DICOM PS3.16 2026d - Content Mapping Resource

CID 3001 ECG Lead

This Context Group comprises the ECG lead identifiers of ISO/IEEE 11073-10101, including human and canine leads. The terms included in the table below may not constitute the complete list; see the ISO/IEEE Standard.

Note

Codes reprinted by permission of IEEE, Copyright 2004 by IEEE. ISO/IEEE 11073-10101 available through http://standards.ieee.org.

Resources:

HTML | FHIR JSON | FHIR XML | IHE SVS XML

Keyword:

ECGLead

FHIR Keyword:

dicom-cid-3001-ECGLead

Type:

Extensible

Version:

20130613

UID:

1.2.840.10008.6.1.43

Table CID 3001. ECG Lead

Coding Scheme Designator

Code Value

Code Meaning

ISO/IEEE 11073 MDC Equivalent Reference ID (Informative)

MDC

2:71

Lead A (Nehb - Anterior)

MDC_ECG_LEAD_A

MDC

2:75

Auxiliary unipolar lead 1

MDC_ECG_LEAD_A1

MDC

2:76

Auxiliary unipolar lead 2

MDC_ECG_LEAD_A2

MDC

2:77

Auxiliary unipolar lead 3

MDC_ECG_LEAD_A3

MDC

2:78

Auxiliary unipolar lead 4

MDC_ECG_LEAD_A4

MDC

2:127

Auxiliary bipolar lead 1

MDC_ECG_LEAD_AB1

MDC

2:128

Auxiliary bipolar lead 2

MDC_ECG_LEAD_AB2

MDC

2:129

Auxiliary bipolar lead 3

MDC_ECG_LEAD_AB3

MDC

2:130

Auxiliary bipolar lead 4

MDC_ECG_LEAD_AB4

MDC

2:133

EASI Lead AI

MDC_ECG_LEAD_AI

MDC

2:132

EASI Lead AS

MDC_ECG_LEAD_AS

MDC

2:64

aVF, augmented voltage, foot

MDC_ECG_LEAD_AVF

MDC

2:63

aVL, augmented voltage, left

MDC_ECG_LEAD_AVL

MDC

2:62

aVR, augmented voltage, right

MDC_ECG_LEAD_AVR

MDC

2:65

−aVR

MDC_ECG_LEAD_AVRneg

MDC

2:86

Chest lead

MDC_ECG_LEAD_C

MDC

2:124

negative: low right scapula Lead

MDC_ECG_LEAD_CB5

MDC

2:98

Chest lead (symmetric placement)

MDC_ECG_LEAD_CC

MDC

2:99

Chest lead per V1 and V1R placement

MDC_ECG_LEAD_CC1

MDC

2:100

Chest lead per V2 and V2R placement

MDC_ECG_LEAD_CC2

MDC

2:101

Chest lead per V3 and V3R placement

MDC_ECG_LEAD_CC3

MDC

2:102

Chest lead per V4 and V4R placement

MDC_ECG_LEAD_CC4

MDC

2:19

Chest lead per V5 and V5R placement

MDC_ECG_LEAD_CC5

MDC

2:103

Chest lead per V6 and V6R placement

MDC_ECG_LEAD_CC6

MDC

2:104

Chest lead per V7 and V8R placement

MDC_ECG_LEAD_CC7

MDC

2:122

Lead CH5

MDC_ECG_LEAD_CH5

MDC

2:105

Chest-manubrium lead

MDC_ECG_LEAD_CM

MDC

2:106

Chest-manubrium lead per V1 placement

MDC_ECG_LEAD_CM1

MDC

2:107

Chest-manubrium lead per V2 placement

MDC_ECG_LEAD_CM2

MDC

2:108

Chest-manubrium lead per V3 placement

MDC_ECG_LEAD_CM3

MDC

2:109

Chest-manubrium lead per V4 placement

MDC_ECG_LEAD_CM4

MDC

2:20

Chest-manubrium lead per V5 placement

MDC_ECG_LEAD_CM5

MDC

2:110

Chest-manubrium lead per V6 placement

MDC_ECG_LEAD_CM6

MDC

2:121

Chest-manubrium lead per V7 placement

MDC_ECG_LEAD_CM7

MDC

2:125

Lead CR5

MDC_ECG_LEAD_CR5

MDC

2:123

negative: right infraclavicular fossa

MDC_ECG_LEAD_CS5

MDC

2:148

Canine, fifth right intercostal space near edge of sternum

MDC_ECG_LEAD_CV5RL

MDC

2:149

Canine, sixth left intercostal space near edge of sternum

MDC_ECG_LEAD_CV6LL

MDC

2:150

Canine, sixth left intercostal space at costochondral junction

MDC_ECG_LEAD_CV6LU

MDC

2:70

Lead D (Nehb - Dorsal)

MDC_ECG_LEAD_D

MDC

2:114

Derived Lead aVF

MDC_ECG_LEAD_dAVF

MDC

2:113

Derived Lead aVL

MDC_ECG_LEAD_dAVL

MDC

2:112

Derived Lead aVR

MDC_ECG_LEAD_dAVR

MDC

2:73

Defibrillator lead: anterior-lateral

MDC_ECG_LEAD_DEFIB

MDC

2:31

Derived Lead I

MDC_ECG_LEAD_dI

MDC

2:32

Derived Lead II

MDC_ECG_LEAD_dII

MDC

2:111

Derived Lead III

MDC_ECG_LEAD_dIII

MDC

2:33

Derived Lead V1

MDC_ECG_LEAD_dV1

MDC

2:34

Derived Lead V2

MDC_ECG_LEAD_dV2

MDC

2:35

Derived Lead V3

MDC_ECG_LEAD_dV3

MDC

2:36

Derived Lead V4

MDC_ECG_LEAD_dV4

MDC

2:37

Derived Lead V5

MDC_ECG_LEAD_dV5

MDC

2:38

Derived Lead V6

MDC_ECG_LEAD_dV6

MDC

2:131

EASI Lead ES

MDC_ECG_LEAD_ES

MDC

2:74

External pacing lead: anterior-posterior

MDC_ECG_LEAD_EXTERN

MDC

2:27

Frank Lead A

MDC_ECG_LEAD_fA

MDC

2:26

Frank Lead C

MDC_ECG_LEAD_fC

MDC

2:25

Frank Lead E

MDC_ECG_LEAD_fE

MDC

2:29

Frank Lead F

MDC_ECG_LEAD_fF

MDC

2:30

Frank Lead H

MDC_ECG_LEAD_fH

MDC

2:24

Frank Lead I

MDC_ECG_LEAD_fI

MDC

2:28

Frank Lead M

MDC_ECG_LEAD_fM

MDC

2:1

Lead I

MDC_ECG_LEAD_I

MDC

2:2

Lead II

MDC_ECG_LEAD_II

MDC

2:61

Lead III

MDC_ECG_LEAD_III

MDC

2:72

Lead J (Nehb - Inferior)

MDC_ECG_LEAD_J

MDC

2:21

Left Arm Lead

MDC_ECG_LEAD_LA

MDC

2:23

Left Leg Lead

MDC_ECG_LEAD_LL

MDC

2:91

Modified chest lead (left arm indifferent)

MDC_ECG_LEAD_MCL

MDC

2:92

Modified chest lead per V1 placement

MDC_ECG_LEAD_MCL1

MDC

2:93

Modified chest lead per V2 placement

MDC_ECG_LEAD_MCL2

MDC

2:94

Modified chest lead per V3 placement

MDC_ECG_LEAD_MCL3

MDC

2:95

Modified chest lead per V4 placement

MDC_ECG_LEAD_MCL4

MDC

2:96

Modified chest lead per V5 placement

MDC_ECG_LEAD_MCL5

MDC

2:97

Modified chest lead per V6 placement

MDC_ECG_LEAD_MCL6

MDC

2:126

Modified limb lead

MDC_ECG_LEAD_ML

MDC

2:22

Right Arm Lead

MDC_ECG_LEAD_RA

MDC

2:147

Right Leg Lead

MDC_ECG_LEAD_RL

MDC

2:134

EASI upper sternum lead

MDC_ECG_LEAD_S

MDC

2:87

Precordial lead

MDC_ECG_LEAD_V

MDC

2:3

Lead V1

MDC_ECG_LEAD_V1

MDC

2:151

Canine, over dorsal spinous process of 7th thoracic vertebra

MDC_ECG_LEAD_V10

MDC

2:4

Lead V2

MDC_ECG_LEAD_V2

MDC

2:10

Lead V2R

MDC_ECG_LEAD_V2R

MDC

2:5

Lead V3

MDC_ECG_LEAD_V3

MDC

2:11

Lead V3R

MDC_ECG_LEAD_V3R

MDC

2:6

Lead V4

MDC_ECG_LEAD_V4

MDC

2:12

Lead V4R

MDC_ECG_LEAD_V4R

MDC

2:7

Lead V5

MDC_ECG_LEAD_V5

MDC

2:13

Lead V5R

MDC_ECG_LEAD_V5R

MDC

2:8

Lead V6

MDC_ECG_LEAD_V6

MDC

2:14

Lead V6R

MDC_ECG_LEAD_V6R

MDC

2:9

Lead V7

MDC_ECG_LEAD_V7

MDC

2:15

Lead V7R

MDC_ECG_LEAD_V7R

MDC

2:66

Lead V8

MDC_ECG_LEAD_V8

MDC

2:68

Lead V8R

MDC_ECG_LEAD_V8R

MDC

2:67

Lead V9

MDC_ECG_LEAD_V9

MDC

2:69

Lead V9R

MDC_ECG_LEAD_V9R

MDC

2:90

Lead VF, nonaugmented voltage, vector of LL

MDC_ECG_LEAD_VF

MDC

2:89

Lead VL, nonaugmented voltage, vector of LA

MDC_ECG_LEAD_VL

MDC

2:88

Lead VR, nonaugmented voltage, vector of RA

MDC_ECG_LEAD_VR

MDC

2:16

Lead X

MDC_ECG_LEAD_X

MDC

2:17

Lead Y

MDC_ECG_LEAD_Y

MDC

2:18

Lead Z

MDC_ECG_LEAD_Z

MDC

2:0

Unspecified lead

MDC_ECG_LEAD_CONFIG


Note

  1. A prior version of this Context Group used codes from the SCP-ECG vocabulary.

  2. In a prior version of this table, the code 2:26 was specified for the concept Chest lead and the code 2:19 was specified for the concept Chest-manubrium lead per V5 placement.