linguae, right

MDC_MUSC_HEAD_LING_R

MDC

7:372

Musculus genioglossus

MDC_MUSC_HEAD_GENIOGLOSS

MDC

7:373

Musculus genioglossus, left

MDC_MUSC_HEAD_GENIOGLOSS_L

MDC

7:374

Musculus genioglossus, right

MDC_MUSC_HEAD_GENIOGLOSS_R

MDC

7:376

Musculi laringis

MDC_MUSC_HEAD_LARING

MDC

7:377

Musculi laringis, left

MDC_MUSC_HEAD_LARING_L

MDC

7:378

Musculi laringis, right

MDC_MUSC_HEAD_LARING_R

MDC

7:380

Musculus cricothyroideus

MDC_MUSC_HEAD_CRICOTHYROID

MDC

7:381

Musculus cricothyroideus, left

MDC_MUSC_HEAD_CRICOTHYROID_L

MDC

7:382

Musculus cricothyroideus, right

MDC_MUSC_HEAD_CRICOTHYROID_R

MDC

7:384

Musculus tyroartenoideus

MDC_MUSC_HEAD_THYROARYTEROID

MDC

7:385

Musculus tyroartenoideus, left

MDC_MUSC_HEAD_THYROARYTEROID_L

MDC

7:386

Musculus tyroartenoideus, right

MDC_MUSC_HEAD_THYROARYTEROID_R

MDC

7:388

Musculi colli

MDC_MUSC_NECK

MDC

7:389

Musculi colli, left

MDC_MUSC_NECK_L

MDC

7:390

Musculi colli, right

MDC_MUSC_NECK_R

MDC

7:392

Platysma

MDC_MUSC_NECK_PLATYSMA

MDC

7:393

Platysma, left

MDC_MUSC_NECK_PLATYSMA_L

MDC

7:394

Platysma, right

MDC_MUSC_NECK_PLATYSMA_R

MDC

7:396

Musculus capitis longus

MDC_MUSC_NECK_CAPT_LONG

MDC

7:397

Musculus capitis longus, left

MDC_MUSC_NECK_CAPT_LONG_L

MDC

7:398

Musculus capitis longus, right

MDC_MUSC_NECK_CAPT_LONG_R

MDC

7:400

Musculus Sternocleidomastoideus

MDC_MUSC_NECK_STERNOCLEIDOMASTOID

MDC

7:401

Musculus Sternocleidomastoideus, left

MDC_MUSC_NECK_STERNOCLEIDOMASTOID_L

MDC

7:402

Musculus Sternocleidomastoideus, right

MDC_MUSC_NECK_STERNOCLEIDOMASTOID_R

MDC

7:404

Musculus digastricus

MDC_MUSC_NECK_DIGRASTRIC

MDC

7:405

Musculus digastricus, left

MDC_MUSC_NECK_DIGRASTRIC_L

MDC

7:406

Musculus digastricus, right

MDC_MUSC_NECK_DIGRASTRIC_R

MDC

7:408

Musculus digastricus, Venter anterior

MDC_MUSC_NECK_DIGRASTRIC_VENTER_ANT

MDC

7:409

Musculus digastricus, Venter anterior, left

MDC_MUSC_NECK_DIGRASTRIC_VENTER_ANT_L

MDC

7:410

Musculus digastricus, Venter anterior, right

MDC_MUSC_NECK_DIGRASTRIC_VENTER_ANT_R

MDC

7:412

Musculus digastricus, Venter posterior

MDC_MUSC_NECK_DIGRASTRIC_VENTER_POST

MDC

7:413

Musculus digastricus, Venter posterior, left

MDC_MUSC_NECK_DIGRASTRIC_VENTER_POST_L

MDC

7:414

Musculus digastricus, Venter posterior, right

MDC_MUSC_NECK_DIGRASTRIC_VENTER_POST_R

MDC

7:416

Musculus mylohyoideus

MDC_MUSC_NECK_MYLOHYOID

MDC

7:417

Musculus mylohyoideus, left

MDC_MUSC_NECK_MYLOHYOID_L

MDC

7:418

Musculus mylohyoideus, right

MDC_MUSC_NECK_MYLOHYOID_R

MDC

7:424

Musculi dorsi

MDC_MUSC_BACK

MDC

7:425

Musculi dorsi, left

MDC_MUSC_BACK_L

MDC

7:426

Musculi dorsi, right

MDC_MUSC_BACK_R

MDC

7:436

Musculus trapezius

MDC_MUSC_BACK_TRAPEZ

MDC

7:437

Musculus trapezius, left

MDC_MUSC_BACK_TRAPEZ_L

MDC

7:438

Musculus trapezius, right

MDC_MUSC_BACK_TRAPEZ_R

MDC

7:440

Musculus latissimus dorsi

MDC_MUSC_BACK_LASTISSIM_DORS

MDC

7:441

Musculus latissimus dorsi, left

MDC_MUSC_BACK_LASTISSIM_DORS_L

MDC

7:442

Musculus latissimus dorsi, right

MDC_MUSC_BACK_LASTISSIM_DORS_R

MDC

7:444

Musculus rhomboideus major

MDC_MUSC_BACK_RHOMB_MAJOR

MDC

7:445

Musculus rhomboideus major, left

MDC_MUSC_BACK_RHOMB_MAJOR_L

MDC

7:446

Musculus rhomboideus major, right

MDC_MUSC_BACK_RHOMB_MAJOR_R

MDC

7:448

Musculus rhomboideus minor

MDC_MUSC_BACK_RHOMB_MINOR

MDC

7:449

Musculus rhomboideus minor, left

MDC_MUSC_BACK_RHOMB_MINOR_L

MDC

7:450

Musculus rhomboideus minor, right

MDC_MUSC_BACK_RHOMB_MINOR_R

MDC

7:452

Musculus levator scapulae

MDC_MUSC_BACK_SCAP_LEVATOR

MDC

7:453

Musculus levator scapulae, left

MDC_MUSC_BACK_SCAP_LEVATOR_L

MDC

7:454

Musculus levator scapulae, right

MDC_MUSC_BACK_SCAP_LEVATOR_R

MDC

7:456

Musculus serratus posterior

MDC_MUSC_BACK_SERRAT_POST

MDC

7:457

Musculus serratus posterior, left

MDC_MUSC_BACK_SERRAT_POST_L

MDC

7:458

Musculus serratus posterior, right

MDC_MUSC_BACK_SERRAT_POST_R

MDC

7:460

Musculus splenius capitis

MDC_MUSC_BACK_SPLEN_CAPT

MDC

7:461

Musculus splenius capitis, left

MDC_MUSC_BACK_SPLEN_CAPT_L

MDC

7:462

Musculus splenius capitis, right

MDC_MUSC_BACK_SPLEN_CAPT_R

MDC

7:464

Musculus splenius cervicis

MDC_MUSC_BACK_SPLEN_CERVIC

MDC

7:465

Musculus splenius cervicis, left

MDC_MUSC_BACK_SPLEN_CERVIC_L

MDC

7:466

Musculus splenius cervicis, right

MDC_MUSC_BACK_SPLEN_CERVIC_R

MDC

7:468

Musculus splenius

MDC_MUSC_BACK_SPLEN

MDC

7:469

Musculus splenius, left

MDC_MUSC_BACK_SPLEN_L

MDC

7:470

Musculus splenius, right

MDC_MUSC_BACK_SPLEN_R

MDC

7:472

Musculus erector spinae

MDC_MUSC_BACK_SPINAL_ERECTOR

MDC

7:473

Musculus erector spinae, left

MDC_MUSC_BACK_SPINAL_ERECTOR_L

MDC

7:474

Musculus erector spinae, right

MDC_MUSC_BACK_SPINAL_ERECTOR_R

MDC

7:476

Musculus spinalis

MDC_MUSC_BACK_SPINAL

MDC

7:477

Musculus spinalis, left

MDC_MUSC_BACK_SPINAL_L

MDC

7:478

Musculus spinalis, right

MDC_MUSC_BACK_SPINAL_R

MDC

7:480

Musculus spinalis thoracis

MDC_MUSC_BACK_SPINAL_THORAC

MDC

7:481

Musculus spinalis thoracis, left

MDC_MUSC_BACK_SPINAL_THORAC_L

MDC

7:482

Musculus spinalis thoracis, right

MDC_MUSC_BACK_SPINAL_THORAC_R

MDC

7:484

Musculus spinalis cervicis

MDC_MUSC_BACK_SPINAL_CERVIC

MDC

7:485

Musculus spinalis cervicis, left

MDC_MUSC_BACK_SPINAL_CERVIC_L

MDC

7:486

Musculus spinalis cervicis, right

MDC_MUSC_BACK_SPINAL_CERVIC_R

MDC

7:488

Musculus spinalis capitis

MDC_MUSC_BACK_SPINAL_CAPIT

MDC

7:489

Musculus spinalis capitis, left

MDC_MUSC_BACK_SPINAL_CAPIT_L

MDC

7:490

Musculus spinalis capitis, right

MDC_MUSC_BACK_SPINAL_CAPIT_R

MDC

7:492

Musculus semispinalis

MDC_MUSC_BACK_SEMISPINAL

MDC

7:493

Musculus semispinalis, left

MDC_MUSC_BACK_SEMISPINAL_L

MDC

7:494

Musculus semispinalis, right

MDC_MUSC_BACK_SEMISPINAL_R

MDC

7:496

Musculus semispinalis thoracis

MDC_MUSC_BACK_SEMISPINAL_THOR

MDC

7:497

Musculus semispinalis thoracis, left

MDC_MUSC_BACK_SEMISPINAL_THOR_L

MDC

7:498

Musculus semispinalis thoracis, right

MDC_MUSC_BACK_SEMISPINAL_THOR_R

MDC

7:500

Musculus semispinalis cervicis

MDC_MUSC_BACK_SEMISPINAL_CERV

MDC

7:501

Musculus semispinalis cervicis, left

MDC_MUSC_BACK_SEMISPINAL_CERV_L

MDC

7:502

Musculus semispinalis cervicis, right

MDC_MUSC_BACK_SEMISPINAL_CERV_R

MDC

7:504

Musculus semispinalis capitis

MDC_MUSC_BACK_SEMISPINAL_CAPIT

MDC

7:505

Musculus semispinalis capitis, left

MDC_MUSC_BACK_SEMISPINAL_CAPIT_L

MDC

7:506

Musculus semispinalis capitis, right

MDC_MUSC_BACK_SEMISPINAL_CAPIT_R

MDC

7:508

Musculi multifidii

MDC_MUSC_BACK_MULTIFID

MDC

7:509

Musculi multifidii, left

MDC_MUSC_BACK_MULTIFID_L

MDC

7:510

Musculi multifidii, right

MDC_MUSC_BACK_MULTIFID_R

MDC

7:512

Musculi interspinales

MDC_MUSC_BACK_INTERSPINAL

MDC

7:513

Musculi interspinales, left

MDC_MUSC_BACK_INTERSPINAL_L

MDC

7:514

Musculi interpsinales, right

MDC_MUSC_BACK_INTERSPINAL_R

MDC

7:516

Musculi interspinales cervicis

MDC_MUSC_BACK_INTERSPINAL_CERVIC

MDC

7:517

Musculi interspinales cervicis, left

MDC_MUSC_BACK_INTERSPINAL_CERVIC_L

MDC

7:518

Musculi interspinales cervicis, right

MDC_MUSC_BACK_INTERSPINAL_CERVIC_R

MDC

7:520

Musculi interspinales thoracis

MDC_MUSC_BACK_INTERSPINAL_THORAC

MDC

7:521

Musculi interspinales thoracis, left

MDC_MUSC_BACK_INTERSPINAL_THORAC_L

MDC

7:522

Musculi interspinales thoracis, right

MDC_MUSC_BACK_INTERSPINAL_THORAC_R

MDC

7:524

Musculi interspinales lumborum

MDC_MUSC_BACK_INTERSPINAL_LUMBOR

MDC

7:525

Musculi interspinales lumborum, left

MDC_MUSC_BACK_INTERSPINAL_LUMBOR_L

MDC

7:526

Musculi interspinales lumborum, right

MDC_MUSC_BACK_INTERSPINAL_LUMBOR_R

MDC

7:528

Musculi thoracis

MDC_MUSC_THORAX

MDC

7:529

Musculi thoracis, left

MDC_MUSC_THORAX_L

MDC

7:530

Musculi thoracis, right

MDC_MUSC_THORAX_R

MDC

7:532

Musculus pectoralis major

MDC_MUSC_THORAX_PECTORAL_MAJOR

MDC

7:533

Musculus pectoralis major, left

MDC_MUSC_THORAX_PECTORAL_MAJOR_L

MDC

7:534

Musculus pectoralis major, right

MDC_MUSC_THORAX_PECTORAL_MAJOR_R

MDC

7:536

Musculus pectoralis minor

MDC_MUSC_THORAX_PECTORAL_MINOR

MDC

7:537

Musculus pectoralis minor, left

MDC_MUSC_THORAX_PECTORAL_MINOR_L

MDC

7:538

Musculus pectoralis minor, right

MDC_MUSC_THORAX_PECTORAL_MINOR_R

MDC

7:540

Musculus subclavius

MDC_MUSC_THORAX_SUBCLAV

MDC

7:541

Musculus subclavius, left

MDC_MUSC_THORAX_SUBCLAV_L

MDC

7:542

Musculus subclavius, right

MDC_MUSC_THORAX_SUBCLAV_R

MDC

7:544

Musculus serratus anterior

MDC_MUSC_THORAX_SERRAT_ANT

MDC

7:545

Musculus serratus anterior, left

MDC_MUSC_THORAX_SERRAT_ANT_L

MDC

7:546

Musculus serratus anterior, right

MDC_MUSC_THORAX_SERRAT_ANT_R

MDC

7:548

Musculi intercostales

MDC_MUSC_THORAX_INTERCOSTAL

MDC

7:549

Musculi intercostales, left

MDC_MUSC_THORAX_INTERCOSTAL_L

MDC

7:550

Musculi intercostales, right

MDC_MUSC_THORAX_INTERCOSTAL_R

MDC

7:552

Diaphragma

MDC_MUSC_THORAX_DIAPHRAGM

MDC

7:553

Diaphragma, left

MDC_MUSC_THORAX_DIAPHRAGM_L

MDC

7:554

Diaphragma, right

MDC_MUSC_THORAX_DIAPHRAGM_R

MDC

7:556

Musculi abdominis

MDC_MUSC_ABDOM

MDC

7:557

Musculi abdominis, left

MDC_MUSC_ABDOM_L

MDC

7:558

Musculi abdominis, right

MDC_MUSC_ABDOM_R

MDC

7:560

Musculus rectus abdominis

MDC_MUSC_ABDOM_ABDOMIN

MDC

7:561

Musculus rectus abdominis, left

MDC_MUSC_ABDOM_ABDOMIN_L

MDC

7:562

Musculus rectus abdominis, right

MDC_MUSC_ABDOM_ABDOMIN_R

MDC

7:564

Musculus obliquus externus abdominis

MDC_MUSC_ABDOM_OBLIQ_EXT

MDC

7:565

Musculus obliquus externus abdominis, left

MDC_MUSC_ABDOM_OBLIQ_EXT_L

MDC

7:566

Musculus obliquus externus abdominis, right

MDC_MUSC_ABDOM_OBLIQ_EXT_R

MDC

7:568

Musculus obliquus internus abdominis

MDC_MUSC_ABDOM_OBLIQ_INT

MDC

7:569

Musculus obliquus internus abdominis, left

MDC_MUSC_ABDOM_OBLIQ_INT_L

MDC

7:570

Musculus obliquus internus abdominis, right

MDC_MUSC_ABDOM_OBLIQ_INT_R

MDC

7:572

Musculus transversus abdominis

MDC_MUSC_ABDOM_ABDOM_TRANSVERS

MDC

7:573

Musculus transversus abdominis, left

MDC_MUSC_ABDOM_ABDOM_TRANSVERS_L

MDC

7:574

Musculus transversus abdominis, right

MDC_MUSC_ABDOM_ABDOM_TRANSVERS_R

MDC

7:576

Musculus quadratus lumborum

MDC_MUSC_ABDOM_LUMBOR_QUADRAT

MDC

7:577

Musculus quadratus lumborum, left

MDC_MUSC_ABDOM_LUMBOR_QUADRAT_L

MDC

7:578

Musculus quadratus lumborum, right

MDC_MUSC_ABDOM_LUMBOR_QUADRAT_R

MDC

7:580

Musculi diaphragmatis pelvis

MDC_MUSC_ABDOM_PELV

MDC

7:581

Musculi diaphragmatis pelvis, left

MDC_MUSC_ABDOM_PELV_L

MDC

7:582

Musculi diaphragmatis pelvis, right

MDC_MUSC_ABDOM_PELV_R

MDC

7:584

Musculus puborectalis

MDC_MUSC_ABDOM_PUBORECT

MDC

7:585

Musculus puborectalis, left

MDC_MUSC_ABDOM_PUBORECT_L

MDC

7:586

Musculus puborectalis, right

MDC_MUSC_ABDOM_PUBORECT_R

MDC

7:588

Musculus coccygeus

MDC_MUSC_ABDOM_COCCYG

MDC

7:589

Musculus coccygeus, left

MDC_MUSC_ABDOM_COCCYG_L

MDC

7:590

Musculus coccygeus, right

MDC_MUSC_ABDOM_COCCYG_R

MDC

7:592

Musculus sphincter ani

MDC_MUSC_ABDOM_ANI_SPHINCTER

MDC

7:596

Musculus sphincter ani externus

MDC_MUSC_ABDOM_ANI_SPHINCTER_EXT

MDC

7:600

Musculi membri superioris

MDC_MUSC_UPEXT

MDC

7:601

Musculi membri superioris, left

MDC_MUSC_UPEXT_L

MDC

7:602

Musculi membri superiori, right

MDC_MUSC_UPEXT_R

MDC

7:604

Musculus deltoideus

MDC_MUSC_UPEXT_DELTOID

MDC

7:605

Musculus deltoideus, left

MDC_MUSC_UPEXT_DELTOID_L

MDC

7:606

Musculus deltoideus, right

MDC_MUSC_UPEXT_DELTOID_R

MDC

7:608

Musculus supraspinatus

MDC_MUSC_UPEXT_SUPRASPINAT

MDC

7:609

Musculus supraspinatus, left

MDC_MUSC_UPEXT_SUPRASPINAT_L

MDC

7:610

Musculus supraspinatus, right

MDC_MUSC_UPEXT_SUPRASPINAT_R

MDC

7:612

Musculus infraspinatus

MDC_MUSC_UPEXT_INFRASPINAT

MDC

7:613

Musculus infraspinatus, left

MDC_MUSC_UPEXT_INFRASPINAT_L

MDC

7:614

Musculus infraspinatus, right

MDC_MUSC_UPEXT_INFRASPINAT_R

MDC

7:616

Musculus teres minor

MDC_MUSC_UPEXT_TERES_MINOR

MDC

7:617

Musculus teres minor, left

MDC_MUSC_UPEXT_TERES_MINOR_L

MDC

7:618

Musculus teres minor, right

MDC_MUSC_UPEXT_TERES_MINOR_R

MDC

7:620

Musculus teres major

MDC_MUSC_UPEXT_TERES_MAJOR

MDC

7:621

Musculus teres major, left

MDC_MUSC_UPEXT_TERES_MAJOR_L

MDC

7:622

Musculus teres major, right

MDC_MUSC_UPEXT_TERES_MAJOR_R

MDC

7:624

Musculus subscapularis

MDC_MUSC_UPEXT_SUBSCAP

MDC

7:625

Musculus subscapularis, left

MDC_MUSC_UPEXT_SUBSCAP_L

MDC

7:626

Musculus subscapularis, right

MDC_MUSC_UPEXT_SUBSCAP_R

MDC

7:628

Musculus biceps brachii

MDC_MUSC_UPEXT_BRACHI_BICEPS

MDC

7:629

Musculus biceps brachii, left

MDC_MUSC_UPEXT_BRACHI_BICEPS_L

MDC

7:630

Musculus biceps brachii, right

MDC_MUSC_UPEXT_BRACHI_BICEPS_R

MDC

7:632

Musculus brachialis

MDC_MUSC_UPEXT_BRACHIAL

MDC

7:633

Musculus brachialis, left

MDC_MUSC_UPEXT_BRACHIAL_L

MDC

7:634

Musculus brachialis, right

MDC_MUSC_UPEXT_BRACHIAL_R

MDC

7:636

Musculus coracobrachialis

MDC_MUSC_UPEXT_CORACOBRACH

MDC

7:637

Musculus coracobrachialis, left

MDC_MUSC_UPEXT_CORACOBRACH_L

MDC

7:638

Musculus coracobrachialis, right

MDC_MUSC_UPEXT_CORACOBRACH_R

MDC

7:640

Musculus triceps brachii

MDC_MUSC_UPEXT_BRACH_TRICEPS

MDC

7:641

Musculus triceps brachii, left

MDC_MUSC_UPEXT_BRACH_TRICEPS_L

MDC

7:642

Musculus triceps brachii, right

MDC_MUSC_UPEXT_BRACH_TRICEPS_R

MDC

7:644

Musculus triceps brachii, Caput longum

MDC_MUSC_UPEXT_BRACH_TRICEPS_CAP_LONG

MDC

7:645

Musculus triceps brachii, Caput longum, left

MDC_MUSC_UPEXT_BRACH_TRICEPS_CAP_LONG_L

MDC

7:646

Musculus triceps brachii, Caput longum, right

MDC_MUSC_UPEXT_BRACH_TRICEPS_CAP_LONG_R

MDC

7:648

Musculus triceps brachii, Caput laterale

MDC_MUSC_UPEXT_BRACH_TRICEPS_CAP_LAT

MDC

7:649

Musculus triceps brachii, Caput laterale, left

MDC_MUSC_UPEXT_BRACH_TRICEPS_CAP_LAT_L

MDC

7:650

Musculus triceps brachii, Caput laterale, right

MDC_MUSC_UPEXT_BRACH_TRICEPS_CAP_LAT_R

MDC

7:652

Musculus triceps brachii, Caput mediale

MDC_MUSC_UPEXT_BRACH_TRICEPS_CAP_MED

MDC

7:653

Musculus triceps brachii, Caput mediale, left

MDC_MUSC_UPEXT_BRACH_TRICEPS_CAP_MED_L

MDC

7:654

Musculus triceps brachii, Caput mediale, right

MDC_MUSC_UPEXT_BRACH_TRICEPS_CAP_MED_R

MDC

7:656

Musculus anconeus

MDC_MUSC_UPEXT_ANCON

MDC

7:657

Musculus anconeus, left

MDC_MUSC_UPEXT_ANCON_L

MDC

7:658

Musculus anconeus, right

MDC_MUSC_UPEXT_ANCON_R

MDC

7:660

Musculus pronator teres

MDC_MUSC_UPEXT_PRONATOR

MDC

7:661

Musculus pronator teres, left

MDC_MUSC_UPEXT_PRONATOR_L

MDC

7:662

Musculus pronator teres, right

MDC_MUSC_UPEXT_PRONATOR_R

MDC

7:664

Musculus flexor carpi radialis

MDC_MUSC_UPEXT_FLEX_CARPI_RADIAL

MDC

7:665

Musculus flexor carpi radialis, left

MDC_MUSC_UPEXT_FLEX_CARPI_RADIAL_L

MDC

7:666

Musculus flexor carpi radialis, right

MDC_MUSC_UPEXT_FLEX_CARPI_RADIAL_R

MDC

7:668

Musculus palmaris longus

MDC_MUSC_UPEXT_PALMAR_LONG

MDC

7:669

Musculus palmaris longus, left

MDC_MUSC_UPEXT_PALMAR_LONG_L

MDC

7:670

Musculus palmaris longus, right

MDC_MUSC_UPEXT_PALMAR_LONG_R

MDC

7:672

Musculus flexor carpi ulnaris

MDC_MUSC_UPEXT_FLEX_CARPI_ULNAR

MDC

7:673

Musculus flexor carpi ulnaris, left

MDC_MUSC_UPEXT_FLEX_CARPI_ULNAR_L

MDC

7:674

Musculus flexor carpi ulnaris, right

MDC_MUSC_UPEXT_FLEX_CARPI_ULNAR_R

MDC

7:676

Musculus flexor digitorum superficialis

MDC_MUSC_UPEXT_FLEX_DIGIT_SUPERF

MDC

7:677

Musculus flexor digitorum superficialis, left

MDC_MUSC_UPEXT_FLEX_DIGIT_SUPERF_L

MDC

7:678

Musculus flexor digitorum superficialis, right

MDC_MUSC_UPEXT_FLEX_DIGIT_SUPERF_R

MDC

7:680

Musculus flexor digitorum profundus

MDC_MUSC_UPEXT_FLEX_DIGIT_PROFUND

MDC

7:681

Musculus flexor digitorum profundus, left

MDC_MUSC_UPEXT_FLEX_DIGIT_PROFUND_L

MDC

7:682

Musculus flexor digitorum profundus, right

MDC_MUSC_UPEXT_FLEX_DIGIT_PROFUND_R

MDC

7:684

Musculus flexor pollicis longus

MDC_MUSC_UPEXT_FLEX_POLLIC_LONG

MDC

7:685

Musculus flexor pollicis longus, left

MDC_MUSC_UPEXT_FLEX_POLLIC_LONG_L

MDC

7:686

Musculus flexor pollicis longus, right

MDC_MUSC_UPEXT_FLEX_POLLIC_LONG_R

MDC

7:688

Musculus pronator quadratus

MDC_MUSC_UPEXT_PRONATOR_QUADRAT

MDC

7:689

Musculus pronator quadratus, left

MDC_MUSC_UPEXT_PRONATOR_QUADRAT_L

MDC

7:690

Musculus pronator quadratus, right

MDC_MUSC_UPEXT_PRONATOR_QUADRAT_R

MDC

7:692

Musculus brachioradialis

MDC_MUSC_UPEXT_BRACHIORADIAL

MDC

7:693

Musculus brachioradialis, left

MDC_MUSC_UPEXT_BRACHIORADIAL_L

MDC

7:694

Musculus brachioradialis, right

MDC_MUSC_UPEXT_BRACHIORADIAL_R

MDC

7:696

Musculus extensor carpi radialis longus

MDC_MUSC_UPEXT_EXTENS_CARP_RADIAL_LONG

MDC

7:697

Musculus extensor carpi radialis longus, left

MDC_MUSC_UPEXT_EXTENS_CARP_RADIAL_LONG_L

MDC

7:698

Musculus extensor carpi radialis longus, right

MDC_MUSC_UPEXT_EXTENS_CARP_RADIAL_LONG_R

MDC

7:700

Musculus extensor carpi radialis brevis

MDC_MUSC_UPEXT_EXTENS_CARP_RADIAL_BREV

MDC

7:701

Musculus extensor carpi radialis brevis, left

MDC_MUSC_UPEXT_EXTENS_CARP_RADIAL_BREV_L

MDC

7:702

Musculus extensor carpi radialis brevis, right

MDC_MUSC_UPEXT_EXTENS_CARP_RADIAL_BREV_R

MDC

7:704

Musculus extensor digitorum

MDC_MUSC_UPEXT_EXTENS_DIGIT

MDC

7:705

Musculus extensor digitorum, left

MDC_MUSC_UPEXT_EXTENS_DIGIT_L

MDC

7:706

Musculus extensor digitorum, right

MDC_MUSC_UPEXT_EXTENS_DIGIT_R

MDC

7:708

Musculus extensor digiti minimi

MDC_MUSC_UPEXT_EXTENS_DIGIT_MIN

MDC

7:709

Musculus extensor digiti minimi, left

MDC_MUSC_UPEXT_EXTENS_DIGIT_MIN_L

MDC

7:710

Musculus extensor digiti minimi, right

MDC_MUSC_UPEXT_EXTENS_DIGIT_MIN_R

MDC

7:712

Musculus extensor carpi ulnaris

MDC_MUSC_UPEXT_EXTENS_CARP_ULNAR

MDC

7:713

Musculus extensor carpi ulnaris, left

MDC_MUSC_UPEXT_EXTENS_CARP_ULNAR_L

MDC

7:714

Musculus extensor carpi ulnaris, right

MDC_MUSC_UPEXT_EXTENS_CARP_ULNAR_R

MDC

7:716

Musculus supinator

MDC_MUSC_UPEXT_SUPINATOR

MDC

7:717

Musculus supinator, left

MDC_MUSC_UPEXT_SUPINATOR_L

MDC

7:718

Musculus supinator, right

MDC_MUSC_UPEXT_SUPINATOR_R

MDC

7:720

Musculus abductor pollicis longuss

MDC_MUSC_UPEXT_ABDUC_POLLIC_LONG

MDC

7:721

Musculus abductor pollicis longuss, left

MDC_MUSC_UPEXT_ABDUC_POLLIC_LONG_L

MDC

7:722

Musculus abductor pollicis longuss, right

MDC_MUSC_UPEXT_ABDUC_POLLIC_LONG_R

MDC

7:724

Musculus extensor pollicis brevis

MDC_MUSC_UPEXT_EXTENS_POLLIC_BREV

MDC

7:725

Musculus extensor pollicis brevis, left

MDC_MUSC_UPEXT_EXTENS_POLLIC_BREV_L

MDC

7:726

Musculus extensor pollicis brevis, right

MDC_MUSC_UPEXT_EXTENS_POLLIC_BREV_R

MDC

7:728

Musculus extensor pollicis longus

MDC_MUSC_UPEXT_EXTENS_POLLIC_LONG

MDC

7:729

Musculus extensor pollicis longus, left

MDC_MUSC_UPEXT_EXTENS_POLLIC_LONG_L

MDC

7:730

Musculus extensor pollicis longus, right

MDC_MUSC_UPEXT_EXTENS_POLLIC_LONG_R

MDC

7:732

Musculus extensor indicis

MDC_MUSC_UPEXT_EXTENS_INDIC

MDC

7:733

Musculus extensor indicis, left

MDC_MUSC_UPEXT_EXTENS_INDIC_L

MDC

7:734

Musculus extensor indicis, right

MDC_MUSC_UPEXT_EXTENS_INDIC_R

MDC

7:736

Musculus palmaris brevis

MDC_MUSC_UPEXT_PALMAR_BREV

MDC

7:737

Musculus palmaris brevis, left

MDC_MUSC_UPEXT_PALMAR_BREV_L

MDC

7:738

Musculus palmaris brevis, right

MDC_MUSC_UPEXT_PALMAR_BREV_R

MDC

7:740

Musculus abductor pollicis brevis

MDC_MUSC_UPEXT_ABDUC_POLLIC_BREV

MDC

7:741

Musculus abductor pollicis brevis, left

MDC_MUSC_UPEXT_ABDUC_POLLIC_BREV_L

MDC

7:742

Musculus abductor pollicis brevis, right

MDC_MUSC_UPEXT_ABDUC_POLLIC_BREV_R

MDC

7:744

Musculus flexor pollicis brevis

MDC_MUSC_UPEXT_FLEX_POLLIC_BREV

MDC

7:745

Musculus flexor pollicis brevis, left

MDC_MUSC_UPEXT_FLEX_POLLIC_BREV_L

MDC

7:746

Musculus flexor pollicis brevis, right

MDC_MUSC_UPEXT_FLEX_POLLIC_BREV_R

MDC

7:748

Musculus opponens pollicis

MDC_MUSC_UPEXT_OPPON_POLLIC

MDC

7:749

Musculus opponens pollicis, left

MDC_MUSC_UPEXT_OPPON_POLLIC_L

MDC

7:750

Musculus opponens pollicis, right

MDC_MUSC_UPEXT_OPPON_POLLIC_R

MDC

7:752

Musculus adductor pollicis

MDC_MUSC_UPEXT_ADDUC_POLLIC

MDC

7:753

Musculus adductor pollicis, left

MDC_MUSC_UPEXT_ADDUC_POLLIC_L

MDC

7:754

Musculus adductor pollicis, right

MDC_MUSC_UPEXT_ADDUC_POLLIC_R

MDC

7:756

Musculus abductor digiti minimi

MDC_MUSC_UPEXT_ABDUC_DIGIT_MIN

MDC

7:757

Musculus abductor digiti minimi, left

MDC_MUSC_UPEXT_ABDUC_DIGIT_MIN_L

MDC

7:758

Musculus abductor digiti minimi, right

MDC_MUSC_UPEXT_ABDUC_DIGIT_MIN_R

MDC

7:760

Musculus flexor digiti minimi brevis

MDC_MUSC_UPEXT_FLEX_DIGIT_BREV_MIN

MDC

7:761

Musculus flexor digiti minimi brevis, left

MDC_MUSC_UPEXT_FLEX_DIGIT_BREV_MIN_L

MDC

7:762

Musculus flexor digiti minimi brevis, right

MDC_MUSC_UPEXT_FLEX_DIGIT_BREV_MIN_R

MDC

7:764

Musculus opponens digiti minimi

MDC_MUSC_UPEXT_OPPON_DIGIT_MIN

MDC

7:765

Musculus opponens digiti minimi, left

MDC_MUSC_UPEXT_OPPON_DIGIT_MIN_L

MDC

7:766

Musculus opponens digiti minimi, right

MDC_MUSC_UPEXT_OPPON_DIGIT_MIN_R

MDC

7:768

Musculi lumbricales

MDC_MUSC_UPEXT_LUMBRICAL

MDC

7:769

Musculi lumbricales, left

MDC_MUSC_UPEXT_LUMBRICAL_L

MDC

7:770

Musculi lumbricales, right

MDC_MUSC_UPEXT_LUMBRICAL_R

MDC

7:772

Musculi interossei dorsales

MDC_MUSC_UPEXT_INTEROSS_DORSAL

MDC

7:773

Musculi interossei dorsales, left

MDC_MUSC_UPEXT_INTEROSS_DORSAL_L

MDC

7:774

Musculi interossei dorsales, right

MDC_MUSC_UPEXT_INTEROSS_DORSAL_R

MDC

7:776

Musculi interossei palmares

MDC_MUSC_UPEXT_INTEROSS_PALMAR

MDC

7:777

Musculi interossei palmares, left

MDC_MUSC_UPEXT_INTEROSS_PALMAR_L

MDC

7:778

Musculi interossei palmares, right

MDC_MUSC_UPEXT_INTEROSS_PALMAR_R

MDC

7:792

Musculus iliopsoas

MDC_MUSC_LOEXT_ILLIOPS

MDC

7:793

Musculus iliopsoas, left

MDC_MUSC_LOEXT_ILLIOPS_L

MDC

7:794

Musculus iliopsoas, right

MDC_MUSC_LOEXT_ILLIOPS_R

MDC

7:796

Musculus gluteus maximus

MDC_MUSC_LOEXT_GLUT_MAX

MDC

7:797

Musculus gluteus maximus, left

MDC_MUSC_LOEXT_GLUT_MAX_L

MDC

7:798

Musculus gluteus maximus, right

MDC_MUSC_LOEXT_GLUT_MAX_R

MDC

7:800

Musculus gluteus medius

MDC_MUSC_LOEXT_GLUT_MED

MDC

7:801

Musculus gluteus medius, left

MDC_MUSC_LOEXT_GLUT_MED_L

MDC

7:802

Musculus gluteus medius, right

MDC_MUSC_LOEXT_GLUT_MED_R

MDC

7:804

Musculus gluteus minimus

MDC_MUSC_LOEXT_GLUT_MIN

MDC

7:805

Musculus gluteus minimus, left

MDC_MUSC_LOEXT_GLUT_MIN_L

MDC

7:806

Musculus gluteus minimus, right

MDC_MUSC_LOEXT_GLUT_MIN_R

MDC

7:808

Musculus tensor fasciae latae

MDC_MUSC_LOEXT_TENSOR_FASC_LAT

MDC

7:809

Musculus tensor fasciae latae, left

MDC_MUSC_LOEXT_TENSOR_FASC_LAT_L

MDC

7:810

Musculus tensor fasciae latae, right

MDC_MUSC_LOEXT_TENSOR_FASC_LAT_R

MDC

7:812

Musculus piriformis

MDC_MUSC_LOEXT_PIRIFORM

MDC

7:813

Musculus piriformis, left

MDC_MUSC_LOEXT_PIRIFORM_L

MDC

7:814

Musculus piriformis, right

MDC_MUSC_LOEXT_PIRIFORM_R

MDC

7:816

Musculus obturator

MDC_MUSC_LOEXT_OBTURATOR

MDC

7:817

Musculus obturator, left

MDC_MUSC_LOEXT_OBTURATOR_L

MDC

7:818

Musculus obturator, right

MDC_MUSC_LOEXT_OBTURATOR_R

MDC

7:820

Musculus gmellus

MDC_MUSC_LOEXT_GEMEL

MDC

7:821

Musculus gmellus, left

MDC_MUSC_LOEXT_GEMEL_L

MDC

7:822

Musculus gmellus, right

MDC_MUSC_LOEXT_GEMEL_R

MDC

7:824

Musculus quadratus femoris

MDC_MUSC_LOEXT_QUADRAT_FEMOR

MDC

7:825

Musculus quadratus femoris, left

MDC_MUSC_LOEXT_QUADRAT_FEMOR_L

MDC

7:826

Musculus quadratus femoris, right

MDC_MUSC_LOEXT_QUADRAT_FEMOR_R

MDC

7:828

Musculus sartorius

MDC_MUSC_LOEXT_SARTOR

MDC

7:829

Musculus sartorius, left

MDC_MUSC_LOEXT_SARTOR_L

MDC

7:830

Musculus sartorius, right

MDC_MUSC_LOEXT_SARTOR_R

MDC

7:832

Musculus quadriceps femoris

MDC_MUSC_LOEXT_QUADRICEPS_FEMOR

MDC

7:833

Musculus quadriceps femoris, left

MDC_MUSC_LOEXT_QUADRICEPS_FEMOR_L

MDC

7:834

Musculus quadriceps femoris, right

MDC_MUSC_LOEXT_QUADRICEPS_FEMOR_R

MDC

7:836

Musculus rectus femoris

MDC_MUSC_LOEXT_RECT_FEMOR

MDC

7:837

Musculus rectus femoris, left

MDC_MUSC_LOEXT_RECT_FEMOR_L

MDC

7:838

Musculus rectus femoris, right

MDC_MUSC_LOEXT_RECT_FEMOR_R

MDC

7:840

Musculus vastus lateralis

MDC_MUSC_LOEXT_VAST_LAT

MDC

7:841

Musculus vastus lateralis, left

MDC_MUSC_LOEXT_VAST_LAT_L

MDC

7:842

Musculus vastus lateralis, right

MDC_MUSC_LOEXT_VAST_LAT_R

MDC

7:844

Musculus vastus intermedius

MDC_MUSC_LOEXT_VAST_INTERMED

MDC

7:845

Musculus vastus intermedius, left

MDC_MUSC_LOEXT_VAST_INTERMED_L

MDC

7:846

Musculus vastus intermedius, right

MDC_MUSC_LOEXT_VAST_INTERMED_R

MDC

7:848

Musculus vastus medialis

MDC_MUSC_LOEXT_VAST_MED

MDC

7:849

Musculus vastus medialis, left

MDC_MUSC_LOEXT_VAST_MED_L

MDC

7:850

Musculus vastus medialis, right

MDC_MUSC_LOEXT_VAST_MED_R

MDC

7:852

Musculus pectineus

MDC_MUSC_LOEXT_PECTIN

MDC

7:853

Musculus pectineus, left

MDC_MUSC_LOEXT_PECTIN_L

MDC

7:854

Musculus pectineus, right

MDC_MUSC_LOEXT_PECTIN_R

MDC

7:856

Musculus adductor longus

MDC_MUSC_LOEXT_ABDUC_LONG

MDC

7:857

Musculus adductor longus, left

MDC_MUSC_LOEXT_ABDUC_LONG_L

MDC

7:858

Musculus adductor longus, right

MDC_MUSC_LOEXT_ABDUC_LONG_R

MDC

7:860

Musculus adductor brevis

MDC_MUSC_LOEXT_ABDUC_BREV

MDC

7:861

Musculus adductor brevis, left

MDC_MUSC_LOEXT_ABDUC_BREV_L

MDC

7:862

Musculus adductor brevis, right

MDC_MUSC_LOEXT_ABDUC_BREV_R

MDC

7:864

Musculus adductor magnus

MDC_MUSC_LOEXT_ABDUC_MAGN

MDC

7:865

Musculus adductor magnus, left

MDC_MUSC_LOEXT_ABDUC_MAGN_L

MDC

7:866

Musculus adductor magnus, right

MDC_MUSC_LOEXT_ABDUC_MAGN_R

MDC

7:868

Musculus gracilis

MDC_MUSC_LOEXT_GRACIL

MDC

7:869

Musculus gracilis, left

MDC_MUSC_LOEXT_GRACIL_L

MDC

7:870

Musculus gracilis, right

MDC_MUSC_LOEXT_GRACIL_R

MDC

7:872

Musculus biceps femoris

MDC_MUSC_LOEXT_BICEPS_FEMOR

MDC

7:873

Musculus biceps femoris, left

MDC_MUSC_LOEXT_BICEPS_FEMOR_L

MDC

7:874

Musculus biceps femoris, right

MDC_MUSC_LOEXT_BICEPS_FEMOR_R

MDC

7:876

Musculus biceps femoris Caput longum

MDC_MUSC_LOEXT_BICEPS_FEMOR_LONG

MDC

7:877

Musculus biceps femoris Caput longum, left

MDC_MUSC_LOEXT_BICEPS_FEMOR_LONG_L

MDC

7:878

Musculus biceps femoris Caput longum, right

MDC_MUSC_LOEXT_BICEPS_FEMOR_LONG_R

MDC

7:880

Musculus biceps femoris Caput breve

MDC_MUSC_LOEXT_BICEPS_FEMOR_BREV

MDC

7:881

Musculus biceps femoris Caput breve, left

MDC_MUSC_LOEXT_BICEPS_FEMOR_BREV_L

MDC

7:882

Musculus biceps femoris Caput breve, right

MDC_MUSC_LOEXT_BICEPS_FEMOR_BREV_R

MDC

7:884

Musculus semitendinosus

MDC_MUSC_LOEXT_SEMITENDIN

MDC

7:885

Musculus semitendinosus, left

MDC_MUSC_LOEXT_SEMITENDIN_L

MDC

7:886

Musculus semitendinosus, right

MDC_MUSC_LOEXT_SEMITENDIN_R

MDC

7:888

Musculus semimembranosus

MDC_MUSC_LOEXT_SEMIMEMBRAN

MDC

7:889

Musculus semimembranosus, left

MDC_MUSC_LOEXT_SEMIMEMBRAN_L

MDC

7:890

Musculus semimembranosus, right

MDC_MUSC_LOEXT_SEMIMEMBRAN_R

MDC

7:892

Musculus tibialis anterior

MDC_MUSC_LOEXT_TIBIAL_ANT

MDC

7:893

Musculus tibialis anterior, left

MDC_MUSC_LOEXT_TIBIAL_ANT_L

MDC

7:894

Musculus tibialis anterior, right

MDC_MUSC_LOEXT_TIBIAL_ANT_R

MDC

7:896

Musculus extensor digitorum longus

MDC_MUSC_LOEXT_EXTENS_DIGIT_LONG

MDC

7:897

Musculus extensor digitorum longus, left

MDC_MUSC_LOEXT_EXTENS_DIGIT_LONG_L

MDC

7:898

Musculus extensor digitorum longus, right

MDC_MUSC_LOEXT_EXTENS_DIGIT_LONG_R

MDC

7:900

Musculus extensor hallucis longus

MDC_MUSC_LOEXT_EXTENS_HALLUC_LONG

MDC

7:901

Musculus extensor hallucis longus, left

MDC_MUSC_LOEXT_EXTENS_HALLUC_LONG_L

MDC

7:902

Musculus extensor hallucis longus, right

MDC_MUSC_LOEXT_EXTENS_HALLUC_LONG_R

MDC

7:908

Musculus peroneus longus

MDC_MUSC_LOEXT_PERON_LONG

MDC

7:909

Musculus peroneus longus, left

MDC_MUSC_LOEXT_PERON_LONG_L

MDC

7:910

Musculus peroneus longus, right

MDC_MUSC_LOEXT_PERON_LONG_R

MDC

7:912

Musculus peroneus brevis

MDC_MUSC_LOEXT_PERON_BREV

MDC

7:913

Musculus peroneus brevis, left

MDC_MUSC_LOEXT_PERON_BREV_L

MDC

7:914

Musculus peroneus brevis, right

MDC_MUSC_LOEXT_PERON_BREV_R

MDC

7:916

Musculustriceps surae

MDC_MUSC_LOEXT_TRICEPS_SUR

MDC

7:917

Musculustriceps surae, left

MDC_MUSC_LOEXT_TRICEPS_SUR_L

MDC

7:918

Musculustriceps surae, right

MDC_MUSC_LOEXT_TRICEPS_SUR_R

MDC

7:920

Musculus gastrocnemius

MDC_MUSC_LOEXT_GASTROCNEM

MDC

7:921

Musculus gastrocnemius, left

MDC_MUSC_LOEXT_GASTROCNEM_L

MDC

7:922

Musculus gastrocnemius, right

MDC_MUSC_LOEXT_GASTROCNEM_R

MDC

7:924

Musculus gastrocnemius Caput laterale

MDC_MUSC_LOEXT_GASTROCNEM_LAT

MDC

7:925

Musculus gastrocnemius Caput laterale, left

MDC_MUSC_LOEXT_GASTROCNEM_LAT_L

MDC

7:926

Musculus gastrocnemius Caput laterale, right

MDC_MUSC_LOEXT_GASTROCNEM_LAT_R

MDC

7:928

Musculus gastrocnemius Caput mediale

MDC_MUSC_LOEXT_GASTROCNEM_MED

MDC

7:929

Musculus gastrocnemius Caput mediale, left

MDC_MUSC_LOEXT_GASTROCNEM_MED_L

MDC

7:930

Musculus gastrocnemius Caput mediale, right

MDC_MUSC_LOEXT_GASTROCNEM_MED_R

MDC

7:932

Musculus soleus

MDC_MUSC_LOEXT_SOL

MDC

7:933

Musculus soleus, left

MDC_MUSC_LOEXT_SOL_L

MDC

7:934

Musculus soleus, right

MDC_MUSC_LOEXT_SOL_R

MDC

7:936

Musculus plantaris

MDC_MUSC_LOEXT_PLANTAR

MDC

7:937

Musculus plantaris, left

MDC_MUSC_LOEXT_PLANTAR_L

MDC

7:938

Musculus plantaris, right

MDC_MUSC_LOEXT_PLANTAR_R

MDC

7:940

Musculus popliteus

MDC_MUSC_LOEXT_POPLIT

MDC

7:941

Musculus popliteus, left

MDC_MUSC_LOEXT_POPLIT_L

MDC

7:942

Musculus popliteus, right

MDC_MUSC_LOEXT_POPLIT_R

MDC

7:944

Musculus tibialis posterior

MDC_MUSC_LOEXT_TIBIAL_POST

MDC

7:945

Musculus tibialis posterior, left

MDC_MUSC_LOEXT_TIBIAL_POST_L

MDC

7:946

Musculus tibialis posterior, right

MDC_MUSC_LOEXT_TIBIAL_POST_R

MDC

7:948

Musculus flexor digitorum longus

MDC_MUSC_LOEXT_FLEX_DIGIT_LONG

MDC

7:949

Musculus flexor digitorum longus, left

MDC_MUSC_LOEXT_FLEX_DIGIT_LONG_L

MDC

7:950

Musculus flexor digitorum longus, right

MDC_MUSC_LOEXT_FLEX_DIGIT_LONG_R

MDC

7:952

Musculus extensor hallucis brevis

MDC_MUSC_LOEXT_EXTENS_HALLUC_BREV

MDC

7:953

Musculus extensor hallucis brevis, left

MDC_MUSC_LOEXT_EXTENS_HALLUC_BREV_L

MDC

7:954

Musculus extensor hallucis brevis, right

MDC_MUSC_LOEXT_EXTENS_HALLUC_BREV_R

MDC

7:956

Musculus extensor digitorum brevis

MDC_MUSC_LOEXT_EXTENS_DIGIT_BREV

MDC

7:957

Musculus extensor digitorum brevis, left

MDC_MUSC_LOEXT_EXTENS_DIGIT_BREV_L

MDC

7:958

Musculus extensor digitorum brevis, right

MDC_MUSC_LOEXT_EXTENS_DIGIT_BREV_R

MDC

7:960

Musculus abductor hallucis

MDC_MUSC_LOEXT_ABDUC_HALLUC

MDC

7:961

Musculus abductor hallucis, left

MDC_MUSC_LOEXT_ABDUC_HALLUC_L

MDC

7:962

Musculus abductor hallucis, right

MDC_MUSC_LOEXT_ABDUC_HALLUC_R

MDC

7:964

Musculus flexor hallucis brevis

MDC_MUSC_LOEXT_FLEX_HALLUC_BREV

MDC

7:965

Musculus flexor hallucis brevis, left

MDC_MUSC_LOEXT_FLEX_HALLUC_BREV_L

MDC

7:966

Musculus flexor hallucis brevis, right

MDC_MUSC_LOEXT_FLEX_HALLUC_BREV_R

MDC

7:968

Musculus adductor hallucis

MDC_MUSC_LOEXT_ADDUC_HALLUC

MDC

7:969

Musculus adductor hallucis, left

MDC_MUSC_LOEXT_ADDUC_HALLUC_L

MDC

7:970

Musculus adductor hallucis

MDC_MUSC_LOEXT_ADDUC_HALLUC_R

MDC

7:972

Musculus abductor digiti minimi

MDC_MUSC_LOEXT_ABDUC_DIGIT_MIN

MDC

7:973

Musculus abductor digiti minimi, left

MDC_MUSC_LOEXT_ABDUC_DIGIT_MIN_L

MDC

7:974

Musculus abductor digiti minimi

MDC_MUSC_LOEXT_ABDUC_DIGIT_MIN_R

MDC

7:976

Musculus flexor digiti minimi brevis

MDC_MUSC_LOEXT_FLEX_DIGIT_BREV_MIN

MDC

7:977

Musculus flexor digiti minimi brevis, left

MDC_MUSC_LOEXT_FLEX_DIGIT_BREV_MIN_L

MDC

7:978

Musculus flexor digiti minimi brevis, right

MDC_MUSC_LOEXT_FLEX_DIGIT_BREV_MIN_R

MDC

7:980

Musculus quadratus plantae

MDC_MUSC_LOEXT_QUADRAT_PLANT

MDC

7:981

Musculus quadratus plantae, left

MDC_MUSC_LOEXT_QUADRAT_PLANT_L

MDC

7:982

Musculus quadratus plantae, right

MDC_MUSC_LOEXT_QUADRAT_PLANT_R

MDC

7:984

Musculi lunbricales

MDC_MUSC_LOEXT_LUMBRICAL

MDC

7:985

Musculi lunbricales, left

MDC_MUSC_LOEXT_LUMBRICAL_L

MDC

7:986

Musculi lunbricales, right

MDC_MUSC_LOEXT_LUMBRICAL_R

MDC

7:988

Musculus interossei dorsales

MDC_MUSC_LOEXT_INTEROSS_DORSAL

MDC

7:989

Musculus interossei dorsales, left

MDC_MUSC_LOEXT_INTEROSS_DORSAL_L

MDC

7:990

Musculus interossei dorsales, right

MDC_MUSC_LOEXT_INTEROSS_DORSAL_R

MDC

7:992

Musculus interossei plantares

MDC_MUSC_LOEXT_INTEROSS_PLANTAR

MDC

7:993

Musculus interossei plantares, left

MDC_MUSC_LOEXT_INTEROSS_PLANTAR_L

MDC

7:994

Musculus interossei plantares, right

MDC_MUSC_LOEXT_INTEROSS_PLANTAR_R


DICOM PS3.16 2026b - Content Mapping Resource