DICOM PS3.16 2026b - Content Mapping Resource

CID 29 Acquisition Modality

This Context Group includes codes that may be used to identify the type of diagnostic equipment, or function or technique of that equipment, that originally acquired, through interaction with a patient or specimen, the data used to create the instance. These codes are used in Modality (0008,0060) of a Modality Worklist Scheduled Procedure Step or a Composite SOP Instance (see PS3.3). It generally corresponds to a class of diagnostic equipment, or to a specific acquisition function or technique in a device. This Context Group may be used as the value set for HL7 v2 Table 0259 (see HL7 v2.6 Chapter 8 Section 8.8.8.47).

Note

This Context Group is not the complete set of codes that may appear in Modality (0008,0060); these are only the codes associated with orderable acquisition processes (not pre-acquisition activities or post-processing).

Resources:

HTML | FHIR JSON | FHIR XML | IHE SVS XML

Keyword:

AcquisitionModality

FHIR Keyword:

dicom-cid-29-AcquisitionModality

Type:

Extensible

Version:

20231115

UID:

1.2.840.10008.6.1.19

Table CID 29. Acquisition Modality

Coding Scheme Designator

Code Value

Code Meaning

DCM

AR

Autorefraction

DCM

BI

Biomagnetic Imaging

DCM

BMD

Bone Mineral Densitometry

DCM

CR

Computed Radiography

DCM

CT

Computed Tomography

DCM

CFM

Confocal Microscopy

DCM

DMS

Dermoscopy

DCM

DG

Diaphanography

DCM

DX

Digital Radiography

DCM

ES

Endoscopy

DCM

XC

External-camera Photography

DCM

GM

General Microscopy

DCM

IO

Intra-oral Radiography

DCM

IVOCT

Intravascular Optical Coherence Tomography

DCM

IVUS

Intravascular Ultrasound

DCM

KER

Keratometry

DCM

LS

Laser surface scan

DCM

LEN

Lensometry

DCM

MR

Magnetic Resonance

DCM

MG

Mammography

DCM

NM

Nuclear Medicine

DCM

OAM

Ophthalmic Axial Measurements

DCM

OPM

Ophthalmic Mapping

DCM

OP

Ophthalmic Photography

DCM

OPT

Ophthalmic Tomography

DCM

OPTBSV

Ophthalmic Tomography B-scan Volume Analysis

DCM

OPTENF

Ophthalmic Tomography En Face

DCM

OPV

Ophthalmic Visual Field

DCM

OCT

Optical Coherence Tomography

DCM

OSS

Optical Surface Scanner

DCM

PX

Panoramic X-Ray

DCM

PA

Photoacoustic

DCM

PT

Positron emission tomography

DCM

RF

Radiofluoroscopy

DCM

RG

Radiographic imaging

DCM

RTIMAGE

RT Image

DCM

SM

Slide Microscopy

DCM

SRF

Subjective Refraction

DCM

TG

Thermography

DCM

US

Ultrasound

DCM

BDUS

Ultrasound Bone Densitometry

DCM

VA

Visual Acuity

DCM

XA

X-Ray Angiography

Include CID 34 “Waveform Acquisition Modality”


DICOM PS3.16 2026b - Content Mapping Resource